WorldWideScience

Sample records for quantitative needle electromyography

  1. Quantitative electromyography in ambulatory boys with Duchenne muscular dystrophy.

    Science.gov (United States)

    Verma, Sumit; Lin, Jenny; Travers, Curtis; McCracken, Courtney; Shah, Durga

    2017-12-01

    This study's objective was to evaluate quantitative electromyography (QEMG) using multiple-motor-unit (multi-MUP) analysis in Duchenne muscular dystrophy (DMD). Ambulatory DMD boys, aged 5-15 years, were evaluated with QEMG at 6-month intervals over 14 months. EMG was performed in the right biceps brachii (BB) and tibialis anterior (TA) muscles. Normative QEMG data were obtained from age-matched healthy boys. Wilcoxon signed-rank tests were performed. Eighteen DMD subjects were enrolled, with a median age of 7 (interquartile range 7-10) years. Six-month evaluations were performed on 14 subjects. QEMG showed significantly abnormal mean MUP duration in BB and TA muscles, with no significant change over 6 months. QEMG is a sensitive electrophysiological marker of myopathy in DMD. Preliminary data do not reflect a significant change in MUP parameters over a 6-month interval; long-term follow-up QEMG studies are needed to understand its role as a biomarker for disease progression. Muscle Nerve 56: 1361-1364, 2017. © 2017 Wiley Periodicals, Inc.

  2. Quantitative estimation of muscle fatigue using surface electromyography during static muscle contraction.

    Science.gov (United States)

    Soo, Yewguan; Sugi, Masao; Nishino, Masataka; Yokoi, Hiroshi; Arai, Tamio; Kato, Ryu; Nakamura, Tatsuhiro; Ota, Jun

    2009-01-01

    Muscle fatigue is commonly associated with the musculoskeletal disorder problem. Previously, various techniques were proposed to index the muscle fatigue from electromyography signal. However, quantitative measurement is still difficult to achieve. This study aimed at proposing a method to estimate the degree of muscle fatigue quantitatively. A fatigue model was first constructed using handgrip dynamometer by conducting a series of static contraction tasks. Then the degree muscle fatigue can be estimated from electromyography signal with reasonable accuracy. The error of the estimated muscle fatigue was less than 10% MVC and no significant difference was found between the estimated value and the one measured using force sensor. Although the results were promising, there were still some limitations that need to be overcome in future study.

  3. Paracetamol 325 mg/tramadol 37.5 mg effect on pain during needle electromyography: a double-blind crossover clinical trial.

    Science.gov (United States)

    Kalantar, Seyed Sadeq; Abbasi, Mehrshad; Faghihi-Kashani, Sara; Majedi, Hossein; Ahmadi, Mona; Agah, Elmira; Tafakhori, Abbas

    2016-12-01

    Needle insertion during electromyography (EMG) may cause varying levels of pain that could lead to inaccurate assessment and premature termination of the procedure. The aim of this study is to compare paracetamol 325 mg/tramadol 37.5 mg with placebo in relieving pain before EMG. This is a randomized, crossover, placebo-controlled, double-blind clinical trial; forty-four healthy individuals, including 27 males with a mean age of 35.3 years (range 18-59 years), entered this study. The needles were inserted unilaterally 2 h after administration of two analgesic tablets of paracetamol 325 mg/tramadol 37.5 mg or two placebo tablets. The pain was scored through a 100-mm visual analog scale (VAS) immediately and 2 h after the procedure. The side effects were also recorded. Within a week, the procedure was repeated on the other upper limb, changing the treatment and placebo. The immediate and 2-h VAS scores were notably lower after administration of treatment compared to placebo (immediate pain: 17.5 ± 12.8 vs. 32.1 ± 16.0, P pain: 1.6 ± 5.6 vs. 5.8 ± 7.9, P = 0. 002). There was a higher prevalence of side effects when treatment was used (48 vs. 9 %, P pain. Further application of this medication in patients with neuromuscular disorders would warrant additional clinical trials, particularly considering the adverse events.

  4. Quantitative analysis of fine needle aspiration biopsy samples

    International Nuclear Information System (INIS)

    Rajer, M.; Kmet, M.

    2005-01-01

    Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures. Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk's chamber was used for this purpose. Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%). Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures. (author)

  5. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  7. Muscle-fiber conduction velocity and electromyography as diagnostic tools in patients with suspected inflammatory myopathy: a prospective study.

    NARCIS (Netherlands)

    Blijham, P.J.; Hengstman, G.J.D.; Laak, H.J. ter; Engelen, B.G.M. van; Zwarts, M.J.

    2004-01-01

    Combinations of different techniques can increase the diagnostic yield from neurophysiological examination of muscle. In 25 patients with suspected inflammatory myopathy, we prospectively performed needle electromyography (EMG) and measured muscle-fiber conduction velocity (MFCV) in a single muscle,

  8. Quantitative Proteomic Analysis of Optimal Cutting Temperature (OCT) Embedded Core-Needle Biopsy of Lung Cancer

    Science.gov (United States)

    Zhao, Xiaozheng; Huffman, Kenneth E.; Fujimoto, Junya; Canales, Jamie Rodriguez; Girard, Luc; Nie, Guangjun; Heymach, John V.; Wistuba, Igacio I.; Minna, John D.; Yu, Yonghao

    2017-10-01

    With recent advances in understanding the genomic underpinnings and oncogenic drivers of pathogenesis in different subtypes, it is increasingly clear that proper pretreatment diagnostics are essential for the choice of appropriate treatment options for non-small cell lung cancer (NSCLC). Tumor tissue preservation in optimal cutting temperature (OCT) compound is commonly used in the surgical suite. However, proteins recovered from OCT-embedded specimens pose a challenge for LC-MS/MS experiments, due to the large amounts of polymers present in OCT. Here we present a simple workflow for whole proteome analysis of OCT-embedded NSCLC tissue samples, which involves a simple trichloroacetic acid precipitation step. Comparisons of protein recovery between frozen versus OCT-embedded tissue showed excellent consistency with more than 9200 proteins identified. Using an isobaric labeling strategy, we quantified more than 5400 proteins in tumor versus normal OCT-embedded core needle biopsy samples. Gene ontology analysis indicated that a number of proliferative as well as squamous cell carcinoma (SqCC) marker proteins were overexpressed in the tumor, consistent with the patient's pathology based diagnosis of "poorly differentiated SqCC". Among the most downregulated proteins in the tumor sample, we noted a number of proteins with potential immunomodulatory functions. Finally, interrogation of the aberrantly expressed proteins using a candidate approach and cross-referencing with publicly available databases led to the identification of potential druggable targets in DNA replication and DNA damage repair pathways. We conclude that our approach allows LC-MS/MS proteomic analyses on OCT-embedded lung cancer specimens, opening the way to bring powerful proteomics into the clinic. [Figure not available: see fulltext.

  9. Surface electromyography physiology, engineering and applications

    CERN Document Server

    Farina, Dario

    2016-01-01

    The book presents a quantitative approach to the study and use of noninvasively detected electromyographic (EMG) signals, as well as their numerous applications in various aspects of the life sciences. Surface Electromyography: Physiology, Engineering, and Applications is an update of Electromyography: Physiology, Engineering, and Noninvasive Applications (Wiley-IEEE Press, 2004) and focuses on the developments that have taken place over the last decade. The first nine chapters deal with the generation, detection, understanding, interpretation, and modeling of EMG signals. Detection technology, with particular focus on EMG imaging techniques that are based on two-dimensional electrode arrays are also included in the first half of the book. The latter 11 chapters deal with applications, which range fro monitoring muscle fatigue, electrically elicited contractions, posture analysis, prevention of work-related and child-delivery-related neuromuscular disorders, ergonomics, movement analysis, physical therapy, ex...

  10. The essential oil qualitative and quantitative composition in the needles of Pinus sylvestris L. growing along industrial transects

    Energy Technology Data Exchange (ETDEWEB)

    Kupcinskiene, Eugenija [Department of Biology, Vytautas Magnus University, Vileikos 8, LT-44404 Kaunas (Lithuania)], E-mail: e.kupcinskiene@gmail.com; Stikliene, Aida [Department of Ecology, Lithuanian University of Agriculture, Studentu 11, LT-53361 Kaunas, Akademija (Lithuania); Judzentiene, Asta [Institute of Chemistry, A. Gostauto 9, LT-01108 Vilnius (Lithuania)

    2008-10-15

    The aim of this study was to evaluate composition of the essential oils in the needles of Pinus sylvestris growing in the areas affected by a cement factory (CF), and an oil refinery (OR). Volatile components of the needles were analyzed by GC and GC/MS. The most heavily polluted CF stand had significantly higher concentration of {gamma}-Terpinene, Caryophyllene oxide in the current-year needles, while higher concentration of {delta}-3-Carene, {alpha}-Terpinene, {gamma}-Terpinene and Terpinolene was documented for 1-year-old needles. The most heavily polluted OR stand had a significantly higher concentration of Sabinene + {beta}-Pinene, 1-epi-Cubenol in the current-year needles and a significantly higher concentration of Camphene, Sabinene + {beta}-Pinene, Myrcene, {alpha}-Cadinene, 1-epi-Cubenol in the 1-year-old needles than the least polluted site. Along transects an increase in the amount of some diterpenes and a decrease in the components of the shorter chain essential oils was observed. These effects could be at least partially attributed to SO{sub 2}. - Quantities of components of essential oil in the needles of Scots pine growing around two factories are described in relation to pollution.

  11. The essential oil qualitative and quantitative composition in the needles of Pinus sylvestris L. growing along industrial transects

    International Nuclear Information System (INIS)

    Kupcinskiene, Eugenija; Stikliene, Aida; Judzentiene, Asta

    2008-01-01

    The aim of this study was to evaluate composition of the essential oils in the needles of Pinus sylvestris growing in the areas affected by a cement factory (CF), and an oil refinery (OR). Volatile components of the needles were analyzed by GC and GC/MS. The most heavily polluted CF stand had significantly higher concentration of γ-Terpinene, Caryophyllene oxide in the current-year needles, while higher concentration of δ-3-Carene, α-Terpinene, γ-Terpinene and Terpinolene was documented for 1-year-old needles. The most heavily polluted OR stand had a significantly higher concentration of Sabinene + β-Pinene, 1-epi-Cubenol in the current-year needles and a significantly higher concentration of Camphene, Sabinene + β-Pinene, Myrcene, α-Cadinene, 1-epi-Cubenol in the 1-year-old needles than the least polluted site. Along transects an increase in the amount of some diterpenes and a decrease in the components of the shorter chain essential oils was observed. These effects could be at least partially attributed to SO 2 . - Quantities of components of essential oil in the needles of Scots pine growing around two factories are described in relation to pollution

  12. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  13. The essential oil qualitative and quantitative composition in the needles of Pinus sylvestris L. growing along industrial transects.

    Science.gov (United States)

    Kupcinskiene, Eugenija; Stikliene, Aida; Judzentiene, Asta

    2008-10-01

    The aim of this study was to evaluate composition of the essential oils in the needles of Pinus sylvestris growing in the areas affected by a cement factory (CF), and an oil refinery (OR). Volatile components of the needles were analyzed by GC and GC/MS. The most heavily polluted CF stand had significantly higher concentration of gamma-Terpinene, Caryophyllene oxide in the current-year needles, while higher concentration of delta-3-Carene, alpha-Terpinene, gamma-Terpinene and Terpinolene was documented for 1-year-old needles. The most heavily polluted OR stand had a significantly higher concentration of Sabinene+beta-Pinene, 1-epi-Cubenol in the current-year needles and a significantly higher concentration of Camphene, Sabinene+beta-Pinene, Myrcene, alpha-Cadinene, 1-epi-Cubenol in the 1-year-old needles than the least polluted site. Along transects an increase in the amount of some diterpenes and a decrease in the components of the shorter chain essential oils was observed. These effects could be at least partially attributed to SO(2).

  14. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  15. Concentric needle single fiber electromyography: normative jitter values on voluntary activated Extensor Digitorum Communis Eletromiografia de fibra única com agulha concêntrica: valores normativos do jitter no estudo por contração voluntária do músculo Extensor Digitorum Communis

    Directory of Open Access Journals (Sweden)

    João Aris Kouyoumdjian

    2007-06-01

    Full Text Available Single fiber electromyography (SFEMG is the most sensitive clinical neurophysiological test for neuromuscular junction disorders, particularly myasthenia gravis. Normal values for jitter obtained with SFEMG electrode have been published, but there are few publications for concentric needle electrode (CNE. The aim of this study was to discuss the possibilities to analyse the jitter in CNE recordings and to get normal values of jitter for voluntary activated Extensor Digitorum Communis using disposable CNE. Fifty normal subjects were studied, 16 male and 34 female with a mean age of 37.1±10.3 years (19-55. The jitter values of action potentials pairs of isolated muscular fibers were expressed as the mean consecutive difference (MCD after 20 analysed potential pairs. The mean MCD (n=50 obtained was 24.2±2.8 µs (range of mean values in each subject was 18-31. Upper 95% confidence limit is 29.8 µs. The mean jitter of all potential pairs (n=1000 obtained was 24.07±7.30 µs (range 9-57. A practical upper limit for individual data is set to 46 µs. The mean interpotential interval (MIPI was 779±177 µs (range of individual mean values was 530-1412; there were no potentials with impulse blocking. The present study confirms that CNE is suitable for jitter analysis although certain precautions must be mentioned. Our findings of jitter values with CNE were similar to some other few reports in literature.Eletromiografia de fibra única (SFEMG é o método eletrofisiológico mais sensível para diagnóstico das desordens de junção neuromuscular, particularmente miastenia gravis. Jitter obtido por meio de eletrodo de SFEMG já foi padronizado, porém há poucas publicações com uso de eletrodo de agulha concêntrica (CNE. O objetivo deste estudo é discutir as possibilidades de analisar o jitter por registro com CNE e obter valores normativos para o músculo Extensor Digitorum Communis por ativação muscular mínima. Foram estudados 50 indiv

  16. Electromyography

    Science.gov (United States)

    ... problem affecting the median nerve in the arm) Duchenne muscular dystrophy (inherited disease that involves muscle weakness) Facioscapulohumeral muscular dystrophy (Landouzy-Dejerine; disease of ...

  17. Electromyography physiology engineering and noninvasive applications

    CERN Document Server

    Parker, Philip; John Wiley & Sons

    2004-01-01

    "Featuring contributions from key innovators working in the field today, Electromyography reveals the broad applications of EMG data in areas as diverse as neurology, ergonomics, exercise physiology, rehabilitation, movement analysis, biofeedback, and myoelectric control of prostheses." "Electromyography offers physiologists, medical professionals, and students in biomedical engineering a new window into the possibilities of this technology."--Jacket.

  18. Laryngeal electromyography in movement disorders: preliminary data

    Directory of Open Access Journals (Sweden)

    Kimaid Paulo A.T.

    2004-01-01

    Full Text Available This study describes preliminary laryngeal electromyography (LEMG data and botulinum toxin treatment in patients with dysphonia due to movement disorders. Twenty-five patients who had been clinically selected for botulinum toxin administration were examined, 19 with suspected laryngeal dystonia or spasmodic dysphonia (SD, 5 with vocal tremor, and 1 with Gilles de la Tourette syndrome (GTS. LEMG evaluations were performed before botulinum toxin administration using monopolar electrodes. Electromyography was consistent with dystonia in 14 patients and normal in 5, and differences in frequency suggesting essential tremor in 3 and Parkinson tremors in 2. The different LEMG patterns and significant improvement in our patients from botulinum toxin therapy has led us to perform laryngeal electromyography as a routine in UNICAMP movement disorders ambulatory.

  19. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  20. Entropic Analysis of Electromyography Time Series

    Science.gov (United States)

    Kaufman, Miron; Sung, Paul

    2005-03-01

    We are in the process of assessing the effectiveness of fractal and entropic measures for the diagnostic of low back pain from surface electromyography (EMG) time series. Surface electromyography (EMG) is used to assess patients with low back pain. In a typical EMG measurement, the voltage is measured every millisecond. We observed back muscle fatiguing during one minute, which results in a time series with 60,000 entries. We characterize the complexity of time series by computing the Shannon entropy time dependence. The analysis of the time series from different relevant muscles from healthy and low back pain (LBP) individuals provides evidence that the level of variability of back muscle activities is much larger for healthy individuals than for individuals with LBP. In general the time dependence of the entropy shows a crossover from a diffusive regime to a regime characterized by long time correlations (self organization) at about 0.01s.

  1. Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.

    Science.gov (United States)

    Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice

    2016-02-01

    Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.

  2. A cross-sectional electromyography assessment in linear scleroderma patients

    Science.gov (United States)

    2014-01-01

    Background Muscle atrophy and asymmetric extremity growth is a common feature of linear scleroderma (LS). Extra-cutaneous features are also common and primary neurologic involvement, with sympathetic dysfunction, may have a pathogenic role in subcutaneous and muscle atrophy. The aim was investigate nerve conduction and muscle involvement by electromyography in pediatric patients with LS. Methods We conducted a retrospective review of LS pediatric patients who had regular follow up at a single pediatric center from 1997–2013. We selected participants if they had consistently good follow up and enrolled consecutive patients in the study. We examined LS photos as well as clinical, serological and imaging findings. Electromyograms (EMG) were performed with bilateral symmetric technique, using surface and needle electrodes, comparing the affected side with the contralateral side. Abnormal muscle activity was categorized as a myopathic or neurogenic pattern. Results Nine LS subjects were selected for EMG, 2 with Parry-Romberg/Hemifacial Atrophy Syndrome, 7 linear scleroderma of an extremity and 2 with mixed forms (linear and morphea). Electromyogram analysis indicated that all but one had asymmetric myopathic pattern in muscles underlying the linear streaks. Motor and sensory nerve conduction was also evaluated in upper and lower limbs and one presented a neurogenic pattern. Masticatory muscle testing showed a myopathic pattern in the atrophic face of 2 cases with head and face involvement. Conclusion In our small series of LS patients, we found a surprising amount of muscle dysfunction by EMG. The muscle involvement may be possibly related to a secondary peripheral nerve involvement due to LS inflammation and fibrosis. Further collaborative studies to confirm these findings are needed. PMID:25053924

  3. The risk of iatrogenic pneumothorax after electromyography.

    Science.gov (United States)

    Kassardjian, Charles D; O'gorman, Cullen M; Sorenson, Eric J

    2016-04-01

    Pneumothorax is a potentially serious complication of electromyography (EMG). Data on the frequency of pneumothorax after EMG are lacking. The purpose of this study was to determine the frequency, timing, and risk factors for iatrogenic pneumothorax after EMG. Cases of pneumothorax after EMG were reviewed for clinical, electrophysiological, and radiological data. Of 64,490 EMG studies, 7 patients had an association between the EMG and pneumothorax. All patients were symptomatic and presented within 24 hours of EMG. Sampling of serratus anterior and diaphragm was causative in 1 patient each. In 5 patients, multiple high-risk muscles were sampled. The highest frequency of pneumothorax was observed with examination of serratus anterior (0.445%) and diaphragm (0.149%). The frequency of symptomatic iatrogenic pneumothorax after EMG appears to be low, and examinations of serratus anterior and diaphragm carry the highest risk. Electromyographers should be aware of the risk of pneumothorax and should counsel patients accordingly. © 2015 Wiley Periodicals, Inc.

  4. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  5. Towards quantitative off-axis electron holographic mapping of the electric field around the tip of a sharp biased metallic needle

    DEFF Research Database (Denmark)

    Beleggia, Marco; Kasama, Takeshi; Larson, D. J.

    2014-01-01

    We apply off-axis electron holography and Lorentz microscopy in the transmission electron microscope to map the electric field generated by a sharp biased metallic tip. A combination of experimental data and modelling provides quantitative information about the potential and the field around...... the tip. Close to the tip apex, we measure a maximum field intensity of 82 MV/m, corresponding to a field k factor of 2.5, in excellent agreement with theory. In order to verify the validity of the measurements, we use the inferred charge density distribution in the tip region to generate simulated phase...

  6. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  7. Robust Features Of Surface Electromyography Signal

    International Nuclear Information System (INIS)

    Sabri, M I; Miskon, M F; Yaacob, M R

    2013-01-01

    Nowadays, application of robotics in human life has been explored widely. Robotics exoskeleton system are one of drastically areas in recent robotic research that shows mimic impact in human life. These system have been developed significantly to be used for human power augmentation, robotics rehabilitation, human power assist, and haptic interaction in virtual reality. This paper focus on solving challenges in problem using neural signals and extracting human intent. Commonly, surface electromyography signal (sEMG) are used in order to control human intent for application exoskeleton robot. But the problem lies on difficulty of pattern recognition of the sEMG features due to high noises which are electrode and cable motion artifact, electrode noise, dermic noise, alternating current power line interface, and other noise came from electronic instrument. The main objective in this paper is to study the best features of electromyography in term of time domain (statistical analysis) and frequency domain (Fast Fourier Transform).The secondary objectives is to map the relationship between torque and best features of muscle unit activation potential (MaxPS and RMS) of biceps brachii. This project scope use primary data of 2 male sample subject which using same dominant hand (right handed), age between 20–27 years old, muscle diameter 32cm to 35cm and using single channel muscle (biceps brachii muscle). The experiment conduct 2 times repeated task of contraction and relaxation of biceps brachii when lifting different load from no load to 3kg with ascending 1kg The result shows that Fast Fourier Transform maximum power spectrum (MaxPS) has less error than mean value of reading compare to root mean square (RMS) value. Thus, Fast Fourier Transform maximum power spectrum (MaxPS) show the linear relationship against torque experience by elbow joint to lift different load. As the conclusion, the best features is MaxPS because it has the lowest error than other features and

  8. Robust Features Of Surface Electromyography Signal

    Science.gov (United States)

    Sabri, M. I.; Miskon, M. F.; Yaacob, M. R.

    2013-12-01

    Nowadays, application of robotics in human life has been explored widely. Robotics exoskeleton system are one of drastically areas in recent robotic research that shows mimic impact in human life. These system have been developed significantly to be used for human power augmentation, robotics rehabilitation, human power assist, and haptic interaction in virtual reality. This paper focus on solving challenges in problem using neural signals and extracting human intent. Commonly, surface electromyography signal (sEMG) are used in order to control human intent for application exoskeleton robot. But the problem lies on difficulty of pattern recognition of the sEMG features due to high noises which are electrode and cable motion artifact, electrode noise, dermic noise, alternating current power line interface, and other noise came from electronic instrument. The main objective in this paper is to study the best features of electromyography in term of time domain (statistical analysis) and frequency domain (Fast Fourier Transform).The secondary objectives is to map the relationship between torque and best features of muscle unit activation potential (MaxPS and RMS) of biceps brachii. This project scope use primary data of 2 male sample subject which using same dominant hand (right handed), age between 20-27 years old, muscle diameter 32cm to 35cm and using single channel muscle (biceps brachii muscle). The experiment conduct 2 times repeated task of contraction and relaxation of biceps brachii when lifting different load from no load to 3kg with ascending 1kg The result shows that Fast Fourier Transform maximum power spectrum (MaxPS) has less error than mean value of reading compare to root mean square (RMS) value. Thus, Fast Fourier Transform maximum power spectrum (MaxPS) show the linear relationship against torque experience by elbow joint to lift different load. As the conclusion, the best features is MaxPS because it has the lowest error than other features and show

  9. Embroidered Electromyography: A Systematic Design Guide.

    Science.gov (United States)

    Shafti, Ali; Ribas Manero, Roger B; Borg, Amanda M; Althoefer, Kaspar; Howard, Matthew J

    2017-09-01

    Muscle activity monitoring or electromyography (EMG) is a useful tool. However, EMG is typically invasive, expensive and difficult to use for untrained users. A possible solution is textile-based surface EMG (sEMG) integrated into clothing as a wearable device. This is, however, challenging due to 1) uncertainties in the electrical properties of conductive threads used for electrodes, 2) imprecise fabrication technologies (e.g., embroidery, sewing), and 3) lack of standardization in design variable selection. This paper, for the first time, provides a design guide for such sensors by performing a thorough examination of the effect of design variables on sEMG signal quality. Results show that imprecisions in digital embroidery lead to a trade-off between low electrode impedance and high manufacturing consistency. An optimum set of variables for this trade-off is identified and tested with sEMG during a variable force isometric grip exercise with n = 12 participants, compared with conventional gel-based electrodes. Results show that thread-based electrodes provide a similar level of sensitivity to force variation as gel-based electrodes with about 90% correlation to expected linear behavior. As proof of concept, jogging leggings with integrated embroidered sEMG are made and successfully tested for detection of muscle fatigue while running on different surfaces.

  10. Use of surface electromyography in phonation studies: an integrative review

    Science.gov (United States)

    Balata, Patricia Maria Mendes; Silva, Hilton Justino da; Moraes, Kyvia Juliana Rocha de; Pernambuco, Leandro de Araújo; Moraes, Sílvia Regina Arruda de

    2013-01-01

    Summary Introduction: Surface electromyography has been used to assess the extrinsic laryngeal muscles during chewing and swallowing, but there have been few studies assessing these muscles during phonation. Objective: To investigate the current state of knowledge regarding the use of surface electromyography for evaluation of the electrical activity of the extrinsic muscles of the larynx during phonation by means of an integrative review. Method: We searched for articles and other papers in the PubMed, Medline/Bireme, and Scielo databases that were published between 1980 and 2012, by using the following descriptors: surface electromyography and voice, surface electromyography and phonation, and surface electromyography and dysphonia. The articles were selectedon the basis ofinclusion and exclusion criteria. Data Synthesis: This was carried out with a cross critical matrix. We selected 27 papers,i.e., 24 articles and 3 theses. The studies differed methodologically with regards to sample size and investigation techniques, making it difficult to compare them, but showed differences in electrical activity between the studied groups (dysphonicsubjects, non-dysphonicsubjects, singers, and others). Conclusion: Electromyography has clinical applicability when technical precautions with respect to application and analysis are obeyed. However, it is necessary to adopt a universal system of assessment tasks and related measurement techniques to allow comparisons between studies. PMID:25992030

  11. Use of surface electromyography in phonation studies: an integrative review

    Directory of Open Access Journals (Sweden)

    Balata, Patricia Maria Mendes

    2014-01-01

    Full Text Available Introduction: Surface electromyography has been used to assess the extrinsic laryngeal muscles during chewing and swallowing, but there have been few studies assessing these muscles during phonation. Objective: To investigate the current state of knowledge regarding the use of surface electromyography for evaluation of the electrical activity of the extrinsic muscles of the larynx during phonation by means of an integrative review. Method: We searched for articles and other papers in the PubMed, Medline/Bireme, and Scielo databases that were published between 1980 and 2012, by using the following descriptors: surface electromyography and voice, surface electromyography and phonation, and surface electromyography and dysphonia. The articles were selectedon the basis ofinclusion and exclusion criteria. Data Synthesis: This was carried out with a cross critical matrix. We selected 27 papers,i.e., 24 articles and 3 theses. The studies differed methodologically with regards to sample size and investigation techniques, making it difficult to compare them, but showed differences in electrical activity between the studied groups (dysphonicsubjects, non-dysphonicsubjects, singers, and others. Conclusion: Electromyography has clinical applicability when technical precautions with respect to application and analysis are obeyed. However, it is necessary to adopt a universal system of assessment tasks and related measurement techniques to allow comparisons between studies.

  12. Modified microdissection electrocautery needle

    OpenAIRE

    Singh, Virendra; Kumar, Pramod

    2014-01-01

    Electrocautery is routinely used in surgical procedures. The commercially available microdissection electrocautery needles are costly. To overcome this disadvantage, we have modified monopolar electrocautery tip to function as well as commercially available systems.

  13. Associations between apparent diffusion coefficient and electromyography parameters in myositis-A preliminary study.

    Science.gov (United States)

    Meyer, Hans-Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey

    2018-05-01

    MRI is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an emergent imaging modality sensitive to microstructural alterations in tissue. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules. Electromyography (EMG) is a clinically used diagnostic tool in myositis. The aim of this study was to elucidate possible associations between ADC values and EMG findings in myositis patients. Seven patients (eight investigated muscles) with myositis (mean age 51.43 ± 19 years) were included in this study. The diagnosis was confirmed by histopathology in every case. DWI was obtained with a 1.5-T scanner using two b-values 0 and 1000 s/mm². In all patients, a needle electromyography (EMG) was performed within 3 days to the MRI. The following EMG parameters were studied: motor unit action potential (MUAP) amplitudes and durations, as well as pathological spontaneous activity. Spearman's correlation coefficient was used to analyze associations between investigated parameters. The estimated mean ADC mean value was 1.51 ± 0.29 × 10 -3  mm²/s, mean ADC min was 1.28 ± 0.27 × 10 -3  mm²/s, and mean ADC max was 1.73 ± 0.28 × 10 -3  mm²/s. Correlation analysis identified significant associations between ADC mean and duration of the MUAP (p   = .78 P = .0279) and between ADC min and duration of the MUAP (p = .85, P = .01). There were no significant differences according to pathological spontaneous activity. ADC mean and ADC min showed strong positive correlations with the duration of the MUAP in myositis patients. Both modalities might similarly reflect muscle fiber loss in myositis patients.

  14. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types.

    Directory of Open Access Journals (Sweden)

    Lyubomyr Lytvynchuk

    Full Text Available A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements.

  15. Investigation of Physiological Properties of Nerves and Muscles Using Electromyography

    Science.gov (United States)

    Roe, Seán M.; Johnson, Christopher D.; Tansey, Etain A.

    2014-01-01

    The measurement and representation of the electrical activity of muscles [electromyography (EMG)] have a long history from the Victorian Era until today. Currently, EMG has uses both as a research tool, in noninvasively recording muscle activation, and clinically in the diagnosis and assessment of nerve and muscle disease and injury as well as in…

  16. Anal sphincter electromyography in patients with Anorectal Dysfunctions

    International Nuclear Information System (INIS)

    Trinchet Soler, Rafael; Hidalgo Marrero, Yanet; Espichicoque Megret, Arianne; Manzano Suarez, Jianeya; Perez Gonzales, Ruth Maite

    2009-01-01

    The purpose of this work is to evaluate the electromyography value of anal sphincter in patients with anorectal dysfunctions. Anorectal dysfunctions are frequent reason of pediatric consultation in children, especially with anal incontinence. A study of series of cases in patient with anorectal dysfunctions was carried out from January 2002 to January of 2006. 65 patients were studied. Anorectal malformations (ARM) represented the predominant affection with 38 patients (58.5%), prevailing the male sex in 25 patients (65.8%). Encopresis and intestinal agagliosis dicrease was observed. Sphincter was found before surgical treatment through electromyography in patients with anorectal malformations and colostomy; in those with definitive operation and open colostomy, it avoided the operation in a patient that did not have muscular activity of the external sphincter. In children already operated and with closed colostomy several electromyography changes were observed in correspondence with different incontinence grades. In encopresis cases the study was useful to rule out sphincter functional alterations. Electromyography was pathological in all the operated patients of intestinal aganglionosis. This procedure was very useful for anal incontinence study that helped to determine and establish the prognosis. (author)

  17. Laryngeal Electromyography for Prognosis of Vocal Fold Paralysis.

    Science.gov (United States)

    Pardo-Maza, Adriana; García-Lopez, Isabel; Santiago-Pérez, Susana; Gavilán, Javier

    2017-01-01

    This study aimed to determine the value of laryngeal electromyography in the prognosis of vocal fold paralysis. This is a retrospective descriptive study. This study included 80 patients diagnosed with unilateral or bilateral vocal fold paralysis on flexible laryngoscopy between 2002 and 2014 in a tertiary medical center. Laryngeal electromyography using a standardized protocol was performed; the outcome measures were classified and analyzed into two groups according to the degree of injury. Group 1 included patients with mild to moderate injury, and group 2 included patients with severe to complete injury. Prognosis was correlated with vocal fold motion recovery status with a minimum of 6 months of follow-up since the symptoms onset using positive and negative predictive values. Sixty patients showed acute or chronic recurrent laryngeal neuropathy in laryngeal electromyography. Twelve of 41 patients included in group 1 recovered motion, and 30 of 35 patients included in group 2 did not recover, resulting in 88.2% of positive predictive value and 35.7% of negative predictive value. Our data confirm that laryngeal electromyography is a useful clinical tool in predicting poor recovery in patients with vocal fold paralysis. It allows identification of candidates for early intervention. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  19. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  20. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  1. Assessment of a wearable force- and electromyography device and comparison of the related signals for myocontrol

    Directory of Open Access Journals (Sweden)

    Mathilde Connan

    2016-11-01

    Full Text Available In the frame of assistive robotics, multi-finger prosthetic hand/wrists have recently appeared,offering an increasing level of dexterity; however, in practice their control is limited to a few handgrips and still unreliable, with the effect that pattern recognition has not yet appeared in the clinicalenvironment. According to the scientific community, one of the keys to improve the situation ismulti-modal sensing, i.e., using diverse sensor modalities to interpret the subject’s intent andimprove the reliability and safety of the control system in daily life activities. In this work, wefirst describe and test a novel wireless, wearable force- and electromyography device; throughan experiment conducted on ten intact subjects, we then compare the obtained signals bothqualitatively and quantitatively, highlighting their advantages and disadvantages. Our resultsindicate that force-myography yields signals which are more stable across time during whenevera pattern is held, than those obtained by electromyography. We speculate that fusion of the twomodalities might be advantageous to improve the reliability of myocontrol in the near future.

  2. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  3. Investigating Facial Electromyography as an Indicator of Cognitive Workload

    Science.gov (United States)

    2017-02-22

    operator’s ability to perform at the level required to prevent hazardous consequences (Young & Stanton, 2002). Cognitive overload and underload can both...the operator’s performance to lessen performance abatement induced by cognitive overload or underload (Wilson & Russell, 2007; Hoepf, Middendorf...Investigating Facial Electromyography as an Indicator of Cognitive Workload 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d

  4. Basic Hand Gestures Classification Based on Surface Electromyography

    Directory of Open Access Journals (Sweden)

    Aleksander Palkowski

    2016-01-01

    Full Text Available This paper presents an innovative classification system for hand gestures using 2-channel surface electromyography analysis. The system developed uses the Support Vector Machine classifier, for which the kernel function and parameter optimisation are conducted additionally by the Cuckoo Search swarm algorithm. The system developed is compared with standard Support Vector Machine classifiers with various kernel functions. The average classification rate of 98.12% has been achieved for the proposed method.

  5. Estimation of muscle fatigue by ratio of mean frequency to average rectified value from surface electromyography.

    Science.gov (United States)

    Fernando, Jeffry Bonar; Yoshioka, Mototaka; Ozawa, Jun

    2016-08-01

    A new method to estimate muscle fatigue quantitatively from surface electromyography (EMG) is proposed. The ratio of mean frequency (MNF) to average rectified value (ARV) is used as the index of muscle fatigue, and muscle fatigue is detected when MNF/ARV falls below a pre-determined or pre-calculated baseline. MNF/ARV gives larger distinction between fatigued muscle and non-fatigued muscle. Experiment results show the effectiveness of our method in estimating muscle fatigue more correctly compared to conventional methods. An early evaluation based on the initial value of MNF/ARV and the subjective time when the subjects start feeling the fatigue also indicates the possibility of calculating baseline from the initial value of MNF/ARV.

  6. Surface electromyography in orthodontics – a literature review

    Science.gov (United States)

    WoŸniak, Krzysztof; Piątkowska, Dagmara; Lipski, Mariusz; Mehr, Katarzyna

    2013-01-01

    Electromyography is the most objective and reliable technique for evaluating muscle function and efficiency by detecting their electrical potentials. It makes it possible to assess the extent and duration of muscle activity. The main aim of surface electromyography is to detect signals from many muscle fibers in the area of the detecting surface electrodes. These signals consist of a weighted summation of the spatial and temporal activity of many motor units. Hence, the analysis of the recordings is restricted to an assessment of general muscle activity, the cooperation of different muscles, and the variability of their activity over time. This study presents the main assumptions in the assessment of electrical muscle activity through the use of surface electromyography, along with its limitations and possibilities for further use in many areas of orthodontics. The main clinical uses of sEMG include the diagnostics and therapy of temporomandibular joint disorders, an assessment of the extent of stomatognathic system dysfunctions in subjects with malocclusion, and the monitoring of orthodontic therapies. PMID:23722255

  7. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  8. Needling the early universe

    International Nuclear Information System (INIS)

    Hawkins, I.; Wright, E.L.

    1988-01-01

    The possibility that the whole microwave background can be produced by a bright population of pregalactic stars at a redshift of a few hundred is explored. The radiation is thermalized by a combination of amorphous silicate, amorphous carbon, graphite, and needle-shaped conducting grains which give rise to the opacity needed at wavelengths greater than 3 cm. The occurrence of distortion in a primordial microwave background spectrum due to its interaction with Population III stars and dust is investigated. The possibility of producing deviations small enough to be consistent with the best available observations, but still detectable by COBE, is considered. 65 references

  9. A more precise, repeatable and diagnostic alternative to surface electromyography

    DEFF Research Database (Denmark)

    Harrison, Adrian P

    2018-01-01

    Acoustic myography (AMG) enables a detailed and accurate measurement of those muscles involved in a particular movement and is independent of electrical signals between the nerve and muscle, measuring solely muscle contractions, unlike surface electromyography (sEMG). With modern amplifiers....../coordination (E-score), spatial summation (S-score) and temporal summation (T-score). It is concluded that modern AMG units have the potential to accurately assess patients with neuromuscular and musculoskeletal complaints in hospital clinics, home monitoring situations as well as sports settings....

  10. Detection of tonic epileptic seizures based on surface electromyography

    DEFF Research Database (Denmark)

    Larsen, Sigge N.; Conradsen, Isa; Beniczky, Sandor

    2014-01-01

    The purpose of this project was to design an algorithm for detection of tonic seizures based on surface electromyography signals from the deltoids. A successful algorithm has a future prospect of being implemented in a wearable device as part of an alarm system. This has already been done......, median frequency, zero crossing rate and approximate entropy. These features were used as input in the random forest classifier to decide if a data segment was from a seizure or not. The goal was to develop a generic algorithm for all tonic seizures, but better results were achieved when certain...

  11. [Surface electromyography signal classification using gray system theory].

    Science.gov (United States)

    Xie, Hongbo; Ma, Congbin; Wang, Zhizhong; Huang, Hai

    2004-12-01

    A new method based on gray correlation was introduced to improve the identification rate in artificial limb. The electromyography (EMG) signal was first transformed into time-frequency domain by wavelet transform. Singular value decomposition (SVD) was then used to extract feature vector from the wavelet coefficient for pattern recognition. The decision was made according to the maximum gray correlation coefficient. Compared with neural network recognition, this robust method has an almost equivalent recognition rate but much lower computation costs and less training samples.

  12. Mosquito inspired medical needles

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Hesselberg, Thomas; Drakidis, Alexandros Dimitrios

    2017-01-01

    The stinging proboscis in mosquitos have diameters of only 40-100 μm which is much less than the thinnest medical needles and the mechanics of these natural stinging mechanisms have therefore attracted attention amongst developers of injection devises. The mosquito use a range of different...... strategies to lower the required penetration force hence allowing a thinner and less stiff proboscis structure. Earlier studies of the mosquito proboscis insertion strategies have shown how each of the single strategies reduces the required penetration force. The present paper gives an overview...... of the advanced set of mechanisms that allow the mosquito to penetrate human skin and also presents other biological mechanisms that facilitate skin penetration. Results from experiments in a skin mimic using biomimetic equivalents to the natural mechanisms are presented. This includes skin stretching, insertion...

  13. History of electromyography and nerve conduction studies: A tribute to the founding fathers.

    Science.gov (United States)

    Kazamel, Mohamed; Warren, Paula Province

    2017-09-01

    The early development of nerve conduction studies (NCS) and electromyography (EMG) was linked to the discovery of electricity. This relationship had been concluded by observing the effect of applying electricity to the body of an animal and discovering that nerves and muscles themselves could produce electricity. We attempt to review the historical evolution of NCS and EMG over the last three centuries by reviewing the landmark publications of Galvani, Adrian, Denny-Brown, Larrabee, and Lambert. In 1771, Galvani showed that electrical stimulation of animal muscle tissue produced contraction and, thereby, the concept of animal electricity was born. In 1929, Adrian devised a method to record a single motor unit potential by connecting concentric needle electrodes to an amplifier and a loud speaker. In 1938, Denny-Brown described the fasciculation potentials and separated them from fibrillations. Toward the end of World War II, Larrabee began measuring the compound muscle action potential in healthy and injured nerves of war victims. In 1957, Lambert and Eaton described the electrophysiologic features of a new myasthenic syndrome associated with lung carcinoma. Overall, research on this topic was previously undertaken by neurophysiologists and then later by neurologists, with Adrian most likely being the first neurologist to be involved. The field greatly benefited from the invention of equipment that was capable of amplifying small bioelectrical currents by the beginning of the 20th century. Significant scientific and technical advances were later made during and after World War II which provided a large patient population with nerve injuries to study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Effect of fuel and nozzle geometry on the off-axis oscillation of needle in diesel injectors using high-speed X-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Zhang, X.; Liu, J.; Wang, J.

    2016-01-01

    The diesel spray characteristics are strongly influenced by the flow dynamics inside the injector nozzle. Moreover, the off-axis oscillation of needle could lead to variation of orifice flow in the nozzle. In this paper, the needle oscillation was investigated using high-speed X-ray phase contrast imaging and quantitative image processing. The effects of fuel, injection pressure and nozzle geometry on the needle oscillation were analyzed. The results showed that the vertical and horizontal oscillation of needle was independent on the injection pressure. The maximum oscillation range of 14μ m was found. Biodiesel application slightly decreased the needle oscillation due to high viscosity. The needle oscillation range increased generally with increasing hole number. The larger needle oscillation in multi-hole injectors was dominated by the geometry problem or production issue at lower needle lift. In addition, the influence of needle oscillation on the spray morphology was also discussed.

  15. Effect of fuel and nozzle geometry on the off-axis oscillation of needle in diesel injectors using high-speed X-ray phase contrast imaging

    Science.gov (United States)

    Zhang, X.; Liu, J.; Wang, J.

    2016-05-01

    The diesel spray characteristics are strongly influenced by the flow dynamics inside the injector nozzle. Moreover, the off-axis oscillation of needle could lead to variation of orifice flow in the nozzle. In this paper, the needle oscillation was investigated using high-speed X-ray phase contrast imaging and quantitative image processing. The effects of fuel, injection pressure and nozzle geometry on the needle oscillation were analyzed. The results showed that the vertical and horizontal oscillation of needle was independent on the injection pressure. The maximum oscillation range of 14μ m was found. Biodiesel application slightly decreased the needle oscillation due to high viscosity. The needle oscillation range increased generally with increasing hole number. The larger needle oscillation in multi-hole injectors was dominated by the geometry problem or production issue at lower needle lift. In addition, the influence of needle oscillation on the spray morphology was also discussed.

  16. Swallowing in patients with Parkinson's disease: a surface electromyography study.

    Science.gov (United States)

    Ws Coriolano, Maria das Graças; R Belo, Luciana; Carneiro, Danielle; G Asano, Amdore; Al Oliveira, Paulo José; da Silva, Douglas Monteiro; G Lins, Otávio

    2012-12-01

    Our goal was to study deglutition of Parkinson's disease (PD) patients and normal controls (NC) using surface electromyography (sEMG). The study included 15 patients with idiopathic PD and 15 age-matched normal controls. Surface electromyography was collected over the suprahyoid muscle group. Conditions were the following: swallow at once 10 and 20 ml of water and 5 and 10 ml of yogurt of firm consistency, and freely drink 100 ml of water. During swallowing, durations of sEMG were significantly longer in PD patients than in normal controls but no significant differences of amplitudes were found. Eighty percent of the PD patients and 20 % of the NC needed more than one swallow to consume 20 ml of water, while 70 % of the PD patients and none of the NC needed more than one swallow to consume 5 ml of yogurt. PD patients took significantly more time and needed significantly more swallows to drink 100 ml of water than normal controls. We conclude that sEMG might be a simple and useful tool to study and monitor deglutition in PD patients.

  17. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  18. Needle Biopsy of the Lung

    Science.gov (United States)

    ... clip. The needle is hollow so it can capture the tissue specimen. There are several types of ... breath, difficulty in catching your breath, rapid pulse (heart rate), sharp chest or shoulder pain with breathing, ...

  19. Needle-free influenza vaccination

    NARCIS (Netherlands)

    Amorij, Jean-Pierre; Hinrichs, Wouter L.J.; Frijlink, Henderik W.; Wilschut, Jan C.; Huckriede, Anke

    2010-01-01

    Vaccination is the cornerstone of influenza control in epidemic and pandemic situations. Influenza vaccines are typically given by intramuscular injection. However, needle-free vaccinations could offer several distinct advantages over intramuscular injections: they are pain-free, easier to

  20. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  1. The correlation between surface electromyography and bite force of mastication muscles in Asian young adults.

    Science.gov (United States)

    Yen, Cheng-I; Mao, Shih-Hsuan; Chen, Chih-Hao; Chen, Chien-Tzung; Lee, Ming-Yih

    2015-05-01

    Mastication function is related to mandible movement, muscle strength, and bite force. No standard device for measuring bite force has been developed. A linear relationship between electromyographic activity and bite force has been reported by several investigators, but data on the reliability of this relationship remain limited in Asian young adults. The purpose of this study was to develop a clinically applicable, reliable, quantitative, and noninvasive system to measure the kinetic mastication function and observe the correlation between surface electromyography (sEMG) and bite force. The study group consisted of 41 young healthy adults (24 men and 17 women). Surface electromyography was used to evaluate bilateral temporalis and masseter muscle activities, and an occlusal bite force system was used concurrently to measure the bite force during maximal voluntary biting. Bilateral symmetry was compared, and the correlation between EMG and bite force was calculated. The sEMG signals were 107.7±55.0 μV and 106.0±56.0 μV (P=0.699) on right and left temporalis muscles and 183.7±86.2 μV and 194.8±94.3 μV (P=0.121) on right and left masseter muscles, respectively. The bite force was 5.0±3.2 kg on the right side and 5.7±4.0 kg on the left side (P=0.974). A positive correlation between sEMG and bite force was observed. The correlation coefficient between the temporalis muscle and bite force was 0.512, and that between the masseter muscle and bite force was 0.360. No significant difference between the bilateral electromyographic activities of the temporalis and masseter muscles and bilateral bite force was observed in young healthy adults in Taiwan. A positive correlation between sEMG signals and bite force was noted. By combining sEMG and bite force, we developed a clinically applicable, quantitative, reliable, and noninvasive system for evaluating mastication function by using characteristics of biofeedback.

  2. Congenital multiple cranial neuropathies: Relevance of orofacial electromyography in infants.

    Science.gov (United States)

    Renault, Francis; Flores-Guevara, Roberto; Baudon, Jean-Jacques; Vazquez, Marie-Paule

    2015-11-01

    The aim of this study was to assess diagnoses and outcomes of infants with 2 or more cranial neuropathies identified using orofacial electromyography (EMG). This retrospective study involved 90 patients. Diagnoses took into account clinical, radiological, and genetic data. EMG examined the orbicularis oculi, genioglossus, and levator veli palatini muscles, and blink responses. To evaluate outcome, neurological disability, respiratory complications, and feeding difficulties were recorded. The patients had malformation syndromes (59), encephalopathies (29), or no underlying disorders (2). Neurogenic EMG signs were detected in a mean of 4 muscles, reflecting a mean of 3 affected nerves. EMG identified a higher number of neuropathies than clinical examination alone (82 vs. 31, facial; 56 vs. 2, pharyngeal; 25 vs. 3, hypoglossal). Poor outcome and death were more frequent when EMG identified ≥4 affected nerves (P = 0.02). EMG highlights multiple cranial neuropathies that can be clinically silent in infants with malformation syndromes or encephalopathies. © 2015 Wiley Periodicals, Inc.

  3. SURFACE ELECTROMYOGRAPHY IN BIOMECHANICS: APPLICATIONS AND SIGNAL ANALYSIS ASPECTS

    Directory of Open Access Journals (Sweden)

    DEAK GRAłIELA-FLAVIA

    2009-12-01

    Full Text Available Surface electromyography (SEMG is a technique for detecting and recording the electrical activity of the muscles using surface electrodes. The EMG signal is used in biomechanics mainly as an indicator of the initiation of muscle activation, as an indicator of the force produced by a contracting muscle, and as an index ofthe fatigue occurring within a muscle. EMG, used as a method of investigation, can tell us if the muscle is active or not, if the muscle is more or less active, when it is on or off, how much active is it, and finally, if it fatigues.The purpose of this article is to discuss some specific EMG signal analysis aspects with emphasis on comparison type analysis and frequency fatigue analysis.

  4. Analysis of prosody in finger braille using electromyography.

    Science.gov (United States)

    Miyagi, Manabi; Nishida, Masafumi; Horiuchi, Yasuo; Ichikawa, Akira

    2006-01-01

    Finger braille is one of the communication methods for the deaf blind. The interpreter types braille codes on the fingers of deaf blind. Finger braille seems to be the most suitable medium for real-time communication by its speed and accuracy of transmitting characters. We hypothesize that the prosody information exists in the time structure and strength of finger braille typing. Prosody is the paralinguistic information that has functions to transmit the sentence structure, prominence, emotions and other form of information in real time communication. In this study, we measured the surface electromyography (sEMG) of finger movement to analyze the typing strength of finger braille. We found that the typing strength increases at the beginning of a phrase and a prominent phrase. The result shows the possibility that the prosody in the typing strength of finger braille can be applied to create an interpreter system for the deafblind.

  5. Wavelet transform analysis of electromyography kung fu strikes data.

    Science.gov (United States)

    Neto, Osmar Pinto; Marzullo, Ana Carolina de Miranda

    2009-11-01

    In martial arts and contact sports strikes are performed at near maximum speeds. For that reason, electromyography (EMG) analysis of such movements is non-trivial. This paper has three main goals: firstly, to investigate the differences in the EMG activity of muscles during strikes performed with and without impacts; secondly, to assess the advantages of using Sum of Significant Power (SSP) values instead of root mean square (rms) values when analyzing EMG data; and lastly to introduce a new method of calculating median frequency values using wavelet transforms (WMDF). EMG data of the deltoid anterior (DA), triceps brachii (TB) and brachioradialis (BR) muscles were collected from eight Kung Fu practitioners during strikes performed with and without impacts. SSP results indicated significant higher muscle activity (p = 0.023) for the strikes with impact. WMDF results, on the other hand, indicated significant lower values (p = 0. 007) for the strikes with impact. SSP results presented higher sensitivity than rms to quantify important signal differences and, at the same time, presented lower inter-subject coefficient of variations. The result of increase in SSP values and decrease in WMDF may suggest better synchronization of motor units for the strikes with impact performed by the experienced Kung Fu practitioners. Key PointsThe results show higher muscle activity and lower electromyography median frequencies for strikes with impact compared to strikes without.SSP results presented higher sensitivity and lower inter-subject coefficient of variations than rms results.Kung Fu palm strikes with impact may present better motor units' synchronization than strikes without.

  6. Occlusal splint versus modified nociceptive trigeminal inhibition splint in bruxism therapy: a randomized, controlled trial using surface electromyography.

    Science.gov (United States)

    Dalewski, B; Chruściel-Nogalska, M; Frączak, B

    2015-12-01

    An occlusal splint and a modified nociceptive trigeminal inhibition splint (AMPS, anterior deprogrammer, Kois deprogrammer, Lucia jig, etc.) are commonly and quite frequently used in the treatment of masticatory muscle disorders, although their sustainable and long-lasting effect on these muscles' function is still not very well known. Results of scant surface electromyography studies in patients with temporomandibular disorders have been contradictory. The aim of this study was to evaluate both devices in bruxism therapy; EMG activity levels during postural activity and maximum voluntary contraction of the superficial temporal and masseter muscles were compared before and after 30 days of treatment. Surface electromyography of the examined muscles was performed in two groups of bruxers (15 patients each). Patients in the first group used occlusal splints, while those in the second used modified nociceptive trigeminal inhibition splints. The trial was randomized, controlled and semi-blind. Neither device affected the asymmetry index or postural activity/maximum voluntary contraction ratio after 1 month of treatment. Neither the occlusal nor the nociceptive trigeminal inhibition splint showed any significant influence on the examined muscles. Different scientific methods should be considered in clinical applications that require either direct influence on the muscles' bioelectrical activity or a quantitative measurement of the treatment quality. © 2015 Australian Dental Association.

  7. Vocal fold motion outcome based on excellent prognosis with laryngeal electromyography.

    Science.gov (United States)

    Smith, Libby J; Rosen, Clark A; Munin, Michael C

    2016-10-01

    As laryngeal electromyography (LEMG) becomes more refined, accurate predictions of vocal fold motion recovery are possible. Focus has been on outcomes for patients with poor prognosis for vocal fold motion recovery. Limited information is available regarding the expected rate of purposeful vocal fold motion recovery when there is good to normal motor recruitment, no signs of denervation, and no signs of synkinetic activity with LEMG, termed excellent prognosis. The objective of this study is to determine the rate of vocal fold motion recovery with excellent prognosis findings on LEMG after acute recurrent laryngeal nerve injury. Retrospective review. Patients undergoing a standardized LEMG protocol, consisting of qualitative (evaluation of motor recruitment, motor unit configuration, detection of fibrillations, presence of synkinesis) and quantitative (turns analysis) measurements were evaluated for purposeful vocal-fold motion recovery, calculated after at least 6 months since onset of injury. Twenty-three patients who underwent LEMG for acute vocal fold paralysis met the inclusion criteria of excellent prognosis. Eighteen patients (78.3%) recovered vocal fold motion, as determined by flexible laryngoscopy. Nearly 80% of patients determined to have excellent prognosis for vocal fold motion recovery experienced return of vocal fold motion. This information will help clinicians not only counsel their patients on expectations but will also help guide treatment. 4. Laryngoscope, 126:2310-2314, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Discrete wavelet transform analysis of surface electromyography for the fatigue assessment of neck and shoulder muscles.

    Science.gov (United States)

    Chowdhury, Suman Kanti; Nimbarte, Ashish D; Jaridi, Majid; Creese, Robert C

    2013-10-01

    Assessment of neuromuscular fatigue is essential for early detection and prevention of risks associated with work-related musculoskeletal disorders. In recent years, discrete wavelet transform (DWT) of surface electromyography (SEMG) has been used to evaluate muscle fatigue, especially during dynamic contractions when the SEMG signal is non-stationary. However, its application to the assessment of work-related neck and shoulder muscle fatigue is not well established. Therefore, the purpose of this study was to establish DWT analysis as a suitable method to conduct quantitative assessment of neck and shoulder muscle fatigue under dynamic repetitive conditions. Ten human participants performed 40min of fatiguing repetitive arm and neck exertions while SEMG data from the upper trapezius and sternocleidomastoid muscles were recorded. The ten of the most commonly used wavelet functions were used to conduct the DWT analysis. Spectral changes estimated using power of wavelet coefficients in the 12-23Hz frequency band showed the highest sensitivity to fatigue induced by the dynamic repetitive exertions. Although most of the wavelet functions tested in this study reasonably demonstrated the expected power trend with fatigue development and recovery, the overall performance of the "Rbio3.1" wavelet in terms of power estimation and statistical significance was better than the remaining nine wavelets. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Fuzzy approximate entropy analysis of chaotic and natural complex systems: detecting muscle fatigue using electromyography signals.

    Science.gov (United States)

    Xie, Hong-Bo; Guo, Jing-Yi; Zheng, Yong-Ping

    2010-04-01

    In the present contribution, a complexity measure is proposed to assess surface electromyography (EMG) in the study of muscle fatigue during sustained, isometric muscle contractions. Approximate entropy (ApEn) is believed to provide quantitative information about the complexity of experimental data that is often corrupted with noise, short data length, and in many cases, has inherent dynamics that exhibit both deterministic and stochastic behaviors. We developed an improved ApEn measure, i.e., fuzzy approximate entropy (fApEn), which utilizes the fuzzy membership function to define the vectors' similarity. Tests were conducted on independent, identically distributed (i.i.d.) Gaussian and uniform noises, a chirp signal, MIX processes, Rossler equation, and Henon map. Compared with the standard ApEn, the fApEn showed better monotonicity, relative consistency, and more robustness to noise when characterizing signals with different complexities. Performance analysis on experimental EMG signals demonstrated that the fApEn significantly decreased during the development of muscle fatigue, which is a similar trend to that of the mean frequency (MNF) of the EMG signal, while the standard ApEn failed to detect this change. Moreover, fApEn of EMG demonstrated a better robustness to the length of the analysis window in comparison with the MNF of EMG. The results suggest that the fApEn of an EMG signal may potentially become a new reliable method for muscle fatigue assessment and be applicable to other short noisy physiological signal analysis.

  10. Electromyography and the study of sports movements: a review.

    Science.gov (United States)

    Clarys, J P; Cabri, J

    1993-10-01

    Within electromyography (EMG), a particular specialty has been developed wherein the aim is to use EMG for the study of muscular function and co-ordination. This area of research is usually called kinesiological EMG. The general aims of kinesiological EMG are to analyse the function and co-ordination of muscles in different movements and postures, in healthy subjects as well as in the disabled, in skilled actions as well as during training, in humans as well as in animals, under laboratory conditions as well as during daily or vocational activities. This is often done by a combination of electromyographical and kinesiological or biomechanical measurement techniques. Because there are over 400 skeletal muscles in the human body and both irregular and complex involvement of the muscles may occur in neuromuscular diseases and in voluntary occupational or sports movements, it is impossible to sample all of the muscles of the entire body during the performance of complex motor skills. In addition, the measurement of kinesiological EMG in sport and specific field circumstances, such as the track and/or soccer field, the alpine ski slope, the swimming pool and the ice rink, demands a specific technological and methodological approach, adaptable to both the field and the sport circumstances. Sport movement techniques and skills, training approaches and methods, ergonomic verification of the human-machine interaction have, amongst others, a highly specialized muscular activity in common. The knowledge of such muscular action in all its aspects, its evaluation and its feedback should allow for the optimization of movement, of sports materials, of training possibilities and, in the end, of sports performance. Drawing conclusions from a review of the EMG research of 32 sports, covering over 100 different complex skills, including methodological approaches, is an impossible task. We have attempted to set standards concerning the EMG methodology at the beginning of this review

  11. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  12. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    needle is used to insert high strength yarns (i.e., threads) through the dry fabric or prepreg laminate , leaving a loose thread loop underneath [9-11...capability which uses commercially-available felting needles to insert z-fibers into composite laminates at different angles (±45/90°) relative to the... laminate plane. Previous work with needled glass/epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  13. Neural mechanisms of intermuscular coherence: Implications for the rectification of surface electromyography

    NARCIS (Netherlands)

    Boonstra, T.W.; Breakspear, M.

    2012-01-01

    Oscillatory activity plays a crucial role in corticospinal control of muscle synergies and is widely investigated using corticospinal and intermuscular synchronization. However, the neurophysiological mechanisms that translate these rhythmic patterns into surface electromyography (EMG) are not well

  14. Value of Laryngeal Electromyography in Spasmodic Dysphonia Diagnosis and Therapy.

    Science.gov (United States)

    Yang, Qingwen; Xu, Wen; Li, Yun; Cheng, Liyu

    2015-07-01

    To investigate the role of laryngeal electromyography (LEMG) in the diagnosis and treatment of spasmodic dysphonia (SD). The clinical manifestations, characteristics of motor unit potentials (MUPs), recruitment potentials, and laryngeal nerve evoked potentials (EPs) in LEMG, as well as the changes after botulinum toxin (BTX) treatment, were analyzed in 39 patients with adductor SD. The main clinical manifestations were a strained voice and phonation interruptions; in addition, the patients displayed hyper-adducted vocal folds during phonation. LEMG revealed significantly increased amplitudes of the thyroarytenoid muscle MUPs. The recruitment potentials were in a dense bunch, discharging full interference patterns with significantly increased amplitudes; the mean and maximum amplitude of recruitment potentials were 3090 μV and 5000 μV, respectively. The amplitude of EPs of thyroarytenoid muscle increased significantly; the mean and maximum amplitudes were 10.3 mV and 26.3 mV, respectively. After BTX was injected, the LEMG revealed denervation changes, and the EPs weakened or disappeared in the injected muscle. SD could be diagnosed, and the therapeutic efficacy of SD treatments could be evaluated based on clinical characteristics combined with LEMG characteristics. The increased amplitudes of the recruitment potentials and EPs of the thyroarytenoid muscle were the characteristic indexes. After BTX was injected, denervated potential characteristics appeared in the muscles. © The Author(s) 2015.

  15. Evaluation of upper limb muscle fatigue based on surface electromyography.

    Science.gov (United States)

    Zhou, Qianxiang; Chen, Yuhong; Ma, Chao; Zheng, Xiaohui

    2011-10-01

    Fatigue is believed to be a major contributory factor to occupational injuries in machine operators. The development of accurate and usable techniques to measure operator fatigue is therefore important. In this study, we used a novel method based on surface electromyography (sEMG) of the biceps brachii and the Borg scale to evaluate local muscle fatigue in the upper limb after isometric muscle action. Thirteen young males performed isometric actions with the upper limb at different force levels. sEMG activities of the biceps brachii were recorded during the actions. Borg scales were used to evaluate the subjective sensation of local fatigue of the biceps brachii after the actions. sEMG activities were analyzed using the one-third band octave method, and an equation to determine the degree of fatigue was derived based on the relationship between the variable and the Borg scale. The results showed that the relationship could be expressed by a conic curve, and could be used to evaluate muscle fatigue during machine operation.

  16. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography

    Directory of Open Access Journals (Sweden)

    Bruno Moreira Gavassi

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS.METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient. No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4% while in the sagittal plane, 226 screws were found in ideal position (80.4%. Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281 of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.

  17. WAVELET TRANSFORM ANALYSIS OF ELECTROMYOGRAPHY KUNG FU STRIKES DATA

    Directory of Open Access Journals (Sweden)

    Ana Carolina de Miranda Marzullo

    2009-11-01

    Full Text Available In martial arts and contact sports strikes are performed at near maximum speeds. For that reason, electromyography (EMG analysis of such movements is non-trivial. This paper has three main goals: firstly, to investigate the differences in the EMG activity of muscles during strikes performed with and without impacts; secondly, to assess the advantages of using Sum of Significant Power (SSP values instead of root mean square (rms values when analyzing EMG data; and lastly to introduce a new method of calculating median frequency values using wavelet transforms (WMDF. EMG data of the deltoid anterior (DA, triceps brachii (TB and brachioradialis (BR muscles were collected from eight Kung Fu practitioners during strikes performed with and without impacts. SSP results indicated significant higher muscle activity (p = 0.023 for the strikes with impact. WMDF results, on the other hand, indicated significant lower values (p = 0. 007 for the strikes with impact. SSP results presented higher sensitivity than rms to quantify important signal differences and, at the same time, presented lower inter-subject coefficient of variations. The result of increase in SSP values and decrease in WMDF may suggest better synchronization of motor units for the strikes with impact performed by the experienced Kung Fu practitioners

  18. Time-varying surface electromyography topography as a prognostic tool for chronic low back pain rehabilitation.

    Science.gov (United States)

    Hu, Yong; Kwok, Jerry Weilun; Tse, Jessica Yuk-Hang; Luk, Keith Dip-Kei

    2014-06-01

    Nonsurgical rehabilitation therapy is a commonly used strategy to treat chronic low back pain (LBP). The selection of the most appropriate therapeutic options is still a big challenge in clinical practices. Surface electromyography (sEMG) topography has been proposed to be an objective assessment of LBP rehabilitation. The quantitative analysis of dynamic sEMG would provide an objective tool of prognosis for LBP rehabilitation. To evaluate the prognostic value of quantitative sEMG topographic analysis and to verify the accuracy of the performance of proposed time-varying topographic parameters for identifying the patients who have better response toward the rehabilitation program. A retrospective study of consecutive patients. Thirty-eight patients with chronic nonspecific LBP and 43 healthy subjects. The accuracy of the time-varying quantitative sEMG topographic analysis for monitoring LBP rehabilitation progress was determined by calculating the corresponding receiver-operating characteristic (ROC) curves. Physiologic measure was the sEMG during lumbar flexion and extension. Patients who suffered from chronic nonspecific LBP without the history of back surgery and any medical conditions causing acute exacerbation of LBP during the clinical test were enlisted to perform the clinical test during the 12-week physiotherapy (PT) treatment. Low back pain patients were classified into two groups: "responding" and "nonresponding" based on the clinical assessment. The responding group referred to the LBP patients who began to recover after the PT treatment, whereas the nonresponding group referred to some LBP patients who did not recover or got worse after the treatment. The results of the time-varying analysis in the responding group were compared with those in the nonresponding group. In addition, the accuracy of the analysis was analyzed through ROC curves. The time-varying analysis showed discrepancies in the root-mean-square difference (RMSD) parameters between the

  19. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  20. Determination of effective treatment duration of interferential current therapy using electromyography

    OpenAIRE

    Youn, Jong-In; Lee, Ho Sub; Lee, Sangkwan

    2016-01-01

    [Purpose] This study used electromyography to measure the effective treatment duration of interferential current therapy for muscle fatigue. [Subjects and Methods] Fifteen healthy adult men volunteered to participate in the study (age: 24.2 ? 1.3?years; weight: 67.6 ? 4.92?kg; height: 176.4 ? 4.92?cm). All subjects performed 5?min of isometric back extension exercise to produce muscle fatigue, and were then treated with interferential current therapy for 15?min, with electromyography monitori...

  1. Relations between Scots pine needle element concentrations and decreased needle longevity along pollution gradients

    International Nuclear Information System (INIS)

    Lamppu, Jukka; Huttunen, Satu

    2003-01-01

    Deceased needle longevity was related to increased heavy metal concentrations. - Scots pine (Pinus sylvestris L.) shoots were sampled along transects near one urban pollution source and two smelters. Needle Mg, P and K concentrations decreased from the second to the fourth age class linearly with needle survival along the urban pollution gradient. Still, over 80% of the average concentration of these nutrients remained in the fourth needle age class. Decreased needle longevity was closely related to the increased heavy metal concentrations near the smelters. Near the urban pollution source, it was related to the increased annual needle mass and the increased needle nutrient concentrations. Decreased Mn accumulation along with needle age was detected near all pollution sources. Leaching of Mn from needles and especially from soil as a cause of decreased needle concentrations is discussed

  2. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring.

    Science.gov (United States)

    Ren, Lei; Jiang, Qing; Chen, Keyun; Chen, Zhipeng; Pan, Chengfeng; Jiang, Lelun

    2016-06-17

    A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII) was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG), electrocardiography (ECG), and electroencephalograph (EEG) were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.

  3. Fabrication of a Micro-Needle Array Electrode by Thermal Drawing for Bio-Signals Monitoring

    Directory of Open Access Journals (Sweden)

    Lei Ren

    2016-06-01

    Full Text Available A novel micro-needle array electrode (MAE fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid (PLGA into a micro-needle array (MA by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-skin interface impedance (EII was recorded as the insertion force was applied on the MAE. The insertion process of the MAE was also simulated by the finite element method. Results showed that MAE could insert into skin with a relatively low compression force and maintain stable contact impedance between the MAE and skin. Bio-signals, including electromyography (EMG, electrocardiography (ECG, and electroencephalograph (EEG were also collected. Test results showed that the MAE could record EMG, ECG, and EEG signals with good fidelity in shape and amplitude in comparison with the commercial Ag/AgCl electrodes, which proves that MAE is an alternative electrode for bio-signals monitoring.

  4. Quantitative analysis of surface electromyography during epileptic and nonepileptic convulsive seizures

    DEFF Research Database (Denmark)

    Beniczky, S.; Conradsen, I.; Moldovan, M.

    2014-01-01

    , median frequency (MF), coherence, and duration of the seizures, of the clonic EMG discharges, and of the silent periods between the cloni. Based on wavelet analysis, we distinguished between a low-frequency component (LF 2-8 Hz) and a high-frequency component (HF 64-256 Hz). Results: Duration...... without rhythmic clonic movements....

  5. Lower motor neuron involvement examined by quantitative electromyography in amyotrophic lateral sclerosis

    DEFF Research Database (Denmark)

    Krarup, Christian

    2011-01-01

    in clinically non-involved muscles. The aim of the study was to determine the relative importance of ongoing (active) denervation, fasciculations, chronic partial denervation with reinnervation at weak effort and loss of motor units at maximal voluntary contraction (MVC) in ALS. Methods EMG was carried out...... with early ALS including clinically non-involved regions. These findings suggest that the maintenance of force is due to compensatory reinnervation in early disease and that this capacity may decline at later stages of ALS. Significance These findings support a recent consensus report (the Awaji criteria...

  6. Remodeling of motor units after nerve regeneration studied by quantitative electromyography

    DEFF Research Database (Denmark)

    Krarup, Christian; Boeckstyns, Michel; Ibsen, Allan

    2016-01-01

    different types of nerve repair. Methods: Reinnervation of muscle was compared clinically and electrophysiologically in complete median or ulnar nerve lesions with short gap lengths in the distal forearm repaired with a collagen nerve conduit (11 nerves) or nerve suture (10 nerves). Reestablishment of motor...

  7. Detecting Nasal Vowels in Speech Interfaces Based on Surface Electromyography.

    Directory of Open Access Journals (Sweden)

    João Freitas

    Full Text Available Nasality is a very important characteristic of several languages, European Portuguese being one of them. This paper addresses the challenge of nasality detection in surface electromyography (EMG based speech interfaces. We explore the existence of useful information about the velum movement and also assess if muscles deeper down in the face and neck region can be measured using surface electrodes, and the best electrode location to do so. The procedure we adopted uses Real-Time Magnetic Resonance Imaging (RT-MRI, collected from a set of speakers, providing a method to interpret EMG data. By ensuring compatible data recording conditions, and proper time alignment between the EMG and the RT-MRI data, we are able to accurately estimate the time when the velum moves and the type of movement when a nasal vowel occurs. The combination of these two sources revealed interesting and distinct characteristics in the EMG signal when a nasal vowel is uttered, which motivated a classification experiment. Overall results of this experiment provide evidence that it is possible to detect velum movement using sensors positioned below the ear, between mastoid process and the mandible, in the upper neck region. In a frame-based classification scenario, error rates as low as 32.5% for all speakers and 23.4% for the best speaker have been achieved, for nasal vowel detection. This outcome stands as an encouraging result, fostering the grounds for deeper exploration of the proposed approach as a promising route to the development of an EMG-based speech interface for languages with strong nasal characteristics.

  8. Central motor control failure in fibromyalgia: a surface electromyography study.

    Science.gov (United States)

    Casale, Roberto; Sarzi-Puttini, Piercarlo; Atzeni, Fabiola; Gazzoni, Marco; Buskila, Dan; Rainoldi, Alberto

    2009-07-01

    Fibromyalgia (FM) is characterised by diffuse musculoskeletal pain and stiffness at multiple sites, tender points in characteristic locations, and the frequent presence of symptoms such as fatigue. The aim of this study was to assess whether the myoelectrical manifestations of fatigue in patients affected by FM are central or peripheral in origin. Eight female patients aged 55.6 +/- 13.6 years (FM group) and eight healthy female volunteers aged 50.3 +/- 9.3 years (MCG) were studied by means of non-invasive surface electromyography (s-EMG) involving a linear array of 16 electrodes placed on the skin overlying the biceps brachii muscle, with muscle fatigue being evoked by means of voluntary and involuntary (electrically elicited) contractions. Maximal voluntary contractions (MVCs), motor unit action potential conduction velocity distributions (mean +/- SD and skewness), and the mean power frequency of the spectrum (MNF) were estimated in order to assess whether there were any significant differences between the two groups and contraction types. The motor pattern of recruitment during voluntary contractions was altered in the FM patients, who also showed fewer myoelectrical manifestations of fatigue (normalised conduction velocity rate of changes: -0.074 +/- 0.052%/s in FM vs -0.196 +/- 0.133%/s in MCG; normalised MNF rate of changes: -0.29 +/- 0.16%/s in FM vs -0.66 +/- 0.34%/s in MCG). Mean conduction velocity distribution and skewnesses values were higher (p fatigue in FM is the electrophysiological expression of muscle remodelling in terms of the prevalence of slow conducting fatigue-resistant type I fibres. As the only between-group differences concerned voluntary contractions, they are probably more related to central motor control failure than muscle membrane alterations, which suggests pathological muscle fibre remodelling related to altered suprasegmental control.

  9. One-Channel Surface Electromyography Decomposition for Muscle Force Estimation

    Directory of Open Access Journals (Sweden)

    Wentao Sun

    2018-05-01

    Full Text Available Estimating muscle force by surface electromyography (sEMG is a non-invasive and flexible way to diagnose biomechanical diseases and control assistive devices such as prosthetic hands. To estimate muscle force using sEMG, a supervised method is commonly adopted. This requires simultaneous recording of sEMG signals and muscle force measured by additional devices to tune the variables involved. However, recording the muscle force of the lost limb of an amputee is challenging, and the supervised method has limitations in this regard. Although the unsupervised method does not require muscle force recording, it suffers from low accuracy due to a lack of reference data. To achieve accurate and easy estimation of muscle force by the unsupervised method, we propose a decomposition of one-channel sEMG signals into constituent motor unit action potentials (MUAPs in two steps: (1 learning an orthogonal basis of sEMG signals through reconstruction independent component analysis; (2 extracting spike-like MUAPs from the basis vectors. Nine healthy subjects were recruited to evaluate the accuracy of the proposed approach in estimating muscle force of the biceps brachii. The results demonstrated that the proposed approach based on decomposed MUAPs explains more than 80% of the muscle force variability recorded at an arbitrary force level, while the conventional amplitude-based approach explains only 62.3% of this variability. With the proposed approach, we were also able to achieve grip force control of a prosthetic hand, which is one of the most important clinical applications of the unsupervised method. Experiments on two trans-radial amputees indicated that the proposed approach improves the performance of the prosthetic hand in grasping everyday objects.

  10. Electromyography Exposes Heterogeneity in Muscle Co-Contraction following Stroke

    Directory of Open Access Journals (Sweden)

    Caitlin L. Banks

    2017-12-01

    Full Text Available Walking after stroke is often described as requiring excessive muscle co-contraction, yet, evidence that co-contraction is a ubiquitous motor control strategy for this population remains inconclusive. Co-contraction, the simultaneous activation of agonist and antagonist muscles, can be assessed with electromyography (EMG but is often described qualitatively. Here, our goal is to determine if co-contraction is associated with gait impairments following stroke. Fifteen individuals with chronic stroke and nine healthy controls walked on an instrumented treadmill at self-selected speed. Surface EMGs were collected from the medial gastrocnemius (MG, soleus (SOL, and tibialis anterior (TA of each leg. EMG envelope amplitudes were assessed in three ways: (1 no normalization, (2 normalization to the maximum value across the gait cycle, or (3 normalization to maximal M-wave. Three co-contraction indices were calculated across each agonist/antagonist muscle pair (MG/TA and SOL/TA to assess the effect of using various metrics to quantify co-contraction. Two factor ANOVAs were used to compare effects of group and normalization for each metric. Co-contraction during the terminal stance (TSt phase of gait is not different between healthy controls and the paretic leg of individuals post-stroke, regardless of the metric used to quantify co-contraction. Interestingly, co-contraction was similar between M-max and non-normalized EMG; however, normalization does not impact the ability to resolve group differences. While a modest correlation is revealed between the amount of TSt co-contraction and walking speed, the relationship is not sufficiently strong to motivate further exploration of a causal link between co-contraction and walking function after stroke. Co-contraction does not appear to be a common strategy employed by individuals after stroke. We recommend exploration of alternative EMG analysis approaches in an effort to learn more about the causal

  11. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  12. Tattoo machines, needles and utilities.

    Science.gov (United States)

    Rosenkilde, Frank

    2015-01-01

    Starting out as a professional tattooist back in 1977 in Copenhagen, Denmark, Frank Rosenkilde has personally experienced the remarkable development of tattoo machines, needles and utilities: all the way from home-made equipment to industrial products of substantially improved quality. Machines can be constructed like the traditional dual-coil and single-coil machines or can be e-coil, rotary and hybrid machines, with the more convenient and precise rotary machines being the recent trend. This development has resulted in disposable needles and utilities. Newer machines are more easily kept clean and protected with foil to prevent crosscontaminations and infections. The machines and the tattooists' knowledge and awareness about prevention of infection have developed hand-in-hand. For decades, Frank Rosenkilde has been collecting tattoo machines. Part of his collection is presented here, supplemented by his personal notes. © 2015 S. Karger AG, Basel.

  13. Electroencephalogram–Electromyography Coupling Analysis in Stroke Based on Symbolic Transfer Entropy

    Directory of Open Access Journals (Sweden)

    Yunyuan Gao

    2018-01-01

    Full Text Available The coupling strength between electroencephalogram (EEG and electromyography (EMG signals during motion control reflects the interaction between the cerebral motor cortex and muscles. Therefore, neuromuscular coupling characterization is instructive in assessing motor function. In this study, to overcome the limitation of losing the characteristics of signals in conventional time series symbolization methods, a variable scale symbolic transfer entropy (VS-STE analysis approach was proposed for corticomuscular coupling evaluation. Post-stroke patients (n = 5 and healthy volunteers (n = 7 were recruited and participated in various tasks (left and right hand gripping, elbow bending. The proposed VS-STE was employed to evaluate the corticomuscular coupling strength between the EEG signal measured from the motor cortex and EMG signal measured from the upper limb in both the time-domain and frequency-domain. Results showed a greater strength of the bi-directional (EEG-to-EMG and EMG-to-EEG VS-STE in post-stroke patients compared to healthy controls. In addition, the strongest EEG–EMG coupling strength was observed in the beta frequency band (15–35 Hz during the upper limb movement. The predefined coupling strength of EMG-to-EEG in the affected side of the patient was larger than that of EEG-to-EMG. In conclusion, the results suggested that the corticomuscular coupling is bi-directional, and the proposed VS-STE can be used to quantitatively characterize the non-linear synchronization characteristics and information interaction between the primary motor cortex and muscles.

  14. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  15. Laryngeal electromyography-guided hyaluronic acid vocal fold injection for unilateral vocal fold paralysis: a prospective long-term follow-up outcome report.

    Science.gov (United States)

    Wang, Chen-Chi; Chang, Ming-Hong; Jiang, Rong-San; Lai, Hsiu-Chin; De Virgilio, Armando; Wang, Ching-Ping; Wu, Shang-Heng; Liu, Shi-An; Liang, Kai-Li

    2015-03-01

    Unilateral vocal fold paralysis (UVFP) is a common voice disorder that may cause glottal closure insufficiency with hoarseness of voice. Laryngeal electromyography (LEMG)-guided hyaluronic acid vocal fold (VF) injection has been proposed as a treatment option to improve glottal closure with a satisfactory short-term effect. To our knowledge, this study reports the first long-term follow-up result of this treatment modality. To present the long-term treatment results of LEMG-guided hyaluronic acid VF injection for UVFP. Prospective study of the treatment results of 74 patients who received LEMG-guided hyaluronic acid VF injection for UVFP at a tertiary referral medical center from March 2010 to February 2013. In the office-based procedure, 1.0 mL of hyaluronic acid was injected via a 26-gauge monopolar injectable needle electrode into paralyzed thyroarytenoid muscles by LEMG guidance. Various glottal closure evaluations such as normalized glottal gap area, maximal phonation time, phonation quotient, mean airflow rate, perceptual GRBAS (grade, roughness, breathiness, asthenia, strain) scale, and Voice Handicap Index were compared before and after injection using the nonparametric Wilcoxon signed rank test within 1 month, at 6 months, and at the last follow-up examination. Sixty patients had been followed up for at least 6 months. Forty-four patients received only 1 injection, and 16 patients received repeated injections (2 injections for 13 patients and 3 for 3 patients). All the glottal closure parameters improved significantly (P injection and 16 (22%) who received repeated injections did not require another treatment after long-term follow-up. Laryngeal electromyography-guided hyaluronic acid VF injection is an option for treating UVFP with satisfactory results.

  16. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  17. Tensor veli palatini electromyography for monitoring Eustachian tube rehabilitation in otitis media.

    Science.gov (United States)

    Picciotti, P M; Della Marca, G; D'Alatri, L; Lucidi, D; Rigante, M; Scarano, E

    2017-05-01

    The pathogenesis of otitis media is related to Eustachian tube dysfunction. The tensor veli palatini muscle actively opens the Eustachian tube and promotes middle-ear ventilation. This study describes a technique for paratubal electromyography that uses a surface, non-invasive electrode able to record tensor veli palatini muscle activity during swallowing. Twenty otitis media patients and 10 healthy patients underwent tensor veli palatini electromyography. Activity of this muscle before and after Eustachian tube rehabilitation was also assessed. In 78.5 per cent of patients, the electromyography duration phase and/or amplitude were reduced in the affected side. The muscle action potential was impaired in all patients who underwent Eustachian tube rehabilitation. This study confirmed that Eustachian tube muscle dysfunction has a role in otitis media pathogenesis and showed that muscle activity increases after Eustachian tube rehabilitation therapy.

  18. The risk of hematoma following extensive electromyography of the lumbar paraspinal muscles

    Science.gov (United States)

    London, Zachary; Quint, Douglas J.; Haig, Andrew J.; Yamakawa, Karen S. J.

    2012-01-01

    Introduction The purpose of this study is to provide a controlled trial looking at the risk of paraspinal hematoma formation following extensive paraspinal muscle electromyography. Methods 54 subjects ages 55-80 underwent MRI of the lumbar spine before or shortly after electromyography using the paraspinal mapping technique. A neuroradiologist, blinded to the temporal relationship between the EMG and MRI, reviewed the MRIs to look for hematomas in or around the paraspinal muscles. Results Two MRIs demonstrated definite paraspinal hematomas, while 10 were found to have possible hematomas. All hematomas were hematoma and either the timing of the EMG or the use of aspirin or other non-steroidal anti-inflammatory drugs. Discussion Paraspinal electromyography can be considered safe in the general population and those taking non-steroidal anti-inflammatory drugs. PMID:22644875

  19. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  20. Experiences with a new breast localisation needle

    International Nuclear Information System (INIS)

    Hergan, K.; Amann, T.; Doringer, W.; Hollenstein, P.

    1990-01-01

    In view of the increasing number of biopsies of non-palpable lesions of the female breast we found an ideal localisation system in the Hawkins breast localisation needle. Localisation was successful without technical problems in 31 out of 34 patients. The special advantages of the needle are its stability in position and excellent manoeverability due to the construction of the needle. The very simple handling of the needle is an advantage not only for the radiologist but also for the surgeon. (orig.) [de

  1. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  2. How needless are Buffon's needles?

    International Nuclear Information System (INIS)

    Babović, Miloš; Babović, Vukota

    2013-01-01

    The study of statistical physics requires introductory preparation regarding probability theory. Understanding its fundamental concepts (randomness, distributions, fluctuations), and some experience in application of the basic concepts of statistics can be obtained in several ways. We found that the basic training in probability and statistics needed for physics and engineering study can be achieved by focusing on Buffon's needle problem. We believe this approach could help university specialists make study more efficient when probability and statistics play an important role. Buffon's experiment, with its convincing simplicity and flexibility, as well as its attractiveness, is in our opinion a useful tool in physics education at university level. (paper)

  3. Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?

    Science.gov (United States)

    Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M

    2009-01-01

    Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.

  4. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  5. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  6. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  7. Observations of needle-tissue interactions

    NARCIS (Netherlands)

    Misra, Sarthak; Reed, Kyle B.; Ramesh, K.T.; Okamura, Allison M.

    2009-01-01

    Needles with asymmetric bevel tips naturally bend when they are inserted into soft tissue. In this study, we present an analytical model for the loads developed at the bevel tip during needle-tissue interaction. The model calculates the loads based on the geometry of the bevel edge and gel material

  8. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site) on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Science.gov (United States)

    Loyeung, Bertrand Y. K.; Cobbin, Deirdre M.

    2013-01-01

    Introduction. In traditional Chinese acupuncture, needle sensation (deqi) is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP) on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP) maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site. PMID:24159337

  9. [Professor WU Zhongchao's experience of penetration needling].

    Science.gov (United States)

    Zhang, Ning; Wang, Bing; Zhou, Yu

    2016-08-12

    Professor WU Zhongchao has unique application of penetration needling in clinical treatment. Professor WU applies penetration needling along meridians, and the methods of penetration needling include self-meridian penetration, exterior-interior meridian penetration, identical-name meridian penetration, different meridian penetration. The meridian differentiation is performed according to different TCM syndromes, locations and natures of diseases and acupoint nature, so as to make a comprehensive assessment. The qi movement during acupuncture is focused. In addition, attention is paid on anatomy and long-needle penetration; the sequence and direction of acupuncture is essential, and the reinforcing and reducing methods have great originality, presented with holding, waiting, pressing and vibrating. Based on classical acupoint, the acupoint of penetration needling is flexible, forming unique combination of acupoints.

  10. Muscle fatigue and contraction intensity modulates the complexity of surface electromyography.

    Science.gov (United States)

    Cashaback, Joshua G A; Cluff, Tyler; Potvin, Jim R

    2013-02-01

    Nonlinear dynamical techniques offer a powerful approach for the investigation of physiological time series. Multiscale entropy analyses have shown that pathological and aging systems are less complex than healthy systems and this finding has been attributed to degraded physiological control processes. A similar phenomenon may arise during fatiguing muscle contractions where surface electromyography signals undergo temporal and spectral changes that arise from the impaired regulation of muscle force production. Here we examine the affect of fatigue and contraction intensity on the short and long-term complexity of biceps brachii surface electromyography. To investigate, we used an isometric muscle fatigue protocol (parsed into three windows) and three contraction intensities (% of maximal elbow joint moment: 40%, 70% and 100%). We found that fatigue reduced the short-term complexity of biceps brachii activity during the last third of the fatiguing contraction. We also found that the complexity of surface electromyography is dependent on contraction intensity. Our results show that multiscale entropy is sensitive to muscle fatigue and contraction intensity and we argue it is imperative that both factors be considered when evaluating the complexity of surface electromyography signals. Our data contribute to a converging body of evidence showing that multiscale entropy can quantify subtle information content in physiological time series. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Electromyography in the assessment and therapy of lower urinary tract dysfunction in adults

    DEFF Research Database (Denmark)

    Krhut, Jan; Zachoval, Roman; Rosier, Peter F W M

    2018-01-01

    AIM: To present the teaching module "Electromyography in the assessment and therapy of lower urinary tract dysfunction in adults." This teaching module embodies a presentation, in combination with this manuscript. This manuscript serves as a scientific background review; the evidence base made...

  12. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Topal, U.; Berkman, Yahya M.

    2005-01-01

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ 2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  14. Sugar export limits size of conifer needles

    DEFF Research Database (Denmark)

    Rademaker, Hanna; Zwieniecki, Maciej A.; Bohr, Tomas

    2017-01-01

    Plant leaf size varies by more than three orders of magnitude, from a few millimeters to over one meter. Conifer leaves, however, are relatively short and the majority of needles are no longer than 6 cm. The reason for the strong confinement of the trait-space is unknown. We show that sugars...... does not contribute to sugar flow. Remarkably, we find that the size of the active part does not scale with needle length. We predict a single maximum needle size of 5 cm, in accord with data from 519 conifer species. This could help rationalize the recent observation that conifers have significantly...

  15. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  16. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  17. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-01-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  18. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-02-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  19. [Discussion on needling sensation, arrival of qi and needling response (Deqi)].

    Science.gov (United States)

    Zhang, Fang; Wang, Hong-Du

    2012-12-01

    The current appointed teaching material of Science of Acupuncture and Moxibustion holds that there is no difference among the needling sensation, arrival of qi and needling response. However, the author has a different understanding. Therefore, Neijing (Internal Classic), its annotation, exposition and understandings of ancient and modern famous experts are cited to analyze their meanings. And the result indicates that the needling sensation is subjective feelings and perceived responses of doctors and patients. Arrival of qi is the healing process of the organ through activating the anti-pathogenic qi to expel the pathogens. The needling response is the final aim of acupuncture therapy. Thus, the meaning of needling sensation, arrival of qi, and needling response are different. And an accurate understanding can better guide acupuncture treatment.

  20. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  1. [Electromyography Analysis of Rapid Eye Movement Sleep Behavior Disorder].

    Science.gov (United States)

    Nakano, Natsuko; Kinoshita, Fumiya; Takada, Hiroki; Nakayama, Meiho

    2018-01-01

    Polysomnography (PSG), which records physiological phenomena including brain waves, breathing status, and muscle tonus, is useful for the diagnosis of sleep disorders as a gold standard. However, measurement and analysis are complex for several specific sleep disorders, such as rapid eye movement (REM) sleep behavior disorder (RBD). Usually, brain waves during REM sleep indicate an awakening pattern under relaxed conditions of skeletal and antigravity muscles. However, these muscles are activated during REM sleep when patients suffer from RBD. These activated muscle movements during REM, so-called REM without atonia (RWA) recorded by PSG, may be related to a neurodegenerative disease such as Parkinson's disease. Thus, careful analysis of RWA is significant not only physically, but also clinically. Commonly, manual viewing measurement analysis of RWA is time-consuming. Therefore, quantitative studies on RWA are rarely reported. A software program, developed from Microsoft Office Excel ® , was used to semiautomatically analyze the RWA ratio extracted from PSG to compare with manual viewing measurement analysis. In addition, a quantitative muscle tonus study was carried out to evaluate the effect of medication on RBD patients. Using this new software program, we were able to analyze RWA on the same cases in approximately 15 min as compared with 60 min in the manual viewing measurement analysis. This software program can not only quantify RWA easily but also identify RWA waves for either phasic or tonic bursts. We consider that this software program will support physicians and scientists in their future research on RBD. We are planning to offer this software program for free to physicians and scientists.

  2. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  3. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  4. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  5. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  6. Mechanomyography versus Electromyography, in monitoring the muscular fatigue

    Directory of Open Access Journals (Sweden)

    Tarata Mihai T

    2003-02-01

    Full Text Available Abstract Background The use of the mechanomyogram (MMG which detects muscular vibrations generated by fused individual fiber twitches has been refined. The study addresses a comparison of the MMG and surface electromyogram (SEMG in monitoring muscle fatigue. Methods The SEMG and MMG were recorded simultaneously from the same territory of motor units in two muscles (Biceps, Brachioradialis of the human (n = 18, during sustained contraction at 25 % MVC (maximal voluntary contraction. Results The RMS (root mean square of the SEMG and MMG increased with advancing fatigue; MF (median frequency of the PSD (power density spectra progressively decreased from the onset of the contraction. These findings (both muscles, all subjects, demonstrate both through the SEMG and MMG a central component of the fatigue. The MF regression slopes of MMG were closer to each other between men and women (Biceps 1.55%; Brachialis 13.2% than were the SEMG MF slopes (Biceps 25.32%; Brachialis 17.72%, which shows a smaller inter-sex variability for the MMG vs. SEMG. Conclusion The study presents another quantitative comparison (MF, RMS of MMG and SEMG, showing that MMG signal can be used for indication of the degree of muscle activation and for monitoring the muscle fatigue when the application of SEMG is not feasible (chronical implants, adverse environments contaminated by electrical noise.

  7. Generation of synthetic surface electromyography signals under fatigue conditions for varying force inputs using feedback control algorithm.

    Science.gov (United States)

    Venugopal, G; Deepak, P; Ghosh, Diptasree M; Ramakrishnan, S

    2017-11-01

    Surface electromyography is a non-invasive technique used for recording the electrical activity of neuromuscular systems. These signals are random, complex and multi-component. There are several techniques to extract information about the force exerted by muscles during any activity. This work attempts to generate surface electromyography signals for various magnitudes of force under isometric non-fatigue and fatigue conditions using a feedback model. The model is based on existing current distribution, volume conductor relations, the feedback control algorithm for rate coding and generation of firing pattern. The result shows that synthetic surface electromyography signals are highly complex in both non-fatigue and fatigue conditions. Furthermore, surface electromyography signals have higher amplitude and lower frequency under fatigue condition. This model can be used to study the influence of various signal parameters under fatigue and non-fatigue conditions.

  8. Electromyography-Guided Botulinum Toxin Injection Into the Cricothyroid Muscles in Bilateral Vocal Fold Abductor Paralysis

    OpenAIRE

    Sahin, Mustafa; Aydogdu, Ibrahim; Akyildiz, Serdar; Erdinc, Munevver; Ozturk, Kerem; Ogut, Fatih

    2016-01-01

    Objectives Bilateral vocal fold abductor paralysis (BVFAP) both deteriorates quality of life and may cause life-threatening respiratory problems. The aim of this study was to reduce respiratory symptoms in BVFAP patients using cricothyroid (CT) botulinum toxin (BTX) injection. Methods Before and 2 weeks and 4 months after bilateral BTX injection into the CT muscles under electromyography; alterations in respiratory, acoustic, aerodynamic and quality of life parameters were evaluated in BVFAP ...

  9. Recurrent intractable hiccups treated by cervical phrenic nerve block under electromyography: report of a case.

    Science.gov (United States)

    Sa, Young Jo; Song, Dae Heon; Kim, Jae Jun; Kim, Young Du; Kim, Chi Kyung; Moon, Seok Whan

    2015-11-01

    Intractable or persistent hiccups require intensive or invasive treatments. The use of a phrenic nerve block or destructive treatment for intractable hiccups has been reported to be a useful and discrete method that might be valuable to patients with this distressing problem and for whom diverse management efforts have failed. We herein report a successful treatment using a removable and adjustable ligature for the phrenic nerve in a patient with recurrent and intractable hiccups, which was employed under the guidance of electromyography.

  10. Microstructural characterization, formation mechanism and fracture behavior of the needle δ phase in Fe–Ni–Cr type superalloys with high Nb content

    Energy Technology Data Exchange (ETDEWEB)

    Ning, Yongquan, E-mail: luckyning@nwpu.edu.cn [School of Materials Science & Engineering, Northwestern Polytechnical University, Xi' an 710072 (China); Huang, Shibo [Anshan Iron & Steel Group Corporation Bayuquan Subsidiary Company, Bayuquan 115007 (China); Fu, M.W. [Department of Mechanical Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Dong, Jie [Inspection & Research Institute of Boiler & Pressure Vessel of Jiangxi Province, Nanchang 330029 (China)

    2015-11-15

    Microstructural characterization, formation mechanism and fracture behavior of the needle δ phase in Fe–Ni–Cr type superalloys with high Nb content (GH4169, equivalent to Inconel 718) have been quantitatively investigated in this research. The typical microstructures of δ phases with the stick, mixed and needle shapes obviously present in Inconel 718 after the isothermal upsetting at the temperature of 980–1060 °C with the initial strain rate of 10{sup −3}–10{sup −1} s{sup −1}. It is found that the shape of the δ phase has a great effect on the mechanical properties of the alloy, viz., the stick δ phase behaves good plasticity and the needle δ phase has good strength. In addition, the needle δ phase can be used to control the grain size as it can prevent grain growth. The combined effect of the localized necking and microvoid coalescence leads to the final ductile fracture of the GH4169 components with the needle δ phase. Both dislocation motion and atom diffusion are the root-cause for the needle δ phase to be firstly separated at grain boundary and then at sub-boundary. The formation mechanism of the needle δ phase is the new finding in this research. Furthermore, it is the primary mechanism for controlling the needle δ phase in Fe–Ni–Cr type superalloys with high Nb content. - Highlights: • Shape of the δ phase takes great effect on mechanical property. • Needle δ phase plays a great role to prevent grain growth. • Needle δ phase can enhance the fracture strength. • Microstructure mechanism of the needle δ phase has been investigated. • Fracture behavior of the needle δ phase has been studied.

  11. Diagnosis of cauda equina abnormalities by using electromyography, discography, and epidurography in dogs

    International Nuclear Information System (INIS)

    Sisson, A.F.; LeCouteur, R.A.; Ingram, J.T.; Park, R.D.; Child, G.

    1992-01-01

    Electromyography (EMG), L7-S1 discography and epidurography were investigated in 15 dogs with clinical signs of cauda equina dysfunction and in 7 control dogs without such clinical signs. Electromyography of paraspinal and pelvic limb muscles was done in 13 of 15 affected dogs. An L7-S1 discogram followed by an epidurogram was performed in all 22 dogs using 20% iopamidol. Results of discograms, epidurograms, and gross necropsy examinations were normal in six of seven control dogs. The one dog in which these studies were abnormal had a mild L7-S1 disc protrusion that did not result in nerve root compression at necropsy. Electromyographic analysis was 100% accurate in predicting the presence or absence of cauda equina disease. None of the results of discograms were falsely negative. Twelve of 15 discograms in clinically affected dogs indicated dorsal disc protrusion, but 2 of these protrusions were found to be noncompressive at surgery (13% error). Abnormal epidurograms occurred in 9 of 15 clinically affected dogs. There was one false positive and two false negatives (20% error). Electromyography was a sensitive screening technique for the presence of cauda equina disease. Discography may be more sensitive for detection of L7-S1 disc protrusion than epidurography. An abnormal radiographic contrast study of the cauda equina may only be useful when combined with an abnormal EMG

  12. Relationship Between Laryngeal Electromyography and Video Laryngostroboscopy in Vocal Fold Paralysis.

    Science.gov (United States)

    Maamary, Joel A; Cole, Ian; Darveniza, Paul; Pemberton, Cecilia; Brake, Helen Mary; Tisch, Stephen

    2017-09-01

    The objective of this study was to better define the relationship of laryngeal electromyography and video laryngostroboscopy in the diagnosis of vocal fold paralysis. Retrospective diagnostic cohort study with cross-sectional data analysis METHODS: Data were obtained from 57 patients with unilateral vocal fold paralysis who attended a large tertiary voice referral center. Electromyographic findings were classified according to recurrent laryngeal nerve, superior laryngeal nerve, and high vagal/combined lesions. Video laryngostroboscopy recordings were classified according to the position of the immobile fold into median, paramedian, lateral, and a foreshortened/hooded vocal fold. The position of the paralyzed vocal fold was then analyzed according to the lesion as determined by electromyography. The recurrent laryngeal nerve was affected in the majority of cases with left-sided lesions more common than right. Vocal fold position differed between recurrent laryngeal and combined vagal lesions. Recurrent laryngeal nerve lesions were more commonly associated with a laterally displaced immobile fold. No fold position was suggestive of a combined vagal lesion. The inter-rater reliability for determining fold position was high. Laryngeal electromyography is useful in diagnosing neuromuscular dysfunction of the larynx and best practice recommends its continued implementation along with laryngostroboscopy. While recurrent laryngeal nerve lesions are more likely to present with a lateral vocal fold, this does not occur in all cases. Such findings indicate that further unknown mechanisms contribute to fold position in unilateral paralysis. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  13. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  14. Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use

    Science.gov (United States)

    2016-06-01

    Orofacial Pain Graduate...JOURNAL PHYSICAL PROPERTIES OF ACUPUNCTURE NEEDLES: DO DISPOSABLE ACUPUNCTURE NEEDLES BREAK WITH NORMAL USE? James Kyle Vick DDS, Orofacial Pain ...MS CAPT, DC, USN Orofacial Pain Department Head Naval Postgraduate Dental School vi    TABLE OF CONTENTS GUIDELINE I. TITLE

  15. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  16. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  17. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  18. Effect of Blinding With a New Pragmatic Placebo Needle

    Science.gov (United States)

    Liu, Baoyan; Xu, Huanfang; Ma, Rui; Mo, Qian; Yan, Shiyan; Liu, Zhishun

    2014-01-01

    Abstract Placebo control is a useful method for determining the efficacy of a therapy. In acupuncture researches, the preferred method for placebo control is acupuncture using a placebo needle that has a blunt tip and achieves no skin penetration. We performed a crossover study to validate the blinding effect of a new type of placebo needle. Sixty volunteers were randomized to receive acupuncture using 2 types of needles with different sequences: sequence AB, involving first the pragmatic placebo needle and then the real needle, and sequence BA, in a reverse order. Placebo acupuncture was performed by administering the placebo needle through an adhesive pad without skin penetration on the acupoints LI4, RN12, BL25, and BL36. Real acupuncture was performed by needling through the pad and penetrating the skin to 15 mm using a real needle on the same acupoints. The acupuncture was administered every other day with 3 sessions for 1 type of needle. The primary outcome was the perception of needle penetration. Besides degree of acupuncture pain, type, and degree of needle sensation, needle acceptability and factors influencing the subject blinding effect were assessed. Needle penetration was felt by 100%, 90% (54/60), 88.3% (53/60), and 95% (57/60) of volunteers receiving placebo acupuncture and 98.3% (59/60), 96.7% (58/60), 95% (57/60), and 95% (57/60) of volunteers receiving real acupuncture on LI4, RN12, BL25, and BL36, respectively. Differences of the volunteers’ perception of needle penetration between the placebo needle and real needle were not significant for the 4 acupoints (all P > 0.05). Volunteers experienced fewer distension sensations (P = 0.01), a lower degree of needle sensation (P = 0.007), and less pain (P = 0.006) during placebo acupuncture than during real acupuncture. The placebo needle was more easily accepted than the real needle (OR = 1.63, 95% CI, 1.01–2.64). The influences of age, sex, educational level, acupuncture

  19. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  20. Spruce needles used as radioecological biotracers

    International Nuclear Information System (INIS)

    Seidel, C.; Gruber, V.; Baumgartner, A.

    2009-01-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: 137 Cs, 40 K, 210 Pb, 226 Ra, 228 Ra, 238 U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  1. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  2. [King Injo's disease and burnt needle therapy].

    Science.gov (United States)

    Kim, In-Sook

    2004-12-01

    This paper investigates an interrelationship between burnt needle therapy and King Injo's disease. From 1633 (Year 11 in King Injo's reign) to May 5, 1649 (Year 27 in King Injo's reign), right before his death, King Injo was treated with burnt needles by Yi Hyeongik, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have?Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon ear, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease. The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong derived from her mother, Queen Mother Inmok. Moral justification for King Injo's coup was Gwanghaegun or Prince Gwanghae's immoral conduct toward Queen Mothe Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant rebellions and treasons threatened King Injo. The king suspected that Queen Mother

  3. King Injo's Disease and Burnt Needle Therapy

    Directory of Open Access Journals (Sweden)

    KIM In-Sook

    2004-12-01

    Full Text Available This paper investigates an interrelationship between burnt needle therapy(번침 and King Injo'sdisease. From 1633 (Year 11 in King Injo's reign to May 5, 1649 (Year 27 King in Injo's reign, right before his death, King Injo(인조 was treated with burnt needles by Yi Hyeongik(이형익, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have? Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon era, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease.  The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong(정명공주 derived from her mother, Queen Mother Inmok(인목대비. Moral justification for King Injo's coup was Gwanghaegun(광해군 or Prince Gwanghae's immoral conduct toward Queen Mother Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant

  4. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  5. HIFU Transducer Characterization Using a Robust Needle Hydrophone

    Science.gov (United States)

    Howard, Samuel M.; Zanelli, Claudio I.

    2007-05-01

    A robust needle hydrophone has been developed for HIFU transducer characterization and reported on earlier. After a brief review of the hydrophone design and performance, we demonstrate its use to characterize a 1.5 MHz, 10 cm diameter, F-number 1.5 spherically focused source driven to exceed an intensity of 1400 W/cm2at its focus. Quantitative characterization of this source at high powers is assisted by deconvolving the hydrophone's calibrated frequency response in order to accurately reflect the contribution of harmonics generated by nonlinear propagation in the water testing environment. Results are compared to measurements with a membrane hydrophone at 0.3% duty cycle and to theoretical calculations, using measurements of the field at the source's radiating surface as input to a numerical solution of the KZK equation.

  6. Analysis of the NovoTwist pen needle in comparison with conventional screw-thread needles.

    Science.gov (United States)

    Aye, Tandy

    2011-11-01

    Administration of insulin via a pen device may be advantageous over a vial and syringe system. Hofman and colleagues introduce a new insulin pen needle, the NovoTwist, to simplify injections to a small group of children and adolescents. Their overall preferences and evaluation of the handling of the needle are reported in the study. This new needle has the potential to ease administration of insulin via a pen device that may increase both the use of a pen device and adherence to insulin therapy. © 2011 Diabetes Technology Society.

  7. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  8. Effect of ponderosa pine needle litter on grass seedling survival.

    Science.gov (United States)

    Burt R. McConnell; Justin G. Smith

    1971-01-01

    Hard fescue survival rates were followed for 6 years on four different pine needle treatment plots. Needle litter had a significant effect on initial survival of fescue seedlings, but subsequent losses undoubtedly resulted from the interaction of many factors.

  9. [Evaluation of swallowing function with surface electromyography before and after tonsillectomy].

    Science.gov (United States)

    Gürkan, Emre; Veyseller, Bayram; Açıkalın, Reşit Murat; Elbistanlı, Suphi; Yurtsever, Serveren; Acar, Hürtan

    2011-01-01

    In this study, we evaluated the swallowing function with surface electromyography before and after tonsillectomy. Twenty patients (12 males, 8 females; mean age 23.8 years; range 17 to 30 years) who had tonsillectomy indication as study group, and 10 healthy individuals (8 males, 2 females; mean age 26 years; range 18 to 35 years) as control group were included in this prospective study between October 2008 and February 2009. Due to their significant role on oral and faringeal phases of swallowing; the surface electromyography prosedure is performed on the masseter muscle, the submental-submandibular muscle group and the infrahyoid muscles to measure their electrical activity and duration of contraction. For this purpose, single swallow and continuous drinking of 100 cc water tests were applied to each patient preoperatively and; in the postoperative 1st week and the 1st month. The preoperative duration of drinking periods were significanly longer in the study group compared to the control group (p<0.05). At the end of the first postoperative week the duration of drinking 100 cc water test was significantly longer than the preoperative mean of the study group (p<0.05). After one month single- swallow durations of study group were significantly shorter then the preoperative mean (p<0.05). The electrical activity of the masseter and infrahyoid muscles were significantly higher in study group compared with control group (p<0.05). The close proximity of the surgical area to the muscles affects swallowing after tonsillectomy. The surface electromyography is a simple, non-invasive and reliable method for postoperative evaluation of the swallowing functions of the throat muscles and thereby allows monitoring of the recovery and functional improvement of these muscles.

  10. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    Science.gov (United States)

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  11. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  12. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  13. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho

    2017-01-30

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  14. The Single Needle Lockstitch Machine. Module 1.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on parts of the machine, one in a series on the single needle lockstitch sewing machine for student self-study, contains eight sections. Each section contains the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  15. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Patients and Methods: This is a consecutive 9-year analysis of patients with peripheral lymphadenopathy. All the patients had fine needle aspiration. Smears were made, fixed in 95% alcohol and stained with hematoxylin and eosin and Zeihl Neelsen stains. Results: 48 patients, 31 males and 17 females, were analyzed.

  16. Acylated flavonol glycosides from Larix needles

    NARCIS (Netherlands)

    Niemann, Gerard J.

    2006-01-01

    Kaempferol-3-p-coumarylglucoside (KCG) was isolated from ether fractions of acetone-extracted freeze-dried needles of all larch species investigated. In each case, KCG was found as one of the main flavonoids, whereas often a variety of closely related, acylated flavonoids was present in either

  17. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho; Perez, Jose E.; Ivanov, Yurii; Bertoncini, Andrea; Liberale, Carlo; Kosel, Jü rgen

    2017-01-01

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  18. Relationship between needle phobia and dental anxiety

    NARCIS (Netherlands)

    Majstorovic, M.; Veerkamp, J.S.J.

    2004-01-01

    Purpose: This cross-sectional study aimed to explain the nature of needle phobia and its relationship in dental phobic children with evidence on age-related differences. Methods: The study used 2,865 patients (52% boys, 48% girls), 4 to 11 years old (mean=7.18 years). The patient sample included

  19. Rooting of needle fascicles from western white pine seedlings

    Science.gov (United States)

    Ramond J. Hoff; Geral I. McDonald

    1968-01-01

    In one test, 45 out of 318 (14 percent) needle fascicles from 2-year-old seedlings of Pinus monticola Dougl. were rooted. Eight of the needle fascicles produced shoot growth. In another test, 392 out of 742 (53 percent) needle fascicles were rooted, but none of these produced shoot growth.

  20. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to...

  1. Exploring needle anxiety among students attending a Nigerian ...

    African Journals Online (AJOL)

    Needle anxiety, a form of specific phobia refers to an intense fear of needles used for various medical procedures. It may result in the avoidance of such needle-involving procedures like intramuscular injections or vaccinations. About 4-8% of children and adolescents are said to generally suffer some form of anxiety.

  2. Robotic needle steering: design, modeling, planning, and image guidance

    NARCIS (Netherlands)

    Cowan, Noah J.; Goldberg, Ken; Chirikjian, Gregory S.; Fichtinger, Gabor; Alterovitz, Ron; Reed, Kyle B.; Kallem, Vinutha; Misra, Sarthak; Park, Wooram; Okamura, Allison M.; Rosen, Jacob; Hannaford, Blake; Satava, Richard M.

    2010-01-01

    This chapter describes how advances in needle design, modeling, planning, and image guidance make it possible to steer flexible needles from outside the body to reach specified anatomical targets not accessible using traditional needle insertion methods. Steering can be achieved using a variety of

  3. Measurement of tritium in tissue free water of pine needles

    International Nuclear Information System (INIS)

    Zheng Xiaomin; Wu Zongmei

    1993-01-01

    Tissue Free Water (TFW) of pine needles is separated out through azeotropic distillation of pine needles and toluene. Recovery ratio of TFW is 90%. Tritium activity in the needles is 1.8 Bq/L(H 2 O), which is of the same level with tritiated water vapour (HTO) in atmosphere during the corresponding period

  4. [Stiletto needle and needle-knife for influence of gravity index in treating knee osteoarthritis].

    Science.gov (United States)

    Gu, Li-Jun; Zhang, Bin; Li, Wen-Hua; Tang, Yan; Dong, Fu-Hui

    2017-12-25

    To explore stiletto needle and needle-knife for influence of double sufficient weight in treating knee osteoarthritis patients. One hundred and thirteen early and medium term knee osteoarthritis patients were randomly divided into three groups, including stiletto needle group(38 cases), needle-knife group (38 cases) and voltaren group (37 cases). In stiletto needle group, there were 13 males and 25 females with an average of(55.87±7.72) years old, treated by stiletto needle once a week, and 2 weeks were a course; there were 11 males and 27 females in needle-knife group with an average of(57.11±7.07) years old, treated by acupotome once a week, and 2 weeks were a course; there were 12 males and 25 females in voltaren group with an average age of(57.62±8.08) years old, treated by votalin emulsion smearing 3 to 5 cm on painful area of knee joint, three times a day for 2 weeks; 36 patients in normal group, including 11 males and 25 females with a mean age of (55.28±7.55) years old, treated with nothing. Gravitational four lattice used to measure bipedal back and forth load before and after treatment in further observe weight-bearing situation among three groups, d value, which was the distance from center of gravity to original point, was measured as a obvervational index, JOA score was used to evaluate clinical effect. Five patients were fall out, including 2 patients in stiletto needle group, 2 patients in needle-knife group and 1 patient in voltaren group. Other 108 patients were followed-up from 28 to 35 d with an average of 30 d, and without untoward effect. There was significant difference in d value between treatment group and control group at 1 month after treatment( P 0.05), and d value was decreased before treatment than that of after treatment. There was no significant difference in JOA score among treatment group after treatment at 1 month( P 0.05) after treatment at 1 month. Stiletto needle, needle-knife and voltaren for the treatment of knee

  5. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  6. [Deep needling and shallow needling at three acupoints around ear for subjective tinnitus: a randomized controlled trial].

    Science.gov (United States)

    Yin, Tao; Ni, Jinxia; Zhu, Wenzeng

    2015-10-01

    To compare the effective differences between deep needling and shallow needling at three acupoints around ear for subjective tinnitus. Fifty patients with subjective tinnitus were randomized divided into a deep needling group and a shallow needling group, 25 cases in each group. Twenty-two patients in the deep needling group and 20 patients in the shallow needling group were brought into statistic in the end. In the two groups, the three acupoints around ear and distal acupoints were both selected. The acupoints of the affected side such as Yifeng (TE 17), Tinghui (GB 2), Ermen (TE 21), Zhigou (TE 6), Zhongzhu (TE 3) and Hegu (LI 4) were adopted. Yifeng (TE 17), Tinghui (GB 2) and Ermen (TE 21) were acupunctured 30-38 mm in the deep needling group and 15-20 mm in the shallow needling group. The other acupoints were conventionally acupunctured in the two groups. The needles were retained for 30 min,once a day and five times a week for all patients. The treatment was continuously for 4 weeks in the two groups. Tinnitus handicap inventory (THI) scores, tinnitus grades and visual analogue scale (VAS) for tinnitus sound levels were observed before and after treatment, and the effects of the two groups were compared. The total effective rate in the deep needling group was 59.1% (13/22), and it was better than 20.0% (4/20) in the shallow needling group (P deep needling, group, the THI score, tinnitus grade and the VAS score were improved than those before treatment (all P shallow needling group, the three above indices before and after treatment were not different in statistical significance (all P > 0.05). After treatment, all the three indices in the deep needling group were superior to those in the shallow needling group (all P shallow needling at the three acupoints.

  7. Impact of Functional Appliances on Muscle Activity: A Surface Electromyography Study in Children

    Science.gov (United States)

    Woźniak, Krzysztof; Piątkowska, Dagmara; Szyszka-Sommerfeld, Liliana; Buczkowska-Radlińska, Jadwiga

    2015-01-01

    Background Electromyography (EMG) is the most objective tool for assessing changes in the electrical activity of the masticatory muscles. The purpose of the study was to evaluate the tone of the masseter and anterior temporalis muscles in growing children before and after 6 months of treatment with functional removable orthodontic appliances. Material/Methods The sample conisted of 51 patients with a mean age 10.7 years with Class II malocclusion. EMG recordings were performed by using a DAB-Bluetooth instrument (Zebris Medical GmbH, Germany). Recordings were performed in mandibular rest position, during maximum voluntary contraction (MVC), and during maximum effort. Results The results of the study indicated that the electrical activity of the muscles in each of the clinical situations was the same in the group of girls and boys. The factor that determined the activity of the muscles was their type. In mandibular rest position and in MVC, the activity of the temporalis muscles was significantly higher that that of the masseter muscels. The maximum effort test indicated a higher fatigue in masseter than in temporalis muscles. Conclusions Surface electromyography is a useful tool for monitoring muscle activity. A 6-month period of functional therapy resulted in changes in the activity of the masticatory muscles. PMID:25600247

  8. Reliability of surface electromyography in the assessment of paraspinal muscle fatigue: an updated systematic review.

    Science.gov (United States)

    Mohseni Bandpei, Mohammad A; Rahmani, Nahid; Majdoleslam, Basir; Abdollahi, Iraj; Ali, Shabnam Shah; Ahmad, Ashfaq

    2014-09-01

    The purpose of this study was to review the literature to determine whether surface electromyography (EMG) is a reliable tool to assess paraspinal muscle fatigue in healthy subjects and in patients with low back pain (LBP). A literature search for the period of 2000 to 2012 was performed, using PubMed, ProQuest, Science Direct, EMBASE, OVID, CINAHL, and MEDLINE databases. Electromyography, reliability, median frequency, paraspinal muscle, endurance, low back pain, and muscle fatigue were used as keywords. The literature search yielded 178 studies using the above keywords. Twelve articles were selected according to the inclusion criteria of the study. In 7 of the 12 studies, the surface EMG was only applied in healthy subjects, and in 5 studies, the reliability of surface EMG was investigated in patients with LBP or a comparison with a control group. In all of these studies, median frequency was shown to be a reliable EMG parameter to assess paraspinal muscles fatigue. There was a wide variation among studies in terms of methodology, surface EMG parameters, electrode location, procedure, and homogeneity of the study population. The results suggest that there seems to be a convincing body of evidence to support the merit of surface EMG in the assessment of paraspinal muscle fatigue in healthy subject and in patients with LBP. Copyright © 2014 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  9. Seven-star needle stimulation improves language and social interaction of children with autistic spectrum disorders.

    Science.gov (United States)

    Chan, Agnes S; Cheung, Mei-Chun; Sze, Sophia L; Leung, Winnie W

    2009-01-01

    This is a randomized controlled trial that aimed to evaluate the effect of the Seven-star Needle Stimulation treatment on children with Autistic Spectrum Disorders (ASD). Thirty-two children with ASD were assigned randomly into the treatment and control groups. Children in the treatment group underwent 30 sessions of stimulation over 6 weeks, while children in the control group were on a waiting list and did not receive treatment during this period of time. Intervention consisted of a treatment regime comprising of 30 sessions of Seven-star Needle Stimulation, delivered over 6 weeks. Each session lasted 5 to 10 min, children in the treatment group were stimulated at the front and back sides of their body and the head by using Seven-star Needles. The change in the children's behavior was evaluated using parents' report and neurophysiological changes were measured by quantitative EEG (qEEG). Results showed that the treatment group demonstrated significant improvement in language and social interaction, but not in stereotyped behavior or motor function, compared to the control group. qEEG spectral amplitudes in the treatment, but not in the control group, were also reduced significantly. The results suggested that Seven-star Needle Stimulation might be an effective intervention to improve language and social functioning of children with ASD.

  10. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  11. NUTRIENTS CONCENTRATION AND RETRANSLOCATION IN THE Pinus taeda L. NEEDLES

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2010-03-01

    Full Text Available Aiming at evaluating nutrients concentration and retranslocation in the Pinus taeda L. needles, this study was developed in two stands, in native grass area and in second rotation area, with same species and same age (7.5 years old in Cambará do Sul, RS. The needles were collected in plants in four orthogonal points (South, North, East and West, sampled new needles, mature needles and old needles. The material was dried in a stove, milled and chemically analyzed (macro and micronutrients. The concentrations of N, P, K, B, Cu and Zn had decreased, of Ca, Fe and Mn increased, and the Mg and S have remained constant with the age of the needles. The retranslocation rate (old-new needles was more than 50% for most nutrients, except for Mn and Fe, showed that cumulative effect and the Ca reference element.

  12. Investigation of environmental pollution with pine needles by NAA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Yong; Yoon, Yoon Yeol; Yang, Myung Kwon; Shim, Sang Kwon; Seo, Bum Kyoung [Korea Inst. of Geosience and Mineral Resources, Environmental Geology Division, Daejeon (Korea); Chung, Yong Sam [Korea Atomic Energy Research Inst., HANARO Center, Daejeon (Japan)

    2002-04-01

    NAA was studied to precision analysis of metallic elements in pine needle. The pine needle was investigated whether it can be feasible or not as a bio-monitor. Only one year old needle was taken from three different regions of urban, suburban and rural area in four seasons. The needle sample was divided with two aliquots, and then one was cleaned and the other was not. Loss and contamination of analytes were cautiously minimized when the needle was sample and transferred from mountain to laboratory and prepared for NAA. Some elements such as As, Br, Ce, W, Zn have shown different characteristics with regions and seasons as well as surface cleaning. It is found that about twenty elements in pine needle could be simply analyzed by NAA and the pine needle could be suitable as a bio-monitor for the monitoring of environmental pollution in Korea. (author)

  13. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  14. Needle thoracostomy in the treatment of a tension pneumothorax in trauma patients: what size needle?

    Science.gov (United States)

    Zengerink, Imme; Brink, Peter R; Laupland, Kevin B; Raber, Earl L; Zygun, Dave; Kortbeek, John B

    2008-01-01

    A tension pneumothorax requires immediate decompression using a needle thoracostomy. According to advanced trauma life support guidelines this procedure is performed in the second intercostal space (ICS) in the midclavicular line (MCL), using a 4.5-cm (2-inch) catheter (5-cm needle). Previous studies have shown a failure rate of up to 40% using this technique. Case reports have suggested that this high failure rate could be because of insufficient length of the needle. To analyze the average chest wall thickness (CWT) at the second ICS in the MCL in a trauma population and to evaluate the length of the needle used in needle thoracostomy for emergency decompression of tension pneumothoraces. Retrospective review of major trauma admissions (Injury Severity Score >12) at the Foothills Medical Centre in Calgary, Canada, who underwent a computed tomography chest scan admitted in the period from October 2001 until March 2004. Subgroup analysis on men and women, /=40 years of age was defined a priori. CWT was measured to the nearest 0.01 cm at the second ICS in the MCL. The mean CWT in the 604 male patients and 170 female patients studied averaged 3.50 cm at the left second ICS MCL and 3.51 cm on the right. The mean CWT was significantly higher for women than men (p 4.5 cm and 24.1% to 35.4% of the women studied. A catheter length of 4.5 cm may not penetrate the chest wall of a substantial amount (9.9%-35.4%) of the population, depending on age and gender. This study demonstrates the need for a variable needle length for relief of a tension pneumothorax in certain population groups to improve effectiveness of needle thoracostomy.

  15. Estimation of tissue stiffness, reflex activity, optimal muscle length and slack length in stroke patients using an electromyography driven antagonistic wrist model.

    Science.gov (United States)

    de Gooijer-van de Groep, Karin L; de Vlugt, Erwin; van der Krogt, Hanneke J; Helgadóttir, Áróra; Arendzen, J Hans; Meskers, Carel G M; de Groot, Jurriaan H

    2016-06-01

    About half of all chronic stroke patients experience loss of arm function coinciding with increased stiffness, reduced range of motion and a flexed wrist due to a change in neural and/or structural tissue properties. Quantitative assessment of these changes is of clinical importance, yet not trivial. The goal of this study was to quantify the neural and structural properties contributing to wrist joint stiffness and to compare these properties between healthy subjects and stroke patients. Stroke patients (n=32) and healthy volunteers (n=14) were measured using ramp-and-hold rotations applied to the wrist joint by a haptic manipulator. Neural (reflexive torque) and structural (connective tissue stiffness and slack lengths and (contractile) optimal muscle lengths) parameters were estimated using an electromyography driven antagonistic wrist model. Kruskal-Wallis analysis with multiple comparisons was used to compare results between healthy subjects, stroke patients with modified Ashworth score of zero and stroke patients with modified Ashworth score of one or more. Stroke patients with modified Ashworth score of one or more differed from healthy controls (Pslack length of connective tissue of the flexor muscles. Non-invasive quantitative analysis, including estimation of optimal muscle lengths, enables to identify neural and non-neural changes in chronic stroke patients. Monitoring these changes in time is important to understand the recovery process and to optimize treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. [Needling technique of Professor Li Yan-Fang].

    Science.gov (United States)

    Li, Li-Jun

    2014-01-01

    Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the

  17. A plasma needle generates nitric oxide

    International Nuclear Information System (INIS)

    Stoffels, E; Gonzalvo, Y Aranda; Whitmore, T D; Seymour, D L; Rees, J A

    2006-01-01

    Generation of nitric oxide (NO) by a plasma needle is studied by means of mass spectrometry. The plasma needle is an atmospheric glow generated by a radio-frequency excitation in a mixture of helium and air. This source is used for the treatment of living tissues, and nitric oxide may be one of the most important active agents in plasma therapy. Efficient NO generation is of particular importance in the treatment of cardiovascular diseases. Mass spectrometric measurements have been performed under various plasma conditions; gas composition in the plasma and conversion of feed gases (nitrogen and oxygen) into other species has been studied. Up to 30% of the N 2 and O 2 input is consumed in the discharge, and NO has been identified as the main conversion product

  18. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  19. Maxillofacial Changes in Melnick-Needles Syndrome

    Directory of Open Access Journals (Sweden)

    Leilane Larissa Albuquerque do Nascimento

    2016-01-01

    Full Text Available Background. Melnick-Needles Syndrome is rare congenital hereditary skeletal dysplasia caused by mutations in the FLNA gene, which codifies the protein filamin A. This condition leads to serious skeletal abnormalities, including the stomatognathic region. Case Presentation. This paper describes the case of a 13-year-old girl diagnosed with Melnick-Needles Syndrome presenting with different forms of skeletal dysplasia, such as cranial hyperostosis, short upper limbs, bowed long bones, metaphyseal thickening, genu valgum (knock-knee, shortened distal phalanges, narrow pelvis and shoulders, rib tapering and irregularities, elongation of the vertebrae, kyphoscoliosis, micrognathia, hypoplastic coronoid processes of the mandible, left stylohyoid ligament suggesting ossification, and dental development anomalies. Conclusion. Knowledge of this rare syndrome on the part of dentists is important due to the fact that this condition involves severe abnormalities of the stomatognathic system that cause an impact on the development of the entire face as well as functional and esthetic impairments.

  20. A retractable barb needle for drug darts

    Directory of Open Access Journals (Sweden)

    G.L. van Rooyen

    1973-07-01

    Full Text Available The mechanism and action of a new retractable barbneedle for drug darts are described. This dart needle is particularly successful in obviating unnecessary flight reactions andtrauma in darted animals, and facilitates the complete injection of the drug dose before the barb is retracted and the dart is dislogded from the animal. The whole process is completed within a few seconds and the expended dart can usually be retrieved in the immediate vicinity where the animal was darted.

  1. Pancreatic cancer seeding of percutaneous needle tract

    Directory of Open Access Journals (Sweden)

    Qiao Zhou, MD

    2017-03-01

    Full Text Available A 65-year old African-American female presents with biliary ductal dilatation due to an obstructive pancreatic head mass. Percutaneous transhepatic cholangiogram performed and biliary drainage catheter placement for decompression of the biliary system. The patient had a Whipple procedure performed several months later. On follow up CT imaging, there was interval development and enlargement of a subcutaneous lesion by the right oblique muscles. Biopsy of this lesion revealed pancreatic adenocarcinoma from percutaneous seeding of the transhepatic needle tract.

  2. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  3. [Design and application of silver needle-knife].

    Science.gov (United States)

    Sun, Guodong; Shi, Bin; Zhang, Benwu; Xu, Haidong

    2015-04-01

    A silver needle-knife which has the dual function of silver needle and needle-knife is designed. The main components of this silver needle-knife are approximately 50% silver and approximately 50% nichrome. The silver needle-knife is composed of five parts, including needle-knife tail, spiral handle; steering handle, needle-knife body and needle-knife edge. It converges the advantages of needle-knife and silver needle, which can cut loose of diseased tissue and peel adhesion of lesions, but also be heated with moxa cone and thermal therapeutic instrument, and connect with electroacupuncture apparatus. It has the function of warming channel and removing coldness, dispelling wind and eliminating dampness, resolving spasm and relieving pain, dredging the channel and so on. Due to the spiral handle and the steering handle, the operation is easier, which reduces the blindness of cutting and increase the safety. It is mainly used for soft tissue injury, rheumatism and rheumatoid arthritis, as well as degenerative diseases of spine and joint, and it has obvious efficacy on some internal medical diseases.

  4. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  5. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  6. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  7. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  8. Motor, affective and cognitive empathy in adolescence : Interrelations between facial electromyography and self-reported trait and state measures

    NARCIS (Netherlands)

    Van der Graaff, Jolien; Meeus, Wim; de Wied, Minet; van Boxtel, Anton; van Lier, Pol A C; Koot, Hans M.; Branje, Susan J. T.

    2016-01-01

    This study examined interrelations of trait and state empathy in an adolescent sample. Self-reported affective trait empathy and cognitive trait empathy were assessed during a home visit. During a test session at the university, motor empathy (facial electromyography), and self-reported affective

  9. Effect of a Short Time Concentric Versus Eccentric Training Program on Electromyography Activity and Peak Torque of Quadriceps

    DEFF Research Database (Denmark)

    Carvalho, Alberto; Caserotti, Paolo; Carvalho, C.

    2014-01-01

    The purpose of this study was to examine the effect of an 8-week concentric (CON) versus eccentric (ECC) isokinetic training program on the electromyography (EMG) signal amplitude of vastus medialis (VM), vastus lateralis (VL) and rectus femoris (RF). Also, the isometric (ISO) and dynamic maximum...

  10. Voluntary low-force contraction elicits prolonged low-frequency fatigue and changes in surface electromyography and mechanomyography

    DEFF Research Database (Denmark)

    Blangsted, Anne Katrine; Sjøgaard, Gisela; Madeleine, Pascal

    2005-01-01

    Controversies exist regarding objective documentation of fatigue development with low-force contractions. We hypothesized that non-exhaustive, low-force muscle contraction may induce prolonged low-frequency fatigue (LFF) that in the subsequent recovery period is detectable by electromyography (EMG...

  11. Combining Electromyography and Tactile Myography to Improve Hand and Wrist Activity Detection in Prostheses

    Directory of Open Access Journals (Sweden)

    Noémie Jaquier

    2017-10-01

    Full Text Available Despite recent advances in prosthetics and assistive robotics in general, robust simultaneous and proportional control of dexterous prosthetic devices remains an unsolved problem, mainly because of inadequate sensorization. In this paper, we study the application of regression to muscle activity, detected using a flexible tactile sensor recording muscle bulging in the forearm (tactile myography—TMG. The sensor is made of 320 highly sensitive cells organized in an array forming a bracelet. We propose the use of Gaussian process regression to improve the prediction of wrist, hand and single-finger activation, using TMG, surface electromyography (sEMG; the traditional approach in the field, and a combination of the two. We prove the effectiveness of the approach for different levels of activations in a real-time goal-reaching experiment using tactile data. Furthermore, we performed a batch comparison between the different forms of sensorization, using a Gaussian process with different kernel distances.

  12. Comparative study of a muscle stiffness sensor and electromyography and mechanomyography under fatigue conditions.

    Science.gov (United States)

    Han, Hyonyoung; Jo, Sungho; Kim, Jung

    2015-07-01

    This paper proposes the feasibility of a stiffness measurement for muscle contraction force estimation under muscle fatigue conditions. Bioelectric signals have been widely studied for the estimation of the contraction force for physical human-robot interactions, but the correlation between the biosignal and actual motion is decreased under fatigue conditions. Muscle stiffness could be a useful contraction force estimator under fatigue conditions because it measures the same physical quantity as the muscle contraction that generates the force. Electromyography (EMG), mechanomyography (MMG), and a piezoelectric resonance-based active muscle stiffness sensor were used to analyze the biceps brachii under isometric muscle fatigue conditions with reference force sensors at the end of the joint. Compared to EMG and MMG, the change in the stiffness signal was smaller (p fatigue condition changed fatigue conditions. This result indicates that the muscle stiffness signal is less sensitive to muscle fatigue than other biosignals. This investigation provides insights into methods of monitoring and compensating for muscle fatigue.

  13. [Analysis of the Muscle Fatigue Based on Band Spectrum Entropy of Multi-channel Surface Electromyography].

    Science.gov (United States)

    Liu, Jian; Zou, Renling; Zhang, Dongheng; Xu, Xiulin; Hu, Xiufang

    2016-06-01

    Exercise-induced muscle fatigue is a phenomenon that the maximum voluntary contraction force or power output of muscle is temporarily reduced due to muscular movement.If the fatigue is not treated properly,it will bring about a severe injury to the human body.With multi-channel collection of lower limb surface electromyography signals,this article analyzes the muscle fatigue by adoption of band spectrum entropy method which combined electromyographic signal spectral analysis and nonlinear dynamics.The experimental result indicated that with the increase of muscle fatigue,muscle signal spectrum began to move to low frequency,the energy concentrated,the system complexity came down,and the band spectrum entropy which reflected the complexity was also reduced.By monitoring the entropy,we can measure the degree of muscle fatigue,and provide an indicator to judge fatigue degree for the sports training and clinical rehabilitation training.

  14. Muscle conduction velocity, surface electromyography variables, and echo intensity during concentric and eccentric fatigue.

    Science.gov (United States)

    Gonzalez-Izal, Miriam; Lusa Cadore, Eduardo; Izquierdo, Mikel

    2014-03-01

    Concentric (CON) and eccentric (ECC) contractions may involve different mechanisms related to changes in sarcolemma status and the consequent alteration of action potential transmission along muscle fibers. Muscle conduction velocity (CV), surface electromyography signal (sEMG), muscle quality, and blood lactate concentrations were analyzed during CON and ECC actions. Compared with ECC, the CON protocol resulted in greater muscle force losses, blood lactate concentrations, and changes in sEMG parameters. Similar reductions in CV were detected in both protocols. Higher echo intensity values were observed 2 days after ECC due to greater muscle damage. The effects of the muscle damage produced by ECC exercise on the transmission of action potentials along muscle fibers (measured as the CV) may be comparable with the effects of hydrogen accumulation produced by CON exercise (related to greater lactate concentrations), which causes greater force loss and change in other sEMG variables during CON than during ECC actions.

  15. Estimation of muscle fatigue using surface electromyography and near-infrared spectroscopy.

    Science.gov (United States)

    Taelman, Joachim; Vanderhaegen, Joke; Robijns, Mieke; Naulaers, Gunnar; Spaepen, Arthur; Van Huffel, Sabine

    2011-01-01

    This study looks at various parameters, derived from surface electromyography (sEMG) and Near Infrared Spectroscopy (NIRS) and their relationship in muscle fatigue during a static elbow flexion until exhaustion as well as during a semidynamic exercise.We found a linear increasing trend for a corrected amplitude parameter and a linear decreasing slope for the frequency content of the sEMG signal. The tissue oxygenation index (TOI) extracted from NIRS recordings showed a four-phase response for all the subjects. A strong correlation between frequency content of the sEMG signal and TOI was established. We can conclude that both sEMG and NIRS give complementary information concerning muscle fatigue.

  16. Listening to music during electromyography does not influence the examinee's anxiety and pain levels.

    Science.gov (United States)

    Abraham, Alon; Drory, Vivian E

    2014-09-01

    Listening to music is a low-cost intervention that has demonstrated ability to reduce pain and anxiety levels in various medical procedures. Subjects undergoing electrophysiological examinations were randomized into a music-listening group and a control group. Visual analog scales were used to measure anxiety and pain levels during the procedure. Thirty subjects were randomized to each group. No statistically significant difference was found in anxiety or pain levels during the procedure between groups. However, most subjects in the music-listening group reported anxiety and pain reduction and would prefer to hear music in a future examination. Although listening to music during electrophysiological examinations did not reduce anxiety or pain significantly, most subjects felt a positive effect and would prefer to hear music; therefore, we suggest that music may be offered optionally in the electromyography laboratory setting. © 2014 Wiley Periodicals, Inc.

  17. Utilization and yield of nerve conduction studies and electromyography in older adults

    LENUS (Irish Health Repository)

    Mello, S

    2016-02-01

    Older adults are at increased risk of both central and peripheral neurological disorders. Impaired nerve and muscle deficits contribute to morbidity and reduced quality of life. Our aim was to define the utilization and yield of nerve conduction studies (NCS) and electromyography (EMG) in older adults. We reviewed NCS and EMG records for all patients older than age 65 in the year 2012. Of 1,530 NCS and EMGs performed, 352 (23%) were in patients older than 65 (mean age 73.7, 52% male). Two hundred and eighty-eight (83.7%) of NCS were abnormal as were 102 (71.8%) of EMGs. The likelihood of having an abnormal test result increased with increasing age. The most common diagnosis was peripheral neuropathy 231 (65.4%). The incidence of peripheral neuropathy is particularly high in this age group, and detection is vital to prevent morbidity and improve quality of life.

  18. Electromyography Activation Levels of the 3 Gluteus Medius Subdivisions During Manual Strength Testing

    DEFF Research Database (Denmark)

    Otten, Roald; Tol, Johannes L; Holmich, Per

    2015-01-01

    deficits and guide specific rehabilitation programs. However, the optimal positions for assessing the strength and activation of these subdivisions are unknown. OBJECTIVE: The first aim was to establish which strength-testing positions produce the highest surface electromyography (sEMG) activation levels...... of the individual GM subdivisions. The second aim was to evaluate differences in sEMG activation levels between the tested and contralateral (stabilizing) leg. METHOD: Twenty healthy physically active male subjects participated in this study. Muscle activity using sEMG was recorded for the GM subdivisions in 8......STUDY DESIGN: Cross-sectional. CONTEXT: Gluteus medius (GM) muscle dysfunction is associated with overuse injury. The GM is functionally composed of 3 separate subdivisions: anterior, middle, and posterior. Clinical assessment of the GM subdivisions is relevant to detect strength and activation...

  19. Experiences in the creation of an electromyography database to help hand amputated persons.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Heynen, Simone; Hager, Anne-Gabrielle Mittaz; Castellimi, Claudio; Caputo, Barbara; Müller, Henning

    2012-01-01

    Currently, trans-radial amputees can only perform a few simple movements with prosthetic hands. This is mainly due to low control capabilities and the long training time that is required to learn controlling them with surface electromyography (sEMG). This is in contrast with recent advances in mechatronics, thanks to which mechanical hands have multiple degrees of freedom and in some cases force control. To help improve the situation, we are building the NinaPro (Non-Invasive Adaptive Prosthetics) database, a database of about 50 hand and wrist movements recorded from several healthy and currently very few amputated persons that will help the community to test and improve sEMG-based natural control systems for prosthetic hands. In this paper we describe the experimental experiences and practical aspects related to the data acquisition.

  20. Age-Related Increase in Electromyography Burst Activity in Males and Females

    Directory of Open Access Journals (Sweden)

    Olga Theou

    2013-01-01

    Full Text Available The rapid advancement of electromyography (EMG technology facilitates measurement of muscle activity outside the laboratory during daily life. The purpose of this study was to determine whether bursts in EMG recorded over a typical 8-hour day differed between young and old males and females. Muscle activity was recorded from biceps brachii, triceps brachii, vastus lateralis, and biceps femoris of 16 young and 15 old adults using portable surface EMG. Old muscles were active 16–27% of the time compared to 5–9% in young muscles. The number of bursts was greater in old than young adults and in females compared to males. Burst percentage and mean amplitude were greater in the flexor muscles compared with the extensor muscles. The greater burst activity in old adults coupled with the unique activity patterns across muscles in males and females provides further understanding of how changes in neuromuscular activity effects age-related functional decline between the sexes.

  1. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  2. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  3. Risk of needle stick injuries in health care workers: bad habits (recapping needles) last long.

    Science.gov (United States)

    Rogowska-Szadkowska, Dorota; Stanisławowicz, Małgorzata; Chlabicz, Sławomir

    2010-01-01

    In order to assess the nurses' knowledge concerning the risk of hepatitis B and C viruses or human immunodeficiency virus infection while performing their professional duties, an anonymous questionnaire developed by the authors was distributed in 2008. Surprisingly 64% respondents occasionally recapping needles after injections, although they know the procedures which are obligatory at the ward. The first step in preventing percutaneous injuries should focus on efforts to eliminate the practice of recapping needles, though education and convenient placement of puncture-resistant containers for the disposal of used sharps.

  4. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  5. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  6. Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance

    Science.gov (United States)

    Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.

    2017-01-01

    Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026

  7. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  8. Evaluating the advances and use of hypodermic needles in dentistry.

    Science.gov (United States)

    Boynes, Sean G

    2014-10-01

    Different injection techniques and patient management methodologies have been proposed to decrease the fear patients may have concerning dental needles. Dental providers should have an understanding of the technological advances, changes in techniques, and patient perceptions associated with the hypodermic needle. This article provides an overview of the pain perception process associated with dental injections. It reviews the two main sensory nerve fibers associated with injection pain and discusses needle properties as well as complications and adverse occurrences.

  9. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  10. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  11. [Percutaneous needle aponeurotomy for Dupuytren's disease].

    Science.gov (United States)

    Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F

    2016-02-01

    Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.

  12. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  13. Effect and safety of deep needling and shallow needling for functional constipation: a multicenter, randomized controlled trial.

    Science.gov (United States)

    Wu, Jiani; Liu, Baoyan; Li, Ning; Sun, Jianhua; Wang, Lingling; Wang, Liping; Cai, Yuying; Ye, Yongming; Liu, Jun; Wang, Yang; Liu, Zhishun

    2014-12-01

    Aupuncture is widely used for functional constipation. Effect of acupuncture might be related to the depth of needling; however, the evidence is limited. This trial aimed to evaluate the effect and safety of deep needling and shallow needling for functional constipation, and to assess if the deep needling and shallow needling are superior to lactulose. We conducted a prospective, superiority-design, 5-center, 3-arm randomized controlled trial. A total of 475 patients with functional constipation were randomized to the deep needling group (237), shallow needling group (119), and lactulose-controlled group (119) in a ratio of 2:1:1. Sessions lasted 30 minutes each time and took place 5 times a week for 4 weeks in 2 acupuncture groups. Participants in the lactulose group took lactulose orally for 16 continuous weeks. The primary outcome was the change from baseline of mean weekly spontaneous bowel movements (SBMs) during week 1 to 4 (changes from the baselines of the weekly SBMs at week 8 and week 16 in follow-up period were also assessed simultaneously). Secondary outcomes were the weekly SBMs of each assessing week, the mean score change from the baseline of constipation-related symptoms over week 1 to 4, and the time to the first SBM. Emergency drug usage and adverse effects were monitored throughout the study.SBMs and constipation-related symptoms were all improved in the 3 groups compared with baseline at each time frame (Pdeep needling group, 2 (1.75) in the shallow needling group, and 2 (2) in the lactulose group (P>0.05, both compared with the lactulose group). The changes of mean weekly SBMs at week 8 and week 16 in the follow-up period were 2 (2), 2 (2.5) in the deep needling group, 2 (3), 1.5 (2.5) in the shallow needling group, and 1 (2), 1 (2) in the lactulose group (Pdeep or shallow needling group. Deep and shallow needling at Tianshu (ST25) can improve intestinal function remarkably and safely. Therapeutic effects of deep and shallow needling are not

  14. RF Photoelectric injectors using needle cathodes

    International Nuclear Information System (INIS)

    Lewellen, J.W.; Brau, C.A.

    2003-01-01

    Photocathode RF guns, in various configurations, are the injectors of choice for both current and future applications requiring high-brightness electron beams. Many of these applications, such as single-pass free-electron lasers, require beams with high brilliance but not necessarily high charge per bunch. Field-enhanced photoelectric emission has demonstrated electron-beam current density as high as 10 10 A/m 2 , with a quantum efficiency in the UV that approaches 10% at fields on the order of 10 10 V/m. Thus, the use of even a blunt needle holds promise for increasing cathode quantum efficiency without sacrificing robustness. We present an initial study on the use of needle cathodes in photoinjectors to enhance beam brightness while reducing beam charge. Benefits include lower drive-laser power requirements, easier multibunch operation, lower emittance, and lower beam degradation due to charge-dependent effects in the postinjector accelerator. These benefits result from a combination of a smaller cathode emission area, greatly enhanced RF field strength at the cathode, and the charge scaling of detrimental postinjector linac effects, e.g., transverse wakefields and CSR

  15. RF Photoelectric injectors using needle cathodes

    Science.gov (United States)

    Lewellen, J. W.; Brau, C. A.

    2003-07-01

    Photocathode RF guns, in various configurations, are the injectors of choice for both current and future applications requiring high-brightness electron beams. Many of these applications, such as single-pass free-electron lasers, require beams with high brilliance but not necessarily high charge per bunch. Field-enhanced photoelectric emission has demonstrated electron-beam current density as high as 10 10 A/m 2, with a quantum efficiency in the UV that approaches 10% at fields on the order of 10 10 V/m. Thus, the use of even a blunt needle holds promise for increasing cathode quantum efficiency without sacrificing robustness. We present an initial study on the use of needle cathodes in photoinjectors to enhance beam brightness while reducing beam charge. Benefits include lower drive-laser power requirements, easier multibunch operation, lower emittance, and lower beam degradation due to charge-dependent effects in the postinjector accelerator. These benefits result from a combination of a smaller cathode emission area, greatly enhanced RF field strength at the cathode, and the charge scaling of detrimental postinjector linac effects, e.g., transverse wakefields and CSR.

  16. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  17. Fine needle aspiration cytology of parapharyngeal tumors

    Directory of Open Access Journals (Sweden)

    Mondal Palash

    2009-01-01

    Full Text Available Background: Parapharyngeal tumors are rare and often pose diagnostic difficulties due to their location and plethora of presentations. Objectives: The study was undertaken to study the occurrence in the population and to evaluate the exact nature by fine needle aspiration cytology (FNAC. Materials and Methods: A total of five hundred and six cases of lateral neck lesions were studied over three and half years. Of these 56 suspected parapharyngeal masses were selected by clinical and radiological methods. Cytopathology evaluation was done by fine needle aspiration cytology with computed tomography and ultrasonography guidance wherever necessary. Histopathology confirmation was available in all the cases. Results: On FNAC diagnosis could be established in 54 cases while in two cases the material was insufficient to establish a diagnosis. The tumors encountered were, pleomorphic adenoma (33, schwannoma (3, neurofibroma (11, paraganglioma (5, angiofibroma (1 and adenoid cystic carcinoma (1. Four false positives and two false negative cases were encountered. Overall sensitivity was 96%, with specificity of 99% and accuracy being 98.8%. Conclusions: With proper clinical and radiological assessment, FNAC can be extremely useful in diagnosing most of these lesions except a few which need histopathological and even immunohistochemical confirmation.

  18. Investigations of needle-free jet injections.

    Science.gov (United States)

    Schramm-Baxter, J R; Mitragotri, S

    2004-01-01

    Jet injection is a needle-free drug delivery method in which a high-speed stream of fluid impacts the skin and delivers drugs. Although a number of jet injectors are commercially available, especially for insulin delivery, they have a low market share compared to needles possibly due to occasional pain associated with jet injection. Jets employed by the traditional jet injectors penetrate deep into the dermal and sub-dermal regions where the nerve endings are abundantly located. To eliminate the pain associated with jet injections, we propose to utilize microjets that penetrate only into the superficial region of the skin. However, the choice of appropriate jet parameters for this purpose is challenging owing to the multiplicity of factors that determine the penetration depth. Here, we describe the dependence of jet injections into human skin on the power of the jet. Dermal delivery of liquid jets was quantified using two measurements, penetration of a radiolabeled solute, mannitol, into skin and the shape of jet dispersion in the skin which was visualized using sulforhodamine B. The dependence of the amount of liquid delivered in the skin and the geometric measurements of jet dispersion on nozzle diameter and jet velocity was captured by a single parameter, jet power.

  19. Needle placement accuracy during stereotactic localization mammography

    International Nuclear Information System (INIS)

    Green, D.H.

    2009-01-01

    Aim: To derive a mathematical model to describe the relationship between lesion position in the breast and measurements derived from the stereoradiographs to enable more accurate sampling of a lesion during stereotactic mammographic needle placement. Materials and methods: The affect that registration errors have on the accuracy of needle placement when identifying the lesion on the stereoradiographs was investigated using the mathematical model. Results: The focus-to-film distance of the x-ray tube and the horizontal distance of the lesion from the centre of rotation have little effect on error. Registration errors for lesions lying at a greater perpendicular distance in the breast from the centre of rotation produce smaller localization errors when compared with lesions sited closer. Lesion registration errors during marking of the stereoradiographs are exacerbated by decreasing the angle of x-ray tube swing. Conclusions: When problems are encountered in making an accurate registration of the lesion on the stereoradiographs, consider the following error reducing strategies: (1) employ an approach that places the lesion the maximum distance away from the film cassette; (2) avoid reducing the angle of tube swing; and (3) consider sampling superficial and deep to, as well as at, the location indicated. The possibility of erroneous tissue sampling should be borne in mind when reviewing the pathology report.

  20. Virtual Sensor of Surface Electromyography in a New Extensive Fault-Tolerant Classification System.

    Science.gov (United States)

    de Moura, Karina de O A; Balbinot, Alexandre

    2018-05-01

    A few prosthetic control systems in the scientific literature obtain pattern recognition algorithms adapted to changes that occur in the myoelectric signal over time and, frequently, such systems are not natural and intuitive. These are some of the several challenges for myoelectric prostheses for everyday use. The concept of the virtual sensor, which has as its fundamental objective to estimate unavailable measures based on other available measures, is being used in other fields of research. The virtual sensor technique applied to surface electromyography can help to minimize these problems, typically related to the degradation of the myoelectric signal that usually leads to a decrease in the classification accuracy of the movements characterized by computational intelligent systems. This paper presents a virtual sensor in a new extensive fault-tolerant classification system to maintain the classification accuracy after the occurrence of the following contaminants: ECG interference, electrode displacement, movement artifacts, power line interference, and saturation. The Time-Varying Autoregressive Moving Average (TVARMA) and Time-Varying Kalman filter (TVK) models are compared to define the most robust model for the virtual sensor. Results of movement classification were presented comparing the usual classification techniques with the method of the degraded signal replacement and classifier retraining. The experimental results were evaluated for these five noise types in 16 surface electromyography (sEMG) channel degradation case studies. The proposed system without using classifier retraining techniques recovered of mean classification accuracy was of 4% to 38% for electrode displacement, movement artifacts, and saturation noise. The best mean classification considering all signal contaminants and channel combinations evaluated was the classification using the retraining method, replacing the degraded channel by the virtual sensor TVARMA model. This method

  1. Auto-Encoder based Deep Learning for Surface Electromyography Signal Processing

    Directory of Open Access Journals (Sweden)

    Marwa Farouk Ibrahim Ibrahim

    2018-01-01

    Full Text Available Feature extraction is taking a very vital and essential part of bio-signal processing. We need to choose one of two paths to identify and select features in any system. The most popular track is engineering handcrafted, which mainly depends on the user experience and the field of application. While the other path is feature learning, which depends on training the system on recognising and picking the best features that match the application. The main concept of feature learning is to create a model that is expected to be able to learn the best features without any human intervention instead of recourse the traditional methods for feature extraction or reduction and avoid dealing with feature extraction that depends on researcher experience. In this paper, Auto-Encoder will be utilised as a feature learning algorithm to practice the recommended model to excerpt the useful features from the surface electromyography signal. Deep learning method will be suggested by using Auto-Encoder to learn features. Wavelet Packet, Spectrogram, and Wavelet will be employed to represent the surface electromyography signal in our recommended model. Then, the newly represented bio-signal will be fed to stacked autoencoder (2 stages to learn features and finally, the behaviour of the proposed algorithm will be estimated by hiring different classifiers such as Extreme Learning Machine, Support Vector Machine, and SoftMax Layer. The Rectified Linear Unit (ReLU will be created as an activation function for extreme learning machine classifier besides existing functions such as sigmoid and radial basis function. ReLU will show a better classification ability than sigmoid and Radial basis function (RBF for wavelet, Wavelet scale 5 and wavelet packet signal representations implemented techniques. ReLU will illustrate better classification ability, as an activation function, than sigmoid and poorer than RBF for spectrogram signal representation. Both confidence interval and

  2. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  3. Essential Oil Composition of Pinus peuce Griseb. Needles and Twigs from Two National Parks of Kosovo.

    Science.gov (United States)

    Hajdari, Avni; Mustafa, Behxhet; Nebija, Dashnor; Selimi, Hyrmete; Veselaj, Zeqir; Breznica, Pranvera; Quave, Cassandra Leah; Novak, Johannes

    The principal aim of this study was to analyze the chemical composition and qualitative and quantitative variability of essential oils obtained from seven naturally grown populations of the Pinus peuce Grisebach, Pinaceae in Kosovo. Plant materials were collected from three populations in the Sharri National Park and from four other populations in the Bjeshkët e Nemuna National Park, in Kosovo. Essential oils were obtained by steam distillation and analyzed by GC-FID (Gas Chromatography-Flame Ionization Detection) and GC-MS (Gas Chromatography-Mass Spectrometry). The results showed that the yield of essential oils (v/w dry weight) varied depending on the origin of population and the plant organs and ranged from 0.7 to 3.3%. In total, 51 compounds were identified. The main compounds were α-pinene (needles: 21.6-34.9%; twigs: 11.0-24%), β-phellandrene (needles: 4.1-27.7; twigs: 29.0-49.8%), and β-pinene (needles: 10.0-16.1; twigs: 6.9-20.7%). HCA (Hierarchical Cluster Analysis) and PCA (Principal Component Analyses) were used to assess geographical variations in essential oil composition. Statistical analysis showed that the analyzed populations are grouped in three main clusters which seem to reflect microclimatic conditions on the chemical composition of the essential oils.

  4. Essential Oil Composition of Pinus peuce Griseb. Needles and Twigs from Two National Parks of Kosovo

    Directory of Open Access Journals (Sweden)

    Avni Hajdari

    2016-01-01

    Full Text Available The principal aim of this study was to analyze the chemical composition and qualitative and quantitative variability of essential oils obtained from seven naturally grown populations of the Pinus peuce Grisebach, Pinaceae in Kosovo. Plant materials were collected from three populations in the Sharri National Park and from four other populations in the Bjeshkët e Nemuna National Park, in Kosovo. Essential oils were obtained by steam distillation and analyzed by GC-FID (Gas Chromatography-Flame Ionization Detection and GC-MS (Gas Chromatography-Mass Spectrometry. The results showed that the yield of essential oils (v/w dry weight varied depending on the origin of population and the plant organs and ranged from 0.7 to 3.3%. In total, 51 compounds were identified. The main compounds were α-pinene (needles: 21.6–34.9%; twigs: 11.0–24%, β-phellandrene (needles: 4.1–27.7; twigs: 29.0–49.8%, and β-pinene (needles: 10.0–16.1; twigs: 6.9–20.7%. HCA (Hierarchical Cluster Analysis and PCA (Principal Component Analyses were used to assess geographical variations in essential oil composition. Statistical analysis showed that the analyzed populations are grouped in three main clusters which seem to reflect microclimatic conditions on the chemical composition of the essential oils.

  5. [Closed needle-biopsy in the diagnosis of neoplasms].

    Science.gov (United States)

    Sforza, M; Perelli Ercolini, M; Beani, G

    1979-04-01

    The AA. demonstrate with this communication the validity of the needle biopsie for the diagnosis of neoplasms. They had used it for the breast, thyroid, flg and some other superficial tumefactions. In the mass-screening for the feminine neoplasms the clinical examination and the needle biopsy are very good method for a careful diagnosis.

  6. Darning Needle Impacted in the Male Urethra | Singla | African ...

    African Journals Online (AJOL)

    Foreign bodies of varied nature have been introduced into the urethra to achieve sexual stimulation. We report the case of a long (9.5 cm) darning needle impacted in the urethra of a male patient following urethral masturbation. After a failed trial at endoscopic extraction the needle had to be removed via open surgery.

  7. Prevalence of Needle Stick Injuries among Healthcare Workers in ...

    African Journals Online (AJOL)

    Background: Needle stick injuries represent one of the most important occupational hazards to which health workers are exposed. These injuries result from accidental piercing of the skin and or mucous membranes by sharp objects. Needle stick injuries carry the risk of exposure to blood-borne pathogens, especially ...

  8. Effect of dietary mugwort ( Artemisia vulgaris L.) and pine needle ...

    African Journals Online (AJOL)

    The effects of dietary mugwort and pine needle powder supplementation on growth performance, serum cholesterol, and meat quality of broilers were evaluated in a 35 days feed trial. 200 one day old broilers were randomly allocated to five dietary treatments (0, 1 and 2% mugwort or 1 and 2% pine needle powder) with ...

  9. Improvements to the Processing and Characterization of Needled Composite Laminates

    Science.gov (United States)

    2014-01-01

    the automated processing equipment are shown and discussed. The modifications allow better spatial control at the penetration sites and the ability... automated processing equipment are shown and discussed. The modifications allow better spatial control at the penetration sites and the ability to...semi- automated processing equipment, commercial off-the-shelf (COTS) needles and COTS aramid mat designed for other applications. Needled material

  10. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  11. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  12. Needle-shaped and platelet growth of borax crystals

    International Nuclear Information System (INIS)

    Takoo, R.K.; Patel, B.R.; Joshi, M.S.

    1983-01-01

    Needle-shaped and platelet growth of borax crystals from solutions is reported. Results of microtopographical studies on both the varieties are discussed. It is suggested that a slow rate of evaporation favours needle growth and a faster rate is conducive to the growth of platelets. (author)

  13. Spinal anaesthesia in young patients: evaluation of needle gauge ...

    African Journals Online (AJOL)

    Background:The well-known complication of spinal anaesthesia, postdural puncture headache (PDPH), is especially troublesome in young patients. The needle gauge and configuration of needle tip appear to be the important factors in reducing the incidence of PDPH; however it may increase the incidence of technical ...

  14. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  15. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  16. Laser-Controlled Growth of Needle-Shaped Organic Nanoaggregates

    DEFF Research Database (Denmark)

    Balzer, Frank; Rubahn, Horst-Günter

    2002-01-01

    Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometer....... While the orientation of the individual molecules in the needles is defined by the direction of surface dipoles, the localization on the surface, the length distribution as well as mutual distances can be adjusted via size and position of the laser focus spot.......Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometers...

  17. NEEDLE KNIFE SPHINCTEROTOMY - THE CHRIS HANI BARAGWANATH ACADEMIC HOSPITAL EXPERIENCE.

    Science.gov (United States)

    Thomson, J T; Smith, M D; Omoshoro-Jones, J A O; Devar, J D; Khan, Z K; Jugmohan, B J

    2017-06-01

    Deep biliary cannulation is essential in performing a therapeutic ERCP. Cannulation can be enhanced through the utilization of a pre-cut by means of a needle knife sphincterotomy. Retrospective analysis of the Chris Hani Baragwanath Academic Hospital's ERCP database was performed. All ERCPs performed with the aid of a needle knife were identified and analysed for successful and unsuccessful deep biliary cannulation. 2830 ERCPs were performed during the study period. 369 (13%) required needle knife sphincterotomies and successful deep biliary cannulation was achieved in 229 (62%) of these patients. Repeat ERCPs were performed on 125 (34%) patients. 61 (49%) of the repeat ERCPs were performed because of previously failed cannulation. 34 (56%) of these repeat ERCPs resulted in successful deep biliary cannulation at re-attempt. 99% of successful cannulations at repeat ERCP had had a needle knife sphincterotomy at the first ERCP. Needle knife sphincterotomy improves deep biliary cannulation at initial ERCP and subsequent ERCPs with low incidences of complications.

  18. CUDA accelerated simulation of needle insertions in deformable tissue

    International Nuclear Information System (INIS)

    Patriciu, Alexandru

    2012-01-01

    This paper presents a stiff needle-deformable tissue interaction model. The model uses a mesh-less discretization of continuum; avoiding thus the expensive remeshing required by the finite element models. The proposed model can accommodate both linear and nonlinear material characteristics. The needle-deformable tissue interaction is modeled through fundamental boundaries. The forces applied by the needle on the tissue are divided in tangent forces and constraint forces. The constraint forces are adaptively computed such that the material is properly constrained by the needle. The implementation is accelerated using NVidia CUDA. We present detailed analysis of the execution timing in both serial and parallel case. The proposed needle insertion model was integrated in a custom software that loads DICOM images, generate the deformable model, and can simulate different insertion strategies.

  19. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  20. Correlation analysis between surface electromyography and continuous-wave near-infrared spectroscopy parameters during isometric exercise to volitional fatigue

    OpenAIRE

    ŞAYLİ, Ömer; AKIN, Ata; ÇOTUK, Hasan Birol

    2014-01-01

    In this study, the process of muscular fatigue was examined using surface electromyography (sEMG) and continuous-wave near-infrared spectroscopy (cw-NIRS) simultaneously during an isometric hand grip exercise at 50% and 75% of the maximal voluntary contraction (MVC), sustained until volitional fatigue. The mean frequency of the sEMG decreased during the whole exercise, whereas the root mean square had a tendency to increase. Oxyhemoglobin/deoxyhemoglobin concentration changes computed ...

  1. A comparative study of various electrodes in electromyography of the striated urethral and anal sphincter in children

    DEFF Research Database (Denmark)

    Nielsen, K K; Kristensen, E S; Qvist, N

    1985-01-01

    The series comprised 41 children aged 6 to 14 years consecutively referred with recurrent urinary tract infection and/or enuresis. Carbon dioxide cystometry was carried out in the supine and the erect position and combined with simultaneous electromyography (EMG). The external urethral sphincter ....... Correlation between them was good, as was reproducibility. Perianal surface ECG electrodes are recommended for the evaluation of functional disturbances of the external sphincter. They are painless, easy to use, and are well tolerated by the patient....

  2. Electromyography data for non-invasive naturally-controlled robotic hand prostheses.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Castellini, Claudio; Caputo, Barbara; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Müller, Henning

    2014-01-01

    Recent advances in rehabilitation robotics suggest that it may be possible for hand-amputated subjects to recover at least a significant part of the lost hand functionality. The control of robotic prosthetic hands using non-invasive techniques is still a challenge in real life: myoelectric prostheses give limited control capabilities, the control is often unnatural and must be learned through long training times. Meanwhile, scientific literature results are promising but they are still far from fulfilling real-life needs. This work aims to close this gap by allowing worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark scientific database. The database is targeted at studying the relationship between surface electromyography, hand kinematics and hand forces, with the final goal of developing non-invasive, naturally controlled, robotic hand prostheses. The validation section verifies that the data are similar to data acquired in real-life conditions, and that recognition of different hand tasks by applying state-of-the-art signal features and machine-learning algorithms is possible.

  3. The Advantages of Normalizing Electromyography to Ballistic Rather than Isometric or Isokinetic Tasks.

    Science.gov (United States)

    Suydam, Stephen M; Manal, Kurt; Buchanan, Thomas S

    2017-07-01

    Isometric tasks have been a standard for electromyography (EMG) normalization stemming from anatomic and physiologic stability observed during contraction. Ballistic dynamic tasks have the benefit of eliciting maximum EMG signals for normalization, despite having the potential for greater signal variability. It is the purpose of this study to compare maximum voluntary isometric contraction (MVIC) to nonisometric tasks with increasing degrees of extrinsic variability, ie, joint range of motion, velocity, rate of contraction, etc., to determine if the ballistic tasks, which elicit larger peak EMG signals, are more reliable than the constrained MVIC. Fifteen subjects performed MVIC, isokinetic, maximum countermovement jump, and sprint tasks while EMG was collected from 9 muscles in the quadriceps, hamstrings, and lower leg. The results revealed the unconstrained ballistic tasks were more reliable compared to the constrained MVIC and isokinetic tasks for all triceps surae muscles. The EMG from sprinting was more reliable than the constrained cases for both the hamstrings and vasti. The most reliable EMG signals occurred when the body was permitted its natural, unconstrained motion. These results suggest that EMG is best normalized using ballistic tasks to provide the greatest within-subject reliability, which beneficially yield maximum EMG values.

  4. Wrist Rehabilitation Assisted by an Electromyography-Driven Neuromuscular Electrical Stimulation Robot After Stroke.

    Science.gov (United States)

    Hu, Xiao-Ling; Tong, Raymond Kai-yu; Ho, Newmen S K; Xue, Jing-jing; Rong, Wei; Li, Leonard S W

    2015-09-01

    Augmented physical training with assistance from robot and neuromuscular electrical stimulation (NMES) may introduce intensive motor improvement in chronic stroke. To compare the rehabilitation effectiveness achieved by NMES robot-assisted wrist training and that by robot-assisted training. This study was a single-blinded randomized controlled trial with a 3-month follow-up. Twenty-six hemiplegic subjects with chronic stroke were randomly assigned to receive 20-session wrist training with an electromyography (EMG)-driven NMES robot (NMES robot group, n = 11) and with an EMG-driven robot (robot group, n = 15), completed within 7 consecutive weeks. Clinical scores, Fugl-Meyer Assessment (FMA), Modified Ashworth Score (MAS), and Action Research Arm Test (ARAT) were used to evaluate the training effects before and after the training, as well as 3 months later. An EMG parameter, muscle co-contraction index, was also applied to investigate the session-by-session variation in muscular coordination patterns during the training. The improvement in FMA (shoulder/elbow, wrist/hand) obtained in the NMES robot group was more significant than the robot group (P rehabilitation progress. © The Author(s) 2014.

  5. Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2012-01-01

    Full Text Available The human hand has multiple degrees of freedom (DOF for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  6. Hand motion classification using a multi-channel surface electromyography sensor.

    Science.gov (United States)

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  7. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    Science.gov (United States)

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Implementation of a Surface Electromyography-Based Upper Extremity Exoskeleton Controller Using Learning from Demonstration

    Science.gov (United States)

    Arenas, Ana M.; Sun, Tingxiao

    2018-01-01

    Upper-extremity exoskeletons have demonstrated potential as augmentative, assistive, and rehabilitative devices. Typical control of upper-extremity exoskeletons have relied on switches, force/torque sensors, and surface electromyography (sEMG), but these systems are usually reactionary, and/or rely on entirely hand-tuned parameters. sEMG-based systems may be able to provide anticipatory control, since they interface directly with muscle signals, but typically require expert placement of sensors on muscle bodies. We present an implementation of an adaptive sEMG-based exoskeleton controller that learns a mapping between muscle activation and the desired system state during interaction with a user, generating a personalized sEMG feature classifier to allow for anticipatory control. This system is robust to novice placement of sEMG sensors, as well as subdermal muscle shifts. We validate this method with 18 subjects using a thumb exoskeleton to complete a book-placement task. This learning-from-demonstration system for exoskeleton control allows for very short training times, as well as the potential for improvement in intent recognition over time, and adaptation to physiological changes in the user, such as those due to fatigue. PMID:29401754

  9. The use of surface electromyography as a tool in differentiating temporomandibular disorders from neck disorders.

    Science.gov (United States)

    Ferrario, Virgilio F; Tartaglia, Gianluca M; Luraghi, Francesca E; Sforza, Chiarella

    2007-11-01

    The aim of this study was to assess the electromyographic characteristics of the masticatory muscles (masseter and temporalis) of patients with either "temporomandibular joint disorder" or "neck pain". Surface electromyography of the right and left masseter and temporalis muscles was performed during maximum teeth clenching in 38 patients aged 21-67 years who had either (a) temporomandibular joint disorder (24 patients); (b) "neck pain" (13 patients). Ninety-five control, healthy subjects were also examined. During clenching, standardized total muscle activities (electromyographic potentials over time) were significantly different in the three groups: 75 microV/microVs% in the temporomandibular joint disorder patients, 124 microV/microVs% in the neck pain patients, and 95 microV/microVs% in the control subjects (analysis of variance, Ptemporomandibular joint disorder patients also had significantly (Pneck pain patients (87%) or control subjects (92%). A linear discriminant function analysis allowed a significant separation between the two patient groups, with a single patient error of 18.2%. Surface electromyographic analysis during clenching allowed to differentiate between patients with a temporomandibular joint disorder and patients with a neck pain problem.

  10. Reliability of surface electromyography timing parameters in gait in cervical spondylotic myelopathy.

    LENUS (Irish Health Repository)

    Malone, Ailish

    2012-02-01

    The aims of this study were to validate a computerised method to detect muscle activity from surface electromyography (SEMG) signals in gait in patients with cervical spondylotic myelopathy (CSM), and to evaluate the test-retest reliability of the activation times designated by this method. SEMG signals were recorded from rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA), and medial gastrocnemius (MG), during gait in 12 participants with CSM on two separate test days. Four computerised activity detection methods, based on the Teager-Kaiser Energy Operator (TKEO), were applied to a subset of signals and compared to visual interpretation of muscle activation. The most accurate method was then applied to all signals for evaluation of test-retest reliability. A detection method based on a combined slope and amplitude threshold showed the highest agreement (87.5%) with visual interpretation. With respect to reliability, the standard error of measurement (SEM) of the timing of RF, TA and MG between test days was 5.5% stride duration or less, while the SEM of BF was 9.4%. The timing parameters of RF, TA and MG designated by this method were considered sufficiently reliable for use in clinical practice, however the reliability of BF was questionable.

  11. Detection of compensatory balance responses using wearable electromyography sensors for fall-risk assessment.

    Science.gov (United States)

    Nouredanesh, Mina; Kukreja, Sunil L; Tung, James

    2016-08-01

    Loss of balance is prevalent in older adults and populations with gait and balance impairments. The present paper aims to develop a method to automatically distinguish compensatory balance responses (CBRs) from normal gait, based on activity patterns of muscles involved in maintaining balance. In this study, subjects were perturbed by lateral pushes while walking and surface electromyography (sEMG) signals were recorded from four muscles in their right leg. To extract sEMG time domain features, several filtering characteristics and segmentation approaches are examined. The performance of three classification methods, i.e., k-nearest neighbor, support vector machines, and random forests, were investigated for accurate detection of CBRs. Our results show that features extracted in the 50-200Hz band, segmented using peak sEMG amplitudes, and a random forest classifier detected CBRs with an accuracy of 92.35%. Moreover, our results support the important role of biceps femoris and rectus femoris muscles in stabilization and consequently discerning CBRs. This study contributes towards the development of wearable sensor systems to accurately and reliably monitor gait and balance control behavior in at-home settings (unsupervised conditions), over long periods of time, towards personalized fall risk assessment tools.

  12. Importance of electromyography and the electrophysiological severity scale in forensic reports.

    Science.gov (United States)

    Bilgin, Nursel Gamsiz; Ozge, Aynur; Mert, Ertan; Yalçinkaya, Deniz E; Kar, Hakan

    2007-05-01

    Forensic reports on traumatic peripheral nerve injuries include dysfunction degrees of extremities, which are arranged according to the Turkish Penalty Code. The aim of this study is to discuss the role and importance of electromyography while preparing forensic reports in the cases of traumatic peripheral nerve injuries and the usefulness of scoring systems. A modified global scale, recommended by Mondelli et al., was used to assess the electrophysiological impairment of each peripheral nerve. Forensic reports of 106 patients, reported between 2002 and 2004, were evaluated. Thirty-four percent of the cases were reported as "total loss of function," 41.5% were reported as "functional disability," and there were no dysfunctions in the other cases in forensic reports that were prepared based on Council of Social Insurance Regulations of Health Processes and Guide prepared by the Council of Forensic Medicine and profession associations of forensic medicine. When we rearranged these forensic reports based on the electrophysiological severity scale (ESS), it was clearly found that all of the score 2 cases and 86.7% of the score 3 cases corresponded to "functional disability" and 91.4% of the score 4 cases correspond to "total loss of function." We found a significant correlation between the ESS and functional evaluation in peripheral nerve injury cases. Evaluation of functional disabilities in peripheral nerve injuries with the ESS represents a standardized and objective method used for forensic reports.

  13. Effect of electrocardiographic contamination on surface electromyography assessment of back muscles.

    Science.gov (United States)

    Hu, Yong; Mak, Joseph N F; Luk, Keith D K

    2009-02-01

    The purpose of this study was to demonstrate the relative effect of electrocardiography (ECG) on back muscle surface electromyography (SEMG) parameters and their corresponding sensitivity in low back pain (LBP) assessment. Back muscle SEMG activities were recorded from 17 healthy subjects and 18 chronic LBP patients under static postures (straight sitting and upright standing), and dynamic action (flexion-extension). ECG cancellation based on independent component analysis (ICA) method was performed. Root mean square (RMS) and median frequency (MF) of raw and denoised SEMG data were computed respectively. Multiple comparisons were then performed. A consistent trend of change (increased MF and decreased RMS) followed ECG removal was noticed. In particular, in SEMG measurements under static postures, a significant decrease in RMS (pcorruption by ECG artifacts on SEMG measurements was found to be more serious and prominent in static postures than that in dynamic action. After ECG removal, significant improvements in the ability of SEMG to discriminate LBP patients from healthy subjects were seen in RMS amplitude recorded while standing (peffect of ECG contamination on back muscles SEMG parameters and LBP assessment.

  14. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  15. Implementation of a Surface Electromyography-Based Upper Extremity Exoskeleton Controller Using Learning from Demonstration

    Directory of Open Access Journals (Sweden)

    Ho Chit Siu

    2018-02-01

    Full Text Available Upper-extremity exoskeletons have demonstrated potential as augmentative, assistive, and rehabilitative devices. Typical control of upper-extremity exoskeletons have relied on switches, force/torque sensors, and surface electromyography (sEMG, but these systems are usually reactionary, and/or rely on entirely hand-tuned parameters. sEMG-based systems may be able to provide anticipatory control, since they interface directly with muscle signals, but typically require expert placement of sensors on muscle bodies. We present an implementation of an adaptive sEMG-based exoskeleton controller that learns a mapping between muscle activation and the desired system state during interaction with a user, generating a personalized sEMG feature classifier to allow for anticipatory control. This system is robust to novice placement of sEMG sensors, as well as subdermal muscle shifts. We validate this method with 18 subjects using a thumb exoskeleton to complete a book-placement task. This learning-from-demonstration system for exoskeleton control allows for very short training times, as well as the potential for improvement in intent recognition over time, and adaptation to physiological changes in the user, such as those due to fatigue.

  16. Coherence explored between emotion components: evidence from event-related potentials and facial electromyography.

    Science.gov (United States)

    Gentsch, Kornelia; Grandjean, Didier; Scherer, Klaus R

    2014-04-01

    Componential theories assume that emotion episodes consist of emergent and dynamic response changes to relevant events in different components, such as appraisal, physiology, motivation, expression, and subjective feeling. In particular, Scherer's Component Process Model hypothesizes that subjective feeling emerges when the synchronization (or coherence) of appraisal-driven changes between emotion components has reached a critical threshold. We examined the prerequisite of this synchronization hypothesis for appraisal-driven response changes in facial expression. The appraisal process was manipulated by using feedback stimuli, presented in a gambling task. Participants' responses to the feedback were investigated in concurrently recorded brain activity related to appraisal (event-related potentials, ERP) and facial muscle activity (electromyography, EMG). Using principal component analysis, the prediction of appraisal-driven response changes in facial EMG was examined. Results support this prediction: early cognitive processes (related to the feedback-related negativity) seem to primarily affect the upper face, whereas processes that modulate P300 amplitudes tend to predominantly drive cheek region responses. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Evoked electromyography to rocuronium in orbicularis oris and gastrocnemius in facial nerve injury in rabbits.

    Science.gov (United States)

    Xing, Yian; Chen, Lianhua; Li, Shitong

    2013-11-01

    Muscles innervated by the facial nerve show different sensitivities to muscle relaxants than muscles innervated by somatic nerves, especially in the presence of facial nerve injury. We compared the evoked electromyography (EEMG) response of orbicularis oris and gastrocnemius in with and without a non-depolarizing muscle relaxant in a rabbit model of graded facial nerve injury. Differences in EEMG response and inhibition by rocuronium were measured in the orbicularis oris and gastrocnemius muscles 7 to 42 d after different levels of facial nerve crush injuries in adult rabbits. Baseline EEMG of orbicularis oris was significantly smaller than those of the gastrocnemius. Gastrocnemius was more sensitive to rocuronium than the facial muscles (P rocuronium was negatively correlated with the magnitude of facial nerve injury but the sensitivity to rocuronium was not. No significant difference was found in the onset time and the recovery time of rocuronium among gastrocnemius and normal or damaged facial muscles. Muscles innervated by somatic nerves are more sensitive to rocuronium than those innervated by the facial nerve, but while facial nerve injury reduced EEMG responses, the sensitivity to rocuronium is not altered. Partial neuromuscular blockade may be a suitable technique for conducting anesthesia and surgery safely when EEMG monitoring is needed to preserve and protect the facial nerve. Additional caution should be used if there is a risk of preexisting facial nerve injury. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Shoulder muscle fatigue during repetitive tasks as measured by electromyography and near-infrared spectroscopy.

    Science.gov (United States)

    Ferguson, Sue A; Allread, W Gary; Le, Peter; Rose, Joseph; Marras, William S

    2013-12-01

    The objective of this study was to quantify shoulder muscle fatigue during repetitive exertions similar to motions found in automobile assembly tasks. Shoulder musculoskeletal disorders (MSDs) are a common and costly problem in automotive manufacturing. Ten subjects participated in the study. There were three independent variables: shoulder angle, frequency, and force. There were two types of dependent measures: percentage change in near-infrared spectroscopy (NIRS) measures and change in electromyography (EMG) median frequency. The anterior deltoid and trapezius muscles were measured for both NIRS and EMG. Also, EMG was collected on the middle deltoid and biceps muscles. The results showed that oxygenated hemoglobin decreased significantly due to the main effects (shoulder angle, frequency, and force). The percentage change in oxygenated hemoglobin had a significant interaction attributable to force and repetition for the anterior deltoid muscle, indicating that as repetition increased, the magnitude of the differences between the forces increased. The interaction of repetition and shoulder angle was also significant for the percentage change in oxygenated hemoglobin. The median frequency decreased significantly for the main effects; however, no interactions were statistically significant. There was significant shoulder muscle fatigue as a function of shoulder angle, task frequency, and force level. Furthermore, percentage change in oxygenated hemoglobin had two statistically significant interactions, enhancing our understanding of these risk factors. Ergonomists should examine interactions of force and repetition as well as shoulder angle and repetition when evaluating the risk of shoulder MSDs.

  19. Test-retest reliability of trunk motor variability measured by large-array surface electromyography.

    Science.gov (United States)

    Abboud, Jacques; Nougarou, François; Loranger, Michel; Descarreaux, Martin

    2015-01-01

    The objective of this study was to evaluate the test-retest reliability of the trunk muscle activity distribution in asymptomatic participants during muscle fatigue using large-array surface electromyography (EMG). Trunk muscle activity distribution was evaluated twice, with 3 to 4 days between them, in 27 asymptomatic volunteers using large-array surface EMG. Motor variability, assessed with 2 different variables (the centroid coordinates of the root mean square map and the dispersion variable), was evaluated during a low back muscle fatigue task. Test-retest reliability of muscle activity distribution was obtained using Pearson correlation coefficients. A shift in the distribution of EMG amplitude toward the lateral-caudal region of the lumbar erector spinae induced by muscle fatigue was observed. Moderate to very strong correlations were found between both sessions in the last 3 phases of the fatigue task for both motor variability variables, whereas weak to moderate correlations were found in the first phases of the fatigue task only for the dispersion variable. These findings show that, in asymptomatic participants, patterns of EMG activity are less reliable in initial stages of muscle fatigue, whereas later stages are characterized by highly reliable patterns of EMG activity. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  20. Exercise muscle fatigue detection system implementation via wireless surface electromyography and empirical mode decomposition.

    Science.gov (United States)

    Chang, Kang-Ming; Liu, Shing-Hong; Wang, Jia-Jung; Cheng, Da-Chuan

    2013-01-01

    Surface electromyography (sEMG) is an important measurement for monitoring exercise and fitness. A wireless Bluetooth transmission sEMG measurement system with a sampling frequency of 2 KHz is developed. Traditional muscle fatigue is detected from the median frequency of the sEMG power spectrum. The regression slope of the linear regression of median frequency is an important muscle fatigue index. As fatigue increases, the power spectrum of the sEMG shifts toward lower frequencies. The goal of this study is to evaluate the sensitivity of empirical mode decomposition (EMD) quantifying the electrical manifestations of the local muscle fatigue during exercising in health people. We also compared this method with the raw data and discrete wavelet transform (DWT). Five male and five female volunteers participated. Each subject was asked to run on a multifunctional pedaled elliptical trainer for about 30 minutes, twice a week, and there were a total of six recording times for each subject with a wireless EMG recording system. The results show that sensitivity of the highest frequency component of EMD is better than the highest frequency component of DWT, and raw data.

  1. Surface electromyography based muscle fatigue analysis for stroke patients at different Brunnstrom stages.

    Science.gov (United States)

    Yinjun Tu; Zhe Zhang; Xudong Gu; Qiang Fang

    2016-08-01

    Muscle fatigue analysis has been an important topic in sport and rehabilitation medicine due to its role in muscle performance evaluation and pathology investigation. This paper proposes a surface electromyography (sEMG) based muscle fatigue analysis approach which was specifically designed for stroke rehabilitation applications. 14 stroke patients from 5 different Brunnstrom recovery stage groups were involved in the experiment and features including median frequency and mean power frequency were extracted from the collected sEMG samples for investigation. After signal decomposition, the decline of motor unit firing rate of patients from different groups had also been studied. Statistically significant presence of fatigue had been observed in deltoideus medius and extensor digitorum communis of patients at early recovery stages (P0.01). It had also been discovered that the motor unit firing frequency declines with a range positively correlated to the recovery stage during repetitive movements. Based on the experiment result, it can be verified that as the recovery stage increases, the central nervous system's control ability strengthens and the patient motion becomes more stable and resistive to fatigue.

  2. Improved Prediction of Preterm Delivery Using Empirical Mode Decomposition Analysis of Uterine Electromyography Signals.

    Directory of Open Access Journals (Sweden)

    Peng Ren

    Full Text Available Preterm delivery increases the risk of infant mortality and morbidity, and therefore developing reliable methods for predicting its likelihood are of great importance. Previous work using uterine electromyography (EMG recordings has shown that they may provide a promising and objective way for predicting risk of preterm delivery. However, to date attempts at utilizing computational approaches to achieve sufficient predictive confidence, in terms of area under the curve (AUC values, have not achieved the high discrimination accuracy that a clinical application requires. In our study, we propose a new analytical approach for assessing the risk of preterm delivery using EMG recordings which firstly employs Empirical Mode Decomposition (EMD to obtain their Intrinsic Mode Functions (IMF. Next, the entropy values of both instantaneous amplitude and instantaneous frequency of the first ten IMF components are computed in order to derive ratios of these two distinct components as features. Discrimination accuracy of this approach compared to those proposed previously was then calculated using six differently representative classifiers. Finally, three different electrode positions were analyzed for their prediction accuracy of preterm delivery in order to establish which uterine EMG recording location was optimal signal data. Overall, our results show a clear improvement in prediction accuracy of preterm delivery risk compared with previous approaches, achieving an impressive maximum AUC value of 0.986 when using signals from an electrode positioned below the navel. In sum, this provides a promising new method for analyzing uterine EMG signals to permit accurate clinical assessment of preterm delivery risk.

  3. Changes in shoulder muscle activity pattern on surface electromyography after breast cancer surgery.

    Science.gov (United States)

    Yang, Eun Joo; Kwon, YoungOk

    2018-02-01

    Alterations in muscle activation and restricted shoulder mobility, which are common in breast cancer patients, have been found to affect upper limb function. The purpose of this study was to determine muscle activity patterns, and to compare the prevalence of abnormal patterns among the type of breast surgery. In total, 274 breast cancer patients were recruited after surgery. Type of breast surgery was divided into mastectomy without reconstruction (Mastectomy), reconstruction with tissue expander/implant (TEI), latissimus dorsi (LD) flap, or transverse rectus abdominis flap (TRAM). Activities of shoulder muscles were measured using surface electromyography. Experimental analysis was conducted using a Gaussian filter smoothing method with regression. Patients demonstrated different patterns of muscle activation, such as normal, lower muscle electrical activity, and tightness. After adjusting for BMI and breast surgery, the odds of lower muscle electrical activity and tightness in the TRAM are 40.2% and 38.4% less than in the Mastectomy only group. The prevalence of abnormal patterns was significantly greater in the ALND than SLNB in all except TRAM. Alterations in muscle activity patterns differed by breast surgery and reconstruction type. For breast cancer patients with ALND, TRAM may be the best choice for maintaining upper limb function. © 2017 Wiley Periodicals, Inc.

  4. Normalised Mutual Information of High-Density Surface Electromyography during Muscle Fatigue

    Directory of Open Access Journals (Sweden)

    Adrian Bingham

    2017-12-01

    Full Text Available This study has developed a technique for identifying the presence of muscle fatigue based on the spatial changes of the normalised mutual information (NMI between multiple high density surface electromyography (HD-sEMG channels. Muscle fatigue in the tibialis anterior (TA during isometric contractions at 40% and 80% maximum voluntary contraction levels was investigated in ten healthy participants (Age range: 21 to 35 years; Mean age = 26 years; Male = 4, Female = 6. HD-sEMG was used to record 64 channels of sEMG using a 16 by 4 electrode array placed over the TA. The NMI of each electrode with every other electrode was calculated to form an NMI distribution for each electrode. The total NMI for each electrode (the summation of the electrode’s NMI distribution highlighted regions of high dependence in the electrode array and was observed to increase as the muscle fatigued. To summarise this increase, a function, M(k, was defined and was found to be significantly affected by fatigue and not by contraction force. The technique discussed in this study has overcome issues regarding electrode placement and was used to investigate how the dependences between sEMG signals within the same muscle change spatially during fatigue.

  5. Multiscale musculoskeletal modelling, data–model fusion and electromyography-informed modelling

    Science.gov (United States)

    Zhang, J.; Heidlauf, T.; Sartori, M.; Besier, T.; Röhrle, O.; Lloyd, D.

    2016-01-01

    This paper proposes methods and technologies that advance the state of the art for modelling the musculoskeletal system across the spatial and temporal scales; and storing these using efficient ontologies and tools. We present population-based modelling as an efficient method to rapidly generate individual morphology from only a few measurements and to learn from the ever-increasing supply of imaging data available. We present multiscale methods for continuum muscle and bone models; and efficient mechanostatistical methods, both continuum and particle-based, to bridge the scales. Finally, we examine both the importance that muscles play in bone remodelling stimuli and the latest muscle force prediction methods that use electromyography-assisted modelling techniques to compute musculoskeletal forces that best reflect the underlying neuromuscular activity. Our proposal is that, in order to have a clinically relevant virtual physiological human, (i) bone and muscle mechanics must be considered together; (ii) models should be trained on population data to permit rapid generation and use underlying principal modes that describe both muscle patterns and morphology; and (iii) these tools need to be available in an open-source repository so that the scientific community may use, personalize and contribute to the database of models. PMID:27051510

  6. Evaluation of muscular activity duration in shoulders with rotator cuff tears using inertial sensors and electromyography

    International Nuclear Information System (INIS)

    Duc, Cyntia; Aminian, Kamiar; Pichonnaz, Claude; Farron, Alain; Jolles, Brigitte M; Bassin, Jean-Philippe

    2014-01-01

    Shoulder disorders, including rotator cuff tears, affect the shoulder function and result in adapted muscle activation. Although these adaptations have been studied in controlled conditions, free-living activities have not been investigated. Based on the kinematics measured with inertial sensors and portable electromyography, the objectives of this study were to quantify the duration of the muscular activation in the upper trapezius (UT), medial deltoid (MD) and biceps brachii (BB) during motion and to investigate the effect of rotator cuff tear in laboratory settings and daily conditions. The duration of movements and muscular activations were analysed separately and together using the relative time of activation (T EMG/mov ). Laboratory measurements showed the parameter’s reliability through movement repetitions (ICC > 0.74) and differences in painful shoulders compared with healthy ones (p < 0.05): longer activation for UT; longer activation for MD during abduction and tendency to shorter activation in other movements; shorter activation for BB. In daily conditions, T EMG/mov for UT was longer, whereas it was shorter for MD and BB (p < 0.05). Moreover, significant correlations were observed between these parameters and clinical scores. This study thus provides new insights into the rotator cuff tear effect on duration of muscular activation in daily activity. (paper)

  7. Comparison of Efficiencies of Michigan Neuropathy Screening Instrument, Neurothesiometer, and Electromyography for Diagnosis of Diabetic Neuropathy

    Directory of Open Access Journals (Sweden)

    Turkan Mete

    2013-01-01

    Full Text Available Aim. This study compares the effectiveness of Michigan Neuropathy Screening Instrument (MNSI, neurothesiometer, and electromyography (EMG in detecting diabetic peripheral neuropathy in patients with diabetes type 2. Materials and Methods. 106 patients with diabetes type 2 treated at the outpatient clinic of Ankara Numune Education and Research Hospital Department of Endocrinology between September 2008 and May 2009 were included in this study. Patients were evaluated by glycemic regulation tests, MNSI (questionnaire and physical examination, EMG (for detecting sensorial and motor defects in right median, ulnar, posterior tibial, and bilateral sural nerves, and neurothesiometer (for detecting alterations in cold and warm sensations as well as vibratory sensations. Results. According to the MNSI score, there was diabetic peripheral neuropathy in 34 (32.1% patients (score ≥2.5. However, when the patients were evaluated by EMG and neurothesiometer, neurological impairments were detected in 49 (46.2% and 79 (74.5% patients, respectively. Conclusion. According to our findings, questionnaires and physical examination often present lower diabetic peripheral neuropathy prevalence. Hence, we recommend that in the evaluation of diabetic patients neurological tests should be used for more accurate results and thus early treatment options to prevent neuropathic complications.

  8. The Eligibility of Surface Electromyography in the Assessment of Paraspinal Muscles Fatigue Following Interventions in Patients with Chronic Low Back Pain: A Systematic Review

    OpenAIRE

    Nahid Rahmani; Mohammad Ali Mohseni-Bandpei; Iraj Abdollahi

    2013-01-01

    Objective: Evaluation of paraspinal muscles endurance in patients with chronic low back pain (LBP) seems to be of great importance. Many studies demonstrated that surface electromyography has merit to assess muscle fatigue using frequency spectrum. The purpose of this study was to systematically review the eligibility of the surface electromyography in the assessment of paraspinal muscles fatigue changes following different interventions in patients with chronic LBP. Materials & Methods: ...

  9. Effect of bidirectional rotation of an acupuncture needle at LI10 on acupuncture needle sensation and experimentally-induced contact heat pain in healthy human volunteers.

    Science.gov (United States)

    Benham, Alex; Johnson, Mark I

    2014-06-01

    There is insufficient evidence of a relationship between acupuncture needle sensations (de qi) and hypoalgesia. The aim of this study was to investigate the effects of bidirectional needle rotation at LI10 on acupuncture needle sensations and heat pain thresholds. Twenty-two healthy participants received one acupuncture needle at LI10 with bidirectional rotation of the needle in one experimental session and one acupuncture needle at LI10 with mock rotation in a separate session, in a randomised order. Measurements of heat pain thresholds were taken before needle insertion, during needle retention and 15 min after needle removal. At each measurement time point, participants rated needle sensations using the Massachusetts Acupuncture Sensation Scale (MASS) and a visual analogue scale (VAS) of overall intensity of needle sensation. Bidirectional needle rotation produced significantly higher scores for VAS, MASStotal, MASSpain and MASSsensation compared with mock rotation (all psensation and change in pain threshold after needling was only found when data from mock and rotation interventions were combined. Needle rotation increases the magnitude of hypoalgesia. There is tentative evidence that needle sensation may be associated with the amount of change in pain threshold. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Plasma treatment of mammalian vascular cells : A quantitative description

    NARCIS (Netherlands)

    Kieft, IE; Darios, D; Roks, AJM; Stoffels, E

    For the first time, quantitative data was obtained on plasma treatment of living mammalian cells. The nonthermal atmospheric discharge produced by the plasma needle was used for treatment of mammalian endothelial and smooth muscle cells. The influence of several experimental parameters on cell

  11. Plasma treatment of mammalian vascular cells: a quantitative description

    NARCIS (Netherlands)

    Kieft, I.E.; Darios, D.; Roks, A.J.M.; Stoffels - Adamowicz, E.

    2005-01-01

    For the first time, quantitative data was obtained on plasma treatment of living mammalian cells. The nonthermal atmospheric discharge produced by the plasma needle was used for treatment of mammalian endothelial and smooth muscle cells. The influence of several experimental parameters on cell

  12. [Acupuncture therapy for regaining consciousness in terms of acupoint location, needle insertion and needle manipulation].

    Science.gov (United States)

    Meng, Xianggang; Gu, Wenlong; Ma, Fen; Du, Yuzheng; Zhao, Qi

    2015-03-01

    Acupuncture therapy for regaining consciousness activates soreness, numbness, distention, heaviness, radiating and moving, electric shock and ant climbing sensations at the specific acupoints in the stroke patients. Radiating and moving sensations are the summary of needling sensations such as soreness, numbness and twitching presenting during lifting and thrusting manipulation. These sensations are the essential factors of the therapeutic effect of regaining consciousness. Radiating sensation refers to the conduction along meridians and radiation of soreness and numbness. Moving sensation refers to the local muscular twitching at acupoints and the involuntary movement of limbs, joints and the distal. Acupuncture at the specific acupoints achieves radiating and moving sensations for promoting the circulation in meridians, regulating qi and mind and balancing yin and yang in stroke patients. This therapy was introduced in the paper in view of acupoint location, needle insertion and manipulation.

  13. Shikimate dehydrogenase from Pinu sylvestris L. needles

    International Nuclear Information System (INIS)

    Osipov, V.I.; Shein, I.V.

    1986-01-01

    Shikimate dehydrogenase was isolated by extraction from pine needles and partially purified by fractionation with ammonium sulfate. In conifers, in contrast to other plants, all three isoenzymes of shikimate dehydrogenase exhibit activity not only with NADP + , but also with NAD + . The values of K/sub m/ for shikimate, when NADP + and NAD + are used as cofactors, are 0.22 and 1.13 mM, respectively. The enzyme is maximally active at pH 10 with both cofactors. It is suggested that NAD-dependent shikimate dehydrogenase catalyzes the initial reaction of the alternative pathway of the conversion of shikimic acid to hydroxybenzoic acid. The peculiarities of the organization and regulation of the initial reactions of the shikimate pathway in conifers and in plants with shikimate dehydrogenase absolutely specific for NADP are discussed

  14. Emergency percutaneous needle decompression for tension pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Körner Markus

    2011-05-01

    Full Text Available Abstract Background Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic. Methods This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension. Results Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs, between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs. Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion, bridging the time to the start of the operation. Conclusions Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no

  15. Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method

    Directory of Open Access Journals (Sweden)

    Keyun Chen

    2016-09-01

    Full Text Available Micro-needle electrodes (MEs have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII, electromyography (EMG and electrocardiography (ECG recording. A magnetization-induced self-assembling method (MSM was developed to fabricate a microneedle array (MA. A MA coated with Ti/Au film was assembled as a ME. The fracture and insertion properties of ME were tested by experiments. The bio-signal recording performance of the ME was measured and compared with a typical commercial wet electrode (Ag/AgCl electrode. The results show that the MA self-assembled from the magnetic droplet array under the sum of gravitational surface tension and magnetic potential energies. The ME had good toughness and could easily pierce rabbit skin without being broken or buckling. When the compression force applied on the ME was larger than 2 N, ME could stably record EII, which was a lower value than that measured by Ag/AgCl electrodes. EMG signals collected by ME varied along with the contraction of biceps brachii muscle. ME could record static ECG signals with a larger amplitude and dynamic ECG signals with more distinguishable features in comparison with a Ag/AgCl electrode, therefore, ME is an alternative electrode for bio-signal monitoring in some specific situations.

  16. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  17. Return Rates for Needle Exchange Programs: A Common Criticism Answered

    Directory of Open Access Journals (Sweden)

    Ksobiech Kate

    2004-04-01

    Full Text Available Abstract This study searched the available needle exchange program (NEP literature for return rate data. A total of 26 articles were found. The overall worldwide return rate was 90%, although this ranged from a low of 15% to a high of 112%. U.S. NEP return rates were gathered from only eight studies, indicating a clear need for more data, although U.S. return rates were comparable to those from NEPs outside of the U.S. One underlying assumption made by opponents of NEPs is that IDUs will not return needles to the distribution site, thereby potentially increasing the risk of health problems to the surrounding community from exposure to contaminated needles. This study's results suggest that NEPs are relatively successful in taking in used needles, although it is generally unclear where the needles were originally acquired, and if IDUs return their own needles, or are returning needles for a social network. Ways for AIDS Service Organizations to capitalize on these brief encounters with IDUs, as well as public policy implications of the findings, are discussed.

  18. In vivo Monitoring of Serotonin by Nanomaterial Functionalized Acupuncture Needle

    Science.gov (United States)

    Li, Yu-Tao; Tang, Li-Na; Ning, Yong; Shu, Qing; Liang, Feng-Xia; Wang, Hua; Zhang, Guo-Jun

    2016-06-01

    Acupuncture treatment is amazing but controversial. Up to now, the mechanism of treating diseases by acupuncture and moxibustion is still unclear, especially the occurrence of the molecular events in local acupoints. Herein, we report an extremely stable microsensor by modifying carbon nanotube (CNT) to the tip surface of acupuncture needle and applying this CNT-modified acupuncture needle for real time monitoring of serotonin (5-HT) in vivo. To stabilize CNT modification on the needle tip surface, poly(3,4-ethylenedioxythiophene)(PEDOT) was employed as glue water to stick CNT on the needle. The detection limit of the CNT-modified needle was found to be approximately 50 nM and 78 nM in the PBS and the cell medium, respectively. In addition, the needle showed good selectivity to some inflammatory mediators and some electroactive molecules. For the first time, the CNT-modified needle could be directly probed into rat body for real time monitoring of 5-HT in vivo, showing a great potential for better understanding the mechanism of acupuncture treatment.

  19. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Diagenesis of conifer needles in a coastal marine environment

    Science.gov (United States)

    Hedges, John I.; Weliky, K.

    1989-10-01

    Physically intact fir, hemlock and cedar needles were isolated from different horizons of a sediment core from a coastal marine bay (Dabob Bay, Washington State, U.S.A.) and from nearby trees and forest litter. Green fir, hemlock and cedar needles were all characterized by glucose-rich aldose mixtures (~30% of tissue carbon), the production of vanillyl and cinnamyl CuO-derived phenols (~8% of tissue carbon) and the presence of both pinitol and myo-inositol (1-2% of tissue carbon). Needles from forest litter were enriched in lignin phenols and non-glucose aldoses and depleted in glucose and cyclitols. The sediment core contained an average of 10 mg/1 of physically intact fir, hemlock and cedar needles, which occurred in similar relative abundances and accounted for less than 1% of the total nonwoody gymnosperm tissue. Compared to the green and litter counterparts, all sedimentary needles were greatly depleted in cyclitols, glucose and p-coumaric acid and enriched in vanillyl phenol precursors. The degree of elevation of vanillyl phenol yield from the degraded needles was used to estimate minimal carbon losses from the samples, which ranged from near 40% for needle litter to almost 70% for the deepest (~100 years old) sedimentary fir/hemlock samples. Although downcore increases in carbon loss and refractory organic components indicated in situ diagenesis, the bulk of overall degradation occurred either on land or during the first 10-20 years after deposition. Atomic C/N ratios of degraded needles were lower than for green counterparts, but nitrogen was lost overall. These relative changes indicate the following stability series: vanillyl phenols > N > ferulic acid, p-hydroxy phenols, most aldoses and bulk tissue > glucose and p-coumaric acid > cyclitols (near 100% loss). Vanillic acid to vanillin ratios, (Ad/Al)v, of the green fir and hemlock needles were unusually high (0.36-0.38) and decreased downcore. Diagenesis also decreased the cinnamyl/vanillyl phenol ratio

  1. The Comparing the Leg Muscles Electromyography during Single Leg Drop Landing in Pesplanus and Normal Men

    Directory of Open Access Journals (Sweden)

    mostafa bazvand

    2016-03-01

    Full Text Available Objective: pesplanus is one of the changes that brings about changes in muscle activation patterns. Being aware of muscles activity changes in various standing positions among pesplanus patients provides insights into preventing lower extremity injuries in this population. The aim of this study was to compare leg muscles electromyography during various standing positions in pesplanus and normal subjects. Methods: 60 healthy male university students, 30 subjects with pesplanus deformity (with average age 23/54±3/57 year, average height 175/34±7/62 cm, average weight 74/87±10/72 kg and 30 normal subjects (with average age 22/97±2/38 year, average height 176/6±5/59 cm, average weight 73/58±8/36 kg participated in this comparative study. Deformity of pesplanus was assessed with navicular drop test. Each subject performed single-leg landing dropping from 30cm height onto a force platform where muscles activity was recorded with EMG device. For data analysis, Matlab and Spss softwares were used and independent sample t-test was used to compare the dependent variables at a significance level of P &le 0/05. Results: Significant differences were observed between the two groups for the activities of the longus peroneus and anterior tibialis muscles ( p&le0/05 while no significant differences were observed in other muscles. Conclusion: The changes in the normal structure of the foot might affect muscle activities during standing, which can cause changes in the injury patterns. Therefore, it is proposed that focusing on corrective exercises and therapy plan can reduce these risks.

  2. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    Science.gov (United States)

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  3. Electromyography analysis of natural mastication behavior using varying mouthful quantities of two types of gels.

    Science.gov (United States)

    Kohyama, Kaoru; Gao, Zhihong; Ishihara, Sayaka; Funami, Takahiro; Nishinari, Katsuyoshi

    2016-07-01

    The objectives of this study were to examine the effects of mouthful quantities and mechanical properties of gels on natural mastication behaviors using electromyography (EMG). Two types of hydrocolloid gels (A and K) with similar fracture loads but different moduli and fracture strains were served to eleven normal women in 3-, 6-, 12-, and 24-g masses in a randomized order. EMG activities from both masseter muscles were recorded during natural mastication. Because of the similar fracture loads, the numbers of chews, total muscle activities, and entire oral processing times were similar for similar masses of both gel types. Prior to the first swallow, the more elastic K gel with a higher fracture strain required higher muscle activities than the brittle A gel, which had higher modulus. Majority of subjects had preferred sides of chewing, but all subjects with or without preferred sides used both masseters during the consumption of gels. Similar effects of masses and types of gels were observed in EMG activities of both sides of masseters. Contributions of the dominant side of chewing were diminished with increasing masses of gels, and the mass dependency on ratio of the dominant side was more pronounced with K gel. More repetitions of smaller masses required greater muscle activities and longer periods for the consumption of 24-g gel portions. Reduction in the masses with an increased number of repetitions necessitated slower eating and more mastication to consume the gel portions. These observations suggest that chewing using both sides is more effective and unconsciously reduces mastication times during the consumption of gels. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    Science.gov (United States)

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Surface electromyography and ultrasound evaluation of pelvic floor muscles in hyperandrogenic women.

    Science.gov (United States)

    Vassimon, Flávia Ignácio Antonio; Ferreira, Cristine Homsi Jorge; Martins, Wellington Paula; Ferriani, Rui Alberto; Batista, Roberta Leopoldino de Andrade; Bo, Kari

    2016-04-01

    High levels of androgens increase muscle mass. Due to the characteristics of hyperandrogenism in polycystic ovary syndrome (PCOS), it is plausible that women with PCOS may have increased pelvic floor muscle (PFM) thickness and neuromuscular activity levels compared with controls. The aim of this study was to assess PFM thickness and neuromuscular activity among hyperandrogenic women with PCOS and controls. This was an observational, cross-sectional, case-control study evaluating PFM by ultrasound (US) and surface electromyography (sEMG) in nonobese women with and without PCOS. Seventy-two women were divided into two groups: PCOS (n = 33) and controls (n = 39). PFM thickness during contraction was assessed by US (Vingmed CFM 800). Pelvic floor muscle activity was assessed by sEMG (MyoTrac Infinit) during contractions at different time lengths: quick, and 8 and 60 s. Descriptive analysis, analysis of variance (ANOVA), and Student's t test were used for statistical analyses. There were no significant differences in PFM sEMG activity between PCOS and controls in any of the contractions: quick contraction (73.23 mV/ 71.56 mV; p = 0.62), 8 s (55.77 mV/ 54.17 mV; p = 0.74), and 60 s (49.26 mV/ 47.32 mV; p = 0.68), respectively. There was no difference in PFM thickness during contractions evaluated by US between PCOS and controls (12.78 mm/ 13.43 mm; p =  .48). This study did not find statistically significant differences in pelvic floor muscle thickness or in muscle activity between PCOS women and controls.

  6. Validity and Reliability of Surface Electromyography in the Assessment of Primary Muscle Tension Dysphonia.

    Science.gov (United States)

    Khoddami, Seyyedeh Maryam; Talebian, Saeed; Izadi, Farzad; Ansari, Noureddin Nakhostin

    2017-05-01

    The study aims to evaluate the reliability and the discriminative validity of surface electromyography (sEMG) in the assessment of patients with primary muscle tension dysphonia (MTD). The study design is cross-sectional. Fifteen patients with primary MTD (mean age: 34.07 ± 10.99 years) and 15 healthy volunteers (mean age: 34.53 ± 10.63 years) were included. All participants underwent evaluation of sEMG to record the electrical activity of the thyrohyoid and cricothyroid muscles. The outcome measures were the root mean square (RMS), activity peak, duration, and time to the peak activity, which were obtained during /a/ and /i/ prolongation for test-retest reliability. The test-retest reliability was good to excellent for the RMS and peak activity measures (intraclass correlation coefficient [agreement] [ICC agreement ] = 0.49-0.98). The reliability for the activity duration was poor to excellent (ICC agreement  = 0.19-0.9). Poor test-retest reliability was found for the time to peak measure (ICC agreement  = 0.15-0.37). The standard error of measurement for all sEMG measures was between 0.41 and 2.05. The smallest detectable change (SDC) was calculated between 1.13 and 5.66. The highest SDC values were obtained for the peak and the lowest SDCs were documented for the duration (5.66 and 1.13, respectively). All sEMG measures were not able to discriminate between the MTD patients and healthy subjects (P > 0.05). The sEMG is a reliable tool to measure the RMS, the peak activity, and the activity duration in primary MTD. However, it is not able to discriminate the patients with primary MTD from healthy subjects. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  7. A systematic review of surface electromyography analyses of the bench press movement task.

    Directory of Open Access Journals (Sweden)

    Petr Stastny

    Full Text Available The bench press exercise (BP plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed?PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered.The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB and pectoralis major (PM muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change.PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits or guidelines for the use of exact muscle models.

  8. A systematic review of surface electromyography analyses of the bench press movement task.

    Science.gov (United States)

    Stastny, Petr; Gołaś, Artur; Blazek, Dusan; Maszczyk, Adam; Wilk, Michał; Pietraszewski, Przemysław; Petr, Miroslav; Uhlir, Petr; Zając, Adam

    2017-01-01

    The bench press exercise (BP) plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG) studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed? PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered. The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB) and pectoralis major (PM) muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change. PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits) or guidelines for the use of exact muscle models.

  9. Analysis of Muscle Contraction on Pottery Manufacturing Process Using Electromyography (EMG)

    Science.gov (United States)

    Soewardi, Hartomo; Azka Rahmayani, Amalia

    2016-01-01

    One of the most common problems in pottery manufacturing process is musculoskeletal disorders on workers. This disorder was caused by uncomfortable posture where the workers sit on the floor with one leg was folded and another was twisted for long duration. Back, waist, buttock, and right knee frequently experience the disorders. The objective of this research is to investigate the muscle contraction at such body part of workers in manufacturing process of pottery. Electromyography is used to investigate the muscle contraction based on the median frequency signal. Focus measurements is conducted on four muscles types. They are lower interscapular muscle on the right and left side, dorsal lumbar muscle, and lateral hamstring muscle. Statistical analysis is conducted to test differences of muscle contraction between female and male. The result of this research showed that the muscle which reached the highest contraction is dorsal lumbar muscle with the average of median frequency is 51,84 Hz. Then followed by lower interscapular muscle on the left side with the average of median frequency is 31,30 hz, lower interscapular muscle on the right side average of median frequency is 31,24 Hz, and lateral hamstring muscle average of median frequency is 21,77 Hz. Based on the statistic analysis result, there were no differences between male and female on left and right lower interscapular muscle and dorsal lumbar muscle but there were differences on lateral hamstring muscle with the significance level is 5%. Besides that, there were differences for all combination muscle types with the level of significance is 5%.

  10. Electromyography-controlled exoskeletal upper-limb-powered orthosis for exercise training after stroke.

    Science.gov (United States)

    Stein, Joel; Narendran, Kailas; McBean, John; Krebs, Kathryn; Hughes, Richard

    2007-04-01

    Robot-assisted exercise shows promise as a means of providing exercise therapy for weakness that results from stroke or other neurological conditions. Exoskeletal or "wearable" robots can, in principle, provide therapeutic exercise and/or function as powered orthoses to help compensate for chronic weakness. We describe a novel electromyography (EMG)-controlled exoskeletal robotic brace for the elbow (the active joint brace) and the results of a pilot study conducted using this brace for exercise training in individuals with chronic hemiparesis after stroke. Eight stroke survivors with severe chronic hemiparesis were enrolled in this pilot study. One subject withdrew from the study because of scheduling conflicts. A second subject was unable to participate in the training protocol because of insufficient surface EMG activity to control the active joint brace. The six remaining subjects each underwent 18 hrs of exercise training using the device for a period of 6 wks. Outcome measures included the upper-extremity component of the Fugl-Meyer scale and the modified Ashworth scale of muscle hypertonicity. Analysis revealed that the mean upper-extremity component of the Fugl-Meyer scale increased from 15.5 (SD 3.88) to 19 (SD 3.95) (P = 0.04) at the conclusion of training for the six subjects who completed training. Combined (summated) modified Ashworth scale for the elbow flexors and extensors improved from 4.67 (+/-1.2 SD) to 2.33 (+/-0.653 SD) (P = 0.009) and improved for the entire upper limb as well. All subjects tolerated the device, and no complications occurred. EMG-controlled powered elbow orthoses can be successfully controlled by severely impaired hemiparetic stroke survivors. This technique shows promise as a new modality for assisted exercise training after stroke.

  11. Continuous Wavelet Transform Analysis of Surface Electromyography for Muscle Fatigue Assessment on the Elbow Joint Motion

    Directory of Open Access Journals (Sweden)

    Triwiyanto Triwiyanto

    2017-01-01

    Full Text Available Studying muscle fatigue plays an important role in preventing the risks associated with musculoskeletal disorders. The effect of elbow-joint angle on time-frequency parameters during a repetitive motion provides valuable information in finding the most accurate position of the angle causing muscle fatigue. Therefore, the purpose of this study is to analyze the effect of muscle fatigue on the spectral and time-frequency domain parameters derived from electromyography (EMG signals using the Continuous Wavelet Transform (CWT. Four male participants were recruited to perform a repetitive motion (flexion and extension movements from a non-fatigue to fatigue condition. EMG signals were recorded from the biceps muscle. The recorded EMG signals were then analyzed offline using the complex Morlet wavelet. The time-frequency domain data were analyzed using the time-averaged wavelet spectrum (TAWS and the Scale-Average Wavelet Power (SAWP parameters. The spectral domain data were analyzed using the Instantaneous Mean Frequency (IMNF and the Instantaneous Mean Power Spectrum (IMNP parameters. The index of muscle fatigue was observed by calculating the increase of the IMNP and the decrease of the IMNF parameters. After performing a repetitive motion from non-fatigue to fatigue condition, the average of the IMNF value decreased by 15.69% and the average of the IMNP values increased by 84%, respectively. This study suggests that the reliable frequency band to detect muscle fatigue is 31.10-36.19Hz with linear regression parameters of 0.979mV^2Hz^(-1 and 0.0095mV^2Hz^(-1 for R^2 and slope, respectively.

  12. Fatigue effects upon sticking region and electromyography in a six-repetition maximum bench press.

    Science.gov (United States)

    van den Tillaar, Roland; Saeterbakken, Atle Hole

    2013-01-01

    The aim of the study was to examine the sticking region and concomitant neuromuscular activation of the prime movers during six-repetition maximum (RM) bench pressing. We hypothesised that both peak velocities would decrease and that the electromyography (EMG) of the prime movers (deltoid, major pectoralis and triceps) would increase during the pre-sticking and sticking region during the six repetitions due to fatigue. Thirteen resistance-trained males (age 22.8 ± 2.2 years, stature 1.82 ± 0.06 m, body mass 83.4 ± 7.6 kg) performed 6-RM bench presses. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, and triceps brachii during the pre-, sticking and post-sticking region of each repetition in a 6-RM bench press were analysed. For both the sticking as the post-sticking region, the time increased significantly from the first to the sixth repetition. Vertical barbell height at the start of sticking region was lower, while the height at the end of the sticking region and post-sticking region did not change during the six repetitions. It was concluded that in 6-RM bench pressing performance, the sticking region is a poor mechanical force region due to the unchanged barbell height at the end of the sticking region. Furthermore, when fatigue occurs, the pectoralis and the deltoid muscles are responsible for surpassing the sticking region as indicated by their increased activity during the pre- and sticking region during the six-repetitions bench press.

  13. Neck Kinematics and Electromyography While Wearing Head Supported Mass During Running.

    Science.gov (United States)

    Hanks, Matthew M; Sefton, JoEllen M; Oliver, Gretchen D

    2018-01-01

    Advanced combat helmets (ACH) coupled with night-vision goggles (NVG) are required for tactical athletes during training and service. Head and neck injuries due to head supported mass (HSM) are a common occurrence in military personnel. The current study aimed to investigate the effects of HSM on neck muscle fatigue that may lead to chronic stress and injury of the head and neck. Subjects wore an ACH and were affixed with electromagnetic sensors to obtain kinematic data, as well as EMG electrodes to obtain muscle activations of bilateral sternocleidomastoid, upper trapezius, and paraspinal muscles while running on a treadmill. Subjects performed a 2-min warmup at a walking pace, a 5-min warmup jog, running at a pace equal to 90% maximum heart rate until absolute fatigue, and lastly a 2-min cooldown at a walking pace. Kinematic and EMG data were collected over each 2-min interval. Days later, the same subjects wore the same ACH in addition to the NVG and performed the same protocol as the first session. This study showed significant differences in muscle activation of the right upper trapezius [F(1,31) = 10.100] and both sternocleidomastoid [F(1,31) = 12.280] muscles from pre-fatigue to absolute fatigue. There were no significant differences noted in the kinematic variables. This study suggests that HSM can fatigue bilateral neck flexors and rotators, as well as fatigue the neck extensors and rotators on the contralateral side of the mounted NVG.Hanks MM, Sefton JM, Oliver GD. Neck kinematics and electromyography while wearing head supported mass during running. Aerosp Med Hum Perform. 2018; 89(1):9-13.

  14. Single-fiber electromyography analysis of botulinum toxin diffusion in patients with fatigue and pseudobotulism.

    Science.gov (United States)

    Ruet, Alexis; Durand, Marie Christine; Denys, Pierre; Lofaso, Frederic; Genet, François; Schnitzler, Alexis

    2015-06-01

    To characterize electromyographic abnormalities according to symptoms (asymptomatic, fatigue, pseudobotulism) reported 1 month after botulinum toxin injection. Retrospective, single-center study comparing single-fiber electromyography (SFEMG) in the extensor digitorum communis (EDC) or orbicularis oculi (OO) muscles. Hospital. Four groups of adults treated for spasticity or neurologic bladder hyperactivity (N=55): control group (asymptomatic patients: n=17), fatigue group (unusual fatigue with no weakness: n=15), pseudobotulism group (muscle weakness and/or visual disturbance: n=20), and botulism group (from intensive care unit of the same hospital: n=3). Not applicable. Mean jitter, percentage of pathologic fibers, and percentage of blocked fibers were compared between groups. SFEMG was abnormal for 17.6% of control patients and 75% of patients in the pseudobotulism group. There were no differences between the control and fatigue groups. Mean jitter, percentage of pathologic fibers, and percentage of blocked fibers of the EDC muscle were significantly higher in the pseudobotulism group than in the fatigue and control groups. There were no differences between groups for the OO muscle. The SFEMG results in the botulism group were qualitatively similar to those of the pseudobotulism group. SFEMG of the EDC muscle confirmed diffusion of the toxin into muscles distant from the injection site in the pseudobotulism group. SFEMG in the OO muscle is not useful for the diagnosis of diffusion. No major signs of diffusion of botulinum toxin type A were found away from the injection site in patients with fatigue but no motor weakness. Such fatigue may be related to other mechanisms. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. A systematic review of surface electromyography analyses of the bench press movement task

    Science.gov (United States)

    Gołaś, Artur; Blazek, Dusan; Maszczyk, Adam; Wilk, Michał; Pietraszewski, Przemysław; Petr, Miroslav; Uhlir, Petr; Zając, Adam

    2017-01-01

    Background The bench press exercise (BP) plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG) studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed? Strategy PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered. Results The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB) and pectoralis major (PM) muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change. Conclusions PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits) or guidelines for the use of exact muscle models. PMID

  16. Analysis of Muscle Fatigue Progression using Cyclostationary Property of Surface Electromyography Signals.

    Science.gov (United States)

    Karthick, P A; Venugopal, G; Ramakrishnan, S

    2016-01-01

    Analysis of neuromuscular fatigue finds various applications ranging from clinical studies to biomechanics. Surface electromyography (sEMG) signals are widely used for these studies due to its non-invasiveness. During cyclic dynamic contractions, these signals are nonstationary and cyclostationary. In recent years, several nonstationary methods have been employed for the muscle fatigue analysis. However, cyclostationary based approach is not well established for the assessment of muscle fatigue. In this work, cyclostationarity associated with the biceps brachii muscle fatigue progression is analyzed using sEMG signals and Spectral Correlation Density (SCD) functions. Signals are recorded from fifty healthy adult volunteers during dynamic contractions under a prescribed protocol. These signals are preprocessed and are divided into three segments, namely, non-fatigue, first muscle discomfort and fatigue zones. Then SCD is estimated using fast Fourier transform accumulation method. Further, Cyclic Frequency Spectral Density (CFSD) is calculated from the SCD spectrum. Two features, namely, cyclic frequency spectral area (CFSA) and cyclic frequency spectral entropy (CFSE) are proposed to study the progression of muscle fatigue. Additionally, degree of cyclostationarity (DCS) is computed to quantify the amount of cyclostationarity present in the signals. Results show that there is a progressive increase in cyclostationary during the progression of muscle fatigue. CFSA shows an increasing trend in muscle fatiguing contraction. However, CFSE shows a decreasing trend. It is observed that when the muscle progresses from non-fatigue to fatigue condition, the mean DCS of fifty subjects increases from 0.016 to 0.99. All the extracted features found to be distinct and statistically significant in the three zones of muscle contraction (p < 0.05). It appears that these SCD features could be useful in the automated analysis of sEMG signals for different neuromuscular conditions.

  17. Muscle fatigue in women with primary biliary cirrhosis: Spectral analysis of surface electromyography

    Science.gov (United States)

    Biagini, Maria Rosa; Tozzi, Alessandro; Grippo, Antonello; Galli, Andrea; Milani, Stefano; Amantini, Aldo

    2006-01-01

    AIM: To evaluate the myoelectric manifestations of peripheral fatigability in patients with primary biliary cirrhosis in comparison to healthy subjects. METHODS: Sixteen women with primary biliary cirrhosis without comorbidity and 13 healthy women matched for age and body mass index (BMI) completed the self-reported questionnaire fatigue impact scale. All subjects underwent surface electromyography assessment of peripheral fatigability. Anterior tibial muscle isometric voluntary contraction was executed for 20 s at 80% of maximal voluntary isometric contraction. During the exercise electromyographic signal series were recorded and root mean square (expression of central drive) as well as mean and median of electromyographic signal frequency spectrum (estimates of muscle fatigability) were computed. Each subject executed the trial two times. EMG parameters were normalized, then linear regression was applied and slopes were calculated. RESULTS: Seven patients were fatigued (median fatigue impact scale score: 38, range: 26-66) and 9 were not fatigued (median fatigue impact scale score: 7, range: 0-17). The maximal voluntary isometric contraction was similar in patients (82, 54-115 N) and controls (87, 74-101 N), and in patients with high (81, 54-115 N) and low fatigue impact scale scores (86, 65-106 N). Root mean square as well as mean and median of frequency spectrum slopes were compared with the Mann-Whitney U test, and no significant difference was found between fatigued and non-fatigued patients and controls. CONCLUSION: No instrumental evidence of peripheral fatigability can be found in women with primary biliary cirrhosis but no comorbidity, suggesting that fatigue in such patients may be of central origin. PMID:16937530

  18. Evaluation of surgeon's muscle fatigue during thoracoscopic pulmonary lobectomy using interoperative surface electromyography.

    Science.gov (United States)

    Yoon, Seung-Hyun; Jung, Myung-Chul; Park, Seong Yong

    2016-06-01

    The aim of this study was to document the physical stress experienced by a surgeon during thoracoscopic pulmonary lobectomy and mediastinal lymph node dissection for lung cancer by measuring the intraoperative electromyography (EMG). Surface EMG was recorded during 12 cases of thoracoscopic lobectomy. During the operation, 16 channels of a wireless EMG were used to measure muscle activity and fatigue from the bilateral muscles of the splenius capitis (SC), upper trapezius (UT), middle deltoid (MD), flexor carpi radialis (FCR), extensor carpi radialis (ECR), lumbar erector spinae (LES), rectus femoralis (RF), and tibialis anterior (TA). The EMG signals were processed to collect the values of the root mean square for muscle activity and median frequency (MF) for muscle fatigue. All operations were completed without adverse events. The mean operating time was 99.16±35.15 minutes. During the operation, the mean muscle activity of all muscles was 21.91±12.85 mV. High muscle activity was observed in the bilateral FCR and ECR, whereas low muscle activity was observed in the bilateral SC and LES. The final MFs in the bilateral SC and LES were found to be decreased from the initial status, which implied increased muscle fatigue. The muscles of the right and left LES were significantly fatigued by up to 29% and 37% compared to their initial status (P=0.021 and P=0.007, respectively). The MFs of the bilateral LES decreased with time (an average decreases of 0.008/5 minutes, P=0.002 in right LES and 0.004/5 minutes, P=0.018 in left LES). During thoracoscopic lobectomy, muscle fatigue was observed in muscles related to a static posture, such as the bilateral SC, UT, and ES. Further studies are required to investigate the ergonomic adjustments needed to reduce muscle fatigue in these static muscles.

  19. Classification of Anticipatory Signals for Grasp and Release from Surface Electromyography

    Science.gov (United States)

    Siu, Ho Chit; Shah, Julie A.; Stirling, Leia A.

    2016-01-01

    Surface electromyography (sEMG) is a technique for recording natural muscle activation signals, which can serve as control inputs for exoskeletons and prosthetic devices. Previous experiments have incorporated these signals using both classical and pattern-recognition control methods in order to actuate such devices. We used the results of an experiment incorporating grasp and release actions with object contact to develop an intent-recognition system based on Gaussian mixture models (GMM) and continuous-emission hidden Markov models (HMM) of sEMG data. We tested this system with data collected from 16 individuals using a forearm band with distributed sEMG sensors. The data contain trials with shifted band alignments to assess robustness to sensor placement. This study evaluated and found that pattern-recognition-based methods could classify transient anticipatory sEMG signals in the presence of shifted sensor placement and object contact. With the best-performing classifier, the effect of label lengths in the training data was also examined. A mean classification accuracy of 75.96% was achieved through a unigram HMM method with five mixture components. Classification accuracy on different sub-movements was found to be limited by the length of the shortest sub-movement, which means that shorter sub-movements within dynamic sequences require larger training sets to be classified correctly. This classification of user intent is a potential control mechanism for a dynamic grasping task involving user contact with external objects and noise. Further work is required to test its performance as part of an exoskeleton controller, which involves contact with actuated external surfaces. PMID:27792155

  20. Comparison of regression models for estimation of isometric wrist joint torques using surface electromyography

    Directory of Open Access Journals (Sweden)

    Menon Carlo

    2011-09-01

    Full Text Available Abstract Background Several regression models have been proposed for estimation of isometric joint torque using surface electromyography (SEMG signals. Common issues related to torque estimation models are degradation of model accuracy with passage of time, electrode displacement, and alteration of limb posture. This work compares the performance of the most commonly used regression models under these circumstances, in order to assist researchers with identifying the most appropriate model for a specific biomedical application. Methods Eleven healthy volunteers participated in this study. A custom-built rig, equipped with a torque sensor, was used to measure isometric torque as each volunteer flexed and extended his wrist. SEMG signals from eight forearm muscles, in addition to wrist joint torque data were gathered during the experiment. Additional data were gathered one hour and twenty-four hours following the completion of the first data gathering session, for the purpose of evaluating the effects of passage of time and electrode displacement on accuracy of models. Acquired SEMG signals were filtered, rectified, normalized and then fed to models for training. Results It was shown that mean adjusted coefficient of determination (Ra2 values decrease between 20%-35% for different models after one hour while altering arm posture decreased mean Ra2 values between 64% to 74% for different models. Conclusions Model estimation accuracy drops significantly with passage of time, electrode displacement, and alteration of limb posture. Therefore model retraining is crucial for preserving estimation accuracy. Data resampling can significantly reduce model training time without losing estimation accuracy. Among the models compared, ordinary least squares linear regression model (OLS was shown to have high isometric torque estimation accuracy combined with very short training times.

  1. Electromyography findings of the cricopharyngeus in association with ipsilateral pharyngeal and laryngeal muscles.

    Science.gov (United States)

    Halum, Stacey L; Shemirani, Nima L; Merati, Albert L; Jaradeh, Safwan; Toohill, Robert J

    2006-04-01

    We reviewed a large series of cricopharyngeal (CP) muscle electromyography (EMG) results and compared them with the EMG results from the inferior constrictor (IC), thyroarytenoid, (TA), cricothyroid (CT), and posterior cricoarytenoid (PCA) muscles. We performed a retrospective review of all CP muscle EMG reports from studies performed between January 1996 and June 2003. All of the tested elements from the CP muscle EMG reports were recorded. The EMG results were recorded for the ipsilateral IC, TA, CT, and PCA muscles if they were simultaneously tested. Each muscle result was classified as normal, neurogenic inactive axonal injury (IAI), or neurogenic active axonal injury (AAI), and the muscle findings were compared. A patient chart review was performed to determine a clinical correlation. Fifty-nine patients underwent CP muscle EMG. Eighteen patients had bilateral EMG studies, making a total of 77 CP muscle studies. Nineteen sets of CP muscle results were normal, 43 demonstrated neurogenic IAI, and 15 demonstrated neurogenic AAI. The ipsilateral IC and CP muscles had the same innervation status in 27 of 28 studies (p muscle was studied simultaneously with the CP muscle, 31 of 50 studies had the same innervation status (p = .005). The ipsilateral CT and CP muscles demonstrated the same innervation status in 40 of 50 studies (p muscle findings and between the CP and CT muscle findings were both stronger than the correlation between the CP and TA muscle findings (p muscle findings have the strongest correlation with IC muscle findings, followed by the CT and TA muscles. This outcome does not support theories indicating that the recurrent laryngeal nerve innervates the CP muscle in all cases.

  2. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver.

    Science.gov (United States)

    Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay

    2018-01-01

    The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  3. Accumulation of Cs 137 by needles of pinus silvestris in various types of forest

    International Nuclear Information System (INIS)

    Golushko, R.M.

    2002-01-01

    It is researched accumulation of Cs 137 by needles of pine trees during growing old. It is shown, that needles of the one year old have more high radioactivity than needles of the two or three years old. Needles of pine trees accumulated more Cs 137 on good wet soils

  4. Constructing seasonal LAI trajectory by data-model fusion for global evergreen needle-leaf forests

    Science.gov (United States)

    Wang, R.; Chen, J.; Mo, G.

    2010-12-01

    For decades, advancements in optical remote sensors made it possible to produce maps of a biophysical parameter--the Leaf Area Index (LAI), which is critically necessary in regional and global modeling of exchanges of carbon, water, energy and other substances, across large areas in a fast way. Quite a few global LAI products have been generated since 2000, e.g. GLOBCARBON (Deng et al., 2006), MODIS Collection 5 (Shabanov et al., 2007), CYCLOPES (Baret et al., 2007), etc. Albeit these progresses, the basic physics behind the technology restrains it from accurate estimation of LAI in winter, especially for northern high-latitude evergreen needle-leaf forests. Underestimation of winter LAI in these regions has been reported in literature (Yang et al., 2000; Cohen et al., 2003; Tian et al., 2004; Weiss et al., 2007; Pisek et al., 2007), and the distortion is usually attributed to the variations of canopy reflectance caused by understory change (Weiss et al., 2007) as well as by the presence of ice and snow on leaves and ground (Cohen, 2003; Tian et al., 2004). Seasonal changes in leaf pigments can also be another reason for low LAI retrieved in winter. Low conifer LAI values in winter retrieved from remote sensing make them unusable for surface energy budget calculations. To avoid these drawbacks of remote sensing approaches, we attempt to reconstruct the seasonal LAI trajectory through model-data fusion. A 1-degree LAI map of global evergreen needle-leaf forests at 10-day interval is produced based on the carbon allocation principle in trees. With net primary productivity (NPP) calculated by the Boreal Ecosystems Productivity Simulator (BEPS) (Chen et al., 1999), carbon allocated to needles is quantitatively evaluated and then can be further transformed into LAI using the specific leaf area (SLA). A leaf-fall scheme is developed to mimic the carbon loss caused by falling needles throughout the year. The seasonally maximum LAI from remote sensing data for each pixel

  5. Facile method to align crystalline needles composed of organic ...

    Indian Academy of Sciences (India)

    2017-09-23

    Sep 23, 2017 ... (using self-assembly) used for the purpose, its disadvantage is that a larger amount of the material dissolves in the solution than what ... Working hypothesis for aligning crystalline needles .... using a home-made equipment.

  6. NEEDLE ANATOMY CHANGES WITH INCREASING TREE AGE IN DOUGLAS FIR

    Science.gov (United States)

    Morphological differences between old growth and sapling (Pseudotsuga menziesii, (Mirb.) Franco) Douglas fir trees may extend to differences in needle anatomy. We used microscopy with image analysis to compare and quantify anatomical parameters in cross-sections of previous year...

  7. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  8. [Doctor HUANG Shi-ping's acupuncture with golden needles].

    Science.gov (United States)

    Chen, Teng-Fei; Ma, Zeng-Bin; Xin, Si-Yuan; Zhu, Jiang

    2013-08-01

    Taking Doctor HUANG Shi-ping as the representative, the school of Huang's golden needle is based on Chinese martial art. Golden needles are adopted as main tool. Attaching great importance on the combination of acupuncture and moxibustioin, it is also characterized with penetrating needling with long needles. Through the development of three generations, it once outshone other schools in the field of acupuncture, and became famous all over the world. It made great contribution to the development of the course of acupuncture. However, with the development of the history, the form of acupuncture education as well as apparatus were all undergone an unified reform. Therefore, Doctor HUANG Shi-ping's acupuncture school be lost gradually.

  9. High-pressure needle interface for thermoplastic microfluidics.

    Science.gov (United States)

    Chen, C F; Liu, J; Hromada, L P; Tsao, C W; Chang, C C; DeVoe, D L

    2009-01-07

    A robust and low dead volume world-to-chip interface for thermoplastic microfluidics has been developed. The high pressure fluidic port employs a stainless steel needle inserted into a mating hole aligned to an embedded microchannel, with an interference fit used to increase pressure resistance. Alternately, a self-tapping threaded needle screwed into a mating hole is also demonstrated. In both cases, the flat bottom needle ports seat directly against the microchannel substrate, ensuring low interfacial dead volumes. Low dispersion is observed for dye bands passing the interfaces. The needle ports offer sufficient pull-out forces for applications such as liquid chromatography that require high internal fluid pressures, with the epoxy-free interfaces compatible with internal microchannel pressures above 40 MPa.

  10. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  11. Susuks (charm needles) in the craniofacial region

    International Nuclear Information System (INIS)

    Nambiar, P.; Ibrahim, N.; Tandjung, Y.R.M.; Shanmuhasuntharam, P.

    2008-01-01

    We conducted a study to determine the numbers of susuks (charm needles) and their distribution in the craniofacial region of susuk wearers, and the sex, racial affiliation, and age of the wearers. In addition, we sought to determine whether the presence of susuks posed any potential hazard to patients undergoing magnetic resonance imaging (MRI). We studied various radiographs of 33 susuk wearers (age range, 33-69 years) and investigated the most common sites of insertion in the craniofacial region. A susuk was also suspended inside a 1.5-T MRI machine to determined whether it was attracted by the machine's magnet. The largest number of susuks that we observed in the craniofacial region was 39 pins, and susuks were particularly numerous in Malay Muslim women. Other sites with susuks were the maxillofacial region (except the temporomandibular region) and the forehead. The susuks showed no ferromagnetic characteristics. As susuks are made from gold, they are generally biocompatible with human tissue and do not cause problems to their wearers. Gold and the other minor metal constituents found in susuks have no ferromagnetic characteristics and therefore pose no hazard to patients undergoing MRI. (author)

  12. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  13. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  14. Fine needle aspiration cytology in leprosy

    Directory of Open Access Journals (Sweden)

    Prasad PVS

    2008-01-01

    Full Text Available Background: Laboratory diagnosis of leprosy by slit skin smear and skin biopsy is simple but both techniques have their own limitations. Slit skin smear is negative in paucibacillary cases whereas skin biopsy is an invasive technique. Fine needle aspiration cytology (FNAC from skin lesions in leprosy with subsequent staining with May-Grunwald-Giemsa (MGG stain has been found useful. Aim: To evaluate the possible role of cytology in classifying leprosy patients. Methods: Seventy-five untreated cases of leprosy attending the outpatient department were evaluated. Smears were taken from their skin lesions and stained using the MGG technique. Skin biopsy was also done from the lesions, which was compared with cytology smears. Results: A correlation of clinical features with FNAC was noticed in 87.5% of TT, 92.1% of BT, 81% of BL, and 66% of LL cases. Correlation of clinical with histopathological diagnoses revealed 12.5% specificity in TT leprosy, 55.3% in BT, 52.4% in BL and 50% in LL, and 100% in neuritic and histoid leprosy cases. Both correlations were found to be statistically significant by paired t test analysis. Thus, it was possible to distinguish the tuberculoid types by the presence of epithelioid cells and the lepromatous types by the presence of lymphocytes and foamy macrophages. Conclusion: FNAC may be used to categorize the patients into paucibacillary and multibacillary types, but is not a very sensitive tool to classify the patients across the Ridley-Jopling spectrum.

  15. Chondromalacia patellae treated by warming needle and rehabilitation training.

    Science.gov (United States)

    Qiu, Ling; Zhang, Min; Zhang, Ji; Gao, Le-Nv; Chen, Da-wei; Liu, Jun; She, Jia-yi; Wang, Ling; Yu, Jin-yan; Huang, Le-ping; Bai, Yang

    2009-06-01

    To observe the effect of warming needle combined with rehabilitation training on chondromalacia patellae in a randomized controlled trial. The 92 cases were randomly divided into a treatment group treated by warming needle plus rehabilitation training (47 cases) and a control group treated by medication plus rehabilitation training (45 cases), and the therapeutic effect was compared after 20 sessions. The pain was relieved more obviously in the treatment group than in the control group (P chondromalacia patellae.

  16. Two-miRNA classifiers differentiate mutation-negative follicular thyroid carcinomas and follicular thyroid adenomas in fine needle aspirations with high specificity

    DEFF Research Database (Denmark)

    Stokowy, Tomasz; Wojtas, Bartosz; Jarzab, Barbara

    2016-01-01

    Diagnosis of thyroid by fine needle aspiration is challenging for the "indeterminate" category and can be supported by molecular testing. We set out to identify miRNA markers that could be used in a diagnostic setting to improve the discrimination of mutation-negative indeterminate fine needle...... aspirations. miRNA high-throughput sequencing was performed for freshly frozen tissue samples of 19 RAS and PAX8/PPARG mutation-negative follicular thyroid carcinomas, and 23 RAS and PAX8/PPARG mutation-negative follicular adenomas. Differentially expressed miRNAs were validated by quantitative polymerase...... chain reaction in a set of 44 fine needle aspiration samples representing 24 follicular thyroid carcinomas and 20 follicular adenomas. Twenty-six miRNAs characterized by a significant differential expression between follicular thyroid carcinomas and follicular adenomas were identified. Nevertheless...

  17. Effects of Force Load, Muscle Fatigue, and Magnetic Stimulation on Surface Electromyography during Side Arm Lateral Raise Task: A Preliminary Study with Healthy Subjects.

    Science.gov (United States)

    Cao, Liu; Wang, Ying; Hao, Dongmei; Rong, Yao; Yang, Lin; Zhang, Song; Zheng, Dingchang

    2017-01-01

    The aim of this study was to quantitatively investigate the effects of force load, muscle fatigue, and extremely low-frequency (ELF) magnetic stimulation on surface electromyography (SEMG) signal features during side arm lateral raise task. SEMG signals were recorded from 18 healthy subjects on the anterior deltoid using a BIOSEMI ActiveTwo system during side lateral raise task (with the right arm 90 degrees away from the body) with three different loads on the forearm (0 kg, 1 kg, and 3 kg; their order was randomized between subjects). The arm maintained the loads until the subject felt exhausted. The first 10 s recording for each load was regarded as nonfatigue status and the last 10 s before the subject was exhausted was regarded as fatigue status. The subject was then given a five-minute resting between different loads. Two days later, the same experiment was repeated on every subject, and this time the ELF magnetic stimulation was applied to the subject's deltoid muscle during the five-minute rest period. Three commonly used SEMG features, root mean square (RMS), median frequency (MDF), and sample entropy (SampEn), were analyzed and compared between different loads, nonfatigue/fatigue status, and ELF stimulation and no stimulation. Variance analysis results showed that the effect of force load on RMS was significant ( p 0.05). In comparison with nonfatigue status, for all the different force loads with and without ELF stimulation, RMS was significantly larger at fatigue (all p < 0.001) and MDF and SampEn were significantly smaller (all p < 0.001).

  18. Effects of Force Load, Muscle Fatigue, and Magnetic Stimulation on Surface Electromyography during Side Arm Lateral Raise Task: A Preliminary Study with Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Liu Cao

    2017-01-01

    Full Text Available The aim of this study was to quantitatively investigate the effects of force load, muscle fatigue, and extremely low-frequency (ELF magnetic stimulation on surface electromyography (SEMG signal features during side arm lateral raise task. SEMG signals were recorded from 18 healthy subjects on the anterior deltoid using a BIOSEMI ActiveTwo system during side lateral raise task (with the right arm 90 degrees away from the body with three different loads on the forearm (0 kg, 1 kg, and 3 kg; their order was randomized between subjects. The arm maintained the loads until the subject felt exhausted. The first 10 s recording for each load was regarded as nonfatigue status and the last 10 s before the subject was exhausted was regarded as fatigue status. The subject was then given a five-minute resting between different loads. Two days later, the same experiment was repeated on every subject, and this time the ELF magnetic stimulation was applied to the subject’s deltoid muscle during the five-minute rest period. Three commonly used SEMG features, root mean square (RMS, median frequency (MDF, and sample entropy (SampEn, were analyzed and compared between different loads, nonfatigue/fatigue status, and ELF stimulation and no stimulation. Variance analysis results showed that the effect of force load on RMS was significant (p0.05. In comparison with nonfatigue status, for all the different force loads with and without ELF stimulation, RMS was significantly larger at fatigue (all p<0.001 and MDF and SampEn were significantly smaller (all p<0.001.

  19. Novel design of honeybee-inspired needles for percutaneous procedure.

    Science.gov (United States)

    Sahlabadi, Mohammad; Hutapea, Parsaoran

    2018-04-18

    The focus of this paper is to present new designs of innovative bioinspired needles to be used during percutaneous procedures. Insect stingers have been known to easily penetrate soft tissues. Bioinspired needles mimicking the barbs in a honeybee stinger were developed for a smaller insertion force, which can provide a less invasive procedure. Decreasing the insertion force will decrease the tissue deformation, which is essential for more accurate targeting. In this study, some design parameters, in particular, barb shape and geometry (i.e. front angle, back angle, and height) were defined, and their effects on the insertion force were investigated. Three-dimensional printing technology was used to manufacture bioinspired needles. A specially-designed insertion test setup using tissue mimicking polyvinyl chloride (PVC) gels was developed to measure the insertion and extraction forces. The barb design parameters were then experimentally modified through detailed experimental procedures to further reduce the insertion force. Different scales of the barbed needles were designed and used to explore the size-scale effect on the insertion force. To further investigate the efficacy of the proposed needle design in real surgeries, preliminary ex vivo insertion tests into bovine liver tissue were performed. Our results show that the insertion force of the needles in different scales decreased by 21-35% in PVC gel insertion tests, and by 46% in bovine liver tissue insertion tests.

  20. Needle stick injury in a radiology department: a decade analysis

    International Nuclear Information System (INIS)

    Sayani, R.; Rajani, A.

    2012-01-01

    Objectives: To determine the frequency of needle stick injury in health care workers of radiology department. Study type, settings and duration: Cross sectional, observational study conducted at the Radiology department of Aga Khan University hospital from January 2000 to May 2010. Subject and Methods: All self-reported needle stick injuries data of Health care workers of radiology department was recorded. The personnel involved (Radiologist, resident, radiographer, nurses etc), area of working and the causes of injury were identified including the procedural or post procedural details. Patient's status of hepatitis or blood borne infection was also noted. Data was recorded and analyzed in Excel worksheet. Results: A total of 55 health workers reported needle stick injuries at all sections of radiology departments with maximum number needle stick injuries at general radiography, fluoroscopy and IVP section. Radiographers and radiology residents received the maximum number of injuries. Major cause of injury was cannulation however, many injuries occurred during disposing or handling of bin. In majority of cases the patients were not infected with any known blood borne infections. Conclusions: Doctors and nurses get needle-stick injuries while carrying out clinical procedures, while, ancillary staff get infected post procedure during disposal of garbage. Policy message: Good occupational health and safety practices must be promoted to all staff. Safer disposal of needles is an important area where practice and procedure needs to be carefully reviewed. It is necessary to undertake a risk assessment, to offer counseling and Post Exposure Prophylaxis and treatment where necessary. (author)

  1. Dry needling in lateral epicondylitis: a prospective controlled study.

    Science.gov (United States)

    Uygur, Esat; Aktaş, Birol; Özkut, Afşar; Erinç, Samet; Yilmazoglu, Emime Gül

    2017-11-01

    Lateral epicondylitis (LE), a common disease, especially in middle age, causes decreased productivity and economic losses. The first-line treatment for LE is conservative and consists of topical and oral anti-inflammatory drugs, ice application, and brace use. If the first-line treatment fails, second-line treatment modalities, which are generally invasive, are offered. Second-line therapeutic regimens include saline, corticosteroid, or platelet-rich plasma injections. Dry needling is relatively new. We hypothesized that dry needling would be at least as effective as first-line treatment for LE. We compared the outcomes of first-line treatment and dry needling. The study allocated 110 patients into groups using online randomization software. After completing the Patient-rated Tennis Elbow Evaluation (PRTEE), patients in group I received dry needling, whereas those in group II received first-line treatment, consisting of ibuprofen 100 mg twice a day and a proximal forearm brace. The patients were evaluated after three weeks and six months. The study ultimately analyzed 92 patients. Although both treatment methods were effective at three weeks, dry needling was significantly more effective than the first-line treatment at six months. Because of the low complication rate, dry needling is a safe method, and it might be an effective treatment option for LE.

  2. Deep learning with convolutional neural networks: a resource for the control of robotic prosthetic hands via electromyography

    Directory of Open Access Journals (Sweden)

    Manfredo Atzori

    2016-09-01

    Full Text Available Motivation: Natural control methods based on surface electromyography and pattern recognition are promising for hand prosthetics. However, the control robustness offered by scientific research is still not sufficient for many real life applications and commercial prostheses are in the best case capable to offer natural control for only a few movements. Objective: In recent years deep learning revolutionized several fields of machine learning, including computer vision and speech recognition. Our objective is to test its capabilities for the natural control of robotic hands via surface electromyography by providing a baseline on a large number of intact and amputated subjects. Methods: We tested convolutional networks for the classification of an average of 50 hand movements in 67 intact subjects and 11 hand amputated subjects. The simple architecture of the neural network allowed to make several tests in order to evaluate the effect of pre-processing, layer architecture, data augmentation and optimization. The classification results are compared with a set of classical classification methods applied on the same datasets.Results: The classification accuracy obtained with convolutional neural networks using the proposed architecture is higher than the average results obtained with the classical classification methods but lower than the results obtained with the best reference methods in our tests. Significance: The results show that convolutional neural networks with a very simple architecture can produce accuracy comparable to the average classical classification methods. They show that several factors (including pre-processing, the architecture of the net and the optimization parameters can be fundamental for the analysis of surface electromyography data. Finally, the results suggest that deeper and more complex networks may increase dexterous control robustness, thus contributing to bridge the gap between the market and scientific research

  3. Effects of 2 ankle destabilization devices on electromyography measures during functional exercises in individuals with chronic ankle instability.

    Science.gov (United States)

    Donovan, Luke; Hart, Joseph M; Hertel, Jay

    2015-03-01

    Randomized crossover laboratory study. To determine the effects of ankle destabilization devices on surface electromyography (sEMG) measures of selected lower extremity muscles during functional exercises in participants with chronic ankle instability. Ankle destabilization devices are rehabilitation tools that can be worn as a boot or sandal to increase lower extremity muscle activation during walking in healthy individuals. However, they have not been tested in a population with pathology. Fifteen adults with chronic ankle instability participated. Surface electromyography electrodes were located over the anterior tibialis, fibularis longus, lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius. The activity level of these muscles was recorded in a single testing session during unipedal stance with eyes closed, the Star Excursion Balance Test, lateral hops, and treadmill walking. Each task was performed under 3 conditions: shod, ankle destabilization boot, and ankle destabilization sandal. Surface electromyography signal amplitudes were measured for each muscle during each exercise for all 3 conditions. Participants demonstrated a significant increase, with moderate to large effect sizes, in sEMG signal amplitude of the fibularis longus in the ankle destabilization boot and ankle destabilization sandal conditions during the unipedal eyes-closed balance test, the Star Excursion Balance Test in the anterior and posteromedial directions, lateral hops, and walking, when compared to the shod condition. Both devices also resulted in an increase in sEMG signal amplitudes, with large effect sizes of the lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius during the unipedal-stance-with-eyes-closed test, compared to the shod condition. Wearing ankle destabilization devices caused greater muscle activation during functional exercises in individuals with chronic ankle instability. Based on the magnitude of the effect, there were

  4. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  5. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  6. Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System

    Directory of Open Access Journals (Sweden)

    Scott K. Lynn, Casey M. Watkins, Megan A. Wong, Katherine Balfany, Daniel F. Feeney

    2018-06-01

    Full Text Available The Athos ® wearable system integrates surface electromyography (sEMG electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials. In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL, vastus medialis (VM, and biceps femoris (BF. All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7 comprised one set at each speed and percent MVC (50%, 75%, 100% combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system on the repetition amplitude metrics (95%, peak, or sum. Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7

  7. A Biomechanical Comparison of Proportional Electromyography Control to Biological Torque Control Using a Powered Hip Exoskeleton

    Directory of Open Access Journals (Sweden)

    Aaron J. Young

    2017-06-01

    Full Text Available BackgroundDespite a large increase in robotic exoskeleton research, there are few studies that have examined human performance with different control strategies on the same exoskeleton device. Direct comparison studies are needed to determine how users respond to different types of control. The purpose of this study was to compare user performance using a robotic hip exoskeleton with two different controllers: a controller that targeted a biological hip torque profile and a proportional myoelectric controller.MethodsWe tested both control approaches on 10 able-bodied subjects using a pneumatically powered hip exoskeleton. The state machine controller targeted a biological hip torque profile. The myoelectric controller used electromyography (EMG of lower limb muscles to produce a proportional control signal for the hip exoskeleton. Each subject performed two 30-min exoskeleton walking trials (1.0 m/s using each controller and a 10-min trial with the exoskeleton unpowered. During each trial, we measured subjects’ metabolic cost of walking, lower limb EMG profiles, and joint kinematics and kinetics (torques and powers using a force treadmill and motion capture.ResultsCompared to unassisted walking in the exoskeleton, myoelectric control significantly reduced metabolic cost by 13% (p = 0.005 and biological hip torque control reduced metabolic cost by 7% (p = 0.261. Subjects reduced muscle activity relative to the unpowered condition for a greater number of lower limb muscles using myoelectric control compared to the biological hip torque control. More subjects subjectively preferred the myoelectric controller to the biological hip torque control.ConclusionMyoelectric control had more advantages (metabolic cost and muscle activity reduction compared to a controller that targeted a biological torque profile for walking with a robotic hip exoskeleton. However, these results were obtained with a single exoskeleton device with specific

  8. A Biomechanical Comparison of Proportional Electromyography Control to Biological Torque Control Using a Powered Hip Exoskeleton.

    Science.gov (United States)

    Young, Aaron J; Gannon, Hannah; Ferris, Daniel P

    2017-01-01

    Despite a large increase in robotic exoskeleton research, there are few studies that have examined human performance with different control strategies on the same exoskeleton device. Direct comparison studies are needed to determine how users respond to different types of control. The purpose of this study was to compare user performance using a robotic hip exoskeleton with two different controllers: a controller that targeted a biological hip torque profile and a proportional myoelectric controller. We tested both control approaches on 10 able-bodied subjects using a pneumatically powered hip exoskeleton. The state machine controller targeted a biological hip torque profile. The myoelectric controller used electromyography (EMG) of lower limb muscles to produce a proportional control signal for the hip exoskeleton. Each subject performed two 30-min exoskeleton walking trials (1.0 m/s) using each controller and a 10-min trial with the exoskeleton unpowered. During each trial, we measured subjects' metabolic cost of walking, lower limb EMG profiles, and joint kinematics and kinetics (torques and powers) using a force treadmill and motion capture. Compared to unassisted walking in the exoskeleton, myoelectric control significantly reduced metabolic cost by 13% ( p  = 0.005) and biological hip torque control reduced metabolic cost by 7% ( p  = 0.261). Subjects reduced muscle activity relative to the unpowered condition for a greater number of lower limb muscles using myoelectric control compared to the biological hip torque control. More subjects subjectively preferred the myoelectric controller to the biological hip torque control. Myoelectric control had more advantages (metabolic cost and muscle activity reduction) compared to a controller that targeted a biological torque profile for walking with a robotic hip exoskeleton. However, these results were obtained with a single exoskeleton device with specific control configurations while level walking at a

  9. Electromyography-Guided Botulinum Toxin Injection Into the Cricothyroid Muscles in Bilateral Vocal Fold Abductor Paralysis.

    Science.gov (United States)

    Sahin, Mustafa; Aydogdu, Ibrahim; Akyildiz, Serdar; Erdinc, Munevver; Ozturk, Kerem; Ogut, Fatih

    2017-06-01

    Bilateral vocal fold abductor paralysis (BVFAP) both deteriorates quality of life and may cause life-threatening respiratory problems. The aim of this study was to reduce respiratory symptoms in BVFAP patients using cricothyroid (CT) botulinum toxin (BTX) injection. Before and 2 weeks and 4 months after bilateral BTX injection into the CT muscles under electromyography; alterations in respiratory, acoustic, aerodynamic and quality of life parameters were evaluated in BVFAP patients with respiratory distress. For the respiratory evaluation modified Borg scale and spirometry, for the voice and aerodynamic evaluations Voice Handicap Index-30 (VHI-30), GRBAS, acoustic analysis (sound pressure level, F0, jitter%, shimmer%, noise-to-harmonic ratio) and maximum phonation time and for the quality of life assessment Short Form-36 (SF-36) form were used. All patients were female with a mean age of 47±8.1 years. There was a mean time of 11.8±5.5 (minimum 2, maximum 23) months between BVFAP development and BTX injection. In all cases, other than one case with unknown aetiology, the cause of vocal fold paralysis was prior thyroid surgery. In total 18.6±3.1 units of BTX were applied to the CTs. In the preinjection period, and the 2nd week and 4th month after injection, the Borg dyspnea scale was 7.3/5.3/5.0, FIV1 (forced inspiratory volume in one second) was 1.7/1.7/1.8 L, peak expiratory flow (PEF) was 1.4/1.7/2.1 L/sec, maximum phonation time was 7.0/6.4/6.2 seconds and VHI-30 was 63.2/52.2/61.7 respectively. There was no significant alteration in acoustic analysis parameters. Many of the patients reported transient dysphagia within the first week. There were insignificant increases in SF-36 sub-scale values. After BTX injection, improvements in the mean Borg score, PEF and FIV1 values and SF-36 sub-scale scores showed the restricted success of this approach. This modality may be kept in mind as a transient treatment option for patients refused persistent tracheotomy or

  10. Patterns of variation across primates in jaw-muscle electromyography during mastication.

    Science.gov (United States)

    Vinyard, Christopher J; Wall, Christine E; Williams, Susan H; Hylander, William L

    2008-08-01

    Biologists that study mammals continue to discuss the evolution of and functional variation in jaw-muscle activity during chewing. A major barrier to addressing these issues is collecting sufficient in vivo data to adequately capture neuromuscular variation in a clade. We combine data on jaw-muscle electromyography (EMG) collected during mastication from 14 species of primates and one of treeshrews to assess patterns of neuromuscular variation in primates. All data were collected and analyzed using the same methods. We examine the variance components for EMG parameters using a nested ANOVA design across successive hierarchical factors from chewing cycle through species for eight locations in the masseter and temporalis muscles. Variation in jaw-muscle EMGs was not distributed equally across hierarchical levels. The timing of peak EMG activity showed the largest variance components among chewing cycles. Relative levels of recruitment of jaw muscles showed the largest variance components among chewing sequences and cycles. We attribute variation among chewing cycles to (1) changes in food properties throughout the chewing sequence, (2) variation in bite location, and (3) the multiple ways jaw muscles can produce submaximal bite forces. We hypothesize that variation among chewing sequences is primarily related to variation in properties of food. The significant proportion of variation in EMGs potentially linked to food properties suggests that experimental biologists must pay close attention to foods given to research subjects in laboratory-based studies of feeding. The jaw muscles exhibit markedly different variance components among species suggesting that primate jaw muscles have evolved as distinct functional units. The balancing-side deep masseter (BDM) exhibits the most variation among species. This observation supports previous hypotheses linking variation in the timing and activation of the BDM to symphyseal fusion in anthropoid primates and in strepsirrhines

  11. A Novel Feature Optimization for Wearable Human-Computer Interfaces Using Surface Electromyography Sensors

    Directory of Open Access Journals (Sweden)

    Han Sun

    2018-03-01

    Full Text Available The novel human-computer interface (HCI using bioelectrical signals as input is a valuable tool to improve the lives of people with disabilities. In this paper, surface electromyography (sEMG signals induced by four classes of wrist movements were acquired from four sites on the lower arm with our designed system. Forty-two features were extracted from the time, frequency and time-frequency domains. Optimal channels were determined from single-channel classification performance rank. The optimal-feature selection was according to a modified entropy criteria (EC and Fisher discrimination (FD criteria. The feature selection results were evaluated by four different classifiers, and compared with other conventional feature subsets. In online tests, the wearable system acquired real-time sEMG signals. The selected features and trained classifier model were used to control a telecar through four different paradigms in a designed environment with simple obstacles. Performance was evaluated based on travel time (TT and recognition rate (RR. The results of hardware evaluation verified the feasibility of our acquisition systems, and ensured signal quality. Single-channel analysis results indicated that the channel located on the extensor carpi ulnaris (ECU performed best with mean classification accuracy of 97.45% for all movement’s pairs. Channels placed on ECU and the extensor carpi radialis (ECR were selected according to the accuracy rank. Experimental results showed that the proposed FD method was better than other feature selection methods and single-type features. The combination of FD and random forest (RF performed best in offline analysis, with 96.77% multi-class RR. Online results illustrated that the state-machine paradigm with a 125 ms window had the highest maneuverability and was closest to real-life control. Subjects could accomplish online sessions by three sEMG-based paradigms, with average times of 46.02, 49.06 and 48.08 s

  12. Determining Changes in Electromyography Indices when Measuring Maximum Acceptable Weight of Lift in Iranian Male Students.

    Science.gov (United States)

    Salehi Sahl Abadi, A; Mazloumi, A; Nasl Saraji, G; Zeraati, H; Hadian, M R; Jafari, A H

    2018-03-01

    In spite of the increasing degree of automation in industry, manual material handling (MMH) is still performed in many occupational settings. The aim of the current study was to determine the maximum acceptable weight of lift using psychophysical and electromyography indices. This experimental study was conducted among 15 male students recruited from Tehran University of Medical Sciences. Each participant performed 18 different lifting tasks which involved three lifting frequencies, three lifting heights and two box sizes. Each set of experiments was conducted during the 20 min work period using free-style lifting technique and subjective as well as objective assessment methodologies. SPSS version 18 software was used for descriptive and analytical analyses by Friedman, Wilcoxon and Spearman correlation techniques. The results demonstrated that muscle activity increased with increasing frequency, height of lift and box size (P<0.05). Meanwhile, MAWLs obtained in this study are lower than those in Snook table (P<0.05). In this study, the level of muscle activity in percent MVC in relation to the erector spine muscles in L3 and T9 regions as well as left and right abdominal external oblique muscles were at 38.89%, 27.78%, 11.11% and 5.55% in terms of muscle activity is more than 70% MVC, respectively. The results of Wilcoxon test revealed that for both small and large boxes under all conditions, significant differences were detected between the beginning and end of the test values for MPF of erector spine in L3 and T9 regions, and left and right abdominal external oblique muscles (P<0.05). The results of Spearman correlation test showed that there was a significant relation between the MAWL, RMS and MPF of the muscles in all test conditions (P<0.05). Based on the results of this study, it was concluded if muscle activity is more than 70% of MVC, the values of Snook tables should be revisited. Furthermore, the biomechanical perspective should receive special attention

  13. Transcription through the eye of a needle: daily and annual cyclic gene expression variation in Douglas-fir needles

    OpenAIRE

    Cronn, Richard; Dolan, Peter C.; Jogdeo, Sanjuro; Wegrzyn, Jill L.; Neale, David B.; St. Clair, J. Bradley; Denver, Dee R.

    2017-01-01

    Background Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal cycles and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii) n...

  14. Transcription Through The Eye Of A Needle: Daily And Annual Cycles Of Gene Expression Variation In Douglas-Fir Needles

    OpenAIRE

    Dolan, Peter; Cronn, Richard; Denver, Dee; Clair, J.; Neale, David; Wegrzyn, Jill; Jogdeo, Sanjuro

    2017-01-01

    Background: Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal rhythms and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii)...

  15. Quantitative research.

    Science.gov (United States)

    Watson, Roger

    2015-04-01

    This article describes the basic tenets of quantitative research. The concepts of dependent and independent variables are addressed and the concept of measurement and its associated issues, such as error, reliability and validity, are explored. Experiments and surveys – the principal research designs in quantitative research – are described and key features explained. The importance of the double-blind randomised controlled trial is emphasised, alongside the importance of longitudinal surveys, as opposed to cross-sectional surveys. Essential features of data storage are covered, with an emphasis on safe, anonymous storage. Finally, the article explores the analysis of quantitative data, considering what may be analysed and the main uses of statistics in analysis.

  16. SURFACE ELECTROMYOGRAPHY OF MASSETER AND TEMPORAL MUSCLES WITH USE PERCENTAGE WHILE CHEWING ON CANDIDATES FOR GASTROPLASTY.

    Science.gov (United States)

    Santos, Andréa Cavalcante Dos; Silva, Carlos Antonio Bruno da

    Surface electromyography identifies changes in the electrical potential of the muscles during each contraction. The percentage of use is a way to treat values enabling comparison between groups. To analyze the electrical activity and the percentage of use of masseter and temporal muscles during chewing in candidates for gastric bypass. It was used Surface Electromyography Miotool 200,400 (Miotec (r), Porto Alegre/RS, Brazil) integrated with Miograph 2.0 software, involving patients between 20-40 years old. Were included data on electrical activity simultaneously and in pairs of temporal muscle groups and masseter at rest, maximum intercuspation and during the chewing of food previously classified. Were enrolled 39 patients (59 women), mean age 27.1+/-5.7. The percentage of use focused on temporal muscle, in a range of 11-20, female literacy (n=11; 47.82) on the left side and 15 (65.21) on the right-hand side. In the male, nine (56.25) at left and 12 (75.00) on the right-hand side. In masseter, also in the range of 11 to 20, female literacy (n=10; 43.48) on the left side and 11 (47.83) on the right-hand side. In the male, nine (56.25) at left and eight (50.00) on the right-hand side. 40-50% of the sample showed electrical activity in muscles (masseter and temporal) with variable values, and after processing into percentage value, facilitating the comparison of load of used electrical activity between the group, as well as usage percentage was obtained of muscle fibers 11-20% values involving, representing a range that is considered as a reference to the group studied. The gender was not a variable. A eletromiografia de superfície identifica variações dos potenciais elétricos dos músculos durante cada contração realizada. O percentual de uso é uma forma de tratar valores possibilitando comparação entre grupos. Analisar a atividade elétrica e o percentual de uso dos músculos masséteres e temporais durante a mastigação em candidatos à gastroplastia

  17. Intra-operative navigation of a 3-dimensional needle localization system for precision of irreversible electroporation needles in locally advanced pancreatic cancer.

    Science.gov (United States)

    Bond, L; Schulz, B; VanMeter, T; Martin, R C G

    2017-02-01

    Irreversible electroporation (IRE) uses multiple needles and a series of electrical pulses to create pores in cell membranes and cause cell apoptosis. One of the demands of IRE is the precise needle spacing required. Two-dimensional intraoperative ultrasound (2-D iUS) is currently used to measure inter-needle distances but requires significant expertise. This study evaluates the potential of three-dimensional (3-D) image guidance for placing IRE needles and calculating needle spacing. A prospective clinical evaluation of a 3-D needle localization system (Explorer™) was evaluated in consecutive patients from April 2012 through June 2013 for unresectable pancreatic adenocarcinoma. 3-D reconstructions of patients' anatomy were generated from preoperative CT images, which were aligned to the intraoperative space. Thirty consecutive patients with locally advanced pancreatic cancer were treated with IRE. The needle localization system setup added an average of 6.5 min to each procedure. The 3-D needle localization system increased surgeon confidence and ultimately reduced needle placement time. IRE treatment efficacy is highly dependent on accurate needle spacing. The needle localization system evaluated in this study aims to mitigate these issues by providing the surgeon with additional visualization and data in 3-D. The Explorer™ system provides valuable guidance information and inter-needle distance calculations. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  18. Quantitative habitability.

    Science.gov (United States)

    Shock, Everett L; Holland, Melanie E

    2007-12-01

    A framework is proposed for a quantitative approach to studying habitability. Considerations of environmental supply and organismal demand of energy lead to the conclusions that power units are most appropriate and that the units for habitability become watts per organism. Extreme and plush environments are revealed to be on a habitability continuum, and extreme environments can be quantified as those where power supply only barely exceeds demand. Strategies for laboratory and field experiments are outlined that would quantify power supplies, power demands, and habitability. An example involving a comparison of various metabolisms pursued by halophiles is shown to be well on the way to a quantitative habitability analysis.

  19. Students as effective harm reductionists and needle exchange organizers.

    Science.gov (United States)

    Barbour, Kyle; McQuade, Miriam; Brown, Brandon

    2017-03-17

    Needle exchange programs are safe, highly effective programs for promoting health among people who inject drugs. However, they remain poorly funded, and often illegal, in many places worldwide due to fear and stigma surrounding drug use. Continued advocacy, education, and implementation of new needle exchanges are thus essential to improve public health and reduce structural inequality. We argue that students, and especially professional and graduate students, have the potential to play an important role in advancing harm reduction. Students benefit from the respect given to the professions they are training to enter, which gives them leverage to navigate the political hurdles often faced by needle exchange organizers, especially in areas that presently lack services. In addition, due to their relative simplicity, needle exchanges do not require much of the licensing, clinical knowledge, and infrastructure associated with more traditional student programs, such as student-run free medical clinics. Students are capable of learning harm reduction cultural approaches and techniques if they remain humble, open-minded, and seek the help of the harm reduction community. Consequently, students can generate tremendous benefits to their community without performing beyond their appropriate clinical limitations. Students benefit from organizing needle exchanges by gaining applied experience in advocacy, organization-building, and political finesse. Working in a needle exchange significantly helps erode stigma against multiple marginalized populations. Students in health-related professions additionally learn clinically-relevant knowledge that is often lacking from their formal training, such as an understanding of structural violence and inequality, root causes of substance use, client-centered approaches to health services, and interacting with clients as peers, rather than through the standard hierarchical medical interaction. We therefore encourage students to learn about

  20. Needle Decompression of Tension Pneumothorax with Colorimetric Capnography.

    Science.gov (United States)

    Naik, Nimesh D; Hernandez, Matthew C; Anderson, Jeff R; Ross, Erika K; Zielinski, Martin D; Aho, Johnathon M

    2017-11-01

    The success of needle decompression for tension pneumothorax is variable, and there are no objective measures assessing effective decompression. Colorimetric capnography, which detects carbon dioxide present within the pleural space, may serve as a simple test to assess effective needle decompression. Three swine underwent traumatically induced tension pneumothorax (standard of care, n = 15; standard of care with needle capnography, n = 15). Needle thoracostomy was performed with an 8-cm angiocatheter. Similarly, decompression was performed with the addition of colorimetric capnography. Subjective operator assessment of decompression was recorded and compared with true decompression, using thoracoscopic visualization for both techniques. Areas under receiver operating curves were calculated and pairwise comparison was performed to assess statistical significance (P pneumothorax, that is, the absence of any pathologic/space-occupying lesion, in 100% of cases (10 of 10 attempts). Standard of care needle decompression was detected by operators in 9 of 15 attempts (60%) and was detected in 3 of 10 attempts when tension pneumothorax was not present (30%). True decompression, under direct visualization with thoracoscopy, occurred 15 of 15 times (100%) with capnography, and 12 of 15 times (80%) without capnography. Areas under receiver operating curves were 0.65 for standard of care and 1.0 for needle capnography (P = .002). Needle decompression with colorimetric capnography provides a rapid, effective, and highly accurate method for eliminating operator bias for tension pneumothorax decompression. This may be useful for the treatment of this life-threatening condition. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  1. Real-time and wearable functional electrical stimulation system for volitional hand motor function control using the electromyography bridge method

    Directory of Open Access Journals (Sweden)

    Hai-peng Wang

    2017-01-01

    Full Text Available Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy. A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method. Through a series of novel design concepts, including the integration of a detecting circuit and an analog-to-digital converter, a miniaturized functional electrical stimulation circuit technique, a low-power super-regeneration chip for wireless receiving, and two wearable armbands, a prototype system has been established with reduced size, power, and overall cost. Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects, the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy. Test results showed that wrist flexion/extension, hand grasp, and finger extension could be reproduced with high accuracy and low latency. This system can build a bridge of information transmission between healthy limbs and paralyzed limbs, effectively improve voluntary participation of hemiplegic patients, and elevate efficiency of rehabilitation training.

  2. Olfactory ensheathing glia transplantation combined with LASERPONCTURE in human spinal cord injury: Results measured by electromyography monitoring.

    Science.gov (United States)

    Bohbot, Albert

    2010-01-01

    Preliminary results were measured by electromyography monitoring (electromyoscan) on three subjects suffering from spinal cord injury and who underwent a double therapy. The aim of this study was to evaluate regained voluntary activity below the injury in subjects who received a double therapy: 1) an olfactory ensheathing glia (OEG) transplantation using procedures developed by Dr. Hongyun Huang at the Xishan Hospital and Rehabilitation Centre, Beijing, China, and 2) LASERPONCTURE developed by Albert Bohbot, Laboratoire de Recherches sur le LASERPONCTURE, La Chapelle Montlinard, France. Materials uses were the LASERPONCTURE device developed by Albert Bohbot; the PROCOMP5 equipment with softwares BIOGRAPH INFINITI 5 and REHAB SUITE; the sensors MYOSCAN-PRO EMG (SA9401M-50) to record muscle activity, and FLEX/PRO-SA9309M to record skin conductance were fixed on the skin. An infrared laser, whose frequencies and power settings cannot be disclosed due to its proprietary nature, was applied after an OEG injection performed according to Dr. Hongyun Huang's procedures. Three cases, two males and one female, were selected for this study. Presentation and comments of the graphs recordings of voluntary muscle activity below the injury are provided. This preliminary study suggests that the double therapy restores some voluntary muscle activity as measured by electromyography monitoring.

  3. The study of surface electromyography used for the assessment of abductor hallucis muscle activity in patients with hallux valgus.

    Science.gov (United States)

    Mortka, Kamila; Lisiński, Przemysław; Wiertel-Krawczuk, Agnieszka

    2018-01-26

    Hallux valgus is a common foot disorder. In patients with hallux valgus, the anatomy and biomechanics of foot is subject to alterations. The aim of this clinical and neurophysiological study is to compare the activity of abductor hallucis (AbdH) muscle between the group of patients with hallux valgus and control group of healthy people, with the use of surface electromyography. The study involved 44 feet with diagnosed hallux valgus (research group) and 42 feet without deformation (control group). The X-ray images, measurements of range of motion in the first metatarsophalangeal joint and in hallux interphalangeal joint, and the surface electromyography study recorded from AbdH muscle were performed. Considering the amplitude of motor unit action potential, study participants with hallux valgus demonstrate significantly less activity of AbdH muscle than people without hallux valgus deformity. This activity is not dependent on the severity of valgus, age, or range of motion. It is speculated that the changes of the AbdH function may occur in the period before clinical appearance of hallux valgus deformity, or at the onset of distortion development. Further studies are needed for a comprehensive assessment of AbdH muscle in patients with hallux valgus.

  4. Identification of first-stage labor arrest by electromyography in term nulliparous women after induction of labor.

    Science.gov (United States)

    Vasak, Blanka; Graatsma, Elisabeth M; Hekman-Drost, Elske; Eijkemans, Marinus J; Schagen van Leeuwen, Jules H; Visser, Gerard H A; Jacod, Benoit C

    2017-07-01

    Worldwide induction and cesarean delivery rates have increased rapidly, with consequences for subsequent pregnancies. The majority of intrapartum cesarean deliveries are performed for failure to progress, typically in nulliparous women at term. Current uterine registration techniques fail to identify inefficient contractions leading to first-stage labor arrest. An alternative technique, uterine electromyography has been shown to identify inefficient contractions leading to first-stage arrest of labor in nulliparous women with spontaneous onset of labor at term. The objective of this study was to determine whether this finding can be reproduced in induction of labor. Uterine activity was measured in 141 nulliparous women with singleton term pregnancies and a fetus in cephalic position during induced labor. Electrical activity of the myometrium during contractions was characterized by its power density spectrum. No significant differences were found in contraction characteristics between women with induced labor delivering vaginally with or without oxytocin and women with arrested labor with subsequent cesarean delivery. Uterine electromyography shows no correlation with progression of labor in induced labor, which is in contrast to spontaneous labor. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  6. [Special penetration needling for refractory peripheral facial paralysis].

    Science.gov (United States)

    Cao, Rongjuan; Qiu, Xiaohu; Xie, Xiaokun

    2018-03-12

    To observe the clinical effect difference between special penetration needling and conventional penetration needling for the refractory peripheral facial paralysis. A total of 97 patients with intractable facial paralysis were randomized into an observation group (49 cases and 2 dropping) and a control group (48 cases and 4 dropping). In the observation group, special penetration needling at an angle about 45° between the penetration needle and paralysis muscle bundle was used, Yangbai (GB 14) through Touwei (ST 8), Yangbai (GB 14) through Shangxing (GV 23), Sizhukong (TE 23) through Yuyao (EX-HN 4), Qianzhen (Extra) through Yingxiang (LI 20), mutual penetration between Yingxiang (LI 20) and Jiache (ST 6). Conventional penetration needling was applied in the control group, Yangbai (GB 14) through Yuyao (EX-HN 4), Cuanzhu (BL 2) through Yuyao (EX-HN 4), mutual penetration between Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) through Dicang (ST 4), Sibai (ST 2) through Yingxiang (LI 20). Three groups of electroacupuncture (discontinuous wave, 1 Hz) with tolerance were connected respectively in the two groups, Yangbai (GB 14) and Sizhukong (TE 23), Yangbai (GB 14) and Qianzheng (Extra), Yingxiang (LI 20) and Jiache (ST 6) in the observation group, Yangbai (GB 14) and Cuanzhu (BL 2), Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) and Sibai (ST 2) in the control group. TDP was applied in the two groups at the affected Yifeng (TE 17), Jiache (ST 6) and Qianzheng (Extra), which were around the ear. Perpendicular insertion was used at Yifeng (TE 17) at the affected side and Hegu (LI 4) at the healthy side and bilateral Zusanli (ST 36). The needles were retained for 30 min. The treatment was given for 3 courses, once a day and 10 days as a course, 5 days at the interval. House-Brackmann (H-B) facial nerve grading score was recorded before and after treatment. The clinical effects were compared. The H-B scores after treatment in the two groups were higher than

  7. The Hydrodynamics of Needle-Free Intradermal Jet Injection

    Science.gov (United States)

    Simmons, Jonathan; Marston, Jeremy; Fisher, Paul; Broderick, Kate

    2017-11-01

    Needle-free methods of drug delivery circumvent the drawbacks associated with the use of hypodermic needles such as needle-stick injuries, needle-phobia, cross contamination and disposal. Furthermore, pioneering DNA-based vaccines that aim to treat cancer and fight infectious diseases, such as HIV, Ebola and Zika, require precise deposition into the skin to target the immune response producing cells found only in the epidermis and dermis. Intradermal (ID) delivery can be achieved using a needle and the Mantoux technique but this requires a highly skilled technician and so extensive use of DNA vaccines calls for an alternative method of delivery. One option is jet injection which has been employed in mass vaccination programs for intramuscular or subcutaneous delivery and is used by some diabetic patients to inject insulin. In this talk I will present results from our ongoing ex-vivo experimental study into ID jet injection. Ultra-high-speed imaging is used to visualize the process of the jet exiting the nozzle and striking excised skin. A skin bleb grows as liquid is deposited within the skin. I will discuss how the control parameters, such as the rheological profile of the liquid and the stand-off distance, influence the volume of liquid successfully delivered intradermally.

  8. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  9. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  10. MAINTENANCE PLANNING OF THE SEWING NEEDLES OF SIMPLE SEWING MACHINES

    Directory of Open Access Journals (Sweden)

    ŞUTEU Marius Darius

    2017-05-01

    Full Text Available The effectiveness of simple sewing machines can be increased through the planning of predictive maintenance activities. The monitoring of the technical condition of the sewing needles of simple sewing machines was based on the measurement of their noise level. For this purpose a Center 322 sonometer was used, while the data obtained during the monitoring process was analyzed through the E322 software. The working speed of the simple sewing machine that was used for obtaining the experimental results varied from 200 stitches/minute to 4000 stitches/minute. The noise levels of a new needle at the working speed of 200 stitches/minute and 4000 stitches/minute were measured. The noise levels for a fault needle at the same working speed of 200 stitches/minute, respectively 4000 stitches/minute were also measured. Using Fuzzy Logic Toolbox ™ module of Matlab®, a decision-making system for determining when replacement of the sewing needles of simple sewing machines should be performed was developed. A case study illustrates the employment of the decision-making system based on fuzzy logic for a simple sewing machine. By replacing the sewing needles of simple sewing machines at the time specified through the decision-making system based on fuzzy logic, the occurrence of the failure can be prevented and the quality of textile products can be improved.

  11. A microfluidic needle for sampling and delivery of chemical signals by segmented flows

    Science.gov (United States)

    Feng, Shilun; Liu, Guozhen; Jiang, Lianmei; Zhu, Yonggang; Goldys, Ewa M.; Inglis, David W.

    2017-10-01

    We have developed a microfluidic needle-like device that can extract and deliver nanoliter samples. The device consists of a T-junction to form segmented flows, parallel channels to and from the needle tip, and seven hydrophilic capillaries at the tip that form a phase-extraction region. The main microchannel is hydrophobic and carries segmented flows of water-in-oil. The hydrophilic capillaries transport the aqueous phase with a nearly zero pressure gradient but require a pressure gradient of 19 kPa for mineral oil to invade and flow through. Using this device, we demonstrate the delivery of nanoliter droplets and demonstrate sampling through the formation of droplets at the tip of our device. During sampling, we recorded the fluorescence intensities of the droplets formed at the tip while varying the concentration of dye outside the tip. We measured a chemical signal response time of approximately 3 s. The linear relationship between the recorded fluorescence intensity of samples and the external dye concentration (10-40 μg/ml) indicates that this device is capable of performing quantitative, real-time measurements of rapidly varying chemical signals.

  12. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtürk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean

    2012-01-01

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, δ. The candidate needle set consisted of 5000 needles, and a range of δ values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of δ values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer

  13. Expermental Studies of quantitative evaluation using HPLC

    Directory of Open Access Journals (Sweden)

    Ki Rok Kwon

    2005-06-01

    Full Text Available Methods : This study was conducted to carry out quantitative evaluation using HPLC Content analysis was done using HPLC Results : According to HPLC analysis, each BVA-1 contained approximately 0.36㎍ melittin, and BVA-2 contained approximately 0.54㎍ melittin. But the volume of coating was so minute, slight difference exists between each needle. Conclusion : Above results indicate that the bee venom acupuncture can complement shortcomings of syringe usage as a part of Oriental medicine treatment, but extensive researches should be done for further verification.

  14. Quantitative Finance

    Science.gov (United States)

    James, Jessica

    2017-01-01

    Quantitative finance is a field that has risen to prominence over the last few decades. It encompasses the complex models and calculations that value financial contracts, particularly those which reference events in the future, and apply probabilities to these events. While adding greatly to the flexibility of the market available to corporations and investors, it has also been blamed for worsening the impact of financial crises. But what exactly does quantitative finance encompass, and where did these ideas and models originate? We show that the mathematics behind finance and behind games of chance have tracked each other closely over the centuries and that many well-known physicists and mathematicians have contributed to the field.

  15. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  16. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  17. Understanding the physiology of postharvest needle abscission in balsam fir

    Directory of Open Access Journals (Sweden)

    Mason Thane Macdonald

    2015-11-01

    Full Text Available Balsam fir (Abies balsamea trees are commonly used as a specialty horticultural species for Christmas trees and associated greenery in eastern Canada and United States. Postharvest needle abscission has always been a problem, but is becoming an even bigger challenge in recent years presumably due to increased autumn temperatures and earlier harvesting practices. An increased understanding of postharvest abscission physiology in balsam fir may benefit the Christmas tree industry while simultaneously advancing our knowledge in senescence and abscission of conifers in general. Our paper describes the dynamics of needle abscission in balsam fir while identifying key factors that modify abscission patterns. Concepts such as genotypic abscission resistance, nutrition, environmental factors, and postharvest changes in water conductance and hormone evolution are discussed as they relate to our understanding of the balsam fir abscission physiology. Our paper ultimately proposes a pathway for needle abscission via ethylene and also suggests other potential alternative pathways based on our current understanding.

  18. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  19. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  20. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.

    Science.gov (United States)

    Limmer, Alexandra M; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  1. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    Directory of Open Access Journals (Sweden)

    Alexandra M. Limmer

    2017-01-01

    Full Text Available Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient’s caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  2. Spruce needles used as radioecological biotracers; Fichtennadeln als radiooekologische Bioindikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, C.; Gruber, V.; Baumgartner, A. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; Idinger, J. [Technische Univ. Wien (Austria). Atominst.; Fuerst, A. [BFW - Bundesforschungs- und Ausbildungszentrum fuer Wald, Naturgefahren und Landschaft, Wien (Austria). Inst. fuer Waldschutz, Pflanzenanalyse; Maringer, F.J. [BOKU - Univ. fuer Bodenkultur Wien (Austria). LLC-Labor Arsenal; BEV - Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    2009-07-01

    In a two years project spruce needle samples of the Austrian Bioindicator Grid were analysed by gamma-ray spectrometry to investigate the spatial and temporal distribution of radionuclides in spruce needles of the last 25 years with the main focus on the radioactive contamination before and after the Chernobyl fallout 1986. More than 600 spruce needle samples at selected locations of the Bioindicator Grid were analysed for different natural and anthropogenic radionuclides: {sup 137}Cs, {sup 40}K, {sup 210}Pb, {sup 226}Ra, {sup 228}Ra, {sup 238}U. Additionally, soil samples were taken at selected sites to study the soil-to-plant transfer. This radioecological evaluation is an important part of an existing environmental surveillance programme in Upper Austria in order to gain basic information on the impact of environmental changes on the radioecological behaviour of spruce trees. (orig.)

  3. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  4. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  5. SU-D-213AB-06: Surface Texture and Insertion Speed Effect on Needle Friction.

    Science.gov (United States)

    Abdullah, A; Golecki, C; Barnett, A; Moore, J

    2012-06-01

    High frictional forces between the needle surface and tissue cause tissue deflection which hinders accurate needle placement for procedures such as brachytherapy and needle biopsy. Accurate needle placement isimportant to maximize procedure efficacy. This work investigates how needle surface roughness and insertion speed affect the frictional forcebetween a needle and tissue. A friction experiment was conducted to measure the force of friction between bovine liver and three 11 gauge needles having Ra surface roughness of 3.43, 1.33, and 0.2 μm. Each of the three needles were mounted on a linear slide and were advanced and retracted through bovine liver at speeds of 50, 100, 150, and 200 mm/s for a total of 12 trials. In each trial the needle was advanced and retracted in 10 cycles producing a steady state insertion force and a steady state retraction force for each cycle. A force sensor connecting the needle to the linear slide recorded the resistance force of the needle sliding through the liver. The liver was mounted in a box with a pneumatic cylinder which compressed the liver sample by 11.65 kPa. The roughest needle (Ra = 3.43 μm) on average produced 68, 73, 74, and 73% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200mm/s, respectively. The second roughest needle (Ra = 1.33 μm) on average produced 25, 45, 60 and 64% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200 mm/s, respectively. Rougher needle surface texture and higher insertion speed reduced frictional forces between the tissue and the needle. Future studies will examine how frictional forces can be modeled and predicted given surface texture and insertion speed. © 2012 American Association of Physicists in Medicine.

  6. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  7. Laparoscopic removal of a needle from the pancreas

    Directory of Open Access Journals (Sweden)

    Amit Jain

    2013-01-01

    Full Text Available Foreign bodies inside the pancreas are rare and usually occur after the ingestion of sharp objects like fish bone, sewing needle and toothpick. Most of the ingested foreign bodies pass spontaneously through the anus without being noticed but about 1% of them can perforate through the wall of stomach or duodenum to reach solid organs like pancreas or liver. Once inside the pancreas they can produce complications like abscess, pseudoaneurysm or pancreatits. Foreign bodies of pancreas should be removed by endoscopic or surgical methods. We hereby report our experience of successful removal one a sewing needle from pancreas.

  8. The Gothic arch (needle point) tracing and condylar inclination.

    Science.gov (United States)

    el-Gheriani, A S; Winstanley, R B

    1987-11-01

    The records of 11 patients referred for treatment of TMJ disorders were used to compare condylar inclination found by drawing a tangent and by using a mathematic technique. Needle point tracing angles were also measured for the same patients and were compared with the condylar inclination. It can be concluded that (1) the mathematic technique outlined records a more accurate condylar angulation, and (2) there is a great variation in condylar inclination values between patients and between left and right sides of the same patient, and (3) there is no direct relationship between condylar inclination and the needle point tracing angle.

  9. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  10. Endoscopic vocal fold injection using a 25-gauge butterfly needle.

    Science.gov (United States)

    Buchanan, M A; Riffat, F; Palme, C E

    2016-04-01

    To describe a useful technique for infiltrating a bulking agent using a butterfly needle, as part of a transoral endoscopic vocal fold medialisation procedure. This paper describes the procedure of grasping the needle with phonosurgery forceps and administering the injectate to the vocal fold through careful application of the syringe plunger via a length of rubber tubing from outside the mouth. This procedure is performed routinely in our institution without complication. The advantages of this technique are discussed. This is a safe and easy method of injecting into a vocal fold.

  11. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  12. Determination of rare earth elements in the biological reference materials Pine Needles and Spruce Needles by neutron activation analysis

    International Nuclear Information System (INIS)

    Machado, C.N.; Maria, S.P.; Saiki, M.; Figueiredo, A.M.G.

    1998-01-01

    Instrumental neutron activation analysis was applied to determine La, Ce, Nd, Sm, Eu, Tb, Yb, Lu and Sc in two biological reference materials: NIST 1575 Pine Needles and BCR-CRM 101 Spruce Needles. The purpose was to contribute to the reference data for these two reference materials. The results were obtained with a good precision (relative standard deviations less than 15%). For the Pine Needles reference material there are already some proposed values and our results showed, in general, a good agreement with the data published. The contribution of uranium fission products to La, Ce, Nd and Sm was evaluated and considered in the determination of these elements. Interferences in the determination of rare earth elements in biological materials are also discussed. (author)

  13. Forest decline: Verification of phytohormones and secondary plant constituents (especially flavonoids and sesquiterpenes) in healthy and damaged needles from a natural site (Wank) with a defined pollutant load and defined infectious diseases (continuation). Final report. Waldschaeden: Nachweis von Phytohormonen und sekundaeren Pflanzenstoffen (vor allem Flavonoiden und Sesquiterpenen) in gesunden und geschaedigten Nadeln vom natuerlichen Standort (Wank), bei definierter Schadstoffbelastung und definierten Infektionskrankheiten (Fortsetzung). Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, H; Kraus, M; Deigele, C

    1992-03-01

    The aim of the project was to study the formation and accumulation of the phytohormone abscisic acid and soluble phenolic compounds and terpenes in spruce and fir needles with a view to various parameters (season, needle age, degree of damage, distribution within the tree crown, and site altitude), in the Wank forest under field conditions. For the extraction and clean-up of abscisic acid (ABA) a method by Doerffling was modified, and for its quantitative analysis ELISA, HPLC, GC with flame ionization and GC with electron capturing detector were tested and the latter chosen. In individual trees needles from the crown top had increased ABA content; needle age and degree of damage had no significant effect; the year curve showed a maximum in May/June and a minimum in August/September. As regards some soluble phenolic compounds, young needles, unlike older ones, have a year curve; the concentrations of some SPCs increase with altitude above mean sea level (ultraviolet radiation protection function, ozone effect possible but not confirmed), while the concentrations of some monoterpenes go down. Young needles (of cloned spruces) have no day curve for monoterpenes, but their concentration increases where water is scarce. The degree of damage (chlorotic needles, loss of needles) and SPC, monoterpene and sesquiterpene levels are not associated. (orig.)

  14. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    International Nuclear Information System (INIS)

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  15. Needles and Other Sharps (Safe Disposal Outside of Health Care Settings)

    Science.gov (United States)

    ... disorders, and psoriasis. Examples of sharps include: Needles – hollow needles used to inject drugs (medication) under the ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  16. Voluntary low-force contraction elicits prolonged low-frequency fatigue and changes in surface electromyography and mechanomyography

    DEFF Research Database (Denmark)

    Blangsted, Anne Katrine; Sjøgaard, Gisela; Madeleine, Pascal

    2005-01-01

    Controversies exist regarding objective documentation of fatigue development with low-force contractions. We hypothesized that non-exhaustive, low-force muscle contraction may induce prolonged low-frequency fatigue (LFF) that in the subsequent recovery period is detectable by electromyography (EMG......) and in particular mechanomyography (MMG) during low-force rather than high-force test contractions. Seven subjects performed static wrist extension at 10% maximal voluntary contraction (MVC) for 10 min (10%MVC10 min). Wrist force response to electrical stimulation of extensor carpi radialis muscle (ECR) quantified...... LFF. EMG and MMG were recorded from ECR during static test contractions at 5% and 80% MVC. Electrical stimulation, MVC, and test contractions were performed before 10%MVC10 min and at 10, 30, 90 and 150 min recovery. In spite of no changes in MVC, LFF persisted up to 150 min recovery but did...

  17. Surface electromyography activity of the rectus abdominis, internal oblique, and external oblique muscles during forced expiration in healthy adults.

    Science.gov (United States)

    Ito, Kenichi; Nonaka, Koji; Ogaya, Shinya; Ogi, Atsushi; Matsunaka, Chiaki; Horie, Jun

    2016-06-01

    We aimed to characterize rectus abdominis, internal oblique, and external oblique muscle activity in healthy adults under expiratory resistance using surface electromyography. We randomly assigned 42 healthy adult subjects to 3 groups: 30%, 20%, and 10% maximal expiratory intraoral pressure (PEmax). After measuring 100% PEmax and muscle activity during 100% PEmax, the activity and maximum voluntary contraction of each muscle during the assigned experimental condition were measured. At 100% PEmax, the external oblique (pinternal oblique (pexternal oblique (pinternal oblique (pexternal oblique: pinternal oblique: p<0.01). The abdominal oblique muscles are the most active during forced expiration. Moreover, 30% PEmax is the minimum intensity required to achieve significant, albeit very slight, muscle activity during expiratory resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The Effect of Local Anesthetic Volume Within the Adductor Canal on Quadriceps Femoris Function Evaluated by Electromyography

    DEFF Research Database (Denmark)

    Grevstad, Ulrik; Jæger, Pia; Kløvgaard, Johan

    2016-01-01

    BACKGROUND: Single-injection adductor canal block (ACB) provides analgesia after knee surgery. Which nerves that are blocked by an ACB and what influence-if any-local anesthetic volume has on the effects remain undetermined. We hypothesized that effects on the nerve to the vastus medialis muscle......, they received a femoral nerve block and a placebo ACB. The effect on the vastus medialis (primary endpoint) and the vastus lateralis was evaluated using noninvasive electromyography (EMG). Quadriceps femoris muscle strength was evaluated using a dynamometer. RESULTS: There was a statistically significant......L was used (P = 0.0001). No statistically significant differences were found between volume and effect on the vastus lateralis (P = 0.81) or in muscle strength (P = 0.15). CONCLUSIONS: For ACB, there is a positive correlation between local anesthetic volume and effect on the vastus medialis muscle. Despite...

  19. Ultrasonography for the diagnosis of tendinitis and electromyography for the diagnosis of peripheral neuropathy and upper limb radiculopathy: rheumatologists' perspectives.

    Science.gov (United States)

    Helfenstein, Milton; Ferreira, Mario Soares; Maia, Anna Beatriz Assad; Siena, César Augusto Fávaro; Techy, Antonio

    2013-01-01

    To ascertain the value ascribed by Brazilian rheumatologists to ultrasonography (US) for diagnosing tendinitis and to electromyography (EMG) for diagnosing peripheral neuropathy and upper limb radiculopathy. In total, 165 rheumatologists answered an anonymous survey (sent via the internet) concerning the two exams, with respect to the following characteristics: reliability, diagnostic accuracy, the importance and necessity of these tests for diagnostic The study revealed that most of the rheumatologists recognised that these exams are operator-dependent, that clinicians do not rely entirely on the results, that these exams are not mandatory for the diagnoses listed, and that professionals who perform these exams should be better trained to provide reliable results. The Brazilian rheumatologists believe the following: the results of these exams should be interpreted with caution and are not definitive for diagnosis; musculoskeletal US and EMG should be performed by trained professionals; and there must be better preparation of the professionals who perform these exams.

  20. Analysis of progression of fatigue conditions in biceps brachii muscles using surface electromyography signals and complexity based features.

    Science.gov (United States)

    Karthick, P A; Makaram, Navaneethakrishna; Ramakrishnan, S

    2014-01-01

    Muscle fatigue is a neuromuscular condition where muscle performance decreases due to sustained or intense contraction. It is experienced by both normal and abnormal subjects. In this work, an attempt has been made to analyze the progression of muscle fatigue in biceps brachii muscles using surface electromyography (sEMG) signals. The sEMG signals are recorded from fifty healthy volunteers during dynamic contractions under well defined protocol. The acquired signals are preprocessed and segmented in to six equal parts for further analysis. The features, such as activity, mobility, complexity, sample entropy and spectral entropy are extracted from all six zones. The results are found showing that the extracted features except complexity feature have significant variations in differentiating non-fatigue and fatigue zone respectively. Thus, it appears that, these features are useful in automated analysis of various neuromuscular activities in normal and pathological conditions.

  1. Non-invasive transabdominal uterine electromyography correlates with the strength of intrauterine pressure and is predictive of labor and delivery.

    Science.gov (United States)

    Maul, H; Maner, W L; Olson, G; Saade, G R; Garfield, R E

    2004-05-01

    The study was conducted to investigate whether the strength of uterine contractions monitored invasively by intrauterine pressure catheter could be determined from transabdominal electromyography (EMG) and to estimate whether EMG is a better predictor of true labor compared to tocodynamometry (TOCO). Uterine EMG was recorded from the abdominal surface in laboring patients simultaneously monitored with an intrauterine pressure catheter (n = 13) or TOCO (n = 24). Three to five contractions per patient and corresponding electrical bursts were randomly selected and analyzed (integral of intrauterine pressure; integral, frequency, amplitude of contraction curve on TOCO; burst energy for EMG). The Mann-Whitney test, Spearman correlation and receiver operator characteristics (ROC) analysis were used as appropriate (significance was assumed at a value of p TOCO parameters were different. In addition, burst energy levels were highly predictive of delivery within 48 h (AUC = 0.9531; p TOCO, transabdominal uterine EMG can be used reliably to predict labor and delivery.

  2. Effects of Hydrotherapy on postural control and electromyography parameters in men with chronic non-specific low back pain

    Directory of Open Access Journals (Sweden)

    Mahdi Mahjur

    2016-05-01

    Full Text Available The aim of this study was to evaluate effects of hydrotherapy on postural control and electromyography parameters in men with chronic non-specific low back pain. Thirty men with chronic non-specific LBP divided into two hydrotherapy and control groups, randomly and equally. Electromyographic activity of erector spinae muscles and balance measured for both of groups before and after intervention. Hydrotherapy program was consisted of 24 sessions. Subjects in control group didn’t have any special activity. Two-way variance was used to interpret the data and correlated and independent T-tests were used for analysis of data at the significance level of (P0.05. However, a significant difference observed between two groups in balance index (P<0.05.

  3. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    International Nuclear Information System (INIS)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto

    1996-01-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  4. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1996-09-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  5. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  6. Sensorimotor Learning of Acupuncture Needle Manipulation Using Visual Feedback.

    Directory of Open Access Journals (Sweden)

    Won-Mo Jung

    Full Text Available Humans can acquire a wide variety of motor skills using sensory feedback pertaining to discrepancies between intended and actual movements. Acupuncture needle manipulation involves sophisticated hand movements and represents a fundamental skill for acupuncturists. We investigated whether untrained students could improve their motor performance during acupuncture needle manipulation using visual feedback (VF.Twenty-one untrained medical students were included, randomly divided into concurrent (n = 10 and post-trial (n = 11 VF groups. Both groups were trained in simple lift/thrusting techniques during session 1, and in complicated lift/thrusting techniques in session 2 (eight training trials per session. We compared the motion patterns and error magnitudes of pre- and post-training tests.During motion pattern analysis, both the concurrent and post-trial VF groups exhibited greater improvements in motion patterns during the complicated lifting/thrusting session. In the magnitude error analysis, both groups also exhibited reduced error magnitudes during the simple lifting/thrusting session. For the training period, the concurrent VF group exhibited reduced error magnitudes across all training trials, whereas the post-trial VF group was characterized by greater error magnitudes during initial trials, which gradually reduced during later trials.Our findings suggest that novices can improve the sophisticated hand movements required for acupuncture needle manipulation using sensorimotor learning with VF. Use of two types of VF can be beneficial for untrained students in terms of learning how to manipulate acupuncture needles, using either automatic or cognitive processes.

  7. Hepatitis B Vaccination Status and Needle stick Injuries among ...

    African Journals Online (AJOL)

    Background: Hepatits B virus (HBV) is the most common blood borne pathogen that poses an occupational risk to Health-care workers. The incidence of infection following needle stick injury has been reported to be high among medical students. Effective vaccines against HBV are available. The aim of this study was to ...

  8. Seasonal recovery of chlorotic needles in Scotch pine

    Science.gov (United States)

    Jerry K. Jones; Jerry K. Jones

    1971-01-01

    As part of a research project on Christmas trees being carried on by the USDA Forest Service's Northeastern Forest Experiment Station, the author made a cooperative study of how discolored needles recover their normal color in February and April. Though this does not solve the Christmas tree growers' problem, it does shed some light on the process involved in...

  9. Mechanics of anesthetic needle penetration into human sciatic nerve.

    Science.gov (United States)

    Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A

    2018-06-06

    Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Percutaneous core needle biopsies: The yield in spinal tuberculosis

    African Journals Online (AJOL)

    2014-01-29

    Jan 29, 2014 ... abscess formation, which was epidural in 8 and prevertebral in 13. One patient ... To (i) assess the yield of percutaneous needle biopsies; (ii) identify factors that may lead to a negative result; and (iii) determine .... ultimately detected, not testing for drug susceptibility risks a delay of .... Int J Tuberc Lung Dis.

  11. A LARGE FOREIGN BODY IN THE TRACHEA (SEWING NEEDLE

    Directory of Open Access Journals (Sweden)

    P. D. Pryanikov

    2017-01-01

    Full Text Available The authors present a case study: an unusual foreign body (sewing needle in the trachea. Despite the large size and unusual shape of a foreign body, we managed to remove it through the airways with rigid upper traheobronchoscopy, avoiding complications.

  12. The Single Needle Lockstitch Machine. [Setting a Collar.] Module 5.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on sewing collars, one in a series on the single needle lockstitch sewing machine for student self-study, contains three sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  13. The Single Needle Lockstitch Machine. [Setting Zippers.] Module 8.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on setting zippers, one in a series on the single needle lockstitch sewing machine for student self-study, contains five sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  14. The Single Needle Lockstitch Machine. [Sewing Seams.] Module 4.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on sewing seams, one in a series on the single needle lockstitch sewing machine for student self-study, contains three sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final checklist.…

  15. The Single Needle Lockstitch Machine. [Constructing Darts.] Module 3.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on constructing darts, one in a series on the single needle lockstitch sewing machine for student self-study, contains two sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  16. Multi hollow needle to plate plasmachemical reactor for pollutant decomposition

    International Nuclear Information System (INIS)

    Pekarek, S.; Kriha, V.; Viden, I.; Pospisil, M.

    2001-01-01

    Modification of the classical multipin to plate plasmachemical reactor for pollutant decomposition is proposed in this paper. In this modified reactor a mixture of air and pollutant flows through the needles, contrary to the classical reactor where a mixture of air and pollutant flows around the pins or through the channel plus through the hollow needles. We give the results of comparison of toluene decomposition efficiency for (a) a reactor with the main stream of a mixture through the channel around the needles and a small flow rate through the needles and (b) a modified reactor. It was found that for similar flow rates and similar energy deposition, the decomposition efficiency of toluene was increased more than six times in the modified reactor. This new modified reactor was also experimentally tested for the decomposition of volatile hydrocarbons from gasoline distillation range. An average efficiency of VOC decomposition of about 25% was reached. However, significant differences in the decomposition of various hydrocarbon types were observed. The best results were obtained for the decomposition of olefins (reaching 90%) and methyl-tert-butyl ether (about 50%). Moreover, the number of carbon atoms in the molecule affects the quality of VOC decomposition. (author)

  17. Removing Phosphorus from Aqueous Solutions Using Lanthanum Modified Pine Needles.

    Directory of Open Access Journals (Sweden)

    Xianze Wang

    Full Text Available The renewable pine needles was used as an adsorbent to remove phosphorus from aqueous solutions. Using batch experiments, pine needles pretreated with alkali-isopropanol (AI failed to effectively remove phosphorus, while pine needles modified with lanthanum hydroxide (LH showed relatively high removal efficiency. LH pine needles were effective at a wide pH ranges, with the highest removal efficiency reaching approximately 85% at a pH of 3. The removal efficiency was kept above 65% using 10 mg/L phosphorus solutions at desired pH values. There was no apparent significant competitive behavior between co-existing anions of sulfate, nitrate, and chloride (SO4(2-, NO3(- and Cl(-; however, CO3(2- exhibited increased interfering behavior as concentrations increased. An intraparticle diffusion model showed that the adsorption process occurred in three phases, suggesting that a boundary layer adsorption phenomena slightly affected the adsorption process, and that intraparticle diffusion was dominant. The adsorption process was thermodynamically unfavorable and non-spontaneous; temperature increases improved phosphorus removal. Total organic carbon (TOC assays indicated that chemical modification reduced the release of soluble organic compounds from 135.6 mg/L to 7.76 mg/L. This new information about adsorption performances provides valuable information, and can inform future technological applications designed to remove phosphorus from aqueous solutions.

  18. Steering of flexible needles combining kinesthetic and vibratory force feedback

    NARCIS (Netherlands)

    Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure which demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and acceptance by

  19. Aerial surveys for Swiss needle cast in Western Oregon.

    Science.gov (United States)

    A. Kanaskie; M. McWilliams; J. Prukop; D. Overhulser; K. Sprengel

    2002-01-01

    In the last decade, Swiss needle cast (SNC), caused by the native fungus Phaeocryptopus gaeumannii, has severely damaged Douglas-fir in the Coast Range of western Oregon. The primary impact of the pathogen on Douglas-fir (the only susceptible tree species) is premature loss of foliage, which results in significant reduction in tree growth. Recent...

  20. Thyroid fine-needle aspiration and the bethesda classification system

    DEFF Research Database (Denmark)

    Larsen, Louise Vølund; Egset, Alice Viktoria; Holm, Camilla

    2018-01-01

    INTRODUCTION: Fine-needle aspiration (FNA) is a cornerstone in diagnosing thyroid nodules. For decades, Danish FNA have been categorised into the groups: “FNA not per-formed”, “Inadequate”, “Cystic”, “Inconclusive”, “Benign”, “Suspicious”, “Malignant” and “Information missing”. Internationally...

  1. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  2. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  3. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    Background: The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound‑guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those ...

  4. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    Objective: To estimate the sensitivity and specificity of FNAC in detecting malignancy for thyroid disease using histopathology ... thyroid carcinoma being the most predominant type and colloid goiter was the most predominant benign thyroid disease. The sensitivity ..... tic accuracy of fine needle aspiration cytology in thyroid.

  5. Single-incision laparoscopic cholecystectomy with needle graspers.

    Science.gov (United States)

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  6. Pneumatocek therapy with Chiba needle desuflation by CT control

    International Nuclear Information System (INIS)

    Mach, P.; Zachar, M.

    1996-01-01

    The authors demonstrated 18 month old girl with pneumatocele. In girl on accout of the persistence of of pneumatocele for more than eight an half month, regard to the localisation desuflation with Chiba needle under CT control was performed. After this procedure pneumatocele deminished in size and complete recovery occurred after for and half month. (authors). 5 figs., 8 refs

  7. Main flavonoids in needles of Larix decidu A

    NARCIS (Netherlands)

    Niemann, Gerard J.

    Present work. Freeze-dried needles were extracted with acetone-water. Ether and butanol fractions were separated by repeated banding on paper. Nine major flavonoids were isolated (in solution) and identified by chromatographic and UV spectral data of both the original and alkaline and/or acid

  8. A Cross Section Study to Correlate Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    ADMIN

    Background: Needle Aspiration Cytology (FNAC) is cheap, simple, quick, minimally invasive procedure that is widely used for preoperative diagnosis of Parotid tumours. Methods: Twenty five patients were prospectively studied over a two-year period at four major hospitals in Zambia. FNAC was done using a 10cc syringe ...

  9. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    diagnosis of palpable breast lesions, in recent years two types of minimally invasive .... negative predictive value of FNAC as a diagnostic pro- cedure for the entire ... The earliest large scale use of Fine Needle aspiration. Cytology FNAC as a ...

  10. Mountain Norway spruce forests: Needle supply and its nutrient content

    Czech Academy of Sciences Publication Activity Database

    Kovářová, Marcela; Vacek, S.

    2003-01-01

    Roč. 49, - (2003), s. 327-332 ISSN 1212-4834 R&D Projects: GA AV ČR KSK6005114; GA ČR GA206/99/1416 Institutional research plan: CEZ:AV0Z6005908 Keywords : Šumava Mts. * Mountain Norway spruce forest * needle mass Subject RIV: EF - Botanics

  11. Atom sharp needles, the missing link in microneedle drug delivery

    NARCIS (Netherlands)

    Wissink, J.; Berenschot, Johan W.; Tas, Niels Roelof

    2008-01-01

    The skin barrier function is a major challenge for delivery of drugs via the skin. Located in the outermost layer of the skin, the stratum corneum (SC) consists of dead cells embedded in lipid regions, only 10-20 microm thick, tough but flexible and elastic. Hyperdermic needles penetrate the skin

  12. Pressure on the conical surface of needle valves

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav

    2014-01-01

    Roč. 220, č. 1 (2014), s. 1-12 ISSN 0924-4247 R&D Projects: GA ČR GA13-23046S Institutional support: RVO:61388998 Keywords : nozzle * needle nozzle * flow separation Subject RIV: BK - Fluid Dynamics Impact factor: 1.903, year: 2014 http://www.sciencedirect.com/science/article/pii/S0924424714004087

  13. Applicability of the PROSPECT model for Norway spruce needles

    NARCIS (Netherlands)

    Malenovsky, Z.; Albrechtova, J.; Lhotakova, Z.; Zurita Milla, R.; Clevers, J.G.P.W.; Schaepman, M.E.; Cudlin, P.

    2006-01-01

    The potential applicability of the leaf radiative transfer model PROSPECT (version 3.01) was tested for Norway spruce (Picea abies (L.) Karst.) needles collected from stress resistant and resilient trees. Direct comparison of the measured and simulated leaf optical properties between 450¿1000 nm

  14. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  15. Morphea on the Breast after a Needle Biopsy

    OpenAIRE

    Arase, Noriko; Igawa, Ken; Senda, Satoko; Terao, Mika; Murota, Hiroyuki; Katayama, Ichiro

    2011-01-01

    Localized scleroderma (morphea) usually develops spontaneously, but the precise mechanisms underlying disease development are obscure. However, a significant number of cases suggest that morphea is induced by external stimuli. Herein, we report a case of morphea that developed after a needle biopsy.

  16. Competition of Scleroconidioma sphagnicola with fungi decomposing spruce litter needles

    Czech Academy of Sciences Publication Activity Database

    Koukol, Ondřej; Mrnka, Libor; Kulhánková, A.; Vosátka, Miroslav

    2006-01-01

    Roč. 84, - (2006), s. 469-476 ISSN 0008-4026 R&D Projects: GA ČR(CZ) GA206/05/0269 Institutional research plan: CEZ:AV0Z60050516 Keywords : litter needles * competition * agar pairing Subject RIV: EF - Botanics Impact factor: 1.193, year: 2006

  17. Thin-needle aspiration biopsy of the prostate.

    Science.gov (United States)

    Koss, L G; Woyke, S; Schreiber, K; Kohlberg, W; Freed, S Z

    1984-05-01

    The authors summarize the current status of thin-needle aspiration biopsy of the prostate and evaluate the accomplishments and limitations of this method of diagnosis. Historical developments, indications, technique, contraindications, complications, cytology of aspirates, diagnostic efficacy of aspirates, and grading of prostatic carcinomas are discussed.

  18. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    Science.gov (United States)

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  19. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  20. 21 CFR 884.6100 - Assisted reproduction needles.

    Science.gov (United States)

    2010-04-01

    ... vitro fertilization (IVF), gamete intrafallopian transfer (GIFT), or other assisted reproduction... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction needles. 884.6100 Section 884.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  1. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice

    NARCIS (Netherlands)

    Scholten, H.J.; Pourtaherian, A.; Mihajlovic, N.; Korsten, H.; Bouwman, R.A.

    2017-01-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging

  2. Options for reducing HIV transmission related to the dead space in needles and syringes.

    Science.gov (United States)

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  3. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  4. Quantitative radiography

    International Nuclear Information System (INIS)

    Brase, J.M.; Martz, H.E.; Waltjen, K.E.; Hurd, R.L.; Wieting, M.G.

    1986-01-01

    Radiographic techniques have been used in nondestructive evaluation primarily to develop qualitative information (i.e., defect detection). This project applies and extends the techniques developed in medical x-ray imaging, particularly computed tomography (CT), to develop quantitative information (both spatial dimensions and material quantities) on the three-dimensional (3D) structure of solids. Accomplishments in FY 86 include (1) improvements in experimental equipment - an improved microfocus system that will give 20-μm resolution and has potential for increased imaging speed, and (2) development of a simple new technique for displaying 3D images so as to clearly show the structure of the object. Image reconstruction and data analysis for a series of synchrotron CT experiments conducted by LLNL's Chemistry Department has begun

  5. Quantitative lymphography

    International Nuclear Information System (INIS)

    Mostbeck, A.; Lofferer, O.; Kahn, P.; Partsch, H.; Koehn, H.; Bialonczyk, Ch.; Koenig, B.

    1984-01-01

    Labelled colloids and macromolecules are removed lymphatically. The uptake of tracer in the regional lymphnodes is a parameter of lymphatic flow. Due to great variations in patient shape - obesity, cachexia - and accompanying variations in counting efficiencies quantitative measurements with reasonable accuracy have not been reported to date. A new approach to regional absorption correction is based on the combination of transmission and emission scans for each patient. The transmission scan is used for calculation of an absorption correction matrix. Accurate superposition of the correction matrix and the emission scan is achieved by computing the centers of gravity of point sources and - in the case of aligning opposite views - by cross correlation of binary images. In phantom studies the recovery was high (98.3%) and the coefficient of variation of repeated measurement below 1%. In patient studies a standardized stress is a prerequisite for reliable and comparable results. Discrimination between normals (14.3 +- 4.2D%) and patients with lymphedema (2.05 +- 2.5D%) was highly significant using praefascial lymphography and sc injection. Clearence curve analysis of the activities at the injection site, however, gave no reliable data for this purpose. In normals, the uptake in lymphnodes after im injection is by one order of magnitude lower then the uptake after sc injection. The discrimination between normals and patients with postthromboic syndrome was significant. Lymphography after ic injection was in the normal range in 2/3 of the patients with lymphedema and is therefore of no diagnostic value. The difference in uptake after ic and sc injection demonstrated for the first time by our quantitative method provides new insights into the pathophysiology of lymphedema and needs further investigation. (Author)

  6. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  7. Occurrence and knowledge about needle stick injury in nursing students

    International Nuclear Information System (INIS)

    Prasuna, J.; Sharma, R.

    2015-01-01

    Needle stick injury (NSI) became a major issue and most of the research focuses on Nurses, Doctors and other health care workers, but at the same time nursing students in clinical duties are at high risk. Studies are available which examined NSI only in Medical students and health care workers. The present study is aimed to measure the occurrence of needle stick injury along with post exposure measures and evaluation of the knowledge regarding needle stick injury among nursing student. Methods: A cross-sectional study was conducted in North-East India in 2013. The study participants comprised of 83 nursing students studying in 4th year B.Sc. (N) and 3rd year General Nursing and Midwifery (GNM). Students were questioned regarding their occurrence to Needle Stick Injury throughout their clinical training and measures taken following the exposure. They were also asked to complete the Knowledge questionnaire on NSI. Results: The study among 83 nursing students included 43 (51.81%) GNM 3rd year and 40 (48.19%) B.Sc. Nursing Students. Out of a total 83 students, 75 (90.36%) were females. The occurrence of NSI during their course was reported by 33 (39.76%) participants. The maximum NSI occurred during first year of course (57.57%). It was found that 18 (54.54%) of NSIs were not reported. Among those exposed, only 5 (15.15%) students had undergone blood investigation and very few students took post exposure measures. It was found that, only 23 (69.69%) students were immunized against Hepatitis B before NSI. Conclusion: The present study indicated a high incidence of needle stick injuries among nursing students with more under-reported cases and subjects were not aware of post exposure measures. It is essential to deal above problems by regular training on real-life procedure at the entry level and reporting system should be more user-friendly platform. (author)

  8. The Significance of Harm Reduction as a Social and Health Care Intervention for Injecting Drug Users: An Exploratory Study of a Needle Exchange Program in Fresno, California.

    Science.gov (United States)

    Clarke, Kris; Harris, Debra; Zweifler, John A; Lasher, Marc; Mortimer, Roger B; Hughes, Susan

    2016-01-01

    Infectious disease remains a significant social and health concern in the United States. Preventing more people from contracting HIV/AIDS or Hepatitis C (HCV), requires a complex understanding of the interconnection between the biomedical and social dimensions of infectious disease. Opiate addiction in the US has skyrocketed in recent years. Preventing more cases of HIV/AIDS and HCV will require dealing with the social determinants of health. Needle exchange programs (NEPs) are based on a harm reduction approach that seeks to minimize the risk of infection and damage to the user and community. This article presents an exploratory small-scale quantitative study of the injection drug using habits of a group of injection drug users (IDUs) at a needle exchange program in Fresno, California. Respondents reported significant decreases in high risk IDU behaviors, including sharing of needles and to a lesser extent re-using of needles. They also reported frequent use of clean paraphernalia. Greater collaboration between social and health outreach professionals at NEPs could provide important frontline assistance to people excluded from mainstream office-based services and enhance efforts to reduce HIV/AIDS or HCV infection.

  9. Numerical Modelling of Mutual Effect among Nearby Needles in a Multi-Needle Configuration of an Atmospheric Air Dielectric Barrier Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2012-05-01

    Full Text Available A numerical study has been conducted to understand the mutual effect among nearby needles in a multi-needle electrode dielectric barrier discharge. In the present paper, a fluid-hydrodynamic model is adopted. In this model, the mutual effect among nearby needles in a multi-needle configuration of an atmospheric air dielectric barrier discharge are investigated using a fluid-hydrodynamic model including the continuity equations for electrons and positive and negative ions coupled with Poisson’s equation. The electric fields at the streamer head of the middle needle (MN and the side needles (SNs in a three-needle model decreased under the influence of the mutual effects of nearby needles compared with that in the single-needle model. In addition, from the same comparison, the average propagation velocities of the streamers from MN and SNs, the electron average energy profile of MN and SNs (including those in the streamer channel, at the streamer head, and in the unbridged gap, and the electron densities at the streamer head of the MN and SNs also decreased. The results obtained in the current paper agreed well with the experimental and simulation results in the literature.

  10. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  11. Inserting needles into the body: a meta-analysis of brain activity associated with acupuncture needle stimulation.

    Science.gov (United States)

    Chae, Younbyoung; Chang, Dong-Seon; Lee, Soon-Ho; Jung, Won-Mo; Lee, In-Seon; Jackson, Stephen; Kong, Jian; Lee, Hyangsook; Park, Hi-Joon; Lee, Hyejung; Wallraven, Christian

    2013-03-01

    Acupuncture is a therapeutic treatment that is defined as the insertion of needles into the body at specific points (ie, acupoints). Advances in functional neuroimaging have made it possible to study brain responses to acupuncture; however, previous studies have mainly concentrated on acupoint specificity. We wanted to focus on the functional brain responses that occur because of needle insertion into the body. An activation likelihood estimation meta-analysis was carried out to investigate common characteristics of brain responses to acupuncture needle stimulation compared to tactile stimulation. A total of 28 functional magnetic resonance imaging studies, which consisted of 51 acupuncture and 10 tactile stimulation experiments, were selected for the meta-analysis. Following acupuncture needle stimulation, activation in the sensorimotor cortical network, including the insula, thalamus, anterior cingulate cortex, and primary and secondary somatosensory cortices, and deactivation in the limbic-paralimbic neocortical network, including the medial prefrontal cortex, caudate, amygdala, posterior cingulate cortex, and parahippocampus, were detected and assessed. Following control tactile stimulation, weaker patterns of brain responses were detected in areas similar to those stated above. The activation and deactivation patterns following acupuncture stimulation suggest that the hemodynamic responses in the brain simultaneously reflect the sensory, cognitive, and affective dimensions of pain. This article facilitates a better understanding of acupuncture needle stimulation and its effects on specific activity changes in different brain regions as well as its relationship to the multiple dimensions of pain. Future studies can build on this meta-analysis and will help to elucidate the clinically relevant therapeutic effects of acupuncture. Copyright © 2013 American Pain Society. All rights reserved.

  12. Textiles: Some technocal information and data IV: sewability, sewing needles, threads and seams.

    CSIR Research Space (South Africa)

    Hunter, L

    1979-09-01

    Full Text Available half in about four c~ro"dd5 - - - - . . - - . Reducing the needle \\docity during its contact with the fabric can reduce needle temocratures bv about 50°C although other workers found the differences ;o be only 5 to IPC14. ~adiation plays a minor..., may have led to the confusion concerning the relative merits of different needle point30. Needle point shape does not appear to significantly affect maximum penetration force or energy~ expended while bulged-eye needles reduce heat build...

  13. Effects of irrigation, fertilization and drought on the occurrence of Lophodermium piceae in Picea abies needles

    Energy Technology Data Exchange (ETDEWEB)

    Lehtijaervi, Asko; Barklund, Pia [Swedish Univ. of Agricultural Sciences, Uppsala (Sweden). Dept. of Forest Mycology and Pathology

    1999-08-01

    Effects of irrigation, drought and fertilization on the frequency of the fungal endophyte Lophodermium piceae in green needles was assessed in a 30-year-old experimental stand of Picea abies in southern Sweden. Frequencies of needles with L. piceae were lower in irrigation and ammonium sulphate fertilization treatments than in the control. Drought treatment frequencies were similar to the control. Needles were susceptible to colonization for at least 3 years; colonization increased with needle age. The results indicate that the increased availability of water to the root system as well as ammonium sulphate fertilization indirectly delays colonization of needles by L. piceae 21 refs, 3 figs, 2 tabs

  14. Possibilities of the chemical analysis of Scots pine (Pinus sylvestris) needles

    International Nuclear Information System (INIS)

    Viksna, A.

    1999-01-01

    Scots pine (Pinus sylvestris L.) is a good bio indicator. This species is widely distributed in Europe, including Latvia, is easily identified, and is used in bio indication studies. It is known that the concentrations of most elements in needles change with time. These changes are connected to the processes involved in the uptake, transportation, storage and retranslocation of the elements. Scots pine keeps their needles for several years (3 to 4 years) and are suitable for the study of time related processes. The chemical composition of pine needles is used for the study the deposition and impact of air pollutants. Coniferous needles are covered with epicuticular wax, which act as a trap for airborne deposits. A comparison of chemical composition of pine needles that were unwashed and washed with chloroform made it possible to distinguish which elements were on the needles and to evaluate the character of pollution. The most important stage of the analysis of pine needles is sampling. Nutrient concentrations in the needles of coniferous trees have been shown to vary with the needle age and tree age, the phase of the annual physiological cycle, availability of nutrients in the soil and needle position within the crown. It is very important to take representative sample for the analysis. In the current work the trace element concentrations of the single needle were analysed by electrothermal atomic absorption spectrometry (ETAAS) and total reflection X-ray spectrometry (TXRF). The results of analysis showed that concentration of some elements depends from the position of needle within branch for the same needle age class. The concentrations of trace elements in the single needles within main shoot were more or less constant compare with other order shoots at given needle age class. Some higher variations in the elemental concentrations between single needles were observed in the tip part of main shoot. The actual distribution of the elements within a needle has

  15. Quantitative Thermochronology

    Science.gov (United States)

    Braun, Jean; van der Beek, Peter; Batt, Geoffrey

    2006-05-01

    Thermochronology, the study of the thermal history of rocks, enables us to quantify the nature and timing of tectonic processes. Quantitative Thermochronology is a robust review of isotopic ages, and presents a range of numerical modeling techniques to allow the physical implications of isotopic age data to be explored. The authors provide analytical, semi-analytical, and numerical solutions to the heat transfer equation in a range of tectonic settings and under varying boundary conditions. They then illustrate their modeling approach built around a large number of case studies. The benefits of different thermochronological techniques are also described. Computer programs on an accompanying website at www.cambridge.org/9780521830577 are introduced through the text and provide a means of solving the heat transport equation in the deforming Earth to predict the ages of rocks and compare them directly to geological and geochronological data. Several short tutorials, with hints and solutions, are also included. Numerous case studies help geologists to interpret age data and relate it to Earth processes Essential background material to aid understanding and using thermochronological data Provides a thorough treatise on numerical modeling of heat transport in the Earth's crust Supported by a website hosting relevant computer programs and colour slides of figures from the book for use in teaching

  16. In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Clark, Douglas; Sherman, Jason; Fuller, Dave; Messing, Edward; Rubens, Deborah; Strang, John; Brasacchio, Ralph; Liao, Lydia; Ng, W.-S.; Yu Yan

    2006-01-01

    In this paper, we present needle insertion forces and motion trajectories measured during actual brachytherapy needle insertion while implanting radioactive seeds in the prostate glands of 20 different patients. The needle motion was captured using ultrasound images and a 6 degree-of-freedom electromagnetic-based position sensor. Needle velocity was computed from the position information and the corresponding time stamps. From in vivo data we found the maximum needle insertion forces to be about 15.6 and 8.9 N for 17 gauge (1.47 mm) and 18 gauge (1.27 mm) needles, respectively. Part of this difference in insertion forces is due to the needle size difference (17G and 18G) and the other part is due to the difference in tissue properties that are specific to the individual patient. Some transverse forces were observed, which are attributed to several factors such as tissue heterogeneity, organ movement, human factors in surgery, and the interaction between the template and the needle. However, theses insertion forces are significantly responsible for needle deviation from the desired trajectory and target movement. Therefore, a proper selection of needle and modulated velocity (translational and rotational) may reduce the tissue deformation and target movement by reducing insertion forces and thereby improve the seed delivery accuracy. The knowledge gleaned from this study promises to be useful for not only designing mechanical/robotic systems but also developing a predictive deformation model of the prostate and real-time adaptive controlling of the needle

  17. Precision grid and hand motion for accurate needle insertion in brachytherapy

    International Nuclear Information System (INIS)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J.

    2011-01-01

    Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2 3 factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

  18. Are needle-free injections a useful alternative for growth hormone therapy in children? Safety and pharmacokinetics of growth hormone delivered by a new needle-free injection device compared to a fine gauge needle.

    NARCIS (Netherlands)

    Dorr, H.G.; Zabransky, S.; Keller, E.; Otten, B.J.; Partsch, C.J.; Nyman, L.; Gillespie, B.K.; Lester, N.R.; Wilson, A.M.; Hyren, C.; Kuijck, M.A. van; Schuld, P.; Schoenfeld, S.L.

    2003-01-01

    The clinical safety, use and pharmacokinetics of a new needle-free device for delivery of growth hormone (GH) were compared with those of conventional needle injection devices. In an open-label, randomized, 4-period crossover study, 18 healthy adults received single subcutaneous injections of

  19. The longitudinal distribution of elements in developing and aging scots pine needles

    International Nuclear Information System (INIS)

    Viksna, A.; Helmisaari, H.S.; Standzenieks, P.; Lindgren, E.S.

    2001-01-01

    Needle or leaf nutrient concentrations are commonly used for analysing tree nutritional status for e.g. estimating possible nutrient deficiencies or unbalances. The practise used e.g. in northern Europe is to sample needles during the dormant period from either the current or in some cases several needle age classes from a fixed position of a number of trees in a stand. The sampled needles are then dried and ground for nutrient analysis. The sampling aims to minimise the spatial and temporal variation in needle nutrient concentrations for estimating the availability of nutrients in soil through needle analysis. It is well known that the concentrations of different nutrients vary in needles with the phase of the annual physiological cycle (Fife and Nambiar 1982, 1984), needle age (Florence and Chuoung 1974, Madgwick et al. 1983) and sampling position (Helmisaari 1992). The samples analysed are usually bulk samples of a large number of needles, and the results are mean concentrations representing an age class in a stand. There is little information on how different needles vary in nutrient concentrations, and even less on how nutrient concentrations vary within individual needles. The import and export of elements to and from needles varies according to the developmental phase of needles, and is likely to affect the element concentrations in different parts of the needles. Accordingly, the elemental concentrations measured in different parts of the needles may give an insight into the transport pattern of an element and its potential mobility. Up to now, very few studies report needle element concentrations in different parts of the needles, e.g. tip, base and middle (Giertych et al. 1997), or in different parts of the leaf phloem (Eschrich et al. 1988). The aim of this study was to determine the distribution of different elements along the length of single Scots pine needles of different age and during different stages of needle physiological cycle. The scanning

  20. A comparison of epicuticular wax of Pinus sylvestris needles from three sites in Ireland

    International Nuclear Information System (INIS)

    Donnelly, A.; Dowding, P.

    1994-01-01

    Three forest stands of Pinus sylvestris were chosen for comparison in Ireland. Needles from three year classes were collected. Cuticular transpiration curves showed that the rate of water loss from 1-year-old needles was faster than either 2-year-old or current-year needles at all sites. The amount of epicuticular wax extracted was similar to that reported in the literature. Needle wettability increased with needle age. Amorphous wax coverage was estimated using scanning electron microscopy (SEM) and was found to increase with needle age. Algal cells were noted on needles of all ages at one site and appeared to affect transpiration and microroughness. The presence of fungal hyphae was also noted. (orig.)

  1. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  2. The quantitative Morse theorem

    OpenAIRE

    Loi, Ta Le; Phien, Phan

    2013-01-01

    In this paper, we give a proof of the quantitative Morse theorem stated by {Y. Yomdin} in \\cite{Y1}. The proof is based on the quantitative Sard theorem, the quantitative inverse function theorem and the quantitative Morse lemma.

  3. Structure and photoluminescence properties of Ag-coated ZnO nano-needles

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaozhu, E-mail: Lixiaozhu1019@21cn.com [Department of Physics, Shaoguan University, Shaoguan, Guangdong 512005 (China) and Department of Physics and Key Laboratory of Acoustic and Photonic Materials and Devices of Ministry of Education, Wuhan University, Wuhan, Hubei 430072 (China); Wang Yongqian [Engineering Research Center of Nano-Geomaterials of Ministry of Education (China University of Geosciences), Wuhan, Hubei 430074 (China)

    2011-05-12

    Highlights: > ZnO nano-needles were synthesized by thermal oxidation. > Their surfaces were coated with Ag by pulse electro-deposition technique. > The uncoated and coated ZnO nano-needles were characterized. > The results showed that the prepared ZnO nano-needles have been coated with Ag successfully. > The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the Ag-coated ZnO nano-needles can increase the absorption of UV light. - Abstract: A large number of zinc oxide (ZnO) nano-needles were synthesized by thermal oxidation of pure zinc. The surfaces of ZnO nano-needles were coated with a layer of Ag by pulse electro-deposition technique. The uncoated and coated ZnO nano-needles were characterized by using the X-ray diffraction and the scanning electron microscope (SEM). The results showed that the uncoated samples were close-packed hexagonal structure, which showed needle-like morphology. Their average diameter is about 40 nm, lengths up to 5 {mu}m. At the same time we observed that the prepared ZnO nano-needles have been coated with Ag successfully. The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the uncoated ZnO nano-needles have two fluorescence peaks at 388 nm and 470.8 nm, respectively, the relative intensity of 143.4 and 93.61; and the Ag-coated ZnO nano-needles showed a pair of strong peaks at 387.4 nm and 405.2 nm, the relative intensity of 1366 and 1305, respectively, indicating that the Ag-coated ZnO nano-needles can increase the absorption of UV light.

  4. Structure and photoluminescence properties of Ag-coated ZnO nano-needles

    International Nuclear Information System (INIS)

    Li Xiaozhu; Wang Yongqian

    2011-01-01

    Highlights: → ZnO nano-needles were synthesized by thermal oxidation. → Their surfaces were coated with Ag by pulse electro-deposition technique. → The uncoated and coated ZnO nano-needles were characterized. → The results showed that the prepared ZnO nano-needles have been coated with Ag successfully. → The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the Ag-coated ZnO nano-needles can increase the absorption of UV light. - Abstract: A large number of zinc oxide (ZnO) nano-needles were synthesized by thermal oxidation of pure zinc. The surfaces of ZnO nano-needles were coated with a layer of Ag by pulse electro-deposition technique. The uncoated and coated ZnO nano-needles were characterized by using the X-ray diffraction and the scanning electron microscope (SEM). The results showed that the uncoated samples were close-packed hexagonal structure, which showed needle-like morphology. Their average diameter is about 40 nm, lengths up to 5 μm. At the same time we observed that the prepared ZnO nano-needles have been coated with Ag successfully. The photoluminescence spectrums of ZnO nano-needles with Ag-coated and uncoated were analyzed, finding that the uncoated ZnO nano-needles have two fluorescence peaks at 388 nm and 470.8 nm, respectively, the relative intensity of 143.4 and 93.61; and the Ag-coated ZnO nano-needles showed a pair of strong peaks at 387.4 nm and 405.2 nm, the relative intensity of 1366 and 1305, respectively, indicating that the Ag-coated ZnO nano-needles can increase the absorption of UV light.

  5. Relationship between lower limb position and pelvic floor muscle surface electromyography activity in menopausal women: a prospective observational study

    Directory of Open Access Journals (Sweden)

    Halski T

    2017-01-01

    Full Text Available Tomasz Halski,1 Kuba Ptaszkowski,2 Lucyna Słupska,1 Robert Dymarek,3 Małgorzata Paprocka-Borowicz2 1Department of Physiotherapy, Opole Medical School, Opole, 2Department of Clinical Biomechanics and Physiotherapy in Motor System Disorders, 3Department of Nervous System Diseases, Faculty of Health Science, Wroclaw Medical University, Wroclaw, Poland Objectives: In physiotherapeutic practice, special attention is being given to the reciprocal anatomical, physiological, and biomechanical relationship of the pelvis and the structures connected to it. However, the scientific literature shows mainly the theoretical information about their mutual connections. The lack of information about these relations from a practical aspect coupled with the paucity of scientific papers on the impact of posture changes on the pelvic floor led the authors to conduct this study. The primary aim of this study was to compare the resting and functional bioelectrical activities of pelvic floor muscles (PFMs depending on three different positions of the lower limbs (positions A, B, and C in the supine position.Materials and methods: This was a prospective observational study evaluating resting and functional activities of the PFM depending on the position of the lower limbs. The study was carried out at the Department and Clinic of Urology, University Hospital in Wroclaw, Poland and the target group were women in the menopausal period. Bioelectrical activity of PFM was recorded using a surface electromyographic instrument in the supine position. Results of the values obtained in A, B, and C positions were compared using a one-way analysis of variance.Results: In position A, the average resting surface electromyography (sEMG activity of PFM was 6.9±2.6 µV; in position B, the result was 6.9±2.5 µV and in position C, the resting sEMG activity was 5.7±1.8 µV (P=0.0102. The results of the functional bioelectrical activity of PFM were as follows: position A – 20.3

  6. Development of a 3D workspace shoulder assessment tool incorporating electromyography and an inertial measurement unit-a preliminary study.

    Science.gov (United States)

    Aslani, Navid; Noroozi, Siamak; Davenport, Philip; Hartley, Richard; Dupac, Mihai; Sewell, Philip

    2018-06-01

    Traditional shoulder range of movement (ROM) measurement tools suffer from inaccuracy or from long experimental setup times. Recently, it has been demonstrated that relatively low-cost wearable inertial measurement unit (IMU) sensors can overcome many of the limitations of traditional motion tracking systems. The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. Six volunteer subjects with healthy shoulders and one participant with a 'frozen' shoulder were recruited to the study. Arm movement in 3D space was plotted in spherical coordinates while the relative EMG intensity of any arm position is presented graphically. The results showed that there was an average ROM surface area of 27291 ± 538 deg 2 among all six healthy individuals and a ROM surface area of 13571 ± 308 deg 2 for the subject with frozen shoulder. All three sections of the deltoid show greater EMG activity at higher elevation angles. Using such tools enables individuals, surgeons and physiotherapists to measure the maximum envelope of motion in conjunction with muscle activity in order to provide an objective assessment of shoulder performance in the voluntary 3D workspace. Graphical abstract The aim of this study is to develop and evaluate a single IMU combined with an electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. The assessment tool consists of an IMU sensor, an EMG sensor, a microcontroller and a Bluetooth module. The assessment tool was attached to subjects arm. Individuals were instructed to move their arms with the elbow fully extended. They were then asked to provide the maximal voluntary elevation envelope of the arm in 3D space in multiple attempts starting from a small movement envelope going to the biggest

  7. Fine-needle cytology of breast lesions seen on mammograms

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Ridlen, M.S.; Dowlatshahi, K.; Jokich, P.M.; Bibbo, M.

    1989-01-01

    Stereotactic fine-needle aspiration of nonpalpable breast lesions is operator dependent. The authors have analyzed 250 biopsies at our institution (comparing aspiration cytology with surgical biopsy) for sensitivity, false-negative, and insufficient-sample rates of three different interpreters. Needle aspiration as an alternative to biopsy or a follow-up for lesions of low mammographic suspicion would have resulted in detection of most, but not all, cancers. Over 40 additional biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies for low-suspicion lesions could be avoided. Aspiration cytologic series should report separately insufficient samples and LCIS, and should use a consistent threshold for interpreting cytologic results

  8. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  9. Interferon and the fear of needles: a case report.

    Science.gov (United States)

    López, Maria; Moreno, Laura; Dosal, Angelina; Pujol, Marta Maria; Vergara, Mercedes; Gil, Montserrat

    2011-01-01

    The treatment of viral hepatitis C infection uses a combination of pegylated interferon and ribavirin. Psychological preparation of the patient is vital to ensure adherence to the treatment. In our center, the nurse prepares this treatment according to an established educative protocol; however, some patients have special needs that require individualized attention. One such situation observed by the nurse is that the patients frequently admit to the fear of needle puncture (the peginterferon treatment is administered subcutaneously) and are unable to inject themselves. We describe a representative case and the care plan to manage the patient's fear so that the patient acquires confidence in his or her ability to self-inject. This facilitates autonomy and coresponsibility for the treatment, and the nurse can develop care approaches to combat the patient's fear of needles.

  10. Silica needle template fabrication of metal hollow microneedle arrays

    International Nuclear Information System (INIS)

    Zhu, M W; Li, H W; Chen, X L; Tang, Y F; Lu, M H; Chen, Y F

    2009-01-01

    Drug delivery through hollow microneedle (HMN) arrays has now been recognized as one of the most promising techniques because it minimizes the shortcomings of the traditional drug delivery methods and has many exciting advantages—pain free and tunable release rates, for example. However, this drug delivery method has been hindered greatly from mass clinical application because of the high fabrication cost of HMN arrays. Hence, we developed a simple and cost-effective procedure using silica needles as templates to massively fabricate HMN arrays by using popular materials and industrially applicable processes of micro- imprint, hot embossing, electroplating and polishing. Metal HMN arrays with high quality are prepared with great flexibility with tunable parameters of area, length of needle, size of hollow and array dimension. This efficient and cost-effective fabrication method can also be applied to other applications after minor alterations, such as preparation of optic, acoustic and solar harvesting materials and devices

  11. Needles of Pinus halepensis as biomonitors of bioaerosol emissions.

    Directory of Open Access Journals (Sweden)

    Amandine Galès

    Full Text Available We propose using the surface of pine trees needles to biomonitor the bioaerosol emissions at a composting plant. Measurements were based on 16S rRNA gene copy numbers of Saccharopolyspora rectivirgula, a bioindicator of composting plant emissions. A sampling plan was established based on 29 samples around the emission source. The abundance of 16S rRNA gene copies of S. rectivirgula per gram of Pinus halepensis needles varied from 104 to 102 as a function of the distance. The signal reached the background level at distances around the composting plant ranging from 2 km to more than 5.4 km, depending on the local topography and average wind directions. From these values, the impacted area around the source of bioaerosols was mapped.

  12. Uranium solubility and solubility controls in selected Needle's Eye groundwaters

    International Nuclear Information System (INIS)

    Falck, W.E.; Hooker, P.J.

    1992-01-01

    The British Geological Survey (BGS) has been co-ordinating a research programme centred on the Needle's Eye natural analogue site in Dumfries and Galloway District, southwest Scotland. This study of a natural radioactive geochemical system has been carried out with the aim of improving confidence in using geochemical and predictive models of radionuclide (uranium) migration in the geosphere. The Needle's Eye site is located on the Solway Coat within the Southwick Coast Reserve of the Scottish Wildlife Trust who gave permission to sample for soils, sediments and waters for analysis. This report is one of a series and covers the period from June 1989 to June 1990. It presents the results of applying the PHREEQE code to the hydrochemistry of the site using the CHEMVAL thermodynamic database. (author)

  13. Silica needle template fabrication of metal hollow microneedle arrays

    Science.gov (United States)

    Zhu, M. W.; Li, H. W.; Chen, X. L.; Tang, Y. F.; Lu, M. H.; Chen, Y. F.

    2009-11-01

    Drug delivery through hollow microneedle (HMN) arrays has now been recognized as one of the most promising techniques because it minimizes the shortcomings of the traditional drug delivery methods and has many exciting advantages—pain free and tunable release rates, for example. However, this drug delivery method has been hindered greatly from mass clinical application because of the high fabrication cost of HMN arrays. Hence, we developed a simple and cost-effective procedure using silica needles as templates to massively fabricate HMN arrays by using popular materials and industrially applicable processes of micro- imprint, hot embossing, electroplating and polishing. Metal HMN arrays with high quality are prepared with great flexibility with tunable parameters of area, length of needle, size of hollow and array dimension. This efficient and cost-effective fabrication method can also be applied to other applications after minor alterations, such as preparation of optic, acoustic and solar harvesting materials and devices.

  14. A eletromiografia como auxílio na conduta terapêutica após cirurgia de craniotomia fronto-temporal: relato de caso Electromyography as an aid in therapeutic behavior after fronto-temporal craniotomy surgery: case report

    Directory of Open Access Journals (Sweden)

    Maristella Cecco Oncins

    2009-01-01

    insertion. After the surgery, the patient had dysfunction in temporal muscle and in temporo-mandibular joint, with reduction of the opening of mouth, pain while speaking and eating. Electromyography was used to quantitatively record the electrical activity of the temporal and masseter muscles in the initial evaluation and during the therapeutic process. Records were made at rest position, maximum occlusion and chew. They did miofuncional therapy throughout the process. RESULTS: examination data showed a significant increase in the electrical activity of the right anterior temporal muscle and a reduction in the activity of the left anterior temporal muscle. The initial Record showed a lower electrical activity on the right side compared to the left. With the miofunctional exercises there was a more effective participation of the right anterior temporal muscle, greater openness of mouth, without pain, making easier chewing and speech tasks, harmonizing the stomatognathic system. CONCLUSION: comparative records concerning electromyography in different stages of the therapeutic process helped and directed the best therapy, achieving a balance concerning the functions of breathing, sucking, chewing, swallowing and speech related to the stomatognathic system, considering the limitations of the case.

  15. Deactivation of Escherichia coli by the plasma needle

    International Nuclear Information System (INIS)

    Sladek, R E J; Stoffels, E

    2005-01-01

    In this paper we present a parameter study on deactivation of Escherichia coli (E. coli) by means of a non-thermal plasma (plasma needle). The plasma needle is a small-sized (1 mm) atmospheric glow sustained by radio-frequency excitation. This plasma will be used to disinfect heat-sensitive objects; one of the intended applications is in vivo deactivation of dental bacteria: destruction of plaque and treatment of caries. We use E. coli films plated on agar dishes as a model system to optimize the conditions for bacterial destruction. Plasma power, treatment time and needle-to-sample distance are varied. Plasma treatment of E. coli films results in formation of a bacteria-free void with a size up to 12 mm. 10 4 -10 5 colony forming units are already destroyed after 10 s of treatment. Prolongation of treatment time and usage of high powers do not significantly improve the destruction efficiency: short exposure at low plasma power is sufficient. Furthermore, we study the effects of temperature increase on the survival of E. coli and compare it with thermal effects of the plasma. The population of E. coli heated in a warm water bath starts to decrease at temperatures above 40 deg. C. Sample temperature during plasma treatment has been monitored. The temperature can reach up to 60 deg. C at high plasma powers and short needle-to-sample distances. However, thermal effects cannot account for bacterial destruction at low power conditions. For safe and efficient in vivo disinfection, the sample temperature should be kept low. Thus, plasma power and treatment time should not exceed 150 mW and 60 s, respectively

  16. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  17. [Treatment of trigger finger with located needle knife].

    Science.gov (United States)

    Zhang, Qi-Feng; Yang, Jiang; Xi, Sheng-Hua

    2016-07-25

    To investigate the clinical effects of located needle knife in the treatment of trigger finger. The clinical data of 133 patients(145 fingers) with trigger finger underwent treatment with located needle knife from September 2010 to March 2014 were retrospectively analyzed. There were 37 males(40 fingers) and 96 females (105 fingers), aged from 18 to 71 years old with a mean of 51.8 years. Course of disease was from 1 to 19 months with an average of 8.2 months. Affected fingers included 82 thumbs, 12 index fingers, 11 middle fingers, 36 ring fingers, and 4 little fingers. According to the standard of Quinnell grade, 42 fingers were grade III, 92 fingers were grade IV, and 11 fingers were grade V. Firstly the double pipe gab was put into the distal edge of hypertrophic tendon sheath, then small knife needle was used to release the sheath proximally along the tendon line direction. The informations of wound healing and nerve injury, postoperative finger function, finger pain at 6 months were observed. The operation time was from 8 to 25 min with an average of 9.8 min. All the patients were followed up from 6 to 26 months with an average of 12.5 months. No complications such as the wound inflammation and seepage, vascular or nerve injuries were found. According to the standard of Quinnell grade, 123 fingers got excellent results, 15 good, 7 poor. It's a good choice to treat trigger finger with located needle knife in advantage of minimal invasion, simple safe operation, and it should be promoted in clinic.

  18. Diagnostic accuracy of fine needle aspiration cytology in hepatic tumours

    International Nuclear Information System (INIS)

    Nazir, R.T.; Sharif, M.A.; Iqbal, M.; Amin, M.S.

    2010-01-01

    To determine the diagnostic accuracy of fine-needle aspiration cytology (FNAC) in liver masses to isolate malignant from benign tumours and hepatocellular carcinoma (HCC) from metastatic tumours. Study Design: Cross-sectional, observational. Place and Duration of Study: Department of Histopathology, Combined Military Hospital, Peshawar, from June 2004 to June 2005. Methodology: All the patients with liver masses confirmed by ultrasonography, irrespective of age and gender, were included. Patients with inflammatory lesions were excluded from the study. Selected patients underwent fine-needle aspiration under ultrasound guidance followed by needle biopsy. The cytological slides were stained by haematoxylin and eosin (H and E) stain, while Papanicolaou's stain was employed in selective cases. Needle biopsy fragments were fixed in formalin followed by paraffin embedding and staining with H and E stain. Sensitivity and specificity of FNAC in the diagnosis of liver masses was determined using histological diagnosis on liver biopsy as gold standard. Results: There were one hundred subjects. The mean age at presentation was 55 +- 12 years with male to female ratio of 1.7:1. Cytological diagnosis in 19 cases was benign/non-neoplastic and 81 was malignant. Out of the latter, 49 (60.49%) were HCC and 32 (39.51%) were metastatic tumours on cytology. The overall sensitivity, specificity and accuracy of FNAC in the diagnosis of malignant lesions was 95.2%, 100% and 96% respectively using histological diagnosis on liver biopsy as gold standard. Sensitivity of FNAC to differentiate HCC from metastatic tumours in liver was 96% while specificity was 100% having a diagnostic accuracy of 97.5%. The discrepancy in cyto-histological comparison was mainly seen in well differentiated and poorly-differentiated HCCs. Conclusion: FNAC of the liver masses is a simple, safe, accurate, economical screening test without significant morbidity that can be used to identify the vast majority of

  19. Understanding the Physiology of Postharvest Needle Abscission in Balsam Fir

    OpenAIRE

    Lada, Rajasekaran R.; MacDonald, Mason T.

    2015-01-01

    Balsam fir (Abies balsamea) trees are commonly used as a specialty horticultural species for Christmas trees and associated greenery in eastern Canada and United States. Postharvest needle abscission has always been a problem, but is becoming an even bigger challenge in recent years presumably due to increased autumn temperatures and earlier harvesting practices. An increased understanding of postharvest abscission physiology in balsam fir may benefit the Christmas tree industry while simulta...

  20. Optimisation of steam extraction of oil from maritime pine needles

    OpenAIRE

    Rezzoug , Sid-Ahmed

    2009-01-01

    International audience; Essential oil from pine maritime needles is generally extracted by steam distillation process at atmospheric pressure for more than one hour, or by solvent extraction process. In the last decade, there has been an increasing demand for new extraction techniques enabling automation, shorter extraction time and reduced consumption of organic solvent. In this study, Response Surface Methodology (RSM) was used to evaluate the effects of two processing parameters of an alte...

  1. NEEDLE REVISION WITH MITOMYCIN-C IN ENCAPSULATED BLEBS

    Directory of Open Access Journals (Sweden)

    R Zarei

    2008-08-01

    Full Text Available "nThe most common cause of failure during the first trimester after trabeculectomy is encapsulated bleb and needling bleb revision is a less invasive method in the management of refractory cases. The purpose of this study is to determine the efficacy and safety of mitomycin-C (MMC augmented bleb revision of failed filtration surgery. This study is a before-after (paired observation. 33 patients with failed trabeculectomy because of bleb encapsulation, whose intraocular pressure (IOP was not reduced under 21 mmHg despite of medications and digital massage , underwent needling bleb revision and subconjunctival injection of 0.1 ml MMC (0.4 mg/ml.The mean follow-up time was 9.24 ± 5.27 months (1-20 months. Statistical analysis of the data included the paired two-tailed Student's t test for preoperative and postoperative IOP and number of medications. 36 needling procedures (mean, 1.09 ± 0.21 revisions per eye were performed on 33 eyes. Patients were between 10-80 years old (mean, 45.67 ± 22.41 years and mean follow-up was 9.24 ± 5.27 months. IOP decreased from 29.06 ± 5.03 mmHg to 18.21 ± 6.76 mmHg at last follow-up (P= 0.000. Antiglaucoma medications decreased from 2.18 ± 0.58 to 1.36 ± 0.29 at last follow-up (P= 0.000.Overall, 6 (18.2% of 33 cases achieved a complete success and 20 (60.6% of cases achieved a qualified success. The complications of this procedure were subconjunctival hemorrhage (17 cases, hyphema (5 cases and conjunctival button hole (2 cases. Needling bleb revision with mitomycin-C appears to be an effective and relatively safe way to revive failed filtration surgery.

  2. Applicability of the PROSPECT model for Norway spruce needles

    Czech Academy of Sciences Publication Activity Database

    Malenovský, Zbyněk; Albrechtová, J.; Lhotáková, Z.; Zurita-Milla, R.; Clevers, J.G.P.W.; Schaepman, M.E.; Cudlín, Pavel

    2006-01-01

    Roč. 27, 23-24 (2006), s. 5315-5340 ISSN 0143-1161 R&D Projects: GA MŠk 1K04121 Institutional research plan: CEZ:AV0Z60870520 Keywords : chlorophyll content estimation * canopy reflectance models * radiative-transfer models * remote-sensing data * leaf-area index * optical-properties * conifer needles * forest * vegetation * inversion Subject RIV: GK - Forest ry Impact factor: 0.980, year: 2006

  3. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    OpenAIRE

    Limmer, Alexandra M.; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was ...

  4. Periocular hematoma secondary to subperiosteal injury by a short needle

    Directory of Open Access Journals (Sweden)

    Nauman Ahmad

    2012-01-01

    Full Text Available Bleeding and intraorbital hematoma is one of the most common complications of needle block for ophthalmic local anesthesia. We describe an unusual presentation of hematoma that originated in the subperiosteal space and extended to the subconjunctival and periocular area after a peribulbar block for phacoemulsification in a 55-year-old lady. It required an urgent surgical evacuation in order to reduce the intraocular pressure and save the eye. Detailed management to improve the outcome is discussed.

  5. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    Science.gov (United States)

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  6. High resolution microphotonic needle for endoscopic imaging (Conference Presentation)

    Science.gov (United States)

    Tadayon, Mohammad Amin; Mohanty, Aseema; Roberts, Samantha P.; Barbosa, Felippe; Lipson, Michal

    2017-02-01

    GRIN (Graded index) lens have revolutionized micro endoscopy enabling deep tissue imaging with high resolution. The challenges of traditional GRIN lenses are their large size (when compared with the field of view) and their limited resolution. This is because of the relatively weak NA in standard graded index lenses. Here we introduce a novel micro-needle platform for endoscopy with much higher resolution than traditional GRIN lenses and a FOV that corresponds to the whole cross section of the needle. The platform is based on polymeric (SU-8) waveguide integrated with a microlens micro fabricated on a silicon substrate using a unique molding process. Due to the high index of refraction of the material the NA of the needle is much higher than traditional GRIN lenses. We tested the probe in a fluorescent dye solution (19.6 µM Alexa Flour 647 solution) and measured a numerical aperture of 0.25, focal length of about 175 µm and minimal spot size of about 1.6 µm. We show that the platform can image a sample with the field of view corresponding to the cross sectional area of the waveguide (80x100 µm2). The waveguide size can in principle be modified to vary size of the imaging field of view. This demonstration, combined with our previous work demonstrating our ability to implant the high NA needle in a live animal, shows that the proposed system can be used for deep tissue imaging with very high resolution and high field of view.

  7. Deactivation of Escherichia coli by the plasma needle

    Energy Technology Data Exchange (ETDEWEB)

    Sladek, R E J; Stoffels, E [Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands)

    2005-06-07

    In this paper we present a parameter study on deactivation of Escherichia coli (E. coli) by means of a non-thermal plasma (plasma needle). The plasma needle is a small-sized (1 mm) atmospheric glow sustained by radio-frequency excitation. This plasma will be used to disinfect heat-sensitive objects; one of the intended applications is in vivo deactivation of dental bacteria: destruction of plaque and treatment of caries. We use E. coli films plated on agar dishes as a model system to optimize the conditions for bacterial destruction. Plasma power, treatment time and needle-to-sample distance are varied. Plasma treatment of E. coli films results in formation of a bacteria-free void with a size up to 12 mm. 10{sup 4}-10{sup 5} colony forming units are already destroyed after 10 s of treatment. Prolongation of treatment time and usage of high powers do not significantly improve the destruction efficiency: short exposure at low plasma power is sufficient. Furthermore, we study the effects of temperature increase on the survival of E. coli and compare it with thermal effects of the plasma. The population of E. coli heated in a warm water bath starts to decrease at temperatures above 40 deg. C. Sample temperature during plasma treatment has been monitored. The temperature can reach up to 60 deg. C at high plasma powers and short needle-to-sample distances. However, thermal effects cannot account for bacterial destruction at low power conditions. For safe and efficient in vivo disinfection, the sample temperature should be kept low. Thus, plasma power and treatment time should not exceed 150 mW and 60 s, respectively.

  8. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  9. Effects of Rotational Motion in Robotic Needle Insertion

    Science.gov (United States)

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  10. Analysis of phytohormones and secondary plant products (main flavonoids and terpenes) in healthy and damaged needles from the natural location. Nachweis von Phytohormonen und sekundaeren Pflanzenstoffen (vor allem Flavonoiden und Terpenen) in gesunden und geschaedigten Nadeln vom natuerlichen Standort

    Energy Technology Data Exchange (ETDEWEB)

    Kraus, M [Technische Univ. Muenchen (Germany, F.R.). Inst. fuer Botanik und Mikrobiologie

    1989-07-01

    The determination of the phytohormone abscisic acid (ABA) in needles of fir (Abies alba Mill.) is difficult due to the small amount of ABA and the large volume of phenolic and terpenoic compounds, which have similar structures compared with ABA. The quantitative analysis of ABA in purified extracts was not possible by HPLC because of deficient separation. A qualified method for exact quantification is gas chromatography using an electron capture detector. In this way ABA was completely separated from all other substances. Starting from the question, whether the content of secondary plant products of needles of Picea abies (L.) Karst. is influenced by damage, spruces from Wank Mountain were analysed. The needle concentrations of different compounds were influenced significantly by the class of damage as well as by the level of altitude. (orig.).

  11. Insulin pen needles: effects of extra-thin wall needle technology on preference, confidence, and other patient ratings.

    Science.gov (United States)

    Aronson, Ronnie; Gibney, Michael A; Oza, Kunjal; Bérubé, Julie; Kassler-Taub, Kenneth; Hirsch, Laurence

    2013-07-01

    Pen needles (PNs) are essential for insulin injections using pen devices. PN characteristics affect patients' injection experience. The goal of this study was to evaluate the impact of a new extra-thin wall (XTW) PN versus usual PNs on overall patient preference, ease of injection, perceived time to complete the full dose, thumb button force to deliver the injection, and dose delivery confidence in individuals with diabetes mellitus (DM). Subjects injected insulin with the KwikPen(TM) (Eli Lilly and Company, Indianapolis, Indiana), SoloSTAR(®) (sanofi-aventis U.S. LLC, Bridgewater, New Jersey), and FlexPen(®) (Novo Nordisk A/S, Bagsvaerd, Denmark) insulin pens, and included some with impaired hand dexterity. We first performed quantitative testing of XTW and comparable PNs with the 3 insulin pens for thumb force, flow rate, and time to deliver medication. A prospective, randomized, 2-period, open-label, crossover trial was then conducted in patients aged 35 to 80 years with type 1 or type 2 DM who injected insulin by pen for ≥2 months, with at least 1 daily dose ≥10 U. Patients who used 4- to 8-mm length PNs with 31- to 32-G diameter were randomly assigned to use their current PN or the same/similar size XTW PN at home for ~1 week and the other PN the second week. They completed several comparative 150-mm visual analog scales and direct questions at the end of period 2. XTW PNs had statistically significant better performance for each studied PN characteristic (thumb force, flow, and time to deliver medication) for all pens combined and each individual pen brand (all, P ≤ 0.05). Of 216 patients randomized to study groups (80, SoloSTAR; 77, FlexPen; 59, KwikPen), 209 completed both periods; 198 were evaluable. Baseline characteristics revealed a mean (SD) age of 60.8 (9.3) years, insulin pen use duration of 4.3 (4.1) years, and mean total daily dose of 75.1 (52.3) U (range, 10-420 U). Approximately 50% of patients were female; 81.5% were white and 14.8% were

  12. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  13. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  14. Sit to stand in elderly fallers vs non-fallers: new insights from force platform and electromyography data.

    Science.gov (United States)

    Chorin, Frédéric; Cornu, Christophe; Beaune, Bruno; Frère, Julien; Rahmani, Abderrahmane

    2016-10-01

    The sit-to-stand movement requires balance control and coordination between the trunk and lower limbs. For these reasons, it is commonly used in clinics for evaluating lower limb muscle function in the elderly. The aim of the present study was to point out re levant biomechanical and neurophysiological sit-to-stand parameters allowing comparison between elderly fallers and non-fallers. Ten elderly fallers and thirty non-fallers performed sit-to-stand movements. Sit-to-stand mechanical (maximal and mean force, impulse) and temporal parameters were measured in the vertical and anteroposterior axes using force platforms. Activity of rectus femoris, vastus lateralis, and gastrocnemius lateralis muscles was bilaterally recorded by surface electromyography. Time to realize sit-to-stand movements was significantly longer in elderly fallers compared to non-fallers (p movement are the most relevant parameters to differentiate fallers and non-fallers. Moreover, these factors highlight different strategies to rise from a chair between faller and non-faller group, suggesting that fallers would constantly adjust their control balance during the sit-to-stand movement.

  15. Analysis of applied forces and electromyography of back and shoulders muscles when performing a simulated hand scaling task.

    Science.gov (United States)

    Porter, William; Gallagher, Sean; Torma-Krajewski, Janet

    2010-05-01

    Hand scaling is a physically demanding task responsible for numerous overexertion injuries in underground mining. Scaling requires the miner to use a long pry bar to remove loose rock, reducing the likelihood of rock fall injuries. The experiments described in this article simulated "rib" scaling (scaling a mine wall) from an elevated bucket to examine force generation and electromyographic responses using two types of scaling bars (steel and fiberglass-reinforced aluminum) at five target heights ranging from floor level to 176 cm. Ten male and six female subjects were tested in separate experiments. Peak and average force applied at the scaling bar tip and normalized electromyography (EMG) of the left and right pairs of the deltoid and erectores spinae muscles were obtained. Work height significantly affected peak prying force during scaling activities with highest force capacity at the lower levels. Bar type did not affect force generation. However, use of the lighter fiberglass bar required significantly more muscle activity to achieve the same force. Results of these studies suggest that miners scale points on the rock face that are below their knees, and reposition the bucket as often as necessary to do so. Published by Elsevier Ltd.

  16. Discrete vs. Continuous Mapping of Facial Electromyography for Human-Machine-Interface Control: Performance and Training Effects

    Science.gov (United States)

    Cler, Meredith J.; Stepp, Cara E.

    2015-01-01

    Individuals with high spinal cord injuries are unable to operate a keyboard and mouse with their hands. In this experiment, we compared two systems using surface electromyography (sEMG) recorded from facial muscles to control an onscreen keyboard to type five-letter words. Both systems used five sEMG sensors to capture muscle activity during five distinct facial gestures that were mapped to five cursor commands: move left, move right, move up, move down, and “click”. One system used a discrete movement and feedback algorithm in which the user produced one quick facial gesture, causing a corresponding discrete movement to an adjacent letter. The other system was continuously updated and allowed the user to control the cursor’s velocity by relative activation between different sEMG channels. Participants were trained on one system for four sessions on consecutive days, followed by one crossover session on the untrained system. Information transfer rates (ITRs) were high for both systems compared to other potential input modalities, both initially and with training (Session 1: 62.1 bits/min, Session 4: 105.1 bits/min). Users of the continuous system showed significantly higher ITRs than the discrete users. Future development will focus on improvements to both systems, which may offer differential advantages for users with various motor impairments. PMID:25616053

  17. Diagnostic accuracy of the electromyography parameters associated with anterior knee pain in the diagnosis of patellofemoral pain syndrome.

    Science.gov (United States)

    Ferrari, Deisi; Kuriki, Heloyse Uliam; Silva, Cristiano Rocha; Alves, Neri; Mícolis de Azevedo, Fábio

    2014-08-01

    To assess the diagnostic accuracy of the surface electromyography (sEMG) parameters associated with referred anterior knee pain in diagnosing patellofemoral pain syndrome (PFPS). Sensitivity and specificity analysis. Physical rehabilitation center and laboratory of biomechanics and motor control. Pain-free subjects (n=29) and participants with PFPS (n=22) selected by convenience. Not applicable. The diagnostic accuracy was calculated for sEMG parameters' reliability, precision, and ability to differentiate participants with and without PFPS. The selected sEMG parameter associated with anterior knee pain was considered as an index test and was compared with the reference standard for the diagnosis of PFPS. Intraclass correlation coefficient, SEM, independent t tests, sensitivity, specificity, negative and positive likelihood ratios, and negative and positive predictive values were used for the statistical analysis. The medium-frequency band (B2) parameter was reliable (intraclass correlation coefficient=.80-.90), precise (SEM=2.71-3.87 normalized unit), and able to differentiate participants with and without PFPS (Ppain showed positive diagnostic accuracy values (specificity, .87; sensitivity, .70; negative likelihood ratio, .33; positive likelihood ratio, 5.63; negative predictive value, .72; and positive predictive value, .86). The results provide evidence to support the use of EMG signals (B2-frequency band of 45-96 Hz) of the vastus lateralis and vastus medialis muscles with referred anterior knee pain in the diagnosis of PFPS. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Electromyography (EMG) signal recognition using combined discrete wavelet transform based adaptive neuro-fuzzy inference systems (ANFIS)

    Science.gov (United States)

    Arozi, Moh; Putri, Farika T.; Ariyanto, Mochammad; Khusnul Ari, M.; Munadi, Setiawan, Joga D.

    2017-01-01

    People with disabilities are increasing from year to year either due to congenital factors, sickness, accident factors and war. One form of disability is the case of interruptions of hand function. The condition requires and encourages the search for solutions in the form of creating an artificial hand with the ability as a human hand. The development of science in the field of neuroscience currently allows the use of electromyography (EMG) to control the motion of artificial prosthetic hand into the necessary use of EMG as an input signal to control artificial prosthetic hand. This study is the beginning of a significant research planned in the development of artificial prosthetic hand with EMG signal input. This initial research focused on the study of EMG signal recognition. Preliminary results show that the EMG signal recognition using combined discrete wavelet transform and Adaptive Neuro-Fuzzy Inference System (ANFIS) produces accuracy 98.3 % for training and 98.51% for testing. Thus the results can be used as an input signal for Simulink block diagram of a prosthetic hand that will be developed on next study. The research will proceed with the construction of artificial prosthetic hand along with Simulink program controlling and integrating everything into one system.

  19. Treatment Efficacy of Electromyography versus Fiberscopy-Guided Botulinum Toxin Injection in Adductor Spasmodic Dysphonia Patients: A Prospective Comparative Study

    Science.gov (United States)

    Kim, Jae Wook; Park, Jae Hong; Park, Ki Nam; Lee, Seung Won

    2014-01-01

    Introduction. This study prospectively evaluates and compares the treatment efficacy of botulinum toxin injection under electromyography guidance (EMG group) and percutaneous botulinum toxin injection under flexible fiberscopic guidance (fiberscopy group). Methods. Thirty patients with adductor spasmodic dysphonia (ADSD), who had never received treatment, were randomly allocated into EMG- or fiberscopy-guided botulinum toxin injections between March 2008 and February 2010. We assessed acoustic and aerodynamic voice parameters, and the voice handicap index (VHI) before injection and at 1, 3, and 6 months after injection. Results. The mean total dosage of botulinum toxin was similar for both groups: 1.7 ± 0.5 U for the EMG group and 1.8 ± 0.4 U for the fiberscopy group (P > 0.05). There were no significant differences in outcomes between the two groups in either the duration of effectiveness or complications such as breathy voice and aspiration. Conclusion. Botulinum toxin injection under fiberscopic guidance is a viable alternative to EMG-guided botulinum toxin injection for the treatment of adductor spasmodic dysphonia when EMG equipment is unavailable. PMID:25383369

  20. Cross-correlation of motor activity signals from dc-magnetoencephalography, near-infrared spectroscopy, and electromyography.

    Science.gov (United States)

    Sander, Tilmann H; Leistner, Stefanie; Wabnitz, Heidrun; Mackert, Bruno-Marcel; Macdonald, Rainer; Trahms, Lutz

    2010-01-01

    Neuronal and vascular responses due to finger movements were synchronously measured using dc-magnetoencephalography (dcMEG) and time-resolved near-infrared spectroscopy (trNIRS). The finger movements were monitored with electromyography (EMG). Cortical responses related to the finger movement sequence were extracted by independent component analysis from both the dcMEG and the trNIRS data. The temporal relations between EMG rate, dcMEG, and trNIRS responses were assessed pairwise using the cross-correlation function (CCF), which does not require epoch averaging. A positive lag on a scale of seconds was found for the maximum of the CCF between dcMEG and trNIRS. A zero lag is observed for the CCF between dcMEG and EMG. Additionally this CCF exhibits oscillations at the frequency of individual finger movements. These findings show that the dcMEG with a bandwidth up to 8 Hz records both slow and faster neuronal responses, whereas the vascular response is confirmed to change on a scale of seconds.

  1. Electromyography and vaginal pressure of the pelvic floor muscles in women with recurrent vulvovaginal candidiasis and vulvodynia.

    Science.gov (United States)

    Polpeta, Nádia Cristina; Giraldo, Paulo César; Juliato, Cássia Raquel Teatin; Yoshida, Laura Pagotto; do Amaral, Rose Luce Gomes; Eleutério, José

    2012-01-01

    To evaluate the electrical potentials and pressure exerted by the pelvic floor muscles in women with recurrent vulvovaginal candidiasis (RVVC) or vulvodynia as compared to control women. A cross-sectional study performed in the Female Outpatient Clinic of Genital Infections in the Department of Obstetrics and Gynecology of the Universidade Estadual de Campinas analyzed and compared electromyography (EMG) and vaginal pressure of the pelvic floor muscles in 61 women. Of these 61 women, 19 had vulvodynia, 12 had RVVC and 30 women had no disorder (control group). For data collection, the instrument used was the Miotool Uro device and its software Biotrainer (Miotec Ltd., Porto Alegre, Rio Grande do Sul, Brazil). The EMG evaluation of the pelvic floor muscles showed significantly lower values in the vulvodynia group (tonic contractions) and RVVC group (phasic and tonic contractions) when compared to the control group. No significant differences in basal tone EMG and vaginal pressure values at rest or during pelvic floor muscle contractions were found among groups. The maximum time of sustained contraction in patients with RVVC or vulvodynia was significantly lower (p < 0.0001) than in controls. Women with vulvodynia and RVVC have more frequent pelvic floor muscle dysfunction than controls when observed by EMG evaluation.

  2. Office-based Electromyography-guided Botulinum Toxin Injection to the Cricopharyngeus Muscle: Optimal Patient Selection and Technique.

    Science.gov (United States)

    Kim, Min-Su; Kim, Go-Woon; Rho, Young-Soo; Kwon, Kee-Hwan; Chung, Eun-Jae

    2017-05-01

    This retrospective study was carried out to investigate the effectiveness and safety of office-based electromyography-guided injection of botulinum toxin in the cricopharyngeus muscle of patients who did not show upper esophageal sphincter passage in a swallowing study in spite of maximal swallowing rehabilitation. Thirty-six patients who showed no or limited ability to oral feed after maximum swallowing rehabilitation were enrolled. Video fluoroscopic swallowing study, flexible endoscopic evaluation of swallowing, disability rating scale, penetration aspiration score, and National Institutes of Health swallowing safety scale were used in the evaluation of dysphagia. Success was defined as nondependence on gastrostomy for patients who previously were dependent on gastrostomy and improvement in disability rating scale score after botulinum toxin injections. The total success rate was 63.9%. The complication rate was very low, with only 1 patient showing temporary unilateral vocal fold paralysis. Botulinum toxin injection was more effective in patients with cranial nerve IX or X palsy than in those without it ( P = .006). This procedure can be a simple, safe, and effective tool in patients with cricopharyngeal dysfunction after swallowing rehabilitation, especially for cranial nerve IX or X palsy.

  3. Muscular Activities Measurements of Forward Lean and Upright Sitting Motorcycling Postures via Surface Electromyography (sEMG

    Directory of Open Access Journals (Sweden)

    Ma’arof Muhammad Izzat Nor

    2017-01-01

    Full Text Available Motorcycling postures are generically speculated to be physical and physiologically demanding – which in-turn may lead to motorcycling fatigue, and then becoming a possible factor to road accident. The objective of this study was to measure the muscular activities of various motorcycling postures. High muscular activity reading will signifies that motorcycling is indeed physically and physiologically demanding to the motorcyclist. For this particular study, the following postures were tested: i forward lean, ii upright sitting, and iii neutral sitting (as control. Surface electromyography (sEMG measurement was conducted on the following muscles: i extensor carpi radialis, ii upper trapezius iii latissimus dorsi, and iv erector spinae. The results showed that for all test subjects, the muscular activities readings for the forward lean posture was actually close to neutral sitting’s. Whilst, the upright sitting had showed much higher muscular activities measurement instead. Conclusively, this study had proven that any types of discomforts associated with the forward lean posture is not originated from muscular activities. Whereas, confirming that any discomforts in regards to the upright sitting is indeed related to muscular activities. Further studies are warranted to discover the actual risk factors that causes physical and physiological discomforts for the forward lean motorcycling posture.

  4. Is there any change in pelvic floor electromyography during the first 6 months after radical retropubic prostatectomy?

    Science.gov (United States)

    Hacad, Claudia R; Glazer, Howard I; Zambon, João Paulo C; Burti, Juliana S; Almeida, Fernando G

    2015-03-01

    The aim of this study is to determine electromyographic pelvic floor muscles activity during the first 6 months post RRP and its relationship to urinary continence. Thirty-eight men (mean age of 63.1 ± 5.7 year) with prostate cancer scheduled for open radical retropubic prostatectomy were evaluated. pelvic radiotherapy, systemic or neurologic diseases, pre-operative International Prostate Symptoms Score (IPSS) >7 and OABq ≥8. Surface electromyography (sEMG) evaluation, IPSS, Urinary Distress Inventory, Incontinence Impact Questionnaire, and Overactive Bladder Questionnaire-short form were applied before and at 1, 3, and 6 months after RRP. Six months after surgery, 18 men (47.4 %) presented urinary leakage. The sEMG evaluations within the first 6 months presented changes in fast contraction amplitude (p = 0.006), rest amplitude after fast contraction (p = 0.04), 10 s sustained contraction mean amplitude (p = 0.024) and final rest amplitude (p = 0.011). We observed that continent and incontinent patients as a group presented electromyographic changes during the first 6 months after radical prostatectomy that could be justified by the denervation/reinnervation of the external urethral sphincter. This finding is consistent with the adaptation of the pelvic floor musculature to the new urethral sphincter condition following surgery.

  5. Treatment Efficacy of Electromyography versus Fiberscopy-Guided Botulinum Toxin Injection in Adductor Spasmodic Dysphonia Patients: A Prospective Comparative Study

    Directory of Open Access Journals (Sweden)

    Jae Wook Kim

    2014-01-01

    Full Text Available Introduction. This study prospectively evaluates and compares the treatment efficacy of botulinum toxin injection under electromyography guidance (EMG group and percutaneous botulinum toxin injection under flexible fiberscopic guidance (fiberscopy group. Methods. Thirty patients with adductor spasmodic dysphonia (ADSD, who had never received treatment, were randomly allocated into EMG- or fiberscopy-guided botulinum toxin injections between March 2008 and February 2010. We assessed acoustic and aerodynamic voice parameters, and the voice handicap index (VHI before injection and at 1, 3, and 6 months after injection. Results. The mean total dosage of botulinum toxin was similar for both groups: 1.7 ± 0.5 U for the EMG group and 1.8 ± 0.4 U for the fiberscopy group (P>0.05. There were no significant differences in outcomes between the two groups in either the duration of effectiveness or complications such as breathy voice and aspiration. Conclusion. Botulinum toxin injection under fiberscopic guidance is a viable alternative to EMG-guided botulinum toxin injection for the treatment of adductor spasmodic dysphonia when EMG equipment is unavailable.

  6. Treatment efficacy of electromyography versus fiberscopy-guided botulinum toxin injection in adductor spasmodic dysphonia patients: a prospective comparative study.

    Science.gov (United States)

    Kim, Jae Wook; Park, Jae Hong; Park, Ki Nam; Lee, Seung Won

    2014-01-01

    This study prospectively evaluates and compares the treatment efficacy of botulinum toxin injection under electromyography guidance (EMG group) and percutaneous botulinum toxin injection under flexible fiberscopic guidance (fiberscopy group). Thirty patients with adductor spasmodic dysphonia (ADSD), who had never received treatment, were randomly allocated into EMG- or fiberscopy-guided botulinum toxin injections between March 2008 and February 2010. We assessed acoustic and aerodynamic voice parameters, and the voice handicap index (VHI) before injection and at 1, 3, and 6 months after injection. The mean total dosage of botulinum toxin was similar for both groups: 1.7 ± 0.5 U for the EMG group and 1.8 ± 0.4 U for the fiberscopy group (P > 0.05). There were no significant differences in outcomes between the two groups in either the duration of effectiveness or complications such as breathy voice and aspiration. Botulinum toxin injection under fiberscopic guidance is a viable alternative to EMG-guided botulinum toxin injection for the treatment of adductor spasmodic dysphonia when EMG equipment is unavailable.

  7. A MATLAB-based graphical user interface for the identification of muscular activations from surface electromyography signals.

    Science.gov (United States)

    Mengarelli, Alessandro; Cardarelli, Stefano; Verdini, Federica; Burattini, Laura; Fioretti, Sandro; Di Nardo, Francesco

    2016-08-01

    In this paper a graphical user interface (GUI) built in MATLAB® environment is presented. This interactive tool has been developed for the analysis of superficial electromyography (sEMG) signals and in particular for the assessment of the muscle activation time intervals. After the signal import, the tool performs a first analysis in a totally user independent way, providing a reliable computation of the muscular activation sequences. Furthermore, the user has the opportunity to modify each parameter of the on/off identification algorithm implemented in the presented tool. The presence of an user-friendly GUI allows the immediate evaluation of the effects that the modification of every single parameter has on the activation intervals recognition, through the real-time updating and visualization of the muscular activation/deactivation sequences. The possibility to accept the initial signal analysis or to modify the on/off identification with respect to each considered signal, with a real-time visual feedback, makes this GUI-based tool a valuable instrument in clinical, research applications and also in an educational perspective.

  8. Radio-frequency ablation in patients with malignant hepatic tumor and experimental model: comparison of expandable needle and water-cooled needle

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Yong Ju; Jeong, Yong Yeon; Kim, Jeong; Yim, Nam yeol; Kang, Heoung Keun [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of); Kim, Eun Ha; Yoon, Kwon Ha [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of); Ko, Seog Wan [School of Medicine, Chonbuk National Univ., Jeonju (Korea, Republic of)

    2004-12-01

    The purpose of this study was to compare the shape and volume of the radio-frequency induced lesions produced by two commercially available radio-frequency ablation (RFA) systems, the expandable and cooled-tip needles, in clinical patients and an experimental model. A twelve-array anchor expandable needle electrode and a single cooled-tip needle electrode were used to treat hepatic tumors with a single session in 23 patients (20 hepatocellular carcinomas and 3 hepatic metastases) and fourteen patients (10 hepatocellular carcinomas and 4 hepatic metastases), respectively. Twenty RFA induced lesions were created with each system in 10 explanted bovine livers. The shape of the RFA induced lesions were divided into oval lesions along or perpendicular to the axis of the electrode and spherical lesions, and we then calculated the volumes of the RFA induced lesions. Fourteen (61%) lesions of the 23 patients treated with the expandable system were oval perpendicular to the axis of the electrode and nine (39%) of the lesions were spherical. All the lesions (100%) of the 14 patients treated with the cooled-tip needle were ovaI along the axis of the electrode. In the ex vivo bovine livers, the shape of the all RFA induced lesions was oval perpendicular to the axis of the electrode for the expandable needle, and oval along the axis of the electrode for the cooled-tip needle. The mean diameter and volume of the RFA induced lesions in the patients were 3.35{+-}0.56 cm and 19.9{+-}6.53 cm{sup 3}, respectively, for the expandable needle and 3.58{+-}0.78 cm and 23.19{+-}5.27 cm{sup 3}, respectively, for the cooled-tip needle. In the ex vivo model, the mean diameter and volume of RFA induced lesions were 3.41{+-}0.59 cm and 26.59{+-}8.02 cm{sup 3}, respectively, for the expandable needle, and 4.04{+-}0.65 cm and 33.82{+-}6.16 cm{sup 3}, respectively, for the cooled-tip needle (p <0.05). These results indicate that the shape of RFA induced lesions with the expandable needle were oval

  9. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  10. The Problem of Metal Needles in Acupuncture-fMRI Studies

    Directory of Open Access Journals (Sweden)

    Florian Beissner

    2011-01-01

    Full Text Available Acupuncture is a therapy based on sensory stimulation of the human body by means of metal needles. The exact underlying mechanisms of acupuncture have not been clarified so far. Functional magnetic resonance imaging (fMRI has become an important tool in acupuncture research. Standard acupuncture needles, which are made of ferromagnetic steel, however, are problematic in acupuncture-fMRI studies for several reasons, such as attraction by the scanner's magnetic field, significant image distortions and signal-dropouts, when positioned close to the head or even heating due to absorption of radio frequency (RF. The aim of this study was to compare two novel types of acupuncture needles with a standard needle for their effect on MRI image quality. The standard needle severely reduced image quality, when located inside the RF coil. The nonferromagnetic metal needle may pose a risk due to RF heating, while the plastic needle has a significantly larger diameter. In conclusion, our recommendations are: (1 standard needles should not be used in MRI; (2 Nonferromagnetic metal needles seem to be the best choice for acupoints outside of the transmitter coil; and (3 only plastic needles are suited for points inside the coil. Laser acupuncture may be a safe alternative, too.

  11. Clinical observation of needle revision and 5-fluorouracil subconjunctive injection for the dysfunctional filtering blebs

    Directory of Open Access Journals (Sweden)

    Yan-Hua Gao

    2016-07-01

    Full Text Available AIM:To investigate the efficacy and safety of needle revision with 5-fluorouracil(5-FUon the dysfunctional filtering blebs after trabeculectomy and to assess the factors that may impact the success. METHODS:Eighty-three eyes in 76 patients underwent the needle revision and 5-FU subconjunctive injection for the dysfunctional blebs after trabeculectomy and were followed up for 12mo. The intraocular pressure(IOP, the number of drugs, corneal endothclium, bleb morphology and complications were observed and recorded. RESULTS:IOP decreased significantly from 35.3±5.8mmHg(1kPa=7.5mmHgof pre-needling to 17.0±4.3mmHg of post-needling(PPCI: 10.3-11.6. Statistically, there were no significant difference on needling effect with reference to the types of glaucoma, the use of mitomycin C(MMCduring the previous filtration surgery, the ages of patients, the intervals of needling operation from previous trabeculectomy, while there were significant difference on needling effect with reference to bleb appearance before needling, and the mean number of needling in patients that had surgery within 3mo were less than those who had surgery for more than 3mo. CONCLUSION: The needle revision combined with 5-FU is a safe, effective and simple method. Dysfunctional blebs should be treated early after trabeculectomy.

  12. Robust path planning for flexible needle insertion using Markov decision processes.

    Science.gov (United States)

    Tan, Xiaoyu; Yu, Pengqian; Lim, Kah-Bin; Chui, Chee-Kong

    2018-05-11

    Flexible needle has the potential to accurately navigate to a treatment region in the least invasive manner. We propose a new planning method using Markov decision processes (MDPs) for flexible needle navigation that can perform robust path planning and steering under the circumstance of complex tissue-needle interactions. This method enhances the robustness of flexible needle steering from three different perspectives. First, the method considers the problem caused by soft tissue deformation. The method then resolves the common needle penetration failure caused by patterns of targets, while the last solution addresses the uncertainty issues in flexible needle motion due to complex and unpredictable tissue-needle interaction. Computer simulation and phantom experimental results show that the proposed method can perform robust planning and generate a secure control policy for flexible needle steering. Compared with a traditional method using MDPs, the proposed method achieves higher accuracy and probability of success in avoiding obstacles under complicated and uncertain tissue-needle interactions. Future work will involve experiment with biological tissue in vivo. The proposed robust path planning method can securely steer flexible needle within soft phantom tissues and achieve high adaptability in computer simulation.

  13. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    International Nuclear Information System (INIS)

    Thompson, S.A.; Fung, A.Y.C.; Zaider, M.

    2002-01-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  14. NOTE: Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Science.gov (United States)

    Thompson, S. A.; Fung, A. Y. C.; Zaider, M.

    2002-08-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results.

  15. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.A. [Department of Medical Physics, North Shore-Long Island Jewish Health System, Manhassett, NY (United States); Fung, A.Y.C.; Zaider, M. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2002-08-21

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  16. Patients’ Knowledge of and Practices Relating to the Disposal of Used Insulin Needles

    Directory of Open Access Journals (Sweden)

    Kerri T. Musselman, PharmD

    2010-01-01

    Full Text Available Objective: To determine (1 how patients currently dispose of used insulin needles, (2 whether patients were educated about disposal of their used insulin needles, and (3 who educated patients about the disposal of their used insulin needles.Methods: A self-administered questionnaire was designed for this study. The survey assessed patient knowledge about disposal of used insulin needles and the patient-reported source and location of education about disposal techniques. The questionnaire was administered to a convenience sample of patients from four locations in Richmond, Virginia. Any patient who used insulin, was at least 18 years old, and was willing to complete the survey was eligible for inclusion.Results: Fifty responses were received with 40% indicating that education had been received on the disposal of used needles. From that 40%, nurses were identified as the source of education 60% of the time and pharmacists 25% of the time. Approximately 50% of the respondents reported disposing of used needles directly in the trash when at home. While away from home, 22% reported placing used needles in the trash, and 38% took them home for disposal.Conclusion: Patients are not consistently educated regarding the proper disposal of used needles. Health care practitioners should play a larger role in educating patients about the potential risks of inappropriate needle disposal and appropriate disposal methods. Future research is still needed to understand fully the magnitude of the problems associated with inappropriate needle disposal by patients.

  17. A climate response function explaining most of the variation in the forest floor needle mass and the needle decomposition in pine forests across Europe

    DEFF Research Database (Denmark)

    Kurz-Besson, C.; Coûteaux, M.M.; Berg, Bjørn

    2006-01-01

    The forest floor needle mass and the decomposition rates of pine needle litter in a European climate transect were studied in order to estimate the impact of climate change on forest soil carbon sequestration. Eight pine forests preserved from fire were selected along a climatic latitudinal...... gradient from 40° to 60° N, from Spain and Portugal to Sweden. The forest floor (Oi and Oe layers) was sorted into five categories of increasing decomposition level according to morphological criteria. The needle mass loss in each category was determined using a linear mass density method. The needle...... and a recalcitrant one. NF was correlated with actual evapotranspiration (AET) whereas the decomposition parameters (decomposition rate of the decomposable fraction, first year mass loss, forest floor needle mass, age of the most-decomposed category) were related to a combined response function to climate (CRF...

  18. Interactions of Cells with Magnetic Nanowires and Micro Needles

    KAUST Repository

    Perez, Jose E.

    2017-12-01

    The use of nanowires, nano and micro needles in biomedical applications has markedly increased in the past years, mainly due to attractive properties such as biocompatibility and simple fabrication. Specifically, these structures have shown promise in applications including cell separation, tumor cell capture, intracellular delivery, cell therapy, cancer treatment and as cell growth scaffolds. The work proposed here aims to study two platforms for different applications: a vertical magnetic nanowire array for mesenchymal stem cell differentiation and a micro needle platform for intracellular delivery. First, a thorough evaluation of the cytotoxicity of nanowires was done in order to understand how a biological system interacts with high aspect ratio structures. Nanowires were fabricated through pulsed electrodeposition and characterized by electron microscopy, vibrating sample magnetometry and energy dispersive X-ray spectroscopy. Studies of biocompatibility, cell death, cell membrane integrity, nanowire internalization and intracellular dissolution were all performed in order to characterize the cell response. Results showed a variable biocompatibility depending on nanowire concentration and incubation time, with cell death resulting from an apoptotic pathway arising after internalization. A vertical array of nanowires was then used as a scaffold for the differentiation of human mesenchymal stem cells. Using fluorescence and electron microscopy, the interactions between the dense array of nanowires and the cells were analyzed, as well as the biocompatibility of the array and its effects on cell differentiation. A magnetic field was additionally applied on the substrate to observe a possible differentiation. Stem cells grown on this scaffold showed a cytoskeleton and focal adhesion reorganization, and later expressed the osteogenic marker osteopontin. The application of a magnetic field counteracted this outcome. Lastly, a micro needle platform was fabricated

  19. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Science.gov (United States)

    Chesnel, Camille; Genêt, François; Almangour, Waleed; Denormandie, Philippe; Parratte, Bernard; Schnitzler, Alexis

    2015-01-01

    Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning) is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia. To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers. Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons) carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred. Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%): 4 (1%) in tendons or muscles, 3 (0.7%) in nerves and 1 (0.2%) in a vessel. This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  20. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hongming Song

    2015-01-01

    Full Text Available Background. Fine needle aspiration cytology (FNAC and fine needle nonaspiration cytology (FNNAC are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, Web of Science, Google Scholar, EBSCO, OALib, and the Cochrane Library databases. The following search terms were used: fine needle, aspiration, capillary, nonaspiration, sampling without aspiration, thyroid, and cytology. The last search was performed on February 1, 2015. Results. Sixteen studies comprising 1,842 patients and 2,221 samples were included in this study. No statistically significant difference was observed between FNAC and FNNAC groups with respect to diagnostically inadequate smears, diagnostically superior smears, diagnostic performance (accuracy, sensitivity, specificity, negative predictive value, and positive predictive value, area under the summary receiver operating characteristic curve, average score of each parameter (background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture, and total score of five parameters. Conclusion. FNAC and FNNAC are equally useful in assessing thyroid nodules.