WorldWideScience

Sample records for quality donor system

  1. Identification of the optimal donor quality scoring system and measure of early renal function in kidney transplantation.

    LENUS (Irish Health Repository)

    Moore, Jason

    2009-02-27

    The early identification of kidney allografts at risk of later dysfunction has implications for clinical practice. Donor quality scoring systems (preoperative) and measures of early allograft function (first week postoperative) have previously shown practical utility. This study aimed to determine the optimal parameter(s) (preoperative and postoperative) with greatest predictive power for the development of subsequent allograft dysfunction.

  2. Systems of donor transfer

    NARCIS (Netherlands)

    F.T. de Charro (Frank); J.E.M. Akveld (Hans); E. Hessing (Ellen)

    1993-01-01

    textabstractThe development of medical knowledge has resulted in a demand in society for donor organs, but the recruitment of donor organs for transplantation is difficult. This paper aims to provide some general insights into the complex interaction processes involved. A laissez-faire policy, in

  3. Quality of life of elderly live kidney donors.

    Science.gov (United States)

    Klop, Karel W J; Dols, Leonienke F C; Weimar, Willem; Dooper, Ine M; IJzermans, Jan N M; Kok, Niels F M

    2013-10-15

    Expanding the use of elderly live donors may help meet the demand for kidney transplants. The aim of this study was to quantify the effect of the surgical procedure on the quality of life (QOL) of elderly donors compared with younger donors. Alongside three prospective studies (two randomized) running between May 2001 and October 2010, we asked 501 live donors to fill out the Short Form-36 questionnaire preoperatively and at 1, 3, 6, and 12 months postoperatively. We defined live donors 60 years or older as elderly. Between-group analyses regarding QOL were adjusted for baseline values and gender. One hundred thirty-five donors were older and 366 donors were younger than 60 years. The response rate was high, with 87% at 12 months postoperatively. Elderly donors less often scored as American Society of Anaesthesiology classification 1 (60% vs. 81%; Pvitality" (5 points; P=0.008). At 3 months, "bodily pain" (3 points, P=0.04) and "role physical" (8 points, P=0.02) were still in favor of the older group. At 6 and 12 months, "physical function" was in favor of the younger group (3 and 5 points, respectively; P=0.04 and P<0.001). This study demonstrates that elderly donors recover relatively fast. The perspective of excellent postoperative QOL may help convince elderly individuals to donate.

  4. [Quality of life of living kidney donor: a national report].

    Science.gov (United States)

    Briançon, S; Germain, L; Baudelot, C; Bannay, A; Virion, J-M; Thuong, M

    2011-07-01

    The renal transplantation is nowadays the reference treatment of ESRD. Living donor kidney transplantation is less often performed in France than in other countries. Nevertheless, numerous French and international surveys have evidenced that it provides the recipients a longer life expectancy and a better quality of life. Donors themselves, what do they become? How are they? For the first time in France, a survey has been implemented to investigate the quality of life of living kidney donor to one of their close relations. This study has been undertaken by the Agency of the biomedecine and the service Clinical Epidemiology and Evaluation (EEC), of the University teaching hospital of Nancy. The main objective was to describe the quality of life of the living donors having given a kidney for more than a year and less than 5 years. The secondary objective was to contribute to the knowledge of the main factors associated to the living kidney donor quality of life, one year after the donation. Participants had to be living in France at the time of the donation which had taken place between June 30(th), 2005 and March 1(st), 2009. A folder gathering various self-administrated questionnaires was sent to the place of residence of the donor between March and April, 2010. These data were completed by medical data collected near the transplantation centres by the Agency of biomedecine within the framework of the register CRISTAL. They included the characteristics of the donation and of the donor at the very time of the donation, 3 months after the donation and at the last annual assessment. Three living donors in four, that is 501 persons, agreed to fully participate. They constituted a representative national sample of all the living donors of this period. The non participants were younger (4.5 years on average) and had a less adequate annual follow-up. The women were more represented (61 %) than men. The median age was 53 years. More of 2/3 were employed at the time of the

  5. Factors Determining Physical and Mental Quality of Life of Living Kidney Donors in Taiwan.

    Science.gov (United States)

    Chen, K-H; Yeh, L-C; Huang, H-L; Chiang, Y-J; Lin, M-H; Hsieh, C-Y; Weng, L-C

    2016-04-01

    Living-donor kidney transplantation has a positive influence on recipients' life expectancy and improves quality of life for patients with end-stage renal disease compared with dialysis patients. Evaluation of the physical and mental quality of life for donors can promote positive perceptions about donation and help potential donors in their decision-making process. The aim of this study was to explore the predictive factors of quality of life for living kidney donors. A cross-sectional and descriptive design was used, and the study was conducted from January to July 2013. The donors were a convenience sample of 34 participants who had undergone kidney transplant surgery >1 year earlier. The results showed that kidney donors had a low to moderate physical and mental quality of life. Multiple regression analysis revealed that financial concerns and anxiety explained 27.8% of the total variance of quality of life in the physical component. Anxiety and paid work explained 61.4% of the total variance of quality of life in the mental component. After renal transplantation, living kidney donors experienced low to moderate quality of life. Because donors are family members (siblings, sons or daughters, spouses, or parents), monthly family income is a significant issue that influences both the decision to donate and quality of life after transplantation. Our findings suggest that pre-transplantation assessment must include social workers as part of the health care team to evaluate the impact of a donor's financial status on post-transplantation quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Prospective, randomized, blinded evaluation of donor semen quality provided by seven commercial sperm banks.

    Science.gov (United States)

    Carrell, Douglas T; Cartmill, Deborah; Jones, Kirtly P; Hatasaka, Harry H; Peterson, C Matthew

    2002-07-01

    To evaluate variability in donor semen quality between seven commercial donor sperm banks, within sperm banks, and between intracervical insemination and intrauterine insemination. Prospective, randomized, blind evaluation of commercially available donor semen samples. An academic andrology laboratory. Seventy-five cryopreserved donor semen samples were evaluated. Samples were coded, then blindly evaluated for semen quality. Standard semen quality parameters, including concentration, motility parameters, World Health Organization criteria morphology, and strict criteria morphology. Significant differences were observed between donor semen banks for most semen quality parameters analyzed in intracervical insemination samples. In general, the greatest variability observed between banks was in percentage progressive sperm motility (range, 8.8 +/- 5.8 to 42.4 +/- 5.5) and normal sperm morphology (strict criteria; range, 10.1 +/- 3.3 to 26.6 +/- 4.7). Coefficients of variation within sperm banks were generally high. These data demonstrate the variability of donor semen quality provided by commercial sperm banks, both between banks and within a given bank. No relationship was observed between the size or type of sperm bank and the degree of variability. The data demonstrate the lack of uniformity in the criteria used to screen potential semen donors and emphasize the need for more stringent screening criteria and strict quality control in processing samples.

  7. Impact of a quality improvement project on deceased organ donor management

    Science.gov (United States)

    Olmos, Andrea; Feiner, John; Hirose, Ryutaro; Swain, Sharon; Blasi, Annabel; Roberts, John P.; Niemann, Claus U.

    2017-01-01

    Context Donors showed poor glucose control in the period between declaration of brain death and organ recovery. The level of hyperglycemia in the donors was associated with a decline in terminal renal function. Objective To determine whether implementation of a quality improvement project improved glucose control and preserved renal function in deceased organ donors. Methods Data collected retrospectively included demographics, medical history, mechanism of death, laboratory values, and data from the United Network for Organ Sharing. Results After implementation of the quality improvement project, deceased donors had significantly lower mean glucose concentrations (mean [SD], 162 [44] vs 212 [42] mg/dL; P donor cohorts from before and after the quality improvement project were analyzed together, mean glucose concentration remained a significant predictor of terminal creatinine level (P donors indicated that higher terminal creatinine level was associated with delayed graft function in recipients (P donor glucose homeostasis, and the data confirm that poor glucose homeostasis is associated with worsening terminal renal function. PMID:26645930

  8. Pediatric transplantation using hearts refused on the basis of donor quality.

    Science.gov (United States)

    Bailey, Leonard L; Razzouk, Anees J; Hasaniya, Nahidh W; Chinnock, Richard E

    2009-06-01

    There is always more demand than supply of organs in pediatric heart transplantation. Yet, potential donor organs are regularly declined for a variety of reasons, among them donor organ quality as determined by United Network for Organ Sharing (UNOS) refusal code 830 or its equivalent. For the study group institutional and UNOS databases (July 2000 to December 2008) were reviewed to examine outcomes of pediatric heart transplantation using donor hearts that had been previously refused one or more times because of organ quality. Variation between outcomes of this cohort and recipients who received primarily offered heart grafts in a single institution was analyzed. In 29 recipients, transplantation or retransplantation was with heart grafts previously declined on the basis of quality. Recovery distances (p actuarial survival was 74% +/- 10.5%. At the present time, 24 of the 29 recipients (83%) are alive. These results do not vary statistically from those experienced by 84 recipients of 86 primarily offered donor organs during the same time. Despite longer distance recovery (ie, longer graft cold ischemic times), outcomes of pediatric heart transplantation using donor heart grafts refused on the basis of organ quality are highly competitive. Pediatric donor hearts should seldom be declined on the basis of organ quality (UNOS code 830).

  9. CT for evaluation of potential renal donors – How does iterative reconstruction influence image quality and dose?

    Energy Technology Data Exchange (ETDEWEB)

    Kahn, Johannes, E-mail: johannes.kahn@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Grupp, Ulrich, E-mail: ulrich.grupp@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Rotzinger, Roman, E-mail: roman.rotzinger@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Kaul, David, E-mail: david.kaul@charite.de [Department of Radiooncology and Radiotherapy, Charité, Charitéplatz 1, 10117 Berlin (Germany); Schäfer, Max-Ludwig, E-mail: max-ludwig.schaefer@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany); Streitparth, Florian, E-mail: florian.streitparth@charite.de [Department of Radiology, Charité, Charitéplatz 1, 10117 Berlin (Germany)

    2014-08-15

    Purpose: To assess ASIR (adaptive statistical iterative reconstruction) technique regarding dose reduction and its impact on image quality in evaluation CTs of potential kidney donors. Materials and methods: Between May and November 2013, a prospective study of 53 assumingly healthy potential kidney donors was conducted. The subjects underwent abdominal evaluation CT prior to the planned explantation of a kidney and were randomly divided into 2 groups: Group A was examined with an ASIR 40 protocol (n = 26), group B (n = 27) was examined using a standard FBP (filtered back projection) protocol. Image quality was assessed both quantitatively (by obtaining attenuation values in different organ regions and calculating SNR and CNRs) and qualitatively (by two observers who evaluated image quality using a 5-point scale system). Applied dose was analyzed as CTDIvol (mGy), total DLP (mGy × cm) and effective dose (mSv). Results: Applied dose in group A was about 26% lower than in group B (p < 0.05). Between both groups, dose determining parameters such as scan length and patients’ body diameter showed no significant difference. SNR (signal-to-noise ratio) was significantly higher in group A (p < 0.05). CNRs (contrast-to-noise ratios) for different tissues were not significantly different. Observer rated image quality showed no significant difference. Conclusion: ASIR can contribute to a relevant dose reduction without any loss of image quality in CT scans for evaluating potential kidney donors.

  10. Decline of semen quality among Chinese sperm bank donors within 7 years (2008-2014

    Directory of Open Access Journals (Sweden)

    Li Wang

    2017-01-01

    Full Text Available Semen from 5210 sperm bank donors was analyzed and trends in semen quality were evaluated at Shandong Human Sperm Bank between 2008 and 2014. After 2-7 days of abstinence, semen samples were collected. Measurements of semen volume, sperm concentration, sperm forward motility, and total sperm count were performed. There were significant declining trends in semen volume, sperm concentration, sperm forward motility, and total sperm count. Our results indicate that the quality of semen in this cohort of sperm donors had decreased during the study period.

  11. Quality management system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mu Sung

    2009-08-15

    This book deals with ISO9001 quality management system which includes summary of this system such as classification of quality, principle of quality management, and definition, requirement and procedure of quality management system, introduction of ISO9001 system like model of ISO9001 quality management system, ISO certificate system, structure of ISO9001 standard, requirement of ISO9001 quality management system, process approach and documentation of system, propel cases of ISO9001 quality management system.

  12. Quality management system

    International Nuclear Information System (INIS)

    Lee, Mu Sung

    2009-08-01

    This book deals with ISO9001 quality management system which includes summary of this system such as classification of quality, principle of quality management, and definition, requirement and procedure of quality management system, introduction of ISO9001 system like model of ISO9001 quality management system, ISO certificate system, structure of ISO9001 standard, requirement of ISO9001 quality management system, process approach and documentation of system, propel cases of ISO9001 quality management system.

  13. Informed consent in research to improve the number and quality of deceased donor organs.

    Science.gov (United States)

    Rey, Michael M; Ware, Lorraine B; Matthay, Michael A; Bernard, Gordon R; McGuire, Amy L; Caplan, Arthur L; Halpern, Scott D

    2011-02-01

    Improving the management of potential organ donors in the intensive care unit could meet an important public health goal by increasing the number and quality of transplantable organs. However, randomized clinical trials are needed to quantify the extent to which specific interventions might enhance organ recovery and outcomes among transplant recipients. Among several barriers to conducting such studies are the absence of guidelines for obtaining informed consent for such studies and the fact that deceased organ donors are not covered by extant federal regulations governing oversight of research with human subjects. This article explores the underexamined ethical issues that arise in the context of donor management studies and provides ethical guidelines and suggested regulatory oversight mechanisms to enable such studies to be conducted ethically. We conclude that both the respect that is traditionally accorded to the prior wishes of the dead and the possibility of postmortem harm support a role for surrogate consent of donors in such randomized controlled trials. Furthermore, although recipients will often be considered human subjects under federal regulations, several ethical arguments support waiving requirements for recipient consent in donor management randomized controlled trials. Finally, we suggest that new regulatory mechanisms, perhaps linked to existing regional and national organ donation and transplantation infrastructures, must be established to protect patients in donor management studies while limiting unnecessary barriers to the conduct of this important research.

  14. Ultrafast Photoinduced Electron Transfer in Bimolecular Donor-Acceptor Systems

    KAUST Repository

    Alsulami, Qana A.

    2016-11-30

    The efficiency of photoconversion systems, such as organic photovoltaic (OPV) cells, is largely controlled by a series of fundamental photophysical processes occurring at the interface before carrier collection. A profound understanding of ultrafast interfacial charge transfer (CT), charge separation (CS), and charge recombination (CR) is the key determinant to improving the overall performances of photovoltaic devices. The discussion in this dissertation primarily focuses on the relevant parameters that are involved in photon absorption, exciton separation, carrier transport, carrier recombination and carrier collection in organic photovoltaic devices. A combination of steady-state and femtosecond broadband transient spectroscopies was used to investigate the photoinduced charge carrier dynamics in various donor-acceptor systems. Furthermore, this study was extended to investigate some important factors that influence charge transfer in donor-acceptor systems, such as the morphology, energy band alignment, electronic properties and chemical structure. Interestingly, clear correlations among the steady-state measurements, time-resolved spectroscopy results, grain alignment of the electron transporting layer (ETL), carrier mobility, and device performance are found. In this thesis, we explored the significant impacts of ultrafast charge separation and charge recombination at donor/acceptor (D/A) interfaces on the performance of a conjugated polymer PTB7-Th device with three fullerene acceptors: PC71BM, PC61BM and IC60BA. Time-resolved laser spectroscopy and high-resolution electron microscopy can illustrate the basis for fabricating solar cell devices with improved performances. In addition, we studied the effects of the incorporation of heavy metals into π-conjugated chromophores on electron transfer by monitoring the triplet state lifetime of the oligomer using transient absorption spectroscopy, as understanding the mechanisms controlling intersystem crossing and

  15. Assessing Pearl Quality Using Reflectance UV-Vis Spectroscopy: Does the Same Donor Produce Consistent Pearl Quality?

    Directory of Open Access Journals (Sweden)

    Paul C. Southgate

    2010-09-01

    Full Text Available Two groups of commercial quality (“acceptable” pearls produced using two donors, and a group of “acceptable” pearls from other donors were analyzed using reflectance UV-Vis spectrophotometry. Three pearls with different colors produced by the same donor showed different absorption spectra. Cream and gold colored pearls showed a wide absorption from 320 to about 460 nm, while there was just slight reflectance around 400 nm by the white pearl with a pink overtone. Cream and gold pearls reached a reflectance peak at 560 to 590 nm, while the white pearl with pink overtone showed slightly wider absorption in this region. Both cream and gold pearls showed an absorption peak after the reflectance peak, at about 700 nm for the cream pearl and 750 nm for the gold pearl. Two other pearls produced by the same donor (white with cream overtone and cream with various overtones showed similar spectra, which differed in their intensity. One of these pearls had very high lustre and its spectrum showed a much higher percentage reflectance than the second pearl with inferior lustre. This result may indicate that reflectance is a useful quantitative indicator of pearl lustre. The spectra of two white pearls resulting from different donors with the same color nacre (silver showed a reflectance at 260 nm, followed by absorption at 280 nm and another reflectance peak at 340 nm. After this peak the spectra for these pearls remained flat until a slight absorption peak around 700 nm. Throughout the visible region, all white pearls used in this study showed similar reflectance spectra although there were differences in reflectance intensity. Unlike the spectral results from white pearls, the results from yellow and gold pearls varied according to color saturation of the pearl. The results of this study show that similarities between absorption and reflectance spectra of cultured pearls resulting from the same saibo donor are negligible and could not be detected

  16. Qualidade de vida do doador após transplante hepático intervivos Donor quality of life after living donor liver transplantation

    Directory of Open Access Journals (Sweden)

    Júlio Cezar Uili Coelho

    2005-06-01

    Full Text Available RACIONAL: A qualidade de vida do doador após transplante hepático intervivos ainda não foi avaliada em nosso meio. OBJETIVO: Avaliar a qualidade de vida do doador após transplante hepático intervivos. MÉTODOS: De um total de 300 transplantes hepáticos, 51 foram de doadores vivos. Doadores com seguimento menor do que 6 meses e os que não quiseram participar do estudo foram excluídos. Os doadores responderam a um questionário de 28 perguntas abordando os vários aspectos da doação, sendo também avaliados dados demográficos e clínicos dos mesmos. RESULTADOS: Trinta e sete doadores aceitaram participar do estudo. Destes, 32 eram parentes de primeiro ou de segundo grau do receptor. O esclarecimento sobre o caráter voluntário da doação foi adequado para todos pacientes. Apenas um (2% não doaria novamente. A dor pós-operatória foi pior do que o esperado para 22 doadores (59%. O retorno às atividades normais ocorreu em menos de 3 meses para 21 doadores (57%. Vinte e um doadores (57% tiveram perda financeira com a doação devido a gastos com medicamentos, exames, transporte ou perda de rendimentos. Trinta e três (89% não tiveram modificação ou limitação na sua vida após a doação. Os aspectos mais negativos da doação foram a dor pós-operatória e a presença de cicatriz cirúrgica. A maioria das complicações pós-operatória foi resolvida com o tratamento clínico, mas complicações graves ou potencialmente fatais ocorreram em dois pacientes. CONCLUSÕES: A maioria dos doadores apresentou boa recuperação e retornou completamente as suas atividades normais poucos meses após a doação. O aspecto mais negativo da doação foi a dor pós-operatória.BACKGROUND: Quality of life of the donor after living donor liver transplantation has not been evaluated in Brazil yet. AIM: To evaluate the quality of live of the donor after living donor liver transplantation. METHODS: Of a total of 300 liver transplantations, 51 were

  17. Interactions of donor sources and media influence the histo-morphological quality of full-thickness skin models.

    Science.gov (United States)

    Lange, Julia; Weil, Frederik; Riegler, Christoph; Groeber, Florian; Rebhan, Silke; Kurdyn, Szymon; Alb, Miriam; Kneitz, Hermann; Gelbrich, Götz; Walles, Heike; Mielke, Stephan

    2016-10-01

    Human artificial skin models are increasingly employed as non-animal test platforms for research and medical purposes. However, the overall histopathological quality of such models may vary significantly. Therefore, the effects of manufacturing protocols and donor sources on the quality of skin models built-up from fibroblasts and keratinocytes derived from juvenile foreskins is studied. Histo-morphological parameters such as epidermal thickness, number of epidermal cell layers, dermal thickness, dermo-epidermal adhesion and absence of cellular nuclei in the corneal layer are obtained and scored accordingly. In total, 144 full-thickness skin models derived from 16 different donors, built-up in triplicates using three different culture conditions were successfully generated. In univariate analysis both media and donor age affected the quality of skin models significantly. Both parameters remained statistically significant in multivariate analyses. Performing general linear model analyses we could show that individual medium-donor-interactions influence the quality. These observations suggest that the optimal choice of media may differ from donor to donor and coincides with findings where significant inter-individual variations of growth rates in keratinocytes and fibroblasts have been described. Thus, the consideration of individual medium-donor-interactions may improve the overall quality of human organ models thereby forming a reproducible test platform for sophisticated clinical research. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Spectrophotometric investigation into iodine-electron donor systems at low temperature

    International Nuclear Information System (INIS)

    Gorodyskij, V.A.; Morachevskij, A.A.

    1978-01-01

    Iodine-sec. butanol (n-donor) and iodine - hexene - 1 (π-donor) have been investigated for the first time by the spectrophotometric method in the wide temeprature range (77-293 K). The existence of complexes with a charge transfer of the type, which is characterized by the long-wave absorption band in electron spectra, is determined in the systems

  19. Conformational dynamics of semiflexibly bridged electron donor-acceptor systems comprising long aliphatic tails

    NARCIS (Netherlands)

    Bleisteiner, B.; Marian, T.; Schneider, S.; Brouwer, A.M.; Verhoeven, J.W.

    2001-01-01

    In continuation of our previous work on the conformational dynamics (harpooning mechanism) of semiflexibly bridged electron donor-acceptor systems we have studied a derivative with two long aliphatic chains tethered to the donor and acceptor moieties, respectively. The fitting of the time- and

  20. Quality data systems

    International Nuclear Information System (INIS)

    Bergman, J.E.; Patterson, R.G.

    1976-01-01

    General Electric's Nuclear Fuel Department data system strategy of multifunctional system integration and specific applications of data systems for the Quality Assurance Programme is detailed. Descriptions of two manufacturing control systems and their function in satisfying quality data requirements are included. The timesharing quality data system developed for processing laboratory, traceability and material release data in the Fuel Manufacturing Operation is described. In addition, specific references are made to those areas where significant time reductions have been realized through the utilization of mechanized data-handling systems. (author)

  1. Donor support for quality assurance and pharmacovigilance of anti-malarials in malaria-endemic countries.

    Science.gov (United States)

    Kovacs, Stephanie D; Mills, Brianna M; Stergachis, Andy

    2017-07-11

    Malaria control efforts have been strengthened by funding from donor groups and government agencies. The Global Fund to Fight AIDS, Tuberculosis and the Malaria (Global Fund), the US President's Malaria Initiative (PMI) account for the majority of donor support for malaria control and prevention efforts. Pharmacovigilance (PV), which encompasses all activities relating to the detection, assessment, understanding, and prevention of adverse effects or any other drug-related problem, is a necessary part of efforts to reduce drug resistance and improve treatment outcomes. This paper reports on an analysis of PV plans in the Global Fund and PMI and World Bank's grants for malaria prevention and control. All active malaria grants as of September 2015 funded by the Global Fund and World Bank, and fiscal year 2015 and 2016 PMI Malaria Operational Plans (MOP) were identified. The total amount awarded for PV-related activities and drug quality assurance was abstracted. A Key-Word-in-Context (KWIC) analysis was conducted for the content of each grant. Specific search terms consisted of pharmacovigilance, pregn*, registry, safety, adverse drug, mass drug administration, primaquine, counterfeit, sub-standard, and falsified. Grants that mentioned PV activities identified in the KWIC search, listed PV in their budgets, or included the keywords: counterfeit, sub-standard, falsified, mass drug administration, or adverse event were thematically coded using Dedoose software version 7.0. The search identified 159 active malaria grants including 107 Global Fund grants, 39 fiscal year 2015 and 2016 PMI grants and 13 World Bank grants. These grants were primarily awarded to low-income countries (57.2%) and in sub-Saharan Africa (SSA) (70.4%). Thirty-seven (23.3%) grants included a budget line for PV- or drug quality assurance-related activities, including 21 PMI grants and 16 Global Fund grants. Only 23 (14.5%) grants directly mentioned PV. The primary focus area was improving drug

  2. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    Directory of Open Access Journals (Sweden)

    Diana Escuder-Vieco

    2018-05-01

    Full Text Available Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min. Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L. In conclusion, processing of donor milk at 72°C for at least 10 s in

  3. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting.

    Science.gov (United States)

    Escuder-Vieco, Diana; Espinosa-Martos, Irene; Rodríguez, Juan M; Corzo, Nieves; Montilla, Antonia; Siegfried, Pablo; Pallás-Alonso, Carmen R; Fernández, Leónides

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination) processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L). In conclusion, processing of donor milk at 72°C for at least 10 s in this HTST system

  4. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    Science.gov (United States)

    Escuder-Vieco, Diana; Espinosa-Martos, Irene; Rodríguez, Juan M.; Corzo, Nieves; Montilla, Antonia; Siegfried, Pablo; Pallás-Alonso, Carmen R.; Fernández, Leónides

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an alternative for a better preservation of some of the biological components of human milk although, at present, there is no equipment available to perform this treatment under the current conditions of a human milk bank. In this work, the specific needs of a human milk bank setting were considered to design an HTST equipment for the continuous and adaptable (time-temperature combination) processing of donor milk. Microbiological quality, activity of indicator enzymes and indices for thermal damage of milk were evaluated before and after HTST treatment of 14 batches of donor milk using different temperature and time combinations and compared to the results obtained after Holder pasteurization. The HTST system has accurate and simple operation, allows the pasteurization of variable amounts of donor milk and reduces processing time and labor force. HTST processing at 72°C for, at least, 10 s efficiently destroyed all vegetative forms of microorganisms present initially in raw donor milk although sporulated Bacillus sp. survived this treatment. Alkaline phosphatase was completely destroyed after HTST processing at 72 and 75°C, but γ-glutamil transpeptidase showed higher thermoresistance. Furosine concentrations in HTST-treated donor milk were lower than after Holder pasteurization and lactulose content for HTST-treated donor milk was below the detection limit of analytical method (10 mg/L). In conclusion, processing of donor milk at 72°C for at least 10 s in this HTST system

  5. Advising potential recipients on the use of organs from donors with primary central nervous system tumors.

    Science.gov (United States)

    Warrens, Anthony N; Birch, Rhiannon; Collett, David; Daraktchiev, Maren; Dark, John H; Galea, George; Gronow, Katie; Neuberger, James; Hilton, David; Whittle, Ian R; Watson, Christopher J E

    2012-02-27

    Deciding to use an organ from a donor with a primary central nervous system (CNS) tumor necessitates offsetting the risk of tumor transmission with the chances of survival if the patient waits for another offer of a transplant. Published data vary in the quoted risk of tumor transmission. We used data obtained by reviewing 246 UK recipients of organs taken from donors with CNS tumors and found no evidence of a difference in overall patient mortality for recipients of a kidney, liver, or cardiothoracic organ, compared with recipients of organs from donors without a CNS tumor. Recent publication of the UK experience of transplanting organs from CNS tumor donors found no transmission in 448 recipients of organs from 177 donors with a primary CNS tumor (Watson et al., Am J Transplant 2010; 10: 1437). This 0% transmission rate is associated with an upper 95% confidence interval limit of 1.5%. Using a series of assumptions of risk, we compared the risks of dying as a result of the transmission of a primary brain tumor with the risks of dying if not transplanted. On this basis, the use of kidneys from a donor with a primary CNS tumor provides a further 8 years of life over someone who waited for a donor who did not have a primary CNS tumor, in addition to the life years gained by the transplant itself. The benefits for the recipients of livers and cardiothoracic organs were less, but there was no disadvantage in the impact on life expectancy.

  6. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    OpenAIRE

    F. Majlessi; S. Ghafari; A. Rahimi-Foroushani M. Maghsoodlou

    2008-01-01

    The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sec...

  7. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    Directory of Open Access Journals (Sweden)

    F. Majlessi

    2008-06-01

    Full Text Available The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sectional study was performed on 554 blood donors who had donated blood from February 2005 through September 2005 in four fixed blood donation bases and four mobile blood collection buses. Each base was considered as a stratum, and a stratified random sampling proportional to size was done to select the donors. Results showed donor reaction rate to be 13.4%, the most common of which were blackout of vision (7%, dizziness (6.3%, fatigue (6.1% and nausea (1.8%. There was no significant relationship between the incidence of these complications and type of base blood donation or fasting at the time of blood donation. Logistic Regression analysis showed that sex, condition of blood donor, exercise or walking, duration of donation, and practice to recommendation had significant effects on the odds ratio of systemic complication. Regarding the frequency values derived for the different systemic complications it can be concluded that attention to risk factors of these complications and their control can help encourage donors to become repeated donors as well as to prevent their withdrawal for further blood donation.

  8. Nanographenes as electron-deficient cores of donor-acceptor systems.

    Science.gov (United States)

    Liu, Yu-Min; Hou, Hao; Zhou, Yan-Zhen; Zhao, Xin-Jing; Tang, Chun; Tan, Yuan-Zhi; Müllen, Klaus

    2018-05-15

    Conjugation of nanographenes (NGs) with electro-active molecules can establish donor-acceptor π-systems in which the former generally serve as the electron-donating moieties due to their electronic-rich nature. In contrast, here we report a series of reversed donor-acceptor structures are obtained by C-N coupling of electron-deficient perchlorinated NGs with electron-rich anilines. Selective amination at the vertexes of the NGs is unambiguously shown through X-ray crystallography. By varying the donating ability of the anilino groups, the optical and assembly properties of donor-acceptor NGs can be finely modulated. The electron-deficient concave core of the resulting conjugates can host electron-rich guest molecules by intermolecular donor-acceptor interactions and gives rise to charge-transfer supramolecular architectures.

  9. CNEA's quality system documentation

    International Nuclear Information System (INIS)

    Mazzini, M.M.; Garonis, O.H.

    1998-01-01

    Full text: To obtain an effective and coherent documentation system suitable for CNEA's Quality Management Program, we decided to organize the CNEA's quality documentation with : a- Level 1. Quality manual. b- Level 2. Procedures. c-Level 3. Qualities plans. d- Level 4: Instructions. e- Level 5. Records and other documents. The objective of this work is to present a standardization of the documentation of the CNEA's quality system of facilities, laboratories, services, and R and D activities. Considering the diversity of criteria and formats for elaboration the documentation by different departments, and since ultimately each of them generally includes the same quality management policy, we proposed the elaboration of a system in order to improve the documentation, avoiding unnecessary time wasting and costs. This will aloud each sector to focus on their specific documentation. The quality manuals of the atomic centers fulfill the rule 3.6.1 of the Nuclear Regulatory Authority, and the Safety Series 50-C/SG-Q of the International Atomic Energy Agency. They are designed by groups of competent and highly trained people of different departments. The normative procedures are elaborated with the same methodology as the quality manuals. The quality plans which describe the organizational structure of working group and the appropriate documentation, will asses the quality manuals of facilities, laboratories, services, and research and development activities of atomic centers. The responsibilities for approval of the normative documentation are assigned to the management in charge of the administration of economic and human resources in order to fulfill the institutional objectives. Another improvement aimed to eliminate unnecessary invaluable processes is the inclusion of all quality system's normative documentation in the CNEA intranet. (author) [es

  10. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  11. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  12. Changes in the organ procurement system in South Korea: effects on brain-dead donor numbers.

    Science.gov (United States)

    Lee, S D; Kim, J H

    2009-11-01

    In Korea, the Organ Transplantation Act came into effect in 2000, establishing the Korean Network for Organ Sharing (KONOS) with centralized authority for organ procurement as well as for approval of donors and recipients to ensure fair organ allocation. However, the number of brain-dead donors decreased sharply, and the organ allocation system proved inefficient. The government revised the Organ Transplantation Act in August 2002, introducing an incentive system. If a transplantation hospital formed a Committee for Brain Death Evaluation and a Hospital Organ Procurement Organization, it could receive a kidney from a brain dead-donor as an incentive to foster organ procurement regardless of the KONOS wait list. The government also launched a pilot brain-dead donor registry program to strengthen Hospital Organ Procurement Organization activity. If local hospitals collaborated with specialized hospitals in organ procurement, local hospitals obtained financial incentives. But because the organ shortage problem has not been resolved, the government has proposed four initiatives: first, broadening the incentive system, which makes it possible to give each specialized hospital a choice of one of eight organs from each donor as an incentive; second, development of an Independent Organ Procurement Organization; third introduction of an opt-out system; and last, improvement of the Committee for Brain Death Evaluation system. It is uncertain which initiatives will be adopted, but changes in organ procurement systems are nonetheless considered a key to solve the organ shortage problem in Korea.

  13. Quality education as quality system support

    International Nuclear Information System (INIS)

    Crnoshia, L.; Gavriloska, M.; Denkovska, J.; Dimitrovski, A.

    1999-01-01

    Within the last ten years we are witnesses of the political and economical system transformation, that imposed the need for changing the way of thinking and work planning. The quality has become the imperative of working and a precondition for survival in the market. Solving the quality problems seeks planned and systematic approach that supposed appropriate personnel with adequate knowledge in the field of quality management and implementation of the quality system. Having in mind the need for documented quality system and quality management OKTA, has already started with personnel educational process for quality as a precondition for successful establishment of quality system. In this paper we present quality education approach and manner of its realization in OKTA Crude Oil Refinery - Skopje, Macedonia. (Original)

  14. The Quality System

    DEFF Research Database (Denmark)

    Brogaard Buus, Daniel; Eland, Morten Vestergaard; Lystlund, Rasmus

    2015-01-01

    In this article, we present our efforts to try to increase cohesiveness and connectivity between quests generated by a recreation of an existing procedural quest generation system, with an addition of a progressive tier system called Quality System. A study gave strong indications that the Qualit...... System successfully produced a positive effect on the feeling of cohesiveness and connectivity between the generated quests amongst Role-playing- and Massively Multiplayer Online games players....

  15. [Effect of nutritional status of the donor on the quality of hepatic graft. Value of restoration of glycogenic reserves of the donor].

    Science.gov (United States)

    Pattou, F; Boudjema, K; Kerr-Conte, J; Wolf, P; Jaeck, D; Cinqualbre, J

    1992-01-01

    Initial function of the graft is an essential factor for successful liver transplantation. The aim of this study was to evaluate the influence of the nutritional status of the donor on hepatic graft quality at reperfusion. Livers (n = 41) were taken from pigs normally fed or fasted for 24 h or fasted for 24 h and conditioned for 2 hours with a solution containing glucose, fructose and glutamine. The quality of liver grafts was evaluated using an original, blood-free isolated perfusion model, after 8 h cold storage, or after 15 min warm ischemia performed prior to harvesting. The hepatic concentration of glycogen and ATP, measured from in vivo biopsies, was decreased in fasted animals (P less than 0.05 vs fed) and restored by nutritional conditioning (P less than 0.05 vs fasted). At the time of reperfusion following 8 h cold ischemia, the liberation of aminotransferases and lactate dehydrogenase was elevated in livers coming from fasted animals (P less than 0.05 vs fed) and restored to fed levels after nutritional conditioning (P less than 0.01 vs fasted). After 15 min of warm ischemia, the bile secretion during the reperfusion period was decreased in the 24 h fasted livers (P less than 0.01 vs fed) and reestablished after nutritional conditioning (P less than 0.01 vs fasted). Perfusion of the donor liver, in the 2 h preceding harvest, with a solution of glucose plus neoglucogenic precursors enhances the quality of the liver graft at the time of reperfusion.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Quality of harvested autologous platelets compared with stored donor platelets for use after cardiopulmonary bypass procedures.

    Science.gov (United States)

    Crowther, M; Ford, I; Jeffrey, R R; Urbaniak, S J; Greaves, M

    2000-10-01

    Platelet dysfunction has a major contribution in bleeding after cardiopulmonary bypass (CPB) and transfusion of platelets is frequently used to secure haemostasis. Allogeneic platelets prepared for transfusion are functionally impaired. Autologous platelets harvested preoperatively require a shorter storage time before transfusion and their use also avoids the risks associated with transfusion of allogeneic blood products. For the first time, we have compared the functional quality of autologous platelets with allogeneic platelets prepared by two methods, immediately before infusion. Platelet activation was assessed by P-selectin expression and fibrinogen binding using flow cytometry. We also monitored the effects of CPB surgery and re-infusion of autologous platelets on platelet function. Autologous platelet-rich plasma (PRP) contained a significantly lower (P platelets compared with allogeneic platelet preparations, and also contained a significantly higher (P platelets. Allogeneic platelets prepared by donor apheresis were more activated and less responsive than those produced by centrifugation of whole blood. In patients' blood, the percentage of platelets expressing P-selectin or binding fibrinogen increased significantly after CPB (P platelets responsive to in vitro agonists was decreased (P platelet activation during the procedure. The percentage of activated platelets decreased (statistically not significant) after re-infusion of autologous PRP. P-selectin expression had returned to pre-CPB levels 24 h post-operatively. Autologous platelet preparations display minimal activation, but remain responsive. Conservation of platelet function may contribute to the potential clinical benefits of autologous transfusion in cardiopulmonary bypass.

  17. Photochromic and electrochromic performances of new types of donor/acceptor systems based on crosslinked polyviologen film and electron donors

    International Nuclear Information System (INIS)

    Gao Liping; Ding Guojing; Li Chaolong; Wang Yuechuan

    2011-01-01

    Viologen-functionalized copolymer COPV 2+ was synthesized by copolymer graft-modified, which was crosslinked by NH 3 .H 2 O gas-fumigated at 25 deg. C for 4 h due to the condensation of the siloxanes of COPV 2+ film. Simultaneously, different donor/acceptor systems had been prepared based on crosslinked polyviologen film (COPV 2+ ) and N,N,N',N'-tetramethyl-1,4-phenylenediamine (TMPD) or hydroxyethylferrocene (HEFc) in order to shorten the response times and improve contrast ratios in response to external photo- and potential stimuli. The evolution of structures from COPO to COPV 2+ is carefully characterized. The COPV 2+ /TMPD and COPV 2+ /HEFc films exhibited both photochromic and electrochromic performances. After UV irradiations, COPV 2+ /TMPD and COPV 2+ /HEFc films changed their colors from colorless to deep blue, while optical transmissions at 610 nm decreased about 64% and 75%, respectively. When removing out from UV irradiation, the colored COPV 2+ /TMPD and COPV 2+ /HEFc films faded to the original colors within about 60 min. When COPV 2+ /TMPD and COPV 2+ /HEFc films were biased with negative voltage of -2.5 V, they changed their colors from colorless to deep blue in 4 s and 3 s, while the optical transmissions at 556 nm decreased about 81% and 75%, respectively. When electric impulse was switched off, the colored COPV 2+ /TMPD and COPV 2+ /HEFc films faded to the original colors within about 7 s and 6 s, respectively.

  18. Quality cost system in electronics

    International Nuclear Information System (INIS)

    Denzer, H.O.

    1978-01-01

    A description is presented of a formal cost of quality system used in an electronic manufacturing facility. The system elements and reports are illustrated. Examples of the use of a quality cost system to measure quality performance and to improve product quality are included. A comparison to industry averages for quality costs is made. The paper attempts to show that the collection and use of quality costs are an aid to management and can be accompanied by improved product quality

  19. Mechanism and Dynamics of Charge Transfer in Donor-Bridge-Acceptor Systems

    NARCIS (Netherlands)

    Gorczak-Vos, N.

    2016-01-01

    Photoinduced charge transfer in organic materials is a fundamental process in various biological and technological areas. Donor-bridge-acceptor (DBA) molecules are used as model systems in numerous theoretical and experimental work to systematically study and unravel the underlying mechanisms of

  20. Quality assurance records system

    International Nuclear Information System (INIS)

    1979-01-01

    This Safety Guide was prepared as part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to nuclear power plants. It supplements the IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants (IAEA Safety Series No.50-C-QA), which requires that for each nuclear power plant a system for the generation, identification, collection, indexing, filing, storing, maintenance and disposition of quality assurance records shall be established and executed in accordance with written procedures and instructions. The purpose of this Safety Guide is to provide assistance in the establishment and operation of such a system. An orderly established and maintained records system is considered to be part of the means of providing a basis for an appropriate level of confidence that the activities which affect the quality of a nuclear power plant have been performed in accordance with the specific requirements and that the required quality has been achieved and is maintained

  1. Water quality diagnosis system

    International Nuclear Information System (INIS)

    Nagase, Makoto; Asakura, Yamato; Sakagami, Masaharu

    1989-01-01

    By using a model representing a relationship between the water quality parameter and the dose rate in primary coolant circuits of a water cooled reactor, forecasting for the feature dose rate and abnormality diagnosis for the water quality are conducted. The analysis model for forecasting the reactor water activity or the dose rate receives, as the input, estimated curves for the forecast Fe, Ni, Co concentration in feedwater or reactor water pH, etc. from the water quality data in the post and forecasts the future radioactivity or dose rate in the reactor water. By comparing the result of the forecast and the setting value such as an aimed value, it can be seen whether the water quality at present or estimated to be changed is satisfactory or not. If the quality is not satisfactory, it is possible to take an early countermeasure. Accordingly, the reactor water activity and the dose rate can be kept low. Further, the basic system constitution, diagnosis algorithm, indication, etc. are identical between BWR and PWR reactors, except for only the difference in the mass balance. (K.M.)

  2. Health-related quality of life and patient burden in patients with split-thickness skin graft donor site wounds.

    Science.gov (United States)

    Humrich, Marco; Goepel, Lisa; Gutknecht, Mandy; Lohrberg, David; Blessmann, Marco; Bruning, Guido; Diener, Holger; Dissemond, Joachim; Hartmann, Bernd; Augustin, Matthias

    2018-04-01

    Split-thickness skin grafting is a common procedure to treat different kinds of wounds. This systematic, multicentre, observational, cross-sectional study of adult patients with split-thickness skin graft (STSG) donor site wounds was conducted to evaluate quality of life (QoL) impairments caused by donor site wounds following split-thickness skin grafting. Therefore, 112 patients from 12 wound centres in Germany were examined based on patient and physician questionnaires as well as a physical examination of the donor site wound. Most indications for skin grafting were postsurgical treatment (n = 51; 42.5%) and chronic wounds (n = 47; 39.2%). European QoL visual analoque scale (EQ VAS) averaged 64.7 ± 23.3, European QoL 5 dimensions (EQ-5D) averaged 77.4 ± 30.0. Wound-QoL (range: 0-4) was rated 0.8 ± 0.8 post-surgery and 0.4 ± 0.6 at the time of survey (on average 21 weeks between the time points). Compared to averaged Wound-QoL scores of chronic wounds donor site-related QoL impairments in split-thickness skin-graft patients were less pronounced. There were significant differences in patient burden immediately after surgery compared to the time of the survey, with medium effect sizes. This supports the hypothesis that faster healing of the donor site wound leads to more favourable patient-reported outcomes. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  3. The nutritive and immunoprotective quality of human milk beyond 1 year postpartum: are lactation-duration-based donor exclusions justified?

    Science.gov (United States)

    Perrin, Maryanne Tigchelaar; Fogleman, April; Allen, Jonathan C

    2013-08-01

    Donor human milk is critical for the fragile preterm infant who does not have access to his or her mother's milk, improving survival rates and quality of survival and decreasing hospital stay. Despite the opening of donor milk banks around the world, shortages continue as demand for donor milk exceeds supply. One potential means of increasing supply is by reducing exclusion criteria that prohibit mothers from donating milk based on duration of lactation. Minimal research has been done on the composition of human milk during the second year of lactation, with most research focusing on the nutritive compounds and not the immunoprotective compounds. Several immunoprotective compounds, including lysozyme, lactoferrin, secretory immunoglobulin A, and oligosaccharides, are abundant in human milk compared to bovine-based infant formula and are partially or fully retained during Holder pasteurization, making them an important differentiating feature of donor milk. A PubMed search was conducted to review studies in human milk composition during the second year of lactation. Limitations of existing research include sample collection protocols, small study sizes, and use of populations that may have been at risk for nutritional deficiencies. Stable concentrations of several components were reported including protein, lactose, iron, copper, lactoferrin, and secretory immunoglobulin A. Lysozyme concentration increased during extended lactation, while zinc and calcium concentrations declined into the second year. Conflicting findings were reported on fat content, and no information was available regarding oligosaccharide content. More research is needed to create evidence-based guidelines regarding the nutritive and immunoprotective value of donor milk throughout the course of lactation.

  4. Organic charge transfer phase formation in thin films of the BEDT-TTF/TCNQ donor-acceptor system

    DEFF Research Database (Denmark)

    Solovyeva, Vita; Keller, K.; Huth, M.

    2009-01-01

    We have performed charge transfer phase formation studies on the donor/acceptor system bis-(ethylendithio)tetrathiafulvalene (BEDT-TTF)/tetracyanoquinodimethane,(TCNQ) by means of physical vapor deposition. We prepared donor/acceptor bilayer structures on glass and Si(100)/SiO substrates held...

  5. [Quality system Vision 2000].

    Science.gov (United States)

    Pasini, Evasio; Pitocchi, Oreste; de Luca, Italo; Ferrari, Roberto

    2002-12-01

    A recent document of the Italian Ministry of Health points out that all structures which provide services to the National Health System should implement a Quality System according to the ISO 9000 standards. Vision 2000 is the new version of the ISO standard. Vision 2000 is less bureaucratic than the old version. The specific requests of the Vision 2000 are: a) to identify, to monitor and to analyze the processes of the structure, b) to measure the results of the processes so as to ensure that they are effective, d) to implement actions necessary to achieve the planned results and the continual improvement of these processes, e) to identify customer requests and to measure customer satisfaction. Specific attention should be also dedicated to the competence and training of the personnel involved in the processes. The principles of the Vision 2000 agree with the principles of total quality management. The present article illustrates the Vision 2000 standard and provides practical examples of the implementation of this standard in cardiological departments.

  6. Effect of donor orientation on ultrafast intermolecular electron transfer in coumarin-amine systems

    International Nuclear Information System (INIS)

    Singh, P. K.; Nath, S.; Bhasikuttan, A. C.; Kumbhakar, M.; Mohanty, J.; Sarkar, S. K.; Mukherjee, T.; Pal, H.

    2008-01-01

    Effect of donor amine orientation on nondiffusive ultrafast intermolecular electron transfer (ET) reactions in coumarin-amine systems has been investigated using femtosecond fluorescence upconversion measurements. Intermolecular ET from different aromatic and aliphatic amines used as donor solvents to the excited coumarin-151 (C151) acceptor occurs with ultrafast rates such that the shortest fluorescence lifetime component (τ 1 ) is the measure of the fastest ET rate (τ 1 =τ ET fast =(k ET fast ) -1 ), assigned to the C151-amine contact pairs in which amine donors are properly oriented with respect to C151 to maximize the acceptor-donor electronic coupling (V el ). It is interestingly observed that as the amine solvents are diluted by suitable diluents (either keeping solvent dielectric constant similar or with increasing dielectric constant), the τ 1 remains almost in the similar range as long as the amine dilution does not cross a certain critical limit, which in terms of the amine mole fraction (x A ) is found to be ∼0.4 for aromatic amines and ∼0.8 for aliphatic amines. Beyond these dilutions in the two respective cases of the amine systems, the τ 1 values are seen to increase very sharply. The large difference in the critical x A values involving aromatic and aliphatic amine donors has been rationalized in terms of the largely different orientational restrictions for the ET reactions as imposed by the aliphatic (n-type) and aromatic (π-type) nature of the amine donors [A. K. Satpati et al., J. Mol. Struct. 878, 84 (2008)]. Since the highest occupied molecular orbital (HOMO) of the n-type aliphatic amines is mostly centralized at the amino nitrogen, only some specific orientations of these amines with respect to the close-contact acceptor dye [also of π-character; A. K. Satpati et al., J. Mol. Struct. 878, 84 (2008) and E. W. Castner et al., J. Phys. Chem. A 104, 2869 (2000)] can give suitable V el and thus ultrafast ET reaction. In contrary, the

  7. Impact of donor- and collection-related variables on product quality in ex utero cord blood banking.

    Science.gov (United States)

    Askari, Sabeen; Miller, John; Chrysler, Gayl; McCullough, Jeffrey

    2005-02-01

    Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 x 10(7), and 5.2 x 10(6), respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks' gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.

  8. Validation of systems biology derived molecular markers of renal donor organ status associated with long term allograft function.

    Science.gov (United States)

    Perco, Paul; Heinzel, Andreas; Leierer, Johannes; Schneeberger, Stefan; Bösmüller, Claudia; Oberhuber, Rupert; Wagner, Silvia; Engler, Franziska; Mayer, Gert

    2018-05-03

    Donor organ quality affects long term outcome after renal transplantation. A variety of prognostic molecular markers is available, yet their validity often remains undetermined. A network-based molecular model reflecting donor kidney status based on transcriptomics data and molecular features reported in scientific literature to be associated with chronic allograft nephropathy was created. Significantly enriched biological processes were identified and representative markers were selected. An independent kidney pre-implantation transcriptomics dataset of 76 organs was used to predict estimated glomerular filtration rate (eGFR) values twelve months after transplantation using available clinical data and marker expression values. The best-performing regression model solely based on the clinical parameters donor age, donor gender, and recipient gender explained 17% of variance in post-transplant eGFR values. The five molecular markers EGF, CD2BP2, RALBP1, SF3B1, and DDX19B representing key molecular processes of the constructed renal donor organ status molecular model in addition to the clinical parameters significantly improved model performance (p-value = 0.0007) explaining around 33% of the variability of eGFR values twelve months after transplantation. Collectively, molecular markers reflecting donor organ status significantly add to prediction of post-transplant renal function when added to the clinical parameters donor age and gender.

  9. General theory of excitation energy transfer in donor-mediator-acceptor systems.

    Science.gov (United States)

    Kimura, Akihiro

    2009-04-21

    General theory of the excitation energy transfer (EET) in the case of donor-mediator-acceptor system was constructed by using generalized master equation (GME). In this theory, we consider the direct and indirect transitions in the EET consistently. Hence, our theory includes the quantum mechanical interference between the direct and indirect transitions automatically. Memory functions in the GME were expressed by the overlap integrals among the time-dependent emission spectrum of the donor, the absorption spectrum of the mediator, the time-dependent emission spectrum of the mediator, and the absorption spectrum of the acceptor. In the Markov limit of the memory functions, we obtained the rate of EET which consists of three terms due to the direct transition, the indirect transition, and the interference between them. We found that the interference works effectively in the limit of slow thermalization at the intermediate state. The formula of EET rate in this limit was expressed by the convolution of the EET interaction and optical spectra. The interference effect strongly depends on the width of the absorption spectrum of mediator molecule and the energy gap between the donor and the mediator molecules.

  10. Quality management systems in radiology

    Directory of Open Access Journals (Sweden)

    Geoffrey K. Korir

    2013-08-01

    Objective: To assess the level of quality management systems in X-ray medical facilities in Kenya. Methods: Quality management inspection, quality control performance tests and patient radiation exposure were assessed in 54 representative X-ray medical facilities. Additionally, a survey of X-ray examination frequency was conducted in 140 hospitals across the country. Results: The overall findings placed the country’s X-ray imaging quality management systems at 61±3% out of a possible 100%. The most and the least quality assurance performance indicators were general radiography X-ray equipment quality control tests at 88±4%, and the interventional cardiology adult examinations below diagnostic reference level at 25±1%, respectively. Conclusions: The study used a systematic evidence-based approach for the assessment of national quality management systems in radiological practice in clinical application, technical conduct of the procedure, image quality criteria, and patient characteristics as part of the quality management programme.

  11. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  12. Information System Quality Assessment Methods

    OpenAIRE

    Korn, Alexandra

    2014-01-01

    This thesis explores challenging topic of information system quality assessment and mainly process assessment. In this work the term Information System Quality is defined as well as different approaches in a quality definition for different domains of information systems are outlined. Main methods of process assessment are overviewed and their relationships are described. Process assessment methods are divided into two categories: ISO standards and best practices. The main objective of this w...

  13. Bond of donor-acceptor interaction in metal-ligand system with energies of Fermi electrons

    International Nuclear Information System (INIS)

    Vlasov, Yu.V.; Khentov, V.Ya.; Velikanova, L.N.; Semchenko, V.V.

    1993-01-01

    Role of quantum nature of metal (W, Mo and others) in donor-acceptor interaction of metal salicylalaniline - aprotic solvent was discussed. The dependence of dissolution rate and activation energy of donor-acceptor interaction on electron energy was established

  14. Physician Quality Reporting System

    Data.gov (United States)

    U.S. Department of Health & Human Services — PQRS is a reporting program that uses a combination of incentive payments and negative payment adjustments to promote reporting of quality information by eligible...

  15. Magnetic field effects on geminate reactions. Study of anthraquinone - hydrogen donors systems

    International Nuclear Information System (INIS)

    Vidal, Marie-Helene

    1987-01-01

    This study is devoted to magnetic field effects on chemical reactions which involve a radical pair with correlated spins (radical in a 'cage'). In the first part, the radical pair theory is described: mechanisms of singlet-triplet mixing, the different interactions inside the pair and a quantum mechanical treatment of the radical pair. The details of the experimental method (nanosecond laser flash photolysis) are reported in the second part. In the third part are shown experimental results obtained on Anthraquinone (AQ) - Hydrogen donors systems: - There is no magnetic field effect in homogeneous solution even at a high viscosity. The absorption spectra of the different reaction intermediates are obtained. - However a magnetic field effect is put forward when AQ is introduced in SDS micelles which are hydrogen donors. The absorption spectrum of the AQH · . semi-quinone radical in 'cage' is shown and a mechanism is proposed for its disappearance to generate the AQH-S and AQH 2 species. - The addition of 9, 10 Dihydroanthracene (DH2) inside the micelle near AQ induces an increase of the magnetic field effect by creation of (AQH · . - DH · . ) pairs which diffuse slowly. - Fixed radical pairs in a protein matrix were studied in reaction centers of photosynthetic bacteria: in that case, the half effect field is shifted to low fields when compared to the previously described systems. (author) [fr

  16. Dissipative exciton transfer in donor-bridge-acceptor systems: numerical renormalization group calculation of equilibrium properties

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, Sabine [Theoretische Physik III, Elektronische Korrelationen und Magnetismus, Universitaet Augsburg, 86135 Augsburg (Germany); Tong, Ning-Hua [Institut fuer Theorie der Kondensierten Materie, Universitaet Karlsruhe, 76128 Karlsruhe (Germany); Bulla, Ralf [Theoretische Physik III, Elektronische Korrelationen und Magnetismus, Universitaet Augsburg, 86135 Augsburg (Germany)

    2006-07-05

    We present a detailed model study of exciton transfer processes in donor-bridge-acceptor (DBA) systems. Using a model which includes the intermolecular Coulomb interaction and the coupling to a dissipative environment we calculate the phase diagram, the absorption spectrum as well as dynamic equilibrium properties with the numerical renormalization group. This method is non-perturbative and therefore allows one to cover the full parameter space, especially the case when the intermolecular Coulomb interaction is of the same order as the coupling to the environment and perturbation theory cannot be applied. For DBA systems with up to six sites we found a transition to the localized phase (self-trapping) depending on the coupling to the dissipative environment. We discuss various criteria which favour delocalized exciton transfer.

  17. Dissipative exciton transfer in donor-bridge-acceptor systems: numerical renormalization group calculation of equilibrium properties.

    Science.gov (United States)

    Tornow, Sabine; Tong, Ning-Hua; Bulla, Ralf

    2006-07-05

    We present a detailed model study of exciton transfer processes in donor-bridge-acceptor (DBA) systems. Using a model which includes the intermolecular Coulomb interaction and the coupling to a dissipative environment we calculate the phase diagram, the absorption spectrum as well as dynamic equilibrium properties with the numerical renormalization group. This method is non-perturbative and therefore allows one to cover the full parameter space, especially the case when the intermolecular Coulomb interaction is of the same order as the coupling to the environment and perturbation theory cannot be applied. For DBA systems with up to six sites we found a transition to the localized phase (self-trapping) depending on the coupling to the dissipative environment. We discuss various criteria which favour delocalized exciton transfer.

  18. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  19. System management and quality assurance

    International Nuclear Information System (INIS)

    Sastry, A.M.

    1989-01-01

    This paper describes the principles of system management and shows the relationship to quality assurance. It discusses the need for balanced attention to all the project management controls required for project success

  20. A quality of life study in 20 adult long-term survivors of unrelated donor bone marrow transplantation.

    Science.gov (United States)

    Marks, D I; Gale, D J; Vedhara, K; Bird, J M

    1999-07-01

    There are few specific data available concerning quality of life (QOL) of survivors of unrelated donor bone marrow transplantation (UD-BMT). The procedure is expensive, difficult and is being employed increasingly yet we have little information concerning the QOL of survivors to justify this intervention. In this study, 20 long-term (>1 year post-BMT) survivors were studied with four self report questionnaires designed to assess quality of life, satisfaction with life, social support and employment status. Overall, satisfaction with life measures was above average but there was dissatisfaction with physical strength and appearance. The post-transplant employment data indicates that 60% of long-term survivors returned to full-time work and 15% to part-time work. Failure to return to work was not correlated with graft-versus-host disease (GVHD), relapse, age at or time since transplant. In general, there was a good correlation between the clinician's and patient's view of their health but the clinician's assessment of the patients mental health and energy was higher than the patients reported. Further research is required in the area of QOL post-UD-BMT. This will enable transplant physicians to counsel patients better pre-BMT and to evaluate fully the results achieved by different centres performing the procedure.

  1. Donor Tracker: An Innovative Real-Time Tracking System for Blood ...

    African Journals Online (AJOL)

    In this paper, we explore the possibility of using location-aware computing to track blood donors in Mauritius and locate the nearest donor in cases of emergencies and whenever fresh blood is ... Keywords: Context-awareness, location-awareness, mobile and ubiquitous computing, location sensing technique, real-time.

  2. QUEST: Quality of Expert Systems

    NARCIS (Netherlands)

    Perre, M.

    1991-01-01

    TNO Physics and Electronics laboratory, in collaboration with the University of Limburg and the Research Institute for Knowledge Systems, worked on a technology project named 'QUEST: Quality of Expert Systems' [FEL90]. QUEST was carried out under commision of the Dutch Ministry of Defence. A strong

  3. SOME ASPECTS OF IMMUNE SYSTEM FUNCTIONING IN HEALTHY DONORS SUBJECTED TO XENOGENOUS EXPOSURE

    Directory of Open Access Journals (Sweden)

    O. O. Obukhova

    2006-01-01

    Full Text Available Abstract. In present work, we studied some interrelations between tobacco smoking and the processes of immune system stimulation in healthy blood donors. In our opinion, this issue is especially important for the big industrial center, with rather strong antigenic exposure of the organism. The levels of circulating immune complexes (CIC were used as a marker index which reflects specific antigen-antibody interactions during inflammation. According to the results obtained, the majority of persons who have high CIC levels were tobacco smokers (53.76%. Moreover, the percentage of persons with high CIC content, like as the mean values of this index is increased proportionally to the duration of smoking. A mixture of tobacco smoke components seems to exert direct toxic effect upon various compartments of the immune system and causes local irritation of bronchial tree, thus producing local and systemic inflammatory reaction. It is, possibly, an additional factor which determines activation of immune system, with a background of adverse antropogenic exposures typical to industrial centers. The data obtained allow us to affirm a toxic action of tobacco smoke upon the organism of smokers, with development of inflammatory reactions that are displayed as increased CIC levels at preclinical stage.

  4. Towards a global system of vigilance and surveillance in unrelated donors of haematopoietic progenitor cells for transplantation.

    Science.gov (United States)

    Shaw, B E; Chapman, J; Fechter, M; Foeken, L; Greinix, H; Hwang, W; Phillips-Johnson, L; Korhonen, M; Lindberg, B; Navarro, W H; Szer, J

    2013-11-01

    Safety of living donors is critical to the success of blood, tissue and organ transplantation. Structured and robust vigilance and surveillance systems exist as part of some national entities, but historically no global systems are in place to ensure conformity, harmonisation and the recognition of rare adverse events (AEs). The World Health Assembly has recently resolved to require AE/reaction (AE/R) reporting both nationally and globally. The World Marrow Donor Association (WMDA) is an international organisation promoting the safety of unrelated donors and progenitor cell products for use in haematopoietic progenitor cell (HPC) transplantation. To address this issue, we established a system for collecting, collating, analysing, distributing and reacting to serious adverse events and reactions (SAE/R) in unrelated HPC donors. The WMDA successfully instituted this reporting system with 203 SAE/R reported in 2011. The committee generated two rapid reports, reacting to specific SAE/R, resulting in practice changing policies. The system has a robust governance structure, formal feedback to the WMDA membership and transparent information flows to other agencies, specialist physicians and transplant programs and the general public.

  5. NGOs and government partnership for health systems strengthening: A qualitative study presenting viewpoints of government, NGOs and donors in Pakistan

    Directory of Open Access Journals (Sweden)

    Rizvi Narjis

    2011-05-01

    Full Text Available Abstract Background Health systems are expected to serve the population needs in an effective, efficient and equitable manner. Therefore, the importance of strengthening of public, private and community health systems has been emphasized time and again. In most of the developing countries, certain weaknesses and gaps in the government health systems have been hampering the achievement of improved health outcomes. Public sector in Pakistan has been deficient in the capacity to deliver equitable and quality health services and thus has been grossly underutilized. Methods A qualitative study comprising in-depth interviews was conducted capturing the perceptions of the government functionaries, NGO representatives and donor community about the role and position of NGOs in health systems strengthening in Pakistan's context. Analysis of the data was done manually to generate nodes, sub-nodes and themes. Results Since many years, international and local non-governmental organizations (NGOs have endeavored to fill the gaps in health service delivery, research and advocacy. NGOs have relatively performed better and achieved the results because of the flexible planning and the ability to design population based projects on health education, health promotion, social marketing, community development and advocacy. This paper captures the need and the opportunity of public private partnership in Pakistan and presents a framework for a meaningful engagement of the government and the private and nonprofit NGOs. Conclusion Involving the NGOs for health system strengthening may eventually contribute to create a healthcare system reflecting an increased efficiency, more equity and good governance in the wake of the Millennium Development Goals. Nevertheless, few questions need to be answered and pre-requisites have to be fulfilled before moving on.

  6. The donor line break cannula: effect on the donation process, blood component quality and transfusion microbiology testing of an important new blood bag safety feature.

    Science.gov (United States)

    Nightingale, M J; Beard, M J; Bennett, J; Hambleton, R; Ramskill, S; Thomas, S

    2013-08-01

    The use of blood packs with an integral sampling system can result in anti-coagulant from the main bag reaching the sample pouch via the donor line, causing delayed coagulation of blood samples. In NHS Blood and Transplant, this has prevented the use of serum, the preferred matrix for transfusion microbiology (TM) testing, which has led to an increased false positive rate with ethylenediaminetetraacetic acid (EDTA) plasma. There is also a remote possibility of false negative results owing to sample dilution. Manufacturers have responded by offering packs with a donor line break cannula (DLBC) to prevent these adverse effects. The aims of this study were to assess the impact of DLBC packs on donation, blood component quality and of the potential return to serum for TM testing. DLBC packs from three manufacturers were assessed against control packs of the same dimensions and configuration. Donation duration, flow rate, platelet factor 4, prothrombin fragment 1+2, haemolysis and collection and processing incidents were compared. Results indicated no clinically significant adverse effect from the DLBC on the activation state of platelets, the coagulation cascade or increased haemolysis. Donation duration and blood collection and processing incident rates for DLBC packs were not significantly different to controls. The use of DLBC packs would reduce the complexity of manipulations during blood collection and therefore the likelihood of microbially contaminated donations (incorrect skin core diversion) and false negative TM tests. DLBC packs would enable the use of serum for TM testing with a significant reduction in false positive tests compared to EDTA plasma. © 2013 The Authors. Transfusion Medicine © 2013 British Blood Transfusion Society.

  7. ISO 9001 quality management systems

    CERN Document Server

    Natarajan, Dhanasekharan

    2017-01-01

    This book explains the requirements of ISO 9001 for establishing quality management system (QMS) for an organization. The requirements are illustrated with examples from industries for understanding the requirements and preparing the documents of QMS with high clarity. Methods of integrating ISO 9001 requirements with enterprise resource planning (ERP) software are presented. The software integrated approach enables process owners to focus on their core tasks of achieving the planned outputs of processes and the software generates quality records automatically.

  8. Quality management system in ISTC 'Ukryttia'

    International Nuclear Information System (INIS)

    Ershova, N.N.; Klyuchnikov, A.A.; Lagutin, I.G.

    2003-01-01

    Some structural and certification aspects of ISTC 'Ukryttia' quality system are seen,and main principles of adaptation of existing quality system model to quality management system model in conformity with ISO 9001:2000 standard are shown

  9. Resonant and non-resonant components of the rate of a population transfer in hybrid donor-acceptor systems

    Czech Academy of Sciences Publication Activity Database

    Menšík, Miroslav; Král, Karel

    2013-01-01

    Roč. 5, č. 6 (2013), s. 565-568 ISSN 2164-6627 R&D Projects: GA MŠk(CZ) OC10007; GA MŠk LH12186; GA ČR(CZ) GAP205/10/2280 Institutional support: RVO:61389013 ; RVO:68378271 Keywords : energy transfer * hybrid donor-acceptor system Subject RIV: BM - Solid Matter Physics ; Magnetism

  10. Detection of cytomegalovirus in blood donors by PCR using the digene SHARP signal system assay: effects of sample preparation and detection methodology.

    OpenAIRE

    Krajden, M; Shankaran, P; Bourke, C; Lau, W

    1996-01-01

    Cytomegalovirus (CMV) is an important cause of transfusion-associated morbidity and mortality; however, only 0.4 to 12% of the blood products obtained from seropositive blood donors transmit infection. The effects of three commercially available whole-blood sample preparation kits on the detection of CMV PCR products by a semiquantitative adaptation of the Digene SHARP Signal System Assay (DSSSA) in samples from volunteer blood donors was assessed. Of 101 samples from seropositive blood donor...

  11. Ultrasmall magnetic field-effect and sign reversal in transistors based on donor/acceptor systems

    Directory of Open Access Journals (Sweden)

    Thomas Reichert

    2017-05-01

    Full Text Available We present magnetoresistive organic field-effect transistors featuring ultrasmall magnetic field-effects as well as a sign reversal. The employed material systems are coevaporated thin films with different compositions consisting of the electron donor 2,2',7,7'-tetrakis-(N,N-di-p-methylphenylamino-9,9'-spirobifluorene (Spiro-TTB and the electron acceptor 1,4,5,8,9,12-hexaazatriphenylene hexacarbonitrile (HAT-CN. Intermolecular charge transfer between Spiro-TTB and HAT-CN results in a high intrinsic charge carrier density in the coevaporated films. This enhances the probability of bipolaron formation, which is the process responsible for magnetoresistance effects in our system. Thereby even ultrasmall magnetic fields as low as 0.7 mT can influence the resistance of the charge transport channel. Moreover, the magnetoresistance is drastically influenced by the drain voltage, resulting in a sign reversal. An average B0 value of ≈2.1 mT is obtained for all mixing compositions, indicating that only one specific quasiparticle is responsible for the magnetoresistance effects. All magnetoresistance effects can be thoroughly clarified within the framework of the bipolaron model.

  12. Quality system for Medical laboratories

    Directory of Open Access Journals (Sweden)

    Shiva Raj K.C.

    2015-03-01

    Full Text Available According to William Edwards Deming “Good quality does not necessarily mean high quality. Instead it means a predicable degree of uniformity and dependability at low cost with a quality suited to the market.” Whereas according to famous engineer and management consultant Joseph M. Juran quality is “fitness for purpose”. It should meet the customers’ expectations and requirements, should be cost effective.ISO began in 1926 as the International Federation of the National Standardizing Associations (ISA. The name, "ISO" was derived from the Greek word "isos" meaning "equal". (The relation to standards is that if two objects meet the same standard, they should be equal. This name eliminates any confusion that could result from the translation of "International Organization for Standardization" into different languages which would lead to different acronyms.In health sector, quality plays pivotal role, as it is directly related to patient’s care. Earlier time, health service was simple, quite safe but ineffective. Now health care system is an organizational system with more complex processes to deliver care. Medical laboratory service is an integral part in patient’s management system. So, for everyone involved in the treatment of the patient, the accuracy, reliability and safety of those services must be the primary concerns. Accreditation is a significant enabler of quality, thereby delivering confidence to healthcare providers, clinicians, the medical laboratories and the patients themselves.ISO announced meeting in Philadelphia to form a technical committee to develop a new standard for medical laboratory quality. It took 7 years for the creation of a new Quality standard for medical laboratories. It was named as “ISO 15189” and was first published in 2003. The ISO has released three versions of the standard. The first two were released in 2003 and 2007. In 2012, a revised and updated version of the standard, ISO 15189

  13. Quality Systems Implementation in the Pharmaceutical Industry

    African Journals Online (AJOL)

    Nafiisah

    quality standards imposed on local pharmaceutical manufacturers. Keywords: Quality/ .... GMP is concerned with both production and quality control. It is aimed ... in the European pharmaceutical industry in designing their quality systems:.

  14. Anatomic variations in vascular and collecting systems of kidneys from deceased donors.

    Science.gov (United States)

    Costa, H C; Moreira, R J; Fukunaga, P; Fernandes, R C; Boni, R C; Matos, A C

    2011-01-01

    Nephroureterectomy for transplantation has increased owing to the greater number of deceased donors. Anatomic variations may complicate the procedure or, if unrecognized, compromise the viability of kidneys for transplantation. We reviewed 254 surgical descriptions of nephroureterectomy specimens from January 2008 to December 2009. All organs collected according by standard techniques were evaluated for age, cause of death, renal function, frequency of injury during the procedure, as well as variations in the vascular and collecting systems. The mean donor age was 42 years (range, 2-74). The mean serum creatinine was 1.2 mg/dL (range, 1.0-7.0). The causes of death were cerebrovascular cause (stroke; n = 130), traumatic brain injury (n = 81) or other cause (n = 43). Among the anatomic variations: 8.6% (n = 22) were right arterial anatomical variations: 19 cases with 2 arteries and 3 cases with 3 arteries. In 25 cases (9.8%) the identified variation was the left artery: 2 arteries (n = 23), 3 arteries (n = 1) and 4 arteries (n = 1). We observed 9.8% on right side and 1.5% on left side venous anatomic variations, including 24 cases with 2 veins on the right side and 4 cases with 2 veins on the left side. Three cases of a retroaortic left renal vein and 1 case of a retro necklace vein (anterior and posterior to the aorta). Two cases of ureteral duplication were noted on the left and 1 on the right kidney. There were 3 horseshoe and 1 pelvic kidney. In 7.5% of cases, an injury to the graft included ureteral (n = 3), arterial (n = 10), or venous (n = 6). The most common anatomic variation was arterial (17.8%). Duplication of the renal vein was more frequent on the right. The high incidences of anatomic variations require more attention in the dissection of the renal hilum to avoid an injury that may compromise the graft. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  16. Should We Formulate an Incentivized Model Facilitating Kidney Donation from Living Donors? A Focus on Turkey's Current System.

    Science.gov (United States)

    Avci, Ercan

    2018-04-23

    Kidney transplantation is a lifesaving medical treatment. However, very high demand for kidneys with low kidney donation causes a black market that exploits patients' desperation and donors' vulnerability. The current kidney donation programs fail to produce promising results to avoid illegal and unethical kidney trafficking and commercialism. Even though the primary goal of kidney donation is to increase the number of deceased organ donations, in some countries, like Turkey, due to religious or cultural concerns, it is impossible to supply adequate deceased kidney donations. In this view, the aim of this paper is to examine kidney trafficking in the scope of Turkey's current organ donation system and propose a new model, named the Incentivized Kidney Donation Model (IKDM), to increase kidney donation from living donors. The model encompasses the following benefits offered to kidney donors; lifetime health insurance, exemptions from copayments/contribution shares, priority when receiving an organ, priority when finding a job, income tax exemptions for salaried employees, and free or discounted public utilities. This normative model has the potential to promote donors' altruistic acts as well as the solidarity and loyalty among members of a society without violating ethical values and internationally accepted principles. © 2018 John Wiley & Sons Ltd.

  17. Organic donor-acceptor thin film systems. Towards optimized growth conditions

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Kerstin Andrea

    2009-06-30

    In this work the preparation of organic donor-acceptor thin films was studied. A chamber for organic molecular beam deposition was designed and integrated into an existing deposition system for metallic thin films. Furthermore, the deposition system was extended by a load-lock with integrated bake-out function, a chamber for the deposition of metallic contacts via stencil mask technique and a sputtering chamber. For the sublimation of the organic compounds several effusion cells were designed. The evaporation characteristic and the temperature profile within the cells was studied. Additionally, a simulation program was developed, which calculates the evaporation characteristics of different cell types. The following processes were integrated: evaporation of particles, migration on the cell walls and collisions in the gas phase. It is also possible to consider a temperature gradient within the cell. All processes can be studied separately and their relative strength can be varied. To verify the simulation results several evaporation experiments with different cell types were employed. The thickness profile of the prepared thin films was measured position-dependently. The results are in good agreement with the simulation. Furthermore, the simulation program was extended to the field of electron beam induced deposition (EBID). The second part of this work deals with the preparation and characterization of organic thin films. The focus hereby lies on the charge transfer salt (BEDT-TTF)(TCNQ), which has three known structure variants. Thin films were prepared by different methods of co-evaporation and were studied with optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy (EDX).The formation of the monoclinic phase of (BEDT-TTF)(TCNQ) could be shown. As a last part tunnel structures were prepared as first thin film devices and measured in a He{sub 4} cryostat. (orig.)

  18. Dr. Liver: A preoperative planning system of liver graft volumetry for living donor liver transplantation.

    Science.gov (United States)

    Yang, Xiaopeng; Yang, Jae Do; Yu, Hee Chul; Choi, Younggeun; Yang, Kwangho; Lee, Tae Beom; Hwang, Hong Pil; Ahn, Sungwoo; You, Heecheon

    2018-05-01

    Manual tracing of the right and left liver lobes from computed tomography (CT) images for graft volumetry in preoperative surgery planning of living donor liver transplantation (LDLT) is common at most medical centers. This study aims to develop an automatic system with advanced image processing algorithms and user-friendly interfaces for liver graft volumetry and evaluate its accuracy and efficiency in comparison with a manual tracing method. The proposed system provides a sequential procedure consisting of (1) liver segmentation, (2) blood vessel segmentation, and (3) virtual liver resection for liver graft volumetry. Automatic segmentation algorithms using histogram analysis, hybrid level-set methods, and a customized region growing method were developed. User-friendly interfaces such as sequential and hierarchical user menus, context-sensitive on-screen hotkey menus, and real-time sound and visual feedback were implemented. Blood vessels were excluded from the liver for accurate liver graft volumetry. A large sphere-based interactive method was developed for dividing the liver into left and right lobes with a customized cutting plane. The proposed system was evaluated using 50 CT datasets in terms of graft weight estimation accuracy and task completion time through comparison to the manual tracing method. The accuracy of liver graft weight estimation was assessed by absolute difference (AD) and percentage of AD (%AD) between preoperatively estimated graft weight and intraoperatively measured graft weight. Intra- and inter-observer agreements of liver graft weight estimation were assessed by intraclass correlation coefficients (ICCs) using ten cases randomly selected. The proposed system showed significantly higher accuracy and efficiency in liver graft weight estimation (AD = 21.0 ± 18.4 g; %AD = 3.1% ± 2.8%; percentage of %AD > 10% = none; task completion time = 7.3 ± 1.4 min) than the manual tracing method (AD = 70

  19. ISO 9000 Quality Management System

    Science.gov (United States)

    Hadjicostas, Evsevios

    The ISO 9000 series describes a quality management system applicable to any organization. In this chapter we present the requirements of the standard in a way that is as close as possible to the needs of analytical laboratories. The sequence of the requirements follows that in the ISO 9001:2008 standard. In addition, the guidelines for performance improvement set out in the ISO 9004 are reviewed. Both standards should be used as a reference as well as the basis for further elaboration.

  20. [Compatibility of different quality control systems].

    Science.gov (United States)

    Invernizzi, Enrico

    2002-01-01

    Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.

  1. Organ Donation European Quality System: ODEQUS project methodology.

    Science.gov (United States)

    Manyalich, M; Guasch, X; Gomez, M P; Páez, G; Teixeira, L

    2013-01-01

    Differences in the number of organ donors among hospitals cannot be explained only by the number of intensive care unit beds used or neurologic patients treated. The figures obtained are influenced by the organizational structure of the donation process and how efficient it is. The Organ Donation European Quality System (ODEQUS) is a 3-year project (from October 2010 to September 2013) co-financed by the European Agency for Health and Consumers (EAHC20091108) which aims to define a methodology to evaluate organ procurement performance at the hospital level. ODEQUS's specific objectives are to identify quality criteria and to develop quality indicators in three types of organ donation (after brain death, after cardiac death, and living donation). Those tools will be useful for hospitals' self-assessment as well as for developing an international auditing model. A consortium has been established involving 14 associated partners from Austria, Croatia, France, Germany, Italy, Poland, Portugal, Romania, Spain, Sweden, and the United Kingdom, as well as five collaborating partners from Greece, Hungary, Malta, Slovenia, and Turkey. The project has been established in three steps: 1) Design of a survey about the use of quality tools in a wide sample of European hospitals; 2) Development of quality criteria and quality indicators by the project experts. The main fields considered have been organizational structures, clinical procedures, and outcomes; and 3) Elaboration of an evaluation system to test the quality indicators in 11 European hospitals. Two types of training have been designed and performed: one concerns the development of quality criteria and quality indicators, whereas another is focused on how to use evaluation tools. Following this methodology, the project has so far identified 131 quality criteria and developed 31 quality indicators. Currently, the quality indicators are being tested in 11 selected hospitals. Copyright © 2013 Elsevier Inc. All rights

  2. Experimental and computed dipole moments in donor-bridge-acceptor systems with p-phenylene and p-carboranediyl bridges

    Czech Academy of Sciences Publication Activity Database

    Drož, L.; Fox, M. A.; Hnyk, Drahomír; Low, P.J.; MacBride, J.A.H.; Všetečka, V.

    2009-01-01

    Roč. 74, č. 1 (2009), s. 131-146 ISSN 0010-0765 R&D Projects: GA MŠk LC523 Grant - others:EPSRC(GB) GR/S80943/01 Institutional research plan: CEZ:AV0Z40320502 Keywords : donor-bridge-acceptor systems * p-carboranylenes * dipole moments Subject RIV: CA - Inorganic Chemistry Impact factor: 0.856, year: 2009

  3. Electron Transfer in Donor-Bridge-Acceptor Systems and Derived Materials

    NARCIS (Netherlands)

    Oosterbaan, W.D.

    2002-01-01

    Some aspects of photoinduced electron transfer (ET) in (electron donor)-bridge-(electron acceptor) compounds (D-B-A) and derived materials are investigated. Aim I is to determine how and to which extent non-conjugated double bonds in an otherwise saturated hydrocarbon bridge affect the rate of

  4. Nano-scale control of energy transfer in the system 'donor-acceptor'

    International Nuclear Information System (INIS)

    Malyukin, Yu.V.; Yefimova, S.L.; Lebedenko, A.N.; Sorokin, A.V.; Borovoy, I.A.

    2005-01-01

    Fluorescence resonance energy transfer (FRET) in a cascade scheme between three amphiphilic dyes 3,3'-dioctadecyloxacarbocyanine perchlorate (DiOC 18 (3), donor), 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiIC 18 (3), acceptor/donor) and 1,1'-dioctadecyl-3,3,3',3'-tetramethylindodicarbocyanine perchlorate (DiIC 18 (5), acceptor) has been investigated at low dye concentration (10 -5 mol/l) in water-micellar solutions due to a forced assembling of dyes in nanoscale volume. The experimental data have revealed that sodium dodecyl sulfate (SDS) micelles solubilize dye molecules such that their hydrophilic heads are in contact with water, while hydrophobic tails are embedded into the hydrocarbon core of the micelle. FRET efficiency has been found to depend on the concentration of dyes in micelles and the most effective when each SDS micelle contains 1 donor (DiOC 18 (3)), 2 acceptor/donor (DiIC 18 (3)) and 4 acceptor (DiIC 18 (5)) molecules

  5. Donor funding health policy and systems research in low- and middle-income countries: how much, from where and to whom.

    Science.gov (United States)

    Grépin, Karen Ann; Pinkstaff, Crossley Beth; Shroff, Zubin Cyrus; Ghaffar, Abdul

    2017-08-31

    The need for sufficient and reliable funding to support health policy and systems research (HPSR) in low- and middle-income countries (LMICs) has been widely recognised. Currently, most resources to support such activities come from traditional development assistance for health (DAH) donors; however, few studies have examined the levels, trends, sources and national recipients of such support - a gap this research seeks to address. Using OECD's Creditor Reporting System database, we classified donor funding commitments using a keyword analysis of the project-level descriptions of donor supported projects to estimate total funding available for HPSR-related activities annually from bilateral and multilateral donors, as well as the Bill and Melinda Gates Foundation, to LMICs over the period 2000-2014. Total commitments to HPSR-related activities have greatly increased since 2000, peaked in 2010, and have held steady since 2011. Over the entire study period (2000-2014), donors committed a total of $4 billion in funding for HPSR-related activities or an average of $266 million a year. Over the last 5 years (2010-2014), donors committed an average of $434 million a year to HPSR-related activities. Funding for HPSR is heavily concentrated, with more than 93% coming from just 10 donors and only represents approximately 2% of all donor funding for health and population projects. Countries in the sub-Saharan African region are the major recipients of HPSR funding. Funding for HPSR-related activities has generally increased over the study period; however, donor support to such activities represents only a small proportion of total DAH and has not grown in recent years. Donors should consider increasing the proportion of funds they allocate to support HPSR activities in order to further build the evidence base on how to build stronger health systems.

  6. Hand-made cloned goat (Capra hircus) embryos—a comparison of different donor cells and culture systems.

    Science.gov (United States)

    Akshey, Yogesh S; Malakar, Dhruba; De, Arun K; Jena, Manoj K; Garg, Shweta; Dutta, Rahul; Pawar, Sachin Kumar; Mukesh, Manisha

    2010-10-01

    Nuclear transfer is a very effective method for propagation of valuable, extinct, and endangered animals. Hand-made cloning (HMC) is an efficient alternative to the conventional micromanipulator-based technique in some domestic species. The present study was carried out for the selection of suitable somatic cells as a nuclear donor and development of an optimum culture system for in vitro culture of zona-free goat cloned embryos. Cleavage and blastocyst rates were observed 72.06 ± 2.94% and 0% for fresh cumulus cells, 81.95 ± 3.40% and 12.74 ± 2.12% for cultured cumulus cells, and 92.94 ± 0.91% and 23.78 ± 3.33% for fetal fibroblast cells, respectively. There was a significant (p cloned embryos and donor cells. In conclusion, the present study describes that the fetal fibroblast cell is a suitable candidate as nuclear donor, and the flat surface culture system is suitable for zona-free blastocyst development by the hand-made cloning technique in the goat.

  7. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  8. Donor vigilance data of a blood transfusion service: A multicenter analysis.

    Science.gov (United States)

    Burkhardt, T; Dimanski, B; Karl, R; Sievert, U; Karl, A; Hübler, C; Tonn, T; Sopvinik, I; Ertl, H; Moog, R

    2015-10-01

    Donor vigilance is an important part of the quality management system of blood transfusion services. The evaluation of donor side effects helps to improve the donation process and donor compliance. The aim of the present study was to evaluate donor vigilance data in whole blood and plasmapheresis donors of a blood donor service. Donors fulfilling current national and European eligibility criteria underwent whole blood and plasmapheresis donation (PCS and MCS+ (Haemonetics, Braintree, USA), A 200 (Fenwal, Round Lake, USA). Whole blood was collected at fixed and mobile sites while plasmaphereses were performed at 8 plasma centers. From 2011 to 2013 donor information was provided for gender, age, body weight, height, first and repeat donation. Donors were monitored for venipuncture and circulatory associated side effects. The total incidences of adverse events were 5004 (0.56%) in repeat donors and 2111 (2.78%) in first time donors for whole blood donation and 3323 (1.01%) and 514 (7.96%) for plasmaphereses, respectively. Circulatory associated events were 2679 (0.30%) for whole blood donation and 1624 (0.49%) for plasmaphereses. Our donor vigilance data of a blood transfusion service show that whole blood and plasmapheresis are safe with low incidences of adverse events. Repeat donation and age are predictors for low rates of adverse events. On the other hand, first time donation and female gender were associated with higher incidences of adverse events. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Donor Hemovigilance Programme in managing Blood Transfusion Needs: Complications of Whole Blood Donation

    OpenAIRE

    S Mangwana

    2013-01-01

    Background: Hemovigilance like quality systems and audits have become an integral part of Blood Transfusion Services in the developed countries and has contributed greatly to its development. Hemovigilance begins with donors and must enable the collection of information on reactions occurring during the donation of blood, selections of donors and to prevent such incidents. The aim of study was to help identify the trends of adverse events , occurring in blood donors at a tertiary-care hospita...

  10. The quality management system applied at PRPN

    International Nuclear Information System (INIS)

    Benar Bukit

    2007-01-01

    The ISO 9001-2000 is an International standard for quality management systems. The application of this quality management system is for guaranteeing that the organizations products will fulfill requirements set by its customers. Here the steps taken to apply the quality management system at PRPN are expounded in five main parts, namely quality management system, responsibilities of the management, resources, product realization, measurement, analysis and repair. (author)

  11. Encapsulation of ropivacaine in a combined (donor-acceptor, ionic-gradient liposomal system promotes extended anesthesia time.

    Directory of Open Access Journals (Sweden)

    Camila Morais Gonçalves da Silva

    Full Text Available Ropivacaine is a local anesthetic with similar potency but lower systemic toxicity than bupivacaine, the most commonly used spinal anesthetic. The present study concerns the development of a combined drug delivery system for ropivacaine, comprised of two types of liposomes: donor multivesicular vesicles containing 250 mM (NH42SO4 plus the anesthetic, and acceptor large unilamellar vesicles with internal pH of 5.5. Both kinds of liposomes were composed of hydrogenated soy-phosphatidylcholine:cholesterol (2:1 mol% and were prepared at pH 7.4. Dynamic light scattering, transmission electron microscopy and electron paramagnetic resonance techniques were used to characterize the average particle size, polydispersity, zeta potential, morphology and fluidity of the liposomes. In vitro dialysis experiments showed that the combined liposomal system provided significantly longer (72 h release of ropivacaine, compared to conventional liposomes (~45 h, or plain ropivacaine (~4 h (p <0.05. The pre-formulations tested were significantly less toxic to 3T3 cells, with toxicity increasing in the order: combined system < ropivacaine in donor or acceptor liposomes < ropivacaine in conventional liposomes < plain ropivacaine. The combined formulation, containing 2% ropivacaine, increased the anesthesia duration up to 9 h after subcutaneous infiltration in mice. In conclusion, a promising drug delivery system for ropivacaine was described, which can be loaded with large amounts of the anesthetic (2%, with reduced in vitro cytotoxicity and extended anesthesia time.

  12. Polythiophenes and fullerene derivatives based donor-acceptor system: topography by atomic force microscopy

    International Nuclear Information System (INIS)

    Marcakova, M. L.; Repovsky, D.; Cik, G.; Velic, D.

    2017-01-01

    The goal of this work is to examine the surface of a polythiophene/fullerene film in order to understand the structure. In this work polythiophene is used as electron donor and fullerene-derivative is used as electron acceptor. Atomic force microscopy (AFM), is an ideal method to study surfaces and nanostructures. Surfaces of fullerene C60 , fullerene-derivates PCBM, polythiophene P12 and a mixture of P12 and PCBM are characterized. In all samples, the average roughness, the arithmetical value of divergence from the high of the surface, is determined concluding that P12 and PCBM mix together well and form a film with specific topography. (authors)

  13. Donor impurity states and related optical response in a lateral coupled dot-ring system under applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Correa, J.D. [Departamento de Ciencias Básicas, Universidad de Medellín, Medellín (Colombia); Mora-Ramos, M.E. [Centro de Investigación en Ciencias, Instituto de Ciencias Básicas y Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, CP 62209 Cuernavaca, Morelos (Mexico); Duque, C.A., E-mail: cduque@fisica.udea.edu.co [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2015-09-01

    A study on the effects of an externally applied electric field on the linear optical absorption and relative refractive index change associated with transitions between off-center donor impurity states in laterally coupled quantum dot-ring system is reported. Electron states are calculated within the effective mass and parabolic band approximations by means of an exact diagonalization procedure. The states and the optical response in each case show significant sensitivity to the geometrical distribution of confining energies as well as to the strength of the applied field.

  14. Donor impurity states and related optical response in a lateral coupled dot-ring system under applied electric field

    International Nuclear Information System (INIS)

    Correa, J.D.; Mora-Ramos, M.E.; Duque, C.A.

    2015-01-01

    A study on the effects of an externally applied electric field on the linear optical absorption and relative refractive index change associated with transitions between off-center donor impurity states in laterally coupled quantum dot-ring system is reported. Electron states are calculated within the effective mass and parabolic band approximations by means of an exact diagonalization procedure. The states and the optical response in each case show significant sensitivity to the geometrical distribution of confining energies as well as to the strength of the applied field

  15. Donor insemination: eugenic and feminist implications.

    Science.gov (United States)

    Hanson, F A

    2001-09-01

    One concern regarding developments in genetics is that, when techniques such as genetic engineering become safe and affordable, people will use them for positive eugenics: to "improve" their offspring by enpowering them with exceptional qualities. Another is whether new reproductive technologies are being used to improve the condition of women or as the tools of a patriarchal system that appropriates female functions to itself and exploits women to further its own ends. Donor insemination is relevant to both of these issues. The degree to which people have used donor insemination in the past for positive eugenic purposes may give some insight into the likelihood of developing technologies being so used in the future. Donor insemination provides women with the opportunity to reproduce with only the most remote involvement of a man. To what degree do women take advantage of this to liberate themselves from male dominance? Through questionnaires and interviews, women who have used donor insemination disclosed their criteria for selecting sperm donors. The results are analyzed for the prevalence of positive eugenic criteria in the selection process and women's attitudes toward minimizing the male role in reproduction.

  16. Hungary Higher Education Quality Assurance System

    Directory of Open Access Journals (Sweden)

    Che Ru-shan

    2013-07-01

    Full Text Available Higher education quality assurance system has drawn much attention since 1980s. Most countries are committed to build the higher education quality assurance system to meet international standards. Under such an international trend, Hungary also actively promotes higher education reform, and established Hungarian Accreditation Committee and in order to ensure the quality of higher education.

  17. Hospital Quality Systems - working mechanisms unraveled.

    NARCIS (Netherlands)

    Schoten, S. van; Groenewegen, P.; Wagner, C.

    2015-01-01

    Context: Quality systems were implemented in healthcare institutions to assure and improve the quality of care. Despite the fact that all Dutch hospitals have implemented a quality system, incidents persist to surface. How could this be explained? The current research was set out to gain thorough

  18. Medicares Physician Quality Reporting System (PQRS)...

    Data.gov (United States)

    U.S. Department of Health & Human Services — Medicares Physician Quality Reporting System (PQRS) allows providers to report measures of process quality and health outcomes. The authors of Medicares Physician...

  19. Characteristics quality system assurance of university programs

    Directory of Open Access Journals (Sweden)

    Lucian Ion Medar

    2011-03-01

    Full Text Available Quality assurance program of study requires time, dedication, effort, innovative thinking and creativity. Competitive research programs monitored by quality assurance system to create the desired results on the relationship between learning and teaching methods and assessment.

  20. Voltage Quality Improvement Using Solar Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Denisa Galzina

    2015-06-01

    This paper briefly shows the methods of power quality improvement, and then the results of on-site power quality measurements in the grid before and after the connection of the solar photovoltaic system.

  1. Integral system of management quality - company quality assurance

    International Nuclear Information System (INIS)

    Dimitrovski, Aleksandar

    1999-01-01

    Integral System of Management Quality is imposed as a solution which in the future will be applied in the companies more frequently, provoked from the needs for solving management quality, working conditions, ecology, safety at work, way of leaving, etc. (Original)

  2. Resonant tunneling spectroscopy of valley eigenstates on a donor-quantum dot coupled system

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, T., E-mail: t.kobayashi@unsw.edu.au; Heijden, J. van der; House, M. G.; Hile, S. J.; Asshoff, P.; Simmons, M. Y.; Rogge, S. [Centre for Quantum Computation and Communication Technology, University of New South Wales, Sydney 2052 New South Wales (Australia); Gonzalez-Zalba, M. F. [Hitachi Cambridge Laboratory, J. J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Vinet, M. [Université Grenoble-Alpes and CEA, LETI, MINATEC, 38000 Grenoble (France)

    2016-04-11

    We report on electronic transport measurements through a silicon double quantum dot consisting of a donor and a quantum dot. Transport spectra show resonant tunneling peaks involving different valley states, which illustrate the valley splitting in a quantum dot on a Si/SiO{sub 2} interface. The detailed gate bias dependence of double dot transport allows a first direct observation of the valley splitting in the quantum dot, which is controllable between 160 and 240 μeV with an electric field dependence 1.2 ± 0.2 meV/(MV/m). A large valley splitting is an essential requirement for implementing a physical electron spin qubit in a silicon quantum dot.

  3. Nuclear safety and quality systems

    International Nuclear Information System (INIS)

    Kunaj, H.; Tireli, E.

    2002-01-01

    According to ISO 8402:1994 [1] Quality is totality of characteristics of an entity that bear on its ability to satisfy stated and implied needs. According to ISO 9000:2000 [3] Quality is degree to which a set of inherent characteristics fulfils the requirements.(author)

  4. QUALITY MANAGEMENT IN BANKING SYSTEM

    Directory of Open Access Journals (Sweden)

    Micuda Ion Dan

    2009-05-01

    Full Text Available Quality management banking perspective is extremely interesting, from the point of view of the activities specific, and of the permanent area competition improvement. Banks being aware of the quality problems also lead to the appearance and requirement of

  5. Pharmacists' guide to the management of organ donors after brain death.

    Science.gov (United States)

    Korte, Catherine; Garber, Jennifer L; Descourouez, Jillian L; Richards, Katelyn R; Hardinger, Karen

    2016-11-15

    This article reviews organ donor pathophysiology as it relates to medication use with the goal of maximizing the successful procurement and transplantation of donor organs. The number of patients requiring organ transplantation continues to grow, yet organ donation rates remain flat, making it critical to appropriately manage each organ donor in order to ensure viability of all transplantable organs. The care given to one organ donor is tantamount to the care of several transplant recipients. Aggressive donor management ensures that the largest number of organs can be successfully procured and improves the organs' overall quality. Hospital pharmacists are responsible for processing orders and preparing the medications outlined in donor management algorithms developed by their respective medical systems. It is important that pharmacists understand the details of the medications used in these protocols in order to critically evaluate each medication order and appropriately manage the donor. Typical medications used in organ donors after brain death include medications for blood pressure management and fluid resuscitation, medications necessary for electrolyte management, blood products, vasopressors, hormone replacement therapy, antiinfectives, anticoagulants, paralytics, and organ preservation solutions. It is essential to provide optimal pharmacotherapy for each organ donor to ensure organ recovery and donation. Typical medications used in organ donors include agents for blood pressure management and fluid resuscitation, medications necessary for electrolyte management, blood products, vasopressors, hormone replacement therapy, antiinfectives, anticoagulants, paralytics, and organ preservation solutions. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  6. Human Milk Processing: A Systematic Review of Innovative Techniques to Ensure the Safety and Quality of Donor Milk.

    Science.gov (United States)

    Peila, Chiara; Emmerik, Nikki E; Giribaldi, Marzia; Stahl, Bernd; Ruitenberg, Joost E; van Elburg, Ruurd M; Moro, Guido E; Bertino, Enrico; Coscia, Alessandra; Cavallarin, Laura

    2017-03-01

    Pasteurization, performed at 62.5°C for 30 minutes (holder pasteurization), is currently recommended in all international human milk banks guidelines, but it affects some human milk bioactive and nutritive components. The present systematic review is aimed at critically reviewing evidence on the suitability of human milk processing techniques other than holder pasteurization, both thermal and nonthermal, to ensure microbiological safety, and on the effects of these techniques on biologically active donor milk components. A systematic review of English and non-English articles using Medline, PubMed, Embase, SCOPUS, and CAB Abstracts, with no restriction in publication date was performed. Search terms included: human, breast, donor, or banked milk, breastmilk, breast fed, breastfed, breastfeed; HTST, Flash, High Pressure, UV, ultrasonic or nonthermal; process, pasteuris, pasteuriz. Only primary research articles published in peer-reviewed journals were included, providing or not a comparison with holder pasteurized human milk, provided that the pasteurization technique was clearly described, and not intended for domestic use. Additional studies were identified by searching bibliographies of relevant articles. Twenty-six studies were identified as being relevant. Two examined both High Pressure Processing and High-Temperature-Short-Time pasteurization; 10 only examined High Pressure Processing; 10 only examined High-Temperature-Short-Time; 2 articles examined ultraviolet irradiation; 2 articles examined (thermo-)ultrasonic processing. The results indicate that data about safety for microbiological control are still scarce for most of the novel technologies, and that consensus on processing conditions is necessary for nonthermal technologies, before any conclusions on the qualitative and nutritional advantages of these techniques can be drawn.

  7. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    Directory of Open Access Journals (Sweden)

    F. G. Fermoso

    2017-06-01

    Full Text Available Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application.

  8. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    International Nuclear Information System (INIS)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-01-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [es

  9. Aligning Business Process Quality and Information System Quality

    OpenAIRE

    Heinrich, Robert

    2013-01-01

    Business processes and information systems mutually affect each other in non-trivial ways. Frequently, the business process design and the information system design are not well aligned. This means that business processes are designed without taking the information system impact into account, and vice versa. Missing alignment at design time often results in quality problems at runtime, such as large response times of information systems, large process execution times, overloaded information s...

  10. Development of Organ-Specific Donor Risk Indices

    Science.gov (United States)

    Akkina, Sanjeev K.; Asrani, Sumeet K.; Peng, Yi; Stock, Peter; Kim, Ray; Israni, Ajay K.

    2012-01-01

    Due to the shortage of deceased donor organs, transplant centers accept organs from marginal deceased donors, including older donors. Organ-specific donor risk indices have been developed to predict graft survival using various combinations of donor and recipient characteristics. We will review the kidney donor risk index (KDRI) and liver donor risk index (LDRI) and compare and contrast their strengths, limitations, and potential uses. The Kidney Donor Risk Index has a potential role in developing new kidney allocation algorithms. The Liver Donor Risk Index allows for greater appreciation of the importance of donor factors, particularly for hepatitis C-positive recipients; as the donor risk index increases, rates of allograft and patient survival among these recipients decrease disproportionately. Use of livers with high donor risk index is associated with increased hospital costs independent of recipient risk factors, and transplanting livers with high donor risk index into patients with Model for End-Stage Liver Disease scores Donor Risk Index has limited this practice. Significant regional variation in donor quality, as measured by the Liver Donor Risk Index, remains in the United States. We also review other potential indices for liver transplant, including donor-recipient matching and the retransplant donor risk index. While substantial progress has been made in developing donor risk indices to objectively assess donor variables that affect transplant outcomes, continued efforts are warranted to improve these indices to enhance organ allocation policies and optimize allograft survival. PMID:22287036

  11. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    Espana Lopez, M. L.

    2001-01-01

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique [es

  12. Risk of tumor transmission after thoracic allograft transplantation from adult donors with central nervous system neoplasm-A UNOS database study.

    Science.gov (United States)

    Hynes, Conor F; Ramakrishnan, Karthik; Alfares, Fahad A; Endicott, Kendal M; Hammond-Jack, Katrina; Zurakowski, David; Jonas, Richard A; Nath, Dilip S

    2017-04-01

    We analyzed the UNOS database to better define the risk of transmission of central nervous system (CNS) tumors from donors to adult recipients of thoracic organs. Data were procured from the Standard Transplant Analysis and Research dataset files. Donors with CNS tumors were identified, and recipients from these donors comprised the study group (Group I). The remaining recipients of organs from donors who did not have CNS tumors formed the control group (Group II). Incidence of recipient CNS tumors, donor-related malignancies, and overall survival were calculated and compared in addition to multivariable logistic regression. A cohort of 58 314 adult thoracic organ recipients were included, of which 337 received organs from donors who had documented CNS tumors (Group I). None of these recipients developed CNS tumors at a median follow-up of 72 months (IR: 30-130 months). Although overall mortality in terms of the percentage was higher in Group I than Group II (163/320=51% vs 22 123/52 691=42%), Kaplan-Meier curves indicate no significant difference in the time to death between the two groups (P=.92). There is little risk of transmission of the common nonaggressive CNS tumors to recipients of thoracic organs. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. The reliability-quality relationship for quality systems and quality risk management.

    Science.gov (United States)

    Claycamp, H Gregg; Rahaman, Faiad; Urban, Jason M

    2012-01-01

    Engineering reliability typically refers to the probability that a system, or any of its components, will perform a required function for a stated period of time and under specified operating conditions. As such, reliability is inextricably linked with time-dependent quality concepts, such as maintaining a state of control and predicting the chances of losses from failures for quality risk management. Two popular current good manufacturing practice (cGMP) and quality risk management tools, failure mode and effects analysis (FMEA) and root cause analysis (RCA) are examples of engineering reliability evaluations that link reliability with quality and risk. Current concepts in pharmaceutical quality and quality management systems call for more predictive systems for maintaining quality; yet, the current pharmaceutical manufacturing literature and guidelines are curiously silent on engineering quality. This commentary discusses the meaning of engineering reliability while linking the concept to quality systems and quality risk management. The essay also discusses the difference between engineering reliability and statistical (assay) reliability. The assurance of quality in a pharmaceutical product is no longer measured only "after the fact" of manufacturing. Rather, concepts of quality systems and quality risk management call for designing quality assurance into all stages of the pharmaceutical product life cycle. Interestingly, most assays for quality are essentially static and inform product quality over the life cycle only by being repeated over time. Engineering process reliability is the fundamental concept that is meant to anticipate quality failures over the life cycle of the product. Reliability is a well-developed theory and practice for other types of manufactured products and manufacturing processes. Thus, it is well known to be an appropriate index of manufactured product quality. This essay discusses the meaning of reliability and its linkages with quality

  14. The quality analysis system implemented by FRAGEMA

    International Nuclear Information System (INIS)

    Kopff, G.

    1988-01-01

    Systematic statistical processing of measurements and quality control data obtained through manufacturing and conformity inspection is necessary for global knowledge of the fuel quality, which is useful both to the designer and to the manufacturer. For this aim the quality control data management and processing system implemented by FRAGEMA is described and illustrated with examples of the different types of statistical quality reports which are printed out. (orig.)

  15. Recruitment of feces donors among blood donors

    DEFF Research Database (Denmark)

    Dahl Jørgensen, Simon Mark; Erikstrup, Christian; Dinh, Khoa Manh

    2018-01-01

    As the use of fecal microbiota transplantation (FMT) has gained momentum, an increasing need for continuous access to healthy feces donors has developed. Blood donors constitute a healthy subset of the general population and may serve as an appropriate group for recruitment. In this study, we...... investigated the suitability of blood donors as feces donors. In a prospective cohort study, we recruited blood donors onsite at a public Danish blood bank. Following their consent, the blood donors underwent a stepwise screening process: First, blood donors completed an electronic pre-screening questionnaire...... to rule out predisposing risk factors. Second, eligible blood donors had blood and fecal samples examined. Of 155 blood donors asked to participate, 137 (88%) completed the electronic pre-screening questionnaire, 16 declined, and 2 were excluded. Of the 137 donors who completed the questionnaire, 79 (58...

  16. THEORETICAL SPECTRA OF THE AM CANUM VENATICORUM BINARY SYSTEM SDSS J0926+3624: EFFECTS OF IRRADIATION ONTO THE DONOR STAR

    International Nuclear Information System (INIS)

    Sengupta, Sujan; Taam, Ronald E.

    2011-01-01

    Taking into account a range of parameters determined from evolutionary models and available observational data, the detailed non-LTE spectrum for the primary star and the irradiated donor star in the AM Canum Venaticorum system SDSS J0926+3624 are constructed based on the TLUSTY stellar atmosphere code. The combined spectrum of the primary and the donor stars along with a multicolor blackbody spectrum of the accretion disk that reproduces a detailed numerical model is compared to the Sloan Digital Sky Survey optical spectrum of the system. The photometric flux of the primary star inferred from eclipse observations is compared with the synthetic spectrum. The model fit of the two independent observations provides an upper limit on the distance of the system for different effective temperatures of the primary. In addition, an upper limit on the combined flux of the disk and the donor in the infrared region wherein the contribution of the primary is negligible is also determined. It is shown that the spectrum of a sufficiently cool donor can exhibit emission lines due to irradiation from a hot primary and the emission features should be detectable in the infrared even though the contribution of the flux from the disk dominates. Thus, it is pointed out that infrared observations of the system would provide important information on the thermal state of the donor as well as useful insight into the thermal properties of the primary star and the accretion disk.

  17. Quality system and audit of human skin allografts

    International Nuclear Information System (INIS)

    Van Baare, J.

    1999-01-01

    Allograft skin has long been recognised as an important resource in the management of bum wounds. The important issue in skin banking is fust to guarantee safety of human cadaveric donor skin. Second, the quality of the allografts should be assured. The Euro Skin Bank, established in 1976, is located in The Netherlands. Not only in The Netherlands, but in many other (European) countries no specific regulation exists for tissue banking. With respect to skin banking in The Netherlands the Euro Skin Bank requested the government what regulations should be applied on their activities. It was stated in 1994 that human allografl skin should be regarded as a phan-naceutical drug, a magistral preparation. The Euro Skin Bank should therefore be subjected to the guidelines given for the Good Laboraton, Practices and Good Manufacturing Practices to process allogmft skin. Nevertheless, it was in the opinion of the Euro Skin Bank that regulating human tissue as a pharmaceutical drug was not sufficient e.g. no specific regulations for serologic testing of the tissue donor is given, which should be one of the most important issues in tissue banking. Recently the government has published new legislation for tissue banks in The Netherlands: on July I st, 1998, a new legislation was enforced concerning organ and tissue donation and on November I st, 1998, quality requirements for organ and tissue banks are published. The European Community discussed the possibility to bring all animal and human tissues under the Medical Device Directive (MDD). Soon it was proposed not to incorporate viable hw-nan tissue into the MDD. Last year all human tissue was excluded from the MDD. Lack of European regulations has been resulted in national laws, e.g. in The Netherlands, Germany and France. Possibly there might be a more significant role for the European Association of Tissue Banks in the near future for European legislation on tissue banking. In order to have a standard quality system wmch is

  18. Anesthesia Management of Organ Donors.

    Science.gov (United States)

    Xia, Victor W; Braunfeld, Michelle

    2017-09-01

    The shortage of suitable organs is the biggest obstacle for transplants. At present, most organs for transplant in the United States are from donation after neurologic determination of death (brain death). Potential organs for transplant need to maintain their viability during a series of insults, including the original disease, physiologic derangements during the dying process, ischemia, and reperfusion. Proper donor management before, during, and after procurement has potential to increase the number and quality of organs from donors. Anesthesiologists need to understand the physiologic derangements associated with brain death and the updated donor management during the periprocurement period. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Patent office governance and patent system quality

    OpenAIRE

    PICARD, Pierre M.; VAN POTTELSBERGHE DE LA POTTERIE, Bruno

    2011-01-01

    The present paper discusses the role of quality in patent systems from the perspective of patent offices' behavior and organization. After documenting original stylized facts, the paper presents a model in which patent offices set patent fees and the quality level of their examination processes. Various objectives of patent offices' governors are considered. We show that the quality of the patent system is maximal for the patent offices that maximises either the social welfare or its own prof...

  20. Charge separation and carrier dynamics in donor-acceptor heterojunction photovoltaic systems.

    Science.gov (United States)

    Teuscher, Joël; Brauer, Jan C; Stepanov, Andrey; Solano, Alicia; Boziki, Ariadni; Chergui, Majed; Wolf, Jean-Pierre; Rothlisberger, Ursula; Banerji, Natalie; Moser, Jacques-E

    2017-11-01

    Electron transfer and subsequent charge separation across donor-acceptor heterojunctions remain the most important areas of study in the field of third-generation photovoltaics. In this context, it is particularly important to unravel the dynamics of individual ultrafast processes (such as photoinduced electron transfer, carrier trapping and association, and energy transfer and relaxation), which prevail in materials and at their interfaces. In the frame of the National Center of Competence in Research "Molecular Ultrafast Science and Technology," a research instrument of the Swiss National Science Foundation, several groups active in the field of ultrafast science in Switzerland have applied a number of complementary experimental techniques and computational simulation tools to scrutinize these critical photophysical phenomena. Structural, electronic, and transport properties of the materials and the detailed mechanisms of photoinduced charge separation in dye-sensitized solar cells, conjugated polymer- and small molecule-based organic photovoltaics, and high-efficiency lead halide perovskite solar energy converters have been scrutinized. Results yielded more than thirty research articles, an overview of which is provided here.

  1. Donor-specific antibodies require preactivated immune system to harm renal transplant.

    Science.gov (United States)

    Süsal, Caner; Döhler, Bernd; Ruhenstroth, Andrea; Morath, Christian; Slavcev, Antonij; Fehr, Thomas; Wagner, Eric; Krüger, Bernd; Rees, Margaret; Balen, Sanja; Živčić-Ćosić, Stela; Norman, Douglas J; Kuypers, Dirk; Emonds, Marie-Paule; Pisarski, Przemyslaw; Bösmüller, Claudia; Weimer, Rolf; Mytilineos, Joannis; Scherer, Sabine; Tran, Thuong H; Gombos, Petra; Schemmer, Peter; Zeier, Martin; Opelz, Gerhard

    2016-07-01

    It is an unresolved issue why some kidney transplant recipients with pretransplant donor-specific HLA antibodies (DSA) show a high transplant failure rate, whereas in other patients DSA do not harm the graft. We investigated whether help from preactivated T-cells might be necessary for DSA to exert a deleterious effect. The impact of pretransplant DSA and immune activation marker soluble CD30 (sCD30) on 3-year graft survival was analyzed in 385 presensitized kidney transplant recipients. A deleterious influence of pretransplant DSA on graft survival was evident only in patients who were positive for the immune activation marker sCD30. In the absence of sCD30 positivity, 3-year graft survival was virtually identical in patients with or without DSA (83.1±3.9% and 84.3±2.8%, P=0.81). A strikingly lower 3-year graft survival rate of 62.1±6.4% was observed in patients who were both sCD30 and DSA positive (HR 2.92, PsCD30 negative. Pretransplant DSA have a significantly deleterious impact on graft survival only in the presence of high pretransplant levels of the activation marker sCD30. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Charge separation and carrier dynamics in donor-acceptor heterojunction photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Joël Teuscher

    2017-11-01

    Full Text Available Electron transfer and subsequent charge separation across donor-acceptor heterojunctions remain the most important areas of study in the field of third-generation photovoltaics. In this context, it is particularly important to unravel the dynamics of individual ultrafast processes (such as photoinduced electron transfer, carrier trapping and association, and energy transfer and relaxation, which prevail in materials and at their interfaces. In the frame of the National Center of Competence in Research “Molecular Ultrafast Science and Technology,” a research instrument of the Swiss National Science Foundation, several groups active in the field of ultrafast science in Switzerland have applied a number of complementary experimental techniques and computational simulation tools to scrutinize these critical photophysical phenomena. Structural, electronic, and transport properties of the materials and the detailed mechanisms of photoinduced charge separation in dye-sensitized solar cells, conjugated polymer- and small molecule-based organic photovoltaics, and high-efficiency lead halide perovskite solar energy converters have been scrutinized. Results yielded more than thirty research articles, an overview of which is provided here.

  3. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  4. Expert system support and juridical quality

    NARCIS (Netherlands)

    Groothuis, Marga M.; Svensson, Jorgen S.; Breuker, J.; Leenes, R.E.; Winkels, R.

    2000-01-01

    This article discusses the use of expert systems as a means of achieving juridical quality within administrative organisations. Do these systems really improve the quality of decision making and provide the desired guarantees with respect to the correct treatment of clients?

  5. Quality assessment of gamma camera systems

    International Nuclear Information System (INIS)

    Kindler, M.

    1985-01-01

    There are methods and equipment in nuclear medical diagnostics that allow selective visualisation of the functioning of organs or organ systems, using radioactive substances for labelling and demonstration of metabolic processes. Following a previous contribution on fundamentals and systems components of a gamma camera system, the article in hand deals with the quality characteristics of such a system and with practical quality control and its significance for clinical applications. [de

  6. Reverse engineering for quality systems

    International Nuclear Information System (INIS)

    Nolan, A.J.

    1995-01-01

    When the age of software engineering began, many companies were faced with a problem of how to support the older, pre-software-engineering, programs. The techniques of reverse engineering and re-engineering were developed to bridge the gap between the past and the present. Although reverse engineering can be used for generating missing documentation, it can also be used as a means to demonstrate quality in these older programs. This paper presents, in the form of a case study, how Rolls-Royce and Associates Limited addressed the quality issues of reverse engineering and re-engineering. (author)

  7. Interplay between barrier width and height in electron tunneling: photoinduced electron transfer in porphyrin-based donor-bridge-acceptor systems.

    Science.gov (United States)

    Pettersson, Karin; Wiberg, Joanna; Ljungdahl, Thomas; Mårtensson, Jerker; Albinsson, Bo

    2006-01-12

    The rate of electron tunneling in molecular donor-bridge-acceptor (D-B-A) systems is determined both by the tunneling barrier width and height, that is, both by the distance between the donor and acceptor as well as by the energy gap between the donor and bridge moieties. These factors are therefore important to control when designing functional electron transfer systems, such as constructs for photovoltaics, artificial photosynthesis, and molecular scale electronics. In this paper we have investigated a set of D-B-A systems in which the distance and the energy difference between the donor and bridge states (DeltaEDB) are systematically varied. Zinc(II) and gold(III) porphyrins were chosen as electron donor and acceptor because of their suitable driving force for photoinduced electron transfer (-0.9 eV in butyronitrile) and well-characterized photophysics. We have previously shown, in accordance with the superexchange mechanism for electron transfer, that the electron transfer rate is proportional to the inverse of DeltaEDB in a series of zinc/gold porphyrin D-B-A systems with bridges of constant edge to edge distance (19.6 A) and varying DeltaEDB (3900-17 600 cm(-1)). Here, we use the same donor and acceptor but the bridge is shortened or extended giving a set of oligo-p-phenyleneethynylene bridges (OPE) with four different edge to edge distances ranging from 12.7 to 33.4 A. These two sets of D-B-A systems-ZnP-RB-AuP+ and ZnP-nB-AuP+-have one bridge in common, and hence, for the first time both the distance and DeltaEDB dependence of electron transfer can be studied simultaneously in a systematic way.

  8. Development of accounting quality management system

    Directory of Open Access Journals (Sweden)

    Plakhtii T.F.

    2017-08-01

    Full Text Available Accounting organization as one of the types of practical activities at the enterprise involves organization of the process of implementation of various kinds of accounting procedures to ensure meeting needs of the users of accounting information. Therefore, to improve its quality an owner should use tools, methods and procedures that enable to improve the quality of implementation of accounting methods and technology. The necessity of using a quality management system for the improvement of accounting organization at the enterprise is substantiated. The system of accounting quality management is developed and grounded in the context of ISO 9001:2015, which includes such processes as the processes of the accounting system, leadership, planning, and evaluation. On the basis of specification and justification of the set of universal requirements (content requirements, formal requirements the model of the environment of demands for high-quality organization of the computerized accounting system that improves the process of preparing high quality financial statements is developed. In order to improve the system of accounting quality management, to justify the main objectives of its further development, namely elimination of unnecessary characteristics of accounting information, the differences between the current level of accounting information quality and its perfect level are considered; the meeting of new needs of users of accounting information that have not been satisfied yet. The ways of leadership demonstration in the system of accounting quality management of accounting subjects at the enterprise are substantiated. The relationship between the current level of accounting information quality and its perfect level is considered. The possible types of measures aimed at improving the system of accounting quality management are identified. The paper grounds the need to include the principle of proper management in the current set of accounting

  9. Human umbilical cord derived mesenchymal stem cells promote interleukin-17 production from human peripheral blood mononuclear cells of healthy donors and systemic lupus erythematosus patients.

    Science.gov (United States)

    Ren, S; Hu, J; Chen, Y; Yuan, T; Hu, H; Li, S

    2016-03-01

    Inflammation instigated by interleukin (IL)-17-producing cells is central to the development and pathogenesis of several human autoimmune diseases and animal models of autoimmunity. The expansion of IL-17-producing cells from healthy donors is reportedly promoted by mesenchymal stem cells derived from fetal bone marrow. In the present study, human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) were examined for their effects on lymphocytes from healthy donors and from patients with systemic lupus erythematosus (SLE). Significantly higher levels of IL-17 were produced when CD4(+) T cells from healthy donors were co-cultured with hUC-MSCs than those that were cultured alone. Blocking experiments identified that this effect might be mediated partially through prostaglandin E2 (PGE2 ) and IL-1β, without IL-23 involvement. We then co-cultured hUC-MSCs with human CD4(+) T cells from systemic lupus erythematosus patients. Ex-vivo inductions of IL-17 by hUC-MSCs in stimulated lymphocytes were significantly higher in SLE patients than in healthy donors. This effect was not observed for IL-23. Taken together, our results represent that hUC-MSCs can promote the IL-17 production from CD4(+) T cells in both healthy donor and SLE patients. PGE2 and IL-1β might also be partially involved in the promotive effect of hUC-MSCs. © 2015 British Society for Immunology.

  10. Quality assurance tracking and trending system (QATTS)

    International Nuclear Information System (INIS)

    Anderson, W.J.

    1987-01-01

    In 1984, The Philadelphia Electric Company (PECo) Quality Assurance (QA) Division recognized a need to modify the existing quality finding tracking program to generate a nuclear trending program that could detect trends of PECo-initiated findings that were not detectable to a day-to-day observer. Before 1984, each quality organization in PECo had a separate tracking system. An adequate quality trending program demanded that all findings be tracked in a common data base. The Quality Assurance Tracking and Trending System (QATTS) is divided into two parts, an on-line subsystem that provides access to QATTS data via corporate computer data screens and a reports and graphics subsystem that connects commercially available reports and graphic software computer packages to the QATTS data base. The QATTS can be accessed from any terminal connected to the main frame computer at PECo headquarters. The paper discusses the tracking system, report generation, responsible organization commitment tracking system (ROCT), and trending program

  11. Quality system in Malaysian National Tissue Bank

    International Nuclear Information System (INIS)

    Go Boon Thong; Firdaus, M. N.; Abd Rani Shamsudin

    1999-01-01

    Quality System in Malaysian National Tissue Bank is based on the Quality Manual which has been drawn up by the chairman, who is the Dean, School of Medical Sciences. The Quality Manual include general standard for Tissue Banking in University Science of Malaysia which describe and explain a set of general standard similar to the EATB standard. The primary aim of the quality system is to produce a safe and effective tissue graft for successful clinical use and to ensure the safety of tissue bank operators. The Quality Manual also related the role of a Technical Manual, which explain the standard of technical aspect of tissue bank in a Quality Assurance. The safe working environment and Good Laboratory Practice is highlight in Quality System. Documentation of tissue bank activities is the key to the administration to tissue bank. Finally Quality System in tissue banking will never be complete without a Tissue Bank Auditing System which allow the tissue bank coordinator and staff to look into the problem and further enhance the progress of the tissue bank

  12. High-dimensional analysis of the aging immune system: verification of age-associated differences in immune signaling responses in healthy donors.

    Science.gov (United States)

    Longo, Diane M; Louie, Brent; Ptacek, Jason; Friedland, Greg; Evensen, Erik; Putta, Santosh; Atallah, Michelle; Spellmeyer, David; Wang, Ena; Pos, Zoltan; Marincola, Francesco M; Schaeffer, Andrea; Lukac, Suzanne; Railkar, Radha; Beals, Chan R; Cesano, Alessandra; Carayannopoulos, Leonidas N; Hawtin, Rachael E

    2014-06-21

    Single-cell network profiling (SCNP) is a multiparametric flow cytometry-based approach that simultaneously measures evoked signaling in multiple cell subsets. Previously, using the SCNP approach, age-associated immune signaling responses were identified in a cohort of 60 healthy donors. In the current study, a high-dimensional analysis of intracellular signaling was performed by measuring 24 signaling nodes in 7 distinct immune cell subsets within PBMCs in an independent cohort of 174 healthy donors [144 elderly (>65 yrs); 30 young (25-40 yrs)]. Associations between age and 9 immune signaling responses identified in the previously published 60 donor cohort were confirmed in the current study. Furthermore, within the current study cohort, 48 additional immune signaling responses differed significantly between young and elderly donors. These associations spanned all profiled modulators and immune cell subsets. These results demonstrate that SCNP, a systems-based approach, can capture the complexity of the cellular mechanisms underlying immunological aging. Further, the confirmation of age associations in an independent donor cohort supports the use of SCNP as a tool for identifying reproducible predictive biomarkers in areas such as vaccine response and response to cancer immunotherapies.

  13. Tank waste remediation system characterization project quality policies

    International Nuclear Information System (INIS)

    Board, D.C.

    1997-01-01

    This quality plan describes the system used by Characterization Project management to achieve quality. This plan is comprised of eleven quality policies which, when taken together, form a management system deployed to achieve quality. This quality management system is based on the customer's quality requirements known as the 'RULE', 10 CFR 830.120, Quality Assurance

  14. Quality label 'Geothermal energy source' (quality-assurance system)

    International Nuclear Information System (INIS)

    Eugster, W. J.

    2005-01-01

    The design of borehole heat exchanger (BHE) plants is covered only marginally through the existing quality labels. And only for small and simple systems. Especially the middle and large sized BHE plants are excluded from the labels. And exactly those plants may be very difficult to treat and to handle. Two concepts of quality control are proposed. On one hand a quality label, which is based on an object sheet, that is both, a planning help and a quality proof. There is no duty for the heating/ventilation/air-conditioning (HVAC) engineers to acquire such a quality label. The label is based on a self quality declaration of the engineers. Therefore a controlling system is needed which induces costs to the labelled engineers. A market penetration of around 20% is predicted for the first three years. The second concept is based on a clear definition of the actual state of the art in designing a BHE plant in a formal standard by the Swiss Engineers and Architects Society (SIA). This concept is proposed for realisation. Nearly 90% of the Swiss BHE drilling market is penetrated by the labelled drilling companies which have agreed to demand from their HVAC engineers (planners) to apply the future SIA standard, either by their general drilling and delivery conditions or by a special agreement. This fact guarantees a fast spreading and application of such a new SIA standard. A collateral information offensive for the HVAC engineers working in the design of BHE plants needs to be stated in any way. This method is not only very cheap but also guarantees a fast and a broad market penetration which must have nearly the same grade as the quality label for drilling companies. But of course, the new standard has to be elaborated first, what should be possible within approximately one year. (author)

  15. [Essential guidelines for Quality Management System].

    Science.gov (United States)

    Daunizeau, A

    2013-06-01

    The guidelines describe the essential parts of the quality management system to fulfil the requirements of the standard EN ISO 15 189. It includes mainly the organisation, the definition of responsibilities, training of personnel, the document control, the quality control, identification and control of nonconformities, corrective actions, preventive actions and evaluation, as audits and the management review.

  16. Five-Star Quality Rating System

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS created the Five-Star Quality Rating System to help consumers, their families, and caregivers compare nursing homes more easily and to help identify areas about...

  17. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  18. Quality Function Deployment for Large Systems

    Science.gov (United States)

    Dean, Edwin B.

    1992-01-01

    Quality Function Deployment (QFD) is typically applied to small subsystems. This paper describes efforts to extend QFD to large scale systems. It links QFD to the system engineering process, the concurrent engineering process, the robust design process, and the costing process. The effect is to generate a tightly linked project management process of high dimensionality which flushes out issues early to provide a high quality, low cost, and, hence, competitive product. A pre-QFD matrix linking customers to customer desires is described.

  19. Influence of Coherent Tunneling and Incoherent Hopping on the Charge Transfer Mechanism in Linear Donor-Bridge-Acceptor Systems.

    Science.gov (United States)

    Li, Guangqi; Govind, Niranjan; Ratner, Mark A; Cramer, Christopher J; Gagliardi, Laura

    2015-12-17

    The mechanism of charge transfer has been observed to change from tunneling to hopping with increasing numbers of DNA base pairs in polynucleotides and with the length of molecular wires. The aim of this paper is to investigate this transition by examining the population dynamics using a tight-binding Hamiltonian with model parameters to describe a linear donor-bridge-acceptor (D-B-A) system. The model includes a primary vibration and an electron-vibration coupling at each site. A further coupling of the primary vibration with a secondary phonon bath allows the system to dissipate energy to the environment and reach a steady state. We apply the quantum master equation (QME) approach, based on second-order perturbation theory in a quantum dissipative system, to examine the dynamical processes involved in charge-transfer and follow the population transfer rate at the acceptor, ka, to shed light on the transition from tunneling to hopping. With a small tunneling parameter, V, the on-site population tends to localize and form polarons, and the hopping mechanism dominates the transfer process. With increasing V, the population tends to be delocalized and the tunneling mechanism dominates. The competition between incoherent hopping and coherent tunneling governs the mechanism of charge transfer. By varying V and the total number of sites, we also examine the onset of the transition from tunneling to hopping with increasing length.

  20. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  1. Dynamical System Modeling to Simulate Donor T Cell Response to Whole Exome Sequencing-Derived Recipient Peptides Demonstrates Different Alloreactivity Potential in HLA-Matched and -Mismatched Donor-Recipient Pairs.

    Science.gov (United States)

    Abdul Razzaq, Badar; Scalora, Allison; Koparde, Vishal N; Meier, Jeremy; Mahmood, Musa; Salman, Salman; Jameson-Lee, Max; Serrano, Myrna G; Sheth, Nihar; Voelkner, Mark; Kobulnicky, David J; Roberts, Catherine H; Ferreira-Gonzalez, Andrea; Manjili, Masoud H; Buck, Gregory A; Neale, Michael C; Toor, Amir A

    2016-05-01

    Immune reconstitution kinetics and subsequent clinical outcomes in HLA-matched recipients of allogeneic stem cell transplantation (SCT) are variable and difficult to predict. Considering SCT as a dynamical system may allow sequence differences across the exomes of the transplant donors and recipients to be used to simulate an alloreactive T cell response, which may allow better clinical outcome prediction. To accomplish this, whole exome sequencing was performed on 34 HLA-matched SCT donor-recipient pairs (DRPs) and the nucleotide sequence differences translated to peptides. The binding affinity of the peptides to the relevant HLA in each DRP was determined. The resulting array of peptide-HLA binding affinity values in each patient was considered as an operator modifying a hypothetical T cell repertoire vector, in which each T cell clone proliferates in accordance with the logistic equation of growth. Using an iterating system of matrices, each simulated T cell clone's growth was calculated with the steady-state population being proportional to the magnitude of the binding affinity of the driving HLA-peptide complex. Incorporating competition between T cell clones responding to different HLA-peptide complexes reproduces a number of features of clinically observed T cell clonal repertoire in the simulated repertoire, including sigmoidal growth kinetics of individual T cell clones and overall repertoire, Power Law clonal frequency distribution, increase in repertoire complexity over time with increasing clonal diversity, and alteration of clonal dominance when a different antigen array is encountered, such as in SCT. The simulated, alloreactive T cell repertoire was markedly different in HLA-matched DRPs. The patterns were differentiated by rate of growth and steady-state magnitude of the simulated T cell repertoire and demonstrate a possible correlation with survival. In conclusion, exome wide sequence differences in DRPs may allow simulation of donor alloreactive T

  2. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  3. Donor Tracker: An Innovative Real-Time Tracking System for Blood ...

    African Journals Online (AJOL)

    User

    According to a research report (Ionut, 2009), smart phones with GPS will increase in number by ... technology for ubiquitous computing systems (Wikipedia). Context-aware .... Figure 5.4.1: Home page of the server-side application. Figure 5.4.2 ...

  4. Tank waste remediation system characterization project quality policies. Revision 1

    International Nuclear Information System (INIS)

    Trimble, D.J.

    1995-01-01

    These Quality Policies (QPs) describe the Quality Management System of the Tank Waste Characterization Project (hereafter referred to as the Characterization Project), Tank Waste Remediation System (TWRS), Westinghouse Hanford Company (WHC). The Quality Policies and quality requirements described herein are binding on all Characterization Project organizations. To achieve quality, the Characterization Project management team shall implement this Characterization Project Quality Management System

  5. Measurement system as a subsystem of the quality management system

    OpenAIRE

    Ľubica Floreková; Ján Terpák; Marcela Čarnogurská

    2006-01-01

    Each measurement system and a control principle must be based on certain facts about the system behaviour (what), operation (how) and structure (why). Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirem...

  6. Measurement system as a subsystem of the quality management system

    Directory of Open Access Journals (Sweden)

    Ľubica Floreková

    2006-12-01

    Full Text Available Each measurement system and a control principle must be based on certain facts about the system behaviour (what, operation (how and structure (why. Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirements defines the measurement, analysis and improvement for each organization in order to present the products conformity, the quality management system conformity guarantee and for the continuously permanent improvement of effectivity, efficiency and economy of quality management system.

  7. Quality assurance system in nuclear engineering

    International Nuclear Information System (INIS)

    Adams, H.W.; Hoensch, V.

    1985-01-01

    Due to the close connection between the German Atomic Energy Law and the nuclear control regulations, quality systems in nuclear engineering have taken on a special form. Quality assurance systems as a stipulated organisation of structure and procedure to assure quality have implications for the organisation of the electric supply company at the planning, erection and commissioning stage and for the organisation of the nuclear power station facility. To supervise the application and effectiveness of the stipulated organisation of structure and procedure internally and externally among contractors, special organisation units have been set up at the plant suppliers, manufactures, electric supply companies and nuclear power station facilities, which in the electric supply field go by the name of Quality Assurance Supervision. (orig.) [de

  8. Quality assurance program for isotopic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Hannigan, R.L.; Harnar, R.R.

    1982-12-01

    This report summarizes the Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators. The program has been implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described in the report and examples of program decumentation are presented.

  9. Quality assurance program for isotopic power systems

    International Nuclear Information System (INIS)

    Hannigan, R.L.; Harnar, R.R.

    1982-12-01

    This report summarizes the Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators. The program has been implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described in the report and examples of program decumentation are presented

  10. Quality assurance systems at SKODA JS

    International Nuclear Information System (INIS)

    Janecek, P.

    2000-01-01

    In addition to technical requirements put upon the design, manufacture, installation and commissioning of equipment for nuclear power plants, emphasis is laid upon quality assurance of such activities so as to secure nuclear safety of installations over the world. As the technical level of nuclear safety assurance is being enhanced continuously, the requirements are becoming more and more stringent, which is mirrored by the relevant standards and legislation. SKODA JS has always been pursuing the quality goal and has been contributing to this aspect markedly. The quality assurance system at SKODA JS helps the company to satisfy all the appropriate requirements of its customers as well as the applicable standards and regulations. (author)

  11. Transmission Quality Measurements in DAB+ Broadcast System

    Directory of Open Access Journals (Sweden)

    Gilski Przemysław

    2017-12-01

    Full Text Available In the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system. We provide a methodology for analysing parameters and factors related with the efficiency and reliability of a digital radio link. We describe a laboratory stand that can be used for transmission quality assessment on a regional and national level.

  12. Voice Quality in Mobile Telecommunication System

    Directory of Open Access Journals (Sweden)

    Evaldas Stankevičius

    2013-05-01

    Full Text Available The article deals with methods measuring the quality of voice transmitted over the mobile network as well as related problem, algorithms and options. It presents the created voice quality measurement system and discusses its adequacy as well as efficiency. Besides, the author presents the results of system application under the optimal hardware configuration. Under almost ideal conditions, the system evaluates the voice quality with MOS 3.85 average estimate; while the standardized TEMS Investigation 9.0 has 4.05 average MOS estimate. Next, the article presents the discussion of voice quality predictor implementation and investigates the predictor using nonlinear and linear prediction methods of voice quality dependence on the mobile network settings. Nonlinear prediction using artificial neural network resulted in the correlation coefficient of 0.62. While the linear prediction method using the least mean squares resulted in the correlation coefficient of 0.57. The analytical expression of voice quality features from the three network parameters: BER, C / I, RSSI is given as well.Article in Lithuanian

  13. Quantifying Quality Aspects of Multimodal Interactive Systems

    CERN Document Server

    Kühnel, Christine

    2012-01-01

    This book systematically addresses the quantification of quality aspects of multimodal interactive systems. The conceptual structure is based on a schematic view on human-computer interaction where the user interacts with the system and perceives it via input and output interfaces. Thus, aspects of multimodal interaction are analyzed first, followed by a discussion of the evaluation of output and input and concluding with a view on the evaluation of a complete system.

  14. Nyretransplantation med levende donor

    DEFF Research Database (Denmark)

    Kamper, A L; Løkkegaard, H; Rasmussen, F

    2000-01-01

    In recent years transplantation from living donors has accounted for 25-30% of all kidney transplants in Denmark corresponding to 40-45 per year. Most of these living donors are parents or siblings, although internationally an increasing number are unrelated donors. Donor nephrectomy is associate...... in cadaver transplantation. The ethical and psychological aspects related to transplantation from a living donor are complex and need to be carefully evaluated when this treatment is offered to the patients....

  15. The integrated system of research quality (quality of the research and research quality

    Directory of Open Access Journals (Sweden)

    M. V. Yurasova

    2014-01-01

    Full Text Available The necessity of the use of research for decision-making on the information received, are considered typical examples of the use of integrated systems research in the practice of the organization, approaches and assess the quality of research and study quality as a subject of study.

  16. Quality system implementation for nuclear analytical techniques

    International Nuclear Information System (INIS)

    2004-01-01

    The international effort (UNIDO, ILAC, BIPM, etc.) to establish a functional infrastructure for metrology and accreditation in many developing countries needs to be complemented by assistance to implement high quality practices and high quality output by service providers and producers in the respective countries. Knowledge of how to approach QA systems that justify a formal accreditation is available in only a few countries and the dissemination of know how and development of skills is needed bottom up from the working level of laboratories and institutes. Awareness building, convincing of management, introduction of good management practices, technical expertise and good documentation will lead to the creation of a quality culture that assures a sustainability and inherent development of quality practices as a prerequisite of economic success. Quality assurance and quality control can be used as a valuable management tool and is a prerequisite for international trade and information exchange. This publication tries to assist quality managers, Laboratory Managers and staff involved in setting up a QA/QC system in a nuclear analytical laboratory to take appropriate action to start and complete the necessary steps for a successful quality system for ultimate national accreditation. This guidebook contributes to a better understanding of the basic ideas behind ISO/IEC 17025, the international standard for 'General requirements for the competence of testing and calibration laboratories'. It provides basic information and detailed explanation about the establishment of the QC system in analytical and nuclear analytical laboratories. It is a proper training material for training of trainers and makes managers with QC management and implementation familiar. This training material aims to facilitate the implementation of internationally accepted quality principles and to promote attempts by Member States' laboratories to obtain accreditation for nuclear analytical

  17. Automated recognition system for power quality disturbances

    Science.gov (United States)

    Abdelgalil, Tarek

    The application of deregulation policies in electric power systems has resulted in the necessity to quantify the quality of electric power. This fact highlights the need for a new monitoring strategy which is capable of tracking, detecting, classifying power quality disturbances, and then identifying the source of the disturbance. The objective of this work is to design an efficient and reliable power quality monitoring strategy that uses the advances in signal processing and pattern recognition to overcome the deficiencies that exist in power quality monitoring devices. The purposed monitoring strategy has two stages. The first stage is to detect, track, and classify any power quality violation by the use of on-line measurements. In the second stage, the source of the classified power quality disturbance must be identified. In the first stage, an adaptive linear combiner is used to detect power quality disturbances. Then, the Teager Energy Operator and Hilbert Transform are utilized for power quality event tracking. After the Fourier, Wavelet, and Walsh Transforms are employed for the feature extraction, two approaches are then exploited to classify the different power quality disturbances. The first approach depends on comparing the disturbance to be classified with a stored set of signatures for different power quality disturbances. The comparison is developed by using Hidden Markov Models and Dynamic Time Warping. The second approach depends on employing an inductive inference to generate the classification rules directly from the data. In the second stage of the new monitoring strategy, only the problem of identifying the location of the switched capacitor which initiates the transients is investigated. The Total Least Square-Estimation of Signal Parameters via Rotational Invariance Technique is adopted to estimate the amplitudes and frequencies of the various modes contained in the voltage signal measured at the facility entrance. After extracting the

  18. Sustainable quality systems for every Health Service

    International Nuclear Information System (INIS)

    Touzet, Rodolfo; Pittaluga, Roberto R.

    2008-01-01

    The implementation of a Quality system is an indispensable requirement to assure the protection and the radiological safety, especially in those facilities where the potential risks are important. One of the 'general conclusions' of the Conference of Malaga (to achieve the RPP) is also the implementation of quality systems. Lamentably the great majority of the Services of Health in the world, more than 95 %, has not nowadays any formal quality system but only any elements what can be named a 'natural quality system' that includes protocols of work, records of several processes, certified of training of the personnel and diverse practices that are realized in systematic form but that not always are documented. Most health services do not have the necessary means available to adhere quickly to international standards. At the same time the health services do not have either qualified or trained personnel to lead a certification or accreditation project and most of them do not have the resources available to hire external consultants, especially the public hospitals. The scenario described represents a challenge for the Regulatory Authorities who must determine 'how to ensure that installations comply with an acceptable standard of quality without it placing an impossible strain on their budget?' Due to these circumstances a 'Basic Guide' has developed for the implementation of a quality system in every Health Service that takes the elements as a foundation of the standard ISO - 9000:2000 and the standard for systems management GSR-3 of the IAEA. The criteria and the methodologies are showed in the presentation. (author)

  19. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....

  20. Reducing replacement donors in Sub-Saharan Africa: challenges and affordability.

    Science.gov (United States)

    Bates, I; Manyasi, G; Medina Lara, A

    2007-12-01

    In 1975, the World Health Assembly recommended that blood for transfusion should come from voluntary, non-remunerated donors; yet, in Africa, 75-80% of blood for transfusion still comes from hospital-based replacement donors. Although comprehensive economic data are scarce, evidence indicates that blood from voluntary donors recruited and screened at centralized transfusion centres, costs four to eight times as much as blood from a hospital-based, replacement donor system. Donor recruitment, quality assurance systems and distribution mechanisms in the centralized system are major reasons for the cost difference. There are concerns about the sustainability of centralized voluntary donor systems and their compatibility with the levels of health care that exist in many poor countries yet burdening patients' families with the responsibility of finding replacement blood donors will exacerbate poverty and reduce the safety of the blood supply. There are measures that can be introduced into hospital-based systems to improve safe blood supply in Africa but their effectiveness in different contexts needs to be evaluated.

  1. Differences in social representation of blood donation between donors and non-donors: an empirical study.

    Science.gov (United States)

    Guarnaccia, Cinzia; Giannone, Francesca; Falgares, Giorgio; Caligaris, Aldo Ozino; Sales-Wuillemin, Edith

    2015-11-04

    Both donors and non-donors have a positive image of blood donation, so donors and non-donors do not differ regarding their views on donation but do differ in converting their opinion into an active deed of donation. Several studies have identified altruism and empathy as the main factors underlying blood donation. However, a mixture of various motivational factors mould the complex behaviour of donation. This paper presents an exploratory study on differences of social representations of blood donation between blood donors and non-donors, in order to understand the reasons that bring someone to take the decision to become a blood donor. Participants filled in the Adapted Self-Report Altruism Scale, Toronto Empathy Questionnaire and answered a test of verbal association. Descriptive and correlation analyses were carried out on quantitative data, while a prototypic analysis was used for qualitative data. The study was carried out on a convenience sample of 786 individuals, 583 donors (mean age: 35.40 years, SD: 13.01 years; 39.3% female) and 203 non-donors (mean age: 35.10 years, SD: 13.30 years; 67.5% female). Social representations of donors seem to be more complex and articulated than those of non-donors. The terms that appear to be central were more specific in donors (life, needle, blood, help, altruism were the words most associated by non-donors; life, aid, altruism, solidarity, health, love, gift, generosity, voluntary, control, needed, useful, needle were the words most associated by donors). Furthermore, non-donors associated a larger number of terms referring to negative aspects of blood donation. Aspects related to training and the accuracy of any information on blood donation seem to be important in the decision to become a donor and stabilise the behaviour of donation over time, thus ensuring the highest levels of quality and safety in blood establishments.

  2. Candida Endophthalmitis After Descemet Stripping Automated Endothelial Keratoplasty With Grafts From Both Eyes of a Donor With Possible Systemic Candidiasis.

    Science.gov (United States)

    Palioura, Sotiria; Sivaraman, Kavitha; Joag, Madhura; Sise, Adam; Batlle, Juan F; Miller, Darlene; Espana, Edgar M; Amescua, Guillermo; Yoo, Sonia H; Galor, Anat; Karp, Carol L

    2018-04-01

    To report 2 cases with late postoperative Candida albicans interface keratitis and endophthalmitis after Descemet stripping automated endothelial keratoplasty (DSAEK) with corneal grafts originating from a single donor with a history of presumed pulmonary candidiasis. Two patients underwent uncomplicated DSAEK by 2 corneal surgeons at different surgery centers but with tissue from the same donor and were referred to the Bascom Palmer Eye Institute with multifocal infiltrates at the graft-host cornea interface 6 to 8 weeks later, and anterior chamber cultures that were positive for the same genetic strain of C. albicans. Immediate explantation of DSAEK lenticules and daily intracameral and instrastromal voriconazole and amphotericin injections failed to control the infection. Thus, both patients underwent therapeutic penetrating keratoplasty with intraocular lens explantation, pars plana vitrectomy, and serial postoperative intraocular antifungal injection. Both patients are doing well at 2 years postoperatively with best-corrected vision of 20/20 and 20/30+ with rigid gas permeable lenses. One patient required repeat optical penetrating keratoplasty and glaucoma tube implantation 1 year after the original surgery. Literature review reveals that donor lenticule explantation and intraocular antifungals are often inadequate to control fungal interface keratitis, and a therapeutic graft is commonly needed. Interface fungal keratitis and endophthalmitis due to infected donor corneal tissue is difficult to treat, and both recipients of grafts originating from the same donor are at risk of developing this challenging condition.

  3. Air quality and future energy system planning

    Science.gov (United States)

    Sobral Mourao, Zenaida; Konadu, Dennis; Lupton, Rick

    2016-04-01

    Ambient air pollution has been linked to an increasing number of premature deaths throughout the world. Projected increases in demand for food, energy resources and manufactured products will likely contribute to exacerbate air pollution with an increasing impact on human health, agricultural productivity and climate change. Current events such as tampering emissions tests by VW car manufacturers, failure to comply with EU Air Quality directives and WHO guidelines by many EU countries, the problem of smog in Chinese cities and new industrial emissions regulations represent unique challenges but also opportunities for regulators, local authorities and industry. However current models and practices of energy and resource use do not consider ambient air impacts as an integral part of the planing process. Furthermore the analysis of drivers, sources and impacts of air pollution is often fragmented, difficult to understand and lacks effective visualization tools that bring all of these components together. This work aims to develop a model that links impacts of air quality on human health and ecosystems to current and future developments in the energy system, industrial and agricultural activity and patterns of land use. The model will be added to the ForeseerTM tool, which is an integrated resource analysis platform that has been developed at the University of Cambridge initially with funding from BP and more recently through the EPSRC funded Whole Systems Energy Modeling (WholeSEM) project. The basis of the tool is a set of linked physical models for energy, water and land, including the technologies that are used to transform these resources into final services such as housing, food, transport and household goods. The new air quality model will explore different feedback effects between energy, land and atmospheric systems with the overarching goal of supporting better communication about the drivers of air quality and to incorporate concerns about air quality into

  4. [Lack of donor organs as an argument for living donors?].

    Science.gov (United States)

    Kirste, G

    2010-09-01

    In Germany more than 12,000 patients are presently waiting for an organ donation. Living donation makes sense for the long waiting time for a kidney, but it is not a permanent solution for the lack of organ donations. In the future topics which should be discussed are intensified public relations, a better family care and the allocation of rights and duties at the German coordinating agency. For all the prospects of success after a living donation the high standards of quality and security, which are targeted by the German donor organization in recipient protection, responsible evaluation of the expanded donor criteria and immunosuppressive therapy are all in favor of post-mortem organ donation. For all the phenomenal chance of success the priority of the post-mortem organ donation is regulated by law. The living donation remains an individual decision of the donor and the personal situation of life.

  5. Quality management system in Nuclear Medicine

    International Nuclear Information System (INIS)

    Peña Tornet, Adela; Torres Aroche, Leonel A.

    2016-01-01

    Establishing Management Systems (QMS) in services Nuclear Medicine (NM) is a prerequisite for optimizing the efficacy and safety of diagnostic and therapeutic procedures of this specialty and increase steadily the quality of the services provide patients. Several international organizations such as the IAEA and scientific specialty societies (SNM, EBNM, etc) and national bodies stimulate and enhance their introduction; in our country is also a requirement of the National Nuclear Safety Centre (CNSN). Are presented in this paper, the main experiences of our country related to the implementation of QMS and developed tools for achieving this goal, such as: The QNUMED automated web environment for managing indicators and documentation format digital; b) The development of prototypes and models for the implementation of the documentation system; d) requirements applying QUANUM in conducting audits of quality management in local services including QUANUM T ool tool; and f) human resource development issues in Quality Management. (author)

  6. Nursing Quality Assurance: The Wisconsin System

    Science.gov (United States)

    Hover, Julie; Zimmer, Marie J.

    1978-01-01

    Evaluation model guidelines for hospital departments of nursing to use in their nursing quality assurance programs are presented as developed in Wisconsin. Four essential components of the Wisconsin outcome evaluation system are criteria, assessment, standards, and improvement of care. Sample tests and charts are included in the article. (MF)

  7. Seed quality in informal seed systems

    NARCIS (Netherlands)

    Biemond, P.C.

    2013-01-01

    Keywords: informal seed systems, seed recycling, seed quality, germination, seed pathology, seed health, seed-borne diseases, mycotoxigenic fungi, Fusarium verticillioides, mycotoxins, Vigna unguiculata, Zea mays, Nigeria.

    Seed is a crucial input for agricultural production.

  8. Quality systems in Dutch health care institutions.

    NARCIS (Netherlands)

    Casparie, A.F.; Sluijs, E.M.; Wagner, C.; Bakker, D.H. de

    1997-01-01

    The implementation of quality systems in Dutch health care was supervised by a national committee during 1990-1995. To monitor the progress of implementation a large survey was conducted in the beginning of 1995. The survey enclosed all subsectors in health care. A postal questionnaire-derived

  9. Groundwater quality mapping using geographic information system ...

    African Journals Online (AJOL)

    Spatial variations in ground water quality in the corporation area of Gulbarga City located in the northern part of Karnataka State, India, have been studied using geographic information system (GIS) technique. GIS, a tool which is used for storing, analyzing and displaying spatial data is also used for investigating ground ...

  10. Environmental impact via quality management system

    International Nuclear Information System (INIS)

    Attia, A.I.A.; EL Nahas, M.M.

    2005-01-01

    Power Quality (PQ) is becoming of great concern to consumers and utilities. Utility companies, equipment manufacturers and electric power customers are the main three parameters who have great interests and growing concern with PQ. Alexandria Electricity Distribution Company (AEDC) is one of the utility company who try to enhance power quality through decreasing disruptions and interruptions which occur by improving the reliability since reliability coupled with power quality and customer service are key components in delivering an effective electricity support to customers which consequently affect the global environment. One strategic solution which has been developed in recent years by AEDC is the Distribution Management System (DMS) that provide remote monitoring of currents, voltages and switch positions of various remote circuit components (direct measurements), control operation and improving the quality of customer service through the reduction of outage time and the monthly detection of reliability indices: System Average Interruption Frequency Index (SAIFI) , System Average Interruption Duration Index (SAIDI), Customer Average Interruption Duration Index (CAIDT) in order To save energy hoping to decrease the global wanning effect and greenhouse gas effect and acid rain phenomena. This paper will cover the effect of DMS on the reliability indices: SAIFI, SAIDI, CAIDI during the last few years and their improvement due to the accuracy of information taken by DMS. In addition, it will discuss the minimization of power losses and their environmental effects on the global warming and greenhouse gas phenomena

  11. The cost-effectiveness of using payment to increase living donor kidneys for transplantation.

    Science.gov (United States)

    Barnieh, Lianne; Gill, John S; Klarenbach, Scott; Manns, Braden J

    2013-12-01

    For eligible candidates, transplantation is considered the optimal treatment compared with dialysis for patients with ESRD. The growing number of patients with ESRD requires new strategies to increase the pool of potential donors. Using decision analysis modeling, this study compared a strategy of paying living kidney donors to waitlisted recipients on dialysis with the current organ donation system. In the base case estimate, this study assumed that the number of donors would increase by 5% with a payment of $10,000. Quality of life estimates, resource use, and costs (2010 Canadian dollars) were based on the best available published data. Compared with the current organ donation system, a strategy of increasing the number of kidneys for transplantation by 5% by paying living donors $10,000 has an incremental cost-savings of $340 and a gain of 0.11 quality-adjusted life years. Increasing the number of kidneys for transplantation by 10% and 20% would translate into incremental cost-savings of $1640 and $4030 and incremental quality-adjusted life years gain of 0.21 and 0.39, respectively. Although the impact is uncertain, this model suggests that a strategy of paying living donors to increase the number of kidneys available for transplantation could be cost-effective, even with a transplant rate increase of only 5%. Future work needs to examine the feasibility, legal policy, ethics, and public perception of a strategy to pay living donors.

  12. Dengue antibodies in blood donors.

    Science.gov (United States)

    Ribas-Silva, Rejane Cristina; Eid, Andressa Ahmad

    2012-01-01

    Dengue is an urban arbovirus whose etiologic agent is a virus of the genus Flavorius with four distinct antigen serotypes (DENV-1, DENV-2, DENV-3 and DENV-4) that is transmitted to humans through the bite of the mosquito Aedes aegypti. The Campo Mourão region in Brazil is endemic for dengue fever. OBTECTIVE: The aim of this study was to evaluate the presence of IgG and IgM antibodies specific to the four serotypes of dengue in donors of the blood donor service in the city of Campo Mourão. Epidemiological records were evaluated and 4 mL of peripheral blood from 213 blood donors were collected in tubes without anticoagulant. Serum was then obtained and immunochromatographic tests were undertaken (Imuno-Rápido Dengue IgM/IgG(TM)). Individuals involved in the study answered a social and epidemiological questionnaire on data which included age, gender and diagnosis of dengue. Only three (1.4%) of the 213 blood tests were positive for IgG anti-dengue antibodies. No donors with IgM antibody, which identifies acute infection, were identified. The results of the current analysis show that the introduction of quantitative or molecular serological methods to determine the presence of anti-dengue antibodies or the detection of the dengue virus in blood donors in endemic regions should be established so that the quality of blood transfusions is guaranteed.

  13. Meet the donors

    DEFF Research Database (Denmark)

    Olejaz, Maria; Hoeyer, Klaus

    2016-01-01

    motivations, but rather as something made meaningful in the light of how donors understand their bodies; their social relations; and their societal position and experiences as patients in the healthcare system. The article thus contributes to the field by investigating the nature of the relationship between......For centuries, gross anatomy teaching and anatomical dissection have been fundamental elements in the training of medical doctors and surgeons across the world. Anatomy education and research rely on a stable and reliable supply of bodies in order to take place. Based on qualitative in...

  14. 15 CFR 995.25 - Quality management system.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Quality management system. 995.25... § 995.25 Quality management system. (a) Quality management system for CEVADs. (1) CEVAD shall operate a quality management system, based on ISO 9001-2000 or equivalent, which embraces all elements of the...

  15. A new donor atom system [(SNN)(S)] for the synthesis of neutral oxotechnetium(V) mixed ligand complexes

    International Nuclear Information System (INIS)

    Papadopoulos, M.S.; Pirmettis, I.C.; Spyriounis, D.M.

    1996-01-01

    Oxotechnetium complexes ligated in a 3 + 1 inch fashion yielding TcOL1L2 complexes were prepared. The L1 tridentate ligand binds with a SNN donor set of atoms. L2 corresponds to a monodentate thiol ligand. Representative members of this group of compounds were chemically characterized by NMR and X-ray diffraction

  16. The German quality system for waste repositories

    International Nuclear Information System (INIS)

    Beckmerhagen, I.; Berg, H.P.; Brennecke, P.

    1993-01-01

    The Bundesamt fuer Strahlenschutz (BfS)--Federal Office for Radiation protection--has to guarantee that the requirements resulting from different regulations concerning planning, design, construction, operation and decommissioning of a waste repository are fulfilled. In addition, the results of the safety assessments lead to nuclear-specific requirements on the design of the plant as well as to requirements on the radioactive waste packages intended to be disposed of. Therefore, the implementation of a quality assurance (QA) and quality control (QC) system is an essential task in order to ensure that the designed quality is achieved so that the necessary precaution against damage is taken. In this paper, a detailed description of QA and QC to be applied to the planned Konrad repository as well as the basic principles and the present status of the waste package QC are indicated and discussed

  17. Anti-Inflammatory Oxicams as Multi-donor Ligand Systems: pH- and Solvent-Dependent Coordination Modes of Meloxicam and Piroxicam to Ru and Os.

    Science.gov (United States)

    Aman, Farhana; Hanif, Muhammad; Kubanik, Mario; Ashraf, Adnan; Söhnel, Tilo; Jamieson, Stephen M F; Siddiqui, Waseeq Ahmad; Hartinger, Christian G

    2017-04-06

    The nitrogen- and sulfur-containing 1,2-benzothiazines meloxicam and piroxicam are widely used as nonsteroidal anti-inflammatory drugs. Intrigued by the presence of multiple donor atoms and therefore potentially rich coordination chemistry, we prepared a series of organometallic Ru and Os compounds with meloxicam and piroxicam featuring either as mono- or bidentate ligand systems. The choice of the solvent and the pH value was identified as the critical parameter to achieve selectively mono- or bidentate coordination. The coordination modes were confirmed experimentally by NMR spectroscopy and single crystal X-ray diffraction analysis. Using DFT calculations, it was established that complexes in which meloxicam acts as a bidentate N,O donor are energetically more favorable than coordination as O,O and S,O donor systems. Since meloxicam and piroxicam derivatives have shown anticancer activity in the past, we aimed to compare the complexes with mono- and bidentate ligands on their in vitro anticancer activity. However, stability studies revealed that only the latter complexes were stable in [D 6 ]DMSO/D 2 O (5:95) and therefore no direct comparisons could be made. The meloxicam complexes 1 and 2 showed moderate cytotoxicity, whereas the piroxicam derivatives 5 and 6 were hardly active against the utilized cell lines. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Hemochromatosis Patients as Voluntary Blood Donors

    Directory of Open Access Journals (Sweden)

    Tara E Power

    2004-01-01

    Full Text Available The present study was designed to investigate hemochromatosis patients' suitability as blood donors as well as their perceptions and experience with the current public donation system. Participants were gathered from a list of current hemochromatosis patients (n=120 and members of the Canadian Hemochromatosis Society (n=1000. Of the 1120 surveys mailed out to these groups, 801 surveys were returned completed. The sample respondents had a mean age of 57.44 years (SD=12.73; range 19 to 87 years, and 57% were men. It was found that 20% (160 of the respondents have donated blood since their diagnosis; however, only 12% of the respondents indicated that they use voluntary blood donation as a means of maintaining their iron levels. Forty per cent of the respondents indicated that they had been refused from voluntary donation. Despite the fact that in May 2001 the Canadian Blood Services, in collaboration with the Canadian Hemochromatosis Society, began a promotion campaign to encourage hemochromatosis patients to become voluntary blood donors, the present study found that 15% of the respondents reported having been refused from the voluntary blood donation service due to the diagnosis of hemochromatosis. With respect to quality of life, it was found that individuals who donate blood were generally healthier with respect to physical functioning and bodily pain, however, these findings may indicate that hemochromatosis patients who are healthier are better able to donate at public blood banks, rather than that voluntary blood donation has an effect on the donors' physical functioning over phlebotomy clinic users. These study findings suggest that although there may be other medical factors limiting individuals from donating, hemochromatosis patients are interested in being voluntary blood donors and this potential resource is currently under-used.

  19. Long-term human immune system reconstitution in non-obese diabetic (NOD)-Rag (-)-γ chain (-) (NRG) mice is similar but not identical to the original stem cell donor.

    Science.gov (United States)

    Harris, D T; Badowski, M; Balamurugan, A; Yang, O O

    2013-12-01

    The murine immune system is not necessarily identical to it human counterpart, which has led to the construction of humanized mice. The current study analysed whether or not a human immune system contained within the non-obese diabetic (NOD)-Rag1(null) -γ chain(null) (NRG) mouse model was an accurate representation of the original stem cell donor and if multiple mice constructed from the same donor were similar to one another. To that end, lightly irradiated NRG mice were injected intrahepatically on day 1 of life with purified cord blood-derived CD34(+) stem and progenitor cells. Multiple mice were constructed from each cord blood donor. Mice were analysed quarterly for changes in the immune system, and followed for periods up to 12 months post-transplant. Mice from the same donor were compared directly with each other as well as with the original donor. Analyses were performed for immune reconstitution, including flow cytometry, T cell receptor (TCR) and B cell receptor (BCR) spectratyping. It was observed that NRG mice could be 'humanized' long-term using cord blood stem cells, and that animals constructed from the same cord blood donor were nearly identical to one another, but quite different from the original stem cell donor immune system. © 2013 British Society for Immunology.

  20. Power quality in electric distribution systems

    International Nuclear Information System (INIS)

    Mohamed, A.A.S.

    2005-01-01

    the power quality of the electric system is defined by the constant values of the voltage and frequency, the good value of the power factor close to unity, and balanced three phase voltages and currents. capacitors are widely installed in distribution systems for reactive power compensation to achieve power and energy loss reduction, voltage regulation and system capacity release. the extent of these benefits depends greatly on low the capacitors are placed on the system . the problem of how to place capacitors on the system such that these benefits are achieved and / or maximized against the cost associated with the capacitor placement is termed the general capacitor placement problem.the presented mathematical model has been developed to determine the size, number, and location of fixed capacitor banks that will maximize the saving derived from reduction in peak power and energy loss, and that will minimize the capital and installation costs of capacitors

  1. Software Quality Assurance for Nuclear Safety Systems

    International Nuclear Information System (INIS)

    Sparkman, D R; Lagdon, R

    2004-01-01

    The US Department of Energy has undertaken an initiative to improve the quality of software used to design and operate their nuclear facilities across the United States. One aspect of this initiative is to revise or create new directives and guides associated with quality practices for the safety software in its nuclear facilities. Safety software includes the safety structures, systems, and components software and firmware, support software and design and analysis software used to ensure the safety of the facility. DOE nuclear facilities are unique when compared to commercial nuclear or other industrial activities in terms of the types and quantities of hazards that must be controlled to protect workers, public and the environment. Because of these differences, DOE must develop an approach to software quality assurance that ensures appropriate risk mitigation by developing a framework of requirements that accomplishes the following goals: (sm b ullet) Ensures the software processes developed to address nuclear safety in design, operation, construction and maintenance of its facilities are safe (sm b ullet) Considers the larger system that uses the software and its impacts (sm b ullet) Ensures that the software failures do not create unsafe conditions Software designers for nuclear systems and processes must reduce risks in software applications by incorporating processes that recognize, detect, and mitigate software failure in safety related systems. It must also ensure that fail safe modes and component testing are incorporated into software design. For nuclear facilities, the consideration of risk is not necessarily sufficient to ensure safety. Systematic evaluation, independent verification and system safety analysis must be considered for software design, implementation, and operation. The software industry primarily uses risk analysis to determine the appropriate level of rigor applied to software practices. This risk-based approach distinguishes safety

  2. Quality assurance system in gamma spectrometry laboratory

    International Nuclear Information System (INIS)

    Mielnikow, A.; Michalik, B.; Chalupnik, S.; Lebecka, J.

    1996-01-01

    On basis of guidelines for development of QUALITY SYSTEM for a testing laboratory (European Standard Series EN 45000) a quality assurance system was implemented in gamma spectroscopy laboratory, where routine measurements of natural (mainly Ra-226, Ra-228, Ra-224, K-40) and artificial (mainly Cs-137 and Cs-134) isotopes are performed. We measure a variety of samples, but mainly coal, vaste rock, ashe, deposits, vegetation and air filters. Laboratory of gamma spectroscopy in Central Mining Institute has three HPGe detectors. There is one coaxial detector with 45% relative efficiency, one detector for low energy region and one detector with extended range). We have also two Ge(Li) detectors from former Czechoslovakia. Shielding is made mainly of steel (40 cm) with the interior covered with lead and copper. The electronics and software (Genie-PC) was bought at 'Canberra' and 'Silena'. The paper describes not only the system of quality assurance but also main problems met by its implementation and results of intercomparison measurements. The QAS has been introduced in 1992. In 1993 the Accreditation Certificate of Testing Laboratory for our Laboratory has been obtained from the Polish Bureau of Research and Certification as a fifth laboratory in Poland. (author)

  3. European quality system for tissue banking.

    Science.gov (United States)

    Manyalich, M; Navarro, A; Koller, J; Loty, B; de Guerra, A; Cornu, O; Vabels, G; Fornasari, P M; Costa, A N; Siska, I; Hirn, M; Franz, N; Miranda, B; Kaminski, A; Uhrynowska, I; Van Baare, J; Trias, E; Fernández, C; de By, T; Poniatowski, S; Carbonell, R

    2009-01-01

    The aims of this project were to analyze the factors that influence quality and safety of tissues for transplantation and to develop the method to ensure standards of quality and safety in relation to tissue banking as demanded by European Directive 2004/23/EC and its technical annexes. It is organized in 4 Working Groups, the objectives of each one being focused in a specific area. The Guide of Recommendations for Tissue Banking is structured into 4 parts: (1) quality systems that apply to tissue banking and general quality system requirements, (2) regulatory framework in Europe, (3) standards available, and (4) recommendations of the fundamental quality and safety keypoints. This Working Group handled design of a multinational musculoskeletal tissue registry prototype. This Working Group handled design and validation of a specialized training model structured into online and face-to-face courses. The model was improved with suggestions from students, and 100% certification was obtained. The Guide for Auditing Tissue Establishments provides guidance for auditors, a self-assessment questionnaire, and an audit report form. The effectiveness and sustainability of the outputs were assessed. Both guides are useful for experienced tissue establishments and auditors and also for professionals that are starting in the field. The registry prototype proves it is possible to exchange tissues between establishments throughout Europe. The training model has been effective in educating staff and means having professionals with excellent expertise. Member states could adapt/adopt it. The guides should be updated periodically and perhaps a European organization should take responsibility for this and even create a body of auditors.

  4. Information Support of the Higher Education Quality Management System

    Directory of Open Access Journals (Sweden)

    Murat K. Baymuldin

    2013-01-01

    Full Text Available The article deals with the quality management system (QMS of a university as a combination of organizational structure, procedures, processes and resources needed to implement quality policy with the help of quality planning, management, control and improvement, the need for automated information system of the university quality management system control

  5. Portuguese food composition database quality management system.

    Science.gov (United States)

    Oliveira, L M; Castanheira, I P; Dantas, M A; Porto, A A; Calhau, M A

    2010-11-01

    The harmonisation of food composition databases (FCDB) has been a recognised need among users, producers and stakeholders of food composition data (FCD). To reach harmonisation of FCDBs among the national compiler partners, the European Food Information Resource (EuroFIR) Network of Excellence set up a series of guidelines and quality requirements, together with recommendations to implement quality management systems (QMS) in FCDBs. The Portuguese National Institute of Health (INSA) is the national FCDB compiler in Portugal and is also a EuroFIR partner. INSA's QMS complies with ISO/IEC (International Organization for Standardisation/International Electrotechnical Commission) 17025 requirements. The purpose of this work is to report on the strategy used and progress made for extending INSA's QMS to the Portuguese FCDB in alignment with EuroFIR guidelines. A stepwise approach was used to extend INSA's QMS to the Portuguese FCDB. The approach included selection of reference standards and guides and the collection of relevant quality documents directly or indirectly related to the compilation process; selection of the adequate quality requirements; assessment of adequacy and level of requirement implementation in the current INSA's QMS; implementation of the selected requirements; and EuroFIR's preassessment 'pilot' auditing. The strategy used to design and implement the extension of INSA's QMS to the Portuguese FCDB is reported in this paper. The QMS elements have been established by consensus. ISO/IEC 17025 management requirements (except 4.5) and 5.2 technical requirements, as well as all EuroFIR requirements (including technical guidelines, FCD compilation flowchart and standard operating procedures), have been selected for implementation. The results indicate that the quality management requirements of ISO/IEC 17025 in place in INSA fit the needs for document control, audits, contract review, non-conformity work and corrective actions, and users' (customers

  6. High-Temperature Short-Time Pasteurization System for Donor Milk in a Human Milk Bank Setting

    OpenAIRE

    Diana Escuder-Vieco; Irene Espinosa-Martos; Juan M. Rodríguez; Nieves Corzo; Antonia Montilla; Pablo Siegfried; Carmen R. Pallás-Alonso; Carmen R. Pallás-Alonso; Leónides Fernández

    2018-01-01

    Donor milk is the best alternative for the feeding of preterm newborns when mother's own milk is unavailable. For safety reasons, it is usually pasteurized by the Holder method (62.5°C for 30 min). Holder pasteurization results in a microbiological safe product but impairs the activity of many biologically active compounds such as immunoglobulins, enzymes, cytokines, growth factors, hormones or oxidative stress markers. High-temperature short-time (HTST) pasteurization has been proposed as an...

  7. New international and national standards concerning quality systems

    International Nuclear Information System (INIS)

    Petrick, K.; Reihlen, H.

    1987-01-01

    The history and contents of the latest standards DIN ISO 9000 through DIN ISO 9004 concerning quality systems are outlined. Information is given referring to the establishment of an in-house quality system, and to quality assurance requirements put down in a three-step quality assurance system for contractual purposes. The services available for certification of quality systems by the 'DQS' and legal aspects are mentioned. (HP)

  8. Nonradiative inter- and intramolecular energy transfer from the aromatic donor anisole to a synthesized photoswitchable acceptor system.

    Science.gov (United States)

    Bardhan, Munmun; Bhattacharya, Sudeshna; Misra, Tapas; Mukhopadhyay, Rupa; De, Asish; Chowdhury, Joydeep; Ganguly, Tapan

    2010-02-01

    We report steady state and time resolved fluorescence measurements on acetonitrile (ACN) solutions of the model compounds, energy donor anisole (A) and a photoswitchable acceptor N,N'-1,2-phenylene di-p-tosylamide (B) and the multichromophore (M) where A and B are connected by a spacer containing both rigid triple (acetylenic) and flexible methylene bonds. Both steady state and time correlated single photon counting measurements demonstrate that though intermolecular energy transfer, of Forster type, between the donor and acceptor moieties occurs with rate 10(8)s(-1) but when these two reacting components are linked by a spacer (multichromophore, M) the observed transfer rate ( approximately 10(11)s(-1)) enhances. This seemingly indicates that the imposition of the spacer by inserting a triple bond may facilitate in the propagation of electronic excitation energy through bond. The time resolved fluorescence measurements along with the theoretical predictions using Configuration interaction singles (CIS) method by using 6-31G (d,p) basis set, implemented in the Gaussian package indicate the formations of the two excited conformers of B. The experimental findings made from the steady state and time resolved fluorescence measurements demonstrate that, though two different isomeric species of the acceptor B are formed in the excited singlet states, the prevailing singlet-singlet nonradiative energy transfer route was found from the donor A to the relatively longer-lived isomeric species of B. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  9. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  10. "Power quality system," a new system of quality management for globalization: towards innovation and competitive advantages.

    Science.gov (United States)

    Abdul-Rahman, H; Berawi, M A

    Knowledge Management (KM) addresses the critical issues of organizational adoption, survival and competence in the face of an increasingly changing environment. KM embodies organizational processes that seek a synergistic combination of the data and information processing capabilities of information and communication technologies (ICT), and the creative and innovative capacity of human beings to improve ICT In that role, knowledge management will improve quality management and avoid or minimize losses and weakness that usually come from poor performance as well as increase the competitive level of the company and its ability to survive in the global marketplace. To achieve quality, all parties including the clients, company consultants, contractors, entrepreneurs, suppliers, and the governing bodies (i.e., all involved stake-holders) need to collaborate and commit to achieving quality. The design based organizations in major business and construction companies have to be quality driven to support healthy growth in today's competitive market. In the march towards vision 2020 and globalization (i.e., the one world community) of many companies, their design based organizations need to have superior quality management and knowledge management to anticipate changes. The implementation of a quality system such as the ISO 9000 Standards, Total Quality Management, or Quality Function Deployment (QFD) focuses the company's resources towards achieving faster and better results in the global market with less cost. To anticipate the needs of the marketplace and clients as the world and technology change, a new system, which we call Power Quality System (PQS), has been designed. PQS is a combination of information and communication technologies (ICT) and the creative and innovative capacity of human beings to meet the challenges of the new world business and to develop high quality products.

  11. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  12. Quality assurance records and records' system

    International Nuclear Information System (INIS)

    Link, M.; Martinek, J.

    1980-01-01

    For nuclear power plants extensive proof of quality is required which has to be documented reliably by quality records. With respect to the paper volume it is the most comprehensive 'curriculum vitae' of the technique. Traditional methods of information and recording are unsatisfactory for meeting regulatory requirements for maintaining the QA-aspects of status reporting, completeness, traceability and retrieval. Therefore KWU has established a record (documentation) subsystem within the overall component qualification system. Examples of the general documentation requirements, the procedure and handling in accordance with this subsystem for mechanical equipment are to be described examplarily. Topics are: - National and international requirements - Definition of QA records - Modular and product orientated KWU-record subsystem - Criteria for developing records - Record control, distribution, collection, storage - New documentation techniques (microfilm, data processing) - Education and training of personnel. (orig./RW)

  13. Being a haematopoietic stem cell donor for a sick sibling: Adult donors' experiences prior to donation.

    Science.gov (United States)

    Kisch, Annika; Bolmsjö, Ingrid; Lenhoff, Stig; Bengtsson, Mariette

    2015-10-01

    There is a lack of knowledge about sibling stem cell donors' experiences pre-donation and the waiting period before the donation might have been long. The donors and their corresponding sibling recipients were simultaneously included in two different interview studies. The results from the recipient study have been presented in a separate paper. The aim was to explore the experiences of being a stem cell donor for a sibling, prior to donation. Ten adult sibling donors were interviewed prior to stem cell donation. The interviews were digitally recorded, transcribed verbatim and subjected to qualitative content analysis. The main theme Being a cog in a big wheel describes the complex process of being a sibling donor prior to donation, covering a mixture of emotions and thoughts. The four subthemes Being available, Being anxious, Being concerned and Being obliged cover the various experiences. The sibling donors' experiences are influenced by the quality of the relationship with the sick sibling. Sibling stem cell donors go through a complex process once they have accidentally got involved in. They have been asked to become a donor; it was not a voluntary choice. In caring for sibling stem cell donors the nurses should be aware of the complexity of the process they experience and take into consideration their personal situation and needs. Providing optimal care for both sibling donors and their corresponding recipients is a challenge, and further improvement and exploration are needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Influence of kinship on donors' mental burden in living donor liver transplantation.

    Science.gov (United States)

    Erim, Yesim; Beckmann, Mingo; Kroencke, Sylvia; Sotiropoulos, Georgios C; Paul, Andreas; Senf, Wolfgang; Schulz, Karl-Heinz

    2012-08-01

    In the context of living donor liver transplantation (LDLT), German transplantation law stipulates that donor candidates should primarily be relatives of the recipients or persons with distinct and close relationships. In this study, we investigated the influence of the relationship between the donor and the recipient on the donor's emotional strain before transplantation. Donors were categorized according to the following subgroups: (1) parents donating for their children, (2) children donating for their parents, (3) siblings, (4) spouses, (5) other relatives, and (6) nonrelatives. The sample consisted of 168 donor candidates. Anxiety (F = 2.8, P = 0.02), depression (F = 2.6, P = 0.03), and emotional quality of life (F = 3.1, P = 0.01) differed significantly according to the relationship between the donor and the recipient. In comparison with healthy controls, parents donating for their children were significantly less stressed before LDLT and demonstrated fewer anxiety (P depression symptoms (P < 0.05). Adult children donating for their parents demonstrated the highest mental burden and the lowest emotional quality of life. However, this was not due to the responsibility of these children for their own families because differences between donors with children and donors without children could not be ascertained. This group should be given special attention before LDLT and during follow-up visits, and psychological help should be provided when it is necessary. Copyright © 2012 American Association for the Study of Liver Diseases.

  15. Quality Improvement and Learning in Productive Systems

    OpenAIRE

    Charles H. Fine

    1986-01-01

    Recent interest in product quality suggests that effort devoted to improving the quality of manufactured products may reduce unit costs. This conjecture---that improving quality can lower costs---challenges the traditional assumption that unit costs increase with increased quality assurance activities and has significant implications for quality management. By introducing the idea of a quality-based learning curve, this paper links the previously disjoint literatures of quality control and le...

  16. Monitoring the LHCb data quality system

    CERN Multimedia

    Baranov, Alexander

    2016-01-01

    Monitoring the quality of the data, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the apparatus during the data taking. DQM at LHCb is carried out in two phase. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs with some delay. For the Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator's task, Monet is also equipped with an automated, fully configurable, alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation.

  17. Quality Rating and Improvement System State Evaluations and Research

    Science.gov (United States)

    Ferguson, Daniel

    2016-01-01

    A quality rating and improvement system (QRIS) is a method used by states and local jurisdictions to assess the level of quality of child care and early education programs, improve quality, and convey quality ratings to parents and other consumers. A typical QRIS incorporates the following components: quality standards for participating providers;…

  18. Agricultural biogas systems. Quality and security

    International Nuclear Information System (INIS)

    Serafimova, K.

    2007-01-01

    This article takes a look at agricultural biogas installations and how improved basic conditions and incentives offered by industry and commerce are showing initial effects. The author is of the opinion that more dynamics in the market are necessary in order to allow contributions to be made to the protection of the climate whilst creating value locally at the same time. The article reviews the current market situation and examines questions which are to be answered in the quality assurance area for agricultural biogas systems in Switzerland. Co-fermentation is proposed as a standard technology. Market development, plant locations and plant management aspects are discussed.

  19. Donor-Derived Myeloid Sarcoma in Two Kidney Transplant Recipients from a Single Donor

    Directory of Open Access Journals (Sweden)

    Amudha Palanisamy

    2015-01-01

    Full Text Available We report the rare occurrence of donor-derived myeloid sarcoma in two kidney transplant patients who received organs from a single deceased donor. There was no evidence of preexisting hematologic malignancy in the donor at the time of organ recovery. Both recipients developed leukemic involvement that appeared to be limited to the transplanted organ. Fluorescence in situ hybridization (FISH and molecular genotyping analyses confirmed that the malignant cells were of donor origin in each patient. Allograft nephrectomy and immediate withdrawal of immunosuppression were performed in both cases; systemic chemotherapy was subsequently administered to one patient. Both recipients were in remission at least one year following the diagnosis of donor-derived myeloid sarcoma. These cases suggest that restoration of the immune system after withdrawal of immunosuppressive therapy and allograft nephrectomy may be sufficient to control HLA-mismatched donor-derived myeloid sarcoma without systemic involvement.

  20. Quality management for space systems in ISRO

    Science.gov (United States)

    Satish, S.; Selva Raju, S.; Nanjunda Swamy, T. S.; Kulkarni, P. L.

    2009-11-01

    In a little over four decades, the Indian Space Program has carved a niche for itself with the unique application driven program oriented towards National development. The end-to-end capability approach of the space projects in the country call for innovative practices and procedures in assuring the quality and reliability of space systems. The System Reliability (SR) efforts initiated at the start of the projects continue during the entire life cycle of the project encompassing design, development, realisation, assembly, testing and integration and during launch. Even after the launch, SR groups participate in the on-orbit evaluation of transponders in communication satellites and camera systems in remote sensing satellites. SR groups play a major role in identification, evaluation and inculcating quality practices in work centres involved in the fabrication of mechanical, electronics and propulsion systems required for Indian Space Research Organization's (ISRO's) launch vehicle and spacecraft projects. Also the reliability analysis activities like prediction, assessment and demonstration as well as de-rating analysis, Failure Mode Effects and Criticality Analysis (FMECA) and worst-case analysis are carried out by SR groups during various stages of project realisation. These activities provide the basis for project management to take appropriate techno-managerial decisions to ensure that the required reliability goals are met. Extensive test facilities catering to the needs of the space program has been set up. A system for consolidating the experience and expertise gained for issue of standards called product assurance specifications to be used in all ISRO centres has also been established.

  1. Water quality diagnosis system for power plant

    International Nuclear Information System (INIS)

    Igarashi, Hiroo; Fukumoto, Toshihiko

    1991-01-01

    An AI diagnose system for the water quality control of a BWR type reactor is divided into a general diagnosing section for generally classifying the water quality conditions of the plant depending on a causal relation between the symptom of the water quality abnormality and its causes, generally diagnosing the position and the cause of the abnormality and ranking the items considered to be the cause, and a detail diagnosing section for a further diagnosis based on the result of the diagnosis in the former section. The general diagnosing section provides a plurality of threshold values showing the extent of the abnormality depending on the cause to the causal relation between the causes and the forecast events previously formed depending on the data of process sensors in the plant. Since the diagnosis for the abnormality and normality is given not only as an ON or OFF mode but also as the extent thereof, it can enter the detailed diagnosis in the most plausible order, based on a plurality of estimated causes, to enable to find the case and take a counter-measure in an early stage. (N.H.)

  2. Technology usage, quality management system, and service quality in Thailand.

    Science.gov (United States)

    Sivabrovornvatana, Nilubon; Siengthai, Sununta; Krairit, Donyaprueth; Paul, Himangshu

    2005-01-01

    This article aims to explore the relationship between technology and quality management for enhancing Thai hospital service quality. The paper presents the findings of an exploratory study that investigates service quality from the customer and service provider perception. In-depth interviews were conducted with respondents in Thai hospitals. The interviews explored service-related factors that patients and service providers perceive to be important for hospital services. The first interview group consisted of professionals as internal customers in direct contact with external customers, while the second group consisted of external customers of the same hospitals. The study's outcomes clearly suggest factors that make significant contribution to service quality. These factors can be categorized according to five SERVQUAL dimensions (reliability, responsiveness, assurance, empathy, and tangibility), although some factors required slightly different interpretation. The findings suggest that hospitals can develop an appropriate approach to their advantage, which can yield sustainable improvement in service quality as perceived by patients and professionals. Hospitals can make better quality decisions based on structured measurement and knowledge. It is recommended that managers apply this knowledge for successful implementation of activities related to service quality in their organizations.

  3. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors

    Science.gov (United States)

    Heim, Albert

    2016-01-01

    Summary Background The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. Methods ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Results Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. Conclusion The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors. PMID:27403089

  4. Evaluation of the Procleix Ultrio Elite Assay and the Panther-System for Individual NAT Screening of Blood, Hematopoietic Stem Cell, Tissue and Organ Donors.

    Science.gov (United States)

    Heim, Albert

    2016-05-01

    The performance of the multiplex Procleix Ultrio Elite assay as individual donor nucleic acid test (ID-NAT) for the detection of HIV-1, HIV-2, HCV, and HBV was evaluated in a retrospective, single center study. ID-NAT results of 21,181 blood donors, 984 tissue donors, 293 hematopoietic stem cell donors and 4 organ donors were reviewed in synopsis with results of serological screening and additional discriminatory and repetitive NAT in case of positive donors. Specificity of the initial Procleix Ultrio Elite assay was 99.98% and after discriminatory testing 100.00%. Initially invalid results were observed in 75 of 21,181 blood donors (0.35%) but 16 of 984 tissue donors (1.62%, p donors. All these had valid negative ID-NAT results after repeated testing or testing of 1:5 diluted specimens in case of tissue donors. Occult hepatitis B (defined here as HBV DNAemia without HBsAg detection) was demonstrated by ID-NAT in two anti-HBc-positive tissue donors and suspected in two other tissue donors, where a definite diagnosis was not achieved due to the insufficient sample volumes available. The Procleix Ultrio Elite assay proved to be specific, robust and rapid. Therefore, routine ID-NAT may also be feasible for organ and granulocyte donors.

  5. Power Quality in DC Power Distribution Systems and Microgrids

    Directory of Open Access Journals (Sweden)

    Stephen Whaite

    2015-05-01

    Full Text Available This review paper discusses power quality considerations for direct current (DC electric power distribution systems, particularly DC microgrids. First, four selected sample DC architectures are discussed to provide motivation for the consideration of power quality in DC systems. Second, a brief overview of power quality challenges in conventional alternating current (AC distribution systems is given to establish the field of power quality. Finally, a survey of literature addressing power quality issues in DC systems is presented, and necessary power quality considerations in DC distribution system design and operation are discussed.

  6. ARCHITECTURE SOFTWARE SOLUTION TO SUPPORT AND DOCUMENT MANAGEMENT QUALITY SYSTEM

    Directory of Open Access Journals (Sweden)

    Milan Eric

    2010-12-01

    Full Text Available One of the basis of a series of standards JUS ISO 9000 is quality system documentation. An architecture of the quality system documentation depends on the complexity of business system. An establishment of an efficient management documentation of system of quality is of a great importance for the business system, as well as in the phase of introducing the quality system and in further stages of its improvement. The study describes the architecture and capability of software solutions to support and manage the quality system documentation in accordance with the requirements of standards ISO 9001:2001, ISO 14001:2005 HACCP etc.

  7. Generation of human induced pluripotent stem cells from urinary cells of a healthy donor using a non-integration system

    OpenAIRE

    Uhm, Kyung-Ok; Jo, Eun Hee; Go, Gue Youn; Kim, So-Jung; Choi, Hye Young; Im, Young Sam; Ha, Hye-Yeong; Jung, Ji-Won; Koo, Soo Kyung

    2017-01-01

    Urinary cells can be an ideal source for generating hiPSCs and progenitors, as they are easily accessible, non-invasive, and universally available. We generated human induced pluripotent stem cells (hiPSCs) from the urinary cells of a healthy donor using a Sendai virus-based gene delivery method. The generated hiPSC line, KSCBi001-A, has a normal karyotype (46,XY). The pluripotency and capacity of multilineage differentiation were characterized by comparison with those of a human embryonic st...

  8. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  9. The Department of Safeguards Quality Management System

    International Nuclear Information System (INIS)

    Konecni, S.

    2015-01-01

    The International Atomic Energy Agency (IAEA) Department of Safeguards quality management system (QMS) provides the framework for all activities that support the Agency's commitment to providing soundly-based safeguards conclusions regarding the peaceful use of nuclear material. The focus of the QMS is to enhance the effectiveness and efficiency of safeguards implementation through defined, documented processes, routine oversight and continual improvement initiatives. In accordance with QMS principles, the high-level business processes representing the Department's activities are defined in procedures, guidelines and policies that are maintained in the Safeguards Document Manager. These processes form the basis for Department operations for drawing safeguards conclusions regarding State's compliance with their safeguards obligations. Oversight is provided through internal quality audits. These audits are targeted at processes selected by Senior Management with a focus on procedure compliance as well as customer expectations. Best practices and areas for improvement are assessed through continual improvement. Noncompliance and conditions that are adverse to quality are identified and analyzed in the Condition Report System. Root cause analysis and the implementation actions to eliminate the cause reduce the chance of condition recurrence. Through continual process improvement, processes are measured and analyzed to reduce process and administration waste. The improved processes improve efficiency while providing the desired results. Within the scope of the QMS, these tools support the performance of Departmental processes so that Safeguards products achieve the intended purpose. This paper describes how the various elements of the Department's QMS support safeguards implementation. (author)

  10. Significance of ISO 9000 Quality Management System for ...

    African Journals Online (AJOL)

    Significance of ISO 9000 Quality Management System for Performance ... of ISO 9000 Quality Management System implementation for performance improvement. ... to find out the relationship between certification and process variability.

  11. Laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Gupta Nitin

    2005-01-01

    Full Text Available Of the various options for patients with end stage renal disease, kidney transplantation is the treatment of choice for a suitable patient. The kidney for transplantation is retrieved from either a cadaver or a live donor. Living donor nephrectomy has been developed as a method to address the shortfall in cadaveric kidneys available for transplantation. Laparoscopic living donor nephrectomy (LLDN, by reducing postoperative pain, shortening convalescence, and improving the cosmetic outcome of the donor nephrectomy, has shown the potential to increase the number of living kidney donations further by removing some of the disincentives inherent to donation itself. The technique of LLDN has undergone evolution at different transplant centers and many modifications have been done to improve donor safety and recipient outcome. Virtually all donors eligible for an open surgical procedure may also undergo the laparoscopic operation. Various earlier contraindications to LDN, such as right donor kidney, multiple vessels, anomalous vasculature and obesity have been overcome with increasing experience. Laparoscopic live donor nephrectomy can be done transperitoneally or retroperitoneally on either side. The approach is most commonly transperitoneal, which allows adequate working space and easy dissection. A review of literature and our experience with regards to standard approach and the modifications is presented including a cost saving model for the developing countries. An assessment has been made, of the impact of LDN on the outcome of donor and the recipient.

  12. Quality management system in hospital radiopharmacy laboratory

    International Nuclear Information System (INIS)

    Poch, Carolina; Rabiller, Graciela; Basualdo, Daniel A.; El Tamer, Elias A.

    2009-01-01

    Objective: 1) To determine the necessary conditions for increasing the complexity of the Radiopharmacy Laboratory and reach an operational level defined by the IAEA as 3a (Operational Guidance on Hospital Radiopharmacy). Our aim is that, within a framework of quality, last generation radiopharmaceuticals can be used, by sophisticated techniques such as labeling with bifunctional chelating agents, like HYNIC; 2) Consequently, we decided to implement a Quality Management System (QMS) in the field of Hospital Radiopharmacy in order to guarantee the safe and effective preparation and handling of radiopharmaceuticals for the diagnosis of patients, based on recommendations of the IAEA. Procedure For the implementation of the QMS, the sector of Radiopharmacy was capacitated in the application of ISO 9001. In a first stage it had begun with the formulation of the main documents and their enumeration. According to the recommendations of the IAEA Operational Guide, this year we proceeded to the optimization of the documents produced in the first stage and formulation of new documents essential to the improvement of work in the Radiopharmacy Laboratory. Results: Corrections were made to the performed procedures, and new ones were composed such as: Reception of raw materials, Control dose calibrator (Activity meter), General procedure of dosage, Procedure for decontamination, for Using the bio safety cabinet, for Cleaning the hot laboratory, etc. The Quality Controls were added to each of the Work Instructions of radiopharmaceuticals to be undertaken and how and when to carry out, with their respective references. Records were modified and new ones incorporated, in order to ensure traceability of the results before and after injection. Finally, the require documentation has been completed with the addition of the Staff Training Plan, and other records such as Nonconformance and Corrective and Preventive Actions. Conclusion: With the application of a QMS correctly implemented

  13. Agroforestry systems and environmental quality: introduction.

    Science.gov (United States)

    Nair, P K Ramachandran

    2011-01-01

    Investments in agroforestry research during the past three decades-albeit modest-have yielded significant gains in understanding the role of trees on farmlands, and the ecological and economic advantages of integrated farming systems. While early research focused mostly on farm or local levels, broader-level ecosystem services of agroforestry systems (AFS) have raised high expectations in recent years. The nine papers included in this special collection deal with three of such environmental benefits of AFS: water-quality enhancement, carbon sequestration, and soil improvement. These benefits are based on the perceived ability of (i) vegetative buffer strips (VBS) to reduce surface transport of agrochemical pollutants, (ii) large volumes of aboveground and belowground biomass of trees to store high amounts of C deeper in the soil profile, and (iii) trees to enhance soil productivity through biological nitrogen fixation, efficient nutrient cycling, and deep capture of nutrients. The papers included have, in general, substantiated these premises and provided new insights. For example, the riparian VBS are reported to increase the reservoir life, in addition to reducing transport of agrochemicals; the variations in C storage in different soil-fraction sizes suggest that microaggregate (250-53 μm) dynamics in the soil could be a good indicator of its C-storage potential; and the use of vector analysis technique is recommended in AFS to avoid consequences of inaccurate and overuse of fertilizers. The papers also identified significant knowledge gaps in these areas. A common theme across all three environmental quality issues covered is that more and varied research datasets across a broad spectrum of conditions need to be generated and integrated with powerful statistical tools to ensure wide applicability of the results. Furthermore, appropriate management practices that are acceptable to the targeted land users and agroforestry practitioners need to be designed to

  14. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  15. Software metrics: Software quality metrics for distributed systems. [reliability engineering

    Science.gov (United States)

    Post, J. V.

    1981-01-01

    Software quality metrics was extended to cover distributed computer systems. Emphasis is placed on studying embedded computer systems and on viewing them within a system life cycle. The hierarchy of quality factors, criteria, and metrics was maintained. New software quality factors were added, including survivability, expandability, and evolvability.

  16. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  17. Computer Algorithms in the Search for Unrelated Stem Cell Donors

    Directory of Open Access Journals (Sweden)

    David Steiner

    2012-01-01

    Full Text Available Hematopoietic stem cell transplantation (HSCT is a medical procedure in the field of hematology and oncology, most often performed for patients with certain cancers of the blood or bone marrow. A lot of patients have no suitable HLA-matched donor within their family, so physicians must activate a “donor search process” by interacting with national and international donor registries who will search their databases for adult unrelated donors or cord blood units (CBU. Information and communication technologies play a key role in the donor search process in donor registries both nationally and internationaly. One of the major challenges for donor registry computer systems is the development of a reliable search algorithm. This work discusses the top-down design of such algorithms and current practice. Based on our experience with systems used by several stem cell donor registries, we highlight typical pitfalls in the implementation of an algorithm and underlying data structure.

  18. Alternative Techniques for Cannulation of Biliary Strictures Resistant to the 0.035 System Following Living Donor Liver Transplantation

    International Nuclear Information System (INIS)

    Yoon, Hee Mang; Kim, Jin Hyoung; Ko, Gi Young; Song, Ho Young; Gwon, Dong Il; Sung, Kyu Bo

    2012-01-01

    To assess the clinical efficacy of alternative techniques for biliary stricture cannulation in patients undergoing living donor liver transplantation (LDLT), after cannulation failure with a conventional (0.035-inch guidewire) technique. Of 293 patients with biliary strictures after LDLT, 19 (6%) patients, 11 men and 8 women of mean age 48.5 years, had the failed cannulation of the stricture by conventional techniques. Recannulation was attempted by using two alternative methods, namely a micro-catheter set via percutaneous access and a snare (rendezvous) technique using percutaneous and endoscopic approaches. Strictures were successfully cannulated in 16 (84%) of the 19 patients. A microcatheter set was used in 12 and a snare technique in four patients. Stricture cannulation failed in the remaining three patients, who finally underwent surgical revision. Most technical failures using a conventional technique for biliary stricture cannulation after LDLT can be overcome by using a microcatheter set or a snare (rendezvous) technique.

  19. Alternative Techniques for Cannulation of Biliary Strictures Resistant to the 0.035 System Following Living Donor Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hee Mang; Kim, Jin Hyoung; Ko, Gi Young; Song, Ho Young; Gwon, Dong Il; Sung, Kyu Bo [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-03-15

    To assess the clinical efficacy of alternative techniques for biliary stricture cannulation in patients undergoing living donor liver transplantation (LDLT), after cannulation failure with a conventional (0.035-inch guidewire) technique. Of 293 patients with biliary strictures after LDLT, 19 (6%) patients, 11 men and 8 women of mean age 48.5 years, had the failed cannulation of the stricture by conventional techniques. Recannulation was attempted by using two alternative methods, namely a micro-catheter set via percutaneous access and a snare (rendezvous) technique using percutaneous and endoscopic approaches. Strictures were successfully cannulated in 16 (84%) of the 19 patients. A microcatheter set was used in 12 and a snare technique in four patients. Stricture cannulation failed in the remaining three patients, who finally underwent surgical revision. Most technical failures using a conventional technique for biliary stricture cannulation after LDLT can be overcome by using a microcatheter set or a snare (rendezvous) technique.

  20. Generation of human induced pluripotent stem cells from urinary cells of a healthy donor using a non-integration system.

    Science.gov (United States)

    Uhm, Kyung-Ok; Jo, Eun Hee; Go, Gue Youn; Kim, So-Jung; Choi, Hye Young; Im, Young Sam; Ha, Hye-Yeong; Jung, Ji-Won; Koo, Soo Kyung

    2017-05-01

    Urinary cells can be an ideal source for generating hiPSCs and progenitors, as they are easily accessible, non-invasive, and universally available. We generated human induced pluripotent stem cells (hiPSCs) from the urinary cells of a healthy donor using a Sendai virus-based gene delivery method. The generated hiPSC line, KSCBi001-A, has a normal karyotype (46,XY). The pluripotency and capacity of multilineage differentiation were characterized by comparison with those of a human embryonic stem cell line. This cell line is registered and available from National Stem Cell Bank, Korea National Institute of Health. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  1. A quality system for PET: An industry perspective

    International Nuclear Information System (INIS)

    Zigler, Steven S.; Breslow, Kenneth; Nazerias, Michael

    2005-01-01

    Quality systems have been employed in a variety of industries to develop and supply products that meet customer expectations and regulatory requirements. Most quality systems address organizational structure, design controls, production, complaints, audits, corrective actions and preventive actions. This paper describes PETNET's efforts to develop a quality system for use in the production of PET tracers. Our goal is to ensure quality products and to facilitate compliance with impending PET good manufacturing practice (GMP) regulations

  2. Donor Telomere Length SAA

    Science.gov (United States)

    A new NCI study has found that, among patients with severe aplastic anemia who received a hematopoietic cell transplant from an unrelated donor, those whose donor white blood cells had longer telomeres had higher survival rates five-years after transplant

  3. Organ donors: deceased or alive? Quo vadis?

    Science.gov (United States)

    Rozental, R

    2006-01-01

    Irrespectively of universal shortage of donor organs there is a tendency of increasing the number of transplantations from living and deceased donors. Each of these two methods has positive and negative features. The main obstacles using living donors are health hazard, necessity to solve certain donor's social and psychological problems, possibility of organ trade and moving. The main problems connected with organ retrieval from deceased donors are possible conflicts with public opinion: difficulties in interpretation of brain death, legislation, obtaining of informed consent from donor's relatives, etc. Future progress in organ transplantation may take place through activation of organ retrieval from deceased donors. The most perspective ways are change to presumed consent in all countries, establishing of centralized system of donor detection and registration, intensification of transplant coordination, active contacts with mass-media, etc. It is necessary to increase (enhance) participation of the members of the public in organ donation process, to develop solidarity among the public members and to involve public authorities to deal with this problem. Bioethical standards should be put in accordance with common progress and some ethical traditions should be changed.

  4. Quality transitivity and traceability system of herbal medicine products based on quality markers.

    Science.gov (United States)

    Liu, Changxiao; Guo, De-An; Liu, Liang

    2018-05-15

    Due to a variety of factors to affect the herb quality, the existing quality management model is unable to evaluate the process control. The development of the concept of "quality marker" (Q-marker) lays basis for establishing an independent process quality control system for herbal products. To ensure the highest degree of safety, effectiveness and quality process control of herbal products, it is aimed to establish a quality transitivity and traceability system of quality and process control from raw materials to finished herbal products. Based on the key issues and challenges of quality assessment, the current status of quality and process controls from raw materials to herbal medicinal products listed in Pharmacopoeia were analyzed and the research models including discovery and identification of Q-markers, analysis and quality management of risk evaluation were designed. Authors introduced a few new technologies and methodologies, such as DNA barcoding, chromatographic technologies, fingerprint analysis, chemical markers, bio-responses, risk management and solution for quality process control. The quality and process control models for herbal medicinal products were proposed and the transitivity and traceability system from raw materials to the finished products was constructed to improve the herbal quality from the entire supply and production chain. The transitivity and traceability system has been established based on quality markers, especially on how to control the production process under Good Engineering Practices, as well as to implement the risk management for quality and process control in herbal medicine production. Copyright © 2018 Elsevier GmbH. All rights reserved.

  5. Trends in organ donor management: 2002 to 2012.

    Science.gov (United States)

    Callahan, Devon S; Kim, Dennis; Bricker, Scott; Neville, Angela; Putnam, Brant; Smith, Jennifer; Bongard, Frederic; Plurad, David

    2014-10-01

    Refinements in donor management have resulted in increased numbers and quality of grafts after neurologic death. We hypothesize that the increased use of hormone replacement therapy (HRT) has been accompanied by improved outcomes over time. Using the Organ Procurement and Transplant Network donor database, all brain-dead donors procured from July 1, 2001 to June 30, 2012 were studied. Hormone replacement therapy was identified by an infusion of thyroid hormone. An expanded criteria donor was defined as age 60 years or older. Incidence of HRT administration and number of donors and organs recovered were calculated. Using the Organ Procurement and Transplant Network thoracic recipient database transplant list, wait times were examined. There were 74,180 brain-dead donors studied. Hormone replacement therapy use increased substantially from 25.6% to 72.3% of donors. However, mean number of organs procured per donor remained static (3.51 to 3.50; p = 0.083), and the rate of high-yield donors decreased (46.4% to 43.1%; p donors decreased (42.1% to 33.9%; p donors (22.1% to 26%). Despite this, there has been an increase in the raw number of donors (20,558 to 24,308; p organs (5,857 to 6,945; p organs per traumatic brain injury donor (4.02 to 4.12; p = 0.002) and a decrease in days on the waiting list (462.2 to 170.4 days; p donors has been accompanied by increased organ availability overall. Potential mechanisms might include successful conversion of previously unacceptable donors and improved recovery in certain subsets of donors. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Production control system specified quality sausage products

    Directory of Open Access Journals (Sweden)

    A. V. Tokarev

    2016-01-01

    Full Text Available The problem of management of production target in technological system of production of sausages of the set quality is considered in article. Decomposition of technological system is considered. Functions of management are allocated: formation of an optimum compounding of forcemeat, expert analysis of a compounding, laboratory analysis of a compounding and its statement. Information technology of interaction of these functions is offered. The mathematical problem definition of finding of an optimum compounding meat product with use of possible substitutes of ingredients is presented. This mathematical problem is a classical linear programming problem whose solution has the standard program. Since the manufacture of the finished product are various nonlinear effects are taken into account at the present time it is practically impossible, the methodology provided in this operation "Expert analysis of the formulation" and "Laboratory analysis of the finished product." An example of calculating the optimum alternative base recipe "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. For an alternative formulation demands were made at a cost of meat, the ingredient composition, as well as the final product organoleptic and physic-chemical indicators should comply with regulatory requirements "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. Indicator acid activity (pH calculated stuffing formulation should be in the range 6.0-6.3. As a partial replacement for the main raw material have been proposed acceptable substitutes. It was necessary to calculate on the basis of the formulation "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002 optimal price and quality alternative formulation. As a result of depreciation of the value of alternative stuffing recipe was 14,5 % when all of the restrictions on the consumer properties. The proposed information technology implemented in the software package "Multi

  7. Successful Reduced Intensity Allogeneic Transplant With Full Donor Chimerism and Good Quality of Life in Adolescent Patient With Wiskott-Aldrich Syndrome.

    Science.gov (United States)

    Ali, Salah; Gacsadi, Anna; McDougall, Elizabeth; Armstrong, Christine; Krueger, Joerg; Schechter, Tal; Ali, Muhammad

    2017-07-01

    Wiskott-Aldrich syndrome (WAS) is an X-linked disease characterized by microthrombocytopenia, eczema, immune deficiency, and autoimmune phenomena. Allogeneic hematopoietic stem cell transplantation (HSCT) is the only curative treatment. Myeloablative conditioning is the most common regimen used for HSCT in patients with WAS to avoid the risk of mixed donor chimerism and autoimmunity post-HSCT. There is limited data on the use of reduced intensity conditioning for HSCT in patients with WAS. Here, we report a case with severe phenotype of WAS transplanted successfully with reduced intensity conditioning, which is an acceptable conditioning regimen and can be considered in patients with WAS with significantly impaired organ functions.

  8. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  9. The main aspects of methodology of quality management system

    Directory of Open Access Journals (Sweden)

    Smirnova E.K.

    2017-03-01

    Full Text Available this article describes the formation and development of quality management as an integrated system. The author considers the theory and methodology of quality management since the early XXth century to the present day and describes the main problems encountered in the process of quality management system, as well as the ways to overcome them.

  10. 14 CFR 60.5 - Quality management system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Quality management system. 60.5 Section 60... requirement of this chapter unless the sponsor has established and follows a quality management system (QMS...) AIRMEN FLIGHT SIMULATION TRAINING DEVICE INITIAL AND CONTINUING QUALIFICATION AND USE § 60.5 Quality...

  11. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  12. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  13. Blood donor deferral: time for change? An evidence-based analysis

    Directory of Open Access Journals (Sweden)

    Borra V

    2016-05-01

    Full Text Available Vere Borra,1 Giovani Vandewalle,1 Hans Van Remoortel,1 Veerle Compernolle,1,2 Emmy De Buck,1 Philippe Vandekerckhove1–31Belgian Red Cross-Flanders, Mechelen, 2Faculty of Medicine, University of Ghent, Ghent, 3Department of Public Health and Primary Care, Faculty of Medicine, KU Leuven, Leuven, BelgiumAbstract: Donor selection remains an important part in the safety of the blood supply all over the world. Yet, donor deferral criteria seem to be strongly based on the precautionary principle protecting safety and quality, and on supply and expense considerations. This review therefore provides an overview of the available evidence on donor exclusion criteria, as well as on their cost-effectiveness, for the most frequent reasons of donor deferral in our region. PubMed was queried to retrieve primary research studies, systematic reviews, and health technology assessments (HTAs concerning donor exclusion criteria. With a similar approach, HTAs about the different blood-banking safety interventions were included. Reasons for donor deferral were recorded via the blood bank information system of the Belgian Red Cross-Flanders. Seven systematic reviews were identified: four on donor safety (hypotension, hypertension/type 2 diabetes, epilepsy, and higher age and three on recipient safety (hemochromatosis, men who have sex with men, and endoscopy. Forty-three low-quality observational studies were included, as well as 16 HTAs: three about donor exclusion criteria and 13 cost-utility analyses about blood-banking safety interventions. In general, the available evidence for deferral reasons was of low quality, and for 60% of the top 30 reasons for excluding donors, no evidence was found. Blood banking shows its unique position as many safety measures far exceed the normally accepted cost of €50,000/quality-adjusted life-years. The historical model based on the precautionary principle and on supply and expense considerations provides adequate supplies of

  14. On chirality transfer in electron donor-acceptor complexes. A prediction for the sulfinimine···BF3 system.

    Science.gov (United States)

    Rode, Joanna E; Dobrowolski, Jan Cz

    2012-01-01

    Stabilization energies of the electron donor-acceptor sulfinimine···BF(3) complexes calculated at either the B3LYP/aug-cc-pVTZ or the MP2/aug-cc-pVTZ level do not allow to judge, whether the N- or O-atom in sulfinimine is stronger electron-donor to BF(3) . The problem seems to be solvable because chirality transfer phenomenon between chiral sulfinimine and achiral BF(3) is expected to be vibrational circular dichroism (VCD) active. Moreover, the bands associated with the achiral BF(3) molecule are predicted to be the most intense in the entire spectrum. However, the VCD band robustness analyses show that most of the chirality transfer modes of BF(3) are unreliable. Conversely, variation of VCD intensity with change of intermolecular distance, angle, and selected dihedrals between the complex partners shows that to establish the robustness of chirality transfer mode. It is also necessary to determine the influence of the potential energy surface (PES) shape on the VCD intensity. At the moment, there is still no universal criterion for the chirality transfer mode robustness and the conclusions formulated based on one system cannot be directly transferred even to a quite similar one. However, it is certain that more attention should be focused on relation of PES shape and the VCD mode robustness problem. Copyright © 2011 Wiley Periodicals, Inc.

  15. Rate dependence of electron transfer on donor-acceptor separation and on free enthalpy change. The Ru(bpy)32+/viologen2+ system

    International Nuclear Information System (INIS)

    Rau, H.; Frank, R.; Greiner, G.

    1986-01-01

    By attachment of hydrocarbon chains of different lengths to the bipyridyl ligands in Ru(bpy) 3 2+ we have adjusted the donor-acceptor separation in the electron-transfer system Ru[(C/sub n/H/sub 2n+1/) 2 bpyl 3 2+ /methylviolgen. Two electron-transfer reactions with different ΔG are investigated in fluid solution: the quenching of the excited complexes by methylviologen (MV 2+ ) which is exergonic with -0.4 eV and the thermal back electron transfer which is exergonic with -1.7 eV. We observe an exponential decrease of the quenching rate on distance. The back electron transfer is independent of donor-acceptor separation; electron transfer is found to take place at distances of 1.5 nm and more. The results are discussed in terms of a hypothesis on the interdependence of transfer distance and free enthalpy change and compared with current theories. In the framework of the simple classical Marcus model, the Marcus equation relating transfer rate and free enthalpy change is transposed into the Rehm-Weller equation by simple mathematical manipulations and the implications of this are discussed

  16. Ex-vivo partial nephrectomy after living donor nephrectomy: Surgical technique for expanding kidney donor pool

    Directory of Open Access Journals (Sweden)

    Yaw A Nyame

    2017-01-01

    Full Text Available Renal transplantation has profound improvements in mortality, morbidity, and overall quality of life compared to renal replacement therapy. This report aims to illustrate the use of ex-vivo partial nephrectomy in a patient with a renal angiomyolipoma prior to living donor transplantation. The surgical outcomes of the donor nephrectomy and recipient transplantation are reported with 2 years of follow-up. Both the donor and recipient are healthy and without any significant comorbidities. In conclusion, urologic techniques such as partial nephrectomy can be used to expand the living donor pool in carefully selected and well informed transplant recipients. Our experience demonstrated a safe and positive outcome for both the recipient and donor, and is consistent with other reported outcomes in the literature.

  17. Magneto-ionic phase control in a quasi-layered donor/acceptor metal-organic framework by means of a Li-ion battery system

    Science.gov (United States)

    Taniguchi, Kouji; Narushima, Keisuke; Yamagishi, Kayo; Shito, Nanami; Kosaka, Wataru; Miyasaka, Hitoshi

    2017-06-01

    Electrical magnetism control is realized in a Li-ion battery system through a redox reaction involving ion migrations; “magneto-ionic control”. A quasi-layered metal-organic framework compound with a cross-linked π-conjugated/unconjugated one-dimensional chain motifs composed of electron-donor/acceptor units is developed as the cathode material. A change in magnetic phase from paramagnetic to ferrimagnetic is demonstrated by means of electron-filling control for the acceptor units via insertion of Li+-ions into pores in the material. The transition temperature is as high as that expected for highly π-conjugated layered systems, indicating an extension of π-conjugated exchange paths by rearranging coordination bonds in the first discharge process.

  18. Influence Business Process On The Quality Of Accounting Information System

    OpenAIRE

    Meiryani; Muhammad Syaifullah

    2015-01-01

    Abstract The purpose of this study was to determine the influence of business process to the quality of the accounting information system. This study aims to examine the influence of business process on the quality of the information system of accounting information system. The study was theoritical research which considered the roles of business process on quality of accounting information system which use secondary data collection. The results showed that the business process have a signifi...

  19. Predictors of Donor Heart Utilization for Transplantation in United States.

    Science.gov (United States)

    Trivedi, Jaimin R; Cheng, Allen; Gallo, Michele; Schumer, Erin M; Massey, H Todd; Slaughter, Mark S

    2017-06-01

    Optimum use of donor organs can increase the reach of the transplantation therapy to more patients on waiting list. The heart transplantation (HTx) has remained stagnant in United States over the past decade at approximately 2,500 HTx annually. With the use of the United Network of Organ Sharing (UNOS) deceased donor database (DCD) we aimed to evaluate donor factors predicting donor heart utilization. UNOS DCD was queried from 2005 to 2014 to identify total number of donors who had at least one of their organs donated. We then generated a multivariate logistic regression model using various demographic and clinical donor factors to predict donor heart use for HTx. Donor hearts not recovered due to consent or family issues or recovered for nontransplantation reasons were excluded from the analysis. During the study period there were 80,782 donors of which 23,606 (29%) were used for HTx, and 38,877 transplants (48%) were not used after obtaining consent because of poor organ function (37%), donor medical history (13%), and organ refused by all programs (5%). Of all, 22,791 donors with complete data were used for logistic regression (13,389 HTx, 9,402 no-HTx) which showed significant predictors of donor heart use for HTx. From this model we assigned probability of donor heart use and identified 3,070 donors with HTx-eligible unused hearts for reasons of poor organ function (28%), organ refused by all programs (15%), and recipient not located (9%). An objective system based on donor factors can predict donor heart use for HTx and may help increase availability of hearts for transplantation from existing donor pool. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Air Quality System (AQS) Monitoring Network, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains points which depict air quality monitors within EPA's Air Quality System (AQS) monitoring network. This dataset is updated weekly to...

  1. Quality Assurance Tracking System - R7 (QATS-R7)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Tracking System - R7, an EPA Region 7 resource that tracks information on quality assurance reviews. Also...

  2. Marginal kidney donor

    Directory of Open Access Journals (Sweden)

    Ganesh Gopalakrishnan

    2007-01-01

    Full Text Available Renal transplantation is the treatment of choice for a medically eligible patient with end stage renal disease. The number of renal transplants has increased rapidly over the last two decades. However, the demand for organs has increased even more. This disparity between the availability of organs and waitlisted patients for transplants has forced many transplant centers across the world to use marginal kidneys and donors. We performed a Medline search to establish the current status of marginal kidney donors in the world. Transplant programs using marginal deceased renal grafts is well established. The focus is now on efforts to improve their results. Utilization of non-heart-beating donors is still in a plateau phase and comprises a minor percentage of deceased donations. The main concern is primary non-function of the renal graft apart from legal and ethical issues. Transplants with living donors outnumbered cadaveric transplants at many centers in the last decade. There has been an increased use of marginal living kidney donors with some acceptable medical risks. Our primary concern is the safety of the living donor. There is not enough scientific data available to quantify the risks involved for such donation. The definition of marginal living donor is still not clear and there are no uniform recommendations. The decision must be tailored to each donor who in turn should be actively involved at all levels of the decision-making process. In the current circumstances, our responsibility is very crucial in making decisions for either accepting or rejecting a marginal living donor.

  3. Influence Business Process On The Quality Of Accounting Information System

    Directory of Open Access Journals (Sweden)

    Meiryani

    2015-01-01

    Full Text Available Abstract The purpose of this study was to determine the influence of business process to the quality of the accounting information system. This study aims to examine the influence of business process on the quality of the information system of accounting information system. The study was theoritical research which considered the roles of business process on quality of accounting information system which use secondary data collection. The results showed that the business process have a significant effect on the quality of accounting information systems.

  4. Quality Assurance System in dental radiology

    International Nuclear Information System (INIS)

    Yacobenco, A.; Tauhata, L.; Infantosi, A.F.

    1998-01-01

    According to data published by the National Commission of Nuclear Energy (CNEN) it was observed that in Dental Radiology more than 80% of the exams reveal entrance skin doses higher than 5,0 mGy, that proximately 85% of the dentists sub-develop the films and 40% of the equipment have low performance regarding collimation, filtration and other problems. This is a critical situation for the population regarding life quality and requires prompt attention from the sanitary authority. Face and universe of 30,000 dentist in the state of Sao Paulo, it was necessary to organize a technical and administrative structure to establish procedures, elaborate training course and create an adequate software system to control all the inspections. The inspection control was based on monitoring the geometrical and exposure parameters as well as the implementation of internal procedures. It was also implemented a control of reject rate and a routine check of the control books. Results show a great improvement of the parameters in 152 of the x ray tubes considered here. Entrance skin dose up to 2,5 mGy increased from 19% to 57%, field size up to 6 cm, increased from 33 % to 96%, k Vp exactitude (13%) and exposure time (67%) jumped to 100%. Also 100% were attained with regards to filtration, collimation and several internal procedures. By the results showed above, we can conclude that we are in the right direction and that all goals will be reached

  5. Total Quality Management of Information System for Quality Assessment of Pesantren Using Fuzzy-SERVQUAL

    Science.gov (United States)

    Faizah, Arbiati; Syafei, Wahyul Amien; Isnanto, R. Rizal

    2018-02-01

    This research proposed a model combining an approach of Total Quality Management (TQM) and Fuzzy method of Service Quality (SERVQUAL) to asses service quality. TQM implementation was as quality management orienting on customer's satisfaction by involving all stakeholders. SERVQUAL model was used to measure quality service based on five dimensions such as tangible, reliability, responsiveness, assurance, and empathy. Fuzzy set theory was to accommodate subjectivity and ambiguity of quality assessment. Input data consisted of indicator data and quality assessment aspect. Input data was, then, processed to be service quality assessment questionnaires of Pesantren by using Fuzzy method to get service quality score. This process consisted of some steps as follows : inputting dimension and questionnaire data to data base system, filling questionnaire through system, then, system calculated fuzzification, defuzzification, gap of quality expected and received by service receivers, and calculating each dimension rating showing quality refinement priority. Rating of each quality dimension was, then, displayed at dashboard system to enable users to see information. From system having been built, it could be known that tangible dimension had the highest gap, -0.399, thus it needs to be prioritized and gets evaluation and refinement action soon.

  6. Cropping system impact on soil quality determinants

    Directory of Open Access Journals (Sweden)

    M. VESTBERG

    2008-12-01

    Full Text Available Worldwide interest in soil quality evaluation has increased rapidly throughout the past decade, prompting us to evaluate the long-term impact of four cropping systems on several biological, chemical and physical determinants of soil quality. We hypothesized that after 17 years several of the determinants would show significant differences between conventional cereal and low input/organic rotations. Four crop rotations were imposed on a silt soil from 1982 through 1999. Rotation A was a conventionally managed cereal rotation that received 100% of the recommended mineral fertilizer each year. Rotation B was also managed conventionally from 1982 until 1993, although it received only 50% of the recommended mineral fertilizer. From 1994 through 1999, rotation B was managed as an organic rotation. Rotations C and D were low-input rotations with plant residues returned either untreated (Cor composted (Dfrom 1982 until 1994.From 1994 through 1999,they were also anaged organically. Significant decreases in extractable phosphorus (Pand potassium were observed in rotations C and D compared with rotation A, presumably because their yearly nutrient inputs were somewhat lower. The amount of soil organic carbon (Corg, soil water holding capacity, the numbers and biomass of earthworms and the microbial biomass carbon and nitrogen were or tended to be higher in low input/organic than in conventionally managed plots. These effects may be in connection with the slightly increased levels of Corg in soil of the organic rotations. Activities of twelve enzymes were strongly affected by sampling time (early-versus late-summer, but much less by long-term management. Litter decomposition, numbers of soil nematodes, arbuscular mycorrhizal (AMfungal diversity,AM spore density and AM functioning were little affected by rotation. However,AM spore density correlated positively with the high amounts of extractable calcium and P which were a result from excessive liming applied

  7. National Marrow Donor Program

    National Research Council Canada - National Science Library

    Setterholm, Michelle

    2008-01-01

    ... a nationwide contingency response plan. 2. Rapid Identification of Matched Donors : Increase operational efficiencies that accelerate the search process and increase patient access are key to preparedness in a contingency event. pa 3...

  8. Fit for purpose quality management system for military forensic exploitation.

    Science.gov (United States)

    Wilson, Lauren Elizabeth; Gahan, Michelle Elizabeth; Robertson, James; Lennard, Chris

    2018-03-01

    In a previous publication we described a systems approach to forensic science applied in the military domain. The forensic science 'system of systems' describes forensic science as a sub-system in the larger criminal justice, law enforcement, intelligence, and military systems, with quality management being an important supporting system. Quality management systems help to ensure that organisations achieve their objective and continually improve their capability. Components of forensic science quality management systems can include standardisation of processes, accreditation of facilities to national/international standards, and certification of personnel. A fit for purpose quality management system should be balanced to allow organisations to meet objectives, provide continuous improvement; mitigate risk; and impart a positive quality culture. Considerable attention over the last decades has been given to the need for forensic science quality management systems to meet criminal justice and law enforcement objectives. More recently, the need for the forensic quality management systems to meet forensic intelligence objectives has been considered. This paper, for the first time, discusses the need for a fit for purpose quality management system for military forensic exploitation. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  9. IMPROVEMENT OF QUALITY ASSURANCE SYSTEM ACTIVITIES OF HIGHER EDUCATION INSTITUTIONS

    Directory of Open Access Journals (Sweden)

    Z. M. Sultalieva

    2016-01-01

    Full Text Available Abstract. The aim of the article is the improvement of quality assessment system of higher education institutions in the aspect of management. The problems of quality improvement are revealed and classified. The analysis of criteria assessment sets used to define the efficiency of higher education institutions activity is carried out. The components of quality of higher education institutions activity are specified. The structural model of quality assessment system of higher education institutions activity is offered. The analysis of macro environment of a university based on the method of strategic management is carried out, i.e. PEST analysis. As a result of the research a new model of macro criteria model of quality assessment system of higher education institutions, characterizing quality management as an approach to university efficiency is offered, moreover, this system can define the level of its competitiveness in the aspect of quality management. 

  10. Implementation of the Quality Management System in the telecommunications companies

    OpenAIRE

    Menshikova Ekaterina; Khazanov Oleg; Styazhkin Mark

    2016-01-01

    This article describes the advantages of the implementing of the quality management system based on ISO 9001 in the telecommunications companies. The stages of the implementation of the quality management system in the telecommunications companies are discussed. The map of the main process and criteria of processes is developed. The expediency of implementing the quality management system based on the requirements of ISO 9001 in Telecommunications is showed.

  11. Influence Business Strategy On The Quality Of Accounting Information System

    OpenAIRE

    Meiryani

    2015-01-01

    Abstract Todaythe survival ofthe companyis largely determinedbythe ability ofcompaniesto competeinthe market so improvement on the quality of accounting information system is needed. Companies use accounting information system as a tool to generate information that managers can make decisions. To be able to take the right decisions necessary quality of accounting information systems. In view of the above this paper considers the Influence Of Business Strategy On The Quality Of Accounting Info...

  12. Methodology and Supporting Toolset Advancing Embedded Systems Quality

    DEFF Research Database (Denmark)

    Berger, Michael Stübert; Soler, José; Brewka, Lukasz Jerzy

    2013-01-01

    Software quality is of primary importance in the development of embedded systems that are often used in safety-critical applications. Moreover, as the life cycle of embedded products becomes increasingly tighter, productivity and quality are simultaneously required and closely interrelated towards...... delivering competitive products. In this context, the MODUS (Methodology and supporting toolset advancing embedded systems quality) project aims to provide a pragmatic and viable solution that will allow SMEs to substantially improve their positioning in the embedded-systems development market. This paper...... will describe the MODUS project with focus on the technical methodologies that will be developed advancing embedded system quality....

  13. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  14. Quality Systems. A Thermodynamics-Related Interpretive Model

    Directory of Open Access Journals (Sweden)

    Stefano A. Lollai

    2017-08-01

    Full Text Available In the present paper, a Quality Systems Theory is presented. Certifiable Quality Systems are treated and interpreted in accordance with a Thermodynamics-based approach. Analysis is also conducted on the relationship between Quality Management Systems (QMSs and systems theories. A measure of entropy is proposed for QMSs, including a virtual document entropy and an entropy linked to processes and organisation. QMSs are also interpreted in light of Cybernetics, and interrelations between Information Theory and quality are also highlighted. A measure for the information content of quality documents is proposed. Such parameters can be used as adequacy indices for QMSs. From the discussed approach, suggestions for organising QMSs are also derived. Further interpretive thermodynamic-based criteria for QMSs are also proposed. The work represents the first attempt to treat quality organisational systems according to a thermodynamics-related approach. At this stage, no data are available to compare statements in the paper.

  15. ASSESSMENT OF POWER QUALITY DISTURBANCE USING EXPERT SYSTEM

    OpenAIRE

    A.N.MALLESWARA RAO,; Dr. K.RAMESH REDDY,; Dr. B.V.SANKER RAM

    2011-01-01

    This paper describes a fuzzy expert system in order to understand and deal with power quality problems encountered in distribution systems in a better way. Because of the technology and software now available this monitoring is highly effective, the fuzzy expert system not only can provide information about the quality of the power and the causes of power system disturbances, but it can identify problem conditions throughout the system before they cause widespread customer complains and equip...

  16. Conceptualising a system for quality clinical decision-making in ...

    African Journals Online (AJOL)

    As a feedback mechanism to promote or improve the quality of clinical decisions in nursing, standards for quality clinical decision-making are proposed in an exemplary manner. In addition, a system for quality clinical decisionmaking in nursing capitalises on the heritage of the nursing process. Considering the changes and ...

  17. Development of a quality management system for Brazilian nuclear installations

    International Nuclear Information System (INIS)

    Kibrit, Eduardo; Zouain, Desiree Moraes

    2005-01-01

    The present work is a proposal for developing a quality management system for Brazilian nuclear installations, based on applicable standards. The standard ISO 9001:2000 [4] establishes general requirements for the implementation of a quality management system in all kinds of organizations. The standard IAEA 50-C/SG-Q [1] establishes general requirements for the implementation of a quality assurance system in nuclear installations. The standard CNEN-NN- 1.16 [5] establishes the regulating requirements for the quality assurance systems and programs of nuclear installations, for licensing and authorization for operation of these installations in Brazil. The revision of standard IAEA 50-C/SG-Q [1], to be replaced by IAEA DS 338 [2] and IAEA DPP 349 [3], introduces the concept of 'Integrated Management System' for the nuclear area, in preference to the concept of 'Quality Assurance'. This approach is incorporated with the current tendency, because it guides the system to manage, in an integrated way, the requirements of quality, safety, health, environment, security and economics of the installation. The results of the characterization of the quality management systems established in the applicable standards are presented, with the determination of the common and conflicting points among them. Referring data to quality assurance program/quality management system in some nuclear installations of IAEA Member States are also presented. (author)

  18. ORIGINAL ARTICLE Quality management systems in radiology

    African Journals Online (AJOL)

    few studies on quality management in radiology have been reported,[4] despite the need for ... organisational framework for the performance of QC tests, evaluation and institution of ... scores passed divided by the total 16 metrics considered.

  19. The EBV Quality Prediction System (EQPS)

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, J.W.J. [German Strategic Petroleum Reserve, Hamburg (Germany)

    1995-05-01

    An oil product is said to be ageing, if over time it changes appearance, performance characteristics or environmental properties. Ageing - and so is quality - is a summary term - embracing many influencing factors and observed behaviours. Ageing quality is a function of inherent or added immunity, environmental factors or exposure and of course age. Inherent factors are themselves a function of raw materials from which the product was made and the manufacturing processes used in the refinery.

  20. Water quality in North American river systems

    International Nuclear Information System (INIS)

    Becker, C.D.; Neitzel, D.A.

    1992-01-01

    This book is about water quality and other characteristics of selected ecosystems in North America. It is also about changes that have occurred in these ecosystems as a result of recent human activities-changes that result primarily from development and exploitation to sustain the needs of an ever-increasing population and the technical innovations that sustain it. Fish populations, hydrology, and water quality control efforts are discussed

  1. The Psychosocial and Independent Living Donor Advocate Evaluation and Post-surgery Care of Living Donors.

    Science.gov (United States)

    Rudow, Dianne LaPointe; Swartz, Kathleen; Phillips, Chelsea; Hollenberger, Jennifer; Smith, Taylor; Steel, Jennifer L

    2015-09-01

    Solid organ transplantation as a treatment for end stage organ failure has been an accepted treatment option for decades. Despite advances in medicine and technology, and increased awareness of organ donation and transplantation, the gap between supply and demand continues to widen. Living donation has been an option that has increased the number of transplants despite the continued shortage of deceased organs. In the early 2000s live donor transplantation reached an all-time high in the United States. As a result, a consensus meeting was convened in 2000 to increase the oversight of living donor transplantation. Both the Centers for Medicare and Medicaid Services and the United Network for Organ Sharing developed regulations that transplant programs performing live donor transplantation. These regulations and guidelines involve the education, evaluation, informed consent process and living donor follow-up care. Two areas in which had significant changes included the psychosocial and the independent living donor advocate (ILDA) evaluation. The purpose of this paper was to outline the current regulations and guidelines associated with the psychosocial and ILDA evaluation as well as provide further recommendations for the administration of a high quality evaluation of living donors. The goals and timing of the evaluation and education of donors; qualifications of the health care providers performing the evaluation; components of the evaluation; education provided to donors; documentation of the evaluation; participation in the selection committee meeting; post-decline and post-donation care of donors is described. Caveats including the paired donor exchange programs and non-directed and directed donation are also considered.

  2. Course Evaluation Systems for Open-ended Quality Enhancement

    DEFF Research Database (Denmark)

    Piihl, Jesper; Rasmussen, Jens Smed

    2013-01-01

    Quality in higher education is widely controlled through surveys asking students to evaluate teaching. However, control of quality does not necessarily lead to enhancement of quality. Drawing on accounting research and a case study, a measurement-based and open-ended quality control system...... emphasising quality enhancement is suggested. The case shows how interactive use of performance measurement can lead to more engaged and enabling dialogue amongst involved actors concerning quality enhancement, however institutionalised beliefs regarding course evaluation systems makes a change challenging....... The chapter suggests that open-ended measurement systems enabling stakeholders to take responsibility for quality enhancement is not so much a matter of technical design as a matter of an enabling style of use....

  3. Live donor transplantation--the incompetent donor: comparative law.

    Science.gov (United States)

    Wolfman, Samuel; Shaked, Tali

    2008-12-01

    Informed consent of the patient to medical treatment is an essential prerequisite for any invasive medical procedure. However in emergency cases, when the patient is unable to sign a consent form due to unconsciousness or to psychotic state, than the primary medical consideration shall take place. In such a case, in order to save life or even prevent a major medical hazard to the patient, doctors are allowed, in certain cases and in accordance with well accepted medical practice, to perform invasive procedures, major surgery or risky pharmacological treatment, without the explicit consent of the patient. All the above refers to the cases when avoidance of such non-consented treatment may harm severely the health and wellbeing of the patient and there is no doubt that such treatment is for the ultimate benefit of the patient. The question, however, shall arise when such a medical procedure is not necessarily for the benefit of the patient, but rather for the benefit of somebody else. Such is the case in the transplantation area and the question of living donor-donee relationship. This paper shall analyze the legal situation in cases of non competent donors whose consent cannot be considered legal consent given in full understanding and out of free will. It will also compare three legal systems, the Israeli, the American and the traditional Jewish law, with regard to the different approaches to this human problem, where the autonomy of the donor may be sacrificed for the purpose of saving life of another person.

  4. Impact of culture on the application of quality management system

    OpenAIRE

    2012-01-01

    M.Ing. The management of quality in companies has become more and more strategically important over recent years. The emphasis on quality is vital to managing projects and achieving excellence in today’s global economy. Modern petrochemical construction project management has incorporated quality management principles and initiatives in their activities. The Quality Management System is used to ensure that the project will satisfy the requirements for which it was undertaken. Improving pro...

  5. Quality-of-data broker for quality-of-data-aware telemedicine systems

    NARCIS (Netherlands)

    Larburu Rubio, Nekane; Bults, Richard G.A.; van Sinderen, Marten J.; Widya, I.A.; Hermens, Hermanus J.

    2016-01-01

    Purpose: Telemedicine systems must provide clinical data of sufficient quality (according to medical standards) to support safe treatment guidance of outpatients. Quality of clinical data (QoD) typically varies due to unstable performance of ICT-components of these telemedicine systems. Therefore,

  6. MR urography for the preoperative evaluation of living renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, Jeannette; Kort, Gerard A.P. de; Lo, Rob; Gils, A.P.G. van; Beek, Frederik J.A. [Department of Radiology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Hene, Ronald J. [Department of Nephrology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Lock, Tycho M.T.W. [Department of and Urology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Burger, Huib [Julius Center for Patient Oriented Research, University of Utrecht, 3584 CX Utrecht (Netherlands)

    2002-08-01

    The purpose of this study was to assess the image quality and diagnostic value of MR urography in detecting abnormalities of the urinary collecting system relevant for the preoperative evaluation of living renal donors. Study subjects were selected from the existing intravenous urography (IVU) reports: 18 consecutive patients with a duplication or another abnormality of the collecting system and 20 consecutive patients with normal anatomy. They underwent a respiratory-triggered 3D T2-weighted fast spin-echo acquisition after oral administration of furosemide, without and with abdominal compression. The MR images were evaluated by two independent blinded observers. The IVU was used as the standard of reference. Image quality of the MR urograms with compression was overall better than those without compression, and the former were regarded as adequate for the evaluation of small filling defects and deformities of the pelvis and calyces in 76-81% of the kidneys and 74-79% of the patients. Both observers correctly diagnosed all 13 kidneys with a partial or complete duplication. The image quality of MR urography was inadequate to evaluate the calyces and pelvis for small filling defects or deformities in approximately 25% of the patients; however, the technique was accurate in the detection of abnormalities of the urinary collecting system relevant for the preoperative evaluation of living renal donors. (orig.)

  7. Effect of Insulin Therapy using Hyper-insulinemic Normoglycemic Clamp on Inflammatory Response in Brain Dead Organ Donors.

    Science.gov (United States)

    Aljiffry, M; Hassanain, M; Schricker, T; Shaheen, M; Nouh, T; Lattermann, R; Salman, A; Wykes, L; Metrakos, P

    2016-05-01

    Brain death is a major stress that is associated with a massive inflammatory response and systemic hyperglycemia. Severe inflammation leads to increased graft immunogenicity and risk of graft dysfunction; while acute hyperglycemia aggravates the inflammatory response and increases the risk of morbidity and mortality. Insulin therapy not only controls hyperglycemia but also suppresses inflammation. The present study is to investigate the anti-inflammatory properties and the normoglycemia maintenance of high dose insulin on brain dead organ donors. 15 brain dead organ donors were divided into 2 groups, insulin treated (n=6) and controls (n=9). Insulin was provided for a minimum of 6 h using the hyperinsulinemic normoglycemic clamp technique. The changes of serum cytokines, including IL-6, IL-10, IL-1β, IL-8, TNFα, TGFα and MCP-1, were measured by suspension bead array immunoassay and glucose by a glucose monitor. Compared to controls, insulin treated donors had a significant lower blood glucose 4.8 (4-6.9) vs. 9 (5.6-11.7) mmol/L, pinsulin treated donors compared with those in controls. High dose insulin therapy decreases the concentrations of inflammatory cytokines in brain dead donors and preserves normoglycemia. High dose of insulin may have anti-inflammatory effects in brain dead organ donors and therefore, improve the quality of donor organs and potentially improve outcomes. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Total Quality Management and the System Safety Secretary

    Science.gov (United States)

    Elliott, Suzan E.

    1993-01-01

    The system safety secretary is a valuable member of the system safety team. As downsizing occurs to meet economic constraints, the Total Quality Management (TQM) approach is frequently adopted as a formula for success and, in some cases, for survival.

  9. Achieving Quality Assurance in Nigeria University System through ...

    African Journals Online (AJOL)

    This paper examines how quality assurance can be attained through Strategic Human Resources Development in Nigerian University system. The purpose is to ensure quality control and maintenance of acceptable standards in the University system. To seek solution to the problem, three research questions were posed.

  10. Particulate fingerprinting of water quality in the distribution system ...

    African Journals Online (AJOL)

    Particles in the distribution system play an important role in the perception? Not clear what is meant) of drinking water quality, particularly in association with discolouration. In The Netherlands the water quality in the distribution system is traditionally monitored by turbidity measurements. However, turbidity is hard to quantify ...

  11. Quality assurance of weather data for agricultural system model input

    Science.gov (United States)

    It is well known that crop production and hydrologic variation on watersheds is weather related. Rarely, however, is meteorological data quality checks reported for agricultural systems model research. We present quality assurance procedures for agricultural system model weather data input. Problems...

  12. 42 CFR 493.1289 - Standard: Analytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Analytic systems quality assessment. 493.1289 Section 493.1289 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND... through 493.1283. (b) The analytic systems quality assessment must include a review of the effectiveness...

  13. 42 CFR 493.1299 - Standard: Postanalytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Postanalytic systems quality assessment. 493.1299 Section 493.1299 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH....1291. (b) The postanalytic systems quality assessment must include a review of the effectiveness of...

  14. 42 CFR 493.1249 - Standard: Preanalytic systems quality assessment.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Preanalytic systems quality assessment. 493.1249 Section 493.1249 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH....1241 through 493.1242. (b) The preanalytic systems quality assessment must include a review of the...

  15. Technical report for effective estimation and improvement of quality system

    International Nuclear Information System (INIS)

    Kim, Kwan Hyun

    2000-06-01

    This technical report provides the methods on how to improve the Quality System, in R and D part. This report applies on the quality assurance(QA) programmes of the design, fabrication in nuclear projects. The organization having overall responsibility for the nuclear power item design, preservation, fabrication shall be described in this report in each stage of improvement of QA systems

  16. An Artificial Intelligence-Based Environment Quality Analysis System

    OpenAIRE

    Oprea , Mihaela; Iliadis , Lazaros

    2011-01-01

    Part 20: Informatics and Intelligent Systems Applications for Quality of Life information Services (ISQLIS) Workshop; International audience; The paper describes an environment quality analysis system based on a combination of some artificial intelligence techniques, artificial neural networks and rule-based expert systems. Two case studies of the system use are discussed: air pollution analysis and flood forecasting with their impact on the environment and on the population health. The syste...

  17. Quality of harvest and role of cell dose in unrelated bone marrow transplantation: an Italian Bone Marrow Donor Registry-Gruppo Italiano Trapianto di Midollo Osseo Study.

    Science.gov (United States)

    Fagioli, Franca; Quarello, Paola; Pollichieni, Simona; Lamparelli, Teresa; Berger, Massimo; Benedetti, Fabio; Barat, Veronica; Marciano, Renato; Rambaldi, Alessandro; Bacigalupo, Andrea; Sacchi, Nicoletta

    2014-01-01

    In this study, we investigated the factors affecting cell dose harvest and the role of cell dose on outcome. We analysed data from a cohort of 703 patients who underwent unrelated bone marrow transplantation facilitated by IBMDR in GITMO centers between 2002 and 2008. The median-infused cell doses is 3.7 × 10(8)/kg, the correlation between the nucleated cells requested from transplant centers and those harvested by collection centers was adequate. A harvested/requested cells ratio lower than 0.5 was observed only in 3% of harvests. A volume of harvested marrow higher than the median value of 1270 ml was related to a significant lower infused cell dose (χ(2): 44.4; P < 0.001). No patient- or donor-related variables significantly influenced the cell dose except for the recipient younger age (χ(2): 95.7; P < 0.001) and non-malignant diseases (χ(2): 33.8; P < 0.001). The cell dose resulted an independent predictor factor for a better outcome in patients affected by non-malignant disease (P = 0.05) while early disease malignant patients receiving a lower cell dose showed a higher risk of relapse (P = 0.05).

  18. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  19. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  20. Motivating medical information system performance by system quality, service quality, and job satisfaction for evidence-based practice

    Science.gov (United States)

    2012-01-01

    Background No previous studies have addressed the integrated relationships among system quality, service quality, job satisfaction, and system performance; this study attempts to bridge such a gap with evidence-based practice study. Methods The convenience sampling method was applied to the information system users of three hospitals in southern Taiwan. A total of 500 copies of questionnaires were distributed, and 283 returned copies were valid, suggesting a valid response rate of 56.6%. SPSS 17.0 and AMOS 17.0 (structural equation modeling) statistical software packages were used for data analysis and processing. Results The findings are as follows: System quality has a positive influence on service quality (γ11= 0.55), job satisfaction (γ21= 0.32), and system performance (γ31= 0.47). Service quality (β31= 0.38) and job satisfaction (β32= 0.46) will positively influence system performance. Conclusions It is thus recommended that the information office of hospitals and developers take enhancement of service quality and user satisfaction into consideration in addition to placing b on system quality and information quality when designing, developing, or purchasing an information system, in order to improve benefits and gain more achievements generated by hospital information systems. PMID:23171394

  1. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    Science.gov (United States)

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Air quality information system for Gauteng

    CSIR Research Space (South Africa)

    Nkuna, J

    2006-10-01

    Full Text Available Air pollution is one of the challenges for sustainable development (Johannesburg being rated fifth worst in the world) One of nine agreed strategies: “Improvement of Air Quality (reduce emissions from vehicles, industry, mines/tailing dams...

  3. Soil quality assessment in rice production systems

    NARCIS (Netherlands)

    Rodrigues de Lima, A.C.

    2007-01-01

    In the state of Rio Grande do Sul, Brazil, rice production is one of the most important regional activities. Farmers are concerned that the land use practices for rice production in the Camaquã region may not be sustainable because of detrimental effects on soil quality. The study presented in this

  4. quality assurance systems in nuclear fuel procurement and manufacturing

    International Nuclear Information System (INIS)

    Can, S.

    1997-01-01

    Quality is the totality of features and characteristics of a product or service that bear on its ability to satisfy stated or implied needs. Quality control is activities and techniques used to fulfill the requirements of quality. Quality assurance is a system and its main components are requirements. QA program, organization and responsibilities, design and verification, material and its control, manufacturing and process control, inspections, audits and documents: manuals, specifications, instructions. Quality assurance systems are largely based on ISO 9000 series of the International Standards Organization. ISO 9000 series has been adopted and published by Turkish Standards Institute as TS-ISO 9000. International Atomic Energy Agency also published a guide (50-SG-QA11) ''Quality Assurance in the Procurement, Design and Manufacture of Nuclear Fuel Assemblies'' in the safety guide series. In this study the role of quality control in quality assurance systems, inspection and test plans and acceptance and nonconformance quality levels will be explained in relation to nuclear fuel production. Examples of applications in quality assurance systems based on ISO 9000 will be given

  5. From technical quality assurance of radiotherapy to a comprehensive quality of service management system

    International Nuclear Information System (INIS)

    Kehoe, T.; Rugg, L.

    1999-01-01

    A hierarchy of dosimetry, planning and machine performance checks and evaluations of clinical outcomes have been widely used in radiotherapy for decades. Procedures, codes of practice and guidance are readily available on the technical aspects of radiotherapy treatments, maintenance of which is achieved by quality control checks within a quality assurance approach to radiotherapy. Recently a series of high profile, well-publicised treatment accidents resulting in damage to patients have focused the attention of both professionals and the public. There is now pressure to introduce formal quality management systems. Patients and their relatives/carers are having their expectations raised but their definition of a quality service differs from that generally considered by the oncology professionals. Most departmental managers and staff have wide experience of quality control checks. They understand the philosophy of quality assurance. However the idea of formal quality systems/quality management is alien to them. What is a professional/departmental manager to do? This paper addresses that question by discussing the underlying principles of quality management covering service provision as well as technical radiotherapy treatment delivery and by providing some guidance based on experience in the practical implementation of quality management through three stages of development: a QA programme incorporating checks on essential parts of the technical treatment delivery, a formal documented certified QA system focusing on technical treatment delivery, a comprehensive quality management system covering all parts of a service. One possible action plan is provided indicating progress through the three stages of development based on experience in one large Radiation Oncology Department. With planning, resources and commitment. a comprehensive quality of service management system is achievable in radiotherapy. (author.)

  6. Kansas Water Quality Action Targeting System (KATS)

    Data.gov (United States)

    Kansas Data Access and Support Center — This system is a revision of the original KATS system developed in 1990 as a tool to aid resource managers target Kansas valuable and vulnerable water resources for...

  7. Quality Management Systems Implementation Compared With Organizational Maturity in Hospital.

    Science.gov (United States)

    Moradi, Tayebeh; Jafari, Mehdi; Maleki, Mohammad Reza; Naghdi, Seyran; Ghiasvand, Hesam

    2015-07-27

    A quality management system can provide a framework for continuous improvement in order to increase the probability of customers and other stakeholders' satisfaction. The test maturity model helps organizations to assess the degree of maturity in implementing effective and sustained quality management systems; plan based on the current realities of the organization and prioritize their improvement programs. We aim to investigate and compare the level of organizational maturity in hospitals with the status of quality management systems implementation. This analytical cross sectional study was conducted among hospital administrators and quality experts working in hospitals with over 200 beds located in Tehran. In the first step, 32 hospitals were selected and then 96 employees working in the selected hospitals were studied. The data were gathered using the implementation checklist of quality management systems and the organization maturity questionnaire derived from ISO 10014. The content validity was calculated using Lawshe method and the reliability was estimated using test - retest method and calculation of Cronbach's alpha coefficient. The descriptive and inferential statistics were used to analyze the data using SPSS 18 software. According to the table, the mean score of organizational maturity among hospitals in the first stage of quality management systems implementation was equal to those in the third stage and hypothesis was rejected (p-value = 0.093). In general, there is no significant difference in the organizational maturity between the first and third level hospitals (in terms of implementation of quality management systems). Overall, the findings of the study show that there is no significant difference in the organizational maturity between the hospitals in different levels of the quality management systems implementation and in fact, the maturity of the organizations cannot be attributed to the implementation of such systems. As a result, hospitals

  8. Power quality in power systems and electrical machines

    CERN Document Server

    Fuchs, Ewald

    2015-01-01

    The second edition of this must-have reference covers power quality issues in four parts, including new discussions related to renewable energy systems. The first part of the book provides background on causes, effects, standards, and measurements of power quality and harmonics. Once the basics are established the authors move on to harmonic modeling of power systems, including components and apparatus (electric machines). The final part of the book is devoted to power quality mitigation approaches and devices, and the fourth part extends the analysis to power quality solutions for renewable

  9. Quality systems in veterinary diagnostics laboratories.

    Science.gov (United States)

    de Branco, Freitas Maia L M

    2007-01-01

    Quality assurance of services provided by veterinary diagnostics laboratories is a fundamental element promoted by international animal health organizations to establish trust, confidence and transparency needed for the trade of animals and their products at domestic and international levels. It requires, among other things, trained personnel, consistent and rigorous methodology, choice of suitable methods as well as appropriate calibration and traceability procedures. An important part of laboratory quality management is addressed by ISO/IEC 17025, which aims to facilitate cooperation among laboratories and their associated parties by assuring the generation of credible and consistent information derived from analytical results. Currently, according to OIE recommendation, veterinary diagnostics laboratories are only subject to voluntary compliance with standard ISO/IEC 17025; however, it is proposed here that OIE reference laboratories and collaboration centres strongly consider its adoption.

  10. Information systems as a quality management tool in clinical laboratories

    Science.gov (United States)

    Schmitz, Vanessa; Rosecler Bez el Boukhari, Marta

    2007-11-01

    This article describes information systems as a quality management tool in clinical laboratories. The quality of laboratory analyses is of fundamental importance for health professionals in aiding appropriate diagnosis and treatment. Information systems allow the automation of internal quality management processes, using standard sample tests, Levey-Jennings charts and Westgard multirule analysis. This simplifies evaluation and interpretation of quality tests and reduces the possibility of human error. This study proposes the development of an information system with appropriate functions and costs for the automation of internal quality control in small and medium-sized clinical laboratories. To this end, it evaluates the functions and usability of two commercial software products designed for this purpose, identifying the positive features of each, so that these can be taken into account during the development of the proposed system.

  11. Information systems as a quality management tool in clinical laboratories

    International Nuclear Information System (INIS)

    Schmitz, Vanessa; Boukhari, Marta Rosecler Bez el

    2007-01-01

    This article describes information systems as a quality management tool in clinical laboratories. The quality of laboratory analyses is of fundamental importance for health professionals in aiding appropriate diagnosis and treatment. Information systems allow the automation of internal quality management processes, using standard sample tests, Levey-Jennings charts and Westgard multirule analysis. This simplifies evaluation and interpretation of quality tests and reduces the possibility of human error. This study proposes the development of an information system with appropriate functions and costs for the automation of internal quality control in small and medium-sized clinical laboratories. To this end, it evaluates the functions and usability of two commercial software products designed for this purpose, identifying the positive features of each, so that these can be taken into account during the development of the proposed system

  12. [Establishment of traceability system of Chinese medicinal materials' quality].

    Science.gov (United States)

    Qi, Yao-dong; Gao, Shi-man; Liu, Hai-tao; Li, Xi-wen; Wei, Jian-he; Zhang, Ben-gang; Sun, Xiao-bo; Xiao, Pei-gen

    2015-12-01

    The quality of Chinese medicinal materials relates greatly to the clinical curative effect and security. In order to ensure the quality and safety of Chinese medicinal materials, a systematic and operable traceability system needs to be established. It can realize the whole process of quality and safety management of Chinese medicinal materials "from production to consumption" through recording and inquiring information and recalling defective products, which is an important direction for the future development of traditional Chinese medicine. But it is still at the exploration and trial stage. In this paper, a framework of Chinese medicinal materials' quality and safety traceability system was established on the basis of the domestic and international experience about the construction of food and agricultural products traceability systems. The relationship between traceability system of Chinese medicinal materials' quality and GAP, GMP, GSP was analyzed, and the possible problems and the corresponding solutions were discussed.

  13. Quality assurance manual for the development of digital systems

    International Nuclear Information System (INIS)

    Lee, Cheol Kwon; Kwon, Kee Choon; You, Young Eun; Kim, Kwan Hyun; Park, Jung Woo; Park, Chan Seok

    2001-12-01

    A digital safety system is being developed by three companies under the Korea Nuclear I and C System R and D Program. This Quality Assurance Manual (QAM) is written to ensure the safety and reliability of the system and to meet the regulatory requirements associated with quality assurance. This QAM describes eighteen elements of quality assurance criteria required for the development of the system, which are coincident with the criteria specified in Nuclear Energy Laws and Enforcement Regulations of Nuclear Energy Laws and 10CFR50 Appendix B. This QAM is submitted to the regulatory body with other documents related to the quality assurance activities performed during the system development. And its safety, validity and fulfillment are reviewed and audited in the review process of topical report of the digital safety system

  14. Increasing the supply of kidneys for transplantation by making living donors the preferred source of donor kidneys.

    Science.gov (United States)

    Testa, Giuliano; Siegler, Mark

    2014-12-01

    At the present time, increasing the use of living donors offers the best solution to the organ shortage problem. The clinical questions raised when the first living donor kidney transplant was performed, involving donor risk, informed consent, donor protection, and organ quality, have been largely answered. We strongly encourage a wider utilization of living donation and recommend that living donation, rather than deceased donation, become the first choice for kidney transplantation. We believe that it is ethically sound to have living kidney donation as the primary source for organs when the mortality and morbidity risks to the donor are known and kept extremely low, when the donor is properly informed and protected from coercion, and when accepted national and local guidelines for living donation are followed.

  15. Power quality load management for large spacecraft electrical power systems

    Science.gov (United States)

    Lollar, Louis F.

    1988-01-01

    In December, 1986, a Center Director's Discretionary Fund (CDDF) proposal was granted to study power system control techniques in large space electrical power systems. Presented are the accomplishments in the area of power system control by power quality load management. In addition, information concerning the distortion problems in a 20 kHz ac power system is presented.

  16. Sequence Coding and Search System Backfit Quality Assurance Program Plan

    International Nuclear Information System (INIS)

    Lovell, C.J.; Stepina, P.L.

    1985-03-01

    The Sequence Coding and Search System is a computer-based encoding system for events described in Licensee Event Reports. This data system contains LERs from 1981 to present. Backfit of the data system to include LERs prior to 1981 is required. This report documents the Quality Assurance Program Plan that EG and G Idaho, Inc. will follow while encoding 1980 LERs

  17. Fuel element radiometry system for quality control

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Gaur, Swati; Sridhar, Padmini; Mukhopadhyay, P.K.; Vaidya, P.R.; Das, Sanjoy; Sinha, A.K.; Bhatt, Sameer

    2010-01-01

    An indigenous and fully automatic PC based radiometry system has been designed and developed. The system required a vibration free scanning with various automated sequential movements to scan the fuel pin of size 5.8 mm (OD) x 1055 mm (L) along its full length. A mechanical system with these requirements and precision controls has been designed. The system consists of a tightly coupled and collimated radiation source-detector unit and data acquisition and control system. It supports PLC based control electronics to control and monitor the movement of fuel element, nuclear data acquisition and analysis system and feedback system to the mechanical scanner to physically accept or reject the fuel pin based on the decision derived by the software algorithms. (author)

  18. Quality of Financial Policies and Financial System Stress

    OpenAIRE

    Udaibir S Das; Plamen Yossifov; Richard Podpiera; Dmitriy L Rozhkov

    2005-01-01

    In this paper, we develop multi-country indices of financial system stress and quality of financial policies and use them in regression analysis of the determinants of financial stress. We find that countries with higher quality of financial policies are better able to contain the effects of macroeconomic pressures on the overall level of stress in the financial system. They are also in a better position to ensure sustainable development of the financial system.

  19. Quality system implementation in the Radiotoxicology Laboratory of IPEN, Brazil

    International Nuclear Information System (INIS)

    Gaburo, J.C.; Caldeira Filho, J.S.; Todo, A.S.; Sanches, M.; Campos, L.L.

    2002-01-01

    The perception of assured quality is getting more transparence in the research and development areas. The Radiotoxicology Laboratory, LRT, of IPEN, operating since 1978, has as main attribution the development and implantation of analytical techniques for the measurements of different radionuclides in biological samples. Thus, the LRT considers being of extreme importance to have a management of the quality system to guarantee the reliability of the results and to obtain Accreditation Certificate of the National Institute of Metrology, INMETRO. With this objective the LRT has participated of projects of quality assurance for analytical laboratories since 1997, promoted by International Atomic Energy Agency, IAEA. Currently the quality system of the LRT is in implementation phase, operating in compliance with the quality system of IPEN (consistent pair ISO 9001-9004:2000) and with NBR ISO/IEC 17025. The quality system implemented in the LRT is described in its Quality Manual, MQ-LRT and in complementary procedures that are in their first revision. The participation of the laboratory in intercomparison programs among national as international laboratories and the analysis of the results of internal as well as external audits has demonstrated that the LRT laboratory presents good performance and with suitable methodology and accurate and precise results. With the implementation of the quality system it was possible to verify the effectiveness and efficiency of the tests carried out in the Radiotoxicology Laboratory. The project ARCAL XXVI was concluded in November 2001 and the LRT earned the Certificate of Recognition by IAEA. (author)

  20. Predicting the Overall Spatial Quality of Automotive Audio Systems

    Science.gov (United States)

    Koya, Daisuke

    The spatial quality of automotive audio systems is often compromised due to their unideal listening environments. Automotive audio systems need to be developed quickly due to industry demands. A suitable perceptual model could evaluate the spatial quality of automotive audio systems with similar reliability to formal listening tests but take less time. Such a model is developed in this research project by adapting an existing model of spatial quality for automotive audio use. The requirements for the adaptation were investigated in a literature review. A perceptual model called QESTRAL was reviewed, which predicts the overall spatial quality of domestic multichannel audio systems. It was determined that automotive audio systems are likely to be impaired in terms of the spatial attributes that were not considered in developing the QESTRAL model, but metrics are available that might predict these attributes. To establish whether the QESTRAL model in its current form can accurately predict the overall spatial quality of automotive audio systems, MUSHRA listening tests using headphone auralisation with head tracking were conducted to collect results to be compared against predictions by the model. Based on guideline criteria, the model in its current form could not accurately predict the overall spatial quality of automotive audio systems. To improve prediction performance, the QESTRAL model was recalibrated and modified using existing metrics of the model, those that were proposed from the literature review, and newly developed metrics. The most important metrics for predicting the overall spatial quality of automotive audio systems included those that were interaural cross-correlation (IACC) based, relate to localisation of the frontal audio scene, and account for the perceived scene width in front of the listener. Modifying the model for automotive audio systems did not invalidate its use for domestic audio systems. The resulting model predicts the overall spatial

  1. Optimum power quality service in multi-bus microgrid systems

    DEFF Research Database (Denmark)

    Meng, Lexuan; Guerrero, Josep M.

    2017-01-01

    Power quality requirements for different consumers and electric equipment are distinguished. Conventionally a common power quality standard is applied to the whole power grid inducing debate between several sides, including consumers, generation sites and technical commissions. Customized power...... quality standard settings for different consumers become a widely accepted solution. The main challenge is on the proper regulation of power quality in different areas. This paper considers a multi-bus microgrid system where the power quality in each has flexible and individual standard. Distributed...... generators are utilized to provide power quality regulation functions. An optimization method based strategy is proposed and implemented with the power converter control system. A general mathematical model is established which can be used in the optimization problem for evaluating the objective function...

  2. Production system with process quality control: modelling and application

    Science.gov (United States)

    Tsou, Jia-Chi

    2010-07-01

    Over the past decade, there has been a great deal of research dedicated to the study of quality and the economics of production. In this article, we develop a dynamic model which is based on the hypothesis of a traditional economic production quantity model. Taguchi's cost of poor quality is used to evaluate the cost of poor quality in the dynamic production system. A practical case from the automotive industry, which uses the Six-sigma DMAIC methodology, is discussed to verify the proposed model. This study shows that there is an optimal value of quality investment to make the production system reach a reasonable quality level and minimise the production cost. Based on our model, the management can adjust its investment in quality improvement to generate considerable financial return.

  3. The ALICE data quality monitoring system

    International Nuclear Information System (INIS)

    Haller, B von; Telesca, A; Chapeland, S; Carena, F; Carena, W; Barroso, V Chibante; Costa, F; Denes, E; Divià, R; Fuchs, U; Simonetti, G; Soós, C; Vyvre, P Vande

    2011-01-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.

  4. The ALICE data quality monitoring system

    Science.gov (United States)

    von Haller, B.; Telesca, A.; Chapeland, S.; Carena, F.; Carena, W.; Chibante Barroso, V.; Costa, F.; Denes, E.; Divià, R.; Fuchs, U.; Simonetti, G.; Soós, C.; Vande Vyvre, P.; ALICE Collaboration

    2011-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). The online Data Quality Monitoring (DQM) is a key element of the Data Acquisition's software chain. It provide shifters with precise and complete information to quickly identify and overcome problems, and as a consequence to ensure acquisition of high quality data. DQM typically involves the online gathering, the analysis by user-defined algorithms and the visualization of monitored data. This paper describes the final design of ALICE'S DQM framework called AMORE (Automatic MOnitoRing Environment), as well as its latest and coming features like the integration with the offline analysis and reconstruction framework, a better use of multi-core processors by a parallelization effort, and its interface with the eLogBook. The concurrent collection and analysis of data in an online environment requires the framework to be highly efficient, robust and scalable. We will describe what has been implemented to achieve these goals and the procedures we follow to ensure appropriate robustness and performance. We finally review the wide range of usages people make of this framework, from the basic monitoring of a single sub-detector to the most complex ones within the High Level Trigger farm or using the Prompt Reconstruction and we describe the various ways of accessing the monitoring results. We conclude with our experience, before and after the LHC startup, when monitoring the data quality in a challenging environment.

  5. BLOOD DONORS CAMPAIGN

    CERN Document Server

    Medical Service

    2002-01-01

    Tuesday 19 March 2002 in restaurant nr 2, from 9.00 to 16.30 hrs A blood donors campaign, organized by the Centre de Transfusion sanguine of Geneva If you already have a card giving your blood group, please bring this with you.

  6. BLOOD DONORS CAMPAIGN

    CERN Multimedia

    2001-01-01

    A blood donors campaign, organized by the Centre de Transfusion Sanguine of Geneva will be held at CERN on Tuesday 13 March 2001 in restaurant nr 2, from 9.00 to 16.30 hrs If you already have a card giving your blood group, please bring this with you.

  7. BLOOD DONORS CAMPAIGN

    CERN Document Server

    2002-01-01

    Wednesday 13 November 2002 in restaurant nr 2, from 8.30 to 16.30 hrs will be held a blood donors campaign, organized by the Etablissement de Transfusion de Haute-Savoie If you already have a card giving your blood group, please bring this with you.

  8. BLOOD DONORS CAMPAIGN

    CERN Document Server

    2000-01-01

    A blood donors campaign, organized by the Établissement de Transfusion de Rhône-Alpes will be held at CERN on Tuesday 14 November 2000 in restaurant nr 2, from 8.30 to 16.30 hrs If you already have a card giving your blood group, please bring this with you.

  9. BLOOD DONORS CAMPAIGN

    CERN Document Server

    2001-01-01

    A blood donors campaign, organized by the Centre de Transfusion d'Annemasse will be held at CERN on Tuesday 14 November 2001 in restaurant nr 2, from 9.00 to 16.30 hrs If you already have a card giving your blood group, please bring this with you.

  10. Donor transplant programme

    International Nuclear Information System (INIS)

    Abu Bakar Sulaiman

    1999-01-01

    The transplantation of organs and tissues from one human to another human has become an essential and well established form of therapy for many types of organ and tissue failure. In Malaysia, kidney, cornea and bone marrow transplantation are well established. Recently, liver, bone and heart transplanation have been performed. Unfortunately, because of the lack of cadaveric organ donation, only a limited number of solid organ transplantation have been performed. The cadaveric organ donor rate in Malaysia is low at less than one per million population. The first tissue transplanted in Malaysia was the cornea which was performed in the early 1970s. At that time and even now the majority of corneas came from Sri Lanka. The first kidney transplant was performed in 1975 from a live related donor. The majority of the 629 kidney transplants done at Hospital Kuala Lumpur to date have been from live related donors. Only 35 were from cadaver donors. Similarly, the liver transplantation programme which started in 1995 are from live related donors. A more concerted effort has been made recently to increase the awareness of the public and the health professionals on organ and tissue donation. This national effort to promote organ and tissue donation seems to have gathered momentum in 1997 with the first heart transplant successfully performed at the National Heart Institute. The rate of cadaveric donors has also increased from a previous average of I to 2 per year to 6 per year in the last one year. These developments are most encouraging and may signal the coming of age of our transplantati on programme. The Ministry of Health in conjunction with various institutions, organizations and professional groups, have taken a number of proactive measures to facilitate the development of the cadaveric organ donation programme. Efforts to increase public awareness and to overcome the negative cultural attitude towards organ donation have been intensified. Equally important are efforts

  11. INDUSTRIAL ENTERPRISE MANAGEMENT SYSTEM QUALITY ASSESMENT

    Directory of Open Access Journals (Sweden)

    S. V. Pankov

    2012-01-01

    Full Text Available Management systems of small-scale enterprises in Moscow region are of centralized linear type. Misunderstanding of the need for qualitymanagement operational processes is observed in such business structures. Using correct management systems results in reduction of business costs and increase of business economic efficiency and entrepreneurship social role.

  12. Quality of Tourism and Hospitality Management Systems in Russia

    Directory of Open Access Journals (Sweden)

    Irina N. Markaryan

    2013-01-01

    Full Text Available This article describes the features of quality standards (ISO, their application in Russia, analyzes Quality Awards, awarded to Russian producers, such as the Award of the Government of the Russian Federation in the field of Quality, National Tourism Award named after Yu. Senkevich, Travel Award «Golden Meridian», Moscow “Guiding Star” Award. The objectives of management system for Sochi resorts and hotels were determined

  13. Monitoring and analyzing features of electrical power quality system performance

    OpenAIRE

    Genci Sharko; Nike Shanku

    2010-01-01

    Power quality is a set of boundaries that allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly with that electric power. Without the proper quality of the power, an electrical device may malfunction, fail prematurely or not operate at all. There are many reasons why the electric power can be of poor quality and many m...

  14. Information system quality in work-life balance

    Directory of Open Access Journals (Sweden)

    Sharmini Gopinathan

    2016-06-01

    Full Text Available This paper aims to look for the role information systems quality may play in work-life balance among Malaysian ICT employees. The results of this study will be useful in the development of new tools and technologies that are focused on ISQ dimensions primarily information system quality which can be helpful to devise suggestions to the ICT sector on matters pertaining to sustainable development/policy formulation with reference to achieving a good work-life balance. A total of 79 respondents’ views were analyzed using Partial Least Square (PLS to obtain the final results. The results showed that information quality and system quality has strong effect on work-life balance as compared to service quality which showed no relation to work-life balance.

  15. Water quality management in shrimp aquaculture ponds using remote water quality logging system

    Digital Repository Service at National Institute of Oceanography (India)

    Sreepada, R.A.; Kulkarni, S.; Suryavanshi, U.; Ingole, B.S.; Drensgstig, A.; Braaten, B.

    Currently an institutional co-operation project funded by NORAD is evaluating different environmental management strategies for sustainable aquaculture in India. A brief description of a remote water quality logging system installed in shrimp ponds...

  16. Effects of Quality Improvement System for Child Care Centers

    Science.gov (United States)

    Ma, Xin; Shen, Jianping; Kavanaugh, Amy; Lu, Xuejin; Brandi, Karen; Goodman, Jeff; Till, Lance; Watson, Grace

    2011-01-01

    Using multiple years of data collected from about 100 child care centers in Palm Beach County, Florida, the authors studied whether the Quality Improvement System (QIS) made a significant impact on quality of child care centers. Based on a pre- and postresearch design spanning a period of 13 months, QIS appeared to be effective in improving…

  17. Approach the National Quality Audit System for Radiotherapy in Latvia

    OpenAIRE

    Dehtjars, J; Popovs, S; Plaude, S

    2008-01-01

    It is very important to make National Quality Audit to ensure accurate conformal RT delivery. It is necessary to develop an Audit system to inspect all Conformal RT and IMRT delivery chain including the Quality checks of linear accelerator, Multileaf Collimator (MLC), Computer Tomography (CT) scanner or simulator, target and tissue delineation, plan evaluation, and delivery.

  18. Accreditation and Quality Assurance in the Egyptian Higher Education System

    Science.gov (United States)

    Schomaker, Rahel

    2015-01-01

    Purpose: This study aims to analyze the quality of the Egyptian accreditation system. With a view on the high competition in the domestic labor market as well as with regards to the international competitiveness of Egyptian graduates and the potential role of Egyptian universities in the international market for higher education, a high quality of…

  19. Quality Rating and Improvement Systems and Children's Cognitive Development

    Science.gov (United States)

    Jeon, Lieny; Buettner, Cynthia K.

    2015-01-01

    Background: Providing enriched learning environments is important to stimulating children's development in early childhood. Early child-care policymakers in many states in the US have adopted Quality Rating and Improvement Systems (QRIS) as a way to verify quality of child care and to support children's school readiness. Objective: The purpose of…

  20. Quality Evaluation in Flexible Manufacturing Systems: A Markovian Approach

    Directory of Open Access Journals (Sweden)

    Jingshan Li

    2007-01-01

    to illustrate the applicability of the method. The results of this study suggest a possible approach to investigate the impact of flexibility on product quality and, finally, with extensions and enrichment of the model, may lead to provide production engineers and managers a better understanding of the quality implications and to summarize some general guidelines of operation management in flexible manufacturing systems.

  1. A novel colonoscopy reporting system enabling quality assurance

    NARCIS (Netherlands)

    van Doorn, Sascha C.; van Vliet, Joost; Fockens, Paul; Dekker, Evelien

    2014-01-01

    The quality of colonoscopy can only be measured if colonoscopy reports include all key quality indicators. In daily practice, reporting is often incomplete and not standardized. This study describes a novel, structured colonoscopy reporting system, which aims to generate standardized and complete

  2. Frequency and risk factors for donor reactions in an anonymous blood donor survey.

    Science.gov (United States)

    Goldman, Mindy; Osmond, Lori; Yi, Qi-Long; Cameron-Choi, Keltie; O'Brien, Sheila F

    2013-09-01

    Adverse donor reactions can result in injury and decrease the likelihood of donor return. Reaction reports captured in the blood center's database provide an incomplete picture of reaction rates and risk factors. We performed an anonymous survey, mailed to 40,000 donors in 2008, including questions about symptoms, height, weight, sex, and donation status. Reaction rates were compared to those recorded in our database. Possible risk factors were assessed for various reactions. The response rate was 45.5%. A total of 32% of first-time and 14% of repeat donors reported having any adverse symptom, most frequently bruising (84.9 per 1000 donors) or feeling faint or weak (66.2 per 1000). Faint reactions were two to eight times higher than reported in our database, although direct comparison was difficult. Younger age, female sex, and first-time donation status were risk factors for systemic and arm symptoms. In females, low estimated blood volume (EBV) was a risk factor for systemic symptoms. Only 51% of donors who consulted an outside physician also called Canadian Blood Services. A total of 10% of first-time donors with reactions found adverse effects information inadequate. This study allowed us to collect more information about adverse reactions, including minor symptoms and delayed reactions. Based on our findings of the risk factors and frequency of adverse reactions, we are implementing more stringent EBV criteria for younger donors and providing more detailed information to donors about possible adverse effects and their management. © 2012 American Association of Blood Banks.

  3. Healthcare delivery systems: designing quality into health information systems.

    Science.gov (United States)

    Joyce, Phil; Green, Rosamund; Winch, Graham

    2007-01-01

    To ensure that quality is 'engineered in' a holistic, integrated and quality approach is required, and Total Quality Management (TQM) principles are the obvious foundations for this. This paper describes a novel approach to viewing the operations of a healthcare provider where electronic means could be used to distribute information (including electronic fund settlements), building around the Full Service Provider core. Specifically, an approach called the "triple pair flow" model is used to provide a view of healthcare delivery that is integrated, yet detailed, and that combines the strategic enterprise view with a business process view.

  4. Synthesis and electrochemical characterization of new optoelectronic materials based on conjugated donor-acceptor system containing oligo-tri(heteroaryl)-1,3,5-triazines

    International Nuclear Information System (INIS)

    Idzik, Krzysztof R.; Rapta, Peter; Cywinski, Piotr J.; Beckert, Rainer; Dunsch, Lothar

    2010-01-01

    A series of novel oligoarylenes based on donor-acceptor system, containing triazine moiety as an electron-transporting central core, have been prepared by electrochemical polymerization. The redox behaviour of poly(2,4,6-tri[p-(2-(3,4-ethylenedioxythienyl))-phenyl]-1,3,5-triazine) was studied by cyclic voltammetry and triple in situ ESR/UV-vis-NIR spectroelectrochemistry to get more details on the type of charge carriers within the film. To obtain desired oligoarylenes, triazine-core monomers possessing various electrochromic side groups have been synthesized by the Stille cross-coupling methodology. The structures have been confirmed by 1 H NMR, 13 C NMR, and elemental analysis. Monomers show good chemical stability in common organic solvents such as chloroform, dichloromethane or toluene and also exhibit excellent thermal stability over wide range of temperatures. Furthermore, their photophysical properties have been established with the use of fluorescence spectroscopy. Electrochemical results accompanied with fluorescence spectroscopy suggest that these derivatives of triazine can be successfully used in the fabrication of organic light-emitting diodes (OLEDs).

  5. Implementing a Quality Management System in the Medical Microbiology Laboratory.

    Science.gov (United States)

    Carey, Roberta B; Bhattacharyya, Sanjib; Kehl, Sue C; Matukas, Larissa M; Pentella, Michael A; Salfinger, Max; Schuetz, Audrey N

    2018-07-01

    This document outlines a comprehensive practical approach to a laboratory quality management system (QMS) by describing how to operationalize the management and technical requirements described in the ISO 15189 international standard. It provides a crosswalk of the ISO requirements for quality and competence for medical laboratories to the 12 quality system essentials delineated by the Clinical and Laboratory Standards Institute. The quality principles are organized under three main categories: quality infrastructure, laboratory operations, and quality assurance and continual improvement. The roles and responsibilities to establish and sustain a QMS are outlined for microbiology laboratory staff, laboratory management personnel, and the institution's leadership. Examples and forms are included to assist in the real-world implementation of this system and to allow the adaptation of the system for each laboratory's unique environment. Errors and nonconforming events are acknowledged and embraced as an opportunity to improve the quality of the laboratory, a culture shift from blaming individuals. An effective QMS encourages "systems thinking" by providing a process to think globally of the effects of any type of change. Ultimately, a successful QMS is achieved when its principles are adopted as part of daily practice throughout the total testing process continuum. Copyright © 2018 American Society for Microbiology.

  6. The healthy donor effect impacts self-reported physical and mental health - results from the Danish Blood Donor Study (DBDS)

    DEFF Research Database (Denmark)

    Rigas, A S; Skytthe, A; Erikstrup, C

    2017-01-01

    AIMS: This study aimed at quantifying the healthy donor effect by comparing self-perceived mental and physical health between blood donors and non-donors. BACKGROUND: In theory, the selection process known as the healthy donor effect should result in better self-perceived, health-related quality...... of life in donors than in non-donors. METHODS: The Short Form-12 data from the Danish Twin Registry (DTR) was compared with the data from the Danish Blood Donor Study (DBDS). Data on age, sex and smoking status were included in the analyses. The multivariable linear regression analysis was stratified......-perceived mental health was associated with a blood donor. With the increase in age, better self-perceived physical health was associated with blood donation....

  7. EFFECT OF QUALITY CONTROL SYSTEM ON AUDIT QUALITY WITH PROFESSIONAL COMMITMENTS AS A MODERATION VARIABLE

    Directory of Open Access Journals (Sweden)

    Ramadhani R.

    2017-12-01

    Full Text Available This study aims to test the effect of every element of Quality Control System (QCS that is leadership responsibilities for quality on audit, relevant ethical requirements, acceptance and continuance of client relationships and certain engagements, assignment of engagement team, engagement performance, monitoring, and documentation on audit quality as well as to test whether the professional commitment moderate effect of every element of QCS on audit quality. The population was the staff auditors working in public accounting firms domiciled in Jakarta City, especially Central Jakarta area with the drawing of 84 respondents. The statistical method used was SEM PLS with the help of SmartPLS application. The results of this study indicate that from seven elements of QCS, only relevant ethical requirements that affect on audit quality. Furthermore, the study also found that professional commitment cannot moderate the relationship between the seven elements of QCS on audit quality.

  8. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  9. Methods of multicriterion estimations in system total quality management

    Directory of Open Access Journals (Sweden)

    Nikolay V. Diligenskiy

    2011-05-01

    Full Text Available In this article the method of multicriterion comparative estimation of efficiency (Data Envelopment Analysis and possibility of its application in system of total quality management is considered.

  10. An evaluation of professional quality measurement systems for the ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... An evaluation of professional quality measurement systems for the automotive industry ... The ultimate goal of this study is to get comparable quantitative information about ...

  11. Air Quality Monitoring and Information System for Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.

    1996-06-01

    The publication relates to the main objectives and design of a modern monitoring and information system developed in Norway. The system is to be installed in Egypt. Themes being discussed cover technical features of the system, meteorological data, environmental indicators, data transfer and quality assurance, the data bases, data presentation - graphics and GIS, and environmental information to the public. 11 figs., 1 tab.

  12. Systems Science in Support of Total Quality Management,

    Science.gov (United States)

    Quality Management (TQM). This paper bridges the gap between these two subjects to illustrate specific means by which systems science can begin to augment TQM. This construction is based upon the consideration of two topics. First, a brief introduction to systems science is provided. Second, systems science is applied through the concept of the Conant-Ashby

  13. Complement mediated renal inflammation induced by donor brain death : role of renal C5a-C5aR interaction

    NARCIS (Netherlands)

    van Werkhoven, M. B.; Damman, J.; van Dijk, M. C. R. F.; Daha, M. R.; de Jong, I. J.; Leliveld, A.; Krikke, C.; Leuvenink, H. G.; van Goor, H.; van Son, W. J.; Olinga, P.; Hillebrands, J. -L.; Seelen, M. A. J.

    Kidneys retrieved from brain-dead donors have impaired allograft function after transplantation compared to kidneys from living donors. Donor brain death (BD) triggers inflammatory responses, including both systemic and local complement activation. The mechanism by which systemic activated

  14. Quality Management System Improves Effectiveness and Quality of Activities of Radiation Protection Regulatory Body in Lithuania

    International Nuclear Information System (INIS)

    Mastauskas, A.

    2016-01-01

    Processes of creation of quality management system (QMS) in regulatory body in radiation protection field – Radiation Protection Centre (RPC) and the benefit of this system to ensure the quality of the performance of functions are described. RPC QMS compliant with ISO 9001:2008 standard and in line with the requirements of the IAEA GSR- 3 document. It allowed achieving a new quality of works carried out by RPC. Because creation and introduction of the QMS is a continuous process, the QMS of RPC is continually renewed and new procedures are developed.

  15. A Cu-Zn nanoparticle promoter for selective carbon dioxide reduction and its application in visible-light-active Z-scheme systems using water as an electron donor.

    Science.gov (United States)

    Yin, Ge; Sako, Hiroshi; Gubbala, Ramesh V; Ueda, Shigenori; Yamaguchi, Akira; Abe, Hideki; Miyauchi, Masahiro

    2018-04-17

    Selective carbon dioxide photoreduction to produce formic acid was achieved under visible light irradiation using water molecules as electron donors, similar to natural plants, based on the construction of a Z-scheme light harvesting system modified with a Cu-Zn alloy nanoparticle co-catalyst. The faradaic efficiency of our Z-scheme system for HCOOH generation was over 50% under visible light irradiation.

  16. Overview of the EPA quality system for environmental programs

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.L. [Environmental Protection Agency, Research Triangle Park, NC (United States)

    1993-12-31

    Formalized quality assurance program requirements for the U.S. Environmental Protection Agency (EPA) have been established for more than a decade. During this period, the environmental issues and concerns addressed by the EPA have changed. Many issues, such as ozone depletion and global climate warming, have become international concerns among the world environmental community. Other issues, such as hazardous waste cleanup and clean air, remain a focus of national environmental concerns. As the environmental issues of the 1980`s evolved, the traditional quality assurance (QA) program was transformed through the use of quality management principles into a Quality System to help managers meet the needs of the 1990`s and beyond.

  17. Systems and processes that ensure high quality care.

    Science.gov (United States)

    Bassett, Sally; Westmore, Kathryn

    2012-10-01

    This is the second in a series of articles examining the components of good corporate governance. It considers how the structures and processes for quality governance can affect an organisation's ability to be assured about the quality of care. Complex information systems and procedures can lead to poor quality care, but sound structures and processes alone are insufficient to ensure good governance, and behavioural factors play a significant part in making sure that staff are enabled to provide good quality care. The next article in this series looks at how the information reporting of an organisation can affect its governance.

  18. Research on airborne comprehensive survey system of atmosphere quality

    International Nuclear Information System (INIS)

    Yu Zhentao; Yu Yanbin

    1998-01-01

    The global atmosphere pollution is becoming more and more serious, affecting the human existence and development. Besides, the high spectrum resolution remote sensing technique, which has been applied to observe topographic features, identify military objectives and distinguish lithology and vegetation, has the relation to atmosphere quality and is influenced by atmosphere pollution (including radon pollution) and dust content in the atmosphere, it is imperative to monitor atmosphere quality. Based upon the selection of some main parameters evaluating atmospheric quality and necessary equipment, the author introduces the design of multiple airborne comprehensive survey system of atmosphere quality and how to deal with problems that crop up during the hardware designing and software programming

  19. Overview of the EPA quality system for environmental programs

    International Nuclear Information System (INIS)

    Johnson, G.L.

    1993-01-01

    Formalized quality assurance program requirements for the U.S. Environmental Protection Agency (EPA) have been established for more than a decade. During this period, the environmental issues and concerns addressed by the EPA have changed. Many issues, such as ozone depletion and global climate warming, have become international concerns among the world environmental community. Other issues, such as hazardous waste cleanup and clean air, remain a focus of national environmental concerns. As the environmental issues of the 1980's evolved, the traditional quality assurance (QA) program was transformed through the use of quality management principles into a Quality System to help managers meet the needs of the 1990's and beyond

  20. Water Quality Impacts of Cover Crop/Manure Management Systems

    OpenAIRE

    Kern, James Donald

    1997-01-01

    Crop production, soil system, water quality, and economic impacts of four corn silage production systems were compared through a field study including 16 plots (4 replications of each treatment). Systems included a rye cover crop and application of liquid dairy manure in the spring and fall. The four management systems were: 1) traditional, 2) double- crop, 3) roll-down, and 4) undercut. In the fourth system, manure was applied below the soil surface during the ...

  1. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  2. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  3. The study of surgical image quality evaluation system by subjective quality factor method

    Science.gov (United States)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  4. Ljubljana quality selection (LQS) - innovative case of restaurant assessment system

    OpenAIRE

    Maja Uran Maravić; Daniela Gračan; Zrinka Zadel

    2014-01-01

    The purpose – The purpose of this paper is to briefly present the most well-known restaurant assessment systems where restaurant are assessed by experts. The aim is to highlight the strengths and weaknesses of each system. Design –The special focus is to give answers on questions: how are the restaurants assessed by experts, which are the elements and standards of assessment and whether they are consistent with the quality dimensions as advocated in the theory of service quality. Methodology ...

  5. Information system quality in work-life balance

    OpenAIRE

    Sharmini Gopinathan; Murali Raman

    2016-01-01

    This paper aims to look for the role information systems quality may play in work-life balance among Malaysian ICT employees. The results of this study will be useful in the development of new tools and technologies that are focused on ISQ dimensions primarily information system quality which can be helpful to devise suggestions to the ICT sector on matters pertaining to sustainable development/policy formulation with reference to achieving a good work-life balance. A total of 79 respondents’...

  6. A System That Works: Highlights of Effective Intervention Strategies in a Quality Improvement System

    Science.gov (United States)

    Sinisterra, Diana; Baker, Stephen

    2010-01-01

    This paper describes one approach to quality improvement efforts: the Quality Improvement System (QIS) implemented by Prime Time Palm Beach County (Prime Time) in Palm Beach County, Florida. Prime Time's QIS is recognized as one promising systemic effort to improve quality in the afterschool field (Yohalem, Granger, & Pittman, 2009). As a…

  7. Quality of clinical data aware telemedicine systems

    NARCIS (Netherlands)

    Larburu Rubio, Nekane

    2016-01-01

    Healthcare services have been evolving continuously owing to new demands caused by demographic and lifestyle changes. The advancements in information and communication technology (ICT) have propelled the development of new healthcare systems that can fulfil these demands. One of the key developments

  8. Supplier quality assurance systems: a study in the nuclear industry

    International Nuclear Information System (INIS)

    Singer, A.J.; Churchill, G.F.; Dale, B.G.

    1988-01-01

    The results are reported of a study which investigated the impact of quality assurance on 13 suppliers to the nuclear industry. The purpose of the study was to determine the benefits and problems of applying quality assurance in the supply of high risk plant items and material for nuclear installations. The paper discusses the problems facing the industry including: multiple audits and inspections, the irritation with having to contend with two quality system standards (namely BS 5750 and BS 5882) and the cost effectiveness of the more stringent quality system and quality control surveillance requirements imposed by the nuclear industry. It is also pointed out that companies supplying non-nuclear industrial customers were dissatisfied with the qualifications, experience and professional competence of some auditors and many inspectors. (author)

  9. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  10. An Architectural Style for Optimizing System Qualities in Adaptive Embedded Systems using Multi-Objective Optimization

    NARCIS (Netherlands)

    de Roo, Arjan; Sözer, Hasan; Aksit, Mehmet

    Customers of today's complex embedded systems demand the optimization of multiple system qualities under varying operational conditions. To be able to influence the system qualities, the system must have parameters that can be adapted. Constraints may be defined on the value of these parameters.

  11. Modern control system of quality of services of public catering

    Directory of Open Access Journals (Sweden)

    Lavrova Larisa Jur'evna

    2015-12-01

    Full Text Available The modern control system of quality of services of public catering as the instrument of management of safety is effective and legitimate. In article changes in requirements of normative documents are considered. Interdisciplinary mechanisms of implementation of requirements of normative documents are described. Uniform approaches between marketing and quality management regarding monitoring of satisfaction of consumers are determined. Results of researches of the organization of collection of information about degree of satisfaction of consumers are described. Knowledge, necessary for the staff of catering establishments, and skills regarding development, introduction and maintenance of quality management system in activity of the enterprises of food are established.

  12. [Outcome of living kidney donors for transplantation].

    Science.gov (United States)

    Lanot, Antoine; Bouvier, Nicolas; Chatelet, Valérie; Lecouf, Angélique; Tillou, Xavier; Hurault de Ligny, Bruno

    2017-11-01

    Nowadays, several treatments exist to treat terminal chronic renal failure. Best results for the recipients are obtained with kidney transplantation concerning mortality and quality of life. Transplantation is also the cheaper option for society. Living kidney donation raises the issue of the becoming of the donor, an absolutely healthy subject who gets to a surgical procedure. The becoming of living kidney donors has been compared with the one of controls subjects in several studies. The evaluations focused on the complications of nephrectomy in the short and long-term: kidney failure, hypertension, proteinuria, possibility of pregnancy, quality of life, and mortality. The first results did not show any risk linked to kidney donation, compared to general population. However, since 2013, kidney donors were found at higher risk for kidney failure and even for mortality, compared with controls selected like donor candidates. The risk of kidney donation is nevertheless acceptable and minimal, on the condition of rigorous selection of candidates and regular follow-up. Copyright © 2017 Société francophone de néphrologie, dialyse et transplantation. Published by Elsevier Masson SAS. All rights reserved.

  13. Method of estimation of scanning system quality

    Science.gov (United States)

    Larkin, Eugene; Kotov, Vladislav; Kotova, Natalya; Privalov, Alexander

    2018-04-01

    Estimation of scanner parameters is an important part in developing electronic document management system. This paper suggests considering the scanner as a system that contains two main channels: a photoelectric conversion channel and a channel for measuring spatial coordinates of objects. Although both of channels consist of the same elements, the testing of their parameters should be executed separately. The special structure of the two-dimensional reference signal is offered for this purpose. In this structure, the fields for testing various parameters of the scanner are sp atially separated. Characteristics of the scanner are associated with the loss of information when a document is digitized. The methods to test grayscale transmitting ability, resolution and aberrations level are offered.

  14. STUDY OF BUSINESS INTELLIGENCE SYSTEM QUALITY

    OpenAIRE

    DENIC Nebojsa; VUJOVIC Vuk; PERENIC Goran; SPASIC Boban

    2016-01-01

    IT has made remarkable progress over the last years. Business intelligence systems have been developing as an important part of IT. Enterprises often fail to realize importance and necessity of implementation of business intelligence solutions. This paper will deal with the approach for assessment of business intelligence in enterprises, based on maturity models. The significance of this paper is in the development of new conceptual research models which do not apply the usual thesis on ma...

  15. Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario

    Directory of Open Access Journals (Sweden)

    Tondon Rashmi

    2009-01-01

    Full Text Available Background: Despite the wide range of methods available for measurement of hemoglobin, no single technique has emerged as the most appropriate and ideal for a blood donation setup. Materials and Methods: A prospective study utilizing 1014 blood samples was carried out in a blood donation setting for quality evaluation of four methods of hemoglobin estimation along with cost analysis: Hematology cell analyzer (reference, HCS, CuSO4 method and HemoCue. Results: Mean value of HemoCue (mean ± SD = 14.7 ± 1.49 g/dl was higher by 0.24 compared to reference (mean ± SD = 13.8 ± 1.52 g/dl but not statistically significant ( P > 0.05. HemoCue proved to be the best technique (sensitivity 99.4% and specificity 84.4% whereas HCS was most subjective with 25.2% incorrect estimations. CuSO4 proved to be good with 7.9% false results. Comparative cost analysis of each method was calculated to be 35 INR/test for HemoCue, 0.76 INR /test for HCS and 0.06-0.08 INR /test for CuSO4. Conclusion: CuSO4 method gives accurate results, if strict quality control is applied. HemoCue is too expensive to be used as a primary screening method in an economically restricted country like India.

  16. Individual, contextual and network characteristics of blood donors and non-donors: a systematic review of recent literature

    Science.gov (United States)

    Piersma, Tjeerd W.; Bekkers, René; Klinkenberg, Elisabeth F.; de Kort, Wim L.A.M.; Merz, Eva-Maria

    2017-01-01

    Background The ageing population and recent migration flows may negatively affect the blood supply in the long term, increasing the importance of targeted recruitment and retention strategies to address donors. This review sought to identify individual, network and contextual characteristics related to blood donor status and behaviour, to systematically discuss differences between study results, and to identify possible factors to target in recruitment and retention efforts. Methods The systematic review was conducted in accordance with a predefined PROSPERO protocol (CRD42016039591). After quality assessments by multiple independent raters, a final set of 66 peer-reviewed papers, published between October 2009 and January 2017, were included for review. Results Individual and contextual characteristics of blood donor status and behaviour were categorised into five main lines of research: donor demographics, motivations and barriers, adverse reactions and deferral, contextual factors, and blood centre factors. Results on donor demographics, motivations and barriers, and contextual factors were inconclusive, differing between studies, countries, and sample characteristics. Adverse reactions and deferral were negatively related to blood donor behaviour. Blood centre factors play an important role in donor management, e.g., providing information, reminders, and (non-)monetary rewards. No studies were found on network characteristics of (non-)donors. Discussion Although individual and contextual characteristics strongly relate to blood donor status and behaviour, mechanisms underlying these relations have not been studied sufficiently. We want to stress the importance of longitudinal studies in donor behaviour, exploring the role of life events and network characteristics within blood donor careers. Increased understanding of donor behaviour will assist policy makers of blood collection agencies, with the ultimate goal of safeguarding a sufficient and matching blood

  17. Individual, contextual and network characteristics of blood donors and non-donors: a systematic review of recent literature.

    Science.gov (United States)

    Piersma, Tjeerd W; Bekkers, René; Klinkenberg, Elisabeth F; De Kort, Wim L A M; Merz, Eva-Maria

    2017-09-01

    The ageing population and recent migration flows may negatively affect the blood supply in the long term, increasing the importance of targeted recruitment and retention strategies to address donors. This review sought to identify individual, network and contextual characteristics related to blood donor status and behaviour, to systematically discuss differences between study results, and to identify possible factors to target in recruitment and retention efforts. The systematic review was conducted in accordance with a predefined PROSPERO protocol (CRD42016039591). After quality assessments by multiple independent raters, a final set of 66 peer-reviewed papers, published between October 2009 and January 2017, were included for review. Individual and contextual characteristics of blood donor status and behaviour were categorised into five main lines of research: donor demographics, motivations and barriers, adverse reactions and deferral, contextual factors, and blood centre factors. Results on donor demographics, motivations and barriers, and contextual factors were inconclusive, differing between studies, countries, and sample characteristics. Adverse reactions and deferral were negatively related to blood donor behaviour. Blood centre factors play an important role in donor management, e.g., providing information, reminders, and (non-)monetary rewards. No studies were found on network characteristics of (non-)donors. Although individual and contextual characteristics strongly relate to blood donor status and behaviour, mechanisms underlying these relations have not been studied sufficiently. We want to stress the importance of longitudinal studies in donor behaviour, exploring the role of life events and network characteristics within blood donor careers. Increased understanding of donor behaviour will assist policy makers of blood collection agencies, with the ultimate goal of safeguarding a sufficient and matching blood supply.

  18. The Quality of Work in the Belgian Service Voucher System.

    Science.gov (United States)

    Mousaid, Sarah; Huegaerts, Kelly; Bosmans, Kim; Julià, Mireia; Benach, Joan; Vanroelen, Christophe

    2017-01-01

    Several European countries implemented initiatives to boost the growth of the domestic cleaning sector. Few studies investigated the quality of work in these initiatives, although effects on workers' health and on social health inequalities can be expected. This study contributes to the scant research on this subject, by investigating the quality of work in the Belgian service voucher system - a subsidized system for domestic work. The applied research methodology includes a qualitative content analysis of parliamentary debates, legislation and previous research about the service voucher system and of 40 in-depth interviews with service voucher workers. The study shows that the legal framework that regulates the system must be further enhanced in order to improve the quality of work in the service voucher system. In addition, the actors involved must be better controlled, and sanctioned in case of non-compliance with legislation. © The Author(s) 2016.

  19. Environmental Restoration Program quality system requirements for the Hanford Site

    International Nuclear Information System (INIS)

    Cote, R.F.

    1993-11-01

    This document defines the quality system requirements for the US Department of Energy, Richland Operations Office, Environmental Restoration Program at the Hanford Site. The Quality System Requirements (OSR) for the Hanford Site integrates quality assurance requirements from the US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), and applicable industry standards into a single source document for the development of quality systems applicable to the Environmental Restoration Program activities. This document, based on fifteen criteria and divided intro three parts, provides user organizations with the flexibility to incorporate only those criteria and parts applicable to their specific scopes of work. The requirements of this document shall be applied to activities that affect quality based on a graded approach that takes into consideration the risk inherent in, as well as the importance of, specific items, services, and activities in terms of meeting ER Program objectives and customer expectations. The individual quality systems developed in accordance with this document are intended to provide an integrated management control system that assures the conduct of ER Program activities in a manner that protects human health and the environment

  20. Clinical audit and quality systems - practical implementation in Finland

    International Nuclear Information System (INIS)

    Jaervinen, H.

    2003-01-01

    Clinical audit is a new concept of significant importance for the quality of radiological practices, introduced by the EC Medical Exposure Directive (MED, 97/43/EURATOM). By definition, clinical audit means 'a systematic examination or review of medical radiological procedures which seeks to improve the quality and the outcome of patient care, through structured review whereby radiological practices, procedures, and results are examined against agreed standards for good medical radiological procedures, with modifications of the practices where indicated and the application of new standards if necessary'. In its most profound meaning, being introduced in the medical exposure directive, clinical audit can be seen as a review of the success in implementing the justification and optimization principles, and therefore, it is to a large extent an issue of radiation safety for the patient. According to the directive, clinical audits shall be 'carried out in accordance with national procedures'. For the last few years, parallel to the development of the MED in Europe, there has been a worldwide tendency to implement appropriate quality systems (QS) in the health care organizations, in accordance with the international quality standards (ISO 9000 series etc). Such quality systems have been applied for a long time and very widely by the industry. It is a strong belief that the development of quality systems for health care would result in equal benefits as trusted in industry, in terms of efficiency and safety of health care services. For radiological practices, the quality systems are expected to become a framework for improving the optimization of practices and for maintaining good radiation safety, as well as providing a mechanism to prevent mistakes and accidents. In some countries, like the UK and The Netherlands, there are legal requirements to establish and maintain quality systems at certain type of radiological units. In some countries and some radiological units

  1. Quality plan and configuration management in complex systems

    International Nuclear Information System (INIS)

    Gonzalez Junto, J.; Merchan Teyssiere

    1993-01-01

    Since the Second World War, the philosophy behind the quality systems of industries and service companies has evolved to embrace the whole life cycle of the product, system or service. In this evolution process, quality has become a strategic factor in the survival of entreprises. The first steps in trying to establish quality systems were taken for the armed forces, followed by space, aeronautical and nuclear projects, whose products were more and more complex and sophisticated. These systems were established by means of quality plans or programmes, and their basic objective was to guarantee a high safety level for the user and/or the general population. In later years, the main concern was to reach a determined quality level not only in one phase of the product life, but in the complete life cycle of the final product. Today a new goal is established and pursued: better quality of the product, service or system life cycle at a lower cost. Methods of improving the quality of systems and processes are the subject of numerous initiatives and studies, to better availability and maintainability of complex equipment or installations, with an extended useful life and greater requirements. Experience in the performance of complex projects shows that a higher quality may be obtained through designing a comprehensive quality plan which pays special attention to information management and modifications of the original design. Obtaining a high reliability level for an installation (equipment, systems, etc), increasing its availability and rationalizing its maintenance may be little less than fanciful without a deep knowledge of the installation, of its activities and its current status in day-to-day operation, which shows the importance of truthful information available to operators and corresponding exactly to their needs. In this frame of mind, a quality plan comprising a configuration management system of information and documents constitutes the basic support tool for

  2. An approach to software quality assurance for robotic inspection systems

    International Nuclear Information System (INIS)

    Kiebel, G.R.

    1993-10-01

    Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site

  3. Correlation Between Information Technology And Management Information Systems Quality

    Directory of Open Access Journals (Sweden)

    Annisa Fitri Anggraeni

    2015-08-01

    Full Text Available The aim of this research is to find out the correlation between Information Technology and Management Information System Quality. This research applies literature review from various theories and previously conducted research where controversies between Information Technology and Management Information Systems. The result of this research shows that Information Technology is a part of Management Information System and supports the performance of Management Information Systems.

  4. Impact of gibberelic acid and tebuconazole on formation of the leaf system and functioning of donor – acceptor plant system of solanaceae vegetable crops

    Directory of Open Access Journals (Sweden)

    V. H. Kuryata

    2017-04-01

    Full Text Available We studied the comparable effect of gibberelic acid and tebuconazole on morphogenesis, mesostructure formation and redistribution of flows in sweet peppers and tomatoes. It has been found that the use of gibberelic acid and tebuconazole retardant during budding leads to increased plant productivity due to optimization of the structure and operation of the plants’ leaf apparatus. It was established that both gibberelic and antigibberelic tebuconazole drug stimulated the formation and functioning of the photosynthetic apparatus of peppers and tomatoes, but the mechanisms of this regulation were different. Increased photosynthetic activity of plants under the influence of gibberellin was determined primarily by the formation of more leaves and total leaf surface. When using tebuconazole retardant there was a significant restructuring of the organization of leaf mezostructure: the leaves were thickened by chlorenchyma proliferation, there was an increase in the volume of columnar parenchyma cells and linear dimensions of spongy parenchyma leaf cells. The surface density of leaves significantly increased, the chlorophyll content and nitrogen content (especially protein also increased, compared with control variants and variants using gibberelin. Such a profound restructuring of the photosynthetic apparatus in plants under the actions of tebuconazole led to a significant increase in donor leaves function of peppers and tomatoes, which is an indicator of the growth of net productivity of photosynthesis – the highest among all the variants of the experiment. The results also show that increasing the chlorophyll phytocenotic index was more significant than the increase of leaf index: the tomatoes under the action of tebuconazole had a lower leaf index than in control options, but due to a higher chlorophyll index the crop productivity increased.Since during the fruiting period the costs of assimilates to the growth of vegetative organs are greatly

  5. Talking about quality: exploring how 'quality' is conceptualized in European hospitals and healthcare systems.

    Science.gov (United States)

    Wiig, Siri; Aase, Karina; von Plessen, Christian; Burnett, Susan; Nunes, Francisco; Weggelaar, Anne Marie; Anderson-Gare, Boel; Calltorp, Johan; Fulop, Naomi

    2014-10-11

    Conceptualization of quality of care - in terms of what individuals, groups and organizations include in their meaning of quality, is an unexplored research area. It is important to understand how quality is conceptualised as a means to successfully implement improvement efforts and bridge potential disconnect in language about quality between system levels, professions, and clinical services. The aim is therefore to explore and compare conceptualization of quality among national bodies (macro level), senior hospital managers (meso level), and professional groups within clinical micro systems (micro level) in a cross-national study. This cross-national multi-level case study combines analysis of national policy documents and regulations at the macro level with semi-structured interviews (383) and non-participant observation (803 hours) of key meetings and shadowing of staff at the meso and micro levels in ten purposively sampled European hospitals (England, the Netherlands, Portugal, Sweden, and Norway). Fieldwork at the meso and micro levels was undertaken over a 12-month period (2011-2012) and different types of micro systems were included (maternity, oncology, orthopaedics, elderly care, intensive care, and geriatrics). The three quality dimensions clinical effectiveness, patient safety, and patient experience were incorporated in macro level policies in all countries. Senior hospital managers adopted a similar conceptualization, but also included efficiency and costs in their conceptualization of quality. 'Quality' in the forms of measuring indicators and performance management were dominant among senior hospital managers (with clinical and non-clinical background). The differential emphasis on the three quality dimensions was strongly linked to professional roles, personal ideas, and beliefs at the micro level. Clinical effectiveness was dominant among physicians (evidence-based approach), while patient experience was dominant among nurses (patient

  6. Implementation of a Quality Management System in regulatory inspection activities

    International Nuclear Information System (INIS)

    Pires do Rio, Monica; Ferreira, Paulo Roberto; Cunha, Paulo G. da; Acar, Maria Elizabeth

    2005-01-01

    The Institute for Radioprotection and Dosimetry - IRD -, of the Brazilian National Nuclear Energy Commission, CNEN, started in 2001, the implementation of a quality management system (SGQ), in the inspection, testing and calibration activities. The SGQ was an institutional guideline and is inserted in a larger system of management of the IRD started in 1999, with the adoption of the National Quality Award criteria - PNQ, within the Project for Excellence in Technological Research of Associacao Brasileira das Instituicoes de Pesquisas Tecnologicas - ABIPTI (Brazilian Association of Technological Research institutions). The proposed quality management system and adopted at the IRD was developed and implemented in accordance with the requirements of NBR ISO/IEC 17025 - General requirements for the competence of testing and calibration laboratories, and ISO/IEC 17020 - General criteria for operation of various types of bodies performing inspections. For regulatory inspection activities, the quality system was implemented on three program inspection services of radiological protection led, respectively, by clinics and hospitals that operate radiotherapy services; industries that use nuclear gauges in their control or productive processes and power reactor operators (CNAAA) - just the environmental part. It was formed a pioneering team of inspectors for standardizing the processes, procedures and starting the implementation of the system in the areas. This work describes the implementation process steps, including difficulties, learning and advantages of the adoption of a quality management system in inspection activities

  7. Are drowned donors marginal donors? A single pediatric center experience.

    Science.gov (United States)

    Kumm, Kayla R; Galván, N Thao N; Koohmaraie, Sarah; Rana, Abbas; Kueht, Michael; Baugh, Katherine; Hao, Liu; Yoeli, Dor; Cotton, Ronald; O'Mahony, Christine A; Goss, John A

    2017-09-01

    Drowning, a common cause of death in the pediatric population, is a potentially large donor pool for OLT. Anecdotally, transplant centers have deemed these organs high risk over concerns for infection and graft dysfunction. We theorized drowned donor liver allografts do not portend worse outcomes and therefore should not be excluded from the donation pool. We reviewed our single-center experience of pediatric OLTs between 1988 and 2015 and identified 33 drowned donor recipients. These OLTs were matched 1:2 to head trauma donor OLTs from our center. A chart review assessed postoperative peak AST and ALT, incidence of HAT, graft and recipient survival. Recipient survival at one year between patients with drowned donor vs head trauma donor allografts was not statistically significant (94% vs 97%, P=.63). HAT incidence was 6.1% in the drowned donor group vs 7.6% in the control group (P=.78). Mean postoperative peak AST and ALT was 683 U/L and 450 U/L for drowned donors vs 1119 U/L and 828 U/L in the matched cohort. These results suggest drowned donor liver allografts do not portend worse outcomes in comparison with those procured from head trauma donors. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Module-based quality system functionality evaluation in production logistics

    Energy Technology Data Exchange (ETDEWEB)

    Khabbazi, M.R.; Wikander, J.; Onori, M.; Maffei, A.; Chen, D.

    2016-07-01

    This paper addresses a comprehensive modeling and functionality evaluation of a module-based quality system in production logistics at the highest domain abstract level of business processes. All domain quality business processes and quality data transactions are modeled using BPMN and UML tools and standards at the business process and data modeling. A modular web-based prototype is developed to evaluate the models addressing the quality information system functionality requirements and modularity in production logistics through data scenarios and data queries. Using the object-oriented technique in design at the highest domain level, the proposed models are subject further development in the lower levels for the implementing case. The models are specifically able to manipulate all quality operations including remedy and control in a lot-based make-to-order production logistics system as an individual module. Due to the specification of system as domain design structure, all proposed BPMs, data models, and the actual database prototype are seen referential if not a solution as a practical “to-be” quality business process re-engineering template. This paper sets out to provide an explanatory approach using different practical technique at modeling steps as well as the prototype implementation. (Author)

  9. Using fertile couples as embryo donors: An ethical dilemma.

    Science.gov (United States)

    Alizadeh, Leila; Omani Samani, Reza

    2014-03-01

    The use of donated embryos has offered hope for infertile couples who have no other means to have children. In Iran, fertility centers use fertile couples as embryo donors. In this paper, the advantages and disadvantages of this procedure will be discussed. We conclude that embryo-donation should be performed with frozen embryos thus preventing healthy donors from being harmed by fertility drugs. There must be guidelines for choosing the appropriate donor families. In countries where commercial egg donation is acceptable, fertile couples can be procured as embryo donors thus fulfilling the possible shortage of good quality embryos. Using frozen embryos seems to have less ethical, religious and legal problems when compared to the use of fertile embryo donors.

  10. On the effect of nuclear bridge modes on donor-acceptor electronic coupling in donor-bridge-acceptor molecules

    International Nuclear Information System (INIS)

    Davis, Daly; Toroker, Maytal Caspary; Speiser, Shammai; Peskin, Uri

    2009-01-01

    We report a theoretical study of intra-molecular electronic coupling in a symmetric DBA (donor-bridge-acceptor) complex, in which a donor electronic site is coupled to an acceptor site by way of intervening orbitals of a molecular bridge unit. In the off-resonant (deep tunneling) regime of electronic transport, the lowest unoccupied molecular orbitals (MO's) of the DBA system are split into distinguishable donor/acceptor and bridge orbitals. The effect of geometrical changes at the bridge on the donor/acceptor electronic energy manifold is studied for local stretching and bending modes. It is demonstrated that the energy splitting in the manifold of donor/acceptor unoccupied MOs changes in response to such changes, as assumed in simple McConnell-type models. Limitations of the simple models are revealed where the electronic charging of the bridge orbitals correlates with increasing donor/acceptor orbital energy splitting only for stretching but not for bending bridge modes.

  11. Systems and software quality the next step for industrialisation

    CERN Document Server

    Wieczorek, Martin; Bons, Heinz

    2014-01-01

    Software and systems quality is playing an increasingly important role in the growth of almost all - profit and non-profit - organisations. Quality is vital to the success of enterprises in their markets. Most small trade and repair businesses use software systems in their administration and marketing processes. Every doctor's surgery is managing its patients using software. Banking is no longer conceivable without software. Aircraft, trucks and cars use more and more software to handle their increasingly complex technical systems. Innovation, competition and cost pressure are always present i

  12. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  13. Operation quality assessment model for video conference system

    Science.gov (United States)

    Du, Bangshi; Qi, Feng; Shao, Sujie; Wang, Ying; Li, Weijian

    2018-01-01

    Video conference system has become an important support platform for smart grid operation and management, its operation quality is gradually concerning grid enterprise. First, the evaluation indicator system covering network, business and operation maintenance aspects was established on basis of video conference system's operation statistics. Then, the operation quality assessment model combining genetic algorithm with regularized BP neural network was proposed, which outputs operation quality level of the system within a time period and provides company manager with some optimization advice. The simulation results show that the proposed evaluation model offers the advantages of fast convergence and high prediction accuracy in contrast with regularized BP neural network, and its generalization ability is superior to LM-BP neural network and Bayesian BP neural network.

  14. Breast milk donation: women's donor experience.

    Science.gov (United States)

    Alencar, Lucienne Christine Estevez de; Seidl, Eliane Maria Fleury

    2009-02-01

    To describe the characteristics of donation behavior and identify reasons, beliefs and feelings relative to this practice, based on the reports of donor women. Personal and social-environmental aspects, which seem to affect donation behavior in donors and former donors, were also investigated. An exploratory, descriptive and cross-sectional study was carried out with women donors at two breast-milk banks within the public health system of the Brazilian Federal District. Data was collected from July to September 2005. The participants were 36 women, aged 14 to 33 years (average=24.78; SD=5.22), with different levels of schooling, 58.3% of which were first-time mothers. Data gathering was based on interviews carried out during home visits. In addition to descriptive statistical analyses of quantitative data, a qualitative data categorical analysis was also performed. The most frequently reported reasons for donating breast milk were altruism and excess milk production. The most frequent time interval for donation was 13 days after delivery. Contact by phone with the milk bank was the most common means of communication used by the majority of participants (n=22) to obtain information that enabled the donating process. Psychosocial aspects identified and the experience of donors can contribute to the empowerment of the formal and informal social donation-support network, in addition to serving as a driver for the implementation of technical and policy strategies in promoting future donation practices.

  15. Astronomical Instrumentation Systems Quality Management Planning: AISQMP (Abstract)

    Science.gov (United States)

    Goldbaum, J.

    2017-12-01

    (Abstract only) The capability of small aperture astronomical instrumentation systems (AIS) to make meaningful scientific contributions has never been better. The purpose of AIS quality management planning (AISQMP) is to ensure the quality of these contributions such that they are both valid and reliable. The first step involved with AISQMP is to specify objective quality measures not just for the AIS final product, but also for the instrumentation used in its production. The next step is to set up a process to track these measures and control for any unwanted variation. The final step is continual effort applied to reducing variation and obtaining measured values near optimal theoretical performance. This paper provides an overview of AISQMP while focusing on objective quality measures applied to astronomical imaging systems.

  16. ISO/TS 16949 system in quality aspect

    Directory of Open Access Journals (Sweden)

    Joanna Rosak-Szyrocka

    2014-12-01

    Full Text Available In the automotive industry the use of modern technology and provision of the highest quality product and related services is the most important element of rivalry between global corporations and motorcycles. In a competitive struggle for the recognition of its brand in the automotive market global organizations continuously raise the requirements for quality management systems, so that the finished product meets all the standards in terms of safety, quality and satisfying the ever-growing needs of customers - present and future drivers and passengers of cars. ISO/TS 16949 quality management system is presented in the paper. A framework for customer specific requirement as well as preventing problems is shown.

  17. Application of quality assurance to MC and A systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Application of the principles of quality assurance to MC and A has been done at DOE's Savannah River Operations Office. The principles were applied to the functions within the MC and A Branch, including both the functions used to operate the Branch and those used to review the MC and A activities of DOE/SR's contractor. The purpose of this paper is to discuss that application of quality assurance and to show how the principles of quality assurance relate to the functions of a MC and A system, for both a DOE field office and a contractor. The principles (presented as requirements from the NQA-1 standard) are briefly discussed, a method for applying quality assurance is outlined, application at DOE/SR is shown, and application to a contractor's MC and A system is discussed

  18. Quality assurance systems – the difficulties in providing a global unified system for Surveyors

    OpenAIRE

    Goodhead, Tim

    2012-01-01

    This paper will analyse the difficulties in providing a global quality assurance system for Surveyors. Using case studies from the United Kingdom and elsewhere opportunities for harmonising Quality Assurance systems will be explored. The difficulties in moving towards common quality assurance systems will be analysed. Possible alternatives in the form of the development a knowledge bank of mutual agreements and top up qualifications will be investigated. The paper also looks at the role of FI...

  19. Self-Assembled Core-Shell CdTe/Poly(3-hexylthiophene) Nanoensembles as Novel Donor-Acceptor Light-Harvesting Systems.

    Science.gov (United States)

    Istif, Emin; Kagkoura, Antonia; Hernandez-Ferrer, Javier; Stergiou, Anastasios; Skaltsas, Theodosis; Arenal, Raul; Benito, Ana M; Maser, Wolfgang K; Tagmatarchis, Nikos

    2017-12-27

    The self-assembly of novel core-shell nanoensembles consisting of regioregular poly(3-hexylthiophene) nanoparticles (P3HT NPs ) of 100 nm as core and semiconducting CdTe quantum dots (CdTe QDs ) as shell with a thickness of a few tens of nanometers was accomplished by employing a reprecipitation approach. The structure, morphology, and composition of CdTe QDs /P3HT NPs nanoensembles were confirmed by high-resolution scanning transmission microscopy and dynamic light-scattering studies. Intimate interface contact between the CdTe QDs shell and the P3HT NPs core leads to the stabilization of the CdTe QDs /P3HT NPs nanoensemble as probed by the steady-state absorption spectroscopy. Effective quenching of the characteristic photoluminescence of CdTe QDs at 555 nm, accompanied by simultaneous increase in emission of P3HT NPs at 660 and 720 nm, reveals photoinduced charge-transfer processes. Probing the redox properties of films of CdTe QDs /P3HT NPs further proves the formation of a stabilized core-shell system in the solid state. Photoelectrochemical assays on CdTe QDs /P3HT NPs films show a reversible on-off photoresponse at a bias voltage of +0.8 V with a 3 times increased photocurrent compared to CdTe QDs . The improved charge separation is directly related to the unique core-shell configuration, in which the outer CdTe QDs shell forces the P3HT NPs core to effectively act as electron acceptor. The creation of novel donor-acceptor core-shell hybrid materials via self-assembly is transferable to other types of conjugated polymers and semiconducting nanoparticles. This work, therefore, opens new pathways for the design of improved optoelectronic devices.

  20. Online information system for data collection of cattle quality

    Science.gov (United States)

    Sugiharti, E.; Arifudin, R.; Putra, A. T.

    2018-03-01

    Innovation and development of the science and technology which proclaimed by the government through Ristekdikti need to be supported. On the other hand, the Department of Animal Husbandry and Fisheries began introducing the Cattle Card system that contains the identity of each farm animal. Therefore, UNNES especially the Department of Computer Science of FMIPA UNNES, need to give positive contribution in the field of Science and Technology to support the manual system of Cattle Card, through the preparation of prototype of the online information system of data collection of cattle in Semarang regency. The main problem is how to monitor the data of cattle quality through online information system in Semarang regency? The purpose of this research is to produce the prototype of an online information system for data collection of cattle quality in Semarang regency. Main activities: (1) Prepare the flowchart of an online system for data collection of cattle quality. (2) Collecting data to obtain data on identity descriptions of each cattle, owners, mutation records, and health records of livestock cattle. (3) Creation of the prototype of an online information system for data collection of cattle quality in Semarang Regency. The results, (1) had been produced the prototype of an online information system for data collection of cattle in the region of Semarang regency. (2) Socialization of the online information system for cattle quality data collection and exploring input from various related stakeholders. (3) There had been a limited trial of prototypes of the system in Pabelan district in the working area of the Department of Animal Husbandry and Fisheries of Semarang regency and succeeded well.

  1. Working with previously anonymous gamete donors and donor-conceived adults: recent practice experiences of running the DNA-based voluntary information exchange and contact register, UK DonorLink.

    Science.gov (United States)

    Crawshaw, Marilyn; Gunter, Christine; Tidy, Christine; Atherton, Freda

    2013-03-01

    This article describes recent practice experiences with donor conceived adults, donors, non-donor-conceived adult children of donors using the voluntary DNA-based register, UK DonorLink. It highlights additional complexities faced when using DNA rather than paper records for searching, in particular from the risk of false positives, low chances of success and potential inclusion of biological parents' DNA. Professionals' experiences in supporting those being "linked" suggest challenges as well as rewards. Registration carries the potential to be therapeutic for donor-conceived adults and donors and to enhance their political awareness regardless of links being made. Registrants value both peer and professional support, providing the latter can respond flexibly and be delivered by staff experienced in intermediary work. Given that the majority of those affected by donor conception internationally come from anonymous donation systems, these findings are highly pertinent and argue the need for political and moral debate about such service provision.

  2. Human Factors in Software Development Processes: Measuring System Quality

    DEFF Research Database (Denmark)

    Abrahão, Silvia; Baldassarre, Maria Teresa; Caivano, Danilo

    2016-01-01

    Software Engineering and Human-Computer Interaction look at the development process from different perspectives. They apparently use very different approaches, are inspired by different principles and address different needs. But, they definitively have the same goal: develop high quality software...... in the most effective way. The second edition of the workshop puts particular attention on efforts of the two communities in enhancing system quality. The research question discussed is: who, what, where, when, why, and how should we evaluate?...

  3. Effectiveness of Quality Management System (QMS) on Construction Projects

    OpenAIRE

    Behnam Neyestani

    2016-01-01

    Quality management system (QMS) provides generic guidance and requirements for establishing an appropriate quality management procedure, in order to lower cost, increase productivity, customer's satisfaction, and market share in the organizations since the last two-decade. In construction industry, it can assist the companies to achieve successfully their objectives, and ensure that all phases of construction project consistently meet client's requirements (need). The main aim of this article...

  4. [Clinical trial data management and quality metrics system].

    Science.gov (United States)

    Chen, Zhao-hua; Huang, Qin; Deng, Ya-zhong; Zhang, Yue; Xu, Yu; Yu, Hao; Liu, Zong-fan

    2015-11-01

    Data quality management system is essential to ensure accurate, complete, consistent, and reliable data collection in clinical research. This paper is devoted to various choices of data quality metrics. They are categorized by study status, e.g. study start up, conduct, and close-out. In each category, metrics for different purposes are listed according to ALCOA+ principles such us completeness, accuracy, timeliness, traceability, etc. Some general quality metrics frequently used are also introduced. This paper contains detail information as much as possible to each metric by providing definition, purpose, evaluation, referenced benchmark, and recommended targets in favor of real practice. It is important that sponsors and data management service providers establish a robust integrated clinical trial data quality management system to ensure sustainable high quality of clinical trial deliverables. It will also support enterprise level of data evaluation and bench marking the quality of data across projects, sponsors, data management service providers by using objective metrics from the real clinical trials. We hope this will be a significant input to accelerate the improvement of clinical trial data quality in the industry.

  5. [Real-time feedback systems for improvement of resuscitation quality].

    Science.gov (United States)

    Lukas, R P; Van Aken, H; Engel, P; Bohn, A

    2011-07-01

    The quality of chest compression is a determinant of survival after cardiac arrest. Therefore, the European Resuscitation Council (ERC) 2010 guidelines on resuscitation strongly focus on compression quality. Despite its impact on survival, observational studies have shown that chest compression quality is not reached by professional rescue teams. Real-time feedback devices for resuscitation are able to measure chest compression during an ongoing resuscitation attempt through a sternal sensor equipped with a motion and pressure detection system. In addition to the electrocardiograph (ECG) ventilation can be detected by transthoracic impedance monitoring. In cases of quality deviation, such as shallow chest compression depth or hyperventilation, feedback systems produce visual or acoustic alarms. Rescuers can thereby be supported and guided to the requested quality in chest compression and ventilation. Feedback technology is currently available both as a so-called stand-alone device and as an integrated feature in a monitor/defibrillator unit. Multiple studies have demonstrated sustainable enhancement in the education of resuscitation due to the use of real-time feedback technology. There is evidence that real-time feedback for resuscitation combined with training and debriefing strategies can improve both resuscitation quality and patient survival. Chest compression quality is an independent predictor for survival in resuscitation and should therefore be measured and documented in further clinical multicenter trials.

  6. Iron deficiency in blood donors

    Directory of Open Access Journals (Sweden)

    Rodolfo Delfini Cançado

    Full Text Available CONTEXT: Blood donation results in a substantial loss of iron (200 to 250 mg at each bleeding procedure (425 to 475 ml and subsequent mobilization of iron from body stores. Recent reports have shown that body iron reserves generally are small and iron depletion is more frequent in blood donors than in non-donors. OBJECTIVE: The aim of this study was to evaluate the frequency of iron deficiency in blood donors and to establish the frequency of iron deficiency in blood donors according to sex, whether they were first-time or multi-time donors, and the frequency of donations per year. DESIGN: From September 20 to October 5, 1999, three hundred blood donors from Santa Casa Hemocenter of São Paulo were studied. DIAGNOSTIC TESTS: Using a combination of biochemical measurements of iron status: serum iron, total iron-binding capacity, transferrin saturation index, serum ferritin and the erythrocyte indices. RESULTS: The frequency of iron deficiency in blood donors was 11.0%, of whom 5.5% (13/237 were male and 31.7% (20/63 female donors. The frequency of iron deficiency was higher in multi-time blood donors than in first-time blood donors, for male blood donors (7.6% versus 0.0%, P < 0.05 and female ones (41.5% versus 18.5%, P < 0.05. The frequency of iron deficiency found was higher among the male blood donors with three or more donations per year (P < 0.05 and among the female blood donors with two or more donations per year (P < 0.05. CONCLUSIONS: We conclude that blood donation is a very important factor for iron deficiency in blood donors, particularly in multi-time donors and especially in female donors. The high frequency of blood donors with iron deficiency found in this study suggests a need for a more accurate laboratory trial, as hemoglobin or hematocrit measurement alone is not sufficient for detecting and excluding blood donors with iron deficiency without anemia.

  7. Fermilab Friends for Science Education | Programs | Past Donors

    Science.gov (United States)

    Fermilab Friends for Science Education FFSE Home About Us Join Us Support Us Contact Us Our Donors Testimonials Our Donors Board of Directors Board Tools Calendar Join Us Donate Now Get FermiGear! Education DuPage Area Occupational Education Systems Technology Center DuPage/Kane Educational Service Center Fermi

  8. THE QUALITY MANAGEMENT SYSTEM AT THE UNIVERSITY. PROBLEMS IN IMPLEMENTING

    Directory of Open Access Journals (Sweden)

    L. I. Nazina

    2014-01-01

    Full Text Available Summary. Beginning of the XXI century marked the active integration of Russia and the world community, including entry into the world educational space. The international activities of the leading universities of the country depends on the level of cooperation with foreign countries in the field of scientific and educational activities. Today topical issue recognition of the quality of Russian education abroad. One way to confirm this is the certification of the quality management system of the university. As long-term, mostly foreign experience, achieving the required level of quality and continue to improve the most productive is accomplished by implementing a quality management system in accordance with ISO 9000. In the modern system of higher education a lot of attention paid to quality, to ensure the competitiveness of the institution in the education market by training qualified specialists. Implementation of the quality management system is to move the university to process management prepared in accordance with approved and enacted by the QMS documents. Workplaces should determine the duties, powers and responsibilities of each employee within the quality management system, develop and implement the job descriptions, staff verify documented procedures. Implementation of the certification must be accompanied by specific and persistent administration by management in conjunction with the training and retraining of all managers and employees involved in the work on the implementation of the QMS in the organization. This article describes the goals, objectives in the formation and implementation of QMS in higher education arising from this problem and barriers (information, methodological, psychological, multiple ways to address them.

  9. Indoor air quality environmental information handbook: Building system characteristics

    International Nuclear Information System (INIS)

    1987-01-01

    This manual, the third in a series, focuses on residential building system characteristics and their effects on indoor air quality. The manual addresses: residential indoor air pollutants by source, indoor concentrations, health effects, source control and mitigation techniques, standards and guidelines; building system characteristics of air exchange, pollutant source strength, residence volume, site characteristics, structural design, construction, and operation, infiltration and ventilation system, building occupancy; and monitoring methods

  10. LOGISTIC SYSTEM OF LOAD DELIVERY AND QUALITY OF ITS OPERATION

    Directory of Open Access Journals (Sweden)

    O. G. Drozdovskaya

    2006-01-01

    Full Text Available The paper considers an opportunity for obtaining a competitive advantage by a transport and dispatch service company in the market of transport services while establishing a logistic system of load delivery. A model of delivery system, an universal scheme of system designing for every specific case are presented and also indices for evaluation of its operational quality are proposed in the paper.

  11. Increasing the pool of deceased donor organs for kidney transplantation.

    Science.gov (United States)

    Schold, Jesse D; Segev, Dorry L

    2012-03-27

    Expanding the pool of available deceased donor kidneys is critical for improving the outcomes of prospective and current renal transplant candidates. A number of interventions have been proposed that may increase the pool of donors in the US. However, these interventions have variable levels of empirical evidence supporting their potential beneficial impact. Proposed interventions include the instigation of policies for presumed donor consent, the expansion of donor registration, increased quality oversight of transplant providers, financial incentives for donors, increased reimbursement for higher risk donors, alterations in organ allocation policies and distribution, and the selective use of donors with potential or known risk for disease transmission. Many of these interventions have contentious elements that may have delayed or impeded their implementation; however, these options should be considered in the context of the diminishing prognoses for prospective transplant patients, given the increasing scarcity of donor organs relative to the population need. In this Review, we outline the proposed interventions and briefly discuss salient issues that characterize the debates concerning their implementation and effectiveness. Ultimately, any intervention must be based on the best evidence available, with consideration of numerous stakeholders and in conjunction with a careful evaluation of long-term and potential unintended consequences.

  12. Review of power quality applications of energy storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Swaminathan, S.; Sen, R.K. [Sentech, Inc., Bethesda, MD (United States)

    1997-05-01

    Under the sponsorship of the US Department of Energy (DOE) Office of Utility Technologies, the Energy Storage Systems Analysis and Development Department at Sandia National Laboratories contracted Sentech, Inc., to assess the impact of power quality problems on the electricity supply system. This report contains the results of several studies that have identified the cost of power quality events for electricity users and providers. The large annual cost of poor power quality represents a national inefficiency and is reflected in the cost of goods sold, reducing US competitiveness. The Energy Storage Systems (ESS) Program takes the position that mitigation merits the attention of not only the DOE but affected industries as well as businesses capable of assisting in developing solutions to these problems. This study represents the preliminary stages of an overall strategy by the ESS Program to understand the magnitude of these problems so as to begin the process of engaging industry partners in developing solutions.

  13. Quality Service Evaluation through the System of Complaints and Praise

    Directory of Open Access Journals (Sweden)

    Elizabeta Krstić Vukelja

    2014-01-01

    Full Text Available Complaint, as the expression of customer dissatisfaction with the quality of products or services, is very valuable information. Well-built system for collecting, processing and analysis of complaints allows organizations to create the information base for making decisions based on facts. This data base provides an effective adoption and implementation of measures for continuous improvement of products/services quality. To make the system work effectively, it is necessary to continuously use the same methodology for collecting and processing complaints to be able constant comparisons from period to period. Greater investment in quality of products/services does not mean reducing the number of complaints in the same time due to the effects of the phenomenon of “unrealistic expectations”. In addition to complaints, a valuable source of information on customer satisfaction is the system of praise.

  14. Image quality assessment for video stream recognition systems

    Science.gov (United States)

    Chernov, Timofey S.; Razumnuy, Nikita P.; Kozharinov, Alexander S.; Nikolaev, Dmitry P.; Arlazarov, Vladimir V.

    2018-04-01

    Recognition and machine vision systems have long been widely used in many disciplines to automate various processes of life and industry. Input images of optical recognition systems can be subjected to a large number of different distortions, especially in uncontrolled or natural shooting conditions, which leads to unpredictable results of recognition systems, making it impossible to assess their reliability. For this reason, it is necessary to perform quality control of the input data of recognition systems, which is facilitated by modern progress in the field of image quality evaluation. In this paper, we investigate the approach to designing optical recognition systems with built-in input image quality estimation modules and feedback, for which the necessary definitions are introduced and a model for describing such systems is constructed. The efficiency of this approach is illustrated by the example of solving the problem of selecting the best frames for recognition in a video stream for a system with limited resources. Experimental results are presented for the system for identity documents recognition, showing a significant increase in the accuracy and speed of the system under simulated conditions of automatic camera focusing, leading to blurring of frames.

  15. [Vascular anatomy of donor and recipient in living kidney transplantation].

    Science.gov (United States)

    Zhang, Jiqing; Zhang, Xiaodong

    2009-09-01

    To review the vascular anatomy of the donor and the recipient for the living kidney transplantation. The recent literature about the vessels of donor and recipient in clinical applications was extensively reviewed. The pertinent vascular anatomy of the donor and recipient was essential for the screening of the proper candidates, surgical planning and long-term outcome. Early branching and accessory renal artery of the donor were particularly important to deciding the side of nephrectomy, surgical technique and anastomosing pattern, and their injuries were the most frequent factor of the conversion from laparoscopic to open surgery. With increase of laparoscopic nephrectomy in donors, accurate venous anatomy was paid more and more attention to because venous bleeding could also lead to conversion to open nephrectomy. Multidetector CT (MDCT) could supplant the conventional excretory urography and renal catheter angiography and could accurately depict the donors' vessels, vascular variations. In addition, MDCT can excellently evaluate the status of donor kidney, collecting system and other pertinent anatomy details. Accurate master of related vascular anatomy can facilitate operation plan and success of operation and can contribute to the rapid development of living donor kidney transplantation. MDCT has become the choice of preoperative one-stop image assessment for living renal donors.

  16. Asan medical information system for healthcare quality improvement.

    Science.gov (United States)

    Ryu, Hyeon Jeong; Kim, Woo Sung; Lee, Jae Ho; Min, Sung Woo; Kim, Sun Ja; Lee, Yong Su; Lee, Young Ha; Nam, Sang Woo; Eo, Gi Seung; Seo, Sook Gyoung; Nam, Mi Hyun

    2010-09-01

    This purpose of this paper is to introduce the status of the Asan Medical Center (AMC) medical information system with respect to healthcare quality improvement. Asan Medical Information System (AMIS) is projected to become a completely electronic and digital information hospital. AMIS has played a role in improving the health care quality based on the following measures: safety, effectiveness, patient-centeredness, timeliness, efficiency, privacy, and security. AMIS CONSISTED OF SEVERAL DISTINCTIVE SYSTEMS: order communication system, electronic medical record, picture archiving communication system, clinical research information system, data warehouse, enterprise resource planning, IT service management system, and disaster recovery system. The most distinctive features of AMIS were the high alert-medication recognition & management system, the integrated and severity stratified alert system, the integrated patient monitoring system, the perioperative diabetic care monitoring and support system, and the clinical indicator management system. AMIS provides IT services for AMC, 7 affiliated hospitals and over 5,000 partners clinics, and was developed to improve healthcare services. The current challenge of AMIS is standard and interoperability. A global health IT strategy is needed to get through the current challenges and to provide new services as needed.

  17. Development of Quality Management Systems: How Have Disruptive Technological Innovations in Quality Management Affected Organizations?

    Directory of Open Access Journals (Sweden)

    Pasi Hellman

    2013-07-01

    Full Text Available This research investigates the history of quality and development of quality management systems. History of quality is investigated from Hammurabi’s law all the way to today’s reigning quality initiatives including ISO, Six Sigma and Lean manufacturing. In the last chapters the current state of quality management is being examined. The foresight method is also opened up and examined. The Innovator’s dilemma concept, originally presented by Clayton Christensen, is used to analyse how quality management systems have been evolved in the last 100 years. Special emphasis is placed on the US manufacturing in the 1970s and 1980s. Based on the literature, the concept of Innovator’s dilemma and the fall of US manufacturing are merged. The result is a prime example that the Innovator’s Dilemma is a universal phenomenon. The industry leader is trying to maintain its position and do everything right but still it is destined to fail. The causes and effects are being discussed in later chapters.

  18. Implementing hospital quality assurance policies in Iran: balancing licensing, annual evaluation, inspections and quality management systems.

    Science.gov (United States)

    Aghaei Hashjin, Asgar; Delgoshaei, Bahram; Kringos, Dionne S; Tabibi, Seyed Jamaladin; Manouchehri, Jila; Klazinga, Niek S

    2015-01-01

    The purpose of this paper is to provide an overview of applied hospital quality assurance (QA) policies in Iran. A mixed method (quantitative data and qualitative document analysis) study was carried out between 1996 and 2010. The QA policy cycle forms a tight monitoring system to assure hospital quality by combining mandatory and voluntary methods in Iran. The licensing, annual evaluation and grading, and regulatory inspections statutorily implemented by the government as a national package to assure and improve hospital care quality, while implementing quality management systems (QMS) was voluntary for hospitals. The government's strong QA policy legislation role and support has been an important factor for successful QA implementation in Iran, though it may affected QA assessment independency and validity. Increased hospital evaluation independency and repositioning, updating standards, professional involvement and effectiveness studies could increase QA policy impact and maturity. The study highlights the current QA policy implementation cycle in Iranian hospitals. It provides a basis for further quality strategy development in Iranian hospitals and elsewhere. It also raises attention about finding the optimal balance between different QA policies, which is topical for many countries. This paper describes experiences when implementing a unique approach, combining mandatory and voluntary QA policies simultaneously in a developing country, which has invested considerably over time to improve hospital quality. The experiences with a mixed obligatory/voluntary approach and comprehensive policies in Iran may contain lessons for policy makers in developing and developed countries.

  19. Lean management systems: creating a culture of continuous quality improvement.

    Science.gov (United States)

    Clark, David M; Silvester, Kate; Knowles, Simon

    2013-08-01

    This is the first in a series of articles describing the application of Lean management systems to Laboratory Medicine. Lean is the term used to describe a principle-based continuous quality improvement (CQI) management system based on the Toyota production system (TPS) that has been evolving for over 70 years. Its origins go back much further and are heavily influenced by the work of W Edwards Deming and the scientific method that forms the basis of most quality management systems. Lean has two fundamental elements--a systematic approach to process improvement by removing waste in order to maximise value for the end-user of the service and a commitment to respect, challenge and develop the people who work within the service to create a culture of continuous improvement. Lean principles have been applied to a growing number of Healthcare systems throughout the world to improve the quality and cost-effectiveness of services for patients and a number of laboratories from all the pathology disciplines have used Lean to shorten turnaround times, improve quality (reduce errors) and improve productivity. Increasingly, models used to plan and implement large scale change in healthcare systems, including the National Health Service (NHS) change model, have evidence-based improvement methodologies (such as Lean CQI) as a core component. Consequently, a working knowledge of improvement methodology will be a core skill for Pathologists involved in leadership and management.

  20. The tissue bank at the Instituto Nacional de Investigaciones Nucleares: ISO 9001:2000 certification of its quality management system.

    Science.gov (United States)

    Martínez-Pardo, María Esther; Mariano-Magaña, David

    2007-01-01

    Tissue banking is a complex operation concerned with the organisation and coordination of all the steps, that is, from donor selection up to storage and distribution of the final products for therapeutic, diagnostic, instruction and research purposes. An appropriate quality framework should be established in order to cover all the specific methodology as well as the general aspects of quality management, such as research and development, design, instruction and training, specific documentation, traceability, corrective action, client satisfaction, and the like. Such a framework can be obtained by developing a quality management system (QMS) in accordance with a suitable international standard: ISO 9001:2000. This paper presents the implementation process of the tissue bank QMS at the Instituto Nacional de Investigaciones Nucleares in Mexico. The objective of the paper is to share the experience gained by the tissue bank personnel [radiosterilised tissue bank (BTR)] at the Instituto Nacional de Investigaciones Nucleares (ININ, National Institute of Nuclear Research), during implementation of the ISO 9001:2000 certification process. At present, the quality management system (QMS) of ININ also complies with the Mexican standard NMX-CC-9001:2000. The scope of this QMS is Research, Development and Processing of Biological Tissues Sterilised by Gamma Radiation, among others.

  1. ِAnalysis of donor motivations in living donor liver transplantation

    Directory of Open Access Journals (Sweden)

    Hesham eAbdeldayem

    2014-07-01

    Full Text Available Objectives: The introduction of the living donor liver transplantation (LDLT in Egypt as in elsewhere, has raised important psychological conflicts and ethical questions. The objective of this study was to get better understanding of the potential donors’ motives towards LDLT.Methods:This study was conducted on consecutive 193 living –liver donors who underwent partial hepatectomy as donors for LDLT during the period between April 2003 and January 2013, at the National Liver Institute Menoufeyia University, Egypt. Potential donors were thoroughly evaluated preoperatively through a screening questionnaire and interviews as regard their demographic data, relationship to the potential recipient and motives towards proceeding to surgery. They were assured that the information shared between them and the transplant centre is confidential. Results.The donors’ mean age was 25.53± 6.39 years with a range of 18-45 years. Males represented 64.7 % and females were 35.3%. The most common donors (32.1%, n_62, were sons and daughters to their parents (sons: n_43, daughters: n_19 while parents to their offsprings represent 15% (mothers: n_21, fathers: n_8. Brothers and sisters represent 16.5 % (brothers: n_22, sisters: n_10. Nephews & nieces giving their uncles or aunts were 14%. The number of wives donating to their husbands was 11 (5.7%. Interestingly, there was no single husband who donated his wife. Among the remaining donors, there were 11 cousins & one uncle. Unrelated donors were 20 (10.4%. Several factors seemed to contribute to motivation for donation: the seriousness of the potential recipient condition, the relationship and personal history of the donor to the potential recipient, the religious beliefs, the trust in the health care system, and family dynamics and obligations.Conclusions. Absolute absence of coercion on the living-liver donor’s motives may not be realistic because of the serious condition of the potential recipient. It is

  2. Using a web-based image quality assurance reporting system to improve image quality.

    Science.gov (United States)

    Czuczman, Gregory J; Pomerantz, Stuart R; Alkasab, Tarik K; Huang, Ambrose J

    2013-08-01

    The purpose of this study is to show the impact of a web-based image quality assurance reporting system on the rates of three common image quality errors at our institution. A web-based image quality assurance reporting system was developed and used beginning in April 2009. Image quality endpoints were assessed immediately before deployment (period 1), approximately 18 months after deployment of a prototype reporting system (period 2), and approximately 12 months after deployment of a subsequent upgraded department-wide reporting system (period 3). A total of 3067 axillary shoulder radiographs were reviewed for correct orientation, 355 shoulder CT scans were reviewed for correct reformatting of coronal and sagittal images, and 346 sacral MRI scans were reviewed for correct acquisition plane of axial images. Error rates for each review period were calculated and compared using the Fisher exact test. Error rates of axillary shoulder radiograph orientation were 35.9%, 7.2%, and 10.0%, respectively, for the three review periods. The decrease in error rate between periods 1 and 2 was statistically significant (p < 0.0001). Error rates of shoulder CT reformats were 9.8%, 2.7%, and 5.8%, respectively, for the three review periods. The decrease in error rate between periods 1 and 2 was statistically significant (p = 0.03). Error rates for sacral MRI axial sequences were 96.5%, 32.5%, and 3.4%, respectively, for the three review periods. The decrease in error rates between periods 1 and 2 and between periods 2 and 3 was statistically significant (p < 0.0001). A web-based system for reporting image quality errors may be effective for improving image quality.

  3. CASE STUDY ON WATER QUALITY CONTROL IN AN AQUAPONIC SYSTEM

    Directory of Open Access Journals (Sweden)

    Radu Mihai Filep

    2016-07-01

    Full Text Available Aquaponic systems are integrated systems that combine fish farming and different types of plants. It involves a dynamic interaction between fish plants and bacteria. Fish and plants are dependent the equilibrium of dissolved nutrients and water quality. Only by striking a balance between dissolved nutrients and water quality we can achieve a large production of plants and healthy fish. Thus, control of water quality in an aquaponic system is essential in order to obtain performance in raising fish and plants. The experiment was conducted in the laboratory of Fisheries and Aquaculture of the Faculty of Animal Science of the University of Agronomic Sciences and Veterinary Medicine of Bucharest within a period of 30 days. The system used for the experiment was designed and developed in the laboratory mentioned above. The plant used for water treatment in the system was basil (Ocimum basilicum. Fish species grown in the system was culture carp (Cyprinus carpio. Indicators measured to assess water quality in the system were: temperature, pH, dissolved oxygen, total ammonia, nitrites, nitrates and phosphates. The values determined pH 7.4-7.6, dissolved oxygen 8-10 mg / l, NH4 0.05-05 mg/ l, NO2 0.1-3.2 mg / l, NO3 0-80 mg / l, 0.02-0.3 mg, PO4 0.02-0.3 mg/l were not too high. In conclusion it was demonstrated that water quality in the aquaponic system studied is propitious to the growth and welfare of fish the registered values are not to be harmful.

  4. Lead/acid batteries in systems to improve power quality

    Science.gov (United States)

    Taylor, P.; Butler, P.; Nerbun, W.

    Increasing dependence on computer technology is driving needs for extremely high-quality power to prevent loss of information, material, and workers' time that represent billions of dollars annually. This cost has motivated commercial and Federal research and development of energy storage systems that detect and respond to power-quality failures in milliseconds. Electrochemical batteries are among the storage media under investigation for these systems. Battery energy storage systems that employ either flooded lead/acid or valve-regulated lead/acid battery technologies are becoming commercially available to capture a share of this emerging market. Cooperative research and development between the US Department of Energy and private industry have led to installations of lead/acid-based battery energy storage systems to improve power quality at utility and industrial sites and commercial development of fully integrated, modular battery energy storage system products for power quality. One such system by AC Battery Corporation, called the PQ2000, is installed at a test site at Pacific Gas and Electric Company (San Ramon, CA, USA) and at a customer site at Oglethorpe Power Corporation (Tucker, GA, USA). The PQ2000 employs off-the-shelf power electronics in an integrated methodology to control the factors that affect the performance and service life of production-model, low-maintenance, flooded lead/acid batteries. This system, and other members of this first generation of lead/acid-based energy storage systems, will need to compete vigorously for a share of an expanding, yet very aggressive, power quality market.

  5. Wind energy systems solutions for power quality and stabilization

    CERN Document Server

    Ali, Mohd Hasan

    2012-01-01

    Unlike conventional power plants, wind plants emit no air pollutants or greenhouse gases--and wind energy is a free, renewable resource. However, the induction machines commonly used as wind generators have stability problems similar to the transient stability of synchronous machines. To minimize power, frequency, and voltage fluctuations caused by network faults or random wind speed variations, control mechanisms are necessary. Wind Energy Systems: Solutions for Power Quality and Stabilization clearly explains how to solve stability and power quality issues of wind generator systems. Covering

  6. Power Quality Improvements in Wind Diesel Power Generation System

    Directory of Open Access Journals (Sweden)

    Omar Feddaoui

    2015-08-01

    Full Text Available Generation of electricity using diesel is costly for small remote isolated communities. At remote location electricity generation from renewable energy such as wind can help reduce the overall operating costs by reducing the fuel costs. However, the penetration of wind power into small diesel-based grids is limited because of its effect on power quality and reliability. This paper focuses on the combination of Wind Turbine and Diesel Generator systems for sustained power generation, to improve the power quality of wind generation system. The performances of the optimal control structure are assessed and discussed by means of a set of simulations.

  7. Intelligent quality function deployment system in concurrent engineering environment

    Science.gov (United States)

    Lin, Zhihang; Che, Ada

    1998-10-01

    This paper describes work being undertaken in the development of an intelligent distributed quality function deployment (IDQFD) system, which supports product design team to transfer and deployment the `Voice of Customer' through `House of Quality' into the various stages of product planning, engineering and manufacturing. The requirement modeling of products, the optimization in QFD are indicated. The framework of the system, including QFD tools and platform for distributed collaborative work in QFD, is described. The strategy and methods for the collaboration processing in QFD process are presented. It shows promise for application in practice.

  8. Iron deficiency among blood donors

    DEFF Research Database (Denmark)

    Rigas, A S; Pedersen, O B; Magnussen, K

    2017-01-01

    Blood components collected from blood donors are an invaluable part of modern-day medicine. A healthy blood donor population is therefore of paramount importance. The results from the Danish Blood Donor Study (DBDS) indicate that gender, number of previous donations, time since last donation...... and menopausal status are the strongest predictors of iron deficiency. Only little information on the health effects of iron deficiency in blood donors exits. Possibly, after a standard full blood donation, a temporarily reduced physical performance for women is observed. However, iron deficiency among blood...... donors is not reflected in a reduced self-perceived mental and physical health. In general, the high proportion of iron-deficient donors can be alleviated either by extending the inter-donation intervals or by guided iron supplementation. The experience from Copenhagen, the Capital Region of Denmark...

  9. Determine The Factors Affecting The Blood Donors Of Selecting Blood Donor Program Me In Western Province Sri Lanka

    Directory of Open Access Journals (Sweden)

    Perera D. A. K.

    2015-08-01

    Full Text Available Abstract Blood and blood component transfusion is one of the major therapeutic practices throughout the world. National Blood Transfusion Service NBTS in Sri Lanka requires approximately 300000 blood units annually. After initiating mobile donor programme there have been two types of blood donation programs in Sri Lanka since 1980. Since second half of first decade of 21st century Sri Lanka shifted to 100 non-replacement blood transfusion policy. That means whole blood and blood component requirement of NBTS has to be collected through mobile blood donor program and voluntary In-house blood donor program. Therefore the objective of this study was to determine the factors affecting the blood donors of selecting blood donor program in Western province Sri Lanka. Methodology This was a cross sectional descriptive study. The study composed of two components. .First the factors that cause the blood donor to select a blood donor programme second the facility survey of blood banks In-house donation. An interviewer administered questionnaire was used to collect data from a sample of 410 Mobile blood donors. Facility survey was done using a checklist. The dependant variables were the attendance of the blood donors to Mobile blood donation and In-house blood donation. Independent variables included were the factors related to socio demography service quality accessibility availability and intrinsic extrinsic motivation. The analytical statistics applied for testing the association of factors with the blood donor programme was chi-square test. The study has shown some important findings. There was significant association between income level and donating blood. Only 3.3 of In-house blood donor population was female. Majority of In-house population belonged to 30-41 age group. A statistically significant association exists between age and repeat blood donation. The female blood donors tendency of becoming repeat donors was very low. Distance problem and non

  10. Radioimmunoassay of serum β2-microglobulin in donor's blood

    International Nuclear Information System (INIS)

    Yin Shihua; Song Shiyun; Li Kelin; Chen Guanglian; Liu Fengmin

    1993-01-01

    Serum β 2 -microglobulin (β 2 -MG) was tested by radioimmunoassay in 149 donors' and 54 healthy volunteers' blood. The results were 203 +- 33.0 nmol/l and 176 +- 26.2 nmol/l, respectively. There was significant difference statistically between them (P 2 -MG content. In order to increase the quality of donated blood and to keep the health of blood donor, it is suggested that the high content of serum β 2 -MG is the indicator of too frequent blood donating. The results also showed that the content of β 2 -MG in donor's blood is not a normal reference value

  11. A Systems Engineering Approach to Quality Assurance for Aerospace Testing

    Science.gov (United States)

    Shepherd, Christena C.

    2015-01-01

    On the surface, it appears that AS91001 has little to say about how to apply a Quality Management System (QMS) to major aerospace test programs (or even smaller ones). It also appears that there is little in the quality engineering Body of Knowledge (BOK)2 that applies to testing, unless it is nondestructive examination (NDE), or some type of lab or bench testing associated with the manufacturing process. However, if one examines: a) how the systems engineering (SE) processes are implemented throughout a test program; and b) how these SE processes can be mapped to the requirements of AS9100, a number of areas for involvement of the quality professional are revealed. What often happens is that quality assurance during a test program is limited to inspections of the test article; what could be considered a manufacturing al fresco approach. This limits the quality professional and is a disservice to the programs and projects, since there are a number of ways that quality can enhance critical processes, and support efforts to improve risk reduction, efficiency and effectiveness.

  12. Donor Hemovigilance Programme in managing Blood Transfusion Needs: Complications of Whole Blood Donation

    Directory of Open Access Journals (Sweden)

    S Mangwana

    2013-10-01

    Full Text Available Background: Hemovigilance like quality systems and audits have become an integral part of Blood Transfusion Services in the developed countries and has contributed greatly to its development. Hemovigilance begins with donors and must enable the collection of information on reactions occurring during the donation of blood, selections of donors and to prevent such incidents. The aim of study was to help identify the trends of adverse events , occurring in blood donors at a tertiary-care hospital, to recommend best practices to improve donor care and safety Materials and Methods: This record-based study was conducted on all adverse events related to allogenic whole blood donations performed over 24 months. All whole blood donations were analyzed. All adverse events occurring during or at the end of the donation were noted using a standardized format and analyzed determining significance at p<0.05. Results: Overall rate was 0.3% with vasovagal reactions constituting 82%, and 18% mild syncopal reactions (p<0.001. Immediate vasovagal reaction with injury was very rare (0.007%. Vasovagal reactions showed a significant association with young age, female gender, first time donation status. Mean age of persons recording adverse effects was 30.23 ± 7.49 years as compared to those without adverse effects, 31.14 ± 8.56 years. Conclusion: Donor safety is an essential perquisite to increase voluntary blood donation. AE analysis helps in identifying the blood donors at risk of AE, applying appropriate motivational strategies, predonation counseling, care during and after donation, developing guidelines and hemovigilance programme in countries with limited resources. DOI: http://dx.doi.org/10.3126/jpn.v3i6.8993   Journal of Pathology of Nepal (2013 Vol. 3, 459-463

  13. Prevalence of glucose-6-phosphate dehydrogenase deficiency and sickle cell trait among blood donors in Riyadh

    Directory of Open Access Journals (Sweden)

    Alabdulaali Mohammed

    2010-01-01

    Full Text Available Background and Aims: Blood donation from glucose-6-phosphate dehydrogenase (G6PD-deficient and sickle cell trait (SCT donors might alter the quality of the donated blood during processing, storage or in the recipient′s circulatory system. The aim of this study was to determine the prevalence of G6PD deficiency and SCT among blood donors coming to King Khalid University Hospital (KKUH in Riyadh. It was also reviewed the benefits and risks of transfusing blood from these blood donors. Materials and Methods: This cross-sectional study was conducted on 1150 blood samples obtained from blood donors that presented to KKUH blood bank during the period April 2006 to May 2006. All samples were tested for Hb-S by solubility test, alkaline gel electrophoresis; and for G6PD deficiency, by fluorescent spot test. Results: Out of the 1150 donors, 23 (2% were diagnosed for SCT, 9 (0.78% for G6PD deficiency and 4 (0.35% for both conditions. Our prevalence of SCT and G6PD deficiency is higher than that of the general population of Riyadh. Conclusion: We recommend to screen all units for G6PD deficiency and sickle cell trait and to defer donations from donors with either of these conditions, unless if needed for special blood group compatibility, platelet apheresis or if these are likely to affect the blood bank inventory. If such blood is to be used, special precautions need to be undertaken to avoid complications in high-risk recipients.

  14. MEASUREMENT OF QUALITY MANAGEMENT SYSTEM PERFORMANCE IN MEAT PROCESSING

    Directory of Open Access Journals (Sweden)

    Elena S. Voloshina

    2017-01-01

    Full Text Available Modern methods aimed to ensure the quality of foods require to implement and certify quality management systems in processing plants. In this case, to measure the effectiveness of existing QMS is often a very difficult task for the leadership due to the fragmentation of the measured metrics, or even lack thereof. This points to the relevance of the conducted research.The criteria for effectiveness assessment of the production process of meat processing plants with the use of scaling methods and Shewhart control charts are presented in the article. The authors developed and presented the formulae for the calculation of single indicators used for the further comprehensive assessment. The algorithm of statistical evaluation of the process controllability, which allows in an accessible form to estimate the statistical control of production processes and to organize statistical quality control in the development of quality management systems, is presented The proposed procedure is based on a process approach, the essence of which is the application of the Deming cycle: “Plan — Do — Check — Act”, which makes it easy to integrate it into any existing quality management system.

  15. [Recommendations for implementing the quality policy and organisation of a quality management system].

    Science.gov (United States)

    Daunizeau, A

    2013-06-01

    Preliminary issues to implement a quality management system are described. They include the definition of the structure, a hierarchical and functional organization chart and the engagement of the whole personnel to apply the requirements of the standard EN ISO 15189. The policy has to be translated into objectives.

  16. Moving up the Ladder: How Do States Deliver Quality Improvement Supports within Their Quality Rating and Improvement Systems? Brief

    Science.gov (United States)

    Holod, Aleksandra; Faria, Ann-Marie; Weinberg, Emily; Howard, Eboni

    2015-01-01

    As national attention has increasingly focused on the potential for high-quality early childhood education (ECE) to improve children's school readiness, states have developed quality rating and improvement systems (QRISs) to document the quality of ECE programs, support systematic quality improvement, and provide clear information to families…

  17. Nuclear information systems: Forming the hub of quality assurance

    International Nuclear Information System (INIS)

    Shepherd, S.H.

    1990-01-01

    Data processing, storage, and transmission technology has advanced sufficiently that nuclear information system networks are developing at many nuclear power plant sites. The networks offer much promise - repetitive tasks can be eliminated, cross checks and reviews can be implemented, and the user can do a more thorough, more professional job. With the arrival of this new power to analyze, plan, communicate, and simplify work comes a duty to properly harness the power. If the power of the information age is misused, or used carelessly, much damage can be done. When it comes to nuclear applications, there are really only three significant features to an information system: quality, reliability, and security. Put simply, the user must trust the accuracy of the system or it cannot be used. A system that is not available for use on demand will not be in demand for long. Fast processors, video graphics, and laser publishing are worthless if one must back up the system with hand calculations and tedious verification of data. An effective nuclear information system has good quality practices interwoven into the hardware and software, so that the system itself can foster and promote better quality assurance

  18. Quality management systems in radiology. Implementation in hospital and radiology practice

    International Nuclear Information System (INIS)

    Teichgraeber, U.; Bucourt, M. de

    2010-01-01

    The concept of quality and the principle of continuous quality improvement are implemented by quality management systems. Quality management systems surpass mere quality control. These systems account for patient and employee needs, the management style and the structure of an enterprise. Many of these quality management systems are used in the health care industry. Some of these systems and their form of application in radiology are introduced here. (orig.)

  19. Cancer Incidence and Mortality in a Cohort of US Blood Donors: A 20-Year Study

    International Nuclear Information System (INIS)

    Vahidnia, F.; Busch, M. P.; Custer, B.; Hirschler, N. V.; Chinn, A.; Agapova, M.; Busch, M. P.; Custer, B.

    2013-01-01

    Blood donors are considered one of the healthiest populations. This study describes the epidemiology of cancer in a cohort of blood donors up to 20 years after blood donation. Records from donors who participated in the Retroviral Epidemiology Donor Study (REDS, 1991-2002) at Blood Centers of the Pacific (BCP), San Francisco, were linked to the California Cancer Registry (CCR, 1991-2010). Standardized incidence ratios (SIR) were estimated using standard US 2000 population, and survival analysis used to compare all-cause mortality among donors and a random sample of non donors with cancer from CCR. Of 55,158 eligible allogeneic blood donors followed-up for 863,902 person-years, 4,236 (7.7%) primary malignant cancers were diagnosed. SIR in donors was 1.59 (95% CI = 1.54,1.64). Donors had significantly lower mortality (adjusted HR = 0.70, 95% CI = 0.66-0.74) compared with non donor cancer patients, except for respiratory system cancers (adjusted HR = 0.93, 95% CI = 0.82-1.05). Elevated cancer incidence among blood donors may reflect higher diagnosis rates due to health seeking behavior and cancer screening in donors. A “healthy donor effect” on mortality following cancer diagnosis was demonstrated. This population-based database and sample repository of blood donors with long-term monitoring of cancer incidence provides the opportunity for future analyses of genetic and other bio markers of cancer

  20. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  1. The restructuring of the quality management system of CDTN

    International Nuclear Information System (INIS)

    Fraga, Rosane Rodrigues; Azevedo, Antonio Mario P.; Haucz, Maria Judith A.; Oliveira, Cezar A.

    2011-01-01

    This article presents the evolution of quality in CDTN, and shows the way chosen to implement and maintain a quality system based on ISO 9001:2008 and ISO/ISO 17025:2005. CDTN is a governmental research institute that develops different activities concerning to nuclear area, like fuel cycle research, radioprotection and radioactive waste management. Beyond these hard core activities, CDTN operates a cyclotron for radiopharmaceuticals production and actuates on the application of nuclear techniques on the industry and environmental studies. Otherwise since ever this nuclear institute works for and with the industries, helping them with researches, analysis and special material assays. Because of the complexity of its activities and the different needs of its units, the quality system has to be structured aiming its efficiency and effectiveness. (author)

  2. The restructuring of the quality management system of CDTN

    Energy Technology Data Exchange (ETDEWEB)

    Fraga, Rosane Rodrigues; Azevedo, Antonio Mario P.; Haucz, Maria Judith A.; Oliveira, Cezar A., E-mail: rosaner@cdtn.br, E-mail: ampa@cdtn.br, E-mail: hauczmj@cdtn.br, E-mail: cao@cdtn.br [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    This article presents the evolution of quality in CDTN, and shows the way chosen to implement and maintain a quality system based on ISO 9001:2008 and ISO/ISO 17025:2005. CDTN is a governmental research institute that develops different activities concerning to nuclear area, like fuel cycle research, radioprotection and radioactive waste management. Beyond these hard core activities, CDTN operates a cyclotron for radiopharmaceuticals production and actuates on the application of nuclear techniques on the industry and environmental studies. Otherwise since ever this nuclear institute works for and with the industries, helping them with researches, analysis and special material assays. Because of the complexity of its activities and the different needs of its units, the quality system has to be structured aiming its efficiency and effectiveness. (author)

  3. Space Station Environmental Health System water quality monitoring

    Science.gov (United States)

    Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

  4. Photovoltaic module quality in the Kenyan solar home systems market

    International Nuclear Information System (INIS)

    Duke, R.D.; Jacobson, A.; Kammen, D.M.

    2002-01-01

    As one of the largest unsubsidized markets for solar home systems (SHSs) in the world, Kenya represents a promising model for rural electrification based on private purchases of clean decentralized photovoltaic technologies. Small amorphous-silicon modules dominate the market and most brands provide high quality and affordable service. Product quality varies widely, however, and the public has limited capacity to distinguish among competing brands. This imposes direct hardships on households with the misfortune to purchase low-quality equipment, and it constrains sales as some customers refrain from purchasing solar equipment due to the associated performance uncertainty. This article analyzes market failure associated with photovoltaic module quality in the Kenyan SHS market and develops strategies to address the problem - emphasizing that similar quality problems may exist for other SHS components and in other markets. The principal conclusion is that domestic product testing with public disclosure represents an inexpensive low-risk strategy, but it may prove inadequate. Mandatory product quality standards based on international testing regimes (e.g. IEC standards), augmented with a basic domestic testing option, would provide stronger assurance, but the risks associated with this intervention suggest caution. An emerging multilateral SHS market support effort (PVMTI) should ensure quality for the credit-based sales it promotes in Kenya; however, the long-term impact of this approach is not yet clear and it is unlikely to address quality problems associated with the unsubsidized sales-based markets for SHSs. Finally, fee-for-service models would decisively address quality problems, but launching this model in the Kenyan market would likely require large subsidies. (author)

  5. Quality assurance of computed and digital radiography systems

    International Nuclear Information System (INIS)

    Walsh, C.; Gorman, D.; Byrne, P.; Larkin, A.; Dowling, A.; Malone, J. F.

    2008-01-01

    Computed radiography (CR) and digital radiography (DR) are replacing traditional film screen radiography as hospitals move towards digital imaging and picture archiving and communication systems (PACS). Both IPEM and KCARE have recently published quality assurance and acceptance testing guidelines for DR. In this paper, the performance of a range of CR and DR systems is compared. Six different manufacturers are included. Particular attention is paid to the performance of the systems under automatic exposure control (AEC). The patient is simulated using a range of thicknesses of tissue equivalent material. Image quality assessment was based on detector assessment protocols and includes pixel value measures as well as subjective assessment using Leeds Test Objects. The protocols for detector assessment cover a broad range of tests and in general detectors (whether DR or CR) performed satisfactorily. The chief limitation in performing these tests was that not all systems provided ready access to pixel values. Subjective tests include the use of the Leeds TO20. As part of this work, suggested reference values are provided to calculate the TO20 image quality factor. One consequence of moving from film screen to digital technologies is that the dynamic range of digital detectors is much wider, and increased exposures are no longer evident from changes in image quality. As such, AEC is a key parameter for CR and DR. Dose was measured using a standard phantom as a basic means of comparing systems. In order to assess the AEC performance, exit doses were also measured while varying phantom thickness. Signal-to-noise ratios (SNRs) were calculated on a number of systems where pixel values were available. SNR was affected by the selection of acquisition protocol. Comparisons between different technologies and collation of data will help refine acceptance thresholds and contribute to optimising dose and image quality. (authors)

  6. Quality assurance and evaluation system in japanese higher education

    Directory of Open Access Journals (Sweden)

    Ana Mami Yamaguchi

    2016-03-01

    Full Text Available Abstract In this paper we aim to contribute to the debate over accountability and assessment of higher education (HE by introducing the Japanese system. We first discuss the circumstances and issues surrounding Japanese HE and then examine the historical development of the quality assurance and evaluation system. Since the 1990s, with the implementation of policies that focused on liberalization, deregulation and increased institutional autonomy, the role of the government has shifted from setting strict regulations and quality standards to organizing an evaluation system for assessing the learning outcomes and improving accountability of the HE institutions. Finally, we suggest how Japan may take hints from Brazil in organizing an evaluation system on a national level that can more efficiently support and assess HE institutions

  7. HACCP system for quality control of food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yiming, Ha [The Institute of Application of Atomic Energy, CAAS, Beijing (China)

    2004-02-01

    This paper introduces the Hazard Analysis and Critical Control Point System (HACCP) and analyses all hazard factors which would possibly affect the product quality in processing of irradiation dehydrated vegetables. It suggests that the irradiation food factories in China should set up HACCP as soon as possible and discusses the ways to set up HACCP.

  8. The role of individual accountability in promoting quality management systems

    NARCIS (Netherlands)

    Turusbekova, N.; Broekhuis, Manda; Emans, B.J.M.; Molleman, E.

    2007-01-01

    Workers sometimes violate, more or less deliberately, Quality Management System ( QMS) procedures and rules, and two of the most essential causes of such violations are the attitude and motivation of the workers. The effectiveness of a QMS may therefore benefit from management tools aimed at

  9. Effect of the Distribution System on Drinking Water Quality

    Directory of Open Access Journals (Sweden)

    A. Grünwald

    2001-01-01

    Full Text Available The overall objective of this paper is to characterise the main aspects of water quality deterioration in a distribution system. The effect of residence time on chlorine uptake and the formation and evolution of disinfection by-products in distributed drinking water are discussed.

  10. HACCP system for quality control of food irradiation

    International Nuclear Information System (INIS)

    Ha Yiming

    2004-01-01

    This paper introduces the Hazard Analysis and Critical Control Point System (HACCP) and analyses all hazard factors which would possibly affect the product quality in processing of irradiation dehydrated vegetables. It suggests that the irradiation food factories in China should set up HACCP as soon as possible and discusses the ways to set up HACCP

  11. Application of Total Quality Management System in Thai Primary Schools

    Science.gov (United States)

    Prueangphitchayathon, Setthiya; Tesaputa, Kowat; Somprach, Kanokorn

    2015-01-01

    The present study seeks to develop a total quality management (TQM) system that can be applied to primary schools. The approach focuses on customer orientation, total involvement of all constituencies and continuous improvement. TQM principles were studied and synthesized according to case studies of the best practices in 3 primary schools (small,…

  12. Impact of Quality Management Systems on Teaching-Learning Processes

    Science.gov (United States)

    Cruz, Francisco José Fernández; Gálvez, Inmaculada Egido; Santaolalla, Rafael Carballo

    2016-01-01

    Purpose: Quality management systems are being used more frequently in educational institutions, although their application has generated a certain amount of disagreement among education experts, who have at times questioned their suitability and usefulness for improving schools. The purpose of this paper is to contribute to this discussion by…

  13. Evaluating Frequency Quality of Nordic System using PMU data

    DEFF Research Database (Denmark)

    Xu, Zhao; Østergaard, Jacob; Togeby, Mikael

    2008-01-01

    This paper focuses on analysing frequency quality of Nordic power system using measurements from Phasor Measurement Units (PMU). The PMU data of one year long period is used which has very high time resolution (20 ms per sample) and is able to provide detailed information in evaluating frequency...

  14. Quality electricity lines of external power systems electric traction DC

    Directory of Open Access Journals (Sweden)

    A.V. Petrov

    2012-08-01

    Full Text Available The results of studies that compare and analyze the numerical values of some key indicators quality electricity in the lines of the external power supply system the electric traction DC. As a supplement are additional and fundamental values of energy losses in them.

  15. Determinants of quality management systems implementation in hospitals

    NARCIS (Netherlands)

    Wardhani, Viera; Utarini, Adi; van Dijk, Jitse Pieter; Post, Doeke; Groothoff, Johan Willem

    Objective: To identify the problems and facilitating factors in the implementation of quality management system (QMS) in hospitals through a systematic review. Method: A search strategy was pet-formed on the Medline database for articles written in English published between 1992 and early 2006.

  16. Support for Quality Assurance in End-User Systems.

    Science.gov (United States)

    Klepper, Robert; McKenna, Edward G.

    1989-01-01

    Suggests an approach that organizations can take to provide centralized support services for quality assurance in end-user information systems, based on the experiences of a support group at Citicorp Mortgage, Inc. The functions of the support group include user education, software selection, and assistance in testing, implementation, and support…

  17. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  18. Quality assurance system for sitting high risk facilities

    International Nuclear Information System (INIS)

    Rodriguez, Aymee; Peralta, Jose L.; Fernandez, Manuel

    1999-01-01

    The paper shows how we have conceived and designed the quality assurance system for the site selection process of an area for sitting the facility of high risk in correspondence with the approved methodology. The results obtained in the implementation of the system have permitted the satisfactory performance of each one the expected stage, defining the most favorable sectors in order to continue the studies of the repository site for the disposal of low and intermedium. (author)

  19. An inspection demonstration program/a quality system

    International Nuclear Information System (INIS)

    Cox, L.D.

    1995-01-01

    Mobil relies on tubular manufacturers to consistently supply OCTG which complies with all material requirements of API Specification 5CT. This paper details the Mobil Inspection Demonstration Program; Mobil's method for qualifying ultrasonic inspection systems for use during Mobil receiving inspections. Additionally, the basic fundamentals of the Mobil quality system and acceptance sampling are presented with an emphasis on tracking short-term and long-term supplier performance

  20. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Franco E, J.G. [UAM-Xochimilco, 04960 Mexico D.F. (Mexico); Azorin N, J. [UAM-Iztapalapa, 09340 Mexico D.F. (Mexico); Diaz G, J.A.I. [CICATA, Unidad Legaria, Av. Legaria 694, 11599 mexico D.F. (Mexico); Arreola, M. [Department of Radiology, Shands Hospital at UF, PO Box 100374, Gainesville, FL 32610-0374 (United States)

    2006-07-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  1. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2006-01-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  2. Determinants of quality management systems implementation in hospitals.

    Science.gov (United States)

    Wardhani, Viera; Utarini, Adi; van Dijk, Jitse Pieter; Post, Doeke; Groothoff, Johan Willem

    2009-03-01

    To identify the problems and facilitating factors in the implementation of quality management system (QMS) in hospitals through a systematic review. A search strategy was performed on the Medline database for articles written in English published between 1992 and early 2006. Using the thesaurus terms 'Total Quality Management' and 'Quality Assurance Health Care', combined with the term 'hospital' and 'implement*', we identified 533 publications. The screening process was based on empirical articles describing organization-wide QMS implementation. Fourteen empirical articles fulfilled the inclusion criteria and were reviewed in this paper. An organization culture emphasizing standards and values associated with affiliation, teamwork and innovation, assumption of change and risk taking, play as the key success factor in QMS implementation. This culture needs to be supported by sufficient technical competence to apply a scientific problem-solving approach. A clear distribution of QMS function within the organizational structure is more important than establishing a formal quality structure. In addition to management leadership, physician involvement also plays an important role in implementing QMS. Six supporting and limiting factors determining QMS implementation are identified in this review. These are the organization culture, design, leadership for quality, physician involvement, quality structure and technical competence.

  3. Towards a Fuzzy Expert System on Toxicological Data Quality Assessment.

    Science.gov (United States)

    Yang, Longzhi; Neagu, Daniel; Cronin, Mark T D; Hewitt, Mark; Enoch, Steven J; Madden, Judith C; Przybylak, Katarzyna

    2013-01-01

    Quality assessment (QA) requires high levels of domain-specific experience and knowledge. QA tasks for toxicological data are usually performed by human experts manually, although a number of quality evaluation schemes have been proposed in the literature. For instance, the most widely utilised Klimisch scheme1 defines four data quality categories in order to tag data instances with respect to their qualities; ToxRTool2 is an extension of the Klimisch approach aiming to increase the transparency and harmonisation of the approach. Note that the processes of QA in many other areas have been automatised by employing expert systems. Briefly, an expert system is a computer program that uses a knowledge base built upon human expertise, and an inference engine that mimics the reasoning processes of human experts to infer new statements from incoming data. In particular, expert systems have been extended to deal with the uncertainty of information by representing uncertain information (such as linguistic terms) as fuzzy sets under the framework of fuzzy set theory and performing inferences upon fuzzy sets according to fuzzy arithmetic. This paper presents an experimental fuzzy expert system for toxicological data QA which is developed on the basis of the Klimisch approach and the ToxRTool in an effort to illustrate the power of expert systems to toxicologists, and to examine if fuzzy expert systems are a viable solution for QA of toxicological data. Such direction still faces great difficulties due to the well-known common challenge of toxicological data QA that "five toxicologists may have six opinions". In the meantime, this challenge may offer an opportunity for expert systems because the construction and refinement of the knowledge base could be a converging process of different opinions which is of significant importance for regulatory policy making under the regulation of REACH, though a consensus may never be reached. Also, in order to facilitate the implementation

  4. Analysis of the quality of hospital information systems Audit Trails.

    Science.gov (United States)

    Cruz-Correia, Ricardo; Boldt, Isabel; Lapão, Luís; Santos-Pereira, Cátia; Rodrigues, Pedro Pereira; Ferreira, Ana Margarida; Freitas, Alberto

    2013-08-06

    Audit Trails (AT) are fundamental to information security in order to guarantee access traceability but can also be used to improve Health information System's (HIS) quality namely to assess how they are used or misused. This paper aims at analysing the existence and quality of AT, describing scenarios in hospitals and making some recommendations to improve the quality of information. The responsibles of HIS for eight Portuguese hospitals were contacted in order to arrange an interview about the importance of AT and to collect audit trail data from their HIS. Five institutions agreed to participate in this study; four of them accepted to be interviewed, and four sent AT data. The interviews were performed in 2011 and audit trail data sent in 2011 and 2012. Each AT was evaluated and compared in relation to data quality standards, namely for completeness, comprehensibility, traceability among others. Only one of the AT had enough information for us to apply a consistency evaluation by modelling user behaviour. The interviewees in these hospitals only knew a few AT (average of 1 AT per hospital in an estimate of 21 existing HIS), although they all recognize some advantages of analysing AT. Four hospitals sent a total of 7 AT - 2 from Radiology Information System (RIS), 2 from Picture Archiving and Communication System (PACS), 3 from Patient Records. Three of the AT were understandable and three of the AT were complete. The AT from the patient records are better structured and more complete than the RIS/PACS. Existing AT do not have enough quality to guarantee traceability or be used in HIS improvement. Its quality reflects the importance given to them by the CIO of healthcare institutions. Existing standards (e.g. ASTM:E2147, ISO/TS 18308:2004, ISO/IEC 27001:2006) are still not broadly used in Portugal.

  5. South Korea as an emerging donor

    DEFF Research Database (Denmark)

    Chun, Hong-Min; Munyi, Elijah Nyaga; Lee, Heejin

    2010-01-01

    South Korea's official development assistance (ODA) has been increasing rapidly and will continue to do so. Korea is one of the few countries which have successfully transitioned from a recipient to a donor. It became a member of DAC (development assistance committee), OECD in November 2009. Korea......'s ODA policy, along with its growth in quantity, is at a crossroads for the enhancement of its quality. Discussions and debates are going on regarding the reforms in Korea's ODA activities, and this paper examines key issues raised. It first reviews the past and present of Korea's ODA, and identifies...... like the objective of ODA, positioning of Korea's ODA as an emerging donor and the nature of aid to North Korea. We also argue that a shift of ODA policy is required to promote reform, based on a thorough reflection on the role of ODA in the alleviation of poverty and promoting sustainable development...

  6. Development of a quality management system for borehole investigations. (1) Quality assurance and quality control methodology for hydraulic packer testing

    International Nuclear Information System (INIS)

    Takeuchi, Shinji; Kunimaru, Takanori; Ota, Kunio; Frieg, Bernd

    2011-01-01

    A quality assurance and quality control (QA/QC) system for the hydraulic packer tests has been established based on the surface-based investigations at JAEA's underground research laboratories in Mizunami and Horonobe. The established QA/QC system covers field investigations (data acquisition) and data analysis. For the field investigations, the adopted procedure is selection of a test section based on a detail fluid logging and checking with tally list, followed by inspection of test tools such as pressure transducers and shut-in valves, etc., test method selection using a 'sequential hydraulic test' for deciding appropriate method, and finally data quality confirmation by pressure changes and derivatives on a log-log plots during testing. Test event logs should also be described during testing for traceability. For the test data analysis, a quick analysis for rough estimation of hydraulic parameters, and a detailed analysis using type curve and/or numerical analyses are conducted stepwise. The established QA/QC system has been applied to the recent borehole investigations and its efficiency has been confirmed. (author)

  7. SSCL magnet systems quality program implementation for laboratory and industry

    International Nuclear Information System (INIS)

    Warner, D.G.; Bever, D.L.

    1992-01-01

    The development and delivery of reliable and producible magnets for the Superconducting Super Collider Laboratory (SSCL) require the teamwork of a large and diverse workforce composed of personnel with backgrounds in laboratory research, defense, and energy. The SSCL Magnet Quality Program is being implemented with focus on three definitive objectives: (1) communication of requirements, (2) teamwork, and (3) verification. Examination of the SSCL Magnet Systems Division's (MSD) current and planned approach to implementation of the SSCL Magnet Quality Program utilizing these objectives is discussed

  8. Microscreen effects on water quality in replicated recirculating aquaculture systems

    DEFF Research Database (Denmark)

    Fernandes, Paulo; Pedersen, Lars-Flemming; Pedersen, Per Bovbjerg

    2015-01-01

    This study investigated the effects of three microscreen mesh sizes (100, 60 and 20 μm) on water quality and rainbow trout (Oncorhynchus mykiss) performance compared to a control group without microscreens, in triplicated recirculating aquaculture systems (RAS). Operational conditions were kept....... Fish performed similarly in all treatments. Preliminary screening of trout gills did not reveal any pathological changes related to microscreen filtration and the resulting water quality. Biofilter performance was also unaffected, with 0′-order nitrification rates (k0a) being equivalent for all twelve...

  9. Office of Storage and Transportation Systems quality assurance directive

    International Nuclear Information System (INIS)

    1986-10-01

    This Directive provides policy guidance, defines organizational authorities and responsibilities for quality assurance (QA) and establishes minimum acceptable requirements for assuring the quality of all programs under the overall direction of the OSTS. This directive provides guidance for preparation of subordinate QA documents (e.g., QA plans, procedures) for the major Office of Storage and Transportation Systems programs that support DOE licensing and/or certification objectives. In turn, those highly specific QA documents will amplify the general guidance presented in this Directive

  10. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  11. Quality functions for requirements engineering in system development methods.

    Science.gov (United States)

    Johansson, M; Timpka, T

    1996-01-01

    Based on a grounded theory framework, this paper analyses the quality characteristics for methods to be used for requirements engineering in the development of medical decision support systems (MDSS). The results from a Quality Function Deployment (QFD) used to rank functions connected to user value and a focus group study were presented to a validation focus group. The focus group studies take advantage of a group process to collect data for further analyses. The results describe factors considered by the participants as important in the development of methods for requirements engineering in health care. Based on the findings, the content which, according to the user a MDSS method should support is established.

  12. Donor selection criteria and procurement

    International Nuclear Information System (INIS)

    Agcaoili, N.R.

    1999-01-01

    Donor selection is one of the most important aspects of tissue banking practice. Without a good donor selection criteria, the results of any effort of trying to preserve tissues will have disastrous outcome for the recipient of these tissues. While with a very good and strict donor selection the Tissue Bank can guarantee safe and effective tissue allografts. There are significant aspects in the history and physical examination of the donor that must be emphasized. A donor exclusion criteria has also been formulated together with a list of all the needed laboratory examinations to eliminate possible diseases that may be transferred from the donor. The methods of procurement of tissue allografts from living and cadaver donors will be described. The limitations and advantages of each will be taken.There are also special restrictions that are important in the practice of removing the tissues from the donors. All the necessary equipment should be ready and the potential risk on the personnel should be known to all doing Tissue Banking

  13. The Dirt on the Donors.

    Science.gov (United States)

    Walker, Mary Margaret

    1996-01-01

    A discussion of donor records in college and university fund-raising programs looks at a variety of issues, including who sees them (administrators, donors, volunteers, and members of the legal profession), how access to them is controlled, and what is kept in them. Suggestions are offered for managing such records, and the experiences of a number…

  14. Systems Engineering Metrics: Organizational Complexity and Product Quality Modeling

    Science.gov (United States)

    Mog, Robert A.

    1997-01-01

    Innovative organizational complexity and product quality models applicable to performance metrics for NASA-MSFC's Systems Analysis and Integration Laboratory (SAIL) missions and objectives are presented. An intensive research effort focuses on the synergistic combination of stochastic process modeling, nodal and spatial decomposition techniques, organizational and computational complexity, systems science and metrics, chaos, and proprietary statistical tools for accelerated risk assessment. This is followed by the development of a preliminary model, which is uniquely applicable and robust for quantitative purposes. Exercise of the preliminary model using a generic system hierarchy and the AXAF-I architectural hierarchy is provided. The Kendall test for positive dependence provides an initial verification and validation of the model. Finally, the research and development of the innovation is revisited, prior to peer review. This research and development effort results in near-term, measurable SAIL organizational and product quality methodologies, enhanced organizational risk assessment and evolutionary modeling results, and 91 improved statistical quantification of SAIL productivity interests.

  15. Quality control of MC and A system and integrated safeguards

    International Nuclear Information System (INIS)

    Osabe, Takeshi

    2000-01-01

    In the integrated safeguards regime, co-operation with SSAC is a vital element to achieve efficiency of safeguards implementation while maintaining the effectiveness. However, the degree of co-operation fully depends upon the credibility, technical capability and the transparency of SSAC. Since the credibility of SSAC (States' System of Accounting for and Control of Nuclear Materials) depends heavily on effectiveness of facility operator's Material Control and Accounting (MC and A) practice, some measures to provide continuous assurance of the function and effectiveness of the system such as quality assurance program including periodical system audit (diagnostic) function ought to be established. This paper discusses quality assurance program for facility level MC and A including audit (diagnostic) method to maintain continuous assurance of the effectiveness. (author)

  16. Quality indicators in a computerized technology information system

    International Nuclear Information System (INIS)

    Mancuso, C.A.; Hyde, R.A.

    1992-01-01

    An environmental technology information system was developed by EG ampersand G Idaho, Inc. at the Idaho National Engineering Laboratory (INEL) for the Department of Energy (DOE). The purpose of the system is to reduce costs and time associated with evaluating potential remedial alternatives for a waste site. The information system is organized to aid in the CERCLA process by describing the implementability, effectiveness, and cost of many remedial technologies. Technology categories included in the information system include: Institutional Controls, Retrieval, Separation, Characterization, Physical/Chemical Treatment, Biological Treatment, Thermal Treatment, Storage, Transportation, Disposal, Migration Control (containment), Support Systems, Waste Minimization, and Remote Operations. Two hundred and sixty processes are summarized in these technology areas. Information on these processes was collected from EPA publications, books, journal articles, conference proceedings, vendors, DOE publications, and technical experts. The purpose of this paper is to familiarize readers with issues associated with the development of information systems. A major issue is the system and software quality, which can be controlled by configuration management. Another major issue is the documentation of data quality indicators in references used to collect data for the system, which can not be controlled but must be planned for in the review process

  17. Socio-demographic characteristics of Danish blood donors

    DEFF Research Database (Denmark)

    Burgdorf, Kristoffer Sølvsten; Simonsen, Jacob; Sundby, Anna

    2017-01-01

    Background: Blood transfusion is an essential component of a modern healthcare system. Because knowledge about blood donor demography may inform the design of strategies for donor recruitment and retention, we used nationwide registers to characterize the entire population of blood donors...... in 2010. The association between sociodemographic characteristics and blood donor prevalence was examined using regression models. Results: The overall prevalence of blood donation was 5.4% among both women and men. The age-specific prevalence of blood donation peaked at 25 years of age (6.8%) for women...... and 30 years of age (5.7%) for men. Children of any age were associated with lower prevalence of blood donation among women, while the opposite was seen for men. Middle to high income groups, but not the highest income group, had fourfold higher donor prevalence than the lowest income group (6...

  18. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  19. Merging Air Quality and Public Health Decision Support Systems

    Science.gov (United States)

    Hudspeth, W. B.; Bales, C. L.

    2003-12-01

    The New Mexico Air Quality Mapper (NMAQM) is a Web-based, open source GIS prototype application that Earth Data Analysis Center is developing under a NASA Cooperative Agreement. NMAQM enhances and extends existing data and imagery delivery systems with an existing Public Health system called the Rapid Syndrome Validation Project (RSVP). RSVP is a decision support system operating in several medical and public health arenas. It is evolving to ingest remote sensing data as input to provide early warning of human health threats, especially those related to anthropogenic atmospheric pollutants and airborne pathogens. The NMAQM project applies measurements of these atmospheric pollutants, derived from both remotely sensed data as well as from in-situ air quality networks, to both forecasting and retrospective analyses that influence human respiratory health. NMAQM provides a user-friendly interface for visualizing and interpreting environmentally-linked epidemiological phenomena. The results, and the systems made to provide the information, will be applicable not only to decision-makers in the public health realm, but also to air quality organizations, demographers, community planners, and other professionals in information technology, and social and engineering sciences. As an accessible and interactive mapping and analysis application, it allows environment and health personnel to study historic data for hypothesis generation and trend analysis, and then, potentially, to predict air quality conditions from daily data acquisitions. Additional spin off benefits to such users include the identification of gaps in the distribution of in-situ monitoring stations, the dissemination of air quality data to the public, and the discrimination of local vs. more regional sources of air pollutants that may bear on decisions relating to public health and public policy.

  20. Quality and safety implications of emergency department information systems.

    Science.gov (United States)

    Farley, Heather L; Baumlin, Kevin M; Hamedani, Azita G; Cheung, Dickson S; Edwards, Michael R; Fuller, Drew C; Genes, Nicholas; Griffey, Richard T; Kelly, John J; McClay, James C; Nielson, Jeff; Phelan, Michael P; Shapiro, Jason S; Stone-Griffith, Suzanne; Pines, Jesse M

    2013-10-01

    The Health Information Technology for Economic and Clinical Health Act of 2009 and the Centers for Medicare & Medicaid Services "meaningful use" incentive programs, in tandem with the boundless additional requirements for detailed reporting of quality metrics, have galvanized hospital efforts to implement hospital-based electronic health records. As such, emergency department information systems (EDISs) are an important and unique component of most hospitals' electronic health records. System functionality varies greatly and affects physician decisionmaking, clinician workflow, communication, and, ultimately, the overall quality of care and patient safety. This article is a joint effort by members of the Quality Improvement and Patient Safety Section and the Informatics Section of the American College of Emergency Physicians. The aim of this effort is to examine the benefits and potential threats to quality and patient safety that could result from the choice of a particular EDIS, its implementation and optimization, and the hospital's or physician group's approach to continuous improvement of the EDIS. Specifically, we explored the following areas of potential EDIS safety concerns: communication failure, wrong order-wrong patient errors, poor data display, and alert fatigue. Case studies are presented that illustrate the potential harm that could befall patients from an inferior EDIS product or suboptimal execution of such a product in the clinical environment. The authors have developed 7 recommendations to improve patient safety with respect to the deployment of EDISs. These include ensuring that emergency providers actively participate in selection of the EDIS product, in the design of processes related to EDIS implementation and optimization, and in the monitoring of the system's ongoing success or failure. Our recommendations apply to emergency departments using any type of EDIS: custom-developed systems, best-of-breed vendor systems, or enterprise systems

  1. TL dosimetry for quality control of CR mammography imaging systems

    Science.gov (United States)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  2. Heart transplantation from older donors

    Directory of Open Access Journals (Sweden)

    V. N. Poptsov

    2017-01-01

    Full Text Available In the current situation of the shortage of suitable donor organs, heart transplantation from older donors is one of the ways to increase the performance of more heart transplants, particularly, in patients with urgent need of transplantation. While planning a heart transplantation from older donor one should consider increased risk of early cardiac allograft dysfunction, preexisting coronary artery disease, accelerated transplant vasculopathy which may adversely affect early and long-term survival of recipients. Subject to careful selection of donor–recipient pairs, effective prevention and treatment of early cardiac allograft dysfunction, pre-existing atherosclerosis and transplant vasculopathy the early and long-term survival of heart transplant recipients from older donors is comparable to heart transplantation from young donors.

  3. Information security system quality assessment through the intelligent tools

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    The technology development has shown the automated system information security comprehensive analysis necessity. The subject area analysis indicates the study relevance. The research objective is to develop the information security system quality assessment methodology based on the intelligent tools. The basis of the methodology is the information security assessment model in the information system through the neural network. The paper presents the security assessment model, its algorithm. The methodology practical implementation results in the form of the software flow diagram are represented. The practical significance of the model being developed is noted in conclusions.

  4. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; Shappert, L.B.

    1992-01-01

    This paper discusses applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 which are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  5. Banking system reform, earnings quality and credit allocation

    Institute of Scientific and Technical Information of China (English)

    Xiuli Zhu; Lianjun Li; Yunkui Xue

    2012-01-01

    This paper investigates credit allocation before and after the 2003 banking system reform in China. We find that relationships between earnings quality and new short-term loans, long-term loans and total loans in listed companies changed significantly after the banking system reform, especially in stateowned listed companies. Further investigation shows that due to the influence of rent-seeking, banks have eased the earnings requirements of non-stateowned listed companies. These findings enhance our understanding of the economic consequences of the banking system reform and of credit discrimination under the new regime.

  6. Banking system reform, earnings quality and credit allocation

    Directory of Open Access Journals (Sweden)

    Xiuli Zhu

    2012-09-01

    Full Text Available This paper investigates credit allocation before and after the 2003 banking system reform in China. We find that relationships between earnings quality and new short-term loans, long-term loans and total loans in listed companies changed significantly after the banking system reform, especially in state-owned listed companies. Further investigation shows that due to the influence of rent-seeking, banks have eased the earnings requirements of non-state-owned listed companies. These findings enhance our understanding of the economic consequences of the banking system reform and of credit discrimination under the new regime.

  7. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; McCreery, P.N.; Shappert, L.B.

    1991-01-01

    Applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  8. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  9. Optimal screening and donor management in a public stool bank.

    Science.gov (United States)

    Kazerouni, Abbas; Burgess, James; Burns, Laura J; Wein, Lawrence M

    2015-12-17

    Fecal microbiota transplantation is an effective treatment for recurrent Clostridium difficile infection and is being investigated as a treatment for other microbiota-associated diseases. To facilitate these activities, an international public stool bank has been created, which screens donors and processes stools in a standardized manner. The goal of this research is to use mathematical modeling and analysis to optimize screening and donor management at the stool bank. Compared to the current policy of screening active donors every 60 days before releasing their quarantined stools for sale, costs can be reduced by 10.3 % by increasing the screening frequency to every 36 days. In addition, the stool production rate varies widely across donors, and using donor-specific screening, where higher producers are screened more frequently, also reduces costs, as does introducing an interim (i.e., between consecutive regular tests) stool test for just rotavirus and C. difficile. We also derive a donor release (i.e., into the system) policy that allows the supply to approximately match an exponentially increasing deterministic demand. More frequent screening, interim screening for rotavirus and C. difficile, and donor-specific screening, where higher stool producers are screened more frequently, are all cost-reducing measures. If screening costs decrease in the future (e.g., as a result of bringing screening in house), a bottleneck for implementing some of these recommendations may be the reluctance of donors to undergo serum screening more frequently than monthly.

  10. Donor conversion and procurement failure: the fate of our potential organ donors.

    Science.gov (United States)

    Branco, Bernardino C; Inaba, Kenji; Lam, Lydia; Salim, Ali; Barmparas, Galinos; Teixeira, Pedro G R; Talving, Peep; Demetriades, Demetrios

    2011-02-01

    Donor availability remains the primary limiting factor for organ transplantation today. The purpose of this study was to examine the causes of procurement failure amongst potential organ donors. After Institutional Review Board approval, all surgical intensive care unit (SICU) patients admitted to the LAC+USC Medical Center from 01/2006 to 12/2008 who became potential organ donors were identified. Demographics, clinical data, and procurement data were abstracted. In non-donors, the causes of procurement failure were documented. During the 3-year study period, a total of 254 patients were evaluated for organ donation. Mean age was 44.8±18.7 years; 191 (75.2%) were male, 136 (53.5%) were Hispanic, and 148 (58.3%) were trauma patients. Of the 254 patients, 116 (45.7%) were not eligible for donation: 34 had multi-system organ failure, 24 did not progress to brain death and had support withdrawn, 18 had uncontrolled sepsis, 15 had malignancy, 6 had human immunodeficiency virus or hepatitis B or C, and 19 patients had other contraindications to organ donation. Of the remaining 138 eligible patients, 83 (60.2%) did not donate: 56 because the family denied consent, 9 by their own choice. In six, next of kin could not be located, five died because of hemodynamic instability before organ procurement was possible, four had organs that could not be placed, and three had their organs declined by the organ procurement organization. The overall consent rate was 57.5% (n=67). From the 55 donors, 255 organs were procured (yield 4.6 organs/donor). Of all patients screened for organ donation, only a fifth actually donated. Denial of consent was the major potentially preventable cause of procurement failure, whereas hemodynamic instability accounted for only a small percentage of donor losses. With such low conversion rates, the preventable causes of procurement failure warrant further study.

  11. Expert System for Quality Assessment in "Tibiscus" University

    Directory of Open Access Journals (Sweden)

    Catalin Tuican

    2008-01-01

    Full Text Available The periodical evaluation of the teaching staff in „Tibiscus” University bases on the specifications of The Romanian Agency for Quality Assurance in Higher Education (Agenţia Română de Asigurare a Calităţii în Învăţământul Superior, ARACIS namely : „The quality of the teaching and researching staff The universities must dispose of teaching staff which, as number and functional base, must be correctly allocated to the total number of students, depending on the study domain, and regarding the qualifications it must depend on the specific of the study program and the proposed quality objectives.” This paper presents the implementation of an expert system, offering to the students the possibility to perform the evaluation in a modern way and to the evaluation committee a quick access to all necessary data.

  12. Dosimetry and image quality assessment in a direct radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Paixao, Lucas; Nogueira, Maria do Socorro, E-mail: boliveira.mg@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Oliveira, Marcio Alves de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Anatomia e Imagem; Teixeira, Maria Helena Araujo [Clinica Dra. Maria Helena Araujo Teixeira, Belo Horizonte, MG (Brazil)

    2014-11-15

    Objective: to evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and methods: Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results: considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion: the present study contributes to verify the equipment conformity as regards dose values and image quality. (author)

  13. Recommendations for use of marginal donors in heart transplantation: Brazilian Association of Organs Transplantation guideline.

    Science.gov (United States)

    Fiorelli, A I; Stolf, N A G; Pego-Fernandes, P M; Oliveira Junior, J L; Santos, R H B; Contreras, C A M; Filho, D D L; Dinkhuysen, J J; Moreira, M C V; Mejia, J A C; Castro, M C R

    2011-01-01

    The high prevalence of heart failure has increased the candidate list for heart transplantation; however, there is a shortage of viable donated organs, which is responsible for the high mortality of patients awaiting a transplantation. Because the marginal donor presents additional risk factors, it is not considered to be an ideal donor. The use of a marginal donor is only justified in situations when the risk of patient death due to heart disease is greater than that offered by the donor. These recommendations sought to expand the supply of donors, consequently increasing the transplant rate. We selected articles based on robust evidence to provide a substratum to develop recommendations for donors who exceed the traditional acceptance criteria. Recipient survival in the immediate postoperative period is intimately linked to allograft quality. Primary allograft failure is responsible for 38% to 40% of immediate deaths after heart transplantation: therefore; marginal donor selection must be more rigorous to not increase the surgical risk. The main donor risk factors with the respective evidence levels are: cancer in the donor (B), female donor (B), donor death due to hemorrhagic stroke (B), donor age above 50 years (relative risk [RR] = 1.5) (B), weight mismatch between donor and recipient 240 minutes (RR = 1.2) (B), left ventricular dysfunction with ejection fraction below 45% (B), and use of high doses of vasoactive drugs (dopamine > 15 mg/kg·min) (B). Factors that impact recipient mortality are: age over 50 years (RR = 1.5); allograft harvest at a distance; adult recipient weighing more than 20% of the donor; high doses of vasoactive drugs (dopamine greater than 15 mg/kg·min) and ischemic time >4 hours. The use of a marginal donor is only justified when it is able to increase life expectancy compared with clinical treatment, albeit the outcomes are interior to those using an ideal donor. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. AQUIS: An air quality and permit information management system

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A.E.; Huber, C.C.; Tschanz, J. (Argonne National Lab., IL (USA)); Ryckman, S.J. Jr. (Air Force Logistics Command, Wright-Patterson AFB, OH (USA))

    1991-01-01

    The Air Quality Utility Information System (AQUIS) is a data base management system that operates on a dedicated, IBM-compatible personal computer using dBASE IV. AQUIS is in operation at six of the seven US Air Force Logistics Command (AFLC) bases to assist with the management of the source inventory, permit tracking, and the estimating and tracking of emissions. The system also provides environmental management personnel with information on regulatory requirements and other compliance information. An AFLC base can have over 500 regulated or unregulated emission sources, and the task of tracking and correlating emissions, sources, and permits is substantial. AQUIS is a comprehensive management tool that provides a single system for storing and accessing information previously available only in multiple, uncorrelated files. This paper discusses the development of the system and provides an overview of the system structure and the relationship of that structure to sources in the field. Certain features such as the linking capability and compound-specific emissions are highlighted. The experience of environmental managers, the ultimate system users, is discussed, including specific ways in which AQUIS has proven useful in responding to managers' needs for air quality information. 10 refs., 3 figs., 1 tab.

  15. Operating multireservoir hydropower systems for downstream water quality

    International Nuclear Information System (INIS)

    Hayes, D.F.

    1990-01-01

    Hydropower reservoir operations often impact tailwater quality and water quality in the stream or river below the impoundment for many miles. Determining optimal operating strategies for a system of hydropower reservoirs involves solving a highly dimensional nonlinear, nonconvex optimization problem. This research adds the additional complexities of downstream water quality considerations within the optimization formulation to determine operating strategies for a system of hydropower reservoirs operating in series (tandem) or parallel. The formulation was used to determine operating strategies for six reservoirs of the upper Cumberland river basin in Tennessee and Kentucky. Significant dissolved oxygen (DO) violations occur just upstream of Nashville, Tennessee below Old Hickory dam during the months of August and September. Daily reservoir releases were determined for the period of June through September which would produce the maximum hydropower revenue while meeting downstream water quality objectives. Optimal releases for three operational strategies were compared to historical operations for the years 1985, 1986, and 1988. These strategies included: spilling as necessary to meet water quality criteria, near normal operation (minimal spills), and drawdown of reservoirs as necessary to meet criteria without spills. Optimization results showed an 8% to 15% hydropower loss may be necessary to meet water quality criteria through spills and a 2% to 9% improvement in DO below Old Hickory may be possible without significant spills. Results also showed that substantial increases in initial headwater elevations would be necessary to meet daily DO criteria and avoid spills. The optimal control theory algorithm used to solve the problem proved to be an efficient and robust solver of this large optimization problem

  16. [Development of quality assurance/quality control web system in radiotherapy].

    Science.gov (United States)

    Okamoto, Hiroyuki; Mochizuki, Toshihiko; Yokoyama, Kazutoshi; Wakita, Akihisa; Nakamura, Satoshi; Ueki, Heihachi; Shiozawa, Keiko; Sasaki, Koji; Fuse, Masashi; Abe, Yoshihisa; Itami, Jun

    2013-12-01

    Our purpose is to develop a QA/QC (quality assurance/quality control) web system using a server-side script language such as HTML (HyperText Markup Language) and PHP (Hypertext Preprocessor), which can be useful as a tool to share information about QA/QC in radiotherapy. The system proposed in this study can be easily built in one's own institute, because HTML can be easily handled. There are two desired functions in a QA/QC web system: (i) To review the results of QA/QC for a radiotherapy machine, manuals, and reports necessary for routinely performing radiotherapy through this system. By disclosing the results, transparency can be maintained, (ii) To reveal a protocol for QA/QC in one's own institute using pictures and movies relating to QA/QC for simplicity's sake, which can also be used as an educational tool for junior radiation technologists and medical physicists. By using this system, not only administrators, but also all staff involved in radiotherapy, can obtain information about the conditions and accuracy of treatment machines through the QA/QC web system.

  17. Practical evaluation of clinical image quality (4). Determination of image quality in digital radiography system

    International Nuclear Information System (INIS)

    Katayama, Reiji

    2016-01-01

    Recently, for medical imaging, digital radiography systems are widely used in clinical practices. However, a study in the past reported that a patient radiation exposure level by digital radiography is in fact not lower than that by analog radiography system. High level of attention needs to be paid for over-exposure when using the conventional analog radiography with a screen and a film, as it results in high density of the film. However, for digital radiography systems, since the automatic adjusting function of image density is equipped with them, no attention for radiation dose need to be paid. Thus technologists tend to be careless and results in higher chance for over-exposure. Current digital radiography systems are high-performance in the image properties and capable of patient dose reduction. Especially, the image quality of the flat panel detector system is recognized, higher than that of the computed radiography system by imaging plates, in both objective and subjective evaluations. Therefore, we technologists are responsible for optimizing the balance between the image quality of the digital radiogram and the radiation dose required for each case. Moreover, it is also required for us as medical technologists to make effective use of such evaluation result of medical images for patients. (author)

  18. Interaction of feel system and flight control system dynamics on lateral flying qualities

    Science.gov (United States)

    Bailey, R. E.; Knotts, L. H.

    1990-01-01

    An experimental investigation of the influence of lateral feel system characteristics on fighter aircraft roll flying qualities was conducted using the variable stability USAF NT-33. Forty-two evaluation flights were flown by three engineering test pilots. The investigation utilized the power approach, visual landing task and up-and-away tasks including formation, gun tracking, and computer-generated compensatory attitude tracking tasks displayed on the Head-Up Display. Experimental variations included the feel system frequency, force-deflection gradient, control system command type (force or position input command), aircraft roll mode time constant, control system prefilter frequency, and control system time delay. The primary data were task performance records and evaluation pilot comments and ratings using the Cooper-Harper scale. The data highlight the unique and powerful effect of the feel system of flying qualities. The data show that the feel system is not 'equivalent' in flying qualities influence to analogous control system elements. A lower limit of allowable feel system frequency appears warranted to ensure good lateral flying qualities. Flying qualities criteria should most properly treat the feel system dynamic influence separately from the control system, since the input and output of this dynamic element is apparent to the pilot and thus, does not produce a 'hidden' effect.

  19. Strengthening the regulatory system through the implementation and use of a quality management system

    Directory of Open Access Journals (Sweden)

    Reinhold Eisner

    2017-04-01

    Full Text Available ABSTRACT Quality management systems (QMS, based on ISO 9001 requirements, are applicable to government service organizations such as Health Canada’s Biologics and Genetic Therapies Directorate (BGTD. This communication presents the process that the BGTD followed since the early 2000s to implement a quality management system and describes how the regulatory system was improved as a result of this project. BGTD undertook the implementation of a quality management system based on ISO 9001 and containing aspects of ISO 17025 with the goal of strengthening the regulatory system through improvements in the people, processes, and services of the organization. We discuss the strategy used by BGTD to implement the QMS and the benefits that were realized from the various stages of implementation. The eight quality principals upon which the QMS standards of the ISO 9000 series are based were used by senior management as a framework to guide QMS implementation.

  20. Software Quality Measurement for Distributed Systems. Volume 3. Distributed Computing Systems: Impact on Software Quality.

    Science.gov (United States)

    1983-07-01

    Distributed Computing Systems impact DrnwrR - aehR on Sotwar Quaity. PERFORMING 010. REPORT NUMBER 7. AUTNOW) S. CONTRACT OR GRANT "UMBER(*)IS ThomasY...C31 Application", "Space Systems Network", "Need for Distributed Database Management", and "Adaptive Routing". This is discussed in the last para ...data reduction, buffering, encryption, and error detection and correction functions. Examples of such data streams include imagery data, video

  1. Enhancing lean supply chain through traffic light quality management system

    Directory of Open Access Journals (Sweden)

    Md. Mazharul Islam

    2013-03-01

    Full Text Available Lean is a continuous journey to grow and excel the company. Any company want to develop and cope with the world pace must adopt lean. However, in most of the organizations the management culture or people’s mentality is not so good to embrace change. They have predestined mind set where no change is normally allowed. Lean is a cooperative way of working that involves all departments and all personnel to work together in a team for the betterment of the entire company. Without providing fixed solution of any problem it suggests the best way that people willingly accept to do. Lean normally deals with highest quality, shorter lead time and lowest cost. In Bangladesh, most of the garment manufacturing companies are experiencing a massive quality problem. We describe a case where traffic light, a tool of lean quality system was adopted to a garment manufacturing company in Bangladesh. We also provide the charts to contrast the before and after scenario in detail, in order to illustrate the company benefits. After the traffic light system being implemented, the quality status was improved, production capacity was increased; significant days were saved that enhanced the lead time and thus strengthen the supply chain.

  2. A rapid response air quality analysis system for use in projects having stringent quality assurance requirements

    International Nuclear Information System (INIS)

    Bowman, A.W.

    1990-01-01

    This paper describes an approach to solve air quality problems which frequently occur during iterations of the baseline change process. From a schedule standpoint, it is desirable to perform this evaluation in as short a time as possible while budgetary pressures limit the size of the staff available to do the work. Without a method in place to deal with baseline change proposal requests the environment analysts may not be able to produce the analysis results in the time frame expected. Using a concept called the Rapid Response Air Quality Analysis System (RAAS), the problems of timing and cost become tractable. The system could be adapted to assess other atmospheric pathway impacts, e.g., acoustics or visibility. The air quality analysis system used to perform the EA analysis (EA) for the Salt Repository Project (part of the Civilian Radioactive Waste Management Program), and later to evaluate the consequences of proposed baseline changes, consists of three components: Emission source data files; Emission rates contained in spreadsheets; Impact assessment model codes. The spreadsheets contain user-written codes (macros) that calculate emission rates from (1) emission source data (e.g., numbers and locations of sources, detailed operating schedules, and source specifications including horsepower, load factor, and duty cycle); (2) emission factors such as those published by the U.S. Environmental Protection Agency, and (3) control efficiencies

  3. Groundwater Quality Assessment Based on Geographical Information System and Groundwater Quality Index

    Directory of Open Access Journals (Sweden)

    Zahra Derakhshan

    2015-06-01

    Full Text Available Iran is located in an arid and semi-arid part of the world. Accordingly, the management of the water resources in the country is a priority. In this regard, determining the quality and pollution of surface water and groundwater is very important, especially in areas where groundwater resources are used for drinking. Groundwater quality index (GQI checks the components of the available water with various quality levels. To assess the quality of drinking groundwater of Yazd-Ardakan plain according to GQI in geographical information system (GIS environment, the electrical conductivity, sodium, calcium, magnesium, chlorine, pH, sodium adsorption ratio, bicarbonate, sulfate, potassium, water hardness, and all substances dissolved in the waters of 80 wells were determined. The samples were obtained from Yazd Regional Water Organization from 2005 to 2014. Using this data, the map components were plotted by Kriging geostatistical method. Then, the map of GQI was prepared after normalizing each map component, switching to a rating map, and extracting the weight of each component from the rating map. Based on the GQI index map, the index point which was 87 in 2005 has increased to 81 in 2014. These maps show a decline in groundwater quality from west to the east region. This decline in groundwater quality is due to the existence of Neogene Organizations in the east and geomorphologic unit of the bare epandage pediment in the west. The map removal and single-parameter sensitivity analysis showed that GQI index in Yazd-Ardakan plain is more sensitive to the components of electrical conductivity (EC, total dissolved solids (TDS, and total hardness (TH. Therefore, these components should be monitored more carefully and repeatedly.

  4. SME's Implementing a Quality Management System- Risks and Opportunities

    Directory of Open Access Journals (Sweden)

    Luise ZEININGER

    2017-12-01

    Full Text Available Part of our daily lives, risk ceased to be just something that managers are desperate to alleviate if not eliminate. It is now rightfully considered a path to explore new opportunities. The last version of the ISO 9001, the 2015 edition, is asking from organization implementing it to determine the risk and opportunities associated with their main processes, the impact over relevant third parties and the context, both internal and external. With this duality as starting point, we have investigated among SME's implementing a quality management system what would they consider to be the risk and opportunities associated to this action. Our paper presents hereinafter the partial results of a wider study on Romanian SME's management, especially the findings related to what managers consider as risk or opportunity when implementing a quality management system.

  5. Integrated evolutionary computation neural network quality controller for automated systems

    Energy Technology Data Exchange (ETDEWEB)

    Patro, S.; Kolarik, W.J. [Texas Tech Univ., Lubbock, TX (United States). Dept. of Industrial Engineering

    1999-06-01

    With increasing competition in the global market, more and more stringent quality standards and specifications are being demands at lower costs. Manufacturing applications of computing power are becoming more common. The application of neural networks to identification and control of dynamic processes has been discussed. The limitations of using neural networks for control purposes has been pointed out and a different technique, evolutionary computation, has been discussed. The results of identifying and controlling an unstable, dynamic process using evolutionary computation methods has been presented. A framework for an integrated system, using both neural networks and evolutionary computation, has been proposed to identify the process and then control the product quality, in a dynamic, multivariable system, in real-time.

  6. Provider and systems factors in diabetes quality of care.

    Science.gov (United States)

    Ghaznavi, Kimia; Malik, Shaista

    2012-02-01

    A gap exists in knowledge and the observed frequency with which patients with diabetes actually receive treatment for optimal cardiovascular risk reduction. Many interventions to improve quality of care have been targeted at the health systems level and provider organizations. Changes in several domains of care and investment in quality by organizational leaders are needed to make long-lasting improvements. In the studies reviewed, the most effective strategies often have multiple components, whereas the use of one single strategy, such as reminders only or an educational intervention, is less effective. More studies are needed to examine the effect of several care management strategies simultaneously, such as use of clinical information systems, provider financial incentives, and organizational model on processes of care and outcomes.

  7. Quality assurance considerations for nuclear power system selection

    International Nuclear Information System (INIS)

    Bender, M.

    1977-01-01

    The key quality assurance principle to be applied in nuclear system selection is to establish that the technological basis is understood and used properly. Knowledgeable and capable personnel with experience in the application are needed, and they must have access to appropriate engineering, laboratory, and manufacturing facilities. A suitable balance must be maintained between the responsibilities of the seller-supplier and the purchaser-owner to assure an even-handed treatment of the implementation program. Safety and reliability must be inherent to the regulatory framework. There must be flexibility in the purchaser-owner resources to overcome unanticipated adversity. Given these quality assurance elements, the nuclear system selection process should result in a high probability that the performance objectives will be satisfied

  8. Quality management system of Saraykoy Nuclear Research and Training center

    International Nuclear Information System (INIS)

    Gurellier, R.; Akchay, S.; Zararsiz, S.

    2014-01-01

    Full text : Technical competence and national/international acceptance of independency of laboratories is ensured by going through accreditations. It provides decreasing the risk of a slowdown in international trade due to unnecessary repetition of testing and analyses. It also eliminates the cost of additional experiments and analyses. Saraykoy Nuclear Research and Training Center (SANAEM) has performed intensive studies to establish an effective and well-functioning QMS (Quality Management System) by full accordance with the requirements of ISO/IEC 17025, since the begining of 2006. Laboratories, especially serving to public health studies and important trade duties require urgent accreditation. In this regard, SANAEM has established a quality management system and performed accreditation studies

  9. Physical image quality of computed radiography in mammography system

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Isa; Wan Muhamad Saridan Wan Hassan; Fatimah Othman

    2013-01-01

    Full-text: Mammography is a screening procedure that mostly used for early detection of breast cancer. In digital imaging system, Computed Radiography is a cost-effective technology that applied indirect conversion detector. The paper presents physical image quality parameter measurements namely modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of Computed Radiography in mammography system. MTF was calculated from two different orientations of slanted images of an edge test device and NNPS was estimated using flat-field image. Both images were acquired using a standard mammography beam quality. DQE was determined by applying the MTF and NNPS values into our developed software program. Both orientations have similar DQE characteristics. (author)

  10. IMPLEMENTATION OF INTEGRAL SYSTEM OF QUALITY MANAGEMENT IN TOURISM

    Directory of Open Access Journals (Sweden)

    Vidoje Vujic

    2007-12-01

    Full Text Available Theory and practice have corroborated the need and usefulness of an integral approach to quality management in tourist destinations, since the destination and its touristic offer define a number of disparate participants and interested parties. An integral system of quality management is one of the models of touristic management that with the implementation of contemporary principles strives to achieve business excellence and competitory advantage. The paper determines and projects the need and importance of implementing an integral system and accordingly seeks to form a model for its development. By studying the oneness of the whole we have established the dependence and firm connections between particular norms and elements, and by analyzing them in this paper we describe the structure and associated characteristics of the whole.

  11. Quality control in PET systems employing 2-D modular detectors

    International Nuclear Information System (INIS)

    Daghighian, F.; Hoffman, E.J.; Huang, S.C.

    1989-01-01

    Many new PET scanner designs employ 2-D detector modules to cost effectively achieve higher image and axial resolution. These systems are potentially less stable than older designs and the loss of a single photomultiplier can disable a large section of a multislice PET system. Because of these factors, it is now necessary to develop more sophisticated quality control procedures that are designed to detect problems as early as possible. The authors have developed and put into operation three automated quality control procedure that are designed to detect problems quickly with a minimum effort on the part of the user. These tests check: (1) stability of the detector modules in terms of efficiency, (2) resolution and its uniformity, (3) the reproducibility of the data

  12. Intelligent Systems Approaches to Product Sound Quality Analysis

    Science.gov (United States)

    Pietila, Glenn M.

    As a product market becomes more competitive, consumers become more discriminating in the way in which they differentiate between engineered products. The consumer often makes a purchasing decision based on the sound emitted from the product during operation by using the sound to judge quality or annoyance. Therefore, in recent years, many sound quality analysis tools have been developed to evaluate the consumer preference as it relates to a product sound and to quantify this preference based on objective measurements. This understanding can be used to direct a product design process in order to help differentiate the product from competitive products or to establish an impression on consumers regarding a product's quality or robustness. The sound quality process is typically a statistical tool that is used to model subjective preference, or merit score, based on objective measurements, or metrics. In this way, new product developments can be evaluated in an objective manner without the laborious process of gathering a sample population of consumers for subjective studies each time. The most common model used today is the Multiple Linear Regression (MLR), although recently non-linear Artificial Neural Network (ANN) approaches are gaining popularity. This dissertation will review publicly available published literature and present additional intelligent systems approaches that can be used to improve on the current sound quality process. The focus of this work is to address shortcomings in the current paired comparison approach to sound quality analysis. This research will propose a framework for an adaptive jury analysis approach as an alternative to the current Bradley-Terry model. The adaptive jury framework uses statistical hypothesis testing to focus on sound pairings that are most interesting and is expected to address some of the restrictions required by the Bradley-Terry model. It will also provide a more amicable framework for an intelligent systems approach

  13. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  14. Current status of quality assurance of treatment planning systems

    International Nuclear Information System (INIS)

    Mijnheer, B.J.

    1997-01-01

    A review is given of the current status of quality assurance of treatment planning systems. At this moment only one comprehensive report is available. In order to review national activities a questionnaire has been distributed amongst national societies of medical physicists. From the 23 responding countries, 8 indicated that only limited efforts are underway, 8 answered that a working group is evaluating their specific national requirements while in 5 countries a document is drafted. The highlights of these reports have been summarized. (author)

  15. Hybrid power filter for advanced power quality in industrial systems

    Czech Academy of Sciences Publication Activity Database

    Švec, J.; Müller, Z.; Kasembe, A. G.; Tlustý, J.; Valouch, Viktor

    2013-01-01

    Roč. 103, october 2013 (2013), s. 157-167 ISSN 0378-7796 R&D Projects: GA AV ČR IAA200760703 Institutional research plan: CEZ:AV0Z20570509 Institutional support: RVO:61388998 Keywords : hybrid power filter * power quality * industrial system Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.595, year: 2013 http://www.sciencedirect.com/science/article/pii/S0378779613001417

  16. Module-based quality system functionality evaluation in production logistics

    Directory of Open Access Journals (Sweden)

    Mahmood Reza Khabbazi

    2016-04-01

    Practical implications: Due to the specification of system as domain design structure, all proposed BPMs, data models, and the actual database prototype are seen referential if not a solution as a practical “to-be” quality business process re-engineering template. Originality/value: this paper sets out to provide an explanatory approach using different practical technique at modeling steps as well as the prototype implementation.

  17. Evaluation of renal vascular in living donors before transplantation using dynamic contrast enhanced MR angiography

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Zhong Xin; Dong Yuru; Dong Yue; Ma Yi; Wu Chunnan

    2010-01-01

    Objective: To explore whether dynamic contrast-enhanced MRA (DCE MRA) can provide an effective assessment of renal vascular in living donors before transplantation. Methods: Thirty five healthy living renal donor candidates were scanned on MR system before transplantation. After injection of Gd-DTPA 1 ml in vein, a test-bolus scan was used to get the time delay of Gd-DTPA reaching renal artery. Then, a 3D T 1 -weighted fast low-angle shot sequence (3D FLASH) was performed in the coronal plane. The 3D FLASH scan would repeat four times with an inter-phase of 10 seconds. Thus, the imaging of the renal arterial, venous and collecting systems were got. Two radiologists observed renal arteries and veins on original imaging and MIP reconstmcted imaging. The quality of MR angiography was evaluated on a five- point scale and the vascular anatomy or variations of the arterial and venous systems were recorded, using intraoperative findings as a standard of reference. Results: The quality for all MRA was good or very good for the most of living renal donors. Among 70 renals, several variations of vascular were found, including 5 left accessory artery, 9 right accessory artery, 3 left proximal arterial branch and 6 right proximal arterial branch. Among 70 renal veins, 1 right accessory veins and 2 left varicocele were observed. One small accessory artery of right kidney was missed with DCE MRA, but identified by operation. Conclusion: DCE MRA was noninvasive tool for evaluation of the renal vasculature and variations with high accuracy. It would be a good modality in preoperative evaluation of living renal donors. (authors)

  18. A Quality-Driven Methodology for Information Systems Integration

    Directory of Open Access Journals (Sweden)

    Iyad Zikra

    2017-10-01

    Full Text Available Information systems integration is an essential instrument for organizations to attain advantage in today’s growing and fast changing business and technology landscapes. Integration solutions generate added value by combining the functionality and services of heterogeneous and diverse systems. Existing integration environments tend to rely heavily on technical, platform-dependent skills. Consequently, the solutions that they enable are not optimally aligned with the envisioned business goals of the organization. Furthermore, the gap between the goals and the solutions complicates the task of evaluating the quality of integration solutions. To address these challenges, we propose a quality-driven, model-driven methodology for designing and developing integration solutions. The methodology spans organizational and systems design details, providing a holistic view of the integration solution and its underlying business goals. A multi-view meta-model provides the basis for the integration design. Quality factors that affect various aspects of the integration solution guide and inform the progress of the methodology. An example business case is presented to demonstrate the application of the methodology.

  19. Estimating Spoken Dialog System Quality with User Models

    CERN Document Server

    Engelbrecht, Klaus-Peter

    2013-01-01

    Spoken dialog systems have the potential to offer highly intuitive user interfaces, as they allow systems to be controlled using natural language. However, the complexity inherent in natural language dialogs means that careful testing of the system must be carried out from the very beginning of the design process.   This book examines how user models can be used to support such early evaluations in two ways:  by running simulations of dialogs, and by estimating the quality judgments of users. First, a design environment supporting the creation of dialog flows, the simulation of dialogs, and the analysis of the simulated data is proposed.  How the quality of user simulations may be quantified with respect to their suitability for both formative and summative evaluation is then discussed. The remainder of the book is dedicated to the problem of predicting quality judgments of users based on interaction data. New modeling approaches are presented, which process the dialogs as sequences, and which allow knowl...

  20. Quality assurance system in electric power companies in Japan, (2)

    International Nuclear Information System (INIS)

    Hamaguchi, Shun-ichi

    1980-01-01

    The organization for the quality assurance in nuclear power plants of Kansai Electric Power Co., Inc. is introduced. It is still in investigation stage what quality assurance (QA) organization and system is the best. The QA investigation project team was organized in the form directly supervised by the Office of President. The purpose of QA in operation is to maintain the functions of power plants in good condition over the lifetime of the power plants after starting the operation, and the QA is divided into the following five items: (1) running operation, (2) check-up and maintenance, (3) in-service testing and inspection, (4) regular inspection, (5) general application control. The purposes and works to be implemented for these items are listed in a table, and explained in detail. The quality control in regular inspection is described about 4 stages is purchase order and contract, design, construction, and adjusting operation. Also further improvement of QA in operating nuclear power plants by implementing the next items has been decided to make the most of the teachings in the accident of Three Mile Island plant. (1) Reinforcement of operation management system, (2) completion of the training for operators, (3) clarification of the command system for operational control, and (4) change of installations and review of application. As seen in the above description, the important tasks in QA activities are the matching to the existing installations and the adjustment of interfaces with the equipments in operation. (Wakatsuki, Y.)