WorldWideScience

Sample records for quality control survey

  1. Quality control in public participation assessments of water quality: the OPAL Water Survey.

    Science.gov (United States)

    Rose, N L; Turner, S D; Goldsmith, B; Gosling, L; Davidson, T A

    2016-07-22

    Public participation in scientific data collection is a rapidly expanding field. In water quality surveys, the involvement of the public, usually as trained volunteers, generally includes the identification of aquatic invertebrates to a broad taxonomic level. However, quality assurance is often not addressed and remains a key concern for the acceptance of publicly-generated water quality data. The Open Air Laboratories (OPAL) Water Survey, launched in May 2010, aimed to encourage interest and participation in water science by developing a 'low-barrier-to-entry' water quality survey. During 2010, over 3000 participant-selected lakes and ponds were surveyed making this the largest public participation lake and pond survey undertaken to date in the UK. But the OPAL approach of using untrained volunteers and largely anonymous data submission exacerbates quality control concerns. A number of approaches were used in order to address data quality issues including: sensitivity analysis to determine differences due to operator, sampling effort and duration; direct comparisons of identification between participants and experienced scientists; the use of a self-assessment identification quiz; the use of multiple participant surveys to assess data variability at single sites over short periods of time; comparison of survey techniques with other measurement variables and with other metrics generally considered more accurate. These quality control approaches were then used to screen the OPAL Water Survey data to generate a more robust dataset. The OPAL Water Survey results provide a regional and national assessment of water quality as well as a first national picture of water clarity (as suspended solids concentrations). Less than 10 % of lakes and ponds surveyed were 'poor' quality while 26.8 % were in the highest water quality band. It is likely that there will always be a question mark over untrained volunteer generated data simply because quality assurance is uncertain

  2. Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea

    International Nuclear Information System (INIS)

    Choe, Jae Gol; Joh, Cheol Woo

    2008-01-01

    It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's' quality control practice. This survey is done by collection of formatted questionnaire by mails, e mails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory

  3. Regional quality control survey of blood-gas analysis.

    Science.gov (United States)

    Minty, B D; Nunn, J F

    1977-09-01

    We undertook an external quality control survey of blood-gas analysis in 16 laboratories at 13 hospitals. All samples were prepared in the laboratories under investigation by equilibration of blood or serum with gas mixtures of known composition. pH of serum was measured with no significant bias but with an SD of random error 0.026 pH units, which was almost twice the SD of the reference range (0.015). An acceptable random error (half SD of reference range) was not obtained in a longitudinal internal quality control suvey although there were acceptable results for buffer pH in both field and internal surveys. Blood PO2 was measured with no significant bias but with SD of random error 1.38 kPa which reduced to 0.72 kPa by excluding one egregious result. The latter value was just over half of the SD of the reference range (1.2 kPa). PCO2 of blood was also measured without significant bias but with a much smaller SD of random error of 0.28 kPa (by excluding one egregious result), which was again just over half the SD of the reference range (0.51 kPa). Measurements of blood PO2 and PCO2 seem generally acceptable in relation to their respective reference ranges but measurements of pH were unsatisfactory in both internal and external trials.

  4. Results of quality control surveys of radioimmunological determinations of thyrotropin in newborns

    International Nuclear Information System (INIS)

    Roehle, G.; Kruse, R.; Voigt, U.; Torresani, T.

    1983-01-01

    Within the quality control scheme of the Deutsche Gesellschaft fuer Klinische Chemie, seven quality control surveys of thyrotropin (TSH) determinations in blood dried on filter paper have been carried out since 1980. Ninety-six screening laboratories from 12 European countries took part in these surveys. In a single survey each participant usually analysed four different samples; each of these consisted of three spots of dried blood spiked with defined amounts of thyrotropin. For the evaluations of the surveys the participants were asked to give information about their analytical results, and from these, their diagnostic classifications. The medians of the analytical results correlated well with the given thyrotropin concentrations, but the individual estimations from different laboratories varied greatly. Major discrepancies of classification were also apparent, both in the given thyrotropin concentrations and in the individual estimations. Two special collaborative studies with nine selected laboratories showed on the one hand that analysis of the largest possible part of the dried blood sample can help to optimize the precision of the results; on the other hand, considerable drawbacks related to the reagents and the methods were sometimes observed. (orig.) [de

  5. DEVELOPMENT AND APPLICATION OF THE KEY TECHNOLOGIES FOR THE QUALITY CONTROL AND INSPECTION OF NATIONAL GEOGRAPHICAL CONDITIONS SURVEY PRODUCTS

    Directory of Open Access Journals (Sweden)

    Y. Zhao

    2018-04-01

    Full Text Available The First National Geographical Condition Survey is a predecessor task to dynamically master basic situations of the nature, ecology and human activities on the earth’s surface and it is the brand-new mapping geographic information engineering. In order to ensure comprehensive, real and accurate survey results and achieve the quality management target which the qualified rate is 100 % and the yield is more than 80 %, it is necessary to carry out the quality control and result inspection for national geographical conditions survey on a national scale. To ensure that achievement quality meets quality target requirements, this paper develops the key technology method of “five-in-one” quality control that is constituted by “quality control system of national geographical condition survey, quality inspection technology system, quality evaluation system, quality inspection information management system and national linked quality control institutions” by aiming at large scale, wide coverage range, more undertaking units, more management levels, technical updating, more production process and obvious regional differences in the national geographical condition survey and combining with novel achievement manifestation, complicated dependency, more special reference data, and large data size. This project fully considering the domestic and foreign related research results and production practice experience, combined with the technology development and the needs of the production, it stipulates the inspection methods and technical requirements of each stage in the quality inspection of the geographical condition survey results, and extends the traditional inspection and acceptance technology, and solves the key technologies that are badly needed in the first national geographic survey.

  6. Development and Application of the Key Technologies for the Quality Control and Inspection of National Geographical Conditions Survey Products

    Science.gov (United States)

    Zhao, Y.; Zhang, L.; Ma, W.; Zhang, P.; Zhao, T.

    2018-04-01

    The First National Geographical Condition Survey is a predecessor task to dynamically master basic situations of the nature, ecology and human activities on the earth's surface and it is the brand-new mapping geographic information engineering. In order to ensure comprehensive, real and accurate survey results and achieve the quality management target which the qualified rate is 100 % and the yield is more than 80 %, it is necessary to carry out the quality control and result inspection for national geographical conditions survey on a national scale. To ensure that achievement quality meets quality target requirements, this paper develops the key technology method of "five-in-one" quality control that is constituted by "quality control system of national geographical condition survey, quality inspection technology system, quality evaluation system, quality inspection information management system and national linked quality control institutions" by aiming at large scale, wide coverage range, more undertaking units, more management levels, technical updating, more production process and obvious regional differences in the national geographical condition survey and combining with novel achievement manifestation, complicated dependency, more special reference data, and large data size. This project fully considering the domestic and foreign related research results and production practice experience, combined with the technology development and the needs of the production, it stipulates the inspection methods and technical requirements of each stage in the quality inspection of the geographical condition survey results, and extends the traditional inspection and acceptance technology, and solves the key technologies that are badly needed in the first national geographic survey.

  7. Crowdsourcing quality control for Dark Energy Survey images

    Science.gov (United States)

    Melchior, P.; Sheldon, E.; Drlica-Wagner, A.; Rykoff, E. S.; Abbott, T. M. C.; Abdalla, F. B.; Allam, S.; Benoit-Lévy, A.; Brooks, D.; Buckley-Geer, E.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Crocce, M.; D'Andrea, C. B.; da Costa, L. N.; Desai, S.; Doel, P.; Evrard, A. E.; Finley, D. A.; Flaugher, B.; Frieman, J.; Gaztanaga, E.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; Honscheid, K.; James, D. J.; Jarvis, M.; Kuehn, K.; Li, T. S.; Maia, M. A. G.; March, M.; Marshall, J. L.; Nord, B.; Ogando, R.; Plazas, A. A.; Romer, A. K.; Sanchez, E.; Scarpine, V.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Vikram, V.; Walker, A. R.; Wester, W.; Zhang, Y.

    2016-07-01

    We have developed a crowdsourcing web application for image quality control employed by the Dark Energy Survey. Dubbed the "DES exposure checker", it renders science-grade images directly to a web browser and allows users to mark problematic features from a set of predefined classes. Users can also generate custom labels and thus help identify previously unknown problem classes. User reports are fed back to hardware and software experts to help mitigate and eliminate recognized issues. We report on the implementation of the application and our experience with its over 100 users, the majority of which are professional or prospective astronomers but not data management experts. We discuss aspects of user training and engagement, and demonstrate how problem reports have been pivotal to rapidly correct artifacts which would likely have been too subtle or infrequent to be recognized otherwise. We conclude with a number of important lessons learned, suggest possible improvements, and recommend this collective exploratory approach for future astronomical surveys or other extensive data sets with a sufficiently large user base. We also release open-source code of the web application and host an online demo version at http://des-exp-checker.pmelchior.net.

  8. National survey on internal quality control for tumour markers in clinical laboratories in China.

    Science.gov (United States)

    Wang, Wei; Zhong, Kun; Yuan, Shuai; He, Falin; Du, Yuxuan; Hu, Zhehui; Wang, Zhiguo

    2018-06-15

    This survey was initiated to obtain knowledge on the current situation of internal quality control (IQC) practice for tumour markers (TMs) in China. Additionally, we tried to acquire the most appropriate quality specifications. This survey was a current status survey. The IQC information had been collected via online questionnaires. All of 1821 clinical laboratories which participated in the 2016 TMs external quality assessment (EQA) programme had been enrolled. The imprecision evaluation criteria were the minimal, desirable, and optimal allowable imprecisions based on biological variations, and 1/3 total allowable error (TEa) and 1/4 TEa. A total of 1628 laboratories answered the questionnaires (89%). The coefficients of variation (CVs) of the IQC of participant laboratories varied greatly from 1% (5 th percentile) to 13% (95 th percentile). More than 82% (82 - 91%) of participant laboratories two types of CVs met 1/3 TEa except for CA 19-9. The percentiles of current CVs were smaller than cumulative CVs. A number of 1240 laboratories (76%) reported their principles and systems used. The electrochemiluminescence was the most used principle (45%) and had the smallest CVs. The performance of laboratories for TMs IQC has yet to be improved. On the basis of the obtained results, 1/3 TEa would be realistic and attainable quality specification for TMs IQC for clinical laboratories in China.

  9. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  10. Quality Control in Survey Design: Evaluating a Survey of Educators’ Attitudes Concerning Differentiated Compensation

    OpenAIRE

    Kelly D. Bradley; Michael Peabody; Shannon O. Sampson

    2015-01-01

    This study utilized the Rasch model to assess the quality of a survey instrument designed to measure attitudes of administrators and teachers concerning a differentiated teacher compensation program piloted in Kentucky.  Researchers addressing potentially contentious issues should ensure their methods stand up to rigorous criticism.  The results indicate that the rating scale does not function as expected, with items being too easy to endorse.  Future iterations of this survey should be revis...

  11. 2015/2016 Quality Risk Management Benchmarking Survey.

    Science.gov (United States)

    Waldron, Kelly; Ramnarine, Emma; Hartman, Jeffrey

    2017-01-01

    This paper investigates the concept of quality risk management (QRM) maturity as it applies to the pharmaceutical and biopharmaceutical industries, using the results and analysis from a QRM benchmarking survey conducted in 2015 and 2016. QRM maturity can be defined as the effectiveness and efficiency of a quality risk management program, moving beyond "check-the-box" compliance with guidelines such as ICH Q9 Quality Risk Management , to explore the value QRM brings to business and quality operations. While significant progress has been made towards full adoption of QRM principles and practices across industry, the full benefits of QRM have not yet been fully realized. The results of the QRM Benchmarking Survey indicate that the pharmaceutical and biopharmaceutical industries are approximately halfway along the journey towards full QRM maturity. LAY ABSTRACT: The management of risks associated with medicinal product quality and patient safety are an important focus for the pharmaceutical and biopharmaceutical industries. These risks are identified, analyzed, and controlled through a defined process called quality risk management (QRM), which seeks to protect the patient from potential quality-related risks. This paper summarizes the outcomes of a comprehensive survey of industry practitioners performed in 2015 and 2016 that aimed to benchmark the level of maturity with regard to the application of QRM. The survey results and subsequent analysis revealed that the pharmaceutical and biopharmaceutical industries have made significant progress in the management of quality risks over the last ten years, and they are roughly halfway towards reaching full maturity of QRM. © PDA, Inc. 2017.

  12. The 21th quality control survey for radioisotope in vitro tests in Japan, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Shishiba, Yoshimasa; Shimizu, Taeko [Toranomon Hospital, Tokyo (Japan); Ichihara, Kiyoshi; Kousaka, Tadako; Kobayashi, Hisae; Tachibana, Katsuhiko; Tsushima, Toshio; Hoshino, Minoru; Mori, Mikio

    2000-10-01

    The quality control survey in the title has been conducted every year from 1978 to improve the quality of the in vitro tests and this report gives the survey results done in 1999. The survey was performed in 133 facilities out of 283 in Japan, which involved 18 national and public university hospitals, 16 private university hospitals, 19 national and public hospitals, 18 private hospitals, 41 hygiene test institutes and 21 reagent manufacturers. Tests examined were on 6 substances related to functions of pituitary, 5 of thyroid function, 1 of parathyroid, 4 of digestive-pancreas, 5 of gonad-placenta, 4 of adrenal and 1 of renal-blood pressure regulation, on IgE, on digoxin and on 11 tumor-related substances. Tests were done on 2 - 3 samples supplied from the Committee and for reproducibility for within-day, between-day, effects of freeze-thaw and periodic variation after thawing. Methods involved those using non-radioisotopes like enzyme immunoassay as well as those using radioactive isotopes like radioimmunoassay. Results given by the mean, standard deviation and coefficient of variation for each kit, were analyzed for within-kit (between-facility) variation and between-kit (between-reagent) variation by one way analysis of variance. Findings were similar to those previously reported without the particular new problem; however, the committee considered that the survey should be done with human serum as a matrix especially for samples with a high matrix effect in future. (K.H.)

  13. The 12th quality control survey for radioisotope in vitro tests in Japan, 1990

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    The results of the 12th quality control nationwide survey is presented. Of 670 selected facilities, 405 (60.4%) participated in this survey. Myoglobin and trypsin were added as new items to be examined. The other conventional items were as follows: alpha-fetoprotein (AFP), aldosterone, {beta}{sub 2}-microglobulin, carbohydrate angigen 15-3, C-peptide, digoxin, elastase 1, free triiodothyronine, growth hormone, immunoglobulin E, prostatic acid phosphatase, pancreatic secretory trypsin inhibitor, progesterone, prolactin, thyroglobulin, triiodothyronine (T{sub 3}), T{sub 3} uptake, tissue polypeptide antigen, thyroid stimulating hormone, and testosterone. There was a great coefficient of variation (CV) between kits in AFP, aldosterone, progesterone, and prolactin. These results were analogous to those in the previous surveys. For T{sub 3}, there was a great difference between CV by radioimmunoassay and by non-isotopic method. Both myoglobin and trypsin had a great difference between kits. (N.K.).

  14. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  15. Survey of the prevalence and methodology of quality assurance for B-mode ultrasound image quality among veterinary sonographers.

    Science.gov (United States)

    Hoscheit, Larry P; Heng, Hock Gan; Lim, Chee Kin; Weng, Hsin-Yi

    2018-05-01

    Image quality in B-mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B-mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B-mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross-sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34-52%) and 26% (40/156: 95% confidence interval 19-33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0-6%, quality control testing 95% confidence interval: 0-11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B-mode ultrasound equipment/components. © 2018 American College of Veterinary Radiology.

  16. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  17. Optimising UAV topographic surveys processed with structure-from-motion: Ground control quality, quantity and bundle adjustment

    Science.gov (United States)

    James, Mike R.; Robson, Stuart; d'Oleire-Oltmanns, Sebastian; Niethammer, Uwe

    2016-04-01

    Structure-from-motion (SfM) algorithms are greatly facilitating the production of detailed topographic models based on images collected by unmanned aerial vehicles (UAVs). However, SfM-based software does not generally provide the rigorous photogrammetric analysis required to fully understand survey quality. Consequently, error related to problems in control point data or the distribution of control points can remain undiscovered. Even if these errors are not large in magnitude, they can be systematic, and thus have strong implications for the use of products such as digital elevation models (DEMs) and orthophotos. Here, we develop a Monte Carlo approach to (1) improve the accuracy of products when SfM-based processing is used and (2) reduce the associated field effort by identifying suitable lower density deployments of ground control points. The method highlights over-parameterisation during camera self-calibration and provides enhanced insight into control point performance when rigorous error metrics are not available. Processing was implemented using commonly-used SfM-based software (Agisoft PhotoScan), which we augment with semi-automated and automated GCPs image measurement. We apply the Monte Carlo method to two contrasting case studies - an erosion gully survey (Taurodont, Morocco) carried out with an fixed-wing UAV, and an active landslide survey (Super-Sauze, France), acquired using a manually controlled quadcopter. The results highlight the differences in the control requirements for the two sites, and we explore the implications for future surveys. We illustrate DEM sensitivity to critical processing parameters and show how the use of appropriate parameter values increases DEM repeatability and reduces the spatial variability of error due to processing artefacts.

  18. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  19. 77 FR 21086 - Patents External Quality Survey (formerly Customer Panel Quality Survey)

    Science.gov (United States)

    2012-04-09

    ... corporations (including those with 500+ employees), small and medium-size businesses, and universities and... DEPARTMENT OF COMMERCE United States Patent and Trademark Office Patents External Quality Survey... their name, address, or Social Security Number. In order to access and complete the online survey...

  20. The 11th quality control survey for radioisotopes in vitro tests in Japan, 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-10-01

    This report presents the results of the 11th quality control nationwide survey. Of 730 facilities performing radioisotopes in vitro tests in November 1989, 422 facilities (60.5%) participated in the present survey. The following 23 items were examined: adrenocorticotropic hormone (ACTH), albumin, carbohydrate antigen 125 (CA 125), carbohydrate antigen 19-9 (CA 19-9), carcinoembryonic antigen (CEA), calcitonin, cortisol, estradiol, ferritin, free thyroxine (FT{sub 4}), follicle stimulating hormone (FSH), gastrine, cholylglycine, glucagon, insulin, anti-DNA antibody, luteinizing hormone (LH), neuron specific enolase (NSE), parathyroid hormone (PTH), squamous cell carcinoma associated antigen (SCC), thyroxine (T{sub 4}), thyroxine binding globulin (TBG), and antithyroid stimulating hormone (TSH) receptor antibody. 'Within kit variation' between facilities showed large coefficient of variation for ACTH, CA125, CEA, estradiol, ferritin, FSH, glucagon, anti-DNA antibody, LH, PTH, and TSH receptor antibody. Both 'within kit variation' and 'between kit variation' showed small coefficient of variation for cortisol, free T{sub 4}, NSE, SCC, T{sub 4}, and TBG. The present survey was characterized by using immunoradiometric assay (IRMA) and non-isotope techniques, as well as radioimmunoassay. Kits for IRMA greatly varied from facility to facility. (N.K.).

  1. National Survey on Internal Quality Control for HbA(1c) Analytical Instruments in 331 Hospital Laboratories of China.

    Science.gov (United States)

    Zeng, Rong; Wang, Wei; Zhao, Haijian; Fei, Yang; Wang, Zhiguo

    2015-01-01

    The narrow gap of HbA1 value of mass fraction between "normal" (control of inter-assay standardization, assay precision, and trueness. This survey was initiated to obtain knowledge of the current situation of internal quality control (IQC) practice for HbA(1c) in China and find out the most appropriate quality specifications. Data of IQC for HbA(1c) in 331 institutions participating in the national proficiency testing (PT) programs in China were evaluated using four levels of quality specifications, and the percentages of laboratories meeting the quality requirement were calculated to find out the most appropriate quality specifications for control materials of HbA(1c) in China. The IQC data varied vastly among 331 clinical laboratories in China. The measurement of control materials covered a wide range from 4.52% to 12.24% (inter-quartile range) and there were significant differences among the CVs of different methods, including LPLC, CE-HPLC, AC-HPLC, immunoturbidimetry, and others. Among the four main methods, CE-HPLC and AC-HPLC achieved a better precision. As we can see, the performance of laboratories for HbA(1c) has yet to be improved. Clinical laboratories in China should improve their performance with a stricter imprecision criteria.

  2. External quality-control surveys of peptide hormone radioimmunoassays in the Federal Republic of Germany. The present status

    International Nuclear Information System (INIS)

    Breuer, H.; Jungbluth, D.; Roehle, G.; Marschner, I.; Scriba, P.C.; Wood, W.G.

    1978-01-01

    Two types of quality-control survey (QCS) of hormone assays are performed in the Federal Republic of Germany. In the one survey, the participating laboratories are requested to determine seven or eight different hormones in two lyophilized sera that are distributed several times a year. Because of the lack of reference methods for peptide hormones, the statistical evaluation of the results indicates only whether they are ''correct'' or subject to systematic or nonsystematic errors with respect to the findings of the other participants. In the other survey, the participating laboratories are requested to assay only one given hormone in some 20 deep-frozen sera (including standards in hormone-free sera for derivation of a standard curve) that are distributed at relatively long intervals. The statistical analysis of the data derived from these QCSs allows - together with the methodological inquiry form - detection of probable causes for discrepancies in the results. (author)

  3. Quality control in urinalysis.

    Science.gov (United States)

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  4. Summary, the 20th quality control survey for radioisotopes in vitro tests in Japan, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    For advancement of radioisotope in vitro tests such as radioimmunoassay and immunoradiometric assay, the Subcommittee for Radioisotope in vitro Test in Medical and Pharmaceutical Committee of Japan Radioisotope Association has conducted the yearly quality control survey for the test facilities in Japan since 1978. This is the summary of the 20th survey in 1998 where non-radioisotope tests like enzyme-immunoassay were involved as well. The survey was done for 143 facilities: 20 national and public university hospitals, 18 private university hospitals, 8 national hospitals, 13 public hospitals, 21 private hospitals, 41 hygienic laboratories and 22 manufacturers of reagents. Facilities examined intra- and between day-reproducibility, freeze-thaw effect and time change of the measured values on the same samples. Assays were for: growth hormone (h), somatomedin C, follicle stimulating h, luteinizing h, prolactin, thyroid stimulating h, triiodothyronines, thyroxines, thyroxine binding protein, calcitonin, insulin, C-peptide, glucagons, gastrin, testosterones, estradiol, progesterone, gonadotropin, 17{alpha}-hydroxyprogesterone, aldosterone, cortisol, dehydroepiandorosterone sulfate, renin, IgE, digoxin, {alpha}-fetoprotein, carcinoembryonic antigen, tissue polypeptide antigen, CA (125, 19-9 and 15-3), prostatic acid phosphatase, prostate specific antigen, {beta}2-microglobulin, ferritin, and neuron specific enolase. There was no great difference between this and last survey results although tendency of improvement was recognized. There were problems to be solved from the standpoint of clinical practice. (K.H.)

  5. Summary, the 16th quality control survey for radioisotope in vitro tests in Japan, 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The results of the 16th quality control survey for radioisotope in vitro tests in Japan (1994) are summarized. Of 399 medical facilities conducting radioisotope in vitro tests, 201 were enrolled in this study. Forty items including ACTH and {alpha}-fetoprotein were selected as the subjects. Freeze-drying samples were sent to the facilities. The quality of assay tubes, duration between fusion of the samples and assay, and the condition of preservation were examined, and those influence on the assay values were studied. Radioimmunoassay, immunoradiometric assay, and other procedures using enzymes, fluorescence, and chemiluminescense were conducted. The assay values of some of the items were significantly influenced by repeated freezing and fusion of the samples. Data were collected from individual items and kits used, and analyzed. The significant difference of values between different facilities and kits used were considered due to difference of assay principle, antibodies used, and standard items. The concentration of the samples needs to be improved. (S.Y.).

  6. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  7. A questionnaire survey of medical physicist and quality manager for radiation therapy

    International Nuclear Information System (INIS)

    Nishio, Teiji; Ashino, Yasuo; Onishi, Hiroshi

    2008-01-01

    A questionnaire survey of medical physicists and quality managers for radiation therapy was performed by the Japanese Society for Therapeutic Radiology and Oncology (JASTRO) Future Planning Committee. We mailed the questionnaire to 726 radiotherapy facilities with the answers returned from 353 radiotherapy facilities. The result showed 178 facilities were staffed by radiotherapy workers who were licensed medical physicists or quality managers. A staff of 289 was licensed radiotherapy workers. Most of the staff were radiotherapy technologists. Quality control for radiation therapy was rated satisfactory according to each facility's assessment. Radiation therapy of high quality requires continued education of medical physicists and quality managers, in addition to keeping up with times for quality control. (author)

  8. Survey on quality control measurements for nuclear medicine imaging equipment in Finland in 2006

    International Nuclear Information System (INIS)

    Korpela, Helinae; Niemelae, Jarkko

    2008-01-01

    Routine quality control (QC) is an essential requirement in nuclear medicine (NM) in order to ensure optimal functioning of equipment. To harmonise the routine QC of NM imaging equipment in Finnish hospital s (planar gamma cameras, SPECT, coincidence gamma cameras, PET), the Radiation and Nuclear Safety Authority (STUK) will publish guidelines on QC in collaboration with several hospital physicists. Recommendations will be provided on routine QC measurements and on the frequency of testing. It is also planned to provide recommendations for the acceptance criteria when assessing different performance parameters for NM imaging equipment. In order to determine what performance parameters of NM equipment are currently measured in hospitals, how frequently they are measured and what acceptance criteria are used, a survey was carried out on the QC of NM equipment in Finland during 2006. (author)

  9. Web-based X-ray quality control documentation.

    Science.gov (United States)

    David, George; Burnett, Lou Ann; Schenkel, Robert

    2003-01-01

    The department of radiology at the Medical College of Georgia Hospital and Clinics has developed an equipment quality control web site. Our goal is to provide immediate access to virtually all medical physics survey data. The web site is designed to assist equipment engineers, department management and technologists. By improving communications and access to equipment documentation, we believe productivity is enhanced. The creation of the quality control web site was accomplished in three distinct steps. First, survey data had to be placed in a computer format. The second step was to convert these various computer files to a format supported by commercial web browsers. Third, a comprehensive home page had to be designed to provide convenient access to the multitude of surveys done in the various x-ray rooms. Because we had spent years previously fine-tuning the computerization of the medical physics quality control program, most survey documentation was already in spreadsheet or database format. A major technical decision was the method of conversion of survey spreadsheet and database files into documentation appropriate for the web. After an unsatisfactory experience with a HyperText Markup Language (HTML) converter (packaged with spreadsheet and database software), we tried creating Portable Document Format (PDF) files using Adobe Acrobat software. This process preserves the original formatting of the document and takes no longer than conventional printing; therefore, it has been very successful. Although the PDF file generated by Adobe Acrobat is a proprietary format, it can be displayed through a conventional web browser using the freely distributed Adobe Acrobat Reader program that is available for virtually all platforms. Once a user installs the software, it is automatically invoked by the web browser whenever the user follows a link to a file with a PDF extension. Although no confidential patient information is available on the web site, our legal

  10. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Kueffer, K.

    1981-01-01

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  11. Design, analysis, and interpretation of field quality-control data for water-sampling projects

    Science.gov (United States)

    Mueller, David K.; Schertz, Terry L.; Martin, Jeffrey D.; Sandstrom, Mark W.

    2015-01-01

    The process of obtaining and analyzing water samples from the environment includes a number of steps that can affect the reported result. The equipment used to collect and filter samples, the bottles used for specific subsamples, any added preservatives, sample storage in the field, and shipment to the laboratory have the potential to affect how accurately samples represent the environment from which they were collected. During the early 1990s, the U.S. Geological Survey implemented policies to include the routine collection of quality-control samples in order to evaluate these effects and to ensure that water-quality data were adequately representing environmental conditions. Since that time, the U.S. Geological Survey Office of Water Quality has provided training in how to design effective field quality-control sampling programs and how to evaluate the resultant quality-control data. This report documents that training material and provides a reference for methods used to analyze quality-control data.

  12. Metrology and quality control handbook

    International Nuclear Information System (INIS)

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  13. Field Methods and Quality-Assurance Plan for Quality-of-Water Activities, U.S. Geological Survey, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Knobel, LeRoy L.; Tucker, Betty J.; Rousseau, Joseph P.

    2008-01-01

    Water-quality activities conducted by the staff of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation's water resources. The activities are conducted in cooperation with the U.S. Department of Energy's (DOE) Idaho Operations Office. Results of the water-quality investigations are presented in various USGS publications or in refereed scientific journals. The results of the studies are highly regarded, and they are used with confidence by researchers, regulatory and managerial agencies, and interested civic groups. In its broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the 'state-of-the-art' technology, and quality assurance ensures that quality control is maintained within specified limits.

  14. Survey of product quality control of radioactive waste

    International Nuclear Information System (INIS)

    Warnecke, E.

    1989-01-01

    The PTB has developed basic procedures with regard to deriving final storage conditions and product quality control. After this, requirements for radioactive waste are derived via safety analysers, in which information about the radioactive waste, the geological overall situation of the site and the layout of the final storage mine, in particular, are included as basic data. The final storage conditions are only determined with the awarding of the planning decision. Compliance with them can be proved by random sample tests on waste containers or via a qualification and inspection of the conditioning process. (DG) [de

  15. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  16. The 13th quality control survey for radioisotopes in vitro tests in Japan, 1991

    Energy Technology Data Exchange (ETDEWEB)

    1992-11-01

    This paper presents the results of the 13th quality control nationwide survey. Of 568 hospitals performing RI in vitro tests as of December 1991, 280 (49.3%) participated in this survey. The following 37 items were examined: ACTH, 17[alpha]-hydroxyprogesterone, [alpha]-fetoprotein, aldosterone, [beta]2-microglobulin, CA 125, CA 15-3, CA 19-9, calcitonin, CEA, cortisol, C-peptide, digoxin, esteradiol, ferritin, free triiodothyronine (T[sub 3]), free thyroxine (T[sub 4]), FSH, gastrin, GH, glucagon, IgE, insulin, LH, PAP, progesterone, prolactin, PTH, somatomedin C, T[sub 3], T[sub 4], T[sub 3] uptake, TBG, testosterone, thyroglobulin, tissue polypeptide antigen, and TSH. Reliability and safety of measurement values were evaluated based on protein components of serum samples, spontaneous reliability test, time-dependent reliability test, repeated freezing-dissolution test, and serial change test after freezing. 'Within kit variation' between facilities was great especially for ACTH, CA 15-3, CA 19-9, free T[sub 4], calcitonin, gastrin, and testosterone, and was favorable for [beta][sub 2]-microglobulin, CA 125, digoxin, cortisol, IgE, T[sub 3], T[sub 4], T[sub 3] uptake, and TBG. It was noted that there was a great difference in measurement values of free T[sub 3] and free-T[sub 4] between RIA kits and non-isotopic kits. (N.K.).

  17. Survey on Monitoring and Quality Controlling of the Mobile Biosignal Delivery.

    Science.gov (United States)

    Pawar, Pravin A; Edla, Damodar R; Edoh, Thierry; Shinde, Vijay; van Beijnum, Bert-Jan

    2017-10-31

    A Mobile Patient Monitoring System (MPMS) acquires patient's biosignals and transmits them using wireless network connection to the decision-making module or healthcare professional for the assessment of patient's condition. A variety of wireless network technologies such as wireless personal area networks (e.g., Bluetooth), mobile ad-hoc networks (MANET), and infrastructure-based networks (e.g., WLAN and cellular networks) are in practice for biosignals delivery. The wireless network quality-of-service (QoS) requirements of biosignals delivery are mainly specified in terms of required bandwidth, acceptable delay, and tolerable error rate. An important research challenge in the MPMS is how to satisfy QoS requirements of biosignals delivery in the environment characterized by patient mobility, deployment of multiple wireless network technologies, and variable QoS characteristics of the wireless networks. QoS requirements are mainly application specific, while available QoS is largely dependent on QoS provided by wireless network in use. QoS provisioning refers to providing support for improving QoS experience of networked applications. In resource poor conditions, application adaptation may also be required to make maximum use of available wireless network QoS. This survey paper presents a survey of recent developments in the area of QoS provisioning for MPMS. In particular, our contributions are as follows: (1) overview of wireless networks and network QoS requirements of biosignals delivery; (2) survey of wireless networks' QoS performance evaluation for the transmission of biosignals; and (3) survey of QoS provisioning mechanisms for biosignals delivery in MPMS. We also propose integrating end-to-end QoS monitoring and QoS provisioning strategies in a mobile patient monitoring system infrastructure to support optimal delivery of biosignals to the healthcare professionals.

  18. Knowledge Sharing, Control of Care Quality, and Innovation in Intensive Care Nursing

    DEFF Research Database (Denmark)

    Paunova, Minna; Li-Ying, Jason; Egerod, Ingrid Eugenie

    This study investigates the influence of nurse knowledge sharing behavior on nurse innovation, given different conditions of control of care quality within the intensive care unit (ICU). After conducting a number of interviews and a pilot study, we carried out a multi-source survey study of more...... control of care quality and innovate may be conflicting, unless handled properly....

  19. NGS Survey Control Map

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Survey Control Map provides a map of the US which allows you to find and display geodetic survey control points stored in the database of the National...

  20. Quality of Diabetes Care: The Challenges of an Increasing Epidemic in Mexico. Results from Two National Health Surveys (2006 and 2012).

    Science.gov (United States)

    Flores-Hernández, Sergio; Saturno-Hernández, Pedro J; Reyes-Morales, Hortensia; Barrientos-Gutiérrez, Tonatiuh; Villalpando, Salvador; Hernández-Ávila, Mauricio

    2015-01-01

    The quality of diabetes care remains suboptimal according to numerous studies assessing the achievement of quality indicators for diabetes care in various healthcare settings. We report about global and specific quality indicators for diabetes care and their association to glycemic control at the population level in two national health surveys in Mexico. We conducted a cross-sectional analysis of the 2006 and 2012 National Health Surveys in Mexico. We examined quality of care for 2,965 and 4,483 adults (≥ 20 years) with diagnosed type 2 diabetes using fourteen simple and two composite indicators derived from self-reported information. In a subsample for both surveys, glycated hemoglobin (HbA1c) was measured at the time of the interview. We obtained survey weight-adjusted estimators using multiple regression models (logistic and linear) with combined data files, including survey year as covariate to assess change. Global quality of care in 2012 was 40.8%, with a relative improvement of 11.7% between 2006 and 2012. Detections of cardiovascular disease risk factors (dyslipidemia and hypertension) were the indicators with the highest improvement, while non-pharmaceutical treatment and diabetic foot exams showed minor changes. We found a significant association between the quality of the process of diabetes care and glycemic control (OR 2.53, 95% CI 1.63-3.94). Age more than 65 years old, the type of health subsystem, gender (males), and high socio-economic status were also significantly associated to glycemic control. Quality diabetes care and glycemic control improved and are significantly associated. However, according to international standards, the current situation remains suboptimal. A more holistic approach is needed, with an emphasis on improving quality in outpatient care.

  1. Evaluation of quality assurance/quality control data collected by the U.S. Geological Survey for water-quality activities at the Idaho National Engineering and Environmental Laboratory, Idaho, 1994 through 1995

    International Nuclear Information System (INIS)

    Williams, L.M.

    1997-03-01

    More than 4,000 water samples were collected by the US Geological Survey (USGS) from 179 monitoring sites for the water-quality monitoring program at the Idaho National Engineering Laboratory from 1994 through 1995. Approximately 500 of the water samples were replicate or blank samples collected for the quality assurance/quality control program. Analyses were performed to determine the concentrations of major ions, nutrients, trace elements, gross radioactivity and radionuclides, total organic carbon, and volatile organic compounds in the samples. To evaluate the precision of field and laboratory methods, analytical results of the replicate pairs of samples were compared statistically for equivalence on the basis of the precision associated with each result. In all, the statistical comparison of the data indicated that 95% of the replicate pairs were equivalent. Within the major ion analyses, 97% were equivalent; nutrients, 88%; trace elements, 95%; gross radioactivity and radionuclides, 93%; and organic constituents, 98%. Ninety percent or more of the analytical results for each constituent were equivalent, except for nitrite, orthophosphate, phosphorus, aluminum, iron, strontium-90, and total organic carbon

  2. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  3. Survey-assessed quality and organizational factors related to quality in Pursuing Perfection hospitals.

    Science.gov (United States)

    Shwartz, Michael; Cramer, Irene E; Holmes, Sally K; Cohen, Alan B; Restuccia, Joseph D; VanDeusen Lukas, Carol; Sullivan, Jennifer L; Charns, Martin P

    2010-01-01

    The goal of the Pursuing Perfection (P2) program was to encourage organizations to push quality improvement to new levels of excellence. As part of an evaluation of P2, we surveyed employees at the 7 participating P2 organizations to (1) assess their perceptions of patient care quality and improvement progress and (2) examine perceived performance on organizational and workgroup characteristics associated with quality. Many survey questions were drawn from existing conceptual models and survey instruments. We used factor analysis to create new scales from questions that were not part of established scales. We used correlation coefficients and multivariable models to examine relationships among variables. Variables most strongly associated with perceived quality included standardized and simplified care processes resulting in coordinated care and smooth handoffs, a clear sense of organizational direction and clear action plans, and communication with staff about reasons for change and improvement progress made. Of those variables with a strong relationship to quality, ones with relatively low mean ratings included workgroup coordination; sufficient resources and support for improvement; training; and efficient use of people, time, and energy. These are important areas on which management should focus to improve employee ratings of quality.

  4. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  5. The mobile image quality survey game

    Science.gov (United States)

    Rasmussen, D. René

    2012-01-01

    In this paper we discuss human assessment of the quality of photographic still images, that are degraded in various manners relative to an original, for example due to compression or noise. In particular, we examine and present results from a technique where observers view images on a mobile device, perform pairwise comparisons, identify defects in the images, and interact with the display to indicate the location of the defects. The technique measures the response time and accuracy of the responses. By posing the survey in a form similar to a game, providing performance feedback to the observer, the technique attempts to increase the engagement of the observers, and to avoid exhausting observers, a factor that is often a problem for subjective surveys. The results are compared with the known physical magnitudes of the defects and with results from similar web-based surveys. The strengths and weaknesses of the technique are discussed. Possible extensions of the technique to video quality assessment are also discussed.

  6. Joint CDRH (Center for Devices and Radiological Health) and state quality-assurance surveys in nuclear medicine: Phase 2 - radiopharmaceuticals

    International Nuclear Information System (INIS)

    Hamilton, D.R.; Evans, C.D.

    1986-08-01

    The report discusses survey results on aspects of the quality assurance of radio-pharmaceuticals from 180 nuclear-medicine facilities in the United States. Data were collected from facilities in 8 states. Demographic information about nuclear-medicine operations and quality-assurance programs was gathered by state radiation-control-program personnel. The data collected from the survey show an incomplete acceptance of quality-assurance practices for radiopharmaceuticals. Most of the facilities in the survey indicated that, because an inferior radiopharmaceutical was prepared so infrequently, they did not believe it was cost-effective to perform extensive quality-assurance testing. The Center for Devices and Radiological Health hopes that the information from the survey will stimulate nuclear-medicine professionals and their organizations to encourage appropriate testing of all radiopharmaceuticals

  7. Quality of Diabetes Care: The Challenges of an Increasing Epidemic in Mexico. Results from Two National Health Surveys (2006 and 2012)

    Science.gov (United States)

    Flores-Hernández, Sergio; Saturno-Hernández, Pedro J.; Reyes-Morales, Hortensia; Barrientos-Gutiérrez, Tonatiuh; Villalpando, Salvador; Hernández-Ávila, Mauricio

    2015-01-01

    Background The quality of diabetes care remains suboptimal according to numerous studies assessing the achievement of quality indicators for diabetes care in various healthcare settings. We report about global and specific quality indicators for diabetes care and their association to glycemic control at the population level in two national health surveys in Mexico. Methods We conducted a cross-sectional analysis of the 2006 and 2012 National Health Surveys in Mexico. We examined quality of care for 2,965 and 4,483 adults (≥ 20 years) with diagnosed type 2 diabetes using fourteen simple and two composite indicators derived from self-reported information. In a subsample for both surveys, glycated hemoglobin (HbA1c) was measured at the time of the interview. We obtained survey weight-adjusted estimators using multiple regression models (logistic and linear) with combined data files, including survey year as covariate to assess change. Results Global quality of care in 2012 was 40.8%, with a relative improvement of 11.7% between 2006 and 2012. Detections of cardiovascular disease risk factors (dyslipidemia and hypertension) were the indicators with the highest improvement, while non-pharmaceutical treatment and diabetic foot exams showed minor changes. We found a significant association between the quality of the process of diabetes care and glycemic control (OR 2.53, 95% CI 1.63-3.94). Age more than 65 years old, the type of health subsystem, gender (males), and high socio-economic status were also significantly associated to glycemic control. Conclusions Quality diabetes care and glycemic control improved and are significantly associated. However, according to international standards, the current situation remains suboptimal. A more holistic approach is needed, with an emphasis on improving quality in outpatient care. PMID:26230991

  8. Quality of Diabetes Care: The Challenges of an Increasing Epidemic in Mexico. Results from Two National Health Surveys (2006 and 2012.

    Directory of Open Access Journals (Sweden)

    Sergio Flores-Hernández

    Full Text Available The quality of diabetes care remains suboptimal according to numerous studies assessing the achievement of quality indicators for diabetes care in various healthcare settings. We report about global and specific quality indicators for diabetes care and their association to glycemic control at the population level in two national health surveys in Mexico.We conducted a cross-sectional analysis of the 2006 and 2012 National Health Surveys in Mexico. We examined quality of care for 2,965 and 4,483 adults (≥ 20 years with diagnosed type 2 diabetes using fourteen simple and two composite indicators derived from self-reported information. In a subsample for both surveys, glycated hemoglobin (HbA1c was measured at the time of the interview. We obtained survey weight-adjusted estimators using multiple regression models (logistic and linear with combined data files, including survey year as covariate to assess change.Global quality of care in 2012 was 40.8%, with a relative improvement of 11.7% between 2006 and 2012. Detections of cardiovascular disease risk factors (dyslipidemia and hypertension were the indicators with the highest improvement, while non-pharmaceutical treatment and diabetic foot exams showed minor changes. We found a significant association between the quality of the process of diabetes care and glycemic control (OR 2.53, 95% CI 1.63-3.94. Age more than 65 years old, the type of health subsystem, gender (males, and high socio-economic status were also significantly associated to glycemic control.Quality diabetes care and glycemic control improved and are significantly associated. However, according to international standards, the current situation remains suboptimal. A more holistic approach is needed, with an emphasis on improving quality in outpatient care.

  9. Indicators to examine quality of large scale survey data: an example through district level household and facility survey.

    Directory of Open Access Journals (Sweden)

    Kakoli Borkotoky

    Full Text Available BACKGROUND: Large scale surveys are the main source of data pertaining to all the social and demographic indicators, hence its quality is also of great concern. In this paper, we discuss the indicators used to examine the quality of data. We focus on age misreporting, incompleteness and inconsistency of information; and skipping of questions on reproductive and sexual health related issues. In order to observe the practical consequences of errors in a survey; the District Level Household and Facility Survey (DLHS-3 is used as an example dataset. METHODS: Whipple's and Myer's indices are used to identify age misreporting. Age displacements are identified by estimating downward and upward transfers for women from bordering age groups of the eligible age range. Skipping pattern is examined by recording the responses to the questions which precede the sections on birth history, immunization, and reproductive and sexual health. RESULTS: The study observed errors in age reporting, in all the states, but the extent of misreporting differs by state and individual characteristics. Illiteracy, rural residence and poor economic condition are the major factors that lead to age misreporting. Female were excluded from the eligible age group, to reduce the duration of interview. The study further observed that respondents tend to skip questions on HIV/RTI and other questions which follow a set of questions. CONCLUSION: The study concludes that age misreporting, inconsistency and incomplete response are three sources of error that need to be considered carefully before drawing conclusions from any survey. DLHS-3 also suffers from age misreporting, particularly for female in the reproductive ages. In view of the coverage of the survey, it may not be possible to control age misreporting completely, but some extra effort to probe a better answer may help in improving the quality of data in the survey.

  10. The 14th quality control survey for radioisotope in vitro tests in Japan, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This report presents the results of the 14th quality control nationwide survey. Of 490 facilities performing RI in vitro tests as of December 1992, 261 (53.3%) participated in the present 1992 survey. Free testosterone and renin were added to the following conventional 37 test items: adrenocorticotropic hormone (ACTH), growth hormone (GH), somatomedin C, follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin, thyroid stimulating hormone (TSH), triiodothyronine (T[sub 3]), free T[sub 3], thyroxine (T[sub 4]), free T[sub 4], T[sub 3] uptake, thyroglobulin, T[sub 3] binding globulin (TBG), parathyroid hormone (PTH), calcitonin, insulin, C-peptide, glucagon, gastrin, testosterone, estradiol, progesterone, 17[alpha]-hydroxyprogesterone, aldosterone, cortisol, immunoglobulin E (IgE), digoxin, [alpha]-fetoprotein, carcinoembryonic antigen (CEA), tissue polypeptide antigen (TPA), CA125, CA19-9, CA15-3, prostatic acid phosphatase (PAP), [beta][sub 2]-microglobulin, and ferritin. Measurement data for each kit were analyzed by a mean value of measurements, standard deviation, and coefficient of variation (CV). Both 'within kit variation' between facilities and 'between kit variation' showed a CV of 20% or less for GH, somatomedin C, TSH, T[sub 3], T[sub 4], T[sub 3] uptake, TBG, cortisol, IgE, CA125, PAP, and [beta][sub 2]-microglobulin, revealing satisfactory results. There was a great 'within kit variation' between facilities in ACTH, free T[sub 4], and calcitonin; and there was a great 'between kit variation' in ACTH, LH, free T[sub 4], thyroglobulin, PTH, calcitonin, and [alpha]-fetoprotein. (N.K.).

  11. Anesthesia Quality and Patient Safety in China: A Survey.

    Science.gov (United States)

    Zhu, Bin; Gao, Huan; Zhou, Xiangyong; Huang, Jeffrey

    There has been no nationwide investigation into anesthesia quality and patient safety in China. The authors surveyed Chinese anesthesiologists about anesthesia quality by sending a survey to all anesthesiologist members of the New Youth Anesthesia Forum via WeChat. The respondents could choose to use a mobile device or desktop to complete the survey. The overall response rate was 43%. Intraoperative monitoring: 77.9% of respondents reported that electrocardiogram monitoring was routinely applied for all patients; only 55% of the respondents reported that they routinely used end-tidal carbon dioxide monitoring for their patients under general anesthesia. 10.3% of respondents admitted that they had at least one wrong medicine administration in the past 3 months; 12.4% reported that they had at least one case of cardiac arrest in the past year. This is the first anesthesia quality survey in China. The findings revealed potential anesthesia safety issues in China.

  12. 2006 B100 Quality Survey Results: Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Alleman, T. L.; McCormick, R. L.; Deutch, S.

    2007-05-01

    In 2006, the National Renewable Energy Laboratory conducted a nationwide quality survey of pure biodiesel (B100) intended to be used as a blendstock. The study collected random samples throughout the United States and analyzed them for quality against the current and proposed ASTM D6751 fuel quality specifications.

  13. Field methods and quality-assurance plan for water-quality activities and water-level measurements, U.S. Geological Survey, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Bartholomay, Roy C.; Maimer, Neil V.; Wehnke, Amy J.

    2014-01-01

    Water-quality activities and water-level measurements by the personnel of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation’s water resources. The activities are carried out in cooperation with the U.S. Department of Energy (DOE) Idaho Operations Office. Results of the water-quality and hydraulic head investigations are presented in various USGS publications or in refereed scientific journals and the data are stored in the National Water Information System (NWIS) database. The results of the studies are used by researchers, regulatory and managerial agencies, and interested civic groups. In the broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the “state-of-the-art” technology, and quality assurance ensures that quality control is maintained within specified limits.

  14. Quality assurance and halal control points for the food industry

    OpenAIRE

    Lau, An Nee; Jamaludin, Mohd Hafiz; Soon, Jan Mei

    2016-01-01

    Purpose\\ud To determine the understanding of halal concept among food production workers and to develop a generic Halal Control Point (HCP) Plan for the manufacturing of processed foods.\\ud \\ud Design/methodology/approach\\ud A mixed method (interviews, surveys and microbiological analyses) approach was used to analyze the hygiene and halal practices of four food processing plants in Penang, Malaysia. Two hundred food production workers were surveyed (and quality assurance staff were interview...

  15. Implementation of Quality Control Protocol in Mammography: A Serbian Experience

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Kosutic, D.; Arandjic, D.; Kovacevic, M.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. In Serbia, mammography is performed only clinically, although there is a long term plan to introduce mammography as screening method. Currently there are 60 mammography units in practice in Serbia, resulting with 70 000 mammographies annually. The purpose of this paper is preliminary evaluation of the mammography practice in Serbia, having in mind the annual number of examinations and fact that part of examination is performed on women without any clinical signs. For pilot implementation of Quality Control (QC) protocol in mammography, five hospitals with highest workload have been selected, representing the typical mammography practice in Serbia. Developed QC protocol, based on European guidelines for quality assurance in breast cancer screening and diagnosis, actual practice and resources, includes equipment testing and maintenance, staff training and QC management and allocation of responsibilities. Subsequently, it should be applied on the national scale. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Main problems were associated with film processing, viewing conditions and optical density control. The preliminary survey of mammography practice highlighted the need for optimization of radiation protection and training of operating staff, although the survey itself was very valuable learning process for all participants. Furthermore, systematic implementation of QC protocol should provide reliable performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practical.(author)

  16. A Systematic Analysis of Quality of Teaching Surveys

    OpenAIRE

    Martin Davies; Joe Hirschberg; Jenny Lye; Carol Johnston

    2008-01-01

    All tertiary institutions in Australia use the same Course Evaluation Questionnaire (CEQ) however for the internal evaluation of teaching they use their own surveys. This paper performs an analysis of the internal Quality of Teaching Surveys (QTS) used in Australian Universities. We classify the questions within the QTS surveys. This classification is used to explore how different universities’ surveys are similar to each other. We find that some universities use a QTS that is quite distinct ...

  17. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  18. Astro-WISE for KiDS survey production and quality control

    NARCIS (Netherlands)

    Kleijn, G.V.; de Jong, Jelte; Valentijn, E.; Kuijken, K.; Consortiums, KiDS; Consortium, Astro-WISE; Ballester, P.; Egret, D.; Lorente, N.P.F.

    The Kilo Degree Survey (KiDS) is a 1500 square degree optical imaging survey with the recently commissioned OmegaCAM wide-field imager on the VLT Survey Telescope (VST). A suite of data products will be delivered to ESO and the community by the KiDS survey team. Spread over Europe, the KiDS team

  19. Software for creating quality control database in diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Spassov, G.; Tabakov, S.

    2000-01-01

    The paper describes a PC based program with database for quality control (QC). It keeps information about all surveyed equipment and measured parameters. The first function of the program is to extract information from old (existing) MS Excel spreadsheets with QC surveys. The second function is used for input of measurements which are automatically organized in MS Excel spreadsheets and built into the database. The spreadsheets are based on the protocols described in the EMERALD Training Scheme. In addition, the program can make statistics of all measured parameters, both in absolute term and in time

  20. National survey provides average power quality profiles for different customer groups

    International Nuclear Information System (INIS)

    Hughes, B.; Chan, J.

    1996-01-01

    A three year survey, beginning in 1991, was conducted by the Canadian Electrical Association to study the levels of power quality that exist in Canada, and to determine ways to increase utility expertise in making power quality measurements. Twenty-two utilities across Canada were involved, with a total of 550 sites being monitored, including residential and commercial customers. Power disturbances, power outages and power quality were recorded for each site. To create a group average power quality plot, the transient disturbance activity for each site was normalized to a per channel, per month basis and then divided into a grid. Results showed that the average power quality provided by Canadian utilities was very good. Almost all the electrical disturbance within a customer premises were created and stayed within those premises. Disturbances were generally beyond utility control. Utilities could, however, reduce the amount of time the steady-state voltage exceeds the CSA normal voltage upper limit. 5 figs

  1. A New Dual-purpose Quality Control Dosimetry Protocol for Diagnostic Reference-level Determination in Computed Tomography.

    Science.gov (United States)

    Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh

    2018-05-17

    A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).

  2. Quality Management: Survey of Federal Organizations

    Science.gov (United States)

    1992-10-01

    Deming, Armand Feigenbaum, Kaoru Ishikawa , and J. M. Juran. For purposes of our survey, quality improvement efforts which have the same basic goals and...Feigenbaum, Kaoru Ishikawa , and J.M. Juran. Even though this approach may have different names, it most often includes the following five concepts

  3. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  4. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  5. Global review of health care surveys using lot quality assurance sampling (LQAS), 1984-2004.

    Science.gov (United States)

    Robertson, Susan E; Valadez, Joseph J

    2006-09-01

    We conducted a global review on the use of lot quality assurance sampling (LQAS) to assess health care services, health behaviors, and disease burden. Publications and reports on LQAS surveys were sought from Medline and five other electronic databases; the World Health Organization; the World Bank; governments, nongovernmental organizations, and individual scientists. We identified a total of 805 LQAS surveys conducted by different management groups during January 1984 through December 2004. There was a striking increase in the annual number of LQAS surveys conducted in 2000-2004 (128/year) compared with 1984-1999 (10/year). Surveys were conducted in 55 countries, and in 12 of these countries there were 10 or more LQAS surveys. Geographically, 317 surveys (39.4%) were conducted in Africa, 197 (28.5%) in the Americas, 115 (14.3%) in the Eastern Mediterranean, 114 (14.2%) in South-East Asia, 48 (6.0%) in Europe, and 14 (1.8%) in the Western Pacific. Health care parameters varied, and some surveys assessed more than one parameter. There were 320 surveys about risk factors for HIV/AIDS/sexually transmitted infections; 266 surveys on immunization coverage, 240 surveys post-disasters, 224 surveys on women's health, 142 surveys on growth and nutrition, 136 surveys on diarrheal disease control, and 88 surveys on quality management. LQAS surveys to assess disease burden included 23 neonatal tetanus mortality surveys and 12 surveys on other diseases. LQAS is a practical field method which increasingly is being applied in assessment of preventive and curative health services, and may offer new research opportunities to social scientists. When LQAS data are collected recurrently at multiple time points, they can be used to measure the spatial variation in behavior change. Such data provide insight into understanding relationships between various investments in social, human, and physical capital, and into the effectiveness of different public health strategies in achieving

  6. Survey of Equipment Quality Control in Radiotherapy Centers in Croatia: First Results

    International Nuclear Information System (INIS)

    Jurkovic, S.; Diklic, A.; Smilovic Radojcic, Dj.; Svabic, M.; Kasabasic, M.; Ivkovic, A.; Faj, D.

    2011-01-01

    Implementation of advanced radiation therapy techniques into clinical practice has a huge influence on tumour control as well as normal tissue sparing. Introduction of Conformal Radiation Therapy (CRT) and Intensity Modulated Radiation Therapy (IMRT) into clinical practice results in precise 'tailoring' of dose distributions and according to that in reduction of irradiated volumes. This is not possible without, for the application of advanced radiation therapy techniques constructed, linear accelerators. They must be very precise, well tuned and maintained. In this way the milestone of radiation therapy quality assurance programme is machine quality control (QC). First step in development of quality control programme is existence of written QC protocols. The survey of existence of written QC protocols showed the lack of written protocols for QC procedures in Croatian radiotherapy departments. In this way regular implementation of the procedures are usually left to the conscience of the medical physicists. In the IAEA granted projects CRO6008 and RER9093, we harmonized existing QC protocols between radiation therapy departments at University hospitals Rijeka and Osijek and developed the new ones. The protocols made according to international guidelines are publicly available at websites of the State Office for Radiological and Nuclear Safety and Croatian medical physics society in order to help other radiotherapy departments in Croatia to develop their own ones. Next step was reviewing of QC practices in different centres and exchanging experiences. For that purpose we defined a set of tests, according to the existing QC protocols. Then, on-site measurements were done to check QC parameters of linear accelerators and simulators in six radiation therapy centres in Croatia. In this paper we present the tests preformed, devices and analysing tools used, along with the overall results. Tests were preformed in six radiotherapy centres in Croatia on nine linear

  7. Quality control of intelligence research

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  8. Interaction between production control and quality control

    NARCIS (Netherlands)

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  9. Quality control in radiotherapy

    International Nuclear Information System (INIS)

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  10. Tools for Real-Time Control Systems Co-Design - A Survey

    OpenAIRE

    Henriksson, Dan; El-Khoury, Jad; Årzén, Karl-Erik; Törngren, Martin; Redell, Ola

    2005-01-01

    This report presents a survey of current simulation tools in the area of integrated control and real-time systems design. Each tool is presented with a quick overview followed by a more detailed section describing comparative aspects of the tool. These aspects describe the context and purpose of the tool (scenarios, development stages, activities, and qualities/constraints being addressed) and the actual tool technology (tool architecture, inputs, outputs, modeling content, extensibility and ...

  11. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  12. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  13. Nuclear Medicine Technologists' Perception and Current Assessment of Quality: A Society of Nuclear Medicine and Molecular Imaging Technologist Section Survey.

    Science.gov (United States)

    Mann, April; Farrell, Mary Beth; Williams, Jessica; Basso, Danny

    2017-06-01

    In 2015, the Society of Nuclear Medicine and Molecular Imaging Technologist Section (SNMMI-TS) launched a multiyear quality initiative to help prepare the technologist workforce for an evidence-based health-care delivery system that focuses on quality. To best implement the quality strategy, the SNMMI-TS first surveyed technologists to ascertain their perception of quality and current measurement of quality indicators. Methods: An internet survey was sent to 27,989 e-mail contacts. Questions related to demographic data, perceptions of quality, quality measurement, and opinions on the minimum level of education are discussed in this article. Results: A total of 4,007 (14.3%) responses were received. When asked to list 3 words or phrases that represent quality, there were a plethora of different responses. The top 3 responses were image quality, quality control, and technologist education or competency. Surveying patient satisfaction was the most common quality measure (80.9%), followed by evaluation of image quality (78.2%). Evaluation of image quality (90.3%) and equipment functionality (89.4%) were considered the most effective measures. Technologists' differentiation between quality, quality improvement, quality control, quality assurance, and quality assessment seemed ambiguous. Respondents were confident in their ability to assess and improve quality at their workplace (91.9%) and agreed their colleagues were committed to delivering quality work. Of note, 70.7% of respondents believed that quality is directly related to the technologist's level of education. Correspondingly, respondents felt there should be a minimum level of education (99.5%) and that certification or registry should be required (74.4%). Most respondents (59.6%) felt that a Bachelor's degree should be the minimum level of education, followed by an Associate's degree (40.4%). Conclusion: To best help nuclear medicine technologists provide quality care, the SNMMI-TS queried technologists to

  14. Quantum control theory and applications: A survey

    OpenAIRE

    Dong, Daoyi; Petersen, Ian R

    2009-01-01

    This paper presents a survey on quantum control theory and applications from a control systems perspective. Some of the basic concepts and main developments (including open-loop control and closed-loop control) in quantum control theory are reviewed. In the area of open-loop quantum control, the paper surveys the notion of controllability for quantum systems and presents several control design strategies including optimal control, Lyapunov-based methodologies, variable structure control and q...

  15. Bias in patient satisfaction surveys: a threat to measuring healthcare quality.

    Science.gov (United States)

    Dunsch, Felipe; Evans, David K; Macis, Mario; Wang, Qiao

    2018-01-01

    Patient satisfaction surveys are an increasingly common element of efforts to evaluate the quality of healthcare. Many patient satisfaction surveys in low/middle-income countries frame statements positively and invite patients to agree or disagree, so that positive responses may reflect either true satisfaction or bias induced by the positive framing. In an experiment with more than 2200 patients in Nigeria, we distinguish between actual satisfaction and survey biases. Patients randomly assigned to receive negatively framed statements expressed significantly lower levels of satisfaction (87%) than patients receiving the standard positively framed statements (95%-pquality of health services. Providers and policymakers wishing to gauge the quality of care will need to avoid framing that induces bias and to complement patient satisfaction measures with more objective measures of quality.

  16. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  17. Water Quality attainment Information from Clean Water Act Statewide Statistical Surveys

    Data.gov (United States)

    U.S. Environmental Protection Agency — Designated uses assessed by statewide statistical surveys and their state and national attainment categories. Statewide statistical surveys are water quality...

  18. Water Quality Stressor Information from Clean Water Act Statewide Statistical Surveys

    Data.gov (United States)

    U.S. Environmental Protection Agency — Stressors assessed by statewide statistical surveys and their state and national attainment categories. Statewide statistical surveys are water quality assessments...

  19. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  20. An algorithm to assess methodological quality of nutrition and mortality cross-sectional surveys: development and application to surveys conducted in Darfur, Sudan.

    Science.gov (United States)

    Prudhon, Claudine; de Radiguès, Xavier; Dale, Nancy; Checchi, Francesco

    2011-11-09

    Nutrition and mortality surveys are the main tools whereby evidence on the health status of populations affected by disasters and armed conflict is quantified and monitored over time. Several reviews have consistently revealed a lack of rigor in many surveys. We describe an algorithm for analyzing nutritional and mortality survey reports to identify a comprehensive range of errors that may result in sampling, response, or measurement biases and score quality. We apply the algorithm to surveys conducted in Darfur, Sudan. We developed an algorithm based on internationally agreed upon methods and best practices. Penalties are attributed for a list of errors, and an overall score is built from the summation of penalties accrued by the survey as a whole. To test the algorithm reproducibility, it was independently applied by three raters on 30 randomly selected survey reports. The algorithm was further applied to more than 100 surveys conducted in Darfur, Sudan. The Intra Class Correlation coefficient was 0.79 for mortality surveys and 0.78 for nutrition surveys. The overall median quality score and range of about 100 surveys conducted in Darfur were 0.60 (0.12-0.93) and 0.675 (0.23-0.86) for mortality and nutrition surveys, respectively. They varied between the organizations conducting the surveys, with no major trend over time. Our study suggests that it is possible to systematically assess quality of surveys and reveals considerable problems with the quality of nutritional and particularly mortality surveys conducted in the Darfur crisis.

  1. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  2. Lot quality assurance sampling techniques in health surveys in developing countries: advantages and current constraints.

    Science.gov (United States)

    Lanata, C F; Black, R E

    1991-01-01

    Traditional survey methods, which are generally costly and time-consuming, usually provide information at the regional or national level only. The utilization of lot quality assurance sampling (LQAS) methodology, developed in industry for quality control, makes it possible to use small sample sizes when conducting surveys in small geographical or population-based areas (lots). This article describes the practical use of LQAS for conducting health surveys to monitor health programmes in developing countries. Following a brief description of the method, the article explains how to build a sample frame and conduct the sampling to apply LQAS under field conditions. A detailed description of the procedure for selecting a sampling unit to monitor the health programme and a sample size is given. The sampling schemes utilizing LQAS applicable to health surveys, such as simple- and double-sampling schemes, are discussed. The interpretation of the survey results and the planning of subsequent rounds of LQAS surveys are also discussed. When describing the applicability of LQAS in health surveys in developing countries, the article considers current limitations for its use by health planners in charge of health programmes, and suggests ways to overcome these limitations through future research. It is hoped that with increasing attention being given to industrial sampling plans in general, and LQAS in particular, their utilization to monitor health programmes will provide health planners in developing countries with powerful techniques to help them achieve their health programme targets.

  3. 48 CFR 53.301-1406 - Preaward Survey of Prospective Contractor-Quality Assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Preaward Survey of Prospective Contractor-Quality Assurance. 53.301-1406 Section 53.301-1406 Federal Acquisition Regulations...-1406 Preaward Survey of Prospective Contractor—Quality Assurance. ER09DE97.000 ER09DE97.001 [62 FR...

  4. PDA survey of quality risk management practices in the pharmaceutical, devices, & biotechnology industries.

    Science.gov (United States)

    Ahmed, Ruhi; Baseman, Harold; Ferreira, Jorge; Genova, Thomas; Harclerode, William; Hartman, Jeffery; Kim, Samuel; Londeree, Nanette; Long, Michael; Miele, William; Ramjit, Timothy; Raschiatore, Marlene; Tomonto, Charles

    2008-01-01

    In July 2006 the Parenteral Drug Association's Risk Management Task Force for Aseptic Processes, conducted an electronic survey of PDA members to determine current industry practices regarding implementation of Quality Risk Management in their organizations. This electronic survey was open and publicly available via the PDA website and targeted professionals in our industry who are involved in initiating, implementing, or reviewing risk management programs or decisions in their organizations. One hundred twenty-nine members participated and their demographics are presented in the sidebar "Correspondents Profile". Among the major findings are: *The "Aseptic Processing/Filling" operation is the functional area identified as having the greatest need for risk assessment and quality risk management. *The most widely used methodology in industry to identify risk is Failure Mode and Effects Analysis (FMEA). This tool was most widely applied in assessing change control and for adverse event, complaint, or failure investigations. *Despite the fact that personnel training was identified as the strategy most used for controlling/minimizing risk, the largest contributors to sterility failure in operations are still "Personnel". *Most companies still rely on "Manufacturing Controls" to mitigate risk and deemed the utilization of Process Analytical Technology (PAT) least important in this aspect. *A majority of correspondents verified that they did not periodically assess their risk management programs. *A majority of the correspondents desired to see case studies or examples of risk analysis implementation (as applicable to aseptic processing) in future PDA technical reports on risk management.

  5. Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.

    Science.gov (United States)

    Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul

    2014-06-01

    While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  6. Survey of licensee control room habitability practices

    International Nuclear Information System (INIS)

    Boland, J.F.; Brookshire, R.L.; Danielson, W.F.; Driscoll, J.W.; Graham, E.D.; McConnell, R.J.; Thompson, V.N.

    1985-04-01

    This document presents the results of a survey of Licensee control-room-habitability practices. The survey is part of a comprehensive program plan instituted in August 1983 by the NRC to respond to ongoing questions from the Advisory Committee on Reactor Safeguards (ACRS). The emphasis of this survey was to determine by field review the control-room habitability practices at three different plants, one of which is still under construction and scheduled to receive an operating license in 1986. The other two plants are currently operating, having received operating licenses in the mid-1970's and early 1980's. The major finding of this survey is that despite the fact that the latest control-room-habitability systems have become larger and more complex than earlier systems surveyed, the latest systems do not appear to be functionally superior. The major recommendation of this report is to consolidate into a single NRC document, based upon a comprehensive systems engineering approach, the pertinent criteria for control-room-habitability design

  7. Potential of integrated continuous surveys and quality management to support monitoring, evaluation, and the scale-up of health interventions in developing countries.

    Science.gov (United States)

    Rowe, Alexander K

    2009-06-01

    Well-funded initiatives are challenging developing countries to increase health intervention coverage and show impact. Despite substantial resources, however, major obstacles include weak health systems, a lack of reasonably accurate monitoring data, and inadequate use of data for managing programs. This report discusses how integrated continuous surveys and quality management (I-Q), which are well-recognized approaches in wealthy countries, could support intervention scale-up, monitoring and evaluation, quality control for commodities, capacity building, and implementation research in low-resource settings. Integrated continuous surveys are similar to existing national cross-sectional surveys of households and health facilities, except data are collected over several years by permanent teams, and most results are reported monthly at the national, province, and district levels. Quality management involves conceptualizing work as processes, involving all workers in quality improvement, monitoring quality, and teams that improve quality with "plan-do-study-act" cycles. Implementing and evaluating I-Q in a low-income country would provide critical information on the value of this approach.

  8. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  9. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  10. Relationship Between Hospital Performance on a Patient Satisfaction Survey and Surgical Quality.

    Science.gov (United States)

    Sacks, Greg D; Lawson, Elise H; Dawes, Aaron J; Russell, Marcia M; Maggard-Gibbons, Melinda; Zingmond, David S; Ko, Clifford Y

    2015-09-01

    The Centers for Medicare and Medicaid Services include patient experience as a core component of its Value-Based Purchasing program, which ties financial incentives to hospital performance on a range of quality measures. However, it remains unclear whether patient satisfaction is an accurate marker of high-quality surgical care. To determine whether hospital performance on a patient satisfaction survey is associated with objective measures of surgical quality. Retrospective observational study of participating American College of Surgeons National Surgical Quality Improvement Project (ACS NSQIP) hospitals. We used data from a linked database of Medicare inpatient claims, ACS NSQIP, the American Hospital Association annual survey, and Hospital Compare from December 2, 2004, through December 31, 2008. A total of 103 866 patients older than 65 years undergoing inpatient surgery were included. Hospitals were grouped by quartile based on their performance on the Hospital Consumer Assessment of Healthcare Providers and Systems survey. Controlling for preoperative risk factors, we created hierarchical logistic regression models to predict the occurrence of adverse postoperative outcomes based on a hospital's patient satisfaction scores. Thirty-day postoperative mortality, major and minor complications, failure to rescue, and hospital readmission. Of the 180 hospitals, the overall mean patient satisfaction score was 68.0% (first quartile mean, 58.7%; fourth quartile mean, 76.7%). Compared with patients treated at hospitals in the lowest quartile, those at the highest quartile had significantly lower risk-adjusted odds of death (odds ratio = 0.85; 95% CI, 0.73-0.99), failure to rescue (odds ratio = 0.82; 95% CI, 0.70-0.96), and minor complication (odds ratio = 0.87; 95% CI, 0.75-0.99). This translated to relative risk reductions of 11.1% (P = .04), 12.6% (P = .02), and 11.5% (P = .04), respectively. No significant relationship was noted between patient satisfaction

  11. The data quality analyzer: a quality control program for seismic data

    Science.gov (United States)

    Ringler, Adam; Hagerty, M.T.; Holland, James F.; Gonzales, A.; Gee, Lind S.; Edwards, J.D.; Wilson, David; Baker, Adam

    2015-01-01

    The U.S. Geological Survey's Albuquerque Seismological Laboratory (ASL) has several initiatives underway to enhance and track the quality of data produced from ASL seismic stations and to improve communication about data problems to the user community. The Data Quality Analyzer (DQA) is one such development and is designed to characterize seismic station data quality in a quantitative and automated manner.

  12. Commercial jet fuel quality control

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  13. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  14. MVMA's 1991 summer gasoline survey and air quality

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In a previous newsletter (September 1991 issue of this journal), the results of MVMA's 1990 Summer Gasoline Survey were discussed. It was noted that many gasolines containing high concentrations of olefins (over 15 percent volume) were being marketed in the northeast corridor between Washington, D.C. and Boston. Also noted was the finding that the composition of gasoline plays an important role in determining the emissions from vehicles on the road. In this newsletter, the potential effects on air quality of the more recently surveyed gasolines are discussed. Three grades of unleaded gasoline were covered in the survey (premium, intermediate, and regular). 1 tab

  15. An algorithm to assess methodological quality of nutrition and mortality cross-sectional surveys: development and application to surveys conducted in Darfur, Sudan

    Directory of Open Access Journals (Sweden)

    Prudhon Claudine

    2011-11-01

    Full Text Available Abstract Background Nutrition and mortality surveys are the main tools whereby evidence on the health status of populations affected by disasters and armed conflict is quantified and monitored over time. Several reviews have consistently revealed a lack of rigor in many surveys. We describe an algorithm for analyzing nutritional and mortality survey reports to identify a comprehensive range of errors that may result in sampling, response, or measurement biases and score quality. We apply the algorithm to surveys conducted in Darfur, Sudan. Methods We developed an algorithm based on internationally agreed upon methods and best practices. Penalties are attributed for a list of errors, and an overall score is built from the summation of penalties accrued by the survey as a whole. To test the algorithm reproducibility, it was independently applied by three raters on 30 randomly selected survey reports. The algorithm was further applied to more than 100 surveys conducted in Darfur, Sudan. Results The Intra Class Correlation coefficient was 0.79 for mortality surveys and 0.78 for nutrition surveys. The overall median quality score and range of about 100 surveys conducted in Darfur were 0.60 (0.12-0.93 and 0.675 (0.23-0.86 for mortality and nutrition surveys, respectively. They varied between the organizations conducting the surveys, with no major trend over time. Conclusion Our study suggests that it is possible to systematically assess quality of surveys and reveals considerable problems with the quality of nutritional and particularly mortality surveys conducted in the Darfur crisis.

  16. Survey of mammography practice in Croatia: Equipment performance, image quality and dose

    International Nuclear Information System (INIS)

    Faj, D.; Stimac, D.; Ivezic, Z.; Kasabasic, M.; Ivkovic, A.; Posedel, D.; Kubelka, D.; Ilakovac, V.; Brnic, Z.; Bjelac, O.C.

    2008-01-01

    A national audit of mammography equipment performance, image quality and dose has been conducted in Croatia. Film-processing parameters, optical density (OD), average glandular dose (AGD) to the standard breast, viewing conditions and image quality were examined using TOR(MAM) test object. Average film gradient ranged from 2.6 to 3.7, with a mean of 3.1. Tube voltage used for imaging of the standard 45 mm polymethylmethacrylate phantom ranged from 24 to 34 kV, and OD ranged from 0.75 to 1.94 with a mean of 1.26. AGD to the standard breast ranged from 0.4 to 2.3 mGy with a mean of 1.1 mGy. Besides clinical conditions, the authors have imaged the standard phantom in the referent conditions with 28 kV and OD as close as possible to 1.5. Then, AGD ranged from 0.5 to 2.6 mGy with a mean of 1.3 mGy. Image viewing conditions were generally unsatisfying with ambient light up to 500 lx and most of the viewing boxes with luminance between 1000 and 2000 cd per m 2 . TOR(MAM) scoring of images taken in clinical and referent conditions was done by local radiologists in local image viewing conditions and by the referent radiologist in good image viewing conditions. Importance of OD and image viewing conditions for diagnostic information were analysed. The survey showed that the main problem in Croatia is the lack of written quality assurance/quality control (QA/QC) procedures. Consequently, equipment performance, image quality and dose are unstable and activities to improve image quality or to reduce the dose are not evidence-based. This survey also had an educational purpose, introducing in Croatia the QC based on European Commission Guidelines. (authors)

  17. Internal Quality Control Practices in Coagulation Laboratories: recommendations based on a patterns-of-practice survey.

    Science.gov (United States)

    McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R

    2015-12-01

    Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.

  18. Quality-of-life survey for patients diagnosed with nonmuscle-invasive bladder cancer.

    Science.gov (United States)

    Abáigar-Pedraza, I; Megías-Garrigós, J; Sánchez-Payá, J

    2016-05-01

    To determine the reliability and validity of a quality-of-life survey for patients with nonmuscle-invasive bladder cancer. A total of 180 patients were included in the study. We developed a survey with 21 questions grouped into 5 areas. The patients filled in this survey and the Functional Assessment of Cancer Therapy - Bladder Cancer (FACT-BL) survey. To assess reliability, we calculated Cronbach's alpha coefficient and the kappa index. To determine criterion validity, we studied the association between the scores obtained from our survey and those from the FACT-BL survey using the Pearson correlation coefficient. To determine the construct validity (factorial and discriminatory), we performed a factor analysis, comparing it with Student's t-test for the scores obtained according to the tumour characteristics of reduced quality of life (e.g., malignancies located at the trigone of the bladder). Cronbach's alpha reliability coefficient was .83, and the kappa index varied between .7 and 1. For the association study between the new survey and the FACT-BL survey, we measured an r=.82 for the overall score and between r=.68 (disease) and r=.97 (sex life) in the various measures. In the factor analysis, we measured a Kaiser-Meyer-Olkin index of .77 and performed the Barlett test (P<.001). The comparison between the scores, in the presence or absence of certain tumour characteristics, has shown a reduced quality of life when those characteristics are present, which was statistically significant (P<.05) in the majority of cases. Our survey to measure the quality of life of patients with nonmuscle-invasive bladder cancer is reliable and valid. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  20. ARM User Survey Report: Data Access, Quality, and Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Mather, JH; Roeder, LR; Sivaraman, C

    2012-06-28

    The objective of this survey was to obtain user feedback to determine how users of the Atmospheric Radiation Measurement (ARM) Climate Research Facility Data Archive interact with the more than 2000 available types of datastreams. The survey also gathered information about data discovery and data quality. The Market and Competitive Analysis group at Pacific Northwest National Laboratory worked with web administrators to develop a landing page from which users could access the survey. A survey invitation was sent by ARM via email to about 6100 users on February 22, 2012. The invitation was also posted on the ARM website and Facebook page. Reminders were sent via e-mail and posted on Facebook while the survey was open, February 22-March 23, 2012.

  1. The importance of standardized observations to evaluate nutritional care quality in the survey process.

    Science.gov (United States)

    Schnelle, John F; Bertrand, Rosanna; Hurd, Donna; White, Alan; Squires, David; Feuerberg, Marvin; Hickey, Kelly; Simmons, Sandra F

    2009-10-01

    Guidelines written for government surveyors who assess nursing home (NH) compliance with federal standards contain instructions to observe the quality of mealtime assistance. However, these instructions are vague and no protocol is provided for surveyors to record observational data. This study compared government survey staff observations of mealtime assistance quality to observations by research staff using a standardized protocol that met basic standards for accurate behavioral measurement. Survey staff used either the observation instructions in the standard survey process or those written for the revised Quality Improvement Survey (QIS). Trained research staff observed mealtime care in 20 NHs in 5 states during the same time period that survey staff evaluated care in the same facilities, although it could not be determined if survey and research staff observed the same residents during the same meals. Ten NHs were evaluated by government surveyors using the QIS survey instructions and 10 NHs were evaluated by surveyors using the standard survey instructions. Research staff observations using a standardized observation protocol identified a higher proportion of residents receiving inadequate feeding assistance during meals relative to survey staff using either the standard or QIS survey instructions. For example, more than 50% of the residents who ate less than half of their meals based on research staff observation were not offered an alternative to the served meal, and the lack of alternatives, or meal substitutions, was common in all 20 NHs. In comparison, the QIS survey teams documented only 2 instances when meal substitutes were not offered in 10 NHs and the standard survey teams documented no instances in 10 NHs. Standardized mealtime observations by research staff revealed feeding assistance care quality issues in all 20 study NHs. Surveyors following the instructions in either the standard or revised QIS surveys did not detect most of these care quality

  2. Survey procedure: Control and accountability of nuclear materials

    International Nuclear Information System (INIS)

    Van Ness, H.

    1987-02-01

    This procedure outlines the method by which the Department of Energy (DOE) San Francisco Operations Office (SAN) will plan and execute periodic field surveys of the Material Control and Accountability (MC and A) program and practices at designated contractors' facilities. The surveys will be conducted in accordance with DOE Order 5630.7, Control and Accountability of Nuclear Materials Surveys (7/8/81) to ascertain compliance with applicable DOE Orders and SAN Management Directives in the 5630 series, as well as the adequacy of the contractor's program and procedures. Surveys will be conducted by the Safeguards and Security Division of DOE-SAN. The survey team will review and evaluate the adequacy of the contractor's procedures and practices for nuclear material control and accounting by means of physical inventory, internal control, measurement and statistics, material control indicators, records and reports, and personnel training. The survey will include an audit of records and reports, observation of inventory procedures, an independent test of the inventory and a review and evaluation of the inventory differences, accidental losses, and normal operational losses as applicable to the facility to be surveyed

  3. Survey of potential use of dynamic line phantom for quality control of Gamma camera

    International Nuclear Information System (INIS)

    Trindev, P.; Ozturk, N.

    2004-01-01

    Different phantoms, used to evaluate the essential for image quality parameters of gamma cameras in order to avoid artefacts, are presented. The prices are significant and it is a sensible approach to optimise the type and number of phantoms necessary for quality control. Among all phantoms the price of 'Dynamic Line Phantom' (DLP) is impressive, but it is announced to substitute several 'passive' and 'active' phantoms. The goal of this paper is to justify this statement. The programs, based on image profile are discussed in the paper and the practical uses of the different programs are given

  4. Quality assurance in individual monitoring: A summary of the EURADOS survey 2012

    International Nuclear Information System (INIS)

    Gilvin, P.; Alves, J.G.; Cherestes, C.; Dijk, J.W.E. van; Lehtinen, M.; Rossi, F.; Vekic, B.

    2014-01-01

    EURADOS Working Group 2 (WG2) on Harmonization of Individual Monitoring is a network of individual monitoring services (IMSs) that aims to promote quality, technical excellence and good practice in European Member States. To help to improve quality, in 2012 EURADOS WG2 carried out a survey of IMSs in Europe. The survey was sent to about 170 IMS and included questions on: the use of formal quality assurance (QA) standards, QA in dosimetry, matters of practice, and common sources of error. The present paper summarises the main findings of the survey, and compares them with those of an earlier study (2003). The survey found that profile of QA is high amongst the responding IMSs, and that most are following good practice. A majority of services comply with formal quality standards and good attention is paid to traceability, method validation and proficiency testing. There are some areas where lessons can be learned, for example in the assessment of measurement uncertainty; and it remains very instructive to see what the main causes of error are for IMSs in general. - Highlights: • EURADOS has surveyed QA practice amongst European dosimetry services. • The survey was comprehensive, covering most of the monitored workers in Europe. • The profile of QA among IMS is reassuringly high. • Many services follow formal QA standards, e.g. ISO 17025. • But there are still some lessons that can be learned

  5. Survey on Password Quality and Confidentiality

    OpenAIRE

    Šolić, Krešimir; Očevčić, Hrvoje; Blažević, Damir

    2015-01-01

    In this paper are presented results of empirical survey on password quality self-assessment and several privacy issues regarding password manipulation among information systems' users. Data was collected by questioning 627 e-mail users that were adults, Croatian national and were using e-mail system on regular basis. Comparisons among different kind of users were done regarding age, gender, technical background knowledge, university degree and experience in usage. Results of statistical analy...

  6. Exploratory survey of image quality on CR digital mammography imaging systems in Mexico

    International Nuclear Information System (INIS)

    Gaona, E.; Rivera, T.; Arreola, M.; Franco, J.; Molina, N.; Alvarez, B.; Azorín, C.G.; Casian, G.

    2014-01-01

    The purpose of this study was to assess the current status of image quality and dose in computed radiographic digital mammography (CRDM) systems. Studies included CRDM systems of various models and manufacturers which dose and image quality comparisons were performed. Due to the recent rise in the use of digital radiographic systems in Mexico, CRDM systems are rapidly replacing conventional film-screen systems without any regard to quality control or image quality standards. Study was conducted in 65 mammography facilities which use CRDM systems in the Mexico City and surrounding States. The systems were tested as used clinically. This means that the dose and beam qualities were selected using the automatic beam selection and photo-timed features. All systems surveyed generate laser film hardcopies for the radiologist to read on a scope or mammographic high luminance light box. It was found that 51 of CRDM systems presented a variety of image artefacts and non-uniformities arising from inadequate acquisition and processing, as well as from the laser printer itself. Undisciplined alteration of image processing settings by the technologist was found to be a serious prevalent problem in 42 facilities. Only four of them showed an image QC program which is periodically monitored by a medical physicist. The Average Glandular Dose (AGD) in the surveyed systems was estimated to have a mean value of 2.4 mGy. To improve image quality in mammography and make more efficient screening mammographic in early detection of breast cancer is required new legislation. - Highlights: • Radiation dose in CR digital mammography (CRDM) systems was determined. • Image quality related with dose in CR digital mammography (CRDM) systems was analysed. • Image processing artefacts were observed and correlated with dose. • Measured entrance dose by TL phosphors could be good parameter for radiation protection optimization in patient

  7. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  8. Schedule Control and Nursing Home Quality: Exploratory Evidence of a Psychosocial Predictor of Resident Care.

    Science.gov (United States)

    Hurtado, David A; Berkman, Lisa F; Buxton, Orfeu M; Okechukwu, Cassandra A

    2016-02-01

    To examine whether nursing homes' quality of care was predicted by schedule control (workers' ability to decide work hours), independently of other staffing characteristics. Prospective ecological study of 30 nursing homes in New England. Schedule control was self-reported via survey in 2011-2012 (N = 1,045). Quality measures included the prevalence of decline in activities of daily living, residents' weight loss, and pressure ulcers, indicators systematically linked with staffing characteristics. Outcomes data for 2012 were retrieved from Medicare.gov. Robust Linear Regressions showed that higher schedule control predicted lower prevalence of pressure ulcers (β = -0.51, p job satisfaction, and turnover intentions. Higher schedule control might enhance the planning and delivery of strategies to prevent or cure pressure ulcers. Further research is needed to identify potential causal mechanisms by which schedule control could improve quality of care. © The Author(s) 2014.

  9. Financial Record Checking in Surveys: Do Prompts Improve Data Quality?

    Science.gov (United States)

    Murphy, Joe; Rosen, Jeffrey; Richards, Ashley; Riley, Sarah; Peytchev, Andy; Lindblad, Mark

    2016-01-01

    Self-reports of financial information in surveys, such as wealth, income, and assets, are particularly prone to inaccuracy. We sought to improve the quality of financial information captured in a survey conducted by phone and in person by encouraging respondents to check records when reporting on income and assets. We investigated whether…

  10. Fact-finding survey of nosocomial infection control in hospitals in Vietnam and application to training programs.

    Science.gov (United States)

    Ohara, Hiroshi; Hung, Nguyen Viet; Thu, Truong Anh

    2009-12-01

    Nosocomial infection control is crucial for improving the quality of medical care. It is also indispensable for implementing effective control measures for severe acute respiratory syndrome (SARS) and the possible occurrence of a human influenza pandemic. The present authors, in collaboration with Vietnamese hospital staff, performed a fact-finding survey of nosocomial infection control in hospitals in northern Vietnam and compared the results with those of a survey conducted 4 years previously. Remarkable improvement was recognized in this period, although there were considerable differences between the central hospitals in Hanoi and local hospitals. In the local hospitals, basic techniques and the systems for infection control were regarded as insufficient, and it is necessary to improve these techniques and systems under the guidance of hospitals in the central area. Based on the results of the survey, programs were prepared and training courses were organized in local hospitals. Evaluation conducted after the training courses showed a high degree of satisfaction among the trainees. The results of the survey and the training courses conducted during the study period are expected to contribute to the improvement of nosocomial infection control in remote areas of Vietnam.

  11. Methods for computing water-quality loads at sites in the U.S. Geological Survey National Water Quality Network

    Science.gov (United States)

    Lee, Casey J.; Murphy, Jennifer C.; Crawford, Charles G.; Deacon, Jeffrey R.

    2017-10-24

    The U.S. Geological Survey publishes information on concentrations and loads of water-quality constituents at 111 sites across the United States as part of the U.S. Geological Survey National Water Quality Network (NWQN). This report details historical and updated methods for computing water-quality loads at NWQN sites. The primary updates to historical load estimation methods include (1) an adaptation to methods for computing loads to the Gulf of Mexico; (2) the inclusion of loads computed using the Weighted Regressions on Time, Discharge, and Season (WRTDS) method; and (3) the inclusion of loads computed using continuous water-quality data. Loads computed using WRTDS and continuous water-quality data are provided along with those computed using historical methods. Various aspects of method updates are evaluated in this report to help users of water-quality loading data determine which estimation methods best suit their particular application.

  12. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  13. Questionnaire survey on factors influencing comfort with indoor environmental quality in Danish housing

    DEFF Research Database (Denmark)

    Frontczak, Monika Joanna; Andersen, Rune Vinther; Wargocki, Pawel

    2012-01-01

    . A total of 2499 questionnaires were sent to inhabitants of the most common types of housing in Denmark; 645 persons replied (response rate of 26%). The results show that the main indoor environmental parameters (visual, acoustic and thermal conditions, and air quality) are considered by occupants......A questionnaire survey in Danish homes investigated the factors that influence occupants’ comfort. The questionnaire contained questions on inhabitants’ behaviour, their knowledge as regards building systems designed for controlling the indoor environment and the ways in which they achieve comfort...

  14. Influence of volunteer and project characteristics on data quality of biological surveys.

    Science.gov (United States)

    Lewandowski, Eva; Specht, Hannah

    2015-06-01

    Volunteer involvement in biological surveys is becoming common in conservation and ecology, prompting questions on the quality of data collected in such surveys. In a systematic review of the peer-reviewed literature on the quality of data collected by volunteers, we examined the characteristics of volunteers (e.g., age, prior knowledge) and projects (e.g., systematic vs. opportunistic monitoring schemes) that affect data quality with regards to standardization of sampling, accuracy and precision of data collection, spatial and temporal representation of data, and sample size. Most studies (70%, n = 71) focused on the act of data collection. The majority of assessments of volunteer characteristics (58%, n = 93) examined the effect of prior knowledge and experience on quality of the data collected, often by comparing volunteers with experts or professionals, who were usually assumed to collect higher quality data. However, when both groups' data were compared with the same accuracy standard, professional data were more accurate in only 4 of 7 cases. The few studies that measured precision of volunteer and professional data did not conclusively show that professional data were less variable than volunteer data. To improve data quality, studies recommended changes to survey protocols, volunteer training, statistical analyses, and project structure (e.g., volunteer recruitment and retention). © 2015, Society for Conservation Biology.

  15. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  16. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  17. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  18. A survey of Canadian medical physicists: software quality assurance of in-house software.

    Science.gov (United States)

    Salomons, Greg J; Kelly, Diane

    2015-01-05

    This paper reports on a survey of medical physicists who write and use in-house written software as part of their professional work. The goal of the survey was to assess the extent of in-house software usage and the desire or need for related software quality guidelines. The survey contained eight multiple-choice questions, a ranking question, and seven free text questions. The survey was sent to medical physicists associated with cancer centers across Canada. The respondents to the survey expressed interest in having guidelines to help them in their software-related work, but also demonstrated extensive skills in the area of testing, safety, and communication. These existing skills form a basis for medical physicists to establish a set of software quality guidelines.

  19. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  20. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  1. Social control of the quality of public services: Theory, methodology and results of empirical research

    Directory of Open Access Journals (Sweden)

    Evgeny A. Kapoguzov

    2017-06-01

    Full Text Available The article reveals the theoretical and methodological aspect of the problem of social control in relation to the possibility of its implementation in the production of public services. The interdisciplinary nature of the discourse on the nature of social control is presented, the evolution of ideas about it in the framework of social science concepts is presented, and the relationship with related categories is revealed, in particular, "public control", "civil control". The evolution of essence is also traced the category "institutionalization", it is shown the lack of unambiguousness in its interpretation. The normative value of the institutionalization of social practices in the implementation of institutional design is presented, in particular, with regard to the improvement of the provision of public services. The barriers of institutionalization of social control (resource, information, institutional for quality of public services are characterized. The results of a mass survey of consumers of public services conducted in December 2016 in the Multifunctional Center (MFC of city Omsk are presented. Unlike other surveys and publications that only assess the level of customer satisfaction and do not give a detailed explanation of the attitude of consumers to the ongoing institutional changes, this paper presents an analysis of consumer attitudes and beliefs to meaningful attributes of the quality of public services on the one hand, and for various institutional alternatives of influence on the quality of public services on the other. According to the results of the mass survey, the low readiness for social action was established due to high transaction costs, the rational ignorance and a free-rider problem. The possibility of institutionalizing the practice of social action and setting up consumers for the creation of a specialized organization for the protection of consumer rights in the production of public services was discussed.

  2. Groundwater-quality data from the National Water-Quality Assessment Project, January through December 2014 and select quality-control data from May 2012 through December 2014

    Science.gov (United States)

    Arnold, Terri L.; Bexfield, Laura M.; Musgrove, MaryLynn; Lindsey, Bruce D.; Stackelberg, Paul E.; Barlow, Jeannie R.; Desimone, Leslie A.; Kulongoski, Justin T.; Kingsbury, James A.; Ayotte, Joseph D.; Fleming, Brandon J.; Belitz, Kenneth

    2017-10-05

    Groundwater-quality data were collected from 559 wells as part of the National Water-Quality Assessment Project of the U.S. Geological Survey National Water-Quality Program from January through December 2014. The data were collected from four types of well networks: principal aquifer study networks, which are used to assess the quality of groundwater used for public water supply; land-use study networks, which are used to assess land-use effects on shallow groundwater quality; major aquifer study networks, which are used to assess the quality of groundwater used for domestic supply; and enhanced trends networks, which are used to evaluate the time scales during which groundwater quality changes. Groundwater samples were analyzed for a large number of water-quality indicators and constituents, including major ions, nutrients, trace elements, volatile organic compounds, pesticides, radionuclides, and some constituents of special interest (arsenic speciation, chromium [VI] and perchlorate). These groundwater-quality data, along with data from quality-control samples, are tabulated in this report and in an associated data release.

  3. A status report on dual energy x-ray absorptiometry quality control in Korea

    International Nuclear Information System (INIS)

    Kim, Jung Su; Ro, Young Hoon; Lee, In Ju; Kim, Jung Min; Kim, Sung Su; Kim, Kyoung Ah

    2016-01-01

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude

  4. A status report on dual energy x-ray absorptiometry quality control in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su [Dept. of Radiogic Technology, Chungbuk Health and Science University, Cheongju (Korea, Republic of); Ro, Young Hoon; Lee, In Ju; Kim, Jung Min [Dept. of Bio-convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); Kim, Sung Su [Dept. of Healthcare Management, Cheongju University, Cheongju (Korea, Republic of); Kim, Kyoung Ah [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-12-15

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

  5. Quality control analysis at the hospital

    International Nuclear Information System (INIS)

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  6. Gambaran Gejala Pernafasan Pada Pekerja Bagian Quality Control Pabrik Pengolahan Crude Palm Oil (Cpo) Pt.smart,tbk Di Belawan Tahun 2013

    OpenAIRE

    Wita, Rizka; Tarigan, Lina; Lubis, Halinda Sari

    2013-01-01

    Respiratory symptom description of Quality Control workers in crude palm oil processing plant PT. Smart Tbk Belawan on 2013. Occupational disease can decrease the health and welfare degree of workers, one of causes factor is chemical. The quality control workers always use chemical which corrosive and irritant to the respiratory system. The method of this research is descriptive survey research. Population is all of quality control workers totaling 36 person. Sample used is the total populati...

  7. Reporting quality of randomized controlled trial abstracts: survey of leading general dental journals.

    Science.gov (United States)

    Hua, Fang; Deng, Lijia; Kau, Chung How; Jiang, Han; He, Hong; Walsh, Tanya

    2015-09-01

    The authors conducted a study to assess the reporting quality of randomized controlled trial (RCT) abstracts published in leading general dental journals, investigate any improvement after the release of the Consolidated Standards of Reporting Trials (CONSORT) for Abstracts guidelines, and identify factors associated with better reporting quality. The authors searched PubMed for RCTs published in 10 leading general dental journals during the periods from 2005 to 2007 (pre-CONSORT period) and 2010 to 2012 (post-CONSORT period). The authors evaluated and scored the reporting quality of included abstracts by using the original 16-item CONSORT for Abstracts checklist. The authors used risk ratios and the t test to compare the adequate reporting rate of each item and the overall quality in the 2 periods. The authors used univariate and multivariate regressions to identify predictors of better reporting quality. The authors included and evaluated 276 RCT abstracts. Investigators reported significantly more checklist items during the post-CONSORT period (mean [standard deviation {SD}], 4.53 [1.69]) than during the pre-CONSORT period (mean [SD], 3.87 [1.10]; mean difference, -0.66 [95% confidence interval, -0.99 to -0.33]; P 80%). In contrast, the authors saw sufficient reporting of randomization, recruitment, outcome in the results section, and funding in none of the pre-CONSORT abstracts and less than 2% of the post-CONSORT abstracts. On the basis of the multivariate analysis, a higher impact factor (P general dental journals has improved significantly, but there is still room for improvement. Joint efforts by authors, reviewers, journal editors, and other stakeholders to improve the reporting of dental RCT abstracts are needed. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  8. Research on airborne comprehensive survey system of atmosphere quality

    International Nuclear Information System (INIS)

    Yu Zhentao; Yu Yanbin

    1998-01-01

    The global atmosphere pollution is becoming more and more serious, affecting the human existence and development. Besides, the high spectrum resolution remote sensing technique, which has been applied to observe topographic features, identify military objectives and distinguish lithology and vegetation, has the relation to atmosphere quality and is influenced by atmosphere pollution (including radon pollution) and dust content in the atmosphere, it is imperative to monitor atmosphere quality. Based upon the selection of some main parameters evaluating atmospheric quality and necessary equipment, the author introduces the design of multiple airborne comprehensive survey system of atmosphere quality and how to deal with problems that crop up during the hardware designing and software programming

  9. Quality-assurance plan for water-quality activities in the U.S. Geological Survey Washington Water Science Center

    Science.gov (United States)

    Conn, Kathleen E.; Huffman, Raegan L.; Barton, Cynthia

    2017-05-08

    In accordance with guidelines set forth by the Office of Water Quality in the Water Mission Area of the U.S. Geological Survey, a quality-assurance plan has been created for use by the Washington Water Science Center (WAWSC) in conducting water-quality activities. This qualityassurance plan documents the standards, policies, and procedures used by the WAWSC for activities related to the collection, processing, storage, analysis, and publication of water-quality data. The policies and procedures documented in this quality-assurance plan for water-quality activities complement the quality-assurance plans for surface-water and groundwater activities at the WAWSC.

  10. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  11. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  12. A survey of innovative contracting for quality jobs and ecosystem management.

    Science.gov (United States)

    Cassandra Moseley

    2002-01-01

    This survey identifies and defines innovative contracting mechanisms developed in the Forest Service Pacific Northwest Region and northern California. A survey of nine case studies reveals that several new mechanisms have facilitated ecosystem management, quality jobs, and administrative efficiencies, but at times innovation was hampered by Forest Service institutional...

  13. The current state of external quality control surveys in the German Federal Republic in the field of peptide hormone radioimmunoassays

    International Nuclear Information System (INIS)

    Marschner, I.; Scriba, P.C.; Wood, W.G.; Breuer, H.; Jungbluth, D.; Roehle, G.

    1977-01-01

    Two types of quality control surveys (QSC) are performed in the Federal Republic of Germany in the field of hormone assays: 1) The distribution of two lyophilized sera at regular intervals, in which the participants have to determine 7 or 8 different hormones. Because of the lack of reference methods for peptide hormones, the statistical evaluation of the results indicates only whether the results of the participants are 'correct' or contain systematic or nonsystematic errors with respect to the findings of the other participants. 2) The distribution of approximately 20 deep-frozen sera (including a standard curve in hormone-free serum) in which the participant has to assay a single hormone. These 20 sera-QCS are performed only at long intervals for a given hormone. The statistical analysis of the rate of the radioactive counts of the QCS-sera and those of the participants' standard curves allows - together with a methodological inquiry form - detection of probable causes for deviating results. (orig.) [de

  14. Quality Improvement in Otolaryngology Residency: Survey of Program Directors.

    Science.gov (United States)

    Bowe, Sarah N

    2016-02-01

    The Clinical Learning Environment Review focuses on the responsibility of the sponsoring institution for quality and patient safety. Very little information is known regarding the status of quality improvement (QI) education during otolaryngology training. The purpose of this survey is to evaluate the extent of resident and faculty participation in QI and identify opportunities for both resident curriculum and faculty development. Cross-sectional survey A 15-item survey was distributed to all 106 otolaryngology program directors. The survey was developed after an informal review of the literature regarding education in QI and patient safety. Questions were directed at the format and content of the QI curriculum, as well as barriers to implementation. There was a 39% response rate. Ninety percent of responding program directors considered education in QI important or very important to a resident's future success. Only 23% of responding programs contained an educational curriculum in QI, and only 33% monitored residents' individual outcome measures. Barriers to implementation of a QI program included inadequate number of faculty with expertise in QI (75%) and competing resident educational demands (90%). Every program director considered morbidity and mortality conferences as an integral component in QI education. Program directors recognize the importance of QI in otolaryngology practice. Unfortunately, this survey identifies a distinct lack of resources in support of these educational goals. The results highlight the need to generate a comprehensive and stepwise approach to QI for faculty development and resident instruction. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  15. A survey of Canadian medical physicists: software quality assurance of in‐house software

    Science.gov (United States)

    Kelly, Diane

    2015-01-01

    This paper reports on a survey of medical physicists who write and use in‐house written software as part of their professional work. The goal of the survey was to assess the extent of in‐house software usage and the desire or need for related software quality guidelines. The survey contained eight multiple‐choice questions, a ranking question, and seven free text questions. The survey was sent to medical physicists associated with cancer centers across Canada. The respondents to the survey expressed interest in having guidelines to help them in their software‐related work, but also demonstrated extensive skills in the area of testing, safety, and communication. These existing skills form a basis for medical physicists to establish a set of software quality guidelines. PACS number: 87.55.Qr PMID:25679168

  16. Related regulation of quality control of industrial products

    International Nuclear Information System (INIS)

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  17. Educational attainment, perceived control and the quality of women's diets.

    Science.gov (United States)

    Barker, Mary; Lawrence, Wendy; Crozier, Sarah; Robinson, Siân; Baird, Janis; Margetts, Barrie; Cooper, Cyrus

    2009-06-01

    Data from the Southampton Women's Survey have established that women of lower educational attainment have poorer quality diets than those of higher educational attainment. This relationship is strong and graded such that for every increase in level of educational qualification, there is an increase in the likelihood that a woman will have a better quality diet. It is not wholly explained by socio-economic status. Qualitative research carried out in Southampton suggests that women of lower educational attainment may have a poorer diet because they feel they lack control over the food choices they make for themselves and their families. We set out to investigate the relationship between educational attainment, perceived control and quality of diet in a sample of women from Southampton. Cross-sectional study using structured interviews in which women's diet, educational attainment and perceived control were assessed. 19 Children's Centres and baby clinics in Southampton, UK. 372 women, median age 28 years. Quality of diet assessed by prudent diet score produced from principal components analysis of 20-item food frequency questionnaire, and perceived control assessed by a validated questionnaire. Women of lower educational attainment tended to have lower prudent diet scores and lower perceived control scores than women of higher educational attainment. Having a lower prudent diet score was associated with consuming fewer vegetables and vegetable dishes, less wholemeal bread and vegetarian food, and more chips and roast potatoes, meat pies, Yorkshire puddings and pancakes, crisps and snacks, white bread and added sugar. In a regression model both lower educational attainment and lower perceived control were associated with lower prudent diet scores, independent of the effects of confounding factors. However there was an interaction effect such that lower perceived control was only related to prudent diet score in the group of women of lower educational attainment. Women

  18. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  19. Does Internal Quality Management Contribute to More Control or to Improvement of Higher Education?: A Survey on Faculty's Perceptions

    Science.gov (United States)

    Kleijnen, Jan; Dolmans, Diana; Willems, Jos; van Hout, Hans

    2011-01-01

    Purpose: The purpose of this paper is to explore faculty's perceptions of quality management activities (QMA) within their departments, attention being paid to relevant quality aspects and whether quality management contributes to control or improvement of higher education. Furthermore, it examines differences between departments and relationships…

  20. Human factors survey of advanced instrumentation and controls technologies in nuclear plants

    International Nuclear Information System (INIS)

    Carter, R.J.

    1992-01-01

    A survey of advanced instrumentation and controls (I ampersand C) technologies and associated human factors issues in the US and Canadian nuclear industries was carried out by a team from Oak Ridge national laboratory to provide background for the development of regulatory policy, criteria, and guides for review of advanced I ampersand C systems as well as human engineering guidelines for evaluating these systems. The survey found those components of the US nuclear industry surveyed to be quite interested in advanced I ampersand C, but very cautious in implementing such systems in nuclear facilities and power plants. The trend in the facilities surveyed is to experiment cautiously when there is an intuitive advantage or short-term payoff. In the control room, the usual practice is direct substitution of digital and microprocessor-based instruments or systems that are functionally identical to the analog instruments or systems being replaced. The most advanced I ampersand C systems were found in the Canadian CANDU plants, where the newest plant has digital system in almost 100% of its control systems and in over 70% of its plant protection system. The hypothesis that properly 'introducing digital systems increases safety' is supported by the Canadian experience. The performance of these digital systems was achieved using an appropriate quality assurance program for the software development. The ability of digital systems to detect impending failures and initiate a fail-safe action, is a significant safety issue that should be of special interest to every US utility as well as to the US Nuclear Regulatory Commission. (orig.)

  1. Measuring fertility through mobile‒phone based household surveys: Methods, data quality, and lessons learned from PMA2020 surveys

    OpenAIRE

    Yoonjoung Choi; Qingfeng Li; Blake Zachary

    2018-01-01

    Background: PMA2020 is a survey platform with resident enumerators using mobile phones. Instead of collecting full birth history, total fertility rates (TFR) have been measured with a limited number of questions on recent births. Employing new approaches provides opportunities to test and advance survey methods. Objective: This study aims to assess the quality of fertility data in PMA2020 surveys, focusing on bias introduced from the questionnaire and completeness and distribution of birth...

  2. A summary report on the 23rd quality control survey for immunoassays in Japan, 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-01

    The purpose of the survey is to improve the quality of in vitro tests and this report is its summary of immunoassays (the old name: RI in vitro tests) conducted in 2001. The survey was performed in 143 facilities out of 1,655 in Japan, which involved 20 national and public university hospitals, 16 private university hospitals, 21 national and public hospitals, 26 private hospitals, 41 hygiene test institutes and 19 reagent manufacturers. Tests examined were on 6 substances related to functions of pituitary, 5 of thyroid, 1 of parathyroid, 4 of gastro-intestine and pancreas, 5 of gonad and placenta, 4 of adrenal, 1 of renal-blood pressure regulation, on IgE, on digoxin and on 12 tumor-related substances. Tests were done on 2-3 samples supplied from the Committee and the mean, standard deviation and coefficient of variation were calculated for one way analysis of variance of within- and between-kit. Methods included those (65.4% vs 62.7% in 2000) with non-radioisotope like enzyme immunoassay (non-RI) and with radioisotopes like radioimmunoassay (RI). Dissociation between manufacturers of non-RI values without a common standard substance and between non-RI and RI values even with the same antibody was noted: the Committee considered these problems as their future task. (K.H.)

  3. A Survey of Current Valued Academic Leadership Qualities in Nursing.

    Science.gov (United States)

    Delgado, Cheryl; Mitchell, Maureen M

    2016-01-01

    An informal survey was used to identify nurse faculty leadership qualities currently valued and relevant. The accelerating retirement rate for seasoned leaders has created a need for nurse educators and academic leaders. Our school was concerned that we were not meeting students' needs for today's leadership challenges. We were also interested in the experiences of leadership preparation. This was a cross-sectional, online survey of faculty at top nursing schools as determined by US News & World Report. The top leadership qualities identified were integrity, communication clarity, and problem-solving ability. Current challenges for leaders were finding qualified faculty, obtaining resources, and team building. The results may guide curricular adjustments and the transition to a new generation of nurse academic leaders.

  4. Adaptive Critic Nonlinear Robust Control: A Survey.

    Science.gov (United States)

    Wang, Ding; He, Haibo; Liu, Derong

    2017-10-01

    Adaptive dynamic programming (ADP) and reinforcement learning are quite relevant to each other when performing intelligent optimization. They are both regarded as promising methods involving important components of evaluation and improvement, at the background of information technology, such as artificial intelligence, big data, and deep learning. Although great progresses have been achieved and surveyed when addressing nonlinear optimal control problems, the research on robustness of ADP-based control strategies under uncertain environment has not been fully summarized. Hence, this survey reviews the recent main results of adaptive-critic-based robust control design of continuous-time nonlinear systems. The ADP-based nonlinear optimal regulation is reviewed, followed by robust stabilization of nonlinear systems with matched uncertainties, guaranteed cost control design of unmatched plants, and decentralized stabilization of interconnected systems. Additionally, further comprehensive discussions are presented, including event-based robust control design, improvement of the critic learning rule, nonlinear H ∞ control design, and several notes on future perspectives. By applying the ADP-based optimal and robust control methods to a practical power system and an overhead crane plant, two typical examples are provided to verify the effectiveness of theoretical results. Overall, this survey is beneficial to promote the development of adaptive critic control methods with robustness guarantee and the construction of higher level intelligent systems.

  5. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  6. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  7. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  8. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  9. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  10. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  11. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  12. [Patient satisfaction survey and the place of users in the Oran university hospital quality project].

    Science.gov (United States)

    Chougrani, Saada; Ouhadj, Salah

    2014-01-01

    Quality of care is a strategic priority of any management approach in order to meet users' expectations of health care systems. This study tried to define the role of patient satisfaction surveys and the place of user in the quality of care project. The results of patient satisfaction surveys conducted between 2010 and 2012 and the draft quality of care project were analysed. Patient satisfaction surveys from 2010 to 2012 focused on logistic shortcomings. No comment was formulated about health care. Comments and suggestions did not provide any contribution in terms of patient involvement in the health care process. The multiple perspectives of quality of care include clinical care and other social objectives of respect for the individual and attention to the patient. User satisfaction as assessed by patient satisfaction surveys or patients' experiences only reflect the health professionals' representation. However, the objective is to measure what the user perceives and feels and his/her representation of the attention provided. These approaches, conducted outside of the quality of care strategic plan, only provide a basis for actions with limited or no effectiveness.

  13. Survey of water quality in Moradbeik river basis on WQI index by GIS

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Samadi

    2015-01-01

    Full Text Available Background: Survey of pollution and evaluation of water quality in rivers with Oregon Water Quality Index (OWQI and GIS are effective tools for management of the impact of environmental water resources. The information in calculating the WQI of Moradbeikriver allowed us to take our tests results and make a scientific conclusion about the quality of water. GIS can be a powerful tool for developing solutions for water resources problems for assessing water quality, determining water availability, preventing flooding, understanding the natural environment, and managing water resources on a local or regional scale. Methods: The WQI of Moradbeikriver consists of nine tests: Fecal Coliform (FC, Biochemical Oxygen Demand (BOD5, Nitrates (NO3, Total Phosphate (PO4, pH, temperature, Dissolved Oxygen (DO, turbidity, and Total Solid (TS. Water quality of Moradbeikriver was investigated for 12 months. Concentrations of these nine variables were normalized on a scale from 0 to 100 and translated into statements of water quality (excellent, good, regular, fair, and poor. Also this data were analyzed with WQI index, and then river basis on water quality was zoning by GIS. Results: The average of WQI was 61.62, which corresponded to ‘‘medium’’ quality water at the sampling point 1 (best station and decreased to around 26.41 (bad quality at sampling point 6. The association between sampling points and water quality indexes was statistically significant (P<0.05. Conclusion: Based on physical, chemical and biological agent monitoring and also with control of water quality indexes of these points, we observed wastewater and other river pollutants.

  14. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  15. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  16. Evaluating the quality of sampling frames used in European cross-national surveys

    NARCIS (Netherlands)

    Maineri, A.M.; Scherpenzeel, A.; Bristle, Johanna; Pflüger, Senta-Melissa; Butt, Sarah; Zins, Stefan; Emery, Tom; Luijkx, R.

    This report addresses the quality of the population registers which are currently being used as sampling frames in countries participating in the four cross-European surveys cooperating in SERISS: the European Social Survey (ESS), the European Values Study (EVS), the Gender and Generations Program

  17. An overview of quality control practices in Ontario with particular reference to cholesterol analysis.

    Science.gov (United States)

    Krishnan, S; Webb, S; Henderson, A R; Cheung, C M; Nazir, D J; Richardson, H

    1999-03-01

    The Laboratory Proficiency Testing Program (LPTP) assesses the analytical performance of all licensed laboratories in Ontario. The LPTP Enzymes, Cardiac Markers, and Lipids Committee conducted a "Patterns of Practice" survey to assess the in-house quality control (QC) practices of laboratories in Ontario using cholesterol as the QC paradigm. The survey was questionnaire-based seeking information on statistical calculations, software rules, review process and data retention, and so on. Copies of the in-house cholesterol QC graphs were requested. A total of 120 of 210 laboratories were randomly chosen to receive the questionnaires during 1995 and 1996; 115 laboratories responded, although some did not answer all questions. The majority calculate means and standard deviations (SD) every month, using anywhere from 4 to >100 data points. 65% use a fixed mean and SD, while 17% use means calculated from the previous month. A few use a floating or cumulative mean. Some laboratories that do not use fixed means use a fixed SD. About 90% use some form of statistical quality control rules. The most common rules used to detect random error are 1(3s)/R4s while 2(2s)/4(1s)/10x are used for systematic errors. About 20% did not assay any QC at levels >5.5 mmol/L. Quality control data are reviewed daily (technologists), weekly and monthly (supervisors/directors). Most laboratories retain their QC records for up to 3 years on paper and magnetic media. On some QC graphs the mean and SD, QC product lot number, or reference to action logs are not apparent. Quality control practices in Ontario are, therefore, disappointing. Improvement is required in the use of clinically appropriate concentrations of QC material and documentation on QC graphs.

  18. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  19. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  20. Asthma control in Latin America: the Asthma Insights and Reality in Latin America (AIRLA) survey.

    Science.gov (United States)

    Neffen, Hugo; Fritscher, Carlos; Schacht, Francisco Cuevas; Levy, Gur; Chiarella, Pascual; Soriano, Joan B; Mechali, Daniel

    2005-03-01

    The aims of this survey were (1) to assess the quality of asthma treatment and control in Latin America, (2) to determine how closely asthma management guidelines are being followed, and (3) to assess perception, knowledge and attitudes related to asthma in Latin America. We surveyed a household sample of 2,184 adults or parents of children with asthma in 2003 in 11 countries in Latin America. Respondents were asked about healthcare utilization, symptom severity, activity limitations and medication use. Daytime asthma symptoms were reported by 56% of the respondents, and 51% reported being awakened by their asthma at night. More than half of those surveyed had been hospitalized, attended a hospital emergency service or made unscheduled emergency visits to other healthcare facilities for asthma during the previous year. Patient perception of asthma control did not match symptom severity, even in patients with severe persistent asthma, 44.7% of whom regarded their disease as being well or completely controlled. Only 2.4% (2.3% adults and 2.6% children) met all criteria for asthma control. Although 37% reported treatment with prescription medications, only 6% were using inhaled corticosteroids. Most adults (79%) and children (68%) in this survey reported that asthma symptoms limited their activities. Absence from school and work was reported by 58% of the children and 31% of adults, respectively. Asthma control in Latin America falls short of goals in international guidelines, and in many aspects asthma care and control in Latin America suffer from the same shortcomings as in other areas of the world.

  1. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  2. [Quality control in herbal supplements].

    Science.gov (United States)

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  3. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  4. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  5. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  6. Spanish Adaptation and Validation of the Family Quality of Life Survey

    Science.gov (United States)

    Verdugo, M. A.; Cordoba, L.; Gomez, J.

    2005-01-01

    Background: Assessing the quality of life (QOL) for families that include a person with a disability have recently become a major emphasis in cross-cultural QOL studies. The present study examined the reliability and validity of the Family Quality of Life Survey (FQOL) on a Spanish sample. Method and Results: The sample comprised 385 families who…

  7. Evaluating survey quality in health services research: a decision framework for assessing nonresponse bias.

    Science.gov (United States)

    Halbesleben, Jonathon R B; Whitman, Marilyn V

    2013-06-01

    To address the issue of nonresponse as problematic and offer appropriate strategies for assessing nonresponse bias. A review of current strategies used to assess the quality of survey data and the challenges associated with these strategies is provided along with appropriate post-data collection techniques that researchers should consider. Response rates are an incomplete assessment of survey data quality, and quick reactions to response rate should be avoided. Based on a five-question decision making framework, we offer potential ways to assess nonresponse bias, along with a description of the advantages and disadvantages to each. It is important that the quality of survey data be considered to assess the relative contribution to the literature of a given study. Authors and funding agencies should consider the potential effects of nonresponse bias both before and after survey administration and report the results of assessments of nonresponse bias in addition to response rates. © Health Research and Educational Trust.

  8. Measuring fertility through mobile‒phone based household surveys: Methods, data quality, and lessons learned from PMA2020 surveys

    Directory of Open Access Journals (Sweden)

    Yoonjoung Choi

    2018-05-01

    Full Text Available Background: PMA2020 is a survey platform with resident enumerators using mobile phones. Instead of collecting full birth history, total fertility rates (TFR have been measured with a limited number of questions on recent births. Employing new approaches provides opportunities to test and advance survey methods. Objective: This study aims to assess the quality of fertility data in PMA2020 surveys, focusing on bias introduced from the questionnaire and completeness and distribution of birth month and year, and to estimate TFR adjusted for identified data quality issues. Methods: To assess underestimation from the questionnaire, we simulated births that would be counted using the PMA2020 questionnaires compared to births identified from full birth history. We analyzed the latest Demographic and Health Surveys in ten countries where PMA2020 surveys have been implemented. We assessed the level of reporting completeness for birth month and year and heaping of birth month, analyzing 39 PMA2020 surveys. Finally, TFR were calculated and adjusted for biases introduced from the questionnaire and heaping in birth month. Results: Simple questions introduced minor bias from undercounting multiple births, which was expected and correctable. Meanwhile, incomplete reporting of birth month was relatively high, and the default value of January in data collection software systematically moved births with missing months out of the reference period. On average across the 39 surveys, TFR increased by 1.6Š and 2.4Š, adjusted for undercounted multiple births and heaping on January, respectively. Contribution: This study emphasizes the importance of enumerator training and provides critical insight in software programming in surveys using mobile technologies.

  9. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  10. 18 CFR 12.40 - Quality control programs.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  11. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  12. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  13. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  14. Quality-assurance plan for water-resources activities of the U.S. Geological Survey in Idaho

    Science.gov (United States)

    Packard, F.A.

    1996-01-01

    To ensure continued confidence in its products, the Water Resources Division of the U.S. Geological Survey implemented a policy that all its scientific work be performed in accordance with a centrally managed quality-assurance program. This report establishes and documents a formal policy for current (1995) quality assurance within the Idaho District of the U.S. Geological Survey. Quality assurance is formalized by describing district organization and operational responsibilities, documenting the district quality-assurance policies, and describing district functions. The districts conducts its work through offices in Boise, Idaho Falls, Twin Falls, Sandpoint, and at the Idaho National Engineering Laboratory. Data-collection programs and interpretive studies are conducted by two operating units, and operational and technical assistance is provided by three support units: (1) Administrative Services advisors provide guidance on various personnel issues and budget functions, (2) computer and reports advisors provide guidance in their fields, and (3) discipline specialists provide technical advice and assistance to the district and to chiefs of various projects. The district's quality-assurance plan is based on an overall policy that provides a framework for defining the precision and accuracy of collected data. The plan is supported by a series of quality-assurance policy statements that describe responsibilities for specific operations in the district's program. The operations are program planning; project planning; project implementation; review and remediation; data collection; equipment calibration and maintenance; data processing and storage; data analysis, synthesis, and interpretation; report preparation and processing; and training. Activities of the district are systematically conducted under a hierarchy of supervision an management that is designed to ensure conformance with Water Resources Division goals quality assurance. The district quality

  15. Quality Control in construction.

    Science.gov (United States)

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  16. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  17. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  18. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  19. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  20. Geodetic Control Points - National Geodetic Survey Benchmarks

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — This data contains a set of geodetic control stations maintained by the National Geodetic Survey. Each geodetic control station in this dataset has either a precise...

  1. Trypanosoma brucei gambiense trypanosomiasis in Terego county, northern Uganda, 1996: a lot quality assurance sampling survey.

    Science.gov (United States)

    Hutin, Yvan J F; Legros, Dominique; Owini, Vincent; Brown, Vincent; Lee, Evan; Mbulamberi, Dawson; Paquet, Christophe

    2004-04-01

    We estimated the pre-intervention prevalence of Trypanosoma brucei gambiense (Tbg) trypanosomiasis using the lot quality assurance sampling (LQAS) methods in 14 parishes of Terego County in northern Uganda. A total of 826 participants were included in the survey sample in 1996. The prevalence of laboratory confirmed Tbg trypanosomiasis adjusted for parish population sizes was 2.2% (95% confidence interval =1.1-3.2). This estimate was consistent with the 1.1% period prevalence calculated on the basis of cases identified through passive and active screening in 1996-1999. Ranking of parishes in four categories according to LQAS analysis of the 1996 survey predicted the prevalences observed during the first round of active screening in the population in 1997-1998 (P LQAS were validated by the results of the population screening, suggesting that these survey methods may be useful in the pre-intervention phase of sleeping sickness control programs.

  2. Analysis of Quality of Proxy Questions in Health Surveys by Behavior Coding

    NARCIS (Netherlands)

    Benitez, I.; Padilla, J.L.; Ongena, Yfke

    2012-01-01

    The aim of this study is to show how to analyze the quality of questions for proxy informants by means of behavior coding. Proxy questions can undermine survey data quality because of the fact that proxies respond to questions on behalf of other people. Behavior coding can improve questions by

  3. Rurality and nursing home quality: evidence from the 2004 National Nursing Home Survey.

    Science.gov (United States)

    Kang, Yu; Meng, Hongdao; Miller, Nancy A

    2011-12-01

    To evaluate the impact of rural geographic location on nursing home quality of care in the United States. The study used cross-sectional observational design. We obtained resident- and facility-level data from 12,507 residents in 1,174 nursing homes from the 2004 National Nursing Home Survey. We used multilevel regression models to predict risk-adjusted rates of hospitalization, influenza and pneumococcal vaccination, and moderate to severe pain while controlling for resident and facility characteristics. Adjusting for covariates, residents in rural facilities were more likely to experience hospitalization (odds ratio [OR] = 1.50, 95% confidence interval [CI] = 1.16-1.94) and moderate to severe pain (OR = 1.68, 95% CI = 1.35-2.09). Significant facility-level predictors of higher quality included higher percentage of Medicaid beneficiaries, accreditation status, and special care programs. Medicare payment findings were mixed. Significant resident-level predictors included dementia diagnosis and being a "long-stay" resident. Rural residents were more likely to reside in facilities without accreditations or special care programs, factors that increased their odds of receiving poorer quality of care. Policy efforts to enhance Medicare payment approaches as well as increase rural facilities' accreditation status and provision of special care programs will likely reduce quality of care disparities in facilities.

  4. Quality in-training initiative--a solution to the need for education in quality improvement: results from a survey of program directors.

    Science.gov (United States)

    Kelz, Rachel R; Sellers, Morgan M; Reinke, Caroline E; Medbery, Rachel L; Morris, Jon; Ko, Clifford

    2013-12-01

    The Next Accreditation System and the Clinical Learning Environment Review Program will emphasize practice-based learning and improvement and systems-based practice. We present the results of a survey of general surgery program directors to characterize the current state of quality improvement in graduate surgical education and introduce the Quality In-Training Initiative (QITI). In 2012, a 20-item survey was distributed to 118 surgical residency program directors from ACS NSQIP-affiliated hospitals. The survey content was developed in collaboration with the QITI to identify program director opinions regarding education in practice-based learning and improvement and systems-based practice, to investigate the status of quality improvement education in their respective programs, and to quantify the extent of resident participation in quality improvement. There was a 57% response rate. Eighty-five percent of program directors (n = 57) reported that education in quality improvement is essential to future professional work in the field of surgery. Only 28% (n = 18) of programs reported that at least 50% of their residents track and analyze their patient outcomes, compare them with norms/benchmarks/published standards, and identify opportunities to make practice improvements. Program directors recognize the importance of quality improvement efforts in surgical practice. Subpar participation in basic practice-based learning and improvement activities at the resident level reflects the need for support of these educational goals. The QITI will facilitate programmatic compliance with goals for quality improvement education. Copyright © 2013 American College of Surgeons. All rights reserved.

  5. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  6. Random survey of the microbial quality of bottled water in South Africa

    African Journals Online (AJOL)

    Random survey of the microbial quality of bottled water in South Africa. Marthie M Ehlers, Walda B Van Zyl, Dobromir N Pavlov, Etienne E Muller. Abstract. Due to the increased demand and consumption of bottled water in South Africa, there has been a growing concern about the microbiological quality of this product.

  7. A Comparison of Power Quality Controllers

    Directory of Open Access Journals (Sweden)

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  8. quality control

    International Nuclear Information System (INIS)

    Skujina, A.; Purina, S.; Riekstina, D.

    1999-01-01

    The optimal objects: soils, spruce needles and bracken ferns were found for the environmental monitoring in the regions of possible radioactive contamination - near SalaspiIs nuclear reactor and Ignalina nuclear power plant. The determination of Sr-90 was based on the radiochemical separation of Sr-90 (=Y-90) by HDEHP extraction and counting the Cerenkov radiation. The quality control of the results was carried out. (authors)

  9. Influence of staff infection control training on infection-related quality measures in US nursing homes.

    Science.gov (United States)

    Kaur, Jasjit; Stone, Patricia W; Travers, Jasmine L; Cohen, Catherine C; Herzig, Carolyn T A

    2017-09-01

    Health care-associated infections are a leading cause of morbidity and mortality in US nursing home residents. Ongoing training of nursing home staff is vital to the implementation of infection prevention and control processes. Our aim was to describe associations between methods, frequency, and timing of staff infection prevention and control training and infection-related quality measures. In this national survey of nursing homes, timing of staff infection prevention and control training was associated with reduced indwelling urinary catheter use. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Methods and applications of statistics in engineering, quality control, and the physical sciences

    CERN Document Server

    Balakrishnan, N

    2011-01-01

    Inspired by the Encyclopedia of Statistical Sciences, Second Edition (ESS2e), this volume presents a concise, well-rounded focus on the statistical concepts and applications that are essential for understanding gathered data in the fields of engineering, quality control, and the physical sciences. The book successfully upholds the goals of ESS2e by combining both previously-published and newly developed contributions written by over 100 leading academics, researchers, and practitioner in a comprehensive, approachable format. The result is a succinct reference that unveils modern, cutting-edge approaches to acquiring and analyzing data across diverse subject areas within these three disciplines, including operations research, chemistry, physics, the earth sciences, electrical engineering, and quality assurance. In addition, techniques related to survey methodology, computational statistics, and operations research are discussed, where applicable. Topics of coverage include: optimal and stochastic control, arti...

  11. Quality of reporting web-based and non-web-based survey studies: What authors, reviewers and consumers should consider.

    Science.gov (United States)

    Turk, Tarek; Elhady, Mohamed Tamer; Rashed, Sherwet; Abdelkhalek, Mariam; Nasef, Somia Ahmed; Khallaf, Ashraf Mohamed; Mohammed, Abdelrahman Tarek; Attia, Andrew Wassef; Adhikari, Purushottam; Amin, Mohamed Alsabbahi; Hirayama, Kenji; Huy, Nguyen Tien

    2018-01-01

    Several influential aspects of survey research have been under-investigated and there is a lack of guidance on reporting survey studies, especially web-based projects. In this review, we aim to investigate the reporting practices and quality of both web- and non-web-based survey studies to enhance the quality of reporting medical evidence that is derived from survey studies and to maximize the efficiency of its consumption. Reporting practices and quality of 100 random web- and 100 random non-web-based articles published from 2004 to 2016 were assessed using the SUrvey Reporting GuidelinE (SURGE). The CHERRIES guideline was also used to assess the reporting quality of Web-based studies. Our results revealed a potential gap in the reporting of many necessary checklist items in both web-based and non-web-based survey studies including development, description and testing of the questionnaire, the advertisement and administration of the questionnaire, sample representativeness and response rates, incentives, informed consent, and methods of statistical analysis. Our findings confirm the presence of major discrepancies in reporting results of survey-based studies. This can be attributed to the lack of availability of updated universal checklists for quality of reporting standards. We have summarized our findings in a table that may serve as a roadmap for future guidelines and checklists, which will hopefully include all types and all aspects of survey research.

  12. Developing methods of controlling quality costs

    OpenAIRE

    Gorbunova A. V.; Maximova O. N.; Ekova V. A.

    2017-01-01

    The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding eva...

  13. Quality assurance and quality control for Hydro-Quebec's ambient air monitoring networks

    International Nuclear Information System (INIS)

    Lambert, M.; Varfalvy, L.

    1993-01-01

    Hydro Quebec has three ambient air monitoring networks to determine the contribution of some of its thermal plants to ambient air quality. They are located in Becancour (gas turbines), Iles-de-la-Madeleine (diesel), and Tracy (conventional oil-fired). To ensure good quality results and consistency between networks, a quality assurance/quality control program was set up. A description is presented of the ambient air quality monitoring network and the quality assurance/quality control program. A guide has been created for use by the network operators, discussing objectives of the individual network, a complete description of each network, field operation for each model of instrument in use, treatment of data for each data logger in use, global considerations regarding quality assurance and control, and reports. A brief overview is presented of the guide's purpose and contents, focusing on the field operation section and the sulfur dioxide and nitrogen oxide monitors. 6 figs., 1 tab

  14. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  15. Qualities of a psychiatric mentor: a quantitative Singaporean survey.

    Science.gov (United States)

    Tor, Phern-Chern; Goh, Lee-Gan; Ang, Yong-Guan; Lim, Leslie; Winslow, Rasaiah-Munidasa; Ng, Beng-Yeong; Wong, Sze-Tai; Ng, Tse-Pin; Kia, Ee-Heok

    2011-11-01

    Psychiatric mentors are an important part of the new, seamless training program in Singapore. There is a need to assess the qualities of a good psychiatric mentor vis-à-vis those of a good psychiatrist. An anonymous survey was sent out to all psychiatry trainees and psychiatrists in Singapore to assess quantitatively the relative importance of 40 qualities for a good psychiatrist and a good mentor. The response rate was 48.7% (74/152). Factor analysis showed four themes among the qualities assessed (professional, personal values, relationship, academic-executive). A good mentor is defined by professional, relationship, and personal-values qualities. Mentors have significantly higher scores than psychiatrists for two themes (relationship and academic-executive). Being a good mentor, in Asia, means being a good psychiatrist first and foremost but also requires additional relationship and academic-executive skills. Mentors should be formally trained in these additional skills that were not part of the psychiatric curriculum.

  16. Survey of occupant behaviour, energy use and indoor air quality in Greenlandic dwellings

    DEFF Research Database (Denmark)

    Kotol, Martin

    , they provide their occupants with poor indoor air quality. A questionnaire survey was performed in the town of Sisimiut-Greenland, which with its location and population represents Greenlandic conditions quite well. The aim of the survey was to investigate the energy consumption and indoor air quality...... in arctic dwellings and to study the influence of occupant behaviour of people living in arctic climates on energy consumption and indoor air quality. The results have shown that the average electricity consumption is 20% higher than in DK, ventilation systems are insufficient and that the inhabitants often......In cold arctic regions people usually spend over 70% of their time indoors. The effect of poor indoor air quality on occupants’ health and comfort is therefore considerable. Dwellings in Greenland consume very large amounts of energy (in average over 370 kWh/year per m2) and in addition...

  17. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  18. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    Science.gov (United States)

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  19. Report on Survey of Industry Needs for Quality. Summary Report.

    Science.gov (United States)

    Neylon, Kevin; And Others

    The TAFE (Technical and Further Education) National Centre for Research and Development conducted a survey to determine industry needs for quality training in Australia. Interviews were conducted with managers in manufacturing and tourism/hospitality companies throughout Australia, especially with firms with a high reputation. Interview forms were…

  20. Measuring the quality of infection control in Dutch nursing homes using a standardized method; the Infection prevention RIsk Scan (IRIS)

    NARCIS (Netherlands)

    Willemsen, I.; Nelson-Melching, J.; Hendriks, Y.; Mulders, A.; Verhoeff, S.; Kluytmans-Vandenbergh, M.; Kluytmans, J.

    2014-01-01

    BACKGROUND: We developed a standardised method to assess the quality of infection control in Dutch Nursing Home (NH), based on a cross-sectional survey that visualises the results. The method was called the Infection control RIsk Infection Scan (IRIS). We tested the applicability of this new tool in

  1. Human factors survey of advanced instrumentation and controls

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    A survey oriented towards identifying the human factors issues in regard to the use of advanced instrumentation and controls (I ampersand C) in the nuclear industry was conducted. A number of United States (US) and Canadian nuclear vendors and utilities were participants in the survey. Human factors items, subsumed under the categories of computer-generated displays (CGD), controls, organizational support, training, and related topics, were discussed. The survey found the industry to be concerned about the human factors issues related to the implementation of advanced I ampersand C. Fifteen potential human factors problems were identified. They include: the need for an advanced I ampersand C guideline equivalent to NUREG-0700; a role change in the control room from operator to supervisor; information overload; adequacy of existing training technology for advanced I ampersand C; and operator acceptance and trust. 11 refs., 1 tab

  2. [Quality control at the Istituto di Anatomia e Istologia patologica at the Università di Bologna].

    Science.gov (United States)

    Alampi, G; Baroni, R; Berti, E; Ceccarelli, C; Dina, R; Eusebi, V; Giangaspero, F; Grigioni, F W; Lecce, S; Losi, L

    1994-04-01

    The growing importance in medical practice of a standardized diagnosis in cyto- and histopathology and the recent recommendations for the adoption of standardized schemes for quality control in anatomic pathology by International Committees stimulated the medical staff of the Institute of Anatomic Pathology of the University of Bologna to adopt a pertinent method. The method used by the Department of Pathology of the Yale University (New Haven, Connecticut, USA) was chosen. A Committee for the quality control was appointed and two kinds of controls were set up: an External Quality Assessment (review of the difficult cases by external experts, slide seminars) and an Internal Quality Assessment performed by the members of the Committee on the diagnostic and laboratory routine of the Institute. Such a survey is periodically monitored during the monthly meetings of the Committee and described in the monthly reports. The present paper illustrates the method adopted and the preliminary results obtained in order to stimulate the discussion of such a critical theme in contemporary Anatomic Pathology at a national level.

  3. National Survey on Internal Quality Control Practice for Lipid Parameters in Laboratories of China from 2014 to 2016.

    Science.gov (United States)

    Ye, Yuanyuan; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-01

    To investigate the situation of Internal Quality Control (IQC) practice for total cholesterol, triglycerides, HDL-cholesterol and LDL-cholesterol from 2014 to 2016 in laboratories in China and provide improvement measurements. A web-based External Quality Assessment (EQA) system was used to collect IQC data of lipid parameters in laboratories which continuously participated in the national EQA programs in China from 2014 to 2016. Pass rate of the coefficients of variation (CVs) of two level quality controls in four lipid parameters were calculated according to six quality specifications for precision to evaluate the current status of precision level of the four lipid parameters and their change over time in China. 533, 512, 504, and 466 laboratories continuously reported the data of level one for total cholesterol, triglyceride, HDL-cholesterol and LDL-cholesterol, and 212, 210, 208 and 198 laboratories reported the level two, respectively. The percentage of laboratories meeting the quality specification varied based on different criteria. Non-significant change can be found in the pass rate of CVs over time. The number of laboratories using a closed system increased over time, but still only accounted for a small proportion. There is no significant difference in the pass rate of CVs between closed and open systems. Triglycerides currently have a fairly good performance in China. While the performance of laboratories on total cholesterol, HDL-cholesterol and LDL-cholesterol has yet to be improved.

  4. The data on health locus of control and its relationship with quality of life in HIV-positive patients

    Directory of Open Access Journals (Sweden)

    Zahra Mostafavian

    2018-06-01

    Full Text Available Locus of control is a concept defined based on social learning theory, and focuses on individuals' beliefs regarding factors that influence their health status. Health Locus of Control (HLC and its relationship with Quality of Life (QOL in HIV positive patients in local population were studied. This was a cross-sectional study on 80 HIV-positive patients. Multidimensional Health Locus of Control (MHLC Scale and Medical Outcome Study Short-Form Health Survey (MOS-SF-36 used to measure patients' HLC and QOL, respectively. Internal, external, and chance HLC mean ± SD scores were 30.31±3.87, 24.17±5.03, and 32.01±4.49, respectively. Positive correlation was found between internal HLC scores and both physical (p <0.001, r = 0.53 and mental quality of life (p <0.001, r = 0.48. Multiple regression analysis showed that internal HLC was the only significant predictor of quality of life. HIV-positive patients who believe their health is mostly influenced by individual's actions and behaviors (internal HLC showed a higher quality of life. These findings suggest that modifying health locus of control beliefs, hypothetically could influence patients' quality of life. Keywords: HIV, Health locus of control, Quality of life, Medicine

  5. A survey-based benchmarking approach for health care using the Baldrige quality criteria.

    Science.gov (United States)

    Jennings, K; Westfall, F

    1994-09-01

    Since 1988, manufacturing and service industries have been using the Malcolm Baldrige National Quality Award to assess their management processes (for example, leadership, information, and analysis) against critical performance criteria. Recognizing that the typical Baldrige assessment is time intensive and dependent on intensive training, The Pacer Group, a consulting firm in Dayton, Ohio, developed a self-assessment tool based on the Baldrige criteria which provides a snapshot assessment of an organization's management practices. The survey was administered at 25 hospitals within a health care system. Hospitals were able to compare their scores with other hospitals in the system, as well as the scores of a Baldrige award winner. Results were also analyzed on a systemwide basis to identify strengths and weaknesses across the system. For all 25 hospitals, the following areas were identified as strengths: management of process quality, leadership, and customer focus and satisfaction. Weaknesses included lack of employee involvement in the quality planning process, poor design of quality systems, and lack of cross-departmental cooperation. One of the surveyed hospitals launched improvement initiatives in knowledge of improvement tools and methods and in a patient satisfaction focus. A team was formed to improve the human resource management system. Also, a new unit was designed using patient-centered care principles. A team re-evaluated every operation that affected patients on the unit. A survey modeled after the Baldrige Award criteria can be useful in benchmarking an organization's quality improvement practices.

  6. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  7. The Advisor Quality Survey: Good College Advisors Are Available, Knowledgeable, and Autonomy Supportive

    Science.gov (United States)

    Sheldon, Kennon M.; Garton, Bryan; Orr, Rachael; Smith, Amy

    2015-01-01

    Most US institutions of higher education do not assess advisor quality. We report a scale development effort informed by the developmental prescriptions of self-determination theory (Deci & Ryan, 1985, 2000). The 15-item Missouri Advisor Quality Survey assesses advisor knowledge, advisor availability, and advisor autonomy supportiveness.…

  8. Key interventions and quality indicators for quality improvement of STEMI care: a RAND Delphi survey.

    Science.gov (United States)

    Aeyels, Daan; Sinnaeve, Peter R; Claeys, Marc J; Gevaert, Sofie; Schoors, Danny; Sermeus, Walter; Panella, Massimiliano; Coeckelberghs, Ellen; Bruyneel, Luk; Vanhaecht, Kris

    2017-12-13

    Identification, selection and validation of key interventions and quality indicators for improvement of in hospital quality of care for ST-elevated myocardial infarction (STEMI) patients. A structured literature review was followed by a RAND Delphi Survey. A purposively selected multidisciplinary expert panel of cardiologists, nurse managers and quality managers selected and validated key interventions and quality indicators prior for quality improvement for STEMI. First, 34 experts (76% response rate) individually assessed the appropriateness of items to quality improvement on a nine point Likert scale. Twenty-seven key interventions, 16 quality indicators at patient level and 27 quality indicators at STEMI care programme level were selected. Eighteen additional items were suggested. Experts received personal feedback, benchmarking their score with group results (response rate, mean, median and content validity index). Consequently, 32 experts (71% response rate) openly discussed items with an item-content validity index above 75%. By consensus, the expert panel validated a final set of 25 key interventions, 13 quality indicators at patient level and 20 quality indicators at care programme level prior for improvement of in hospital care for STEMI. A structured literature review and multidisciplinary expertise was combined to validate a set of key interventions and quality indicators prior for improvement of care for STEMI. The results allow researchers and hospital staff to evaluate and support quality improvement interventions in a large cohort within the context of a health care system.

  9. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  10. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  11. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  12. COLLABORATIVE TRIAL AND QUALITY CONTROL IN CHEMICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Narsito Narsito

    2010-06-01

    Full Text Available Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of analytical method, quality assurance in chemical analysis. The assessment of quality parameter for analytical method like the use of standard materials as well as standard methods is given. Concerning with the quality control of analytical data, the use of several techniques, such as control samples and control charts, in monitoring analytical data in quality control program are described qualitatively.  In the final part of this paper, some important remarks for the preparation of collaborative trials, including the evaluation of accuracy and reproducibility of analytical method are also given Keywords: collaborative trials, quality control, analytical data Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of

  13. 42 CFR 84.40 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory protection...

  14. 30 CFR 28.30 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  15. Evaluation of quality-control data collected by the U.S. Geological Survey for routine water-quality activities at the Idaho National Laboratory and vicinity, southeastern Idaho, 2002-08

    Science.gov (United States)

    Rattray, Gordon W.

    2014-01-01

    Quality-control (QC) samples were collected from 2002 through 2008 by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to ensure data robustness by documenting the variability and bias of water-quality data collected at surface-water and groundwater sites at and near the Idaho National Laboratory. QC samples consisted of 139 replicates and 22 blanks (approximately 11 percent of the number of environmental samples collected). Measurements from replicates were used to estimate variability (from field and laboratory procedures and sample heterogeneity), as reproducibility and reliability, of water-quality measurements of radiochemical, inorganic, and organic constituents. Measurements from blanks were used to estimate the potential contamination bias of selected radiochemical and inorganic constituents in water-quality samples, with an emphasis on identifying any cross contamination of samples collected with portable sampling equipment. The reproducibility of water-quality measurements was estimated with calculations of normalized absolute difference for radiochemical constituents and relative standard deviation (RSD) for inorganic and organic constituents. The reliability of water-quality measurements was estimated with pooled RSDs for all constituents. Reproducibility was acceptable for all constituents except dissolved aluminum and total organic carbon. Pooled RSDs were equal to or less than 14 percent for all constituents except for total organic carbon, which had pooled RSDs of 70 percent for the low concentration range and 4.4 percent for the high concentration range. Source-solution and equipment blanks were measured for concentrations of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, and dissolved chromium. Field blanks were measured for the concentration of iodide. No detectable concentrations were measured from the blanks except for strontium-90 in one source solution and one equipment blank collected in September

  16. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  17. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  18. Are managerial pressure, technological control and intrinsic motivation effective in improving data quality?

    International Nuclear Information System (INIS)

    Molina, Roger; Unsworth, Kerrie; Hodkiewicz, Melinda; Adriasola, Elisa

    2013-01-01

    Can data collectors be “pushed” into collecting high quality data or would being “pulled” be more effective? This paper finds that managers should be careful of the degree to which “push” factors, such as managerial pressure and technological input control, are relied upon. While they may be helpful for motivating those data collectors who are not intrinsically motivated, they are either not helpful or may discourage those data collectors who are intrinsically motivated. Instead, self-concordance may act as a longer-term, more stable approach to increasing the motivation of data collectors and thus increasing the quality of data that enter reliability systems. This study uses a sequential mixed-method approach involving interviews with 20 data collectors and a quantitative survey of 109 data collectors in a water utility. It examines the interactive effect of managerial pressure, technological input control and self-concordance on data collection performance

  19. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  20. Surface water-quality activities of the U.S. Geological Survey in New England

    Science.gov (United States)

    Huntington, Thomas G.

    2016-03-23

    The U.S. Geological Survey (USGS) collaborates with a variety of Federal, State, local, and tribal partners on scientific projects to provide reliable and impartial water-quality data and interpretation to resource managers, planners, stakeholders, and the general public. The themes related to surface water quality include the following:

  1. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  2. Intra- and Intercellular Quality Control Mechanisms of Mitochondria

    Directory of Open Access Journals (Sweden)

    Yoshimitsu Kiriyama

    2017-12-01

    Full Text Available Mitochondria function to generate ATP and also play important roles in cellular homeostasis, signaling, apoptosis, autophagy, and metabolism. The loss of mitochondrial function results in cell death and various types of diseases. Therefore, quality control of mitochondria via intra- and intercellular pathways is crucial. Intracellular quality control consists of biogenesis, fusion and fission, and degradation of mitochondria in the cell, whereas intercellular quality control involves tunneling nanotubes and extracellular vesicles. In this review, we outline the current knowledge on the intra- and intercellular quality control mechanisms of mitochondria.

  3. Fuel cycle and quality control

    International Nuclear Information System (INIS)

    Stoll, W.

    1979-01-01

    The volume of the fuel cycle is described in its economic importance and its through put, as it is envisaged for the Federal Republic of Germany. Definitions are given for quality continuing usefulness of an object and translated into quality criteria. Requirements on performance of fuel elements are defined. The way in which experimental results are translated into mass production of fuel rods, is described. The economic potential for further quality effort is derived. Future ways of development for quality control organisation and structure are outlined. (Auth.)

  4. Real-time patient survey data during routine clinical activities for rapid-cycle quality improvement.

    Science.gov (United States)

    Wofford, James Lucius; Campos, Claudia L; Jones, Robert E; Stevens, Sheila F

    2015-03-12

    Surveying patients is increasingly important for evaluating and improving health care delivery, but practical survey strategies during routine care activities have not been available. We examined the feasibility of conducting routine patient surveys in a primary care clinic using commercially available technology (Web-based survey creation, deployment on tablet computers, cloud-based management of survey data) to expedite and enhance several steps in data collection and management for rapid quality improvement cycles. We used a Web-based data management tool (survey creation, deployment on tablet computers, real-time data accumulation and display of survey results) to conduct four patient surveys during routine clinic sessions over a one-month period. Each survey consisted of three questions and focused on a specific patient care domain (dental care, waiting room experience, care access/continuity, Internet connectivity). Of the 727 available patients during clinic survey days, 316 patients (43.4%) attempted the survey, and 293 (40.3%) completed the survey. For the four 3-question surveys, the average time per survey was overall 40.4 seconds, with a range of 5.4 to 20.3 seconds for individual questions. Yes/No questions took less time than multiple choice questions (average 9.6 seconds versus 14.0). Average response time showed no clear pattern by order of questions or by proctor strategy, but monotonically increased with number of words in the question (30 words)-8.0, 11.8, 16.8, seconds, respectively. This technology-enabled data management system helped capture patient opinions, accelerate turnaround of survey data, with minimal impact on a busy primary care clinic. This new model of patient survey data management is feasible and sustainable in a busy office setting, supports and engages clinicians in the quality improvement process, and harmonizes with the vision of a learning health care system.

  5. A survey of radiotherapy quality control practice in the United Kingdom for the START trial

    International Nuclear Information System (INIS)

    Venables, Karen; Winfield, Elizabeth; Deighton, Amanda; Aird, Edwin; Hoskin, Peter

    2001-01-01

    Background and purpose: This paper compares the quality control checks performed in departments in the United Kingdom with those recommended by the Institute of Physics and Engineering in Medicine (IPEM) in Report 81. Method: The data were gathered by the quality assurance team for the START trial, during visits to individual departments. Data are compared with the frequencies suggested in IPEM report 81. Where applicable, data are also analyzed with respect to machine manufacturer. Results: All departments with linear accelerators check the output at least weekly for both photons and electrons, however 11% of departments do not perform a constancy check of the output on a daily basis. The majority of departments check flatness at gantry zero on a monthly basis. However 27% of departments never check at non-zero gantry angles. In 51% of departments no fluoroscopy checks are performed on simulators on a daily basis. Conclusion: The majority of departments are following the frequencies suggested in IPEM report 81 although there are a number of discrepancies particularly for simulators. Accelerator type needs to be considered when designing quality assurance checks. In many departments more time than is currently allocated is needed on equipment, particularly simulators, to complete all of the checks suggested in Report 81

  6. A survey on control schemes for distributed solar collector fields. Part II: Advanced control approaches

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, E.F.; Rubio, F.R. [Universidad de Sevilla, Escuela Superior de Ingenieros, Departamento de Ingenieria de Sistemas y Automatica, Camino de Los Descubrimientos s/n, E-41092 Sevilla (Spain); Berenguel, M. [Universidad de Almeria, Departamento de Lenguajes y Computacion, Area de Ingenieria de Sistemas y Automatica, Carretera Sacramento s/n, E-04120 La Canada, Almeria (Spain); Valenzuela, L. [Plataforma Solar de Almeria - CIEMAT, Carretera Senes s/n, P.O. Box 22, E-04200 Tabernas (Almeria) (Spain)

    2007-10-15

    This article presents a survey of the different advanced automatic control techniques that have been applied to control the outlet temperature of solar plants with distributed collectors during the last 25 years. A classification of the modeling and control approaches described in the first part of this survey is used to explain the main features of each strategy. The treated strategies range from classical advanced control strategies to those with few industrial applications. (author)

  7. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  8. Quality control of 11C-carfentanil

    International Nuclear Information System (INIS)

    Zhang Xiaojun; Zhang Jinming; Tian Jiahe; Xiang Xiaohui

    2013-01-01

    To study the quality control of 11 C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11 C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11 C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  9. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  10. Quality of Life Among Dental Students: A Survey Study.

    Science.gov (United States)

    Andre, Amanda; Pierre, Gaelle C; McAndrew, Maureen

    2017-10-01

    Quality of life is a complex construct that affects the overall life satisfaction, emotional well-being, and functioning of individuals. The aim of our study was to assess the quality of life of dental students at one U.S. dental school, using the World Health Organization Quality of Life (WHOQOL)-BREF, a multi-dimensional, cross-cultural, validated, and reliable survey instrument. Of the 1,437 students invited to participate, 401 students responded, but 17 were excluded because of missing data. The final sample consisted of 384 students for an overall response rate of 27%: response rates by year were first year 32.6%, second year 16.9%, third year 26.6%, and fourth year 24.0%. The results showed that the responding students rated their overall quality of life as good. The Physical Health domain had the highest mean score, while the Psychological domain had the lowest. Females reported higher quality of life than males in the Social Relationships domain. Single students were found to have a lower perceived quality of life than married students. Older students were found to have lower perceived quality of life in the Physical Health and Environment domains. Physical Health domain scores were significantly higher for fourth-year than first-year respondents, while Psychological domain scores were significantly lower for third-year than first-year respondents. Further research is needed to explore the effect of dental school on the quality of life of dental students. Targeted programs to impact students' quality of life at various points in the curriculum may be beneficial.

  11. Internal quality control of PCR-based genotyping methods

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  12. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson Intrastate Air Quality Control Region has been renamed the Maricopa Intrastate Air Quality Control Region... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Maricopa Intrastate Air Quality...

  13. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  14. Employment status matters: a statewide survey of quality-of-life, prevention behaviors, and absenteeism and presenteeism.

    Science.gov (United States)

    Merchant, James A; Kelly, Kevin M; Burmeister, Leon F; Lozier, Matt J; Amendola, Alison; Lind, David P; KcKeen, Arlinda; Slater, Tom; Hall, Jennifer L; Rohlman, Diane S; Buikema, Brenda S

    2014-07-01

    To estimate quality-of-life (QoL), primary care, health insurance, prevention behaviors, absenteeism, and presenteeism in a statewide sample of the unemployed, self-employed, and organizationally employed. A statewide survey of 1602 Iowans included items from the Centers for Disease Control and Prevention QoL and Behavioral Risk Factor Surveillance System Survey prevention behavior questionnaires used to assess employee well-being; their indicator results are related to World Health Organization's Health and Work Performance Questionnaire-derived absenteeism and presenteeism scores. The unemployed exhibited poorer QoL and prevention behaviors; the self-employed exhibited many better QoL scores due largely to better prevention behaviors than those employed by organizations. Higher QoL measures and more prevention behaviors are associated with lower absenteeism and lower presenteeism. Employment status is related to measures of well-being, which are also associated with absenteeism and presenteeism.

  15. Investigation of clinical conditions affecting quality control in a dental X-ray unit

    International Nuclear Information System (INIS)

    Akiyama, Hironori; Koseki, Takakazu; Itagaki, Keisuke; Yotsui, Yoritaka; Gamoh, Shoko; Shimizutani, Kimishige

    2011-01-01

    In this study, to clarify quality control issues in a dental X-ray unit, we surveyed the uniformity and safety of absorbed doses and exposure time from dental X-ray units, and evaluated image quality of intraoral radiography at Osaka Dental University Hospital. Measurements of dose and exposure time were carried out five times and the mean was calculated at twenty-two dental X-ray units in our university hospital using the standard parameters for the mandibular molar region in adults. Intraoral radiography for evaluation of image quality was taken using D-speed films under the standard parameters for the mandibular molar region in adults and E-speed films for pediatric patients. Evaluation of image quality was performed by three oral radiologists. Dose and exposure time differed significantly among units. Image quality of intraoral radiography using D-speed films was not significantly better than that of E-speed films. This study demonstrated that it is necessary to establish a uniform dose and exposure time and to change D-speed films to E-speed films when obtaining intraoral radiography in our hospital. (author)

  16. Role of monitoring network in the control management of air quality. An industrial case history

    Energy Technology Data Exchange (ETDEWEB)

    Zerbo, G. [Catania Univ. (Italy). Inst. of Merceology; Fabiano, B.; Ferraiolo, A.; Solisio, C.; Ruaro, R.

    1995-12-31

    Air quality control by a system of monitoring station is indispensable for the environmental protection. Moreover, a monitoring network have not to be only a mere data collection a good air quality control is possible only if the network management allows to prevent unacceptable pollutants level. In other terms, elaboration and interpretation data are fundamental in order to make monitoring system really able for regulations of corrective measures as, for example, the reduction of local emissions. The case of monitoring network run from the Industrial Society CIPA of Siracusa (Italy) is discussed. The management of the data obtained from a continuous survey allows to keep pollutants level below the current limits set down by the Italian law. Furthermore, elaboration of the data allows useful evaluations about atmospheric dispersion phenomena. (author)

  17. Role of monitoring network in the control management of air quality. An industrial case history

    Energy Technology Data Exchange (ETDEWEB)

    Zerbo, G [Catania Univ. (Italy). Inst. of Merceology; Fabiano, B; Ferraiolo, A; Solisio, C; Ruaro, R

    1996-12-31

    Air quality control by a system of monitoring station is indispensable for the environmental protection. Moreover, a monitoring network have not to be only a mere data collection a good air quality control is possible only if the network management allows to prevent unacceptable pollutants level. In other terms, elaboration and interpretation data are fundamental in order to make monitoring system really able for regulations of corrective measures as, for example, the reduction of local emissions. The case of monitoring network run from the Industrial Society CIPA of Siracusa (Italy) is discussed. The management of the data obtained from a continuous survey allows to keep pollutants level below the current limits set down by the Italian law. Furthermore, elaboration of the data allows useful evaluations about atmospheric dispersion phenomena. (author)

  18. Quality Control - Nike.Inc

    OpenAIRE

    Walter G. Bishop

    2017-01-01

    The purpose of this paper is to present the illustration of quality control approach, which has been adopted by several organizations, in order to manage and improve their production processes. The approach is referred as total quality management (TQM). This study will discuss the implementation of TQ, within the working environment of Nike Inc. One of the major objectives behind the implementation of TQ is to reduce or completely eliminate potential errors and flaws, within the manufacturing...

  19. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  20. Belief Control Practices and Organizational Performances: A Survey ...

    African Journals Online (AJOL)

    Belief Control Practices and Organizational Performances: A Survey of Sugar Industry in Kenya. ... employees in the company core values and design of strategic control systems to cope with changing internal and external operating business ...

  1. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  2. Quality control in urodynamics and the role of software support in the QC procedure.

    Science.gov (United States)

    Hogan, S; Jarvis, P; Gammie, A; Abrams, P

    2011-11-01

    This article aims to identify quality control (QC) best practice, to review published QC audits in order to identify how closely good practice is followed, and to carry out a market survey of the software features that support QC offered by urodynamics machines available in the UK. All UK distributors of urodynamic systems were contacted and asked to provide information on the software features relating to data quality of the products they supply. The results of the market survey show that the features offered by manufacturers differ greatly. Automated features, which can be turned off in most cases, include: cough recognition, detrusor contraction detection, and high pressure alerts. There are currently no systems that assess data quality based on published guidelines. A literature review of current QC guidelines for urodynamics was carried out; QC audits were included in the literature review to see how closely guidelines were being followed. This review highlights the fact that basic QC is not being carried out effectively by urodynamicists. Based on the software features currently available and the results of the literature review there is both the need and capacity for a greater degree of automation in relation to urodynamic data quality and accuracy assessment. Some progress has been made in this area and certain manufacturers have already developed automated cough detection. Copyright © 2011 Wiley Periodicals, Inc.

  3. Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

    Energy Technology Data Exchange (ETDEWEB)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika; Diamond, Kevin; Frenière, Normand; Grant, John; Pomerleau-Dalcourt, Natalie; Schella, Jason; Schreiner, L. John; Tantot, Laurent; Barajas, Eduardo Villareal; Sasaki, David; Milette, Marie-Pierre; Bertrand, Marie-Joëlle; Bissonnette, Jean-Pierre [Royal Victoria Hospital (Canada)

    2016-08-15

    The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

  4. Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

    International Nuclear Information System (INIS)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika; Diamond, Kevin; Frenière, Normand; Grant, John; Pomerleau-Dalcourt, Natalie; Schella, Jason; Schreiner, L. John; Tantot, Laurent; Barajas, Eduardo Villareal; Sasaki, David; Milette, Marie-Pierre; Bertrand, Marie-Joëlle; Bissonnette, Jean-Pierre

    2016-01-01

    The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

  5. 21 CFR 111.105 - What must quality control personnel do?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105..., LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must...

  6. The Study on quality control of nuclear power installation project

    International Nuclear Information System (INIS)

    Wu Jie

    2008-01-01

    The quality planning, quality assurance and quality control are discussed by applying the quality control (QC) theory and combining the real situation of the Qinshan II project. This paper is practical and plays an active role in instruction of project quality control by applying the above QC theory and control techniques. (authors)

  7. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    OpenAIRE

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  8. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  9. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    Science.gov (United States)

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Control of quality in mammography

    International Nuclear Information System (INIS)

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  11. The study on quality control of bedside CR examination

    International Nuclear Information System (INIS)

    Yang Xufeng; Luo Xiaomei; Xu Qiaolan; Wu Tengfang; Wen Xingwei

    2007-01-01

    Objective: To study the quality controll of bedside CR examination and improves the imaging quality. Methods: X-ray examination with CR system were performed on 3,300 patients. All CR cassettes were encoded. The imaging plate and cassettes were cleaned regularly. Results: With and without quality control, the percentage of first-rate film was 58.2% and 51%, the second-rate film was 40% and 45.5%, the third-rate film was 1.3% and 2%, respectively. Corxespondingly, the ratio of re-examination decreased from 1.5% to 0.5% after quality control, and imaging quality was stable. Conclusion: The quality control of bedside CR examination can improve the image quality as well as lighten the labor of radiographers. (authors)

  12. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    Science.gov (United States)

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  13. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate Air Quality Control Region (Oregon-Washington) has been revised to consist of the territorial area... Portland Interstate Air Quality Control Region (Oregon-Washington) will be referred to by Washington...

  14. Quality assurance in education: The role of ICT and quality control ...

    African Journals Online (AJOL)

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  15. Quality control of scintillation cameras (planar and SPECT)

    International Nuclear Information System (INIS)

    Shaekhoon, E.S.

    2008-01-01

    Regular quality control is one of the corner stones of nuclear medicine and a prerequisite for adequate diagnostic imaging. Many papers have been published on quality control of planar and SPECT imaging system up to now, however only minor attenuation has been given to the assessment of the performance of imaging systems. In this research we are going to discuss a comprehensive set of test procedures including regular quality control. Our purpose is to go through analysis of the methods and results then to test our hypothesis which state that there is strong relationship between regular and proper evaluation of quality control and the continuity of better medical services in nuclear medicine department. The selection of the tests is discussed and the tests are described, then results are presented. In addition action thresholds are proposed. The quality control tests can be applied to systems with either a moving detector or a moving image table, and to both detector with a large field of view and detectors with a small field of view. The tests presented on this research do not required special phantoms or sources other than those used for quality control of stationary gamma camera and SPECT. They can be applied for acceptance testing and for performance testing in a regular quality assurance program. The data has been evaluated based on me diso software in comparing with IAEA expert software and system specification within the reference values. Our final results confirm our hypothesis, there are some comments about the characteristics and performance of this system that being observed and solved, then a departmental protocol for routine quality control (Q.C) has being established.(Author)

  16. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  17. Health-related quality of life of immune thrombocytopenic purpura patients: results from a web-based survey.

    Science.gov (United States)

    Snyder, Claire F; Mathias, Susan D; Cella, David; Isitt, John J; Wu, Albert W; Young, Joan

    2008-10-01

    To assess the health-related quality of life (HRQOL) of immune thrombocytopenic purpura (ITP) patients. This was a cross-sectional, descriptive study comparing ITP patients' HRQOL to age and gender matched controls. ITP patients from the Platelet Disorder Support Association were recruited until 1000 surveys had been completed. Controls were randomly sampled from the Harris Interactive Online Panel. ITP patients and controls completed a one-time web-based survey, including a comprehensive HRQOL assessment. ITP patients completed the SF-36, the EQ-5D, and the ITP-Patient Assessment Questionnaire (ITP-PAQ). Controls completed the SF-36 and EQ-5D only. ITP patients' SF-36 and EQ-5D scores were compared to controls in unadjusted and adjusted analyses. Associations between splenectomy status, duration of illness, and platelet count with ITP patients' HRQOL scores were also examined. This analysis included 1002 ITP patients and 1031 controls. ITP patients scored worse on seven of eight SF-36 domains and the Physical and Mental Summary scores (all p PAQ scales: Bother, Psychological, Fear, Social Activity, and Work (all p PAQ scales. Lower platelet count was consistently associated with worse ITP-PAQ scores and had weaker associations with SF-36 and EQ-5D scores. ITP was associated with consistent and statistically significant deficits on generic HRQOL measures. The ITP-PAQ demonstrated differences based on disease severity and treatments. The self-selection bias in the two samples limits the generalizability of the results to all patients with ITP. Further research is needed in more generalizable samples.

  18. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  19. Ideology and Audit Culture: Standardized Service Quality Surveys in Academic Libraries

    Science.gov (United States)

    Lilburn, Jeff

    2017-01-01

    This article examines the relationship between the standardized service quality survey LibQUAL+ and the rise of audit culture. Recent scholarship examining assessment and accountability systems and the ideological principles driving their implementation in higher education raises concerns about the impact these systems have on teaching, learning,…

  20. Quality by control: Towards model predictive control of mammalian cell culture bioprocesses.

    Science.gov (United States)

    Sommeregger, Wolfgang; Sissolak, Bernhard; Kandra, Kulwant; von Stosch, Moritz; Mayer, Martin; Striedner, Gerald

    2017-07-01

    The industrial production of complex biopharmaceuticals using recombinant mammalian cell lines is still mainly built on a quality by testing approach, which is represented by fixed process conditions and extensive testing of the end-product. In 2004 the FDA launched the process analytical technology initiative, aiming to guide the industry towards advanced process monitoring and better understanding of how critical process parameters affect the critical quality attributes. Implementation of process analytical technology into the bio-production process enables moving from the quality by testing to a more flexible quality by design approach. The application of advanced sensor systems in combination with mathematical modelling techniques offers enhanced process understanding, allows on-line prediction of critical quality attributes and subsequently real-time product quality control. In this review opportunities and unsolved issues on the road to a successful quality by design and dynamic control implementation are discussed. A major focus is directed on the preconditions for the application of model predictive control for mammalian cell culture bioprocesses. Design of experiments providing information about the process dynamics upon parameter change, dynamic process models, on-line process state predictions and powerful software environments seem to be a prerequisite for quality by control realization. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    International Nuclear Information System (INIS)

    Saez, F.; Benito, M. A.; Collado, P.; Saez, M.

    2011-01-01

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  2. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    Science.gov (United States)

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  3. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  4. Quality assurance and product quality

    International Nuclear Information System (INIS)

    Lacroix, D.; Bastiani, P. de

    2004-01-01

    The basic quality assurance requirements have to be completed by means that are oriented towards the quality of products; in COGEMA LOGISTICS our approach is based on four principles: 1) an integrated management system: Quality, health and safety, environment 2) an organization based on the responsibility of all actors, trust and transparency 3) a methodical approach to continuously improve the methods that are employed to achieve quality: -process management -corrective and preventive actions -self assessments and various surveys 4) but at the same time strong procedures for control and monitoring of all activities: -technical and quality audits (external and internal) -at source inspections -engineering activities inspections This performance-based approach is necessary to guaranty the effectiveness of the traditional formal QA means

  5. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  6. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  7. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  8. Tools for surveying and improving the quality of life: people with special needs in focus.

    Science.gov (United States)

    Hoyningen-Süess, Ursula; Oberholzer, David; Stalder, René; Brügger, Urs

    2012-01-01

    This article seeks to describe online tools for surveying and improving quality of life for people with disabilities living in assisted living centers and special education service organizations. Ensuring a decent quality of life for disabled people is an important welfare state goal. Using well-accepted quality of life conceptions, online diagnostic and planning tools were developed during an Institute for Education, University of Zurich, research project. The diagnostic tools measure, evaluate and analyze disabled people's quality of life. The planning tools identify factors that can affect their quality of life and suggest improvements. Instrument validity and reliability are not tested according to the standard statistical procedures. This will be done at a more advanced stage of the project. Instead, the tool is developed, refined and adjusted in cooperation with practitioners who are constantly judging it according to best practice standards. The tools support staff in assisted living centers and special education service organizations. These tools offer comprehensive resources for surveying, quantifying, evaluating, describing and simulating quality of life elements.

  9. Tumor-resected kidney transplant – a quality of life survey

    Directory of Open Access Journals (Sweden)

    Sundararajan S

    2016-05-01

    Full Text Available Siva Sundararajan,1 Bulang He,1,2 Luc Delriviere,1,2 1WA Liver and Kidney Surgical Transplant Service, Department of General Surgery, Sir Charles Gairdner Hospital, Perth, WA, Australia; 2School of Surgery, The University of Western Australia, Perth, WA, Australia Background: To overcome the organ shortage, a program to use kidney grafts after excision of a small renal tumor (tumor resected kidney [TRK] was implemented in February 2007. All recipients were over 55 years old according to the selection criteria. The aim of this study is to assess the quality of life after kidney transplant in this cohort. Methods: From February 2007 to July 2013, 27 patients received a kidney graft after excision of the small kidney tumor. All patients were given the modified 36-Item Short Form Survey (SF-36 questionnaire with additional information regarding concerns about tumor recurrence and whether they would choose TRK transplantation or prefer to stay on dialysis if they have an option again. Results: Of them, 20 returned the completed questionnaire. There is no tumor recurrence on a mean follow-up of 38 months. The mean scores in all eight domains of the SF-36 were higher posttransplantation. The differences were statistically significant. Ninety-five percent of recipients would prefer to have TRK transplantation rather than remain on dialysis. Eighty percent of patients had no or minimal concerns regarding tumor recurrence. Conclusion: The patients who had kidney transplantation by using the graft after excision of a small tumor have achieved excellent quality of life. It is an important alternative for the solution of organ shortage in kidney transplantation. The concern of tumor recurrence is minimal. Performing a further study is worthwhile, with prospective data collection and a control group. Keywords: quality of life, kidney transplant, tumor, small renal cell carcinoma

  10. European quality assurance and quality control for cut-off walls and caps

    International Nuclear Information System (INIS)

    Jefferis, S.A.

    1997-01-01

    Cut-off walls and caps both may be seriously compromised by small areas of substandard materials or work. Quality assurance/quality control is therefore of crucial importance and the paper sets out the issues that need to be addressed when designing a quality plan for a containment. Consideration is given to the purpose of the containment, the parameters to be controlled, specifications and standards and tests on raw and manufactured materials and on the in-situ containment. It is not the purpose of the paper to give detailed test procedures but rather to identify the questions that must be answered to develop a quality plan

  11. Computer-supported quality control in X-ray diagnosis

    International Nuclear Information System (INIS)

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  12. Quality control of radiation therapy in clinical trials

    International Nuclear Information System (INIS)

    Kramer, S.; Lustig, R.; Grundy, G.

    1983-01-01

    The RTOG is a group of participating institutions which has a major interest in furthering clinical radiation oncology. They have formulated protocols for clinical investigation in which radiation therapy is the major modality of treatment. In addition, other modalities, such as chemotherapy, radiation sensitizers, and hyperthermia, are used in combined approach to cancer. Quality control in all aspects of patient management is necessary to insure quality data. These areas include evaluation of pathology, physics, and dosimetry, and clinical patient data. Quality control is both time consuming and expensive. However, by dividing these tasks into various levels and time frames, by using computerized data-control mechanisms, and by employing appropriate levels of ancillary personnel expertise, quality control can improve compliance and decrease the cost of investigational trials

  13. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each of these con......In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...

  14. Shipping/Receiving and Quality Control

    Data.gov (United States)

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  15. Quality control of the activity meter

    International Nuclear Information System (INIS)

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de

    2017-01-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  16. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  17. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Soni, P.S.

    1992-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  18. Children’s perception on obesity and quality of life: a Mexican survey

    OpenAIRE

    Rendón-Macías, Mario-Enrique; Rosas-Vargas, Haydeé; Villasís-Keever, Miguel-Ángel; Pérez-García, Celia

    2014-01-01

    Background Child obesity has become a major health problem worldwide. In order to design successful intervention strategies, it is necessary to understand how children perceive obesity and its consequences. Methods With the aim to evaluate scholar children perception of obesity as a significant factor on the quality of life, we developed and validated the “Obesity impact on the quality of life perception-questionnaire” (ObI-Q). We surveyed 1335 healthy children aged 6–12 years, randomly selec...

  19. Sleep Quality and Health-Related Quality of Life in Pregnancy.

    Science.gov (United States)

    Sut, Hatice Kahyaoglu; Asci, Ozlem; Topac, Nalan

    The aim of this study was to investigate sleep quality and health-related quality of life in pregnancy. In a cross-sectional design, 492 women (292 pregnant and 200 nonpregnant healthy controls) were included in this study between November 2014 and June 2015. Participants completed a survey on sociodemographic characteristics, the Pittsburgh Sleep Quality Index (PSQI), and the European Quality of Life-5 Dimensions (EQ-5D). The PSQI total and EQ-5D scores of pregnant women were significantly worse than the controls (P = .017 and P sleep quality increased 2.11-fold in the second trimester (P = .048) and 1.86-fold in the third trimester (P = .054). Compared with the first trimester, EQ-5D scores significantly decreased in the second (P = .038) and third (P Sleep quality and health-related quality of life of pregnant women were worse than those of nonpregnant healthy controls. Healthcare professionals need to be aware of deteriorations in sleep quality and health-related quality of life of pregnant women.

  20. The Influence of the Design of Web Survey Questionnaires on the Quality of Responses

    Directory of Open Access Journals (Sweden)

    Stéphane Ganassali

    2008-03-01

    Full Text Available he first objective of this article is to propose a conceptual framework of the effects of on-line questionnaire design on the quality of collected responses. Secondly, we present the results of an experiment where different protocols have been tested and compared in a randomised design using the basis of several quality indexes. Starting from some previous categorizations, and from the main factors identified in the literature, we first propose an initial global framework of the questionnaire and question characteristics in a web survey, divided into five groups of factors. Our framework was built to follow the response process successive stages of the contact between the respondent and the questionnaire itself. Then, because it has been studied in the survey methodology literature in a very restricted way, the concept of `response quality' is discussed and extended with some more `qualitative' criteria that could be helpful for researchers and practitioners, in order to obtain a deeper assessment of the survey output. As an experiment, on the basis of the factors chosen as major characteristics of the questionnaire design, eight versions of a questionnaire related to young people's consumption patterns were created. The links to these on-line questionnaires were sent in November 2005 to a target of 10,000 young people. The article finally presents the results of our study and discusses the conclusions. Very interesting results come to light; especially regarding the influence of length, interaction and question wording dimensions on response quality. We discuss the effects of Web-questionnaire design characteristics on the quality of data.

  1. Sleep Duration and Quality in Pregnant Women: A Cross-Sectional Survey in China

    Directory of Open Access Journals (Sweden)

    Xianglong Xu

    2017-07-01

    Full Text Available Objectives: Good maternal health and fetal development require sufficient and good quality of sleep during pregnancy. This study investigated sleep duration and quality in pregnant women, assessing factors with possibly influence on sleep. Method: A cross-sectional survey was conducted on pregnant women between June and August in 2015 in 16 hospitals in five provinces in China. A total of 2345 pregnant women aged 18 years and older were surveyed. Insufficient sleeping duration was defined as sleeping of less than 7 h per day. Excessive sleep duration was defined as sleeping of more than 9 h per day. Results: A total of 561 (23.9% participants reported insufficient sleeping duration, whereas 485 (20.9% claimed excessive sleep duration. A total of 358 (15.2% of pregnant women reported problems regarding sleep quality. Compared to pregnant women with sufficient sleeping duration, those with insufficient sleeping duration were prone to have poor sleep quality, whereas those with excessive sleeping duration featured low possibility of poor sleep quality. High-risk groups of insufficient sleep duration include women of Han nationality, with siblings, in their first trimester of pregnancy, receiving care in low-capacity/quality hospital settings, and with daily or 1–3 days of secondhand smoke exposure. High-risk groups of excessive sleep duration include women living in rural areas, unemployed, in their third trimester of pregnancy, and receiving care in medium-capacity/quality hospital settings. High-risk groups of poor sleep quality include women of non-Han nationality, low income level, in their third trimester of pregnancy, and with insufficient sleep duration. Conclusions: Insufficient/excessive sleep duration and poor sleep quality commonly occur during pregnancy in China. Findings provide a better understanding of the influencing factors of insufficient/excessive sleep duration and poor quality of sleep. These findings have some implications

  2. Locus of control, quality of life, anxiety, and depression among Malaysian breast cancer patients: The mediating role of uncertainty.

    Science.gov (United States)

    Pahlevan Sharif, Saeed

    2017-04-01

    The main objective of this study was to investigate the mediating role of uncertainty in the relationship between locus of control with quality of life, anxiety, and depression. A descriptive and correlational survey was conducted in a private hospital in Kuala Lumpur, Malaysia. A convenience sample of 118 Malaysian breast cancer patients voluntarily participated in the study and responded to a set of questionnaires including: socio-demographic questionnaire, the short form of Locus of Control Scale, the Functional Assessment of Cancer Therapy-Breast (FACT-B), the Hospital Anxiety and Depression Scale (HADS), and the Short-Form Mishel Uncertainty in Illness Scale (SF-MUIS). The results revealed that breast cancer patients with higher internal locus of control and lower external locus of control experience a higher quality of life, lower anxiety, and lower depression. Also, uncertainty mediated the relationship between locus of control with quality of life and depression (quasi-significant). The findings indicated the need for early, targeted psychological interventions seeking to gradually shift cancer patients' locus of control from external to internal in order to improve their quality of life and reduce their depression and anxiety. Moreover, health care providers by providing relevant information to cancer patients, especially for externally oriented patients, can reduce their uncertainty which in turn would improve their quality of life. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  4. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  5. Web quality control for lectures: Supercourse and Amazon.com.

    Science.gov (United States)

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  6. 40 CFR 81.111 - Georgetown Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.111 Georgetown Intrastate Air Quality Control Region. The Georgetown Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Georgetown Intrastate Air Quality...

  7. 40 CFR 81.107 - Greenwood Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.107 Greenwood Intrastate Air Quality Control Region. The Greenwood Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Greenwood Intrastate Air Quality...

  8. 40 CFR 81.108 - Columbia Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.108 Columbia Intrastate Air Quality Control Region. The Columbia Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Columbia Intrastate Air Quality...

  9. 40 CFR 81.109 - Florence Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.109 Florence Intrastate Air Quality Control Region. The Florence Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Florence Intrastate Air Quality...

  10. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville Interstate Air Quality Control Region (Kentucky-Indiana) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Louisville Interstate Air Quality...

  11. AAN Epilepsy Quality Measures in clinical practice: a survey of neurologists.

    Science.gov (United States)

    Wasade, Vibhangini S; Spanaki, Marianna; Iyengar, Revathi; Barkley, Gregory L; Schultz, Lonni

    2012-08-01

    Epilepsy Quality Measures (EQM) were developed by the American Academy of Neurology (AAN) to convey standardization and eliminate gaps and variations in the delivery of epilepsy care (Fountain et al., 2011 [1]). The aim of this study was to identify adherence to these measures and other emerging practice standards in epilepsy care. A 15-item survey was mailed to neurologists in Michigan, USA, inquiring about their practice patterns in relation to EQM. One hundred thirteen of the 792 surveyed Michigan Neurologists responded (14%). The majority (83% to 94%) addressed seizure type and frequency, reviewed EEG and MRI, and provided pregnancy counseling to women of childbearing potential. Our survey identified gaps in practice patterns such as counseling about antiepileptic drug (AED) side effects and knowledge about referral for surgical therapy of intractable epilepsy. Statistical significance in the responses on the AAN EQM was noted in relation to number of years in practice, number of epilepsy patients seen, and additional fellowship training in epilepsy. Practice patterns assessment in relation to other comorbidities revealed that although bone health and sudden unexplained death in epilepsy are addressed mainly in patients at risk, depression is infrequently discussed. The findings in this study indicate that additional educational efforts are needed to increase awareness and to improve quality of epilepsy care at various points of health care delivery. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Perceived neighborhood quality, sleep quality, and health status: evidence from the Survey of the Health of Wisconsin.

    Science.gov (United States)

    Hale, Lauren; Hill, Terrence D; Friedman, Elliot; Nieto, F Javier; Galvao, Loren W; Engelman, Corinne D; Malecki, Kristen M C; Peppard, Paul E

    2013-02-01

    Why does living in a disadvantaged neighborhood predict poorer mental and physical health? Recent research focusing on the Southwestern United States suggests that disadvantaged neighborhoods favor poor health, in part, because they undermine sleep quality. Building on previous research, we test whether this process extends to the Midwestern United States. Specifically, we use cross-sectional data from the Survey of the Health of Wisconsin (SHOW), a statewide probability sample of Wisconsin adults, to examine whether associations among perceived neighborhood quality (e.g., perceptions of crime, litter, and pleasantness in the neighborhood) and health status (overall self-rated health and depression) are mediated by overall sleep quality (measured as self-rated sleep quality and physician diagnosis of sleep apnea). We find that perceptions of low neighborhood quality are associated with poorer self-rated sleep quality, poorer self-rated health, and more depressive symptoms. We also observe that poorer self-rated sleep quality is associated with poorer self-rated health and more depressive symptoms. Our mediation analyses indicate that self-rated sleep quality partially mediates the link between perceived neighborhood quality and health status. Specifically, self-rated sleep quality explains approximately 20% of the association between neighborhood quality and self-rated health and nearly 19% of the association between neighborhood quality and depression. Taken together, these results confirm previous research and extend the generalizability of the indirect effect of perceived neighborhood context on health status through sleep quality. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Survey of orbital dynamics and control of space rendezvous

    Directory of Open Access Journals (Sweden)

    Luo Yazhong

    2014-02-01

    Full Text Available Rendezvous orbital dynamics and control (RODC is a key technology for operating space rendezvous and docking missions. This paper surveys the studies on RODC. Firstly, the basic relative dynamics equation set is introduced and its improved versions are evaluated. Secondly, studies on rendezvous trajectory optimization are commented from three aspects: the linear rendezvous, the nonlinear two-body rendezvous, and the perturbed and constrained rendezvous. Thirdly, studies on relative navigation are briefly reviewed, and then close-range control methods including automated control, manual control, and telecontrol are analyzed. Fourthly, advances in rendezvous trajectory safety and robust analysis are surveyed, and their applications in trajectory optimization are discussed. Finally, conclusions are drawn and prospects of studies on RODC are presented.

  14. [Pharmaceutical product quality control and good manufacturing practices].

    Science.gov (United States)

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  15. Developing a Continuous Quality Improvement Assessment Using a Patient-Centered Approach in Optimizing Systemic Lupus Erythematosus Disease Control.

    Science.gov (United States)

    Updyke, Katelyn Mariko; Urso, Brittany; Beg, Shazia; Solomon, James

    2017-10-09

    Systemic lupus erythematosus (SLE) is a multi-organ, autoimmune disease in which patients lose self-tolerance and develop immune complexes which deposit systemically causing multi-organ damage and inflammation. Patients often experience unpredictable flares of symptoms with poorly identified triggers. Literature suggests exogenous exposures may contribute to flares in symptoms. An online pilot survey was marketed globally through social media to self-reported SLE patients with the goal to identify specific subpopulations who are susceptible to disease state changes based on analyzed exogenous factors. The pilot survey was promoted for two weeks, 80 respondents fully completed the survey and were included in statistical analysis. Descriptive statistical analysis was performed on de-identified patient surveys and compared to previous literature studies reporting known or theorized triggers in the SLE disease state. The pilot survey identified similar exogenous triggers compared to previous literature, including antibiotics, increasing beef intake, and metal implants. The goal of the pilot survey is to utilize similar questions to develop a detailed internet-based patient interactive form that can be edited and time stamped as a method to promote continuous quality improvement assessments. The ultimate objective of the platform is to interact with SLE patients from across the globe longitudinally to optimize disease control and improve quality of care by allowing them to avoid harmful triggers.

  16. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  17. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga Interstate Air Quality Control Region (Georgia-Tennessee) has been revised to consist of the territorial area... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Chattanooga Interstate Air Quality...

  18. Quality control activities in the environmental radiology laboratory

    International Nuclear Information System (INIS)

    Llaurado, M.; Quesada, D.; Rauret, G.; Tent, J.; Zapata, D.

    2006-01-01

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  19. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  20. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  1. Quality control procedures in positron tomography

    International Nuclear Information System (INIS)

    Spinks, T.; Jones, T.; Heather, J.; Gilardi, M.

    1989-01-01

    The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given data. This provides the raw data from which decisions on recalibration or renormalisation are made. (orig.)

  2. 21 CFR 862.1660 - Quality control material (assayed and unassayed).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control material (assayed and unassayed... Test Systems § 862.1660 Quality control material (assayed and unassayed). (a) Identification. A quality... that may arise from reagent or analytical instrument variation. A quality control material (assayed and...

  3. A survey study comparing young adults with MS and healthy controls on self-esteem, self-efficacy, mood and quality of life.

    Science.gov (United States)

    Messmer Uccelli, Michele; Traversa, Silvia; Ponzio, Michela

    2016-09-15

    Studies have shown that people with multiple sclerosis (MS) report low levels of self-efficacy and self-esteem, high levels of anxiety and depression and reduced quality of life. The study aims to assess self-esteem, self-efficacy, mood and quality of life in young adults with MS and to compare them to a healthy control group. The age range for inclusion in the study was between 18 and 35years of age for both groups. Subjects with MS were recruited through the Italian MS Society. Healthy controls were recruited through social media and from a university undergraduate program. Subjects completed an anonymous online questionnaire combining various scales. Group differences on demographic data were assessed using parametric and non-parametric tests. Analyses of covariance (ANCOVA) were performed to evaluate differences between the two groups on scales of self-perception, mood and quality of life, adjusting for potentially confounding factors. Eighty-nine subjects with MS and 109 HC were included in the analysis. ANCOVA failed to demonstrate statistically significant differences between groups on self-esteem (F=0.11, p=0.743), self-efficacy (F=2.22, p=0.138), mood (anxiety F=0.03, p=0.855; depression F=0.06, p=0.812) and quality of life (F=0.08, p=0.772). This study demonstrated that young adults with MS and healthy controls have similar levels of self-esteem and self-efficacy and that they do not differ significantly on measures of mood and quality of life, as previously reported. Copyright © 2016. Published by Elsevier B.V.

  4. Skeletal survey quality in non-accidental injury – A single site evaluation of the effects of imaging checklists

    International Nuclear Information System (INIS)

    Weldon, J.; Price, R.

    2016-01-01

    Aims: Evidence suggests ongoing practice variability in the quality of skeletal survey examinations for non-accidental injury. The purpose of the study was to investigate the effects on examination quality following the implementation of imaging checklists. Method: A retrospective evaluation of skeletal survey examinations was carried out on studies performed between January 2007 and November 2014 at a large District General Hospital Trust. Longitudinal assessment was undertaken over three periods, before and following the introduction of two versions of imaging checklists, following modifications. Examinations were assessed and scored using three measures for completeness and quality employing a modified established scoring system against a professional body national standards document. Results: A total of 121 examinations met the inclusion criteria, all quality assessment measures showed improvements between each period. Examination completeness increased from median of 13 projections, to 20 throughout the three periods. Mann Whitney u Tests showed significant differences between each period. The mean combined anatomy score reduced from 3.11 to 1.10 throughout the three periods. Independent t Tests and Mann Whitney u Tests showed a significant decrease throughout the study period. Total percentage examination quality increased from median 44–83% throughout the three periods. Independent t Tests also showed significant differences between each period. Conclusion: The use of imaging checklists to improve quality and to support the optimal acquisition of the non-accidental injury skeletal survey shows encouraging results. However, further work is needed to optimise content and the use of checklists in practice. - Highlights: • Skeletal survey examinations for non-accidental practices have been shown to vary in content and in quality. • Checklists have demonstrated improvements in compliance to guidelines across health disciplines and in various settings.

  5. The quality of sample surveys in a developing nation

    Directory of Open Access Journals (Sweden)

    Paul A Bourne

    2010-08-01

    Full Text Available Paul A Bourne1, Christopher AD Charles2,3, Neva South-Bourne4, Chloe Morris1, Denise Eldemire-Shearer1, Maureen D Kerr-Campbell51Department of Community Health and Psychiatry, Faculty of Medical Sciences, University of the West Indies, Mona, Kingston, Jamaica; 2King Graduate School, Monroe College, Bronx, New York, USA; 3Center for Victim Support, Harlem Hospital Center, New York, USA; 4Research assistant for Paul A Bourne; 5Systems Development Unit, Main Library, Faculty of Humanities and Education, University of the West Indies, Mona, Kingston, JamaicaBackground: In Jamaica, population census began in 1844, and many intercensal ratios obtained from the census data showed that there is a general high degree of accuracy of the data. However, statistics from the Jamaican Ministry of Health showed that there are inaccuracies in health data collected from males using sample surveys.Objectives: The objectives of the present research are to 1 investigate the accuracy of a national sample survey, 2 explore the feasibility and quality of using a subnational sample survey to represent a national survey, 3 aid other scholars in understanding the probability of using national sample surveys and subnational sample surveys, 4 assess older men’s ­evaluation of their health status, and 5 determine whether dichotomization changes self-evaluated health status.Methods: For the current study, the data used in the analysis were originally collected from 2 different sources: 1 the Jamaica Survey of Living Conditions (JSLC and 2 Survey of Older Men (SOM. Cross validation of self-evaluated data of men in Jamaica was done with comparable samples of the complete JSLC data and the SOM data, where men older than 55 years were selected from each sample.Results: In study 1, 50.2% of respondents indicated at least good self-evaluated health status compared with 74.0% in study 2. Statistical associations were found between health status and survey sample (Χ2 [df = 5

  6. A survey of medical quality assurance programs in Ontario hospitals.

    OpenAIRE

    Barrable, B

    1992-01-01

    OBJECTIVE: To determine the prevalence and types of medical quality assurance practices in Ontario hospitals. DESIGN: Survey. SETTING: All teaching, community, chronic care, rehabilitation and psychiatric hospitals that were members of the Ontario Hospital Association as of May 1990. PARTICIPANTS: The person deemed by the chief executive officer of each hospital to be most responsible for medical administration. INTERVENTION: A questionnaire to obtain information on each hospital's use of cri...

  7. Performance of mechanical ventilators at the patient's home: a multicentre quality control study.

    Science.gov (United States)

    Farré, R; Navajas, D; Prats, E; Marti, S; Guell, R; Montserrat, J M; Tebe, C; Escarrabill, J

    2006-05-01

    Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.

  8. A SURVEY OF THE MICROBIOLOGICAL QUALITY OF WATER USED IN DENTAL TREATMENT

    Science.gov (United States)

    In recent years there has been a growing awareness of the microbiological quality of water used in dental water systems. The purpose of this study was to conduct a microbiological survey of dental water units within the Commonwealth of Kentucky. Water samples were collected and ...

  9. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1989-01-01

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author) [pt

  10. [Post-marketing reevaluation for potential quality risk and quality control in clinical application of traditional Chinese medicines].

    Science.gov (United States)

    Li, Hong-jiao; He, Li-yun; Liu, Bao-yan

    2015-06-01

    The effective quality control in clinical practices is an effective guarantee for the authenticity and scientificity of the findings. The post-marketing reevaluation for traditional Chinese medicines (TCM) focuses on the efficacy, adverse reaction, combined medication and effective dose of drugs in the market by expanded clinical trials, and requires a larger sample size and a wider range of patients. Therefore, this increases the difficulty of quality control in clinical practices. With the experience in quality control in clinical practices for the post-marketing reevaluation for Kangbingdu oral for cold, researchers in this study reviewed the study purpose, project, scheme design and clinical practice process from an overall point of view, analyzed the study characteristics of the post-marketing reevaluation for TCMs and the quality control risks, designed the quality control contents with quality impacting factors, defined key review contents and summarized the precautions in clinical practices, with the aim to improve the efficiency of quality control of clinical practices. This study can provide reference to clinical units and quality control-related personnel in the post-marketing reevaluation for TCMs.

  11. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  12. Reporting Quality of Randomized, Controlled Trials Evaluating Combined Chemoradiotherapy in Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Chen, Yu-Pei; Chen, Lei; Li, Wen-Fei; Lee, Anne W.M.; Vermorken, Jan B.; Wee, Joseph; O'Sullivan, Brian; Eisbruch, Avraham; Lin, Jin-Ching; Mai, Hai-Qiang; Zhang, Li; Guo, Ying; Lin, Ai-Hua; Sun, Ying

    2017-01-01

    Purpose: To comprehensively assess the reporting quality of randomized, controlled trials (RCTs) in nasopharyngeal carcinoma (NPC), and to identify significant predictors of quality. Methods and Materials: Two investigators searched MEDLINE and EMBASE for RCTs published between January 1988 and December 2015 that assessed the effect of combined chemoradiotherapy for NPC. The overall quality of each report was assessed using a 28-point overall quality score (OQS) based on the 2010 Consolidated Standards of Reporting Trials (CONSORT) statement. To provide baseline data for further evaluation, we also investigated the reporting quality of certain important issues in detail, including key methodologic items (allocation concealment, blinding, intention-to-treat principle), endpoints, follow-up, subgroup analyses, and adverse events. Results: We retrieved 24 relevant RCTs including 6591 patients. Median 2010 OQS was 15.5 (range, 10-24). Half of the items in the 2010 OQS were poorly reported in at least 40% of trials. Multivariable regression models revealed that publication after 2010 and high impact factor were significant predictors of improved 2010 OQS. Additionally, many issues that we consider significant were not reported adequately. Conclusions: Despite publication of the CONSORT statement more than a decade ago, overall reporting quality for RCTs in NPC was unsatisfactory. Additionally, substantial selectivity and heterogeneity exists in reporting of certain crucial issues. This survey provides the first prompt for NPC trial investigators to improve reporting quality according to the CONSORT statement; increased scrutiny and diligence by editors and peer reviewers is also required.

  13. Reporting Quality of Randomized, Controlled Trials Evaluating Combined Chemoradiotherapy in Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yu-Pei; Chen, Lei; Li, Wen-Fei [Department of Radiation Oncology, Sun Yat-sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre of Cancer Medicine, Guangzhou (China); Lee, Anne W.M. [Department of Clinical Oncology, The University of Hong Kong-Shenzhen Hospital, Shenzhen (China); Vermorken, Jan B. [Department of Medical Oncology, Antwerp University Hospital, Edegem (Belgium); Wee, Joseph [Department of Radiation Oncology, National Cancer Centre Singapore (Singapore); O' Sullivan, Brian [Department of Radiation Oncology, University of Toronto, Ontario Cancer Institute, University Health Network, Toronto, Ontario (Canada); Eisbruch, Avraham [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Lin, Jin-Ching [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China); Mai, Hai-Qiang [Department of Nasopharyngeal Carcinoma, Sun Yat-sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre of Cancer Medicine, Guangzhou (China); Zhang, Li [Department of Medical Oncology, Sun Yat-sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre of Cancer Medicine, Guangzhou (China); Guo, Ying [Clinical Trials Centre, Sun Yat-sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre of Cancer Medicine, Guangzhou (China); Lin, Ai-Hua [Department of Medical Statistics and Epidemiology, School of Public Health, Sun Yat-sen University, Guangzhou (China); Sun, Ying [Department of Radiation Oncology, Sun Yat-sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre of Cancer Medicine, Guangzhou (China); and others

    2017-05-01

    Purpose: To comprehensively assess the reporting quality of randomized, controlled trials (RCTs) in nasopharyngeal carcinoma (NPC), and to identify significant predictors of quality. Methods and Materials: Two investigators searched MEDLINE and EMBASE for RCTs published between January 1988 and December 2015 that assessed the effect of combined chemoradiotherapy for NPC. The overall quality of each report was assessed using a 28-point overall quality score (OQS) based on the 2010 Consolidated Standards of Reporting Trials (CONSORT) statement. To provide baseline data for further evaluation, we also investigated the reporting quality of certain important issues in detail, including key methodologic items (allocation concealment, blinding, intention-to-treat principle), endpoints, follow-up, subgroup analyses, and adverse events. Results: We retrieved 24 relevant RCTs including 6591 patients. Median 2010 OQS was 15.5 (range, 10-24). Half of the items in the 2010 OQS were poorly reported in at least 40% of trials. Multivariable regression models revealed that publication after 2010 and high impact factor were significant predictors of improved 2010 OQS. Additionally, many issues that we consider significant were not reported adequately. Conclusions: Despite publication of the CONSORT statement more than a decade ago, overall reporting quality for RCTs in NPC was unsatisfactory. Additionally, substantial selectivity and heterogeneity exists in reporting of certain crucial issues. This survey provides the first prompt for NPC trial investigators to improve reporting quality according to the CONSORT statement; increased scrutiny and diligence by editors and peer reviewers is also required.

  14. MDEP VICWG-02 Technical Report - Survey on quality assurance program requirements

    International Nuclear Information System (INIS)

    2011-01-01

    The survey was prepared using the requirements of Appendix B to 10 CFR Part 50, 'Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants'. These requirements form the basis upon which the U.S. NRC oversees the activities of vendors providing parts and services to the commercial U.S. nuclear power industry. As discussed and agreed to at the October 2008 Vendor Inspection Cooperation Working Group meeting in Dijon, France, the survey that follows was developed using these requirements. The survey is divided into the 18 basic criteria of Appendix B to 10 CFR Part 50. Within each criteria there are individual requirements that have been identified as separate and distinct elements that are covered during the inspection of vendor activities. In addition to the requirements of Appendix B to 10 CFR Part 50, the requirements of 10 CFR Part 21, 'Reporting of Defects and Non-compliance', have been listed at the end of the survey as an example of 'Other Requirements Related To Vendor Inspections', for the NRC. (authors)

  15. 40 CFR 81.104 - Central Pennsylvania Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.104 Section 81.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.104 Central Pennsylvania Intrastate Air Quality Control Region. The Central Pennsylvania Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  16. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.43 Section 81.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  17. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.31 Section 81.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  18. 40 CFR 81.90 - Androscoggin Valley Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.90 Section 81.90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.90 Androscoggin Valley Interstate Air Quality Control Region. The Androscoggin Valley Interstate Air Quality Control Region (Maine-New Hampshire) consists of the territorial...

  19. 40 CFR 81.78 - Metropolitan Portland Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.78 Section 81.78 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.78 Metropolitan Portland Intrastate Air Quality Control Region. The Metropolitan Portland Intrastate Air Quality Control Region (Maine) consists of the territorial area...

  20. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.30 Section 81.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  1. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.16 Section 81.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  2. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.47 Section 81.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  3. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION... Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control Region. The Metropolitan Indianapolis Intrastate Air Quality Control Region consists of the territorial...

  4. 40 CFR 81.101 - Metropolitan Dubuque Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.101 Section 81.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.101 Metropolitan Dubuque Interstate Air Quality Control Region. The Metropolitan Dubuque Interstate Air Quality Control Region (Illinois-Iowa-Wisconsin) consists of the...

  5. 40 CFR 81.79 - Northeastern Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.79 Section 81.79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.79 Northeastern Oklahoma Intrastate Air Quality Control Region. The Metropolitan Tulsa Intrastate Air Quality Control Region has been renamed the Northeastern Oklahoma Intrastate...

  6. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.24 Section 81.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  7. 40 CFR 81.106 - Greenville-Spartanburg Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.106 Section 81.106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.106 Greenville-Spartanburg Intrastate Air Quality Control Region. The Greenville-Spartanburg Intrastate Air Quality Control Region (South Carolina) consists of the territorial...

  8. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.44 Section 81.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  9. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.19 Section 81.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  10. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.28 Section 81.28 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  11. 40 CFR 81.119 - Western Tennessee Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.119 Section 81.119 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.119 Western Tennessee Intrastate Air Quality Control Region. The Western Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  12. 40 CFR 81.89 - Metropolitan Cheyenne Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.89 Section 81.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.89 Metropolitan Cheyenne Intrastate Air Quality Control Region. The Metropolitan Cheyenne Intrastate Air Quality Control Region (Wyoming) consists of the territorial area...

  13. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.87 Section 81.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area encompassed...

  14. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.23 Section 81.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  15. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.75 Section 81.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  16. 40 CFR 81.120 - Middle Tennessee Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.120 Section 81.120 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.120 Middle Tennessee Intrastate Air Quality Control Region. The Middle Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  17. Strapdown Airborne Gravimetry Quality Assessment Method Based on Single Survey Line Data: A Study by SGA-WZ02 Gravimeter

    Science.gov (United States)

    Wu, Meiping; Cao, Juliang; Zhang, Kaidong; Cai, Shaokun; Yu, Ruihang

    2018-01-01

    Quality assessment is an important part in the strapdown airborne gravimetry. Root mean square error (RMSE) evaluation method is a classical way to evaluate the gravimetry quality, but classical evaluation methods are preconditioned by extra flight or reference data. Thus, a method, which is able to largely conquer the premises of classical quality assessment methods and can be used in single survey line, has been developed in this paper. According to theoretical analysis, the method chooses the stability of two horizontal attitude angles, horizontal specific force and vertical specific force as the determinants of quality assessment method. The actual data, collected by SGA-WZ02 from 13 flights 21 lines in certain survey, was used to build the model and elaborate the method. To substantiate the performance of the quality assessment model, the model is applied in extra repeat line flights from two surveys. Compared with internal RMSE, standard deviation of assessment residuals are 0.23 mGal and 0.16 mGal in two surveys, which shows that the quality assessment method is reliable and stricter. The extra flights are not necessary by specially arranging the route of flights. The method, summarized from SGA-WZ02, is a feasible approach to assess gravimetry quality using single line data and is also suitable for other strapdown gravimeters. PMID:29373535

  18. Manual on quality assurance for the survey, evaluation and confirmation of nuclear power plant sites

    International Nuclear Information System (INIS)

    1987-04-01

    The present Manual on Quality Assurance for the Survey, Evaluation and Confirmation of Nuclear Power Plant Sites contains supporting material and illustrates examples for implementing the requirements contained in the Code of Practice on Quality Assurance for Safety in Nuclear Power Plants to the activities of survey, evaluation and confirmation of nuclear power plant sites. At the same time the Code of Practice for Safety in Nuclear Power Plant Siting, and Safety Guides in the siting series contain requirements and recommendations to implement a quality assurance programme in selected activities of the siting process. This manual is intended to provide guidance and illustrate examples on this implementation. During preparation and reviews of this Manual it was found out that the methodology of implementation of the quality assurance programme in siting activities is still under development. For these reasons it was considered appropriate to publish this Manual as a temporary publication for trial use

  19. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  20. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  1. Quality control for diagnostic oral microbiology laboratories in European countries

    Directory of Open Access Journals (Sweden)

    Andrew J. Smith

    2011-11-01

    Full Text Available Participation in diagnostic microbiology internal and external quality control (QC processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into the study and six laboratories from six European countries completed both the online survey and the first QC round. Three additional laboratories participated in the second round. Based on the survey, European oral microbiology laboratories process a significant (mean per laboratory 4,135 number of diagnostic samples from the oral cavity annually. A majority of the laboratories did not participate in any internal or external QC programme and nearly half of the laboratories did not have standard operating procedures for the tests they performed. In both QC rounds, there was a large variation in the results, interpretation and reporting of antibiotic susceptibility testing among the laboratories. In conclusion, the results of this study demonstrate the need for harmonisation of laboratory processing methods and interpretation of results for oral microbiology specimens. The QC rounds highlighted the value of external QC in evaluating the efficacy and safety of processes, materials and methods used in the laboratory. The use of standardised methods is also a prerequisite for multi-centre epidemiological studies that can provide important information on emerging microbes and trends in anti-microbial susceptibility for empirical prescribing in oro-facial infections.

  2. Implementing self sustained quality control procedures in a clinical laboratory.

    Science.gov (United States)

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  3. TL dosimetry for quality control of CR mammography imaging systems

    Science.gov (United States)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  4. 40 CFR 81.117 - Southeast Missouri Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.117 Section 81.117 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.117 Southeast Missouri Intrastate Air Quality Control Region. The Southeast Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  5. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.45 Section 81.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  6. 40 CFR 81.123 - Southeastern Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.123 Section 81.123 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.123 Southeastern Oklahoma Intrastate Air Quality Control Region. The Southeastern Oklahoma Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  7. 40 CFR 81.98 - Burlington-Keokuk Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.98 Section 81.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.98 Burlington-Keokuk Interstate Air Quality Control Region. The Burlington-Keokuk Interstate Air Quality Control Region (Illinois-Iowa) is revised to consist of the...

  8. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.49 Section 81.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  9. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.59 Section 81.59 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  10. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.20 Section 81.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  11. 40 CFR 81.97 - Southwest Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.97 Section 81.97 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.97 Southwest Florida Intrastate Air Quality Control Region. The Southwest Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  12. 40 CFR 81.116 - Northern Missouri Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.116 Section 81.116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.116 Northern Missouri Intrastate Air Quality Control Region. The Northern Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  13. 40 CFR 81.67 - Lake Michigan Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.67 Lake Michigan Intrastate Air Quality Control Region. The Menominee-Escanaba (Michigan)-Marinette (Wisconsin) Interstate Air Quality Control Region has been renamed the Lake Michigan Intrastate Air Quality Control Region (Wisconsin) and revised to consist of the territorial area...

  14. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.34 Section 81.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  15. 40 CFR 81.115 - Northwest Nevada Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.115 Section 81.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.115 Northwest Nevada Intrastate Air Quality Control Region. The Northwest Nevada Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  16. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.41 Section 81.41 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  17. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.14 Section 81.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  18. 40 CFR 81.118 - Southwest Missouri Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.118 Section 81.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.118 Southwest Missouri Intrastate Air Quality Control Region. The Southwest Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  19. 40 CFR 81.122 - Mississippi Delta Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.122 Section 81.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.122 Mississippi Delta Intrastate Air Quality Control Region. The Mississippi Delta Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  20. CONCRETE STRUCTURES' QUALITY CONTROL IN PRACTICE

    OpenAIRE

    Dolaček-Alduk, Zlata; Blanda, Miroslav

    2011-01-01

    The Croatian civil engineering is characterized by a lack of systematic approach to planning, control and quality assurance in all phases of project realization. The results obtained in establishing the quality management system in some segments of civil engineering production represent initial trends in solving this problem. Benefits are of two types: the achievement of quality for the contractor and obtaining that quaity is being achieved for clients. Execution of concrete structures is a c...

  1. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  2. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  3. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  4. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.48 Section 81.48 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of the...

  5. Concept and realization of quality control in FRG

    International Nuclear Information System (INIS)

    Odoj, R.; Martens, B.R.; Warnecke, E.

    1987-01-01

    Radioactive waste packages to be disposed of in FRG must meet the waste acceptance requirement of the repository. Compliance with the waste acceptance requirements must be checked by a quality control. Fourteen relevant properties are necessary to be assayed. The quality control group supports the observance of the waste acceptance requirements by the following measures: -checking of the documentation of the waste producers; -random tests at conditioned radioactive wastes; -qualification of conditioning processes; -control of the qualified processes by inspections. The relevant properties of disposal are termed and their checking by non-destructive and if necessary destructive test methods will be explained as well as quality control by process control, i.e. qualification of conditioning processes by instrumentation and documentation. The mobile and stationary testing facilities will be outlined

  6. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  7. National Geodetic Survey (NGS) Geodetic Control Stations, (Horizontal and/or Vertical Control), March 2009

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This data contains a set of geodetic control stations maintained by the National Geodetic Survey. Each geodetic control station in this dataset has either a precise...

  8. [Evaluation of quality of HIV diagnostic procedures in Poland].

    Science.gov (United States)

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  9. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  10. APPLICATION OF HIDDEN MARKOV CHAINS IN QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Hanife DEMIRALP

    2013-01-01

    Full Text Available The ever growing technological innovations and sophistication in industrial processes require adequate checks on quality. Thus, there is an increasing demand for simple and efficient quality control methods. In this regard the control charts stand out in simplicity and efficiency. In this paper, we propose a method of controlling quality based on the theory of hidden Markov chains. Based on samples drawn at different times from the production process, the method obtains the state of the process probabilistically. The main advantage of the method is that it requires no assumption on the normality of the process output.

  11. Microgrid Controller and Advanced Distribution Management System Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Starke, Michael R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Herron, Andrew N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    A microgrid controller, which serves as the heart of a microgrid, is responsible for optimally managing the distributed energy resources, energy storage systems, and responsive demand and for ensuring the microgrid is being operated in an efficient, reliable, and resilient way. As the market for microgrids has blossomed in recently years, many vendors have released their own microgrid controllers to meet the various needs of different microgrid clients. However, due to the absence of a recognized standard for such controllers, vendor-supported microgrid controllers have a range of functionalities that are significantly different from each other in many respects. As a result the current state of the industry has been difficult to assess. To remedy this situation the authors conducted a survey of the functions of microgrid controllers developed by vendors and national laboratories. This report presents a clear indication of the state of the microgrid-controller industry based on analysis of the survey results. The results demonstrate that US Department of Energy funded research in microgrid controllers is unique and not competing with that of industry.

  12. John F. Kennedy Space Center, Safety, Reliability, Maintainability and Quality Assurance, Survey and Audit Program

    Science.gov (United States)

    1994-01-01

    This document is the product of the KSC Survey and Audit Working Group composed of civil service and contractor Safety, Reliability, and Quality Assurance (SR&QA) personnel. The program described herein provides standardized terminology, uniformity of survey and audit operations, and emphasizes process assessments rather than a program based solely on compliance. The program establishes minimum training requirements, adopts an auditor certification methodology, and includes survey and audit metrics for the audited organizations as well as the auditing organization.

  13. Internal quality control practice of thyroid disease related tests and imprecision analysis in China.

    Science.gov (United States)

    Hu, Li-Tao; Wang, Zhi-Guo

    2014-01-01

    Internal quality control (IQC) has a long and well-established role in clinical laboratories and the quality of laboratories has achieved great improvement in China. However, the practice of IQC varies significantly between institutions and many problems still exists. Consequently, the Chinese National Center for Clinical Laboratories has been undertaking monthly nation-wide surveys of current IQC practice of tests since 2010 to monitor laboratory quality. Thyroid disease related tests were chosen for this research. Different numbers of laboratories in China participating national external quality assessment (EQA) schemes of Total Thyroxine (TT4), Total Triiodothyronine (TT3), Free Thyroxine (FT4) and Free Triiodothyronine (FT3) tests, and Thyroid Stimulating Hormone (TSH) measurements, were required to report the IQC information though the national external quality assessment (EQA) network platform. Survey data showed significant variability in all aspects of IQC practice. More than half of the laboratories are using a single concentration level of IQC material and up to 28.6% of the laboratories only use 1(2s) or 1(3s) to monitor IQC results for FT3, TT3, FT4, TT4, and TSH. The medians of the average time intervals of two control tests for FT3, TT3, FT4, TT4, and TSH are 33.6, 35.4, 33.6, 35.4, and 33.6 hours, respectively, more or less 1.4 days. When quality specifications based on biological variation are applied to imprecision evaluation, only 46.3%, 52.1%, 31.3%, 12.8%, and 5.86% laboratories meet the minimum performance for FT3, TT3, FT4, and TT4, 24.5%, 23.6%, 12.8%, and 5.86% of the all meet the desirable performance, and 4.4%, 3.9%, 2.5% and 3.0% of the all meet the optimal performance. While it shows a higher percentage of acceptable laboratories (98.1%, 87.9% and 39.0% meeting the minimum, desirable and optimal performance, respectively) for TSH. Not-well-designed IQC practices may affect the effectiveness of laboratory IQC and, thus, the adequacy of a

  14. Residential Energy Consumption Survey: Quality Profile

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The Residential Energy Consumption Survey (RECS) is a periodic national survey that provides timely information about energy consumption and expenditures of U.S. households and about energy-related characteristics of housing units. The survey was first conducted in 1978 as the National Interim Energy Consumption Survey (NIECS), and the 1979 survey was called the Household Screener Survey. From 1980 through 1982 RECS was conducted annually. The next RECS was fielded in 1984, and since then, the survey has been undertaken at 3-year intervals. The most recent RECS was conducted in 1993.

  15. 22 CFR 96.39 - Information disclosure and quality control practices.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  16. Survey of On-Orbit Sleep Quality: Short-Duration Flyers

    Science.gov (United States)

    Locke, J.; Leveton, L.; Keeton, K.; Whitmire, A.; Patterson, H.; Faulk, J.

    2010-01-01

    The NASA Human Research Program (HRP) Behavioral Health and Performance Element (BHP), in conjunction with the NASA Space Medicine Division, is currently completing the largest systematic, subjective assessment of shuttle astronauts sleep behaviors and sleep quality on Earth, during training periods, and during space flight missions. Since July 2009, a total of 66 astronauts have completed a secure online survey regarding specific sleep strategies, crew policies, and mitigation effectiveness. In addition to the survey, each astronaut participant met individually with trained BHP and SD representatives for a structured, follow-up interview. Data are currently being assessed and the study s principal investigator will be providing some preliminary findings at the Investigators Workshop. Additional analyses will be conducted in the following months to examine predictors of optimal sleep in space, and to evaluate the differences in countermeasure effectiveness between groups based on their sleep experience on the ground and on orbit. A revised survey for a subsequent investigation on the experiences of long-duration flyers will be developed in the Spring and implemented in the Summer of 2010. Findings from both of these investigations will inform countermeasure strategies for astronauts, medical operations, and habitat designers for future exploration missions, as well as upcoming shuttle and ISS missions.

  17. Methodology of Global Adult Tobacco Survey (GATS), Malaysia, 2011.

    Science.gov (United States)

    Omar, Azahadi; Yusoff, Muhammad Fadhli Mohd; Hiong, Tee Guat; Aris, Tahir; Morton, Jeremy; Pujari, Sameer

    Malaysia participated in the second phase of the Global Adult Tobacco Survey (GATS) in 2011. GATS, a new component of the Global Tobacco Surveillance System, is a nationally representative household survey of adults 15 years old or above. The objectives of GATS Malaysia were to (i) systematically monitor tobacco use among adults and track key indicators of tobacco control and (ii) track the implementation of some of the Framework Convention of Tobacco Control (FCTC)-recommended demand related policies. GATS Malaysia 2011 was a nationwide cross-sectional survey using multistage stratified sampling to select 5112 nationally representative households. One individual aged 15 years or older was randomly chosen from each selected household and interviewed using handheld device. GATS Core Questionnaire with optional questions was pre-tested and uploaded into handheld devices after repeated quality control processes. Data collectors were trained through a centralized training. Manuals and picture book were prepared to aid in the training of data collectors and during data collection. Field-level data were aggregated on a daily basis and analysed twice a week. Quality controls were instituted to ensure collection of high quality data. Sample weighting and analysis were conducted with the assistance of researchers from the Centers for Disease Control and Prevention, Atlanta, USA. GATS Malaysia received a total response rate of 85.3% from 5112 adults surveyed. Majority of the respondents were 25-44 years old and Malays. The robust methodology used in the GATS Malaysia provides national estimates for tobacco used classified by socio-demographic characteristics and reliable data on various dimensions of tobacco control.

  18. Water Quality Survey of Splash Pads After A Waterborne Salmonellosis Outbreak--Tennessee, 2014.

    Science.gov (United States)

    Clayton, Joshua L; Manners, Judy; Miller, Susan; Shepherd, Craig; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-06-01

    Waterborne outbreaks of salmonellosis are uncommon. The Tennessee Department of Health investigated a salmonellosis outbreak of 10 cases with the only common risk factor being exposure to a single splash pad. Risks included water splashed in the face at the splash pad and no free residual chlorine in the water system. We surveyed water quality and patron behaviors at splash pads statewide. Of the 29 splash pads participating in the water quality survey, 24 (83%) used a recirculating water system. Of the 24, 5 (21%) water samples were tested by polymerase chain reaction and found to be positive for E. coli, Giardia, norovirus, or Salmonella. Among 95 patrons observed, we identified common high-risk behaviors of sitting on the fountain or spray head and putting mouth to water. Water venue regulations and improved education of patrons are important to aid prevention efforts.

  19. Ocean Data Quality Control

    Science.gov (United States)

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  20. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  1. Quality Controlling CMIP datasets at GFDL

    Science.gov (United States)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  2. Production process and quality control for the HTTR fuel

    International Nuclear Information System (INIS)

    Yoshimuta, S.; Suzuki, N.; Kaneko, M.; Fukuda, K.

    1991-01-01

    Development of the production and inspection technology for High Temperature Engineering Test Reactor (HTTR) fuel has been carried out by cooperative work between Japan Atomic Energy Research Institute (JAERI) and Nuclear Fuel Industries, Ltd (NFI). The performance and the quality level of the developed fuel are well established to meet the design requirements of the HTTR. For the commercial scale production of the fuel, statistical quality control and quality assurance must be carefully considered in order to assure the safety of the HTTR. It is also important to produce the fuel under well controlled process condition. To meet these requirements in the production of the HTTR fuel, a new production process and quality control system is to be introduced in the new facilities. The main feature of the system is a computer integrated control system. Process control data at each production stage of products and semi-products are all gathered by terminal computers and processed by a host computer. The processed information is effectively used for the production, quality and accountancy control. With the aid of this system, all the products will be easily traceable from starting materials to final stages and the statistical evaluation of the quality of products becomes more reliable. (author). 8 figs

  3. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air Quality...

  4. A DELPHI SURVEY ON HOTEL SERVICE QUALITY FRAMEWORKS AND THEIR APPLICATION

    Directory of Open Access Journals (Sweden)

    Joe Kibuye WADAWI

    2010-06-01

    Full Text Available Hotels have become an important aspect of a destination. It is therefore necessary to carry out evaluation of various studies and underpinning concept of quality models used in creating and sustaining leading service culture in hotels. This paper seeks to evaluate some of these expert frameworks using literature survey as the main source of deriving various expert propositions. Findings from the literature survey were further evaluated by Delphi team discussions to help generate recommendations. The study established that managers of hotels need to recognize the scientific significance of service improvement in hotel operations as a requirement for building their own competitive advantage and that of the destination where they operate.

  5. Technology requirement for Halal quality control | Husny | Journal of ...

    African Journals Online (AJOL)

    Technology requirement for Halal quality control. ... Findings show that each industry segments have different technology characteristics preference. ... Keywords: halal industry, quality control; technology assistance; food and beverage; ...

  6. Integrated alarm annunciation and entry control systems -- Survey results

    International Nuclear Information System (INIS)

    Clever, J.J.; Arakaki, L.H.; Monaco, F.M.; Juarros, L.E.; Quintana, G.R.

    1993-10-01

    This report provides the results and analyses of a detailed survey undertaken in Summer 1993 to address integrated intrusion detection alarm annunciation and entry control system issues. This survey was undertaken as a first attempt toward beginning to answer questions about integrated systems and commercial capabilities to meet or partially meet US Department of Energy (DOE) site needs

  7. Internal cost control on the ecological quality of products

    Directory of Open Access Journals (Sweden)

    N.P. Syroid

    2018-04-01

    Full Text Available To improve the environmental quality of products due attention should be paid to control the processes related to environmental quality input of the product. The results of the study help to state the purpose and objectives of the control, also to define objects for internal control of operations cost of environmental quality. So, we believe that the main purpose of internal cost control on the ecological quality of products is the establishment of the correctness and legality of business operations, prevention of violations and abuses in the expenditure of natural, labour, material and financial resources to ensure the minimization of negative impact on the health of consumers and the environment. The basic objectives of internal control of expenditure are brought forward, but it should be noted that they can vary and depend on the size, structure, spheres and types of economic activity of the enterprise, the requirements of management personnel. In the process of identifying the objects of control of environmental quality it should be noted that this list is not exhaustive, but it is most relevant to highlight objects such as genetically modified organisms and waste production. Also the subjects of cost control to environmental quality, their functions and the information base for monitoring are determined. Proper organization of the process of internal cost control on the ecological quality of products would benefit from a clear documentation of transactions, timely and complete registration of accounting data in the registers, the true reflection of information in managerial financial reporting and ensure reduction of the negative impact on the health of consumers and the environment.

  8. Internal quality control: planning and implementation strategies.

    Science.gov (United States)

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  9. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  10. The regulatory maze of quality control

    International Nuclear Information System (INIS)

    Stone, T.I.

    1987-01-01

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  11. Advanced methods of quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Onoufriev, Vladimir

    2004-01-01

    Under pressure of current economic and electricity market situation utilities implement more demanding fuel utilization schemes including higher burn ups and thermal rates, longer fuel cycles and usage of Mo fuel. Therefore, fuel vendors have recently initiated new R and D programmes aimed at improving fuel quality, design and materials to produce robust and reliable fuel. In the beginning of commercial fuel fabrication, emphasis was given to advancements in Quality Control/Quality Assurance related mainly to product itself. During recent years, emphasis was transferred to improvements in process control and to implementation of overall Total Quality Management (TQM) programmes. In the area of fuel quality control, statistical control methods are now widely implemented replacing 100% inspection. This evolution, some practical examples and IAEA activities are described in the paper. The paper presents major findings of the latest IAEA Technical Meetings (TMs) and training courses in the area with emphasis on information received at the TM and training course held in 1999 and other latest publications to provide an overview of new developments in process/quality control, their implementation and results obtained including new approaches to QC

  12. Quality control of PET/CT

    International Nuclear Information System (INIS)

    Angelova, J.; Zajcharov, M.

    2013-01-01

    Full text: Introduction: The aim of this work is to undertake a review of the methods for checking and adjusting the computer and positron emission tomography in the Hospital 'Alexandrovska' by the attached to the equipment phantoms according to the manufacturer prescription in order to fulfill its requirements for the entry of the main parameters image within certain limits. Materials and Methods: At the start of work a check of the lasers setting for patient positioning and 'heat' of the X-ray tube scanner to better image quality were made. Daily verification procedures on the image quality of CT through the water phantom and weekly - 'air' calibration were carried out. In positron part, daily control involves setting the resolution and sensitivity of the scanner through built Ga68 phantom. When commissioning, after repair and at least once a year, it is necessary to verify the accuracy of registration of the pulses from the crystal with a water phantom of known volume and the coincidence between CT and PET image. Results: The process of quality control is interactive. The results are displayed in tables and graphically, with the goal the individual values to fall within the determined by manufacturers range and to meet the standards for image quality. If necessary, the procedure repeats several times until it is fulfilled. Conclusion: Ensuring the quality of the image in positron emission tomography combined with computed tomography, is inextricably linked to accurate and precise diagnosis of tumor processes in the human body

  13. Information-Quality based LV-Grid-Monitoring Framework and its Application to Power-Quality Control

    DEFF Research Database (Denmark)

    Findrik, Mislav; Kristensen, Thomas le Fevre; Hinterhofer, Thomas

    2015-01-01

    The integration of unpredictable renewable energy sources into the low voltage (LV) power grid results in new challenges when it comes to ensuring power quality in the electrical grid. Addressing this problem requires control of not only the secondary substation but also control of flexible assets...... inside the LV grid. In this paper we investigate how the flexibility information of such assets can be accessed by the controller using heterogeneous off-the-shelf communication networks. To achieve this we develop an adaptive monitoring framework, through which the controller can subscribe to the assets......' flexibility information through an API. We define an information quality metric making the monitoring framework able to adapt information access strategies to ensure the information is made available to the controller with the highest possible information quality. To evaluate the monitoring framework...

  14. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Robles, A.; Condor, M.; Caballero, J.; Morote, M.; Garcia, C.; Benites, M.

    1997-01-01

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  15. Compilation, quality control, analysis, and summary of discrete suspended-sediment and ancillary data in the United States, 1901-2010

    Science.gov (United States)

    Lee, Casey J.; Glysson, G. Douglas

    2013-01-01

    Human-induced and natural changes to the transport of sediment and sediment-associated constituents can degrade aquatic ecosystems and limit human uses of streams and rivers. The lack of a dedicated, easily accessible, quality-controlled database of sediment and ancillary data has made it difficult to identify sediment-related water-quality impairments and has limited understanding of how human actions affect suspended-sediment concentrations and transport. The purpose of this report is to describe the creation of a quality-controlled U.S. Geological Survey suspended-sediment database, provide guidance for its use, and summarize characteristics of suspended-sediment data through 2010. The database is provided as an online application at http://cida.usgs.gov/sediment to allow users to view, filter, and retrieve available suspended-sediment and ancillary data. A data recovery, filtration, and quality-control process was performed to expand the availability, representativeness, and utility of existing suspended-sediment data collected by the U.S. Geological Survey in the United States before January 1, 2011. Information on streamflow condition, sediment grain size, and upstream landscape condition were matched to sediment data and sediment-sampling sites to place data in context with factors that may influence sediment transport. Suspended-sediment and selected ancillary data are presented from across the United States with respect to time, streamflow, and landscape condition. Examples of potential uses of this database for identifying sediment-related impairments, assessing trends, and designing new data collection activities are provided. This report and database can support local and national-level decision making, project planning, and data mining activities related to the transport of suspended-sediment and sediment-associated constituents.

  16. Quality control of conventional radiographic facilities in Kinshasa

    International Nuclear Information System (INIS)

    Woto, M.L.; Lukanda, M.V.; Mulumba, L.C.P.; Palangu

    2009-01-01

    The continuous development of medical applications of ionizing radiation, due to the benefit derived by diagnostic or therapeutic patients, their diversity, ease of implementation, explains the importance of medical exposure. The latter is currently the leading cause of human exposure to artificial origin. The purpose of this study is to contribute to the optimization of radiographic facilities in the city of Kinshasa. This study has revealed that city of Kinshasa has an average of 122 medical training with conventional radiology facilities distributed in six districts of health. Of the 122 facilities, only 30 (or 24.59%) are controlled from the point of view of quality assurance. Some generators and X-ray tubes are respectively controlled adjustment and de centered, and other devices are cannibalized. So, nationally and particularly in Kinshasa, quality control equipment and diagnostic facilities is at a generally delayed compared with international recommendations of X W. Major efforts must be made at government level to raise awareness and establish a quality assurance program in diagnostic radiology. An awareness of the entire medical profession and the competent administrative authorities of medical devices could be beneficial to the quality of care delivered to patients, limiting radiation exposure and improving image quality and only the financial balance of the health sector. The delivery of quality care passes through the justification of acts, the development and dissemination of good practice references and the establishment of quality control radiological installations.

  17. Quality control of radiodiagnostics

    International Nuclear Information System (INIS)

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  18. National surveys: a way to manage treatment strategies in Parkinson's disease? Pharmaceutical prescribing patterns and patient experiences of symptom control and their impact on disease

    Directory of Open Access Journals (Sweden)

    Skogar Ö

    2013-07-01

    Full Text Available Örjan Skogar,1,2 Mats Nilsson,1 Carl-Johan Törnhage,3 Johan Lökk2 1Futurum Health Care Academy, Jönköping, 2Institution of Neurobiology, Care Sciences and Society, Karolinska Institutet, Karolinska University Hospital Huddinge, Stockholm, 3Department of Pediatrics, Skaraborg Hospital, Skövde, Sweden Background: The purpose of this study was to draw conclusions from patient-reported experiences in two national surveys from Scandinavia with the intention of comparing treatment strategies and increasing our knowledge of factors that affect the experiences of patients with Parkinson's disease (PD. Methods: A total of 2000 individuals in Sweden and 1300 in Norway were invited to complete postal surveys covering PD-related issues. Patient experiences of diagnostic procedures, symptom control, and follow-up in PD and the effects on symptom-related quality of life were collected. Pharmaceutical prescription data on anti-PD drugs and administrative data were collected from national registries. Results: The surveys were completed by 1553 (78% of the Swedish cohort and 1244 (96% of the Norwegian cohort. Only small differences were seen in disease duration and age distribution. Statistically as well as clinically significant differences in symptom control, diagnostic, and follow-up procedures, as well as in pharmacological treatment and impact on quality of life, were found between the national cohorts independent of disease duration. Conclusion: Information from separate national surveys has the potential to increase our knowledge of patient experiences in PD and can be used to compare, evaluate, educate, and guide health care staff and administrators in optimizing health care for patients with the disease. Keywords: parkinson's disease, diagnosis, follow-up, pharmaceutical prescription, quality of life, survey

  19. Management Model for efficient quality control in new buildings

    Directory of Open Access Journals (Sweden)

    C. E. Rodríguez-Jiménez

    2017-09-01

    Full Text Available The management of the quality control of each building process is usually set up in Spain from different levels of demand. This work tries to obtain a model of reference, to compare the quality control of the building process of a specific product (building, and to be able to evaluate its warranty level. In the quest of this purpose, we take credit of specialized sources and 153 real cases of Quality Control were carefully revised using a multi-judgment method. Applying different techniques to get a specific valuation (impartial of the input parameters through Delphi’s method (17 experts query, whose matrix treatment with the Fuzzy-QFD tool condenses numerical references through a weighted distribution of the selected functions and their corresponding conditioning factors. The model thus obtained (M153 is useful in order to have a quality control reference to meet the expectations of the quality.

  20. Review of the first 50 cases completed by the RACR mammography QA programme; Phantom image quality, processor control and dose considerations

    International Nuclear Information System (INIS)

    McLean, D.; Chan, W.; Eckert, M.; Heard, R.

    1997-01-01

    The Mammography Quality Assurance Programme, recently established by the Royal Australasian College of Radiologists, has processed the first 50 applications. This programme, which closely follows the programme of the American College of Radiology (ACR), utilizes phantom film images, thermoluminescent dosimetry measurement of mean glandular dose, processor control charts, clinical images, equipment reports and required survey information to establish that a centre conforms to a minimum standard in mammography. The present paper describes the initial results of the first phantom images, dose measurements, processor control and survey information. Fifty films have been evaluated up to the present time with a failure rate of 26%. The major causes of failure were unacceptable film artefacts and poor contrast (as indicated by reduced fibre and mass visibility). A surprising result was the high failure in processing, where 23% of units reviewed had significant problems, including failure to keep the processor within required control limits. Only one centre recorded a mean glandular dose above 2 mGy with no centre over the 3 mGy limit. A review of the frequency of the quality control testing shows that the acceptance of quality assurance in mammography, while greater than in the initial stages of the ACR programme, is less than current US practice. These initial results for the accreditation process probably reflect an initial period of adjustment, as seen by the high pass rate achieved by centres that have re submitted material to gain accreditation. (authors)

  1. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  2. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  3. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    Science.gov (United States)

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  4. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  5. Quality control in haemostasis.

    Science.gov (United States)

    Capel, P; Chatelain, B; Leclerq, R; Lust, A; Masure, R; Arnout, J

    1992-01-01

    Laboratory investigation of the haemostatic system deserves particular procedures in the quality control of analytical variables as well as preanalytical variables. This paper reviews the precautions that have to be taken in the blood prelevement, the transport of the tubes and the performance of the laboratory tests aimed to investigate the haemostatic system in order to obtain reliable results.

  6. USE OF INTELLECTUAL TECHNOLOGIES FOR QUALITY CONTROL OF CURD

    Directory of Open Access Journals (Sweden)

    M. M. Blagoveshchenskaya

    2015-01-01

    Full Text Available In this article, we consider additional method of quality control of curds by organoleptic properties. Method consists in construction of neural network model to estimate quality of curds by input and output parameters. Quality control of curds by organoleptic properties is not necessary according to state standard specification, therefore we use exemplary 5-score scale for organoleptic estimation. Author gives an example of fundamental operation which is necessary for neural networks projection and gives recommendation for integrated hardware/software solution design. This method makes easier quality control of final product because operator can react on digression in the technological process in proper time (use data recommended by neural network, predict quality of final product in case when technological parameters deviate from the norm.

  7. Using lot quality-assurance sampling and area sampling to identify priority areas for trachoma control: Viet Nam.

    Science.gov (United States)

    Myatt, Mark; Mai, Nguyen Phuong; Quynh, Nguyen Quang; Nga, Nguyen Huy; Tai, Ha Huy; Long, Nguyen Hung; Minh, Tran Hung; Limburg, Hans

    2005-10-01

    To report on the use of lot quality-assurance sampling (LQAS) surveys undertaken within an area-sampling framework to identify priority areas for intervention with trachoma control activities in Viet Nam. The LQAS survey method for the rapid assessment of the prevalence of active trachoma was adapted for use in Viet Nam with the aim of classifying individual communes by the prevalence of active trachoma among children in primary school. School-based sampling was used; school sites to be sampled were selected using an area-sampling approach. A total of 719 communes in 41 districts in 18 provinces were surveyed. Survey staff found the LQAS survey method both simple and rapid to use after initial problems with area-sampling methods were identified and remedied. The method yielded a finer spatial resolution of prevalence than had been previously achieved in Viet Nam using semiquantitative rapid assessment surveys and multistage cluster-sampled surveys. When used with area-sampling techniques, the LQAS survey method has the potential to form the basis of survey instruments that can be used to efficiently target resources for interventions against active trachoma. With additional work, such methods could provide a generally applicable tool for effective programme planning and for the certification of the elimination of trachoma as a blinding disease.

  8. Quality-assurance and data management plan for groundwater activities by the U.S. Geological Survey in Kansas, 2014

    Science.gov (United States)

    Putnam, James E.; Hansen, Cristi V.

    2014-01-01

    As the Nation’s principle earth-science information agency, the U.S. Geological Survey (USGS) is depended on to collect data of the highest quality. This document is a quality-assurance plan for groundwater activities (GWQAP) of the Kansas Water Science Center. The purpose of this GWQAP is to establish a minimum set of guidelines and practices to be used by the Kansas Water Science Center to ensure quality in groundwater activities. Included within these practices are the assignment of responsibilities for implementing quality-assurance activities in the Kansas Water Science Center and establishment of review procedures needed to ensure the technical quality and reliability of the groundwater products. In addition, this GWQAP is intended to complement quality-assurance plans for surface-water and water-quality activities and similar plans for the Kansas Water Science Center and general project activities throughout the USGS. This document provides the framework for collecting, analyzing, and reporting groundwater data that are quality assured and quality controlled. This GWQAP presents policies directing the collection, processing, analysis, storage, review, and publication of groundwater data. In addition, policies related to organizational responsibilities, training, project planning, and safety are presented. These policies and practices pertain to all groundwater activities conducted by the Kansas Water Science Center, including data-collection programs, interpretive and research projects. This report also includes the data management plan that describes the progression of data management from data collection to archiving and publication.

  9. National Beef Quality Audit-2011: In-plant survey of targeted carcass characteristics related to quality, quantity, value, and marketing of fed steers and heifers

    Science.gov (United States)

    The National Beef Quality Audit – 2011 (NBQA-2011) assessed the current status of quality and consistency of fed steers and heifers. Beef carcasses (n = 9,802), representing approximately 10 percent of each production lot in 28 beef processing facilities, were selected randomly for the survey. Car...

  10. EQUIP: A European Survey of Quality Criteria for the Evaluation of Databases.

    Science.gov (United States)

    Wilson, T. D.

    1998-01-01

    Reports on two stages of an investigation into the perceived quality of online databases. Presents data from 989 questionnaires from 600 database users in 12 European and Scandinavian countries and results of a test of the SERVQUAL methodology for identifying user expectations about database services. Lists statements used in the SERVQUAL survey.…

  11. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  12. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  13. 40 CFR 81.17 - Metropolitan Los Angeles Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.17 Metropolitan Los Angeles Air Quality Control Region. The Metropolitan Los Angeles Air Quality Control Region consists of the following territorial area (including the territorial... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Metropolitan Los Angeles Air Quality...

  14. 40 CFR 81.32 - Puget Sound Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.32 Puget Sound Intrastate Air Quality Control Region. The Puget Sound Intrastate Air Quality Control Region (Washington) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puget Sound Intrastate Air Quality...

  15. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  16. Use of a customer satisfaction survey by health care regulators: a tool for total quality management.

    Science.gov (United States)

    Andrzejewski, N; Lagua, R T

    1997-01-01

    To conduct a survey of health care providers to determine the quality of service provided by the staff of a regulatory agency; to collect information on provider needs and expectations; to identify perceived and potential problems that need improvement; and to make changes to improve regulatory services. The authors surveyed health care providers using a customer satisfaction questionnaire developed in collaboration with a group of providers and a research consultant. The questionnaire contained 20 declarative statements that fell into six quality domains: proficiency, judgment, responsiveness, communication, accommodation, and relevance. A 10% level of dissatisfaction was used as the acceptable performance standard. The survey was mailed to 324 hospitals, nursing homes, home care agencies, hospices, ambulatory care centers, and health maintenance organizations. Fifty-six percent of provider agencies responded; more than half had written comments. The three highest levels of customer satisfaction were in courtesy of regulatory staff (90%), efficient use of onsite time (84%), and respect for provider employees (83%). The three lowest levels of satisfaction were in the judgment domain; only 44% felt that there was consistency among regulatory staff in the interpretation of regulations, only 45% felt that interpretations of regulations were flexible and reasonable, and only 49% felt that regulations were applied objectively. Nine of 20 quality indicators had dissatisfaction ratings of more than 10%; these were considered priorities for improvement. Responses to the survey identified a number of specific areas of concern; these findings are being incorporated into the continuous quality improvement program of the office.

  17. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  18. Quality control in paediatric nuclear medicine

    International Nuclear Information System (INIS)

    Fischer, S.; Hahn, K.

    1997-01-01

    Nuclear medicine examinations in children require a maximum in quality. This is true for the preparation of the child and parents, the imaging procedure, processing and documentation. It is necessary that quality control through all steps is performed regularly. The aim must be that the children receive a minimum radiation dose, while there needs to be a high quality in imaging and clinical information from the study. Furthermore the child should not be too much psychologically affected by the nuclear medicine examination. (orig.) [de

  19. Development of remote controller for an EMI test receiver in site survey

    International Nuclear Information System (INIS)

    Cha, K. H.; Hwang, I. G.; Lee, D. Y.; Lee, K. Y.; Park, J. K.

    2000-01-01

    EMI assessment, which is based on the Site survey(the measurement of EMI noise) in an operating plant, can be considered for system design. Our Site survey is being planned to utilize the ESI7 model, to be manufactured as the EMI test receiver by Rodge-Schwaltz GmbH. But the ESI7 is often manipulated by manual if a Site survey is continued for some days in nuclear power plant. The problem can be resolved if a remote controller is implemented for the ESI7 and it controls the ESI7. The Remote Controller has its functions for supporting the ESI7 manual tasks, including storing mass SCAN data onto external PC memory (hard-disk), controlling ESI7, and analyzing the stored SCAN data. These functions have been implemented in 'G' programming of LabVIEW software under a notebook PC with PCMCIA-GPIB card. The Remote Controller prototype will be applied to store the real EMI measurements in the coming Site survey and analyze the data after integrated tests and their evaluation

  20. Quality assurance and quality control in fabrication of heat exchanger tubes

    International Nuclear Information System (INIS)

    Duennewald, A.

    1980-01-01

    Object of this report is the manufacture of heat exchanger tubes. A comprehensive manufacturing and test program has to be established to assure and prove and equal tube quality. This requires a functionally operating quality assurance system combined with a production exactly planned in advance. A specific continuous production line for heat exchanger tubes has been erected at the Hellenthal plant of the Mannesmannroehren-Werke. All production steps and heat treatments are generally controlled by a quality control department. Non-destructive testing of each tube produced in standard length is performed on several agregates in line using ultrasonic and/or eddy current technique. All tests are generally performed in the presence of quality inspectors or surveyors. For a lot of heat exchangers the straight tubes have to be hairpin bended. To avoid the risk of stress corrosion cracking, it is recommended to procreate defined compression stresses in the outside tube surface. Prior to releasing the tubes to shipment, the completeness of the documentation as to the manufacturing steps and inspection agreed upon is thoroughly checked. (RW)

  1. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  2. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  3. 40 CFR 81.110 - Camden-Sumter Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.110 Camden-Sumter Intrastate Air Quality Control Region. The Camden-Sumter Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Camden-Sumter Intrastate Air Quality...

  4. 40 CFR 81.52 - Wasatch Front Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.52 Wasatch Front Intrastate Air Quality Control Region. The Wasatch Front Intrastate Air Quality Control Region (Utah) consists of the territorial area encompassed by the boundaries... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Wasatch Front Intrastate Air Quality...

  5. 40 CFR 81.54 - Cook Inlet Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.54 Cook Inlet Intrastate Air Quality Control Region. The Cook Inlet Intrastate Air Quality Control Region (Alaska) consists of the territorial area encompassed by the boundaries... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Cook Inlet Intrastate Air Quality...

  6. 40 CFR 81.95 - Central Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.95 Central Florida Intrastate Air Quality Control Region. The Central Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by the boundaries of the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Central Florida Intrastate Air Quality...

  7. Y-STR frequency surveying method

    DEFF Research Database (Denmark)

    Willuweit, Sascha; Caliebe, Amke; Andersen, Mikkel Meyer

    2011-01-01

    Reasonable formalized methods to estimate the frequencies of DNA profiles generated from lineage markers have been proposed in the past years and were discussed in the forensic community. Recently, collections of population data on the frequencies of variations in Y chromosomal STR profiles have...... reached a new quality with the establishment of the comprehensive neatly quality-controlled reference database YHRD. Grounded on such unrivalled empirical material from hundreds of populations studies the core assumption of the Haplotype Frequency Surveying Method originally described 10 years ago can...... be tested and improved. Here we provide new approaches to calculate the parameters used in the frequency surveying method: a maximum likelihood estimation of the regression parameters (r1, r2, s1 and s2) and a revised Frequency Surveying framework with variable binning and a database preprocessing to take...

  8. Quality control and quality assurance philosophy introduced in national personnel dosimetry service

    International Nuclear Information System (INIS)

    Trousil, J.; Zelenka, Z.; Kvasnicka, O.

    2008-01-01

    There in National Personnel Dosimetry Service (NPDS) the implementation of the control system to guarantee the credibility of the measured personal dose equivalents results was given on the basis of the international recommendations published by the European Commission and the IAEA and in particular of the decree of the SUJB No. 132/2008 Coll. The quality control and the quality assurance are carried out in all three personal dosimetry services introduced in NPDS: in the film badge, thermoluminescent (TL) and neutron dosimetry. (authors)

  9. Survey of Radiation Oncology Centres in Australia: report of the radiation oncology treatment quality program

    International Nuclear Information System (INIS)

    Klybaba, M.; Kenny, L.; Kron, T.; Harris, J.; O'Brien, P.

    2009-01-01

    Full text: One of the first steps towards the development of a comprehensive quality program for radiation oncology in Australia has been a survey of practice. This paper reports on the results of the survey that should inform the development of standards for radiation oncology in Australia. A questionnaire of 108 questions spanning aspects of treatment services, equipment, staff, infrastructure and available quality systems was mailed to all facilities providing radiation treatment services in Australia (n = 45). Information of 42 sites was received by June 2006 providing data on 113 operational linear accelerators of which approximately 2/3 are equipped with multi-leaf collimators. More than 75% of facilities were participating in a formal quality assurance (QA) system, with 63% following a nationally or internationally recognised system. However, there was considerable variation in the availability of policies and procedures specific to quality aspects, and the review of these. Policies for monitoring patient waiting times for treatment were documented at just 71% of all facilities. Although 85% of all centres do, in fact, monitor machine throughput, the number and types of efficiency measures varied markedly, thereby limiting the comparative use of these results. Centres identified workload as the single most common factor responsible for limiting staff involvement in both QA processes and clinical trial participation. The data collected in this 'snapshot' survey provide a unique and comprehensive baseline for future comparisons and evaluation of changes

  10. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  11. 40 CFR 81.80 - Las Vegas Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.80 Las Vegas Intrastate Air Quality Control Region. The Las Vegas Intrastate Air Quality Control Region (Nevada) has been revised to consist of the territorial area encompassed by... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Las Vegas Intrastate Air Quality...

  12. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  13. Comparing data quality and cost from three modes of on-board transit passenger surveys.

    Science.gov (United States)

    2015-06-01

    This report presents the findings from a research project investigating the relative data quality and administration costs for three : different modes of surveying bus passengers that produce results generalizable to the full passenger population. Th...

  14. Guidelines for quality assurance and quality control of fish taxonomic data collected as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Walsh, Stephen Joseph; Meador, Michael R.

    1998-01-01

    Fish community structure is characterized by the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of a perennial, multidisciplinary approach to evaluating the physical, chemical, and biological conditions of the Nation's water resources. The objective of quality assurance and quality control of fish taxonomic data that are collected as part of the NAWQA Program is to establish uniform guidelines and protocols for the identification, processing, and archiving of fish specimens to ensure that accurate and reliable data are collected. Study unit biologists, collaborating with regional biologists and fish taxonomic specialists, prepare a pre-sampling study plan that includes a preliminary faunal list and identification of an ichthyological curation center for receiving preserved fish specimens. Problematic taxonomic issues and protected taxa also are identified in the study plan, and collecting permits are obtained in advance of sampling activities. Taxonomic specialists are selected to identify fish specimens in the field and to assist in determining what fish specimens should be sacrificed, fixed, and preserved for laboratory identification, independent taxonomic verification, and long-term storage in reference or voucher collections. Quantitative and qualitative sampling of fishes follows standard methods previously established for the NAWQA Program. Common ichthyological techniques are used to process samples in the field and prepare fish specimens to be returned to the laboratory or sent to an institutional repository. Taxonomic identifications are reported by using a standardized list of scientific names that provides nomenclatural consistency and uniformity across study units.

  15. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  16. Introduction to Quality Control in a Compounding Pharmacy.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    A quality-based program is vital in every compounding pharmacy to ensure that each preparation is compounded properly and is stable for its expected duration of use. This article discusses quality control, quality assurance, continuous quality improvement, and also describes the components of an in-house (in-pharmacy) quality program, as well as the role of outside laboratories. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  17. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  18. Internal quality control indicators of cervical cytopathology exams performed in laboratories monitored by the External Quality Control Laboratory.

    Science.gov (United States)

    Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti

    2014-09-01

    To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.

  19. Development of the gaharu oil quality control

    International Nuclear Information System (INIS)

    Chong Saw Peng; Mohd Fajri Osman; Shyful Azizi Abdul Rahman; Khairuddin Abdul Rahim; Mat Rasol Awang

    2010-01-01

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  20. National surveys on internal quality control for blood gas analysis and related electrolytes in clinical laboratories of China.

    Science.gov (United States)

    Duan, Min; Wang, Wei; Zhao, Haijian; Zhang, Chuanbao; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2018-05-01

    Internal quality control (IQC) is essential for precision evaluation and continuous quality improvement. This study aims to investigate the IQC status of blood gas analysis (BGA) in clinical laboratories of China from 2014 to 2017. IQC information on BGA (including pH, pCO2, pO2, Na+, K+, Ca2+, Cl-) was submitted by external quality assessment (EQA) participant laboratories and collected through Clinet-EQA reporting system in March from 2014 to 2017. First, current CVs were compared among different years and measurement systems. Then, percentages of laboratories meeting five allowable imprecision specifications for each analyte were calculated, respectively. Finally, laboratories were divided into different groups based on control rules and frequency to compare their variation trend. The current CVs of BGA were significantly decreasing from 2014 to 2017. pH and pCO2 got the highest pass rates when compared with the minimum imprecision specification, whereas pO2, Na+, K+, Ca2+, Cl- got the highest pass rates when 1/3 TEa imprecision specification applied. The pass rates of pH, pO2, Na+, K+, Ca2+, Cl- were significantly increasing during the 4 years. The comparisons of current CVs among different measurement systems showed that the precision performance of different analytes among different measurement systems had no regular distribution from 2014 to 2017. The analysis of IQC practice indicated great progress and improvement among different years. The imprecision performance of BGA has improved from 2014 to 2017, but the status of imprecision performance in China remains unsatisfying. Therefore, further investigation and continuous improvement measures should be taken.

  1. Survey of Indoor Air Quality in the University of Alaska

    DEFF Research Database (Denmark)

    Kotol, Martin; Craven, Colin; Rode, Carsten

    2014-01-01

    problem which is poor indoor air quality (IAQ). During summer 2012 four student homes were built in Fairbanks, Alaska as a part of Sustainable Village project. The aim of this project is to promote sustainable ways of living in the Arctic and to study new technologies and their applicability in the cold......In cold climates living inside the heated space requires considerable amounts of heat. With the intention to decrease the heating demand, people are insulating their homes and make them more air tight. With the natural infiltration being brought close to zero there has been an increase of a new...... north. This paper presents the results of an IAQ survey performed in the homes during two weeks in December 2012. During this survey the air temperature, relative humidity (RH) and CO2 concentration were measured in all occupied bedrooms along with monitoring of the ventilation units. The results have...

  2. What are patient factors associated with the quality of diabetes care?: results from the Korean National Health and Nutrition Examination Survey

    Directory of Open Access Journals (Sweden)

    Ko Ki

    2012-08-01

    Full Text Available Abstract Background Recently there has been a growing interest in healthcare quality control in Korea. We examined the association between patient factors and quality indicators of diabetic care among Korean adults with diabetes. Methods We obtained a sample of 335 adults aged 20 or older diagnosed with diabetes from the 2005 Korean National Health and Nutrition Examination Survey. Patient factors were divided into two categories: socioeconomic position and health-related factors. Quality indicators for diabetes care were defined as receiving preventive care services for diabetes complications (e.g., fundus examination, microalbuminuria examination, diabetes education and diabetes-related clinical outcomes (e.g., HbA1c, blood pressure, LDL-cholesterol. We performed multiple logistic regression analyses for each quality indicator. Results We found that people with lower education levels or shorter duration of diabetes illness were less likely to receive preventive care services for diabetes complications. Women or people with longer duration of diabetes were less likely to reach the glycemic target. Obese diabetic patients were less likely to accomplish adequate control of blood pressure and LDL-cholesterol. Conclusions Several factors of patients with diabetes, such as education level, duration of illness, gender, and obesity grade are associated with the quality of diabetes care. These findings can help inform policy makers about subpopulations at risk in developing a public health strategy in the future.

  3. Quality control for exposure assessment in epidemiological studies

    DEFF Research Database (Denmark)

    Bornkessel, C; Blettner, M; Breckenkamp, J

    2010-01-01

    In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy...... was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/-1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded...... from the analysis. As a result of continuous quality control procedures, the confidence in the measurements obtained during the field work was strengthened significantly....

  4. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  5. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    1996-12-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  6. A quality control program for radiation sources

    International Nuclear Information System (INIS)

    Almeida, C.E. de; Sibata, C.H.; Cecatti, E.R.; Kawakami, N.S.; Alexandre, A.C.; Chiavegatti Junior, M.

    1982-01-01

    An extensive quality control program was established covering the following areas: physical parameters of the therapeutical machines, dosimetric standards, preventive maintenance of radiation sources and measuring instruments. A critical evaluation of this program was done after two years (1977-1979) of routine application and the results will be presented. The fluctuation on physical parameters strongly supports the efforts and cost of a quality control program. This program has certainly improved the accuracy required on the delivery of the prescribed dose for radiotherapy treatment. (Author) [pt

  7. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    1991-05-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  8. Physical aspects of quality assurance in radiotherapy: A protocol for quality control

    International Nuclear Information System (INIS)

    Aguirre, J.F.; Alfonso-Laguardia, R.; Andreo, P.; Brunetto, M.; Marenco-Zuniga, H.; Gutt, F.; Torres-Calderon, A.

    2000-06-01

    In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a medical physicist in a radiotherapy treatment unit and related equipment, and how this should be made. The latter is made through several appendices, which make the document rather unique. The protocol was developed by medical physicists of the region for the professionals of the region, and it is the first document of this kind ever written in Spanish. A training course was organized in November 1998 (Havana, Cuba) where its practical implementation was taught. There are plans to have this document translated into different languages for the various regions having similar TC projects. (author)

  9. Course Evaluation Systems for Open-ended Quality Enhancement

    DEFF Research Database (Denmark)

    Piihl, Jesper; Rasmussen, Jens Smed

    2013-01-01

    Quality in higher education is widely controlled through surveys asking students to evaluate teaching. However, control of quality does not necessarily lead to enhancement of quality. Drawing on accounting research and a case study, a measurement-based and open-ended quality control system...... emphasising quality enhancement is suggested. The case shows how interactive use of performance measurement can lead to more engaged and enabling dialogue amongst involved actors concerning quality enhancement, however institutionalised beliefs regarding course evaluation systems makes a change challenging....... The chapter suggests that open-ended measurement systems enabling stakeholders to take responsibility for quality enhancement is not so much a matter of technical design as a matter of an enabling style of use....

  10. Quality control of Ling'ao nuclear power station civil construction

    International Nuclear Information System (INIS)

    Lu Buliang; Ye Changyuan

    2001-01-01

    Based on the quality control model adopted during Ling'ao Nuclear Power Station construction, the author briefly introduces quality control process of some main civil construction activities (reinforced concrete, steel liner, steel works and prestressing force) of nuclear power station, and makes some descriptions on non-conformance control of civil works. These quality control processes described come from the concrete practice during civil construction of Ling'ao Nuclear Power Station, and are based on Daya Bay Nuclear Power Station construction experience

  11. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  12. Housing tenancy,data management and quality control

    NARCIS (Netherlands)

    Smeets, J.J.A.M.; Timmermans, H.J.P.

    1993-01-01

    This paper deal s with housing tenancy, data management and quality control. The proposed method is focused on quality characteristics of housing estates in view of rentability risks. It entails a cycle of registration, analysis and implementation of measures. The starting point is the behaviour of

  13. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Survey and comparison of sleep quality among fixed and changing shift staff in a steel factory in Tehran, Iran.

    Science.gov (United States)

    Mohammadian, Farugh; Abbasinia, Marzieh; Rahmani, Abdolrasoul; Monazzam, Mohammad Reza; Asghari, Mehdi; Ahmadnezhad, Iman; Asadi, Ali

    2013-01-01

    Given the hazardous nature of the work in steel factories and that the staff has to deal with hazardous equipment and machines, improper sleep quality and drowsiness among the works tackles performance and boosts rate of job accidents. This study is aimed to survey the quality of sleep and sleepiness status and the pertinent factors among the workers in a rolling mill and a steel production company in Tehran, Iran. In a Cross-Sectional study 2011, 180 workers were selected randomly from a rolling mill and a steel production company in Tehran. A questionnaire was designed to collect demographic data and variables of work condition. Pitersborg's sleep quality questionnaire was used to survey quality and problems of Participants' sleep. Epworth Sleepiness questionnaire was used to deals with sleepiness during work, studying, watching TV, or during time spent in public. Average score of sleep quality for the fixed shift staff and changing shift staff were 7.5±2.82 and 8.49±2.95 respectively. Surveys of sleep quality for the two groups of the participants based on T-test showed a significant difference between the two groups so that the changing shift staff group suffered poorer sleep quality (p=0.03). Comparison of average drowsiness scores between the two groups of participants based on Mann-Whitney test showed no significant difference (p>0.005). Chi square test showed a significant difference between severity of drowsiness and type of working shift (p =0.028 and 0.009). Staff in revolving shifts suffers poor sleep quality comparing with staff with fixed working shift. Moreover, type of working shift greatly affects severity of drowsiness as staff at different work shift experienced different level of sleepiness. It is essential to survey sleep disorder of the staff in the industry and pay more emphasis on sleep disorder epidemic in other fields of industry.

  15. Title IV Quality Control Project, Stage II. Management Option II: Delivery System Quality Improvements.

    Science.gov (United States)

    Advanced Technology, Inc., Reston, VA.

    Stage Two of the Title IV Quality Control Project is an integrated study of quality in five related Federal financial aid programs for postsecondary students. Section 1 of the paper establishes a framework for defining quality improvements, in order to identify the types of changes that would tend to improve quality across all facets of the…

  16. 40 CFR 62.7856 - Albuquerque/Bernalillo County Air Quality Control Board.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Board. 62.7856 Section 62.7856 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Albuquerque/Bernalillo County Air Quality Control Board. (a) Identification of Plan. Albuquerque-Bernalillo... County Air Quality Control Board on November 9, 2005. (b) Identification of Sources. The plan applies to...

  17. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Mississippi Intrastate Air... Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  18. 40 CFR 81.216 - Northeast Indiana Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Indiana Intrastate Air... Air Quality Control Regions § 81.216 Northeast Indiana Intrastate Air Quality Control Region. The Northeast Indiana Intrastate Air Quality Control Region (Indiana) consists of the territorial area...

  19. 40 CFR 81.162 - Northeast Plateau Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Plateau Intrastate Air... Air Quality Control Regions § 81.162 Northeast Plateau Intrastate Air Quality Control Region. The Northeast Plateau Intrastate Air Quality Control Region (California) consists of the territorial area...

  20. The process of managerial control in quality improvement initiatives.

    Science.gov (United States)

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.

  1. Uranium resource evaluation project quality assurance evaluation

    International Nuclear Information System (INIS)

    Grimes, J.G.

    1981-01-01

    This evaluation was conducted over an eight-month period from February 4 through October 1, 1980. During this time, field sampling was suspended for an indefinite time period while the National Uranium Resource Evaluation (NURE) Program underwent restructuring. In addition, the Uranium Resource Evaluation (URE) Project archives are being restructured. Since it is difficult to evaluate quality assurance needs of a program that is undergoing drastic change and because sections of the evaluation were well along before these changes were announced, this evaluation reflects the situation as it was during February 1980. The following quality assurance related programs are continuing to date: (1) periodic checks of field sampling procedures by the Supervising Field Geologist and the Director of Field Operations; (2) verification of field form information and laboratory analytical data verification for all geochemical surveys; (3) URE Project laboratory quality control program (all elements routinely analyzed); and (4) Ames interlaboratory quality control program (uranium only). UCC-ND was given the responsibility of conducting a Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) survey in the Central United States (Illinois, Indiana, Iowa, Kansas, Michigan, Minnesota, Nebraska, North Dakota, Oklahoma, Texas, South Dakota, and Wisconsin). During 1979 and 1980, 13 detailed surveys were conducted by the URE Project in the Central and Western United States to characterize the hydrogeochemistry, stream sediment geochemistry, and/or radiometric patterns of known or potential uranium occurrences. Beginning in 1980, the HSSR surveys were modified to the Regional Hydrogeochemical and Stream Sediment (RHSS) surveys

  2. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  3. Customer satisfaction survey to improve the European cystic fibrosis external quality assessment scheme.

    Science.gov (United States)

    Berwouts, Sarah; Dequeker, Elisabeth

    2011-08-01

    The Cystic Fibrosis European Network, coordinated from within the Katholieke Universiteit Leuven, is the provider of the European cystic fibrosis external quality assessment (EQA) scheme. The network aimed to seek feedback from laboratories that participated in the cystic fibrosis scheme in order to improve services offered. In this study we analysed responses to an on-line customer satisfaction survey conducted between September and November 2009. The survey was sent to 213 laboratories that participated in the cystic fibrosis EQA scheme of 2008; 69 laboratories (32%) responded. Scores for importance and satisfaction were obtained from a five-point Likert scale for 24 attributes. A score of one corresponded to very dissatisfied/very unimportant and five corresponded to very satisfied/very important. Means were calculated and placed in a two-dimensional grid (importance-satisfaction analysis). Means were subtracted from each other to obtain gap values (gap-analysis). No attribute had a mean score below 3.63. The overall mean of satisfaction was 4.35. Opportunities for improvement enclosed clarity, usefulness and completeness of the general report and individual comments, and user-friendliness of the electronic datasheet. This type of customer satisfaction survey was a valuable instrument to identify opportunities to improve the cystic fibrosis EQA scheme. It should be conducted on a regular basis to reveal new opportunities in the future and to assess effectiveness of actions taken. Moreover, it could be a model for other EQA providers seeking feedback from participants. Overall, the customer satisfaction survey provided a powerful quality of care improvement tool.

  4. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  5. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is

  6. Safety of timber : An analysis of quality control options

    NARCIS (Netherlands)

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance

  7. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  8. 40 CFR 81.256 - Northeast Iowa Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Iowa Intrastate Air Quality Control Region. 81.256 Section 81.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.256 Northeast Iowa Intrastate Air Quality Control Region. The Northeast Iowa...

  9. 40 CFR 81.237 - Northeast Georgia Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Georgia Intrastate Air... Air Quality Control Regions § 81.237 Northeast Georgia Intrastate Air Quality Control Region. The Northeast Georgia Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  10. 40 CFR 81.139 - Northeast Arkansas Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Arkansas Intrastate Air... Air Quality Control Regions § 81.139 Northeast Arkansas Intrastate Air Quality Control Region. The Northeast Arkansas Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  11. 40 CFR 81.251 - Northeast Kansas Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Kansas Intrastate Air... Air Quality Control Regions § 81.251 Northeast Kansas Intrastate Air Quality Control Region. The Northeast Kansas Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  12. 40 CFR 81.134 - Austin-Waco Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Austin-Waco Intrastate Air Quality Control Region. 81.134 Section 81.134 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.134 Austin-Waco Intrastate Air Quality Control Region. The Austin-Waco...

  13. 40 CFR 81.121 - Four Corners Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Four Corners Interstate Air Quality Control Region. 81.121 Section 81.121 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.121 Four Corners Interstate Air Quality Control Region. The Four Corners...

  14. 40 CFR 81.93 - Hampton Roads Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Hampton Roads Intrastate Air Quality Control Region. 81.93 Section 81.93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.93 Hampton Roads Intrastate Air Quality Control Region. The Metropolitan...

  15. The Astro-WISE approach to quality control for astronomical data

    NARCIS (Netherlands)

    Mc Farland, John; Helmich, Ewout M.; Valentijn, Edwin A.

    We present a novel approach to quality control during the processing of astronomical data. Quality control in the Astro-WISE Information System is integral to all aspects of data handing and provides transparent access to quality estimators for all stages of data reduction from the raw image to the

  16. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  17. External Quality Control for Dried Blood Spot Based C-reactive Protein Assay: Experience from the Indonesia Family Life Survey and the Longitudinal Aging Study in India

    Science.gov (United States)

    Hu, Peifeng; Herningtyas, Elizabeth H.; Kale, Varsha; Crimmins, Eileen M.; Risbud, Arun R.; McCreath, Heather; Lee, Jinkook; Strauss, John; O’Brien, Jennifer C.; Bloom, David E.; Seeman, Teresa E.

    2015-01-01

    Measurement of C-reactive protein, a marker of inflammation, in dried blood spots has been increasingly incorporated in community-based social surveys internationally. Although the dried blood spot based CRP assay protocol has been validated in the United States, it remains unclear whether laboratories in other less developed countries can generate C-reactive protein results of similar quality. We therefore conducted external quality monitoring for dried blood spot based C-reactive protein measurement for the Indonesia Family Life Survey and the Longitudinal Aging Study in India. Our results show that dried blood spot based C-reactive protein results in these two countries have excellent and consistent correlations with serum-based values and dried blood spot based results from the reference laboratory in the United States. Even though the results from duplicate samples may have fluctuations in absolute values over time, the relative order of C-reactive protein levels remains similar and the estimates are reasonably precise for population-based studies that investigate the association between socioeconomic factors and health. PMID:25879265

  18. Process-based quality for thermal spray via feedback control

    Science.gov (United States)

    Dykhuizen, R. C.; Neiser, R. A.

    2006-09-01

    Quality control of a thermal spray system manufacturing process is difficult due to the many input variables that need to be controlled. Great care must be taken to ensure that the process remains constant to obtain a consistent quality of the parts. Control is greatly complicated by the fact that measurement of particle velocities and temperatures is a noisy stochastic process. This article illustrates the application of quality control concepts to a wire flame spray process. A central feature of the real-time control system is an automatic feedback control scheme that provides fine adjustments to ensure that uncontrolled variations are accommodated. It is shown how the control vectors can be constructed from simple process maps to independently control particle velocity and temperature. This control scheme is shown to perform well in a real production environment. We also demonstrate that slight variations in the feed wire curvature can greatly influence the process. Finally, the geometry of the spray system and sensor must remain constant for the best reproducibility.

  19. CT dosimetry and quality control of its operation

    International Nuclear Information System (INIS)

    Mechi, Saida

    2011-01-01

    This thesis focuses on the dosimetry of a scanner, quality control of its operations and the development of a protocol. It allowed us the mastery of the art scanner and participation in all quality controls with appropriate ghosts. CT is a radiographic examination sophisticated and accurate, widely used to screen for various diseases, among other cancer. We worked on the dosimetry of a scanner and we have made simulations with a program called Impact that calculates the CT CTDI and the PDL and compared with values displayed on the console. Similarly, the software calculates the absorbed dose and compared with that calculated by Caldose X. This work is complemented by the development of a protocol with the quality control procedures of the image and dosimetry in chronological order.

  20. Gynecomastia Surgery-Impact on Life Quality: A Prospective Case-Control Study.

    Science.gov (United States)

    Kasielska-Trojan, Anna; Antoszewski, Bogusław

    2017-03-01

    To evaluate the results of surgical treatment of gynecomastia in the context of quality of life and satisfaction after the surgery. Fifty male patients (mean age, 25.1 years [SD = 8 years]) who underwent surgery for gynecomastia and completed both (preoperative and postoperative) stages of the study were included in the analysis. The quality-of-life evaluation instrument was The Short Form-36 Health Survey Questionnaire. Additionally, we used a short questionnaire including 2 questions about patient satisfaction with gynecomastia surgery. The overall change in life satisfaction after gynecomastia surgery was 1 point on Likert scale (sign test, P gynecomastia surgery scored significantly higher than before the procedure in all Short Form-36 Health Survey Questionnaire domains as well as in 2 main scales Psychical and Physical Health. The changes were especially visible for the domain social functioning and a scale Psychical Health (P Gynecomastia surgery significantly improved men's life quality in all aspects and especially in the social aspect and psychical health. This indicates that adult men with gynecomastia are a specific group of patients, in which surgery may result in life quality improvement even over the average scores.

  1. Genetic quality control in mass-reared melon flies

    International Nuclear Information System (INIS)

    Miyatake, T.

    2002-01-01

    Quality control in mass-reared melon flies, Bactrocera cucurbitae, after eradication is discussed, based on the results of artificial selection experiments. First, a brief history of quality control in mass-rearing of insects is described. In practical mass- rearing of melon fly, many traits have already been differentiated between mass-reared and wild flies. These differing traits are reviewed and the factors which caused these differences are considered. It was considered that the differences between wild and mass-reared melon flies depended on the selection pressures from the mass-rearing method. Next, the results of several artificial selection experiments using the melon fly are reviewed. Finally, consideration is given to some correlated responses to artificial selection in mass-rearing. Longevity that is correlated to early fecundity was successfully controlled by artificial selection for reproduction in the mass-rearing system. On the basis of these results, an improved method for quality control in mass-reared melon fly with considerations for quantitative genetics is discussed

  2. 40 CFR 81.176 - San Luis Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false San Luis Intrastate Air Quality Control Region. 81.176 Section 81.176 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.176 San Luis Intrastate Air Quality Control Region. The San Luis Intrastate...

  3. 20. Quality assurance and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Vavrejn, B.

    1989-01-01

    Quality control principles to be applied when taking over and using nuclear medicine instrumentation are given. Such instrumentation includes activity meters, gamma detectors for in vitro measurements (manual or automated instruments), gamma detectors for in vivo measurements (with one or several probes), 'movable' scintigraphs and 'steady' scintigraphs (gamma cameras). (Z.S.)

  4. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  5. Direct product quality control for energy efficient climate controlled transport of agro-material

    NARCIS (Netherlands)

    Verdijck, G.J.C.; Preisig, H.A.; Straten, van G.

    2005-01-01

    A (model-based) Product Quality Controller is presented for climate controlled operations involving agro-material, such as storage and transport. This controller belongs to the class of Model Predictive Controllers and fits in a previously developed hierarchical control structure. The new Product

  6. Using clinical indicators to facilitate quality improvement via the accreditation process: an adaptive study into the control relationship.

    Science.gov (United States)

    Chuang, Sheuwen; Howley, Peter P; Hancock, Stephen

    2013-07-01

    The aim of the study was to determine accreditation surveyors' and hospitals' use and perceived usefulness of clinical indicator reports and the potential to establish the control relationship between the accreditation and reporting systems. The control relationship refers to instructional directives, arising from appropriately designed methods and efforts towards using clinical indicators, which provide a directed moderating, balancing and best outcome for the connected systems. Web-based questionnaire survey. Australian Council on Healthcare Standards' (ACHS) accreditation and clinical indicator programmes. Seventy-three of 306 surveyors responded. Half used the reports always/most of the time. Five key messages were revealed: (i) report use was related to availability before on-site investigation; (ii) report use was associated with the use of non-ACHS reports; (iii) a clinical indicator set's perceived usefulness was associated with its reporting volume across hospitals; (iv) simpler measures and visual summaries in reports were rated the most useful; (v) reports were deemed to be suitable for the quality and safety objectives of the key groups of interested parties (hospitals' senior executive and management officers, clinicians, quality managers and surveyors). Implementing the control relationship between the reporting and accreditation systems is a promising expectation. Redesigning processes to ensure reports are available in pre-survey packages and refined education of surveyors and hospitals on how to better utilize the reports will support the relationship. Additional studies on the systems' theory-based model of the accreditation and reporting system are warranted to establish the control relationship, building integrated system-wide relationships with sustainable and improved outcomes.

  7. Food and Nutrition Services Quality Control Management Program.

    Science.gov (United States)

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  8. Quality of web based information on treatment of depression: cross sectional survey.

    Science.gov (United States)

    Griffiths, K M; Christensen, H

    2000-12-16

    To evaluate quality of web based information on treatment of depression, to identify potential indicators of content quality, and to establish if accountability criteria are indicators of quality. Cross sectional survey. 21 frequently accessed websites about depression. (i) Site characteristics; (ii) quality of content-concordance with evidence based depression guidelines (guideline score), appropriateness of other relevant site information (issues score), and subjective rating of site quality (global score); and (iii) accountability-conformity with core accountability standards (Silberg score) and quality of evidence cited in support of conclusions (level of evidence score). Although the sites contained useful information, their overall quality was poor: the mean guideline, issues, and global scores were only 4.7 (range 0-13) out of 43, 9.8 (6-14) out of 17, and 3 (0.5-7. 5) out of 10 respectively. Sites typically did not cite scientific evidence in support of their conclusions. The guideline score correlated with the two other quality of content measures, but none of the content measures correlated with the Silberg accountability score. Content quality was superior for sites owned by organisations and sites with an editorial board. There is a need for better evidence based information about depression on the web, and a need to reconsider the role of accountability criteria as indicators of site quality and to develop simple valid indicators of quality. Ownership by an organisation and the involvement of a professional editorial board may be useful indicators. The study methodology may be useful for exploring these issues in other health related subjects.

  9. Quality control of nuclear fuels - technical and economic aspects

    International Nuclear Information System (INIS)

    Strasser, A.A.

    1982-01-01

    The qualification and resolution of questions relating to the cost benefit of quality control are based on the interaction of a broad range of technologies and economics. This paper discusses examples of current areas of interest in quality control, and their relationship to the fuel cycle costs. (orig.)

  10. Use of Lot quality assurance sampling surveys to evaluate community health worker performance in rural Zambia: a case of Luangwa district.

    Science.gov (United States)

    Mwanza, Moses; Zulu, Japhet; Topp, Stephanie M; Musonda, Patrick; Mutale, Wilbroad; Chilengi, Roma

    2017-04-17

    The Better Health Outcomes through Mentoring and Assessment (BHOMA) project is a cluster randomized controlled trial aimed at reducing age-standardized mortality rates in three rural districts through involvement of Community Health Workers (CHWs), Traditional Birth Attendants (TBAs), and Neighborhood Health Committees (NHCs). CHWs conduct quarterly surveys on all households using a questionnaire that captures key health events occurring within their catchment population. In order to validate contact with households, we utilize the Lot Quality Assurance Sampling (LQAS) methodology. In this study, we report experiences of applying the LQAS approach to monitor performance of CHWs in Luangwa District. Between April 2011 and December 2013, seven health facilities in Luangwa district were enrolled into the BHOMA project. The health facility catchment areas were divided into 33 geographic zones. Quality assurance was performed each quarter by randomly selecting zones representing about 90% of enrolled catchment areas from which 19 households per zone where also randomly identified. The surveys were conducted by CHW supervisors who had been trained on using the LQAS questionnaire. Information collected included household identity number (ID), whether the CHW visited the household, duration of the most recent visit, and what health information was discussed during the CHW visit. The threshold for success was set at 75% household outreach by CHWs in each zone. There are 4,616 total households in the 33 zones. This yielded a target of 32,212 household visits by community health workers during the 7 survey rounds. Based on the set cutoff point for passing the surveys (at least 75% households confirmed as visited), only one team of CHWs at Luangwa high school failed to reach the target during round 1 of the surveys; all the teams otherwise registered successful visits in all the surveys. We have employed the LQAS methodology for assurance that quarterly surveys were

  11. Neural Network-Based Resistance Spot Welding Control and Quality Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Allen, J.D., Jr.; Ivezic, N.D.; Zacharia, T.

    1999-07-10

    This paper describes the development and evaluation of neural network-based systems for industrial resistance spot welding process control and weld quality assessment. The developed systems utilize recurrent neural networks for process control and both recurrent networks and static networks for quality prediction. The first section describes a system capable of both welding process control and real-time weld quality assessment, The second describes the development and evaluation of a static neural network-based weld quality assessment system that relied on experimental design to limit the influence of environmental variability. Relevant data analysis methods are also discussed. The weld classifier resulting from the analysis successfldly balances predictive power and simplicity of interpretation. The results presented for both systems demonstrate clearly that neural networks can be employed to address two significant problems common to the resistance spot welding industry, control of the process itself, and non-destructive determination of resulting weld quality.

  12. Surveying drinking water quality (Balikhlou River, Ardabil Province, Iran)

    Science.gov (United States)

    Aalipour erdi, Mehdi; Gasempour niari, Hassan; Mousavi Meshkini, Seyyed Reza; Foroug, Somayeh

    2018-03-01

    Considering the importance of Balikhlou River as one of the most important water sources of Ardabil, Nir and Sarein cities, maintaining water quality of this river is the most important goals in provincial and national levels. This river includes a wide area that provides agricultural, industrial and drinking water for the residents. Thus, surveying the quality of this river is important in planning and managing of region. This study examined the quality of river through eight physicochemical parameters (SO4, No3, BOD5, TDS, turbidity, pH, EC, COD) in two high- and low-water seasons by international and national standards in 2013. For this purpose, a review along the river has been done in five stations using t test and SPSS software. Model results showed that the amount difference in TDS and EC with WHO standards, and TDS rates with Iran standards in low-water seasons, pH and EC with WHO standards in high-water seasons, is not significant in high-water season; but for pH and SO4 parameters, turbidity and NO3 in both standards and EC value with WHO standard in low-water season and pH, EC, SO4 parameters and turbidity and NO3 in high-water season have significant difference from 5 to 1%, this shows the ideal limit and lowness of parameters for different usage.

  13. Quality Assurance and Quality Control Practices for Rehabilitation of Sewer and Water Mains

    Science.gov (United States)

    As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued, including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of reha...

  14. Food Service Quality Survey at the University of Zimbabwe Private Canteens

    OpenAIRE

    C. Benhura; S.F. Nyagura; V. Dakwa; P.E. Gombiro; P. Ngwenyama; R. Matanhire; A.Garamukanwa; N. Mudita; J. Zhangazha; W. Mashavira

    2012-01-01

    A quality survey was conducted at private food outlets at the University of Zimbabwe from June 2007 to October 2011. The objective of the study was to assess services offered in relation to customers’ expectations. The other objectives were to assess the reason for many food service providers on campus and weigh the advantages and limitations of such a system. Data collection was effected through observation and questionnaire interviews. Rice with chicken, rice and sadza with beef and beverag...

  15. Choosing a Cluster Sampling Design for Lot Quality Assurance Sampling Surveys

    OpenAIRE

    Hund, Lauren; Bedrick, Edward J.; Pagano, Marcello

    2015-01-01

    Lot quality assurance sampling (LQAS) surveys are commonly used for monitoring and evaluation in resource-limited settings. Recently several methods have been proposed to combine LQAS with cluster sampling for more timely and cost-effective data collection. For some of these methods, the standard binomial model can be used for constructing decision rules as the clustering can be ignored. For other designs, considered here, clustering is accommodated in the design phase. In this paper, we comp...

  16. Quality control of the 113Sn-113mIn generator

    International Nuclear Information System (INIS)

    Morin Zorilla, J.; Olive, E.; Isaac, M.; Cruz, J.

    1989-01-01

    Methods for quality control of 113 Sn- 113m In generators are compared and recommended the most convenient to applicate in hospitals and in more specialized quality control laboratories. The quality of 113 Sn- 113m In generator produced by POLATOM (Poland) is also evaluated. The product met the requirements of the International Pharmacopeia

  17. Sickness absence and psychosocial job quality: an analysis from a longitudinal survey of working Australians, 2005-2012.

    Science.gov (United States)

    Milner, Allison; Butterworth, Peter; Bentley, Rebecca; Kavanagh, Anne M; LaMontagne, Anthony D

    2015-05-15

    Sickness absence is associated with adverse health, organizational, and societal outcomes. Using data from a longitudinal cohort study of working Australians (the Household, Income and Labour Dynamics in Australia (HILDA) Survey), we examined the relationship between changes in individuals' overall psychosocial job quality and variation in sickness absence. The outcome variables were paid sickness absence (yes/no) and number of days of paid sickness absence in the past year (2005-2012). The main exposure variable was psychosocial job quality, measured using a psychosocial job quality index (levels of job control, demands and complexity, insecurity, and perceptions of unfair pay). Analysis was conducted using longitudinal fixed-effects logistic regression models and negative binomial regression models. There was a dose-response relationship between the number of psychosocial job stressors reported by an individual and the odds of paid sickness absence (1 adversity: odds ratio (OR) = 1.26, 95% confidence interval (CI): 1.09, 1.45 (P = 0.002); 2 adversities: OR = 1.28, 95% CI: 1.09, 1.51 (P = 0.002); ≥3 adversities: OR = 1.58, 95% CI: 1.29, 1.94 (P job quality. These results suggest that workplace interventions aiming to improve the quality of work could help reduce sickness absence. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  19. Quality Control of Geological Voxel Models using Experts' Gaze

    NARCIS (Netherlands)

    van Maanen, Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; van der Meulendijk, Michiel J.; van Erp, Johannes Bernardus Fransiscus

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  20. Quality assurance program plan for the radiological survey activities program: Uranium Mill Tailings Remedial Action Project

    International Nuclear Information System (INIS)

    Ramos, S.J.; Berven, B.A.; Little, C.A.

    1986-08-01

    The Radiological Survey Activities (RASA) program at Oak Ridge National Laboratory (ORNL) is responsible for surveying designated sites in the vicinity of 24 inactive mill sites involved in the Department of Energy's (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP). The purpose of these surveys is to provide a recommendation to DOE whether to include or exclude the site from UMTRAP based on whether the onsite residual radioactive material (if any) originated from the former mill sites, and radiation levels onsite are in excess of appropriate Environmental Protection Agency (EPA) criteria. This report describes the quality assurance program plan for the RASA program in conducting all activities related to the UMTRA project. All quality assurance provisions given by the DOE, DOE/UMTRA, and ORNL organizations are integrated into this plan. Specifically, this report identifies the policies and procedures followed in accomplishing the RASA/UMTRAP QA program, identifies those organizational units involved in the implementation of these procedures, and outlines the respective responsibilities of those groups