WorldWideScience

Sample records for qa review qa

  1. QA programme documentation

    International Nuclear Information System (INIS)

    Scheibelt, L.

    1980-01-01

    The present paper deals with the following topics: The need for a documented Q.A. program; Establishing a Q.A. program; Q.A. activities; Fundamental policies; Q.A. policies; Quality objectives Q.A. manual. (orig./RW)

  2. Waste-management QA training and motivation

    International Nuclear Information System (INIS)

    Henderson, J.T.

    1982-01-01

    Early in the development of a QA Program for the Waste Management and Geotechnical Projects Directorate, thought was given to establishing a QA Training Program commensurate with the needs and appropriate to the motivation of a staff of more than 130 scientists and project leaders. These individuals, i.e., researchers rather than hardware designers, had no prior experience with QA programs, and from their perception generally did not believe that such controls had any merit. Therefore, historically proven approaches to QA training had to be quickly modified or totally discarded. For instance, due to the mobility and diversity of backgrounds of personnel at SNL, the QA training program had to accommodate many different levels of QA maturity at any given time. Furthermore, since the application of QA to R and D was continuing to profit from project-specific lessons learned, these improvements in the QA program had to be easily and quickly imparted in the general staff's evolving awareness of QA. A somewhat novel approach to QA training has been developed that draws heavily upon SNL's existing In-Hours Technical Education Courses (INTEC) studio capabilities. This training attempts to accommodate individual staff needs and to ensure the required QA skills and awareness for the diverse types of programs addressed

  3. Analysis of QA audit checklist for equipment suppliers

    International Nuclear Information System (INIS)

    Tian Xuehang

    2012-01-01

    Eleven aspects during the equipment manufacturing by the suppliers, including the guidelines and objectives of quality assurance, management department review, document and record control, staffing and training, design control, procurement control, control of items, process control, inspection and testing control, non-conformance control, and internal and external QA audit, are analyzed in this article. The detailed QA audit checklist on these above mentioned aspects are described and the problems found in real QA audit are listed in this article. (authors)

  4. QA at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Bodnarczuk, M.

    1988-01-01

    This paper opens with a brief overview of the purpose of Fermilab and historical synopsis of the development and current status of quality assurance (QA) at the Laboratory. The paper subsequently addresses some of the more important aspects of interpreting the national standard ANSI/ASME NQA-1 in pure research environments like Fermilab. Highlights of this discussion include, (1) what is hermeneutics and why are hermeneutical considerations relevant for QA, (2) a critical analysis of NQA-1 focussing on teleological aspects of the standard, (3) a description of the hermeneutical approach to NQA-1 used at Fermilab which attempts to capture the true intents of the document without violating the deeply ingrained traditions of quality standards and peer review that have been foundational to the overall success of the paradigms of high-energy physics.

  5. Applying QA to nuclear-development programs

    International Nuclear Information System (INIS)

    Caplinger, W.H.

    1981-12-01

    The application of quality assurance (QA) principles to developmental programs is usually accomplished by tailoring or selecting appropriate requirements from large QA systems. Developmental work at Westinghouse Hanford Company (WHC) covers the complete range from basic research to in-core reactor tests. Desired requirements are selected from the 18 criteria in ANSI/ASME NQA Standard 1 by the cognizant program engineer in conjunction with the quality engineer. These referenced criteria assure that QA for the program is planned, implemented, and maintained. In addition, the WHC QA Manual provides four categories or levels of QA that are assigned to programs or components within the program. These categories are based on safety, reliability, and consequences of failure to provide a cost effective program

  6. A comparative study and analysis of QA requirements for the establishment of a nuclear R and D QA system

    International Nuclear Information System (INIS)

    Kim, Kwan Hyun

    2000-06-01

    This technical report provides recommendations on how to fulfill the requirements of the code in relation to QA activities for nuclear R and D field. This guide applies to the quality assurance (QA) programmes of the responsible organization, i.e. the organization having overall responsibility for the nuclear power plant, as well as to any other separate QA programmes in each stage of a nuclear R and D project. This guide covers QA work on items, services and processes impacting nuclear safety during siting, design, construction, commissioning, operation and decommissioning of nuclear power plants. The impact on safety may occur during the performance of the QA work, or owing to the application of the results of the QA. This guide may, with appropriate modification, also be usefully applied at nuclear installations other than nuclear R and D field

  7. NRC overview: Repository QA

    International Nuclear Information System (INIS)

    Kennedy, J.E.

    1988-01-01

    The US Department of Energy (DOE) is on the threshold of an extensive program for characterizing Yucca Mountain in Nevada to determine if it is a suitable site for the permanent disposal of high-level nuclear waste. Earlier this year, the DOE published the Consultation Draft Site Characterization Plan for the Nevada site, which describes in some detail the studies that need to be performed to determine if the site is acceptable. In the near future, the final site characterization plan (SCP) is expected to be issued and large-scale site characterization activities to begin. The data and analyses that will result from the execution of that plan are expected to be the primary basis for the license application to the US Nuclear Regulatory Commission (NRC). Because of the importance of these data and analyses in the assessment of the suitability of the site and in the demonstration of that suitability in the NRC licensing process, the NRC requires in 10CFR60 that site characterization be performed under a quality assurance (QA) program. The QA program is designed to provide confidence that data are valid, retrievable, and reproducible. The documentation produced by the program will form an important part of the record on which the suitability of the site is judged in licensing. In addition, because the NRC staff can review only a selected portion of the data collected, the staff will need to rely on the system of controls in the DOE QA program

  8. WE-AB-201-00: Treatment Planning System Commissioning and QA

    International Nuclear Information System (INIS)

    2015-01-01

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  9. WE-AB-201-00: Treatment Planning System Commissioning and QA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  10. Portland cement concrete pavement review of QC/QA data 2000 through 2009.

    Science.gov (United States)

    2011-04-01

    This report analyzes the Quality Control/Quality Assurance (QC/QA) data for Portland cement concrete pavement : (PCCP) awarded in the years 2000 through 2009. Analysis of the overall performance of the projects is accomplished by : reviewing the Calc...

  11. Minimum requirements on a QA program in radiation oncology

    International Nuclear Information System (INIS)

    Almond, P.R.

    1996-01-01

    In April, 1994, the American Association of Physicists in Medicine published a ''Comprehensive QA for radiation oncology:'' a report of the AAPM Radiation Therapy Committee. This is a comprehensive QA program which is likely to become the standard for such programs in the United States. The program stresses the interdisciplinary nature of QA in radiation oncology involving the radiation oncologists, the radiotherapy technologies (radiographers), dosimetrists, and accelerator engineers, as well as the medical physicists. This paper describes a comprehensive quality assurance program with the main emphasis on the quality assurance in radiation therapy using a linear accelerator. The paper deals with QA for a linear accelerator and simulator and QA for treatment planning computers. Next the treatment planning process and QA for individual patients is described. The main features of this report, which should apply to QA programs in any country, emphasizes the responsibilities of the medical physicist. (author). 7 refs, 9 tabs

  12. Minimum requirements on a QA program in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Almond, P R [Louisville Univ., Louisville, KY (United States). J.G. Brown Cancer Center

    1996-08-01

    In April, 1994, the American Association of Physicists in Medicine published a ``Comprehensive QA for radiation oncology:`` a report of the AAPM Radiation Therapy Committee. This is a comprehensive QA program which is likely to become the standard for such programs in the United States. The program stresses the interdisciplinary nature of QA in radiation oncology involving the radiation oncologists, the radiotherapy technologies (radiographers), dosimetrists, and accelerator engineers, as well as the medical physicists. This paper describes a comprehensive quality assurance program with the main emphasis on the quality assurance in radiation therapy using a linear accelerator. The paper deals with QA for a linear accelerator and simulator and QA for treatment planning computers. Next the treatment planning process and QA for individual patients is described. The main features of this report, which should apply to QA programs in any country, emphasizes the responsibilities of the medical physicist. (author). 7 refs, 9 tabs.

  13. Statistical process control analysis for patient-specific IMRT and VMAT QA.

    Science.gov (United States)

    Sanghangthum, Taweap; Suriyapee, Sivalee; Srisatit, Somyot; Pawlicki, Todd

    2013-05-01

    This work applied statistical process control to establish the control limits of the % gamma pass of patient-specific intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) quality assurance (QA), and to evaluate the efficiency of the QA process by using the process capability index (Cpml). A total of 278 IMRT QA plans in nasopharyngeal carcinoma were measured with MapCHECK, while 159 VMAT QA plans were undertaken with ArcCHECK. Six megavolts with nine fields were used for the IMRT plan and 2.5 arcs were used to generate the VMAT plans. The gamma (3%/3 mm) criteria were used to evaluate the QA plans. The % gamma passes were plotted on a control chart. The first 50 data points were employed to calculate the control limits. The Cpml was calculated to evaluate the capability of the IMRT/VMAT QA process. The results showed higher systematic errors in IMRT QA than VMAT QA due to the more complicated setup used in IMRT QA. The variation of random errors was also larger in IMRT QA than VMAT QA because the VMAT plan has more continuity of dose distribution. The average % gamma pass was 93.7% ± 3.7% for IMRT and 96.7% ± 2.2% for VMAT. The Cpml value of IMRT QA was 1.60 and VMAT QA was 1.99, which implied that the VMAT QA process was more accurate than the IMRT QA process. Our lower control limit for % gamma pass of IMRT is 85.0%, while the limit for VMAT is 90%. Both the IMRT and VMAT QA processes are good quality because Cpml values are higher than 1.0.

  14. QA manpower requirement for nuclear power plants

    International Nuclear Information System (INIS)

    Link, M.

    1980-01-01

    To ensure the quality of the plant, QA activities are to be performed by the owner, the main contractor, the subcontractors and the Licensing Authority. The responsibilities of the QA-personnel of these organizations comprise as a minimum the control of the quality assurance systems and the proof of the quality requirements. Numbers of the required QA-personnel, designated for different tasks and recommended educational levels and professional qualifications will be given. (orig./RW)

  15. Application of QA geoscience investigations

    International Nuclear Information System (INIS)

    Henderson, J.T.

    1980-01-01

    This paper discusses the evolution of a classical hardware QA program (as currently embodied in DOE/ALO Manual Chapter 08XA; NRC 10CFR Part 50, Appendix B; and other similar documents) into the present geoscience quality assurance programs that address eventual NRC licensing, if required. In the context of this paper, QA will be restricted to the tasks associated with nuclear repositories, i.e. site identification, selection, characterization, verification, and utilization

  16. Follow-up utterances in QA dialogue

    NARCIS (Netherlands)

    van Schooten, B.W.; op den Akker, Hendrikus J.A.

    2006-01-01

    The processing of user follow-up utterances by a QA system is a topic which is still in its infant stages, but enjoys growing interest in the QA community. In this paper, we discuss the broader issues related to handling follow-up utterances in a real-life "information kiosk" setting. With help of a

  17. SU-F-T-275: A Correlation Study On 3D Fluence-Based QA and 2D Dose Measurement-Based QA

    International Nuclear Information System (INIS)

    Liu, S; Mazur, T; Li, H; Green, O; Sun, B; Mutic, S; Yang, D

    2016-01-01

    Purpose: The aim of this paper was to demonstrate the feasibility and creditability of computing and verifying 3D fluencies to assure IMRT and VMAT treatment deliveries, by correlating the passing rates of the 3D fluence-based QA (P(ά)) to the passing rates of 2D dose measurementbased QA (P(Dm)). Methods: 3D volumetric primary fluencies are calculated by forward-projecting the beam apertures and modulated by beam MU values at all gantry angles. We first introduce simulated machine parameter errors (MU, MLC positions, jaw, gantry and collimator) to the plan. Using passing rates of voxel intensity differences (P(Ir)) and 3D gamma analysis (P(γ)), calculated 3D fluencies, calculated 3D delivered dose, and measured 2D planar dose in phantom from the original plan are then compared with those from corresponding plans with errors, respectively. The correlations of these three groups of resultant passing rates, i.e. 3D fluence-based QA (P(ά,Ir) and P(ά,γ)), calculated 3D dose (P(Dc,Ir) and P(Dc,γ)), and 2D dose measurement-based QA (P(Dm,Ir) and P(Dm,γ)), will be investigated. Results: 20 treatment plans with 5 different types of errors were tested. Spearman’s correlations were found between P(ά,Ir) and P(Dc,Ir), and also between P(ά,γ) and P(Dc,γ), with averaged p-value 0.037, 0.065, and averaged correlation coefficient ρ-value 0.942, 0.871 respectively. Using Matrixx QA for IMRT plans, Spearman’s correlations were also obtained between P(ά,Ir) and P(Dm,Ir) and also between P(ά,γ) and P(Dm,γ), with p-value being 0.048, 0.071 and ρ-value being 0.897, 0.779 respectively. Conclusion: The demonstrated correlations improve the creditability of using 3D fluence-based QA for assuring treatment deliveries for IMRT/VMAT plans. Together with advantages of high detection sensitivity and better visualization of machine parameter errors, this study further demonstrates the accuracy and feasibility of 3D fluence based-QA in pre-treatment QA and daily QA. Research

  18. Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    Science.gov (United States)

    Miften, Moyed; Olch, Arthur; Mihailidis, Dimitris; Moran, Jean; Pawlicki, Todd; Molineu, Andrea; Li, Harold; Wijesooriya, Krishni; Shi, Jie; Xia, Ping; Papanikolaou, Nikos; Low, Daniel A

    2018-04-01

    Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review aimed at improving the understanding and consistency of these processes as well as recommendations for methodologies and tolerance limits in patient-specific IMRT QA. The performance of the dose difference/distance-to-agreement (DTA) and γ dose distribution comparison metrics are investigated. Measurement methods are reviewed and followed by a discussion of the pros and cons of each. Methodologies for absolute dose verification are discussed and new IMRT QA verification tools are presented. Literature on the expected or achievable agreement between measurements and calculations for different types of planning and delivery systems are reviewed and analyzed. Tests of vendor implementations of the γ verification algorithm employing benchmark cases are presented. Operational shortcomings that can reduce the γ tool accuracy and subsequent effectiveness for IMRT QA are described. Practical considerations including spatial resolution, normalization, dose threshold, and data interpretation are discussed. Published data on IMRT QA and the clinical experience of the group members are used to develop guidelines and recommendations on tolerance and action limits for IMRT QA. Steps to check failed IMRT QA plans are outlined. Recommendations on delivery methods, data interpretation, dose normalization, the use of γ analysis routines and choice of tolerance limits for IMRT QA are made with focus on detecting differences between calculated and measured doses via the use of robust analysis methods and an in-depth understanding of IMRT verification metrics. The recommendations are intended to improve the IMRT QA process and establish consistent, and comparable IMRT QA

  19. Patient QA systems for rotational radiation therapy

    DEFF Research Database (Denmark)

    Fredh, Anna; Scherman, J.B.; Munck af Rosenschöld, Per Martin

    2013-01-01

    The purpose of the present study was to investigate the ability of commercial patient quality assurance (QA) systems to detect linear accelerator-related errors.......The purpose of the present study was to investigate the ability of commercial patient quality assurance (QA) systems to detect linear accelerator-related errors....

  20. Applications of QA to RandD support of HLW programs

    International Nuclear Information System (INIS)

    Ryder, D.E.

    1988-05-01

    The application of a formal QA program to any discipline or organization can be difficult to achieve and to do so with a research and development organization has special challenges that are somewhat unique. This paper describes how a QA program based upon a national consensus standard (developed for application to the design, construction and operation of nuclear facilities) has been successfully applied to some of the research and development activities in support of the High Level Waste Programs. This description includes a discussion on the importance of being creative when interpreting the QA standard, a brief overview of the QA program that was developed and the results achieved during implementation of the QA program. 4 refs., 4 figs

  1. SU-F-T-226: QA Management for a Large Institution with Multiple Campuses for FMEA

    Energy Technology Data Exchange (ETDEWEB)

    Tang, G; Chan, M; Lovelock, D; Lim, S; Febo, R; DeLauter, J; Both, S; Li, X; Ma, R; Saleh, Z; Song, Y; Tang, X; Xiong, W; Hunt, M; LoSasso, T [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To redesign our radiation therapy QA program with the goal to improve quality, efficiency, and consistency among a growing number of campuses at a large institution. Methods: A QA committee was established with at least one physicist representing each of our six campuses (22 linacs). Weekly meetings were scheduled to advise on and update current procedures, to review end-to-end and other test results, and to prepare composite reports for internal and external audits. QA procedures for treatment and imaging equipment were derived from TG Reports 142 and 66, practice guidelines, and feedback from ACR evaluations. The committee focused on reaching a consensus on a single QA program among all campuses using the same type of equipment and reference data. Since the recommendations for tolerances referenced to baseline data were subject to interpretation in some instances, the committee reviewed the characteristics of all machines and quantified any variations before choosing between treatment planning system (i.e. treatment planning system commissioning data that is representative for all machines) or machine-specific values (i.e. commissioning data of the individual machines) as baseline data. Results: The configured QA program will be followed strictly by all campuses. Inventory of available equipment has been compiled, and additional equipment acquisitions for the QA program are made as needed. Dosimetric characteristics are evaluated for all machines using the same methods to ensure consistency of beam data where possible. In most cases, baseline data refer to treatment planning system commissioning data but machine-specific values are used as reference where it is deemed appropriate. Conclusion: With a uniform QA scheme, variations in QA procedures are kept to a minimum. With a centralized database, data collection and analysis are simplified. This program will facilitate uniformity in patient treatments and analysis of large amounts of QA data campus

  2. Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F., E-mail: sfkry@mdanderson.org [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Molineu, Andrea [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kerns, James R.; Faught, Austin M.; Huang, Jessie Y.; Pulliam, Kiley B.; Tonigan, Jackie [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States); Alvarez, Paola [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Stingo, Francesco [The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States); Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Followill, David S. [Imaging and Radiation Oncology Core at Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); The University of Texas Health Science Center Houston, Graduate School of Biomedical Sciences, Houston, Texas (United States)

    2014-12-01

    Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process.

  3. Institutional Patient-specific IMRT QA Does Not Predict Unacceptable Plan Delivery

    International Nuclear Information System (INIS)

    Kry, Stephen F.; Molineu, Andrea; Kerns, James R.; Faught, Austin M.; Huang, Jessie Y.; Pulliam, Kiley B.; Tonigan, Jackie; Alvarez, Paola; Stingo, Francesco; Followill, David S.

    2014-01-01

    Purpose: To determine whether in-house patient-specific intensity modulated radiation therapy quality assurance (IMRT QA) results predict Imaging and Radiation Oncology Core (IROC)-Houston phantom results. Methods and Materials: IROC Houston's IMRT head and neck phantoms have been irradiated by numerous institutions as part of clinical trial credentialing. We retrospectively compared these phantom results with those of in-house IMRT QA (following the institution's clinical process) for 855 irradiations performed between 2003 and 2013. The sensitivity and specificity of IMRT QA to detect unacceptable or acceptable plans were determined relative to the IROC Houston phantom results. Additional analyses evaluated specific IMRT QA dosimeters and analysis methods. Results: IMRT QA universally showed poor sensitivity relative to the head and neck phantom, that is, poor ability to predict a failing IROC Houston phantom result. Depending on how the IMRT QA results were interpreted, overall sensitivity ranged from 2% to 18%. For different IMRT QA methods, sensitivity ranged from 3% to 54%. Although the observed sensitivity was particularly poor at clinical thresholds (eg 3% dose difference or 90% of pixels passing gamma), receiver operator characteristic analysis indicated that no threshold showed good sensitivity and specificity for the devices evaluated. Conclusions: IMRT QA is not a reasonable replacement for a credentialing phantom. Moreover, the particularly poor agreement between IMRT QA and the IROC Houston phantoms highlights surprising inconsistency in the QA process

  4. Construction QA/QC systems: comparative analysis

    International Nuclear Information System (INIS)

    Willenbrock, J.H.; Shepard, S.

    1980-01-01

    An analysis which compares the quality assurance/quality control (QA/QC) systems adopted in the highway, nuclear power plant, and U.S. Navy construction areas with the traditional quality control approach used in building construction is presented. Full participation and support by the owner as well as the contractor and AE firm are required if a QA/QC system is to succeed. Process quality control, acceptance testing and quality assurance responsibilities must be clearly defined in the contract documents. The owner must audit these responsibilities. A contractor quality control plan, indicating the tasks which will be performed and the fact that QA/QC personnel are independent of project time/cost pressures should be submitted for approval. The architect must develop realistic specifications which consider the natural variability of material. Acceptance criteria based on the random sampling technique should be used. 27 refs

  5. MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

    International Nuclear Information System (INIS)

    Sathiaseelan, V; Thomadsen, B

    2014-01-01

    Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability

  6. MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

    Energy Technology Data Exchange (ETDEWEB)

    Sathiaseelan, V [Northwestern Memorial Hospital, Chicago, IL (United States); Thomadsen, B [University of Wisconsin, Madison, WI (United States)

    2014-06-15

    Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability

  7. WE-AB-201-03: TPS Commissioning and QA: Incorporating the Entire Planning Process

    International Nuclear Information System (INIS)

    Mutic, S.

    2015-01-01

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  8. WE-AB-201-01: Treatment Planning System Commissioning and QA: Challenges and Opportunities

    International Nuclear Information System (INIS)

    Salomons, G.

    2015-01-01

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  9. WE-AB-201-01: Treatment Planning System Commissioning and QA: Challenges and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Salomons, G. [Cancer Center of Southeastern Ontario (Canada)

    2015-06-15

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  10. WE-AB-201-03: TPS Commissioning and QA: Incorporating the Entire Planning Process

    Energy Technology Data Exchange (ETDEWEB)

    Mutic, S. [Washington University School of Medicine (United States)

    2015-06-15

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  11. Application of QA to R ampersand D support of HLW programs

    International Nuclear Information System (INIS)

    Ryder, D.E.

    1988-01-01

    Quality has always been of primary importance in the research and development (R ampersand D) environment. An organization's ability to attract funds for new or continued research is largely dependent on the quality of past performance. However, with the possible exceptions of peer reviews for fund allocation and the referee process prior to publication, past quality assurance (QA) activities were primarily informal good practices. This resulted in standards of acceptable practice that varied from organization to organization. The increasing complexity of R ampersand D projects and the increasing need for project results to be upheld outside the scientific community (i.e., lawsuits and licensing hearings) are encouraging R ampersand D organizations and their clients to adopt more formalized methods for the scientific process and to increase control over support organizations (i.e., suppliers and subcontractors). This has become especially true for R ampersand D organizations involved in the high-level (HLW) projects for a number of years. The PNL began to implement QA program requirements within a few HLW repository preliminary studies in 1978. In 1985, PNL developed a comprehensive QA program for R ampersand D activities in support of two of the proposed repository projects. This QA program was developed by the PNL QA department with a significant amount of support assistance and guidance from PNL upper management, the Basalt Waste Isolation Project (BWIP), and the Salt Repository Program Office (SPRO). The QA program has been revised to add a three-level feature and is currently being implemented on projects sponsored by the Office of Geologic Repositories (DOE/OGR), Repository Technology Program (DOE-CH), Nevada Nuclear Waste Storage Investigation (NNWSI) Project, and other HLW projects

  12. Role of QA in total quality management environment

    International Nuclear Information System (INIS)

    McCarthy, J.B.; Ayres, R.A.

    1992-01-01

    A successful company in today's highly competitive business environment must emphasize quality in all activities at all times. For most companies, this requires a major cultural change to establish appropriate operating attitudes and priorities. A total quality environment is required where quality becomes a way of life, and this process must be carefully managed. It will not be accomplished in a few short months with a simple management pronouncement. Instead, it evolves over a period of years through continuous incremental improvement. This evolution towards total quality requires a dramatic change in the quality assurance (QA) function of most companies. Traditionally, quality was automatically equated to QA and its attendant procedures and personnel. Now, quality is becoming a global concept, and QA can play a significant role in the process. The QA profession must, however, recognize and accept a new role as consultant, coach, and partner in today's total quality game. The days of the hard-line enforcer of procedural requirements are gone

  13. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, Heming; Nelms, Benjamin E.; Tome, Wolfgang A. [Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792 and Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 and Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-10-15

    Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was

  14. Investigations of low qa discharges in the SINP tokamak

    Indian Academy of Sciences (India)

    Low edge safety factor discharges including very low qa (1 qa ... From fluctuation analysis of the external magnetic probe data it has been found that MHD ... To investigate the internal details of these discharges, an internal magnetic probe ...

  15. KINERJA AKADEMIK PASCA SERTIFIKASI AUN-QA PADA PROGRAM STUDI DI INSTITUT PERTANIAN BOGOR

    Directory of Open Access Journals (Sweden)

    Adelyna Adelyna

    2016-05-01

    Full Text Available The aims of the research are to evaluate the academic performance progress of the six study programs of IPB after the certification of AUN-QA. The research was a case study in six study programs that had been certified by AUN-QA until December 2014. This research was conducted with the objectives of defining the relevant indicators of BSC IPB and AUN-QA criteria, analyzing the criteria values of AUN-QA after the AUN-QA certification, analyzing the academic performance based on KPI BSC after the AUN-QA certification, and analyzing the problems in improving academic performance as the basis for the formulation of strategies for improving academic quality. The method used in this research was the balanced scorecard approach (BSC. The results showed that the certification of AUN-QA contains 15 relevant criteria and supports the achievement of BSC IPB. Key performance indicators (KPI BSC IPB supported by the AUN-QA criteria consist of 21 of the 33 indicators of BSC IPB, and 14 of them are relegated to the BSC department indicators. The AUN-QA criteria values on the study program have increased with the highest criterion value in student quality and the lowest one in support staff quality. The weak criteria required to be improved include support staff quality, student assessment, stakeholder feedback, and program specification.Keywords: AUN-QA certification, academic performance, balanced scorecard

  16. QA experience at the University of Wisconsin accredited dosimetry calibration laboratory

    Energy Technology Data Exchange (ETDEWEB)

    DeWard, L.A.; Micka, J.A. [Univ. of Wisconsin, Madison, WI (United States)

    1993-12-31

    The University of Wisconsin Accredited Dosimetry Calibration Laboratory (UW ADCL) employs procedure manuals as part of its Quality Assurance (QA) program. One of these manuals covers the QA procedures and results for all of the UW ADCL measurement equipment. The QA procedures are divided into two main areas: QA for laboratory equipment and QA for external chambers sent for calibration. All internal laboratory equipment is checked and recalibrated on an annual basis, after establishing its consistency on a 6-month basis. QA for external instruments involves checking past calibration history as well as comparing to a range of calibration values for specific instrument models. Generally, the authors find that a chamber will have a variation of less than 0.5 % from previous Co-60 calibration factors, and falls within two standard deviations of previous calibrations. If x-ray calibrations are also performed, the energy response of the chamber is plotted and compared to previous instruments of the same model. These procedures give the authors confidence in the transfer of calibration values from National Institute of Standards and Technology (NIST).

  17. QA experience at the University of Wisconsin accredited dosimetry calibration laboratory

    International Nuclear Information System (INIS)

    DeWard, L.A.; Micka, J.A.

    1993-01-01

    The University of Wisconsin Accredited Dosimetry Calibration Laboratory (UW ADCL) employs procedure manuals as part of its Quality Assurance (QA) program. One of these manuals covers the QA procedures and results for all of the UW ADCL measurement equipment. The QA procedures are divided into two main areas: QA for laboratory equipment and QA for external chambers sent for calibration. All internal laboratory equipment is checked and recalibrated on an annual basis, after establishing its consistency on a 6-month basis. QA for external instruments involves checking past calibration history as well as comparing to a range of calibration values for specific instrument models. Generally, the authors find that a chamber will have a variation of less than 0.5 % from previous Co-60 calibration factors, and falls within two standard deviations of previous calibrations. If x-ray calibrations are also performed, the energy response of the chamber is plotted and compared to previous instruments of the same model. These procedures give the authors confidence in the transfer of calibration values from National Institute of Standards and Technology (NIST)

  18. SU-E-T-11: A Cloud Based CT and LINAC QA Data Management System

    International Nuclear Information System (INIS)

    Wiersma, R; Grelewicz, Z; Belcher, A; Liu, X

    2015-01-01

    Purpose: The current status quo of QA data management consists of a mixture of paper-based forms and spreadsheets for recording the results of daily, monthly, and yearly QA tests for both CT scanners and LINACs. Unfortunately, such systems suffer from a host of problems as, (1) records can be easily lost or destroyed, (2) data is difficult to access — one must physically hunt down records, (3) poor or no means of historical data analysis, and (4) no remote monitoring of machine performance off-site. To address these issues, a cloud based QA data management system was developed and implemented. Methods: A responsive tablet interface that optimizes clinic workflow with an easy-to-navigate interface accessible from any web browser was implemented in HTML/javascript/CSS to allow user mobility when entering QA data. Automated image QA was performed using a phantom QA kit developed in Python that is applicable to any phantom and is currently being used with the Gammex ACR, Las Vegas, Leeds, and Catphan phantoms for performing automated CT, MV, kV, and CBCT QAs, respectively. A Python based resource management system was used to distribute and manage intensive CPU tasks such as QA phantom image analysis or LaTeX-to-PDF QA report generation to independent process threads or different servers such that website performance is not affected. Results: To date the cloud QA system has performed approximately 185 QA procedures. Approximately 200 QA parameters are being actively tracked by the system on a monthly basis. Electronic access to historical QA parameter information was successful in proactively identifying a Linac CBCT scanner’s performance degradation. Conclusion: A fully comprehensive cloud based QA data management system was successfully implemented for the first time. Potential machine performance issues were proactively identified that would have been otherwise missed by a paper or spreadsheet based QA system

  19. SU-E-T-11: A Cloud Based CT and LINAC QA Data Management System

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, R; Grelewicz, Z; Belcher, A; Liu, X [The University of Chicago, Chicago, IL (United States)

    2015-06-15

    Purpose: The current status quo of QA data management consists of a mixture of paper-based forms and spreadsheets for recording the results of daily, monthly, and yearly QA tests for both CT scanners and LINACs. Unfortunately, such systems suffer from a host of problems as, (1) records can be easily lost or destroyed, (2) data is difficult to access — one must physically hunt down records, (3) poor or no means of historical data analysis, and (4) no remote monitoring of machine performance off-site. To address these issues, a cloud based QA data management system was developed and implemented. Methods: A responsive tablet interface that optimizes clinic workflow with an easy-to-navigate interface accessible from any web browser was implemented in HTML/javascript/CSS to allow user mobility when entering QA data. Automated image QA was performed using a phantom QA kit developed in Python that is applicable to any phantom and is currently being used with the Gammex ACR, Las Vegas, Leeds, and Catphan phantoms for performing automated CT, MV, kV, and CBCT QAs, respectively. A Python based resource management system was used to distribute and manage intensive CPU tasks such as QA phantom image analysis or LaTeX-to-PDF QA report generation to independent process threads or different servers such that website performance is not affected. Results: To date the cloud QA system has performed approximately 185 QA procedures. Approximately 200 QA parameters are being actively tracked by the system on a monthly basis. Electronic access to historical QA parameter information was successful in proactively identifying a Linac CBCT scanner’s performance degradation. Conclusion: A fully comprehensive cloud based QA data management system was successfully implemented for the first time. Potential machine performance issues were proactively identified that would have been otherwise missed by a paper or spreadsheet based QA system.

  20. Utility view on QA/QC of WWER-440 fuel design and manufacture

    International Nuclear Information System (INIS)

    Vesely, P.

    1999-01-01

    In this lecture the legislation implements in the Czech Republic, QA/QC system at CEZ, demonstration and development program (purchaser point of view), audit of QA/QC system for fuel design and manufacturing as well as QA/QC records are discussed

  1. Accounting for human factor in QC and QA inspections

    International Nuclear Information System (INIS)

    Goodman, J.

    1986-01-01

    Two types of human error during QC/QA inspection have been identified. The method of accounting for the effects of human error in QC/QA inspections was developed. The result of evaluation of the proportion of discrepant items in the population is affected significantly by human factor

  2. SU-F-T-287: A Preliminary Study On Patient Specific VMAT Verification Using a Phosphor-Screen Based Geometric QA System (Raven QA)

    International Nuclear Information System (INIS)

    Lee, M; Yi, B; Wong, J; Ding, K

    2016-01-01

    Purpose: The RavenQA system (LAP Laser, Germany) is a QA device with a phosphor screen detector for performing the QA tasks of TG-142. This study tested if it is feasible to use the system for the patient specific QA of the Volumetric Modulated Arc Therapy (VMAT). Methods: Water equivalent material (5cm) is attached to the front of the detector plate of the RavenQA for dosimetry purpose. Then the plate is attached to the gantry to synchronize the movement between the detector and the gantry. Since the detector moves together with gantry, The ’Reset gantry to 0’ function of the Eclipse planning system (Varian, CA) is used to simulate the measurement situation when calculating dose of the detector plate. The same gantry setup is used when delivering the treatment beam for feasibility test purposes. Cumulative dose is acquired for each arc. The optical scatter component of each captured image from the CCD camera is corrected by deconvolving the 2D spatial invariant optical scatter kernel (OSK). We assume that the OSK is a 2D isotropic point spread function with inverse-squared decrease as a function of radius from the center. Results: Three cases of VMAT plans including head & neck, whole pelvis and abdomen-pelvis are tested. Setup time for measurements was less than 5 minutes. Passing rates of absolute gamma were 99.3, 98.2, 95.9 respectively for 3%/3mm criteria and 96.2, 97.1, 86.4 for 2%/2mm criteria. The abdomen-pelvis field has long treatment fields, 37cm, which are longer than the detector plate (25cm). This plan showed relatively lower passing rate than other plans. Conclusion: An algorithm for IMRT/VMAT verification using the RavenQA has been developed and tested. The model of spatially invariant OSK works well for deconvolution purpose. It is proved that the RavenQA can be used for the patient specific verification of VMAT. This work is funded in part by a Maryland Industrial Partnership Program grant to University of Maryland and to JPLC who owns the

  3. Physics acceptance and QA procedures for IMRT

    International Nuclear Information System (INIS)

    LoSasso, T.; Ling, C.

    2001-01-01

    Full text: Intensity modulated radiation therapy (IMRT) may improve tumor control without compromising normal tissues by facilitating higher, more conformal tumor doses relative to 3D CRT. Intensity modulation (IM) is now possible with inverse planning and radiation delivery using dynamic multileaf collimation. Compared to 3D CRT, certain components in the IMRT process are more obscure to the user. Thus, special quality assurance procedures are required. Hardware and software are still relatively new to many users, and the potential for error is unknown. The relationship between monitor unit (MU) setting and radiation dose for IM beams is much more complex than for non-IM fields. The leaf sequence computer files, which control the MLC position as a function of MU, are large and do not lend themselves to simple manual verification. The 'verification' port film for each IM treatment field, usually obtained with the MLC set at the extreme leaf positions for that field to outline the entire irradiated area, does not verify the intensity modulation pattern. Finally, in IMRT using DMLC (the so-called sliding window technique), a small error in the window (or gap) width will lead to a significant dose error. In earlier papers, we provided an evaluation of the mechanical and dosimetric aspects in the use of a MLC in the dynamic mode. Mechanical tolerances are significantly tighter for DMLC than for static MLC treatments. Transmission through the leaves and through rounded leaf ends and head scatter were shown to be significant to the accuracy of radiation dose delivery using DMLC. With these considerations, we concluded that the present DMLC hardware and software are effective for routine clinical implementation, provided that a carefully designed routine QA procedure is followed to assure the normality of operation. In our earlier studies, an evaluation of the long-term stability of DMLC operation had not yet been performed. This paper describes the current status of our

  4. WE-B-BRD-03: MR QA/QC for MRgRT

    Energy Technology Data Exchange (ETDEWEB)

    Layman, R. [Ohio State Univ (United States)

    2015-06-15

    The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

  5. Concept of a QA-programme for the recipient country, goals and measures

    International Nuclear Information System (INIS)

    Thomas, F.W.

    1986-04-01

    Ordering, design and erection of a NPP is a complex business even in a country with experience. Therefore a QA-Programme can be helpful to do the work in a planned and organized manner. In the case of a recipient country the use of administrative QA-measures seems to be a necessary support, especially for the ordering company. It is not the intention of the QA-Programme to say what to do, and so it cannot solve ''political'' questions of the business, but the QA-Programme can say how the work has to be done to bring it to a good end. This lecture points out the most important and interesting questions in the phase of establishing a QA-Programme. Examples of solutions are given. (author). 13 figs

  6. Current Status of QA For Nuclear Power Plants in Japan

    International Nuclear Information System (INIS)

    Nagoshi, Hitohiko

    1986-01-01

    It is the current status of QA and our QA experiences with nuclear power plants against the background of the Japanese social and business environment. Accordingly, in 1972, 'The Guidance for Quality Assurance in Construction of Nuclear Power Plants' based on U. S. 10CEF50 Appendix B, was published by the Japan Electric Association. 'Jug-4101 The Guide for Quality Assurance of Nuclear Power Plants' has been prepared by referring to the IAEA QA code. The Guide has been accepted by the Japanese nuclear industry and applied to the QA programs of every organization concerned therewith. The Japanese approach to higher quality will naturally be different from that of other countries because of Japan's cultural, social, and economic conditions. Even higher quality is being aimed at through the LWR Improvement and Standardization Program and coordinated quality assurance efforts

  7. The GSPC: Newest Franchise in al-Qa'ida's Global Jihad

    National Research Council Canada - National Science Library

    Boudali, Lianne K

    2007-01-01

    ... of support in Europe. The alignment of the GSPC with al Qa ida represents a significant change in the group's strategy, however, its decision to join al Qa ida's global jihad should be understood as an act of desperation...

  8. Poster - Thur Eve - 29: Detecting changes in IMRT QA using statistical process control.

    Science.gov (United States)

    Drever, L; Salomons, G

    2012-07-01

    Statistical process control (SPC) methods were used to analyze 239 measurement based individual IMRT QA events. The selected IMRT QA events were all head and neck (H&N) cases with 70Gy in 35 fractions, and all prostate cases with 76Gy in 38 fractions planned between March 2009 and 2012. The results were used to determine if the tolerance limits currently being used for IMRT QA were able to indicate if the process was under control. The SPC calculations were repeated for IMRT QA of the same type of cases that were planned after the treatment planning system was upgraded from Eclipse version 8.1.18 to version 10.0.39. The initial tolerance limits were found to be acceptable for two of the three metrics tested prior to the upgrade. After the upgrade to the treatment planning system the SPC analysis found that the a priori limits were no longer capable of indicating control for 2 of the 3 metrics analyzed. The changes in the IMRT QA results were clearly identified using SPC, indicating that it is a useful tool for finding changes in the IMRT QA process. Routine application of SPC to IMRT QA results would help to distinguish unintentional trends and changes from the random variation in the IMRT QA results for individual plans. © 2012 American Association of Physicists in Medicine.

  9. WE-AB-201-02: TPS Commissioning and QA: A Process Orientation and Application of Control Charts

    International Nuclear Information System (INIS)

    Sharpe, M.

    2015-01-01

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  10. WE-AB-201-02: TPS Commissioning and QA: A Process Orientation and Application of Control Charts

    Energy Technology Data Exchange (ETDEWEB)

    Sharpe, M. [The Princess Margaret Cancer Centre - UHN (Canada)

    2015-06-15

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  11. Graded approach for establishment of QA requirements for Type B packaging of radioactive material

    International Nuclear Information System (INIS)

    Fabian, R.R.; Woodruff, K.C.

    1988-01-01

    A study that was conducted by the Nuclear Regulatory Commission for the U.S. Congress to assess the effectiveness of quality assurance (QA) activities has demonstrated a need to modify and improve the application of QA requirements for the nuclear industry. As a result, the packaging community, along with the nuclear industry as a whole, has taken action to increase the efficacy of the QA function. The results of the study indicate that a graded approach for establishing QA requirements is the preferred method. The essence of the graded approach is the establishment of applicable QA requirements to an extent consistent with the importance to safety of an item, component, system, or activity. This paper describes the process that is used to develop the graded approach for QA requirements pertaining to Type B packaging

  12. Improvement of QA/QC activities in the construction of nuclear power plant

    International Nuclear Information System (INIS)

    Jinji Tomita; Shigetaka Tomaru

    1987-01-01

    Construction of commercial nuclear power plants in Japan started at around 1965. In this presentation are described quality assurance (QA) activities of a plant supplier who is a manufacturer of the key components as well. The QA activities until now are divided into several periods of the construction history in Japan. First term is 1960's when the QA activities are featured as the study and implementation through the construction of imported plants. Since then technologies and procedures of our own have been established and improved for the construction of high reliability plants. Our present QA activities are based on the active reflection of those lessons learned of past experiences. (author)

  13. QA in the design and fabrication of the TMI-2 rail cask

    International Nuclear Information System (INIS)

    Hayes, G.R.

    1988-01-01

    EGandG Idaho, Inc., acting on behalf of the US Department of Energy, is responsible for transporting core debris from Three Mile Island-Unit 2 to the Idaho National Engineering Laboratory. Transportation of the debris is being accomplished using an NRC licensed container, called the NuPac 125-B. This paper describes the NuPac 125-B Rail Cask and the quality assurance (QA) requirements for that system. Also discussed are the QA roles of the various organizations involved in designing, building, inspecting and testing the NuPac 125-B. The paper presents QA/QC systems implemented during the design, procurement, and fabrication of the cask to assure compliance with all applicable technical codes, standards and regulations. It also goes beyond the requirements aspect and describes unique QA/QC measures employed to assure that the cask was built with minimum QA problems. Finally, the lessons learned from the NuPac 125-B project is discussed. 4 refs., 4 figs

  14. THE IMPORTANCE OF A SUCCESSFUL QUALITY ASSURANCE (QA) PROGRAM FROM A RESEARCH MANAGER'S PERSPECTIVE

    Science.gov (United States)

    The paper discusses the Air Pollution Prevention and Control Division's Quality Assurance (QA) program and the approaches used to meet QA requirements in the Division. The presentation is a technical manager's perspective of the Division's requirements for and approach to QA in i...

  15. QA [quality assurance] at Fermilab; the hermeneutics of NQA-1

    International Nuclear Information System (INIS)

    Bodnarczuk, M.

    1988-06-01

    This paper opens with a brief overview of the purpose of Fermilab and a historical synopsis of the development and current status of quality assurance (QA) at the Laboratory. The paper subsequently addresses some of the more important aspects of interpreting the national standard ANSI/ASME NQA-1 in pure research environments like Fermilab. Highlights of this discussion include, what is hermeneutics and why are hermeneutical considerations relevant for QA, a critical analysis of NQA-1 focussing on teleological aspects of the standard, a description of the hermeneutical approach to NQA-1 used at Fermilab which attempts to capture the true intents of the document without violating the deeply ingrained traditions of quality standards and peer review that have been foundational to the overall success of the paradigms of high-energy physics

  16. QA (quality assurance) at Fermilab; the hermeneutics of NQA-1

    Energy Technology Data Exchange (ETDEWEB)

    Bodnarczuk, M.

    1988-06-01

    This paper opens with a brief overview of the purpose of Fermilab and a historical synopsis of the development and current status of quality assurance (QA) at the Laboratory. The paper subsequently addresses some of the more important aspects of interpreting the national standard ANSI/ASME NQA-1 in pure research environments like Fermilab. Highlights of this discussion include, what is hermeneutics and why are hermeneutical considerations relevant for QA, a critical analysis of NQA-1 focussing on teleological aspects of the standard, a description of the hermeneutical approach to NQA-1 used at Fermilab which attempts to capture the true intents of the document without violating the deeply ingrained traditions of quality standards and peer review that have been foundational to the overall success of the paradigms of high-energy physics.

  17. The unusually strong hydrogen bond between the carbonyl of Q(A) and His M219 in the Rhodobacter sphaeroides reaction center is not essential for efficient electron transfer from Q(A)(-) to Q(B).

    Science.gov (United States)

    Breton, Jacques; Lavergne, Jérôme; Wakeham, Marion C; Nabedryk, Eliane; Jones, Michael R

    2007-06-05

    In native reaction centers (RCs) from photosynthetic purple bacteria the primary quinone (QA) and the secondary quinone (QB) are interconnected via a specific His-Fe-His bridge. In Rhodobacter sphaeroides RCs the C4=O carbonyl of QA forms a very strong hydrogen bond with the protonated Npi of His M219, and the Ntau of this residue is in turn coordinated to the non-heme iron atom. The second carbonyl of QA is engaged in a much weaker hydrogen bond with the backbone N-H of Ala M260. In previous work, a Trp side chain was introduced by site-directed mutagenesis at the M260 position in the RC of Rb. sphaeroides, resulting in a complex that is completely devoid of QA and therefore nonfunctional. A photochemically competent derivative of the AM260W mutant was isolated that contains a Cys side chain at the M260 position (denoted AM260(W-->C)). In the present work, the interactions between the carbonyl groups of QA and the protein in the AM260(W-->C) suppressor mutant have been characterized by light-induced FTIR difference spectroscopy of the photoreduction of QA. The QA-/QA difference spectrum demonstrates that the strong interaction between the C4=O carbonyl of QA and His M219 is lost in the mutant, and the coupled CO and CC modes of the QA- semiquinone are also strongly perturbed. In parallel, a band assigned to the perturbation of the C5-Ntau mode of His M219 upon QA- formation in the native RC is lacking in the spectrum of the mutant. Furthermore, a positive band between 2900 and 2400 cm-1 that is related to protons fluctuating within a network of highly polarizable hydrogen bonds in the native RC is reduced in amplitude in the mutant. On the other hand, the QB-/QB FTIR difference spectrum is essentially the same as for the native RC. The kinetics of electron transfer from QA- to QB were measured by the flash-induced absorption changes at 780 nm. Compared to native RCs the absorption transients are slowed by a factor of about 2 for both the slow phase (in the

  18. WE-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA II

    Energy Technology Data Exchange (ETDEWEB)

    Childress, N [Mobius Medical Management, LLC,, Houston, TX (United States); Murray, B [ZapIT Medical, Dublin, OH (Ireland)

    2014-06-15

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Using DoseLab to Perform TG-142 Imaging QA The goals of this session will be to present a clinical overview of acquiring images for TG-142 Imaging QA, as well as analyzing and evaluating results using DoseLab software. DoseLab supports planar imaging QA analysis using almost any QA phantom provided by numerous vendors. General advantages and disadvantages of selecting each of these phantoms will be briefly summarized. Best practices for selecting image acquisition parameters will be presented. A demonstration of using DoseLab software to perform a series of TG-142 tests will be performed. We will disuss why DoseLab uses its own set of imaging QA formulas, and why imaging QA measurement values of the same nominal properties will vary between TG- 142 software packages. Because TG-142 does not specify baseline and tolerance values for imaging QA, the presentation will recommend performing the manufacturer's acceptance test procedure to validate the equipment is functioning correctly. Afterwards, results can be obtained using the clinic's selected set of phantoms, image acquisition parameters, and TG-142 software to set proper baseline values. This presentation will highlight the reasons why comparing imaging QA results can be trickier than comparing linear accelerator treatment results and what physicists should keep in mind when comparing imaging QA results for different machines. Physicists are often unsure of the next step when there is an issue discovered during Imaging QA. Therefore, a few common examples

  19. WE-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA II

    International Nuclear Information System (INIS)

    Childress, N; Murray, B

    2014-01-01

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Using DoseLab to Perform TG-142 Imaging QA The goals of this session will be to present a clinical overview of acquiring images for TG-142 Imaging QA, as well as analyzing and evaluating results using DoseLab software. DoseLab supports planar imaging QA analysis using almost any QA phantom provided by numerous vendors. General advantages and disadvantages of selecting each of these phantoms will be briefly summarized. Best practices for selecting image acquisition parameters will be presented. A demonstration of using DoseLab software to perform a series of TG-142 tests will be performed. We will disuss why DoseLab uses its own set of imaging QA formulas, and why imaging QA measurement values of the same nominal properties will vary between TG- 142 software packages. Because TG-142 does not specify baseline and tolerance values for imaging QA, the presentation will recommend performing the manufacturer's acceptance test procedure to validate the equipment is functioning correctly. Afterwards, results can be obtained using the clinic's selected set of phantoms, image acquisition parameters, and TG-142 software to set proper baseline values. This presentation will highlight the reasons why comparing imaging QA results can be trickier than comparing linear accelerator treatment results and what physicists should keep in mind when comparing imaging QA results for different machines. Physicists are often unsure of the next step when there is an issue discovered during Imaging QA. Therefore, a few common examples

  20. WE-G-BRA-02: SafetyNet: Automating Radiotherapy QA with An Event Driven Framework

    International Nuclear Information System (INIS)

    Hadley, S; Kessler, M; Litzenberg, D; Lee, C; Irrer, J; Chen, X; Acosta, E; Weyburne, G; Lam, K; Younge, K; Matuszak, M; Keranen, W; Covington, E; Moran, J

    2015-01-01

    Purpose: Quality assurance is an essential task in radiotherapy that often requires many manual tasks. We investigate the use of an event driven framework in conjunction with software agents to automate QA and eliminate wait times. Methods: An in house developed subscription-publication service, EventNet, was added to the Aria OIS to be a message broker for critical events occurring in the OIS and software agents. Software agents operate without user intervention and perform critical QA steps. The results of the QA are documented and the resulting event is generated and passed back to EventNet. Users can subscribe to those events and receive messages based on custom filters designed to send passing or failing results to physicists or dosimetrists. Agents were developed to expedite the following QA tasks: Plan Revision, Plan 2nd Check, SRS Winston-Lutz isocenter, Treatment History Audit, Treatment Machine Configuration. Results: Plan approval in the Aria OIS was used as the event trigger for plan revision QA and Plan 2nd check agents. The agents pulled the plan data, executed the prescribed QA, stored the results and updated EventNet for publication. The Winston Lutz agent reduced QA time from 20 minutes to 4 minutes and provided a more accurate quantitative estimate of radiation isocenter. The Treatment Machine Configuration agent automatically reports any changes to the Treatment machine or HDR unit configuration. The agents are reliable, act immediately, and execute each task identically every time. Conclusion: An event driven framework has inverted the data chase in our radiotherapy QA process. Rather than have dosimetrists and physicists push data to QA software and pull results back into the OIS, the software agents perform these steps immediately upon receiving the sentinel events from EventNet. Mr Keranen is an employee of Varian Medical Systems. Dr. Moran’s institution receives research support for her effort for a linear accelerator QA project from

  1. WE-G-BRA-02: SafetyNet: Automating Radiotherapy QA with An Event Driven Framework

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, S; Kessler, M [The University of Michigan, Ann Arbor, MI (United States); Litzenberg, D [Univ Michigan, Ann Arbor, MI (United States); Lee, C; Irrer, J; Chen, X; Acosta, E; Weyburne, G; Lam, K; Younge, K; Matuszak, M [University of Michigan, Ann Arbor, MI (United States); Keranen, W [Varian Medical Systems, Palo Alto, CA (United States); Covington, E [University of Michigan Hospital and Health System, Ann Arbor, MI (United States); Moran, J [Univ Michigan Medical Center, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: Quality assurance is an essential task in radiotherapy that often requires many manual tasks. We investigate the use of an event driven framework in conjunction with software agents to automate QA and eliminate wait times. Methods: An in house developed subscription-publication service, EventNet, was added to the Aria OIS to be a message broker for critical events occurring in the OIS and software agents. Software agents operate without user intervention and perform critical QA steps. The results of the QA are documented and the resulting event is generated and passed back to EventNet. Users can subscribe to those events and receive messages based on custom filters designed to send passing or failing results to physicists or dosimetrists. Agents were developed to expedite the following QA tasks: Plan Revision, Plan 2nd Check, SRS Winston-Lutz isocenter, Treatment History Audit, Treatment Machine Configuration. Results: Plan approval in the Aria OIS was used as the event trigger for plan revision QA and Plan 2nd check agents. The agents pulled the plan data, executed the prescribed QA, stored the results and updated EventNet for publication. The Winston Lutz agent reduced QA time from 20 minutes to 4 minutes and provided a more accurate quantitative estimate of radiation isocenter. The Treatment Machine Configuration agent automatically reports any changes to the Treatment machine or HDR unit configuration. The agents are reliable, act immediately, and execute each task identically every time. Conclusion: An event driven framework has inverted the data chase in our radiotherapy QA process. Rather than have dosimetrists and physicists push data to QA software and pull results back into the OIS, the software agents perform these steps immediately upon receiving the sentinel events from EventNet. Mr Keranen is an employee of Varian Medical Systems. Dr. Moran’s institution receives research support for her effort for a linear accelerator QA project from

  2. IMRT QA using machine learning: A multi-institutional validation.

    Science.gov (United States)

    Valdes, Gilmer; Chan, Maria F; Lim, Seng Boh; Scheuermann, Ryan; Deasy, Joseph O; Solberg, Timothy D

    2017-09-01

    To validate a machine learning approach to Virtual intensity-modulated radiation therapy (IMRT) quality assurance (QA) for accurately predicting gamma passing rates using different measurement approaches at different institutions. A Virtual IMRT QA framework was previously developed using a machine learning algorithm based on 498 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3 mm with 10% threshold at Institution 1. An independent set of 139 IMRT measurements from a different institution, Institution 2, with QA data based on portal dosimetry using the same gamma index, was used to test the mathematical framework. Only pixels with ≥10% of the maximum calibrated units (CU) or dose were included in the comparison. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. The methodology predicted passing rates within 3% accuracy for all composite plans measured using diode-array detectors at Institution 1, and within 3.5% for 120 of 139 plans using portal dosimetry measurements performed on a per-beam basis at Institution 2. The remaining measurements (19) had large areas of low CU, where portal dosimetry has a larger disagreement with the calculated dose and as such, the failure was expected. These beams need further modeling in the treatment planning system to correct the under-response in low-dose regions. Important features selected by Lasso to predict gamma passing rates were as follows: complete irradiated area outline (CIAO), jaw position, fraction of MLC leafs with gaps smaller than 20 or 5 mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted average irregularity factor, and duty cycle. We have demonstrated that Virtual IMRT QA can predict passing rates using different measurement techniques and across multiple

  3. Technical Note: Response time evolution of XR-QA2 GafChromic™ film models.

    Science.gov (United States)

    Aldelaijan, Saad; Tomic, Nada; Papaconstadopoulos, Pavlos; Schneider, James; Seuntjens, Jan; Shih, Shelley; Lewis, David; Devic, Slobodan

    2018-01-01

    To evaluate the response of the newest XR-QA2 GafChromic™ film model in terms of postexposure signal growth and energy response in comparison with the older XR-QA (Version 2) model. Pieces of film were irradiated to air kerma in air values up to 12 cGy with several beam qualities (5.3-8.25 mm Al) commonly used for CT scanning. Film response was scored in terms of net reflectance from scanned film images at various points in time postirradiation ranging from 1 to 7 days and 5 months postexposure. To reconstruct the measurement signal changes with postirradiation delay, we irradiated one film piece and then scanned it at different point times starting from 2" min and up to 3 days postexposure. For all beam qualities and dose range investigated, it appears that the XR-QA2 film signal completely saturated after 15 h. Compared to 15 h postirradiation scanning time, the observed variation in net reflectance were 3%, 2%, and 1% for film scanned 2" min, 20 min, and 3 h after exposure, respectively, which is well within the measurement uncertainty of the XR-QA2 based reference radiochromic film dosimetry system. A comparison between the XR-QA (Version 2) and the XR-QA2 film response after several months (relative to their responses after 24 h) show differences in up to 8% and 1% for each film model respectively. The replacement of cesium bromide in the older XR-QA (Version 2) film model with bismuth oxide in the newer XR-QA2 film, while keeping the same single sensitive layer structure, lead to a significantly more stable postexposure response. © 2017 American Association of Physicists in Medicine.

  4. Multimodal follow-up questions to multimodal answers in a QA system

    NARCIS (Netherlands)

    van Schooten, B.W.; op den Akker, Hendrikus J.A.

    2007-01-01

    We are developing a dialogue manager (DM) for a multimodal interactive Question Answering (QA) system. Our QA system presents answers using text and pictures, and the user may pose follow-up questions using text or speech, while indicating screen elements with the mouse. We developed a corpus of

  5. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    International Nuclear Information System (INIS)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A.

    2011-01-01

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa. Conclusions: There is a lack of correlation between

  6. TU-C-BRE-01: KEYNOTE PRESENTATION - Emerging Frontiers in IMRT QA

    Energy Technology Data Exchange (ETDEWEB)

    Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2014-06-15

    As IMRT treatment processes advance and mature, so must the quality assurance processes being used to validate their delivery. In some respects, treatment delivery advancements (e.g. VMAT) have out-paced QA advancements. The purpose of this session is to describe new processes that are being implemented to bring IMRT QA up-to-date with the treatment delivery advances. It would explore emerging IMRT QA paradigms, including requirements-based IMRT QA which necessitates definition of delivery errors (e.g. patient dose error, leaf positioning error) and development of processes to ensure reliable error detection. Engineeringbased QA approaches, including use of IMRT treatment delivery process trees, fault tree analysis and failure modes effects analysis would be described. Approaches to detect errors such as (1) during treatment delivery validation using exit fluence detectors (e.g. EPIDs); (2) analysis of treatment delivery via use of machine parameter log files; (3) dose recalculation using (3a) treatment planning system; (3b) record-and-verify; or (3c) entrance and exit fluence measurement parameters would be explained. The relative advantages and disadvantages of each method would be discussed. Schemes for error classification and root cause analysis would be described – steps which are essential for future error prevention. For each QA method, testing procedures and results would be presented indicating the types of errors that can be detected, those that cannot be detected, and the reliability of the error detection method (for example determined via ROC analysis). For speakers, we are seeking to engage non-commercially biased experts. Those listed below are a sub-sample of possible qualified individuals.

  7. TU-C-BRE-01: KEYNOTE PRESENTATION - Emerging Frontiers in IMRT QA

    International Nuclear Information System (INIS)

    Siebers, J

    2014-01-01

    As IMRT treatment processes advance and mature, so must the quality assurance processes being used to validate their delivery. In some respects, treatment delivery advancements (e.g. VMAT) have out-paced QA advancements. The purpose of this session is to describe new processes that are being implemented to bring IMRT QA up-to-date with the treatment delivery advances. It would explore emerging IMRT QA paradigms, including requirements-based IMRT QA which necessitates definition of delivery errors (e.g. patient dose error, leaf positioning error) and development of processes to ensure reliable error detection. Engineeringbased QA approaches, including use of IMRT treatment delivery process trees, fault tree analysis and failure modes effects analysis would be described. Approaches to detect errors such as (1) during treatment delivery validation using exit fluence detectors (e.g. EPIDs); (2) analysis of treatment delivery via use of machine parameter log files; (3) dose recalculation using (3a) treatment planning system; (3b) record-and-verify; or (3c) entrance and exit fluence measurement parameters would be explained. The relative advantages and disadvantages of each method would be discussed. Schemes for error classification and root cause analysis would be described – steps which are essential for future error prevention. For each QA method, testing procedures and results would be presented indicating the types of errors that can be detected, those that cannot be detected, and the reliability of the error detection method (for example determined via ROC analysis). For speakers, we are seeking to engage non-commercially biased experts. Those listed below are a sub-sample of possible qualified individuals

  8. Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy.

    Science.gov (United States)

    Rah, Jeong-Eun; Shin, Dongho; Manger, Ryan P; Kim, Tae Hyun; Oh, Do Hoon; Kim, Dae Yong; Kim, Gwe-Ya

    2018-02-01

    To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances. The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine the steps that need focus for improving the patient-specific QA. The patient-specific range QA plans were selected according to seven treatment site groups, a total of 1437 cases. The process capability index, C pm was used to guide the tolerance design of patient site-specific range. For prostate field, our results suggested that the patient range measurements were capable at the current tolerance level of ±1 mm in clinical proton plans. For other site-specific ranges, we analyzed that the tolerance tends to be overdesigned to insufficient process capability calculated by the patient-specific QA data. The customized tolerances were calculated for treatment sites. Control charts were constructed to simulate the patient QA time before and after the new tolerances were implemented. It is found that the total simulation QA time was decreased on average of approximately 20% after establishing new site-specific range tolerances. We simulated the financial impact of this project. The QA failure for whole process in proton therapy would lead up to approximately 30% increase in total cost. DMAIC framework can be used to provide an effective QA by setting customized tolerances. When tolerance design is customized, the quality is reasonably balanced with time and cost demands. © 2017 American Association of Physicists in Medicine.

  9. Impact and payback of a QA/QC program for steam-water chemistry

    International Nuclear Information System (INIS)

    Lerman, S.I.; Wilson, D.

    1992-01-01

    QA/QC programs for analytical laboratories and in-line instrumentation are essential if we are to have any faith in the data they produce. When the analytes are at trace levels, as they frequently are in a steam-water cycle, the importance of QA/QC increases by an order of magnitude. The cost and resources of such a program, although worth it, are frequently underestimated. QA/QC is much more than running a standard several times a week. This paper will discuss some of the essential elements of such a program, compare them to the cost, and point out the impact of not having such a program. RP-2712-3 showed how essential QA/QC is to understand the limitations of instruments doing trace analysis of water. What it did not do, nor was it intended to, is discuss how good reliability can be in your own plant. QA programs that include training of personnel, written procedures, and comprehensive maintenance and inventory programs ensure optimum performance of chemical monitors. QC samples run regularly allow plant personnel to respond to poor performance in a timely manner, appropriate to plant demands. Proper data management establishes precision information necessary to determine how good our measurements are. Generally, the plant has the advantage of a central laboratory to perform corroborative analysis, and a comprehensive QA/QC program will integrate the plant monitoring operations with the central lab. Where trace analysis is concerned, attention to detail becomes paramount. Instrument performance may be below expected levels, and instruments are probably being run at the bottom end of their optimum range. Without QA/QC the plant manager can have no confidence in analytical results. Poor steam-water chemistry can go unnoticed, causing system deterioration. We can't afford to wait for another RP-2712-3 to tell us how good our data is

  10. Process control analysis of IMRT QA: implications for clinical trials

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Rice, Roger K; Yoo, Sua; Court, Laurence E; McMillan, Sharon K; Russell, J Donald; Pacyniak, John M; Woo, Milton K; Basran, Parminder S; Boyer, Arthur L; Bonilla, Claribel

    2008-01-01

    The purpose of this study is two-fold: first is to investigate the process of IMRT QA using control charts and second is to compare control chart limits to limits calculated using the standard deviation (σ). Head and neck and prostate IMRT QA cases from seven institutions in both academic and community settings are considered. The percent difference between the point dose measurement in phantom and the corresponding result from the treatment planning system (TPS) is used for analysis. The average of the percent difference calculations defines the accuracy of the process and is called the process target. This represents the degree to which the process meets the clinical goal of 0% difference between the measurements and TPS. IMRT QA process ability defines the ability of the process to meet clinical specifications (e.g. 5% difference between the measurement and TPS). The process ability is defined in two ways: (1) the half-width of the control chart limits, and (2) the half-width of ±3σ limits. Process performance is characterized as being in one of four possible states that describes the stability of the process and its ability to meet clinical specifications. For the head and neck cases, the average process target across institutions was 0.3% (range: -1.5% to 2.9%). The average process ability using control chart limits was 7.2% (range: 5.3% to 9.8%) compared to 6.7% (range: 5.3% to 8.2%) using standard deviation limits. For the prostate cases, the average process target across the institutions was 0.2% (range: -1.8% to 1.4%). The average process ability using control chart limits was 4.4% (range: 1.3% to 9.4%) compared to 5.3% (range: 2.3% to 9.8%) using standard deviation limits. Using the standard deviation to characterize IMRT QA process performance resulted in processes being preferentially placed in one of the four states. This is in contrast to using control charts for process characterization where the IMRT QA processes were spread over three of the

  11. Lymphocytes Negatively Regulate NK Cell Activity via Qa-1b following Viral Infection

    Directory of Open Access Journals (Sweden)

    Haifeng C. Xu

    2017-11-01

    Full Text Available NK cells can reduce anti-viral T cell immunity during chronic viral infections, including infection with the lymphocytic choriomeningitis virus (LCMV. However, regulating factors that maintain the equilibrium between productive T cell and NK cell immunity are poorly understood. Here, we show that a large viral load resulted in inhibition of NK cell activation, which correlated with increased expression of Qa-1b, a ligand for inhibitory NK cell receptors. Qa-1b was predominantly upregulated on B cells following LCMV infection, and this upregulation was dependent on type I interferons. Absence of Qa-1b resulted in increased NK cell-mediated regulation of anti-viral T cells following viral infection. Consequently, anti-viral T cell immunity was reduced in Qa-1b- and NKG2A-deficient mice, resulting in increased viral replication and immunopathology. NK cell depletion restored anti-viral immunity and virus control in the absence of Qa-1b. Taken together, our findings indicate that lymphocytes limit NK cell activity during viral infection in order to promote anti-viral T cell immunity.

  12. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A. [Canis Lupus LLC and Department of Human Oncology, University of Wisconsin, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Departments of Human Oncology, Medical Physics, and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-02-15

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa

  13. SU-E-T-468: Implementation of the TG-142 QA Process for Seven Linacs with Enhanced Beam Conformance

    Energy Technology Data Exchange (ETDEWEB)

    Woollard, J; Ayan, A; DiCostanzo, D; Grzetic, S; Hessler, J; Gupta, N [OH State University, Columbus, OH (United States)

    2015-06-15

    Purpose: To develop a TG-142 compliant QA process for 7 Varian TrueBeam linear accelerators (linacs) with enhanced beam conformance and dosimetrically matched beam models. To ensure consistent performance of all 7 linacs, the QA process should include a common set of baseline values for use in routine QA on all linacs. Methods: The TG 142 report provides recommended tests, tolerances and frequencies for quality assurance of medical accelerators. Based on the guidance provided in the report, measurement tests were developed to evaluate each of the applicable parameters listed for daily, monthly and annual QA. These tests were then performed on each of our 7 new linacs as they came on line at our institution. Results: The tolerance values specified in TG-142 for each QA test are either absolute tolerances (i.e. ±2mm) or require a comparison to a baseline value. The results of our QA tests were first used to ensure that all 7 linacs were operating within the suggested tolerance values provided in TG −142 for those tests with absolute tolerances and that the performance of the linacs was adequately matched. The QA test results were then used to develop a set of common baseline values for those QA tests that require comparison to a baseline value at routine monthly and annual QA. The procedures and baseline values were incorporated into a spreadsheets for use in monthly and annual QA. Conclusion: We have developed a set of procedures for daily, monthly and annual QA of our linacs that are consistent with the TG-142 report. A common set of baseline values was developed for routine QA tests. The use of this common set of baseline values for comparison at monthly and annual QA will ensure consistent performance of all 7 linacs.

  14. SU-E-T-468: Implementation of the TG-142 QA Process for Seven Linacs with Enhanced Beam Conformance

    International Nuclear Information System (INIS)

    Woollard, J; Ayan, A; DiCostanzo, D; Grzetic, S; Hessler, J; Gupta, N

    2015-01-01

    Purpose: To develop a TG-142 compliant QA process for 7 Varian TrueBeam linear accelerators (linacs) with enhanced beam conformance and dosimetrically matched beam models. To ensure consistent performance of all 7 linacs, the QA process should include a common set of baseline values for use in routine QA on all linacs. Methods: The TG 142 report provides recommended tests, tolerances and frequencies for quality assurance of medical accelerators. Based on the guidance provided in the report, measurement tests were developed to evaluate each of the applicable parameters listed for daily, monthly and annual QA. These tests were then performed on each of our 7 new linacs as they came on line at our institution. Results: The tolerance values specified in TG-142 for each QA test are either absolute tolerances (i.e. ±2mm) or require a comparison to a baseline value. The results of our QA tests were first used to ensure that all 7 linacs were operating within the suggested tolerance values provided in TG −142 for those tests with absolute tolerances and that the performance of the linacs was adequately matched. The QA test results were then used to develop a set of common baseline values for those QA tests that require comparison to a baseline value at routine monthly and annual QA. The procedures and baseline values were incorporated into a spreadsheets for use in monthly and annual QA. Conclusion: We have developed a set of procedures for daily, monthly and annual QA of our linacs that are consistent with the TG-142 report. A common set of baseline values was developed for routine QA tests. The use of this common set of baseline values for comparison at monthly and annual QA will ensure consistent performance of all 7 linacs

  15. MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

    International Nuclear Information System (INIS)

    Valdes, G; Scheuermann, R; Solberg, T; Chan, M; Deasy, J

    2016-01-01

    Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

  16. MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

    Energy Technology Data Exchange (ETDEWEB)

    Valdes, G; Scheuermann, R; Solberg, T [University of Pennsylvania, Philadelphia, PA (United States); Chan, M; Deasy, J [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

  17. QA CLASSIFICATION ANALYSIS OF GROUND SUPPORT SYSTEMS

    International Nuclear Information System (INIS)

    D. W. Gwyn

    1996-01-01

    The purpose and objective of this analysis is to determine if the permanent function Ground Support Systems (CI: BABEEOOOO) are quality-affecting items and if so, to establish the appropriate Quality Assurance (QA) classification

  18. Peer review, basic research, and engineering: Defining a role for QA professionals in basic research environments

    Energy Technology Data Exchange (ETDEWEB)

    Bodnarczuk, M.

    1989-02-01

    Within the context of doing basic research, this paper seeks to answer four major questions: (1) What is the authority structure of science. (2) What is peer review. (3) Where is the interface between basic physics research and standard engineering. and (4) Given the conclusions to the first three questions, what is the role of the QA professional in a basic research environment like Fermilab. 23 refs.

  19. QA/QC - Practices and procedures in WWER fuel management

    International Nuclear Information System (INIS)

    Keselica, M.

    1999-01-01

    Construction time schedule and commissioning (unit by unit) of the NPP Dukovany as well as structure of electricity generation in the CEZ in 1998 are reviewed. History of QA/QC system establishment and rules (system standards) as well as organization chart of the NPP Dukovany and quality manual of reactor physics department are presented. Standards of worker's qualification and nuclear fuel inspections are discussed. Fuel reliability indicators are presented

  20. SU-F-T-285: Evaluation of a Patient DVH-Based IMRT QA System

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, H; Redler, G; Chu, J; Turian, J [Rush University Medical Center, Chicago, IL (United States)

    2016-06-15

    Purpose: To evaluate the clinical performance of a patient DVH-based QA system for prostate VMAT QA. Methods: Mobius3D(M3D) is a QA software with an independent beam model and dose engine. The MobiusFX(MFX) add-on predicts patient dose using treatment machine log files. We commissioned the Mobius beam model in two steps. First, the stock beam model was customized using machine commissioning data, then verified against the TPS with 12 simple phantom plans and 7 clinical 3D plans. Secondly, the Dosimetric Leaf Gap(DLG) in the Mobius model was fine-tuned for VMAT treatment based on ion chamber measurements for 6 clinical VMAT plans. Upon successful commissioning, we retrospectively performed IMRT QA for 12 VMAT plans with the Mobius system as well as the ArcCHECK-3DVH system. Selected patient DVH values (PTV D95, D50; Bladder D2cc, Dmean; Rectum D2cc) were compared between TPS, M3D, MFX, and 3DVH. Results: During the first commissioning step, TPS and M3D calculated target Dmean for 3D plans agree within 0.7%±0.7%, with 3D gamma passing rates of 98%±2%. In the second commissioning step, the Mobius DLG was adjusted by 1.2mm from the stock value, reducing the average difference between MFX calculation and ion chamber measurement from 3.2% to 0.1%. In retrospective prostate VMAT QA, 5 of 60 MFX calculated DVH values have a deviation greater than 5% compared to TPS. One large deviation at high dose level was identified as a potential QA failure. This echoes the 3DVH QA result, which identified 2 instances of large DVH deviation on the same structure. For all DVH’s evaluated, M3D and MFX show high level of agreement (0.1%±0.2%), indicating that the observed deviation is likely from beam modelling differences rather than delivery errors. Conclusion: Mobius system provides a viable solution for DVH based VMAT QA, with the capability of separating TPS and delivery errors.

  1. SU-F-T-285: Evaluation of a Patient DVH-Based IMRT QA System

    International Nuclear Information System (INIS)

    Zhen, H; Redler, G; Chu, J; Turian, J

    2016-01-01

    Purpose: To evaluate the clinical performance of a patient DVH-based QA system for prostate VMAT QA. Methods: Mobius3D(M3D) is a QA software with an independent beam model and dose engine. The MobiusFX(MFX) add-on predicts patient dose using treatment machine log files. We commissioned the Mobius beam model in two steps. First, the stock beam model was customized using machine commissioning data, then verified against the TPS with 12 simple phantom plans and 7 clinical 3D plans. Secondly, the Dosimetric Leaf Gap(DLG) in the Mobius model was fine-tuned for VMAT treatment based on ion chamber measurements for 6 clinical VMAT plans. Upon successful commissioning, we retrospectively performed IMRT QA for 12 VMAT plans with the Mobius system as well as the ArcCHECK-3DVH system. Selected patient DVH values (PTV D95, D50; Bladder D2cc, Dmean; Rectum D2cc) were compared between TPS, M3D, MFX, and 3DVH. Results: During the first commissioning step, TPS and M3D calculated target Dmean for 3D plans agree within 0.7%±0.7%, with 3D gamma passing rates of 98%±2%. In the second commissioning step, the Mobius DLG was adjusted by 1.2mm from the stock value, reducing the average difference between MFX calculation and ion chamber measurement from 3.2% to 0.1%. In retrospective prostate VMAT QA, 5 of 60 MFX calculated DVH values have a deviation greater than 5% compared to TPS. One large deviation at high dose level was identified as a potential QA failure. This echoes the 3DVH QA result, which identified 2 instances of large DVH deviation on the same structure. For all DVH’s evaluated, M3D and MFX show high level of agreement (0.1%±0.2%), indicating that the observed deviation is likely from beam modelling differences rather than delivery errors. Conclusion: Mobius system provides a viable solution for DVH based VMAT QA, with the capability of separating TPS and delivery errors.

  2. Technical report on comparative analysis of ASME QA requirements and ISO series

    International Nuclear Information System (INIS)

    Kim, Kwan Hyun

    2000-06-01

    This technical report provides the differences on the QA requirement ASME and ISO in nuclear fields. This report applies to the quality assurance(QA) programmes of the design of two requirement. The organization having overall responsibility for the nuclear design, preservation, fabrication shall be described in this report in each stage of design project

  3. Radiotherapy QA of the DAHANCA 19 protocol

    DEFF Research Database (Denmark)

    Samsøe, E.; Andersen, E.; Hansen, C. R.

    2015-01-01

    Purpose/Objective: It has been demonstrated that nonadherence to protocol-specified radiotherapy (RT) requirements is associated with reduced survival, local control and potentially increased toxicity [1]. Thus, quality assurance (QA) of RT is important when evaluating the results of clinical...

  4. TU-E-BRB-02: DIR QA Options and Research Development

    International Nuclear Information System (INIS)

    Kirby, N.

    2015-01-01

    Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations

  5. TU-E-BRB-02: DIR QA Options and Research Development

    Energy Technology Data Exchange (ETDEWEB)

    Kirby, N. [University of Texas HSC SA (United States)

    2015-06-15

    Deformable image registration (DIR) is developing rapidly and is poised to substantially improve dose fusion accuracy for adaptive and retreatment planning and motion management and PET fusion to enhance contour delineation for treatment planning. However, DIR dose warping accuracy is difficult to quantify, in general, and particularly difficult to do so on a patient-specific basis. As clinical DIR options become more widely available, there is an increased need to understand the implications of incorporating DIR into clinical workflow. Several groups have assessed DIR accuracy in clinically relevant scenarios, but no comprehensive review material is yet available. This session will also discuss aspects of the AAPM Task Group 132 on the Use of Image Registration and Data Fusion Algorithms and Techniques in Radiotherapy Treatment Planning official report, which provides recommendations for DIR clinical use. We will summarize and compare various commercial DIR software options, outline successful clinical techniques, show specific examples with discussion of appropriate and inappropriate applications of DIR, discuss the clinical implications of DIR, provide an overview of current DIR error analysis research, review QA options and research phantom development and present TG-132 recommendations. Learning Objectives: Compare/contrast commercial DIR software and QA options Overview clinical DIR workflow for retreatment To understand uncertainties introduced by DIR Review TG-132 proposed recommendations.

  6. The implementing of the training, examination and qualification for QA auditor

    International Nuclear Information System (INIS)

    Ma Xiaozheng; Han Peicong; Zhang Zhongyuan; Zhu Guoliang

    2007-01-01

    China Power Investment Corporation has implemented the training, examination and qualification for QA auditor based on the related requirements of the nuclear safety documents. The bases, planning of the procedure, implementing procedure and suggestions for implementing the training, examination and qualification are described in this article. That can be used as the reference for implementing the training, examination and qualification for QA auditor, as well as for establishment of the related guide. (authors)

  7. Application of QA grading to Yucca Mountain Site Characterization Project items and activities

    International Nuclear Information System (INIS)

    Murthy, R.B.; Smith, S.C.

    1991-01-01

    Grading is the act of selecting the quality assurance (QA) measures necessary to develop and maintain confidence in the quality of an item or activity. The list of QA measures from which this selection is made are the 20 criteria of the Yucca Mountain Site Characterization Project Quality Assurance Requirements Document

  8. Beam dynamics of mixed high intensity highly charged ion Beams in the Q/A selector

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.H., E-mail: zhangxiaohu@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Yuan, Y.J.; Yin, X.J.; Qian, C.; Sun, L.T. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Du, H.; Li, Z.S.; Qiao, J.; Wang, K.D. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhao, H.W.; Xia, J.W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2017-06-11

    Electron cyclotron resonance (ECR) ion sources are widely used in heavy ion accelerators for their advantages in producing high quality intense beams of highly charged ions. However, it exists challenges in the design of the Q/A selection systems for mixed high intensity ion beams to reach sufficient Q/A resolution while controlling the beam emittance growth. Moreover, as the emittance of beam from ECR ion sources is coupled, the matching of phase space to post accelerator, for a wide range of ion beam species with different intensities, should be carefully studied. In this paper, the simulation and experimental results of the Q/A selection system at the LECR4 platform are shown. The formation of hollow cross section heavy ion beam at the end of the Q/A selector is revealed. A reasonable interpretation has been proposed, a modified design of the Q/A selection system has been committed for HIRFL-SSC linac injector. The features of the new design including beam simulations and experiment results are also presented.

  9. SU-C-BRD-03: Closing the Loop On Virtual IMRT QA

    International Nuclear Information System (INIS)

    Valdes, G; Scheuermann, R; Y, H C.; Olszanski, A; Bellerive, M; Solberg, T

    2015-01-01

    Purpose: To develop an algorithm that predicts a priori IMRT QA passing rates. Methods: 416 IMRT plans from all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam linacs (Varian Medical Systems, Palo Alto, CA). The 3%/3mm and 2%/2mm local distance to agreement (DTA) were recorded during clinical operations using a commercial 2D diode array (MapCHECK 2, Sun Nuclear, Melbourne, FL). Each plan was characterized by 37 metrics that describe different failure modes between the calculated and measured dose. Machine-learning algorithms (MLAs) were trained to learn the relation between the plan characteristics and each passing rate. Minimization of the cross validated error, together with maximum a posteriori estimation (MAP), were used to choose the model parameters. Results: 3%/3mm local DTA can be predicted with an error smaller than 3% for 98% of the plans. For the remaining 2% of plans, the residual error was within 5%. For 2%/2mm local DTA passing rates, 96% percent of the plans were successfully predicted with an error smaller than 5%. All high-risk plans that failed the 2%/2mm local criteria were correctly identified by the algorithm. The most important metric to describe the passing rates was determined to be the MU per Gray (modulation factor). Conclusions: Logs files and independent dose calculations have been suggested as possible substitutes for measurement based IMRT QA. However, none of these methods answer the fundamental question of whether a plan can be delivered with a clinically acceptable error given the limitations of the linacs and the treatment planning system. Predicting the IMRT QA passing rates a priori closes that loop. For additional robustness, virtual IMRT QA can be combined with Linac QA and log file analysis to confirm appropriate delivery

  10. SU-C-BRD-03: Closing the Loop On Virtual IMRT QA

    Energy Technology Data Exchange (ETDEWEB)

    Valdes, G; Scheuermann, R; Y, H C.; Olszanski, A; Bellerive, M; Solberg, T [University of Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To develop an algorithm that predicts a priori IMRT QA passing rates. Methods: 416 IMRT plans from all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam linacs (Varian Medical Systems, Palo Alto, CA). The 3%/3mm and 2%/2mm local distance to agreement (DTA) were recorded during clinical operations using a commercial 2D diode array (MapCHECK 2, Sun Nuclear, Melbourne, FL). Each plan was characterized by 37 metrics that describe different failure modes between the calculated and measured dose. Machine-learning algorithms (MLAs) were trained to learn the relation between the plan characteristics and each passing rate. Minimization of the cross validated error, together with maximum a posteriori estimation (MAP), were used to choose the model parameters. Results: 3%/3mm local DTA can be predicted with an error smaller than 3% for 98% of the plans. For the remaining 2% of plans, the residual error was within 5%. For 2%/2mm local DTA passing rates, 96% percent of the plans were successfully predicted with an error smaller than 5%. All high-risk plans that failed the 2%/2mm local criteria were correctly identified by the algorithm. The most important metric to describe the passing rates was determined to be the MU per Gray (modulation factor). Conclusions: Logs files and independent dose calculations have been suggested as possible substitutes for measurement based IMRT QA. However, none of these methods answer the fundamental question of whether a plan can be delivered with a clinically acceptable error given the limitations of the linacs and the treatment planning system. Predicting the IMRT QA passing rates a priori closes that loop. For additional robustness, virtual IMRT QA can be combined with Linac QA and log file analysis to confirm appropriate delivery.

  11. Common QA/QM Criteria for Multinational Vendor Inspection

    International Nuclear Information System (INIS)

    2014-01-01

    This VICWG document provides the 'Common QA/QM Criteria' which will be used in Multinational Vendor Inspection. The 'Common QA/QM Criteria' provides the basic consideration when performing the Vendor Inspection. These criteria has been developed in conformity with International Codes and Standards such as IAEA, ISO and so on that MDEP member countries adopted. The purpose of the VICWG is to establish areas of co-operation in the Vendor Inspection practices among MDEP member countries as described in the MDEP issue-specific Terms of Reference (ToR). As part of this, from the beginning, a survey was performed to understand and to identify areas of commonality and differences between regulatory practices of member countries in the area of vendor inspection. The VICWG also collaborated by performing Witnessed Inspections and Joint Inspections. Through these activities, it was recognized that member countries commonly apply the IAEA safety standard (GS-R-3) to the vendor inspection criteria, and almost ail European member countries apply the ISO standard (ISO9001). In the US, the NRC regulatory requirement in 10 CFR, Part 50, Appendix B is used. South Korea uses the same criteria as in the US. As a result of the information obtained, a comparison table between codes and standards (IAEAGS-R-3, ISO 9001:2008.10CFR50 Appendix Band ASME NQA-1) has been developed in order to inform the development of 'Common QA/QM Criteria'. The result is documented in Table 1, 'MDEP CORE QA/QM Requirement and Comparison between Codes and Standards'. In addition, each country's criteria were compared with the US 10CFR50 Appendix B as a template. Table 2 shows VICWG Survey on Quality Assurance Program Requirements. Through these activities above, we considered that the core requirements should be consistent with both IAEA safety standard and ISO standard, and considered that the common requirements in the US 10CFR50 Appendix B used to the survey

  12. On the use of biomathematical models in patient-specific IMRT dose QA

    Energy Technology Data Exchange (ETDEWEB)

    Zhen Heming [UT Southwestern Medical Center, Dallas, Texas 75390 (United States); Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Tome, Wolfgang A. [Department of Radiation Oncology, Division of Medical Physics, Montefiore Medical Center and Institute of Onco-Physics, Albert Einstein College of Medicine, Bronx, New York 10461 (United States)

    2013-07-15

    Purpose: To investigate the use of biomathematical models such as tumor control probability (TCP) and normal tissue complication probability (NTCP) as new quality assurance (QA) metrics.Methods: Five different types of error (MLC transmission, MLC penumbra, MLC tongue and groove, machine output, and MLC position) were intentionally induced to 40 clinical intensity modulated radiation therapy (IMRT) patient plans (20 H and N cases and 20 prostate cases) to simulate both treatment planning system errors and machine delivery errors in the IMRT QA process. The changes in TCP and NTCP for eight different anatomic structures (H and N: CTV, GTV, both parotids, spinal cord, larynx; prostate: CTV, rectal wall) were calculated as the new QA metrics to quantify the clinical impact on patients. The correlation between the change in TCP/NTCP and the change in selected DVH values was also evaluated. The relation between TCP/NTCP change and the characteristics of the TCP/NTCP curves is discussed.Results:{Delta}TCP and {Delta}NTCP were summarized for each type of induced error and each structure. The changes/degradations in TCP and NTCP caused by the errors vary widely depending on dose patterns unique to each plan, and are good indicators of each plan's 'robustness' to that type of error.Conclusions: In this in silico QA study the authors have demonstrated the possibility of using biomathematical models not only as patient-specific QA metrics but also as objective indicators that quantify, pretreatment, a plan's robustness with respect to possible error types.

  13. On the use of biomathematical models in patient-specific IMRT dose QA

    International Nuclear Information System (INIS)

    Zhen Heming; Nelms, Benjamin E.; Tomé, Wolfgang A.

    2013-01-01

    Purpose: To investigate the use of biomathematical models such as tumor control probability (TCP) and normal tissue complication probability (NTCP) as new quality assurance (QA) metrics.Methods: Five different types of error (MLC transmission, MLC penumbra, MLC tongue and groove, machine output, and MLC position) were intentionally induced to 40 clinical intensity modulated radiation therapy (IMRT) patient plans (20 H and N cases and 20 prostate cases) to simulate both treatment planning system errors and machine delivery errors in the IMRT QA process. The changes in TCP and NTCP for eight different anatomic structures (H and N: CTV, GTV, both parotids, spinal cord, larynx; prostate: CTV, rectal wall) were calculated as the new QA metrics to quantify the clinical impact on patients. The correlation between the change in TCP/NTCP and the change in selected DVH values was also evaluated. The relation between TCP/NTCP change and the characteristics of the TCP/NTCP curves is discussed.Results:ΔTCP and ΔNTCP were summarized for each type of induced error and each structure. The changes/degradations in TCP and NTCP caused by the errors vary widely depending on dose patterns unique to each plan, and are good indicators of each plan's “robustness” to that type of error.Conclusions: In this in silico QA study the authors have demonstrated the possibility of using biomathematical models not only as patient-specific QA metrics but also as objective indicators that quantify, pretreatment, a plan's robustness with respect to possible error types

  14. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Steers, Jennifer M. [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 and Physics and Biology in Medicine IDP, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095 (United States); Fraass, Benedick A., E-mail: benedick.fraass@cshs.org [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 (United States)

    2016-04-15

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose

  15. DeepQA: improving the estimation of single protein model quality with deep belief networks.

    Science.gov (United States)

    Cao, Renzhi; Bhattacharya, Debswapna; Hou, Jie; Cheng, Jianlin

    2016-12-05

    Protein quality assessment (QA) useful for ranking and selecting protein models has long been viewed as one of the major challenges for protein tertiary structure prediction. Especially, estimating the quality of a single protein model, which is important for selecting a few good models out of a large model pool consisting of mostly low-quality models, is still a largely unsolved problem. We introduce a novel single-model quality assessment method DeepQA based on deep belief network that utilizes a number of selected features describing the quality of a model from different perspectives, such as energy, physio-chemical characteristics, and structural information. The deep belief network is trained on several large datasets consisting of models from the Critical Assessment of Protein Structure Prediction (CASP) experiments, several publicly available datasets, and models generated by our in-house ab initio method. Our experiments demonstrate that deep belief network has better performance compared to Support Vector Machines and Neural Networks on the protein model quality assessment problem, and our method DeepQA achieves the state-of-the-art performance on CASP11 dataset. It also outperformed two well-established methods in selecting good outlier models from a large set of models of mostly low quality generated by ab initio modeling methods. DeepQA is a useful deep learning tool for protein single model quality assessment and protein structure prediction. The source code, executable, document and training/test datasets of DeepQA for Linux is freely available to non-commercial users at http://cactus.rnet.missouri.edu/DeepQA/ .

  16. A Chatbot as a Natural Web Interface to Arabic Web QA

    Directory of Open Access Journals (Sweden)

    Bayan Abu Shawar

    2011-03-01

    Full Text Available In this paper, we describe a way to access Arabic Web Question Answering (QA corpus using a chatbot, without the need for sophisticated natural language processing or logical inference. Any Natural Language (NL interface to Question Answer (QA system is constrained to reply with the given answers, so there is no need for NL generation to recreate well-formed answers, or for deep analysis or logical inference to map user input questions onto this logical ontology; simple (but large set of pattern-template matching rules will suffice. In previous research, this approach works properly with English and other European languages. In this paper, we try to see how the same chatbot will react in terms of Arabic Web QA corpus. Initial results shows that 93% of answers were correct, but because of a lot of characteristics related to Arabic language, changing Arabic questions into other forms may lead to no answers.

  17. Web Implementation of Quality Assurance (QA) for X-ray Units in Balkanic Medical Institutions.

    Science.gov (United States)

    Urošević, Vlade; Ristić, Olga; Milošević, Danijela; Košutić, Duško

    2015-08-01

    Diagnostic radiology is the major contributor to the total dose of the population from all artificial sources. In order to reduce radiation exposure and optimize diagnostic x-ray image quality, it is necessary to increase the quality and efficiency of quality assurance (QA) and audit programs. This work presents a web application providing completely new QA solutions for x-ray modalities and facilities. The software gives complete online information (using European standards) with which the corresponding institutions and individuals can evaluate and control a facility's Radiation Safety and QA program. The software enables storage of all data in one place and sharing the same information (data), regardless of whether the measured data is used by an individual user or by an authorized institution. The software overcomes the distance and time separation of institutions and individuals who take part in QA. Upgrading the software will enable assessment of the medical exposure level to ionizing radiation.

  18. TU-FG-201-01: 18-Month Clinical Experience of a Linac Daily Quality Assurance (QA) Solution Using Only EPID and OBI

    Energy Technology Data Exchange (ETDEWEB)

    Cai, B; Sun, B; Yaddanapudi, S; Goddu, S; Li, H; Caruthers, D; Kavanaugh, J; Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: To describe the clinical use of a Linear Accelerator (Linac) DailyQA system with only EPID and OBI. To assess the reliability over an 18-month period and improve the robustness of this system based on QA failure analysis. Methods: A DailyQA solution utilizing an in-house designed phantom, combined EPID and OBI image acquisitions, and a web-based data analysis and reporting system was commissioned and used in our clinic to measure geometric, dosimetry and imaging components of a Varian Truebeam Linac. During an 18-month period (335 working days), the Daily QA results, including the output constancy, beam flatness and symmetry, uniformity, TPR20/10, MV and KV imaging quality, were collected and analyzed. For output constancy measurement, an independent monthly QA system with an ionization chamber (IC) and annual/incidental TG51 measurements with ADCL IC were performed and cross-compared to Daily QA system. Thorough analyses were performed on the recorded QA failures to evaluate the machine performance, optimize the data analysis algorithm, adjust the tolerance setting and improve the training procedure to prevent future failures. Results: A clinical workflow including beam delivery, data analysis, QA report generation and physics approval was established and optimized to suit daily clinical operation. The output tests over the 335 working day period cross-correlated with the monthly QA system within 1.3% and TG51 results within 1%. QA passed with one attempt on 236 days out of 335 days. Based on the QA failures analysis, the Gamma criteria is revised from (1%, 1mm) to (2%, 1mm) considering both QA accuracy and efficiency. Data analysis algorithm is improved to handle multiple entries for a repeating test. Conclusion: We described our 18-month clinical experience on a novel DailyQA system using only EPID and OBI. The long term data presented demonstrated the system is suitable and reliable for Linac daily QA.

  19. SU-E-CAMPUS-T-04: Statistical Process Control for Patient-Specific QA in Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    LAH, J [Myongji Hospital, Goyangsi, Gyeonggi-do (Korea, Republic of); SHIN, D [National Cancer Center, Goyangsi, Gyeonggi-do (Korea, Republic of); Kim, G [UCSD Medical Center, La Jolla, CA (United States)

    2014-06-15

    Purpose: To evaluate and improve the reliability of proton QA process, to provide an optimal customized level using the statistical process control (SPC) methodology. The aim is then to suggest the suitable guidelines for patient-specific QA process. Methods: We investigated the constancy of the dose output and range to see whether it was within the tolerance level of daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to suggest the suitable guidelines for patient-specific QA in proton beam by using process capability indices. In this study, patient QA plans were classified into 6 treatment sites: head and neck (41 cases), spinal cord (29 cases), lung (28 cases), liver (30 cases), pancreas (26 cases), and prostate (24 cases). Results: The deviations for the dose output and range of daily QA process were ±0.84% and ±019%, respectively. Our results show that the patient-specific range measurements are capable at a specification limit of ±2% in all treatment sites except spinal cord cases. In spinal cord cases, comparison of process capability indices (Cp, Cpm, Cpk ≥1, but Cpmk ≤1) indicated that the process is capable, but not centered, the process mean deviates from its target value. The UCL (upper control limit), CL (center line) and LCL (lower control limit) for spinal cord cases were 1.37%, −0.27% and −1.89%, respectively. On the other hands, the range differences in prostate cases were good agreement between calculated and measured values. The UCL, CL and LCL for prostate cases were 0.57%, −0.11% and −0.78%, respectively. Conclusion: SPC methodology has potential as a useful tool to customize an optimal tolerance levels and to suggest the suitable guidelines for patient-specific QA in clinical proton beam.

  20. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Dieterich, S.

    2016-01-01

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  1. TH-A-BRC-00: New Task Groups for External Beam QA: An Overview

    International Nuclear Information System (INIS)

    2016-01-01

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  2. TH-A-BRC-00: New Task Groups for External Beam QA: An Overview

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  3. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Dieterich, S. [UC Davis Medical Center (United States)

    2016-06-15

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  4. Discussion of Regulatory Guide 7.10, emphasizing the graded approach for establishing QA programs

    International Nuclear Information System (INIS)

    Gordon, L.; Lake, W.H.

    1983-01-01

    To assist applicants in establishing an acceptable QA program to meet the programmatic elements of Appendix E to 10 CFR Part 71, Regulatory Guide 7.10 was developed. Regulatory Guide 7.10 is organized in three self-contained ANNEXES. Guidance applicable to designer/fabricators, to users, and users of radiographic devices are in separate annexes. QA programs for packaging to transport radioactive material are similar in regard to the various operations a licensee may be involved in. However, the appropriate QA/QC effort to verify the program elements may vary significantly. This is referred to as the graded approach. Appendix A in the guide addresses the graded approach

  5. The quality assurance process for the ARTSCAN head and neck study - A practical interactive approach for QA in 3DCRT and IMRT

    International Nuclear Information System (INIS)

    Johansson, Karl-Axel; Nilsson, Per; Zackrisson, Bjoern; Ohlson, Birgitta; Kjellen, Elisabeth; Mercke, Claes; Alvarez-Fonseca, Mauricio; Billstroem, Anette; Bjoerk-Eriksson, Thomas; Bjoer, Ove; Ekberg, Lars; Friesland, Signe; Karlsson, Magnus; Lagerlund, Magnus; Lundkvist, Lena; Loefroth, Per-Olov; Loefvander-Thapper, Kerstin; Nilsson, Alla; Nyman, Jan; Persson, Essie

    2008-01-01

    Aim: This paper describes the quality assurance (QA) work performed in the Swedish multicenter ARTSCAN (Accelerated RadioTherapy of Squamous cell CArcinomas in the head and Neck) trial to guarantee high quality in a multicenter study which involved modern radiotherapy such as 3DCRT or IMRT. Materials and methods: The study was closed in June 2006 with 750 randomised patients. Radiation therapy-related data for every patient were sent by each participating centre to the QA office where all trial data were reviewed, analysed and stored. In case of any deviation from the protocol, an interactive process was started between the QA office and the local responsible clinician and/or physicist to increase the compliance to the protocol for future randomised patients. Meetings and workshops were held on a regular basis for discussions on various trial-related issues and for the QA office to report on updated results. Results and discussion: This review covers the 734 patients out of a total of 750 who had entered the study. Deviations early in the study were corrected so that the overall compliance to the protocol was very high. There were only negligible variations in doses and dose distributions to target volumes for each specific site and stage. The quality of the treatments was high. Furthermore, an extensive database of treatment parameters was accumulated for future dose-volume vs. endpoint evaluations. Conclusions: This comprehensive QA programme increased the probability to draw firm conclusions from our study and may serve as a concept for QA work in future radiotherapy trials where comparatively small effects are searched for in a heterogeneous tumour population

  6. Size Effect of the 2-D Bodies on the Geothermal Gradient and Q-A Plot

    Science.gov (United States)

    Thakur, M.; Blackwell, D. D.

    2009-12-01

    Using numerical models we have investigated some of the criticisms on the Q-A plot of related to the effect of size of the body on the slope and reduced heat flow. The effects of horizontal conduction depend on the relative difference of radioactivity between the body and the country rock (assuming constant thermal conductivity). Horizontal heat transfer due to different 2-D bodies was numerically studied in order to quantify resulting temperature differences at the Moho and errors on the predication of Qr (reduced heat flow). Using the two end member distributions of radioactivity, the step model (thickness 10km) and exponential model, different 2-D models of horizontal scale (width) ranging from 10 -500 km were investigated. Increasing the horizontal size of the body tends to move observations closer towards the 1-D solution. A temperature difference of 50 oC is produced (for the step model) at Moho between models of width 10 km versus 500 km. In other words the 1-D solution effectively provides large scale averaging in terms of heat flow and temperature field in the lithosphere. For bodies’ ≤ 100 km wide the geotherms at shallower levels are affected, but at depth they converge and are 50 oC lower than that of the infinite plate model temperature. In case of 2-D bodies surface heat flow is decreased due to horizontal transfer of heat, which will shift the Q-A point vertically downward on the Q-A plot. The smaller the size of the body, the more will be the deviation from the 1-D solution and the more will be the movement of Q-A point downwards on a Q-A plot. On the Q-A plot, a limited points of bodies of different sizes with different radioactivity contrast (for the step and exponential model), exactly reproduce the reduced heat flow Qr. Thus the size of the body can affect the slope on a Q-A plot but Qr is not changed. Therefore, Qr ~ 32 mWm-2 obtained from the global terrain average Q-A plot represents the best estimate of stable continental mantle heat

  7. Intensity-modulated radiation therapy: dynamic MLC (DMLC) therapy, multisegment therapy and tomotherapy. An example of QA in DMLC therapy

    International Nuclear Information System (INIS)

    Webb, S.

    1998-01-01

    Intensity-modulated radiation therapy will make a quantum leap in tumor control. It is the new radiation therapy for the new millennium. The major methods to achieve IMRT are: 1. Dynamic multileaf collimator (DMLC) therapy, 2. multisegment therapy, and 3. tomotherapy. The principles of these 3 techniques are briefly reviewed. Each technique presents unique QA issues which are outlined. As an example this paper will present the results of a recent new study of an important QA concern in DMLC therapy. (orig.) [de

  8. Enriching consumer health vocabulary through mining a social Q&A site: A similarity-based approach.

    Science.gov (United States)

    He, Zhe; Chen, Zhiwei; Oh, Sanghee; Hou, Jinghui; Bian, Jiang

    2017-05-01

    The widely known vocabulary gap between health consumers and healthcare professionals hinders information seeking and health dialogue of consumers on end-user health applications. The Open Access and Collaborative Consumer Health Vocabulary (OAC CHV), which contains health-related terms used by lay consumers, has been created to bridge such a gap. Specifically, the OAC CHV facilitates consumers' health information retrieval by enabling consumer-facing health applications to translate between professional language and consumer friendly language. To keep up with the constantly evolving medical knowledge and language use, new terms need to be identified and added to the OAC CHV. User-generated content on social media, including social question and answer (social Q&A) sites, afford us an enormous opportunity in mining consumer health terms. Existing methods of identifying new consumer terms from text typically use ad-hoc lexical syntactic patterns and human review. Our study extends an existing method by extracting n-grams from a social Q&A textual corpus and representing them with a rich set of contextual and syntactic features. Using K-means clustering, our method, simiTerm, was able to identify terms that are both contextually and syntactically similar to the existing OAC CHV terms. We tested our method on social Q&A corpora on two disease domains: diabetes and cancer. Our method outperformed three baseline ranking methods. A post-hoc qualitative evaluation by human experts further validated that our method can effectively identify meaningful new consumer terms on social Q&A. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. TU-G-BRD-06: The Imaging and Radiation Oncology Core Houston (IROC Houston) QA Center International Activities Outside North America

    Energy Technology Data Exchange (ETDEWEB)

    Followill, D; Kry, S; Molineu, A; Lowenstein, J; Alvarez, P; Taylor, P; Nguyen, H; Hernandez, N; Lujano, C; Nguyen, T; Keith, T; Roll, J; Tailor, A [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To describe the extent of IROC Houston’s (formerly the RPC) QA activities and audit results for radiotherapy institutions outside of North America (NA). Methods: The IROC Houston’s QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program provided to international institutions includes: 1) remote TLD/OSLD audit of machine output, 2) credentialing for advanced technologies, and 3) review of patient treatment records. IROC Houston uses the same standards and acceptance criteria for all of its audits whether for North American or international sites. Results: IROC Houston’s QA program has reached out to radiotherapy sites in 43 different countries since 2013 through their participation in clinical trials. In the past two years, 2,778 international megavoltage beam outputs were audited with OSLD/TLD. While the average IROC/Inst ratio is near unity for all sites monitored, there are international regions whose results are significantly different from the NA region. In the past 2 years, 477 and 87 IMRT H&N phantoms were irradiated at NA and international sites, respectively. Regardless of the OSLD beam audit results, the overall pass rate (87 percent) for all international sites (no region separation) is equal to the NA sites. Of the 182 international patient charts reviewed, 10.7 percent of the dose calculation points did not meet our acceptance criterion as compared to 13.6 percent for NA sites. The lower pass rate for NA sites results from a much larger brachytherapy component which has been shown to be more error prone. Conclusion: IROC Houston has expanded its QA services worldwide and continues a long history of improving radiotherapy dose delivery in many countries. Funding received for QA audit services from the Korean GOG, DAHANCA, EORTC, ICON and CMIC

  10. TU-G-BRD-06: The Imaging and Radiation Oncology Core Houston (IROC Houston) QA Center International Activities Outside North America

    International Nuclear Information System (INIS)

    Followill, D; Kry, S; Molineu, A; Lowenstein, J; Alvarez, P; Taylor, P; Nguyen, H; Hernandez, N; Lujano, C; Nguyen, T; Keith, T; Roll, J; Tailor, A

    2015-01-01

    Purpose: To describe the extent of IROC Houston’s (formerly the RPC) QA activities and audit results for radiotherapy institutions outside of North America (NA). Methods: The IROC Houston’s QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program provided to international institutions includes: 1) remote TLD/OSLD audit of machine output, 2) credentialing for advanced technologies, and 3) review of patient treatment records. IROC Houston uses the same standards and acceptance criteria for all of its audits whether for North American or international sites. Results: IROC Houston’s QA program has reached out to radiotherapy sites in 43 different countries since 2013 through their participation in clinical trials. In the past two years, 2,778 international megavoltage beam outputs were audited with OSLD/TLD. While the average IROC/Inst ratio is near unity for all sites monitored, there are international regions whose results are significantly different from the NA region. In the past 2 years, 477 and 87 IMRT H&N phantoms were irradiated at NA and international sites, respectively. Regardless of the OSLD beam audit results, the overall pass rate (87 percent) for all international sites (no region separation) is equal to the NA sites. Of the 182 international patient charts reviewed, 10.7 percent of the dose calculation points did not meet our acceptance criterion as compared to 13.6 percent for NA sites. The lower pass rate for NA sites results from a much larger brachytherapy component which has been shown to be more error prone. Conclusion: IROC Houston has expanded its QA services worldwide and continues a long history of improving radiotherapy dose delivery in many countries. Funding received for QA audit services from the Korean GOG, DAHANCA, EORTC, ICON and CMIC

  11. Quality assurance (QA) and quality control (QC) of image guided radiotherapy (IGRT). Osaka Rosai Hospital experience

    International Nuclear Information System (INIS)

    Tsuboi, Kazuki; Yagi, Masayuki; Fujiwara, Kanta

    2013-01-01

    The linear accelerator with image guided radiation therapy (IGRT) was introduced in May 2010. We performed the verification of the IGRT system, id est (i.e.), acceptance test and our original performance test and confirmed the acceptability for clinical use. We also performed daily QA/QC program before the start of treatment. One-year experience of QA/QC program showed excellent stability of IGRT function compared with our old machine. We further hope to establish the more useful management system and QA/QC program. (author)

  12. QA [Quality Assurance] role in advanced energy activities: Towards an /open quotes/orthodox/close quotes/ Quality Program: Canonizing the traditions at Fermilab

    International Nuclear Information System (INIS)

    Bodnarczuk, M.W.

    1988-02-01

    After a brief description of the goal of Fermi National Accelerator Laboratory (Fermilab) this paper poses and answers three questions related to Quality Assurance (QA) at the Laboratory. First, what is the difference between 'orthodox' and 'unorthodox' QA and is there a place for 'orthodox' QA at a laboratory like Fermilab? Second, are the deeper philosophical and cultural frameworks of high-energy physics acommodating or antagonistic to an 'orthodox' QA Program? Finally, faced with the task of developing an institutional QA program for Fermilab where does one begin? The paper is based on experience with the on-going development and implementation of an institutional QA Program at Fermilab. 10 refs

  13. Basic concept of QA for advanced technologies

    International Nuclear Information System (INIS)

    Mijnheer, Ben

    2008-01-01

    The lecture was structured as follows: (1) Rationale for accurate dose determination; (2) Existing recommendations and guidance; (3) Challenges within the current QA paradigm; (4) New paradigm adopted by AAPM TG 100; and (5) Application of new paradigm to IMRT. Attention was paid, i.a., to major accidents in radiotherapy such as Epinal-1. (P.A.)

  14. Proposal for a Similar Question Search System on a Q&A Site

    Directory of Open Access Journals (Sweden)

    Katsutoshi Kanamori

    2014-06-01

    Full Text Available There is a service to help Internet users obtain answers to specific questions when they visit a Q&A site. A Q&A site is very useful for the Internet user, but posted questions are often not answered immediately. This delay in answering occurs because in most cases another site user is answering the question manually. In this study, we propose a system that can present a question that is similar to a question posted by a user. An advantage of this system is that a user can refer to an answer to a similar question. This research measures the similarity of a candidate question based on word and dependency parsing. In an experiment, we examined the effectiveness of the proposed system for questions actually posted on the Q&A site. The result indicates that the system can show the questioner the answer to a similar question. However, the system still has a number of aspects that should be improved.

  15. SU-G-TeP2-01: Can EPID Based Measurement Replace Traditional Daily Output QA On Megavoltage Linac?

    International Nuclear Information System (INIS)

    Saleh, Z; Tang, X; Song, Y; Obcemea, C; Beeban, N; Chan, M; Li, X; Tang, G; Lim, S; Lovelock, D; LoSasso, T; Mechalakos, J; Both, S

    2016-01-01

    Purpose: To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. Methods: Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since Oct 2014. Daily output measurement for 6/15 MV beams were obtained using SunNuclear DailyQA3 device as part of morning QA. In addition, in-house protocol was implemented for EPID output measurement (10×10 cm fields, 100 MU, 100cm SID, output defined over an ROI of 2×2 cm around central axis). Moreover, the Varian Machine Performance Check (MPC) was used on both machines to measure machine output. The EPID and DailyQA3 based measurements of the relative machine output were compared and cross-correlated with monthly machine output as measured by an A12 Exradin 0.65cc Ion Chamber (IC) serving as ground truth. The results were correlated using Pearson test. Results: The correlations among DailyQA3, in-house EPID and Varian MPC output measurements, with the IC for 6/15 MV were similar for TB1 (0.83–0.95) and TB2 (0.55–0.67). The machine output for the 6/15MV beams on both machines showed a similar trend, namely an increase over time as indicated by all measurements, requiring a machine recalibration after 6 months. This drift is due to a known issue with pressurized monitor chamber which tends to leak over time. MPC failed occasionally but passed when repeated. Conclusion: The results indicate that the use of EPID for daily output measurements has the potential to become a viable and efficient tool for daily routine LINAC QA, thus eliminating weather (T,P) and human setup variability and increasing efficiency of the QA process.

  16. SU-G-TeP2-01: Can EPID Based Measurement Replace Traditional Daily Output QA On Megavoltage Linac?

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Z; Tang, X; Song, Y; Obcemea, C; Beeban, N; Chan, M; Li, X; Tang, G; Lim, S; Lovelock, D; LoSasso, T; Mechalakos, J; Both, S [Memorial Sloan-Kettering Cancer Center, NY (United States)

    2016-06-15

    Purpose: To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. Methods: Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since Oct 2014. Daily output measurement for 6/15 MV beams were obtained using SunNuclear DailyQA3 device as part of morning QA. In addition, in-house protocol was implemented for EPID output measurement (10×10 cm fields, 100 MU, 100cm SID, output defined over an ROI of 2×2 cm around central axis). Moreover, the Varian Machine Performance Check (MPC) was used on both machines to measure machine output. The EPID and DailyQA3 based measurements of the relative machine output were compared and cross-correlated with monthly machine output as measured by an A12 Exradin 0.65cc Ion Chamber (IC) serving as ground truth. The results were correlated using Pearson test. Results: The correlations among DailyQA3, in-house EPID and Varian MPC output measurements, with the IC for 6/15 MV were similar for TB1 (0.83–0.95) and TB2 (0.55–0.67). The machine output for the 6/15MV beams on both machines showed a similar trend, namely an increase over time as indicated by all measurements, requiring a machine recalibration after 6 months. This drift is due to a known issue with pressurized monitor chamber which tends to leak over time. MPC failed occasionally but passed when repeated. Conclusion: The results indicate that the use of EPID for daily output measurements has the potential to become a viable and efficient tool for daily routine LINAC QA, thus eliminating weather (T,P) and human setup variability and increasing efficiency of the QA process.

  17. mosaicQA - A General Approach to Facilitate Basic Data Quality Assurance for Epidemiological Research.

    Science.gov (United States)

    Bialke, Martin; Rau, Henriette; Schwaneberg, Thea; Walk, Rene; Bahls, Thomas; Hoffmann, Wolfgang

    2017-05-29

    Epidemiological studies are based on a considerable amount of personal, medical and socio-economic data. To answer research questions with reliable results, epidemiological research projects face the challenge of providing high quality data. Consequently, gathered data has to be reviewed continuously during the data collection period. This article describes the development of the mosaicQA-library for non-statistical experts consisting of a set of reusable R functions to provide support for a basic data quality assurance for a wide range of application scenarios in epidemiological research. To generate valid quality reports for various scenarios and data sets, a general and flexible development approach was needed. As a first step, a set of quality-related questions, targeting quality aspects on a more general level, was identified. The next step included the design of specific R-scripts to produce proper reports for metric and categorical data. For more flexibility, the third development step focussed on the generalization of the developed R-scripts, e.g. extracting characteristics and parameters. As a last step the generic characteristics of the developed R functionalities and generated reports have been evaluated using different metric and categorical datasets. The developed mosaicQA-library generates basic data quality reports for multivariate input data. If needed, more detailed results for single-variable data, including definition of units, variables, descriptions, code lists and categories of qualified missings, can easily be produced. The mosaicQA-library enables researchers to generate reports for various kinds of metric and categorical data without the need for computational or scripting knowledge. At the moment, the library focusses on the data structure quality and supports the assessment of several quality indicators, including frequency, distribution and plausibility of research variables as well as the occurrence of missing and extreme values. To

  18. From Field Notes to Data Portal - A Scalable Data QA/QC Framework for Tower Networks: Progress and Preliminary Results

    Science.gov (United States)

    Sturtevant, C.; Hackley, S.; Lee, R.; Holling, G.; Bonarrigo, S.

    2017-12-01

    Quality assurance and control (QA/QC) is one of the most important yet challenging aspects of producing research-quality data. Data quality issues are multi-faceted, including sensor malfunctions, unmet theoretical assumptions, and measurement interference from humans or the natural environment. Tower networks such as Ameriflux, ICOS, and NEON continue to grow in size and sophistication, yet tools for robust, efficient, scalable QA/QC have lagged. Quality control remains a largely manual process heavily relying on visual inspection of data. In addition, notes of measurement interference are often recorded on paper without an explicit pathway to data flagging. As such, an increase in network size requires a near-proportional increase in personnel devoted to QA/QC, quickly stressing the human resources available. We present a scalable QA/QC framework in development for NEON that combines the efficiency and standardization of automated checks with the power and flexibility of human review. This framework includes fast-response monitoring of sensor health, a mobile application for electronically recording maintenance activities, traditional point-based automated quality flagging, and continuous monitoring of quality outcomes and longer-term holistic evaluations. This framework maintains the traceability of quality information along the entirety of the data generation pipeline, and explicitly links field reports of measurement interference to quality flagging. Preliminary results show that data quality can be effectively monitored and managed for a multitude of sites with a small group of QA/QC staff. Several components of this framework are open-source, including a R-Shiny application for efficiently monitoring, synthesizing, and investigating data quality issues.

  19. MO-D-213-05: Sensitivity of Routine IMRT QA Metrics to Couch and Collimator Rotations

    International Nuclear Information System (INIS)

    Alaei, P

    2015-01-01

    Purpose: To assess the sensitivity of gamma index and other IMRT QA metrics to couch and collimator rotations. Methods: Two brain IMRT plans with couch and/or collimator rotations in one or more of the fields were evaluated using the IBA MatriXX ion chamber array and its associated software (OmniPro-I’mRT). The plans were subjected to routine QA by 1) Creating a composite planar dose in the treatment planning system (TPS) with the couch/collimator rotations and 2) Creating the planar dose after “zeroing” the rotations. Plan deliveries to MatriXX were performed with all rotations set to zero on a Varian 21ex linear accelerator. This in effect created TPS-created planar doses with an induced rotation error. Point dose measurements for the delivered plans were also performed in a solid water phantom. Results: The IMRT QA of the plans with couch and collimator rotations showed clear discrepancies in the planar dose and 2D dose profile overlays. The gamma analysis, however, did pass with the criteria of 3%/3mm (for 95% of the points), albeit with a lower percentage pass rate, when one or two of the fields had a rotation. Similar results were obtained with tighter criteria of 2%/2mm. Other QA metrics such as percentage difference or distance-to-agreement (DTA) histograms produced similar results. The point dose measurements did not obviously indicate the error due to location of dose measurement (on the central axis) and the size of the ion chamber used (0.6 cc). Conclusion: Relying on Gamma analysis, percentage difference, or DTA to determine the passing of an IMRT QA may miss critical errors in the plan delivery due to couch/collimator rotations. A combination of analyses for composite QA plans, or per-beam analysis, would detect these errors

  20. SU-F-T-558: ArcCheck for Patient Specific QA in Stereotactic Ablative Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ramachandran, P [Peter MacCallum Cancer Centre, Melbourne (Australia); RMIT University, Bundoora (Australia); Tajaldeen, A; Esen, N; Geso, M [RMIT University, Bundoora (Australia); Taylor, D; Wanigaratne, D; Roozen, K; Kron, T [Peter MacCallum Cancer Centre, Melbourne (Australia)

    2016-06-15

    Purpose: Stereotactic Ablative Radiotherapy (SABR) is one of the most preferred treatment techniques for early stage lung cancer. This technique has been extended to other treatment sites like Spine, Liver, Scapula, Sternum etc., This has resulted in increased physics QA time on machine. In this study, we’ve tested the feasibility of using ArcCheck as an alternative method to replace film dosimetry. Methods: Twelve patients with varied diagnosis of Lung, Liver, scapula, sternum and Spine undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients which include ionization chamber and film dosimetry. The required gamma criteria for each SABR plan to pass QA and proceed to treatment is 95% (3%,1mm). In addition to this routine process, the treatment plans were exported on to an ArcCheck phantom. The planned and measured dose from the ArcCheck device were compared using four different gamma criteria: 2%,2 mm, 3%,2 mm, 3%,1 mm and 3%, 3 mm. In addition to this, we’ve also introduced errors to gantry, collimator and couch angle to assess sensitivity of the ArcCheck with potential delivery errors. Results: The ArcCheck mean passing rates for all twelve cases were 76.1%±9.7% for gamma criteria 3%,1 mm, 89.5%±5.3% for 2%,2 mm, 92.6%±4.2% for 3%,2 mm, and 97.6%±2.4% for 3%,3 mm gamma criteria. When SABR spine cases are excluded, we observe ArcCheck passing rates higher than 95% for all the studied cases with 3%, 3mm, and ArcCheck results in acceptable agreement with the film gamma results. Conclusion: Our ArcCheck results at 3%, 3 mm were found to correlate well with our non-SABR spine routine patient specific QA results (3%,1 mm). We observed significant reduction in QA time on using ArcCheck for SABR QA. This study shows that ArcCheck could replace film dosimetry for all sites except SABR spine.

  1. SU-F-T-558: ArcCheck for Patient Specific QA in Stereotactic Ablative Radiotherapy

    International Nuclear Information System (INIS)

    Ramachandran, P; Tajaldeen, A; Esen, N; Geso, M; Taylor, D; Wanigaratne, D; Roozen, K; Kron, T

    2016-01-01

    Purpose: Stereotactic Ablative Radiotherapy (SABR) is one of the most preferred treatment techniques for early stage lung cancer. This technique has been extended to other treatment sites like Spine, Liver, Scapula, Sternum etc., This has resulted in increased physics QA time on machine. In this study, we’ve tested the feasibility of using ArcCheck as an alternative method to replace film dosimetry. Methods: Twelve patients with varied diagnosis of Lung, Liver, scapula, sternum and Spine undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients which include ionization chamber and film dosimetry. The required gamma criteria for each SABR plan to pass QA and proceed to treatment is 95% (3%,1mm). In addition to this routine process, the treatment plans were exported on to an ArcCheck phantom. The planned and measured dose from the ArcCheck device were compared using four different gamma criteria: 2%,2 mm, 3%,2 mm, 3%,1 mm and 3%, 3 mm. In addition to this, we’ve also introduced errors to gantry, collimator and couch angle to assess sensitivity of the ArcCheck with potential delivery errors. Results: The ArcCheck mean passing rates for all twelve cases were 76.1%±9.7% for gamma criteria 3%,1 mm, 89.5%±5.3% for 2%,2 mm, 92.6%±4.2% for 3%,2 mm, and 97.6%±2.4% for 3%,3 mm gamma criteria. When SABR spine cases are excluded, we observe ArcCheck passing rates higher than 95% for all the studied cases with 3%, 3mm, and ArcCheck results in acceptable agreement with the film gamma results. Conclusion: Our ArcCheck results at 3%, 3 mm were found to correlate well with our non-SABR spine routine patient specific QA results (3%,1 mm). We observed significant reduction in QA time on using ArcCheck for SABR QA. This study shows that ArcCheck could replace film dosimetry for all sites except SABR spine.

  2. SU-F-T-227: A Comprehensive Patient Specific, Structure Specific, Pre-Treatment 3D QA Protocol for IMRT, SBRT and VMAT - Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Gueorguiev, G; Cotter, C; Young, M; Toomeh, D [Massachusetts General Hospital Boston MA (United States); University of Massachusetts Lowell Lowell, MA (United States); Khan, F; Crawford, B; Turcotte, J; Sharp, G [Massachusetts General Hospital Boston MA (United States); Mah’D, M [University of Massachusetts Lowell Lowell, MA (United States)

    2016-06-15

    Purpose: To present a 3D QA method and clinical results for 550 patients. Methods: Five hundred and fifty patient treatment deliveries (400 IMRT, 75 SBRT and 75 VMAT) from various treatment sites, planned on Raystation treatment planning system (TPS), were measured on three beam-matched Elekta linear accelerators using IBA’s COMPASS system. The difference between TPS computed and delivered dose was evaluated in 3D by applying three statistical parameters to each structure of interest: absolute average dose difference (AADD, 6% allowed difference), absolute dose difference greater than 6% (ADD6, 4% structure volume allowed to fail) and 3D gamma test (3%/3mm DTA, 4% structure volume allowed to fail). If the allowed value was not met for a given structure, manual review was performed. The review consisted of overlaying dose difference or gamma results with the patient CT, scrolling through the slices. For QA to pass, areas of high dose difference or gamma must be small and not on consecutive slices. For AADD to manually pass QA, the average dose difference in cGy must be less than 50cGy. The QA protocol also includes DVH analysis based on QUANTEC and TG-101 recommended dose constraints. Results: Figures 1–3 show the results for the three parameters per treatment modality. Manual review was performed on 67 deliveries (27 IMRT, 22 SBRT and 18 VMAT), for which all passed QA. Results show that statistical parameter AADD may be overly sensitive for structures receiving low dose, especially for the SBRT deliveries (Fig.1). The TPS computed and measured DVH values were in excellent agreement and with minimum difference. Conclusion: Applying DVH analysis and different statistical parameters to any structure of interest, as part of the 3D QA protocol, provides a comprehensive treatment plan evaluation. Author G. Gueorguiev discloses receiving travel and research funding from IBA for unrelated to this project work. Author B. Crawford discloses receiving travel funding from

  3. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source.

    Science.gov (United States)

    Yang, Y; Sun, L T; Feng, Y C; Fang, X; Lu, W; Zhang, W H; Cao, Y; Zhang, X Z; Zhao, H W

    2014-08-01

    Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

  4. SU-E-J-52: Decreasing Frequency of Performing TG-142 Imaging QA – 5 Year Experience

    International Nuclear Information System (INIS)

    Lin, T; Ma, C

    2015-01-01

    Purpose This study is an update to check if the frequency of imaging QA suggested by AAPM Task Group Report 142 (TG142) is necessary with our 5 year experience. TG142 presents recommendations for QA criteria of IGRT treatment. ACR has adopted it to be the requirements for any radiatiotherapy practices; however, we propose to reduce the frequency on image quality QA according to this 5 year study.Method and Materials: This study uses VarianIX2100 and Siemens Artiste Linacs to perform QAs on KV, MV, CBCT modalities. The QA was designed following under the recommendations of TG142. This study reports the daily imaging positioning/repositioning and imaging and treatment coordinate coincidence. QA results on kV, MV and CBCT from 4/7/2010∼3/11/15 are analyzed. KV, MV, CBCT images are taken with the Varian isocube localized at the isocenter. Digital graticule is used in the software to verify the isocenter position. CBCT images are taken with the cube placed at 1cm superior, lateral and anterior of the isocenter. In-line fusion software is used to verify the contrived shift. Digital ruler provided at the on-board-imaging software or adaptive-targeting software was used to measure the position differences. The position differences were recorded at AP,LR,SI directions. Results 5 year records on kV, MV, CBCT show the shifts in all three directions are within the tolerance of 1mm suggested in TG142 for stereotactic radiation treatment(SRS/SRT). There is no occasion where shifts are outside 1mm tolerance. Conclusions The daily imaging QA suggested in TG142 is useful in ensuring the accuracy needed for SRS/SRT in IGRT. 5 year measurements presented suggest that decreasing the frequency of imaging QA may be acceptable, in particular for institutions reporting no violation of tolerance over periods of few years

  5. SU-E-J-52: Decreasing Frequency of Performing TG-142 Imaging QA – 5 Year Experience

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose This study is an update to check if the frequency of imaging QA suggested by AAPM Task Group Report 142 (TG142) is necessary with our 5 year experience. TG142 presents recommendations for QA criteria of IGRT treatment. ACR has adopted it to be the requirements for any radiatiotherapy practices; however, we propose to reduce the frequency on image quality QA according to this 5 year study.Method and Materials: This study uses VarianIX2100 and Siemens Artiste Linacs to perform QAs on KV, MV, CBCT modalities. The QA was designed following under the recommendations of TG142. This study reports the daily imaging positioning/repositioning and imaging and treatment coordinate coincidence. QA results on kV, MV and CBCT from 4/7/2010∼3/11/15 are analyzed. KV, MV, CBCT images are taken with the Varian isocube localized at the isocenter. Digital graticule is used in the software to verify the isocenter position. CBCT images are taken with the cube placed at 1cm superior, lateral and anterior of the isocenter. In-line fusion software is used to verify the contrived shift. Digital ruler provided at the on-board-imaging software or adaptive-targeting software was used to measure the position differences. The position differences were recorded at AP,LR,SI directions. Results 5 year records on kV, MV, CBCT show the shifts in all three directions are within the tolerance of 1mm suggested in TG142 for stereotactic radiation treatment(SRS/SRT). There is no occasion where shifts are outside 1mm tolerance. Conclusions The daily imaging QA suggested in TG142 is useful in ensuring the accuracy needed for SRS/SRT in IGRT. 5 year measurements presented suggest that decreasing the frequency of imaging QA may be acceptable, in particular for institutions reporting no violation of tolerance over periods of few years.

  6. 40 CFR 98.164 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen in Petroleum Products and... Determination of Carbon, Hydrogen, and Nitrogen in Laboratory Samples of Coal (incorporated by reference, see... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Hydrogen Production § 98.164 Monitoring and QA/QC requirements...

  7. Estimation of eye lens dose during brain scans using Gafchromic XR-QA2 film in various multidetector CT scanners

    International Nuclear Information System (INIS)

    Akhilesh, Philomina; Jamhale, Shramika H.; Sharma, S.D.; Kumar, Rajesh; Datta, D.; Kulkarni, Arti R.

    2017-01-01

    The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. (authors)

  8. SU-F-T-182: A Stochastic Approach to Daily QA Tolerances On Spot Properties for Proton Pencil Beam Scanning

    International Nuclear Information System (INIS)

    St James, S; Bloch, C; Saini, J

    2016-01-01

    Purpose: Proton pencil beam scanning is used clinically across the United States. There are no current guidelines on tolerances for daily QA specific to pencil beam scanning, specifically related to the individual spot properties (spot width). Using a stochastic method to determine tolerances has the potential to optimize tolerances on individual spots and decrease the number of false positive failures in daily QA. Individual and global spot tolerances were evaluated. Methods: As part of daily QA for proton pencil beam scanning, a field of 16 spots (corresponding to 8 energies) is measured using an array of ion chambers (Matrixx, IBA). Each individual spot is fit to two Gaussian functions (x,y). The spot width (σ) in × and y are recorded (32 parameters). Results from the daily QA were retrospectively analyzed for 100 days of data. The deviations of the spot widths were histogrammed and fit to a Gaussian function. The stochastic spot tolerance was taken to be the mean ± 3σ. Using these results, tolerances were developed and tested against known deviations in spot width. Results: The individual spot tolerances derived with the stochastic method decreased in 30/32 instances. Using the previous tolerances (± 20% width), the daily QA would have detected 0/20 days of the deviation. Using a tolerance of any 6 spots failing the stochastic tolerance, 18/20 days of the deviation would have been detected. Conclusion: Using a stochastic method we have been able to decrease daily tolerances on the spot widths for 30/32 spot widths measured. The stochastic tolerances can lead to detection of deviations that previously would have been picked up on monthly QA and missed by daily QA. This method could be easily extended for evaluation of other QA parameters in proton spot scanning.

  9. Improvement in QA protocol for TLD based personnel monitoring laboratory in last five year

    International Nuclear Information System (INIS)

    Rakesh, R.B.

    2018-01-01

    The Quality Assurance (QA) in Personnel monitoring (PM) is a tool to assess the performance of PM laboratories and reliability of dose estimation with respect to standards laid down by international agencies such as IAEA (ISO trumpet curve), IEC, ANSI etc. Reliable personal dose estimation is a basic requirement for radiation protection planning as well as decision making continuous improvement in radiation protection is inherent in radiation protection practices which is highly dependent on accuracy and reliability of the monitoring data. Experience based evolution of Quality control (QC) measures as well as Quality assurance (QA) protocol are two important aspects towards continuous improvement in accuracy and reliability of personnel monitoring results. The paper describes improvement in QC measures and QA protocols initiated during the last five years which led to improvement in the quality of PM services

  10. Conventional patient specific IMRT QA and 3DVH verification of dose distribution for helical tomotherapy

    International Nuclear Information System (INIS)

    Sharma, Prabhat Krishna; Joshi, Kishore; Epili, D.; Gavake, Umesh; Paul, Siji; Reena, Ph.; Jamema, S.V.

    2016-01-01

    In recent years, patient-specific IMRT QA has transitioned from point dose measurements by ion chambers to films to 2D array measurements. 3DVH software has taken this transition a step further by estimating the 3D dose delivered to the patient volume from 2D diode measurements using a planned dose perturbation (PDP) algorithm. This algorithm was developed to determine, if the conventional IMRT QA though sensitive at detecting errors, has any predictive power in detecting dose errors of clinical significance related to dose to the target volume and organs at risk (OAR). The aim of this study is to compare the conventional IMRT patient specific QA and 3DVH dose distribution for patients treated with helical tomotherapy (HT)

  11. 40 CFR 98.414 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Monitoring and QA/QC requirements. 98.414 Section 98.414 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Industrial Greenhouse Gases § 98.414 Monitoring...

  12. 40 CFR 98.214 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Monitoring and QA/QC requirements. 98.214 Section 98.214 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... standard method or other enhanced industry consensus standard method published by an industry consensus...

  13. A community Q&A for HEP Software and Computing ?

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    How often do you use StackOverflow or ServerFault to find information in your daily work? Would you be interested in a community Q&A site for HEP Software and Computing, for instance a dedicated StackExchange site? I looked into this question...

  14. Q&A: Grace Anne Koppel, Living Well with COPD

    Science.gov (United States)

    ... their own lives back is the most rewarding thing we have ever done. Read More "The Challenge of COPD" Articles Q&A: Grace Anne Koppel, Living Well with COPD / What is COPD? / What Causes COPD? / Getting Tested / Am I at Risk? / COPD Quiz Fall ...

  15. The GSPC: Newest Franchise in al-Qa'ida's Global Jihad

    National Research Council Canada - National Science Library

    Boudali, Lianne K

    2007-01-01

    .... Some observers have speculated that North Africa may be the next safe haven for al Qa ida, and that European countries may face a greater risk of attack if Algerian terrorist groups expand their base...

  16. MO-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA I

    International Nuclear Information System (INIS)

    Clements, M; Wiesmeyer, M

    2014-01-01

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Automated Imaging QA for TG-142 with RIT Presentation Time: 2:45 – 3:15 PM This presentation will discuss software tools for automated imaging QA and phantom analysis for TG-142. All modalities used in radiation oncology will be discussed, including CBCT, planar kV imaging, planar MV imaging, and imaging and treatment coordinate coincidence. Vendor supplied phantoms as well as a variety of third-party phantoms will be shown, along with appropriate analyses, proper phantom setup procedures and scanning settings, and a discussion of image quality metrics. Tools for process automation will be discussed which include: RIT Cognition (machine learning for phantom image identification), RIT Cerberus (automated file system monitoring and searching), and RunQueueC (batch processing of multiple images). In addition to phantom analysis, tools for statistical tracking, trending, and reporting will be discussed. This discussion will include an introduction to statistical process control, a valuable tool in analyzing data and determining appropriate tolerances. An Introduction to TG-142 Imaging QA Using Standard Imaging Products Presentation Time: 3:15 – 3:45 PM Medical Physicists want to understand the logic behind TG-142 Imaging QA. What is often missing is a firm understanding of the connections between the EPID and OBI phantom imaging, the software “algorithms” that calculate the QA metrics, the establishment of baselines, and the analysis and interpretation of the results. The goal of our brief presentation will be to

  17. MO-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA I

    Energy Technology Data Exchange (ETDEWEB)

    Clements, M [RAD Image, Colorado Springs, CO (United States); Wiesmeyer, M [Standard Imaging, Inc., Middleton, WI (United States)

    2014-06-15

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Automated Imaging QA for TG-142 with RIT Presentation Time: 2:45 – 3:15 PM This presentation will discuss software tools for automated imaging QA and phantom analysis for TG-142. All modalities used in radiation oncology will be discussed, including CBCT, planar kV imaging, planar MV imaging, and imaging and treatment coordinate coincidence. Vendor supplied phantoms as well as a variety of third-party phantoms will be shown, along with appropriate analyses, proper phantom setup procedures and scanning settings, and a discussion of image quality metrics. Tools for process automation will be discussed which include: RIT Cognition (machine learning for phantom image identification), RIT Cerberus (automated file system monitoring and searching), and RunQueueC (batch processing of multiple images). In addition to phantom analysis, tools for statistical tracking, trending, and reporting will be discussed. This discussion will include an introduction to statistical process control, a valuable tool in analyzing data and determining appropriate tolerances. An Introduction to TG-142 Imaging QA Using Standard Imaging Products Presentation Time: 3:15 – 3:45 PM Medical Physicists want to understand the logic behind TG-142 Imaging QA. What is often missing is a firm understanding of the connections between the EPID and OBI phantom imaging, the software “algorithms” that calculate the QA metrics, the establishment of baselines, and the analysis and interpretation of the results. The goal of our brief presentation will be to

  18. 40 CFR 98.394 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Monitoring and QA/QC requirements. 98... by a consensus-based standards organization exists, such a method shall be used. Consensus-based... (NAESB). (ii) Where no appropriate standard method developed by a consensus-based standards organization...

  19. 40 CFR 98.424 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Monitoring and QA/QC requirements. 98... published by a consensus-based standards organization if such a method exists. Consensus-based standards...). (ii) Where no appropriate standard method developed by a consensus-based standards organization exists...

  20. Experience in the application of the IAEA QA code and guides to the manufacture of nuclear reactor components

    International Nuclear Information System (INIS)

    Dutta, N.G.; Mankame, M.A.; Kulkarni, P.G.; Vijayaraghavan, R.; Balaramamoorthy, K.

    1985-01-01

    India has made considerable progress in the indigenous manufacture of 'Quality' nuclear reactor components. All activities associated with the development of atomic energy from mining of strategic minerals to the design, construction, and operation of nuclear power plants including supporting research and development efforts are mainly carried out by the Department of Atomic Energy (DAE). Through the sustained efforts of DAE, the major industries, both in public and private sectors supplying nuclear components have now adopted the practice of systematic quality assurance (QA). The stringent QA steps are mandatory for achieving the desired quality in the manufactured nuclear components. Control blades for BWRs are now indigenously manufactured by the Atomic Fuels Division (AFD) of Bhabha Atomic Research Centre (BARC), a constituent unit of DAE. For the Project Dhruva, a 100 MW(th) nuclear reactor, constructed at BARC, Trombay, Bombay, an independent cell was formed to carry out quality audit on the manufactured components. The components were designed, fabricated, inspected and tested to the desired quality level. The QA activities were enforced from the procurement of raw materials to the audit of the completed component for monitoring the manufacturer's continued compliance with the design. The major components of Dhruva, viz. calandria, end-shield, coolant channels, heat exchangers, etc., were covered under these quality audit activities. The paper highlights the QA programme implemented in the manufacture of control blades for BWRs, illustrated with a typical example, the end-shield for Dhruva. The authors consider that the recommendations and guidelines provided in the documents 50-SG-QA3, 50-SG-QA8, 50-SG-QA10, etc., were useful in providing a formal and systematic framework, under which various quality assurance functions have been carried out

  1. Characterization of a prototype MR-compatible Delta4 QA-system in a 1.5 tesla MR-linac

    NARCIS (Netherlands)

    de Vries, Wilfred J H; Seravalli, Enrica; Houweling, Anette; Woodings, Simon J; van Rooij, Rob; Wolthaus, Jochem W H; Lagendijk, JJW; Raaymakers, Bas W

    2018-01-01

    To perform patient plan-quality assurance (QA) on the newly installed MR-Linac (MRL) there was a need for having an MR-compatible QA-device. An MR compatible device (MR-Delta4) was developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response

  2. SU-F-T-459: ArcCHECK Machine QA : Highly Efficient Quality Assurance Tool for VMAT, SRS & SBRT Linear Accelerator Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Mhatre, V; Patwe, P; Dandekar, P [Sir HN RF Hospital, Mumbai, Maharashtra (India)

    2016-06-15

    Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. ArcCHECK Machine QA tool is used to test geometric and delivery aspects of linear accelerator. In this study we evaluated the performance of this tool. Methods: Machine QA feature allows user to perform quality assurance tests using ArcCHECK phantom. Following tests were performed 1) Gantry Speed 2) Gantry Rotation 3) Gantry Angle 4)MLC/Collimator QA 5)Beam Profile Flatness & Symmetry. Data was collected on trueBEAM stX machine for 6 MV for a period of one year. The Gantry QA test allows to view errors in gantry angle, rotation & assess how accurately the gantry moves around the isocentre. The MLC/Collimator QA tool is used to analyze & locate the differences between leaf bank & jaw position of linac. The flatness & Symmetry test quantifies beam flatness & symmetry in IEC-y & x direction. The Gantry & Flatness/Symmetry test can be performed for static & dynamic delivery. Results: The Gantry speed was 3.9 deg/sec with speed maximum deviation around 0.3 deg/sec. The Gantry Isocentre for arc delivery was 0.9mm & static delivery was 0.4mm. The maximum percent positive & negative difference was found to be 1.9 % & – 0.25 % & maximum distance positive & negative diff was 0.4mm & – 0.3 mm for MLC/Collimator QA. The Flatness for Arc delivery was 1.8 % & Symmetry for Y was 0.8 % & X was 1.8 %. The Flatness for gantry 0°,270°,90° & 180° was 1.75,1.9,1.8 & 1.6% respectively & Symmetry for X & Y was 0.8,0.6% for 0°, 0.6,0.7% for 270°, 0.6,1% for 90° & 0.6,0.7% for 180°. Conclusion: ArcCHECK Machine QA is an useful tool for QA of Modern linear accelerators as it tests both geometric & delivery aspects. This is very important for VMAT, SRS & SBRT treatments.

  3. SU-F-T-459: ArcCHECK Machine QA : Highly Efficient Quality Assurance Tool for VMAT, SRS & SBRT Linear Accelerator Delivery

    International Nuclear Information System (INIS)

    Mhatre, V; Patwe, P; Dandekar, P

    2016-01-01

    Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. ArcCHECK Machine QA tool is used to test geometric and delivery aspects of linear accelerator. In this study we evaluated the performance of this tool. Methods: Machine QA feature allows user to perform quality assurance tests using ArcCHECK phantom. Following tests were performed 1) Gantry Speed 2) Gantry Rotation 3) Gantry Angle 4)MLC/Collimator QA 5)Beam Profile Flatness & Symmetry. Data was collected on trueBEAM stX machine for 6 MV for a period of one year. The Gantry QA test allows to view errors in gantry angle, rotation & assess how accurately the gantry moves around the isocentre. The MLC/Collimator QA tool is used to analyze & locate the differences between leaf bank & jaw position of linac. The flatness & Symmetry test quantifies beam flatness & symmetry in IEC-y & x direction. The Gantry & Flatness/Symmetry test can be performed for static & dynamic delivery. Results: The Gantry speed was 3.9 deg/sec with speed maximum deviation around 0.3 deg/sec. The Gantry Isocentre for arc delivery was 0.9mm & static delivery was 0.4mm. The maximum percent positive & negative difference was found to be 1.9 % & – 0.25 % & maximum distance positive & negative diff was 0.4mm & – 0.3 mm for MLC/Collimator QA. The Flatness for Arc delivery was 1.8 % & Symmetry for Y was 0.8 % & X was 1.8 %. The Flatness for gantry 0°,270°,90° & 180° was 1.75,1.9,1.8 & 1.6% respectively & Symmetry for X & Y was 0.8,0.6% for 0°, 0.6,0.7% for 270°, 0.6,1% for 90° & 0.6,0.7% for 180°. Conclusion: ArcCHECK Machine QA is an useful tool for QA of Modern linear accelerators as it tests both geometric & delivery aspects. This is very important for VMAT, SRS & SBRT treatments.

  4. DeepQA: Improving the estimation of single protein model quality with deep belief networks

    OpenAIRE

    Cao, Renzhi; Bhattacharya, Debswapna; Hou, Jie; Cheng, Jianlin

    2016-01-01

    Background Protein quality assessment (QA) useful for ranking and selecting protein models has long been viewed as one of the major challenges for protein tertiary structure prediction. Especially, estimating the quality of a single protein model, which is important for selecting a few good models out of a large model pool consisting of mostly low-quality models, is still a largely unsolved problem. Results We introduce a novel single-model quality assessment method DeepQA based on deep belie...

  5. The assessment report of QA program through the analysis of quality trend in 1994

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yung Se; Hong, Kyung Sik; Park, Sang Pil; Park, Kun Woo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    Effectiveness and adequacy of KAERI Qualify Assurance Program is assessed through the analysis of quality trend. As a result of assessment, Quality Assurance System for each project has reached the stage of stabilization, and especially, significant improvement of the conformance to QA procedure, the control of QA Records and documents and the inspiration of quality mind for the job has been made. However, some problems discovered in this trend analysis, ie, improvement of efficiency of quality training and economies of design verification system, are required to take preventive actions and consider appropriate measures. In the future, QA is expected to be a support to assurance of nuclear safety and development of advanced technology by making it possible to establish the best quality system suitable for our situation, based on the assessment method for quality assurance program presented in this study. 5 figs., 30 tabs. (Author).

  6. The assessment report of QA program through the analysis of quality trend in 1994

    International Nuclear Information System (INIS)

    Kim, Yung Se; Hong, Kyung Sik; Park, Sang Pil; Park, Kun Woo

    1995-04-01

    Effectiveness and adequacy of KAERI Qualify Assurance Program is assessed through the analysis of quality trend. As a result of assessment, Quality Assurance System for each project has reached the stage of stabilization, and especially, significant improvement of the conformance to QA procedure, the control of QA Records and documents and the inspiration of quality mind for the job has been made. However, some problems discovered in this trend analysis, ie, improvement of efficiency of quality training and economies of design verification system, are required to take preventive actions and consider appropriate measures. In the future, QA is expected to be a support to assurance of nuclear safety and development of advanced technology by making it possible to establish the best quality system suitable for our situation, based on the assessment method for quality assurance program presented in this study. 5 figs., 30 tabs. (Author)

  7. SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, T; Sun, B; Grantham, K; Knutson, N; Santanam, L; Goddu, S; Klein, E [Washington University, St. Louis, MO (United States)

    2014-06-01

    Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA.

  8. SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

    International Nuclear Information System (INIS)

    Zhao, T; Sun, B; Grantham, K; Knutson, N; Santanam, L; Goddu, S; Klein, E

    2014-01-01

    Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA

  9. 40 CFR 98.144 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Monitoring and QA/QC requirements. 98... fraction for each carbonate consumed based on sampling and chemical analysis using an industry consensus... testing method published by an industry consensus standards organization (e.g., ASTM, ASME, API, etc.). ...

  10. 40 CFR 98.404 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Monitoring and QA/QC requirements. 98... published by a consensus-based standards organization exists, such a method shall be used. Consensus-based... (NAESB). (ii) Where no appropriate standard method developed by a consensus-based standards organization...

  11. QA engineering for the LCP USA magnet manufacturers

    International Nuclear Information System (INIS)

    Childress, C.E.; Batey, J.E.; Burn, P.B.

    1981-01-01

    This paper describes the QA and QC efforts and results used in fabricating the superconducting magnets of competing designs being developed by American Manufacturers for testing in the ORNL Large Coil Test Facility. Control of the design, materials and processes to assure proper functioning of the magnets in the test facility as well as the content of archival data being compiled is discussed

  12. SU-E-T-29: A Web Application for GPU-Based Monte Carlo IMRT/VMAT QA with Delivered Dose Verification

    International Nuclear Information System (INIS)

    Folkerts, M; Graves, Y; Tian, Z; Gu, X; Jia, X; Jiang, S

    2014-01-01

    Purpose: To enable an existing web application for GPU-based Monte Carlo (MC) 3D dosimetry quality assurance (QA) to compute “delivered dose” from linac logfile data. Methods: We added significant features to an IMRT/VMAT QA web application which is based on existing technologies (HTML5, Python, and Django). This tool interfaces with python, c-code libraries, and command line-based GPU applications to perform a MC-based IMRT/VMAT QA. The web app automates many complicated aspects of interfacing clinical DICOM and logfile data with cutting-edge GPU software to run a MC dose calculation. The resultant web app is powerful, easy to use, and is able to re-compute both plan dose (from DICOM data) and delivered dose (from logfile data). Both dynalog and trajectorylog file formats are supported. Users upload zipped DICOM RP, CT, and RD data and set the expected statistic uncertainty for the MC dose calculation. A 3D gamma index map, 3D dose distribution, gamma histogram, dosimetric statistics, and DVH curves are displayed to the user. Additional the user may upload the delivery logfile data from the linac to compute a 'delivered dose' calculation and corresponding gamma tests. A comprehensive PDF QA report summarizing the results can also be downloaded. Results: We successfully improved a web app for a GPU-based QA tool that consists of logfile parcing, fluence map generation, CT image processing, GPU based MC dose calculation, gamma index calculation, and DVH calculation. The result is an IMRT and VMAT QA tool that conducts an independent dose calculation for a given treatment plan and delivery log file. The system takes both DICOM data and logfile data to compute plan dose and delivered dose respectively. Conclusion: We sucessfully improved a GPU-based MC QA tool to allow for logfile dose calculation. The high efficiency and accessibility will greatly facilitate IMRT and VMAT QA

  13. SU-E-T-29: A Web Application for GPU-Based Monte Carlo IMRT/VMAT QA with Delivered Dose Verification

    Energy Technology Data Exchange (ETDEWEB)

    Folkerts, M [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States); University of California, San Diego, La Jolla, CA (United States); Graves, Y [University of California, San Diego, La Jolla, CA (United States); Tian, Z; Gu, X; Jia, X; Jiang, S [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States)

    2014-06-01

    Purpose: To enable an existing web application for GPU-based Monte Carlo (MC) 3D dosimetry quality assurance (QA) to compute “delivered dose” from linac logfile data. Methods: We added significant features to an IMRT/VMAT QA web application which is based on existing technologies (HTML5, Python, and Django). This tool interfaces with python, c-code libraries, and command line-based GPU applications to perform a MC-based IMRT/VMAT QA. The web app automates many complicated aspects of interfacing clinical DICOM and logfile data with cutting-edge GPU software to run a MC dose calculation. The resultant web app is powerful, easy to use, and is able to re-compute both plan dose (from DICOM data) and delivered dose (from logfile data). Both dynalog and trajectorylog file formats are supported. Users upload zipped DICOM RP, CT, and RD data and set the expected statistic uncertainty for the MC dose calculation. A 3D gamma index map, 3D dose distribution, gamma histogram, dosimetric statistics, and DVH curves are displayed to the user. Additional the user may upload the delivery logfile data from the linac to compute a 'delivered dose' calculation and corresponding gamma tests. A comprehensive PDF QA report summarizing the results can also be downloaded. Results: We successfully improved a web app for a GPU-based QA tool that consists of logfile parcing, fluence map generation, CT image processing, GPU based MC dose calculation, gamma index calculation, and DVH calculation. The result is an IMRT and VMAT QA tool that conducts an independent dose calculation for a given treatment plan and delivery log file. The system takes both DICOM data and logfile data to compute plan dose and delivered dose respectively. Conclusion: We sucessfully improved a GPU-based MC QA tool to allow for logfile dose calculation. The high efficiency and accessibility will greatly facilitate IMRT and VMAT QA.

  14. SU-F-T-489: 4-Years Experience of QA in TomoTherapy MVCT: What Do We Look Out For?

    Energy Technology Data Exchange (ETDEWEB)

    Lee, F; Chan, K [Queen Elizabeth Hospital, Hong Kong (Hong Kong)

    2016-06-15

    Purpose: To evaluate the QA results of TomoTherapy MVCT from March 2012 to February 2016, and to identify issues that may affect consistency in HU numbers and reconstructed treatment dose in MVCT. Methods: Monthly QA was performed on our TomoHD system. Phantom with rod inserts of various mass densities was imaged in MVCT and compared to baseline to evaluate HU number consistency. To evaluate treatment dose reconstructed by delivered sinogram and MVCT, a treatment plan was designed on a humanoid skull phantom. The phantom was imaged with MVCT and treatment plan was delivered to obtain the sinogram. The dose reconstructed with the Planned Adaptive software was compared to the dose in the original plan. The QA tolerance for HU numbers was ±30 HU, and ±2% for discrepancy between original plan dose and reconstructed dose. Tolerances were referenced to AAPM TG148. Results: Several technical modifications or maintenance activities to the system have been identified which affected QA Results: 1) Upgrade in console system software which added a weekly HU calibration procedure; 2) Linac or MLC replacement leading to change in Accelerator Output Machine (AOM) parameters; 3) Upgrade in planning system algorithm affecting MVCT dose reconstruction. These events caused abrupt changes in QA results especially for the reconstructed dose. In the past 9 months, when no such modifications were done to the system, reconstructed dose was consistent with maximum deviation from baseline less than 0.6%. The HU number deviated less than 5HU. Conclusion: Routine QA is essential for MVCT, especially if the MVCT is used for daily dose reconstruction to monitor delivered dose to patients. Several technical events which may affect consistency of this are software changes, linac or MLC replacement. QA results reflected changes which justify re-calibration or system adjustment. In normal circumstances, the system should be relatively stable and quarterly QA may be sufficient.

  15. The Second Round of the PHAR-QA Survey of Competences for Pharmacy Practice

    Directory of Open Access Journals (Sweden)

    Jeffrey Atkinson

    2016-09-01

    Full Text Available This paper presents the results of the second European Delphi round on the ranking of competences for pharmacy practice and compares these data to those of the first round already published. A comparison of the numbers of respondents, distribution by age group, country of residence, etc., shows that whilst the student population of respondents changed from Round 1 to 2, the populations of the professional groups (community, hospital and industrial pharmacists, pharmacists in other occupations and academics were more stable. Results are given for the consensus of ranking and the scores of ranking of 50 competences for pharmacy practice. This two-stage, large-scale Delphi process harmonized and validated the Quality Assurance in European Pharmacy Education and Training (PHAR-QA framework and ensured the adoption by the pharmacy profession of a framework proposed by the academic pharmacy community. The process of evaluation and validation of ranking of competences by the pharmacy profession is now complete, and the PHAR-QA consortium will now put forward a definitive PHAR-QA framework of competences for pharmacy practice.

  16. The Second Round of the PHAR-QA Survey of Competences for Pharmacy Practice

    Science.gov (United States)

    Atkinson, Jeffrey; De Paepe, Kristien; Pozo, Antonio Sánchez; Rekkas, Dimitrios; Volmer, Daisy; Hirvonen, Jouni; Bozic, Borut; Skowron, Agnieska; Mircioiu, Constantin; Marcincal, Annie; Koster, Andries; Wilson, Keith; van Schravendijk, Chris

    2016-01-01

    This paper presents the results of the second European Delphi round on the ranking of competences for pharmacy practice and compares these data to those of the first round already published. A comparison of the numbers of respondents, distribution by age group, country of residence, etc., shows that whilst the student population of respondents changed from Round 1 to 2, the populations of the professional groups (community, hospital and industrial pharmacists, pharmacists in other occupations and academics) were more stable. Results are given for the consensus of ranking and the scores of ranking of 50 competences for pharmacy practice. This two-stage, large-scale Delphi process harmonized and validated the Quality Assurance in European Pharmacy Education and Training (PHAR-QA) framework and ensured the adoption by the pharmacy profession of a framework proposed by the academic pharmacy community. The process of evaluation and validation of ranking of competences by the pharmacy profession is now complete, and the PHAR-QA consortium will now put forward a definitive PHAR-QA framework of competences for pharmacy practice. PMID:28970400

  17. QA role in advanced energy activities: Reductionism, emergence, and functionalism; presuppositions in designing internal QA audits

    Energy Technology Data Exchange (ETDEWEB)

    Bodnarczuk, M.

    1988-06-01

    After a brief overview of the mission of Fermilab, this paper explores some of the problems associated with designing internal QA audits. The paper begins with several examples of how audits should not be designed, then goes on to analyze two types of presuppositions about organizational structure (reductionism and emergence) that can be misleading and skew the data sample if folded too heavily into the checklist. A third type of presupposition (functionalism), is proposed as a viable way of achieving a more well-rounded measure of the performance of an organization, i.e. its effectiveness, not just compliance.

  18. Monte Carlo generated spectra for QA/QC of automated NAA routine

    International Nuclear Information System (INIS)

    Jackman, K.R.; Biegalski, S.R.

    2007-01-01

    A quality check for an automated system of analyzing large sets of neutron activated samples has been developed. Activated samples are counted with an HPGe detector, in conjunction with an automated sample changer and spectral analysis tools, controlled by the Canberra GENIE 2K and REXX software. After each sample is acquired and analyzed, a Microsoft Visual Basic program imports the results into a template Microsoft Excel file where the final concentrations, uncertainties, and detection limits are determined. Standard reference materials are included in each set of 40 samples as a standard quality assurance/quality control (QA/QC) test. A select group of sample spectra are also visually reviewed to check the peak fitting routines. A reference spectrum was generated in MCNP 4c2 using an F8, pulse-height, tally with a detector model of the actual detector used in counting. The detector model matches the detector resolution, energy calibration, and counting geometry. The generated spectrum also contained a radioisotope matrix that was similar to what was expected in the samples. This spectrum can then be put through the automated system and analyzed along with the other samples. The automated results are then compared to expected results for QA/QC assurance. (author)

  19. Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA.

    Science.gov (United States)

    Hillman, Yair; Kim, Josh; Chetty, Indrin; Wen, Ning

    2018-04-01

    Mobius 3D (M3D) provides a volumetric dose verification of the treatment planning system's calculated dose using an independent beam model and a collapsed cone convolution superposition algorithm. However, there is a lack of investigation into M3D's accuracy and effectiveness for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) quality assurance (QA). Here, we collaborated with the vendor to develop a revised M3D beam model for SRS/SBRT cases treated with a 6X flattening filter-free (FFF) beam and high-definition multiple leaf collimator (HDMLC) on an Edge linear accelerator. Eighty SRS/SBRT cases, planned with AAA dose algorithm and validated with Gafchromic film, were compared to M3D dose calculations using 3D gamma analysis with 2%/2 mm gamma criteria and a 10% threshold. A revised beam model was developed by refining the HD-MLC model in M3D to improve small field dose calculation accuracy and beam profile agreement. All cases were reanalyzed using the revised beam model. The impact of heterogeneity corrections for lung cases was investigated by applying lung density overrides to five cases. For the standard and revised beam models, respectively, the mean gamma passing rates were 94.6% [standard deviation (SD): 6.1%] and 98.0% [SD: 1.7%] (for the overall patient), 88.2% [SD: 17.3%] and 93.8% [SD: 6.8%] (for the brain PTV), 71.4% [SD: 18.4%] and 81.5% [SD: 14.3%] (for the lung PTV), 83.3% [SD: 16.7%] and 67.9% [SD: 23.0%] (for the spine PTV), and 78.6% [SD: 14.0%] and 86.8% [SD: 12.5%] (for the PTV of all other sites). The lung PTV mean gamma passing rates improved from 74.1% [SD: 7.5%] to 89.3% [SD: 7.2%] with the lung density overridden. The revised beam model achieved an output factor within 3% of plastic scintillator measurements for 2 × 2 cm 2 MLC field size, but larger discrepancies are still seen for smaller field sizes which necessitate further improvement of the beam model. Special attention needs to be paid to small field

  20. Q&A: The Basics of California's School Finance System

    Science.gov (United States)

    EdSource, 2006

    2006-01-01

    In a state as large and complex as California, education financing can become as complicated as rocket science. This two-page Q&A provides a brief, easy-to-understand explanation of California's school finance system and introduces the issues of its adequacy and equity. A list of resources providing additional information is provided.

  1. 40 CFR 98.174 - Monitoring and QA/QC requirements.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Iron and Steel Production § 98.174 Monitoring and QA/QC... moisture content of the stack gas. (5) Determine the mass rate of process feed or process production (as... Fusion Techniques (incorporated by reference, see § 98.7) for iron and ferrous scrap. (v) ASM CS-104 UNS...

  2. A novel DTI-QA tool: Automated metric extraction exploiting the sphericity of an agar filled phantom.

    Science.gov (United States)

    Chavez, Sofia; Viviano, Joseph; Zamyadi, Mojdeh; Kingsley, Peter B; Kochunov, Peter; Strother, Stephen; Voineskos, Aristotle

    2018-02-01

    To develop a quality assurance (QA) tool (acquisition guidelines and automated processing) for diffusion tensor imaging (DTI) data using a common agar-based phantom used for fMRI QA. The goal is to produce a comprehensive set of automated, sensitive and robust QA metrics. A readily available agar phantom was scanned with and without parallel imaging reconstruction. Other scanning parameters were matched to the human scans. A central slab made up of either a thick slice or an average of a few slices, was extracted and all processing was performed on that image. The proposed QA relies on the creation of two ROIs for processing: (i) a preset central circular region of interest (ccROI) and (ii) a signal mask for all images in the dataset. The ccROI enables computation of average signal for SNR calculations as well as average FA values. The production of the signal masks enables automated measurements of eddy current and B0 inhomogeneity induced distortions by exploiting the sphericity of the phantom. Also, the signal masks allow automated background localization to assess levels of Nyquist ghosting. The proposed DTI-QA was shown to produce eleven metrics which are robust yet sensitive to image quality changes within site and differences across sites. It can be performed in a reasonable amount of scan time (~15min) and the code for automated processing has been made publicly available. A novel DTI-QA tool has been proposed. It has been applied successfully on data from several scanners/platforms. The novelty lies in the exploitation of the sphericity of the phantom for distortion measurements. Other novel contributions are: the computation of an SNR value per gradient direction for the diffusion weighted images (DWIs) and an SNR value per non-DWI, an automated background detection for the Nyquist ghosting measurement and an error metric reflecting the contribution of EPI instability to the eddy current induced shape changes observed for DWIs. Copyright © 2017 Elsevier

  3. QA practice for online analyzers in water steam cycles

    International Nuclear Information System (INIS)

    Staub, L.

    2010-01-01

    The liberalization of power markets throughout the world has resulted in more and more power stations being operated in cycling mode, with frequent load changes and multiple daily start-up and shut-down cycles. This more flexible operation also calls for better automation and poses new challenges to water chemistry in water steam cycles, to avoid subsequent damage to vital plant components such as turbines, boilers or condensers. But automation for the most important chemistry control tool, the sampling and online analyzer system, is only possible if chemists can rely on their online analysis equipment. Proof of plausibility as well as reliability and availability of online analysis results becomes a major focus. While SOP and standard QA procedures for laboratory equipment are well established and daily practice, such measures are widely neglected for online process analyzers. This paper is aiming to establish a roadmap for the implementation of SOP and QA/QC procedures for online instruments in water steam cycles, leading to reliable chemical information that is trustworthy for process automation and chemistry control in water steam cycles. (author)

  4. QA practice for online analyzers in water steam cycles

    International Nuclear Information System (INIS)

    Staub Lukas

    2009-01-01

    The liberalization of power markets throughout the world has resulted in more and more power stations being operated in cycling mode, with frequent load changes and multiple daily start-up and shut-down cycles. This more flexible operation also calls for better automation and poses new challenges to water chemistry in water steam cycles, to avoid subsequent damage to vital plant components such as turbines, boilers or condensers. But automation for the most important chemistry control tool, the sampling and online analyzer system, is only possible if chemists can rely on their online analysis equipment. Proof of plausibility as well as reliability and availability of online analysis results becomes a major focus. While SOP and standard QA procedures for laboratory equipment are well established and daily practice, such measures are widely neglected for online process analyzers. This paper is aiming to establish a roadmap for the implementation of SOP and QA/QC procedures for online instruments in water steam cycles, leading to reliable chemical information that is trustworthy for process automation and chemistry control in water steam cycles. (author)

  5. SU-F-P-07: Applying Failure Modes and Effects Analysis to Treatment Planning System QA

    International Nuclear Information System (INIS)

    Mathew, D; Alaei, P

    2016-01-01

    Purpose: A small-scale implementation of Failure Modes and Effects Analysis (FMEA) for treatment planning system QA by utilizing methodology of AAPM TG-100 report. Methods: FMEA requires numerical values for severity (S), occurrence (O) and detectability (D) of each mode of failure. The product of these three values gives a risk priority number (RPN). We have implemented FMEA for the treatment planning system (TPS) QA for two clinics which use Pinnacle and Eclipse TPS. Quantitative monthly QA data dating back to 4 years for Pinnacle and 1 year for Eclipse have been used to determine values for severity (deviations from predetermined doses at points or volumes), and occurrence of such deviations. The TPS QA protocol includes a phantom containing solid water and lung- and bone-equivalent heterogeneities. Photon and electron plans have been evaluated in both systems. The dose values at multiple distinct points of interest (POI) within the solid water, lung, and bone-equivalent slabs, as well as mean doses to several volumes of interest (VOI), have been re-calculated monthly using the available algorithms. Results: The computed doses vary slightly month-over-month. There have been more significant deviations following software upgrades, especially if the upgrade involved re-modeling of the beams. TG-100 guidance and the data presented here suggest an occurrence (O) of 2 depending on the frequency of re-commissioning the beams, severity (S) of 3, and detectability (D) of 2, giving an RPN of 12. Conclusion: Computerized treatment planning systems could pose a risk due to dosimetric errors and suboptimal treatment plans. The FMEA analysis presented here suggests that TPS QA should immediately follow software upgrades, but does not need to be performed every month.

  6. SU-F-P-07: Applying Failure Modes and Effects Analysis to Treatment Planning System QA

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, D; Alaei, P [University Minnesota, Minneapolis, MN (United States)

    2016-06-15

    Purpose: A small-scale implementation of Failure Modes and Effects Analysis (FMEA) for treatment planning system QA by utilizing methodology of AAPM TG-100 report. Methods: FMEA requires numerical values for severity (S), occurrence (O) and detectability (D) of each mode of failure. The product of these three values gives a risk priority number (RPN). We have implemented FMEA for the treatment planning system (TPS) QA for two clinics which use Pinnacle and Eclipse TPS. Quantitative monthly QA data dating back to 4 years for Pinnacle and 1 year for Eclipse have been used to determine values for severity (deviations from predetermined doses at points or volumes), and occurrence of such deviations. The TPS QA protocol includes a phantom containing solid water and lung- and bone-equivalent heterogeneities. Photon and electron plans have been evaluated in both systems. The dose values at multiple distinct points of interest (POI) within the solid water, lung, and bone-equivalent slabs, as well as mean doses to several volumes of interest (VOI), have been re-calculated monthly using the available algorithms. Results: The computed doses vary slightly month-over-month. There have been more significant deviations following software upgrades, especially if the upgrade involved re-modeling of the beams. TG-100 guidance and the data presented here suggest an occurrence (O) of 2 depending on the frequency of re-commissioning the beams, severity (S) of 3, and detectability (D) of 2, giving an RPN of 12. Conclusion: Computerized treatment planning systems could pose a risk due to dosimetric errors and suboptimal treatment plans. The FMEA analysis presented here suggests that TPS QA should immediately follow software upgrades, but does not need to be performed every month.

  7. SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

    International Nuclear Information System (INIS)

    Wahi-Anwar, M; Lo, P; Kim, H; Brown, M; McNitt-Gray, M

    2016-01-01

    Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifies the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel

  8. SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Wahi-Anwar, M; Lo, P; Kim, H; Brown, M; McNitt-Gray, M [UCLA Radiological Sciences, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifies the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel

  9. A virtual dosimetry audit - Towards transferability of gamma index analysis between clinical trial QA groups.

    Science.gov (United States)

    Hussein, Mohammad; Clementel, Enrico; Eaton, David J; Greer, Peter B; Haworth, Annette; Ishikura, Satoshi; Kry, Stephen F; Lehmann, Joerg; Lye, Jessica; Monti, Angelo F; Nakamura, Mitsuhiro; Hurkmans, Coen; Clark, Catharine H

    2017-12-01

    Quality assurance (QA) for clinical trials is important. Lack of compliance can affect trial outcome. Clinical trial QA groups have different methods of dose distribution verification and analysis, all with the ultimate aim of ensuring trial compliance. The aim of this study was to gain a better understanding of different processes to inform future dosimetry audit reciprocity. Six clinical trial QA groups participated. Intensity modulated treatment plans were generated for three different cases. A range of 17 virtual 'measurements' were generated by introducing a variety of simulated perturbations (such as MLC position deviations, dose differences, gantry rotation errors, Gaussian noise) to three different treatment plan cases. Participants were blinded to the 'measured' data details. Each group analysed the datasets using their own gamma index (γ) technique and using standardised parameters for passing criteria, lower dose threshold, γ normalisation and global γ. For the same virtual 'measured' datasets, different results were observed using local techniques. For the standardised γ, differences in the percentage of points passing with γ audit has been an informative step in understanding differences in the verification of measured dose distributions between different clinical trial QA groups. This work lays the foundations for audit reciprocity between groups, particularly with more clinical trials being open to international recruitment. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Discussion of QA grading for AP1000 NP plant

    International Nuclear Information System (INIS)

    Luo Shuiyun; Zhang Qingchuan

    2012-01-01

    The grading method of quality assurance for the following AP1000 project is presented based on the Westinghouse classification principle, referring to the classification method of the AP1000 self-reliance supporting project and considering the factors of classification, which can meet the requirements of domestic nuclear safety regulation and standard of the QA classification. (authors)

  11. SU-D-BRC-02: Application of Six Sigma Approach to Improve the Efficiency of Patient-Specific QA in Proton Therapy

    International Nuclear Information System (INIS)

    LAH, J; Shin, D; Manger, R; Kim, G

    2016-01-01

    Purpose: To show how the Six Sigma DMAIC (Define-Measure-Analyze-Improve-Control) can be used for improving and optimizing the efficiency of patient-specific QA process by designing site-specific range tolerances. Methods: The Six Sigma tools (process flow diagram, cause and effect, capability analysis, Pareto chart, and control chart) were utilized to determine the steps that need focus for improving the patient-specific QA process. The patient-specific range QA plans were selected according to 7 treatment site groups, a total of 1437 cases. The process capability index, Cpm was used to guide the tolerance design of patient site-specific range. We also analyzed the financial impact of this project. Results: Our results suggested that the patient range measurements were non-capable at the current tolerance level of ±1 mm in clinical proton plans. The optimized tolerances were calculated for treatment sites. Control charts for the patient QA time were constructed to compare QA time before and after the new tolerances were implemented. It is found that overall processing time was decreased by 24.3% after establishing new site-specific range tolerances. The QA failure for whole process in proton therapy would lead up to a 46% increase in total cost. This result can also predict how costs are affected by changes in adopting the tolerance design. Conclusion: We often believe that the quality and performance of proton therapy can easily be improved by merely tightening some or all of its tolerance requirements. This can become costly, however, and it is not necessarily a guarantee of better performance. The tolerance design is not a task to be undertaken without careful thought. The Six Sigma DMAIC can be used to improve the QA process by setting optimized tolerances. When tolerance design is optimized, the quality is reasonably balanced with time and cost demands.

  12. SU-E-T-760: Tolerance Design for Site-Specific Range in Proton Patient QA Process Using the Six Sigma Model

    International Nuclear Information System (INIS)

    Lah, J; Shin, D; Kim, G

    2015-01-01

    Purpose: To show how tolerance design and tolerancing approaches can be used to predict and improve the site-specific range in patient QA process in implementing the Six Sigma. Methods: In this study, patient QA plans were selected according to 6 site-treatment groups: head &neck (94 cases), spine (76 cases), lung (89 cases), liver (53 cases), pancreas (55 cases), and prostate (121 cases), treated between 2007 and 2013. We evaluated a model of the Six Sigma that determines allowable deviations in design parameters and process variables in patient-specific QA, where possible, tolerance may be loosened, then customized if it necessary to meet the functional requirements. A Six Sigma problem-solving methodology is known as DMAIC phases, which are used stand for: Define a problem or improvement opportunity, Measure process performance, Analyze the process to determine the root causes of poor performance, Improve the process by fixing root causes, Control the improved process to hold the gains. Results: The process capability for patient-specific range QA is 0.65 with only ±1 mm of tolerance criteria. Our results suggested the tolerance level of ±2–3 mm for prostate and liver cases and ±5 mm for lung cases. We found that customized tolerance between calculated and measured range reduce that patient QA plan failure and almost all sites had failure rates less than 1%. The average QA time also improved from 2 hr to less than 1 hr for all including planning and converting process, depth-dose measurement and evaluation. Conclusion: The objective of tolerance design is to achieve optimization beyond that obtained through QA process improvement and statistical analysis function detailing to implement a Six Sigma capable design

  13. SU-D-BRC-02: Application of Six Sigma Approach to Improve the Efficiency of Patient-Specific QA in Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    LAH, J [Myongji Hospital, Goyang-si (Korea, Republic of); Shin, D [Proton Therapy Center, National Cancer Center, Goyang (Korea, Republic of); Manger, R; Kim, G [University of California, San Diego, La Jolla, CA (United States)

    2016-06-15

    Purpose: To show how the Six Sigma DMAIC (Define-Measure-Analyze-Improve-Control) can be used for improving and optimizing the efficiency of patient-specific QA process by designing site-specific range tolerances. Methods: The Six Sigma tools (process flow diagram, cause and effect, capability analysis, Pareto chart, and control chart) were utilized to determine the steps that need focus for improving the patient-specific QA process. The patient-specific range QA plans were selected according to 7 treatment site groups, a total of 1437 cases. The process capability index, Cpm was used to guide the tolerance design of patient site-specific range. We also analyzed the financial impact of this project. Results: Our results suggested that the patient range measurements were non-capable at the current tolerance level of ±1 mm in clinical proton plans. The optimized tolerances were calculated for treatment sites. Control charts for the patient QA time were constructed to compare QA time before and after the new tolerances were implemented. It is found that overall processing time was decreased by 24.3% after establishing new site-specific range tolerances. The QA failure for whole process in proton therapy would lead up to a 46% increase in total cost. This result can also predict how costs are affected by changes in adopting the tolerance design. Conclusion: We often believe that the quality and performance of proton therapy can easily be improved by merely tightening some or all of its tolerance requirements. This can become costly, however, and it is not necessarily a guarantee of better performance. The tolerance design is not a task to be undertaken without careful thought. The Six Sigma DMAIC can be used to improve the QA process by setting optimized tolerances. When tolerance design is optimized, the quality is reasonably balanced with time and cost demands.

  14. SU-E-T-760: Tolerance Design for Site-Specific Range in Proton Patient QA Process Using the Six Sigma Model

    Energy Technology Data Exchange (ETDEWEB)

    Lah, J [Myongji Hospital, Goyang, Gyeonggi-do (Korea, Republic of); Shin, D [National Cancer Center, Goyang-si, Gyeonggi-do (Korea, Republic of); Kim, G [University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: To show how tolerance design and tolerancing approaches can be used to predict and improve the site-specific range in patient QA process in implementing the Six Sigma. Methods: In this study, patient QA plans were selected according to 6 site-treatment groups: head &neck (94 cases), spine (76 cases), lung (89 cases), liver (53 cases), pancreas (55 cases), and prostate (121 cases), treated between 2007 and 2013. We evaluated a model of the Six Sigma that determines allowable deviations in design parameters and process variables in patient-specific QA, where possible, tolerance may be loosened, then customized if it necessary to meet the functional requirements. A Six Sigma problem-solving methodology is known as DMAIC phases, which are used stand for: Define a problem or improvement opportunity, Measure process performance, Analyze the process to determine the root causes of poor performance, Improve the process by fixing root causes, Control the improved process to hold the gains. Results: The process capability for patient-specific range QA is 0.65 with only ±1 mm of tolerance criteria. Our results suggested the tolerance level of ±2–3 mm for prostate and liver cases and ±5 mm for lung cases. We found that customized tolerance between calculated and measured range reduce that patient QA plan failure and almost all sites had failure rates less than 1%. The average QA time also improved from 2 hr to less than 1 hr for all including planning and converting process, depth-dose measurement and evaluation. Conclusion: The objective of tolerance design is to achieve optimization beyond that obtained through QA process improvement and statistical analysis function detailing to implement a Six Sigma capable design.

  15. Comparability between NQA-1 and the QA programs for analytical laboratories within the nuclear industry and EPA hazardous waste laboratories

    International Nuclear Information System (INIS)

    English, S.L.; Dahl, D.R.

    1989-01-01

    There is increasing cooperation between the Department of Energy (DOE), Department of Defense (DOD), and the Environmental Protection Agency (EPA) in the activities associated with monitoring and clean-up of hazardous wastes. Pacific Northwest Laboratory (PNL) examined the quality assurance/quality control programs that the EPA requires of the private sector when performing routine analyses of hazardous wastes to confirm how or if the requirements correspond with PNL's QA program based upon NQA-1. This paper presents the similarities and differences between NQA-1 and the QA program identified in ASTM-C1009-83, Establishing a QA Program for Analytical Chemistry Laboratories within the Nuclear Industry; EPA QAMS-005/80, Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans, which is referenced in Statements of Work for CERCLA analytical activities; and Chapter 1 of SW-846, which is used in analyses of RCRA samples. The EPA QA programs for hazardous waste analyses are easily encompassed within an already established NQA-1 QA program. A few new terms are introduced and there is an increased emphasis upon the QC/verification, but there are many of the same basic concepts in all the programs

  16. SU-E-T-392: Evaluation of Ion Chamber/film and Log File Based QA to Detect Delivery Errors

    International Nuclear Information System (INIS)

    Nelson, C; Mason, B; Kirsner, S; Ohrt, J

    2015-01-01

    Purpose: Ion chamber and film (ICAF) is a method used to verify patient dose prior to treatment. More recently, log file based QA has been shown as an alternative for measurement based QA. In this study, we delivered VMAT plans with and without errors to determine if ICAF and/or log file based QA was able to detect the errors. Methods: Using two VMAT patients, the original treatment plan plus 7 additional plans with delivery errors introduced were generated and delivered. The erroneous plans had gantry, collimator, MLC, gantry and collimator, collimator and MLC, MLC and gantry, and gantry, collimator, and MLC errors. The gantry and collimator errors were off by 4 0 for one of the two arcs. The MLC error introduced was one in which the opening aperture didn’t move throughout the delivery of the field. For each delivery, an ICAF measurement was made as well as a dose comparison based upon log files. Passing criteria to evaluate the plans were ion chamber less and 5% and film 90% of pixels pass the 3mm/3% gamma analysis(GA). For log file analysis 90% of voxels pass the 3mm/3% 3D GA and beam parameters match what was in the plan. Results: Two original plans were delivered and passed both ICAF and log file base QA. Both ICAF and log file QA met the dosimetry criteria on 4 of the 12 erroneous cases analyzed (2 cases were not analyzed). For the log file analysis, all 12 erroneous plans alerted a mismatch in delivery versus what was planned. The 8 plans that didn’t meet criteria all had MLC errors. Conclusion: Our study demonstrates that log file based pre-treatment QA was able to detect small errors that may not be detected using an ICAF and both methods of were able to detect larger delivery errors

  17. SU-E-T-636: ProteusONE Machine QA Procedure and Stabiity Study: Half Year Clinical Operation

    Energy Technology Data Exchange (ETDEWEB)

    Freund, D; Ding, X; Wu, H; Zhang, J; Syh, J; Syh, J; Patel, B; Song, X [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2015-06-15

    Purpose: The objective of this study is to evaluate the stability of ProteusOne, the 1st commercial PBS proton system, throughout the daily QA and monthly over 6 month clinical operation. Method: Daily QA test includes IGRT position/repositioning, output in the middle of SOBP, beam flatness, symmetry, inplane and crossplane dimensions as well as energy range check. Daily range shifter QA consist of output, symmetry and field size checks to make sure its integrity. In 30 mins Daily QA test, all the measurements are performed using the MatriXXPT (IBA dosimetry). The data from these measurement was collected and compare over the first 6 month of clinical operation. In addition to the items check in daily QA, the summary also includes the monthly QA gantry star shots, absolute position check using a novel device, XRV-100. Results: Average machine output at the center of the spread out bragg peak was 197.5±.8 cGy and was within 1%of the baseline at 198.4 cGy. Beam flatness was within 1% cross plane with an average of 0.67±0.12% and 2% in-plane with an average of 1.08±0.17% compared to baseline measurements of 0.6 and 1.03, respectively. In all cases the radiation isocenter shift was less than or equal to 1mm. Output for the range shifter was within 2% for each individual measurement and averaged 34.4±.2cGy compare to a baseline reading of 34.5cGy. The average range shifter in and cross plane field size measurements were 19.8±0.5cm and 20.5±0.4cm compared with baseline values of 20.19cm and 20.79cm, respectively. Range shifter field symmetry had an average of less 1% for both in-plane and cross plane measurements. Conclusion: All machine metrics over the past 6 months have proved to be stable. Although, some averages are outside the baseline measurement they are within 1% tolerance and the deviation across all measurements is minimal.

  18. SU-E-T-636: ProteusONE Machine QA Procedure and Stabiity Study: Half Year Clinical Operation

    International Nuclear Information System (INIS)

    Freund, D; Ding, X; Wu, H; Zhang, J; Syh, J; Syh, J; Patel, B; Song, X

    2015-01-01

    Purpose: The objective of this study is to evaluate the stability of ProteusOne, the 1st commercial PBS proton system, throughout the daily QA and monthly over 6 month clinical operation. Method: Daily QA test includes IGRT position/repositioning, output in the middle of SOBP, beam flatness, symmetry, inplane and crossplane dimensions as well as energy range check. Daily range shifter QA consist of output, symmetry and field size checks to make sure its integrity. In 30 mins Daily QA test, all the measurements are performed using the MatriXXPT (IBA dosimetry). The data from these measurement was collected and compare over the first 6 month of clinical operation. In addition to the items check in daily QA, the summary also includes the monthly QA gantry star shots, absolute position check using a novel device, XRV-100. Results: Average machine output at the center of the spread out bragg peak was 197.5±.8 cGy and was within 1%of the baseline at 198.4 cGy. Beam flatness was within 1% cross plane with an average of 0.67±0.12% and 2% in-plane with an average of 1.08±0.17% compared to baseline measurements of 0.6 and 1.03, respectively. In all cases the radiation isocenter shift was less than or equal to 1mm. Output for the range shifter was within 2% for each individual measurement and averaged 34.4±.2cGy compare to a baseline reading of 34.5cGy. The average range shifter in and cross plane field size measurements were 19.8±0.5cm and 20.5±0.4cm compared with baseline values of 20.19cm and 20.79cm, respectively. Range shifter field symmetry had an average of less 1% for both in-plane and cross plane measurements. Conclusion: All machine metrics over the past 6 months have proved to be stable. Although, some averages are outside the baseline measurement they are within 1% tolerance and the deviation across all measurements is minimal

  19. Manufacturing and QA of adaptors for LHC

    International Nuclear Information System (INIS)

    Madhu Murthy, V.; Dwivedi, J.; Goswami, S.G.; Soni, H.C.; Mainaud Durand, H.; Quesnel, J.P.; )

    2006-01-01

    The LHC low beta quadrupoles, have very tight alignment tolerances and are located in areas with strong radiation field. They require remote re-alignment, by motorized jacks, based on the feedback of alignment sensors of each magnet. Jacks designed to support arc cryomagnets of LHC are modified and motorized with the help of adaptors. Two types of adapters, for vertical and transverse axes of the jacks, were developed and supplied through collaboration between RRCAT, DAE, India and CERN, Geneva. This paper describes their functional requirements, manufacture and quality assurance (QA). (author)

  20. Using a User-Interactive QA System for Personalized E-Learning

    Science.gov (United States)

    Hu, Dawei; Chen, Wei; Zeng, Qingtian; Hao, Tianyong; Min, Feng; Wenyin, Liu

    2008-01-01

    A personalized e-learning framework based on a user-interactive question-answering (QA) system is proposed, in which a user-modeling approach is used to capture personal information of students and a personalized answer extraction algorithm is proposed for personalized automatic answering. In our approach, a topic ontology (or concept hierarchy)…

  1. TH-A-BRC-03: AAPM TG218: Measurement Methods and Tolerance Levels for Patient-Specific IMRT Verification QA

    Energy Technology Data Exchange (ETDEWEB)

    Miften, M. [University of Colorado School of Medicine (United States)

    2016-06-15

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  2. TH-A-BRC-03: AAPM TG218: Measurement Methods and Tolerance Levels for Patient-Specific IMRT Verification QA

    International Nuclear Information System (INIS)

    Miften, M.

    2016-01-01

    of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

  3. SU-F-T-271: Comparing IMRT QA Pass Rates Before and After MLC Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Mazza, A; Perrin, D; Fontenot, J [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States)

    2016-06-15

    Purpose: To compare IMRT QA pass rates before and after an in-house MLC leaf calibration procedure. Methods: The MLC leaves and backup jaws on four Elekta linear accelerators with MLCi2 heads were calibrated using the EPID-based RIT Hancock Test as the means for evaluation. The MLCs were considered to be successfully calibrated when they could pass the Hancock Test with criteria of 1 mm jaw position tolerance, and 1 mm leaf position tolerance. IMRT QA results were collected pre- and postcalibration and analyzed using gamma analysis with 3%/3mm DTA criteria. AAPM TG-119 test plans were also compared pre- and post-calibration, at both 2%/2mm DTA and 3%/3mm DTA. Results: A weighted average was performed on the results for all four linear accelerators. The pre-calibration IMRT QA pass rate was 98.3 ± 0.1%, compared with the post-calibration pass rate of 98.5 ± 0.1%. The TG-119 test plan results showed more of an improvement, particularly at the 2%/2mm criteria. The averaged results were 89.1% pre and 96.1% post for the C-shape plan, 94.8% pre and 97.1% post for the multi-target plan, 98.6% pre and 99.7% post for the prostate plan, 94.7% pre and 94.8% post for the head/neck plan. Conclusion: The patient QA results did not show statistically significant improvement at the 3%/3mm DTA criteria after the MLC calibration procedure. However, the TG-119 test cases did show significant improvement at the 2%/2mm level.

  4. SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J; Farrokhkish, M; Norrlinger, B; Wang, Y [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Heaton, R; Jaffray, D; Islam, M [Princess Margaret Cancer Centre, Toronto, Ontario (Canada); University of Toronto, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial

  5. SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor

    International Nuclear Information System (INIS)

    Jung, J; Farrokhkish, M; Norrlinger, B; Wang, Y; Heaton, R; Jaffray, D; Islam, M

    2015-01-01

    Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using a conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm 2 field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm 2 aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial interests with

  6. M073: Monte Carlo generated spectra for QA/QC of automated NAA routine

    International Nuclear Information System (INIS)

    Jackman, K.R.; Biegalski, S.R.

    2004-01-01

    A quality check for an automated system of analyzing large sets of neutron activated samples has been developed. Activated samples are counted with an HPGe detector, in conjunction with an automated sample changer and spectral analysis tools, controlled by the Canberra GENIE 2K and REXX software. After each sample is acquired and analyzed, a Microsoft Visual Basic program imports the results into a template Microsoft Excel file where the final concentrations, uncertainties, and detection limits are determined. Standard reference materials are included in each set of 40 samples as a standard quality assurance/quality control (QA/QC) test. A select group of sample spectra are also visually reviewed to check the peak fitting routines. A reference spectrum was generated in MCNP 4c2 using an F8, pulse height, tally with a detector model of the actual detector used in counting. The detector model matches the detector resolution, energy calibration, and counting geometry. The generated spectrum also contained a radioisotope matrix that was similar to what was expected in the samples. This spectrum can then be put through the automated system and analyzed along with the other samples. The automated results are then compared to expected results for QA/QC assurance.

  7. Expansion of polyalanine tracts in the QA domain may play a critical ...

    Indian Academy of Sciences (India)

    2015-09-03

    Sep 3, 2015 ... role in the clavicular development of cleidocranial dysplasia. LI-ZHENG ... RUNX2 mutation have been identified in nearly 500 families with CCD ... tracts in the QA domain of RUNX2 influences the transcrip- tional activity of ...

  8. SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mullins, JP; Deufel, CL [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we

  9. SU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.

    Science.gov (United States)

    Hosier, K; Wu, C; Beck, K; Radevic, M; Asche, D; Bareng, J; Kroner, A; Lehmann, J; Logsdon, M; Dutton, S; Rosenthal, S

    2012-06-01

    To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark field, flood field, and 40×40 diagonal profile for beam profile correction. Additional corrections to account for off-axis and support arm backscatter are needed for larger field sizes. Since Elekta iViewGT system does not export gantry angle with images, a third-party inclinometer must be physically mounted to back of linac gantry and synchronized with data acquisition via iViewGT PC clock. A T/2 offset correctly correlates image and gantry angle for arc plans due to iView image time stamp at the end of data acquisition for each image. For both Varian and Elekta panels, a 5 MU 10×10 calibration field is used to account for the nonlinear MU to dose response at higher energies. Acquired EPID images are deconvolved via a high pass filter in Fourier space and resultant fluence maps are used to reconstruct a 3D dose 'delivered' to patient using DosimetryCheck. Results are compared to patient 3D dose computed by TPS using a 3D-gamma analysis. 120 IMRT and 100 VMAT cases are reported. Two 3D gamma quantities (Gamma(V10) and Gamma(PTV)) are proposed for evaluating QA results. The Gamma(PTV) is sensitive to MLC offsets while Gamma(V10) is sensitive to gantry rotations. When a 3mm/3% criteria and 90% or higher 3D gamma pass rate is used, all IMRT and 90% of VMAT QA pass QA. After appropriate calibration of aSi panels and setup of image acquisition systems, EPID based 3D dose reconstruction method is found clinically feasible. © 2012 American Association of Physicists in Medicine.

  10. SU-E-T-646: Quality Assurance of Truebeam Multi-Leaf Collimator Using a MLC QA Phantom

    International Nuclear Information System (INIS)

    Zhang, J; Lu, J; Hong, D

    2015-01-01

    Purpose: To perform a routine quality assurance procedure for Truebeam multi-leaf collimator (MLC) using MLC QA phantom, verify the stability and reliability of MLC during the treatment. Methods: MLC QA phantom is a specialized phantom for MLC quality assurance (QA), and contains five radio-opaque spheres that are embedded in an “L” shape. The phantom was placed isocentrically on the Truebeam treatment couch for the tests. A quality assurance plan was setted up in the Eclipse v10.0, the fields that need to be delivered in order to acquire the necessary images, the MLC shapes can then be obtained by the images. The images acquired by the electronic portal imaging device (EPID), and imported into the PIPSpro software for the analysis. The tests were delivered twelve weeks (once a week) to verify consistency of the delivery, and the images are acquired in the same manner each time. Results: For the Leaf position test, the average position error was 0.23mm±0.02mm (range: 0.18mm∼0.25mm). The Leaf width was measured at the isocenter, the average error was 0.06mm±0.02mm (range: 0.02mm∼0.08mm) for the Leaf width test. Multi-Port test showed the dynamic leaf shift error, the average error was 0.28mm±0.03mm (range: 0.2mm∼0.35mm). For the leaf transmission test, the average inter-leaf leakage value was 1.0%±0.17% (range: 0.8%∼1.3%) and the average inter-bank leakage value was 32.6%±2.1% (range: 30.2%∼36.1%). Conclusion: By the test of 12 weeks, the MLC system of the Truebeam is running in a good condition and the MLC system can be steadily and reliably carried out during the treatment. The MLC QA phantom is a useful test tool for the MLC QA

  11. USGS QA Plan: Certification of digital airborne mapping products

    Science.gov (United States)

    Christopherson, J.

    2007-01-01

    To facilitate acceptance of new digital technologies in aerial imaging and mapping, the US Geological Survey (USGS) and its partners have launched a Quality Assurance (QA) Plan for Digital Aerial Imagery. This should provide a foundation for the quality of digital aerial imagery and products. It introduces broader considerations regarding processes employed by aerial flyers in collecting, processing and delivering data, and provides training and information for US producers and users alike.

  12. Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A

    International Nuclear Information System (INIS)

    Kim, Chan Yong; Jae, Young Wan; Park, Heung Deuk; Lee, Jae Hee

    2005-01-01

    Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment. field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and we were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ±2%, and measured laser alignment, field size, SSD indicator in range within ±1 mm. We can enforce output measurement and appliances check conveniently, and time was reduced and was able to raise efficiency of business. We were able to bring a cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  13. Summary Report for the Evaluation of Current QA Processes Within the FRMAC FAL and EPA MERL.

    Energy Technology Data Exchange (ETDEWEB)

    Shanks, Sonoya T.; Ted Redding; Lynn Jaussi; Allen, Mark B.; Fournier, Sean Donovan; Leonard, Elliott J.

    2017-04-01

    The Federal Radiological Monitoring and Assessment Center (FRMAC) relies on accurate and defensible analytical laboratory data to support its mission. Therefore, FRMAC must ensure that the environmental analytical laboratories providing analytical services maintain an ongoing capability to provide accurate analytical results to DOE. It is undeniable that the more Quality Assurance (QA) and Quality Control (QC) measures required of the laboratory, the less resources that are available for analysis of response samples. Being that QA and QC measures in general are understood to comprise a major effort related to a laboratory’s operations, requirements should only be considered if they are deemed “value-added” for the FRMAC mission. This report provides observations of areas for improvement and potential interoperability opportunities in the areas of Batch Quality Control Requirements, Written Communications, Data Review Processes, Data Reporting Processes, along with the lessons learned as they apply to items in the early phase of a response that will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA assets.

  14. SU-F-T-251: The Quality Assurance for the Heavy Patient Load Department in the Developing Country: The Primary Experience of An Entire Workflow QA Process Management in Radiotherapy

    International Nuclear Information System (INIS)

    Xie, J; Wang, J; Peng, J; Chen, J; Hu, W

    2016-01-01

    Purpose: To implement an entire workflow quality assurance (QA) process in the radiotherapy department and to reduce the error rates of radiotherapy based on the entire workflow management in the developing country. Methods: The entire workflow QA process management starts from patient registration to the end of last treatment including all steps through the entire radiotherapy process. Error rate of chartcheck is used to evaluate the the entire workflow QA process. Two to three qualified senior medical physicists checked the documents before the first treatment fraction of every patient. Random check of the treatment history during treatment was also performed. A total of around 6000 patients treatment data before and after implementing the entire workflow QA process were compared from May, 2014 to December, 2015. Results: A systemic checklist was established. It mainly includes patient’s registration, treatment plan QA, information exporting to OIS(Oncology Information System), documents of treatment QAand QA of the treatment history. The error rate derived from the chart check decreases from 1.7% to 0.9% after our the entire workflow QA process. All checked errors before the first treatment fraction were corrected as soon as oncologist re-confirmed them and reinforce staff training was accordingly followed to prevent those errors. Conclusion: The entire workflow QA process improved the safety, quality of radiotherapy in our department and we consider that our QA experience can be applicable for the heavily-loaded radiotherapy departments in developing country.

  15. SU-F-T-251: The Quality Assurance for the Heavy Patient Load Department in the Developing Country: The Primary Experience of An Entire Workflow QA Process Management in Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Xie, J; Wang, J; Peng, J; Chen, J; Hu, W [Fudan University Shanghai Cancer Center, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: To implement an entire workflow quality assurance (QA) process in the radiotherapy department and to reduce the error rates of radiotherapy based on the entire workflow management in the developing country. Methods: The entire workflow QA process management starts from patient registration to the end of last treatment including all steps through the entire radiotherapy process. Error rate of chartcheck is used to evaluate the the entire workflow QA process. Two to three qualified senior medical physicists checked the documents before the first treatment fraction of every patient. Random check of the treatment history during treatment was also performed. A total of around 6000 patients treatment data before and after implementing the entire workflow QA process were compared from May, 2014 to December, 2015. Results: A systemic checklist was established. It mainly includes patient’s registration, treatment plan QA, information exporting to OIS(Oncology Information System), documents of treatment QAand QA of the treatment history. The error rate derived from the chart check decreases from 1.7% to 0.9% after our the entire workflow QA process. All checked errors before the first treatment fraction were corrected as soon as oncologist re-confirmed them and reinforce staff training was accordingly followed to prevent those errors. Conclusion: The entire workflow QA process improved the safety, quality of radiotherapy in our department and we consider that our QA experience can be applicable for the heavily-loaded radiotherapy departments in developing country.

  16. SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

    International Nuclear Information System (INIS)

    Court, L; Wang, H; Aten, D; Chi, P; Gao, S; Aristophanous, M; Balter, P; Brown, D; Yock, A; Maddox, B; MacGregor, H

    2016-01-01

    Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch

  17. SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

    Energy Technology Data Exchange (ETDEWEB)

    Court, L; Wang, H; Aten, D; Chi, P; Gao, S; Aristophanous, M; Balter, P [UT MD Anderson Cancer Center, Houston, TX (United States); Brown, D; Yock, A [University of California, San Diego, La Jolla, CA (United States); Maddox, B [Brigham & Women’s Hospital, Boston, MA (United States); MacGregor, H [University of Cape Town (South Africa)

    2016-06-15

    Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch

  18. Development of database and QA systems for post closure performance assessment on a potential HLW repository

    International Nuclear Information System (INIS)

    Hwang, Y. S.; Kim, S. G.; Kang, C. H.

    2002-01-01

    In TSPA of long-term post closure radiological safety on permanent disposal of HLW in Korea, appropriate management of input and output data through QA is necessary. The robust QA system is developed using the T2R3 principles applicable for five major steps in R and D's. The proposed system is implemented in the web-based system so that all participants in TSRA are able to access the system. In addition, the internet based input database for TSPA is developed. Currently data from literature surveys, domestic laboratory and field experiments as well as expert elicitation are applied for TSPA

  19. Worldwide QA networks for radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Izewska, J.; Svensson, H.; Ibbott, G.

    2002-01-01

    institutions participating in the U.S. National Cancer Institute's (NCI's) co-operative clinical trials. The RPC currently monitors approximately 1300 centres throughout the USA, Canada and several other countries. The audit tools include, in addition to mailed TLD, review of the institution's dosimetry data, the treatment records of patients entered into trials, and the institution's QA programme. Anthropomorphic phantoms have been developed to evaluate specific treatment techniques. Other currently operating external audit programmes have been either associated with national and international clinical trial groups, similarly to RPC, e.g. EORTC (European Organisation for Research in Treatment of Cancer) in Europe, MRC (Medical Research Council) in the UK, or have been one-off national dosimetry intercomparison exercises, carried out to test various levels of radiotherapy dosimetry, e.g. in Sweden, the Netherlands, Belgium, Switzerland, Australia. Some individual countries have set up comprehensive regular audits of radiotherapy centres, including QA programmes, equipment and dosimetry, e.g. Finland, New Zealand. The IAEA supports its Member States in developing national programmes for TLD based QA audits in radiotherapy dosimetry and whenever possible, establishes links between the national programmes and the IAEA's Dosimetry Laboratory. It disseminates its standardised TLD methodology and provides technical back up to national TLD networks assuring at the same time traceability to primary dosimetry standards. There are several countries (Argentina, Algeria, Brazil, China, Colombia, Cuba, Czech Republic, India, Israel, Malaysia, Philippines, Poland and Vietnam) that have established TLD programmes to audit radiotherapy beams in their countries with assistance of the IAEA. Recently a new IAEA project has been initiated for national TLD audits in non-reference conditions as significant numbers of deviations in non-reference situations, as used clinically on patients, have been

  20. SU-F-T-308: Mobius FX Evaluation and Comparison Against a Commercial 4D Detector Array for VMAT Plan QA

    International Nuclear Information System (INIS)

    Vazquez Quino, L; Huerta Hernandez, C; Morrow, A; Massingill, B; Rangaraj, D

    2016-01-01

    Purpose: To evaluate the use of MobiusFX as a pre-treatment verification IMRT QA tool and compare it with a commercial 4D detector array for VMAT plan QA. Methods: 15 VMAT plan QA of different treatment sites were delivered and measured by traditional means with the 4D detector array ArcCheck (Sun Nuclear corporation) and at the same time measurement in linac treatment logs (Varian Dynalogs files) were analyzed from the same delivery with MobiusFX software (Mobius Medical Systems). VMAT plan QAs created in Eclipse treatment planning system (Varian) in a TrueBeam linac machine (Varian) were delivered and analyzed with the gamma analysis routine from SNPA software (Sun Nuclear corporation). Results: Comparable results in terms of the gamma analysis with 99.06% average gamma passing with 3%,3mm passing rate is observed in the comparison among MobiusFX, ArcCheck measurements, and the Treatment Planning System dose calculated. When going to a stricter criterion (1%,1mm) larger discrepancies are observed in different regions of the measurements with an average gamma of 66.24% between MobiusFX and ArcCheck. Conclusion: This work indicates the potential for using MobiusFX as a routine pre-treatment patient specific IMRT method for quality assurance purposes and its advantages as a phantom-less method which reduce the time for IMRT QA measurement. MobiusFX is capable of produce similar results of those by traditional methods used for patient specific pre-treatment verification VMAT QA. Even the gamma results comparing to the TPS are similar the analysis of both methods show that the errors being identified by each method are found in different regions. Traditional methods like ArcCheck are sensitive to setup errors and dose difference errors coming from the linac output. On the other hand linac log files analysis record different errors in the VMAT QA associated with the MLCs and gantry motion that by traditional methods cannot be detected.

  1. SU-E-T-422: Correlation Between 2D Passing Rates and 3D Dose Differences for Pretreatment VMAT QA

    International Nuclear Information System (INIS)

    Jin, X; Xie, C

    2014-01-01

    Purpose: Volumetric modulated arc therapy (VMAT) quality assurance (QA) is typically using QA methods and action levels taken from fixedbeam intensity-modulated radiotherapy (IMRT) QA methods. However, recent studies demonstrated that there is no correlation between the percent gamma passing rate (%GP) and the magnitude of dose discrepancy between the planned dose and the actual delivered dose for IMRT. The purpose of this study is to investigate whether %GP is correlated with clinical dosimetric difference for VMAT. Methods: Twenty nasopharyngeal cancer (NPC) patients treated with dual-arc simultaneous integrated boost VMAT and 20 esophageal cancer patients treated with one-arc VMAT were enrolled in this study. Pretreatment VMAT QA was performed by a 3D diode array ArcCheck. Acceptance criteria of 2%/2mm, 3%/3mm, and 4%/4mm were applied for 2D %GP. Dose values below 10% of the per-measured normalization maximum dose were ignored.Mean DVH values obtained from 3DVH software and TPS were calculated and percentage dose differences were calculated. Statistical correlation between %GP and percent dose difference was studied by using Pearson correlation. Results: The %GP for criteria 2%/2mm, 3%/3mm, and 4%/4mm were 82.33±4.45, 93.47±2.31, 97.13±2.41, respectively. Dose differences calculated from 3DVH and TPS for beam isocenter, mean dose of PTV, maximum dose of PTV, D2 of PTV and D98 of PTV were -1.04±3.24, -0.74±1.71, 2.92±3.62, 0.89±3.29, -1.46±1.97, respectively. No correction were found between %GP and dose differences. Conclusion: There are weak correlations between the 2D %GP and dose differences calculated from 3DVH. The %GP acceptance criteria of 3%/3mm usually applied for pretreatment QA of IMRT and VMAT is not indicating strong clinical correlation with 3D dose difference. 3D dose reconstructions on patient anatomy may be necessary for physicist to predict the accuracy of delivered dose for VMAT QA

  2. Building Watson: An Overview of the DeepQA Project

    OpenAIRE

    Ferrucci, David; Brown, Eric; Chu-Carroll, Jennifer; Fan, James; Gondek, David; Kalyanpur, Aditya A.; Lally, Adam; Murdock, J. William; Nyberg, Eric; Prager, John; Schlaefer, Nico; Welty, Chris

    2010-01-01

    IBM Research undertook a challenge to build a computer system that could compete at the human champion level in real time on the American TV Quiz show, Jeopardy! The extent of the challenge includes fielding a real-time automatic contestant on the show, not merely a laboratory exercise. The Jeopardy! Challenge helped us address requirements that led to the design of the DeepQA architecture and the implementation of Watson. After 3 years of intense research and development by a core team of ab...

  3. From Q&A to Slumdog Millionaire: it’s written

    OpenAIRE

    Bulger, Laura Fernanda

    2009-01-01

    In this paper, we seek to analyse the film adaptation of Vikas Swarup’ novel, Q&A, published in 2005. Slumdog Millionaire was directed by British filmmaker Danny Boyle and released in 2008. Thus, three years after its publication, Vikas Swarup’s novel was turned into a blockbuster earning successive awards including the 2009 Best Picture Award from the Hollywood Academy. Its success was not the result of a mega “business strategy”; it was largely due to Danny Boyle’s direction and Simon Beauf...

  4. [A Quality Assurance (QA) System with a Web Camera for High-dose-rate Brachytherapy].

    Science.gov (United States)

    Hirose, Asako; Ueda, Yoshihiro; Oohira, Shingo; Isono, Masaru; Tsujii, Katsutomo; Inui, Shouki; Masaoka, Akira; Taniguchi, Makoto; Miyazaki, Masayoshi; Teshima, Teruki

    2016-03-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.

  5. A quality assurance (QA) system with a web camera for high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Hirose, Asako; Ueda, Yoshihiro; Ohira, Shingo

    2016-01-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an 192 Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.3±0.1 mm and that of dwell time errors 0.1 ± 0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size. (author)

  6. Evaluation of Uncertainty of IMRT QA Using 2 Dimensional Array Detector for Head and Neck Patients

    International Nuclear Information System (INIS)

    Ban, Tae Joon; Lee, Woo Suk; Kim, Dae Sup; Baek, Geum Mun; Kwak, Jung Won

    2011-01-01

    IMRT QA using 2 Dimensional array detector is carried out with condition for discrete dose distribution clinically. And it can affect uncertainty of evaluation using gamma method. We analyze gamma index variation according to grid size and suggest validate range of grid size for IMRT QA in Hospital. We performed QA using OniPro I'mRT system software version 1.7b on 10 patients (head and neck) for IMRT. The reference dose plane (grid size, 0.1 cm; location, [0, 0, 0]) from RTP was compared with the dose plane that has different grid size (0.1 cm, 0.5 cm, 1.0 cm, 2.0 cm, 4.0 cm) and different location (along Y-axis 0 cm, 0.2 cm, 0.5 cm, 1.0 cm). The gamma index variation was evaluated by observing the level of changes in Gamma pass rate, Average signal, Standard deviation for each case. The average signal for each grid size showed difference levels of 0%, -0.19%, -0.04%, -0.46%, -8.32% and the standard deviation for each grid size showed difference levels of 0%, -0.30%, 1.24%, -0.70%, -7.99%. The gamma pass rate for each grid size showed difference levels of 0%, 0.27%, -1.43%, 5.32%, 5.60%. The gamma evaluation results according to distance in grid size range of 0.1 cm to 1.0 cm showed good agreement with reference condition (grid size 0.1 cm) within 1.5% and over 5% in case of the grid size was greater than 2.0 cm. We recognize that the grid size of gamma evaluation can make errors of IMRT QA. So we have to consider uncertainty of gamma evaluation according to the grid size and apply smaller than 2 cm grid size to reduce error and increase accuracy clinically.

  7. Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 06: Patient-specific QA Procedure for Gated VMAT SABR Treatments using 10x Beam in Flattening-Filter Free Mode

    Energy Technology Data Exchange (ETDEWEB)

    Mestrovic, Ante; Chitsazzadeh, Shadi; Wells, Derek M.; Gray, Stephen [University of Calgary, Tom Baker Cancer Centre, Tom Baker Cancer Centre (Canada)

    2016-08-15

    Purpose: To develop a highly sensitive patient specific QA procedure for gated VMAT stereotactic ablative radiotherapy (SABR) treatments. Methods: A platform was constructed to attach the translational stage of a Quasar respiratory motion phantom to a pinpoint ion chamber insert and move the ion chamber inside the ArcCheck. The Quasar phantom controller uses a patient-specific breathing pattern to translate the ion chamber in a superior-inferior direction inside the ArcCheck. With this system the ion chamber is used to QA the correct phase of the gated delivery and the ArcCheck diodes are used to QA the overall dose distribution. This novel approach requires a single plan delivery for a complete QA of a gated plan. The sensitivity of the gating QA procedure was investigated with respect to the following parameters: PTV size, exhale duration, baseline drift, gating window size. Results: The difference between the measured dose to a point in the penumbra and the Eclipse calculated dose was under 2% for small residual motions. The QA procedure was independent of PTV size and duration of exhale. Baseline drift and gating window size, however, significantly affected the penumbral dose measurement, with differences of up to 30% compared to Eclipse. Conclusion: This study described a highly sensitive QA procedure for gated VMAT SABR treatments. The QA outcome was dependent on the gating window size and baseline drift. Analysis of additional patient breathing patterns is currently undergoing to determine a clinically relevant gating window size and an appropriate tolerance level for this procedure.

  8. ATLAS IBL Stave QA - In and Around SR1

    CERN Document Server

    Carney, Rebecca

    2013-01-01

    During the Phase-I upgrade the ATLAS Inner tracker will have a whole new layer of pixels inserted between the existing B-layer and a new, smaller, beam pipe. Briefly, there are 14 assemblies of 32 single and double-chip hybrid silicon pixel chips arranged side-by-side on light-weight, thermally conductive carbon-fibre coated carbon foam supports called staves. When the staves arrive at CERN, fully assembled, they undergo a QA procedure, which checks the power characteristics of sensors and read-out chips, and assess the quality of individual pixels.

  9. Quality assurance of 3-D conformal radiation therapy for a cooperative group trial - RTOG 3D QA center initial experience

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Purdy, James A.; Harms, William B.; Bosch, Walter R.; Oehmke, Frederick; Cox, James D.

    1996-01-01

    PURPOSE: 3-D conformal radiation therapy (3DCRT) holds promise in allowing safe escalation of radiation dose to increase the local control of prostate cancer. Prospective evaluation of this new modality requires strict quality assurance (QA). We report the results of QA review on patients receiving 3DCRT for prostate cancer on a cooperative group trial. MATERIALS and METHODS: In 1993 the NCI awarded the ACR/RTOG and nine institutions an RFA grant to study the use of 3DCRT in the treatment of prostate cancer. A phase I/II trial was developed to: a) test the feasibility of conducting 3DCRT radiation dose escalation in a cooperative group setting; b) establish the maximum tolerated radiation dose that can be delivered to the prostate; and c) quantify the normal tissue toxicity rate when using 3DCRT. In order to assure protocol compliance each participating institution was required to implement data exchange capabilities with the RTOG 3D QA center. The QA center reviews at a minimum the first five case from each participating center and spot checks subsequent submissions. For each case review the following parameters are evaluated: 1) target volume delineation, 2) normal structure delineation, 3) CT data quality, 4) field placement, 5) field shaping, and 6) dose distribution. RESULTS: Since the first patient was registered on August 23, 1994, an additional 170 patients have been accrued. Each of the nine original approved institutions has participated and three other centers have recently passed quality assurance bench marks for study participation. Eighty patients have been treated at the first dose level (68.4 Gy minimum PTV dose) and accrual is currently ongoing at the second dose level (73.8 Gy minimum PTV dose). Of the 124 cases that have undergone complete or partial QA review, 30 cases (24%) have had some problems with data exchange. Five of 67 CT scans were not acquired by protocol standards. Target volume delineation required the submitting institution

  10. The use of a commercial QA device for daily output check of a helical tomotherapy unit

    International Nuclear Information System (INIS)

    Alaei, Parham; Hui, Susanta K.; Higgins, Patrick D.; Gerbi, Bruce J.

    2006-01-01

    Helical tomotherapy radiation therapy units, due to their particular design and differences from a traditional linear accelerator, require different procedures by which to perform routine quality assurance (QA). One of the principal QA tasks that should be performed daily on any radiation therapy equipment is the output constancy check. The daily output check on a Hi-Art TomoTherapy unit is commonly performed utilizing ionization chambers placed inside a solid water phantom. This provides a good check of output at one point, but does not give any information on either energy or symmetry of the beam, unless more than one point is measured. This also has the added disadvantage that it has to be done by the physics staff. To address these issues, and to simplify the process, such that it can be performed by radiation therapists, we investigated the use of a commercially available daily QA device to perform this task. The use of this device simplifies the task of daily output constancy checks and eliminates the need for continued physics involvement. This device can also be used to monitor the constancy of beam energy and cone profile and can potentially be used to detect gross errors in the couch movement or laser alignment

  11. Experience Using DosimetryCheck software for IMRT and RapidArc Patient Pre-treatment QA and a New Feature for QA during Treatment

    International Nuclear Information System (INIS)

    Pinkerton, Arthur; Hannon, Michael; Kwag, Jae; Renner, Wendel Dean

    2010-01-01

    We have used the DosimetryCheck program with the EPID's on our Varian 2100EX's to perform pre-treatment QA on more than 350 patients, between the last quarter of 2006 and the present. The software uses the EPID measured fluences of the treatment fields to reconstruct the dose distribution in the CT planning model of the patient. Since the dose calculation algorithm, is different from that used by our Eclipse planning system, this provides an independent check of planning accuracy as well as treatment delivery. 2D and 3D dose distributions, point doses, Gamma distributions, DVH statistics and MU calculations can be compared. Absolute differences of Reference Point doses between Dosimetry Check and Eclipse average 1.20%, which is similar to the ionization chamber dose differences of 1.29% for the same patient verification plans. Examples of cases for various treatment sites and delivery modes will be presented. A Special Report in Medical Physics Vol. 37 Number 6 Pg. 2638-2644 from Mans et al at The Netherlands Cancer Institute demonstrated the ability of in vivo EPID dosimetry to detect treatment errors, that escaped other QA checks. A new version of DosimetryCheck awaiting FDA approval, is capable of successfully reconstructing the dose distribution in the patient from the EPID measured exit fluences. This can also be applied to CBCT images providing actual patient dose verification for a treatment session. This should be particularly useful for monitoring hypo-fractionated treatment regimens. Examples of this method will also be presented.

  12. How social Q&A sites are changing knowledge sharing in open source software communities

    NARCIS (Netherlands)

    Vasilescu, B.N.; Serebrenik, A.; Devanbu, P.; Filkov, V.

    2014-01-01

    Historically, mailing lists have been the preferred means for coordinating development and user support activities. With the emergence and popularity growth of social Q&A sites such as the StackExchange network (e.g., StackOverflow), this is beginning to change. Such sites offer different

  13. Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Szpala, Stanislaw; Kohli, Kirpal S. [BCCA-Fraser Valley Centre (Canada)

    2016-08-15

    Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancy of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.

  14. Land ECVs from QA4ECV using an optimal estimation framework

    Science.gov (United States)

    Muller, Jan-Peter; Kharbouche, Said; Lewis, Philip; Danne, Olaf; Blessing, Simon; Giering, Ralf; Gobron, Nadine; Lanconelli, Christian; Govaerts, Yves; Schulz, Joerg; Doutriaux-Boucher, Marie; Lattanzio, Alessio; Aoun, Youva

    2017-04-01

    In the ESA-DUE GlobAlbedo project (http://www.GlobAlbedo.org), a 15 year record of land surface albedo was generated from the European VEGETATION & MERIS sensors using optimal estimation. This was based on 3 broadbands (0.4-0.7, 0.7-3, 0.4-3µm) and fused data at level-2 after converting from spectral narrowband to these 3 broadbands with surface BRFs. A 10 year long record of land surface albedo climatology was generated from Collection 5 of the MODIS BRDF product for these same broadbands. This was employed as an a priori estimate for an optimal estimation based retrieval of land surface albedo when there were insufficient samples from the European sensors. This so-called MODIS prior was derived at 1km from the 500m MOD43A1,2 BRDF inputs every 8 days using the QA bits and the method described in the GlobAlbedo ATBD which is available from the website (http://www.globalbedo.org/docs/GlobAlbedo_Albedo_ATBD_V4.12.pdf). In the ESA-STSE WACMOS-ET project, FastOpt generated fapar & LAI based on this GlobAlbedo BRDF with associated per pixel uncertainty using the TIP framework. In the successor EU-FP7-QA4ECV* project, we have developed a 33 year record (1981-2014) of Earth surface spectral and broadband albedo (i.e. including the ocean and sea-ice) using optimal estimation for the land and where available, relevant sensors for "instantaneous" retrievals over the poles (Kharbouche & Muller, this conference). This requires the longest possible land surface spectral and broadband BRDF record that can only be supplied by a 16 year of MODIS Collection 6 BRDFs at 500m but produced on a daily basis. The CEMS Big Data computer at RAL was used to generate 7 spectral bands and 3 broadband BRDF with and without snow and snow_only. We will discuss the progress made since the start of the QA4ECV project on the production of a new fused land surface BRDF/albedo spectral and broadband CDR product based on four European sensors: MERIS, (A)ATSR(2), VEGETATION, PROBA-V and two US sensors

  15. SU-F-BRE-08: Feasibility of 3D Printed Patient Specific Phantoms for IMRT/IGRT QA

    International Nuclear Information System (INIS)

    Ehler, E; Higgins, P; Dusenbery, K

    2014-01-01

    Purpose: Test the feasibility of 3D printed, per-patient phantoms for IMRT QA to analyze the treatment delivery quality within the patient geometry. Methods: Using the head and neck region of an anthropomorphic phantom as a substitute for an actual patient, a soft-tissue equivalent model was constructed with the use of a 3D printer. A nine-field IMRT plan was constructed and dose verification measurements were performed for the 3D printed phantom. During the delivery of the IMRT QA on to the 3D printed phantom, the same patient positioning indexing system was used on the phantom and image guidance (cone beam CT) was used to localize the phantom, serving as a test of the IGRT system as well. The 3D printed phantom was designed to accommodate four radiochromic film planes (two axial, one coronal and one sagittal) and an ionization chamber measurement. As a frame of comparison, the IMRT QA was also performed on traditional phantoms. Dosimetric tolerance levels such as 3mm / 3% Gamma Index as well as 3% and 5% dose difference were considered. All detector systems were calibrated against a NIST traceable ionization chamber. Results: Comparison of results 3D printed patient phantom with the standard IMRT QA systems showed similar passing rates for the 3D printed phantom and the standard phantoms. However, the locations of the failing regions did not necessarily correlate. The 3D printed phantom was localized within 1 mm and 1° using on-board cone beam CT. Conclusion: A custom phantom was created using a 3D printer. It was determined that the use of patient specific phantoms to perform dosimetric verification and estimate the dose in the patient is feasible. In addition, end-to-end testing on a per-patient basis was possible with the 3D printed phantom. Further refinement of the phantom construction process is needed for routine clinical use

  16. SU-F-BRE-08: Feasibility of 3D Printed Patient Specific Phantoms for IMRT/IGRT QA

    Energy Technology Data Exchange (ETDEWEB)

    Ehler, E; Higgins, P; Dusenbery, K [University of Minnesota, Minneapolis, MN (United States)

    2014-06-15

    Purpose: Test the feasibility of 3D printed, per-patient phantoms for IMRT QA to analyze the treatment delivery quality within the patient geometry. Methods: Using the head and neck region of an anthropomorphic phantom as a substitute for an actual patient, a soft-tissue equivalent model was constructed with the use of a 3D printer. A nine-field IMRT plan was constructed and dose verification measurements were performed for the 3D printed phantom. During the delivery of the IMRT QA on to the 3D printed phantom, the same patient positioning indexing system was used on the phantom and image guidance (cone beam CT) was used to localize the phantom, serving as a test of the IGRT system as well. The 3D printed phantom was designed to accommodate four radiochromic film planes (two axial, one coronal and one sagittal) and an ionization chamber measurement. As a frame of comparison, the IMRT QA was also performed on traditional phantoms. Dosimetric tolerance levels such as 3mm / 3% Gamma Index as well as 3% and 5% dose difference were considered. All detector systems were calibrated against a NIST traceable ionization chamber. Results: Comparison of results 3D printed patient phantom with the standard IMRT QA systems showed similar passing rates for the 3D printed phantom and the standard phantoms. However, the locations of the failing regions did not necessarily correlate. The 3D printed phantom was localized within 1 mm and 1° using on-board cone beam CT. Conclusion: A custom phantom was created using a 3D printer. It was determined that the use of patient specific phantoms to perform dosimetric verification and estimate the dose in the patient is feasible. In addition, end-to-end testing on a per-patient basis was possible with the 3D printed phantom. Further refinement of the phantom construction process is needed for routine clinical use.

  17. Accelerator based-boron neutron capture therapy (BNCT)-clinical QA and QC

    International Nuclear Information System (INIS)

    Suzuki, Minoru; Tanaka, Hiroki; Sakurai, Yoshinori; Yong, Liu; Kashino, Genro; Kinashi, Yuko; Masunaga, Shinichiro; Ono, Koji; Maruhashi, Akira

    2009-01-01

    Alpha-particle and recoil Li atom yielded by the reaction ( 10 B, n), due to their high LET properties, efficiently and specifically kill the cancer cell that has incorporated the boron. Efficacy of this boron neutron capture therapy (BNCT) has been demonstrated mainly in the treatment of recurrent head/neck and malignant brain cancers in Kyoto University Research Reactor Institute (KUR). As the clinical trial of BNCT is to start from 2009 based on an accelerator (not on the Reactor), this paper describes the tentative outline of the standard operation procedure of BNCT for its quality assurance (QA) and quality control (QC) along the flow of its clinical practice. Personnel concerned in the practice involve the attending physician, multiple physicians in charge of BNCT, medical physicists, nurses and reactor stuff. The flow order of the actual BNCT is as follows: Pre-therapeutic evaluation mainly including informed consent and confirmation of the prescription; Therapeutic planning including setting of therapy volume, and of irradiation axes followed by meeting for stuffs' agreement, decision of irradiating field in the irradiation room leading to final decision of the axis, CT for the planning, decision of the final therapeutic plan according to Japan Atomic Energy Agency-Computational Dosimetry System (JCDS) and meeting of all related personnel for the final confirmation of therapeutic plan; and BNCT including the transport of patient to KUR, dripping of boronophenylalanine, setting up of the patient on the machine, blood sampling for pharmacokinetics, boron level measurement for decision of irradiating time, switch on/off of the accelerator, confirmation of patient's movement in the irradiated field after the neutron irradiation, blood sampling for confirmation of the boron level, and patient's leave from the room. The QA/QC check is principally to be conducted with the two-person rule. The purpose of the clinical trial is to establish the usefulness of BNCT

  18. Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements

    Energy Technology Data Exchange (ETDEWEB)

    Knill, Cory, E-mail: knillcor@gmail.com; Snyder, Michael; Rakowski, Joseph T.; Burmeister, Jay [Department of Radiation Oncology, Karmanos Cancer Institute, Detroit, Michigan 48201 and Department of Radiation Oncology, Wayne State University School of Medicine, Detroit, Michigan 48201 (United States); Zhuang, Ling [Department of Radiation Oncology, Wayne State University School of Medicine, Detroit, Michigan 48201 (United States); Matuszak, Martha [Department of Radiation Oncology, University of Michigan Health System, Ann Arbor, Michigan 48109 (United States)

    2016-05-15

    Purpose: PTW’s Octavius 1000 SRS array performs IMRT quality assurance (QA) measurements with liquid-filled ionization chambers (LICs) to allow closer detector spacing and higher resolution, compared to air-filled QA devices. However, reduced ion mobility in LICs relative to air leads to increased ion recombination effects and reduced collection efficiencies that are dependent on Linac pulse frequency and pulse dose. These pulse parameters are variable during an IMRT delivery, which affects QA results. In this study, (1) 1000 SRS collection efficiencies were measured as a function of pulse frequency and pulse dose, (2) two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: To obtain collection efficiencies, the OCTAVIUS 1000 SRS was used to measure open fields of varying pulse frequency, pulse dose, and beam energy with results normalized to air-filled chamber measurements. Changes in ratios of 1000 SRS to chamber measured dose were attributed to changing collection efficiencies, which were then correlated to pulse parameters using regression analysis. The usefulness of the derived corrections was then evaluated using 6 MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam (Varian Medical Systems) linear accelerator equipped with a high definition multileaf collimator. For the first correction, MATLAB software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information is converted to collection efficiency, and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction the MU/min in the daily 1000 SRS calibration was chosen to match the average MU/min of the volumetric modulated arc therapy plan. Effects of the two corrections on QA results were

  19. Developing a mailed phantom to implement a local QA program in Egypt radiotherapy centers

    Science.gov (United States)

    Soliman, H. A.; Aletreby, M.

    2016-07-01

    In this work, a simple method that differs from the IAEA/WHO Thermoluminescent dosimeters (TLD) postal quality assurance (QA) program is developed. A small perspex; polymethyl methacrylate (PMMA), phantom measured 50 mm × 50 mm × 50 mm is constructed to be used for absorbed dose verification of high-energy photon beams in some major radiotherapy centers in Egypt. The phantom weighted only 140.7 g with two buildup covers weighted 14.8 and 43.19 g for the Cobalt-60 and the 6-MV X-ray beams, respectively. This phantom is aimed for use in the future's external audit/QA services in Egypt for the first time. TLD-700 chips are used for testing and investigating a convenient and national dosimetry QA program. Although the used methodology is comparable to previously introduced but new system; it has smaller size, less weight, and different more available material. Comparison with the previous similar designs is introduced. Theoretical calculations were done by the commercial Eclipse treatment planning system, implementing the pencil beam convolution algorithm to verify the accuracy of the experimental calculation of the dose conversion factor of water to the perspex phantom. The new constructed small phantom and methodology was applied in 10 participating radiotherapy centers. The absorbed dose was verified under the reference conditions for both 60Co and 6-MV high-energy photon beams. The checked beams were within the 5% limit except for four photon beams. There was an agreement of 0.2% between our experimental data and those previously published confirming the validity of the applied method in verifying radiotherapy absorbed dose.

  20. Establishing QC/QA system in the fabrication of nuclear fuel assemblies

    International Nuclear Information System (INIS)

    Suh, K.S.; Choi, S.K.; Park, H.G.; Park, T.G.; Chung, J.S.

    1980-01-01

    Quality control instruction manuals and inspection methods for UO 2 powder and zircaloy materials as the material control, and for UO 2 pellets and nuclear fuel rods as the process control were established. And for the establishment of Q.A programme, the technical specifications of the purchased materials, the control regulation of the measuring and testing equipments, and traceability chart as a part of document control have also been provided and practically applied to the fuel fabrication process

  1. Retrospective analysis of 'gamma distribution' based IMRT QA criteria

    International Nuclear Information System (INIS)

    Wen, C.; Chappell, R.A.

    2010-01-01

    Full text: IMRT has been implemented into clinical practice at Royal Hobart Hospital (RHH) since mid 2006 for treating patients with Head and Neck (H and N) or prostate tumours. A local quality assurance (QA) acceptance criteria based on 'gamma distribution' for approving IMRT plan was developed and implemented in early 2007. A retrospective analysis of such criteria over 194 clinical cases will be presented. The RHH IMRT criteria was established with assumption that gamma distribution obtained through inter-comparison of 2 D dose maps between planned and delivered was governed by a positive-hail' normal distribution. A commercial system-MapCheck was used for 2 D dose map comparison with a built-in gamma analysis tool. Gamma distribution histogram was generated and recorded for all cases. By retrospectively analysing those distributions using curve fitting technique, a statistical gamma distribution can be obtained and evaluated. This analytical result can be used for future IMRT planing and treatment delivery. The analyses indicate that gamma distribution obtained through MapCheckTM is well under the normal distribution, particularly for prostate cases. The applied pass/fail criteria is not overly sensitive to identify 'false fails' but can be further tighten-up for smaller field while for larger field found in both H and N and prostate cases, the criteria was correctly applied. Non-uniform distribution of detectors in MapCheck and experience level of planners are two major factors to variation in gamma distribution among clinical cases. This criteria derived from clinical statistics is superior and more accurate than single-valued criteria for lMRT QA acceptance procedure. (author)

  2. Characterization of a prototype MR-compatible Delta4 QA system in a 1.5 tesla MR-linac

    Science.gov (United States)

    de Vries, J. H. W.; Seravalli, E.; Houweling, A. C.; Woodings, S. J.; van Rooij, R.; Wolthaus, J. W. H.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-01-01

    To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (tesla magnetic field of the Elekta MR-linac

  3. TU-A-304-00: Imaging, Treatment Planning, and QA for Stereotactic Body Radiation Therapy (SBRT)

    International Nuclear Information System (INIS)

    2015-01-01

    Increased use of SBRT and hypo fractionation in radiation oncology practice has posted a number of challenges to medical physicist, ranging from planning, image-guided patient setup and on-treatment monitoring, to quality assurance (QA) and dose delivery. This symposium is designed to provide updated knowledge necessary for the safe and efficient implementation of SBRT in various linac platforms, including the emerging digital linacs equipped with high dose rate FFF beams. Issues related to 4D CT, PET and MRI simulations, 3D/4D CBCT guided patient setup, real-time image guidance during SBRT dose delivery using gated/un-gated VMAT or IMRT, and technical advancements in QA of SBRT (in particular, strategies dealing with high dose rate FFF beams) will be addressed. The symposium will help the attendees to gain a comprehensive understanding of the SBRT workflow and facilitate their clinical implementation of the state-of-art imaging and planning techniques. Learning Objectives: Present background knowledge of SBRT, describe essential requirements for safe implementation of SBRT, and discuss issues specific to SBRT treatment planning and QA. Update on the use of multi-dimensional (3D and 4D) and multi-modality (CT, beam-level X-ray imaging, pre- and on-treatment 3D/4D MRI, PET, robotic ultrasound, etc.) for reliable guidance of SBRT. Provide a comprehensive overview of emerging digital linacs and summarize the key geometric and dosimetric features of the new generation of linacs for substantially improved SBRT. Discuss treatment planning and quality assurance issues specific to SBRT. Research grant from Varian Medical Systems

  4. TU-A-304-00: Imaging, Treatment Planning, and QA for Stereotactic Body Radiation Therapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    Increased use of SBRT and hypo fractionation in radiation oncology practice has posted a number of challenges to medical physicist, ranging from planning, image-guided patient setup and on-treatment monitoring, to quality assurance (QA) and dose delivery. This symposium is designed to provide updated knowledge necessary for the safe and efficient implementation of SBRT in various linac platforms, including the emerging digital linacs equipped with high dose rate FFF beams. Issues related to 4D CT, PET and MRI simulations, 3D/4D CBCT guided patient setup, real-time image guidance during SBRT dose delivery using gated/un-gated VMAT or IMRT, and technical advancements in QA of SBRT (in particular, strategies dealing with high dose rate FFF beams) will be addressed. The symposium will help the attendees to gain a comprehensive understanding of the SBRT workflow and facilitate their clinical implementation of the state-of-art imaging and planning techniques. Learning Objectives: Present background knowledge of SBRT, describe essential requirements for safe implementation of SBRT, and discuss issues specific to SBRT treatment planning and QA. Update on the use of multi-dimensional (3D and 4D) and multi-modality (CT, beam-level X-ray imaging, pre- and on-treatment 3D/4D MRI, PET, robotic ultrasound, etc.) for reliable guidance of SBRT. Provide a comprehensive overview of emerging digital linacs and summarize the key geometric and dosimetric features of the new generation of linacs for substantially improved SBRT. Discuss treatment planning and quality assurance issues specific to SBRT. Research grant from Varian Medical Systems.

  5. A multi-institutional survey evaluating patient related QA – phase II

    Directory of Open Access Journals (Sweden)

    Teichmann Tobias

    2017-09-01

    Full Text Available In phase I of the survey a planning intercomparison of patient-related QA was performed at 12 institutions. The participating clinics created phantom based IMRT and VMAT plans which were measured utilizing the ArcCheck diode array. Mobius3D (M3D was used in phase II. It acts as a secondary dose verification tool for patient-specific QA based on average linac beam data collected by Mobius Medical Systems. All Quasimodo linac plans will be analyzed for the continuation of the intercomparison. We aim to determine if Mobius3D is suited for use with diverse treatment techniques, if beam model customization is needed. Initially we computed first Mobius3D results by transferring all plans from phase I to our Mobius3D server. Because of some larger PTV mean dose differences we checked if output factor customization would be beneficial. We performed measurements and output factor correction to account for discrepancies in reference conditions. Compared to Mobius3D's preconfigured average beam data values, these corrected output factors differed by ±1.5% for field sizes between 7x7cm2 and 30x30cm2 and to −3.9% for 3x3cm2. Our method of correcting the output factors turns out good congruence to M3D's reference values for these medium field sizes.

  6. Confocal Microscopy and Flow Cytometry System Performance: Assessment of QA Parameters that affect data Quanitification

    Science.gov (United States)

    Flow and image cytometers can provide useful quantitative fluorescence data. We have devised QA tests to be used on both a flow cytometer and a confocal microscope to assure that the data is accurate, reproducible and precise. Flow Cytometry: We have provided two simple perform...

  7. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.

    Science.gov (United States)

    Mao, Weihua; Speiser, Michael; Medin, Paul; Papiez, Lech; Solberg, Timothy; Xing, Lei

    2011-05-01

    Several linacs with integrated kilovoltage (kV) imaging have been developed for delivery of image guided radiation therapy (IGRT). High geometric accuracy and coincidence of kV imaging systems and megavoltage (MV) beam delivery are essential for successful image guidance. A geometric QA tool has been adapted for routine QA for evaluating and characterizing the geometric accuracy of kV and MV cone-beam imaging systems. The purpose of this work is to demonstrate the application of methodology to routine QA across three IGRT-dedicated linac platforms. It has been applied to a Varian Trilogy (Varian Medical Systems, Palo Alto, CA), an Elekta SynergyS (Elekta, Stockholm, Sweden), and a Brainlab Vero (Brainlab AG, Feldkirchen, Germany). Both the Trilogy and SynergyS linacs are equipped with a retractable kV x-ray tube and a flat panel detector. The Vero utilizes a rotating, rigid ring structure integrating a MV x-ray head mounted on orthogonal gimbals, an electronic portal imaging device (EPID), two kV x-ray tubes, and two fixed flat panel detectors. This dual kV imaging system provides orthogonal radiographs, CBCT images, and real-time fluoroscopic monitoring. Two QA phantoms were built to suit different field sizes. Projection images of a QA phantom were acquired using MV and kV imaging systems at a series of gantry angles. Software developed for this study was used to analyze the projection images and calculate nine geometric parameters for each projection. The Trilogy was characterized five times over one year, while the SynergyS was characterized four times and the Vero once. Over 6500 individual projections were acquired and analyzed. Quantitative geometric parameters of both MV and kV imaging systems, as well as the isocenter consistency of the imaging systems, were successfully evaluated. A geometric tool has been successfully implemented for calibration and QA of integrated kV and MV across a variety of radiotherapy platforms. X-ray source angle deviations up to

  8. A fully electronic intensity-modulated radiation therapy quality assurance (IMRT QA) process implemented in a network comprised of independent treatment planning, record and verify, and delivery systems

    International Nuclear Information System (INIS)

    Bailey, Daniel W; Kumaraswamy, Lalith; Podgorsak, Matthew B

    2010-01-01

    The purpose of this study is to implement an electronic method to perform and analyze intensity-modulated radiation therapy quality assurance (IMRT QA) using an aSi megavoltage electronic portal imaging device in a network comprised of independent treatment planning, record and verify (R&V), and delivery systems. A verification plan was generated in the treatment planning system using the actual treatment plan of a patient. After exporting the treatment fields to the R&V system, the fields were delivered in QA mode with the aSi imager deployed. The resulting dosimetric images are automatically stored in a DICOM-RT format in the delivery system treatment console computer. The relative dose density images are subsequently pushed to the R&V system. The absolute dose images are then transferred electronically from the treatment console computer to the treatment planning system and imported into the verification plan in the dosimetry work space for further analysis. Screen shots of the gamma evaluation and isodose comparison are imported into the R&V system as an electronic file (e.g. PDF) to be reviewed prior to initiation of patient treatment. A relative dose image predicted by the treatment planning system can also be sent to the R&V system to be compared with the relative dose density image measured with the aSi imager. Our department does not have integrated planning, R&V, and delivery systems. In spite of this, we are able to fully implement a paperless and filmless IMRT QA process, allowing subsequent analysis and approval to be more efficient, while the QA document is directly attached to its specific patient chart in the R&V system in electronic form. The calculated and measured relative dose images can be compared electronically within the R&V system to analyze the density differences and ensure proper dose delivery to patients. In the absence of an integrated planning, verifying, and delivery system, we have shown that it is nevertheless possible to develop a

  9. Deep nets vs expert designed features in medical physics: An IMRT QA case study.

    Science.gov (United States)

    Interian, Yannet; Rideout, Vincent; Kearney, Vasant P; Gennatas, Efstathios; Morin, Olivier; Cheung, Joey; Solberg, Timothy; Valdes, Gilmer

    2018-03-30

    The purpose of this study was to compare the performance of Deep Neural Networks against a technique designed by domain experts in the prediction of gamma passing rates for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). A total of 498 IMRT plans across all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam Linacs. Measurements were performed using a commercial 2D diode array, and passing rates for 3%/3 mm local dose/distance-to-agreement (DTA) were recorded. Separately, fluence maps calculated for each plan were used as inputs to a convolution neural network (CNN). The CNNs were trained to predict IMRT QA gamma passing rates using TensorFlow and Keras. A set of model architectures, inspired by the convolutional blocks of the VGG-16 ImageNet model, were constructed and implemented. Synthetic data, created by rotating and translating the fluence maps during training, was created to boost the performance of the CNNs. Dropout, batch normalization, and data augmentation were utilized to help train the model. The performance of the CNNs was compared to a generalized Poisson regression model, previously developed for this application, which used 78 expert designed features. Deep Neural Networks without domain knowledge achieved comparable performance to a baseline system designed by domain experts in the prediction of 3%/3 mm Local gamma passing rates. An ensemble of neural nets resulted in a mean absolute error (MAE) of 0.70 ± 0.05 and the domain expert model resulted in a 0.74 ± 0.06. Convolutional neural networks (CNNs) with transfer learning can predict IMRT QA passing rates by automatically designing features from the fluence maps without human expert supervision. Predictions from CNNs are comparable to a system carefully designed by physicist experts. © 2018 American Association of Physicists in Medicine.

  10. An overview of the QA principles and practices applied to the design, construction, commissioning and bringing into service of an intermediate-level waste encapsulation plant at BNFL Sellafield

    International Nuclear Information System (INIS)

    Lake, M.W.

    1989-01-01

    This paper describes the arrangements adopted by BNFL to ensure that a new ILW Encapsulation Plant Project is brought from project conception through to commercial operation within a QA system which complies with the appropriate standards and includes the following: the role of the QA function within BNFL Engineering; the organization of the commissioning process into a formal QA system to satisfy the requirements of the Nuclear Site License; and the preparatory work carried out by the Site's QA organization in the management of R and D, the selection and evaluation of raw material suppliers, and the bringing together of large numbers of particularly complex activities and differing organizations to provide assurance of quality of the ultimate product. The author presents an explanation of the arrangements adopted by BNFL to monitor the achievements of quality objectives and to ensure a comprehensive audit programme is maintained

  11. A mathematical framework for virtual IMRT QA using machine learning.

    Science.gov (United States)

    Valdes, G; Scheuermann, R; Hung, C Y; Olszanski, A; Bellerive, M; Solberg, T D

    2016-07-01

    It is common practice to perform patient-specific pretreatment verifications to the clinical delivery of IMRT. This process can be time-consuming and not altogether instructive due to the myriad sources that may produce a failing result. The purpose of this study was to develop an algorithm capable of predicting IMRT QA passing rates a priori. From all treatment, 498 IMRT plans sites were planned in eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam Linacs. 3%/3 mm local dose/distance-to-agreement (DTA) was recorded using a commercial 2D diode array. Each plan was characterized by 78 metrics that describe different aspects of their complexity that could lead to disagreements between the calculated and measured dose. A Poisson regression with Lasso regularization was trained to learn the relation between the plan characteristics and each passing rate. Passing rates 3%/3 mm local dose/DTA can be predicted with an error smaller than 3% for all plans analyzed. The most important metrics to describe the passing rates were determined to be the MU factor (MU per Gy), small aperture score, irregularity factor, and fraction of the plan delivered at the corners of a 40 × 40 cm field. The higher the value of these metrics, the worse the passing rates. The Virtual QA process predicts IMRT passing rates with a high likelihood, allows the detection of failures due to setup errors, and it is sensitive enough to detect small differences between matched Linacs.

  12. MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

    Energy Technology Data Exchange (ETDEWEB)

    Zwan, B J [Central Coast Cancer Centre, Gosford, NSW (Australia); University of Newcastle, Newcastle, NSW (Australia); Barnes, M; Greer, P B [University of Newcastle, Newcastle, NSW (Australia); Calvary Mater Hospital, Newcastle, NSW (Australia); Hindmarsh, J; Seymour, E [Central Coast Cancer Centre, Gosford, NSW (Australia); O’Connor, D J [University of Newcastle, Newcastle, NSW (Australia); Keall, P J [University of Sydney, Camperdown, NSW (Australia)

    2016-06-15

    Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for

  13. MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Zwan, B J; Barnes, M; Greer, P B; Hindmarsh, J; Seymour, E; O’Connor, D J; Keall, P J

    2016-01-01

    Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for

  14. The Long and Winding Road: Duties of an NHEERL QA Manager from 1999 to 2008

    Science.gov (United States)

    My career as a US EPA Quality Assurance Manager (QAM) started on September 26, 1999 when I was appointed the QA and Records Manager for the Experimental Toxicology Division (ETD) in NHEERL, in the Office of Research and Development (ORD), on the Research Triangle Campus in RTP, N...

  15. MDEP Common Position CP-VICWG-01. Common Position: Establishment of Common QA/QM Criteria for the Multinational Vendor Inspection CP-VICWG-01

    International Nuclear Information System (INIS)

    2015-01-01

    This document provides a set of common positions for harmonizing inspection criteria called 'Common QA/QM Criteria' which will be used in Multinational Vendor Inspections. This document was prepared by the Vendor Inspection Co-operation Working Group (VICWG) of the Multinational Design Evaluation Program (MDEP). The 'Common QA/QM Criteria' provides the basic areas for consideration when performing Vendor Inspections. The criteria have been developed in conformity with International Codes and Standards such as IAEA, ISO, etc. that MDEP member countries have adopted

  16. NRC [Nuclear Regulatory Commission] perspective of software QA [quality assurance] in the nuclear history

    International Nuclear Information System (INIS)

    Weiss, S.H.

    1988-01-01

    Computer technology has been a part of the nuclear industry since its inception. However, it is only recently that computers have been integrated into reactor operations. During the early history of commercial nuclear power in the United States, the US Nuclear Regulatory Commission (NRC) discouraged the use of digital computers for real-time control and monitoring of nuclear power plant operation. At the time, this position was justified since software engineering was in its infancy, and horror stories on computer crashes were plentiful. Since the advent of microprocessors and inexpensive computer memories, significant advances have been made in fault-tolerant computer architecture that have resulted in highly reliable, durable computer systems. The NRC's requirement for safety parameter display system (SPDS) stemmed form the results of studies and investigations conducted on the Three Mile Island Unit 2 (TMI-2) accident. An NRC contractor has prepared a handbook of software QA techniques applicable to the nuclear industry, published as NUREG/CR-4640 in August 1987. Currently, the NRC is considering development of an inspection program covering software QA. Future efforts may address verification and validation as applied to expert systems and artificial intelligence programs

  17. 76 FR 5832 - International Business Machines (IBM), Software Group Business Unit, Optim Data Studio Tools QA...

    Science.gov (United States)

    2011-02-02

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,554] International Business Machines (IBM), Software Group Business Unit, Optim Data Studio Tools QA, San Jose, CA; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated November 29, 2010, a worker and a state workforce official...

  18. Sirr al-khalīqa and its influence in the Arabic and Persianate world: ‘Awn b. al-Mundhir’s commentary and its unknown Persian translation

    Directory of Open Access Journals (Sweden)

    Mohammad Karimi Zanjani Asl

    2017-03-01

    Full Text Available In the Islamic period, Apollonius of Tyana (c. 15-100 CE was well known both as “Lord of the Talismans” (ṣāḥib al-ṭilasmāt and as a Neo-Pythagorean-Hermetic philosopher. In his Kitāb al-Aḥjār, Jābir b. Ḥayyān cites “the Muslim advocates of Apollonius” (aṣḥāb Balīnās al-Islāmīyūn. The reference shows that Apollonius’ most prominent work, Sirr alkhalīqa, was already famous in the Arabicspeaking world from very early on. This article gives an overview of citations of Apollonius in Islamic sources from different fields and of the works generally attributed to him. Furthermore, I review Sirr al-khalīqa, its influences on the Jābirian works and its reception in the Ismā‘īlī tradition. This article additionally discusses an Arabic commentary of Sirr al-khalīqa by ‘Awn b. al-Mundhir (4th/10th century, which is extant in a unique manuscript, and its hitherto unknown Persian translation. This Persian translation covers parts of Ibn al-Mundhir’s work not available in the Arabic excerpt and is therefore an important source for the history of Islamic alchemy. An edition of the Persian translation is given as an appendix.

  19. SU-F-T-569: Implementation of a Patient Specific QA Method Using EBT-XD for CyberKnife SRS/SBRT Plans

    Energy Technology Data Exchange (ETDEWEB)

    Zerouali, K; Aubry, J; Doucet, R [Centre hospitalier de l’Universite de Montreal, Montreal, Quebec (Canada)

    2016-06-15

    Purpose: To implement the new EBT-XD Gafchromic films for accurate dosimetric and geometric validation of stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) CyberKnife (CK) patient specific QA. Methods: Film calibration was performed using a triplechannel film analysis on an Epson 10000XL scanner. Calibration films were irradiated using a Varian Clinac 21EX flattened beam (0 to 20 Gy), to ensure sufficient dose homogeneity. Films were scanned to a resolution of 0.3 mm, 24 hours post irradiation following a well-defined protocol. A set of 12 QA was performed for several types of CK plans: trigeminal neuralgia, brain metastasis, prostate and lung tumors. A custom made insert for the CK head phantom has been manufactured to yield an accurate measured to calculated dose registration. When the high dose region was large enough, absolute dose was also measured with an ionization chamber. Dose calculation is performed using MultiPlan Ray-tracing algorithm for all cases since the phantom is mostly made from near water-equivalent plastic. Results: Good agreement (<2%) was found between the dose to the chamber and the film, when a chamber measurement was possible The average dose difference and standard deviations between film measurements and TPS calculations were respectively 1.75% and 3%. The geometric accuracy has been estimated to be <1 mm, combining robot positioning uncertainty and film registration to calculated dose. Conclusion: Patient specific QA measurements using EBT-XD films yielded a full 2D dose plane with high spatial resolution and acceptable dose accuracy. This method is particularly promising for trigeminal neuralgia plan QA, where the positioning of the spatial dose distribution is equally or more important than the absolute delivered dose to achieve clinical goals.

  20. Pathways into Teaching: Q&A with Dr. Pam Grossman. REL Mid-Atlantic Teacher Effectiveness Webinar Series

    Science.gov (United States)

    Regional Educational Laboratory Mid-Atlantic, 2013

    2013-01-01

    This webinar explored several elements of teacher preparation pathways, including the history, popularity, and quality of various routes to certification, as well as the impact of these various pathways on teacher quality and retention and student achievement. This Q&A addressed the questions participants had for Dr. Grossman following the…

  1. Human Leucocyte Antigen-G (HLA-G and Its Murine Functional Homolog Qa2 in the Trypanosoma cruzi Infection

    Directory of Open Access Journals (Sweden)

    Fabrício C. Dias

    2015-01-01

    Full Text Available Genetic susceptibility factors, parasite strain, and an adequate modulation of the immune system seem to be crucial for disease progression after Trypanosoma cruzi infection. HLA-G and its murine functional homolog Qa2 have well-recognized immunomodulatory properties. We evaluated the HLA-G 3′ untranslated region (3′UTR polymorphic sites (associated with mRNA stability and target for microRNA binding and HLA-G tissue expression (heart, colon, and esophagus in patients presenting Chagas disease, stratified according to the major clinical variants. Further, we investigated the transcriptional levels of Qa2 and other pro- and anti-inflammatory genes in affected mouse tissues during T. cruzi experimental acute and early chronic infection induced by the CL strain. Chagas disease patients exhibited differential HLA-G 3′UTR susceptibility allele/genotype/haplotype patterns, according to the major clinical variant (digestive/cardiac/mixed/indeterminate. HLA-G constitutive expression on cardiac muscle and colonic cells was decreased in Chagasic tissues; however, no difference was observed for Chagasic and non-Chagasic esophagus tissues. The transcriptional levels of Qa2 and other anti and proinflammatory (CTLA-4, PDCD1, IL-10, INF-γ, and NOS-2 genes were induced only during the acute T. cruzi infection in BALB/c and C57BL/6 mice. We present several lines of evidence indicating the role of immunomodulatory genes and molecules in human and experimental T. cruzi infection.

  2. Clinical validation of an in-house EPID dosimetry system for IMRT QA at the Prince of Wales Hospital

    Science.gov (United States)

    Tyler, M.; Vial, P.; Metcalfe, P.; Downes, S.

    2013-06-01

    In this study a simple method using standard flood-field corrected Electronic Portal Imaging Device (EPID) images for routine Intensity Modulated Radiation Therapy (IMRT) Quality Assurance (QA) was investigated. The EPID QA system was designed and tested on a Siemens Oncor Impression linear accelerator with an OptiVue 1000ST EPID panel (Siemens Medical Solutions USA, Inc, USA) and an Elekta Axesse linear accelerator with an iViewGT EPID (Elekta AB, Sweden) for 6 and 10 MV IMRT fields with Step-and-Shoot and dynamic-MLC delivery. Two different planning systems were used for patient IMRT field generation for comparison with the measured EPID fluences. All measured IMRT plans had >95% agreement to the planning fluences (using 3 cGy / 3 mm Gamma Criteria) and were comparable to the pass-rates calculated using a 2-D diode array dosimeter.

  3. Steinberg ``AUDIOMAPS'' Music Appreciation-Via-Understanding: Special-Relativity + Expectations ``Quantum-Theory'': a Quantum-ACOUSTO/MUSICO-Dynamics (QA/MD)

    Science.gov (United States)

    Fender, Lee; Steinberg, Russell; Siegel, Edward Carl-Ludwig

    2011-03-01

    Steinberg wildly popular "AUDIOMAPS" music enjoyment/appreciation-via-understanding methodology, versus art, music-dynamics evolves, telling a story in (3+1)-dimensions: trails, frames, timbres, + dynamics amplitude vs. music-score time-series (formal-inverse power-spectrum) surprisingly closely parallels (3+1)-dimensional Einstein(1905) special-relativity "+" (with its enjoyment-expectations) a manifestation of quantum-theory expectation-values, together a music quantum-ACOUSTO/MUSICO-dynamics(QA/MD). Analysis via Derrida deconstruction enabled Siegel-Baez "Category-Semantics" "FUZZYICS"="CATEGORYICS ('TRIZ") Aristotle SoO DEduction , irrespective of Boon-Klimontovich vs. Voss-Clark[PRL(77)] music power-spectrum analysis sampling-time/duration controversy: part versus whole, shows QA/MD reigns supreme as THE music appreciation-via-analysis tool for the listener in musicology!!! Connection to Deutsch-Hartmann-Levitin[This is Your Brain on Music, (06)] brain/mind-barrier brain/mind-music connection is subtle/compelling/immediate!!!

  4. Clinical validation of an in-house EPID dosimetry system for IMRT QA at the Prince of Wales Hospital

    International Nuclear Information System (INIS)

    Tyler, M; Downes, S; Vial, P; Metcalfe, P

    2013-01-01

    In this study a simple method using standard flood-field corrected Electronic Portal Imaging Device (EPID) images for routine Intensity Modulated Radiation Therapy (IMRT) Quality Assurance (QA) was investigated. The EPID QA system was designed and tested on a Siemens Oncor Impression linear accelerator with an OptiVue 1000ST EPID panel (Siemens Medical Solutions USA, Inc, USA) and an Elekta Axesse linear accelerator with an iViewGT EPID (Elekta AB, Sweden) for 6 and 10 MV IMRT fields with Step-and-Shoot and dynamic-MLC delivery. Two different planning systems were used for patient IMRT field generation for comparison with the measured EPID fluences. All measured IMRT plans had >95% agreement to the planning fluences (using 3 cGy / 3 mm Gamma Criteria) and were comparable to the pass-rates calculated using a 2-D diode array dosimeter.

  5. Steinberg ``AUDIOMAPS" Music Appreciation-Via-Understanding: Special-Relativity + Expectations "Quantum-Theory": a Quantum-ACOUSTO/MUSICO-Dynamics (QA/MD)

    Science.gov (United States)

    Steinberg, R.; Siegel, E.

    2010-03-01

    ``AUDIOMAPS'' music enjoyment/appreciation-via-understanding methodology, versus art, music-dynamics evolves, telling a story in (3+1)-dimensions: trails, frames, timbres, + dynamics amplitude vs. music-score time-series (formal-inverse power- spectrum) surprisingly closely parallels (3+1)-dimensional Einstein(1905) special-relativity ``+'' (with its enjoyment- expectations) a manifestation of quantum-theory expectation- values, together a music quantum-ACOUSTO/MUSICO-dynamics (QA/MD). Analysis via Derrida deconstruction enabled Siegel- Baez ``Category-Semantics'' ``FUZZYICS''=``CATEGORYICS (``SON of 'TRIZ") classic Aristotle ``Square-of-Opposition" (SoO) DEduction-logic, irrespective of Boon-Klimontovich versus Voss- Clark[PRL(77)] music power-spectrum analysis sampling- time/duration controversy: part versus whole, shows that ``AUDIOMAPS" QA/MD reigns supreme as THE music appreciation-via- analysis tool for the listener in musicology!!! Connection to Deutsch-Hartmann-Levitin[This is Your Brain on Music,(2006)] brain/mind-barrier brain/mind-music connection is both subtle and compelling and immediate!!!

  6. The Game is aFoot, Watson: DeepQA systems and the future of HCI

    OpenAIRE

    Keates, Simeon; Varker, Philip

    2012-01-01

    In February 2011, the IBM Watson DeepQA (deep question and answer) system took part in a special challenge, pitting its question and answer capability against former Jeopardy!TM grand champions in a televised match. Watson emerged victorious from the challenge, demonstrating that current question answering technology has advanced to the point where it can arguably be more dependable than human experts. This new system represents a significant breakthrough in humanity’s decades-long endeavour ...

  7. Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, Michael, E-mail: mdumas1127@gmail.com [Department of Radiation Oncology, Wayne State University School of Medicine and Karmanos Cancer Institute Detroit, Detroit, Michigan 48201 and Department of Radiation Oncology, Henry Ford Hospital, Detroit, Michigan 48202 (United States); Rakowski, Joseph T. [Department of Radiation Oncology, Wayne State University School of Medicine and Karmanos Cancer Institute Detroit, Detroit, Michigan 48201 (United States)

    2015-12-15

    Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner

  8. WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

    International Nuclear Information System (INIS)

    Gersh, J

    2015-01-01

    Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts

  9. SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, N [University of Miami, Miami, FL (United States); Denissova, S [Sylvester Comprehensive Cancer Center Deerfield, Weston, FL (United States)

    2016-06-15

    Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% to 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.

  10. A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA

    Science.gov (United States)

    Alhazmi, Abdulaziz; Gianoli, Chiara; Neppl, Sebastian; Martins, Juliana; Veloza, Stella; Podesta, Mark; Verhaegen, Frank; Reiner, Michael; Belka, Claus; Parodi, Katia

    2018-06-01

    Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are relatively complex treatment delivery techniques and require quality assurance (QA) procedures. Pre-treatment dosimetric verification represents a fundamental QA procedure in daily clinical routine in radiation therapy. The purpose of this study is to develop an EPID-based approach to reconstruct a 3D dose distribution as imparted to a virtual cylindrical water phantom to be used for plan-specific pre-treatment dosimetric verification for IMRT and VMAT plans. For each depth, the planar 2D dose distributions acquired in air were back-projected and convolved by depth-specific scatter and attenuation kernels. The kernels were obtained by making use of scatter and attenuation models to iteratively estimate the parameters from a set of reference measurements. The derived parameters served as a look-up table for reconstruction of arbitrary measurements. The summation of the reconstructed 3D dose distributions resulted in the integrated 3D dose distribution of the treatment delivery. The accuracy of the proposed approach was validated in clinical IMRT and VMAT plans by means of gamma evaluation, comparing the reconstructed 3D dose distributions with Octavius measurement. The comparison was carried out using (3%, 3 mm) criteria scoring 99% and 96% passing rates for IMRT and VMAT, respectively. An accuracy comparable to the one of the commercial device for 3D volumetric dosimetry was demonstrated. In addition, five IMRT and five VMAT were validated against the 3D dose calculation performed by the TPS in a water phantom using the same passing rate criteria. The median passing rates within the ten treatment plans was 97.3%, whereas the lowest was 95%. Besides, the reconstructed 3D distribution is obtained without predictions relying on forward dose calculation and without external phantom or dosimetric devices. Thus, the approach provides a fully automated, fast and easy QA

  11. WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

    Energy Technology Data Exchange (ETDEWEB)

    Gersh, J [Gibbs Cancer Center and Research Institute - Pelham, Greer, SC (United States); Spectrum Medical Physics, LLC, Greenville, SC (United States)

    2015-06-15

    Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts

  12. CTC Sentinel. Volume 2, Issue 1, January 2009. Al-Qa’ida’s Five Aspects of Power

    Science.gov (United States)

    2009-01-01

    strategic messaging efforts—the conduit for brand awareness and the expansion of the movement. The distributed social movement that is al-Qa`ida is multi...far beyond message projection and brand awareness efforts. Indeed, the efforts to segment its audience have enabled a far more nuanced messaging

  13. Guide for reviewing safety analysis reports for packaging: Review of quality assurance requirements

    International Nuclear Information System (INIS)

    Moon, D.W.

    1988-10-01

    This review section describes quality assurance requirements applying to design, purchase, fabrication, handling, shipping, storing, cleaning, assembly, inspection, testing, operation, maintenance, repair, and modification of components of packaging which are important to safety. The design effort, operation's plans, and quality assurance requirements should be integrated to achieve a system in which the independent QA program is not overly stringent and the application of QA requirements is commensurate with safety significance. The reviewer must verify that the applicant's QA section in the SARP contains package-specific QA information required by DOE Orders and federal regulations that demonstrate compliance. 8 refs

  14. Quality assurance (QA) for operations of fusion machines as applied to the tandem mirror experiment upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Chargin, A.K.; Damm, C.C.; Turner, W.C.

    1983-01-01

    Even the best QA plan and its successful execution during construction of a typical fusion machine will produce hardware that is inoperative for some fraction of time. Operating a machine with its hardware out of tolerance, with respect to the specifications, does produce data which is the goal of the experiment. However, a majority of such data are difficult to interpret and may not contribute to understanding the behavior of the experiment. In addition, few fusion machines just operate. The majority of the machines are in the process of being rebuilt and/or added to as they operate. These modifications can keep an otherwise operational machine from running. To insure quality in operation of TMX-U, the authors employ a series of QA procedures. They start with technical milestones, schedules, and budgets that are all negotiated with DOE. Within that framework they implement a total management scheme which, in addition to normal schedule and budget controls, includes: detailed experimental run plans, definition of machine configuration required to accomplish the run plan, subsystem work-ups, instrument calibration, verification of subsystem operation, and repetition of standard physics plasma parameters. All of these activities must be completed before taking data for the experimental run plan. If a subsystem is found out of tolerance, a decision must be made either to delay operation and fix the problem or to continue on a contingency-run plan which should still produce the data relevant to the project milestones. In this presentation those QA procedures for TMX-U operations that are applied to minimize the cost and time required to achieve the technical objectives are discussed

  15. Evaluation of MotionSim XY/4D for patient specific QA of respiratory gated treatment for lung cancer

    International Nuclear Information System (INIS)

    Wen, C.; Ackerly, T.; Lancaster, C.; Bailey, N.

    2011-01-01

    Full text: A commercial system-MotionSim XY/4D(TM) capable of simulating two-dimensional tumour motion and measuring planar dose with diode-matrix was evaluated at the Alfred Hospital, for establishing patient-specific QA programme of respiratory gated treatment of lung cancer. This study presents the investigation of accuracies, limitations and the practical aspects of that system. Planar doses generated on iPlan-TM by mapping clinical beams to a scanned-in water phantom were measured by MotionSim XY/4D-TM with 5 cm water equivalent build-up at normal incidence. The gated delivery using ExacTrac-TM through tracking infrared markers simulating external respiration surrogate was measured simultaneously with Gaf-ChromicR RTQA2 film and MapCHECK 2TM . Dose maps of both non-gated and gated beams with 30% duty cycle were compared with both film and diodes measurements. Differences in dose distribution were analysed with built-in tools in MapCHECK2 TM and the effect of residual motion within the beamenabled window was then assessed. Preliminary results indicate that difference between Gafchromic film and MapCHECK2 measurements of same beam was ignorable. Gated dose delivery to a target at 9 mm maximum motion was in good agreement with planned dose. Complement to measurements suggested in AAPM Report No.9 I I, this QA device can detect any random error and assess the magnitude of residual target motion through analysing differences between planned and delivered doses as gamma function. Although some user-friendliness aspects could be improved, it meets its specification and can be used for routine clinical QA purposes provided calibrations were performed and procedures were followed.

  16. Spray nozzle pattern test for the DWPF HEME Task QA Plan

    International Nuclear Information System (INIS)

    Lee, L.

    1991-01-01

    The DWPF melter off-gas systems have two High Efficiency Mist Eliminators (HEME) upstream of the High-Efficiency Particulates Air filters (HEPA) to remove fine mists and particulates from the off-gas. To have an acceptable filter life and an efficient operation, an air atomized water is spray on the HEME. The water spray keeps the HEME wet and dissolves the soluble particulates and enhances and HEME efficiency. DWPF Technical asked SRL to determine the conditions which will give satisfactory atomization and distribution of water so that the HEME will operate efficiently. The purpose of this document is to identify, QA controls to be applied in the pursuit of this task (WSRC-RP-91-1151)

  17. Dynamic wedge, electron energy and beam profile Q.A. using an ionization chamber linear array

    International Nuclear Information System (INIS)

    Kenny, M.B.; Todd, S.P.

    1996-01-01

    Since the introduction of multi-modal linacs the quality assurance workload of a Physical Sciences department has increased dramatically. The advent of dynamic wedges has further complicated matters because of the need to invent accurate methods to perform Q.A. in a reasonable time. We have been using an ionization chamber linear array, the Thebes 7000 TM by Victoreen, Inc., for some years to measure X-ray and electron beam profiles. Two years ago we developed software to perform Q.A. on our dynamic wedges using the array and more recently included a routine to check electron beam energies using the method described by Rosenow, U.F. et al., Med. Phys. 18(1) 19-25. The integrated beam and profile management system has enabled us to maintain a comprehensive quality assurance programme on all our linaccs. Both our efficiency and accuracy have increased to the point where we are able to keep up with the greater number of tests required without an increase in staff or hours spent in quality assurance. In changing the processor from the Z80 of the Thebes console to the 486 of the PC we have also noticed a marked increase in the calibration stability of the array. (author)

  18. SU-D-213-04: Accounting for Volume Averaging and Material Composition Effects in An Ionization Chamber Array for Patient Specific QA

    International Nuclear Information System (INIS)

    Fugal, M; McDonald, D; Jacqmin, D; Koch, N; Ellis, A; Peng, J; Ashenafi, M; Vanek, K

    2015-01-01

    Purpose: This study explores novel methods to address two significant challenges affecting measurement of patient-specific quality assurance (QA) with IBA’s Matrixx Evolution™ ionization chamber array. First, dose calculation algorithms often struggle to accurately determine dose to the chamber array due to CT artifact and algorithm limitations. Second, finite chamber size and volume averaging effects cause additional deviation from the calculated dose. Methods: QA measurements were taken with the Matrixx positioned on the treatment table in a solid-water Multi-Cube™ phantom. To reduce the effect of CT artifact, the Matrixx CT image set was masked with appropriate materials and densities. Individual ionization chambers were masked as air, while the high-z electronic backplane and remaining solid-water material were masked as aluminum and water, respectively. Dose calculation was done using Varian’s Acuros XB™ (V11) algorithm, which is capable of predicting dose more accurately in non-biologic materials due to its consideration of each material’s atomic properties. Finally, the exported TPS dose was processed using an in-house algorithm (MATLAB) to assign the volume averaged TPS dose to each element of a corresponding 2-D matrix. This matrix was used for comparison with the measured dose. Square fields at regularly-spaced gantry angles, as well as selected patient plans were analyzed. Results: Analyzed plans showed improved agreement, with the average gamma passing rate increasing from 94 to 98%. Correction factors necessary for chamber angular dependence were reduced by 67% compared to factors measured previously, indicating that previously measured factors corrected for dose calculation errors in addition to true chamber angular dependence. Conclusion: By comparing volume averaged dose, calculated with a capable dose engine, on a phantom masked with correct materials and densities, QA results obtained with the Matrixx Evolution™ can be significantly

  19. Regulation of primary cytotoxic T lymphocyte responses generated during mixed leukocyte culture with H-2d identical Qa-1-disparate cells

    International Nuclear Information System (INIS)

    Huston, D.P.; Tavana, G.; Rich, R.R.; Gressens, S.E.

    1986-01-01

    Cytotoxic lymphocyte (CTL) responses are not usually generated during primary mixed leukocyte culture (MLC) with H-2 identical cells. Thus NZB mice are unusual in that their spleen cells do mount CTL responses during primary MLC with H-2d identical stimulator cells; the predominant target antigen for these NZB responses is Qa-1b. Considering the numerous immunoregulatory defects in NZB mice, we postulated that these NZB anti-Qa-1 primary CTL responses were due to an abnormality in T suppressor cell activity. Cellular interactions capable of suppressing NZB anti-Qa-1 primary CTL responses were investigated by using one-way and two-way MLC with spleen cells from NZB mice and other H-2d strains. Although H-2d identical one-way MLC with the use of NZB responders resulted in substantial CTL responses, only minimal CTL responses were detected from two-way MLC with the use of NZB spleen cells plus nonirradiated spleen cells from other H-2d mice. Thus the presence of non-NZB spleen cells in the two-way H-2d identical MLC prevented the generation of NZB CTL. Noncytotoxic mechanisms were implicated in the suppression of the NZB CTL responses during two-way MLC, because only minimal CTL activity was generated when NZB spleen cells were cultured with semiallogeneic, H-2d identical (e.g., NZB X BALB) F1 spleen cells. The observed suppression could be abrogated with as little as 100 rad gamma-irradiation to the non-NZB spleen cells. The phenotype of these highly radiosensitive spleen cells was Thy-1+, Lyt-1+, Lyt-2-, L3T4+. The functional presence of these cells in the spleens of semiallogeneic, H-2d identical F1 mice indicated that their deficiency in NZB mice was a recessive trait. These data suggest that NZB mice lack an L3T4+ cell present in the spleens of normal mice that is capable of suppressing primary anti-Qa-1 CTL responses

  20. Beware of Imitators: Al-Qa’ida through the Lens of its Confidential Secretary

    Science.gov (United States)

    2012-06-04

    describe al-Qa`ida’s ideology are distortions which follow typologies devised by the West.45 He rejects all labels, such as “Wahhabis,” “salafi...political or economic target, resulting in the death of 19 people: 14 German tourists ; a French citizen; and four Tunisians.74 In addition, Harun lists...decision-making. He disagrees with the attacks against tourists in July 2007,99 deeming them to be fruitless in so far as serving the causes of the umma

  1. Creating and Sustaining Professional Learning Communities: Q&A with Stephanie Hirsh, Ph.D. 2016 Educator Effectiveness Webinar Series

    Science.gov (United States)

    Regional Educational Laboratory Mid-Atlantic, 2016

    2016-01-01

    In this webinar, Dr. Stephanie Hirsh, Executive Director of Learning Forward, presented the research on effective PLCs and shared her experiences in creating, assessing, and leading PLCs. This Q&A addressed questions participants had for Dr. Hirsh following the webinar. The webinar recording and PowerPoint presentation are also available.

  2. Advances in Automated QA/QC for TRISO Fuel Particle Production

    International Nuclear Information System (INIS)

    Hockey, Ronald L.; Bond, Leonard J.; Batishko, Charles R.; Gray, Joseph N.; Saurwein, John J.; Lowden, Richard A.

    2004-01-01

    Fuel in most Generation IV reactor designs typically encompasses billions of the TRISO particles. Present day QA/QC methods, done manually and in many cases destructively, cannot economically test a statistically significant fraction of the large number of the individual fuel particles required. Fully automated inspection technologies are essential to economical TRISO fuel particle production. A combination of in-line nondestructive (NDE) measurements employing electromagnetic induction and digital optical imaging analysis is currently under investigation and preliminary data indicate the potential for meeting the demands of this application. To calibrate high-speed NDE methods, surrogate fuel particle samples are being coated with layers containing a wide array of defect types found to degrade fuel performance and these are being characterized via high-resolution CT and digital radiographic images

  3. MO-FG-CAMPUS-TeP1-01: An Efficient Method of 3D Patient Dose Reconstruction Based On EPID Measurements for Pre-Treatment Patient Specific QA

    Energy Technology Data Exchange (ETDEWEB)

    David, R; Lee, C [Central Coast Cancer Centre, Gosford, NSW (Australia); Calvary Mater Newcastle, Newcastle (Australia); Zwan, B; Hindmarsh, J; Seymour, E; Kandasamy, K; Arthur, G [Central Coast Cancer Centre, Gosford, NSW (Australia); Greer, P [Calvary Mater Newcastle, Newcastle (Australia); University of Newcastle, Newcastle, NSW (Australia)

    2016-06-15

    Purpose: To demonstrate an efficient and clinically relevant patient specific QA method by reconstructing 3D patient dose from 2D EPID images for IMRT plans. Also to determine the usefulness of 2D QA metrics when assessing 3D patient dose deviations. Methods: Using the method developed by King et al (Med Phys 39(5),2839–2847), EPID images of IMRT fields were acquired in air and converted to dose at 10 cm depth (SAD setup) in a flat virtual water phantom. Each EPID measured dose map was then divided by the corresponding treatment planning system (TPS) dose map calculated with an identical setup, to derive a 2D “error matrix”. For each field, the error matrix was used to adjust the doses along the respective ray lines in the original patient 3D dose. All field doses were combined to derive a reconstructed 3D patient dose for quantitative analysis. A software tool was developed to efficiently implement the entire process and was tested with a variety of IMRT plans for 2D (virtual flat phantom) and 3D (in-patient) QA analysis. Results: The method was tested on 60 IMRT plans. The mean (± standard deviation) 2D gamma (2%,2mm) pass rate (2D-GPR) was 97.4±3.0% and the mean 2D gamma index (2D-GI) was 0.35±0.06. The 3D PTV mean dose deviation was 1.8±0.8%. The analysis showed very weak correlations between both the 2D-GPR and 2D-GI when compared with PTV mean dose deviations (R2=0.3561 and 0.3632 respectively). Conclusion: Our method efficiently calculates 3D patient dose from 2D EPID images, utilising all of the advantages of an EPID-based dosimetry system. In this study, the 2D QA metrics did not predict the 3D patient dose deviation. This tool allows reporting of the 3D volumetric dose parameters thus providing more clinically relevant patient specific QA.

  4. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  5. Characterisation of flattening filter free (FFF) beam properties for initial beam set-up and routine QA, independent of flattened beams

    Science.gov (United States)

    Paynter, D.; Weston, S. J.; Cosgrove, V. P.; Thwaites, D. I.

    2018-01-01

    Flattening filter free (FFF) beams have reached widespread use for clinical treatment deliveries. The usual methods for FFF beam characterisation for their quality assurance (QA) require the use of associated conventional flattened beams (cFF). Methods for QA of FFF without the need to use associated cFF beams are presented and evaluated against current methods for both FFF and cFF beams. Inflection point normalisation is evaluated against conventional methods for the determination of field size and penumbra for field sizes from 3 cm  ×  3 cm to 40 cm  ×  40cm at depths from dmax to 20 cm in water for matched and unmatched FFF beams and for cFF beams. A method for measuring symmetry in the cross plane direction is suggested and evaluated as FFF beams are insensitive to symmetry changes in this direction. Methods for characterising beam energy are evaluated and the impact of beam energy on profile shape compared to that of cFF beams. In-plane symmetry can be measured, as can cFF beams, using observed changes in profile, whereas cross-plane symmetry can be measured by acquiring profiles at collimator angles 0 and 180. Beam energy and ‘unflatness’ can be measured as with cFF beams from observed shifts in profile with changing beam energy. Normalising the inflection points of FFF beams to 55% results in an equivalent penumbra and field size measurement within 0.5 mm of conventional methods with the exception of 40 cm  ×  40 cm fields at a depth of 20 cm. New proposed methods are presented that make it possible to independently carry out set up and QA measurements on beam energy, flatness, symmetry and field size of an FFF beam without the need to reference to an equivalent flattened beam of the same energy. The methods proposed can also be used to carry out this QA for flattened beams, resulting in universal definitions and methods for MV beams. This is presented for beams produced by an Elekta linear accelerator, but is

  6. PGDP [Paducah Gaseous Diffusion Plant]-UF6 handling, sampling, analysis and associated QC/QA and safety related procedures

    International Nuclear Information System (INIS)

    Harris, R.L.

    1987-01-01

    This document is a compilation of Paducah Gaseous Diffusion Plant procedures on UF 6 handling, sampling, and analysis, along with associated QC/QA and safety related procedures. It was assembled for transmission by the US Department of Energy to the Korean Advanced Energy Institute as a part of the US-Korea technical exchange program

  7. QA lessons learned for parameter control from the WIPP Project

    International Nuclear Information System (INIS)

    Richards, R.R.

    1998-01-01

    This paper provides a summary of lessons learned from experiences on the Waste Isolation Pilot Plant (WJPP) Project in implementation of quality assurance controls surrounding inputs for performance assessment analysis. Since the performance assessment (PA) process is inherent in compliance determination for any waste repository, these lessons-learned are intended to be useful to investigators, analysts, and Quality Assurance (QA) practitioners working on high level waste disposal projects. On the WIPP Project, PA analyses for regulatory-compliance determination utilized several inter-related computer programs (codes) that mathematically modeled phenomena such as radionuclide release, retardation, and transport. The input information for those codes are the parameters that are the subject of this paper. Parameters were maintained in a computer database, which was then queried electronically by the PA codes whenever input was needed as the analyses were run

  8. Quality assurance (QA) training at Westinghouse including innovative approaches for achieving an effective QA programme and establishing constructive interaction

    International Nuclear Information System (INIS)

    Chivers, J.H.; Scanga, B.E.

    1982-01-01

    Experience of the Westinghouse Water Reactors Division with indoctrination and training of quality engineers includes training of personnel from Westinghouse divisions in the USA and overseas as well as of customers' personnel. A written plan is prepared for each trainee in order to fit the training to the individual's needs, and to cover the full range of information and activities. The trainee is also given work assignments, working closely with experienced quality engineers. He may prepare inspection plans and audit check lists, assist in the preparation of QA training modules, write procedures, and perform supplier surveillance and data analyses, or make special studies of operating systems. The trainee attends seminars and special courses on work-related technical subjects. Throughout the training period, emphasis is placed on inculcating an attitude of team work in the trainee so that the result of the training is the achievement of both quality and productivity. Certification is extended (given that education/experience/skill requirements are met) to such functions as mechanical equipment quality engineering, electrical equipment quality engineering, and start-up and testing quality engineering. A well-trained quality engineer is equipped to provide technical assistance to other disciplines and, through effective co-operation with others, contributes to the success of the organization's endeavours. (author)

  9. The Teacher's Role in Quality Classroom Interactions: Q&A with Dr. Drew Gitomer. REL Mid-Atlantic Teacher Effectiveness Webinar Series

    Science.gov (United States)

    Regional Educational Laboratory Mid-Atlantic, 2013

    2013-01-01

    In this webinar, Dr. Drew Gitomer, professor at Rutgers University, shared results from recent studies of classroom observations that helped participants understand both general findings about the qualities of classroom interactions and also the challenges to carrying out valid and reliable observations. This Q&A addressed the questions…

  10. QA for helical tomotherapy: Report of the AAPM Task Group 148

    Energy Technology Data Exchange (ETDEWEB)

    Langen, Katja M.; Papanikolaou, Niko; Balog, John; Crilly, Richard; Followill, David; Goddu, S. Murty; Grant, Walter III; Olivera, Gustavo; Ramsey, Chester R.; Shi Chengyu [Department of Radiation Oncology, M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); Department of Radiation Oncology, Cancer Therapy and Research Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States); Mohawk Valley Medical Physics, Rome, New York 13440 (United States); Department of Radiation Medicine, Oregon Health and Science University, Portland, Oregon 97239 (United States); Section of Outreach Physics, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Department of Radiology/Section of Radiation Oncology, Baylor College of Medicine, Methodist Hospital, Houston, Texas 77030 (United States); TomoTherapy, Inc., Madison, Wisconsin 53717 and Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States); Thompson Cancer Survival Center, Knoxville, Tennessee 37916 (United States); Department of Radiation Oncology, Cancer Therapy and Research Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States)

    2010-09-15

    Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of Physicists in Medicine commissioned Task Group 148 to review this modality and make recommendations for quality assurance related methodologies. The specific objectives of this Task Group are: (a) To discuss quality assurance techniques, frequencies, and tolerances and (b) discuss dosimetric verification techniques applicable to this unit. This report summarizes the findings of the Task Group and aims to provide the practicing clinical medical physicist with the insight into the technology that is necessary to establish an independent and comprehensive quality assurance program for a helical tomotherapy unit. The emphasis of the report is to describe the rationale for the proposed QA program and to provide example tests that can be performed, drawing from the collective experience of the task group members and the published literature. It is expected that as technology continues to evolve, so will the test procedures that may be used in the future to perform comprehensive quality assurance for helical tomotherapy units.

  11. SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y [University of Kansas Hospital, Kansas City, KS (United States); Fullerton, G; Goins, B [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States)

    2015-06-15

    Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement

  12. An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position

    International Nuclear Information System (INIS)

    Rosca, Florin; Lorenz, Friedlieb; Hacker, Fred L.; Chin, Lee M.; Ramakrishna, Naren; Zygmanski, Piotr

    2006-01-01

    We have designed and implemented a new stereotactic linac QA test with stereotactic precision. The test is used to characterize gantry sag, couch wobble, cone placement, MLC offsets, and room lasers' positions relative to the radiation isocenter. Two MLC star patterns, a cone pattern, and the laser line patterns are recorded on the same imaging medium. Phosphor plates are used as imaging medium due to their sensitivity to red light. The red light of room lasers erases some of the irradiation information stored on the phosphor plates enabling accurate and direct measurements for the position of room lasers and radiation isocenter. Using film instead of the phosphor plate as imaging medium is possible, however, it is less practical. The QA method consists of irradiating four phosphor plates that record the gantry sag between the 0 deg.and 180 deg.gantry angles, the position and stability of couch rotational axis, the sag between the 90 deg.and 270 deg.gantry angles, the accuracy of cone placement on the collimator, the MLC offsets from the collimator rotational axis, and the position of laser lines relative to the radiation isocenter. The estimated accuracy of the method is ±0.2 mm. The observed reproducibility of the method is about ±0.1 mm. The total irradiation/illumination time is about 10 min per image. Data analysis, including the phosphor plate scanning, takes less than 5 min for each image. The method characterizes the radiation isocenter geometry with the high accuracy required for the stereotactic radiosurgery. In this respect, it is similar to the standard ball test for stereotactic machines. However, due to the usage of the MLC instead of the cross-hair/ball, it does not depend on the cross-hair/ball placement errors with respect to the lasers and it provides more information on the mechanical integrity of the linac/couch/laser system. Alternatively, it can be used as a highly accurate QA procedure for the nonstereotactic machines. Noteworthy is its

  13. 77 FR 2118 - In the Matter of the Designation of al-Qa'ida Kurdish Battalions (AQKB), Also Known as Kurdistan...

    Science.gov (United States)

    2012-01-13

    ... Battalions (AQKB), Also Known as Kurdistan Brigades, Also Known as Kurdistan Battalion of Islamic State in Iraq, Also Known as Kurdistan Brigade of al-Qaeda in Iraq, as a Specially Designated Global Terrorist... known as al-Qa'ida Kurdish Battalions (AQKB), also known as Kurdistan Brigades, also known as, Kurdistan...

  14. Experiences of Radiochemical Lab of Faculty of Natural Sciences, Comenius University, Bratislava, Slovakia with implementation of QA/QC system

    International Nuclear Information System (INIS)

    Rajec, Pavol; Mackova, Jana

    2002-01-01

    This report gives an overview of the Laboratory experience from the participation in the Project. The Project helped the Laboratory to obtain accreditation with the Slovak National Accreditation Service, to receive more contracts and clients and to implement QA/QC principles according to ISO 17025. The future plans of the Laboratory include ISO 17025 compliance certification

  15. Using Student Surveys to Monitor Teacher Effectiveness: Q&A with Dr. Ronald Ferguson. REL Mid-Atlantic Teacher Effectiveness Webinar Series

    Science.gov (United States)

    Regional Educational Laboratory Mid-Atlantic, 2013

    2013-01-01

    In this webinar, Dr. Ronald Ferguson, creator of the Tripod Project and Senior Lecturer at Harvard University Graduate School of Education, discussed the use of student surveys as an approach to measuring teacher effectiveness. This Q&A addressed the questions participants had for Dr. Ferguson following the webinar. The webinar recording and…

  16. SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cardin, A; Avery, S; Ding, X; Kassaee, A; Lin, L [University of Pennsylvania, Philadelphia, PA (United States); Maryanski, M [MGS Research, Inc., Madison, CT (United States)

    2014-06-15

    Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulated proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a

  17. Oxidized amino acid residues in the vicinity of Q(A and Pheo(D1 of the photosystem II reaction center: putative generation sites of reducing-side reactive oxygen species.

    Directory of Open Access Journals (Sweden)

    Laurie K Frankel

    Full Text Available Under a variety of stress conditions, Photosystem II produces reactive oxygen species on both the reducing and oxidizing sides of the photosystem. A number of different sites including the Mn4O5Ca cluster, P680, PheoD1, QA, QB and cytochrome b559 have been hypothesized to produce reactive oxygen species in the photosystem. In this communication using Fourier-transform ion cyclotron resonance mass spectrometry we have identified several residues on the D1 and D2 proteins from spinach which are oxidatively modified and in close proximity to QA (D1 residues (239F, (241Q, (242E and the D2 residues (238P, (239T, (242E and (247M and PheoD1 (D1 residues (130E, (133L and (135F. These residues may be associated with reactive oxygen species exit pathways located on the reducing side of the photosystem, and their modification may indicate that both QA and PheoD1 are sources of reactive oxygen species on the reducing side of Photosystem II.

  18. Test/QA plan for the verification testing of selective catalytic reduction control technologies for highway, nonroad use heavy-duty diesel engines

    Science.gov (United States)

    This ETV test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research (DER) describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR Part 89 for nonroad engines, will be ...

  19. Implementation of regional centres for SPECT QC/QA in Brazil

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Dias-Neto, A.L.; Abe, R.; Khoury, H.J.; Silva, D.C. da; Martini, J.C.; Brunetto, S.; Ney, C.

    2002-01-01

    Aims: SPECT technology was introduced in Brazil at the early 80s and, presently, there are more than 230 systems installed in the whole country. In order to establish a quality standard for these systems, a RCP was submitted and received partial support from IAEA for the implementation of regional centres, so that clinics in different regions could be evaluated using the same protocols. Materials and Methods: Six centres were created in 5 public (federal and state) universities and one private philanthropic medical school in: USP-Sao Paulo, UNICAMP-Campinas, CNEN-Rio de Janeiro, UFBA-Salvador, UFPE-Recife and FM/Santa Casa-Porto Alegre. All sites have teaching and technical supports available and there is at least one nuclear medicine physicist in charge. The basic QC/QA set included: 57 Co sheet source, orthogonal hole phantom, quadrant bar phantom, calibrated sources for dose calibrator ( 57 Co, 133 Ba, and 137 Cs) and a DeLuxe SPECT phantom from Data Spectrum Corp. Basic and complete/acceptance protocols were defined as the reference procedures. Measurements and evaluations were performed in 21 (<10%) centres and inter-comparisons were made amongst the groups. Results: Some information about the centres and evaluated systems are presented. A large number of the visited clinics never had any QC tests done except for the manufacturer's installation tests and the daily uniformity test. On the average, most of the cameras needed tuning and one of them had to have the PM tubes re-coupled. The main difficulties encountered by all groups were the lack of physicists in almost all the visited clinics and the inadequate training of many local technologists, especially in the remote areas. In spite of the misunderstanding and scepticism from some of the visited MDs, the majority recognized the importance of proper QC/QA testing. Conclusions: It was shown that regional centres are essential if one aims quality and reliability in the nuclear medicine clinics, especially in a

  20. Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and correlation to dose volume histogram based metrics.

    LENUS (Irish Health Repository)

    Coleman, Linda

    2013-11-01

    This study investigates the impact of systematic multileaf collimator (MLC) positional errors on gamma analysis results used for quality assurance (QA) of Rapidarc treatments. In addition, this study evaluates the relationship of these gamma analysis results and clinical dose volume histogram metrics (DVH) for Rapidarc treatment plans.

  1. MnMoO4 nanolayers : Synthesis characterizations and electrochemical detection of QA

    Science.gov (United States)

    Muthamizh, S.; Kumar, S. Praveen; Munusamy, S.; Narayanan, V.

    2018-04-01

    MnMoO4 nanolayers were prepared by precipitation method. The MnMoO4 nanolayers were synthesized by using commercially available (CH3COO)2Mn.4H2O and Na2WO4.2H2O. The XRD pattern reveals that the synthesized MnMoO4 has monoclinic structure. In addition, lattice parameter values were also calculated using XRD data. The Raman analysis confirm the presence of Mo-O in MnMoO4 nanolayers. DRS-UV analysis shows that MnMoO4 has a band gap of 2.59 eV. FE-SEM and HR-TEM analysis along with EDAX confirms the material morphology in stacked layers like structure in nano scale. Synthesized nanolayers were utilized for the detection of biomolecule quercetin (QA).

  2. Quality assurance and quality control in mammography: a review of available guidance worldwide.

    Science.gov (United States)

    Reis, Cláudia; Pascoal, Ana; Sakellaris, Taxiarchis; Koutalonis, Manthos

    2013-10-01

    Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources. •An effective QA program should be practical to implement in a clinical setting. •QA should address the various stages of the imaging chain: acquisition, processing and display. •AEC system QC testing is simple to implement and provides information on equipment performance.

  3. SU-F-T-282: Quality Assurance for IMRT/VMAT QA Devices: Issues Affecting the Timing for ArcCHECK Recalibration

    Energy Technology Data Exchange (ETDEWEB)

    Steers, J [Cedars Sinai Medical Center, Los Angeles, CA (United States); University of California-Los Angeles, Los Angeles, CA (United States); Fraass, B [Cedars Sinai Medical Center, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To discuss several factors surrounding the decision on when to recalibrate the ArcCHECK device as well as present a simple and efficient monthly check to evaluate ArcCHECK calibrations. Methods: ArcCheck (Sun Nuclear) calibrations were evaluated monthly by measuring a 25×25cm{sup 2} field with 100 MU. Since ArcCHECK measurements are run on an almost nightly basis, such additional square field measurements are obtained with minimal additional effort. An in-house MATLAB script compares two radial (y-direction) profiles from the top/center of the new measurement relative to a baseline measurement acquired at the last device calibration. The program automatically generates PDF profile and percent difference comparisons for inspection. Recalibration is based on inspection of measurement profile shapes and percent differences from the baseline measurement. Results: The method presented here shows the utility of a simple monthly check for evaluating ArcCHECK calibrations, and in addition shows the importance of recalibrating after Linac beam steering. Our device required recalibration approximately every 8–10 months. However, for ease of scheduling, we propose a bi-annual recalibration interval. Clinics with a lighter/heavier IMRT/VMAT QA case load may require different recalibration intervals, which are easily determined using the single-field method presented. Analysis of additional square fields is also easily incorporated, if desired. We further illustrate the importance of array recalibration given that diode irradiation is not uniform over the entire device, with central diodes receiving more than 900 Gy over the course of 10 months and peripheral diodes receiving as little as 50 Gy (in our experience). Finally, we show that timely device recalibration decreases spread in clinical IMRT/VMAT QA gamma passing rates. Conclusion: Quality assurance for ArcCHECK array calibrations is important to ensure quality IMRT/VMAT QA comparisons. For many clinics

  4. QA programme in external radiotherapy in Romania - status and perspective

    International Nuclear Information System (INIS)

    Dumitrescu, A.; Milu, C.

    2008-01-01

    Full text: Recognizing the importance of quality assurance in radiotherapy and the need to make access to radiation standards traceable to the international measurement system for every radiotherapy center, the Romanian national secondary standard dosimetry laboratory (SSDL) has started in 1999 - together with IAEA - a national quality audit programme in all the centers for external radiotherapy from Romania. At present, there are 17 radiotherapy centers in Romania, and a total of 19 teletherapy units and 4 LINCs. The programme has 3 phases: the first phase was to organize a survey in all radiotherapy centers, to collect general information on their radio therapists, medical physicists, type of equipment, dosimeters, etc. Following the survey, a quality assurance network was set up, and on-site dosimetry reviews were arranged according to a suitable timetable. The second phase consisted in performing the reference dosimetry and the calibration of the equipment. Then, a quality audit system based on mailed TLDs has been applied to all radiation beams produced by cobalt-60 therapy units and medical accelerators, in order to identify discrepancies in dosimetry larger than ± 3%. At the same time, the beam calibration performed by the SSDLs was verified. The results of the first survey were analyzed, and corrective actions were taken. A second survey was then organized, based on the mailed TLDs. This paper presents in detail the entire QA programme, its results, and the actions that are to be taken in order to improve the accuracy and consistency of the dosimetry in clinical radiotherapy in Romania. (author)

  5. QA and Testing in CERNBOX: the cornerstone of service development and operation

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    QA and Testing in CERNBOX (https://cernbox.cern.ch) presents a serious challenge and is critically important: - the service deals with user data directly on their local computers (synchronization clients), at present ~1000 clients connecting daily - the very nature of synchronization is to propagate changes across computers which also means propagating problems if they occur - there is a wide range of supported platforms (MacOSX, Windows, major Linux distributions, mobile platforms) - OS semantics are often incompatible or conflicting: for example HFS is case preserving, NTFS supports the legacy of 8.3 DOS file format, etc. - the operational environment varies enormously, for example: from fast, reliable network inside computing center to unreliable, high-latency, ad-hoc connections from airports - etc. From service development perspective, CERNBOX integrates several complex components which development cycles are disjoint and geographically distributed: - PB-range storage backend (EOS) developed...

  6. Development of the QA/QC Procedures for a Neutron Interrogation System

    Energy Technology Data Exchange (ETDEWEB)

    Obhodas, Jasmina; Sudac, Davorin; Valkovic, Vladivoj [Ruder Boskovic Institute, 10000 Zagreb (Croatia)

    2015-07-01

    In order to perform QA/QC procedures for a system dedicated to the neutron interrogation of objects for the presence of threat materials one needs to perform measurements of reference materials (RM) having the same (or similar) atomic ratios as real materials. It is well known that explosives, drugs, and various other benign materials, contain chemical elements such as hydrogen, oxygen, carbon and nitrogen in distinctly different quantities. For example, a high carbon-to-oxygen ratio (C/O) is characteristic of drugs. Explosives can be differentiated by measurement of both C/O and nitrogen-to-oxygen (N/O) ratios. The C/N ratio of the chemical warfare agents, coupled with the measurement of elements such as fluorine and phosphorus, clearly differentiate them from the conventional explosives. Correlations between theoretical values and experimental results obtained in laboratory conditions for C/O and N/C ratios of simulants of hexogen (RDX), TNT, DLM2, TATP, cocaine, heroin, yperite, tetranitromethane, peroxide methylethyl-ketone, nitromethane and ethyleneglycol dinitrate are presented. (authors)

  7. Brand new eyes: Thematic audits as a QA-tool for learning

    DEFF Research Database (Denmark)

    Silleborg, Ellen; Bendixen, Carsten; Jacobsen, Jens Christian

    2014-01-01

    What set of eyes do you put forward when you array a thematic audit trail – e.g. the eyes of a judge, a listener or a negotiator? A preliminary answer to this could be: “What we learn from an audit depends on our methodology”. Yes – so let’s work with it! The workshop is dedicated to questions li...... to programme theory. Afterwards we invite you to share your experiences and points of views about audits. The goal is to strengthen our use of audits as a tool for learning and QA in higher education.......What set of eyes do you put forward when you array a thematic audit trail – e.g. the eyes of a judge, a listener or a negotiator? A preliminary answer to this could be: “What we learn from an audit depends on our methodology”. Yes – so let’s work with it! The workshop is dedicated to questions like...

  8. Automated QA framework for PetaScale data challenges

    International Nuclear Information System (INIS)

    Van Buren, G; Didenko, L; Lauret, J; Oldag, E; Ray, L

    2011-01-01

    Over the lifetime of the STAR Experiment, a large investment of workforce time has gone into a variety of QA efforts, including continuous processing of a portion of the data for automated calibration and iterative convergence and quality assurance purposes. A rotating workforce coupled with ever-increasing volumes of information to examine led to sometimes inconsistent or incomplete reporting of issues, eventually leading to additional work. The traditional approach of manually screening a data sample was no longer adequate and doomed to eventual failure with planned future growth in data extents. To prevent this collapse we have developed a new system employing user-defined reference histograms, permitting automated comparisons and nagging of issues. Based on the ROOT framework at its core, the front end is a web based service allowing shift personnel to visualize the results, and to set test parameters and thresholds defining success or failure. The versatile and flexible approach allows for a slew of histograms to be configured and grouped into categories (results and thresholds may depend on experimental triggers and data types) ensuring framework evolution with the years of running to come. Historical information is also saved to track changes and allow for rapid convergence of future tuning. Database storage and processing of data are handled outside the web server for security and fault tolerance.

  9. SU-F-T-295: MLCs Performance and Patient-Specific IMRT QA Using Log File Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Osman, A [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); American University of Biuret Medical Center, Biuret (Lebanon); Maalej, N [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Jayesh, K; Abdel-Rahman, W [King Fahad Specialist Hospital-Dammam, Eastern Province (Saudi Arabia)

    2016-06-15

    Purpose: To analyze the performance of the multi-leaf collimators (MLCs) from the log files recorded during the intensity modulated radiotherapy (IMRT) treatment and to construct the relative fluence maps and do the gamma analysis to compare the planned and executed MLCs movement. Methods: We developed a program to extract and analyze the data from dynamic log files (dynalog files) generated from sliding window IMRT delivery treatments. The program extracts the planned and executed (actual or delivered) MLCs movement, calculates and compares the relative planned and executed fluences. The fluence maps were used to perform the gamma analysis (with 3% dose difference and 3 mm distance to agreement) for 3 IMR patients. We compared our gamma analysis results with those obtained from portal dose image prediction (PDIP) algorithm performed using the EPID. Results: For 3 different IMRT patient treatments, the maximum difference between the planned and the executed MCLs positions was 1.2 mm. The gamma analysis results of the planned and delivered fluences were in good agreement with the gamma analysis from portal dosimetry. The maximum difference for number of pixels passing the gamma criteria (3%/3mm) was 0.19% with respect to portal dosimetry results. Conclusion: MLC log files can be used to verify the performance of the MLCs. Patientspecific IMRT QA based on MLC movement log files gives similar results to EPID dosimetry results. This promising method for patient-specific IMRT QA is fast, does not require dose measurements in a phantom, can be done before the treatment and for every fraction, and significantly reduces the IMRT workload. The author would like to thank King Fahd University of petroleum and Minerals for the support.

  10. SU-E-T-184: Clinical VMAT QA Practice Using LINAC Delivery Log Files

    International Nuclear Information System (INIS)

    Johnston, H; Jacobson, T; Gu, X; Jiang, S; Stojadinovic, S

    2015-01-01

    Purpose: To evaluate the accuracy of volumetric modulated arc therapy (VMAT) treatment delivery dose clouds by comparing linac log data to doses measured using an ionization chamber and film. Methods: A commercial IMRT quality assurance (QA) process utilizing a DICOM-RT framework was tested for clinical practice using 30 prostate and 30 head and neck VMAT plans. Delivered 3D VMAT dose distributions were independently checked using a PinPoint ionization chamber and radiographic film in a solid water phantom. DICOM RT coordinates were used to extract the corresponding point and planar doses from 3D log file dose distributions. Point doses were evaluated by computing the percent error between log file and chamber measured values. A planar dose evaluation was performed for each plan using a 2D gamma analysis with 3% global dose difference and 3 mm isodose point distance criteria. The same analysis was performed to compare treatment planning system (TPS) doses to measured values to establish a baseline assessment of agreement. Results: The mean percent error between log file and ionization chamber dose was 1.0%±2.1% for prostate VMAT plans and −0.2%±1.4% for head and neck plans. The corresponding TPS calculated and measured ionization chamber values agree within 1.7%±1.6%. The average 2D gamma passing rates for the log file comparison to film are 98.8%±1.0% and 96.2%±4.2% for the prostate and head and neck plans, respectively. The corresponding passing rates for the TPS comparison to film are 99.4%±0.5% and 93.9%±5.1%. Overall, the point dose and film data indicate that log file determined doses are in excellent agreement with measured values. Conclusion: Clinical VMAT QA practice using LINAC treatment log files is a fast and reliable method for patient-specific plan evaluation

  11. Expression and subcellular localization of the Qa-SNARE syntaxin17 in human eosinophils

    International Nuclear Information System (INIS)

    Carmo, Lívia A.S.; Dias, Felipe F.; Malta, Kássia K.; Amaral, Kátia B.; Shamri, Revital; Weller, Peter F.; Melo, Rossana C.N.

    2015-01-01

    Background: SNARE members mediate membrane fusion during intracellular trafficking underlying innate and adaptive immune responses by different cells. However, little is known about the expression and function of these proteins in human eosinophils, cells involved in allergic, inflammatory and immunoregulatory responses. Here, we investigate the expression and distribution of the Qa-SNARE syntaxin17 (STX17) within human eosinophils isolated from the peripheral blood. Methods: Flow cytometry and a pre-embedding immunonanogold electron microscopy (EM) technique that combines optimal epitope preservation and secondary Fab-fragments of antibodies linked to 1.4 nm gold particles for optimal access to microdomains, were used to investigate STX17. Results: STX17 was detected within unstimulated eosinophils. Immunogold EM revealed STX17 on secretory granules and on granule-derived vesiculotubular transport carriers (Eosinophil Sombrero Vesicles-EoSVs). Quantitative EM analyses showed that 77.7% of the granules were positive for STX17 with a mean±SEM of 3.9±0.2 gold particles/granule. Labeling was present on both granule outer membranes and matrices while EoSVs showed clear membrane-associated labeling. STX17 was also present in secretory granules in eosinophils stimulated with the cytokine tumor necrosis factor alpha (TNF-α) or the CC-chemokine ligand 11 CCL11 (eotaxin-1), stimuli that induce eosinophil degranulation. The number of secretory granules labeled for STX17 was significantly higher in CCL11 compared with the unstimulated group. The level of cell labeling did not change when unstimulated cells were compared with TNF-α-stimulated eosinophils. Conclusions: The present study clearly shows by immunanonogold EM that STX17 is localized in eosinophil secretory granules and transport vesicles and might be involved in the transport of granule-derived cargos. - Highlights: • First demonstration of the Qa-SNARE syntaxin-17 (STX17) in human eosinophils. • High

  12. Expression and subcellular localization of the Qa-SNARE syntaxin17 in human eosinophils

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lívia A.S.; Dias, Felipe F.; Malta, Kássia K.; Amaral, Kátia B. [Laboratory of Cellular Biology, Department of Biology, Federal University of Juiz de Fora, UFJF, Juiz de Fora, MG (Brazil); Shamri, Revital; Weller, Peter F. [Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA (United States); Melo, Rossana C.N., E-mail: rossana.melo@ufjf.edu.br [Laboratory of Cellular Biology, Department of Biology, Federal University of Juiz de Fora, UFJF, Juiz de Fora, MG (Brazil); Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA (United States)

    2015-10-01

    Background: SNARE members mediate membrane fusion during intracellular trafficking underlying innate and adaptive immune responses by different cells. However, little is known about the expression and function of these proteins in human eosinophils, cells involved in allergic, inflammatory and immunoregulatory responses. Here, we investigate the expression and distribution of the Qa-SNARE syntaxin17 (STX17) within human eosinophils isolated from the peripheral blood. Methods: Flow cytometry and a pre-embedding immunonanogold electron microscopy (EM) technique that combines optimal epitope preservation and secondary Fab-fragments of antibodies linked to 1.4 nm gold particles for optimal access to microdomains, were used to investigate STX17. Results: STX17 was detected within unstimulated eosinophils. Immunogold EM revealed STX17 on secretory granules and on granule-derived vesiculotubular transport carriers (Eosinophil Sombrero Vesicles-EoSVs). Quantitative EM analyses showed that 77.7% of the granules were positive for STX17 with a mean±SEM of 3.9±0.2 gold particles/granule. Labeling was present on both granule outer membranes and matrices while EoSVs showed clear membrane-associated labeling. STX17 was also present in secretory granules in eosinophils stimulated with the cytokine tumor necrosis factor alpha (TNF-α) or the CC-chemokine ligand 11 CCL11 (eotaxin-1), stimuli that induce eosinophil degranulation. The number of secretory granules labeled for STX17 was significantly higher in CCL11 compared with the unstimulated group. The level of cell labeling did not change when unstimulated cells were compared with TNF-α-stimulated eosinophils. Conclusions: The present study clearly shows by immunanonogold EM that STX17 is localized in eosinophil secretory granules and transport vesicles and might be involved in the transport of granule-derived cargos. - Highlights: • First demonstration of the Qa-SNARE syntaxin-17 (STX17) in human eosinophils. • High

  13. SU-E-T-04: 3D Dose Based Patient Compensator QA Procedure for Proton Radiotherapy

    International Nuclear Information System (INIS)

    Zou, W; Reyhan, M; Zhang, M; Davis, R; Jabbour, S; Khan, A; Yue, N

    2015-01-01

    Purpose: In proton double-scattering radiotherapy, compensators are the essential patient specific devices to contour the distal dose distribution to the tumor target. Traditional compensator QA is limited to checking the drilled surface profiles against the plan. In our work, a compensator QA process was established that assess the entire compensator including its internal structure for patient 3D dose verification. Methods: The fabricated patient compensators were CT scanned. Through mathematical image processing and geometric transformations, the CT images of the proton compensator were combined with the patient simulation CT images into a new series of CT images, in which the imaged compensator is placed at the planned location along the corresponding beam line. The new CT images were input into the Eclipse treatment planning system. The original plan was calculated to the combined CT image series without the plan compensator. The newly computed patient 3D dose from the combined patientcompensator images was verified against the original plan dose. Test plans include the compensators with defects intentionally created inside the fabricated compensators. Results: The calculated 3D dose with the combined compensator and patient CT images reflects the impact of the fabricated compensator to the patient. For the test cases in which no defects were created, the dose distributions were in agreement between our method and the corresponding original plans. For the compensator with the defects, the purposely changed material and a purposely created internal defect were successfully detected while not possible with just the traditional compensator profiles detection methods. Conclusion: We present here a 3D dose verification process to qualify the fabricated proton double-scattering compensator. Such compensator detection process assesses the patient 3D impact of the fabricated compensator surface profile as well as the compensator internal material and structure changes

  14. 3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production

    Energy Technology Data Exchange (ETDEWEB)

    Da Vià, Cinzia; Boscardil, Maurizio; Dalla Betta, GianFranco; Darbo, Giovanni; Fleta, Celeste; Gemme, Claudia; Giacomini, Gabriele; Grenier, Philippe; Grinstein, Sebastian; Hansen, Thor-Erik; Hasi, Jasmine; Kenney, Christopher; Kok, Angela; La Rosa, Alessandro; Micelli, Andrea; Parker, Sherwood; Pellegrini, Giulio; Pohl, David-Leon; Povoli, Marco; Vianello, Elisa; Zorzi, Nicola; Watts, S. J.

    2013-01-01

    3D silicon sensors, where plasma micromachining is used to etch deep narrow apertures in the silicon substrate to form electrodes of PIN junctions, were successfully manufactured in facilities in Europe and USA. In 2011 the technology underwent a qualification process to establish its maturity for a medium scale production for the construction of a pixel layer for vertex detection, the Insertable B-Layer (IBL) at the CERN-LHC ATLAS experiment. The IBL collaboration, following that recommendation from the review panel, decided to complete the production of planar and 3D sensors and endorsed the proposal to build enough modules for a mixed IBL sensor scenario where 25% of 3D modules populate the forward and backward part of each stave. The production of planar sensors will also allow coverage of 100% of the IBL, in case that option was required. This paper will describe the processing strategy which allowed successful 3D sensor production, some of the Quality Assurance (QA) tests performed during the pre-production phase and the production yield to date.

  15. 3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production

    Energy Technology Data Exchange (ETDEWEB)

    Da Vià, Cinzia, E-mail: cinzia.da.via@cern.ch [School of Physics and Astronomy, The University of Manchester, Oxford Road, M13 9PL Manchester (United Kingdom); Boscardil, Maurizio [Fondazione Bruno Kessler, FBK-CMM, Via Sommarive 18, I-38123 Trento (Italy); Dalla Betta, GianFranco [DISI, Università degli Studi di Trento and INFN, Via Sommarive 14, I-38123 Trento (Italy); Darbo, Giovanni [INFN Sezione di Genova, Via Dodecaneso 33, I-14146 Genova (Italy); Fleta, Celeste [Centro Nacional de Microelectronica, CNM-IMB (CSIC), Barcelona E-08193 (Spain); Gemme, Claudia [INFN Sezione di Genova, Via Dodecaneso 33, I-14146 Genova (Italy); Giacomini, Gabriele [Fondazione Bruno Kessler, FBK-CMM, Via Sommarive 18, I-38123 Trento (Italy); Grenier, Philippe [SLAC National Accelerator Laboratory, 2575 Sand Hill Rd, Menlo Park, CA 94025 (United States); Grinstein, Sebastian [Institut de Fisica d' Altes Energies (IFAE) and ICREA, Universitat Autonoma de Barcelona (UAB) E-08193, Bellaterra, Barcelona (Spain); Hansen, Thor-Erik [SINTEF MiNaLab, Blindern, N-0314 Oslo (Norway); Hasi, Jasmine; Kenney, Christopher [SLAC National Accelerator Laboratory, 2575 Sand Hill Rd, Menlo Park, CA 94025 (United States); Kok, Angela [SINTEF MiNaLab, Blindern, N-0314 Oslo (Norway); La Rosa, Alessandro [CERN CH 1211, Geneva 23 (Switzerland); Micelli, Andrea [Tne University of Udine and INFN, via del Cotonificio 108, 33100 Udine (Italy); Parker, Sherwood [University of Hawaii, c/o Lawrence Berkeley Laboratory, Berkeley, CA 94720 (United States); Pellegrini, Giulio [Centro Nacional de Microelectronica, CNM-IMB (CSIC), Barcelona E-08193 (Spain); Pohl, David-Leon [Physikalisches Institut der Universität Bonn, Nußallee 12 D-53115, Bonn, Federal Republic of Germany (Germany); Povoli, Marco [DISI, Università degli Studi di Trento and INFN, Via Sommarive 14, I-38123 Trento (Italy); and others

    2013-01-21

    3D silicon sensors, where plasma micromachining is used to etch deep narrow apertures in the silicon substrate to form electrodes of PIN junctions, were successfully manufactured in facilities in Europe and USA. In 2011 the technology underwent a qualification process to establish its maturity for a medium scale production for the construction of a pixel layer for vertex detection, the Insertable B-Layer (IBL) at the CERN-LHC ATLAS experiment. The IBL collaboration, following that recommendation from the review panel, decided to complete the production of planar and 3D sensors and endorsed the proposal to build enough modules for a mixed IBL sensor scenario where 25% of 3D modules populate the forward and backward part of each stave. The production of planar sensors will also allow coverage of 100% of the IBL, in case that option was required. This paper will describe the processing strategy which allowed successful 3D sensor production, some of the Quality Assurance (QA) tests performed during the pre-production phase and the production yield to date.

  16. SU-F-P-54: Guidelines to Check Image Registration QA of a Clinical Deformation Registration Software: A Single Institution Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Gill, G; Souri, S; Rea, A; Chen, Y; Antone, J; Qian, X; Riegel, A; Taylor, P; Marrero, M; Diaz, F; Cao, Y; Jamshidi, A; Klein, E [Northwell Health, Lake Success, NY (United States); Barley, S; Sorell, V; Karangelis, G [Oncology Systems Limited, Longbow Close, Shrewsbury SY1 3GZ (United Kingdom); Button, T [Stony Brook University Hospital, Stony Brook, NY (United States)

    2016-06-15

    Purpose: The objective of this study is to verify and analyze the accuracy of a clinical deformable image registration (DIR) software. Methods: To test clinical DIR software qualitatively and quantitatively, we focused on lung radiotherapy and analyzed a single (Lung) patient CT scan. Artificial anatomical changes were applied to account for daily variations during the course of treatment including the planning target volume (PTV) and organs at risk (OAR). The primary CT (pCT) and the structure set (pST) was deformed with commercial tool (ImSimQA-Oncology Systems Limited) and after artificial deformation (dCT and dST) sent to another commercial tool (VelocityAI-Varian Medical Systems). In Velocity, the deformed CT and structures (dCT and dST) were inversely deformed back to original primary CT (dbpCT and dbpST). We compared the dbpST and pST structure sets using similarity metrics. Furthermore, a binary deformation field vector (BDF) was created and sent to ImSimQA software for comparison with known “ground truth” deformation vector fields (DVF). Results: An image similarity comparison was made by using “ground truth” DVF and “deformed output” BDF with an output of normalized “cross correlation (CC)” and “mutual information (MI)” in ImSimQA software. Results for the lung case were MI=0.66 and CC=0.99. The artificial structure deformation in both pST and dbpST was analyzed using DICE coefficient, mean distance to conformity (MDC) and deformation field error volume histogram (DFEVH) by comparing them before and after inverse deformation. We have noticed inadequate structure match for CTV, ITV and PTV due to close proximity of heart and overall affected by lung expansion. Conclusion: We have seen similarity between pCT and dbpCT but not so well between pST and dbpST, because of inadequate structure deformation in clinical DIR system. This system based quality assurance test will prepare us for adopting the guidelines of upcoming AAPM task group 132

  17. SU-F-P-54: Guidelines to Check Image Registration QA of a Clinical Deformation Registration Software: A Single Institution Preliminary Study

    International Nuclear Information System (INIS)

    Gill, G; Souri, S; Rea, A; Chen, Y; Antone, J; Qian, X; Riegel, A; Taylor, P; Marrero, M; Diaz, F; Cao, Y; Jamshidi, A; Klein, E; Barley, S; Sorell, V; Karangelis, G; Button, T

    2016-01-01

    Purpose: The objective of this study is to verify and analyze the accuracy of a clinical deformable image registration (DIR) software. Methods: To test clinical DIR software qualitatively and quantitatively, we focused on lung radiotherapy and analyzed a single (Lung) patient CT scan. Artificial anatomical changes were applied to account for daily variations during the course of treatment including the planning target volume (PTV) and organs at risk (OAR). The primary CT (pCT) and the structure set (pST) was deformed with commercial tool (ImSimQA-Oncology Systems Limited) and after artificial deformation (dCT and dST) sent to another commercial tool (VelocityAI-Varian Medical Systems). In Velocity, the deformed CT and structures (dCT and dST) were inversely deformed back to original primary CT (dbpCT and dbpST). We compared the dbpST and pST structure sets using similarity metrics. Furthermore, a binary deformation field vector (BDF) was created and sent to ImSimQA software for comparison with known “ground truth” deformation vector fields (DVF). Results: An image similarity comparison was made by using “ground truth” DVF and “deformed output” BDF with an output of normalized “cross correlation (CC)” and “mutual information (MI)” in ImSimQA software. Results for the lung case were MI=0.66 and CC=0.99. The artificial structure deformation in both pST and dbpST was analyzed using DICE coefficient, mean distance to conformity (MDC) and deformation field error volume histogram (DFEVH) by comparing them before and after inverse deformation. We have noticed inadequate structure match for CTV, ITV and PTV due to close proximity of heart and overall affected by lung expansion. Conclusion: We have seen similarity between pCT and dbpCT but not so well between pST and dbpST, because of inadequate structure deformation in clinical DIR system. This system based quality assurance test will prepare us for adopting the guidelines of upcoming AAPM task group 132

  18. Test/QA plan for the verification testing of diesel exhaust catalysts, particulate filters and engine modification control technologies for highway and nonroad use diesel engines

    Science.gov (United States)

    This ETV test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research (DER) describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR Part 89 for nonroad engines, will be ...

  19. Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

    Energy Technology Data Exchange (ETDEWEB)

    Ebe, Kazuyu, E-mail: nrr24490@nifty.com; Tokuyama, Katsuichi; Baba, Ryuta; Ogihara, Yoshisada; Ichikawa, Kosuke; Toyama, Joji [Joetsu General Hospital, 616 Daido-Fukuda, Joetsu-shi, Niigata 943-8507 (Japan); Sugimoto, Satoru [Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo 113-8421 (Japan); Utsunomiya, Satoru; Kagamu, Hiroshi; Aoyama, Hidefumi [Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510 (Japan); Court, Laurence [The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-08-15

    Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors

  20. Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

    International Nuclear Information System (INIS)

    Ebe, Kazuyu; Tokuyama, Katsuichi; Baba, Ryuta; Ogihara, Yoshisada; Ichikawa, Kosuke; Toyama, Joji; Sugimoto, Satoru; Utsunomiya, Satoru; Kagamu, Hiroshi; Aoyama, Hidefumi; Court, Laurence

    2015-01-01

    Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors

  1. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  2. SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

    International Nuclear Information System (INIS)

    Syh, J; Wu, H

    2015-01-01

    Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center

  3. Dual purpose QA tool developed for teletherapy unit and CT scan in SNDH

    International Nuclear Information System (INIS)

    Shilvant, D.V.; Tamane, C.J.; Pangam, S.B.; Raees, M.D.; Aynoor, S.K.; Pol, P.S.; Verghese, Aju; Ghorpade, C.J.

    2007-01-01

    To make a simple device used in Teletherapy unit and CT scan for depth data measurement. The accurate depth data is essential and very important factor for precise treatment in SAD isocentric setup calculation. In CT scan based treatment planning, the calculation obtained is from the depth given by the CT scan. The success of treatment depends on the same parameters in treatment unit matched with diagnostic CT scan data. To check the depth parameters in both CT scan and Teletherapy unit we have developed a single QA tool in our hospital. As this tool is precise, handy and easily accessible the results obtained from it assures the quality of Teletherapy unit as well as CT scan depth data. This small device resulted data helps a lot in calculations of complicated SAD setup in Telecobalt and also useful in recent new treatment modalities such as IMRT, micro MLC, etc

  4. Environmental analytical laboratory setup operation and QA/QC

    International Nuclear Information System (INIS)

    Hsu, J.P.; Boyd, J.A.; DeViney, S.

    1991-01-01

    Environmental analysis requires precise and timely measurements. The required precise measurement is ensured with quality control and timeliness through an efficient operation. The efficiency of the operation also ensures cost-competitiveness. Environmental analysis plays a very important role in the environmental protection program. Due to the possible litigation involvement, most environmental analyses follow stringent criteria, such as the U.S. EPA Contract Laboratory Program procedures with analytical results documented in an orderly manner. The documentation demonstrates that all quality control steps are followed and facilitates data evaluation to determine the quality and usefulness of the data. Furthermore, the tedious documents concerning sample checking, chain-of-custody, standard or surrogate preparation, daily refrigerator and oven temperature monitoring, analytical and extraction logbooks, standard operation procedures, etc., also are an important part of the laboratory documentation. Quality control for environmental analysis is becoming more stringent, required documentation is becoming more detailed and turnaround time is shorter. However, the business is becoming more cost-competitive and it appears that this trend will continue. In this paper, we discuss what should be done to deal this high quality, fast-paced and tedious environmental analysis process at a competitive cost. The success of environmental analysis is people. The knowledge and experience of the staff are the key to a successful environmental analysis program. In order to be successful in this new area, the ability to develop new methods is crucial. In addition, the laboratory information system, laboratory automation and quality assurance/quality control (QA/QC) are major factors for laboratory success. This paper concentrates on these areas

  5. Lesson Development for English Learners in Content Area Settings: Key Considerations. Q&A with Sarah Catherine K. Moore, Ph.D. 2016 Educator Effectiveness Webinar Series

    Science.gov (United States)

    Moore, Sarah Catherine K.

    2016-01-01

    In this webinar, Dr. Sarah Catherine K. Moore, Program Director at the Center for Applied Linguistics, outlined factors for content area teachers to consider as they design and deliver lessons for mainstream classrooms that include English learner (EL) students. This Q&A addressed the questions participants had for Dr. Moore following the…

  6. Evaluation of the Slovak national mammography QA audit and the consequences for mammography screening

    International Nuclear Information System (INIS)

    Horvathova, M; Nikodemova, D.

    2005-01-01

    Council Directive 97/43/EURATOM establishes that member states shall ensure that practitioners and technical staff in medical practice have adequate theoretical and practical training for the purpose of radiological practices as well as relevant competence in radiation protection. This is considered as a basic aspect of optimization of medical exposure. A general background of the required level of training in radiation protection is given in Guidelines on education and training in radiation protection in medical exposures published by European Commission (116/2000/EURATOM). The aim of our paper is to refer about a new education system. Recommendation for continuing education and training is given and new techniques are implemented. The introduced quality assurance and quality control programs were realized in the framework of activities of the Committee of QA and QC in radiology under auspice of Slovak Health (authors)

  7. Comparison of calculated and experimental isotope edited FTIR difference spectra for purple bacterial photosynthetic reaction centers with different quinones incorporated into the QA binding site.

    Directory of Open Access Journals (Sweden)

    Nan eZhao

    2013-08-01

    Full Text Available Previously we have shown that ONIOM type (QM/MM calculations can be used to simulate isotope edited FTIR difference spectra for neutral ubiquinone in the QA binding site in Rhodobacter sphaeroides photosynthetic reaction centers. Here we considerably extend upon this previous work by calculating isotope edited FTIR difference spectra for reaction centers with a variety of unlabeled and 18O labeled foreign quinones incorporated into the QA binding site. Isotope edited spectra were calculated for reaction centers with 2,3-dimethoxy-5,6-dimethyl-1,4-benzoquinone (MQ0, 2,3,5,6-tetramethyl-1,4-benzoquinone (duroquinone, DQ, and 2,3-dimethyl-l,4-naphthoquinone (DMNQ incorporated, and compared to corresponding experimental spectra. The calculated and experimental spectra agree well, further demonstrating the utility and applicability of our ONIOM approach for calculating the vibrational properties of pigments in protein binding sites.The normal modes that contribute to the bands in the calculated spectra, their composition, frequency and intensity, and how these quantities are modified upon 18O labeling, are presented. This computed information leads to a new and more detailed understanding/interpretation of the experimental FTIR difference spectra. Hydrogen bonding to the carbonyl groups of the incorporated quinones is shown to be relatively weak. It is also shown that there is some asymmetry in hydrogen bonding, accounting for 10-13 cm-1 separation in the frequencies of the carbonyl vibrational modes of the incorporated quinones. The extent of asymmetry H-bonding could only be established by considering the spectra for various types of quinones incorporated into the QA binding site. The quinones listed above are tail-less. Spectra were also calculated for reaction centers with corresponding tail containing quinones incorporated, and it is found that replacement of the quinone methyl group by a phytyl or prenyl chain does not alter ONIOM calculated s

  8. SU-F-I-51: CT/MR Image Deformation: The Clinical Assessment QA in Target Delineation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C; Chen, Y [Monmouth Medical Center, Long Branch, NJ (United States)

    2016-06-15

    Purpose: To study the deformation effects in CT/MR image registration of head and neck (HN) cancers. We present a clinical indication in guiding and simplifying registration procedures of this process while CT images possessed artifacts. Methods: CT/MR image fusion provides better soft tissue contrast in intracranial GTV definition with artifacts. However, whether the fusion process should include the deformation process is questionable and not recommended. We performed CT/MR image registration of a HN patient with tonsil GTV and nodes delineation on Varian Velocity™ system. Both rigid transformation and deformable registration of the same CT/MR imaging data were processed separately. Physician’s selection of target delineation was implemented to identify the variations. Transformation matrix was shown with visual identification, as well as the deformation QA numbers and figures were assessed. Results: The deformable CT/MR images were traced with the calculated matrix, both translation and rotational parameters were summarized. In deformable quality QA, the calculated Jacobian matrix was analyzed, which the min/mean/max of 0.73/0/99/1.37, respectively. Jacobian matrix of right neck node was 0.84/1.13/1.41, which present dis-similarity of the nodal area. If Jacobian = 1, the deformation is at the optimum situation. In this case, the deformation results have shown better target delineation for CT/MR deformation than rigid transformation. Though the root-mean-square vector difference is 1.48 mm, with similar rotational components, the cord and vertebrae position were aligned much better in the deformable MR images than the rigid transformation. Conclusion: CT/MR with/without image deformation presents similar image registration matrix; there were significant differentiate the anatomical structures in the region of interest by deformable process. Though vendor suggested only rigid transformation between CT/MR assuming the geometry remain similar, our findings

  9. Development of JAEA sorption database (JAEA-SDB). Update of sorption/QA data in FY2015

    International Nuclear Information System (INIS)

    Tachi, Yukio; Suyama, Tadahiro

    2016-03-01

    Sorption and diffusion of radionuclides in buffer materials (bentonite) and rocks are the key processes in the safe geological disposal of radioactive waste, because migration of radionuclides in these barrier materials is expected to be diffusion-controlled and retarded by sorption processes. It is therefore necessary to understand the sorption and diffusion processes and develop databases compiling reliable data and mechanistic/predictive models, so that reliable parameters can be set under a variety of geochemical conditions relevant to performance assessment (PA). For this purpose, Japan Atomic Energy Agency (JAEA) has developed databases of sorption and diffusion parameters in bentonites and rocks. These sorption and diffusion databases (SDB/DDB) were firstly developed as an important basis for the H12 PA of high-level radioactive waste disposal, and have been provided through the Web. JAEA has been continuing to improve and update the SDB/DDB in view of potential future data needs, focusing on assuring the desired quality level and testing the usefulness of the databases for possible applications to PA-related parameter setting. The present report focuses on improving and updating of the sorption database (JAEA-SDB) as basis of integrated approach for PA-related K d setting and mechanistic sorption model development. This includes an overview of database structure, contents and functions including additional data evaluation function focusing on statistical data evaluation and grouping of data related to potential perturbations. K d data and their QA results are updated by focusing our recent activities on the K d setting and mechanistic model development. As a result, 11,206 K d data from 83 references were added, total number of K d values in the JAEA-SDB reached about 58,000. The QA/classified K d data reached about 60% for all K d data in JAEA-SDB. The updated JAEA-SDB is expected to make it possible to obtain quick overview of the available data, and to

  10. Test/QA plan for the verification testing of alternative or reformulated liquid fuels, fuel additives, fuel emulsions, and lubricants for highway and nonroad use heavy-duty diesel engines

    Science.gov (United States)

    This Environmental Technology Verification Program test/QA plan for heavy-duty diesel engine testing at the Southwest Research Institute’s Department of Emissions Research describes how the Federal Test Procedure (FTP), as listed in 40 CFR Part 86 for highway engines and 40 CFR P...

  11. Review of Quality Assurance in SKB's Repository Research Experiments

    International Nuclear Information System (INIS)

    Hicks, T.W.

    2007-01-01

    SKB is preparing licence applications for a spent nuclear fuel encapsulation plant and repository which will be supported by the SR-Site safety report. A separate safety report, SR-Can, has been produced by SKB in preparation for the SR-Site report. SKI is in the process of reviewing the SR-Can safety report. In preparation for this review, and with a view to building confidence in SKB's research activities and understanding SKB's handling of data and other information, SKI has examined SKB's application of QA measures in the management and conduct of repository research and development projects that support the SR-Can safety assessment. These preliminary investigations will serve to support the preparation of more detailed quality and technical audits of SKB's repository safety assessment after the submission of a licence application. SKI's approach to this QA review is based on the consideration of quality-affecting aspects of a selection of SKB's research and development activities. As part of this review, SKI identified the need to examine quality-related aspects of some of the many experiments and investigations that form part of SKB's repository research programme. This report presents the findings of such a review, focusing on experiments concerned with the properties and performance of the engineered barrier system. First, in order to establish a broad understanding of QA requirements for repository scientific investigations, QA procedures implemented in the management of research and development activities for the low-level radioactive waste repository near Drigg in the UK and the Waste Isolation Pilot Plant and Yucca Mountain repository projects in the US were studied. The QA procedures for experiments and tests undertaken in these projects were compared with those implemented by SKB. Key findings are: QA programmes have been implemented for each repository development programme in response to regulatory requirements. The need for regular audits of the

  12. Tuning cofactor redox potentials: the 2-methoxy dihedral angle generates a redox potential difference of >160 mV between the primary (Q(A)) and secondary (Q(B)) quinones of the bacterial photosynthetic reaction center.

    Science.gov (United States)

    Taguchi, Alexander T; Mattis, Aidas J; O'Malley, Patrick J; Dikanov, Sergei A; Wraight, Colin A

    2013-10-15

    Only quinones with a 2-methoxy group can act simultaneously as the primary (QA) and secondary (QB) electron acceptors in photosynthetic reaction centers from Rhodobacter sphaeroides. (13)C hyperfine sublevel correlation measurements of the 2-methoxy in the semiquinone states, SQA and SQB, were compared with quantum mechanics calculations of the (13)C couplings as a function of the dihedral angle. X-ray structures support dihedral angle assignments corresponding to a redox potential gap (ΔEm) between QA and QB of ~180 mV. This is consistent with the failure of a ubiquinone analogue lacking the 2-methoxy to function as QB in mutant reaction centers with a ΔEm of ≈160-195 mV.

  13. SU-F-T-292: Imaging and Radiation Oncology Core (IROC) Houston QA Center’s Anthropomorphic Phantom Program

    International Nuclear Information System (INIS)

    Mehrens, H; Lewis, B; Lujano, C; Nguyen, T; Hernandez, N; Alvarez, P; Molineu, A; Followill, D

    2016-01-01

    Purpose: To describe the results of IROC Houston’s international and domestic end-to-end QA phantom irradiations. Methods: IROC Houston has anthropomorphic lung, liver, head and neck, prostate, SRS and spine phantoms that are used for credentialing and quality assurance purposes. The phantoms include structures that closely mimic targets and organs at risk and are made from tissue equivalent materials: high impact polystyrene, solid water, cork and acrylic. Motion tables are used to mimic breathing motion for some lung and liver phantoms. Dose is measured with TLD and radiochromic film in various planes within the target of the phantoms. Results: The most common phantom requested is the head and neck followed by the lung phantom. The head and neck phantom was sent to 800 domestic and 148 international sites between 2011 and 2015, with average pass rates of 89% and 92%, respectively. During the past five years, a general upward trend exists regarding demand for the lung phantom for both international and domestic sites with international sites more than tripling from 5 (2011) to 16 (2015) and domestic sites doubling from 66 (2011) to 152 (2015). The pass rate for lung phantoms has been consistent from year to year despite this large increase in the number of phantoms irradiated with an average pass rate of 85% (domestic) and 95% (international) sites. The percentage of lung phantoms used in combination with motions tables increased from 38% to 79% over the 5 year time span. Conclusion: The number of domestic and international sites irradiating the head and neck and lung phantoms continues to increase and the pass rates remained constant. These end-to-end QA tests continue to be a crucial part of clinical trial credentialing and institution quality assurance. This investigation was supported by IROC grant CA180803 awarded by the NCI.

  14. Intraoperative imaging for patient safety and QA: detection of intracranial hemorrhage using C-arm cone-beam CT

    Science.gov (United States)

    Schafer, Sebastian; Wang, Adam; Otake, Yoshito; Stayman, J. W.; Zbijewski, Wojciech; Kleinszig, Gerhard; Xia, Xuewei; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2013-03-01

    Intraoperative imaging could improve patient safety and quality assurance (QA) via the detection of subtle complications that might otherwise only be found hours after surgery. Such capability could therefore reduce morbidity and the need for additional intervention. Among the severe adverse events that could be more quickly detected by high-quality intraoperative imaging is acute intracranial hemorrhage (ICH), conventionally assessed using post-operative CT. A mobile C-arm capable of high-quality cone-beam CT (CBCT) in combination with advanced image reconstruction techniques is reported as a means of detecting ICH in the operating room. The system employs an isocentric C-arm with a flat-panel detector in dual gain mode, correction of x-ray scatter and beam-hardening, and a penalized likelihood (PL) iterative reconstruction method. Performance in ICH detection was investigated using a quantitative phantom focusing on (non-contrast-enhanced) blood-brain contrast, an anthropomorphic head phantom, and a porcine model with injection of fresh blood bolus. The visibility of ICH was characterized in terms of contrast-to-noise ratio (CNR) and qualitative evaluation of images by a neurosurgeon. Across a range of size and contrast of the ICH as well as radiation dose from the CBCT scan, the CNR was found to increase from ~2.2-3.7 for conventional filtered backprojection (FBP) to ~3.9-5.4 for PL at equivalent spatial resolution. The porcine model demonstrated superior ICH detectability for PL. The results support the role of high-quality mobile C-arm CBCT employing advanced reconstruction algorithms for detecting subtle complications in the operating room at lower radiation dose and lower cost than intraoperative CT scanners and/or fixedroom C-arms. Such capability could present a potentially valuable aid to patient safety and QA.

  15. SU-F-T-292: Imaging and Radiation Oncology Core (IROC) Houston QA Center’s Anthropomorphic Phantom Program

    Energy Technology Data Exchange (ETDEWEB)

    Mehrens, H; Lewis, B; Lujano, C; Nguyen, T; Hernandez, N; Alvarez, P; Molineu, A; Followill, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To describe the results of IROC Houston’s international and domestic end-to-end QA phantom irradiations. Methods: IROC Houston has anthropomorphic lung, liver, head and neck, prostate, SRS and spine phantoms that are used for credentialing and quality assurance purposes. The phantoms include structures that closely mimic targets and organs at risk and are made from tissue equivalent materials: high impact polystyrene, solid water, cork and acrylic. Motion tables are used to mimic breathing motion for some lung and liver phantoms. Dose is measured with TLD and radiochromic film in various planes within the target of the phantoms. Results: The most common phantom requested is the head and neck followed by the lung phantom. The head and neck phantom was sent to 800 domestic and 148 international sites between 2011 and 2015, with average pass rates of 89% and 92%, respectively. During the past five years, a general upward trend exists regarding demand for the lung phantom for both international and domestic sites with international sites more than tripling from 5 (2011) to 16 (2015) and domestic sites doubling from 66 (2011) to 152 (2015). The pass rate for lung phantoms has been consistent from year to year despite this large increase in the number of phantoms irradiated with an average pass rate of 85% (domestic) and 95% (international) sites. The percentage of lung phantoms used in combination with motions tables increased from 38% to 79% over the 5 year time span. Conclusion: The number of domestic and international sites irradiating the head and neck and lung phantoms continues to increase and the pass rates remained constant. These end-to-end QA tests continue to be a crucial part of clinical trial credentialing and institution quality assurance. This investigation was supported by IROC grant CA180803 awarded by the NCI.

  16. SU-F-T-262: Commissioning Varian Portal Dosimetry for EPID-Based Patient Specific QA in a Non-Aria Environment

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, M; Knutson, N [Rhode Island Hospital, Providence RI (United States); University of Rhode Island, Kingston, RI (United States); University of Massachusetts Lowell, Lowell, MA (United States); Herrington, J [University of Rhode Island, Kingston, RI (United States); Price, M [Rhode Island Hospital, Providence RI (United States); University of Rhode Island, Kingston, RI (United States); Alpert Medical School of Brown University, Providence, RI (United States)

    2016-06-15

    Purpose: Development of an in-house program facilitates a workflow that allows Electronic Portal Imaging Device (EPID) patient specific quality assurance (QA) measurements to be acquired and analyzed in the Portal Dosimetry Application (Varian Medical Systems, Palo Alto, CA) using a non-Aria Record and Verify (R&V) system (MOSAIQ, Elekta, Crawley, UK) to deliver beams in standard clinical treatment mode. Methods: Initial calibration of an in-house software tool includes characterization of EPID dosimetry parameters by importing DICOM images of varying delivered MUs to determine linear mapping factors in order to convert image pixel values to Varian-defined Calibrated Units (CU). Using this information, the Portal Dose Image Prediction (PDIP) algorithm was commissioned by converting images of various field sizes to output factors using the Eclipse Scripting Application Programming Interface (ESAPI) and converting a delivered configuration fluence to absolute dose units. To verify the algorithm configuration, an integrated image was acquired, exported directly from the R&V client, automatically converted to a compatible, calibrated dosimetric image, and compared to a PDIP calculated image using Varian’s Portal Dosimetry Application. Results: For two C-Series and one TrueBeam Varian linear accelerators, gamma comparisons (global 3% / 3mm) of PDIP algorithm predicted dosimetric images and images converted via the inhouse system demonstrated agreement for ≥99% of all pixels, exceeding vendor-recommended commissioning guidelines. Conclusion: Combinations of a programmatic image conversion tool and ESAPI allow for an efficient and accurate method of patient IMRT QA incorporating a 3rd party R&V system.

  17. Quality assurance (QA) program in BNCT. RBE of 7 NCT beams for intestinal crypt regeneration in mice

    International Nuclear Information System (INIS)

    John, Gueulette; De Coster, Blanche-Marie; Wambersie, Andre; Gregoire, Vincent; Rasmussen, Finn S.; Auterinen, Iiro; Binns, Peter; Blaumann, Herman; Matsumura, Akira; Liu Hongming

    2006-01-01

    The epithermal neutron beams presently used for Neutron Capture Therapy (NCT) differ substantially in their composition (relative contribution of the different dose components to the total dose), in their dose rate (depending on the power of the reactor) as well as in their general feature (e.g. beam delivery system). Each of these elements might alter significantly the biological effectiveness of the beams. Therefore, the Relative Biological Effectiveness (RBE) of 7 NCT beams was intercompared, for a reference biological system (crypt regeneration in mice) and under well-defined irradiation conditions. This type of experiments - which should facilitate the exchange of radiobiological/clinical information - should take part of the Quality Assurance (QA) procedure of all NCT beams. (author)

  18. Final Hanford Site Transuranic (TRU) Waste Characterization QA Project Plan

    International Nuclear Information System (INIS)

    GREAGER, T.M.

    2000-01-01

    The Quality Assurance Project Plan (QAPjP) has been prepared for waste characterization activities to be conducted by the Transuranic (TRU) Project at the Hanford Site to meet requirements set forth in the Waste Isolation Pilot Plan (WIPP) Hazardous Waste Facility Permit, 4890139088-TSDF, Attachment B, including Attachments B1 through B6 (WAP) (DOE, 1999a). The QAPjP describes the waste characterization requirements and includes test methods, details of planned waste sampling and analysis, and a description of the waste characterization and verification process. In addition, the QAPjP includes a description of the quality assurance/quality control (QA/QC) requirements for the waste characterization program. Before TRU waste is shipped to the WIPP site by the TRU Project, all applicable requirements of the QAPjP shall be implemented. Additional requirements necessary for transportation to waste disposal at WIPP can be found in the ''Quality Assurance Program Document'' (DOE 1999b) and HNF-2600, ''Hanford Site Transuranic Waste Certification Plan.'' TRU mixed waste contains both TRU radioactive and hazardous components, as defined in the WLPP-WAP. The waste is designated and separately packaged as either contact-handled (CH) or remote-handled (RH), based on the radiological dose rate at the surface of the waste container. RH TRU wastes are not currently shipped to the WIPP facility

  19. Design of a QA method to characterize submillimeter-sized PBS beam properties using a 2D ionization chamber array

    Science.gov (United States)

    Lin, Yuting; Bentefour, Hassan; Flanz, Jacob; Kooy, Hanne; Clasie, Benjamin

    2018-05-01

    Pencil beam scanning (PBS) periodic quality assurance (QA) programs ensure the beam delivered to patients is within technical specifications. Two critical specifications for PBS delivery are the beam width and position. The aim of this study is to investigate whether a 2D ionization chamber array, such as the MatriXX detector (IBA Dosimetry, Schwarzenbruck, Germany), can be used to characterize submillimeter-sized PBS beam properties. The motivation is to use standard equipment, which may have pixel spacing coarser than the pencil beam size, and simplify QA workflow. The MatriXX pixels are cylindrical in shape with 4.5 mm diameter and are spaced 7.62 mm from center to center. Two major effects limit the ability of using the MatriXX to measure the spot position and width accurately. The first effect is that too few pixels sample the Gaussian shaped pencil beam profile and the second effect is volume averaging of the Gaussian profile over the pixel sensitive volumes. We designed a method that overcomes both limitations and hence enables the use of the MatriXX to characterize sub-millimeter-sized PBS beam properties. This method uses a cross-like irradiation pattern that is designed to increase the number of sampling data points and a modified Gaussian fitting technique to correct for volume averaging effects. Detector signals were calculated in this study and random noise and setup errors were added to simulate measured data. With the techniques developed in this work, the MatriXX detector can be used to characterize the position and width of sub-millimeter, σ  =  0.7 mm, sized pencil beams with uncertainty better than 3% relative to σ. With the irradiation only covering 60% of the MatriXX, the position and width of σ  =  0.9 mm sized pencil beams can be determined with uncertainty better than 3% relative to σ. If one were to not use a cross-like irradiation pattern, then the position and width of σ  =  3.6 mm sized pencil beams

  20. Review of Quality Assurance in SKB's Repository Research Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hicks, T.W. [Galson Sciences Ltd, 5 Grosvenor House, Melton Road, Oakham(United Kingdom)

    2007-01-15

    SKB is preparing licence applications for a spent nuclear fuel encapsulation plant and repository which will be supported by the SR-Site safety report. A separate safety report, SR-Can, has been produced by SKB in preparation for the SR-Site report. SKI is in the process of reviewing the SR-Can safety report. In preparation for this review, and with a view to building confidence in SKB's research activities and understanding SKB's handling of data and other information, SKI has examined SKB's application of QA measures in the management and conduct of repository research and development projects that support the SR-Can safety assessment. These preliminary investigations will serve to support the preparation of more detailed quality and technical audits of SKB's repository safety assessment after the submission of a licence application. SKI's approach to this QA review is based on the consideration of quality-affecting aspects of a selection of SKB's research and development activities. As part of this review, SKI identified the need to examine quality-related aspects of some of the many experiments and investigations that form part of SKB's repository research programme. This report presents the findings of such a review, focusing on experiments concerned with the properties and performance of the engineered barrier system. First, in order to establish a broad understanding of QA requirements for repository scientific investigations, QA procedures implemented in the management of research and development activities for the low-level radioactive waste repository near Drigg in the UK and the Waste Isolation Pilot Plant and Yucca Mountain repository projects in the US were studied. The QA procedures for experiments and tests undertaken in these projects were compared with those implemented by SKB. Key findings are: QA programmes have been implemented for each repository development programme in response to regulatory requirements

  1. Development of JAEA sorption database (JAEA-SDB). Update of data evaluation functions and sorption/QA data

    International Nuclear Information System (INIS)

    Tachi, Yukio; Suyama, Tadahiro; Ochs, Michael; Ganter, Charlotte

    2011-03-01

    Sorption and diffusion of radionuclides in buffer materials (bentonite) and rocks are the key processes in the safe geological disposal of radioactive waste, because migration of radionuclides in this barrier is expected to be diffusion-controlled and retarded by sorption processes. It is therefore necessary to understand the sorption and diffusion processes and develop database compiling reliable data and mechanistic/predictive models, so that reliable parameters can be set under a variety of geochemical conditions relevant to performance assessment (PA). For this purpose, Japan Atomic Energy Agency (JAEA) has developed databases of sorption and diffusion parameters in buffer materials (bentonite) and rocks. These sorption and diffusion databases (SDB/DDB) were firstly developed as an important basis for the H12 PA of high-level radioactive waste disposal, and have been provided through the Web. JAEA has been continuing to improve and update the SDB/DDB in view of potential future data needs, focusing on assuring the desired quality level and testing the usefulness of the databases for possible applications to PA-related parameter setting. The present report focuses on developing and updating of the sorption database (JAEA-SDB) as basis of integrated approach for PA-related K d setting. This includes an overview of database structure, contents and functions including additional data evaluation function focusing on multi-parameter dependence, operating method, PA-related applications of the web-based JAEA-SDB. K d data and their QA results are updated by focusing our recent activities on the K d setting and mechanistic model development. As a result, 4,250 K d data from 32 references are added, total K d values in the JAEA-SDB are about 28,540. The QA/classified K d data are about 39% for all K d data in JAEA-SDB. The updated JAEA-SDB is expected to make it possible to obtain quick overview of the available data, and to have suitable access to the respective data

  2. Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans.

    Science.gov (United States)

    McKenzie, Elizabeth M; Balter, Peter A; Stingo, Francesco C; Jones, Jimmy; Followill, David S; Kry, Stephen F

    2014-12-01

    The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference

  3. SU-E-T-746: The Use of Radiochromic Film Analyzed with Three Channel Dosimetry as a Secondary Patient-Specific QA Tool for Small SBRT Fields

    International Nuclear Information System (INIS)

    Hadsell, M; Holcombe, C; Chin, E; Hsu, A

    2015-01-01

    Introduction: As diagnostic techniques become more sensitive and targeting methods grow in accuracy, target volumes continue to shrink and SBRT becomes more prevalent. Due to this fact, patient-specific QA must also enhance resolution and accuracy in order to verify dose delivery in these volumes. It has been suggested that when measuring small fields at least two separate detectors be used to verify delivered dose. Therefore, we have instituted a secondary patient QA verification for small (<3cm) SBRT fields using Gafchromic EBT2 film. Methods: Films were cross-calibrated using a Farmer chamber in plastic water at reference conditions as defined by TG-51. Films were scanned, and an RGB calibration curve was created according to best practices published by Ashland, Inc. Four SBRT cases were evaluated both with the Scandidos Delta4 and with EBT2 films sandwiched in plastic water. Raw values obtained from the film were converted to dose using an in-house algorithm employing all three color channels to increase accuracy and dosimetric range. Gamma and dose profile comparisons to Eclipse dose calculations were obtained using RIT and compared to values obtained with the Delta4. Results: Film gamma pass rates at 2% and 2mm were similar to those obtained with the Delta4. However, dose difference histograms showed better absolute dose agreement, with the average mean film dose agreeing with calculation to 0.3% and the Delta4 only agreeing to 3.1% across the cases. Additionally, films provided more resolution than the Delta4 and thus their dose profiles better succeeded in diagnosing dose calculation inaccuracies. Conclusion: We believe that the implementation of secondary patient QA using EBT2 film analyzed with all three color channels is an invaluable tool for evaluation of small SBRT fields. Furthermore, we have shown that this method can sometimes provide a more detailed and faithful reproduction of plan dose than the Delta4

  4. Consumers' Use of UMLS Concepts on Social Media: Diabetes-Related Textual Data Analysis in Blog and Social Q&A Sites.

    Science.gov (United States)

    Park, Min Sook; He, Zhe; Chen, Zhiwei; Oh, Sanghee; Bian, Jiang

    2016-11-24

    The widely known terminology gap between health professionals and health consumers hinders effective information seeking for consumers. The aim of this study was to better understand consumers' usage of medical concepts by evaluating the coverage of concepts and semantic types of the Unified Medical Language System (UMLS) on diabetes-related postings in 2 types of social media: blogs and social question and answer (Q&A). We collected 2 types of social media data: (1) a total of 3711 blogs tagged with "diabetes" on Tumblr posted between February and October 2015; and (2) a total of 58,422 questions and associated answers posted between 2009 and 2014 in the diabetes category of Yahoo! Answers. We analyzed the datasets using a widely adopted biomedical text processing framework Apache cTAKES and its extension YTEX. First, we applied the named entity recognition (NER) method implemented in YTEX to identify UMLS concepts in the datasets. We then analyzed the coverage and the popularity of concepts in the UMLS source vocabularies across the 2 datasets (ie, blogs and social Q&A). Further, we conducted a concept-level comparative coverage analysis between SNOMED Clinical Terms (SNOMED CT) and Open-Access Collaborative Consumer Health Vocabulary (OAC CHV)-the top 2 UMLS source vocabularies that have the most coverage on our datasets. We also analyzed the UMLS semantic types that were frequently observed in our datasets. We identified 2415 UMLS concepts from blog postings, 6452 UMLS concepts from social Q&A questions, and 10,378 UMLS concepts from the answers. The medical concepts identified in the blogs can be covered by 56 source vocabularies in the UMLS, while those in questions and answers can be covered by 58 source vocabularies. SNOMED CT was the dominant vocabulary in terms of coverage across all the datasets, ranging from 84.9% to 95.9%. It was followed by OAC CHV (between 73.5% and 80.0%) and Metathesaurus Names (MTH) (between 55.7% and 73.5%). All of the social

  5. SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Han, B; Xing, L; Wang, L

    2016-01-01

    Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient

  6. Optimal density assignment to 2D diode array detector for different dose calculation algorithms in patient specific VMAT QA

    International Nuclear Information System (INIS)

    Park, So Yeon; Park, Jong Min; Choi, Chang Heon; Chun, MinSoo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In

    2017-01-01

    The purpose of this study is to assign an appropriate density to virtual phantom for 2D diode array detector with different dose calculation algorithms to guarantee the accuracy of patient-specific QA. Ten VMAT plans with 6 MV photon beam and ten VMAT plans with 15 MV photon beam were selected retrospectively. The computed tomography (CT) images of MapCHECK2 with MapPHAN were acquired to design the virtual phantom images. For all plans, dose distributions were calculated for the virtual phantoms with four different materials by AAA and AXB algorithms. The four materials were polystyrene, 455 HU, Jursinic phantom, and PVC. Passing rates for several gamma criteria were calculated by comparing the measured dose distribution with calculated dose distributions of four materials. For validation of AXB modeling in clinic, the mean percentages of agreement in the cases of dose difference criteria of 1.0% and 2.0% for 6 MV were 97.2%±2.3%, and 99.4%±1.1%, respectively while those for 15 MV were 98.5%±0.85% and 99.8%±0.2%, respectively. In the case of 2%/2 mm, all mean passing rates were more than 96.0% and 97.2% for 6 MV and 15 MV, respectively, regardless of the virtual phantoms of different materials and dose calculation algorithms. The passing rates in all criteria slightly increased for AXB as well as AAA when using 455 HU rather than polystyrene. The virtual phantom which had a 455 HU values showed high passing rates for all gamma criteria. To guarantee the accuracy of patent-specific VMAT QA, each institution should fine-tune the mass density or HU values of this device

  7. Optimal density assignment to 2D diode array detector for different dose calculation algorithms in patient specific VMAT QA

    Energy Technology Data Exchange (ETDEWEB)

    Park, So Yeon; Park, Jong Min; Choi, Chang Heon; Chun, MinSoo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-03-15

    The purpose of this study is to assign an appropriate density to virtual phantom for 2D diode array detector with different dose calculation algorithms to guarantee the accuracy of patient-specific QA. Ten VMAT plans with 6 MV photon beam and ten VMAT plans with 15 MV photon beam were selected retrospectively. The computed tomography (CT) images of MapCHECK2 with MapPHAN were acquired to design the virtual phantom images. For all plans, dose distributions were calculated for the virtual phantoms with four different materials by AAA and AXB algorithms. The four materials were polystyrene, 455 HU, Jursinic phantom, and PVC. Passing rates for several gamma criteria were calculated by comparing the measured dose distribution with calculated dose distributions of four materials. For validation of AXB modeling in clinic, the mean percentages of agreement in the cases of dose difference criteria of 1.0% and 2.0% for 6 MV were 97.2%±2.3%, and 99.4%±1.1%, respectively while those for 15 MV were 98.5%±0.85% and 99.8%±0.2%, respectively. In the case of 2%/2 mm, all mean passing rates were more than 96.0% and 97.2% for 6 MV and 15 MV, respectively, regardless of the virtual phantoms of different materials and dose calculation algorithms. The passing rates in all criteria slightly increased for AXB as well as AAA when using 455 HU rather than polystyrene. The virtual phantom which had a 455 HU values showed high passing rates for all gamma criteria. To guarantee the accuracy of patent-specific VMAT QA, each institution should fine-tune the mass density or HU values of this device.

  8. Review process and quality assurance in the EBR-II probabilistic risk assessment

    International Nuclear Information System (INIS)

    Roglans, J.; Hill, D.J.; Ragland, W.A.

    1992-01-01

    A Probabilistic Risk Assessment (PRA) of the Experimental Breeder Reactor II (EBR-II), a Department of Energy (DOE) Category A reactor, has recently been completed at Argonne National Laboratory (ANL). Within the scope of the ANL QA Programs, a QA Plan specifically for the EBR-II PRA was developed. The QA Plan covered all aspects of the PRA development, with emphasis on the procedures for document and software control, and the internal and external review process. The effort spent in the quality assurance tasks for the EBR-II PRA has reciprocated by providing acceptance of the work and confidence in the quality of the results

  9. Monte Carlo-based QA for IMRT of head and neck cancers

    Science.gov (United States)

    Tang, F.; Sham, J.; Ma, C.-M.; Li, J.-S.

    2007-06-01

    It is well-known that the presence of large air cavity in a dense medium (or patient) introduces significant electronic disequilibrium when irradiated with megavoltage X-ray field. This condition may worsen by the possible use of tiny beamlets in intensity-modulated radiation therapy (IMRT). Commercial treatment planning systems (TPSs), in particular those based on the pencil-beam method, do not provide accurate dose computation for the lungs and other cavity-laden body sites such as the head and neck. In this paper we present the use of Monte Carlo (MC) technique for dose re-calculation of IMRT of head and neck cancers. In our clinic, a turn-key software system is set up for MC calculation and comparison with TPS-calculated treatment plans as part of the quality assurance (QA) programme for IMRT delivery. A set of 10 off-the-self PCs is employed as the MC calculation engine with treatment plan parameters imported from the TPS via a graphical user interface (GUI) which also provides a platform for launching remote MC simulation and subsequent dose comparison with the TPS. The TPS-segmented intensity maps are used as input for the simulation hence skipping the time-consuming simulation of the multi-leaf collimator (MLC). The primary objective of this approach is to assess the accuracy of the TPS calculations in the presence of air cavities in the head and neck whereas the accuracy of leaf segmentation is verified by fluence measurement using a fluoroscopic camera-based imaging device. This measurement can also validate the correct transfer of intensity maps to the record and verify system. Comparisons between TPS and MC calculations of 6 MV IMRT for typical head and neck treatments review regional consistency in dose distribution except at and around the sinuses where our pencil-beam-based TPS sometimes over-predicts the dose by up to 10%, depending on the size of the cavities. In addition, dose re-buildup of up to 4% is observed at the posterior nasopharyngeal

  10. The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry.

    Science.gov (United States)

    Wong, J H D; Knittel, T; Downes, S; Carolan, M; Lerch, M L F; Petasecca, M; Perevertaylo, V L; Metcalfe, P; Jackson, M; Rosenfeld, A B

    2011-03-01

    Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. The DMG is an array of 128 phosphor implanted n+ strips on a p-type Si wafer. The sensitive area defined by a single n+ strip is 20 x 2000 microm2. The Si wafer is 375 microm thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S(cp)) of the SRS cones. Comparisons were made with the EBT2 film and standard S(cp) values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. The dose per pulse dependency of the DMG was found to be DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. The DMG was investigated for dose per pulse and angular dependency. Its application to SRS/SRT delivery verification was demonstrated. The DMG with its high spatial resolution and real time capability allows measurement of dose profiles for cone

  11. Redesigning Radiotherapy Quality Assurance: Opportunities to Develop an Efficient, Evidence-Based System to Support Clinical Trials—Report of the National Cancer Institute Work Group on Radiotherapy Quality Assurance

    International Nuclear Information System (INIS)

    Bekelman, Justin E.; Deye, James A.; Vikram, Bhadrasain; Bentzen, Soren M.; Bruner, Deborah; Curran, Walter J.; Dignam, James; Efstathiou, Jason A.; FitzGerald, T.J.; Hurkmans, Coen; Ibbott, Geoffrey S.; Lee, J. Jack; Merchant, Thomas E.; Michalski, Jeff; Palta, Jatinder R.; Simon, Richard; Ten Haken, Randal K.; Timmerman, Robert; Tunis, Sean; Coleman, C. Norman

    2012-01-01

    Purpose: In the context of national calls for reorganizing cancer clinical trials, the National Cancer Institute sponsored a 2-day workshop to examine challenges and opportunities for optimizing radiotherapy quality assurance (QA) in clinical trial design. Methods and Materials: Participants reviewed the current processes of clinical trial QA and noted the QA challenges presented by advanced technologies. The lessons learned from the radiotherapy QA programs of recent trials were discussed in detail. Four potential opportunities for optimizing radiotherapy QA were explored, including the use of normal tissue toxicity and tumor control metrics, biomarkers of radiation toxicity, new radiotherapy modalities such as proton beam therapy, and the international harmonization of clinical trial QA. Results: Four recommendations were made: (1) to develop a tiered (and more efficient) system for radiotherapy QA and tailor the intensity of QA to the clinical trial objectives (tiers include general credentialing, trial-specific credentialing, and individual case review); (2) to establish a case QA repository; (3) to develop an evidence base for clinical trial QA and introduce innovative prospective trial designs to evaluate radiotherapy QA in clinical trials; and (4) to explore the feasibility of consolidating clinical trial QA in the United States. Conclusion: Radiotherapy QA can affect clinical trial accrual, cost, outcomes, and generalizability. To achieve maximum benefit, QA programs must become more efficient and evidence-based.

  12. Redesigning Radiotherapy Quality Assurance: Opportunities to Develop an Efficient, Evidence-Based System to Support Clinical Trials-Report of the National Cancer Institute Work Group on Radiotherapy Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Bekelman, Justin E., E-mail: bekelman@uphs.upenn.edu [University of Pennsylvania, Philadelphia, Pennsylvania (United States); Deye, James A.; Vikram, Bhadrasain [National Cancer Institute, Bethesda, Maryland (United States); Bentzen, Soren M. [University of Wisconsin, Madison, Wisconsin (United States); Bruner, Deborah [University of Pennsylvania, Philadelphia, Pennsylvania (United States); Curran, Walter J. [Emory University, Atlanta, Georgia (United States); Dignam, James [University of Chicago, Chicago, Illinois (United States); Efstathiou, Jason A. [Massachusetts General Hospital, Boston, Massachusetts (United States); FitzGerald, T.J. [University of Massachusetts, Boston, Massachusetts (United States); Hurkmans, Coen [European Organization for Research and Treatment of Cancer, Brussels (Belgium); Ibbott, Geoffrey S.; Lee, J. Jack [University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Merchant, Thomas E. [St. Jude Children' s Research Hospital, Memphis, Tennessee (United States); Michalski, Jeff [University of Washington, St. Louis, Missouri (United States); Palta, Jatinder R. [University of Florida, Miami, Florida (United States); Simon, Richard [National Institutes of Health, Bethesda, Maryland (United States); Ten Haken, Randal K. [University of Michigan, Ann Arbor, Michigan (United States); Timmerman, Robert [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Tunis, Sean [Center for Medical Technology Policy, Baltimore, Maryland (United States); Coleman, C. Norman [National Cancer Institute, Bethesda, Maryland (United States); and others

    2012-07-01

    Purpose: In the context of national calls for reorganizing cancer clinical trials, the National Cancer Institute sponsored a 2-day workshop to examine challenges and opportunities for optimizing radiotherapy quality assurance (QA) in clinical trial design. Methods and Materials: Participants reviewed the current processes of clinical trial QA and noted the QA challenges presented by advanced technologies. The lessons learned from the radiotherapy QA programs of recent trials were discussed in detail. Four potential opportunities for optimizing radiotherapy QA were explored, including the use of normal tissue toxicity and tumor control metrics, biomarkers of radiation toxicity, new radiotherapy modalities such as proton beam therapy, and the international harmonization of clinical trial QA. Results: Four recommendations were made: (1) to develop a tiered (and more efficient) system for radiotherapy QA and tailor the intensity of QA to the clinical trial objectives (tiers include general credentialing, trial-specific credentialing, and individual case review); (2) to establish a case QA repository; (3) to develop an evidence base for clinical trial QA and introduce innovative prospective trial designs to evaluate radiotherapy QA in clinical trials; and (4) to explore the feasibility of consolidating clinical trial QA in the United States. Conclusion: Radiotherapy QA can affect clinical trial accrual, cost, outcomes, and generalizability. To achieve maximum benefit, QA programs must become more efficient and evidence-based.

  13. Redesigning Radiotherapy Quality Assurance: Opportunities to Develop an Efficient, Evidence-Based System to Support Clinical Trials

    Science.gov (United States)

    Bekelman, Justin E.; Deye, James A.; Vikram, Bhadrasain; Bentzen, Soren M.; Bruner, Deborah; Curran, Walter J.; Dignam, James; Efstathiou, Jason A.; FitzGerald, T. J.; Hurkmans, Coen; Ibbott, Geoffrey S.; Lee, J. Jack; Merchant, Timothy E.; Michalski, Jeff; Palta, Jatinder R.; Simon, Richard; Ten Haken, Randal K.; Timmerman, Robert; Tunis, Sean; Coleman, C. Norman; Purdy, James

    2012-01-01

    Background In the context of national calls for reorganizing cancer clinical trials, the National Cancer Institute (NCI) sponsored a two day workshop to examine the challenges and opportunities for optimizing radiotherapy quality assurance (QA) in clinical trial design. Methods Participants reviewed the current processes of clinical trial QA and noted the QA challenges presented by advanced technologies. Lessons learned from the radiotherapy QA programs of recent trials were discussed in detail. Four potential opportunities for optimizing radiotherapy QA were explored, including the use of normal tissue toxicity and tumor control metrics, biomarkers of radiation toxicity, new radiotherapy modalities like proton beam therapy, and the international harmonization of clinical trial QA. Results Four recommendations were made: 1) Develop a tiered (and more efficient) system for radiotherapy QA and tailor intensity of QA to clinical trial objectives. Tiers include (i) general credentialing, (ii) trial specific credentialing, and (iii) individual case review; 2) Establish a case QA repository; 3) Develop an evidence base for clinical trial QA and introduce innovative prospective trial designs to evaluate radiotherapy QA in clinical trials; and 4) Explore the feasibility of consolidating clinical trial QA in the United States. Conclusion Radiotherapy QA may impact clinical trial accrual, cost, outcomes and generalizability. To achieve maximum benefit, QA programs must become more efficient and evidence-based. PMID:22425219

  14. Gating treatment delivery QA based on a surrogate motion analysis

    International Nuclear Information System (INIS)

    Chojnowski, J.; Simpson, E.

    2011-01-01

    Full text: To develop a methodology to estimate intrafractional target position error during a phase-based gated treatment. Westmead Cancer Care Centre is using respiratory correlated phase-based gated beam delivery in the treatment of lung cancer. The gating technique is managed by the Varian Real-time Position Management (RPM) system, version 1.7.5. A 6-dot block is placed on the abdomen of the patient and acts as a surrogate for the target motion. During a treatment session, the motion of the surrogate can be recorded by RPM application. Analysis of the surrogate motion file by in-house developed software allows the intrafractional error of the treatment session to be computed. To validate the computed error, a simple test that involves the introduction of deliberate errors is performed. Errors of up to 1.1 cm are introduced to a metal marker placed on a surrogate using the Varian Breathing Phantom. The moving marker was scanned in prospective mode using a GE Lightspeed 16 CT scanner. Using the CT images, a difference of the marker position with and without introduced errors is compared to the calculated errors based on the surrogate motion. The average and standard deviation of a difference between calculated target position errors and measured introduced artificial errors of the marker position is 0.02 cm and 0.07 cm respectively. Conclusion The calculated target positional error based on surrogate motion analysis provides a quantitative measure of intrafractional target positional errors during treatment. Routine QA for gated treatment using surrogate motion analysis is relatively quick and simple.

  15. QA REVIEWS: HOW THEY DIFFER FROM PEER REVIEWS

    Science.gov (United States)

    Research papers and reports written by scientists and engineers in the United States Environmental Protection Agency are reviewed by the agency's quality assurance staff. EPA papers and reports are subjected to peer reviews that check for the validity of conclusions and the gener...

  16. Science Education and Teacher Effectiveness: Implications of the Next Generation Science Standards (NGSS): Q&A with Chris Wilson, Ph.D., and Jody Bintz, M.S. REL Mid-Atlantic Teacher Effectiveness Webinar Series

    Science.gov (United States)

    Regional Educational Laboratory Mid-Atlantic, 2014

    2014-01-01

    This webinar explored how the Next Generation Science Standards (NGSS) provide an instructional framework to support professional growth and inform teacher evaluation systems for science instruction. This Q&A addressed the questions participants had for Dr. Wilson and Jody Bintz following the webinar. The webinar recording and PowerPoint…

  17. SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

    International Nuclear Information System (INIS)

    Wang, L; Nelson, B

    2014-01-01

    Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA

  18. SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

    Energy Technology Data Exchange (ETDEWEB)

    Wagar, M; Friesen, S; Lyatskaya, Y; O’Farrell, D; Bhagwat, M [Dana Farber/Brigham and Women’s Hospital, Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

  19. Dominique Thomas, Générations djihadistes. Al-Qaïda – État islamique, histoire d’une lutte fratricide

    OpenAIRE

    Blanc, Théo

    2017-01-01

    La multiplication des attentats en Europe est souvent décrite comme la conséquence de l’hégémonie du groupe État islamique (EI) sur la mouvance djihadiste. Pourtant, le massacre de Charlie Hebdo le 7 janvier 2015 par des militants d’Al-Qaïda (AQ) vient rappeler avec force que l’organisation initiatrice du djihad global est loin d’avoir été éclipsée. En réalité, AQ et EI se livrent une bataille idéologique et stratégique pour le « monopole du djihadisme » (p. 153). Leur divergence sur les fina...

  20. VMAT QA: Measurement-guided 4D dose reconstruction on a patient

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Opp, Daniel; Robinson, Joshua; Wolf, Theresa K.; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States); Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Live Oak Technologies LLC, Kirkwood, Missouri 63122 (United States); Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2012-07-15

    Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of

  1. Quality Assurance Issues in Conducting Multi-Institutional Advanced Technology Clinical Trials

    International Nuclear Information System (INIS)

    Purdy, James A.

    2008-01-01

    The National Cancer Institute-sponsored Advanced Technology Quality Assurance (QA) Consortium, which consisted of the Image-Guided Therapy QA Center, Radiation Therapy Oncology Group, Radiological Physics Center, Quality Assurance Review Center, and Resource Center for Emerging Technologies, has pioneered the development of an infrastructure and QA method for advanced technology clinical trials that requires volumetric digital data submission of a protocol patient's treatment plan and verification data. In particular, the Image-Guided Therapy QA Center has nearly 15 years experience in facilitating QA review for Radiation Therapy Oncology Group advanced technology clinical trials. This QA process includes (1) a data integrity review for completeness of protocol required elements, the format of data, and possible data corruption, and recalculation of dose-volume histograms; (2) a review of compliance with target volume and organ-at-risk contours by study chairs; and (3) a review of dose prescription and dose heterogeneity compliance by the Radiation Therapy Oncology Group Headquarters Dosimetry Group or the Radiological Physics Center dosimetrists (for brachytherapy protocols). This report reviews the lessons learned and the QA challenges presented by the use of advanced treatment modalities in clinical trials requiring volumetric digital data submission

  2. MO-E-217A-01: Contrast-Enhanced Spectral Mammography - Physical Aspects and QA.

    Science.gov (United States)

    Yaffe, M; Hill, M

    2012-06-01

    To describe the current state of dual energy contrast-enhanced digital mammography, to discuss those aspects of its operation that require evaluation or monitoring and to propose elements of a program for quality assurance of such systems. The principles of dual-energy contrast imaging will be discussed and tools and techniques for assessment of performance will be described. Many of the elements affecting image quality and dose performance in digital mammography (eg noise, system linearity, consistency of x-ray output and detector performance, artifacts) remain important. In addition, the ability to register images can influence the resultant image quality. The maintenance of breast compression thickness during the imaging procedure and calibration of the system to allow quantification of iodine in the breast represent new challenges to quality assurance. CESM provides a means of acquiring new information regarding tumor angiogenesis and may reveal some cancers that will not be detectable on digital mammography. It may also better demonstrate the extent of disease. The medical physicist must understand the dependence of image quality on physical factors. Implementation of a relevant QA program will be required if the promise of this new modality is to be delivered. © 2012 American Association of Physicists in Medicine.

  3. An independent check of treatment plan, prescription and dose calculation as a QA procedure

    International Nuclear Information System (INIS)

    Duggan, Lisa; Kron, Tomas; Howlett, Stephen; Skov, Annette; O'Brien, Peter

    1997-01-01

    In many radiotherapy centres where planning for external beam treatments is performed by radiation therapists, the treatment sheet and its calculations are independently checked by staff from a different educational background, typically a radiotherapy physicist. The benefits of this practice were evaluated in a radiotherapy department with two linear accelerators, one combined superficial-orthovoltage unit and one telecaesium unit. Within the 19 months of the investigation period, 2328 checks were performed on the treatment sheets of 1579 patients. In six cases, errors in excess of 5% were detected, which if uncorrected, could potentially have affected local tumour control or caused normal tissue complications. It was found that an independent check of treatment sheets assists in keeping these errors as low as can be achievable in clinical practice, and suggests that treatment sheet checking and in vivo dosimetry play a complementary role in this aim. Independent treatment sheet checking is an important quality assurance (QA) activity, with additional advantages such as improved communication in the department, education of staff and in vivo dosimetry targeting. Therefore the advantages of the procedure seem to outweigh the additional workload of approximately 0.3 full-time staff per 1000 patients per year

  4. SU-F-T-587: Quality Assurance of Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT) for Patient Specific Plans: A Comparison Between MATRIXX and Delta4 QA Devices

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, YC; Lu, SH; Chen, LH; Kuo, SH; Wang, CW [National Taiwan University Hospital, Taipei City, Taiwan (China)

    2016-06-15

    Purpose: Patient-specific quality assurance (QA) is necessary to accurately deliver high dose radiation to the target, especially for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT). Unlike previous 2 dimensional (D) array QA devices, Delta{sup 4} can verify the dose delivery in 3D. In this study, the difference between calculated and measured dose distribution was compared with two QA devices (MATRIXX and Delta{sup 4}) to evaluate the delivery accuracy. Methods: Twenty-seven SRS/SBRT plans with VMAT were verified with point-dose and dose-map analysis. We use an ion chamber (A1SL, 0.053cc) for point-dose measurement. For verification of the dose map, the differences between the calculated and measured doses were analyzed with a gamma index using MATRIXX and Delta{sup 4} devices. The passing criteria for gamma evaluation were set at 3 mm for distance-to-agreement (DTA) and 3% for dose-difference. A gamma index less than 1 was defined as the verification passing the criteria and satisfying at least 95% of the points. Results: The mean prescribed dose and fraction was 40 ± 14.41 Gy (range: 16–60) and 10 ± 2.35 fractions (range: 1–8), respectively. In point dose analysis, the differences between the calculated and measured doses were all less than 5% (mean: 2.12 ± 1.13%; range: −0.55% to 4.45%). In dose-map analysis, the average passing rates were 99.38 ± 0.96% (range: 95.31–100%) and 100 ± 0.12% (range: 99.5%–100%) for MATRIXX and Delta{sup 4}, respectively. Even using criteria of 2%/2 mm, the passing rate of Delta{sup 4} was still more than 95% (mean: 99 ± 1.08%; range: 95.6%–100%). Conclusion: Both MATRIXX and Delta{sup 4} offer accurate and efficient verification for SRS/SBRT plans. The results measured by MATRIXX and Delta{sup 4} dosimetry systems are similar for SRS/SBRT performed with the VMAT technique.

  5. The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry

    International Nuclear Information System (INIS)

    Wong, J. H. D.; Knittel, T.; Downes, S.; Carolan, M.; Lerch, M. L. F.; Petasecca, M.; Perevertaylo, V. L.; Metcalfe, P.; Jackson, M.; Rosenfeld, A. B.

    2011-01-01

    Purpose: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. Methods: The DMG is an array of 128 phosphor implanted n + strips on a p-type Si wafer. The sensitive area defined by a single n + strip is 20x2000 μm 2 . The Si wafer is 375 μm thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S cp ) of the SRS cones. Comparisons were made with the EBT2 film and standard S cp values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. Results: The dose per pulse dependency of the DMG was found to be cp agrees very well with the standard data with an average difference of 1.2±1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. Conclusions: The DMG was investigated for dose per pulse and angular dependency. Its

  6. The IAEA Code of Practice on quality assurance, and quality assurance requirements and practices in Member States

    International Nuclear Information System (INIS)

    Raisic, N.

    1982-01-01

    The IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants and the corresponding Safety Guides are reviewed and compared with quality assurance (QA) practices in the IAEA Member States. The QA requirements stipulated by the Code place on the nuclear power plant owner the responsibility to establish an overall QA programme for the plant. In selecting the QA programme level for specific activities, the Code allows of a flexible approach but does not specify gradation in programme requirements. The Code is placing the burden of quality-achieving and quality-assuring functions on the task-performing organizations, namely the designers, manufacturers, constructors and plant operators. The plant owner provides for the management of the overall QA programme, surveillance of activities and verifications of the effectiveness of the constituent programmes of all project participants through programme audits and evaluations. The Code and the supporting Safety Guides are consistent with existing QA practices in Member States. However, certain differences exist, which are mainly expressed in the different QA functions assigned to the various organizations participating in the overall QA programme. Also, some Member States place more emphasis on redundant verification activities than on quality-achieving functions. Tendencies are also identified to grade the QA requirements in respect of items and activities, in accordance with some pre-established criteria. In an annex to the paper, QA practices in Member States participating in the Agency's Technical Review Committee on Quality Assurance (TRC-QA) are reviewed, indicating their similarities to and differences from the Code

  7. Study on the application of quality assurance in research and development

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyuk Il; Lim, Kap Soon; Lee, Young Keun; Lim, Nam Jin; Cho, Moon Seong; Choi, Se Jin; Won, Byung Chool; Kwon, Woo Ju; Lee, Jae Hyung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-12-01

    Application status of R and D QA system in advanced research organizations abroad was studied and related information were reviewed. On these bases, KAERI R and D QA system and detailed instructions for R and D projects were trained with the system. Especially for three of the five demo projects, project specific QA programs were developed in accordance with project types. Besides, the 1st Nuclear QA seminar and other events such as `Seminar on Adopting Quality Management in an R and D Environment` were held for the purpose of assisting QA implementation in demo projects as well as enhancing researchers` perceptions on QA. Based on these activities, measures for QA application in R and D were suggested, which include R and D QA document hierarchy, determination of the scope of QA application, and QA activities in project performance stage and appraisal stage. 4 tabs., 12 figs., 13 refs. (Author).

  8. Achievements and advantages of participation in the IAEA project RER 002/004/1999-2001 'QA/QC of Nuclear Analytical Techniques'

    International Nuclear Information System (INIS)

    Vata, Ion; Cincu, Em.

    2002-01-01

    The National Institute for Physics and Engineering 'Horia Hulubei' (IFIN-HH) decided in the late 1990s to start applying nuclear techniques in economy and social life on a routine scale; reaching this goal implied achieving first-rate analytical performances and complying with the QA/QC requirements, as detailed in the ISO 17025. The IAEA Project appeared in 1999 as the best opportunity and tool for our specialists to become familiar with the standard requirements and begin to implement them in their operations, thus further enabling them to apply for accreditation according to the international criteria. This report outlines the experience gained from the participation in the project. The accomplishments of the project are presented and the main difficulties are identified

  9. Transforming an EPA QA/R-2 quality management plan into an ISO 9002 quality management system.

    Science.gov (United States)

    Kell, R A; Hedin, C M; Kassakhian, G H; Reynolds, E S

    2001-01-01

    The Environmental Protection Agency's (EPA) Office of Emergency and Remedial Response (OERR) requires environmental data of known quality to support Superfund hazardous waste site projects. The Quality Assurance Technical Support (QATS) Program is operated by Shaw Environmental and Infrastructure, Inc. to provide EPA's Analytical Operations Center (AOC) with performance evaluation samples, reference materials, on-site laboratory auditing capabilities, data audits (including electronic media data audits), methods development, and other support services. The new QATS contract awarded in November 2000 required that the QATS Program become ISO 9000 certified. In a first for an EPA contractor, the QATS staff and management successfully transformed EPA's QA/R-2 type Quality Management Plan into a Quality Management System (QMS) that complies with the requirements of the internationally recognized ISO 9002 standard and achieved certification in the United States, Canada, and throughout Europe. The presentation describes how quality system elements of ISO 9002 were implemented on an already existing quality system. The psychological and organizational challenges of the culture change in QATS' day-to-day operations will be discussed for the benefit of other ISO 9000 aspirants.

  10. Laboratory QA/QC improvements for small drinking water systems at Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Turner, R.D.

    1995-12-01

    The Savannah River Site (SRS), a 310 square mile facility located near Aiken, S.C., is operated by Westinghouse Savannah River Company for the US Department of Energy. SRS has 28 separate drinking water systems with average daily demands ranging from 0.0002 to 0.5 MGD. All systems utilize treated groundwater. Until recently, the water laboratories for each system operated independently. As a result, equipment, reagents, chemicals, procedures, personnel, and quality control practices differed from location to location. Due to this inconsistency, and a lack of extensive laboratory OA/QC practices at some locations, SRS auditors were not confident in the accuracy of daily water quality analyses results. The Site`s Water Services Department addressed these concerns by developing and implementing a practical laboratory QA/QC program. Basic changes were made which can be readily adopted by most small drinking water systems. Key features of the program include: Standardized and upgraded laboratory instrumentation and equipment; standardized analytical procedures based on vendor manuals and site requirements; periodic accuracy checks for all instrumentation; creation of a centralized laboratory to perform metals digestions and chlorine colorimeter accuracy checks; off-site and on-site operator training; proper storage, inventory and shelf life monitoring for reagents and chemicals. This program has enhanced the credibility and accuracy of SRS drinking water system analyses results.

  11. Long term high resolution rainfall runoff observations for improved water balance uncertainty and database QA-QC in the Walnut Gulch Experimental Watershed.

    Science.gov (United States)

    Bitew, M. M.; Goodrich, D. C.; Demaria, E.; Heilman, P.; Kautz, M. A.

    2017-12-01

    Walnut Gulch is a semi-arid environment experimental watershed and Long Term Agro-ecosystem Research (LTAR) site managed by USDA-ARS Southwest Watershed Research Center for which high-resolution long-term hydro-climatic data are available across its 150 km2 drainage area. In this study, we present the analysis of 50 years of continuous hourly rainfall data to evaluate runoff control and generation processes for improving the QA-QC plans of Walnut Gulch to create high-quality data set that is critical for reducing water balance uncertainties. Multiple linear regression models were developed to relate rainfall properties, runoff characteristics and watershed properties. The rainfall properties were summarized to event based total depth, maximum intensity, duration, the location of the storm center with respect to the outlet, and storm size normalized to watershed area. We evaluated the interaction between the runoff and rainfall and runoff as antecedent moisture condition (AMC), antecedent runoff condition (ARC) and, runoff depth and duration for each rainfall events. We summarized each of the watershed properties such as contributing area, slope, shape, channel length, stream density, channel flow area, and percent of the area of retention stock ponds for each of the nested catchments in Walnut Gulch. The evaluation of the model using basic and categorical statistics showed good predictive skill throughout the watersheds. The model produced correlation coefficients ranging from 0.4-0.94, Nash efficiency coefficients up to 0.77, and Kling-Gupta coefficients ranging from 0.4 to 0.98. The model predicted 92% of all runoff generations and 98% of no-runoff across all sub-watersheds in Walnut Gulch. The regression model also indicated good potential to complement the QA-QC procedures in place for Walnut Gulch dataset publications developed over the years since the 1960s through identification of inconsistencies in rainfall and runoff relations.

  12. Quality Assurance for Operation of Nuclear Facilities

    International Nuclear Information System (INIS)

    Park, C. G.; Kwon, H. I.; Kim, K. H.; Oh, Y. W.; Lee, Y. G.; Ha, J. H.; Lim, N. J.

    2008-12-01

    This report describes QA activities performed within 'Quality Assurance for Nuclear facility project' and results thereof. Efforts were made to maintain and improve quality system of nuclear facilities. Varification activities whether quality system was implemented in compliance with requirements. QA department assisted KOLAS accredited testing and calibration laboratories, ISO 9001 quality system, establishment of QA programs for R and D, and carried out reviews and surveys for development of quality assurance technologies. Major items of this report are as follows : - Development and Improvement of QA Programs - QA Activities - Assessment of Effectiveness and Adequacy for QA Programs

  13. Basic principles of quality assurance

    International Nuclear Information System (INIS)

    Stauffer, M.

    1977-01-01

    After a brief review of the origin of the 'quality concept' and the historical development of quality assurance, questions such as 'what is QA' and 'why is QA so important in nuclear technology' as well as definitions and main requirements of relevant QA codes and standards are presented and discussed. By means of a project realization schematic, tasks, duties, responsibilities, and possible QA organigrammes as well as QA programme and manual requirements are explained and compared. From a QA point of view, it is shown that no basic difference exists between design and production or construction control activities. Special emphasis is layed upon active owner's participation in the implementation of QA programmes for NPP and the advantages offered are described and illustrated by typical examples. (RW) [de

  14. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  15. Judicial Review of Antitrust Decisions: Q&A

    Directory of Open Access Journals (Sweden)

    Roberto Giovagnoli

    2015-07-01

    Full Text Available The RIA/IAR asked several experts to give their opinion on the Italian system of judicial review of antitrust decisions and its compatibility with art. 6 of the ECHR following a set of common questions.

  16. Private animal health and welfare standards in quality assurance programmes: a review and proposed framework for critical evaluation.

    Science.gov (United States)

    More, S J; Hanlon, A; Marchewka, J; Boyle, L

    2017-06-24

    In recent years, 'private standards' in animal health and welfare have become increasingly common, and are often incorporated into quality assurance (QA) programmes. Here, we present an overview of the use of private animal health and welfare standards in QA programmes, and propose a generic framework to facilitate critical programme review. Private standards are being developed in direct response to consumer demand for QA, and offer an opportunity for product differentiation and a means to drive consumer choice. Nonetheless, a range of concerns have been raised, relating to the credibility of these standards, their potential as a discriminatory barrier to trade, the multiplicity of private standards that have been developed, the lack of consumer input and compliance costs. There is a need for greater scrutiny of private standards and of associated QA programmes. We propose a framework to clarify the primary programme goal(s) and measureable outputs relevant to animal health and welfare, the primary programme beneficiaries and to determine whether the programme is effective, efficient and transparent. This paper provides a theoretical overview, noting that this framework could be used as a tool directly for programme evaluation, or as a tool to assist with programme development and review. British Veterinary Association.

  17. Quality Assurance Program: Argonne peer review activities for the salt host-rock portion of the Civilian Radioactive Waste Management Program

    International Nuclear Information System (INIS)

    Edgar, D.E.

    1986-01-01

    This Quality Assurance (QA) Program sets forth the methods, controls, and procedures used to ensure that the results of Argonne National Laboratory's peer review activities are consistently of the highest quality and responsive to Salt Repository Project Office's needs and directives. Implementation of the QA procedures described herein establishes an operational framework so that task activities are traceable and the activities and decisions that influence the overall quality of the peer review process and results are fully documented. 56 refs., 5 figs., 6 tabs

  18. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

    International Nuclear Information System (INIS)

    Kim, Jung-in; Park, So-Yeon; Kim, Hak Jae; Kim, Jin Ho; Ye, Sung-Joon; Park, Jong Min

    2014-01-01

    To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam. Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman’s rank correlation coefficient (γ). The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8). Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively

  19. SU-E-P-02: Imaging and Radiation Oncology Core (IROC) Houston QA Center (RPC) Credentialing

    International Nuclear Information System (INIS)

    Amador, C; Keith, T; Nguyen, T; Molineu, A; Followill, D

    2014-01-01

    Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Methods: IROC Houston issues credentials for NCI sponsored study groups. Requirements for credentialing might include any combination of questionnaires, knowledge assessment forms, benchmarks, or phantom irradiations. Credentialing requirements for specific protocols can be found on IROC Houston's website (irochouston.mdanderson.org). The website also houses the credentialing status inquiry (CSI) form. Once an institution has reviewed the protocol's credentialing requirements, a CSI form should be completed and submitted to IROC Houston. This form is used both to request whether requirements have been met as well as to notify IROC Houston that the institution requests credentialing for a specific protocol. IROC Houston will contact the institution to discuss any delinquent requirements. Once the institution has met all requirements IROC Houston issues a credentialing letter to the institution and will inform study groups and other IROC offices of the credentials. Institutions can all phone the IROC Houston office to initiate credentialing or ask any credentialing related questions. Results: Since 2010 IROC has received 1313 credentialing status inquiry forms. We received 317 in 2010, 266 in 2011, 324 in 2012, and 406 in 2013. On average we receive 35 phone calls per week with multiple types of credentialing questions. Decisions regarding credentialing status are based on the protocol specifications and previous completed credentialing by the institution. In some cases, such as for general IMRT credentialing, up to 5 sites may be credentialed based on the credentialing of one main center. Each of these situations is handled individually. Conclusion: IROC Houston will issue radiation therapy credentials for the NCI trials in the National Clinical Trials Network. Credentialing requirements and the CSI form

  20. Radiochromic film for individual patient QA in extracranial stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Kron, T.; Clements, N.; Aarons, Y.; Dunn, L.; Chesson, B.; Miller, J.; Roozen, K.; Ball, D.

    2011-01-01

    Introduction: Modern radiotherapy is characterised by increasingly complex radiation delivery such as Intensity Modulated Radiation Therapy (IMRT) or extracranial stereotactic radiotherapy (ESR). It has become common practice to verify the delivery for each patient in IMRT, however, no such methods have been defined to date for ESR. It was the aim of the present work to develop a method to verify the dose distribution for ESR in a moving phantom using radiochromic film. Methods: Radiochromic film (ISP EBT2) was used in a cylindrical film cassette fitted into a QUASAR phantom (Modus Medical). The cassette can be moved forwards and backwards with motion patterns that can mimic the breathing of individual patients. The radiotherapy treatment plans of four patients were re-planned for the phantom. Between 8 and 10 radiation fields of 6 MV photons from a Varian Trilogy linear accelerator were used to deliver target doses between 18 and 26 Gy per fraction. In order to allow for measurements with EBT2 film all monitor units were divided by 3 or 4 resulting in maximum doses not exceeding 10 Gy. The film was evaluated using a transmission scan on an Epson Perfection V700 scanner with 50 dpi spatial resolution (3 colors, 48bit). A calibration curve was used to convert either the red or green component of the scan to dose. Results: Qualitative film analysis found no discernible discrepancies from planned isodose distributions in the stationary images. The dose distribution in the moving phantom was used successfully to confirm the appropriateness of the ITV construction in the planning process. Conclusions: We have developed a QA procedure that accounts for breathing patterns of individual patients in ESR for lung cancer. Radiochromic film was found to be easy to adapt to this process.

  1. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  2. Improvements to the subgroup option and the QA of MONK5W

    International Nuclear Information System (INIS)

    Grimshaw, D.; Davies, N.; Hutton, L.

    1988-10-01

    This report covers the changes that have been made to MONK5W since release 5A. These include an improved SUBGROUP treatment which removes the approximations inherent in previous versions of the code and which reduces the storage requirements which had previously made some calculations impossible to perform. A minor error has also been corrected which occurred when using P0 scattering with NOVICE data. Furthermore 13 minor code changes have been made which are mainly additional user error traps, or user hidden changes to improve the code probability. However 3 were minor bug corrections: an incorrect output format; an incorrect calculation of the standard deviation on the flux and an overwriting problem for large storage burnup calculations. Finally, one of the largest and most varied verification and validation exercises ever to be performed with MONK5W has been done. This exercise used the MONK5W QA database which has been previously reported. It contains a hundred test cases which have been specially designed to provide a testbed and some method of determining the range of the validity of the MONK5W package. The code has been improved so that it can be applied more successfully to a wider range of problems. Together with the vigorous testing of the code, MONK5W is now in a better shape than it has ever been. The improvements are important because users can use the code in circumstances where previously it could not be used. The stringent testing is important because users now demand a better quality assessed package than was once acceptable. (author)

  3. SU-E-T-644: QuAArC: A 3D VMAT QA System Based On Radiochromic Film and Monte Carlo Simulation of Log Files

    Energy Technology Data Exchange (ETDEWEB)

    Barbeiro, A.R.; Ureba, A.; Baeza, J.A.; Jimenez-Ortega, E.; Plaza, A. Leal [Universidad de Sevilla, Departamento de Fisiologia Medica y Biofisica, Seville (Spain); Linares, R. [Hospital Infanta Luisa, Servicio de Radiofisica, Seville (Spain); Mateos, J.C.; Velazquez, S. [Hospital Universitario Virgen del Rocio, Servicio de Radiofisica, Seville (Spain)

    2015-06-15

    Purpose: VMAT involves two main sources of uncertainty: one related to the dose calculation accuracy, and the other linked to the continuous delivery of a discrete calculation. The purpose of this work is to present QuAArC, an alternative VMAT QA system to control and potentially reduce these uncertainties. Methods: An automated MC simulation of log files, recorded during VMAT treatment plans delivery, was implemented in order to simulate the actual treatment parameters. The linac head models and the phase-space data of each Control Point (CP) were simulated using the EGSnrc/BEAMnrc MC code, and the corresponding dose calculation was carried out by means of BEAMDOSE, a DOSXYZnrc code modification. A cylindrical phantom was specifically designed to host films rolled up at different radial distances from the isocenter, for a 3D and continuous dosimetric verification. It also allows axial and/or coronal films and point measurements with several types of ion chambers at different locations. Specific software was developed in MATLAB in order to process and evaluate the dosimetric measurements, which incorporates the analysis of dose distributions, profiles, dose difference maps, and 2D/3D gamma index. It is also possible to obtain the experimental DVH reconstructed on the patient CT, by an optimization method to find the individual contribution corresponding to each CP on the film, taking into account the total measured dose, and the corresponding CP dose calculated by MC. Results: The QuAArC system showed high reproducibility of measurements, and consistency with the results obtained with the commercial system implemented in the verification of the evaluated treatment plans. Conclusion: A VMAT QA system based on MC simulation and high resolution dosimetry with film has been developed for treatment verification. It shows to be useful for the study of the real VMAT capabilities, and also for linac commissioning and evaluation of other verification devices.

  4. Review of data mining applications for quality assessment in manufacturing industry: support vector machines

    Directory of Open Access Journals (Sweden)

    Rostami Hamidey

    2015-01-01

    Full Text Available In many modern manufacturing industries, data that characterize the manufacturing process are electronically collected and stored in databases. Due to advances in data collection systems and analysis tools, data mining (DM has widely been applied for quality assessment (QA in manufacturing industries. In DM, the choice of technique to be used in analyzing a dataset and assessing the quality depend on the understanding of the analyst. On the other hand, with the advent of improved and efficient prediction techniques, there is a need for an analyst to know which tool performs better for a particular type of dataset. Although a few review papers have recently been published to discuss DM applications in manufacturing for QA, this paper provides an extensive review to investigate the application of a special DM technique, namely support vector machine (SVM to deal with QA problems. This review provides a comprehensive analysis of the literature from various points of view as DM concepts, data preprocessing, DM applications for each quality task, SVM preliminaries, and application results. Summary tables and figures are also provided besides to the analyses. Finally, conclusions and future research directions are provided.

  5. SU-F-BRE-13: Replacing Pre-Treatment Phantom QA with 3D In-Vivo Portal Dosimetry for IMRT Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Stroom, J; Vieira, S; Greco, C [Champalimaud Foundation, Lisbon (Portugal); Olaciregui-Ruiz, I; Rozendaal, R; Herk, M van [The Netherlands Cancer Institute, Amsterdam, North Holland (Netherlands); Moser, E [Champalimaud Foundation, Lisbon, Lisbon (Portugal)

    2014-06-15

    Purpose: Pre-treatment QA of individual treatment plans requires costly linac time and physics effort. Starting with IMRT breast treatments, we aim to replace pre-treatment QA with in-vivo portal dosimetry. Methods: Our IMRT breast cancer plans are routinely measured using the ArcCheck device (SunNuclear). 2D-Gamma analysis is performed with 3%/3mm criteria and the percentage of points with gamma<1 (nG1) is calculated within the 50% isodose surface. Following AAPM recommendations, plans with nG1<90% are approved; others need further inspection and might be rejected. For this study, we used invivo portal dosimetry (IPD) to measure the 3D back-projected dose of the first three fractions for IMRT breast plans. Patient setup was online corrected before for all measured fractions. To reduce patient related uncertainties, the three IPD results were averaged and 3D-gamma analysis was applied with abovementioned criteria . For a subset of patients, phantom portal dosimetry (PPD) was also performed on a slab phantom. Results: Forty consecutive breast patients with plans that fitted the EPID were analysed. The average difference between planned and IPD dose in the reference point was −0.7+/−1.6% (1SD). Variation in nG1 between the 3 invivo fractions was about 6% (1SD). The average nG1 for IPD was 89+/−6%, worse than ArcCheck (95+/−3%). This can be explained by patient related factors such as changes in anatomy and/or model deficiencies due to e.g. inhomogeneities. For the 20 cases with PPD, mean nG1 was equal to ArcCheck values, which indicates that the two systems are equally accurate. These data therefore suggest that proper criteria for 3D invivo verification of breast treatments should be nG1>80% instead of nG1>90%, which, for our breast cases, would result in 5% (2/40) further inspections. Conclusion: First-fraction in-vivo portal dosimetry using new gamma-evaluation criteria will replace phantom measurements in our institution, saving resources and yielding 3D

  6. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams".

    Science.gov (United States)

    Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B

    2017-01-01

    The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of

  7. Clinical trials radiotherapy treatment plan review software : is this the first quantified assessment

    International Nuclear Information System (INIS)

    Hatton, J.A.; Cornes, D.A.

    2011-01-01

    Full text: Clinical trials require robust quality assurance (QA) procedures to ensure commonality of all treatments, with independent reviews to assess compliance with trial protocols. All clinical trials tools, including QA software, require testing for validity and reliability. enabling inter- and intra-trial comparison. Unlike clinical radiotherapy treatment planning (RTP) systems, review software has no published guidelines. This study describes the design and development of a test suite to quantify the performance of review software in TROG clinical trials. Test areas are image handling and reconstruction; geometric accuracy; dosimetric accuracy; dose-volume histogram (DVH) calculation; display of plan parameters. TROG have developed tests for commissioning plan review software, assessed with SWAN 2.3, and CMS Elekta FocalPro. While image handling tests were based on published guidelines for RTP systems, dosimetric tests used the TROG QA case review requirements. Treatment plans represented systems of all manufacturers (Pinnacle, Eclipse, Xio and Oncentra) used in Australasian centres. The test suite identified areas for SW A software development, including the DVH algorithm, changed to reduce calculation time. Results, in Fig. I, for known volumes of varying shapes and sizes, demonstrate differences between SWAN 2.1 and 2.3 when compared with Eclipse. Liaison with SWAN programmers enabled re-instatement of 2.1 algorithm. The test suite has quantified the RTP review software, prioritised areas for development with the programmers, and improved the user experience.

  8. Algorithm theoretical baseline for formaldehyde retrievals from S5P TROPOMI and from the QA4ECV project

    Directory of Open Access Journals (Sweden)

    I. De Smedt

    2018-04-01

    Full Text Available On board the Copernicus Sentinel-5 Precursor (S5P platform, the TROPOspheric Monitoring Instrument (TROPOMI is a double-channel, nadir-viewing grating spectrometer measuring solar back-scattered earthshine radiances in the ultraviolet, visible, near-infrared, and shortwave infrared with global daily coverage. In the ultraviolet range, its spectral resolution and radiometric performance are equivalent to those of its predecessor OMI, but its horizontal resolution at true nadir is improved by an order of magnitude. This paper introduces the formaldehyde (HCHO tropospheric vertical column retrieval algorithm implemented in the S5P operational processor and comprehensively describes its various retrieval steps. Furthermore, algorithmic improvements developed in the framework of the EU FP7-project QA4ECV are described for future updates of the processor. Detailed error estimates are discussed in the light of Copernicus user requirements and needs for validation are highlighted. Finally, verification results based on the application of the algorithm to OMI measurements are presented, demonstrating the performances expected for TROPOMI.

  9. SU-F-T-315: Comparative Studies of Planar Dose with Different Spatial Resolution for Head and Neck IMRT QA

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, T; Koo, T [Hallym University Medical Center, Chuncheon, Gangwon (Korea, Republic of)

    2016-06-15

    Purpose: To quantitatively investigate the planar dose difference and the γ value between the reference fluence map with the 1 mm detector-to-detector distance and the other fluence maps with less spatial resolution for head and neck intensity modulated radiation (IMRT) therapy. Methods: For ten head and neck cancer patients, the IMRT quality assurance (QA) beams were generated using by the commercial radiation treatment planning system, Pinnacle3 (ver. 8.0.d Philips Medical System, Madison, WI). For each beam, ten fluence maps (detector-to-detector distance: 1 mm to 10 mm by 1 mm) were generated. The fluence maps with larger than 1 mm detector-todetector distance were interpolated using MATLAB (R2014a, the Math Works,Natick, MA) by four different interpolation Methods: for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. These interpolated fluence maps were compared with the reference one using the γ value (criteria: 3%, 3 mm) and the relative dose difference. Results: As the detector-to-detector distance increases, the dose difference between the two maps increases. For the fluence map with the same resolution, the cubic spline interpolation and the bicubic interpolation are almost equally best interpolation methods while the nearest neighbor interpolation is the worst.For example, for 5 mm distance fluence maps, γ≤1 are 98.12±2.28%, 99.48±0.66%, 99.45±0.65% and 82.23±0.48% for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. For 7 mm distance fluence maps, γ≤1 are 90.87±5.91%, 90.22±6.95%, 91.79±5.97% and 71.93±4.92 for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. Conclusion: We recommend that the 2-dimensional detector array with high spatial resolution should be used as an IMRT QA tool and that the measured fluence maps should be interpolated using by the cubic spline interpolation or the

  10. Reinforcing of QA/QC programs in radiotherapy departments in Croatia: Results of treatment planning system verification

    Energy Technology Data Exchange (ETDEWEB)

    Jurković, Slaven; Švabić, Manda; Diklić, Ana; Smilović Radojčić, Đeni; Dundara, Dea [Clinic for Radiotherapy and Oncology, Physics Division, University Hospital Rijeka, Rijeka (Croatia); Kasabašić, Mladen; Ivković, Ana [Department for Radiotherapy and Oncology, University Hospital Osijek, Osijek (Croatia); Faj, Dario, E-mail: dariofaj@mefos.hr [Department of Physics, School of Medicine, University of Osijek, Osijek (Croatia)

    2013-04-01

    Implementation of advanced techniques in clinical practice can greatly improve the outcome of radiation therapy, but it also makes the process much more complex with a lot of room for errors. An important part of the quality assurance program is verification of treatment planning system (TPS). Dosimetric verifications in anthropomorphic phantom were performed in 4 centers where new systems were installed. A total of 14 tests for 2 photon energies and multigrid superposition algorithms were conducted using the CMS XiO TPS. Evaluation criteria as specified in the International Atomic Energy Agency Technical Reports Series (IAEA TRS) 430 were employed. Results of measurements are grouped according to the placement of the measuring point and the beam energy. The majority of differences between calculated and measured doses in the water-equivalent part of the phantom were in tolerance. Significantly more out-of-tolerance values were observed in “nonwater-equivalent” parts of the phantom, especially for higher-energy photon beams. This survey was done as a part of continuous effort to build up awareness of quality assurance/quality control (QA/QC) importance in the Croatian radiotherapy community. Understanding the limitations of different parts of the various systems used in radiation therapy can systematically improve quality as well.

  11. Quality assurance for nuclear power plants. Proceedings of an international symposium organized by the IAEA and held in Paris, 11-15 May 1981

    International Nuclear Information System (INIS)

    1982-01-01

    The International Symposium on Quality Assurance for Nuclear Power Plants, organized by the International Atomic Energy Agency, was held in Paris from 11 to 15 May 1981. The main objectives of the symposium were the following: (1) To review the present requirements and practices in implementing quality assurance (QA) in nuclear power projects in Member States; (2) To identify the existing similarities and differences and to highlight those aspects of QA in Member States which are controversial and in need of harmonization; (3) To assess the practical use of the established requirements and recommendations of the IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants and the relevant Safety Guides. Because of the interdisciplinary nature of QA and the rather broad scope of its activities, only seven topics of QA were selected for review and discussion. They included, besides a general comparison of QA requirements and practices in IAEA Member States, methodologies for the selection of appropriate QA programme levels for specific items and services; the role of independent inspection in verification activities; economic aspects of QA; manpower requirements for QA in nuclear power projects; training, qualification and certification of QA personnel; and specific aspects of the implementation of QA in countries embarking on nuclear power projects. Each of these topics was treated in a separate session. These Proceedings include the full text of all invited papers and of a large part of the contributed papers. The contributed papers that are not published in full are represented by abstracts in the session summaries. The summaries of the sessions as prepared by the working groups appear at the end of the appropriate sessions. The holding of an international symposium on quality assurance appeared well timed. The importance of QA in the nuclear industry is constantly growing with the increasing requirements for safety and availability of nuclear

  12. SU-F-T-260: Using Portal Image Device for Pre-Treatment QA in Volumetric Modulated Arc Plans with Flattening Filter Free (FFF) Beams

    Energy Technology Data Exchange (ETDEWEB)

    Qu, H; Qi, P; Yu, N; Xia, P [The Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: To implement and validate a method of using electronic portal image device (EPID) for pre-treatment quality assurance (QA) of volumetric modulated arc therapy (VMAT) plans using flattering filter free (FFF) beams for stereotactic body radiotherapy (SBRT). Methods: On Varian Edge with 6MV FFF beam, open field (from 2×2 cm to 20×20 cm) EPID images were acquired with 200 monitor unit (MU) at the image device to radiation source distance of 150cm. With 10×10 open field and calibration unit (CU) provided by vendor to EPID image pixel, a dose conversion factor was determined by dividing the center dose calculated from the treatment planning system (TPS) to the corresponding CU readout on the image. Water phantom measured beam profile and the output factors for various field sizes were further correlated to those of EPID images. The dose conversion factor and correction factors were then used for converting the portal images to the planner dose distributions of clinical fields. A total of 28 VMAT fields of 14 SBRT plans (8 lung, 2 prostate, 2 liver and 2 spine) were measured. With 10% low threshold cutoff, the delivered dose distributions were compared to the reference doses calculated in water phantom from the TPS. A gamma index analysis was performed for the comparison in percentage dose difference/distance-to-agreement specifications. Results: The EPID device has a linear response to the open fields with increasing MU. For the clinical fields, the gamma indices between the converted EPID dose distributions and the TPS calculated 2D dose distributions were 98.7%±1.1%, 94.0%±3.4% and 70.3%±7.7% for the criteria of 3%/3mm, 2%/2mm and 1%/1mm, respectively. Conclusion: Using a portal image device, a high resolution and high accuracy portal dosimerty was achieved for pre-treatment QA verification for SBRT VMAT plans with FFF beams.

  13. Quality assurance in performance assessments

    Energy Technology Data Exchange (ETDEWEB)

    Maul, P.R.; Watkins, B.M.; Salter, P.; Mcleod, R [QuantiSci Ltd, Henley-on-Thames (United Kingdom)

    1999-01-01

    Following publication of the Site-94 report, SKI wishes to review how Quality Assurance (QA) issues could be treated in future work both in undertaking their own Performance Assessment (PA) calculations and in scrutinising documents supplied by SKB (on planning a repository for spent fuels in Sweden). The aim of this report is to identify the key QA issues and to outline the nature and content of a QA plan which would be suitable for SKI, bearing in mind the requirements and recommendations of relevant standards. Emphasis is on issues which are specific to Performance Assessments for deep repositories for radioactive wastes, but consideration is also given to issues which need to be addressed in all large projects. Given the long time over which the performance of a deep repository system must be evaluated, the demonstration that a repository is likely to perform satisfactorily relies on the use of computer-generated model predictions of system performance. This raises particular QA issues which are generally not encountered in other technical areas (for instance, power station operations). The traceability of the arguments used is a key QA issue, as are conceptual model uncertainty, and code verification and validation; these were all included in the consideration of overall uncertainties in the Site-94 project. Additionally, issues which are particularly relevant to SKI include: How QA in a PA fits in with the general QA procedures of the organisation undertaking the work. The relationship between QA as applied by the regulator and the implementor of a repository development programme. Section 2 introduces the discussion of these issues by reviewing the standards and guidance which are available from national and international organisations. This is followed in Section 3 by a review of specific issues which arise from the Site-94 exercise. An outline procedure for managing QA issues in SKI is put forward as a basis for discussion in Section 4. It is hoped that

  14. Quality assurance in performance assessments

    International Nuclear Information System (INIS)

    Maul, P.R.; Watkins, B.M.; Salter, P.; Mcleod, R

    1999-01-01

    Following publication of the Site-94 report, SKI wishes to review how Quality Assurance (QA) issues could be treated in future work both in undertaking their own Performance Assessment (PA) calculations and in scrutinising documents supplied by SKB (on planning a repository for spent fuels in Sweden). The aim of this report is to identify the key QA issues and to outline the nature and content of a QA plan which would be suitable for SKI, bearing in mind the requirements and recommendations of relevant standards. Emphasis is on issues which are specific to Performance Assessments for deep repositories for radioactive wastes, but consideration is also given to issues which need to be addressed in all large projects. Given the long time over which the performance of a deep repository system must be evaluated, the demonstration that a repository is likely to perform satisfactorily relies on the use of computer-generated model predictions of system performance. This raises particular QA issues which are generally not encountered in other technical areas (for instance, power station operations). The traceability of the arguments used is a key QA issue, as are conceptual model uncertainty, and code verification and validation; these were all included in the consideration of overall uncertainties in the Site-94 project. Additionally, issues which are particularly relevant to SKI include: How QA in a PA fits in with the general QA procedures of the organisation undertaking the work. The relationship between QA as applied by the regulator and the implementor of a repository development programme. Section 2 introduces the discussion of these issues by reviewing the standards and guidance which are available from national and international organisations. This is followed in Section 3 by a review of specific issues which arise from the Site-94 exercise. An outline procedure for managing QA issues in SKI is put forward as a basis for discussion in Section 4. It is hoped that

  15. Developing cross-sectoral quality assurance for cataract surgery in the statutory quality assurance program of the German health care system: Experiences and lessons learned.

    Science.gov (United States)

    Bramesfeld, Anke; Pauletzki, Jürgen; Behrenz, Lars; Szecsenyi, Joachim; Willms, Gerald; Broge, Björn

    2015-08-01

    Since 2001, statutory external quality assurance (QA) for hospital care has been in place in the German health system. In 2009, the decision was taken to expand it to cross-sectoral procedures. This novel and unprecedented form of national QA aims at (1) making the quality procedures comparable that are provided both in inpatient and outpatient care, (2) following-up outcomes of hospital care after patients' discharge and (3) measuring the quality of complex treatment chains across interfaces. As a pioneer procedure a QA procedure in cataract surgery QA was developed. Using this as an example, challenges of cross-sectoral QA are highlighted. These challenges relate, in particular, to three technical problems: triggering cases for documentation, following-up patients' after hospital discharge, and the burden of documentation in outpatient care. These problems resulted finally in the haltering of the development of the QA procedure. However, the experiences gained with this first development of cross-sectoral QA inspired the reorientation and further development of the field in Germany. Future cross-sectoral QA will rigorously aim at keeping burden of documentation small. It will draw data for QA mainly at three sources: routine data, patient surveys and peer reviews using indicators. Policy implications of this reorientation are discussed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. SU-E-P-02: Imaging and Radiation Oncology Core (IROC) Houston QA Center (RPC) Credentialing

    Energy Technology Data Exchange (ETDEWEB)

    Amador, C; Keith, T; Nguyen, T; Molineu, A; Followill, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-01

    Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Methods: IROC Houston issues credentials for NCI sponsored study groups. Requirements for credentialing might include any combination of questionnaires, knowledge assessment forms, benchmarks, or phantom irradiations. Credentialing requirements for specific protocols can be found on IROC Houston's website (irochouston.mdanderson.org). The website also houses the credentialing status inquiry (CSI) form. Once an institution has reviewed the protocol's credentialing requirements, a CSI form should be completed and submitted to IROC Houston. This form is used both to request whether requirements have been met as well as to notify IROC Houston that the institution requests credentialing for a specific protocol. IROC Houston will contact the institution to discuss any delinquent requirements. Once the institution has met all requirements IROC Houston issues a credentialing letter to the institution and will inform study groups and other IROC offices of the credentials. Institutions can all phone the IROC Houston office to initiate credentialing or ask any credentialing related questions. Results: Since 2010 IROC has received 1313 credentialing status inquiry forms. We received 317 in 2010, 266 in 2011, 324 in 2012, and 406 in 2013. On average we receive 35 phone calls per week with multiple types of credentialing questions. Decisions regarding credentialing status are based on the protocol specifications and previous completed credentialing by the institution. In some cases, such as for general IMRT credentialing, up to 5 sites may be credentialed based on the credentialing of one main center. Each of these situations is handled individually. Conclusion: IROC Houston will issue radiation therapy credentials for the NCI trials in the National Clinical Trials Network. Credentialing requirements

  17. Nuclear Energy Research Initiative Project No. 02 103 Innovative Low Cost Approaches to Automating QA/QC of Fuel Particle Production Using On Line Nondestructive Methods for Higher Reliability Final Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Salahuddin; Batishko, Charles R.; Flake, Matthew; Good, Morris S.; Mathews, Royce; Morra, Marino; Panetta, Paul D.; Pardini, Allan F.; Sandness, Gerald A.; Tucker, Brian J.; Weier, Dennis R.; Hockey, Ronald L.; Gray, Joseph N.; Saurwein, John J.; Bond, Leonard J.; Lowden, Richard A.; Miller, James H.

    2006-02-28

    This Nuclear Energy Research Initiative (NERI) project was tasked with exploring, adapting, developing and demonstrating innovative nondestructive test methods to automate nuclear coated particle fuel inspection so as to provide the United States (US) with necessary improved and economical Quality Assurance and Control (QA/QC) that is needed for the fuels for several reactor concepts being proposed for both near term deployment [DOE NE & NERAC, 2001] and Generation IV nuclear systems. Replacing present day QA/QC methods, done manually and in many cases destructively, with higher speed automated nondestructive methods will make fuel production for advanced reactors economically feasible. For successful deployment of next generation reactors that employ particle fuels, or fuels in the form of pebbles based on particles, extremely large numbers of fuel particles will require inspection at throughput rates that do not significantly impact the proposed manufacturing processes. The focus of the project is nondestructive examination (NDE) technologies that can be automated for production speeds and make either: (I) On Process Measurements or (II) In Line Measurements. The inspection technologies selected will enable particle “quality” qualification as a particle or group of particles passes a sensor. A multiple attribute dependent signature will be measured and used for qualification or process control decisions. A primary task for achieving this objective is to establish standard signatures for both good/acceptable particles and the most problematic types of defects using several nondestructive methods.

  18. Prospective Qualitative and Quantitative Analysis of Real-Time Peer Review Quality Assurance Rounds Incorporating Direct Physical Examination for Head and Neck Cancer Radiation Therapy.

    Science.gov (United States)

    Cardenas, Carlos E; Mohamed, Abdallah S R; Tao, Randa; Wong, Andrew J R; Awan, Mussadiq J; Kuruvila, Shirly; Aristophanous, Michalis; Gunn, G Brandon; Phan, Jack; Beadle, Beth M; Frank, Steven J; Garden, Adam S; Morrison, William H; Fuller, Clifton D; Rosenthal, David I

    2017-07-01

    Our department has a long-established comprehensive quality assurance (QA) planning clinic for patients undergoing radiation therapy (RT) for head and neck cancer. Our aim is to assess the impact of a real-time peer review QA process on the quantitative and qualitative radiation therapy plan changes in the era of intensity modulated RT (IMRT). Prospective data for 85 patients undergoing head and neck IMRT who presented at a biweekly QA clinic after simulation and contouring were collected. A standard data collection form was used to document alterations made during this process. The original pre-QA clinical target volumes (CTVs) approved by the treating-attending physicians were saved before QA and compared with post-QA consensus CTVs. Qualitative assessment was done according to predefined criteria. Dice similarity coefficients (DSC) and other volume overlap metrics were calculated for each CTV level and were used for quantitative comparison. Changes are categorized as major, minor, and trivial according to the degree of overlap. Patterns of failure were analyzed and correlated to plan changes. All 85 patients were examined by at least 1 head and neck subspecialist radiation oncologist who was not the treating-attending physician; 80 (94%) were examined by ≥3 faculty members. New clinical findings on physical examination were found in 12 patients (14%) leading to major plan changes. Quantitative DSC analysis revealed significantly better agreement in CTV1 (0.94 ± 0.10) contours than in CTV2 (0.82 ± 0.25) and CTV3 (0.86 ± 0.2) contours (P=.0002 and P=.03, respectively; matched-pair Wilcoxon test). The experience of the treating-attending radiation oncologist significantly affected DSC values when all CTV levels were considered (P=.012; matched-pair Wilcoxon text). After a median follow-up time of 38 months, only 10 patients (12%) had local recurrence, regional recurrence, or both, mostly in central high-dose areas. Comprehensive peer review planning

  19. [Development of quality assurance/quality control web system in radiotherapy].

    Science.gov (United States)

    Okamoto, Hiroyuki; Mochizuki, Toshihiko; Yokoyama, Kazutoshi; Wakita, Akihisa; Nakamura, Satoshi; Ueki, Heihachi; Shiozawa, Keiko; Sasaki, Koji; Fuse, Masashi; Abe, Yoshihisa; Itami, Jun

    2013-12-01

    Our purpose is to develop a QA/QC (quality assurance/quality control) web system using a server-side script language such as HTML (HyperText Markup Language) and PHP (Hypertext Preprocessor), which can be useful as a tool to share information about QA/QC in radiotherapy. The system proposed in this study can be easily built in one's own institute, because HTML can be easily handled. There are two desired functions in a QA/QC web system: (i) To review the results of QA/QC for a radiotherapy machine, manuals, and reports necessary for routinely performing radiotherapy through this system. By disclosing the results, transparency can be maintained, (ii) To reveal a protocol for QA/QC in one's own institute using pictures and movies relating to QA/QC for simplicity's sake, which can also be used as an educational tool for junior radiation technologists and medical physicists. By using this system, not only administrators, but also all staff involved in radiotherapy, can obtain information about the conditions and accuracy of treatment machines through the QA/QC web system.

  20. Exploratory Shaft Facility quality assurance impact evaluation

    International Nuclear Information System (INIS)

    1987-08-01

    This report addresses the impact of the quality assurance practices used for the Exploratory Shaft Facility (ESF) design, and construction in licensing as part of the repository. Acceptance criteria used for evaluating the suitability of ESF QA practices are based on documents that had not been invoked for repository design or construction activities at the time of this evaluation. This report identifies the QA practices necessary for ESF design and construction licensability. A review and evaluation of QA practices for ESF design and construction resulted in the following conclusions. QA practices were found to be acceptable with a few exceptions. QA practices for construction activities were found to be insufficiently documented in implementing procedures to allow a full and effective evaluation for licensing purposes. Recommendations are provided for mitigating impacts to ensure compatibility of the QA practices with those considered necessary for repository licensing. 8 refs., 3 tabs

  1. Development of quality measures for monitoring and improving care in gastroenterology.

    Science.gov (United States)

    Germansky, Katharine A; Leffler, Daniel A

    2011-06-01

    Over the past decade, most quality assurance (QA) efforts in gastroenterology have been aimed at endoscopy. Endoscopic quality improvement was the rational area to begin QA work in gastroenterology due to the relatively acute nature of complications and the high volume of procedures performed. While endoscopy is currently the focus of most quality assurance (QA) measures in gastroenterology, more recent efforts have begun to address clinical gastroenterology practices both in the outpatient and inpatient settings. Clinical outpatient and inpatient gastroenterology is laden with areas where standardization could benefit patient care. While data and experience in clinical gastroenterology QA is relatively limited, it is clear that inconsistent use of guidelines and practice variations in gastroenterology can lead to lower quality care. In this review, we review a variety of areas in clinical gastroenterology where existing guidelines and published data suggest both the need and practicality of active QA measures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Development of energy-efficient comfortable ventilation systems with air quality guided volume flow control and continuous monitoring of the window opening status. Part 1. Use of the LuQaS triple sensor for air quality guided volume flow control of mechanical ventilation systems in domestic buildings. Research project; Entwicklung energieeffizienter Komfortlueftungsanlagen mit luftqualitaetsgefuehrter Volumenstromregelung und kontinuierlicher Erfassung des Fensteroeffnungszustandes. Teilbericht 1. Einsatz des LuQaS-Triple-Sensors zur luftqualitaetsgefuehrten Volumenstromregelung von mechanischen Lueftungsanlagen in Wohngebaeuden. Forschungsprojekt

    Energy Technology Data Exchange (ETDEWEB)

    Grossklos, Marc; Ebel, Witta; Knissel, Jens

    2011-05-15

    The report presents the preparatory work on the research project of the above title. The first chapter presents a status report on air quality monitoring inside rooms and evaluates the projects so far in which the LuQaS air quality sensor was used. The second chapter is a documentation of preliminary measurements using the LuQaS sensor in two passive residential buildings and several individual measurements for sensor calibration. It was found that in apartments with mechanical ventilation, the sensor reflects the user activities; further, the measured values indicate signal changes also in the off-air of the building, so that control via central sensors in the ventilation and off-air systems appears feasible. The third chapter discusses control strategies for air quality control. Apart from a discussion of control unit types, operating regimes, methods to determine rated values, and additional control functions, the effects of threshold value control with different threshold limit values and volume flow changes on the air quality of a model building was simulated. The results prove the expectation that the air quality inside a building will be influenced positively by air quality control. Theoretical investigations of the DrD method will be presented in another part-report of the project.

  3. Quality assurance system for conventional island erection of Daya Day Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Zhongliang, Shi; Suozhi, Wu; Xiangke, Meng [Shandong Electric Power Construction Corp. Nuclear Power Construction Company (China)

    1994-12-01

    The process concerning the establishment, operation and perfection of Quality Assurance System (QA system) experienced by Shandong Electric Power Construction Corporation, Nuclear Power Construction Company (SEPC-NPCC) during the implementation of Conventional Island Erection (CIE) in Daya Bay Nuclear Power Plant is introduced. Apart from systematic description of the principle for working out QA programme and QA procedures and their main contents, it is also detailed, on a combination of theory with practice basis, how the major departments constituting the QA system such as Quality Assurance, Quality Control, Construction and Administration and Business Departments have made fruitful efforts as per the individual responsibility for ensuring the work quality and having in mind the principles specified by QA programme and the requirements of QA procedures. As a result of the reasonable combination of the 3 crucial points and the 4 essential elements of the QA system, high quality of CI erection has been realized. The importance of quality supervision and management review by the owner and upper levels of authorities for ensuring effective operation of QA system is affirmed. The practical experience of CIE project proves that the strict inspection/surveillance on all activities and service affecting quality carried out by QA Department independent of project management and QC Dept, independent of construction management are of quite importance for ensuring the project quality. (4 tabs.).

  4. Quality assurance system for conventional island erection of Daya Day Nuclear Power Plant

    International Nuclear Information System (INIS)

    Shi Zhongliang; Wu Suozhi; Meng Xiangke

    1994-12-01

    The process concerning the establishment, operation and perfection of Quality Assurance System (QA system) experienced by Shandong Electric Power Construction Corporation, Nuclear Power Construction Company (SEPC-NPCC) during the implementation of Conventional Island Erection (CIE) in Daya Bay Nuclear Power Plant is introduced. Apart from systematic description of the principle for working out QA programme and QA procedures and their main contents, it is also detailed, on a combination of theory with practice basis, how the major departments constituting the QA system such as Quality Assurance, Quality Control, Construction and Administration and Business Departments have made fruitful efforts as per the individual responsibility for ensuring the work quality and having in mind the principles specified by QA programme and the requirements of QA procedures. As a result of the reasonable combination of the 3 crucial points and the 4 essential elements of the QA system, high quality of CI erection has been realized. The importance of quality supervision and management review by the owner and upper levels of authorities for ensuring effective operation of QA system is affirmed. The practical experience of CIE project proves that the strict inspection/surveillance on all activities and service affecting quality carried out by QA Department independent of project management and QC Dept, independent of construction management are of quite importance for ensuring the project quality. (4 tabs.)

  5. A Functional Model of Quality Assurance for Psychiatric Hospitals and Corresponding Staffing Requirements.

    Science.gov (United States)

    Kamis-Gould, Edna; And Others

    1991-01-01

    A model for quality assurance (QA) in psychiatric hospitals is described. Its functions (general QA, utilization review, clinical records, evaluation, management information systems, risk management, and infection control), subfunctions, and corresponding staffing requirements are reviewed. This model was designed to foster standardization in QA…

  6. Depositional and diagenetic processes of Qa Khanna playa, North Jordan basaltic plateau, Jordan

    Science.gov (United States)

    Howari, F. M.; Banat, K. M.; Abu-Salha, Y. A.

    2010-09-01

    The present study explored mineral occurrences and sediment characteristics of playas from northern Jordan and explained depositional and diagenetic processes as reflected from bulk chemistry and sedimentary structures. Mudcracks of different sizes and shape patterns, laminations, intersediment vesicles, and bioturbation pipes are the main sedimentary structures. Plagioclase, olivine, orthopyroxene, nepheline and other opaque minerals are all of detrital origin, and are derived from the basaltic bedrocks surrounding the studied playa. Evaporites are very rare; they are represented only by trace amounts of gypsum. The identified clay minerals in the clay fraction of the studied sediments, arranged according to their decreasing abundances are palygorskite, illite, kaolinite, smectite and chlorite. The elemental abundances were tied to clay, CaCO 3 and nearby igneous rocks. The type of clay minerals, the high pH values of the studied sediments, and the considerable incorporation of Mg and K in palygorskite and illite respectively, may strongly reflect a high evaporative and alkaline environment under arid to semi-arid conditions in an ephemeral lake of the Qa Khanna. Concentrations and distributions of both major and trace elements are essentially controlled by the clay mineralogy and the calcium carbonate content; Ca is mainly incorporated in the CaCO 3, which is either generated authigenically or by aeolian deposition. Fe and K are incorporated and fixed by illite under an evaporative and alkaline environment. Mg is incorporated in palygorskite while Mn is adsorbed on various clay minerals. Sr substitutes for Ca in the aeolian CaCO 3 and its presence in the studied sediments is independent of the prevailing conditions during the playa evolution. Rb substitutes for K in illite under the prevailing chemical conditions in the studied playa.

  7. Expression and subcellular localization of the Qa-SNARE syntaxin17 in human eosinophils.

    Science.gov (United States)

    Carmo, Lívia A S; Dias, Felipe F; Malta, Kássia K; Amaral, Kátia B; Shamri, Revital; Weller, Peter F; Melo, Rossana C N

    2015-10-01

    SNARE members mediate membrane fusion during intracellular trafficking underlying innate and adaptive immune responses by different cells. However, little is known about the expression and function of these proteins in human eosinophils, cells involved in allergic, inflammatory and immunoregulatory responses. Here, we investigate the expression and distribution of the Qa-SNARE syntaxin17 (STX17) within human eosinophils isolated from the peripheral blood. Flow cytometry and a pre-embedding immunonanogold electron microscopy (EM) technique that combines optimal epitope preservation and secondary Fab-fragments of antibodies linked to 1.4 nm gold particles for optimal access to microdomains, were used to investigate STX17. STX17 was detected within unstimulated eosinophils. Immunogold EM revealed STX17 on secretory granules and on granule-derived vesiculotubular transport carriers (Eosinophil Sombrero Vesicles-EoSVs). Quantitative EM analyses showed that 77.7% of the granules were positive for STX17 with a mean±SEM of 3.9±0.2 gold particles/granule. Labeling was present on both granule outer membranes and matrices while EoSVs showed clear membrane-associated labeling. STX17 was also present in secretory granules in eosinophils stimulated with the cytokine tumor necrosis factor alpha (TNF-α) or the CC-chemokine ligand 11 CCL11 (eotaxin-1), stimuli that induce eosinophil degranulation. The number of secretory granules labeled for STX17 was significantly higher in CCL11 compared with the unstimulated group. The level of cell labeling did not change when unstimulated cells were compared with TNF-α-stimulated eosinophils. The present study clearly shows by immunanonogold EM that STX17 is localized in eosinophil secretory granules and transport vesicles and might be involved in the transport of granule-derived cargos. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Review of SKB's Quality Assurance Programme

    International Nuclear Information System (INIS)

    Baldwin, Tamara D.; Hicks, Timothy W.

    2009-06-01

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried of with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. SSM has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This project includes reviews of the quality assurance (QA) procedures and instructions that have been prepared for the SR-Site assessment as well as reviews of QA implementation at the canister and buffer/backfill laboratories in Oskarshamn, Sweden. The purpose of this project is to assess SKB's quality assurance with the view of providing a good basis for subsequent quality reviews in the context of future licensing. This has been achieved by examination of a number of SKB experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. Overall, the reviewed set of QA documents and instructions do provide reasonably comprehensive coverage of quality-affecting issues relating to the SR-Site safety assessment and, if implemented correctly, will generate confidence in the reliability of the safety assessment results. The results show that the efforts involving quality assurance are increasing within the SKB programme and in general appear to be satisfactory for ongoing experiments and measurements. However, progress in development of the QA documents and instructions has been relatively recent and it may be difficult for these to be fully implemented in the short period remaining before the planned licence

  9. Experience with the european quality assurance guidelines for digital mammography systems in a national screening programme

    International Nuclear Information System (INIS)

    McCullagh, J.; Keavey, E.; Egan, G.; Phelan, N.

    2013-01-01

    The transition to a fully digital breast screening programme, utilising three different full-field digital mammography (FFDM) systems has presented many challenges to the implementation of the European guidelines for physico-technical quality assurance (QA) testing. An analysis of the QA results collected from the FFDM systems in the screening programme over a 2-y period indicates that the three different systems have similar QA performances. Generally, the same tests were failed by all systems and failure rates were low. The findings provide some assurance that the QA guidelines are being correctly implemented. They also suggest that there is more scope for the development of the relevance of the guidelines with respect to modern FFDM systems. This study has also shown that a summary review of the QA data can be achieved by simple organisation of the QA data storage and by automation of data query and retrieval using commonly available software. (authors)

  10. Quality assurance tool for organ at risk delineation in radiation therapy using a parametric statistical approach.

    Science.gov (United States)

    Hui, Cheukkai B; Nourzadeh, Hamidreza; Watkins, William T; Trifiletti, Daniel M; Alonso, Clayton E; Dutta, Sunil W; Siebers, Jeffrey V

    2018-02-26

    To develop a quality assurance (QA) tool that identifies inaccurate organ at risk (OAR) delineations. The QA tool computed volumetric features from prior OAR delineation data from 73 thoracic patients to construct a reference database. All volumetric features of the OAR delineation are computed in three-dimensional space. Volumetric features of a new OAR are compared with respect to those in the reference database to discern delineation outliers. A multicriteria outlier detection system warns users of specific delineation outliers based on combinations of deviant features. Fifteen independent experimental sets including automatic, propagated, and clinically approved manual delineation sets were used for verification. The verification OARs included manipulations to mimic common errors. Three experts reviewed the experimental sets to identify and classify errors, first without; and then 1 week after with the QA tool. In the cohort of manual delineations with manual manipulations, the QA tool detected 94% of the mimicked errors. Overall, it detected 37% of the minor and 85% of the major errors. The QA tool improved reviewer error detection sensitivity from 61% to 68% for minor errors (P = 0.17), and from 78% to 87% for major errors (P = 0.02). The QA tool assists users to detect potential delineation errors. QA tool integration into clinical procedures may reduce the frequency of inaccurate OAR delineation, and potentially improve safety and quality of radiation treatment planning. © 2018 American Association of Physicists in Medicine.

  11. EORTC Radiation Oncology Group quality assurance platform: Establishment of a digital central review facility

    International Nuclear Information System (INIS)

    Fairchild, Alysa; Aird, Edwin; Fenton, Paul A.; Gregoire, Vincent; Gulyban, Akos; Lacombe, Denis; Matzinger, Oscar; Poortmans, Philip; Ruyskart, Pascal; Weber, Damien C.; Hurkmans, Coen W.

    2012-01-01

    Objective: Quality assurance (QA) in clinical trials is essential to ensure treatment is safely and effectively delivered. As QA requirements have increased in complexity in parallel with evolution of radiation therapy (RT) delivery, a need to facilitate digital data exchange emerged. Our objective is to present the platform developed for the integration and standardization of QART activities across all EORTC trials involving RT. Methods: The following essential requirements were identified: secure and easy access without on-site software installation; integration within the existing EORTC clinical remote data capture system; and the ability to both customize the platform to specific studies and adapt to future needs. After retrospective testing within several clinical trials, the platform was introduced in phases to participating sites and QART study reviewers. Results: The resulting QA platform, integrating RT analysis software installed at EORTC Headquarters, permits timely, secure, and fully digital central DICOM-RT based data review. Participating sites submit data through a standard secure upload webpage. Supplemental information is submitted in parallel through web-based forms. An internal quality check by the QART office verifies data consistency, formatting, and anonymization. QART reviewers have remote access through a terminal server. Reviewers evaluate submissions for protocol compliance through an online evaluation matrix. Comments are collected by the coordinating centre and institutions are informed of the results. Conclusions: This web-based central review platform facilitates rapid, extensive, and prospective QART review. This reduces the risk that trial outcomes are compromised through inadequate radiotherapy and facilitates correlation of results with clinical outcomes.

  12. Conformational differences between the methoxy groups of QA and QB site ubisemiquinones in bacterial reaction centers: a key role for methoxy group orientation in modulating ubiquinone redox potential.

    Science.gov (United States)

    Taguchi, Alexander T; O'Malley, Patrick J; Wraight, Colin A; Dikanov, Sergei A

    2013-07-09

    Ubiquinone is an almost universal, membrane-associated redox mediator. Its ability to accept either one or two electrons allows it to function in critical roles in biological electron transport. The redox properties of ubiquinone in vivo are determined by its environment in the binding sites of proteins and by the dihedral angle of each methoxy group relative to the ring plane. This is an attribute unique to ubiquinone among natural quinones and could account for its widespread function with many different redox complexes. In this work, we use the photosynthetic reaction center as a model system for understanding the role of methoxy conformations in determining the redox potential of the ubiquinone/semiquinone couple. Despite the abundance of X-ray crystal structures for the reaction center, quinone site resolution has thus far been too low to provide a reliable measure of the methoxy dihedral angles of the primary and secondary quinones, QA and QB. We performed 2D ESEEM (HYSCORE) on isolated reaction centers with ubiquinones (13)C-labeled at the headgroup methyl and methoxy substituents, and have measured the (13)C isotropic and anisotropic components of the hyperfine tensors. Hyperfine couplings were compared to those derived by DFT calculations as a function of methoxy torsional angle allowing estimation of the methoxy dihedral angles for the semiquinones in the QA and QB sites. Based on this analysis, the orientation of the 2-methoxy groups are distinct in the two sites, with QB more out of plane by 20-25°. This corresponds to an ≈50 meV larger electron affinity for the QB quinone, indicating a substantial contribution to the experimental difference in redox potentials (60-75 mV) of the two quinones. The methods developed here can be readily extended to ubiquinone-binding sites in other protein complexes.

  13. Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)

    Science.gov (United States)

    Purwaningsih, S.; Lubis, L. E.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    This research was aimed to check the patterns of dose profile on adult and pediatric head scan. We compared measurement result on dose profile along the z- axis rotation at peripheries and center phantom with a variety of pitch, i.e. 0.75, 1, 1.5 for adult and pediatric head protocol, keeping the rest of the scan parameters constant. Measurements were performed on homogeneous, cylindrical PMMA phantom with diameters of 16 and 10 cm using XR-QA2 Gafchromic film and TLD as dosimeters. The measurement result indicated a decrease in the dose about 50% and 47% for adult and pediatric head scan with the increase of pitch. For 0.75 value of pitch adult head scan, dose range for each position were (2.4 - 5.0) cGy, (3.1 - 5.3) cGy, (2.2 - 4.5) cGy, (2.8 - 5.3) cGy, and (3.3 - 5.6) cGy for position of center, 3, 6, 9 and 12 o'clock peripheral phantom position respectively. Dose profile for adult and pediatric head scan protocols has pattern curve with the maximum dose in the middle and tendency of symmetry near the edges, with different the plateau length along z- axis direction in accordance to the measurement position in the phantom.

  14. Peer Review Improves the Quality of MCQ Examinations

    Science.gov (United States)

    Malau-Aduli, Bunmi S.; Zimitat, Craig

    2012-01-01

    The aim of this study was to assess the effect of the introduction of peer review processes on the quality of multiple-choice examinations in the first three years of an Australian medical course. The impact of the peer review process and overall quality assurance (QA) processes were evaluated by comparing the examination data generated in earlier…

  15. A practical implementation of physics quality assurance for photon adaptive radiotherapy.

    Science.gov (United States)

    Cai, Bin; Green, Olga L; Kashani, Rojano; Rodriguez, Vivian L; Mutic, Sasa; Yang, Deshan

    2018-03-14

    The fast evolution of technology in radiotherapy (RT) enabled the realization of adaptive radiotherapy (ART). However, the new characteristics of ART pose unique challenges for efficiencies and effectiveness of quality assurance (QA) strategies. In this paper, we discuss the necessary QAs for ART and introduce a practical implementation. A previously published work on failure modes and effects analysis (FMEA) of ART is introduced first to explain the risks associated with ART sub-processes. After a brief discussion of QA challenges, we review the existing QA strategies and tools that might be suitable for each ART step. By introducing the MR-guided online ART QA processes developed at our institute, we demonstrate a practical implementation. The limitations and future works to develop more robust and efficient QA strategies are discussed at the end. Copyright © 2018. Published by Elsevier GmbH.

  16. Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density

    International Nuclear Information System (INIS)

    Gotanda, R.; Takeda, Y.; Gotanda, T.; Oishi Hospital, Hiroshima; Tabuchi, A.; Kawasaki Hospital, Okayama; Yamamoto, K.; Osaka Cancer Prevention and Detection Centre, Osaka; Kuwano, T.; Osaka Medical Center for Cancer and Cardovascular Diseases, Osaka; Yatake, H.; Kaizuka City Hospital, Osaka; Katsuda, T.

    2009-01-01

    The effective energy of diagnostic x-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the applicability of GAFCHROMIC XR type R (GAF-R) film for HVL measurement as an alternative to monitoring with an ionization chamber, a single-strip method for measuring the HVL has been evaluated. Calibration curves of absorbed dose versus film density were generated using this single-strip method with GAF-R film, and the coefficient of determination (r2) of the straight-line approximation was evaluated. The HVLs (effective energies) estimated using the GAF-R film and an ionization chamber were compared. The coefficient of determination (r2) of the straight-line approximation obtained with the GAF-R film was more than 0.99. The effective energies (HVLs) evaluated using the GAF-R film and the ionization chamber were 43.25 keV (5.10 m m) and 39.86 keV (4.45 mm), respectively. The difference in the effective energies determined by the two methods was thus 8.5%. These results suggest that GAF-R might be used to evaluate the effective energy from the film-density growth without the need for ionization-chamber measurements.

  17. Practical utility of on-line clearance and blood temperature monitors as noninvasive techniques to measure hemodialysis blood access flow.

    Science.gov (United States)

    Fontseré, Néstor; Blasco, Miquel; Maduell, Francisco; Vera, Manel; Arias-Guillen, Marta; Herranz, Sandra; Blanco, Teresa; Barrufet, Marta; Burrel, Marta; Montaña, Javier; Real, Maria Isabel; Mestres, Gaspar; Riambau, Vicenç; Campistol, Josep M

    2011-01-01

    Access blood flow (Qa) measurements are recommended by the current guidelines as one of the most important components in vascular access maintenance programs. This study evaluates the efficiency of Qa measurement with on-line conductivity (OLC-Qa) and blood temperature monitoring (BTM-Qa) in comparison with the gold standard saline dilution method (SDM-Qa). 50 long-term hemodialysis patients (42 arteriovenous fistulas/8 arteriovenous grafts) were studied. Bland-Altman and Lin's coefficient (ρ(c)) were used to study accuracy and precision. Mean values were 1,021.7 ± 502.4 ml/min SDM-Qa, 832.8 ± 574.3 ml/min OLC-Qa (p = 0.007) and 1,094.9 ± 491.9 ml/min with BTM-Qa (p = NS). Biases and ρ(c) obtained were -188.8 ml/min (ρ(c) 0.58) OLC-Qa and 73.2 ml/min (ρ(c) 0.89) BTM-Qa. The limits of agreement (bias ± 1.96 SD) obtained were from -1,119 to 741.3 ml/min (OLC-Qa) and -350.6 to 497.2 ml/min (BTM-Qa). BTM-Qa and OLC-Qa are valid noninvasive and practical methods to estimate Qa, although BTM-Qa was more accurate and had better concordance than OLC-Qa compared with SDM-Qa. Copyright © 2010 S. Karger AG, Basel.

  18. MO-F-CAMPUS-T-02: Dosimetric Accuracy of the CrystalBallâ„¢: New Reusable Radiochromic Polymer Gel Dosimeter for Patient QA in Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Avery, S; Kraus, J; Lin, L; Kassaee, A [University of Pennsylvania, Philadelphia, PA (United States); Maryanski, M [MGS Research, Inc., Madison, CT (United States)

    2015-06-15

    Purpose: To evaluate the accuracy of monoexponential normalization in a new class of commercial, reusable, human-soft-tissue-equivalent, radiochromic polymer gel dosimeters for patient-specific QA in proton therapy. Methods: Eight formulations of the dosimeter (sealed in glass spheres of 166 mm OD), were exposed to a 150 MeV proton beam (5 cm x 5 cm square field, range 15 cm, modulation10 cm), with max dose ranging from 2.5 Gy to 20 Gy, depending on formulation. Exposed dosimeters were promptly placed in the commercial OCTOPUS™ laser CT scanner which was programmed to scan the central slice every 5 minutes for 20 hours (15 seconds per slice scan). This procedure was repeated several times. Reconstructed data were analyzed using the log-lin scale to determine the time range over which a monoexponential relaxation model could be applied. Next, a simple test plan was devised and delivered to each dosimeter. The OCTOPUS™ was programmed to rescan the central slice at the end of each volume scan, for signal relaxation reference. Monoexponential normalization was applied to sinograms before FBP reconstruction. Dose calibration was based on a volume-lookup table built within the central spherical volume of 12 cm diameter. 3D gamma and sigma passing rates were measured at 3%/3mm criteria down to 50% isodose. Results: Approximately monoexponential signal relaxation time ranges from 25 minutes to 3.5 hours, depending on formulation, followed by a slower-relaxation component. Noise in reconstructed OD/cm images is less than 0.5%. Dose calibration accuracy is better than 99%. Measured proton PDDs demonstrate absence of Bragg-peak quenching. Estimated number of useful cycles is at least 20, with a theoretical limit above 100. 3D gamma and sigma passing rates exceed 95%. Conclusion: Monoexponential normalization was found to yield adequate dosimetric accuracy in the new class of commercial radiochromic polymer gel dosimeters for patient QA in proton therapy.

  19. MO-F-CAMPUS-T-02: Dosimetric Accuracy of the CrystalBallâ„¢: New Reusable Radiochromic Polymer Gel Dosimeter for Patient QA in Proton Therapy

    International Nuclear Information System (INIS)

    Avery, S; Kraus, J; Lin, L; Kassaee, A; Maryanski, M

    2015-01-01

    Purpose: To evaluate the accuracy of monoexponential normalization in a new class of commercial, reusable, human-soft-tissue-equivalent, radiochromic polymer gel dosimeters for patient-specific QA in proton therapy. Methods: Eight formulations of the dosimeter (sealed in glass spheres of 166 mm OD), were exposed to a 150 MeV proton beam (5 cm x 5 cm square field, range 15 cm, modulation10 cm), with max dose ranging from 2.5 Gy to 20 Gy, depending on formulation. Exposed dosimeters were promptly placed in the commercial OCTOPUS™ laser CT scanner which was programmed to scan the central slice every 5 minutes for 20 hours (15 seconds per slice scan). This procedure was repeated several times. Reconstructed data were analyzed using the log-lin scale to determine the time range over which a monoexponential relaxation model could be applied. Next, a simple test plan was devised and delivered to each dosimeter. The OCTOPUS™ was programmed to rescan the central slice at the end of each volume scan, for signal relaxation reference. Monoexponential normalization was applied to sinograms before FBP reconstruction. Dose calibration was based on a volume-lookup table built within the central spherical volume of 12 cm diameter. 3D gamma and sigma passing rates were measured at 3%/3mm criteria down to 50% isodose. Results: Approximately monoexponential signal relaxation time ranges from 25 minutes to 3.5 hours, depending on formulation, followed by a slower-relaxation component. Noise in reconstructed OD/cm images is less than 0.5%. Dose calibration accuracy is better than 99%. Measured proton PDDs demonstrate absence of Bragg-peak quenching. Estimated number of useful cycles is at least 20, with a theoretical limit above 100. 3D gamma and sigma passing rates exceed 95%. Conclusion: Monoexponential normalization was found to yield adequate dosimetric accuracy in the new class of commercial radiochromic polymer gel dosimeters for patient QA in proton therapy

  20. Review of SKB's Quality Assurance Programme

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, Tamara D.; Hicks, Timothy W. (Galson Sciences LTD, Oakham, Rutland (United Kingdom))

    2009-06-15

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried of with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. SSM has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This project includes reviews of the quality assurance (QA) procedures and instructions that have been prepared for the SR-Site assessment as well as reviews of QA implementation at the canister and buffer/backfill laboratories in Oskarshamn, Sweden. The purpose of this project is to assess SKB's quality assurance with the view of providing a good basis for subsequent quality reviews in the context of future licensing. This has been achieved by examination of a number of SKB experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. Overall, the reviewed set of QA documents and instructions do provide reasonably comprehensive coverage of quality-affecting issues relating to the SR-Site safety assessment and, if implemented correctly, will generate confidence in the reliability of the safety assessment results. The results show that the efforts involving quality assurance are increasing within the SKB programme and in general appear to be satisfactory for ongoing experiments and measurements. However, progress in development of the QA documents and instructions has been relatively recent and it may be difficult for these to be fully implemented in the short period remaining before the planned

  1. Independent oversight review of the Department of Energy Quality Assurance Program for suspect/counterfeit parts. Revision 1

    International Nuclear Information System (INIS)

    1996-05-01

    To address the potential threat that suspect/counterfeit parts could pose to DOE workers and the public, the Office of the Deputy Assistant Secretary for Oversight initiated a number of activities beginning in mid-1995. Oversight placed increased emphasis on the field's quality assurance-suspect/counterfeit parts programs during safety management evaluations, in keeping with the Office of Environment, Safety and Health (EH) oversight responsibilities, which include oversight of the Department's quality assurance (QA) programs. In addition, Oversight reviewed relevant policy documents and occurrence reports to determine the nature and magnitude of the problem within the Department. The results of that review, contained in an Office of Oversight report, Independent Oversight Analysis of Suspect/Counterfeit Parts Within the Department of Energy (November 1995), indicate a lack of consistency and comprehensiveness in the Department's QA-suspect/counterfeit parts program. A detailed analysis of the causes and impacts of the problem was recommended. In response, this review was initiated to determine the effectiveness of the Department's QA program for suspect/counterfeit parts. This study goes beyond merely assessing and reporting the status of the program, however. It is the authors intention to highlight the complex issues associated with suspect/counterfeit parts in the Department today and to present approaches that DOE managers might consider to address these issues

  2. Independent oversight review of the Department of Energy Quality Assurance Program for suspect/counterfeit parts. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    To address the potential threat that suspect/counterfeit parts could pose to DOE workers and the public, the Office of the Deputy Assistant Secretary for Oversight initiated a number of activities beginning in mid-1995. Oversight placed increased emphasis on the field`s quality assurance-suspect/counterfeit parts programs during safety management evaluations, in keeping with the Office of Environment, Safety and Health (EH) oversight responsibilities, which include oversight of the Department`s quality assurance (QA) programs. In addition, Oversight reviewed relevant policy documents and occurrence reports to determine the nature and magnitude of the problem within the Department. The results of that review, contained in an Office of Oversight report, Independent Oversight Analysis of Suspect/Counterfeit Parts Within the Department of Energy (November 1995), indicate a lack of consistency and comprehensiveness in the Department`s QA-suspect/counterfeit parts program. A detailed analysis of the causes and impacts of the problem was recommended. In response, this review was initiated to determine the effectiveness of the Department`s QA program for suspect/counterfeit parts. This study goes beyond merely assessing and reporting the status of the program, however. It is the authors intention to highlight the complex issues associated with suspect/counterfeit parts in the Department today and to present approaches that DOE managers might consider to address these issues.

  3. Workshop on measurement quality assurance for ionizing radiation: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Heath, J.A.; Swinth, K.L. [comps.

    1993-12-31

    This workshop was held to review the status of secondary level calibration accreditation programs, review related measurement accreditation programs, document lessons learned, and to present changes in programs due to new national priorities involving radioactivity measurements. Contents include: fundamentals of measurement quality assurance (MQA), standards for MQA programs; perspectives and policies; complete MQA programs; future MQA programs; QA/QC programs--radioactivity; QA/QC programs--dosimetry; laboratory procedures for QA/QC; in-house control of reference dosimetry laboratories; in-house controls of radioactivity laboratories; and poster session. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  4. Workshop on measurement quality assurance for ionizing radiation: Proceedings

    International Nuclear Information System (INIS)

    Heath, J.A.; Swinth, K.L.

    1993-01-01

    This workshop was held to review the status of secondary level calibration accreditation programs, review related measurement accreditation programs, document lessons learned, and to present changes in programs due to new national priorities involving radioactivity measurements. Contents include: fundamentals of measurement quality assurance (MQA), standards for MQA programs; perspectives and policies; complete MQA programs; future MQA programs; QA/QC programs--radioactivity; QA/QC programs--dosimetry; laboratory procedures for QA/QC; in-house control of reference dosimetry laboratories; in-house controls of radioactivity laboratories; and poster session. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  5. Key Performance Indicators in Radiology: You Can't Manage What You Can't Measure.

    Science.gov (United States)

    Harvey, H Benjamin; Hassanzadeh, Elmira; Aran, Shima; Rosenthal, Daniel I; Thrall, James H; Abujudeh, Hani H

    2016-01-01

    Quality assurance (QA) is a fundamental component of every successful radiology operation. A radiology QA program must be able to efficiently and effectively monitor and respond to quality problems. However, as radiology QA has expanded into the depths of radiology operations, the task of defining and measuring quality has become more difficult. Key performance indicators (KPIs) are highly valuable data points and measurement tools that can be used to monitor and evaluate the quality of services provided by a radiology operation. As such, KPIs empower a radiology QA program to bridge normative understandings of health care quality with on-the-ground quality management. This review introduces the importance of KPIs in health care QA, a framework for structuring KPIs, a method to identify and tailor KPIs, and strategies to analyze and communicate KPI data that would drive process improvement. Adopting a KPI-driven QA program is both good for patient care and allows a radiology operation to demonstrate measurable value to other health care stakeholders. Copyright © 2015 Mosby, Inc. All rights reserved.

  6. Experience in the application of NUSS and Canadian quality assurance standards for overseas CANDU projects

    International Nuclear Information System (INIS)

    Simmons, R.B.V.; Thomas, R.A.

    1984-10-01

    The Canadian QA standards - the CSA Z299 series for manufacture, which first appeared in 1975, and the CSA N286 series for all other phases of plant life which appeared in 1979, have been based on experience with the CANDU reactor program. The CSA Technical Committee responsible for issue and for updating the two series have a direct liaison with the IAEA Technical Review Committee for Quality Assurance. Ontario Hydro, which has a substantial commitment to nuclear power using CANDU reactors, has played a large part in the Canadian QA standards program. Atomic Energy of Canada Limited has also taken a major part in the development of CSA QA standards. As a main contractor the Company has supplied CANDU plants in Canada and to Argentina, South Korea and Romania. Because of the compatibility of the Canadian QA standards used, the Embalse plant in Argentina and the Wolsung 1 plant in Korea, are essentially in compliance with NUSS QA standards. The plant under construction at Cernavoda in Romania similarly follows Canadian QA standards

  7. BUILDING "BRIDGES" WITH QUALITY ASSURANCE

    Science.gov (United States)

    The papr describes how, rather than building "bridges" across centuries, quality assurance (QA) personnel have the opportunity to build bridges across technical disciplines, between public and private organizations, and between different QA groups. As reviewers and auditors of a...

  8. A framework for a quality assurance programme for PSA

    International Nuclear Information System (INIS)

    1999-08-01

    Reviews organized by the IAEA of probabilistic safety assessments (PSAs) of nuclear facilities have, in the past years, shown significant progress in the technical methods and data used for these studies. The IAEA has made a considerable effort to support the development of technical capabilities for PSA in Member States and in writing technical procedures for carrying out PSAs. However, the reviews have also shown significant deficiencies in quality assurance (QA) for PSAs, ranging from no QA at all to inappropriate, inefficient or unbalanced QA. As a PSA represents a very complex model which describes the risk associated with a nuclear facility, an appropriate and efficient QA programme is crucial to obtain a quality PSA. Historically, in the first integral PSAs, many of the PSA elements were handled by independent groups. These elements were finally integrated and put together in the overall model. Many of the interfaces between the elements or tasks were handled as appropriate by exchanging information in oral or written form. Since WASH-1400, the first integral PSA, the process of constructing the PSA model has been further developed. PSA elements previously considered separately can now be handled together with the capable software developed in recent years. Software has made interface control and data transfer easier to perform, but also permits the development of more detailed and complex models. Previously, QA for PSA projects was organized in an ad hoc manner and was sometimes very limited. In recent years, increasingly comprehensive QA programmes have been developed and implemented for PSA projects. Today, a comprehensive, effective and performance-oriented QA is considered to be essential for a reliable and credible PSA. This report describes the framework for developing an adequate QA programme for PSA studies. The framework is based on and is in accordance with the related QA guidelines of the IAEA for safety in nuclear power plants and other nuclear

  9. Status of quality assurance system for R and D in BNL

    International Nuclear Information System (INIS)

    Park, Chan Gook; Lim, Nam Jin; Lee, Young Gun; Kim, Kwan Hyun; Nam, Ji Hee

    2003-03-01

    This study aims to frame a basic policy for adoption of R and D QA and to guide the improvement of existing nuclear facilities-centered QA systems for regular enforcement of R and D QA in the future. We investigated the state-of-the-art of R and D QA systems in U.S.A where R and D QA is most comprehensively applied in the world. We also investigated the implementation process of QA activities to understand the state of the operation of QA system. The policy for improvement of existing QA systems for regular enforcement of R and D QA in Korea were established through the comparative study of QA system between U.S.A and Korea

  10. Les théories des mouvements sociaux et la dialectique des niveaux : un cadre d’analyse pour l’étude des évolutions d’Al-Qaïda au Maghreb islamique

    OpenAIRE

    Adib Bencherif

    2013-01-01

    Les théories des mouvements sociaux sont de plus en plus utilisées pour étudier les groupes terroristes. Elles comportent différents niveaux d’analyse: les niveaux macro-analytique, méso-analytique et micro-analytique. Le présent article tente d’adapter ce corpus théorique à l’étude du groupe jihadiste Al-Qaïda au Maghreb islamique (AQMI). En effet, au cours des dernières années, AQMI ne s’est pas développé au Maghreb alors que ses activités ont augmenté exponentiellement dans la région sahél...

  11. An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantom.

    Science.gov (United States)

    Sun, Jidi; Barnes, Michael; Dowling, Jason; Menk, Fred; Stanwell, Peter; Greer, Peter B

    2015-03-01

    Routine quality assurance (QA) is necessary and essential to ensure MR scanner performance. This includes geometric distortion, slice positioning and thickness accuracy, high contrast spatial resolution, intensity uniformity, ghosting artefact and low contrast object detectability. However, this manual process can be very time consuming. This paper describes the development and validation of an open source tool to automate the MR QA process, which aims to increase physicist efficiency, and improve the consistency of QA results by reducing human error. The OSAQA software was developed in Matlab and the source code is available for download from http://jidisun.wix.com/osaqa-project/. During program execution QA results are logged for immediate review and are also exported to a spreadsheet for long-term machine performance reporting. For the automatic contrast QA test, a user specific contrast evaluation was designed to improve accuracy for individuals on different display monitors. American College of Radiology QA images were acquired over a period of 2 months to compare manual QA and the results from the proposed OSAQA software. OSAQA was found to significantly reduce the QA time from approximately 45 to 2 min. Both the manual and OSAQA results were found to agree with regard to the recommended criteria and the differences were insignificant compared to the criteria. The intensity homogeneity filter is necessary to obtain an image with acceptable quality and at the same time keeps the high contrast spatial resolution within the recommended criterion. The OSAQA tool has been validated on scanners with different field strengths and manufacturers. A number of suggestions have been made to improve both the phantom design and QA protocol in the future.

  12. Quality assurance program preparation - review of requirements and plant systems - selection of program levels

    International Nuclear Information System (INIS)

    Asmuss, G.

    1980-01-01

    The establishment and implementation for a practicable quality assurance program for a nuclear power plant demands a detailed background in the field of engineering, manufacturing, organization and quality assurance. It will be demonstrated with examples to define and control the achievement of quality related activities during the phases of design, procurement, manufactoring, commissioning and operation. In general the quality assurance program applies to all items, processes and services important to safety of nuclear power plant. The classification for safety related and non-safety related items and services demonstrate the levels of quality assurance requirements. The lecture gives an introduction of QA Program preparation under the following topics: -Basic criteria and international requirements - Interaction of QA activities - Modular and product oriented QA programs - Structuring of organization for the QA program - Identification of the main quality assurance functions and required actions - Quality Assurance Program documentation - Documentation of planning of activities - Control of program documents - Definitions. (orig./RW)

  13. Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements

    International Nuclear Information System (INIS)

    Visser, R.; Wauben, D. J. L.; Godart, J.; Langendijk, J. A.; Veld, A. A. van't; Korevaar, E. W.; Groot, M. de

    2013-01-01

    Purpose: Advanced radiotherapy treatments require appropriate quality assurance (QA) to verify 3D dose distributions. Moreover, increase in patient numbers demand efficient QA-methods. In this study, a time efficient method that combines model-based QA and measurement-based QA was developed; i.e., the hybrid-QA. The purpose of this study was to determine the reliability of the model-based QA and to evaluate time efficiency of the hybrid-QA method. Methods: Accuracy of the model-based QA was determined by comparison of COMPASS calculated dose with Monte Carlo calculations for heterogeneous media. In total, 330 intensity modulated radiation therapy (IMRT) treatment plans were evaluated based on the mean gamma index (GI) with criteria of 3%/3mm and classification of PASS (GI ≤ 0.4), EVAL (0.4 0.6), and FAIL (GI ≥ 0.6). Agreement between model-based QA and measurement-based QA was determined for 48 treatment plans, and linac stability was verified for 15 months. Finally, time efficiency improvement of the hybrid-QA was quantified for four representative treatment plans. Results: COMPASS calculated dose was in agreement with Monte Carlo dose, with a maximum error of 3.2% in heterogeneous media with high density (2.4 g/cm 3 ). Hybrid-QA results for IMRT treatment plans showed an excellent PASS rate of 98% for all cases. Model-based QA was in agreement with measurement-based QA, as shown by a minimal difference in GI of 0.03 ± 0.08. Linac stability was high with an average GI of 0.28 ± 0.04. The hybrid-QA method resulted in a time efficiency improvement of 15 min per treatment plan QA compared to measurement-based QA. Conclusions: The hybrid-QA method is adequate for efficient and accurate 3D dose verification. It combines time efficiency of model-based QA with reliability of measurement-based QA and is suitable for implementation within any radiotherapy department.

  14. Management services, quality assurance, and safety

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Broad technical and administrative support for the programmatic research and development activities of the Fusion Energy Division is provided by the Management Services Section and by the division's quality assurance (QA) and safety programs. Support is provided through effective communication with division programmatic staff and through the coordination of resources from disciplines outside the division. The QA activity in the division emphasizes the development and documentation of a QA program that conforms to national standards, the review and approval of engineering documents, supplier surveillance, identification and documentation of nonconforming items, audits, and QA assessments/plans. The division's safety activities include a formal safety program, emergency planning activities, and environmental protection services. Efforts devoted to the removal of hazardous wastes from division facilities were expanded during 1986

  15. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  16. Establishing software quality assurance

    International Nuclear Information System (INIS)

    Malsbury, J.

    1983-01-01

    This paper is concerned with four questions about establishing software QA: What is software QA. Why have software QA. What is the role of software QA. What is necessary to ensure the success of software QA

  17. Quality assurance records system for research and development activities in support of geologic repository programs

    International Nuclear Information System (INIS)

    Smith, J.W.; Ryder, D.E.

    1987-01-01

    The Pacific Northwest Laboratory (PNL), which is operated by Battelle Memorial Institute for the Department of Energy, is conducting site-specific research for all three candidate sites for the first geologic high-level waste repository, as well as generic research for the second repository. In conjunction with this effort, PNL has developed a quality assurance (QA) program that is applicable to all organizations that are performing research and development (R and D) activities in support of the repository programs. This QA program meets the basic and supplemental requirements of ANSI/ASME NQA-1-1983 and the Nuclear Regulatory Commission (NRC) Review Plan for QA Programs for Site Characterization of High Level Nuclear Waste Repositories. A key part of this program is the handling of QA records that may ultimately support the licensing process for the repository. This paper describes a QA records system that is flexible enough to accommodate several types of research, such as paper studies, test method development, site characterization studies, software development, and hardware design. In addition, the QA records system is acceptable to a variety of sponsors who have licensing concerns. The QA procedures and their relation to the requirements are described. Most important is the discussion on the approaches used to assure that the records are organized such that the user can readily recreate or defend data, conclusions, and recommendations resulting from the research

  18. Impact of Quality Assurance Rounds in a Canadian Radiation Therapy Department

    International Nuclear Information System (INIS)

    Lefresne, Shilo; Olivotto, Ivo A.; Joe, Howard; Blood, Paul A.; Olson, Robert A.

    2013-01-01

    Purpose: Quality assurance (QA) programs aim to identify inconsistencies that may compromise patient care. Radiation treatment planning is a well-documented source of variation in radiation oncology, leading many organizations to recommend the implementation of QA rounds in which radiation therapy plans are peer reviewed. This study evaluates the outcome of QA rounds that have been conducted by a radiation therapy department since 2004. Methods and Materials: Prospectively documented records of QA rounds, from 2004 to 2010, were obtained. During rounds, randomly selected radiation therapy plans were peer reviewed and assigned a grade of A (adequate), B (minor suggestions of change to a plan for a future patient), or C (significant change required before the next fraction). The proportion of plans that received each recommendation was calculated, and the relationship between recommendations for each plan, tumor site, and mean years of experience of the radiation oncologist (RO) were explored. Chart reviews were performed for each plan that received a C. Results: During the study period, 1247 plans were evaluated; 6% received a B and 1% received a C. The mean RO years of experience were lower for plans graded C versus those graded A (P=.02). The tumor sites with the highest proportion of plans graded B or C were gastrointestinal (14%), lung (13%), and lymphoma (8%). The most common reasons for plans to receive a grade of C were inadequate target volume coverage (36%), suboptimal dose or fractionation (27%), errors in patient setup (27%), and overtreatment of normal tissue (9%). Conclusions: This study demonstrated that QA rounds are feasible and an important element of a radiation therapy department's QA program. Through peer review, plans that deviate from a department's expected standard can be identified and corrected. Additional benefits include identifying patterns of practice that may contribute to inconsistencies in treatment planning and the continuing

  19. Involving mental health service users in quality assurance

    Science.gov (United States)

    Weinstein, Jenny

    2006-01-01

    Abstract Objective  This study compares the process and outcomes of two approaches to engaging mental health (MH) service users in the quality assurance (QA) process. Background  QA plays a significant role in health and care services, including those delivered in the voluntary sector. The importance of actively, rather than passively, involving service users in evaluation and service development has been increasingly recognized during the last decade. Design  This retrospective small‐scale study uses document analysis to compare two QA reviews of a MH Day Centre, one that took place in 1998 as a traditional inspection‐type event and one that took place in 2000 as a collaborative process with a user‐led QA agenda. Setting and participants  The project was undertaken with staff, volunteers and service users in a voluntary sector MH Day Centre. Intervention  The study compares the management, style, evaluation tools and service user responses for the two reviews; it considers staff perspectives and discusses the implications of a collaborative, user‐led QA process for service development. Results  The first traditional top–down inspection‐type QA event had less ownership from service users and staff and served the main purpose of demonstrating that services met organizational standards. The second review, undertaken collaboratively with a user‐led agenda focused on different priorities, evolving a new approach to seeking users’ views and achieving a higher response rate. Conclusions  Because both users and staff had participated in most aspects of the second review they were more willing to work together and action plan to improve the service. It is suggested that the process contributed to an evolving ethos of more effective quality improvement and user involvement within the organization. PMID:16677189

  20. Quality Assurance in Higher Education: A Review of Literature

    Science.gov (United States)

    Ryan, Tricia

    2015-01-01

    This paper examines the literature surrounding quality assurance in global higher education. It provides an overview of accreditation as a mechanism to ensure quality in higher education, examines models of QA, and explores the concept of quality (including definitions of quality and quality assurance). In addition, this paper provides a review of…

  1. MO-E-BRB-04: Real-Time Exit-Fluence Delivery Validation

    Energy Technology Data Exchange (ETDEWEB)

    Siebers, J. [University of Virginia Health System (United States)

    2015-06-15

    Recent high profile reports of technical failures and human errors causing severe radiation- induced injuries and deaths come in support of the sustained efforts to ensure patient safety in the delivery of radiation treatments. In addition, highly conformal radiation therapies and escalated fraction doses mandate increased and sustained accuracy of the entire radiotherapy process. Consequently, and as a Result of AAPM and ASTRO led efforts patient specific quality assurance for specialized radiation treatments such as IMRT, SRS/SBRT and Arc Therapy had become a three-tier process: Pre-treatment, during treatment, and post treatment patient specific QA. Traditional patient QA consists of pre-treatment data transfer integrity dosimetric verifications and during-treatment geometric verifications. However, as treatment adaptation becomes closer to deployment in the clinics, during treatment validation via exit detectors had become a realistic QA option, permitting plan assessment in near real time. Post-treatment, machine logs allow comparisons of a range of mechanical parameters. A combination of these techniques could be used in evaluating inter-fraction, and intra-fraction delivery over a long time period such as an year, to evaluate the significant errors per site, per treatment technique. This type of data mining over longer periods of time provides the potential to recognize suboptimal radiation treatments, while allowing to identify systematic, possibly significant errors. This would allow creation of a data base of realized errors, small and large in dosimetry that could be for process or equipment improvement. This educational symposium will describe and review patient QA techniques, results, and strategies for patient specific quality assurance. Learning Objectives: review the goals of pre-treatment QA for various specialized procedures review methods and means for pre-treatment QA, limitations and tolerances review the scenarios where Varian/Tomo Log files

  2. MO-E-BRB-04: Real-Time Exit-Fluence Delivery Validation

    International Nuclear Information System (INIS)

    Siebers, J.

    2015-01-01

    Recent high profile reports of technical failures and human errors causing severe radiation- induced injuries and deaths come in support of the sustained efforts to ensure patient safety in the delivery of radiation treatments. In addition, highly conformal radiation therapies and escalated fraction doses mandate increased and sustained accuracy of the entire radiotherapy process. Consequently, and as a Result of AAPM and ASTRO led efforts patient specific quality assurance for specialized radiation treatments such as IMRT, SRS/SBRT and Arc Therapy had become a three-tier process: Pre-treatment, during treatment, and post treatment patient specific QA. Traditional patient QA consists of pre-treatment data transfer integrity dosimetric verifications and during-treatment geometric verifications. However, as treatment adaptation becomes closer to deployment in the clinics, during treatment validation via exit detectors had become a realistic QA option, permitting plan assessment in near real time. Post-treatment, machine logs allow comparisons of a range of mechanical parameters. A combination of these techniques could be used in evaluating inter-fraction, and intra-fraction delivery over a long time period such as an year, to evaluate the significant errors per site, per treatment technique. This type of data mining over longer periods of time provides the potential to recognize suboptimal radiation treatments, while allowing to identify systematic, possibly significant errors. This would allow creation of a data base of realized errors, small and large in dosimetry that could be for process or equipment improvement. This educational symposium will describe and review patient QA techniques, results, and strategies for patient specific quality assurance. Learning Objectives: review the goals of pre-treatment QA for various specialized procedures review methods and means for pre-treatment QA, limitations and tolerances review the scenarios where Varian/Tomo Log files

  3. AmeriFlux Data Processing: Integrating automated and manual data management across software technologies and an international network to generate timely data products

    Science.gov (United States)

    Christianson, D. S.; Beekwilder, N.; Chan, S.; Cheah, Y. W.; Chu, H.; Dengel, S.; O'Brien, F.; Pastorello, G.; Sandesh, M.; Torn, M. S.; Agarwal, D.

    2017-12-01

    AmeriFlux is a network of scientists who independently collect eddy covariance and related environmental observations at over 250 locations across the Americas. As part of the AmeriFlux Management Project, the AmeriFlux Data Team manages standardization, collection, quality assurance / quality control (QA/QC), and distribution of data submitted by network members. To generate data products that are timely, QA/QC'd, and repeatable, and have traceable provenance, we developed a semi-automated data processing pipeline. The new pipeline consists of semi-automated format and data QA/QC checks. Results are communicated via on-line reports as well as an issue-tracking system. Data processing time has been reduced from 2-3 days to a few hours of manual review time, resulting in faster data availability from the time of data submission. The pipeline is scalable to the network level and has the following key features. (1) On-line results of the format QA/QC checks are available immediately for data provider review. This enables data providers to correct and resubmit data quickly. (2) The format QA/QC assessment includes an automated attempt to fix minor format errors. Data submissions that are formatted in the new AmeriFlux FP-In standard can be queued for the data QA/QC assessment, often with minimal delay. (3) Automated data QA/QC checks identify and communicate potentially erroneous data via online, graphical quick views that highlight observations with unexpected values, incorrect units, time drifts, invalid multivariate correlations, and/or radiation shadows. (4) Progress through the pipeline is integrated with an issue-tracking system that facilitates communications between data providers and the data processing team in an organized and searchable fashion. Through development of these and other features of the pipeline, we present solutions to challenges that include optimizing automated with manual processing, bridging legacy data management infrastructure with

  4. How users adopt healthcare information: An empirical study of an online Q&A community.

    Science.gov (United States)

    Jin, Jiahua; Yan, Xiangbin; Li, Yijun; Li, Yumei

    2016-02-01

    The emergence of social media technology has led to the creation of many online healthcare communities, where patients can easily share and look for healthcare-related information from peers who have experienced a similar problem. However, with increased user-generated content, there is a need to constantly analyse which content should be trusted as one sifts through enormous amounts of healthcare information. This study aims to explore patients' healthcare information seeking behavior in online communities. Based on dual-process theory and the knowledge adoption model, we proposed a healthcare information adoption model for online communities. This model highlights that information quality, emotional support, and source credibility are antecedent variables of adoption likelihood of healthcare information, and competition among repliers and involvement of recipients moderate the relationship between the antecedent variables and adoption likelihood. Empirical data were collected from the healthcare module of China's biggest Q&A community-Baidu Knows. Text mining techniques were adopted to calculate the information quality and emotional support contained in each reply text. A binary logistics regression model and hierarchical regression approach were employed to test the proposed conceptual model. Information quality, emotional support, and source credibility have significant and positive impact on healthcare information adoption likelihood, and among these factors, information quality has the biggest impact on a patient's adoption decision. In addition, competition among repliers and involvement of recipients were tested as moderating effects between these antecedent factors and the adoption likelihood. Results indicate competition among repliers positively moderates the relationship between source credibility and adoption likelihood, and recipients' involvement positively moderates the relationship between information quality, source credibility, and adoption

  5. Improvements of the ALICE high level trigger for LHC Run 2 to facilitate online reconstruction, QA, and calibration

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, David [Frankfurt Institute for Advanced Studies, Frankfurt (Germany); Collaboration: ALICE-Collaboration

    2016-07-01

    ALICE is one of the four major experiments at the Large Hadron Collider (LHC) at CERN. Its main goal is the study of matter under extreme pressure and temperature as produced in heavy ion collisions at LHC. The ALICE High Level Trigger (HLT) is an online compute farm of around 200 nodes that performs a real time event reconstruction of the data delivered by the ALICE detectors. The HLT employs a fast FPGA based cluster finder algorithm as well as a GPU based track reconstruction algorithm and it is designed to process the maximum data rate expected from the ALICE detectors in real time. We present new features of the HLT for LHC Run 2 that started in 2015. A new fast standalone track reconstruction algorithm for the Inner Tracking System (ITS) enables the HLT to compute and report to LHC the luminous region of the interactions in real time. We employ a new dynamically reconfigurable histogram component that allows the visualization of characteristics of the online reconstruction using the full set of events measured by the detectors. This improves our monitoring and QA capabilities. During Run 2, we plan to deploy online calibration, starting with the calibration of the TPC (Time Projection Chamber) detector's drift time. First proof of concept tests were successfully performed using data-replay on our development cluster and during the heavy ion period at the end of 2015.

  6. The Concepts of Quality, Quality Assurance and Quality Enhancement

    Science.gov (United States)

    Elassy, Noha

    2015-01-01

    Purpose: This paper aims to critically review and discuss different definitions of the concepts of quality, quality assurance (QA) and quality enhancement (QE) in higher education (HE) with presenting critical perspectives of the literature. Design/methodology/approach: The paper looks at literature concerns with the meaning of quality, QA and QE,…

  7. WE-AB-201-04: The Recommendations of MPPG #5 and Practical Implementation Strategies

    International Nuclear Information System (INIS)

    Smilowitz, J.

    2015-01-01

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  8. WE-AB-201-04: The Recommendations of MPPG #5 and Practical Implementation Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Smilowitz, J. [University of Wisconsin (United States)

    2015-06-15

    Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar

  9. New techniques in quality assurance

    International Nuclear Information System (INIS)

    Fornicola, J.C.

    1987-01-01

    GPU Nuclear Corp. has a multifaceted quality assurance (QA) program. This program includes a comprehensive QA organization to help ensure its implementation. The QA organization employs various techniques in assuring quality at GPU Nuclear. These techniques not only include the typical QA/quality-control verification activities, i.e., QA engineering, quality control, and audits, but also include some new innovative techniques. Several new techniques have been developed for verifying activities. These techniques include monitoring and functional audits of safety systems. Several new techniques for assessing performance and adequacy and effectiveness of plant and QA programs, such as plant assessments and QA systems engineering evaluations, have also been developed. This paper provides an overview of these and other new techniques being employed by GPU Nuclear's QA organization

  10. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

  11. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    International Nuclear Information System (INIS)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X

    2016-01-01

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

  12. Exploring the Learning Mechanism of Web-Based Question-Answering Systems and Their Design

    Science.gov (United States)

    Zhang, Yin

    2010-01-01

    In recent years, a number of models concerning question-answering (QA) systems have been put forward. But many of them stress technology and neglect the research of QA itself. In this paper, we analyse the essence of QA and discuss the relationship between technology and QA. On that basis, we propose that when designing web-based QA systems, more…

  13. Set up and programming of an ALICE Time-Of-Flight trigger facility and software implementation for its Quality Assurance (QA) during LHC Run 2

    CERN Document Server

    Toschi, Francesco

    2016-01-01

    The Cosmic and Topology Trigger Module (CTTM) is the main component of a trigger based on the ALICE TOF detector. Taking advantage of the TOF fast response, this VME board implements the trigger logic and delivers several L0 trigger outputs, used since Run 1, to provide cosmic triggers and rare triggers in pp, p+Pb and Pb+Pb data taking. Due to TOF DCS architectural change of the PCs controlling the CTTM (from 32 bits to 64 bits) it is mandatory to upgrade the software related to the CTTM including the code programming the FPGA firmware. A dedicated CTTM board will be installed in a CERN lab (Meyrin site), with the aim of recreating the electronics chain of the TOF trigger, to get a comfortable porting of the code to the 64 bit environment. The project proposed to the summer student is the setting up of the CTTM and the porting of the software. Moreover, in order to monitor the CTTM Trigger board during the real data taking, the implementation of a new Quality Assurance (QA) code is also crucial, together wit...

  14. Safety Evaluation Report related to the operation of Comanche Peak Steam Electric Station, Units 1 and 2 (Docket Nos. 50-445 and 50-446). Supplement No. 11

    International Nuclear Information System (INIS)

    1985-05-01

    Supplement 11 to the Safety Evaluation Report for the Texas Utilities Electric Company application for a license to operate Comanche Peak Steam Electric Station, Units 1 and 2 (Docket Nos. 50-445, 50-446), located in Somervell County, Texas, has been jointly prepared by the Office of Nuclear Reactor Regulation and the Comanche Peak Technical Review Team (TRT) of the US Nuclear Regulatory Commission (NRC) and is in two parts. Part 1 (Appendix 0) of this supplement provides the results of the TRT's evaluation of approximately 124 concerns and allegations relating specifically to quality assurance and quality control (QA/QC) issues regarding construction proctices at the Comanche Peak facility. Part 2 (Appendix P) contains an overall summary and conclusion of the QA/QC aspects of the NRC Technical Review Team efforts as reported in supplemental Safety Evaluation Report SERs 7, 8, 9, and 10. Since QA/QC issues are also contained in each of the other supplements, the TRT considered that such a summary and conclusion from all supplements was necessary for a complete TRT description of QA/QC activities at Comanche Peak

  15. SU-E-T-148: Benchmarks and Pre-Treatment Reviews: A Study of Quality Assurance Effectiveness

    International Nuclear Information System (INIS)

    Lowenstein, J; Nguyen, H; Roll, J; Walsh, A; Tailor, A; Followill, D

    2015-01-01

    Purpose: To determine the impact benchmarks and pre-treatment reviews have on improving the quality of submitted clinical trial data. Methods: Benchmarks are used to evaluate a site’s ability to develop a treatment that meets a specific protocol’s treatment guidelines prior to placing their first patient on the protocol. A pre-treatment review is an actual patient placed on the protocol in which the dosimetry and contour volumes are evaluated to be per protocol guidelines prior to allowing the beginning of the treatment. A key component of these QA mechanisms is that sites are provided timely feedback to educate them on how to plan per the protocol and prevent protocol deviations on patients accrued to a protocol. For both benchmarks and pre-treatment reviews a dose volume analysis (DVA) was performed using MIM softwareTM. For pre-treatment reviews a volume contour evaluation was also performed. Results: IROC Houston performed a QA effectiveness analysis of a protocol which required both benchmarks and pre-treatment reviews. In 70 percent of the patient cases submitted, the benchmark played an effective role in assuring that the pre-treatment review of the cases met protocol requirements. The 35 percent of sites failing the benchmark subsequently modified there planning technique to pass the benchmark before being allowed to submit a patient for pre-treatment review. However, in 30 percent of the submitted cases the pre-treatment review failed where the majority (71 percent) failed the DVA. 20 percent of sites submitting patients failed to correct their dose volume discrepancies indicated by the benchmark case. Conclusion: Benchmark cases and pre-treatment reviews can be an effective QA tool to educate sites on protocol guidelines and to minimize deviations. Without the benchmark cases it is possible that 65 percent of the cases undergoing a pre-treatment review would have failed to meet the protocols requirements.Support: U24-CA-180803

  16. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.

    Science.gov (United States)

    Rampado, O; Garelli, E; Deagostini, S; Ropolo, R

    2006-06-07

    There is a growing interest in Gafchromic films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.

  17. QA

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    Koeberg's system for quality assurance was discussed with the Quality Assurance Programme Manager for Koeberg Construction. An American style of quality assurance, practised on French technology is used for Koeberg. The quality assurance that is practised at Koeberg, also affected other industries in South Africa

  18. Three-dimensional dose distribution in contrast-enhanced digital mammography using Gafchromic XR-QA2 films: Feasibility study

    International Nuclear Information System (INIS)

    Hwang, Yi-Shuan; Lin, Yu-Ying; Cheung, Yun-Chung; Tsai, Hui-Yu

    2014-01-01

    This study was aimed to establish three-dimensional dose distributions for contrast-enhanced digital mammography (CEDM) using self-developed Gafchromic XR-QA2 films. Dose calibration and distribution evaluations were performed on a full-field digital mammography unit with dual energy (DE) contrast-enhanced option. Strategy for dose calibration of films in the DE mode was based on the data obtained from common target/filter/kVp combinations used clinically and the dose response model modified from Rampado's model. Dose derived from films were also verified by measured data from an ionization chamber. The average difference of dose was 8.9% in the dose range for clinical uses. Three-dimensional dose distributions were estimated using triangular acrylic phantom equipped with the mammography system. Five pieces of film sheets were separately placed between the acrylic slabs to evaluate the dose distribution at different depths. After normalizing the dose in each pixel to the maximum dose at the top-center position of the acrylic, normalized dose distribution for transverse, coronal and sagittal planes, could thus be obtained. The depth dose distribution evaluated in this study may further serve as a reference for evaluating the patient glandular dose at different depths based on the entrance exposure information. - Highlights: • CEDM techniques can enhance contrast uptake areas and suppress background tissue. • Dose for the dual-energy acquisition is about 20% higher than standard mode. • A new method is proposed to estimate the 3D dose distribution in dual-energy CEDM. • Depth of normalized dose ratio of 0.5 is less than but near 1 cm in the DE mode

  19. Impact of Quality Assurance Rounds in a Canadian Radiation Therapy Department

    Energy Technology Data Exchange (ETDEWEB)

    Lefresne, Shilo; Olivotto, Ivo A.; Joe, Howard; Blood, Paul A. [Radiotherapy Department, BC Cancer Agency, Vancouver Island Centre, Vancouver, British Columbia (Canada); Radiotherapy Department, University of British Columbia, Vancouver, British Columbia (Canada); Olson, Robert A., E-mail: rolson2@bccancer.bc.ca [Radiotherapy Department, University of British Columbia, Vancouver, British Columbia (Canada); Radiotherapy Department, BC Cancer Agency, Centre for the North, Prince George, British Columbia (Canada)

    2013-03-01

    Purpose: Quality assurance (QA) programs aim to identify inconsistencies that may compromise patient care. Radiation treatment planning is a well-documented source of variation in radiation oncology, leading many organizations to recommend the implementation of QA rounds in which radiation therapy plans are peer reviewed. This study evaluates the outcome of QA rounds that have been conducted by a radiation therapy department since 2004. Methods and Materials: Prospectively documented records of QA rounds, from 2004 to 2010, were obtained. During rounds, randomly selected radiation therapy plans were peer reviewed and assigned a grade of A (adequate), B (minor suggestions of change to a plan for a future patient), or C (significant change required before the next fraction). The proportion of plans that received each recommendation was calculated, and the relationship between recommendations for each plan, tumor site, and mean years of experience of the radiation oncologist (RO) were explored. Chart reviews were performed for each plan that received a C. Results: During the study period, 1247 plans were evaluated; 6% received a B and 1% received a C. The mean RO years of experience were lower for plans graded C versus those graded A (P=.02). The tumor sites with the highest proportion of plans graded B or C were gastrointestinal (14%), lung (13%), and lymphoma (8%). The most common reasons for plans to receive a grade of C were inadequate target volume coverage (36%), suboptimal dose or fractionation (27%), errors in patient setup (27%), and overtreatment of normal tissue (9%). Conclusions: This study demonstrated that QA rounds are feasible and an important element of a radiation therapy department's QA program. Through peer review, plans that deviate from a department's expected standard can be identified and corrected. Additional benefits include identifying patterns of practice that may contribute to inconsistencies in treatment planning and the

  20. SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Brezovich, I; Popple, R; Duan, J; Huang, M; Benhabib, S; Shen, S; Cardan, R; Wu, X [University of Alabama Birmingham, Birmingham, AL (United States)

    2014-06-01

    Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

  1. SU-E-T-159: Evaluation of a Patient Specific QA Tool Based On TG119

    International Nuclear Information System (INIS)

    Ashmeg, S; Zhang, Y; O'Daniel, J; Yin, F; Ren, L

    2014-01-01

    Purpose: To evaluate the accuracy of a 3D patient specific QA tool by analysis of the results produced from associated software in homogenous phantom and heterogonous patient CT. Methods: IMRT and VMAT plans of five test suites introduced by TG119 were created in ECLIPSE on a solid water phantom. The ten plans -of increasing complexity- were delivered to Delta4 to give a 3D measurement. The Delta4's “Anatomy” software uses the measured dose to back-calculate the energy fluence of the delivered beams, which is used for dose calculation in a patient CT using a pencilbeam algorithm. The effect of the modulated beams' complexity on the accuracy of the “Anatomy” calculation was evaluated. Both measured and Anatomy doses were compared to ECLIPSE calculation using 3% - 3mm gamma criteria.We also tested the effect of heterogeneity by analyzing the results of “Anatomy” calculation on a Brain VMAT and a 3D conformal lung cases. Results: In homogenous phantom, the gamma passing rates were found to be as low as 74.75% for a complex plan with high modulation. The mean passing rates were 91.47% ± 6.35% for “Anatomy” calculation and 99.46% ± 0.62% for Delta4 measurements.As for the heterogeneous cases, the rates were 96.54%±3.67% and 83.87%±9.42% for Brain VMAT and 3D lung respectively. This increased error in the lung case could be due to the use of the pencil beam algorithm as opposed to the AAA used by ECLIPSE.Also, gamma analysis showed high discrepancy along the beam edge in the “Anatomy” calculated results. This suggests a poor beam modeling in the penumbra region. Conclusion: The results show various sources of errors in “Anatomy” calculations. These include beam modeling in the penumbra region, complexity of a modulated beam (shown in homogenous phantom and brain cases) and dose calculation algorithms (3D conformal lung case)

  2. SU-E-T-373: A Motorized Stage for Fast and Accurate QA of Machine Isocenter

    International Nuclear Information System (INIS)

    Moore, J; Velarde, E; Wong, J

    2014-01-01

    Purpose: Precision delivery of radiation dose relies on accurate knowledge of the machine isocenter under a variety of machine motions. This is typically determined by performing a Winston-Lutz test consisting of imaging a known object at multiple gantry/collimator/table angles and ensuring that the maximum offset is within specified tolerance. The first step in the Winston-Lutz test is careful placement of a ball bearing at the machine isocenter as determined by repeated imaging and shifting until accurate placement has been determined. Conventionally this is performed by adjusting a stage manually using vernier scales which carry the limitation that each adjustment must be done inside the treatment room with the risks of inaccurate adjustment of the scale and physical bumping of the table. It is proposed to use a motorized system controlled outside of the room to improve the required time and accuracy of these tests. Methods: The three dimensional vernier scales are replaced by three motors with accuracy of 1 micron and a range of 25.4mm connected via USB to a computer in the control room. Software is designed which automatically detects the motors and assigns them to proper axes and allows for small shifts to be entered and performed. Input values match calculated offsets in magnitude and sign to reduce conversion errors. Speed of setup, number of iterations to setup, and accuracy of final placement are assessed. Results: Automatic BB placement required 2.25 iterations and 13 minutes on average while manual placement required 3.76 iterations and 37.5 minutes. The average final XYZ offsets is 0.02cm, 0.01cm, 0.04cm for automatic setup and 0.04cm, 0.02cm, 0.04cm for manual setup. Conclusion: Automatic placement decreased time and repeat iterations for setup while improving placement accuracy. Automatic placement greatly reduces the time required to perform QA

  3. Quality assurance for the research and development of nuclear technology

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Kim, Young Sea; Lim, Nam Jin

    1991-01-01

    KAERI is carrying out several large nuclear R and D projects to achieve the indigenization of nuclear technology in Korea. In order to accomplish nuclear projects effectively, the KAERI-wide quality assurance system as well as project quality systems has been prepared for the coordination and effective implementation of various quality activities. The revision of KAERI QA Program Plan will help to establish and upgrade the effective and efficient KAERI-wide QA system. Technical support activities to the project QA program were performed in more systematic way. KAERI QA Committee was organized, and the meeting was held periodically to discuss and find out the optimum solution for the critical quality problems. Quality evaluation including internal audits was carried out to analyze the QA activities in the various projects and evlauation results was condensed to quality trend analysis. QA record preserving facility was built and was being used to maintain the QA records. The basic studies on the computer S/W QA, QA in R and D, quality costs analysis were also performed to upgrade the safety and reliability. (Author)

  4. Changing the image of quality assurance in research and development

    International Nuclear Information System (INIS)

    Melroy, P.E.

    1988-01-01

    The traditional image of quality assurance (QA) in a research and development (R and D) institution has been that of paper work. QA was often perceived as focusing on documentation rather than on contributions to productive work. The recent emphasis on regulation by outside groups and independent verification of QA systems has created an opportunity to reevaluate and change this image. The desired change is to create an understanding that when properly utilized, QA is essential to good project management and fully contributes to the success of technical programs. The change is being accomplished by sharpening the definition of QA systems of improved understanding by line organizations, developing a project QA in a structure that allows selective use of the NQA-1 standard, formation of a graded approach that simplifies QA for R and D projects, and an intense campaign to communicate the value of QA to laboratory personnel

  5. Inverse IMRT workflow process at Austin health

    International Nuclear Information System (INIS)

    Rykers, K.; Fernando, W.; Grace, M.; Liu, G.; Rolfo, A.; Viotto, A.; Mantle, C.; Lawlor, M.; Au-Yeung, D.; Quong, G.; Feigen, M.; Lim-Joon, D.; Wada, M.

    2004-01-01

    Full text: The work presented here will review the strategies adopted at Austin Health to bring IMRT into clinical use. IMRT is delivered using step and shoot mode on an Elekta Precise machine with 40 pairs of 1cm wide MLC leaves. Planning is done using CMS Focus/XiO. A collaborative approach for RO's, Physicists and RTs from concept to implementation was adopted. An overview will be given of the workflow for the clinic, the equipment used, tolerance levels and the lessons learned. 1. Strategic Planning for IMRT 2. Training a. MSKCC (New York) b.ESTRO (Amsterdam) c.Elekta (US and UK) 3. Linac testing and data acquisition a. Equipment and software review and selection b. Linac reliability/geometric and mechanical checks c. Draft Patient QA procedure d. EPI Image matching checks and procedures 4. Planning system checks a. export of dose matrix (options) b. dose calculation choices 5. IMRT Research Initiatives a. IMRT Planning Studies, Stabilisation, On-line Imaging 6. Equipment Procurement and testing a. Physics and Linac Equipment, Hardware, Software/Licences, Stabilisation 7. Establishing a DICOM Environment a. Prescription sending, Image transfer for EPI checks b. QA Files 8. Physics QA (Pre-Treatment) a.Clinical plan review; DVH checks b. geometry; dosimetry checks; DICOM checks c. 2D Distance to agreement; mm difference reports; Gamma function index 9. Documentation a.Protocol Development i. ICRU 50/62 reporting and prescribing b. QA for Physics c. QA for RT's d. Generation of a report for RO/patient history. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  6. The role and relevance of quality assurance to quality control

    International Nuclear Information System (INIS)

    Churchill, G.F.

    1989-01-01

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  7. Taxonomy-Based Approaches to Quality Assurance of Ontologies

    Directory of Open Access Journals (Sweden)

    Michael Halper

    2017-01-01

    Full Text Available Ontologies are important components of health information management systems. As such, the quality of their content is of paramount importance. It has been proven to be practical to develop quality assurance (QA methodologies based on automated identification of sets of concepts expected to have higher likelihood of errors. Four kinds of such sets (called QA-sets organized around the themes of complex and uncommonly modeled concepts are introduced. A survey of different methodologies based on these QA-sets and the results of applying them to various ontologies are presented. Overall, following these approaches leads to higher QA yields and better utilization of QA personnel. The formulation of additional QA-set methodologies will further enhance the suite of available ontology QA tools.

  8. Quality assurance of radiotherapy in the ongoing EORTC 22042–26042 trial for atypical and malignant meningioma: results from the dummy runs and prospective individual case Reviews

    International Nuclear Information System (INIS)

    Coskun, Mehtap; Straube, William; Hurkmans, Coen W; Melidis, Christos; Haan, Patricia F de; Villà, Salvador; Collette, Sandra; Weber, Damien C

    2013-01-01

    The ongoing EORTC 22042–26042 trial evaluates the efficacy of high-dose radiotherapy (RT) in atypical/malignant meningioma. The results of the Dummy Run (DR) and prospective Individual Case Review (ICR) were analyzed in this Quality Assurance (QA) study. Institutions were requested to submit a protocol compliant treatment plan for the DR and ICR, respectively. DR-plans (n=12) and ICR-plans (n=50) were uploaded to the Image-Guided Therapy QA Center of Advanced Technology Consortium server (http://atc.wustl.edu/) and were assessed prospectively. Major deviations were observed in 25% (n=3) of DR-plans while no minor deviations were observed. Major and minor deviations were observed in 22% (n=11) and 10% (n=5) of the ICR-plans, respectively. Eighteen% of ICRs could not be analyzed prospectively, as a result of corrupted or late data submission. CTV to PTV margins were respected in all cases. Deviations were negatively associated with the number of submitted cases per institution (p=0.0013), with a cutoff of 5 patients per institutions. No association (p=0.12) was observed between DR and ICR results, suggesting that DR’s results did not predict for an improved QA process in accrued brain tumor patients. A substantial number of protocol deviations were observed in this prospective QA study. The number of cases accrued per institution was a significant determinant for protocol deviation. These data suggest that successful DR is not a guarantee for protocol compliance for accrued patients. Prospective ICRs should be performed to prevent protocol deviations

  9. Quality planning for major plant design modifications

    International Nuclear Information System (INIS)

    Dulee, R.J.

    1988-01-01

    This paper reviews the approach and activities undertaken by Public Service Electric and Gas Company's (PSE and G's) nuclear quality assurance (QA) department to support major plant design modifications conducted during refueling outages at Salem Generating Station. It includes the planning and implementation of quality plans developed to provide both QA and quality control (QC) coverage of modification performed by contracted service organizations

  10. Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements

    NARCIS (Netherlands)

    Visser, R.; Wauben, D. J. L.; de Groot, M.; Godart, J.; Langendijk, J. A.; van t Veld, Aart A.; Korevaar, E. W.

    Purpose: Advanced radiotherapy treatments require appropriate quality assurance (QA) to verify 3D dose distributions. Moreover, increase in patient numbers demand efficient QA-methods. In this study, a time efficient method that combines model-based QA and measurement-based QA was developed; i.e.,

  11. Analysis of daily quality assurance tests for tomotherapy and two Varian linear accelerators - three months review

    International Nuclear Information System (INIS)

    Kushwaha, Pratishtha; Jaiswal, Deeksha; Dheera, A.; Upreti, Udita; Chaudhari, Suresh; Kinhikar, Rajesh; Deshpande, Deepak; Shrivastava, Shyam

    2016-01-01

    Daily quality assurance (QA) for high precision radiotherapy equipments is very important to maintain the mechanical and dosimetric accuracy for patient treatments. Gross deviations in these parameters may have an adverse impact on the delivery of the treatments to patients. We report the results of daily QA tests performed over a period of three months for two Varian linear accelerators and a Tomotherapy machine

  12. C-Reactive Protein Is an Important Biomarker for Prognosis Tumor Recurrence and Treatment Response in Adult Solid Tumors: A Systematic Review.

    Science.gov (United States)

    Shrotriya, Shiva; Walsh, Declan; Bennani-Baiti, Nabila; Thomas, Shirley; Lorton, Cliona

    2015-01-01

    A systematic literature review was done to determine the relationship between elevated CRP and prognosis in people with solid tumors. C-reactive protein (CRP) is a serum acute phase reactant and a well-established inflammatory marker. We also examined the role of CRP to predict treatment response and tumor recurrence. MeSH (Medical Subject Heading) terms were used to search multiple electronic databases (PubMed, EMBASE, Web of Science, SCOPUS, EBM-Cochrane). Two independent reviewers selected research papers. We also included a quality Assessment (QA) score. Reports with QA scores <50% were excluded. PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) methodology was utilized for this review (S1 PRISMA Checklist). 271 articles were identified for final review. There were 45% prospective studies and 52% retrospective. 264 had intermediate QA score (≥50% but <80%); Seven were adequate (80% -100%); A high CRP was predictive of prognosis in 90% (245/271) of studies-80% of the 245 studies by multivariate analysis, 20% by univariate analysis. Many (52%) of the articles were about gastrointestinal malignancies (GI) or kidney malignancies. A high CRP was prognostic in 90% (127 of 141) of the reports in those groups of tumors. CRP was also prognostic in most reports in other solid tumors primary sites. A high CRP was associated with higher mortality in 90% of reports in people with solid tumors primary sites. This was particularly notable in GI malignancies and kidney malignancies. In other solid tumors (lung, pancreas, hepatocellular cancer, and bladder) an elevated CRP also predicted prognosis. In addition there is also evidence to support the use of CRP to help decide treatment response and identify tumor recurrence. Better designed large scale studies should be conducted to examine these issues more comprehensively.

  13. Neurodegeneration Alters Metabolic Profile and Sirt 1 Signaling in High-Fat-Induced Obese Mice.

    Science.gov (United States)

    Lima, Leandro Ceotto Freitas; Saliba, Soraya Wilke; Andrade, João Marcus Oliveira; Cunha, Maria Luisa; Cassini-Vieira, Puebla; Feltenberger, John David; Barcelos, Lucíola Silva; Guimarães, André Luiz Sena; de-Paula, Alfredo Mauricio Batista; de Oliveira, Antônio Carlos Pinheiro; Santos, Sérgio Henrique Sousa

    2017-07-01

    Different factors may contribute to the development of neurodegenerative diseases. Among them, metabolic syndrome (MS), which has reached epidemic proportions, has emerged as a potential element that may be involved in neurodegeneration. Furthermore, studies have shown the importance of the sirtuin family in neuronal survival and MS, which opens the possibility of new pharmacological targets. This study investigates the influence of sirtuin metabolic pathways by examining the functional capacities of glucose-induced obesity in an excitotoxic state induced by a quinolinic acid (QA) animal model. Mice were divided into two groups that received different diets for 8 weeks: one group received a regular diet, and the other group received a high-fat diet (HF) to induce MS. The animals were submitted to a stereotaxic surgery and subdivided into four groups: Standard (ST), Standard-QA (ST-QA), HF and HF-QA. The QA groups were given a 250 nL quinolinic acid injection in the right striatum and PBS was injected in the other groups. Obese mice presented with a weight gain of 40 % more than the ST group beyond acquiring an insulin resistance. QA induced motor impairment and neurodegeneration in both ST-QA and HF-QA, although no difference was observed between these groups. The HF-QA group showed a reduction in adiposity when compared with the groups that received PBS. Therefore, the HF-QA group demonstrated a commitment-dependent metabolic pathway. The results suggest that an obesogenic diet does not aggravate the neurodegeneration induced by QA. However, the excitotoxicity induced by QA promotes a sirtuin pathway impairment that contributes to metabolic changes.

  14. Plutonium immobilization project development and testing quality assurance program description - February 1999

    International Nuclear Information System (INIS)

    MacLean, L. M.; Ziemba, J.

    1999-01-01

    Lawrence Livermore National Laboratory Immobilization Development and Testing organization (LLNL ID and T) is a Participant in the Plutonium Immobilization Project (PIP). The LLNL D and T has lead responsibilities for form characterization and qualification, ceramic form development, process/equipment development with plutonium, and process systems testing and validation for both conversion and immobilization. This work must be performed in accordance with the graded approach of a Quality Assurance (QA) Program. A QA Program has been developed at LLNL to meet the requirements of the DOE/MD Quality Assurance Requirements. The LLNL QA Program consists of a Quality Assurance Program Description (QAPD) and Quality Implementing Procedures. These documents interface and are a subset of the overall PIP QA Program Documents. The PIP QA Program is described in the PIP ID and T QA Plan, PIP QAPD, and QA Procedures. Other Participant Organizations also must document and describe their PIP compliant QA Programs in a QAPD and implementing procedures. The purpose of this LLNL QAPD is to describe the organization, management processes, QA Controls for Grading, functional responsibilities, levels of authority, and interfaces for those managing, performing, and assessing the adequacy of work

  15. Probabilistic Model for Laser Damage to the Human Retina

    Science.gov (United States)

    2012-03-01

    Ma1)); % Spot size into aqueous wa = sqrt((-Lambda /1e7)/(pi*n_corn*imag (1/ qa1))); % Aqueous propagation Ma2 = (T2(1,1)*qa1 + T2(1,2))/(T2(2,1)*qa1...T2(2,2)); qa2 = 1/( real (1/ Ma2 ) + i*imag (1/ Ma2 )); % Spot size into lens wL1 = sqrt((-Lambda /1e7)/(pi*n_aqua*imag (1/qa2))); % Front surface of

  16. Quality assurance and verification of the MACCS [MELCOR Accident Consequence Code System] code, Version 1.5

    International Nuclear Information System (INIS)

    Dobbe, C.A.; Carlson, E.R.; Marshall, N.H.; Marwil, E.S.; Tolli, J.E.

    1990-02-01

    An independent quality assurance (QA) and verification of Version 1.5 of the MELCOR Accident Consequence Code System (MACCS) was performed. The QA and verification involved examination of the code and associated documentation for consistent and correct implementation of the models in an error-free FORTRAN computer code. The QA and verification was not intended to determine either the adequacy or appropriateness of the models that are used MACCS 1.5. The reviews uncovered errors which were fixed by the SNL MACCS code development staff prior to the release of MACCS 1.5. Some difficulties related to documentation improvement and code restructuring are also presented. The QA and verification process concluded that Version 1.5 of the MACCS code, within the scope and limitations process concluded that Version 1.5 of the MACCS code, within the scope and limitations of the models implemented in the code is essentially error free and ready for widespread use. 15 refs., 11 tabs

  17. Quality assurance of Daya Bay Nuclear Power Plant in operations phase

    International Nuclear Information System (INIS)

    Cai Kangyuan

    2000-01-01

    The author introduces the responsibilities and functions of QA Department in Daya Bay Nuclear Power Station. It describes how QAD verifies the effectiveness of implementation of QA Program through its main QA activities: QA audits and QA surveillances. It also describes the quality deficiency classification, follow up and verification system, and its reporting system. It explains how QAD provides its supports and services to functional branches at the same time when it maintains its independence. At last it briefly introduces how QAD pushes Management Self Assessment activities in the Plant scope when performance based quality assurance is implemented and how it exercises real time QA monitoring activity during outage

  18. Clinical introduction of a linac head-mounted 2D detector array based quality assurance system in head and neck IMRT

    International Nuclear Information System (INIS)

    Korevaar, Erik W.; Wauben, David J.L.; Hulst, Peter C. van der; Langendijk, Johannes A.; Veld, Aart A. van't

    2011-01-01

    Background and purpose: IMRT QA is commonly performed in a phantom geometry but the clinical interpretation of the results in a 2D phantom plane is difficult. The main objective of our work is to move from film measurement based QA to 3D dose reconstruction in a patient CT scan. In principle, this could be achieved using a dose reconstruction method from 2D detector array measurements as available in the COMPASS system (IBA Dosimetry). The first step in the clinical introduction of this system instead of the currently used film QA procedures is to test the reliability of the dose reconstruction. In this paper we investigated the validation of the method in a homogeneous phantom with the film QA procedure as a reference. We tested whether COMPASS QA results correctly identified treatment plans that did or did not fulfil QA requirements in head and neck (H and N) IMRT. Materials and methods: A total number of 24 treatments were selected from an existing database with more than 100 film based H and N IMRT QA results. The QA results were classified as either good, just acceptable or clinically rejected (mean gamma index 0.5, respectively with 3%/3 mm criteria). Film QA was repeated and compared to COMPASS QA with a MatriXX detector measurement performed on the same day. Results: Good agreement was found between COMPASS reconstructed dose and film measured dose in a phantom (mean gamma 0.83 ± 0.09, 1SD with 1%/1 mm criteria, 0.33 ± 0.04 with 3%/3 mm criteria). COMPASS QA results correlated well with film QA, identifying the same patients with less good QA results. Repeated measurements with film and COMPASS showed changes in delivery after a modified MLC calibration, also visible in a standard MLC check in COMPASS. The time required for QA reduced by half by using COMPASS instead of film. Conclusions: Agreement of COMPASS QA results with film based QA supports its clinical introduction for a phantom geometry. A standard MLC calibration check is sensitive to <1 mm

  19. SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

    International Nuclear Information System (INIS)

    Ghebremedhin, A; Taber, M; Koss, P; Camargo, G; Patyal, B; Ebstein, S

    2016-01-01

    Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

  20. SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Ghebremedhin, A; Taber, M; Koss, P; Camargo, G; Patyal, B [Loma Linda University Medical Center, Loma Linda, CA (United States); Ebstein, S [Lexitek, Inc, Wellesley, MA (United States)

    2016-06-15

    Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

  1. Dose and energy dependence of response of Gafchromic (registered) XR-QA film for kilovoltage x-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Rampado, O; Garelli, E; Deagostini, S; Ropolo, R [Struttura Complessa fisica Sanitaria, Azienda Ospedaliera San Giovanni Battista, Corso Bramante 88, 10126 Turin (Italy)

    2006-06-07

    There is a growing interest in Gafchromic (registered) films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.

  2. Quality assurance system in electric power companies in Japan, (2)

    International Nuclear Information System (INIS)

    Hamaguchi, Shun-ichi

    1980-01-01

    The organization for the quality assurance in nuclear power plants of Kansai Electric Power Co., Inc. is introduced. It is still in investigation stage what quality assurance (QA) organization and system is the best. The QA investigation project team was organized in the form directly supervised by the Office of President. The purpose of QA in operation is to maintain the functions of power plants in good condition over the lifetime of the power plants after starting the operation, and the QA is divided into the following five items: (1) running operation, (2) check-up and maintenance, (3) in-service testing and inspection, (4) regular inspection, (5) general application control. The purposes and works to be implemented for these items are listed in a table, and explained in detail. The quality control in regular inspection is described about 4 stages is purchase order and contract, design, construction, and adjusting operation. Also further improvement of QA in operating nuclear power plants by implementing the next items has been decided to make the most of the teachings in the accident of Three Mile Island plant. (1) Reinforcement of operation management system, (2) completion of the training for operators, (3) clarification of the command system for operational control, and (4) change of installations and review of application. As seen in the above description, the important tasks in QA activities are the matching to the existing installations and the adjustment of interfaces with the equipments in operation. (Wakatsuki, Y.)

  3. Quality Assurance Challenges for Motion-Adaptive Radiation Therapy: Gating, Breath Holding, and Four-Dimensional Computed Tomography

    International Nuclear Information System (INIS)

    Jiang, Steve B.; Wolfgang, John; Mageras, Gig S.

    2008-01-01

    Compared with conventional three-dimensional (3D) conformal radiation therapy and intensity-modulated radiation therapy treatments, quality assurance (QA) for motion-adaptive radiation therapy involves various challenges because of the added temporal dimension. Here we discuss those challenges for three specific techniques related to motion-adaptive therapy: namely respiratory gating, breath holding, and four-dimensional computed tomography. Similar to the introduction of any other new technologies in clinical practice, typical QA measures should be taken for these techniques also, including initial testing of equipment and clinical procedures, as well as frequent QA examinations during the early stage of implementation. Here, rather than covering every QA aspect in depth, we focus on some major QA challenges. The biggest QA challenge for gating and breath holding is how to ensure treatment accuracy when internal target position is predicted using external surrogates. Recommended QA measures for each component of treatment, including simulation, planning, patient positioning, and treatment delivery and verification, are discussed. For four-dimensional computed tomography, some major QA challenges have also been discussed

  4. Is there a necessity for individual blood water corrections when conductivity-based access blood flow measurements are made?

    Science.gov (United States)

    Huang, Shih-Han S; Heidenheim, Paul A; Gallo, Kerri; Jayakumar, Saumya; Lindsay, Robert M

    2011-01-01

    Access blood water flow rate (Qaw) can be measured during hemodialysis using an online effective ionic dialysance (EID) methodology. Fresenius employ this methodology in their 2008K dialysis machine. The machine computer converts Qaw to an access blood flow rate (Fresenius Qa) using a generic blood water constant (BWC). We wished to validate this BWC. 18 patients had Fresenius Qa measurements using the EID and these were compared with a 'gold standard' ultrasound dilution methodology (Transonic Qa). Qa values were also obtained by removing the BWC from Fresenius Qa values to obtain the Qaw and recorrecting it with individualized patient factors using hematocrit and total protein values (HctTp Qa). The measurements were repeated after 1 h. There were no significant differences between Fresenius and Transonic, nor between HctTp and Transonic Qa values (p > 0.17). There were strong correlations between both sets of values (r > 0.856; p Fresenius Qa pairs (r = 0.573; p > 0.07). It was surmised that the BWC was not valid post-dialysis. The generic BWC is comparable to individualized blood water correction factors when Qa measures are made early in dialysis and prior to ultrafiltration treatment. Copyright © 2011 S. Karger AG, Basel.

  5. SU-E-J-78: Adaptive Planning Workflow in a Pencil Beam Scanning Proton Therapy Center

    Energy Technology Data Exchange (ETDEWEB)

    Blakey, M; Price, S; Robison, B; Niek, S; Moe, S; Renegar, J; Mark, A; Spenser, W [Provision Healthcare Partners, Knoxville, TN (United States)

    2015-06-15

    Purpose: The susceptibility of proton therapy to changes in patient setup and anatomy necessitates an adaptive planning process. With the right planning tools and clinical workflow, an adaptive plan can be created in a timely manner without adding significant workload to the treatment planning staff. Methods: In our center, a weekly QA CT is performed on most patients to assess setup, anatomy change, and tumor response. The QA CT is fused to the treatment planning CT, the contours are transferred via deformable registration, and the plan dose is recalculated on the QA CT. A physicist assesses the dose distribution, and an adaptive plan is requested based on tumor coverage or OAR dose changes. After the physician confirms or alters the deformed contours, a dosimetrist develops an adaptive plan using our TPS adaptation module. The plan is assessed for robustness and is then reviewed by the physician. Patient QA is performed within three days following the first adapted treatment. Results: Of the patients who received QA CTs, 19% required at least one adaptive plan (18.5% H&N, 18.5% brain, 11.1% breast, 14.8% chestwall, 14.8% lung, 18.5% pelvis and 3.8% abdomen). Of these patients, 14% went on a break, while the remainder was treated with the previous plan during the re-planning process. Adaptive plans were performed based on tumor shrinkage, anatomy change or positioning uncertainties for 37.9%, 44.8%, and 17.3% of the patients, respectively. On average, 3 full days are required between the QA CT and the first adapted plan treatment. Conclusion: Adaptive planning is a crucial component of proton therapy and should be applied to any site when the QA CT shows significant deviation from the plan. With an efficient workflow, an adaptive plan can be applied without delaying patient treatment or burdening the dosimetry and medical physics team.

  6. SU-E-J-78: Adaptive Planning Workflow in a Pencil Beam Scanning Proton Therapy Center

    International Nuclear Information System (INIS)

    Blakey, M; Price, S; Robison, B; Niek, S; Moe, S; Renegar, J; Mark, A; Spenser, W

    2015-01-01

    Purpose: The susceptibility of proton therapy to changes in patient setup and anatomy necessitates an adaptive planning process. With the right planning tools and clinical workflow, an adaptive plan can be created in a timely manner without adding significant workload to the treatment planning staff. Methods: In our center, a weekly QA CT is performed on most patients to assess setup, anatomy change, and tumor response. The QA CT is fused to the treatment planning CT, the contours are transferred via deformable registration, and the plan dose is recalculated on the QA CT. A physicist assesses the dose distribution, and an adaptive plan is requested based on tumor coverage or OAR dose changes. After the physician confirms or alters the deformed contours, a dosimetrist develops an adaptive plan using our TPS adaptation module. The plan is assessed for robustness and is then reviewed by the physician. Patient QA is performed within three days following the first adapted treatment. Results: Of the patients who received QA CTs, 19% required at least one adaptive plan (18.5% H&N, 18.5% brain, 11.1% breast, 14.8% chestwall, 14.8% lung, 18.5% pelvis and 3.8% abdomen). Of these patients, 14% went on a break, while the remainder was treated with the previous plan during the re-planning process. Adaptive plans were performed based on tumor shrinkage, anatomy change or positioning uncertainties for 37.9%, 44.8%, and 17.3% of the patients, respectively. On average, 3 full days are required between the QA CT and the first adapted plan treatment. Conclusion: Adaptive planning is a crucial component of proton therapy and should be applied to any site when the QA CT shows significant deviation from the plan. With an efficient workflow, an adaptive plan can be applied without delaying patient treatment or burdening the dosimetry and medical physics team

  7. The development of quality assurance program for cyberknife

    International Nuclear Information System (INIS)

    Jang, Ji Sun; Lee, Dong Han; Kang, Young Nam

    2006-01-01

    Standardization quality assurance (QA)program of Cyberknife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for Cyberknife and evaluation of the feasibility under applications. Considering the feature of constitution for systems and the therapeutic methodology of Cyberknife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two Cyberknife centers. The acceptable tolerance was based on the undertaking inspection list from the Cyberknife manufacturer and the QC results during last three years of two Cyberknife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. The current QA status of two Cyberknife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. It is considered that the developed QA program in this research could be established the standardization of QC methods for Cyberknife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy

  8. MO-FG-303-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Automating LINAC QA: Design and Testing of An Image Acquisition and Processing System Utilizing a Combination of Radioluminescent Phosphors, Embedded X-Ray Markers and Optical Measurements

    International Nuclear Information System (INIS)

    Jenkins, C; Naczynski, D; Yu, S; Xing, L

    2015-01-01

    Purpose: The recent development of phosphors to visualize radiation beams from linear accelerators (LINAC) offers a unique opportunity for evaluating radiation fields within the context of the treatment space. The purpose of this study was to establish an automated, self-calibrating prototype system for performing quality assurance (QA) measurements. Methods: A thin layer of Gd 2 O 2 S:Tb phosphor and fiducial markers were embedded on several planar faces of a custom-designed phantom. The phantom was arbitrarily placed near iso-center on the couch of a LINAC equipped with on-board megavoltage (MV) and kilovoltage (kV) imagers. A plan consisting of several beams and integrated image acquisitions was delivered. Images of the phantom were collected throughout the delivery. Salient features, such as fiducials, crosshairs and beam edges were then extracted from these images used to calibrate the system, adjust for variations in phantom placement, and perform measurements. Beam edges were visualized by imaging the light generated by the phosphor on the phantom enabling direct comparison with the light field and laser locations. Registration of MV, kV and optical image data was performed using the embedded fiducial markers, enabling comparison of imaging center locations. Measurements specified by TG-142 were calculated and compared with those obtained from a commercially available QA system. Results: The system was able to automatically extract the location of the fiducials, lasers, light field and radiation field from the acquired images regardless of phantom positioning. It was also able to automatically identify the locations of fiducial markers on kV and MV images. All collected measurements were within TG-142 guidelines. The difference between the prototype and commercially available system were less than 0.2 mm. Conclusion: The prototype system demonstrated the capability of accurately and autonomously evaluating various TG-142 parameters independent of operator

  9. Quick, efficient and effective patient-specific intensity-modulated radiation therapy quality assurance using log file and electronic portal imaging device

    Directory of Open Access Journals (Sweden)

    Rajesh Kumar

    2017-01-01

    Conclusions: The methodology demonstrated can be used for establishing the accuracy of trajectory log data and for independent routine IMRT QA by generating single number like gamma index to indicate pass or fail of an IMRT treatment plan. The QA indices such as numbers of occurrences of ≥2 mm error in LPS are found more than 5% of total number of occurrences; the dosimetric review of planned treatment is advisable.

  10. The software improvement process - tools and rules to encourage quality

    International Nuclear Information System (INIS)

    Sigerud, K.; Baggiolini, V.

    2012-01-01

    The Applications section of the CERN accelerator controls group has decided to apply a systematic approach to quality assurance (QA), the 'Software Improvement Process' - SIP. This process focuses on three areas: the development process itself, suitable QA tools, and how to practically encourage developers to do QA. For each stage of the development process we have agreed on the recommended activities and deliverables, and identified tools to automate and support the task. For example we do more code reviews. As peer reviews are resource intensive, we only do them for complex parts of a product. As a complement, we are using static code checking tools, like FindBugs and Checkstyle. We also encourage unit testing and have agreed on a minimum level of test coverage recommended for all products, measured using Clover. Each of these tools is well integrated with our IDE (Eclipse) and give instant feedback to the developer about the quality of their code. The major challenges of SIP have been to 1) agree on common standards and configurations, for example common code formatting and Javadoc documentation guidelines, and 2) how to encourage the developers to do QA. To address the second point, we have successfully implemented 'SIP days', i.e. one day dedicated to QA work to which the whole group of developers participates, and 'Top/Flop' lists, clearly indicating the best and worst products with regards to SIP guidelines and standards, for example test coverage. This paper presents the SIP initiative in more detail, summarizing our experience since two years and our future plans. (authors)

  11. TH-AB-201-12: Using Machine Log-Files for Treatment Planning and Delivery QA

    Energy Technology Data Exchange (ETDEWEB)

    Stanhope, C [Beaumont Health System, Royal Oak MI and Wayne State University, Detroit, MI (United States); Liang, J; Drake, D; Yan, D [Beaumont Health System, Royal Oak, MI (United States)

    2016-06-15

    stringent reconstructions. Following the aforementioned reconstruction recommendations, the log-file technique is capable of detecting delivery errors with equivalent accuracy and less noise than ArcCHECK QA. I am funded by an Elekta Research Grant.

  12. The role of governmental authorities in the surveillance activities for quality assurance of nuclear power plants

    International Nuclear Information System (INIS)

    Koutsky, J.; Hrdlicka, Z.; Beranek, J.; Becvar, J.

    1982-01-01

    The paper deals with the legal and organizational aspects as well as with the principles and procedures of the quality assurance (QA) system for particular equipment of nuclear power plants in Czechoslovakia, and the role of governmental authorities in surveillance activities. The basic governmental document is the Decree No.5 (1979) of the Czechoslovak Atomic Energy Commission (CzAEC) on the QA of particular equipment in nuclear power plants with regard to nuclear safety. It is divided into ten sections: opening provisions; classification of the particular equipment; QA programmes; procedures of final elaboration of QA programme documentation; QA principles; QA during design; QA during manufacture, procurement, installation and commissioning; in-service inspection; QA during repair and modifications; and concluding provisions. Governmental surveillance is based on Governmental Resolution No.195 (1977). According to this resolution, inspection must be carried out by an organization which is independent of the manufacturing and operating organizations. This inspection is performed by the Czechoslovak Atomic Energy Commission (for nuclear safety) and by the Czech Safety Work Office and the Slovak Safety Work Office (for technical safety), together with subordinated regional divisions. The activities of these authorities are discussed. (author)

  13. Quality assurance audit: a prospective non-randomised trial of chemotherapy and radiotherapy for osteolymphoma (TROG 99.04/ALLG LY02).

    Science.gov (United States)

    Christie, D; Le, T; Watling, K; Cornes, D; O'Brien, P; Hitchins, R

    2009-04-01

    A quality assurance (QA) audit of the Trans Tasman Radiation Oncology Group and Australasian Lymphoma and Leukaemia Group trial (TROG 99.04/ALLG LY02) began after accrual of 25 patients. The trial is a prospective non-randomized study of standard treatment for osteolymphoma. Data relating to informed consent, eligibility, chemotherapy and radiotherapy were reviewed. The audit showed a relatively low level of major variations from the protocol, with an overall rate of 3.6%. As this trial has accrued slowly over a long period, the concept of QA has also developed. Amendments were made to the protocol accordingly. In the future, QA procedures should be predetermined, conducted rapidly in real time, and appropriately funded in order to be relevant to the ongoing conduct of the trial.

  14. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    Science.gov (United States)

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of

  15. Legacy Management CERCLA Sites. Quality Assurance Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Donna L.

    2007-05-03

    S.M. Stoller Corporation is the contractor for the Technical Assistance Contract (TAC) for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) operations. Stoller employs a management system that applies to all programs, projects, and business management systems funded through DOE-LM task orders. The management system incorporates the philosophy, policies, and requirements of health and safety, environmental compliance, and quality assurance (QA) in all aspects of project planning and implementation. Health and safety requirements are documented in the Health and Safety Manual (STO 2), the Radiological Control Manual (STO 3), the Integrated Safety Management System Description (STO 10), and the Drilling Health and Safety Requirements (STO 14). Environmental compliance policy and requirements are documented in the Environmental Management Program Implementation Manual (STO 11). The QA Program is documented in the Quality Assurance Manual (STO 1). The QA Manual (STO 1) implements the specific requirements and philosophy of DOE Order 414.1C, Quality Assurance. This manual also includes the requirements of other standards that are regularly imposed by customers, regulators, or other DOE orders. Title 10 Code of Federal Regulations Part 830, “Quality Assurance Requirements,” ANSI/ASQC E4-2004, “Quality Systems for Environmental Data and Technology Programs – Requirements with Guidance for Use,” and ISO 14001-2004, “Environmental Management Systems,” have been included. These standards are similar in content. The intent of the QA Manual (STO 1) is to provide a QA management system that incorporates the requirements and philosophy of DOE and other customers within the QA Manual. Criterion 1, “Quality Assurance Program,” identifies the fundamental requirements for establishing and implementing the QA management system; QA Instruction (QAI) 1.1, “QA Program Implementation,” identifies the TAC organizations that have responsibility for

  16. Quality assurance of patients for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Yoon, Sang Min; Yi, Byong Yong; Choi, Eun Kyung; Kim, Jong Hoon; Ahn, Seung Do; Lee, Sang Wook

    2002-01-01

    To establish and verify the proper and the practical IMRT (intensity-modulated radiation therapy) patient QA (Quality Assurance). An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step QA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record and Verify system make up the treatment delivery QA procedure. The point dose measurement results of 10 cases showed good agreement with the RTP calculation within 3%. One case showed more than a 3% difference and the other case showed more than 5%, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be performed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure

  17. Legacy Management CERCLA Sites. Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    2007-01-01

    S.M. Stoller Corporation is the contractor for the Technical Assistance Contract (TAC) for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) operations. Stoller employs a management system that applies to all programs, projects, and business management systems funded through DOE-LM task orders. The management system incorporates the philosophy, policies, and requirements of health and safety, environmental compliance, and quality assurance (QA) in all aspects of project planning and implementation. Health and safety requirements are documented in the Health and Safety Manual (STO 2), the Radiological Control Manual (STO 3), the Integrated Safety Management System Description (STO 10), and the Drilling Health and Safety Requirements (STO 14). Environmental compliance policy and requirements are documented in the Environmental Management Program Implementation Manual (STO 11). The QA Program is documented in the Quality Assurance Manual (STO 1). The QA Manual (STO 1) implements the specific requirements and philosophy of DOE Order 414.1C, Quality Assurance. This manual also includes the requirements of other standards that are regularly imposed by customers, regulators, or other DOE orders. Title 10 Code of Federal Regulations Part 830, 'Quality Assurance Requirements', ANSI/ASQC E4-2004, 'Quality Systems for Environmental Data and Technology Programs - Requirements with Guidance for Use', and ISO 14001-2004, 'Environmental Management Systems', have been included. These standards are similar in content. The intent of the QA Manual (STO 1) is to provide a QA management system that incorporates the requirements and philosophy of DOE and other customers within the QA Manual. Criterion 1, 'Quality Assurance Program', identifies the fundamental requirements for establishing and implementing the QA management system; QA Instruction (QAI) 1.1, 'QA Program Implementation', identifies the TAC organizations that have responsibility for implementing the QA

  18. Breaking down the communication barrier.

    Science.gov (United States)

    Hawkins, R A

    1991-01-01

    Dr. Hawkins addresses the problem of how QA managers can best persuade physicians of the importance of QA programs. Since communication is the basis of educating clinicians, the author analyzes the diametrically opposite perspectives of QA managers and physicians even as they pursue the common goal of quality healthcare. While doctors are primarily loyal to patients and peers with an immediate care focus, process-oriented QA managers emphasize the institution and its longer-term goals. To overcome physician resistance to change, Dr. Hawkins offers an adult learner model that stresses understanding the medical staff's viewpoint, negotiation and respect. Physicians are enthusiastic about QA when it helps solve "the endemic daily system problems." The author concludes by recommending that QA managers join physicians on their clinical rounds to bridge the gap between their different approaches.

  19. Krsko NPP Quality Assurance Plan Application to Nuclear Safety Upgrade Projects (PCFV System and PAR System)

    International Nuclear Information System (INIS)

    Biscan, Romeo; Fifnja, Igor

    2014-01-01

    Nuklearna Elektrarna Krsko (NEK) has undertaken Nuclear Safety Upgrade Projects as a safety improvement driven by the lessons learned from the Fukushima-Daiichi Accident. Among other projects, new modification 1008-VA-L Passive Containment Filtered Vent (PCFV) System has been installed which acts as the last barrier minimizing the release of radioactive material into the environment in case of failure of all safety systems, and to insure containment integrity during beyond design basis accidents (BDBA). In addition, modification 1002-GH-L Severe Accident Hydrogen Control System (PAR) has been implemented to prevent and mitigate the consequences of explosive gas generation (hydrogen and carbon monoxide) in case of reactor core melting. To ensure containment integrity for all design basis accidents (DBA) and BDBA conditions, NEK has eliminated existing safety-related electrical recombiners, replaced them with two safety-related passive autocatalytic recombiners (PARs) and added 20 new PARs designed for the BDBA conditions. Krsko NPP Quality Assurance Plan has been applied to Nuclear Safety Upgrade Projects (PCFV System and PAR System) through the following activities: · Internal audit of modification process was performed. · Supplier audits were performed to evaluate QA program efficiency of the main design organization and engineering organizations. · Evaluation and approval of Suppliers were performed. · QA engineer was involved in the review and approval of 1008-VA-L and 1002-GH-L modification documentation (Conceptual Design Package, Design Modification Package, Installation Package, Field Design Change Request, Problem/Deficiency Report, and Final Documentation Package). · Purchasing documentation for modifications 1008-VA-L and 1002-GH-L (technical specifications, purchase orders) has been verified and approved by QA. · QA and QC engineers were involved in oversight of production and testing of the new 1008-VA-L and 1002-GH-L plant components.

  20. Quality assurance: an independent safety assessment of Department of Energy nuclear reactor facilities

    International Nuclear Information System (INIS)

    Frankhouser, W.L.; Bass, W. Jr.; Langston, M.E.

    1981-02-01

    This report presents the assessments of QA programs at eight DOE reactor sites as performed by three members of the NFPQT Support Team. A summation of assessments is presented. That summation includes discussion of findings and recommendations for follow-on actions. The detailed record of contractor-by-contractor reviews is provided. A discussion of the approach in performing the QA assessments is presented, and the basis and limitations of the assessments are discussed

  1. Laboratory quality assurance and its role in nuclear fuel reprocessing and refabrication

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1977-09-01

    For the overall quality assurance (QA) program to be fully effective, the principles of QA must be applied to the operation of the analytical chemistry laboratory itself. This paper shows how QA is used at HEDL to produce confidence in each analytical result. Use of QA has resulted in the following benefits: poor laboratory practices have been found and eliminated, and an already adequate record system was improved even further

  2. Implementing hospital quality assurance policies in Iran: balancing licensing, annual evaluation, inspections and quality management systems.

    Science.gov (United States)

    Aghaei Hashjin, Asgar; Delgoshaei, Bahram; Kringos, Dionne S; Tabibi, Seyed Jamaladin; Manouchehri, Jila; Klazinga, Niek S

    2015-01-01

    The purpose of this paper is to provide an overview of applied hospital quality assurance (QA) policies in Iran. A mixed method (quantitative data and qualitative document analysis) study was carried out between 1996 and 2010. The QA policy cycle forms a tight monitoring system to assure hospital quality by combining mandatory and voluntary methods in Iran. The licensing, annual evaluation and grading, and regulatory inspections statutorily implemented by the government as a national package to assure and improve hospital care quality, while implementing quality management systems (QMS) was voluntary for hospitals. The government's strong QA policy legislation role and support has been an important factor for successful QA implementation in Iran, though it may affected QA assessment independency and validity. Increased hospital evaluation independency and repositioning, updating standards, professional involvement and effectiveness studies could increase QA policy impact and maturity. The study highlights the current QA policy implementation cycle in Iranian hospitals. It provides a basis for further quality strategy development in Iranian hospitals and elsewhere. It also raises attention about finding the optimal balance between different QA policies, which is topical for many countries. This paper describes experiences when implementing a unique approach, combining mandatory and voluntary QA policies simultaneously in a developing country, which has invested considerably over time to improve hospital quality. The experiences with a mixed obligatory/voluntary approach and comprehensive policies in Iran may contain lessons for policy makers in developing and developed countries.

  3. TLD Quality Assurance (QA) network in radiotherapy and radiology in the Czech Republic

    International Nuclear Information System (INIS)

    Kroutilikova, D.; Novak, N.; Novotny, J.

    2002-01-01

    Full text: The Czech TLD QA network was established in 1997, as a part of the External Auditing Group (EAG) originated in 1995, in order to perform an independent quality audit in external beam therapy for two purposes: a) to unify the dose within radiotherapy departments, b) to impact state supervision. On basis of a good experience with this network in radiotherapy, new methods were developed to expand the network also to radiology in order to simplify the operation of state supervision. The TLD QA network in dental radiology has been brought into practice in 2001. Both the TLD audits performed in radiotherapy and radiology are realized via mailed dosimetry. In radiotherapy, two modes of the audit are used. Basic mode of TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. According to Czech regulations every beam must be checked in this way at least once during two years' period. Advanced mode consists of measurements under both reference and non- reference conditions using Leuven multi-purpose phantom for photon beams. It enables to check a substantial part of the treatment planning process inclusive of final dose realization of the planned radiotherapy. The radiotherapy centers are instructed to deliver absorbed dose of 2 Gy to the TLDs on central beam axis based on calculated treatment time or monitor units by their treatment planning system for a particular treatment set-up. In this way the TLD measured doses are compared with the calculated ones. Deviations of ±3% are considered acceptable for both basic and advanced modes of the audit, deviations up to ±6% are still tolerable, but new audit is repeated as soon as possible to solve the dosimetry problem. Deviations above ±6% leads immediately to investigation by EAG. There are 34 centers in the Czech Republic, which provide external beam radiotherapy. Since they must undergo the basic TLD audit regularly every

  4. Floristic diversity of the shrub-arboreal stratum of homegardens in the Mariana re-settlement, Tocantins State, Brazil

    Directory of Open Access Journals (Sweden)

    Ícaro Gonçalves Santos

    2017-12-01

    Full Text Available The objective was to analyze the floristic, diversity and equability of the tree shrub stratum of home gardens (QA in Mariana re-settlement located between Palmas and Porto Nacional municipalities in Tocantins State, Brazil. Three 20 x 30 m plots were installed in each home garden, totalizing 0.72 ha of sampled area. All shrub-tree individuals had its circumference at 1.3 m above ground level (CBH measured when CBH ≥ 10 cm. A total of 477 individuals, 81 species, 34 families and 73 genera were verified in all QA. Shannon diversity index (H’ was 3.68 and Pielou equability indice (J’ was 0.83, for all sampled area. Individually, QA1, QA2, QA3 and QA4 presented H’ = 2.52; 3.27; 2.66 and 2.94, and J’ = 0.78; 0.90; 0.77 and 0.85, respectively. It was possible to infer that the studied QA showed high richness and diversity, evidencing great environmental heterogeneity and low ecological dominance.

  5. Quality Assurance Issues for Therapeutic Application of Radioactive Microspheres

    International Nuclear Information System (INIS)

    Dezarn, William A.

    2008-01-01

    The use of radioactive microspheres for the treatment of hepatic cancer is a procedure that raises unique quality assurance (QA) concerns. The greatest of these concerns is the coordination of the responsibilities among the medical team members from interventional radiology, radiation oncology, nuclear medicine, and medical physics. A single QA practice and procedure guidance document does not currently exist that addresses the range of issues of concern for radioactive microspheres. A small sampling of QA issues of concern include imaging QA, procedure-specific imaging protocols, detector calibration, activity measurement, radiation safety, patient dose calculations, and patient-specific QA. Some of the items listed have historically been the responsibility of a single team member, and other items have been concerns for all. A procedural overview of the therapeutic application of radioactive microspheres is presented to illustrate the broad, team-based QA approach necessary to safely and effectively deliver this type of treatment. From this overview, the reader will be able to customize the local QA protocol to meet the local division of responsibilities

  6. Manual on training, qualification and certification of quality assurance personnel

    International Nuclear Information System (INIS)

    1986-01-01

    The Manual is applicable to those participants in a nuclear power project who are associated with establishment and implementation of the various quality assurance (QA) programmes during the life cycle of the project. It provides examples of typical QA functions to be undertaken and the associated qualification requirements, training programmes, training techniques and methods of certification of personnel implementing these functions. The necessary qualification and training requirements and practices for QA personnel are dependent primarily on the functions or activities to be performed. The two main functions of the QA unit noted previously as (a) ensuring QA programme establishment and execution and (b) verifying that activities have been correctly performed have been found in practice to require different qualifications and training of personnel. Therefore, for the purpose of this Manual the QA personnel may be classified in two groups who perform: QA programmatic and evaluation functions; Inspection and test functions. These titles do not necessarily represent separate or individual organizational groups or units and may be composed of one or of several different organizations

  7. Quality assurance in Spain

    International Nuclear Information System (INIS)

    Villate, J.

    1980-01-01

    The first part of this lecture is devoted to present the energy program in Spain and the three generations of nuclear plants. The evolution of QA is outlined pointing out how IAEA Codes of Practice on QA is now a requirement and also how USA regulations, codes and standards have constituted, up to now, the main framework to develop QA activities in Spain. A general idea is given of the Spanish program of courses to qualify the personnel to be involved in QA tasks in nuclear power plants. Finally a general scheme is given, emphasizing the three main aspects: design, procurement and fabrication; construction (QA on site). (orig./RW)

  8. SU-E-T-316: The Design of a Risk Index Method for 3D Patient Specific QA

    Energy Technology Data Exchange (ETDEWEB)

    Cho, W; Wu, H [Seoul National University Hospital, Seoul (Korea, Republic of); Xing, L [Stanford University, Stanford, CA (United States); Suh, T [Catholic UniversityMedical College, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: To suggest a new guidance for the evaluation of 3D patient specific QA, a structure-specific risk-index (RI) method was designed and implemented. Methods: A new algorithm was designed to assign the score of Pass, Fail or Pass with Risk to all 3D voxels in each structure by improving a conventional Gamma Index (GI) algorithm, which implied the degree of the risk of under-dose to the treatment target or over-dose to the organ at risks (OAR). Structure-specific distance to agreement (DTOA), dose difference and minimum checkable dose were applied to the GI algorithm, and additional parameters such as dose gradient factor and dose limit of structures were used to the RI method. Maximum passing rate (PR) and minimum PR were designed and calculated for each structure with the RI method. 3D doses were acquired from a spine SBRT plan by simulating the shift of beam iso-center, and tested to show the feasibility of the suggested method. Results: When the iso-center was shifted by 1 mm, 2 mm, and 3 mm, the PR of conventional GI method between shifted and non-shifted 3D doses were 99.9%, 97.4%, and 89.7% for PTV, 99.8%, 84.8%, and 63.2% for spinal cord, and 100%, 99.5%, 91.7% for right lung. The minimum PRs from the RI method were 98.9%, 96.9%, and 89.5% for PTV, and 96.1%, 79.3%, 57.5% for spinal cord, and 92.5%, 92.0%, 84.4% for right lung, respectively. The maximum PRs from the RI method were equal or less than the PRs from the conventional GI evaluation. Conclusion: Designed 3D RI method showed more strict acceptance level than the conventional GI method, especially for OARs. The RI method is expected to give the degrees of risks in the delivered doses, as well as the degrees of agreements between calculated 3D doses and measured (or simulated) 3D doses.

  9. SU-E-T-316: The Design of a Risk Index Method for 3D Patient Specific QA

    International Nuclear Information System (INIS)

    Cho, W; Wu, H; Xing, L; Suh, T

    2014-01-01

    Purpose: To suggest a new guidance for the evaluation of 3D patient specific QA, a structure-specific risk-index (RI) method was designed and implemented. Methods: A new algorithm was designed to assign the score of Pass, Fail or Pass with Risk to all 3D voxels in each structure by improving a conventional Gamma Index (GI) algorithm, which implied the degree of the risk of under-dose to the treatment target or over-dose to the organ at risks (OAR). Structure-specific distance to agreement (DTOA), dose difference and minimum checkable dose were applied to the GI algorithm, and additional parameters such as dose gradient factor and dose limit of structures were used to the RI method. Maximum passing rate (PR) and minimum PR were designed and calculated for each structure with the RI method. 3D doses were acquired from a spine SBRT plan by simulating the shift of beam iso-center, and tested to show the feasibility of the suggested method. Results: When the iso-center was shifted by 1 mm, 2 mm, and 3 mm, the PR of conventional GI method between shifted and non-shifted 3D doses were 99.9%, 97.4%, and 89.7% for PTV, 99.8%, 84.8%, and 63.2% for spinal cord, and 100%, 99.5%, 91.7% for right lung. The minimum PRs from the RI method were 98.9%, 96.9%, and 89.5% for PTV, and 96.1%, 79.3%, 57.5% for spinal cord, and 92.5%, 92.0%, 84.4% for right lung, respectively. The maximum PRs from the RI method were equal or less than the PRs from the conventional GI evaluation. Conclusion: Designed 3D RI method showed more strict acceptance level than the conventional GI method, especially for OARs. The RI method is expected to give the degrees of risks in the delivered doses, as well as the degrees of agreements between calculated 3D doses and measured (or simulated) 3D doses

  10. Statistical variability and confidence intervals for planar dose QA pass rates

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Daniel W.; Nelms, Benjamin E.; Attwood, Kristopher; Kumaraswamy, Lalith; Podgorsak, Matthew B. [Department of Physics, State University of New York at Buffalo, Buffalo, New York 14260 (United States) and Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Biostatistics, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Molecular and Cellular Biophysics and Biochemistry, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States) and Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14214 (United States)

    2011-11-15

    techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

  11. Radiation oncology and medical physicists quality assurance in British Columbia Cancer Agency Provincial Prostate Brachytherapy Program.

    Science.gov (United States)

    Keyes, Mira; Morris, William James; Spadinger, Ingrid; Araujo, Cynthia; Cheung, Arthur; Chng, Nick; Crook, Juanita; Halperin, Ross; Lapointe, Vince; Miller, Stacy; Pai, Howard; Pickles, Tom

    2013-01-01

    To describe in detail British Columbia (BC) Cancer Agency (BCCA) Provincial Prostate Brachytherapy (PB) Quality Assurance (QA) Program. The BCCA PB Program was established in 1997. It operates as one system, unified and supported by electronic and information systems, making it a single PB treatment provider for province of BC and Yukon. To date, >4000 patients have received PB (450 implants in 2011), making it the largest program in Canada. The Program maintains a large provincial prospective electronic database with records on all patients, including disease characteristics, risk stratification, pathology, preplan and postimplant dosimetric data, follow-up of prostate-specific antigen, and toxicity outcomes. QA was an integral part of the program since its inception. A formal QA Program was established in 2002, with key components that include: unified eligibility criteria and planning system, comprehensive database, physics and oncologist training and mentorship programs, peer review process, individual performance outcomes and feedback process, structured continuing education and routine assessment of the program's dosimetry, toxicity and prostate-specific antigen outcomes, administration and program leadership that promotes a strong culture of patient safety. The emphasis on creating a robust, broad-based network of skilled providers has been achieved by the program's requirements for training, education, and the QA process. The formal QA process is considered a key factor for the success of cancer control outcomes achieved at BCCA. Although this QA model may not be wholly transferable to all PB programs, some of its key components may be applicable to other programs to ensure quality in PB and patient safety. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  12. Analysis of a comprehensive quality assurance program with computer-enhanced monitors

    International Nuclear Information System (INIS)

    Arenson, R.L.; Mintz, M.C.; Goldstein, E.; Stevens, J.F.; Jovais, C.

    1987-01-01

    The authors' quality assurance (QA) program provides communication pathways among its constituent committees, which include patient care, professional review, medical staff, missed case, quality control, safety, and management committees. The QA monitors are based on data from these committees but also include data from the information management system, such as patient delays, contrast reactions, incidents, complications, time-flow analyses, film library retrieval, cancellations, missing reports, and missing clinical data. Committee data include complaints, missed diagnoses, patient identification problems, and equipment failure. The QA monitors have now been incorporated into summary reports as part of their computer networks. A systematic method for follow-up ensures corrective action and documentation. Examples of improved quality of care resulting from this approach includes reductions in delays for report signature and in repeat films

  13. EMODnet Thematic Lot n° 4 - Chemistry

    DEFF Research Database (Denmark)

    Beckers, Jean-Marie; Buga, Luminita; Debray, Noelie

    2015-01-01

    Data quality assurance and quality control (QA/QC) is an important issue in oceanographic data management, especially for the creation of multidisciplinary and comprehensive databases which include data from different and/or unknown origin covering long time periods. The data-collection methods i...... inconsistent data quality flags and the need for coordination and harmonization of practices. A dedicated workshop was organized to review the different practices and agree on a common methodology for data QA/QC and Diva products generation for EMODnet Chemistry....... will contribute considerably to the validation of large data collections. This report intends to be a reference manual for EMODnet Chemistry data QA/QC and the subsequent product generation. In fact, during the first data validation loop, each region adopted its own protocol and the results showed many...

  14. SU-F-BRD-13: Quantum Annealing Applied to IMRT Beamlet Intensity Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Nazareth, D [Roswell Park Cancer Institute, Buffalo, NY (United States); Spaans, J [Hawarden, IA (United States)

    2014-06-15

    Purpose: We report on the first application of quantum annealing (QA) to the process of beamlet intensity optimization for IMRT. QA is a new technology, which employs novel hardware and software techniques to address various discrete optimization problems in many fields. Methods: We apply the D-Wave Inc. proprietary hardware, which natively exploits quantum mechanical effects for improved optimization. The new QA algorithm, running on this hardware, is most similar to simulated annealing, but relies on natural processes to directly minimize the free energy of a system. A simple quantum system is slowly evolved into a classical system, representing the objective function. To apply QA to IMRT-type optimization, two prostate cases were considered. A reduced number of beamlets were employed, due to the current QA hardware limitation of ∼500 binary variables. The beamlet dose matrices were computed using CERR, and an objective function was defined based on typical clinical constraints, including dose-volume objectives. The objective function was discretized, and the QA method was compared to two standard optimization Methods: simulated annealing and Tabu search, run on a conventional computing cluster. Results: Based on several runs, the average final objective function value achieved by the QA was 16.9 for the first patient, compared with 10.0 for Tabu and 6.7 for the SA. For the second patient, the values were 70.7 for the QA, 120.0 for Tabu, and 22.9 for the SA. The QA algorithm required 27–38% of the time required by the other two methods. Conclusion: In terms of objective function value, the QA performance was similar to Tabu but less effective than the SA. However, its speed was 3–4 times faster than the other two methods. This initial experiment suggests that QA-based heuristics may offer significant speedup over conventional clinical optimization methods, as quantum annealing hardware scales to larger sizes.

  15. Conformational heterogeneity of the bacteriopheophytin electron acceptor HA in reaction centers from Rhodopseudomonas viridis revealed by Fourier transform infrared spectroscopy and site-directed mutagenesis.

    Science.gov (United States)

    Breton, J; Bibikova, M; Oesterhelt, D; Nabedryk, E

    1999-08-31

    The light-induced Fourier transform infrared (FTIR) difference spectra corresponding to the photoreduction of either the HA bacteriopheophytin electron acceptor (HA-/HA spectrum) or the QA primary quinone (QA-/QA spectrum) in photosynthetic reaction centers (RCs) of Rhodopseudomonas viridis are reported. These spectra have been compared for wild-type (WT) RCs and for two site-directed mutants in which the proposed interactions between the carbonyls on ring V of HA and the RC protein have been altered. In the mutant EQ(L104), the putative hydrogen bond between the protein and the 9-keto C=O of HA should be affected by changing Glu L104 to a Gln. In the mutant WF(M250), the van der Waals interactions between Trp M250 and the 10a-ester C=O of HA should be modified. The characteristic effects of both mutations on the FTIR spectra support the proposed interactions and allow the IR modes of the 9-keto and 10a-ester C=O of HA and HA- to be assigned. Comparison of the HA-/HA and QA-/QA spectra leads us to conclude that the QA-/QA IR signals in the spectral range above 1700 cm-1 are largely dominated by contributions from the electrostatic response of the 10a-ester C=O mode of HA upon QA photoreduction. A heterogeneity in the conformation of the 10a-ester C=O mode of HA in WT RCs, leading to three distinct populations of HA, appears to be related to differences in the hydrogen-bonding interactions between the carbonyls of ring V of HA and the RC protein. The possibility that this structural heterogeneity is related to the observed multiexponential kinetics of electron transfer and the implications for primary processes are discussed. The effect of 1H/2H exchange on the QA-/QA spectra of the WT and mutant RCs shows that neither Glu L104 nor any other exchangeable carboxylic residue changes appreciably its protonation state upon QA reduction.

  16. SU-F-BRD-13: Quantum Annealing Applied to IMRT Beamlet Intensity Optimization

    International Nuclear Information System (INIS)

    Nazareth, D; Spaans, J

    2014-01-01

    Purpose: We report on the first application of quantum annealing (QA) to the process of beamlet intensity optimization for IMRT. QA is a new technology, which employs novel hardware and software techniques to address various discrete optimization problems in many fields. Methods: We apply the D-Wave Inc. proprietary hardware, which natively exploits quantum mechanical effects for improved optimization. The new QA algorithm, running on this hardware, is most similar to simulated annealing, but relies on natural processes to directly minimize the free energy of a system. A simple quantum system is slowly evolved into a classical system, representing the objective function. To apply QA to IMRT-type optimization, two prostate cases were considered. A reduced number of beamlets were employed, due to the current QA hardware limitation of ∼500 binary variables. The beamlet dose matrices were computed using CERR, and an objective function was defined based on typical clinical constraints, including dose-volume objectives. The objective function was discretized, and the QA method was compared to two standard optimization Methods: simulated annealing and Tabu search, run on a conventional computing cluster. Results: Based on several runs, the average final objective function value achieved by the QA was 16.9 for the first patient, compared with 10.0 for Tabu and 6.7 for the SA. For the second patient, the values were 70.7 for the QA, 120.0 for Tabu, and 22.9 for the SA. The QA algorithm required 27–38% of the time required by the other two methods. Conclusion: In terms of objective function value, the QA performance was similar to Tabu but less effective than the SA. However, its speed was 3–4 times faster than the other two methods. This initial experiment suggests that QA-based heuristics may offer significant speedup over conventional clinical optimization methods, as quantum annealing hardware scales to larger sizes

  17. A prolog implementation of pattern search to optimize software quality assurance

    OpenAIRE

    Buzzard, Raymond Karl

    1990-01-01

    Approved for public release, distribution is unlimited Quality Assurance (QA) is a critical factor in the development of successful software systems. Through the use of various QA tools, project managers can ensure that a desired level of performance and reliability is built into the system. However, these tools are not without cost. Project managers must weight all QA costs and benefits for each development environment before weigh all QA costs and benefits for each development environmen...

  18. SU-G-TeP4-02: A Method for Evaluating the Direct Impact of Failed IMRT QAs On Patient Dose

    International Nuclear Information System (INIS)

    Geneser, S; Butkus, M

    2016-01-01

    Purpose: We developed a method to calculate patient doses corresponding to IMRT QA measurements in order to determine and assess the actual dose delivered for plans with failed (or borderline) IMRT QA. This work demonstrates the feasibility of automatically computing delivered patient dose from portal dosimetry measurements in the Varian TPS system, which would provide a valuable and clinically viable IMRT QA tool for physicists and physicians. Methods: IMRT QA fluences were measured using portal dosimetry, processed using in-house matlab software, and imported back into Eclipse to calculate dose on the planning CT. To validate the proposed workflow, the Eclipse calculated portal dose for a 5-field sliding window prostate boost plan was processed as described above. The resulting dose was compared to the planned dose and found to be within 0.5 Gy. Two IMRT QA results for the prostate boost plan (one that failed and one that passed) were processed and the resulting patient doses were evaluated. Results: The max dose difference between IMRT QA #1 and the original planned and approved dose is 4.5 Gy, while the difference between the planned and IMRT QA #2 dose is 4.0 Gy. The inferior portion of the PTV is slightly underdosed in both plans, and the superior portion is slightly overdosed. The patient dose resulting from IMRT QA #1 and #2 differs by only 0.5 Gy. With this new information, it may be argued that the evaluated plan alteration to obtain passing gamma analysis produced clinically irrelevant differences. Conclusion: Evaluation of the delivered QA dose on the planning CT provides valuable information about the clinical relevance of failed or borderline IMRT QAs. This particular workflow demonstrates the feasibility of pushing the measured IMRT QA portal dosimetry results directly back onto the patient planning CT within the Varian system.

  19. Contribution of quality assurance to effective nuclear power plant operation

    International Nuclear Information System (INIS)

    Raisic, N.

    1984-01-01

    The regulatory requirements related to quality assurance (QA) serve as an effective mechanism in establishing and implementing the QA programme during the design, construction and operation of nuclear power plants. However, these requirements only relate to the equipment and activities concerning the safety of nuclear power plants; the decision as to their implementation on other non-safety-related equipment is left to the plant management. As a result, operation statistics show that the safety-related systems are performing satisfactorily and that they are not of serious concern to plant unavailability. On the other hand, non-safety-related equipment which is still vital to plant performances is more frequently responsible for plant outages and losses in electricity production. QA programmes implemented on such equipment are in principle less strict, unsystematic and, in a number of cases, non-existent. An attempt has been made to analyse the existing operating experience data in order to identify the correlation of outage statistics with QA programmes required by existing standards and their implementation practices, both in respect of programme coverage and intensity. Unfortunately, existing operating experience data cannot directly correlate plant performance with the QA programmes implemented in order to demonstrate the effectiveness of QA techniques to plant safety, reliability of plant equipment and plant availability. For these reasons an analysis is made of outage statistics to identify the modes and causes of outages and to relate them to existing QA requirements and practices. Some conclusions are deduced that relate to a possible improvement of plant performance by consequent implementation of QA requirements to the equipment and activities responsible for both plant safety and efficient electricity production, and by adequate grading of QA activities to obtain a cost-effective QA programme in plant operation. (author)

  20. SU-G-TeP4-02: A Method for Evaluating the Direct Impact of Failed IMRT QAs On Patient Dose

    Energy Technology Data Exchange (ETDEWEB)

    Geneser, S; Butkus, M [Yale University School of Medicine/YNHH Radiology, New Haven, CT (United States)

    2016-06-15

    Purpose: We developed a method to calculate patient doses corresponding to IMRT QA measurements in order to determine and assess the actual dose delivered for plans with failed (or borderline) IMRT QA. This work demonstrates the feasibility of automatically computing delivered patient dose from portal dosimetry measurements in the Varian TPS system, which would provide a valuable and clinically viable IMRT QA tool for physicists and physicians. Methods: IMRT QA fluences were measured using portal dosimetry, processed using in-house matlab software, and imported back into Eclipse to calculate dose on the planning CT. To validate the proposed workflow, the Eclipse calculated portal dose for a 5-field sliding window prostate boost plan was processed as described above. The resulting dose was compared to the planned dose and found to be within 0.5 Gy. Two IMRT QA results for the prostate boost plan (one that failed and one that passed) were processed and the resulting patient doses were evaluated. Results: The max dose difference between IMRT QA #1 and the original planned and approved dose is 4.5 Gy, while the difference between the planned and IMRT QA #2 dose is 4.0 Gy. The inferior portion of the PTV is slightly underdosed in both plans, and the superior portion is slightly overdosed. The patient dose resulting from IMRT QA #1 and #2 differs by only 0.5 Gy. With this new information, it may be argued that the evaluated plan alteration to obtain passing gamma analysis produced clinically irrelevant differences. Conclusion: Evaluation of the delivered QA dose on the planning CT provides valuable information about the clinical relevance of failed or borderline IMRT QAs. This particular workflow demonstrates the feasibility of pushing the measured IMRT QA portal dosimetry results directly back onto the patient planning CT within the Varian system.