WorldWideScience

Sample records for pvt lapse count

  1. Neutron counting and gamma spectroscopy with PVT detectors

    International Nuclear Information System (INIS)

    Mitchell, Dean James; Brusseau, Charles A.

    2011-01-01

    Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare 252 Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for 252 Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

  2. Validity and sensitivity of a brief psychomotor vigilance test (PVT-B) to total and partial sleep deprivation

    Science.gov (United States)

    Basner, Mathias; Mollicone, Daniel; Dinges, David F.

    2011-12-01

    The Psychomotor Vigilance Test (PVT) objectively assesses fatigue-related changes in alertness associated with sleep loss, extended wakefulness, circadian misalignment, and time on task. The standard 10-min PVT is often considered impractical in applied contexts. To address this limitation, we developed a modified brief 3-min version of the PVT (PVT-B). The PVT-B was validated in controlled laboratory studies with 74 healthy subjects (34 female, aged 22-45 years) that participated either in a total sleep deprivation (TSD) study involving 33 h awake ( N=31 subjects) or in a partial sleep deprivation (PSD) protocol involving 5 consecutive nights of 4 h time in bed ( N=43 subjects). PVT and PVT-B were performed regularly during wakefulness. Effect sizes of 5 key PVT outcomes were larger for TSD than PSD and larger for PVT than for PVT-B for all outcomes. Effect size was largest for response speed (reciprocal response time) for both the PVT-B and the PVT in both TSD and PSD. According to Cohen's criteria, effect sizes for the PVT-B were still large (TSD) or medium to large (PSD, except for fastest 10% RT). Compared to the 70% decrease in test duration the 22.7% (range 6.9-67.8%) average decrease in effect size was deemed an acceptable trade-off between duration and sensitivity. Overall, PVT-B performance had faster response times, more false starts and fewer lapses than PVT performance (all psleep loss between PVT-B and PVT for all outcome variables (all P>0.15) but the fastest 10% response times during PSD ( P<0.001), and effect sizes increased from 1.38 to 1.49 (TSD) and 0.65 to 0.76 (PSD), respectively. In conclusion, PVT-B tracked standard 10-min PVT performance throughout both TSD and PSD, and yielded medium to large effect sizes. PVT-B may be a useful tool for assessing behavioral alertness in settings where the duration of the 10-min PVT is considered impractical, although further validation in applied settings is needed.

  3. Selective neuronal lapses precede human cognitive lapses following sleep deprivation.

    Science.gov (United States)

    Nir, Yuval; Andrillon, Thomas; Marmelshtein, Amit; Suthana, Nanthia; Cirelli, Chiara; Tononi, Giulio; Fried, Itzhak

    2017-12-01

    Sleep deprivation is a major source of morbidity with widespread health effects, including increased risk of hypertension, diabetes, obesity, heart attack, and stroke. Moreover, sleep deprivation brings about vehicle accidents and medical errors and is therefore an urgent topic of investigation. During sleep deprivation, homeostatic and circadian processes interact to build up sleep pressure, which results in slow behavioral performance (cognitive lapses) typically attributed to attentional thalamic and frontoparietal circuits, but the underlying mechanisms remain unclear. Recently, through study of electroencephalograms (EEGs) in humans and local field potentials (LFPs) in nonhuman primates and rodents it was found that, during sleep deprivation, regional 'sleep-like' slow and theta (slow/theta) waves co-occur with impaired behavioral performance during wakefulness. Here we used intracranial electrodes to record single-neuron activities and LFPs in human neurosurgical patients performing a face/nonface categorization psychomotor vigilance task (PVT) over multiple experimental sessions, including a session after full-night sleep deprivation. We find that, just before cognitive lapses, the selective spiking responses of individual neurons in the medial temporal lobe (MTL) are attenuated, delayed, and lengthened. These 'neuronal lapses' are evident on a trial-by-trial basis when comparing the slowest behavioral PVT reaction times to the fastest. Furthermore, during cognitive lapses, LFPs exhibit a relative local increase in slow/theta activity that is correlated with degraded single-neuron responses and with baseline theta activity. Our results show that cognitive lapses involve local state-dependent changes in neuronal activity already present in the MTL.

  4. PVT Degradation Studies: NMR Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Herman M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-06-06

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. Nuclear magnetic resonance spectroscopy has been used to elucidate the state of water inside the PVT. The deuterium NMR results show that water absorbed by PVT under warm, humid conditions enters several distinct environments, and when the PVT is transferred from incubation to ambient temperature and humidity the water is lost on a time scale of a few hours from these samples. Most of the deuterium NMR peaks can be assigned to bulk liquid water, but almost 35% of the detected signal intensity is contained in a resonance that resembles spectra of water contained in nanometer-scale pores in mesoporous carbon.

  5. PVT Degradation Studies: Acoustic Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-01

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

  6. PVT roadmap. A European guide for the development and market introduction of PVT technology

    International Nuclear Information System (INIS)

    Zondag, H.A.; Van Helden, W.G.J.; Bakker, M.; Affolter, P.; Eisenmann, W.; Fechner, H.; Rommel, M.; Schaap, A.; Soerensen, H.; Tripanagnostopoulos, Y.

    2006-06-01

    The aim of the roadmap is to identify promising markets for PVT (PhotoVoltaic Thermal) technology , and to identify the economical, policy, legislative and technical bottlenecks. In addition, the roadmap wants to inform the parties in the market on PVT. It thereby targets a broad range of professionals, including policy makers, solar manufacturers, installers and researchers. This work has been carried out within the PVT forum project, which is part of the EU-supported project PV-Catapult. The aim of PVT Forum is to lay the foundations for a large-scale introduction of PVT technology in Europe by means of this roadmap. In order to construct the roadmap, a two-step approach was taken. As a first step, PVT experts, PV and solar thermal industries and other stakeholders were brought together in two workshops, connected to the PVSEC 2004 in Paris and the Eurosun conference 2004 in Freiburg, to identify drivers and barriers for PVT. The results of these two workshops, that were presented in two workshop reports, were used as input for the roadmap presented here. As a second step, the PVT roadmap was written, formulating the necessary actions that should be taken on short, medium and long term in order to enlarge the market for PVT products. The chapters of the roadmap are written and reviewed by the various participants in PVT Forum. These participants have been selected for this project on the basis of their contribution to PVT development over the last years

  7. PVT Panels. Fully renewable and competitive

    International Nuclear Information System (INIS)

    Bakker, M.; Strootman, K.J.; Jong, M.J.M.

    2003-10-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. PVT panels generate more solar energy per unit surface area than a combination of separate PV panels and solar thermal collectors, and share the aesthetic advantage of PV. After several years of research, PVT panels have been developed into a product that is now ready for market introduction. One of the most promising system concepts, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS, and has been found to be able to fully cover both the building related electricity and heat consumption, while keeping the long-term average ground temperature constant. The cost and payback time of such a system have been determined; it has been found that the payback time of this system is approximately two-thirds of the payback time of an identical system but with 21 m 2 of PV panels and 4 m 2 of solar thermal collectors. Finally, by looking at the expected growth in the PV and solar thermal collector market, the market potential for for PVT panels has been found to be very large

  8. PVT roadmap. A European guide for the development and market introduction of PVT technology

    International Nuclear Information System (INIS)

    Zondag, H.A.; Van Helden, W.G.J.; Bakker, M.; Affolter, P.; Eisenmann, W.; Fechner, H.; Rommel, M.; Schaap, A.; Soerensen, H.; Tripanagnostopoulos, Y.

    2005-11-01

    In PVT technology, heat is extracted from PV cells. In this way, a device is made that produces both electricity and heat. In the EU-funded co-ordination action PV-Catapult, workshops on PVT were organised at the PVSEC 2004 Conference in Paris and the Eurosun 2004 conference in Freiburg, to obtain active participation of the PV and solar thermal communities. Currently, the results of the workshops are used in the drafting of a roadmap for the large-scale introduction of PVT technology on the market. First results will be presented here

  9. Lapse rate modeling

    DEFF Research Database (Denmark)

    De Giovanni, Domenico

    2010-01-01

    prepayment models for mortgage backed securities, this paper builds a Rational Expectation (RE) model describing the policyholders' behavior in lapsing the contract. A market model with stochastic interest rates is considered, and the pricing is carried out through numerical approximation...

  10. Lapse Rate Modeling

    DEFF Research Database (Denmark)

    De Giovanni, Domenico

    prepayment models for mortgage backed securities, this paper builds a Rational Expectation (RE) model describing the policyholders' behavior in lapsing the contract. A market model with stochastic interest rates is considered, and the pricing is carried out through numerical approximation...

  11. Signal-to-Noise Ratio in PVT Performance as a Cognitive Measure of the Effect of Sleep Deprivation on the Fidelity of Information Processing.

    Science.gov (United States)

    Chavali, Venkata P; Riedy, Samantha M; Van Dongen, Hans P A

    2017-03-01

    There is a long-standing debate about the best way to characterize performance deficits on the psychomotor vigilance test (PVT), a widely used assay of cognitive impairment in human sleep deprivation studies. Here, we address this issue through the theoretical framework of the diffusion model and propose to express PVT performance in terms of signal-to-noise ratio (SNR). From the equations of the diffusion model for one-choice, reaction-time tasks, we derived an expression for a novel SNR metric for PVT performance. We also showed that LSNR-a commonly used log-transformation of SNR-can be reasonably well approximated by a linear function of the mean response speed, LSNRapx. We computed SNR, LSNR, LSNRapx, and number of lapses for 1284 PVT sessions collected from 99 healthy young adults who participated in laboratory studies with 38 hr of total sleep deprivation. All four PVT metrics captured the effects of time awake and time of day on cognitive performance during sleep deprivation. The LSNR had the best psychometric properties, including high sensitivity, high stability, high degree of normality, absence of floor and ceiling effects, and no bias in the meaning of change scores related to absolute baseline performance. The theoretical motivation of SNR and LSNR permits quantitative interpretation of PVT performance as an assay of the fidelity of information processing in cognition. Furthermore, with a conceptual and statistical meaning grounded in information theory and generalizable across scientific fields, LSNR in particular is a useful tool for systems-integrated fatigue risk management. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  12. Performance analysis of photovoltaic thermal (PVT) water collectors

    International Nuclear Information System (INIS)

    Fudholi, Ahmad; Sopian, Kamaruzzaman; Yazdi, Mohammad H.; Ruslan, Mohd Hafidz; Ibrahim, Adnan; Kazem, Hussein A.

    2014-01-01

    Highlights: • Performances analysis of PVT collector based on energy efficiencies. • New absorber designs of PVT collectors were presented. • Comparison present study with other absorber collector designs was presented. • High efficiencies were obtained for spiral flow absorber. - Abstract: The electrical and thermal performances of photovoltaic thermal (PVT) water collectors were determined under 500–800 W/m 2 solar radiation levels. At each solar radiation level, mass flow rates ranging from 0.011 kg/s to 0.041 kg/s were introduced. The PVT collectors were tested with respect to PV efficiency, thermal efficiency, and a combination of both (PVT efficiency). The results show that the spiral flow absorber exhibited the highest performance at a solar radiation level of 800 W/m 2 and mass flow rate of 0.041 kg/s. This absorber produced a PVT efficiency of 68.4%, a PV efficiency of 13.8%, and a thermal efficiency of 54.6%. It also produced a primary-energy saving efficiency ranging from 79% to 91% at a mass flow rate of 0.011–0.041 kg/s

  13. The possibility of developing hybrid PV/T solar system

    Science.gov (United States)

    Dobrnjac, M.; Zivkovic, P.; Babic, V.

    2017-05-01

    An alternative and cost-effective solution to developing integrated PV system is to use hybrid photovoltaic/thermal (PV/T) solar system. The temperature of PV modules increases due to the absorbed solar radiation that is not converted into electricity, causing a decrease in their efficiency. In hybrid PV/T solar systems the reduction of PV module temperature can be combined with a useful fluid heating. In this paper we present the possibility of developing a new hybrid PV/T solar system. Hybrid PV/T system can provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation. We developed PV/T prototype consisted of commercial PV module and thermal panel with our original solution of aluminium absorber with special geometric shapes. The main advantages of our combined PV/T system are: removing of heat from the PV panel; extending the lifetime of photovoltaic cells; excess of the removing heat from PV part is used to heat the fluid in the thermal part of the panel; the possibility of using on the roof and facade constructions because less weight.

  14. Thermal performances of vertical hybrid PV/T air collector

    Science.gov (United States)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  15. A new concept of hybrid photovoltaic thermal (PVT) collector with natural circulation

    Science.gov (United States)

    Lu, Longsheng; Wang, Xiaowu; Wang, Shuai; Liu, Xiaokang

    2017-07-01

    Hybrid photovoltaic thermal (PVT) technology refers to the integration of a photovoltaic module into a conventional solar thermal collector. Generally, the traditional design of a PVT collector has solar cells fixed on the top surface of an absorber in a flat-plate solar thermal collector. In this work, we presented a new concept of water-based PVT collector in which solar cells were directly placed on the bottom surface of its glass cover. A dynamic numerical model of this new PVT is developed and validated by experimental tests. With numerical analysis, it is found that at same covering factor, the electricity conversion efficiency of solar cells of the new PVT exceed that of the traditional PVT by nearly 10% while its thermal efficiency is approximately 30% lower than that of the traditional PVT. When the covering factor changes from 0.05 to 1, the thermal efficiency of the new PVT drops nearly 70%. The thermal efficiency of both the new PVT and the traditional PVT rise up as the water mass in tank increases. Meanwhile, the final water temperature in tank of the traditional PVT collector declines more than 17 °C, whereas that of the new PVT declines less than 6 °C, when the water mass increases from 100 to 300 kg.

  16. A-3 Construction Time Lapse

    Science.gov (United States)

    2009-01-01

    A time lapse from start to finish of steel erection for the 235-foot tall A-3 Test Stand. Ground work for the stand was broken in August 2008 and the final structural steel beam was placed April 9, 2009.

  17. TimeLapseAnalyzer: Multi-target analysis for live-cell imaging and time-lapse microscopy

    DEFF Research Database (Denmark)

    Huth, Johannes; Buchholz, Malte; Kraus, Johann M.

    2011-01-01

    The direct observation of cells over time using time-lapse microscopy can provide deep insights into many important biological processes. Reliable analyses of motility, proliferation, invasive potential or mortality of cells are essential to many studies involving live cell imaging and can aid in...... counting and tube formation analysis in high throughput screening of live-cell experiments. TimeLapseAnalyzer is freely available (MATLAB, Open Source) at http://www.informatik.uniulm. de/ni/mitarbeiter/HKestler/tla......., we developed TimeLapseAnalyzer. Apart from general purpose image enhancements and segmentation procedures, this extensible, self-contained, modular cross-platform package provides dedicated modalities for fast and reliable analysis of multi-target cell tracking, scratch wound healing analysis, cell...

  18. Environmental and exergy benefit of nanofluid-based hybrid PV/T systems

    International Nuclear Information System (INIS)

    Hassani, Samir; Saidur, R.; Mekhilef, Saad; Taylor, Robert A.

    2016-01-01

    Highlights: • Environmental and ExPBT analysis of different PV/T configurations is presented. • The exergy payback time of nanofluid-based hybrid PV/T system is about 2 years. • Nanofluid-based hybrid PV/T system is a reliable solution for pollution prevention. • Nanofluid-based hybrid PV/T system is highly recommended at high solar concentration. - Abstract: Photovoltaic/thermal (PV/T) solar systems, which produce both electrical and thermal energy simultaneously, represent a method to achieve very high conversion rates of sunlight into useful energy. In recent years, nanofluids have been proposed as efficient coolants and optical filter for PV/T systems. Aim of this paper is to theoretically analyze the life cycle exergy of three different configurations of nanofluids-based PV/T hybrid systems, and compare their performance to a standard PV and PV/T system. Electrical and thermal performance of the analyzed solar collectors was investigated numerically. The life cycle exergy analysis revealed that the nanofluids-based PV/T system showed the best performance compared to a standard PV and PV/T systems. At the optimum value of solar concentration C, nanofluid-based PV/T configuration with optimized optical and thermal properties produces ∼1.3 MW h/m 2 of high-grade exergy annually with the lowest exergy payback time of 2 years, whereas these are ∼0.36, ∼0.79 MW h/m 2 and 3.48, 2.55 years for standard PV and PV/T systems, respectively. In addition, the nanofluids-based PV/T system can prevent the emissions of about 448 kg CO 2 eq m −2 yr −1 . Overall, it was found that the nanofluids-based PV/T with optimized optical and thermal properties has potential for further development in a high-concentration solar system.

  19. Investigation of a hybrid PVT air collector system

    Science.gov (United States)

    Haddad, S.; Touafek, K.; Mordjaoui, M.; Khelifa, A.; Tabet, I.

    2017-02-01

    The photovoltaic thermal hybrid (PVT) collectors, which simultaneously produce electricity and heat, are an alternative to photovoltaic modules and thermal collectors installed separately. Indeed, the heat extracted from the solar cell is used to heat water or air, thereby cooling the cell, and thus increasing its energy efficiency. This paper deals with a hybrid PVT air collector in which a new design has been proposed and tested. Its principle is based on the return of the preheating air to a second heating. The air thus passes twice under the solar cells before being evacuated to the outside of the collector (for space heating). The system is modular and expandable to cover large spaces to be heated. The experimental results of this novel design are presented and discussed under both normal and forced circulation. This technique of air return shows favorable results in terms of the quality of the heated air and electric power generation.

  20. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations...... can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations....

  1. Industrial application of PV/T solar energy systems

    International Nuclear Information System (INIS)

    Kalogirou, S.A.; Tripanagnostopoulos, Y.

    2007-01-01

    Hybrid photovoltaic/thermal (PV/T) systems consist of PV modules and heat extraction units mounted together. These systems can simultaneously provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation than plain photovoltaics. Industries show high demand of energy for both heat and electricity and the hybrid PV/T systems could be used in order to meet this requirement. In this paper the application aspects in the industry of PV/T systems with water heat extraction is presented. The systems are analyzed with TRNSYS program for three locations Nicosia, Athens and Madison that are located at different latitudes. The system comprises 300 m 2 of hybrid PV/T collectors producing both electricity and thermal energy and a 10 m 3 water storage tank. The work includes the study of an industrial process heat system operated at two load supply temperatures of 60 deg. C and 80 deg. C. The results show that the electrical production of the system, employing polycrystalline solar cells, is more than the amorphous ones but the solar thermal contribution is slightly lower. A non-hybrid PV system produces about 25% more electrical energy but the present system covers also, depending on the location, a large percentage of the thermal energy requirement of the industry considered. The economic viability of the systems is proven, as positive life cycle savings are obtained in the case of hybrid systems and the savings are increased for higher load temperature applications. Additionally, although amorphous silicon panels are much less efficient than the polycrystalline ones, better economic figures are obtained due to their lower initial cost, i.e., they have better cost/benefit ratio

  2. Isobaric PVT Behavior of Poly(Carbonate) (PC)

    Science.gov (United States)

    Grassia, Luigi; D'Amore, Alberto

    2010-06-01

    The scaling law for relaxation times, τ(V,T) = ℑ(TVγ), recently proposed by Casalini and Roland, is utilized in the framework of KAHR (Kovacs Aklonis Hutchinson and Ramos) phenomenological theory. With this approach it is shown that the Pressure, Volume, Temperature (PVT) data obtained on Poly(carbonate)(PC) can be reliably predicted, in the region of the alpha relaxation, by using only two fitting parameters, namely: the relaxation time in the reference condition, τg, and the fractional exponent, β that describes the dispersion of the alpha relaxation.

  3. Optimal design of orientation of PV/T collector with reflectors

    International Nuclear Information System (INIS)

    Kostic, Lj.T.; Pavlovic, T.M.; Pavlovic, Z.T.

    2010-01-01

    Hybrid conversion of solar radiation implies simultaneous solar radiation conversion into thermal and electrical energy in the PV/Thermal collector. In order to get more thermal and electrical energy, flat solar radiation reflectors have been mounted on PV/T collector. To obtain higher solar radiation intensity on PV/T collector, position of reflectors has been changed and optimal position of reflectors has been determined by both experimental measurements and numerical calculation so as to obtain maximal concentration of solar radiation intensity. The calculated values have been found to be in good agreement with the measured ones, both yielding the optimal position of the flat reflector to be the lowest (5 o ) in December and the highest (38 o ) in June. In this paper, the thermal and electrical efficiency of PV/T collector without reflectors and with reflectors in optimal position have been calculated. Using these results, the total efficiency and energy-saving efficiency of PV/T collector have been determined. Energy-saving efficiency for PV/T collector without reflectors is 60.1%, which is above the conventional solar thermal collector, whereas the energy-saving efficiency for PV/T collector with reflectors in optimal position is 46.7%, which is almost equal to the values for conventional solar thermal collector. Though the energy-saving efficiency of PV/T collector decreases slightly with the solar radiation intensity concentration factor, i.e. the thermal and electrical efficiency of PV/T collector with reflectors are lower than those of PV/T collector without reflectors, the total thermal and electrical energy generated by PV/T collector with reflectors in optimal position are significantly higher than total thermal and electrical energy generated by PV/T collector without reflectors.

  4. Optimization of a PV/T (photovoltaic/thermal) active solar still

    International Nuclear Information System (INIS)

    Saeedi, F.; Sarhaddi, F.; Behzadmehr, A.

    2015-01-01

    In this paper, the optimization of a PV/T (photovoltaic/thermal) active solar still is carried out. Analytical expressions for glass cover temperature, basin temperature, brackish water temperature and fresh water productivity are obtained by writing energy balance for different components of PV/T active solar still. The output electrical power of PV/T active solar still is calculated by four-parameter I–V (current–voltage) model. Objective function in present study is the energy efficiency of PV/T active solar still. A computer simulation program has been developed in order to obtain thermal and electrical parameters, respectively. The simulation results of the present study are in fair agreement with the experimental data of previous literatures. Finally, the optimization of PV/T active solar still has been carried out and the optimized value of mass flow rate, number of PV/T collector and the objective function have been obtained. Furthermore, the effect of various operating parameters on energy efficiency have been investigated. - Highlights: • The comprehensive optimization of a PV/T active solar still is carried out. • Present study is based on numerical simulation. • A modified energy efficiency for PV/T active solar still is obtained. • The effect of design and operating parameters is investigated on energy efficiency

  5. Indoor simulation and testing of photovoltaic thermal (PV/T) air collectors

    NARCIS (Netherlands)

    Solanki, S.C.; Dubey, Swapnil; Tiwari, A.

    2009-01-01

    An indoor standard test procedure has been developed for thermal and electrical testing of PV/T collectors connected in series. For this, a PV/T solar air heater has been designed, fabricated and its performance over different operating parameters were studied. Based on the energy balance equations,

  6. Long non-coding RNA PVT1: Emerging biomarker in digestive system cancer.

    Science.gov (United States)

    Zhou, Dan-Dan; Liu, Xiu-Fen; Lu, Cheng-Wei; Pant, Om Prakash; Liu, Xiao-Dong

    2017-12-01

    The digestive system cancers are leading cause of cancer-related death worldwide, and have high risks of morbidity and mortality. More and more long non-coding RNAs (lncRNAs) have been studied to be abnormally expressed in cancers and play a key role in the process of digestive system tumour progression. Plasmacytoma variant translocation 1 (PVT1) seems fairly novel. Since 1984, PVT1 was identified to be an activator of MYC in mice. Its role in human tumour initiation and progression has long been a subject of interest. The expression of PVT1 is elevated in digestive system cancers and correlates with poor prognosis. In this review, we illustrate the various functions of PVT1 during the different stages in the complex process of digestive system tumours (including oesophageal cancer, gastric cancer, colorectal cancer, hepatocellular carcinoma and pancreatic cancer). The growing evidence shows the involvement of PVT1 in both proliferation and differentiation process in addition to its involvement in epithelial to mesenchymal transition (EMT). These findings lead us to conclude that PVT1 promotes proliferation, survival, invasion, metastasis and drug resistance in digestive system cancer cells. We will also discuss PVT1's potential in diagnosis and treatment target of digestive system cancer. There was a great probability PVT1 could be a novel biomarker in screening tumours, prognosis biomarkers and future targeted therapy to improve the survival rate in cancer patients. © 2017 John Wiley & Sons Ltd.

  7. Radiation-damage measurements on PVT-based plastic scintillators

    International Nuclear Information System (INIS)

    Ilie, S.; Schoenbacher, H.; Tavlet, M.

    1993-01-01

    Samples of PVT-based plastic scintillators produced by Nuclear Enterprise Technology Ltd. (NET) were irradiated up to 9 kGy, both with a gamma source and within a typical accelerator radiation field (CERN PS ACOL Irradiation Facility). The consequent reduction of scintillating efficiency and light transmission were measured, as well as subsequent recovery, over a period of several months. The main results show that irradiation affects more the light transmission than the light emission. The radiation type does not affect either the amount of transmission reduction or the recovery. Observations were also made by means of polarized light. Non-uniformities and internal stresses were observed in scintillator bulks which were polymerized too quickly. These defects influence the light transmission. (orig.)

  8. Thermal conductivity and PVT measurements of pentafluoroethane (refrigerant HFC-125)

    International Nuclear Information System (INIS)

    Tsvetkov, O.B.; Kletski, A.V.; Laptev, Yu.A.

    1995-01-01

    By means of the transient and steady-state coaxial cylinder methods, the thermal conductivity of pentfluoroethane was investigated at temperatures from 187 to 419 K and pressures from atmospheric to 6.0 MPa. The estimated uncertainty of the measured results is ± (2-3)%. The operation of the experimental apparatus was validated by measuring the thermal conductivity of R22 and R12. Determinations of the vapor pressure and PVT properties were carried out by a constant-volume apparatus for the temperature range 263 to 443 K, pressures up to 6 MPa, and densities from 36 to 516 kg m -3 . The uncertainties in temperature, pressure, and density are less than ±10 mK, ±0.08%, and ±0.1%, respectively

  9. The high pressure PVT properties of deuterium oxide

    International Nuclear Information System (INIS)

    Fine, R.A.; Millero, F.J.

    1975-01-01

    The high pressure isothermal compressibilities of deuterium oxide from 5 to 100 degreeC and 0 to 1000 bars applied or gauge pressure were determined from sound speed data. These compressibilities were used to derive an equation of state of the form V 0 P/(V 0 - V/supP/) = B + A 1 P + A 2 P 2 , where V 0 and V/supP/ are the specific volumes at an applied pressure of zero and P; and B, A 1 , and A 2 are polynomial functions of temperature. The compressibilities derived from this equation of state are consistent with those derived from the sound speed data to plus-or-minus0.016times10 -6 bar -1 over the entire pressure and temperature range (this is equivalent to approx.0.2 m sec -1 in sound speed). The 1 atm sound-derived compressibilities agree on the average to plus-or-minus0.06times10 -6 bar -1 with the direct measurements of Millero and Lepple. The P--V--T data from the sound-derived equation are compared with the high pressure work of Bridgman, Kesselman, Juza et al., and Emmet and Millero. Good agreement (average deviation of plus-or-minus28times10 -6 cm 3 g -1 ) was found with the recent specific volume measurements of Emmet and Millero. The P--V--T properties of D 2 O are compared to pure water. D 2 O and H 2 O are shown to follow similar trends. Contrary to previous reports, the D 2 O/H 2 O ratios of the specific volumes and specific heats are shown to be functions of both temperature and pressure

  10. Performance improvement of the finned passive PVT system using reflectors like removable insulation covers

    International Nuclear Information System (INIS)

    Ziapour, Behrooz M.; Palideh, Vahid; Mokhtari, Farhad

    2016-01-01

    Highlights: • A passive PVT system means the combination of a PV panel and a compact solar water heater. • Comparative study was done on performance characteristics in passive and hybrid PVT systems. • Reflectors effects on performance of a finned passive PVT system were numerically studied. • Results show that the finned passive PVT system has higher performance than the hybrid type. • Reflectors reduce the night heat losses and increase the solar radiation rate on PVT system. - Abstract: A passive photovoltaic–thermal system (PVT) is the combination of a photovoltaic (PV) panel and a compact solar water heater for co-generation of heat and electricity. This system bears considerable heat losses to ambient, particularly at noncollection times. One simple way to overcome this problem is to use a removable insulation cover on the collector's outer glazing. In this paper, the effects of the reflectors on day and night performance of a finned passive PVT system were numerically studied. At nonenergy collection time, the reflectors can turn and cover the collector cover glass as a nonconductor material. Simulation results showed that the reflectors reduce the night heat losses and increase the solar radiation rate on the absorber plate. The use of removable insulation reflectors resulted to saving extra sensibly thermal energy. Also, the solar cells power generation (P_s_c), in the case of reflectors installed, was reinforced.

  11. A roadmap for the development and market introduction of PVT technology

    International Nuclear Information System (INIS)

    Zondag, H.A.; Van Helden, W.G.J.; Bakker, M.; Elswijk, M.J.

    2005-11-01

    In PVT technology, heat is extracted from PV cells. In this way, a device is made that produces both electricity and heat. In the EU funded coordination action PV-Catapult, workshops on PVT were organised at the PVSEC 2004 Conference in Paris and the Eurosun 2004 conference in Freiburg, to obtain active participation of the PV and solar thermal communities. Currently, the results of the workshops are used in the drafting of a roadmap for the large scale introduction of PVT technology on the market. First results will be presented here

  12. Mathematical modeling of photovoltaic thermal PV/T system with v-groove collector

    Science.gov (United States)

    Zohri, M.; Fudholi, A.; Ruslan, M. H.; Sopian, K.

    2017-07-01

    The use of v-groove in solar collector has a higher thermal efficiency in references. Dropping the working heat of photovoltaic panel was able to raise the electrical efficiency performance. Electrical and thermal efficiency were produced by photovoltaic thermal (PV/T) system concurrently. Mathematical modeling based on steady-state thermal analysis of PV/T system with v-groove was conducted. With matrix inversion method, the energy balance equations are explained by means of the investigative method. The comparison results show that in the PV/T system with the V-groove collector is higher temperature, thermal and electrical efficiency than other collectors.

  13. Short-term PV/T module temperature prediction based on PCA-RBF neural network

    Science.gov (United States)

    Li, Jiyong; Zhao, Zhendong; Li, Yisheng; Xiao, Jing; Tang, Yunfeng

    2018-02-01

    Aiming at the non-linearity and large inertia of temperature control in PV/T system, short-term temperature prediction of PV/T module is proposed, to make the PV/T system controller run forward according to the short-term forecasting situation to optimize control effect. Based on the analysis of the correlation between PV/T module temperature and meteorological factors, and the temperature of adjacent time series, the principal component analysis (PCA) method is used to pre-process the original input sample data. Combined with the RBF neural network theory, the simulation results show that the PCA method makes the prediction accuracy of the network model higher and the generalization performance stronger than that of the RBF neural network without the main component extraction.

  14. Android App Incorporating the PVT to Deliver Individualized Fatigue Risk Management in Commercial Trucking

    Data.gov (United States)

    National Aeronautics and Space Administration — The overarching objective of this project is to achieve an Android App that incorporates the Psychomotor Vigilance Task (PVT) to deliver Individualized Fatigue Risk...

  15. Expression of hsa_circ_PVT1 in human hepatocellular carcinoma and its clinical significance

    Directory of Open Access Journals (Sweden)

    Yuan-xin ZHU

    2018-03-01

    Full Text Available Objective To determine the expression and clinical significance of circ-PVT1 in human hepatocellular carcinoma (HCC and its effect on HCC cell proliferation. Methods The expressions of circ-PVT1 in hepatocellular carcinoma and the matched tumor-adjacent tissues were detected by RT-qPCR and the relationship between pathological indexes and the expression level was analyzed in 46 patients. The expressions of circ-PVT1 in human normal liver cell line (L02 and hepatocellular carcinoma cell lines (HepG2, SMMC-7721, MHCC-97H, MHCC-97L, HCC-LM3 were detected by RT-qPCR and were compared thereafter. With knocking down the expression of circ-PVT1, si-circPVT1 was transfected into HepG2 and SMMC-7721 cells by using lipofectamine technique in vitro, with the si-NC being taken as negative control. After interfering the expression of circ-PVT1, the effect on the proliferation of hepatocellular carcinoma cells was detected by CCK-8 and EDU experiments and flow cytometry was conducted to observe the effect of circ-PVT1 on cell cycle. Results The expression level of circ-PVT1 was significantly higher in HCC tissues than in adjacent tissues (P<0.01, and its high expression level was significantly correlated with tumor size, TNM stage and differentiation degree. Similarly, in human hepatocellular carcinoma cell lines (HepG2, SMMC-7721, MHCC-97H, MHCC-97L, HCC-LM3, the expression level of circ-PVT1 was also higher than that in human normal liver cell line L02 (P<0.05. Compared with the negative control group, silencing of circ-PVT1 resulted in remarkable reduction in cell proliferation of HepG2 and SMMC-7721. Conclusion circ-PVT1 may act as a potential biomarker for HCC diagnosis and may become a novel proliferation factor. DOI: 10.11855/j.issn.0577-7402.2018.03.06

  16. Design and Research of the Movable Hybrid Photovoltaic-Thermal (PVT System

    Directory of Open Access Journals (Sweden)

    Lian Zhang

    2017-04-01

    Full Text Available In recent years, with the development of photovoltaic system and photo-thermal system technology, hybrid photovoltaic-thermal (PVT technology has been a breakthrough in many aspects. This paper describes the movable hybrid PVT system from the aspects of appearance structure, energy flow, and control circuit. The system is equipped with rolling wheels and the simulated light sources also can be removed so that the system can be used in the outdoor conditions. The movable system is also suitable for the PVT system and its related applications without any external power supply. This system combines two technologies: photovoltaic power generation and photo-thermal utilization. The first part of the power supply is for the systems own output power supply, and the second part is for generating thermal energy. The two separate parts can be controlled and monitored respectively through the control circuits and the touch screens. The experimental results show that the system can generate 691 kWh electric energy and 3047.8 kWh thermal energy each year under normal working conditions. The efficiency of the proposed movable hybrid PVT system is calculated to be approximately 42.82% using the revised equations that are proposed in this paper. Therefore, the movable hybrid PVT system can meet the daily demands of hot water and electricity power in remote areas or islands and other non-grid areas. It also can be used to conduct experiment tests for the PVT system.

  17. Thermal performance of a linear Fresnel reflector solar concentrator PV/T energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, Mohamed R. [State Engineering University of Armenia (Armenia)], E-Mail: Dmoh_elbehary@yahoo.com

    2011-07-01

    This is a report on an investigation of photovoltaic/thermal (PV/T) collectors. Solar energy conversion efficiency was increased by taking advantage of PV/T collectors and low solar concentration technologies, combined into a PV/T system operated at elevated temperature. The main novelty is the coupling of a linear Fresnel mirror reflecting concentrator with a channel PV/T collector. Concentrator PV/T collectors can function at temperatures over 100 degrees celsius, and thus thermal energy can be made to drive processes such as refrigeration, desalination and steam production. Solar system analytical thermal performance gives efficiency values over 60%. Combined electric and thermal (CET) efficiency is high. A combined electric and heat power for the linear fresnel reflector approach that employs high performance CPV technology to produce both electricity and thermal energy at low to medium temperatures is presented. A well-functioning PV/T system can be designed and constructed with low concentration and a total efficiency of nearly 80% can be attained.

  18. Recent advances in flat plate photovoltaic/thermal (PV/T) solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Adnan; Othman, Mohd Yusof; Ruslan, Mohd Hafidz; Mat, Sohif; Sopian, Kamaruzzaman [Solar Energy Research Institute Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

    2011-01-15

    Flat plate photovoltaic/thermal (PV/T) solar collector produces both thermal energy and electricity simultaneously. This paper presents the state-of-the-art on flat plate PV/T collector classification, design and performance evaluation of water, air and combination of water and/or air based. This review also covers the future development of flat plate PV/T solar collector on building integrated photovoltaic (BIPV) and building integrated photovoltaic/thermal (BIPVT) applications. Different designs feature and performance of flat plate PV/T solar collectors have been compared and discussed. Future research and development (R and D) works have been elaborated. The tube and sheet design is the simplest and easiest to be manufactured, even though, the efficiency is 2% lower compared to other types of collectors such as, channel, free flow and two-absorber. It is clear from the review that for both air and water based PV/T solar collectors, the important key factors that influenced the efficiency of the system are the area where the collector covered, the number of passes and the gap between the absorber collector and solar cells. From the literature review, it is obvious that the flat plate PV/T solar collector is an alternative promising system for low-energy applications in residential, industrial and commercial buildings. Other possible areas for the future works of BIPVT are also mentioned. (author)

  19. Nähtamatud lapsed / Margit Tõnson

    Index Scriptorium Estoniae

    Tõnson, Margit, 1978-

    2006-01-01

    UNICEFi palvel valmistasid kaheksa tuntud režissööri kassett-filmi maailma kannatavatest lastest "Kõik nähtamatud lapsed" ("All the Invisible Children") : Prantsusmaa - Itaalia 2005. Film on Sõpruse kino kavas

  20. Outdoor Performance Analysis of a Photovoltaic Thermal (PVT) Collector with Jet Impingement and Compound Parabolic Concentrator (CPC)

    OpenAIRE

    Ahed Hameed Jaaz; Husam Abdulrasool Hasan; Kamaruzzaman Sopian; Abdul Amir H. Kadhum; Tayser Sumer Gaaz; Ahmed A. Al-Amiery

    2017-01-01

    This paper discusses the effect of jet impingement of water on a photovoltaic thermal (PVT) collector and compound parabolic concentrators (CPC) on electrical efficiency, thermal efficiency and power production of a PVT system. A prototype of a PVT solar water collector installed with a jet impingement and CPC has been designed, fabricated and experimentally investigated. The efficiency of the system can be improved by using jet impingement of water to decrease the temperature of the solar ce...

  1. Design, Simulation and Experimental Investigation of a Solar System Based on PV Panels and PVT Collectors

    Directory of Open Access Journals (Sweden)

    Annamaria Buonomano

    2016-06-01

    Full Text Available This paper presents numerical and experimental analyses aimed at evaluating the technical and economic feasibility of photovoltaic/thermal (PVT collectors. An experimental setup was purposely designed and constructed in order to compare the electrical performance of a PVT solar field with the one achieved by an identical solar field consisting of conventional photovoltaic (PV panels. The experimental analysis also aims at evaluating the potential advantages of PVT vs. PV in terms of enhancement of electrical efficiency and thermal energy production. The installed experimental set-up includes four flat polycrystalline silicon PV panels and four flat unglazed polycrystalline silicon PVT collectors. The total electrical power and area of the solar field are 2 kWe and 13 m2, respectively. The experimental set-up is currently installed at the company AV Project Ltd., located in Avellino (Italy. This study also analyzes the system from a numerical point of view, including a thermo-economic dynamic simulation model for the design and the assessment of energy performance and economic profitability of the solar systems consisting of glazed PVT and PV collectors. The experimental setup was modelled and partly simulated in TRNSYS environment. The simulation model was useful to analyze efficiencies and temperatures reached by such solar technologies, by taking into account the reference technology of PVTs (consisting of glazed collectors as well as to compare the numerical data obtained by dynamic simulations with the gathered experimental results for the PV technology. The numerical analysis shows that the PVT global efficiency is about 26%. Conversely, from the experimental point of view, the average thermal efficiency of PVT collectors is around 13% and the electrical efficiencies of both technologies are almost coincident and equal to 15%.

  2. Artificial Neural Network based control for PV/T panel to track optimum thermal and electrical power

    International Nuclear Information System (INIS)

    Ben Ammar, Majed; Chaabene, Maher; Chtourou, Zied

    2013-01-01

    Highlights: ► We establish a state model of PV/T panel. ► We study the effect of mass flow rate on PV/T efficiency. ► A real time PV/T control algorithm is proposed. ► A model based optimal thermal and electrical power operation point is tracked. - Abstract: As solar energy is intermittent, many algorithms and electronics have been developed to track the maximum power generation from photovoltaic and thermal panels. Following technological advances, these panels are gathered into one unit: PV/T system. PV/T delivers simultaneously two kinds of power: electrical power and thermal power. Nevertheless, no control systems have been developed in order to track maximum power generation from PV/T system. This paper suggests a PV/T control algorithm based on Artificial Neural Network (ANN) to detect the optimal power operating point (OPOP) by considering PV/T model behavior. The OPOP computes the optimum mass flow rate of PV/T for a considered irradiation and ambient temperature. Simulation results demonstrate great concordance between OPOP model based calculation and ANN outputs.

  3. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  4. The Experimental Performance of an Unglazed PVT Collector with Two Different Absorber Types

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal collectors combine photovoltaic modules and solar thermal collectors, forming a single device that produces electricity and heat simultaneously. There are two types of liquid-type PVT collectors, depending on the existence or absence of a glass cover over the PV module. The glass-covered (glazed PVT collector produces relatively more thermal energy but has a lower electrical yield, whereas the uncovered (unglazed PVT collector has a relatively low thermal energy and somewhat higher electrical performance. The thermal and electrical performance of liquid-type PVT collectors is related not only to the collector design, such as whether a glass cover is used, but also to the absorber design, that is, whether the absorber is for the sheet-and-tube type or the fully wetted type. The design of the absorber, as it comes into contact with the PV modules and the liquid tubes, is regarded as important, as it is related to the heat transfer from the PV modules to the liquid in the tubes. In this paper, the experimental performance of two liquid-type PVT collectors, a sheet-and-tube type and a fully wetted type, was analyzed.

  5. Photovoltaic-thermal (PV/T) solar collectors: Features and performance modelling

    International Nuclear Information System (INIS)

    Atienza-Márquez, Antonio; Bruno, Joan Carles; Coronas, Alberto; Korolija, Ivan; Greenough, Richard; Wright, Andy

    2017-01-01

    Currently, the electrical efficiency of photovoltaic (PV) solar cells ranges between 5–25%. One of the most important parameters that affects the electrical efficiency of a PV collector is the temperature of its cells: the higher temperature, the lower is the efficiency. Photovoltaic/thermal (PV/T) technology is a potential solution to ensure an acceptable solar energy conversion. The PV/T technology produces both electrical and thermal energy simultaneously. It is suitable for low temperature applications (25–40 o C) and overall efficiency increases compared to individual collectors. This paper describes an installation in a single-family house where PV/T collectors are coupled with a ground heat exchanger and a heat pump for domestic hot water and space heating purposes. The aim of this work is twofold. First, the features of the PV/T technology are analyzed. Second, a model of a flat-plate PV/T water collector was developed in TRNSYS in order to analyze collectors performance. (author)

  6. Theoretical investigation of the energy performance of a novel MPCM (Microencapsulated Phase Change Material) slurry based PV/T module

    International Nuclear Information System (INIS)

    Qiu, Zhongzhu; Zhao, Xudong; Li, Peng; Zhang, Xingxing; Ali, Samira; Tan, Junyi

    2015-01-01

    Aim of the paper is to present a theoretical investigation into the energy performance of a novel PV/T module that employs the MPCM (Micro-encapsulated Phase Change Material) slurry as the working fluid. This involved (1) development of a dedicated mathematical model and computer program; (2) validation of the model by using the published data; (3) prediction of the energy performance of the MPCM (Microencapsulated Phase Change Material) slurry based PV/T module; and (4) investigation of the impacts of the slurry flow state, concentration ratio, Reynolds number and slurry serpentine size onto the energy performance of the PV/T module. It was found that the established model, based on the Hottel–Whillier assumption, is able to predict the energy performance of the MPCM slurry based PV/T system at a very good accuracy, with 0.3–0.4% difference compared to a validated model. Analyses of the simulation results indicated that laminar flow is not a favorite flow state in terms of the energy efficiency of the PV/T module. Instead, turbulent flow is a desired flow state that has potential to enhance the energy performance of PV/T module. Under the turbulent flow condition, increasing the slurry concentration ratio led to the reduced PV cells' temperature and increased thermal, electrical and overall efficiency of the PV/T module, as well as increased flow resistance. As a result, the net efficiency of the PV/T module reached the peak level at the concentration ratio of 5% at a specified Reynolds number of 3,350. Remaining all other parameters fixed, increasing the diameter of the serpentine piping led to the increased slurry mass flow rate, decreased PV cells' temperature and consequently, increased thermal, electrical, overall and net efficiencies of the PV/T module. In overall, the MPCM slurry based PV/T module is a new, highly efficient solar thermal and power configuration, which has potential to help reduce fossil fuel consumption and carbon emission to

  7. The lncRNA PVT1 Contributes to the Cervical Cancer Phenotype and Associates with Poor Patient Prognosis.

    Directory of Open Access Journals (Sweden)

    Marissa Iden

    Full Text Available The plasmacytoma variant translocation 1 gene (PVT1 is an lncRNA that has been designated as an oncogene due to its contribution to the phenotype of multiple cancers. Although the mechanism by which PVT1 influences disease processes has been studied in multiple cancer types, its role in cervical tumorigenesis remains unknown. Thus, the present study was designed to investigate the role of PVT1 in cervical cancer in vitro and in vivo. PVT1 expression was measured by quantitative PCR (qPCR in 121 invasive cervical carcinoma (ICC samples, 30 normal cervix samples, and cervical cell lines. Functional assays were carried out using both siRNA and LNA-mediated knockdown to examine PVT1's effects on cervical cancer cell proliferation, migration and invasion, apoptosis, and cisplatin resistance. Our results demonstrate that PVT1 expression is significantly increased in ICC tissue versus normal cervix and that higher expression of PVT1 correlates with poorer overall survival. In cervical cancer cell lines, PVT1 knockdown resulted in significantly decreased cell proliferation, migration and invasion, while apoptosis and cisplatin cytotoxicity were significantly increased in these cells. Finally, we show that PVT1 expression is augmented in response to hypoxia and immune response stimulation and that this lncRNA associates with the multifunctional and stress-responsive protein, Nucleolin. Collectively, our results provide strong evidence for an oncogenic role of PVT1 in cervical cancer and lend insight into potential mechanisms by which PVT1 overexpression helps drive cervical carcinogenesis.

  8. A Review on Photovoltaic-Thermal (PV-T) Air and Water Collectors

    International Nuclear Information System (INIS)

    Avezov, R.R.; Akhatov, J. S.; Avezova, N. R.

    2011-01-01

    This paper presents the state-of-the-art on photovoltaic-thermal PV-T collectors. There are presented two main classification groups: -Air and -Water PV-Thermal collectors, design and performance evaluation, comparison of the findings obtained by various researchers. The review also covers the description of different designs of air and water PV-T collectors, the results of theoretical and experimental works, focused to optimization of the technical and economical performances in terms of electrical as well as thermal outputs. (authors)

  9. General Approach to Characterize Reservoir Fluids Using a Large PVT Database

    DEFF Research Database (Denmark)

    Varzandeh, Farhad; Yan, Wei; Stenby, Erling Halfdan

    2016-01-01

    methods. We proposed a general approach to develop correlations for model parameters and applied it to the characterization for the PC-SAFT EoS. The approach consists in first developing the correlations based on the DIPPR database, and then adjusting the correlations based on a large PVT database......, the approach gives better PVT calculation results for the tested systems. Comparison was also made between PC-SAFT with the proposed characterization method and other EoS models. The proposed approach can be applied to other EoS models for improving their fluid characterization. Besides, the challenges...

  10. COMBINED UNCOVERED SHEET-AND-TUBE PVT-COLLECTOR SYSTEM WITH BUILT-IN STORAGE WATER HEATER

    Directory of Open Access Journals (Sweden)

    Muhammad Abid

    2012-02-01

    Full Text Available This work describes the design and investigation of a simple combined uncovered sheet-and-tube photo-voltaic-thermal (PVT collector system. The PVT-collector system consists of a support, standard PV module (1.22x0.305m, area=0.37m2, fill factor=0.75, sheet-and-tube water collector and storage tank-heater. The collector was fixed under PV module. Inclination angle of the PVT-collector to the horizontal plane was 45 degree. The storage tank-heater played double role i.e. for storage of hot water and for water heating. The PVT-collector system could work in the fixed and tracking modes of operation. During investigations of PVT-collector in natural conditions, solar irradiance, voltage and current of PV module, ambient temperature and water temperature in storage tank were measured. Average thermal and electrical powers of the PVT-collector system at the tracking mode of operation observed were 39W and 21W, with efficiencies of 15% and 8% respectively at the input power of 260W. The maximum temperature of the water obtained was 42oC. The system was observed efficient for low-temperature applications. The PVT-collector system may be used as a prototype for design of PVT-collector system for domestic application, teaching aid and for demonstration purposes.

  11. 77 FR 65886 - Century Metal Recycling PVT. LTD v. Dacon Logistics, LLC dba CODA Forwarding, Great American...

    Science.gov (United States)

    2012-10-31

    ... FEDERAL MARITIME COMMISSION [Docket No. 12-09] Century Metal Recycling PVT. LTD v. Dacon Logistics, LLC dba CODA Forwarding, Great American Alliance Insurance Company, Avalon Risk Management, HAPAG... Recycling Pvt. Ltd d/ b/a/CMR American, LLC (Century Metal), hereinafter ``Complainant,'' against Dacon...

  12. Power-law-lapse time gauges

    International Nuclear Information System (INIS)

    Jantzen, R.T.

    1988-01-01

    The choice of time function for cosmological solutions of gravitational field equations is related to the action of the group of independent scale transformations of the unit of length along orthogonal spatial directions. This is accomplished by the introduction of lapse functions which depend explicitly on the spatial metric in an appropriately defined power-law fashion. The resulting power-law-lapse time gauges are the key to producing nearly all exact solutions of the class of models for which the field equations reduce to ordinary differential equations

  13. Analysis of concentrating PV-T systems for the commercial/industrial sector. Volume III. Technical issues and design guidance

    Energy Technology Data Exchange (ETDEWEB)

    Schwinkendorf, W.E.

    1984-09-01

    This report provide appropriate guidance for addressing the major technical issues associated with the design and installation of a photovoltaic-thermal (PV-T) system. Nomographs are presented for developing preliminary sizing and costing, and issues associated with specific components and the overall design of the electrical and mechanical system are discussed. SAND82-7157/2 presents a review of current PV-T technology and operating systems and a study of potential PV-T applications. Detailed PV-T system designs for three selected applications and the results of a trade-off study for these applications are presented in SAND82-7157/4. A summary of the major results of this entire study and conclusions concerning PV-T systems and applications is presented in SAND82-7157/1.

  14. PC-PVT 2.0: An updated platform for psychomotor vigilance task testing, analysis, prediction, and visualization.

    Science.gov (United States)

    Reifman, Jaques; Kumar, Kamal; Khitrov, Maxim Y; Liu, Jianbo; Ramakrishnan, Sridhar

    2018-07-01

    The psychomotor vigilance task (PVT) has been widely used to assess the effects of sleep deprivation on human neurobehavioral performance. To facilitate research in this field, we previously developed the PC-PVT, a freely available software system analogous to the "gold-standard" PVT-192 that, in addition to allowing for simple visual reaction time (RT) tests, also allows for near real-time PVT analysis, prediction, and visualization in a personal computer (PC). Here we present the PC-PVT 2.0 for Windows 10 operating system, which has the capability to couple PVT tests of a study protocol with the study's sleep/wake and caffeine schedules, and make real-time individualized predictions of PVT performance for such schedules. We characterized the accuracy and precision of the software in measuring RT, using 44 distinct combinations of PC hardware system configurations. We found that 15 system configurations measured RTs with an average delay of less than 10 ms, an error comparable to that of the PVT-192. To achieve such small delays, the system configuration should always use a gaming mouse as the means to respond to visual stimuli. We recommend using a discrete graphical processing unit for desktop PCs and an external monitor for laptop PCs. This update integrates a study's sleep/wake and caffeine schedules with the testing software, facilitating testing and outcome visualization, and provides near-real-time individualized PVT predictions for any sleep-loss condition considering caffeine effects. The software, with its enhanced PVT analysis, visualization, and prediction capabilities, can be freely downloaded from https://pcpvt.bhsai.org. Published by Elsevier B.V.

  15. Lapse varajastest sotsialiseerumisvõimalustest / Inna Järva

    Index Scriptorium Estoniae

    Järva, Inna

    1998-01-01

    Suhtlemine oma ema või täiskasvanutega on lapse üldise psüühilise arengu tähtsaim faktor. Ema ja lapse suhted sotsiaalsete teooriate valguses, lapse varajased sotsialiseerumise võimalused väikelaste mängukoolide kaudu (Ave Kumpase väikelapse mängukool)

  16. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  17. The Development of Monitoring and Control System of the Low PV/T Solar System

    OpenAIRE

    Okhorzina Alena; Bikbulatov Alexander; Yurchenko Alexey; Bernhard Norbert; Aldoshina Oksana

    2016-01-01

    The article presents an autonomous PV/T solar installation. Installing converts solar energy into electricity and heat. The description of its components and elements that enhance its effectiveness shows. The description of the control program and control of the installation is given. The control system provides for tracking the sun and cooling the photovoltaic module.

  18. Calibration of a plastic detector PVT of large dimensions for the detection gamma radiation

    International Nuclear Information System (INIS)

    Armenteros Carmona, J. C.; Suarez navarro, M. J.; Gonzalez-gonzalez, J. A.; Pujol, L.

    2011-01-01

    This article describes the development work on the porch Rad Sentry Canberra brand that uses 2 plastic scintillation detectors PVT large (172 x 32 x 4 cm). In this paper we present the different calibration necessary for the proper functioning of equipment: channel-energy calibration, energy resolution, and efficiency-energy.

  19. Evaluating the thermal and electrical performance of several uncovered PVT collectors with a field test

    NARCIS (Netherlands)

    de Keizer, C.; de Jong, M.; Mendes, T.; Katiyar, M.; Folkerts, W.; Rindt, C.C.M.; Zondag, H.A.

    Recently, there has been a lot of interest in PV thermal systems, which generate both heat and power. Within the WenSDak project, several companies and research institutes work together to (further) develop several uncovered PVT collectors. The outdoor performance of prototypes of these collectors

  20. PVT: an efficient computational procedure to speed up next-generation sequence analysis.

    Science.gov (United States)

    Maji, Ranjan Kumar; Sarkar, Arijita; Khatua, Sunirmal; Dasgupta, Subhasis; Ghosh, Zhumur

    2014-06-04

    High-throughput Next-Generation Sequencing (NGS) techniques are advancing genomics and molecular biology research. This technology generates substantially large data which puts up a major challenge to the scientists for an efficient, cost and time effective solution to analyse such data. Further, for the different types of NGS data, there are certain common challenging steps involved in analysing those data. Spliced alignment is one such fundamental step in NGS data analysis which is extremely computational intensive as well as time consuming. There exists serious problem even with the most widely used spliced alignment tools. TopHat is one such widely used spliced alignment tools which although supports multithreading, does not efficiently utilize computational resources in terms of CPU utilization and memory. Here we have introduced PVT (Pipelined Version of TopHat) where we take up a modular approach by breaking TopHat's serial execution into a pipeline of multiple stages, thereby increasing the degree of parallelization and computational resource utilization. Thus we address the discrepancies in TopHat so as to analyze large NGS data efficiently. We analysed the SRA dataset (SRX026839 and SRX026838) consisting of single end reads and SRA data SRR1027730 consisting of paired-end reads. We used TopHat v2.0.8 to analyse these datasets and noted the CPU usage, memory footprint and execution time during spliced alignment. With this basic information, we designed PVT, a pipelined version of TopHat that removes the redundant computational steps during 'spliced alignment' and breaks the job into a pipeline of multiple stages (each comprising of different step(s)) to improve its resource utilization, thus reducing the execution time. PVT provides an improvement over TopHat for spliced alignment of NGS data analysis. PVT thus resulted in the reduction of the execution time to ~23% for the single end read dataset. Further, PVT designed for paired end reads showed an

  1. Predicting the Initial Lapse Using a Mobile Health Application after Alcohol Detoxification

    Science.gov (United States)

    Chih, Ming-Yuan

    2013-01-01

    The prediction and prevention of the initial lapse--which is defined as the first lapse after a period of abstinence--is important because the initial lapse often leads to subsequent lapses (within the same lapse episode) or relapse. The prediction of the initial lapse may allow preemptive intervention to be possible. This dissertation reports on…

  2. Mercury-free PVT apparatus for thermophysical property analyses of hydrocarbon reservoir fluids

    Energy Technology Data Exchange (ETDEWEB)

    Lansangan, R.M.; Lievois, J.S.

    1992-08-31

    Typical reservoir fluid analyses of complex, multicomponent hydrocarbon mixtures include the volumetric properties, isothermal compressibility, thermal expansivity, equilibrium ratios, saturation pressure, viscosities, etc. These parameters are collectively referred to as PVT properties, an acronym for the primary state variables; pressure, volume, and temperature. The reservoir engineer incorporates this information together with the porous media description in performing material balance calculations. These calculations lead to the determination (estimation) of the initial hydrocarbon in-place, the future reservoir performance, the optimal production scheme, and the ultimate hydrocarbon recovery. About four years ago, Ruska Instrument Corporation embarked on a project to develop an apparatus designed to measure PVT properties that operates free of mercury. The result of this endeavor is the 2370 Hg-Free PVT system which has been in the market for the last three years. The 2370 has evolved from the prototype unit to its present configuration which is described briefly in this report. The 2370 system, although developed as a system-engineered apparatus based on existing technology, has not been exempt from this burden-of-proof Namely, the performance of the apparatus under routine test conditions with real reservoir fluids. This report summarizes the results of the performance and applications testing of the 2370 Hg-Free PVT system. Density measurements were conducted on a pure fluid. The results were compared against literature values and the prediction of an equation of state. Routine reservoir fluid analyses were conducted with a black oil and a retrograde condensate gas mixtures. Limited comparison of the results were performed based on the same tests performed on a conventional mercury-based PVT apparatus. The results of these tests are included in this report.

  3. Amplification of PVT1 contributes to the pathophysiology ofovarian and breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guan, Yinghui; Kuo, Wen-Lin; Stilwell, Jackie; Takano, Hirokuni; Lapuk, Anna; Fridlyand, Jane; Mao, Jian-Hua; Yu, Mami; Ginzinger, David; Gray, Joe W.

    2007-10-09

    Purpose. This study was designed to elucidate the role of amplification at 8q24 in the pathophysiology of ovarian and breast cancer since increased copy number at this locus is one of the most frequent genomic abnormalities in these cancers. Experimental Design. To accomplish this, we assessed the association of amplification at 8q24 with outcome in ovarian cancers using FISH to tissue microarrays and measured responses of ovarian and breast cancer cell lines to specific small interfering RNAs (siRNA) against the oncogene, MYC, and a putative noncoding RNA, PVT1, both of which map to 8q24. Results. Amplification of 8q24 was associated with significantly reduced survival duration. In addition, siRNA-mediated reduction in either PVT1 or MYC expression inhibited proliferation in breast and ovarian cancer cell lines in which they were both amplified and over expressed but not in lines in which they were not amplified/over expressed. Inhibition of PVT1 expression also induced a strong apoptotic response in cell lines in which it was over expressed but not in lines in which it was not amplified/over expressed. Inhibition of MYC, on the other hand, did not induce an apoptotic response in cell lines in which MYC was amplified and over expressed. Conclusions. These results suggest that MYC and PVT1 contribute independently to ovarian and breast pathogenesis when over expressed because of genomic abnormalities. They also suggest that PVT1 mediated inhibition of apoptosis may explain why amplification of 8q24 is associated with reduced survival duration in patients treated with agents that act through apoptotic mechanisms.

  4. Numerical investigation of the thermal and electrical performances for combined solar photovoltaic/thermal (PV/T) modules based on internally extruded fin flow channel

    Science.gov (United States)

    Deng, Y. C.; Li, Q. P.; Wang, G. J.

    2017-11-01

    A solar photovoltaic/thermal (PV/T) module based on internally extruded fin flow channel was investigated numerically in this paper. First of all, the structures of the thin plate heat exchanger and the PV/T module were presented. Then, a numerical model of the PV/T module considering solar irradiation, fluid flow and heat transfer was developed to analyze the performance of the module. Finally, the steady electrical and thermal efficiencies of the PV/T module at different inlet water temperatures and mass flow rates were achieved. These numerical results supply theory basis for practical application of the PV/T module.

  5. Impaired sustained attention and lapses are present in patients with mild obstructive sleep apnea.

    Science.gov (United States)

    Luz, Gabriela Pontes; Guimarães, Thais Moura; Weaver, Terri E; Nery, Luiz E; E Silva, Luciana Oliveira; Badke, Luciana; Coelho, Glaury; Millani-Carneiro, Aline; Tufik, Sergio; Bittencourt, Lia

    2016-05-01

    Severe obstructive sleep apnea (OSA) directly affects the quality of life, mood, and sustained attention of individuals, but it has not yet been established in the literature, if these changes also affect patients with mild OSA. The purpose of this study was to investigate such negative effects on the parameters described above. A controlled study was held at the Universidade Federal de Sao Paulo, Department of Psychobiology. Thirty-nine mild OSA patients and 25 controls were included. Volunteers could be of both genders with body mass index (BMI) ≤35 kg/m(2) and age between 18 and 65 years. Both groups were subjected to full-night polysomnography (PSG), the subjective assessment of mood (Beck Inventory of Anxiety and Depression), Functional Outcomes of Sleep Questionnaire (FOSQ), and the psychomotor vigilance task (PVT) five times during the day. We considered mild OSA patients those with apnea-hypopnea index (AHI) score between 5 and 15. The control group included subjects with AHI scores attention lapses compared with normal subjects.

  6. Design and dynamic simulation of a novel solar trigeneration system based on hybrid photovoltaic/thermal collectors (PVT)

    International Nuclear Information System (INIS)

    Calise, Francesco; D’Accadia, Massimo Dentice; Vanoli, Laura

    2012-01-01

    Highlights: ► Sheet and tube photovoltaic/thermal (PVT) solar collector are investigated. ► PVT is integrated in a novel solar trigeneration system. ► The trigeneration system is dynamically investigated for a mediterranean climate. ► PVT performance is excellent during the summer. ► During the winter PVT thermal energy significantly decreases. - Abstract: In this paper, a Solar Heating and Cooling (SHC) system including photovoltaic/thermal (PVT) collectors is considered, implementing a novel polygeneration system producing electricity, space heating and cooling and domestic hot water. In particular, PVT collectors operating up to 80 °C are considered. A case study for a university building located in Naples (Italy) is developed and discussed. The system is mainly composed by: PVT collectors, a single-stage LiBr–H 2 O absorption chiller, storage tanks and auxiliary heaters. The system also includes additional balance-of-plant devices: heat exchangers, pumps, controllers, cooling tower, etc. The PVT produces electricity which is utilized in part by the building lights and equipments and in part by the system parasitic loads; the rest is eventually sold to the grid. Simultaneously, the PVT system provides the heat required to drive the absorption chiller. The system performance is analyzed from both energetic and economic points of view by means of a zero-dimensional transient simulation model, developed with TRNSYS. The economic results show that the system under investigation can be profitable, provided that an appropriate funding policy is available. In addition, the overall energetic and economic results are comparable to those reported in literature for similar systems.

  7. Predictors of smoking lapse in a human laboratory paradigm.

    Science.gov (United States)

    Roche, Daniel J O; Bujarski, Spencer; Moallem, Nathasha R; Guzman, Iris; Shapiro, Jenessa R; Ray, Lara A

    2014-07-01

    During a smoking quit attempt, a single smoking lapse is highly predictive of future relapse. While several risk factors for a smoking lapse have been identified during clinical trials, a laboratory model of lapse was until recently unavailable and, therefore, it is unclear whether these characteristics also convey risk for lapse in a laboratory environment. The primary study goal was to examine whether real-world risk factors of lapse are also predictive of smoking behavior in a laboratory model of smoking lapse. After overnight abstinence, 77 smokers completed the McKee smoking lapse task, in which they were presented with the choice of smoking or delaying in exchange for monetary reinforcement. Primary outcome measures were the latency to initiate smoking behavior and the number of cigarettes smoked during the lapse. Several baseline measures of smoking behavior, mood, and individual traits were examined as predictive factors. Craving to relieve the discomfort of withdrawal, withdrawal severity, and tension level were negatively predictive of latency to smoke. In contrast, average number of cigarettes smoked per day, withdrawal severity, level of nicotine dependence, craving for the positive effects of smoking, and craving to relieve the discomfort of withdrawal were positively predictive of number of cigarettes smoked. The results suggest that real-world risk factors for smoking lapse are also predictive of smoking behavior in a laboratory model of lapse. Future studies using the McKee lapse task should account for between subject differences in the unique factors that independently predict each outcome measure.

  8. Time-Lapse Measurement of Wellbore Integrity

    Science.gov (United States)

    Duguid, A.

    2017-12-01

    Well integrity is becoming more important as wells are used longer or repurposed. For CO2, shale gas, and other projects it has become apparent that wells represent the most likely unintended migration pathway for fluids out of the reservoir. Comprehensive logging programs have been employed to determine the condition of legacy wells in North America. These studies provide examples of assessment technologies. Logging programs have included pulsed neutron logging, ultrasonic well mapping, and cement bond logging. While these studies provide examples of what can be measured, they have only conducted a single round of logging and cannot show if the well has changed over time. Recent experience with time-lapse logging of three monitoring wells at a US Department of Energy sponsored CO2 project has shown the full value of similar tools. Time-lapse logging has shown that well integrity changes over time can be identified. It has also shown that the inclusion of and location of monitoring technologies in the well and the choice of construction materials must be carefully considered. Two of the wells were approximately eight years old at the time of study; they were constructed with steel and fiberglass casing sections and had lines on the outside of the casing running to the surface. The third well was 68 years old when it was studied and was originally constructed as a production well. Repeat logs were collected six or eight years after initial logging. Time-lapse logging showed the evolution of the wells. The results identified locations where cement degraded over time and locations that showed little change. The ultrasonic well maps show clearly that the lines used to connect the monitoring technology to the surface are visible and have a local effect on cement isolation. Testing and sampling was conducted along with logging. It provided insight into changes identified in the time-lapse log results. Point permeability testing was used to provide an in-situ point

  9. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  10. Performance of Polycrystalline Photovoltaic and Thermal Collector (PVT on Serpentine-Parallel Absorbers Design

    Directory of Open Access Journals (Sweden)

    Mustofa Mustofa

    2017-03-01

    Full Text Available This paper presents the performance of an unglazed polycrystalline photovoltaic-thermal PVT on 0.045 kg/s mass flow rate. PVT combine photovoltaic modules and solar thermal collectors, forming a single device that receive solar radiation and produces heat and electricity simultaneously. The collector figures out serpentine-parallel tubes that can prolong fluid heat conductivity from morning till afternoon. During testing, cell PV, inlet and outlet fluid temperaturs were recorded by thermocouple digital LM35 Arduino Mega 2560. Panel voltage and electric current were also noted in which they were connected to computer and presented each second data recorded. But, in this performance only shows in the certain significant time data. This because the electric current was only noted by multimeter device not the digital one. Based on these testing data, average cell efficieny was about 19%, while thermal efficiency of above 50% and correspondeng cell efficiency of 11%, respectively

  11. Performance of Polycrystalline Photovoltaic and Thermal Collector (PVT on Serpentine-Parallel Absor

    Directory of Open Access Journals (Sweden)

    Mustofa

    2015-10-01

    Full Text Available This paper presents the performance of an unglazed polycrystalline photovoltaic-thermal PVT on 0.045 kg/s mass flow rate. PVT combine photovoltaic modules and solar thermal collectors, forming a single device that receive solar radiation and produces heat and electricity simultaneously. The collector figures out serpentine-parallel tubes that can prolong fluid heat conductivity from morning till afternoon. During testing, cell PV, inlet and outlet fluid temperatures were recorded by thermocouple digital LM35 Arduino Mega 2560. Panel voltage and electric current were also noted in which they were connected to computer and presented each second data recorded. But, in this performance only shows in the certain significant time data. This because the electric current was only noted by multimeter device not the digital one. Based on these testing data, average cell efficiency was about 19%, while thermal efficiency of above 50% and correspondent cell efficiency of 11%, respectively.

  12. Double-pass photovoltaic / thermal (PV/T) solar collector with advanced heat transfer features

    International Nuclear Information System (INIS)

    Mohd Nazari Abu Bakar; Baharudin Yatim; Mohd Yusof Othman; Kamaruzzaman Sopian

    2006-01-01

    The use of PV/T in combination with concentrating reflectors has a potential to significantly increase power production from a given solar cell area. A prototype double-pass photovoltaic-thermal solar air collector with CPR and fins has been designed and fabricated and its performance over a range of operating conditions was studied. The absorber of the hybrid photovoltaic / thermal (PV/T) collector under investigation consists of an array of solar cells for generating electricity, compound parabolic concentrator (CPR) to increase the radiation intensity falling on the solar cells and fins attached to the back side of the absorber plate to improve heat transfer to the flowing air. The thermal, electrical and combined electrical and thermal efficiencies of the collector are presented and discussed

  13. Optimization Design Method and Experimental Validation of a Solar PVT Cogeneration System Based on Building Energy Demand

    Directory of Open Access Journals (Sweden)

    Chao Zhou

    2017-08-01

    Full Text Available Photovoltaic-thermal (PVT technology refers to the integration of a photovoltaic (PV and a conventional solar thermal collector, representing the deep exploitation and utilization of solar energy. In this paper, we evaluate the performance of a solar PVT cogeneration system based on specific building energy demand using theoretical modeling and experimental study. Through calculation and simulation, the dynamic heating load and electricity load is obtained as the basis of the system design. An analytical expression for the connection of PVT collector array is derived by using basic energy balance equations and thermal models. Based on analytical results, an optimized design method was carried out for the system. In addition, the fuzzy control method of frequency conversion circulating water pumps and pipeline switching by electromagnetic valves is introduced in this paper to maintain the system at an optimal working point. Meanwhile, an experimental setup is established, which includes 36 PVT collectors with every 6 PVT collectors connected in series. The thermal energy generation, thermal efficiency, power generation and photovoltaic efficiency have been given in this paper. The results demonstrate that the demonstration solar PVT cogeneration system can meet the building energy demand in the daytime in the heating season.

  14. Life cycle cost analysis of single slope hybrid (PV/T) active solar still

    International Nuclear Information System (INIS)

    Kumar, Shiv; Tiwari, G.N.

    2009-01-01

    This paper presents the life cycle cost analysis of the single slope passive and hybrid photovoltaic (PV/T) active solar stills, based on the annual performance at 0.05 m water depth. Effects of various parameters, namely interest rate, life of the system and the maintenance cost have been taken into account. The comparative cost of distilled water produced from passive solar still (Rs. 0.70/kg) is found to be less than hybrid (PV/T) active solar still (Rs. 1.93/kg) for 30 years life time of the systems. The payback periods of the passive and hybrid (PV/T) active solar still are estimated to be in the range of 1.1-6.2 years and 3.3-23.9 years, respectively, based on selling price of distilled water in the range of Rs. 10/kg to Rs. 2/kg. The energy payback time (EPBT) has been estimated as 2.9 and 4.7 years, respectively. (author)

  15. Concentrating PV/T Hybrid System for Simultaneous Electricity and Usable Heat Generation: A Review

    Directory of Open Access Journals (Sweden)

    Longzhou Zhang

    2012-01-01

    Full Text Available Photovoltaic (PV power generation is one of the attractive choices for efficient utilization of solar energy. Considering that the efficiency and cost of PV cells cannot be significantly improved in near future, a relatively cheap concentrator to replace part of the expensive solar cells could be used. The photovoltaic thermal hybrid system (PV/T, combining active cooling with thermal electricity and providing both electricity and usable heat, can enhance the total efficiency of the system with reduced cell area. The effect of nonuniform light distribution and the heat dissipation on the performance of concentrating PV/T was discussed. Total utilization of solar light by spectral beam splitting technology was also introduced. In the last part, we proposed an integrated compound parabolic collector (CPC plate with low precision solar tracking, ensuring effective collection of solar light with a significantly lowered cost. With the combination of beam splitting of solar spectrum, use of film solar cell, and active liquid cooling, efficient and full spectrum conversion of solar light to electricity and heat, in a low cost way, might be realized. The paper may offer a general guide to those who are interested in the development of low cost concentrating PV/T hybrid system.

  16. Lapse in Institutional Animal Care and Use Committee Continuing Reviews.

    Directory of Open Access Journals (Sweden)

    Min-Fu Tsan

    Full Text Available The United States federal animal welfare regulations and the Public Health Service Policy on Humane Care and Use of Laboratory Animals require that institutional animal care and use committees (IACUCs conduct continuing reviews of all animal research activities. However, little is known about the lapse rate of IACUC continuing reviews, and how frequently investigators continue research activities during the lapse. It is also not clear what factors may contribute to an institution's lapse in IACUC continuing reviews. As part of the quality assurance program, the Department of Veterans Affairs (VA has collected performance metric data for animal care and use programs since 2011. We analyzed IACUC continuing review performance data at 74-75 VA research facilities from 2011 through 2015. The IACUC continuing review lapse rates improved from 5.6% in 2011 to 2.7% in 2015. The rate of investigators continuing research activities during the lapse also decreased from 47.2% in 2012 to 7.4% in 2015. The type of IACUCs used and the size of animal research programs appeared to have no effect in facility's rates of lapse in IACUC continuing reviews. While approximately 80% of facilities reported no lapse in IACUC continuing reviews, approximately 14% of facilities had lapse rates of >10% each year. Some facilities appeared to be repeat offenders. Four facilities had IACUC lapse rates of >10% in at least 3 out of 5 years, suggesting a system problem in these facilities requiring remedial actions to improve their IACUC continuing review processes.

  17. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  18. Analysis of concentrating PV-T systems for the commercial/industrial sector. Volume II. PV-T state-of-the-art survey and site/application pair selection and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schwinkendorf, W.E.

    1984-09-01

    As part of a project to develop feasibility assessments, design procedures, and reference designs for total energy systems that could use actively cooled concentrating photovoltaic collectors, a survey was conducted to provide an overview of available photovoltaic-thermal (PV-T) technology. General issues associated with the design and installation of a PV-T system are identified. Electrical and thermal efficiencies for the line-focus Fresnel, the linear parabolic trough, and the point-focus Fresnel collectors are specified as a function of operating temperature, ambient temperature, and insolation. For current PV-T technologies, the line-focus Fresnel collector proved to have the highest thermal and electrical efficiencies, lowest array cost, and lowest land area requirement. But a separate feasibility analysis involving 11 site/application pairs showed that for most applications, the cost of the photovoltaic portion of a PV-T system is not recovered through the displacement of an electrical load, and use of a thermal-only system to displace the thermal load would be a more economical alternative. PV-T systems are not feasible for applications that have a small thermal load, a large steam requirement, or a high load return temperature. SAND82-7157/3 identifies the technical issues involved in designing a photovoltaic-thermal system and provides guidance for resolving such issues. Detailed PV-T system designs for three selected applications and the results of a trade-off study for these applications are presented in SAND82-7157/4. A summary of the major results of this entire study and conclusions concerning PV-T systems and applications is presented in SAND82-7157/1.

  19. The tropical lapse rate steepened during the Last Glacial Maximum

    NARCIS (Netherlands)

    Loomis, S.E.; Russell, J.M.; Verschuren, D.; Morrill, C.; De Cort, G.; Sinninghe Damsté, J.S.; Olago, D.; Eggermont, H.; Street-Perrott, F.A.; Kelly, M.A.

    2017-01-01

    The gradient of air temperature with elevation (the temperature lapse rate) in the tropics is predicted to become lesssteep during the coming century as surface temperature rises, enhancing the threat of warming in high-mountainenvironments. However, the sensitivity of the lapse rate to climate

  20. Lapse ülalpidamise hind / Ene-Margit Tiit

    Index Scriptorium Estoniae

    Tiit, Ene-Margit, 1934-

    2005-01-01

    Tutvustav artikkel sotsiaalministeeriumi tellimusel läbiviidud uuringust, mille eesmärgiks oli välja töötada lapse kõikidest vajadustest lähtuv ühtne metoodika lapse ülalpidamiskulude arvutamiseks ühes kuus. Tabelid. Diagrammid. Vt. ka lk. 15-16: Kaplan, Signe. Metoodika kasutamisvõimalusi

  1. The tropical lapse rate steepened during the Last Glacial Maximum

    NARCIS (Netherlands)

    Loomis, Shannon E; Russell, James M; Verschuren, Dirk; Morrill, Carrie; De Cort, Gijs; Sinninghe Damsté, Jaap S; Olago, Daniel; Eggermont, Hilde; Street-Perrott, F Alayne; Kelly, Meredith A

    The gradient of air temperature with elevation (the temperature lapse rate) in the tropics is predicted to become less steep during the coming century as surface temperature rises, enhancing the threat of warming in high-mountain environments. However, the sensitivity of the lapse rate to climate

  2. Time-Lapse Videos for Physics Education: Specific Examples

    Science.gov (United States)

    Vollmer, Michael; Möllmann, Klaus-Peter

    2018-01-01

    There are many physics experiments with long time scales such that they are usually neither shown in the physics class room nor in student labs. However, they can be easily recorded with time-lapse cameras and the respective time-lapse videos allow qualitative and/or quantitative analysis of the underlying physics. Here, we present some examples…

  3. Susceptibility of memory consolidation during lapses in recall.

    Science.gov (United States)

    Marra, Vincenzo; O'Shea, Michael; Benjamin, Paul R; Kemenes, Ildikó

    2013-01-01

    Memories that can be recalled several hours after learning may paradoxically become inaccessible for brief periods after their formation. This raises major questions about the function of these early memory lapses in the structure of memory consolidation. These questions are difficult to investigate because of the lack of information on the precise timing of lapses. However, the use of a single-trial conditioning paradigm in Lymnaea solves this problem. Here we use electrophysiological and behavioural experiments to reveal lapses in memory recall at 30 min and 2 h post conditioning. We show that only during these lapses is consolidation of long-term memory susceptible to interruption by external disturbance. These shared time points of memory lapse and susceptibility correspond to transitions between different phases of memory that have different molecular requirements. We propose that during periods of molecular transition memory recall is weakened, allowing novel sensory cues to block the consolidation of long-term memory.

  4. Long non-coding RNA PVT1 as a novel potential biomarker for predicting the prognosis of colorectal cancer.

    Science.gov (United States)

    Fan, Heng; Zhu, Jian-Hua; Yao, Xue-Qing

    2018-05-01

    Long non-coding RNA (lncRNA) plays a very important role in the occurrence and development of various tumors, and is a potential biomarker for cancer diagnosis and prognosis. The purpose of this study was to investigate the relationship between the expression of lncRNA plasmacytoma variant translocation 1 (PVT1) and the prognostic significance in patients with colorectal cancer. The expression of PVT1 was measured by real-time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) in cancerous and adjacent tissues of 210 colorectal cancer patients. The disease-free survival and overall survival of colorectal cancer patients were evaluated by Kaplan-Meier analysis, and univariate and multivariate analysis were performed by Cox proportional-hazards model. Our results revealed that PVT1 expression in cancer tissues of colorectal cancer was significantly higher than that of adjacent tissues ( Pcolorectal cancer patients, whether at TNM I/II stage or at TNM III/IV stage. A multivariate Cox regression analysis demonstrated that high PVT1 expression was an independent predictor of poor prognosis in colorectal cancer patients. Our results suggest that high PVT1 expression might be a potential biomarker for assessing tumor recurrence and prognosis in colorectal cancer patients.

  5. Simple PVT quantitative method of Kr under high pure N2 condition

    International Nuclear Information System (INIS)

    Li Xuesong; Zhang Zibin; Wei Guanyi; Chen Liyun; Zhai Lihua

    2005-01-01

    A simple PVT quantitative method of Kr in the high pure N 2 was studied. Pressure, volume and temperature of the sample gas were measured by three individual methods to obtain the sum sample with food uncertainty. The ratio of Kr/N 2 could measured by GAM 400 quadrupole mass spectrometer. So the quantity of Kr could be calculated with the two measured data above. This method can be suited for quantitative analysis of other simple composed noble gas sample with high pure carrying gas. (authors)

  6. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  7. Design, fabrication and performance of a hybrid photovoltaic/thermal (PV/T) active solar still

    International Nuclear Information System (INIS)

    Kumar, Shiv; Tiwari, Arvind

    2010-01-01

    Two solar stills (single slope passive and single slope photovoltaic/thermal (PV/T) active solar still) were fabricated and tested at solar energy park, IIT New Delhi (India) for composite climate. Photovoltaic operated DC water pump was used between solar still and photovoltaic (PV) integrated flat plate collector to re-circulate the water through the collectors and transfer it to the solar still. The newly designed hybrid (PV/T) active solar still is self-sustainable and can be used in remote areas, need to transport distilled water from a distance and not connected to grid, but blessed with ample solar energy. Experiments were performed for 0.05, 0.10, and 0.15 m water depth, round the year 2006-2007 for both the stills. It has been observed that maximum daily yield of 2.26 kg and 7.22 kg were obtained from passive and hybrid active solar still, respectively at 0.05 m water depth. The daily yield from hybrid active solar still is around 3.2 and 5.5 times higher than the passive solar still in summer and winter month, respectively. The study has shown that this design of the hybrid active solar still also provides higher electrical and overall thermal efficiency, which is about 20% higher than the passive solar still.

  8. Investigations on the performance of a double pass, hybrid - type (PV/T) solar air heater

    Energy Technology Data Exchange (ETDEWEB)

    Srinivas, M.; Jayaraj, S. [Department of Mechanical Engineering, National Institute of Technology, Calicut-673601 (India)

    2013-07-01

    A solar hybrid energy system having photovoltaic and thermal (PV/T) devices, which produces both thermal and electrical energies simultaneously is considered for analysis. A double pass hybrid solar air (PV/T) heater with slats is designed and fabricated to study its thermal and electrical performance. Air as a heat removing fluid is made to flow through upper and lower channels of the collector. The collector is designed in such a way that the absorber plate is partially covered by solar cells. The raise in temperature of the solar cell is expected to decrease its electrical performance. Thin metallic strips called slats are attached longitudinally at the bottom side of the absorber plate to improve the system performance by increasing the cooling rate of the absorber plate. Thermal and electrical performances of the whole system at varying cooling conditions are presented. An artificial neural network model is used for forecasting the system performance at any desired conditions. The proposed model can be successfully used for evaluating the effect of different operating parameters under different ambient conditions for predicting the overall performance of the system.

  9. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  10. Time-lapse videos for physics education: specific examples

    Science.gov (United States)

    Vollmer, Michael; Möllmann, Klaus-Peter

    2018-05-01

    There are many physics experiments with long time scales such that they are usually neither shown in the physics class room nor in student labs. However, they can be easily recorded with time-lapse cameras and the respective time-lapse videos allow qualitative and/or quantitative analysis of the underlying physics. Here, we present some examples from thermal physics (melting, evaporation, cooling) as well as diffusion processes

  11. Outdoor Performance Analysis of a Photovoltaic Thermal (PVT) Collector with Jet Impingement and Compound Parabolic Concentrator (CPC).

    Science.gov (United States)

    Jaaz, Ahed Hameed; Hasan, Husam Abdulrasool; Sopian, Kamaruzzaman; Kadhum, Abdul Amir H; Gaaz, Tayser Sumer; Al-Amiery, Ahmed A

    2017-08-01

    This paper discusses the effect of jet impingement of water on a photovoltaic thermal (PVT) collector and compound parabolic concentrators (CPC) on electrical efficiency, thermal efficiency and power production of a PVT system. A prototype of a PVT solar water collector installed with a jet impingement and CPC has been designed, fabricated and experimentally investigated. The efficiency of the system can be improved by using jet impingement of water to decrease the temperature of the solar cells. The electrical efficiency and power output are directly correlated with the mass flow rate. The results show that electrical efficiency was improved by 7% when using CPC and jet impingement cooling in a PVT solar collector at 1:00 p.m. (solar irradiance of 1050 W/m² and an ambient temperature of 33.5 °C). It can also be seen that the power output improved by 36% when using jet impingement cooling with CPC, and 20% without CPC in the photovoltaic (PV) module at 1:30 p.m. The short-circuit current I SC of the PV module experienced an improvement of ~28% when using jet impingement cooling with CPC, and 11.7% without CPC. The output of the PV module was enhanced by 31% when using jet impingement cooling with CPC, and 16% without CPC.

  12. Outdoor Performance Analysis of a Photovoltaic Thermal (PVT Collector with Jet Impingement and Compound Parabolic Concentrator (CPC

    Directory of Open Access Journals (Sweden)

    Ahed Hameed Jaaz

    2017-08-01

    Full Text Available This paper discusses the effect of jet impingement of water on a photovoltaic thermal (PVT collector and compound parabolic concentrators (CPC on electrical efficiency, thermal efficiency and power production of a PVT system. A prototype of a PVT solar water collector installed with a jet impingement and CPC has been designed, fabricated and experimentally investigated. The efficiency of the system can be improved by using jet impingement of water to decrease the temperature of the solar cells. The electrical efficiency and power output are directly correlated with the mass flow rate. The results show that electrical efficiency was improved by 7% when using CPC and jet impingement cooling in a PVT solar collector at 1:00 p.m. (solar irradiance of 1050 W/m2 and an ambient temperature of 33.5 °C. It can also be seen that the power output improved by 36% when using jet impingement cooling with CPC, and 20% without CPC in the photovoltaic (PV module at 1:30 p.m. The short-circuit current ISC of the PV module experienced an improvement of ~28% when using jet impingement cooling with CPC, and 11.7% without CPC. The output of the PV module was enhanced by 31% when using jet impingement cooling with CPC, and 16% without CPC.

  13. Development of a cloud-based system for remote monitoring of a PVT panel

    Science.gov (United States)

    Saraiva, Luis; Alcaso, Adérito; Vieira, Paulo; Ramos, Carlos Figueiredo; Cardoso, Antonio Marques

    2016-10-01

    The paper presents a monitoring system developed for an energy conversion system based on the sun and known as thermophotovoltaic panel (PVT). The project was implemented using two embedded microcontrollers platforms (arduino Leonardo and arduino yún), wireless transmission systems (WI-FI and XBEE) and net computing ,commonly known as cloud (Google cloud). The main objective of the project is to provide remote access and real-time data monitoring (like: electrical current, electrical voltage, input fluid temperature, output fluid temperature, backward fluid temperature, up PV glass temperature, down PV glass temperature, ambient temperature, solar radiation, wind speed, wind direction and fluid mass flow). This project demonstrates the feasibility of using inexpensive microcontroller's platforms and free internet service in theWeb, to support the remote study of renewable energy systems, eliminating the acquisition of dedicated systems typically more expensive and limited in the kind of processing proposed.

  14. Nighttime radiative cooling potential of unglazed and PV/T solar collectors: parametric and experimental analyses

    DEFF Research Database (Denmark)

    Pean, Thibault Quentin; Gennari, Luca; Olesen, Bjarne W.

    2015-01-01

    Nighttime radiative cooling technology has been studied both by means of simulations and experiments, to evaluate its potential and to validate the existing theoretical models used to describe it. Photovoltaic/thermal panels (PV/T) and unglazed solar collectors have been chosen as case studies....... The obtained values showed a good agreement with the ones found in the literature about solar panels or other kinds of heat sinks used for radiative cooling applications. The panels provided a cooling performance per night ranging between 0.2 and 0.9 kWh/m2 of panel. The COP values (defined as the ratio....... An experimental setup has been constructed and tested during summer of 2014, at the Technical University of Denmark. The cooling performance (heat loss) has been measured simultaneously for both types of panels, installed side-by-side. The experimental results have been compared with the results from a commercial...

  15. Compensation of PVT Variations in ToF Imagers with In-Pixel TDC.

    Science.gov (United States)

    Vornicu, Ion; Carmona-Galán, Ricardo; Rodríguez-Vázquez, Ángel

    2017-05-09

    The design of a direct time-of-flight complementary metal-oxide-semiconductor (CMOS) image sensor (dToF-CIS) based on a single-photon avalanche-diode (SPAD) array with an in-pixel time-to-digital converter (TDC) must contemplate system-level aspects that affect its overall performance. This paper provides a detailed analysis of the impact of process parameters, voltage supply, and temperature (PVT) variations on the time bin of the TDC array. Moreover, the design and characterization of a global compensation loop is presented. It is based on a phase locked loop (PLL) that is integrated on-chip. The main building block of the PLL is a voltage-controlled ring-oscillator (VCRO) that is identical to the ones employed for the in-pixel TDCs. The reference voltage that drives the master VCRO is distributed to the voltage control inputs of the slave VCROs such that their multiphase outputs become invariant to PVT changes. These outputs act as time interpolators for the TDCs. Therefore the compensation scheme prevents the time bin of the TDCs from drifting over time due to the aforementioned factors. Moreover, the same scheme is used to program different time resolutions of the direct time-of-flight (ToF) imager aimed at 3D ranging or depth map imaging. Experimental results that validate the analysis are provided as well. The compensation loop proves to be remarkably effective. The spreading of the TDCs time bin is lowered from: (i) 20% down to 2.4% while the temperature ranges from 0 °C to 100 °C; (ii) 27% down to 0.27%, when the voltage supply changes within ±10% of the nominal value; (iii) 5.2 ps to 2 ps standard deviation over 30 sample chips, due to process parameters' variation.

  16. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  17. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.

  18. Susceptibility of memory consolidation during lapses in recall

    Science.gov (United States)

    Marra, Vincenzo; O’Shea, Michael; Benjamin, Paul R.; Kemenes, Ildikó

    2013-01-01

    Memories that can be recalled several hours after learning may paradoxically become inaccessible for brief periods after their formation. This raises major questions about the function of these early memory lapses in the structure of memory consolidation. These questions are difficult to investigate because of the lack of information on the precise timing of lapses. However, the use of a single-trial conditioning paradigm in Lymnaea solves this problem. Here we use electrophysiological and behavioural experiments to reveal lapses in memory recall at 30 min and 2 h post conditioning. We show that only during these lapses is consolidation of long-term memory susceptible to interruption by external disturbance. These shared time points of memory lapse and susceptibility correspond to transitions between different phases of memory that have different molecular requirements. We propose that during periods of molecular transition memory recall is weakened, allowing novel sensory cues to block the consolidation of long-term memory. PMID:23481386

  19. Lapse parimate huvide kaitse lapseröövi menetluses : [magistritöö] / Reeli Tambek ; Tartu Ülikool, õigusteaduskond ; juhendaja: Maarja Torga

    Index Scriptorium Estoniae

    Tambek, Reeli

    2012-01-01

    Lapse parimatest huvidest, kahe Euroopa suurima kohtu erinevast praktikast ja sellest tingitud ohtudest, õige tasakaalu saavutamise vajadusest ning viisidest lapse parimate huvide ja lapse tagastamise kohustuse vahel

  20. Kohtu loal lapse nimel tehingute tegemine krediidiasutuses : [magistritöö] / Merily Saar ; Tartu Ülikool, õigusteaduskond ; juhendaja: Triin Göttig

    Index Scriptorium Estoniae

    Saar, Merily, 1987-

    2013-01-01

    Varahooldusõigusest tulenevast lapse vara säilitamise kohustusest, perekonnaseadusest tulenevatest piirangutest vanema poolt lapse esindajana tehingute tegemisel, lapse nimel väärtpaberitehingute tegemisest

  1. The influence of lapses of attention on working memory capacity.

    Science.gov (United States)

    Unsworth, Nash; Robison, Matthew K

    2016-02-01

    In three experiments, the influence of lapses of attention on working memory (WM) capacity measures was examined. Participants performed various change detection tasks while also reporting whether they were focused on the current task or whether they were unfocused and mind-wandering. Participants reported that they were mind-wandering roughly 27% of the time, and when participants reported mind-wandering, their performance was worse compared to when they reported being on-task. Low WM capacity individuals reported more mind-wandering and lapses of attention than high WM capacity individuals, and mind-wandering and filtering abilities were shown to make independent contributions to capacity estimates. These results provide direct support for the notion that the ability to focus attention on-task and prevent lapses of attention is an important contributor to performance on measures of WM capacity.

  2. Influence of CO{sup 2} on PVT properties of an oil crude at high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nilo Ricardo; Bonet, Euclides Jose [Centro de Estudos de Petroleo (CEPETRO/UNICAMP), SP (Brazil); Elias Junior, Antonio; Trevisan, Osvair Vidal [Universidade Estadual de Campinas (DEP/FEM/UNICAMP), SP (Brazil). Fac. de Engenharia Mecanica. Dept. de Engenharia de Petroleo

    2012-07-01

    The current oil frontier in Brazil is in Santos and Campos Basins, where huge oil accumulations were identified recently. Well tests have shown high values of pressure and concentration of carbon dioxide in these reservoirs. The characterization of the fluids existing in the pores of the reservoir rocks is a task for the exploitation of the hydrocarbons. The objective of this work is to present the experimental set up that was assembled to perform PVT analysis for oils at high pressure, moderate temperature and high CO{sub 2} content, oils analogous to that found in the new Brazilian pre-salt discoveries. Samples of dead oil and synthetic gas were received at the laboratory, where the recombination was carried out to obtain live oil, with twelve mole percent CO{sub 2}. The fluids were maintained inside special cylinders, with a floating piston, separating two compartments, one with the test fluid and the other with hydraulic fluid. Pressure was provided by a positive displacement pump connected to the bottles. The experiments achieved pressures up to 70 MPa at constant temperature, conditions expected for the reservoir. Starting at the high pressure, the fluid volume was increased by withdrawing the hydraulic fluid from the cylinder. Pressure and volume were recorded to determine the bubble point and compressibility of the system. The pressure drop continued until the mixture was in the two phase region, finishing the constant composition expansion process. After that, the sample was re-pressurized and the PVT bottle was agitated to reach the thermodynamic equilibrium, when the live oil was at single phase again. An aliquot of this mixture was transferred, keeping their pressure and temperature conditions, to a high pressure viscometer and to a densimeter. Another portion of live oil was flashed to a test tube and to a gasometer, to render the gas oil ratio. Afterwards, successive additions of carbon dioxide increased its concentration in live oil to 15, 20 and 35

  3. EXERGY AND CARBON CREDITS FOR SERIES CONNECTED N PHOTOVOLTAIC THERMAL - COMPOUND PARABOLIC CONCENTRATOR (PVT-CPC) COLLECTOR: AT CONSTANT OUTLET TEMPERATURE

    OpenAIRE

    Rohit Tripathi 1,*, G. N. Tiwari 2

    2017-01-01

    In the present study, overall energy and exergy performance of partially covered N photovoltaic thermal - compound parabolic concentrators (PVT-CPC) (25% covered by glass to glass PV module) collector connected in series have been carried out at constant outlet temperature mode. Further, comparison in performance for partially covered N photovoltaic thermal - compound parabolic concentrators (PVT-CPC) [case (i)] and N compound parabolic concentrators (CPC) collector [case (ii)] connected in s...

  4. Performance of Partially Covered N Number of Photovoltaic Thermal (PVT) - Compound Parabolic Concentrator (CPC) Series Connected Water Heating System

    OpenAIRE

    Rohit Tripathi; Sumit Tiwari; G. N. Tiwari

    2016-01-01

    In present study, an approach is adopted where photovoltaic thermal flat plate collector is integrated with compound parabolic concentrator. Analytical expression of temperature dependent electrical efficiency of N number of partially covered Photovoltaic Thermal (PVT) - Compound Parabolic Concentrator (CPC) water collector connected in series has been derived with the help of basic thermal energy balance equations. Analysis has been carried for winter weather condition at Delhi location, Ind...

  5. Evidence for the role of horizontal transfer in generating pVT1, a large mosaic conjugative plasmid from the clam pathogen, Vibrio tapetis.

    Directory of Open Access Journals (Sweden)

    Gaël Erauso

    Full Text Available The marine bacterium Vibrio tapetis is the causative agent of the brown ring disease, which affects the clam Ruditapes philippinarum and causes heavy economic losses in North of Europe and in Eastern Asia. Further characterization of V. tapetis isolates showed that all the investigated strains harbored at least one large plasmid. We determined the sequence of the 82,266 bp plasmid pVT1 from the CECT4600(T reference strain and analyzed its genetic content. pVT1 is a mosaic plasmid closely related to several conjugative plasmids isolated from Vibrio vulnificus strains and was shown to be itself conjugative in Vibrios. In addition, it contains DNA regions that have similarity with several other plasmids from marine bacteria (Vibrio sp., Shewanella sp., Listonella anguillarum and Photobacterium profundum. pVT1 contains a number of mobile elements, including twelve Insertion Sequences or inactivated IS genes and an RS1 phage element related to the CTXphi phage of V. cholerae. The genetic organization of pVT1 underscores an important role of horizontal gene transfer through conjugative plasmid shuffling and transposition events in the acquisition of new genetic resources and in generating the pVT1 modular organization. In addition, pVT1 presents a copy number of 9, relatively high for a conjugative plasmid, and appears to belong to a new type of replicon, which may be specific to Vibrionaceae and Shewanelleacae.

  6. Review on the Recent Developments of Photovoltaic Thermal (PV/T and Proton Exchange Membrane Fuel Cell (PEMFC Based Hybrid System

    Directory of Open Access Journals (Sweden)

    Zulkepli Afzam

    2016-01-01

    Full Text Available Photovoltaic Thermal (PV/T system emerged as one of the convenient type of renewable energy system acquire the ability to generate power and thermal energy in the absence of moving parts. However, the power output of PV/T is intermittent due to dependency on solar irradiation condition. Furthermore, its efficiency decreases because of cells instability at high temperature. On the other hand, fuel cell co-generation system (CGS is another technology that can generate power and heat simultaneously. Integration of PV/T and fuel cell CGS could enhance the reliability and sustainability of both systems as well as increasing the overall system performance. Hence, this paper intended to present the parameters that affect performance of PV/T and Proton Exchange Membrane Fuel Cell (PEMFC CGS. Moreover, recent developments on PV/T-fuel cell hybrid system are also presented. Based on literates, mass flow rate of moving fluid in PV/T was found to affect the system efficiency. For the PEMFC, when the heat is utilized, the system performance can be increased where the heat efficiency is similar to electrical efficiency which is about 50%. Recent developments of hybrid PV/T and fuel cell show that most of the studies only focus on the power generation of the system. There are less study on the both power and heat utilization which is indeed necessary in future development in term of operation strategy, optimization of size, and operation algorithm.

  7. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T system against conventional photovoltaic (PV system

    Directory of Open Access Journals (Sweden)

    Peng Xu

    2015-11-01

    Full Text Available Photovoltaic (PV semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the overall field system involved 15 stand-alone PV panels and 15 retrofitted PV/T panels. The laboratory testing results demonstrated the PV/T panel could achieve the electrical efficiency of about 16.8% (relatively 5% improvement comparing with the stand-alone PV panel, and yield an extra amount of heat with thermal efficiency of nearly 65%. The field testing results indicated that the hybrid PV/T panel could enhance the electrical return of PV panels by nearly 3.5%, and increase the overall energy output by nearly 324.3%. Further opportunities and challenges were then discussed from aspects of different PV/T stakeholders to accelerate the development. It is expected that such technology could become a significant solution to yield more electricity, offset heating load freely and reduce carbon footprint in contemporary energy environment.

  8. Energy and exergy analysis of a two pass photovoltaic –thermal (PV/T) air heater

    Energy Technology Data Exchange (ETDEWEB)

    Srinivas, M.; Jayaraj, S. [Department of Mechanical Engineering, National Institute of Technology, Calicut-673601 (India)

    2013-07-01

    A double pass hybrid solar air (PV/T) heater with slats is designed and fabricated to study elaborately its thermal and electrical performance corresponding to the warm and humid environment. Air as a heat removing fluid is made to flow through upper and lower channels of the collector. The collector is designed in such way that the absorber plate is partially covered by solar cells. Thin metallic strips (called slats) are attached longitudinally at the bottom side of the absorber plate to improve the overall system performance (by increasing the cooling rate of the absorber plate). Thermal and electrical performances of the whole system at different cooling rates are presented. The exergy analysis of double pass hybrid solar air (PV/T) heater with slats has also been carried out. The instantaneous overall energy and overall exergy efficiency of the double pass hybrid (PV/T) solar air heater varies between 29 – 37 percent and 14-17 percent respectively. These obtained values are comparable with that of published results.

  9. Energetic performance analysis of a commercial water-based photovoltaic thermal system (PV/T) under summer conditions

    Science.gov (United States)

    Nardi, I.; Ambrosini, D.; de Rubeis, T.; Paoletti, D.; Muttillo, M.; Sfarra, S.

    2017-11-01

    In the last years, the importance of integrating the production of electricity with the production of sanitary hot water led to the development of new solutions, i.e. PV/T systems. It is well known that hybrid photovoltaic-thermal systems, able to produce electricity and thermal energy at the same time with better energetic performance in comparison with two separate systems, present many advantages for application in a residential building. A PV/T is constituted generally by a common PV panel with a metallic pipe, in which fluid flows. Pipe accomplishes two roles: it absorbs the heat from the PV panel, thus increasing, or at least maintaining its efficiency; furthermore, it stores the heat for sanitary uses. In this work, the thermal and electrical efficiencies of a commercial PV/T panel have been evaluated during the summer season in different days, to assess the effect of environmental conditions on the system total efficiency. Moreover, infrared thermographic diagnosis in real time has been effected during the operating mode in two conditions: with cooling and without cooling; cooling was obtained by natural flowing water. This analysis gave information about the impact of a non-uniform temperature distribution on the thermal and electrical performance. Furthermore, measurements have been performed in two different operating modes: 1) production of solely electrical energy and 2) simultaneous production of thermal and electrical energy. Finally, total efficiency is largely increased by using a simple solar concentrator nearby the panel.

  10. Performance Study of Photovoltaic-Thermal (Pv/T) Solar Collector with ·-Grooved Absorber Plate

    International Nuclear Information System (INIS)

    Mohd Yusof Othman; Hafidz Ruslan; Kamaruzzaman Sopian; Jin, G.L.

    2009-01-01

    A hybrid photovoltaic-thermal solar collector has been designed, built and its performance has been studied. The advantage of the collector is that it can generate electricity and heat simultaneously. Photovoltaic module SHARP NE-80E2EA with maximum output power of 80 W was used to generate electricity. The module also acts as heat absorber of the collector. Single pass ·-groove collector made of aluminium sheet with 0.7 mm thickness has been used to collect heat generated. Study was conducted under a designed halogen lamps solar simulator with intensities set at 386 ± 8 Wm -2 and 817 ± 8 Wm -2 . The speed of air passing through the collector was set between (69.6 ± 2.2) x 10 -4 kg/s to (695.8 ± 2.2) x 10 -4 kg/s. The objective of the study is to compare the performance of PV/T collector with and without ·-groove absorber. The study found that the PV/T collector with ·-groove absorber plate has higher efficiency than the PV/T without ·-groove absorber. The electrical and thermal efficiencies are also increased when radiation intensity and speed of air increase. (author)

  11. Time-lapse controlled-source electromagnetics using interferometry

    NARCIS (Netherlands)

    Hunziker, J.W.; Slob, E.C.; Wapenaar, C.P.A.

    In time-lapse controlled-source electromagnetics, it is crucial that the source and the receivers are positioned at exactly the same location at all times of measurement. We use interferometry by multidimensional deconvolution (MDD) to overcome problems in repeatability of the source location.

  12. Andeka lapse arengukeskkond ja toimetulek koolis / Helle Sikka

    Index Scriptorium Estoniae

    Sikka, Helle

    2001-01-01

    Andekuse mõistest ja selle arengust, andeka lapse isiksuseomadustest. 1998-2000.a. läbi viidud küsitlusuuringust, mille eesmärgiks oli selgitada andekate laste koolimeeldivust, hinnanguid õpetajatele, õpilaste asendit kaaslaste seas, õpilaste arvamusi oma isiksuseomaduste kohta ning andekate harrastusi ja huvisid

  13. Energetic and exergetic performances analysis of a PV/T (photovoltaic thermal) solar system tested and simulated under to Tunisian (North Africa) climatic conditions

    International Nuclear Information System (INIS)

    Hazami, Majdi; Riahi, Ali; Mehdaoui, Farah; Nouicer, Omeima; Farhat, Abdelhamid

    2016-01-01

    The endeavor of this paper is to study the potential offered by the expenditure of a PV/T (photovoltaic thermal) solar system in Tunisian households. This investigation is performed according to two-folded approaches. Firstly, outdoor experiments were carried out during July 2014 for both passive and active mode. An exhaustive energy and exergy analysis was then performed to evaluate the instantaneous thermal and the electrical exergy outputs of the PV/T solar system. The results showed that the maximum instantaneous thermal and electric energy efficiency in active mode are about 50 and 15%, respectively. It was found also that the maximum thermal and electric exergy efficiencies were about 50 and 14.8%, respectively. The second approach is the evaluation of the monthly/annual performances of the PV/T solar system under typical climate area of Tunisia by using TRNSYS program. The results showed that the active mode enhances the electric efficiency and the exergy of the PV/T system by 3 and 2.5% points, respectively. The results showed that the optimized PV/T solar system covert the major part of the hot water and the electric needs of Tunisian household's with an expected annual average gain of about 14.60 and 5.33%, respectively. An economic appraisal was performed. - Highlights: • The present work studies the potential of using PV/T solar collector in Tunisian. • The maximum thermal and electric efficiencies are 50 and 15%, respectively. • The maximum thermal and electric exergy efficiencies were 50 and 14.8%. • The results showed that the expected annual gain are 14.60 and 5.33%. • The PV/T is compared to a high quality commercial solar collectors and a PV panel.

  14. AGENCY CONTRIBUTION IN ACHIEVING TEMPORARY AGENCY WORKERS’ ORGANIZATIONAL COMMITMENT: A STUDY IN ABC (PVT LTD

    Directory of Open Access Journals (Sweden)

    T.G.T.N Perera

    2017-12-01

    Full Text Available Temporary agency workers are coming under non-standard employments, who have temporary attachment to the working organization. With dynamic business environment and flexible work arrangements, temporary agency employments are also emerged in Sri Lanka. Temporary agency workers are dual committed employees. However, with this dual commitment, organizations face issues in achieving temporary agency workers’ commitment due to low attention of agencies to temporary agency workers. Even though the Client organization provides due attention to temporary agency workers, they fail to receive due commitment due to the lack of attention from agency to temporary agency workers. This study was conducted to identify the agency related factors affecting temporary agency workers’ commitment. This was carried out as a cross sectional field study with a sample of 93 workers from temporary agency works in the ABC (pvt ltd. 93 temporary agency workers were selected as sample. Data were collected via a standard questionnaire that met accepted standards of validity and reliability. Descriptive statistics, Simple ranking, Factor analysis, ANOVA and Independent Sample T-Test technique were performed to analyze data. No of Temporary workers to supervisor (temp to consult ratio is the most influencing factor of temporary agency workers’ commitment in agency context. Job satisfaction, agency support, side bets, interactional justice, lack of alternative employments, procedural justice, distributive justice, reciprocity norm acceptance, socialization, breach of psychological contract, lack of skill transferability are the other factors, which are ordered from most influencing factor to less affecting factor to workers’ organizational commitment . Findings revealed that eleven out of thirteen factors are job related factors, other two are organization related and person related factors. Most client companies provide their attention, while agencies fail to provide

  15. Are lapsed donors willing to resume blood donation, and what determines their motivation to do so?

    Science.gov (United States)

    van Dongen, Anne; Abraham, Charles; Ruiter, Robert A C; Schaalma, Herman P; de Kort, Wim L A M; Dijkstra, J Anneke; Veldhuizen, Ingrid J T

    2012-06-01

    This study investigated the possibility of rerecruiting lapsed blood donors. Reasons for donation cessation, motivation to restart donation, and modifiable components of donation motivation were examined. We distinguished between lapsed donors who had passively withdrawn by merely not responding to donation invitations and donors who had contacted the blood bank to actively withdraw. A cross-sectional survey was sent to 400 actively lapsed donors and to 400 passively lapsed donors, measuring intention to restart donation and psychological correlates of restart intention. The data were analyzed using multiple regression analyses. The response rate among actively lapsed donors was higher than among passively lapsed donors (37% vs. 25%). Actively lapsed donors typically ceased donating because of physical reactions, while passively lapsed donors quit because of a busy lifestyle. Nonetheless, 51% of actively lapsed responders and 80% of passively lapsed responders were willing to restart donations. Multiple regression analysis showed that, for passively lapsed donors, cognitive attitude was the strongest correlate of intention to donate in the future (β=0.605, pattitude (β=0.239, pattitude was also the strongest correlate of intention (β=0.601, pattitude (β=0.345, pattitudes and self-efficacy could further raise such intentions. © 2011 American Association of Blood Banks.

  16. Calibrating vadose zone models with time-lapse gravity data

    DEFF Research Database (Denmark)

    Christiansen, Lars; Binning, Philip John; Rosbjerg, Dan

    2011-01-01

    The vadose zone plays an important role in the hydrologic cycle. Various geophysical methods can determine soil water content variations in time and space in volumes ranging from a few cubic centimeters to several cubic meters. In contrast to the established methods, time-lapse gravity measurements...... of changes in soil water content do not rely on a petrophysical relationship between the measured quantity and the water content but give a direct measure of the mass change in the soil. Only recently has the vadose zone been systematically incorporated when ground-based gravity data are used to infer...... hydrologic information. In this study, changes in the soil water content gave rise to a measurable signal in a forced infiltration experiment on a 107-m2 grassland area. Time-lapse gravity data were able to constrain the van Genuchten soil hydraulic parameters in both a synthetic example and a field...

  17. Definition of "banner clouds" based on time lapse movies

    Directory of Open Access Journals (Sweden)

    J. H. Schween

    2007-01-01

    Full Text Available Banner clouds appear on the leeward side of a mountain and resemble a banner or a flag. This article provides a comprehensive definition of "banner clouds". It is based primarily on an extensive collection of time lapse movies, but previous attempts at an explanation of this phenomenon are also taken into account. The following ingredients are considered essential: the cloud must be attached to the mountain but not appear on the windward side; the cloud must originate from condensation of water vapour contained in the air (rather than consist of blowing snow; the cloud must be persistent; and the cloud must not be of convective nature. The definition is illustrated and discussed with the help of still images and time lapse movies taken at Mount Zugspitze in the Bavarian Alps.

  18. Data mining in forecasting PVT correlations of crude oil systems based on Type1 fuzzy logic inference systems

    Science.gov (United States)

    El-Sebakhy, Emad A.

    2009-09-01

    Pressure-volume-temperature properties are very important in the reservoir engineering computations. There are many empirical approaches for predicting various PVT properties based on empirical correlations and statistical regression models. Last decade, researchers utilized neural networks to develop more accurate PVT correlations. These achievements of neural networks open the door to data mining techniques to play a major role in oil and gas industry. Unfortunately, the developed neural networks correlations are often limited, and global correlations are usually less accurate compared to local correlations. Recently, adaptive neuro-fuzzy inference systems have been proposed as a new intelligence framework for both prediction and classification based on fuzzy clustering optimization criterion and ranking. This paper proposes neuro-fuzzy inference systems for estimating PVT properties of crude oil systems. This new framework is an efficient hybrid intelligence machine learning scheme for modeling the kind of uncertainty associated with vagueness and imprecision. We briefly describe the learning steps and the use of the Takagi Sugeno and Kang model and Gustafson-Kessel clustering algorithm with K-detected clusters from the given database. It has featured in a wide range of medical, power control system, and business journals, often with promising results. A comparative study will be carried out to compare their performance of this new framework with the most popular modeling techniques, such as neural networks, nonlinear regression, and the empirical correlations algorithms. The results show that the performance of neuro-fuzzy systems is accurate, reliable, and outperform most of the existing forecasting techniques. Future work can be achieved by using neuro-fuzzy systems for clustering the 3D seismic data, identification of lithofacies types, and other reservoir characterization.

  19. Definition of "banner clouds" based on time lapse movies

    OpenAIRE

    Schween , J. H.; Kuettner , J.; Reinert , D.; Reuder , J.; Wirth , V.

    2007-01-01

    International audience; Banner clouds appear on the leeward side of a mountain and resemble a banner or a flag. This article provides a comprehensive definition of "banner clouds". It is based primarily on an extensive collection of time lapse movies, but previous attempts at an explanation of this phenomenon are also taken into account. The following ingredients are considered essential: the cloud must be attached to the mountain but not appear on the windward side; the cloud must originate ...

  20. Findings of negligence followed communication lapses in BC aneurysm case

    OpenAIRE

    Capen, K

    1997-01-01

    Negligence is sometimes established on the basis of lapses in communication and patient care management that, in hindsight, could have been avoided. A recent BC court case concerned a patient who died because of a ruptured aneurysm. A Supreme Court judge found that some of the physicians involved had failed in their duty to diagnose the patient's condition properly, or failed to communicate to one another significant signs of the patient's illness, and failed to refer him in time to the medic...

  1. Time-lapse Raman imaging of osteoblast differentiation

    Science.gov (United States)

    Hashimoto, Aya; Yamaguchi, Yoshinori; Chiu, Liang-Da; Morimoto, Chiaki; Fujita, Katsumasa; Takedachi, Masahide; Kawata, Satoshi; Murakami, Shinya; Tamiya, Eiichi

    2015-07-01

    Osteoblastic mineralization occurs during the early stages of bone formation. During this mineralization, hydroxyapatite (HA), a major component of bone, is synthesized, generating hard tissue. Many of the mechanisms driving biomineralization remain unclear because the traditional biochemical assays used to investigate them are destructive techniques incompatible with viable cells. To determine the temporal changes in mineralization-related biomolecules at mineralization spots, we performed time-lapse Raman imaging of mouse osteoblasts at a subcellular resolution throughout the mineralization process. Raman imaging enabled us to analyze the dynamics of the related biomolecules at mineralization spots throughout the entire process of mineralization. Here, we stimulated KUSA-A1 cells to differentiate into osteoblasts and conducted time-lapse Raman imaging on them every 4 hours for 24 hours, beginning 5 days after the stimulation. The HA and cytochrome c Raman bands were used as markers for osteoblastic mineralization and apoptosis. From the Raman images successfully acquired throughout the mineralization process, we found that β-carotene acts as a biomarker that indicates the initiation of osteoblastic mineralization. A fluctuation of cytochrome c concentration, which indicates cell apoptosis, was also observed during mineralization. We expect time-lapse Raman imaging to help us to further elucidate osteoblastic mineralization mechanisms that have previously been unobservable.

  2. Energy performance of water hybrid PV/T collectors applied to combisystems of Direct Solar Floor type

    Energy Technology Data Exchange (ETDEWEB)

    Fraisse, G.; Johannes, K. [Laboratoire Optimisation de la Conception et Ingenierie de l' Environnement, Ecole Superieure d' Ingenieurs de Chambery, Campus Scientifique Savoie Technolac, 73376 Le Bourget du Lac Cedex (France); Menezo, C. [Centre de Thermique de Lyon, Domaine Scientifique de La Doua, Bat. Freyssinet, 20, Avenue A. Einstein, 69621 Villeurbanne Cedex (France)

    2007-11-15

    The integration of photovoltaic (PV) modules in buildings allows one to consider a multifunctional frame and then to reduce the cost by substitution of components. In order to limit the rise of the cell operating temperature, a photovoltaics/thermal (PV/T) collector combines a solar water heating collector and PV cells. The recovered heat energy can be used for heating systems and domestic hot water. A combination with a Direct Solar Floor is studied. Its low operating temperature level is appropriate for the operating conditions of the mono- or poly-crystalline photovoltaic modules which are selected in that study. However, for a system including a glass covered collector and localised in Macon area in France, we show that the annual photovoltaic cell efficiency is 6.8% which represents a decrease of 28% in comparison with a conventional non-integrated PV module of 9.4% annual efficiency. This is obviously due to a temperature increase related to the cover. On the other hand, we show that without a glass cover, the efficiency is 10% which is 6% better than a standard module due to the cooling effect. Moreover, in the case of a glazed PV/T collector with a conventional control system for Direct Solar Floor, the maximum temperature reached at the level of the PV modules is higher than 100{sup o}C. This is due to the oversize of the collectors during the summer when the heating needs are null, i.e. without a heated swimming pool for example. This temperature level does not allow the use of EVA resin (ethylene vinyl acetate) in PV modules due to strong risks of degradation. The current solution consists of using amorphous cells or, if we do not enhance the thermal production, uncovered PV/T collector. Further research led to water hybrid PV/T solar collectors as a one-piece component, both reliable and efficient, and including the thermal absorber, the heat exchanger and the photovoltaic functions. (author)

  3. PVT modeling of reservoir fluids using PC-SAFT EoS and Soave-BWR EoS

    DEFF Research Database (Denmark)

    Yan, Wei; Varzandeh, Farhad; Stenby, Erling Halfdan

    2015-01-01

    non-cubic EoS models, such as the Perturbed Chain Statistical Associating Fluid Theory (PC-SAFT) EoS and the Soave modified Benedict-Webb-Rubin (Soave-BWR) EoS, may partly replace the roles of these classical cubic models in the upstream oil industry. Here, we attempt to make a comparative study...... for the four models. For PVT prediction, the non-cubic models show advantages in some high pressure high temperature (HPHT) fluids but no clear advantages in general, indicating the necessity for further improvement of the characterization procedure....

  4. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  5. Methodology to characterize an unsampled oil interval, integrating PVT (Pressure/Volumen/Temperature) analysis and production log; Metodologia para caracterizacao de oleo de intervalo nao-amostrado, integrando analise PVT e perfil de producao

    Energy Technology Data Exchange (ETDEWEB)

    Marcon, Diogo Reato; Souza, Ana Paula Martins de; Vieira, Alexandre J.M. [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    This work presents a new methodology for characterizing an unsampled oil interval, using basically production log data and PVT analyses available in the well. The methodology was applied to a real case, where the live oil samples were collected during a well test run in three different depths, revealing some evidence of a compositional grading due to gravity. Each individual sample was a mixture of the fluid produced from the reservoir bottom to the sampling point, since the whole interval was perforated and the isolation had to be made with a packer. The first sample was corresponding to the mixture of lower and all upper oils. The other two samples are only the heavier and that oil with part of the one from the upper interval. In order to identify the fluid properties from the upper interval, needed for production development studies, the following procedure was devised: equation-of-state tuning, reproducing the sampled fluid properties; conversion of volumetric flowrates from production log into mass and molar flowrates; flowrate ratio calculation, between the upper and lower intervals; upper interval fluid composition estimative; upper interval fluid properties simulation, using the previously tuned equation-of-state, thus generating what was considered a representative, synthetic PVT analysis. (author)

  6. Numerical study on optical and electric-thermal performance for solar concentrating PV/T air system

    Institute of Scientific and Technical Information of China (English)

    SUN Jian; SHI MingHeng

    2009-01-01

    Hybrid photovoltaic/thermsl(PV/T)system with solar concentrator is an effective way to improve solar energy conversion efficiency.In this work,a single-pass PV/T sir system with a three-trough compound parabolic concentrator(CPC)of concentration ratio 2.0 is designed and the solar incident distributions at the solar cell surface are calculated by ray tracing method.Based on energy balance,the heat transfer models of all main components in this system are developed.The effects of some main designing and operational parameters on the electric-thermal performance of the system are analyzed.The results show that the solar radiation intensity can be higher than 1200 W/m~2 at most area of the cell surface.The temperature of the air and cell surface increases along the length of the system.Thus the system efficiency of the CPC is higher than that of the system without the CPC.The thermal efficiency,exergy and electrical efficiency of this CPC system increase with increasing of the air mass flow rate and the length of the system.With increasing packing fraction the electrical efficiency increases,but the thermal efficiency decreases.The exergy efficiency increases slightly with the packing fraction rising.The data obtained in this work are valuable for the design and operation for this kind of solar concentrating PV/T systems.

  7. Numerical study on optical and electric-thermal performance for solar concentrating PV/T air system

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Hybrid photovoltaic/thermal(PV/T)system with solar concentrator is an effective way to improve solar energy conversion efficiency.In this work,a single-pass PV/T air system with a three-trough compound parabolic concentrator(CPC)of concentration ratio 2.0 is designed and the solar incident distributions at the solar cell surface are calculated by ray tracing method.Based on energy balance,the heat transfer models of all main components in this system are developed.The effects of some main designing and operational parameters on the electric-thermal performance of the system are analyzed. The results show that the solar radiation intensity can be higher than 1200 W/m 2 at most area of the cell surface.The temperature of the air and cell surface increases along the length of the system.Thus the system efficiency of the CPC is higher than that of the system without the CPC.The thermal efficiency, exergy and electrical efficiency of this CPC system increase with increasing of the air mass flow rate and the length of the system.With increasing packing fraction the electrical efficiency increases,but the thermal efficiency decreases.The exergy efficiency increases slightly with the packing fraction rising.The data obtained in this work are valuable for the design and operation for this kind of solar concentrating PV/T systems.

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  9. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  10. Distinct coping strategies differentially predict urge levels and lapses in a smoking cessation attempt.

    Science.gov (United States)

    Brodbeck, Jeannette; Bachmann, Monica S; Znoj, Hansjörg

    2013-06-01

    This study analysed mechanisms through which stress-coping and temptation-coping strategies were associated with lapses. Furthermore, we explored whether distinct coping strategies differentially predicted reduced lapse risk, lower urge levels, or a weaker association between urge levels and lapses during the first week of an unassisted smoking cessation attempt. Participants were recruited via the internet and mass media in Switzerland. Ecological momentary assessment (EMA) with mobile devices was used to assess urge levels and lapses. Online questionnaires were used to measure smoking behaviours and coping variables at baseline, as well as smoking behaviour at the three-month follow-up. The sample consisted of 243 individuals, aged 20 to 40, who reported 4199 observations. Findings of multilevel regression analyses show that coping was mainly associated with a reduced lapse risk and not with lower urge levels or a weaker association between urge levels and lapses. 'Calming down' and 'commitment to change' predicted a lower lapse risk and also a weaker relation between urge levels and lapses. 'Stimulus control' predicted a lower lapse risk and lower urge levels. Conversely, 'task-orientation' and 'risk assessment' were related to higher lapse risk and 'risk assessment' also to higher urge levels. Disengagement coping i.e. 'eating or shopping', 'distraction', and 'mobilising social support' did not affect lapse risk. Promising coping strategies during the initial stage of smoking cessation attempt are targeted directly at reducing the lapse risk and are characterised by engagement with the stressor or one's reactions towards the stressor and a focus on positive consequences instead of health risks. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Predictors of lapse in first week of smoking abstinence in PTSD and non-PTSD smokers.

    Science.gov (United States)

    Beckham, Jean C; Calhoun, Patrick S; Dennis, Michelle F; Wilson, Sarah M; Dedert, Eric A

    2013-06-01

    Retrospective research suggests smokers with posttraumatic stress disorder (PTSD) lapse more quickly after their quit date. Ecological momentary assessment (EMA) research is needed to confirm the presence of early smoking lapse in PTSD and form conceptualizations that inform intervention. Smokers with (n = 55) and without (n = 52) PTSD completed alarm-prompted EMA of situational and psychiatric variables the week before and after a quit date, and self-initiated EMA following smoking lapses. Blood samples at baseline and on the quit date allowed assessment of dehydroepiandrosterone (DHEA) and dehydroepiandrosterone sulfate (DHEA(S)). PTSD was related to shorter time to lapse (hazard ratio [HR] = 1.677, 95% CI: 1.106-2.544). Increased smoking abstinence self-efficacy was related to longer time to lapse (HR = 0.608, 95% CI: 0.430-0.860). Analyses of participants' real-time reports revealed that smokers with PTSD were more likely to attribute first-time lapses to negative affect ( = 5.412, p = .020), and trauma reminders (Fisher's exact p = .003**). Finally, the quit date decrease in DHEA(S) was related to shorter time to lapse (HR = 1.009, 95% CI: 1.000-1.018, p smoking lapse in PTSD, and add to evidence that early lapse occasions are more strongly related to trauma reminders, negative affect, and cravings in smokers with PTSD.

  12. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  13. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  14. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  15. Interferometric full-waveform inversion of time-lapse data

    KAUST Repository

    Sinha, Mrinal

    2017-08-17

    One of the key challenges associated with time-lapse surveys is ensuring the repeatability between the baseline and monitor surveys. Non-repeatability between the surveys is caused by varying environmental conditions over the course of different surveys. To overcome this challenge, we propose the use of interferometric full waveform inversion (IFWI) for inverting the velocity model from data recorded by baseline and monitor surveys. A known reflector is used as the reference reflector for IFWI, and the data are naturally redatumed to this reference reflector using natural reflections as the redatuming operator. This natural redatuming mitigates the artifacts introduced by the repeatability errors that originate above the reference reflector.

  16. Predictive modeling of addiction lapses in a mobile health application.

    Science.gov (United States)

    Chih, Ming-Yuan; Patton, Timothy; McTavish, Fiona M; Isham, Andrew J; Judkins-Fisher, Chris L; Atwood, Amy K; Gustafson, David H

    2014-01-01

    The chronically relapsing nature of alcoholism leads to substantial personal, family, and societal costs. Addiction-comprehensive health enhancement support system (A-CHESS) is a smartphone application that aims to reduce relapse. To offer targeted support to patients who are at risk of lapses within the coming week, a Bayesian network model to predict such events was constructed using responses on 2,934 weekly surveys (called the Weekly Check-in) from 152 alcohol-dependent individuals who recently completed residential treatment. The Weekly Check-in is a self-monitoring service, provided in A-CHESS, to track patients' recovery progress. The model showed good predictability, with the area under receiver operating characteristic curve of 0.829 in the 10-fold cross-validation and 0.912 in the external validation. The sensitivity/specificity table assists the tradeoff decisions necessary to apply the model in practice. This study moves us closer to the goal of providing lapse prediction so that patients might receive more targeted and timely support. © 2013.

  17. Experimental investigation of the energy performance of a novel Micro-encapsulated Phase Change Material (MPCM) slurry based PV/T system

    International Nuclear Information System (INIS)

    Qiu, Zhongzhu; Ma, Xiaoli; Zhao, Xudong; Li, Peng; Ali, Samira

    2016-01-01

    Highlights: • An experimental investigation to a novel MPCM slurry based PV/T system was conducted. • The system had the reduced solar efficiency at a higher solar radiation. • The system had the increased solar efficiency at a higher slurry Reynolds number. • The most favourite MPCM concentration was around 10%. • The experimental results approved the accuracy of the established computer model. - Abstract: As a follow-on work of the authors’ theoretical study, the paper presented an experimental investigation into the energy performance of a novel PV/T thermal and power system employing the Micro-encapsulated Phase Change Material (MPCM) slurry as the working fluid. A prototype PV/T module of 800 mm × 1600 mm × 50 mm was designed and constructed based on the previous modelling recommendation. The performance of the PV/T module and associated thermal and power system were tested under various solar radiations, slurry Reynolds numbers and MPCM concentrations. It was found that (1) increasing solar radiation led to the increased PV/T module temperature, decreased solar thermal and electrical efficiencies and reduced slurry pressure drop; (2) increasing the slurry Reynolds number led to the increased solar thermal and electrical efficiencies, decreased module temperature, and increased pressure drop; and (3) increasing the MPCM concentration led to the reduced module temperature and increased pressure drop. The experimental results were used to examine the accuracy of the established computer model, giving a derivation scale ranging from 1.1% to 6.1% which is an acceptable error level for general engineering simulation. The recommended operational conditions of the PV/T system were (1) MPCM slurry weight concentration of 10%, (2) slurry Reynolds number of 3000, and (3) solar radiation of 500–700 W/m"2; at which the system could achieve the net overall solar efficiencies of 80.8–83.9%. To summarise, the MPCM slurry based PV/T thermal and power system

  18. Development of a dual-sinker densimeter for high-accuracy fluid P-V-T measurements

    International Nuclear Information System (INIS)

    McLinden, M.O.; Frederick, N.V.

    1993-01-01

    A dual-sinker densimeter to very accurately measure the pressure-volume-temperature (P-V-T) properties of fluids over a temperature range of 80 K to 520 K and at pressures up to 35 MPa is in the final stages of development at NIST. The density of a fluid is determined by measuring the difference in the buoyancy forces experienced by two sinkers of identical mass, surface area, and surface material, but very different volumes. The buoyancy forces on the sinkers are transmitted to a semi-microbalance by means of a magnetic suspension coupling. This paper reviews the principle of the measurement and describes the overall design of the system

  19. Energy and economic analysis of an On-grid PV/T system in a dairy farm in Chile

    International Nuclear Information System (INIS)

    Coca-Ortegón, Adriana; Atienza-Márquez, Antonio; Coronas, Alberto; Merino, Gabriel; Gontupi, Jorge; Salazar, Francisco

    2017-01-01

    The objective of this study is to evaluate the performance of an on-grid PV/T system in a dairy farm located in Osorno (Chile), operated under the Net-Metering scheme. All equipment installed in the farm is driven by electricity and the daily average electric consumption is 235 kWh. The study analyses first the existing installation, second a conventional solar installation (with photovoltaic and solar thermal technologies), and third a photovoltaic installation plus a photovoltaic-thermal hybrid installation. We did a sensibility analysis of the solar contribution factor to the self-consumption (electric and thermal), by varying the mass flow rate in the solar thermal circuit, and the energy storage size. This analysis allowed to optimize the sizing and the operation of the solar systems. The systems are compared in terms of annual energy production per unit area, unit price of energy produced and percentage of energy exported to the grid. (author)

  20. Mercury-free PVT apparatus for thermophysical property analyses of hydrocarbon reservoir fluids. Final report, August 16, 1990--July 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Lansangan, R.M.; Lievois, J.S.

    1992-08-31

    Typical reservoir fluid analyses of complex, multicomponent hydrocarbon mixtures include the volumetric properties, isothermal compressibility, thermal expansivity, equilibrium ratios, saturation pressure, viscosities, etc. These parameters are collectively referred to as PVT properties, an acronym for the primary state variables; pressure, volume, and temperature. The reservoir engineer incorporates this information together with the porous media description in performing material balance calculations. These calculations lead to the determination (estimation) of the initial hydrocarbon in-place, the future reservoir performance, the optimal production scheme, and the ultimate hydrocarbon recovery. About four years ago, Ruska Instrument Corporation embarked on a project to develop an apparatus designed to measure PVT properties that operates free of mercury. The result of this endeavor is the 2370 Hg-Free PVT system which has been in the market for the last three years. The 2370 has evolved from the prototype unit to its present configuration which is described briefly in this report. The 2370 system, although developed as a system-engineered apparatus based on existing technology, has not been exempt from this burden-of-proof Namely, the performance of the apparatus under routine test conditions with real reservoir fluids. This report summarizes the results of the performance and applications testing of the 2370 Hg-Free PVT system. Density measurements were conducted on a pure fluid. The results were compared against literature values and the prediction of an equation of state. Routine reservoir fluid analyses were conducted with a black oil and a retrograde condensate gas mixtures. Limited comparison of the results were performed based on the same tests performed on a conventional mercury-based PVT apparatus. The results of these tests are included in this report.

  1. Exploring Time-Lapse Photography as a Means for Qualitative Data Collection

    Science.gov (United States)

    Persohn, Lindsay

    2015-01-01

    Collecting information via time-lapse photography is nothing new. Scientists and artists have been using this kind of data since the late 1800s. However, my research and experiments with time-lapse have shown that great potential may lie in its application to educational and social scientific research methods. This article is part history, part…

  2. Capturing change: the duality of time-lapse imagery to acquire data and depict ecological dynamics

    Science.gov (United States)

    Brinley Buckley, Emma M.; Allen, Craig R.; Forsberg, Michael; Farrell, Michael; Caven, Andrew J.

    2017-01-01

    We investigate the scientific and communicative value of time-lapse imagery by exploring applications for data collection and visualization. Time-lapse imagery has a myriad of possible applications to study and depict ecosystems and can operate at unique temporal and spatial scales to bridge the gap between large-scale satellite imagery projects and observational field research. Time-lapse data sequences, linking time-lapse imagery with data visualization, have the ability to make data come alive for a wider audience by connecting abstract numbers to images that root data in time and place. Utilizing imagery from the Platte Basin Timelapse Project, water inundation and vegetation phenology metrics are quantified via image analysis and then paired with passive monitoring data, including streamflow and water chemistry. Dynamic and interactive time-lapse data sequences elucidate the visible and invisible ecological dynamics of a significantly altered yet internationally important river system in central Nebraska.

  3. Capturing change: the duality of time-lapse imagery to acquire data and depict ecological dynamics

    Directory of Open Access Journals (Sweden)

    Emma M. Brinley Buckley

    2017-09-01

    Full Text Available We investigate the scientific and communicative value of time-lapse imagery by exploring applications for data collection and visualization. Time-lapse imagery has a myriad of possible applications to study and depict ecosystems and can operate at unique temporal and spatial scales to bridge the gap between large-scale satellite imagery projects and observational field research. Time-lapse data sequences, linking time-lapse imagery with data visualization, have the ability to make data come alive for a wider audience by connecting abstract numbers to images that root data in time and place. Utilizing imagery from the Platte Basin Timelapse Project, water inundation and vegetation phenology metrics are quantified via image analysis and then paired with passive monitoring data, including streamflow and water chemistry. Dynamic and interactive time-lapse data sequences elucidate the visible and invisible ecological dynamics of a significantly altered yet internationally important river system in central Nebraska.

  4. Application of Machine Learning to Predict Dietary Lapses During Weight Loss.

    Science.gov (United States)

    Goldstein, Stephanie P; Zhang, Fengqing; Thomas, John G; Butryn, Meghan L; Herbert, James D; Forman, Evan M

    2018-05-01

    Individuals who adhere to dietary guidelines provided during weight loss interventions tend to be more successful with weight control. Any deviation from dietary guidelines can be referred to as a "lapse." There is a growing body of research showing that lapses are predictable using a variety of physiological, environmental, and psychological indicators. With recent technological advancements, it may be possible to assess these triggers and predict dietary lapses in real time. The current study sought to use machine learning techniques to predict lapses and evaluate the utility of combining both group- and individual-level data to enhance lapse prediction. The current study trained and tested a machine learning algorithm capable of predicting dietary lapses from a behavioral weight loss program among adults with overweight/obesity (n = 12). Participants were asked to follow a weight control diet for 6 weeks and complete ecological momentary assessment (EMA; repeated brief surveys delivered via smartphone) regarding dietary lapses and relevant triggers. WEKA decision trees were used to predict lapses with an accuracy of 0.72 for the group of participants. However, generalization of the group algorithm to each individual was poor, and as such, group- and individual-level data were combined to improve prediction. The findings suggest that 4 weeks of individual data collection is recommended to attain optimal model performance. The predictive algorithm could be utilized to provide in-the-moment interventions to prevent dietary lapses and therefore enhance weight losses. Furthermore, methods in the current study could be translated to other types of health behavior lapses.

  5. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  6. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  8. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  9. Time-lapse video sysem used to study nesting gyrfalcons

    Science.gov (United States)

    Booms, Travis; Fuller, Mark R.

    2003-01-01

    We used solar-powered time-lapse video photography to document nesting Gyrfalcon (Falco rusticolus) food habits in central West Greenland from May to July in 2000 and 2001. We collected 2677.25 h of videotape from three nests, representing 94, 87, and 49% of the nestling period at each nest. The video recorded 921 deliveries of 832 prey items. We placed 95% of the items into prey categories. The image quality was good but did not reveal enough detail to identify most passerines to species. We found no evidence that Gyrfalcons were negatively affected by the video system after the initial camera set-up. The video system experienced some mechanical problems but proved reliable. The system likely can be used to effectively document the food habits and nesting behavior of other birds, especially those delivering large prey to a nest or other frequently used site.

  10. Calibrating Vadose Zone Models with Time-Lapse Gravity Data

    DEFF Research Database (Denmark)

    Christiansen, Lars; Hansen, A. B.; Looms, M. C.

    2009-01-01

    A change in soil water content is a change in mass stored in the subsurface. Given that the mass change is big enough, the change can be measured with a gravity meter. Attempts have been made with varying success over the last decades to use ground-based time-lapse gravity measurements to infer...... hydrogeological parameters. These studies focused on the saturated zone with specific yield as the most prominent target parameter. Any change in storage in the vadose zone has been considered as noise. Our modeling results show a measureable change in gravity from the vadose zone during a forced infiltration...... experiment on 10m by 10m grass land. Simulation studies show a potential for vadose zone model calibration using gravity data in conjunction with other geophysical data, e.g. cross-borehole georadar. We present early field data and calibration results from a forced infiltration experiment conducted over 30...

  11. Combined time-lapse cinematography and immuno-electron microscopy.

    Science.gov (United States)

    Balfour, B M; Goscicka, T; MacKenzie, J L; Gautam, A; Tate, M; Clark, J

    1990-04-01

    A method was developed to record interactions between mobile non-adherent immunocytes by time-lapse cinematography and then to study the same cells by immuno-electron microscopy, using monoclonal antibodies against surface components. For this purpose a modified stage was designed to fit an inverted microscope. The attachment included a device to cool the culture chamber with N2 gas, a micro-injector for monoclonal antibody and immuno-gold treatment, and two pairs of washing needles to change the medium without disturbance. The technique was first employed to study the formation of aggregates around the antigen-presenting cells in cultures containing cells from hyper-immunized animals. Recently peripheral blood cells from normal subjects and patients with immune deficiency syndromes were stimulated with pokeweed mitogen, cluster formation was recorded, and the cells were processed for immuno-electron microscopy.

  12. A Prototype System for Time-Lapse Electrical Resistivity Tomographies

    Directory of Open Access Journals (Sweden)

    Raffaele Luongo

    2012-01-01

    Full Text Available A prototype system for time-lapse acquisition of 2D electrical resistivity tomography (ERT and time domain reflectometry (TDR measurements was installed in a test site affected by a landslide in Basilicata region (southern Italy. The aim of the system is to monitor in real-time the rainwater infiltration into the soil and obtain information about the variation of the water content in the first layers of the subsoil and the possible influence of this variation on landslide activity. A rain gauge placed in the test site gives information on the rainfall intensity and frequency and suggests the acquisition time interval. The installed system and the preliminary results are presented in this paper.

  13. Embryo selection: the role of time-lapse monitoring.

    Science.gov (United States)

    Kovacs, Peter

    2014-12-15

    In vitro fertilization has been available for over 3 decades. Its use is becoming more widespread worldwide, and in the developed world, up to 5% of children have been born following IVF. It is estimated that over 5 million children have been conceived in vitro. In addition to giving hope to infertile couples to have their own family, in vitro fertilization has also introduced risks as well. The risk of multiple gestation and the associated maternal and neonatal morbidity/mortality has increased significantly over the past few decades. While stricter transfer policies have eliminated the majority of the high-order multiples, these changes have not yet had much of an impact on the incidence of twins. A twin pregnancy can be avoided by the transfer of a single embryo only. However, the traditionally used method of morphologic embryo selection is not predictive enough to allow routine single embryo transfer; therefore, new screening tools are needed. Time-lapse embryo monitoring allows continuous, non-invasive embryo observation without the need to remove the embryo from optimal culturing conditions. The extra information on the cleavage pattern, morphologic changes and embryo development dynamics could help us identify embryos with a higher implantation potential. These technologic improvements enable us to objectively select the embryo(s) for transfer based on certain algorithms. In the past 5-6 years, numerous studies have been published that confirmed the safety of time-lapse technology. In addition, various markers have already been identified that are associated with the minimal likelihood of implantation and others that are predictive of blastocyst development, implantation potential, genetic health and pregnancy. Various groups have proposed different algorithms for embryo selection based on mostly retrospective data analysis. However, large prospective trials are needed to study the full benefit of these (and potentially new) algorithms before their

  14. Comparative study to use nano-(Al2O3, CuO, and SiC) with water to enhance photovoltaic thermal PV/T collectors

    International Nuclear Information System (INIS)

    Al-Waeli, Ali H.A.; Chaichan, Miqdam T.; Kazem, Hussein A.; Sopian, K.

    2017-01-01

    Highlights: • Three types of nanoparticles (Al 2 O 3 , CuO and SiC) were added to water which was used as a base fluid. • The resulted nanofluid was used for cooling an indoor PV/T system. • The used nanofluids improved the thermal and electrical efficiencies of the PV/T system. • The stability of nanofluids was examined for an extended period and found to be stable. • SiC nanofluid showed better thermal conductivity and stability compared with Al 2 O 3 and CuO nanofluids. - Abstract: The reduction in efficiency of photovoltaic (PV) units due to increases in cell temperature occurs when a small part of the absorbed solar radiation is converted into electricity and the remaining part is lost as heat. Recently, the addition of a range of nanomaterials with high thermal conductivity to the cooling fluid in PV/T systems has been the subject of much research. In this study, three nanomaterials were added to water as a base fluid with several volume fractions to determine the best concentration and nanoparticle for this application. The PV/T system was setup in an indoor laboratory. Knowing which material has a better effect on the PV unit in particular, and the PV/T unit in general, is important for deciding which nanomaterial is more suitable for the system. The results reveal that nanofluid gives higher thermal conductivity with very little increase in the fluid density and viscosity compared with the base fluid. The studied volume fractions were 0.5, 1, 2, 3, and 4% and the selected nanoparticles were Al 2 O 3 , CuO, and SiC. It was found that silicon carbide nanoparticles have the best stability and the highest thermal conductivity compared to the other two nano-substances. Copper oxide nanofluid has higher thermal conductivity than aluminium oxide but lower stability, although it was found here that this material reliably stable compared to in other studies. The nanofluid reduced the indoor PV/T system temperature and enhanced its generated power.

  15. Booted selective internal radiation therapy (B-SIRT) using 90Y-loaded glass microspheres induces prolonged overall survival for PVT patients

    International Nuclear Information System (INIS)

    Garin, E.; Lenoir, L.; Edeline, J.; Laffont, S.; Mesbah, H.; Poree, P.; Boucher, E.; Rolland, Y.

    2015-01-01

    Full text of publication follows. Goal: evaluation of the response rate and survival of hepatocellular carcinoma PVT patients treated with Therasphere using the boost concept. Material and methods: Therasphere was administered in 40 PVT hepatocellular carcinoma patients (main = 11, lobar = 23, segmental = 6). MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), the healthy injected liver dose (HLD) and the injected liver dose (LD). Response was evaluated at 3 months using EASL criterion. OS was evaluated using Kaplan and Meyer tests. Results: Mean 90 Y-loaded microspheres injected activity was 3.1 ± 1.5 GBq. Mean LD was 143 ± 49 Gy. Median TD was 316 Gy for responding lesions versus 133 Gy for non responding lesion (p<0.0001). With a threshold TD of 205 Gy, MAA-SPECT/CT was predictive of response with a sensibility of 100%, and an overall accuracy of 90% (0FN, 4FP). Knowing the TD and the HLD, 40% of the patients received an intensification of the treatment (increase of the injected activity with the goal to achieve a TD> 205 Gy with a LD > 150 Gy and a HLD<120 Gy) with a good response rate (81%) and without increased liver grade III toxicity (6.2% as against 12.5% in the non boosted patients, ns). 6 patients were put aside, 5 received a lobar hepatectomy. Median OS was 18.2 months [12-27]. It was 4 m [12-27] for patients with a TD < 205 Gy versus 21.5 m [12-28.5] for patients with a TD > 205 Gy. OS was 12 m [3-∞] for patients with main PVT versus 21.5 m [12-28.7] for patients segmental or lobar PVT (ns). Finally Os was 23.2 m for patients with a TD > 205 Gy and a good PVT targeting (n = 34). Conclusion: boosted selective internal radiation therapy using 90 Y-loaded glass microspheres induces prolonged overall survival for PVT patients without increasing liver toxicity. (authors)

  16. The association of positive emotion and first smoking lapse: An ecological momentary assessment study.

    Science.gov (United States)

    Vinci, Christine; Li, Liang; Wu, Cai; Lam, Cho Y; Guo, Lin; Correa-Fernández, Virmarie; Spears, Claire A; Hoover, Diana S; Etcheverry, Paul E; Wetter, David W

    2017-11-01

    Individuals attempting to quit smoking typically have poor success rates, and the majority fail to maintain long-term abstinence. Although a large body of evidence documents the impact of negative affect on reducing abstinence, there is a much smaller body of research on positive emotions, which could be an important mechanism that is associated with successful cessation. As such, this study examined positive emotions in real-time via ecological momentary assessment (EMA) to determine whether discrete positive emotions were uniquely related to 2 cessation milestones: quit day lapse and first lapse. Participants were 391 smokers who received tobacco cessation treatment. EMAs were completed pre- and postquit, and positive emotion was assessed with 3 items (enthusiastic, happy, and relaxed) rated on 5-point Likert scales. Analyses examined the associations of the means and slopes of each emotion on the current day with the likelihood of lapse on the following day. When controlling for relevant covariates, prequit positive emotions were not related to quit day lapse. However, postquit positive emotions were associated with first lapse. Specifically, high levels of happiness and relaxation, as well as increasing levels of enthusiasm, happiness, and relaxation were related to a lower likelihood of next day lapse. These are some of the first real-time, real-world data to demonstrate that distinct positive emotions are associated with a lower risk of lapse during the postquit period among smokers attempting to quit. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  19. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  20. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  1. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  2. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  5. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  6. Time-lapse imaging of neural development: zebrafish lead the way into the fourth dimension.

    Science.gov (United States)

    Rieger, Sandra; Wang, Fang; Sagasti, Alvaro

    2011-07-01

    Time-lapse imaging is often the only way to appreciate fully the many dynamic cell movements critical to neural development. Zebrafish possess many advantages that make them the best vertebrate model organism for live imaging of dynamic development events. This review will discuss technical considerations of time-lapse imaging experiments in zebrafish, describe selected examples of imaging studies in zebrafish that revealed new features or principles of neural development, and consider the promise and challenges of future time-lapse studies of neural development in zebrafish embryos and adults. Copyright © 2011 Wiley-Liss, Inc.

  7. First-order symmetrizable hyperbolic formulations of Einstein's equations including lapse and shift as dynamical fields

    International Nuclear Information System (INIS)

    Alvi, Kashif

    2002-01-01

    First-order hyperbolic systems are promising as a basis for numerical integration of Einstein's equations. In previous work, the lapse and shift have typically not been considered part of the hyperbolic system and have been prescribed independently. This can be expensive computationally, especially if the prescription involves solving elliptic equations. Therefore, including the lapse and shift in the hyperbolic system could be advantageous for numerical work. In this paper, two first-order symmetrizable hyperbolic systems are presented that include the lapse and shift as dynamical fields and have only physical characteristic speeds

  8. Near-surface air temperature lapse rates in Xinjiang, northwestern China

    Science.gov (United States)

    Du, Mingxia; Zhang, Mingjun; Wang, Shengjie; Zhu, Xiaofan; Che, Yanjun

    2018-02-01

    Lapse rates of near-surface (2 m) air temperature are important parameters in hydrologic and climate simulations, especially for the mountainous areas without enough in-situ observations. In Xinjiang, northwestern China, the elevations range from higher than 7000 m to lower than sea level, but the existing long-term meteorological measurements are limited and distributed unevenly. To calculate lapse rates in Xinjiang, the daily data of near-surface air temperature ( T min, T ave, and T max) were measured by automatic weather stations from 2012 to 2014. All the in situ observation stations were gridded into a network of 1.5° (latitude) by 1.5° (longitude), and the spatial distribution and the daily, monthly, seasonal variations of lapse rates for T min, T ave, and T max in Xinjiang are analyzed. The Urumqi River Basin has been considered as a case to study the influence of elevation, aspect, and the wet and dry air conditions to the T min, T ave, and T max lapse rates. Results show that (1) the lapse rates for T min, T ave, and T max vary spatially during the observation period. The spatial diversity of T min lapse rates is larger than that of T ave, and that of T max is the smallest. For each season, T max lapse rates have more negative values than T ave lapse rates which are steeper than T min lapse rates. The weakest spatial diversity usually appears in July throughout a year. (2) The comparison for the three subregions (North, Middle, and South region) exhibits that lapse rates have similar day-to-day and month-to-month characteristics which present shallower values in winter months and steeper values in summer months. The T ave lapse rates in North region are shallower than those in Middle and South region, and the steepest T ave lapse rates of the three regions all appear in April. T min lapse rates are shallower than T max lapse rates. The maximum medians of T min and T max lapse rates for each grid in the three regions all appear in January, whereas the

  9. An experimental investigation of SiC nanofluid as a base-fluid for a photovoltaic thermal PV/T system

    International Nuclear Information System (INIS)

    Al-Waeli, Ali H.A.; Sopian, K.; Chaichan, Miqdam T.; Kazem, Hussein A.; Hasan, Husam Abdulrasool; Al-Shamani, Ali Najah

    2017-01-01

    Highlights: • Nano-SiC-water used as a base fluid for cooling an outdoor PV/T system. • The used nanofluid improved the thermal and electrical efficiencies of the PV/T system. • The stability of nanofluid was examined for an extended period and found to be stable. • The overall effectiveness found to be 88.9% compared to the separate PV system. - Abstract: The thermophysical properties of nanofluid composed of water and SiC nanoparticles without the use of a surfactant as a coolant for a PV/T system was investigated. It was observed that the addition of 3 wt% of these nanoparticles to water caused an increase in the resulting fluid density by up to 0.0082% and an increase of viscosity by up to 1.8%. Moreover, the thermal conductivity was enhanced by up to 8.2% for the tested temperature range of 25 °C–60 °C. The stability of the nanofluid was examined at intervals of three months and it was found that after six months the thermal conductivity reduced by up to 0.003 W/m K, indicating that the solution was stable and suitable for use for long periods. The use of 3 wt% SiC nanofluid increased the electrical efficiency by up to 24.1% compared to the PV system alone, while the thermal efficiency increased by up to 100.19% compared to the use of water for cooling. The final results indicated that the total effectiveness of the PV/T nanofluid system had a higher overall efficiency of about 88.9% compared to the separate PV system.

  10. Experimental determination of PVT data, critical quantities and of the equation of state for sodium up to 2600 K and 500 bar

    International Nuclear Information System (INIS)

    Binder, H.

    1984-01-01

    In the present thesis the PVT-data of fluid sodium are measured up to 2600 K and 500 bar and the vapor pressure curve is determined up to the critical point, which is found to be Tsub(c) = 2485 +- 15 K / Psub(c) = 248 +- 5 bar, rhosub(c) = 0.30 +- 0.05 g/cm 3 . The measured values are used to investigate the attractive forces of sodium theoretically. (BHO)

  11. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  12. P-V-T properties of a polymer liquid crystal subjected to pre-drawing at several temperatures

    International Nuclear Information System (INIS)

    Broza, Georg; Castano, Victor M.; Martinez-Barrera, Gonzalo; Menard, Kevin P.; Simoes, Carla

    2005-01-01

    We have studied the copolymer of poly(ethylene terephthalate) (PET) with 0.6mole fraction of p-hydroxybenzoic acid (PHB). It is a longitudinal polymer liquid crystal (PLC). A number of otherwise identical samples were subjected to drawing to achieve in turn 20%, 40%, 60%, 80% and 100% increase in length. The drawing was performed isothermally at 60, 100 and 140 deg. C. Pressure-volume-temperature (P-V-T) results have been obtained for pressures up to 200Jcm -3 and temperatures up to 150 deg. C or so. Parameters of the Hartmann equation of state have been evaluated. Drawing first results in an increase in specific (and also free) volume, then in a decrease caused by increased orientation of the PLC, and finally in an apparent increase caused by the appearance of voids. The tensile modulus E has been determined for all pre-drawn samples. It reflects the volumetric changes a rebours: the initial increase in specific volume results in lower E values, orientation in E increase, and void formation in a second decrease

  13. Effect of oxygen concentration on human embryo development evaluated by time-lapse monitoring

    DEFF Research Database (Denmark)

    Ingerslev, Hans Jakob; Hindkjær, Johnny Juhl; Kirkegaard, Kirstine

    2012-01-01

    recently demonstrated to occur from first cleavage cycle in mice using time-lapse microscopy, with the largest impact on the pre-compaction stages. However, embryonic development in mice differs in many aspects from human embryonic development. The objective of this retrospective, descriptive study...... was to evaluate the influence of oxygen tension on human pre-implantation development using time-lapse monitoring. Materials and methods: Human embryos were cultured to the blastocyst stage in a time-lapse incubator (EmbryoScope™) in 20% O2 (group 1), 20% O2 for 24 hours followed by culture in 5% O2 (group 2......) or in 5% O2 (group 3). Eligible were patients with age 8 oocytes retrieved. Group 1 consisted of 120 IVF/ICSI embryos from 26 patients recruited to a study conducted to evaluate the safety of the time-lapse incubator by randomising 1:1 embryos from a patient to culture...

  14. Atmospheric Surface Layer Characterization: Preliminary Desert Lapse Rate Study 22-25 August 2000

    National Research Council Canada - National Science Library

    Elliott, Doyle

    2003-01-01

    Results of the August 2000 Desert Lapse Rate (DLR) Experiment are presented. The DLR Experiment was performed to document the night-to-day transition effects on the desert Atmospheric Surface Layer (ASL...

  15. Determinants of return behavior: a comparison of current and lapsed donors.

    Science.gov (United States)

    Germain, Marc; Glynn, Simone A; Schreiber, George B; Gélinas, Stéphanie; King, Melissa; Jones, Mike; Bethel, James; Tu, Yongling

    2007-10-01

    There is a need to identify factors explaining why some people stop donating blood. A random mail survey of first-time (FT) and repeat (RPT) current (donating within 6 months before survey) and lapsed (donating >2 years prior) donors was conducted. The self-administered questionnaire included questions on personal, social, and behavioral characteristics. Among 1280 current and 1672 lapsed donors with valid addresses, the participation rate was 66.8 and 39.2 percent, respectively. In FT donors, the odds of lapsing increased with education (odds ratio [OR], 2.18; 95% confidence interval [CI], 1.34-3.55 for college or higher vs. Grade 12 or less education). Lapsed FT donors were more often asked to donate (OR, 1.89; 95% CI, 1.32-2.70) and had less interest in incentives (p marketing strategies that appeal solely to altruistic values need to be further evaluated for their effectiveness.

  16. Lapse käsi Riigikogu käes / Aivar Jarne

    Index Scriptorium Estoniae

    Jarne, Aivar, 1965-

    2003-01-01

    Rahvastikuprobleemidega toimetulekuks peab kogu lääne kultuuripiirkond ja iga maa omaette mõtlema, kuidas stimuleerida sündimust, suurendada lapse väärtust perekonnas ja vanemate jaoks, tõdeb autor

  17. Network Analysis of Time-Lapse Microscopy Recordings

    Directory of Open Access Journals (Sweden)

    Erik eSmedler

    2014-09-01

    Full Text Available Multicellular organisms rely on intercellular communication to regulate important cellular processes critical to life. To further our understanding of those processes there is a need to scrutinize dynamical signaling events and their functions in both cells and organisms. Here, we report a method and provide MATLAB code that analyzes time-lapse microscopy recordings to identify and characterize network structures within large cell populations, such as interconnected neurons. The approach is demonstrated using intracellular calcium (Ca2+ recordings in neural progenitors and cardiac myocytes, but could be applied to a wide variety of biosensors employed in diverse cell types and organisms. In this method, network structures are analyzed by applying cross-correlation signal processing and graph theory to single-cell recordings. The goal of the analysis is to determine if the single cell activity constitutes a network of interconnected cells and to decipher the properties of this network. The method can be applied in many fields of biology in which biosensors are used to monitor signaling events in living cells. Analyzing intercellular communication in cell ensembles can reveal essential network structures that provide important biological insights.

  18. History matching of time-lapse crosswell data using ensemble kalman filtering

    KAUST Repository

    de Matos Ravanelli, Fabio Miguel

    2015-09-03

    Data from crosswell seismic surveys is processed to provide crosswell time-lapse data to map fluid changes in a reservoir where time-lapse or 4D seismic data is unavailable or unreliable, such as in onshore reservoirs. The resultant processing results provide quantitative information for history matching purposes using a probabilistic approach to take in account uncertainties in the geological model and reduce uncertainties in reservoir production forecasts.

  19. Momentary factors during marijuana use as predictors of lapse during attempted abstinence in young adults.

    Science.gov (United States)

    Shrier, Lydia A; Sarda, Vishnudas; Jonestrask, Cassandra; Harris, Sion Kim

    2018-08-01

    Young adults using marijuana heavily often try multiple times to quit on their own. We sought to identify momentary experiences during marijuana use that could aid in predicting lapse when young adults subsequently attempt abstinence. Young adults (N=34) age 18-25 using marijuana ≥5days/week and planning to quit completed a survey of sociodemographic characteristics, substance use, marijuana expectancies, use motives, perceived social support, and confidence to abstain. They completed ecological momentary assessment (EMA) smartphone reports several times/day for two weeks prior to, then during two weeks of attempted abstinence. Use period EMA reports assessed affect, craving, accessibility, situational permissibility, use, and motivation to abstain. Baseline survey and EMA data were examined in relation to subsequent lapse during attempted abstinence. Nearly 3 in 4 participants (73.5%) reported lapsing during attempted abstinence from marijuana. On bivariate analyses, lower baseline dependence severity score, negative effect expectancies, perceived family support, and confidence to abstain were each associated with lapse. Of the use period EMA variables, greater percent of days with marijuana use, reports of easy accessibility, and reports of situational permissibility were each associated with lapse. Modeled together, negative effect expectancies, perceived family support, confidence to abstain, and situational permissibility during use were highly accurate in predicting lapse during attempted abstinence. Momentary factors may add to conventionally-surveyed characteristics to enhance prediction of lapse during attempted abstinence among young adults with heavy marijuana use. Momentary assessment prior to a quit attempt may thus enable more effective personalized approaches to preventing lapse. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  1. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  2. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  3. Time-lapse seismic attribute analysis for a water-flooded reservoir

    International Nuclear Information System (INIS)

    Jin, Long; Sen, M K; Stoffa, P L; Seif, R K

    2008-01-01

    One of the goals of time-lapse seismic monitoring is the direct detection of the fluid front and two-phase contact area. However, several factors affect the quality of time-lapse seismic difference data and decrease detectability. One of these factors is random noise. In this paper, we propose five different methods aimed at improving the quality and detectability of noisy time-lapse seismic difference data. Common to these methods is the transform of the differences to a domain where the time-lapse signal and random noise are well separated. Our proposed methods include direct Fourier transform based spectral decomposition, bispectra, wavelet transform, singular value decomposition and hybrid methods. We also propose a method that combines multiple time-lapse difference data and gives a final difference which enhances the common part and attenuates the differences of the multiple difference images resulting in a better detectability than the original images. A synthetic time-lapse model is used to demonstrate the feasibility of our proposed methods

  4. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  5. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  17. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  1. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  3. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  5. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  6. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  7. A study of photovoltaic/thermal (PVT)-ground source heat pump hybrid system by using fuzzy logic control

    International Nuclear Information System (INIS)

    Andrew Putrayudha, S.; Kang, Eun Chul; Evgueniy, E.; Libing, Y.; Lee, Euy Joon

    2015-01-01

    Renewable Heat Obligation (RHO) implementation in every country becomes an important issue to utilize more renewable energy sources while reducing the usage of fossil fuel. In 2014, South Korea has a target that every commercial building construction that exceeding 10,000 m 2 has to have on-site new & renewable power generation such as combined heat in the beginning of 2016. Photovoltaic/Thermal (PVT) and Geothermal hybrid systems have been introduced in previous research (E.J. Lee et al.) and it showed a great result from its efficiency and also its power consumption for single and multi-building cases. In this paper, Fuzzy Logic control has been applied to optimize the energy consumption of the system. By comparing it with conventional on–off control, fuzzy logic control system shows a better result in reducing primary energy consumption for both heating and cooling systems annually. Two cases were introduced in this paper, GSHP system and PVT–GSHP system with both on–off and fuzzy logic applied respectively. As a result, it shows that fuzzy logic control consumed 13.3% less energy compared with on–off controller for GSHP system annually and 18.3% less energy compared to on–off controller for PVT–GSHP system annually. - Highlights: • Two renewable systems were designed to produce heating, cooling and electricity. • System optimization by applying Fuzzy Logic in terms of energy saving. • Conventional on–off control system vs advance fuzzy logic control system. • Assumption used based on previous research experience, guidelines.

  8. Novel double-stage high-concentrated solar hybrid photovoltaic/thermal (PV/T) collector with nonimaging optics and GaAs solar cells reflector

    International Nuclear Information System (INIS)

    Abdelhamid, Mahmoud; Widyolar, Bennett K.; Jiang, Lun; Winston, Roland; Yablonovitch, Eli; Scranton, Gregg; Cygan, David; Abbasi, Hamid; Kozlov, Aleksandr

    2016-01-01

    Highlights: • A novel hybrid concentrating photovoltaic thermal (PV/T) collector is developed. • Thermal component achieves 60× concentration using nonimaging optics. • GaAs solar cells used as spectrally selective mirrors for low energy photons. • Thermal efficiencies of 37% at 365 °C and electrical efficiencies of 8% achieved. • Combined electric efficiency reaches 25% of DNI for system cost of $283.10/m"2". - Abstract: A novel double stage high-concentration hybrid solar photovoltaic thermal (PV/T) collector using nonimaging optics and world record thin film single-junction gallium arsenide (GaAs) solar cells has been developed. We present a detailed design and simulation of the system, experimental setup, prototype, system performance, and economic analysis. The system uses a parabolic trough (primary concentrator) to focus sunlight towards a secondary nonimaging compound parabolic concentrator (CPC) to simultaneously generate electricity from single junction GaAs solar cells, as well as high temperature dispatchable heat. This study is novel in that (a) the solar cells inside the vacuum tube act as spectrally selective mirrors for lower energy photons to maximize the system exergy, and (b) secondary concentrator allows the thermal component to reach a concentration ratio ∼60×, which is significantly higher than conventional PV/T concentration ratios. The maximum outlet temperature reached was 365 °C, and on average the thermal efficiency of the experiment was around 37%. The maximum electrical efficiency was around 8%. The total system electricity generation is around 25% of incoming DNI, by assuming the high temperature stream is used to power a steam turbine. The installed system cost per unit of parabolic trough aperture area is $283.10 per m"2.

  9. Etude d'équations d'état en vue de représenter les propriétés PVT et les équilibres liquide-vapeur d'hydrocarbures Equations of State for Representing Pvt Properties and Vapor-Liquid Equilibria of Hydrocarbons

    Directory of Open Access Journals (Sweden)

    Neau E.

    2006-11-01

    Full Text Available Une étude comparative de plusieurs équations d'état issues de la théorie de van der Waals a été effectuée dans le but de sélectionner des modèles capables de calculer les propriétés PVT d'hydrocarbures dans un large domaine de pression et température. 34 hydrocarbures de différentes tailles et structures ont été sélectionnés. Les données expérimentales d'équilibres liquide-vapeur (pressions de vapeur, volumes des liquides et les propriétés PVT de fluides comprimés ont été systématiquement comparées avec des résultats obtenus au moyen de différentes équations d'état. Il est apparu que seules les équations d'état complexes (notamment l'équation COR sont en mesure de représenter correctement les propriétés volumétriques dans un large domaine de température et de pression, le voisinage du point critique inclu. A comparative study of several equations of state (EOS derived from the van der Waals theory was performed. The aim was to select the models able to represent PVT properties of hydrocarbons in large pressure and temperature ranges. 34 hydrocarbons of various sizes and structures were selected. Experimental data of vapor liquid equilibria (vapor pressures and liquid volumes and PVT properties of compressed fluids were systematically compared with results obtained using selected EOS. It was shown that only the complex EOS (especially the COR equation are able to represent volumetric properties in wide temperature and presssure ranges, the critical region included.

  10. Inter- and intra-observer variability of time-lapse annotations

    DEFF Research Database (Denmark)

    Sundvall, Linda; Ingerslev, Hans Jakob; Breth Knudsen, Ulla

    2013-01-01

    . This provides the basis for further investigation of embryo assessment and selection by time-lapse imaging in prospective trials. Study funding/competing interest(s): Research at the Fertility Clinic was funded by an unrestricted grant from Ferring and MSD. The authors have no competing interests to declare.......Study question: How consistent is the time-lapse annotation of dynamic and static morphologic parameters of embryo development, within and between observers? Summary answer: The assessment of dynamic parameters is characterized by almost perfect agreement within and between observers. What is known...... already: The commonly employed method used to assess embryos in IVF treatments is based on static evaluation of morphology in a microscope, but this is limited by substantial intra- and inter-observer variation. Time-lapse imaging has been proposed as a method to refine embryo selection by adding new...

  11. Physical activity adoption to adherence, lapse, and dropout: a self-determination theory perspective.

    Science.gov (United States)

    Kinnafick, Florence-Emilie; Thøgersen-Ntoumani, Cecilie; Duda, Joan L

    2014-05-01

    Grounded in Self-Determination Theory, we aimed to explore and identify key motivational processes involved in the transition from a physically inactive to an active lifestyle, and the processes involved in lapse and dropout behavior within a walking program. We implemented a qualitative, longitudinal case study method, using semistructured interviews and theoretical thematic analyses. Fifteen women were interviewed over 10 months and three profiles were generated: (a) nonadherence, (b) lapse/readoption of physical activity, and (c) adherence. Internalization of walking behavior was key to adherence. Satisfaction of the needs for competence and relatedness were central for participation during exercise at the adoption stages, and autonomy was particularly pertinent in facilitating adherence. Those who lapsed and restarted physical activity experienced feelings of autonomy at the point of readoption. Sources of support were driving forces in the adoption and adherence phases.

  12. How does blastomere removal affect embryonic development? : A time-lapse analysis

    DEFF Research Database (Denmark)

    Kirkegaard, Kirstine; Hindkjær, Johnny Juhl; Ingerslev, Hans Jakob

    of the 6-10 cell embryo. It has been argued that blastomere removal does not affect embryonic development, but few studies have focussed on safety of the procedure. Recently, time-lapse studies on mice have suggested that blastomere removal affects embryonic development. The present study was conducted...... to evaluate the effect of blastomere biopsy on early human embryonic development using time-lapse analysis. Materials and methods: Couples undergoing IVF treatment or PGD were requested permission to include embryos in the project. The diagnosis healthy/diseased was made by analysis of a single blastomere....... For PGD 56 human embryos were biopsied 68 hours after fertilisation, the majority at the eight cell stage. As controls 43 non-biopsied embryos at the 6-8 cell stage were selected. All embryos were cultured until 5 days after fertilisation in a time-lapse incubator (EmbryoScope™). Key events such as time...

  13. Global dynamics of selective attention and its lapses in primary auditory cortex.

    Science.gov (United States)

    Lakatos, Peter; Barczak, Annamaria; Neymotin, Samuel A; McGinnis, Tammy; Ross, Deborah; Javitt, Daniel C; O'Connell, Monica Noelle

    2016-12-01

    Previous research demonstrated that while selectively attending to relevant aspects of the external world, the brain extracts pertinent information by aligning its neuronal oscillations to key time points of stimuli or their sampling by sensory organs. This alignment mechanism is termed oscillatory entrainment. We investigated the global, long-timescale dynamics of this mechanism in the primary auditory cortex of nonhuman primates, and hypothesized that lapses of entrainment would correspond to lapses of attention. By examining electrophysiological and behavioral measures, we observed that besides the lack of entrainment by external stimuli, attentional lapses were also characterized by high-amplitude alpha oscillations, with alpha frequency structuring of neuronal ensemble and single-unit operations. Entrainment and alpha-oscillation-dominated periods were strongly anticorrelated and fluctuated rhythmically at an ultra-slow rate. Our results indicate that these two distinct brain states represent externally versus internally oriented computational resources engaged by large-scale task-positive and task-negative functional networks.

  14. Air and wet bulb temperature lapse rates and their impact on snowmaking in a Pyrenean ski resort

    Science.gov (United States)

    López-Moreno, Juan Ignacio; Navarro-Serrano, F.; Azorín-Molina, C.; Sánchez-Navarrete, P.; Alonso-González, E.; Rico, I.; Morán-Tejeda, E.; Buisan, S.; Revuelto, J.; Pons, M.; Vicente-Serrano, S. M.

    2018-03-01

    A set of 17 air temperature and relative humidity sensors were used to analyze the temporal variability of surface air temperature (Tair), wet bulb temperature (Twb), and daily snowmaking hours (SM, number of hours per day with Twb identical temporal fluctuations. The Twb exhibited average lapse rates that were slightly steeper (- 5.2 °C/km) than those observed for Tair (- 4.9 °C/km). The less steep lapse rates and most thermal inversions were observed in December. Days having less (more) steep Tair and Twb lapse rates were observed under low (high) wind speeds and high (low) relative humidity and air pressure. The temporal dynamics of the SM lapse rates was more complex, as this involved consideration of the average Tair in the ski resort, in addition to the driving factors of the spatio-temporal variability of Twb. Thus, on a number of cold (warm) days, snowmaking was feasible at all elevations at the ski resort, independently of the slopes of the lapse rates. The SM exhibited an average daily lapse rate of 8.2 h/km, with a progressive trend of increase from December to March. Weather types over the Iberian Peninsula tightly control the driving factors of the Tair, Twb, and SM lapse rates (wind speed, relative humidity, and Tair), so the slopes of the lapse rates and the frequency of inversions in relation to elevation for the three variables are very dependent on the occurrence of specific weather types. The less steep lapse rates occurred associated with advections from the southeast, although low lapse rates also occurred during advections from the east and south, and under anticyclonic conditions. The steepest Tair and Twb lapse rates were observed during north and northwest advections, while the steepest rates for SM were observed during days of cyclonic circulation and advections from the northeast.

  15. On the density scaling of pVT data and transport properties for molecular and ionic liquids.

    Science.gov (United States)

    López, Enriqueta R; Pensado, Alfonso S; Fernández, Josefa; Harris, Kenneth R

    2012-06-07

    In this work, a general equation of state (EOS) recently derived by Grzybowski et al. [Phys. Rev. E 83, 041505 (2011)] is applied to 51 molecular and ionic liquids in order to perform density scaling of pVT data employing the scaling exponent γ(EOS). It is found that the scaling is excellent in most cases examined. γ(EOS) values range from 6.1 for ammonia to 13.3 for the ionic liquid [C(4)C(1)im][BF(4)]. These γ(EOS) values are compared with results recently reported by us [E. R. López, A. S. Pensado, M. J. P. Comuñas, A. A. H. Pádua, J. Fernández, and K. R. Harris, J. Chem. Phys. 134, 144507 (2011)] for the scaling exponent γ obtained for several different transport properties, namely, the viscosity, self-diffusion coefficient, and electrical conductivity. For the majority of the compounds examined, γ(EOS) > γ, but for hexane, heptane, octane, cyclopentane, cyclohexane, CCl(4), dimethyl carbonate, m-xylene, and decalin, γ(EOS) liquids. For viscosities and the self-diffusion coefficient-temperature ratio, we have tested the relation linking EOS and dynamic scaling parameters, proposed by Paluch et al. [J. Phys. Chem. Lett. 1, 987-992 (2010)] and Grzybowski et al. [J. Chem. Phys. 133, 161101 (2010); Phys. Rev. E 82, 013501 (2010)], that is, γ = (γ(EOS)/φ) + γ(G), where φ is the stretching parameter of the modified Avramov relation for the density scaling of a transport property, and γ(G) is the Grüneisen constant. This relationship is based on data for structural relaxation times near the glass transition temperature for seven molecular liquids, including glass formers, and a single ionic liquid. For all the compounds examined in our much larger database the ratio (γ(EOS)/φ) is actually higher than γ, with the only exceptions of propylene carbonate and 1-methylnaphthalene. Therefore, it seems the relation proposed by Paluch et al. applies only in certain cases, and is really not generally applicable to liquid transport properties such as

  16. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  17. Automatic segmentation of time-lapse microscopy images depicting a live Dharma embryo.

    Science.gov (United States)

    Zacharia, Eleni; Bondesson, Maria; Riu, Anne; Ducharme, Nicole A; Gustafsson, Jan-Åke; Kakadiaris, Ioannis A

    2011-01-01

    Biological inferences about the toxicity of chemicals reached during experiments on the zebrafish Dharma embryo can be greatly affected by the analysis of the time-lapse microscopy images depicting the embryo. Among the stages of image analysis, automatic and accurate segmentation of the Dharma embryo is the most crucial and challenging. In this paper, an accurate and automatic segmentation approach for the segmentation of the Dharma embryo data obtained by fluorescent time-lapse microscopy is proposed. Experiments performed in four stacks of 3D images over time have shown promising results.

  18. Advances in interpretation of subsurface processes with time-lapse electrical imaging

    Science.gov (United States)

    Singha, Kaminit; Day-Lewis, Frederick D.; Johnson, Tim B.; Slater, Lee D.

    2015-01-01

    Electrical geophysical methods, including electrical resistivity, time-domain induced polarization, and complex resistivity, have become commonly used to image the near subsurface. Here, we outline their utility for time-lapse imaging of hydrological, geochemical, and biogeochemical processes, focusing on new instrumentation, processing, and analysis techniques specific to monitoring. We review data collection procedures, parameters measured, and petrophysical relationships and then outline the state of the science with respect to inversion methodologies, including coupled inversion. We conclude by highlighting recent research focused on innovative applications of time-lapse imaging in hydrology, biology, ecology, and geochemistry, among other areas of interest.

  19. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  20. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. A randomized clinical trial comparing embryo culture in a conventional incubator with a time-lapse incubator

    DEFF Research Database (Denmark)

    Kirkegaard, Kirstine; Hindkjaer, Johnny Juhl; Grøndahl, Marie Louise

    2012-01-01

    Time-lapse monitoring allows for a flexible embryo evaluation and potentially provides new dynamic markers of embryo competence. Before introducing time-lapse monitoring in a clinical setting, the safety of the instrument must be properly documented. Accordingly, the aim of this study...

  2. Application of a linear finite-frequency theory to time-lapse crosswell tomography in ultrasonic and numerical experiments

    NARCIS (Netherlands)

    Spetzler, J.; Sijacic, D.; Wolf, K.H.A.A.

    2007-01-01

    Time-lapse seismic monitoring is the geophysical discipline whereby multiple data sets recorded at the same location but at different times are used to locate and quantify temporal changes in the elastic parameters of the subsurface. We validate a time-lapse monitoring method by crosswell tomography

  3. Modal Logics with Counting

    Science.gov (United States)

    Areces, Carlos; Hoffmann, Guillaume; Denis, Alexandre

    We present a modal language that includes explicit operators to count the number of elements that a model might include in the extension of a formula, and we discuss how this logic has been previously investigated under different guises. We show that the language is related to graded modalities and to hybrid logics. We illustrate a possible application of the language to the treatment of plural objects and queries in natural language. We investigate the expressive power of this logic via bisimulations, discuss the complexity of its satisfiability problem, define a new reasoning task that retrieves the cardinality bound of the extension of a given input formula, and provide an algorithm to solve it.

  4. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  5. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  6. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  7. Aasta keeleteoks tunnistati "Lapse keelelist arengut toetavad mängud" / Mari Klein

    Index Scriptorium Estoniae

    Klein, Mari, 1979-

    2014-01-01

    Emakeelepäeval toimus Kuressaares Saaremaa Ühisgümnaasiumis 2013. aasta parima keeleteo konkursi lõpuüritus, kus tunnustati võitjaid. Peaauhinna võitsid Tallinna Ülikooli eesti keele professor Reili Argus ja Rocca al Mare Kooli eelkooliõpetaja Cattre Hein veebimänguga "Lapse keelelist arengut toetavad mängud"

  8. FY2014 Appropriations Lapse and the Department of Homeland Security: Impact and Legislation

    Science.gov (United States)

    2013-10-24

    and Programs Directorate (NPPD) • Office of Biometric Identity Management • Federal Protective Service Under the Federal Emergency Management...performance of excepted work during the period of the appropriations lapse. After appropriations are enacted, payroll centers will pay all excepted...four hours of work completely dedicated to de- activating a function, such as securing documents, completing payroll , etc.12 Presidential appointees

  9. Time-Lapse and Slow-Motion Tracking of Temperature Changes: Response Time of a Thermometer

    Science.gov (United States)

    Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.

    2017-01-01

    We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure…

  10. Probabilistic 3-D time-lapse inversion of magnetotelluric data: application to an enhanced geothermal system

    Science.gov (United States)

    Rosas-Carbajal, M.; Linde, N.; Peacock, J.; Zyserman, F. I.; Kalscheuer, T.; Thiel, S.

    2015-12-01

    Surface-based monitoring of mass transfer caused by injections and extractions in deep boreholes is crucial to maximize oil, gas and geothermal production. Inductive electromagnetic methods, such as magnetotellurics, are appealing for these applications due to their large penetration depths and sensitivity to changes in fluid conductivity and fracture connectivity. In this work, we propose a 3-D Markov chain Monte Carlo inversion of time-lapse magnetotelluric data to image mass transfer following a saline fluid injection. The inversion estimates the posterior probability density function of the resulting plume, and thereby quantifies model uncertainty. To decrease computation times, we base the parametrization on a reduced Legendre moment decomposition of the plume. A synthetic test shows that our methodology is effective when the electrical resistivity structure prior to the injection is well known. The centre of mass and spread of the plume are well retrieved. We then apply our inversion strategy to an injection experiment in an enhanced geothermal system at Paralana, South Australia, and compare it to a 3-D deterministic time-lapse inversion. The latter retrieves resistivity changes that are more shallow than the actual injection interval, whereas the probabilistic inversion retrieves plumes that are located at the correct depths and oriented in a preferential north-south direction. To explain the time-lapse data, the inversion requires unrealistically large resistivity changes with respect to the base model. We suggest that this is partly explained by unaccounted subsurface heterogeneities in the base model from which time-lapse changes are inferred.

  11. Vähihaiged lapsed jäädvustasid halli haiglaelu piltidele / Madis Filippov

    Index Scriptorium Estoniae

    Filippov, Madis

    2011-01-01

    Tallinna Lastehaigla onkoloogiaosakonnas ravitavate laste fotoringi näitus "Pildid teevad head" Sokos Hotel Viru konverentsikeskuses. Natalja Rogova, Kristen Saar ja Ralf Põllukivi räägivad oma fotodest ja elust haiglas. Samal teemal "Uus pilk elule: vähihaiged lapsed avasid fotonäituse" lk. 1

  12. A Typology of University Ethical Lapses: Types, Levels of Seriousness, and Originating Location

    Science.gov (United States)

    Kelley, Patricia C.; Chang, Pepe Lee

    2007-01-01

    Scandals ranging from National Collegiate Athletic Association (NCAA) violations to falsified research results have fueled criticism of America's universities. Sports violations, research manipulation, gender discrimination, and other ethical lapses affect an entire institution as they have a spillover effect on its reputation. The results of…

  13. CellProfiler Tracer: exploring and validating high-throughput, time-lapse microscopy image data.

    Science.gov (United States)

    Bray, Mark-Anthony; Carpenter, Anne E

    2015-11-04

    Time-lapse analysis of cellular images is an important and growing need in biology. Algorithms for cell tracking are widely available; what researchers have been missing is a single open-source software package to visualize standard tracking output (from software like CellProfiler) in a way that allows convenient assessment of track quality, especially for researchers tuning tracking parameters for high-content time-lapse experiments. This makes quality assessment and algorithm adjustment a substantial challenge, particularly when dealing with hundreds of time-lapse movies collected in a high-throughput manner. We present CellProfiler Tracer, a free and open-source tool that complements the object tracking functionality of the CellProfiler biological image analysis package. Tracer allows multi-parametric morphological data to be visualized on object tracks, providing visualizations that have already been validated within the scientific community for time-lapse experiments, and combining them with simple graph-based measures for highlighting possible tracking artifacts. CellProfiler Tracer is a useful, free tool for inspection and quality control of object tracking data, available from http://www.cellprofiler.org/tracer/.

  14. Lapse of time effects on tax evasion in an agent-based econophysics model

    Science.gov (United States)

    Seibold, Götz; Pickhardt, Michael

    2013-05-01

    We investigate an inhomogeneous Ising model in the context of tax evasion dynamics where different types of agents are parameterized via local temperatures and magnetic fields. In particular, we analyze the impact of lapse of time effects (i.e. backauditing) and endogenously determined penalty rates on tax compliance. Both features contribute to a microfoundation of agent-based econophysics models of tax evasion.

  15. Exploiting the airwave for time-lapse reservoir monitoring with CSEM on land

    NARCIS (Netherlands)

    Wirianto, M.; Mulder, W.A.; Slob, E.C.

    2011-01-01

    In the application of controlled source electromagnetics for reservoir monitoring on land, repeatability errors in the source will mask the time-lapse signal due to hydrocarbon production when recording surface data close to the source. We demonstrate that at larger distances, the airwave will still

  16. Time-Lapse Monitoring of Subsurface Fluid Flow using Parsimonious Seismic Interferometry

    KAUST Repository

    Hanafy, Sherif; Li, Jing; Schuster, Gerard T.

    2017-01-01

    of parsimonious seismic interferometry with the time-lapse mentoring idea with field examples, where we were able to record 30 different data sets within a 2-hour period. The recorded data are then processed to generate 30 snapshots that shows the spread of water

  17. Inter and intra-observer variability of time-lapse annotations

    DEFF Research Database (Denmark)

    Sundvall Germeys, Linda Karin M; Ingerslev, Hans Jakob; Knudsen, Ulla Breth

    . This provides the basis for further investigation of embryo assessment and selection by time-lapse imaging in prospective trials. Study funding/competing interest(s): Research at the Fertility Clinic was funded by an unrestricted grant from Ferring and MSD. The authors have no competing interests to declare....

  18. Latest time-lapse seismic data from Sleipner yield new insights into CO2 plume development

    NARCIS (Netherlands)

    Chadwick, R.A.; Noy, D.; Arts, R.; Eiken, O.

    2009-01-01

    Since its inception in 1996, the CO2 injection operation at Sleipner has been monitored by 3D time-lapse seismic surveys. Striking images of the CO2 plume have been obtained, showing a multi-tier feature of high reflectivity, interpreted as arising from a number of thin layers of CO2 trapped beneath

  19. Time-lapse misorientation maps for the analysis of electron backscatter diffraction data from evolving microstructures

    NARCIS (Netherlands)

    Wheeler, J.; Cross, A.; Drury, M.; Hough, R.M.; Mariani, E.; Piazolo, S.; Prior, D.J.

    2011-01-01

    A “time-lapse misorientation map” is defined here as a map which shows the orientation change at each point in an evolving crystalline microstructure between two different times. Electron backscatter diffraction data from in situ heating experiments can be used to produce such maps, which then

  20. Respiratory problems and anxiety sensitivity in smoking lapse among treatment seeking smokers.

    Science.gov (United States)

    Zvolensky, Michael J; Rodríguez-Cano, Rubén; Paulus, Daniel J; Kotov, Roman; Bromet, Evelyn; Gonzalez, Adam; Manning, Kara; Luft, Benjamin J

    2017-12-01

    The current study examined whether the interaction of lower respiratory symptoms and anxiety sensitivity is related to smoking lapse in the context of smoking cessation. Participants were adult daily smokers (N=60) exposed to the World Trade Center (WTC) disaster who were in a smoking cessation treatment program (75.0% male, 50.6years old [SD=9.2], and current smoking rate was 17.6 cigarettes per day (SD=10.6). Results indicated that the interaction between lower respiratory symptoms and anxiety sensitivity was a significant predictor of greater risk for lapse (i.e., lower survival time; B=0.005, OR=1.01, p=0.039). Follow-up analysis showed that greater respiratory symptoms were a significant predictor of lapse risk among those with high (B=0.116, OR=1.12, p=0.025), but not those with low (B=-0.048, OR=0.95, p=0.322), levels of anxiety sensitivity. The findings from the current study suggest that smokers with greater respiratory symptoms and higher levels of anxiety sensitivity may be associated with early lapse to smoking following smoking cessation treatment. Future work has the potential to inform the development of tailored cessation interventions for smokers who experience varying levels of lower respiratory symptoms and anxiety sensitivity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Developing an EEG based On-line Closed-loop Lapse Detection and Mitigation System

    Directory of Open Access Journals (Sweden)

    Yu-Te eWang

    2014-10-01

    Full Text Available In America, sixty percent of adults reported that they have driven a motor vehicle while feeling drowsy, and at least 15-20% of fatal car accidents are fatigue-related. This study translates previous laboratory-oriented neurophysiological research to design, develop, and test an On-line Closed-loop Lapse Detection and Mitigation (OCLDM System featuring a mobile wireless dry-sensor EEG headgear and a cell-phone based real-time EEG processing platform. Eleven subjects participated in an event-related lane-keeping task, in which they were instructed to manipulate a randomly deviated, fixed-speed cruising car on a 4-lane highway. This was simulated in a 1st person view with an 8-screen and 8-projector immersive virtual-realty environment. When the subjects experienced lapses or failed to respond to events during the experiment, auditory feedback was delivered to rectify the performance decrements. However, the arousing auditory signals were not always effective. The EEG spectra exhibited statistically significant differences between effective and ineffective arousing signals, suggesting that EEG spectra could be used as a countermeasure of the efficacy of arousing signals. In this on-line pilot study, the proposed OCLDM System was able to continuously detect EEG signatures of fatigue, deliver arousing feedback to subjects suffering momentary cognitive lapses, and assess the efficacy of the feedback in near real-time to rectify cognitive lapses. The on-line testing results of the OCLDM System validated the efficacy of the arousing signals in improving subjects' response times to the subsequent lane-departure events. This study may lead to a practical on-line lapse detection and mitigation system in real-world environments.

  2. Developing an EEG-based on-line closed-loop lapse detection and mitigation system.

    Science.gov (United States)

    Wang, Yu-Te; Huang, Kuan-Chih; Wei, Chun-Shu; Huang, Teng-Yi; Ko, Li-Wei; Lin, Chin-Teng; Cheng, Chung-Kuan; Jung, Tzyy-Ping

    2014-01-01

    In America, 60% of adults reported that they have driven a motor vehicle while feeling drowsy, and at least 15-20% of fatal car accidents are fatigue-related. This study translates previous laboratory-oriented neurophysiological research to design, develop, and test an On-line Closed-loop Lapse Detection and Mitigation (OCLDM) System featuring a mobile wireless dry-sensor EEG headgear and a cell-phone based real-time EEG processing platform. Eleven subjects participated in an event-related lane-keeping task, in which they were instructed to manipulate a randomly deviated, fixed-speed cruising car on a 4-lane highway. This was simulated in a 1st person view with an 8-screen and 8-projector immersive virtual-reality environment. When the subjects experienced lapses or failed to respond to events during the experiment, auditory warning was delivered to rectify the performance decrements. However, the arousing auditory signals were not always effective. The EEG spectra exhibited statistically significant differences between effective and ineffective arousing signals, suggesting that EEG spectra could be used as a countermeasure of the efficacy of arousing signals. In this on-line pilot study, the proposed OCLDM System was able to continuously detect EEG signatures of fatigue, deliver arousing warning to subjects suffering momentary cognitive lapses, and assess the efficacy of the warning in near real-time to rectify cognitive lapses. The on-line testing results of the OCLDM System validated the efficacy of the arousing signals in improving subjects' response times to the subsequent lane-departure events. This study may lead to a practical on-line lapse detection and mitigation system in real-world environments.

  3. Let's Make Data Count

    Science.gov (United States)

    Budden, A. E.; Abrams, S.; Chodacki, J.; Cruse, P.; Fenner, M.; Jones, M. B.; Lowenberg, D.; Rueda, L.; Vieglais, D.

    2017-12-01

    The impact of research has traditionally been measured by citations to journal publications and used extensively for evaluation and assessment in academia, but this process misses the impact and reach of data and software as first-class scientific products. For traditional publications, Article-Level Metrics (ALM) capture the multitude of ways in which research is disseminated and used, such as references and citations within social media and other journal articles. Here we present on the extension of usage and citation metrics collection to include other artifacts of research, namely datasets. The Make Data Count (MDC) project will enable measuring the impact of research data in a manner similar to what is currently done with publications. Data-level metrics (DLM) are a multidimensional suite of indicators measuring the broad reach and use of data as legitimate research outputs. By making data metrics openly available for reuse in a number of different ways, the MDC project represents an important first step on the path towards the full integration of data metrics into the research data management ecosystem. By assuring researchers that their contributions to scholarly progress represented by data corpora are acknowledged, data level metrics provide a foundation for streamlining the advancement of knowledge by actively promoting desirable best practices regarding research data management, publication, and sharing.

  4. Frequency of asymptomatic pulmonary emboli (PE) in patients with a proximal profound veinal thrombosis (PVT) of inferior limbs during the FRAXODI study

    International Nuclear Information System (INIS)

    Gauthier, H.; Rosso, J.; Charbonnier, B.; Meignan, M.

    1997-01-01

    FRAXODI, an European multi-center program (n=70), allowed to compare the efficiency of Fraxiparin (20 500 UI AXa/mL) once a day with the conventional treatment by Fraxiparin (10 250 UI AXa/mL) twice a day by sub-cutaneous injection in patients with a PVT of inferior limbs without clinical signs of PE. A pulmonary scintigraphy has been performed at registration in 622 patients (delay ≤ 48 h): a sole perfusion with at least 4 incidences of which 2 were posterior oblique incidences or coupled to a ventilation scintigraphy (Xe-133, Kr-81 or aerosols) in 379 patients. Three diagnostic categories were defined: no PE in case of normal examination or under-segmentary perfusion anomalies (≤ 3); high probability (HP) of PE if at least a defect of normally ventilated segmentary perfusion existed; non-contributing examination in all the other cases. On the ensemble of the group, 367 patients have had at least a defect of segmentary perfusion, 296 patients had two or more. One hundred and forty one patients have had solely defects of sub-segmentary perfusion; 77 patients have had 3 or less then 3. One hundred and fourteen patients have had a normal examination. In the sub-group of ventilation scintigraphy, 235 patients have had at least one defect of segmentary perfusion, 88 patients have had defects of sub-segmentary perfusion and 56 patients have had a normal examination. The diagnosis analysis showed that 42% of patients have had a HP scintigraphy, 30% a non-contributive scintigraphy and the PE could be eliminated in 27% of patients. These results: 1 - demonstrated the extreme frequency of HP aspects of PE in patients afflicted with PVT; 2 - allowed estimating in this patients, as a function of the results of the PIOPED study, the frequency of asymptomatic PE in more then 50%; 3 - allowed recommending in the systematic practice a perfusion scintigraphy in case of PVT without clinical signs of PE providing the over-estimation of secondary PE occurrence during the

  5. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  6. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  7. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  8. A detailed thermal-electrical model of three photovoltaic/thermal (PV/T) hybrid air collectors and photovoltaic (PV) module: Comparative study under Algiers climatic conditions

    International Nuclear Information System (INIS)

    Slimani, Mohamed El Amine; Amirat, Madjid; Kurucz, Ildikó; Bahria, Sofiane; Hamidat, Abderrahmane; Chaouch, Wafa Braham

    2017-01-01

    Highlights: • A detailed thermal and electrical model for PV and PV/T systems has been presented. • The developed numerical model was validated successfully with previously published experimental results. • A comparative study between four solar devices (PV and PV/T systems) was carried out. • The experimental weather conditions of Algiers site are used in the numerical model. • The glazed double-pass photovoltaic/thermal air collector shows the best overall energy efficiency. - Abstract: The thermal photovoltaic hybrid collector is a genuine cogeneration technology; it can produce electricity and heat simultaneously. In this paper, a comparative study is presented between four solar device configurations: photovoltaic module (PV-I), conventional hybrid solar air collector (PV/T-II), glazed hybrid solar air collector (PV/T-III) and glazed double-pass hybrid solar air collector (PV/T-IV). A numerical model is developed and validated through experimental results indicated in the previous literature. The numerical model takes the heat balance equations and different thermal and electrical parameters into account for each configuration included in this study, the energy performances are evaluated with a sample weather data of Algiers site. The numerical results show that the daily average of overall energy efficiency reaches: 29.63%, 51.02%, 69.47% and 74% for the first (PV-I), the second (PV/T-II), the third (PV/T-III) and the fourth (PV/T-IV) configurations respectively. These values are obtained with an air flow of 0.023 kg/s and introducing a sample of experimental weather data collected in Algiers site for a sunny day in summer.

  9. Slope Environmental Lapse Rate (SELR of Temperature in the Monsoon Regime of the Western Himalaya

    Directory of Open Access Journals (Sweden)

    Renoj J. Thayyen

    2018-06-01

    Full Text Available The interplay of moisture, temperature, and precipitation forced through the orographic processes sustain and regulate the Himalayan cryospheric system. However, factors influencing the Slope Environmental Lapse Rate (SELR of temperature along the Himalayan mountain slopes and an appropriate modeling solution remain as a key knowledge gaps. The present study evaulates the SELR variations in the monsoon regime of the western Himalaya and proposes a modeling solution for the valley scale SELR assessment. SELR of selected station pairs in the Sutlej and Beas basins ranging between the elevation of 662–3,130 m a.s.l. and that of Garhwal Himalaya between 770 and 3,820 m a.s.l. were assessed in this study. Results suggest that the moisture–temperature interplay is not only forcing the seasonal variations, but also the elevation-depended variability of the temperature SELR. Temperature lapse rate constrianed to the nival–glacier regime is found to be comparable to the saturated adiabatic lapse rate (SALR and lower than the valley scale SELR. The study also suggests that the bi-modal pattern of the annual temperature lapse rates earlier observed in the Nepal Himalaya is extended up to upper Ganga, Sutlej, and Beas basins in the western Himalaya. This seasonal variability of SELR is found to be closly linked with the seasonal variations in the lifting condensation levels (LCLs over the region. Inter-annual variation in SELR of the nival–glacier regime are found to be significant while that of the valley scale SELR are more stable. We propose a simple preliminary but robust model for deriving the valley scale SELR of monsoon regime modifying the equation governing pseudo adiabatic lapse rate. The SELR modeling solution is achieved by deriving monthly SELR indices using the data of two station pairs in the Sutlej and Beas basins during the 1986–2005 period through K-fold cross validation. The model sucessfully captures seasonal SELR variations

  10. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  11. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  12. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  13. Effect of oxygen concentration on human embryo development evaluated by time-lapse monitoring

    DEFF Research Database (Denmark)

    Ingerslev, Hans Jakob; Hindkjær, Johnny Juhl; Kirkegaard, Kirstine

    2012-01-01

    -points for each cell division and blastocyst stages were registered until 120 hours after oocyte retrieval. Only 2PN embryos completing the first cleavage were evaluated. The groups were compared using one-way ANOVA or Kruskall-Wallis test. Estimates are reported as medians with 95% confidence intervals. Time......Introduction: Data from a number of studies indicate -but not unequivocally- that culture of embryos in 5% O2 compared to 20% O2 improves blastocyst formation in humans and various animal species and may yield better pregnancy rates in IVF. The detrimental effects of atmospheric oxygen were...... was to evaluate the influence of oxygen tension on human pre-implantation development using time-lapse monitoring. Materials and methods: Human embryos were cultured to the blastocyst stage in a time-lapse incubator (EmbryoScope™) in 20% O2 (group 1), 20% O2 for 24 hours followed by culture in 5% O2 (group 2...

  14. Time-Lapse Monitoring of Subsurface Fluid Flow using Parsimonious Seismic Interferometry

    KAUST Repository

    Hanafy, Sherif

    2017-04-21

    A typical small-scale seismic survey (such as 240 shot gathers) takes at least 16 working hours to be completed, which is a major obstacle in case of time-lapse monitoring experiments. This is especially true if the subject that needs to be monitored is rapidly changing. In this work, we will discuss how to decrease the recording time from 16 working hours to less than one hour of recording. Here, the virtual data has the same accuracy as the conventional data. We validate the efficacy of parsimonious seismic interferometry with the time-lapse mentoring idea with field examples, where we were able to record 30 different data sets within a 2-hour period. The recorded data are then processed to generate 30 snapshots that shows the spread of water from the ground surface down to a few meters.

  15. Capturing tissue repair in zebrafish larvae with time-lapse brightfield stereomicroscopy.

    Science.gov (United States)

    Lisse, Thomas S; Brochu, Elizabeth A; Rieger, Sandra

    2015-01-31

    The zebrafish larval tail fin is ideal for studying tissue regeneration due to the simple architecture of the larval fin-fold, which comprises of two layers of skin that enclose undifferentiated mesenchyme, and because the larval tail fin regenerates rapidly within 2-3 days. Using this system, we demonstrate a method for capturing the repair dynamics of the amputated tail fin with time-lapse video brightfield stereomicroscopy. We demonstrate that fin amputation triggers a contraction of the amputation wound and extrusion of cells around the wound margin, leading to their subsequent clearance. Fin regeneration proceeds from proximal to distal direction after a short delay. In addition, developmental growth of the larva can be observed during all stages. The presented method provides an opportunity for observing and analyzing whole tissue-scale behaviors such as fin development and growth in a simple microscope setting, which is easily adaptable to any stereomicroscope with time-lapse capabilities.

  16. Near-surface temperature lapse rates in a mountainous catchment in the Chilean Andes

    Science.gov (United States)

    Ayala; Schauwecker, S.; Pellicciotti, F.; McPhee, J. P.

    2011-12-01

    In mountainous areas, and in the Chilean Andes in particular, the irregular and sparse distribution of recording stations resolves insufficiently the variability of climatic factors such as precipitation, temperature and relative humidity. Assumptions about air temperature variability in space and time have a strong effect on the performance of hydrologic models that represent snow processes such as accumulation and ablation. These processes have large diurnal variations, and assumptions that average over longer time periods (days, weeks or months) may reduce the predictive capacity of these models under different climatic conditions from those for which they were calibrated. They also introduce large uncertainties when such models are used to predict processes with strong subdiurnal variability such as snowmelt dynamics. In many applications and modeling exercises, temperature is assumed to decrease linearly with elevation, using the free-air moist adiabatic lapse rate (MALR: 0.0065°C/m). Little evidence is provided for this assumption, however, and recent studies have shown that use of lapse rates that are uniform in space and constant in time is not appropriate. To explore the validity of this approach, near-surface (2 m) lapse rates were calculated and analyzed at different temporal resolution, based on a new data set of spatially distributed temperature sensors setup in a high elevation catchment of the dry Andes of Central Chile (approx. 33°S). Five minutes temperature data were collected between January 2011 and April 2011 in the Ojos de Agua catchment, using two Automatic Weather Stations (AWSs) and 13 T-loggers (Hobo H8 Pro Temp with external data logger), ranging in altitude from 2230 to 3590 m.s.l.. The entire catchment was snow free during our experiment. We use this unique data set to understand the main controls over temperature variability in time and space, and test whether lapse rates can be used to describe the spatial variations of air

  17. Freeze core sampling to validate time-lapse resistivity monitoring of the hyporheic zone.

    Science.gov (United States)

    Toran, Laura; Hughes, Brian; Nyquist, Jonathan; Ryan, Robert

    2013-01-01

    A freeze core sampler was used to characterize hyporheic zone storage during a stream tracer test. The pore water from the frozen core showed tracer lingered in the hyporheic zone after the tracer had returned to background concentration in collocated well samples. These results confirmed evidence of lingering subsurface tracer seen in time-lapse electrical resistivity tomographs. The pore water exhibited brine exclusion (ion concentrations in ice lower than source water) in a sediment matrix, despite the fast freezing time. Although freeze core sampling provided qualitative evidence of lingering tracer, it proved difficult to quantify tracer concentration because the amount of brine exclusion during freezing could not be accurately determined. Nonetheless, the additional evidence for lingering tracer supports using time-lapse resistivity to detect regions of low fluid mobility within the hyporheic zone that can act as chemically reactive zones of importance in stream health. © 2012, The Author(s). GroundWater © 2012, National Ground Water Association.

  18. Impact of densitized lapse slicings on evolutions of a wobbling black hole

    International Nuclear Information System (INIS)

    Sperhake, Ulrich; Smith, Kenneth L.; Kelly, Bernard; Laguna, Pablo; Shoemaker, Deirdre

    2004-01-01

    We present long-term stable and convergent evolutions of an excised wobbling black hole. Our results clearly demonstrate that the use of a densitized lapse function extends the lifetime of simulations dramatically. We also show the improvement in the stability of single static black holes when an algebraic densitized lapse condition is applied. In addition, we introduce a computationally inexpensive approach for tracking the location of the singularity suitable for mildly distorted black holes. The method is based on investigating the fall-off behavior and asymmetry of appropriate grid variables. This simple tracking method allows one to adjust the location of the excision region to follow the coordinate motion of the singularity

  19. Metoodika lapse emotsionaalse väärkohtlemise hindamiseks institutsionaalses keskkonnas / Triin Edovald

    Index Scriptorium Estoniae

    Edovald, Triin

    2001-01-01

    Uurimusest, mille eesmärgiks oli lapse emotsionaalse väärkohtlemise hindamise metoodika kohandamine lastekodu tingimustele. Uurimus viidi läbi ühes Tartu lastekodus, intervjueerides kuut kasvatajat ja vaadeldes kuue lastekodulapse ja tema usalduskasvataja vahelist suhtlemist ja tegevust eesmärgiga sisse viia võimalikud täpsustused ja muutused emotsionaalse väärkohtlemise hindamise metoodikasse kohandades seda lastekodu tingimustele

  20. Informing hydrological models with ground-based time-lapse relative gravimetry: potential and limitations

    DEFF Research Database (Denmark)

    Bauer-Gottwein, Peter; Christiansen, Lars; Rosbjerg, Dan

    2011-01-01

    parameter uncertainty decreased significantly when TLRG data was included in the inversion. The forced infiltration experiment caused changes in unsaturated zone storage, which were monitored using TLRG and ground-penetrating radar. A numerical unsaturated zone model was subsequently conditioned on both......Coupled hydrogeophysical inversion emerges as an attractive option to improve the calibration and predictive capability of hydrological models. Recently, ground-based time-lapse relative gravity (TLRG) measurements have attracted increasing interest because there is a direct relationship between...

  1. Assessment of Time-Lapse in Visible and Thermal Face Recognition

    Czech Academy of Sciences Publication Activity Database

    Farokhi, Sajad; Shamsuddin, Siti Mariyam; Flusser, Jan; Sheikh, Usman Ullah

    2012-01-01

    Roč. 6, č. 1 (2012), s. 181-186 R&D Projects: GA ČR GAP103/11/1552 Institutional support: RVO:67985556 Keywords : face recognition * moment invariants * Zernike moments Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2012/ZOI/flusser-assessment of time-lapse in visible and thermal face recognition -j.pdf

  2. Seismic time-lapse imaging using Interferometric least-squares migration

    KAUST Repository

    Sinha, Mrinal

    2016-09-06

    One of the problems with 4D surveys is that the environmental conditions change over time so that the experiment is insufficiently repeatable. To mitigate this problem, we propose the use of interferometric least-squares migration (ILSM) to estimate the migration image for the baseline and monitor surveys. Here, a known reflector is used as the reference reflector for ILSM. Results with synthetic and field data show that ILSM can eliminate artifacts caused by non-repeatability in time-lapse surveys.

  3. Unscented Kalman filter assimilation of time-lapse self-potential data for monitoring solute transport

    Science.gov (United States)

    Cui, Yi-an; Liu, Lanbo; Zhu, Xiaoxiong

    2017-08-01

    Monitoring the extent and evolution of contaminant plumes in local and regional groundwater systems from existing landfills is critical in contamination control and remediation. The self-potential survey is an efficient and economical nondestructive geophysical technique that can be used to investigate underground contaminant plumes. Based on the unscented transform, we have built a Kalman filtering cycle to conduct time-lapse data assimilation for monitoring the transport of solute based on the solute transport experiment using a bench-scale physical model. The data assimilation was formed by modeling the evolution based on the random walk model and observation correcting based on the self-potential forward. Thus, monitoring self-potential data can be inverted by the data assimilation technique. As a result, we can reconstruct the dynamic process of the contaminant plume instead of using traditional frame-to-frame static inversion, which may cause inversion artifacts. The data assimilation inversion algorithm was evaluated through noise-added synthetic time-lapse self-potential data. The result of the numerical experiment shows validity, accuracy and tolerance to the noise of the dynamic inversion. To validate the proposed algorithm, we conducted a scaled-down sandbox self-potential observation experiment to generate time-lapse data that closely mimics the real-world contaminant monitoring setup. The results of physical experiments support the idea that the data assimilation method is a potentially useful approach for characterizing the transport of contamination plumes using the unscented Kalman filter (UKF) data assimilation technique applied to field time-lapse self-potential data.

  4. Evaluating four-dimensional time-lapse electrical resistivity tomography for monitoring DNAPL source zone remediation.

    Science.gov (United States)

    Power, Christopher; Gerhard, Jason I; Karaoulis, Marios; Tsourlos, Panagiotis; Giannopoulos, Antonios

    2014-07-01

    Practical, non-invasive tools do not currently exist for mapping the remediation of dense non-aqueous phase liquids (DNAPLs). Electrical resistivity tomography (ERT) exhibits significant potential but has not yet become a practitioner's tool due to challenges in interpreting the survey results at real sites. This study explores the effectiveness of recently developed four-dimensional (4D, i.e., 3D space plus time) time-lapse surface ERT to monitor DNAPL source zone remediation. A laboratory experiment demonstrated the approach for mapping a changing NAPL distribution over time. A recently developed DNAPL-ERT numerical model was then employed to independently simulate the experiment, providing confidence that the DNAPL-ERT model is a reliable tool for simulating real systems. The numerical model was then used to evaluate the potential for this approach at the field scale. Four DNAPL source zones, exhibiting a range of complexity, were initially simulated, followed by modeled time-lapse ERT monitoring of complete DNAPL remediation by enhanced dissolution. 4D ERT inversion provided estimates of the regions of the source zone experiencing mass reduction with time. Results show that 4D time-lapse ERT has significant potential to map both the outline and the center of mass of the evolving treated portion of the source zone to within a few meters in each direction. In addition, the technique can provide a reasonable, albeit conservative, estimate of the DNAPL volume remediated with time: 25% underestimation in the upper 2m and up to 50% underestimation at late time between 2 and 4m depth. The technique is less reliable for identifying cleanup of DNAPL stringers outside the main DNAPL body. Overall, this study demonstrates that 4D time-lapse ERT has potential for mapping where and how quickly DNAPL mass changes in real time during site remediation. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Peeter Kreitzberg : võtame vaestelt lapsed ära! / Peeter Kreitzberg ; interv. Helen Urbanik

    Index Scriptorium Estoniae

    Kreitzberg, Peeter, 1948-2011

    2001-01-01

    Endine haridusminister tuli märtsi keskel konverentsil "Teine võimalus hariduses" välja ettepanekuga, et lastele peaks koolis käimine olema kohustuslik 18. eluaastani, riigi pansionidesse ja internaatidesse tuleks panna need lapsed, kelle pered ei jaksa neid üleval pidada. Autori täiendus 3. mai Eesti Ekspressi kirjade rubriigis (lk. A6) pealkirja all: Pakkusin vanematele võimalust, mitte vaeste laste konfiskeerimist. Autor: Keskerakond. Parlamendisaadik

  6. Time-lapse electrical surveys to locate infiltration zones in weathered hard rock tropical areas

    Science.gov (United States)

    Wubda, M.; Descloitres, M.; Yalo, N.; Ribolzi, O.; Vouillamoz, J. M.; Boukari, M.; Hector, B.; Séguis, L.

    2017-07-01

    In West Africa, infiltration and groundwater recharge processes in hard rock areas are depending on climatic, surface and subsurface conditions, and are poorly documented. Part of the reason is that identification, location and monitoring of these processes is still a challenge. Here, we explore the potential for time-lapse electrical surveys to bring additional information on these processes for two different climate situations: a semi-arid Sahelian site (north of Burkina and a humid Sudanian site (north of Benin), respectively focusing on indirect (localized) and direct (diffuse) recharge processes. The methodology is based on surveys in dry season and rainy season on typical pond or gully using Electrical Resistivity Tomography (ERT) and frequency electromagnetic (FEM) apparent conductivity mapping. The results show that in the Sahelian zone an indirect recharge occurs as expected, but infiltration doesn't takes place at the center of the pond to the aquifer, but occurs laterally in the banks. In Sudanian zone, the ERT survey shows a direct recharge process as expected, but also a complicated behavior of groundwater dilution, as well as the role of hardpans for fast infiltration. These processes are ascertained by groundwater monitoring in adjacent observing wells. At last, FEM time lapse mapping is found to be difficult to quantitatively interpreted due to the non-uniqueness of the model, clearly evidenced comparing FEM result to auger holes monitoring. Finally, we found that time-lapse ERT can be an efficient way to track infiltration processes across ponds and gullies in both climatic conditions, the Sahelian setting providing results easier to interpret, due to significant resistivity contrasts between dry and rain seasons. Both methods can be used for efficient implementation of punctual sensors for complementary studies. However, FEM time-lapse mapping remains difficult to practice without external information that renders this method less attractive for

  7. Probabilistic 3-D time-lapse inversion of magnetotelluric data: Application to an enhanced geothermal system

    Science.gov (United States)

    Rosas-Carbajal, Marina; Linde, Nicolas; Peacock, Jared R.; Zyserman, F. I.; Kalscheuer, Thomas; Thiel, Stephan

    2015-01-01

    Surface-based monitoring of mass transfer caused by injections and extractions in deep boreholes is crucial to maximize oil, gas and geothermal production. Inductive electromagnetic methods, such as magnetotellurics, are appealing for these applications due to their large penetration depths and sensitivity to changes in fluid conductivity and fracture connectivity. In this work, we propose a 3-D Markov chain Monte Carlo inversion of time-lapse magnetotelluric data to image mass transfer following a saline fluid injection. The inversion estimates the posterior probability density function of the resulting plume, and thereby quantifies model uncertainty. To decrease computation times, we base the parametrization on a reduced Legendre moment decomposition of the plume. A synthetic test shows that our methodology is effective when the electrical resistivity structure prior to the injection is well known. The centre of mass and spread of the plume are well retrieved.We then apply our inversion strategy to an injection experiment in an enhanced geothermal system at Paralana, South Australia, and compare it to a 3-D deterministic time-lapse inversion. The latter retrieves resistivity changes that are more shallow than the actual injection interval, whereas the probabilistic inversion retrieves plumes that are located at the correct depths and oriented in a preferential north-south direction. To explain the time-lapse data, the inversion requires unrealistically large resistivity changes with respect to the base model. We suggest that this is partly explained by unaccounted subsurface heterogeneities in the base model from which time-lapse changes are inferred.

  8. Time-lapse seismic - repeatability versus usefulness and 2D versus 3D

    Science.gov (United States)

    Landro, M.

    2017-12-01

    Time-lapse seismic has developed rapidly over the past decades, especially for monitoring of oil and gas reservoirs and subsurface storage of CO2. I will review and discuss some of the critical enabling factors for the commercial success of this technology. It was early realized that how well we are able to repeat our seismic experiment is crucial. However, it is always a question of detectability versus repeatability. For marine seismic, there are several factors limiting the repeatability: Weather conditions, positioning of sources and receivers and so on. I will discuss recent improvements in both acquisition and processing methods over the last decade. It is well known that repeated 3D seismic data is the most accurate tool for reservoir monitoring purposes. However, several examples show that 2D seismic data may be used for monitoring purposes despite lower repeatability. I will use examples from an underground blow out in the North Sea, and repeated 2D seismic lines acquired before and after the Tohoku earthquake in 2011 to illustrate this. A major challenge when using repeated 2D seismic for subsurface monitoring purposes is the lack of 3D calibration points and significantly less amount of data. For marine seismic acquisition, feathering issues and crossline dip effects become more critical compared to 3D seismic acquisition. Furthermore, the uncertainties arising from a non-ideal 2D seismic acquisition are hard to assess, since the 3D subsurface geometry has not been mapped. One way to shed more light on this challenge is to use 3D time lapse seismic modeling testing various crossline dips or geometries. Other ways are to use alternative data sources, such as bathymetry, time lapse gravity or electromagnetic data. The end result for all time-lapse monitoring projects is an interpretation associated with uncertainties, and for the 2D case these uncertainties are often large. The purpose of this talk is to discuss how to reduces and control these

  9. Calixarenes and cations: a time-lapse photography of the big-bang.

    Science.gov (United States)

    Casnati, Alessandro

    2013-08-07

    The outstanding cation complexation properties emerging from the pioneering studies on calixarene ligands during a five-year period in the early 1980s triggered a big-bang burst of publications on such macrocycles that is still lasting at a distance of more than 30 years. A time-lapse photography of this timeframe is proposed which allows the readers to pinpoint the contributions of the different research groups.

  10. Time-lapse misorientation maps for the analysis of electron backscatter diffraction data from evolving microstructures

    International Nuclear Information System (INIS)

    Wheeler, J.; Cross, A.; Drury, M.; Hough, R.M.; Mariani, E.; Piazolo, S.; Prior, D.J.

    2011-01-01

    A 'time-lapse misorientation map' is defined here as a map which shows the orientation change at each point in an evolving crystalline microstructure between two different times. Electron backscatter diffraction data from in situ heating experiments can be used to produce such maps, which then highlight areas of microstructural change and also yield statistics indicative of how far different types of boundary (with different misorientations) have moved.

  11. Lapsed kapsapõldudel mehe eest väljas / Anne Oja

    Index Scriptorium Estoniae

    Oja, Anne, 1970-

    2006-01-01

    Kadarbiku talu peremees Ants Pak kasutab oma põldudel 8-12-aastaste laste tööd. Vt. samas: Vanemad tohivad lapsi tööle panna vaid oma tallu ja pereettevõttesse. Vt. samas Gert D Hankewitz interv. talu peremehe Ants Pakìga: Vanem ise sokutab lapse meile. Kommenteerivad Alar Tamm, Tarmo Kriis, Mailis Reps, Juhan Salum, Janno Järve, Aivo Tamm, Dmitri Jegorov ja Liivi Lents

  12. Seismic time-lapse imaging using Interferometric least-squares migration

    KAUST Repository

    Sinha, Mrinal; Schuster, Gerard T.

    2016-01-01

    One of the problems with 4D surveys is that the environmental conditions change over time so that the experiment is insufficiently repeatable. To mitigate this problem, we propose the use of interferometric least-squares migration (ILSM) to estimate the migration image for the baseline and monitor surveys. Here, a known reflector is used as the reference reflector for ILSM. Results with synthetic and field data show that ILSM can eliminate artifacts caused by non-repeatability in time-lapse surveys.

  13. Inversion of time-domain induced polarization data based on time-lapse concept

    Science.gov (United States)

    Kim, Bitnarae; Nam, Myung Jin; Kim, Hee Joon

    2018-05-01

    Induced polarization (IP) surveys, measuring overvoltage phenomena of the medium, are widely and increasingly performed not only for exploration of mineral resources but also for engineering applications. Among several IP survey methods such as time-domain, frequency-domain and spectral IP surveys, this study introduces a noble inversion method for time-domain IP data to recover the chargeability structure of target medium. The inversion method employs the concept of 4D inversion of time-lapse resistivity data sets, considering the fact that measured voltage in time-domain IP survey is distorted by IP effects to increase from the instantaneous voltage measured at the moment the source current injection starts. Even though the increase is saturated very fast, we can consider the saturated and instantaneous voltages as a time-lapse data set. The 4D inversion method is one of the most powerful method for inverting time-lapse resistivity data sets. Using the developed IP inversion algorithm, we invert not only synthetic but also field IP data to show the effectiveness of the proposed method by comparing the recovered chargeability models with those from linear inversion that was used for the inversion of the field data in a previous study. Numerical results confirm that the proposed inversion method generates reliable chargeability models even though the anomalous bodies have large IP effects.

  14. An ecological momentary intervention for smoking cessation: The associations of just-in-time, tailored messages with lapse risk factors.

    Science.gov (United States)

    Hébert, Emily T; Stevens, Elise M; Frank, Summer G; Kendzor, Darla E; Wetter, David W; Zvolensky, Michael J; Buckner, Julia D; Businelle, Michael S

    2018-03-01

    Smartphone apps can provide real-time, tailored interventions for smoking cessation. The current study examines the effectiveness of a smartphone-based smoking cessation application that assessed risk for imminent smoking lapse multiple times per day and provided messages tailored to current smoking lapse risk and specific lapse triggers. Participants (N=59) recruited from a safety-net hospital smoking cessation clinic completed phone-based ecological momentary assessments (EMAs) 5 times/day for 3 consecutive weeks (1week pre-quit, 2weeks post-quit). Risk for smoking lapse was estimated in real-time using a novel weighted lapse risk estimator. With each EMA, participants received messages tailored to current level of risk for imminent smoking lapse and self-reported presence of smoking urge, stress, cigarette availability, and motivation to quit. Generalized linear mixed model analyses determined whether messages tailored to specific lapse risk factors were associated with greater reductions in these triggers than messages not tailored to specific triggers. Overall, messages tailored to smoking urge, cigarette availability, or stress corresponded with greater reductions in those triggers than messages that were not tailored to specific triggers (p's=0.02 to <0.001). Although messages tailored to stress were associated with greater reductions in stress than messages not tailored to stress, the association was non-significant (p=0.892) when only moments of high stress were included in the analysis. Mobile technology can be used to conduct real-time smoking lapse risk assessment and provide tailored treatment content. Findings provide initial evidence that tailored content may impact users' urge to smoke, stress, and cigarette availability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  16. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  17. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  18. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  19. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  20. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  1. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse.

    Science.gov (United States)

    Martínez-Granados, Luis; Serrano, María; González-Utor, Antonio; Ortíz, Nereyda; Badajoz, Vicente; Olaya, Enrique; Prados, Nicolás; Boada, Montse; Castilla, Jose A

    2017-01-01

    The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost

  2. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse.

    Directory of Open Access Journals (Sweden)

    Luis Martínez-Granados

    Full Text Available The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation, to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei; the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there

  3. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  4. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  5. Rock Slope Monitoring from 4D Time-Lapse Structure from Motion Analysis

    Science.gov (United States)

    Kromer, Ryan; Abellan, Antonio; Chyz, Alex; Hutchinson, Jean

    2017-04-01

    Structure from Motion (SfM) photogrammetry has become an important tool for studying earth surface processes because of its flexibility, ease of use, low cost and its capability of producing high quality 3-D surface models. A major benefit of SfM is that model accuracy is fit for purpose and surveys can be designed to meet a large range of spatial and temporal scales. In the Earth sciences, research in time-lapse SfM photogrammetry or videogrammetry is an area that is difficult to undertake due to complexities in acquiring, processing and managing large 4D datasets and represents an area with significant advancement potential (Eltner et al. 2016). In this study, we investigate the potential of 4D time-lapse SfM to monitor unstable rock slopes. We tested an array of statically mounted cameras collecting time-lapse photos of a limestone rock slope located along a highway in Canada. Our setup consisted of 8 DSLR cameras with 50 mm prime lenses spaced 2-3 m apart at a distance of 10 m from the slope. The portion of the rock slope monitored was 20 m wide and 6 m high. We collected data in four phases, each having 50 photographs taken simultaneously by each camera. The first phase of photographs was taken of the stable slope. In each successive phase, we gradually moved small, discrete blocks within the rock slope by 5-15 mm, simulating pre-failure deformation of rockfall. During the last phase we also removed discrete rock blocks, simulating rockfall. We used Agisoft Photoscan's 4D processing functionality and timeline tools to create 3D point clouds from the time-lapse photographs. These tools have the benefit of attaining better accuracy photo alignments as a greater number of photos are used. For change detection, we used the 4D filtering and calibration technique proposed by Kromer et al. (2015), which takes advantage of high degrees of spatial and temporal point redundancy to decrease measurement uncertainty. Preliminary results show that it is possible to attain

  6. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  7. Time-lapse refraction seismic tomography for the detection of ground ice degradation

    Directory of Open Access Journals (Sweden)

    C. Hilbich

    2010-07-01

    Full Text Available The ice content of the subsurface is a major factor controlling the natural hazard potential of permafrost degradation in alpine terrain. Monitoring of changes in ice content is therefore similarly important as temperature monitoring in mountain permafrost. Although electrical resistivity tomography monitoring (ERTM proved to be a valuable tool for the observation of ice degradation, results are often ambiguous or contaminated by inversion artefacts. In theory, the sensitivity of P-wave velocity of seismic waves to phase changes between unfrozen water and ice is similar to the sensitivity of electric resistivity. Provided that the general conditions (lithology, stratigraphy, state of weathering, pore space remain unchanged over the observation period, temporal changes in the observed travel times of repeated seismic measurements should indicate changes in the ice and water content within the pores and fractures of the subsurface material. In this paper, a time-lapse refraction seismic tomography (TLST approach is applied as an independent method to ERTM at two test sites in the Swiss Alps. The approach was tested and validated based on a the comparison of time-lapse seismograms and analysis of reproducibility of the seismic signal, b the analysis of time-lapse travel time curves with respect to shifts in travel times and changes in P-wave velocities, and c the comparison of inverted tomograms including the quantification of velocity changes. Results show a high potential of the TLST approach concerning the detection of altered subsurface conditions caused by freezing and thawing processes. For velocity changes on the order of 3000 m/s even an unambiguous identification of significant ice loss is possible.

  8. Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation.

    Science.gov (United States)

    Johnson, Timothy C; Versteeg, Roelof J; Day-Lewis, Frederick D; Major, William; Lane, John W

    2015-01-01

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial

  9. A state-space Bayesian framework for estimating biogeochemical transformations using time-lapse geophysical data

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.; Hubbard, S.; Williams, K.; Pride, S.; Li, L.; Steefel, C.; Slater, L.

    2009-04-15

    We develop a state-space Bayesian framework to combine time-lapse geophysical data with other types of information for quantitative estimation of biogeochemical parameters during bioremediation. We consider characteristics of end-products of biogeochemical transformations as state vectors, which evolve under constraints of local environments through evolution equations, and consider time-lapse geophysical data as available observations, which could be linked to the state vectors through petrophysical models. We estimate the state vectors and their associated unknown parameters over time using Markov chain Monte Carlo sampling methods. To demonstrate the use of the state-space approach, we apply it to complex resistivity data collected during laboratory column biostimulation experiments that were poised to precipitate iron and zinc sulfides during sulfate reduction. We develop a petrophysical model based on sphere-shaped cells to link the sulfide precipitate properties to the time-lapse geophysical attributes and estimate volume fraction of the sulfide precipitates, fraction of the dispersed, sulfide-encrusted cells, mean radius of the aggregated clusters, and permeability over the course of the experiments. Results of the case study suggest that the developed state-space approach permits the use of geophysical datasets for providing quantitative estimates of end-product characteristics and hydrological feedbacks associated with biogeochemical transformations. Although tested here on laboratory column experiment datasets, the developed framework provides the foundation needed for quantitative field-scale estimation of biogeochemical parameters over space and time using direct, but often sparse wellbore data with indirect, but more spatially extensive geophysical datasets.

  10. The contribution of attentional lapses to individual differences in visual working memory capacity.

    Science.gov (United States)

    Adam, Kirsten C S; Mance, Irida; Fukuda, Keisuke; Vogel, Edward K

    2015-08-01

    Attentional control and working memory capacity are important cognitive abilities that substantially vary between individuals. Although much is known about how attentional control and working memory capacity relate to each other and to constructs like fluid intelligence, little is known about how trial-by-trial fluctuations in attentional engagement impact trial-by-trial working memory performance. Here, we employ a novel whole-report memory task that allowed us to distinguish between varying levels of attentional engagement in humans performing a working memory task. By characterizing low-performance trials, we can distinguish between models in which working memory performance failures are caused by either (1) complete lapses of attention or (2) variations in attentional control. We found that performance failures increase with set-size and strongly predict working memory capacity. Performance variability was best modeled by an attentional control model of attention, not a lapse model. We examined neural signatures of performance failures by measuring EEG activity while participants performed the whole-report task. The number of items correctly recalled in the memory task was predicted by frontal theta power, with decreased frontal theta power associated with poor performance on the task. In addition, we found that poor performance was not explained by failures of sensory encoding; the P1/N1 response and ocular artifact rates were equivalent for high- and low-performance trials. In all, we propose that attentional lapses alone cannot explain individual differences in working memory performance. Instead, we find that graded fluctuations in attentional control better explain the trial-by-trial differences in working memory that we observe.

  11. Time-lapse electrical geophysical monitoring of amendment-based biostimulation

    Science.gov (United States)

    Johnson, Timothy C.; Versteeg, Roelof J.; Day-Lewis, Frederick D.; Major, William; Lane, John W.

    2015-01-01

    Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation.Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation.In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial

  12. Time-lapse 3D imaging of calcite precipitation in a microporous column

    Science.gov (United States)

    Godinho, Jose R. A.; Withers, Philip J.

    2018-02-01

    Time-lapse X-ray computed tomography is used to image the evolution of calcite precipitation during flow through microporous quartz over the course of 400 h. The growth rate decreases by more than seven times, which is linked to the clogging of flow paths that restricts flow to some regions of the column. Fewer precipitates are observed as a function of column depth, which is found to be related to a differential nucleation density along the sample. A higher nucleation density closer to the inlet implies more crystal volume increase per unit of time without affecting the rate if normalized to the surface area of crystals. Our overall growth rates measured in porous media are orders of magnitude slower than growth rates derived from traditional precipitation experiments on free surfaces. Based on our time-lapse results we hypothesize a scenario where the evolving distribution of precipitates within a pore structure during precipitation progressively modifies the local transport through the pores. Within less permeable regions the saturation index may be lower than along the main flow paths. Therefore, the reactive crystal surfaces within those regions grow at a slower rate than that expected from the bulk fluid composition. Since the amount of reactive surface area within these less permeable regions increases over time, the overall growth rate decreases without a necessary significant change of the bulk fluid composition along more permeable flow paths. In conclusion, the overall growth rates in an evolving porous media expected from bulk fluid compositions alone can be overestimated due to the development of stagnant sub-regions where the reactive surface area is bath by a solution with lower saturation index. In this context we highlight the value of time-lapse 3D studies for understanding the dynamics of mineral precipitation in porous media.

  13. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  14. Comparative study of initial growth stage in PVT growth of AlN on SiC and on native AlN substrates

    Energy Technology Data Exchange (ETDEWEB)

    Epelbaum, B.M.; Heimann, P.; Bickermann, M.; Winnacker, A. [Department of Materials Science 6, University of Erlangen-Nuernberg, Martensstr. 7, 91058 Erlangen (Germany)

    2005-05-01

    The main issue in homoepitaxial growth of aluminum nitride (AlN) on native seed substrates appears to be aluminum oxynitride poisoning of seed surface leading to polycrystalline growth at 1750-1850 C. This is well below the lowest growth temperature appropriate for physical vapor transport (PVT) of bulk AlN, which is about 2150 C. Contrary, heteroepitaxial growth of AlN on SiC is relatively easy to achieve because of natural formation of a thin molten layer on the seed surface and VLS growth of AlN via the molten buffer layer. The most critical issue of AlN growth on SiC is cracking of the grown layer upon cooling as a result of different thermal expansion. Optimization of seeded growth process can be achieved by proper choice of SiC seed orientation and by use of ultra-pure starting material. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Soil Contamination, Advanced integrated characterisation and time-lapse Monitoring, SoilCAM project highlights

    Science.gov (United States)

    French, H. K.; Van Der Zee, S. E.; Wehrer, M.; Godio, A.; Pedersen, L. B.; Tsocano, G.

    2013-12-01

    The SoilCAM project (2008- 2012, EU-FP7-212663) aimed at improving methods for monitoring subsurace contaminant distribution and biodegradation. Two test sites were chosen, Oslo airport Gardermoen, Norway where de-icing agents infiltrate the soil during snowmelt and the Trecate site in Italy where an inland crude oil spill occurred in 1994. A number of geophysical investigation techniques were combined with soil and water sampling techniques. Data obtained from time-lapse measurements were further analysed by numerical modelling of flow and transport at different scales in order to characterise transport processes in the unsaturated and saturated zones. Laboratory experiments provided physical and biogeochemical data for model parameterisation and to select remediation methods. The geophysical techniques were used to map geological heterogeneities and to conduct time-lapse measurements of processes in the unsaturated zone. Both cross borehole and surface electrodes were used for electrical resistivity and induced polarisation surveys. Results showed clear indications of areas highly affected by de-icing chemicals along the runway at Oslo airport. The time lapse measurements along the runway at the airport showed infiltration patterns during snowmelt and were used to validate 2D unsaturated flow and transport simulations using SUTRA. The simulations illustrate the effect of layering geological structures and membranes, buried parallel to the runway, on the flow pattern. Complex interaction between bio-geo-chemical processes in a 1D vertical profile along the runway were described with the ORCHESTRA model. Smaller scale field site measurements revealed increase of iron and manganese during degradation of de-icing chemicals. At the Trecate site a combination of georadar, electrical resistivity and radio magneto telluric provided a broad outline of the geology down to 50 m. Anomalies in the Induced polarisation and electrical resistivity data from the cross borehole

  16. Imaging the developing heart: synchronized time-lapse microscopy during developmental changes

    Science.gov (United States)

    Nelson, Carl J.; Buckley, Charlotte; Mullins, John J.; Denvir, Martin A.; Taylor, Jonathan

    2018-02-01

    How do you use imaging to analyse the development of the heart, which not only changes shape but also undergoes constant, high-speed, quasi-periodic changes? We have integrated ideas from prospective and retrospective optical gating to capture long-term, phase-locked developmental time-lapse videos. In this paper we demonstrate the success of this approach over a key developmental time period: heart looping, where large changes in heart shape prevent previous prospective gating approaches from capturing phase- locked videos. We use the comparison with other approaches to in vivo heart imaging to highlight the importance of collecting the most appropriate data for the biological question.

  17. A software solution for recording circadian oscillator features in time-lapse live cell microscopy

    Directory of Open Access Journals (Sweden)

    Salmon Patrick

    2010-07-01

    Full Text Available Abstract Background Fluorescent and bioluminescent time-lapse microscopy approaches have been successfully used to investigate molecular mechanisms underlying the mammalian circadian oscillator at the single cell level. However, most of the available software and common methods based on intensity-threshold segmentation and frame-to-frame tracking are not applicable in these experiments. This is due to cell movement and dramatic changes in the fluorescent/bioluminescent reporter protein during the circadian cycle, with the lowest expression level very close to the background intensity. At present, the standard approach to analyze data sets obtained from time lapse microscopy is either manual tracking or application of generic image-processing software/dedicated tracking software. To our knowledge, these existing software solutions for manual and automatic tracking have strong limitations in tracking individual cells if their plane shifts. Results In an attempt to improve existing methodology of time-lapse tracking of a large number of moving cells, we have developed a semi-automatic software package. It extracts the trajectory of the cells by tracking theirs displacements, makes the delineation of cell nucleus or whole cell, and finally yields measurements of various features, like reporter protein expression level or cell displacement. As an example, we present here single cell circadian pattern and motility analysis of NIH3T3 mouse fibroblasts expressing a fluorescent circadian reporter protein. Using Circadian Gene Express plugin, we performed fast and nonbiased analysis of large fluorescent time lapse microscopy datasets. Conclusions Our software solution, Circadian Gene Express (CGE, is easy to use and allows precise and semi-automatic tracking of moving cells over longer period of time. In spite of significant circadian variations in protein expression with extremely low expression levels at the valley phase, CGE allows accurate and

  18. 3-D time-lapse electrical resistivity monitoring of injected CO2 in a shallow aquifer

    DEFF Research Database (Denmark)

    Doetsch, Joseph A. J.A.; Auken, Esben; Christiansen, Anders Vest C A.V.C.

    2013-01-01

    and 10 m and monitored its migration using 320 surface electrodes on a 126 m × 20 m grid. A fully automated acquisition system continuously collected data and uploaded it into an online database. The large amount of data allows for time-series analysis for data quality and noise estimation. A baseline...... inversion reveals the geology at the site consisting of aeolian sands near the surface and glacial sands below 5 m depth. Time-lapse inversions clearly image the dissolved CO2 plume with decreased electrical resistivity values. We can follow the CO2 plume as it spreads and moves with the groundwater...

  19. Segmentation Method of Time-Lapse Microscopy Images with the Focus on Biocompatibility Assessment

    Czech Academy of Sciences Publication Activity Database

    Soukup, Jindřich; Císař, P.; Šroubek, Filip

    2016-01-01

    Roč. 22, č. 3 (2016), s. 497-506 ISSN 1431-9276 R&D Projects: GA ČR GA13-29225S Grant - others:GA MŠk(CZ) LO1205; GA UK(CZ) 914813/2013; GA UK(CZ) SVV-2016-260332; CENAKVA(CZ) CZ.1.05/2.1.00/01.0024 Institutional support: RVO:67985556 Keywords : phase contrast microscopy * segmentation * biocompatibility assessment * time-lapse * cytotoxicity testing Subject RIV: JD - Computer Applications, Robotics Impact factor: 1.891, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/soukupj-0460642.pdf

  20. Time-lapse reveals that osteoclasts can move across the bone surface while resorbing

    DEFF Research Database (Denmark)

    Søe, Kent; Delaissé, Jean-Marie

    2017-01-01

    , clear real-time observations are still lacking. Herein, we used specific markers and time-lapse to monitor live the spatiotemporal generation of resorption events by osteoclasts cultured on bone slices. In accordance with the current view, we found alternating episodes of resorption and migration...... trenches. Compared to pit events, trench events show properties enabling higher aggressiveness: long duration (days), high erosion speed (two times faster) and long-distance erosion (several 100 µm). Simultaneous resorption and migration reflect a unique situation where epithelial/secretory and mesenchymal....../migratory characteristics are integrated into just one cell phenotype, and deserves attention in future research....

  1. A software solution for recording circadian oscillator features in time-lapse live cell microscopy.

    Science.gov (United States)

    Sage, Daniel; Unser, Michael; Salmon, Patrick; Dibner, Charna

    2010-07-06

    Fluorescent and bioluminescent time-lapse microscopy approaches have been successfully used to investigate molecular mechanisms underlying the mammalian circadian oscillator at the single cell level. However, most of the available software and common methods based on intensity-threshold segmentation and frame-to-frame tracking are not applicable in these experiments. This is due to cell movement and dramatic changes in the fluorescent/bioluminescent reporter protein during the circadian cycle, with the lowest expression level very close to the background intensity. At present, the standard approach to analyze data sets obtained from time lapse microscopy is either manual tracking or application of generic image-processing software/dedicated tracking software. To our knowledge, these existing software solutions for manual and automatic tracking have strong limitations in tracking individual cells if their plane shifts. In an attempt to improve existing methodology of time-lapse tracking of a large number of moving cells, we have developed a semi-automatic software package. It extracts the trajectory of the cells by tracking theirs displacements, makes the delineation of cell nucleus or whole cell, and finally yields measurements of various features, like reporter protein expression level or cell displacement. As an example, we present here single cell circadian pattern and motility analysis of NIH3T3 mouse fibroblasts expressing a fluorescent circadian reporter protein. Using Circadian Gene Express plugin, we performed fast and nonbiased analysis of large fluorescent time lapse microscopy datasets. Our software solution, Circadian Gene Express (CGE), is easy to use and allows precise and semi-automatic tracking of moving cells over longer period of time. In spite of significant circadian variations in protein expression with extremely low expression levels at the valley phase, CGE allows accurate and efficient recording of large number of cell parameters, including

  2. Lapse in embryo transfer training does not negatively affect clinical pregnancy rates for reproductive endocrinology and infertility fellows.

    Science.gov (United States)

    Kresowik, Jessica; Sparks, Amy; Duran, Eyup H; Shah, Divya K

    2015-03-01

    To compare rates of clinical pregnancy (CPR) and live birth (LBR) following embryo transfer (ET) performed by reproductive endocrinology and infertility (REI) fellows before and after a prolonged lapse in clinical training due to an 18-month research rotation. Retrospective cohort study. Not applicable. All women undergoing in vitro fertilization (IVF) and IVF-intracytoplasmic sperm injection (ICSI) cycles with ET performed by REI fellows from August 2003 to July 2012. Eighteen-month lapse in clinical training of REI fellows. CPR and LBR before and after the lapse in clinical training were calculated and compared per fellow and as a composite group. Alternating logistic regression models were used to calculate the odds of clinical pregnancy and live birth following transfers performed before and after the lapse in training. Unadjusted odds of clinical pregnancy and live birth were similar between the two time periods both for individual fellows and for the composite group. Alternate logistic regression analysis revealed no significant difference in CPR (odds ratio [OR] 0.94, 95% confidence interval [CI] 0.83-1.07) or LBR (OR 1.05, 95% CI 0.94-1.18) after the lapse in training compared with before. A research rotation is common in REI fellowship training programs. This prolonged departure from clinical training does not appear to negatively affect pregnancy outcome following fellow ET. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  4. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  5. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  6. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  7. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  8. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  9. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  10. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  11. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  12. Attention lapses in children with spina bifida and hydrocephalus and children with attention-deficit/hyperactivity disorder.

    Science.gov (United States)

    De la Torre, Gabriel G; Martin, Alba; Cervantes, Elizabeth; Guil, Rocio; Mestre, Jose M

    2017-08-01

    Attentional lapses are usually defined as temporary and often brief shifts of attention away from some primary task to unrelated internal information processing. This study addressed the incidence of attention lapses and differences in attentional functioning in 30 children with attention-deficit/hyperactivity disorder (ADHD), 26 healthy children, and 29 children with spina bifida myelomeningocele and hydrocephalus (SBH). Assessments were conducted using computerized tonic and phasic attention tests, the Symbol Digit Modalities Test (SDMT), and the Trail Making Test Form B (TMT-B). The group with SBH differed from normal controls on cognitive measures of attention and executive functions. The ADHD group obtained lower scores than the SBH group and healthy children. ANOVA results showed that there was an effect of shunt revisions and shunt-related infections on neuropsychological performance. Lapses of attention together with reaction time may thus represent important factors for the understanding of cognitive deficits in SBH.

  13. Attention failures versus misplaced diligence: separating attention lapses from speed-accuracy trade-offs.

    Science.gov (United States)

    Seli, Paul; Cheyne, James Allan; Smilek, Daniel

    2012-03-01

    In two studies of a GO-NOGO task assessing sustained attention, we examined the effects of (1) altering speed-accuracy trade-offs through instructions (emphasizing both speed and accuracy or accuracy only) and (2) auditory alerts distributed throughout the task. Instructions emphasizing accuracy reduced errors and changed the distribution of GO trial RTs. Additionally, correlations between errors and increasing RTs produced a U-function; excessively fast and slow RTs accounted for much of the variance of errors. Contrary to previous reports, alerts increased errors and RT variability. The results suggest that (1) standard instructions for sustained attention tasks, emphasizing speed and accuracy equally, produce errors arising from attempts to conform to the misleading requirement for speed, which become conflated with attention-lapse produced errors and (2) auditory alerts have complex, and sometimes deleterious, effects on attention. We argue that instructions emphasizing accuracy provide a more precise assessment of attention lapses in sustained attention tasks. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Time lapse imaging: is it time to incorporate this technology into routine clinical practice?

    Science.gov (United States)

    Bhide, Priya; Maheshwari, Abha; Cutting, Rachel; Seenan, Susan; Patel, Anita; Khan, Khalid; Homburg, Roy

    2017-06-01

    Time-lapse imaging (TLI) systems for embryo incubation, assessment and selection are a novel technology available to in vitro fertilization (IVF) clinics. However, there is uncertainty about their clinical and cost-effectiveness and insufficient good quality evidence to warrant their routine use. Despite this, enthusiastic commercial marketing and slipping clinical equipoise have led to the widespread hasty introduction of this technology into practice, often at a considerable expense to the patient. We have reviewed the published literature and aim to summarize the strengths, weaknesses, opportunities and threats of these systems. These specialized incubators provide undisturbed embryo culture conditions and, by almost continuous monitoring of embryo development, generate morphokinetic parameters to aid embryo selection. They are thus hypothesized to improve outcomes following IVF. Although literature reports improved reproductive outcomes, these outcomes are largely surrogate and there is a paucity of studies reporting live births. The use of time lapse systems may reduce early pregnancy loss, increase elective single embryo transfers and limit multiple pregnancies through better embryo selection. However, the quality of the studies and hence the evidence so far, is low to moderate quality. We recommend further research producing robust high-quality evidence for and against the use of these systems.

  15. Attentional Lapses in Attention-Deficit/Hyperactivity Disorder: Blank Rather Than Wandering Thoughts.

    Science.gov (United States)

    Van den Driessche, Charlotte; Bastian, Mikaël; Peyre, Hugo; Stordeur, Coline; Acquaviva, Éric; Bahadori, Sara; Delorme, Richard; Sackur, Jérôme

    2017-10-01

    People with attention-deficit/hyperactivity disorder (ADHD) have difficulties sustaining their attention on external tasks. Such attentional lapses have often been characterized as the simple opposite of external sustained attention, but the different types of attentional lapses, and the subjective experiences to which they correspond, remain unspecified. In this study, we showed that unmedicated children (ages 6-12) with ADHD, when probed during a standard go/no-go task, reported more mind blanking (a mental state characterized by the absence of reportable content) than did control participants. This increase in mind blanking happened at the expense of both focused and wandering thoughts. We also found that methylphenidate reverted the level of mind blanking to baseline (i.e., the level of mind blanking reported by control children without ADHD). However, this restoration led to mind wandering more than to focused attention. In a second experiment, we extended these findings to adults who had subclinical ADHD. These results suggest that executive functions impaired in ADHD are required not only to sustain external attention but also to maintain an internal train of thought.

  16. Time-lapse nanoscopy of friction in the non-Amontons and non-Coulomb regime.

    Science.gov (United States)

    Ishida, Tadashi; Sato, Takaaki; Ishikawa, Takahiro; Oguma, Masatsugu; Itamura, Noriaki; Goda, Keisuke; Sasaki, Naruo; Fujita, Hiroyuki

    2015-03-11

    Originally discovered by Leonard da Vinci in the 15th century, the force of friction is directly proportional to the applied load (known as Amontons' first law of friction). Furthermore, kinetic friction is independent of the sliding speed (known as Coulomb's law of friction). These empirical laws break down at high normal pressure (due to plastic deformation) and low sliding speed (in the transition regime between static friction and kinetic friction). An important example of this phenomenon is friction between the asperities of tectonic plates on the Earth. Despite its significance, little is known about the detailed mechanism of friction in this regime due to the lack of experimental methods. Here we demonstrate in situ time-lapse nanoscopy of friction between asperities sliding at ultralow speed (∼0.01 nm/s) under high normal pressure (∼GPa). This is made possible by compressing and rubbing a pair of nanometer-scale crystalline silicon anvils with electrostatic microactuators and monitoring its dynamical evolution with a transmission electron microscope. Our analysis of the time-lapse movie indicates that superplastic behavior is induced by decrystallization, plastic deformation, and atomic diffusion at the asperity-asperity interface. The results hold great promise for a better understanding of quasi-static friction under high pressure for geoscience, materials science, and nanotechnology.

  17. Tracking tracer breakthrough in the hyporheic zone using time‐lapse DC resistivity, Crabby Creek, Pennsylvania

    Science.gov (United States)

    Nyquist, Jonathan E.; Toran, Laura; Fang, Allison C.; Ryan, Robert J.; Rosenberry, Donald O.

    2010-01-01

    Characterization of the hyporheic zone is of critical importance for understanding stream ecology, contaminant transport, and groundwater‐surface water interaction. A salt water tracer test was used to probe the hyporheic zone of a recently re‐engineered portion of Crabby Creek, a stream located near Philadelphia, PA. The tracer solution was tracked through a 13.5 meter segment of the stream using both a network of 25 wells sampled every 5–15 minutes and time‐lapse electrical resistivity tomographs collected every 11 minutes for six hours, with additional tomographs collected every 100 minutes for an additional 16 hours. The comparison of tracer monitoring methods is of keen interest because tracer tests are one of the few techniques available for characterizing this dynamic zone, and logistically it is far easier to collect resistivity tomographs than to install and monitor a dense network of wells. Our results show that resistivity monitoring captured the essential shape of the breakthrough curve and may indicate portions of the stream where the tracer lingered in the hyporheic zone. Time‐lapse resistivity measurements, however, represent time averages over the period required to collect a tomographic data set, and spatial averages over a volume larger than captured by a well sample. Smoothing by the resistivity data inversion algorithm further blurs the resulting tomograph; consequently resistivity monitoring underestimates the degree of fine‐scale heterogeneity in the hyporheic zone.

  18. Time-Lapse Electrical Resistivity Investigations for Imaging the Grouting Injection in Shallow Subsurface Cavities

    Directory of Open Access Journals (Sweden)

    Muhammad Farooq

    2014-01-01

    Full Text Available The highway of Yongweol-ri, Muan-gun, south-western part of the South Korean Peninsula, is underlain by the abandoned of subsurface cavities, which were discovered in 2005. These cavities lie at shallow depths with the range of 5∼15 meters below the ground surface. Numerous subsidence events have repeatedly occurred in the past few years, damaging infrastructure and highway. As a result of continuing subsidence issues, the Korean Institute of Geosciences and Mineral Resources (KIGAM was requested by local administration to resolve the issue. The KIGAM used geophysical methods to delineate subsurface cavities and improve more refined understanding of the cavities network in the study area. Cement based grouting has been widely employed in the construction industry to reinforce subsurface ground. In this research work, time-lapse electrical resistivity surveys were accomplished to monitor the grouting injection in the subsurface cavities beneath the highway, which have provided a quasi-real-time monitoring for modifying the subsurface cavities related to ground reinforcement, which would be difficult with direct methods. The results obtained from time-lapse electrical resistivity technique have satisfactory imaged the grouting injection experiment in the subsurface cavities beneath the highway. Furthermore, the borehole camera confirmed the presence of grouting material in the subsurface cavities, and hence this procedure increases the mechanical resistance of subsurface cavities below the highway.

  19. Using a time lapse microgravity model for mapping seawater intrusion around Semarang

    Energy Technology Data Exchange (ETDEWEB)

    Supriyadi,, E-mail: supriyadi@mail.unnes.ac.id; Khumaedi [Physics Department, Semarang State University (UNNES), D7 Building 2nd Floor FMIPA Sekaran Gunungpati (Indonesia); Yusuf, M. [Badan Meteologi Klimatologi Goefisika (BMKG), Jl.Angkasa I No.2 Kemayoran Jakarta Pusat (Indonesia); Agung, W. [Physics Department, Diponegoro University (UNDIP), Jl. Prof. Soedharto, Tembalang, Semarang (Indonesia)

    2016-03-11

    A modeling of time-lapse microgravity anomaly due to sea water intrusion has been conducted. It used field data of aquifer cross section, aquifer thickness and lithology of research area. Those data were then processed using Grav3D and Surfer. Modeling results indicated that the intrusion of sea water resulting in a time-lapse microgravity anomalies of 0.12 to 0.18 mGal, at soil layer density of 0.15 g/cm{sup 3} to 0.3 g/cm{sup 3} and at depth of 30 to 100 m. These imply that the areas experiencing seawater intrusion were Tanjung Mas, SPBE Bandarharjo, Brass, Old Market Boom and Johar as the microgravity measured there were in the range of 0.12 to 0.18 mGal and the density contrast were at 0.15 g/cm{sup 3} to 0.28 g/cm{sup 3}. Areas that experienced fluid reduction were Puri Anjasmoro, Kenconowungu and Puspowarno with microgravity changes from -0.06 mGal to -0.18 mGal.

  20. Stochastic modeling of oligodendrocyte generation in cell culture: model validation with time-lapse data

    Directory of Open Access Journals (Sweden)

    Noble Mark

    2006-05-01

    Full Text Available Abstract Background The purpose of this paper is two-fold. The first objective is to validate the assumptions behind a stochastic model developed earlier by these authors to describe oligodendrocyte generation in cell culture. The second is to generate time-lapse data that may help biomathematicians to build stochastic models of cell proliferation and differentiation under other experimental scenarios. Results Using time-lapse video recording it is possible to follow the individual evolutions of different cells within each clone. This experimental technique is very laborious and cannot replace model-based quantitative inference from clonal data. However, it is unrivalled in validating the structure of a stochastic model intended to describe cell proliferation and differentiation at the clonal level. In this paper, such data are reported and analyzed for oligodendrocyte precursor cells cultured in vitro. Conclusion The results strongly support the validity of the most basic assumptions underpinning the previously proposed model of oligodendrocyte development in cell culture. However, there are some discrepancies; the most important is that the contribution of progenitor cell death to cell kinetics in this experimental system has been underestimated.

  1. Time-lapse crystallography snapshots of a double-strand break repair polymerase in action.

    Science.gov (United States)

    Jamsen, Joonas A; Beard, William A; Pedersen, Lars C; Shock, David D; Moon, Andrea F; Krahn, Juno M; Bebenek, Katarzyna; Kunkel, Thomas A; Wilson, Samuel H

    2017-08-15

    DNA polymerase (pol) μ is a DNA-dependent polymerase that incorporates nucleotides during gap-filling synthesis in the non-homologous end-joining pathway of double-strand break repair. Here we report time-lapse X-ray crystallography snapshots of catalytic events during gap-filling DNA synthesis by pol μ. Unique catalytic intermediates and active site conformational changes that underlie catalysis are uncovered, and a transient third (product) metal ion is observed in the product state. The product manganese coordinates phosphate oxygens of the inserted nucleotide and PP i . The product metal is not observed during DNA synthesis in the presence of magnesium. Kinetic analyses indicate that manganese increases the rate constant for deoxynucleoside 5'-triphosphate insertion compared to magnesium. The likely product stabilization role of the manganese product metal in pol μ is discussed. These observations provide insight on structural attributes of this X-family double-strand break repair polymerase that impact its biological function in genome maintenance.DNA polymerase (pol) μ functions in DNA double-strand break repair. Here the authors use time-lapse X-ray crystallography to capture the states of pol µ during the conversion from pre-catalytic to product complex and observe a third transiently bound metal ion in the product state.

  2. The time-lapse AVO difference inversion for changes in reservoir parameters

    Science.gov (United States)

    Longxiao, Zhi; Hanming, Gu; Yan, Li

    2016-12-01

    The result of conventional time-lapse seismic processing is the difference between the amplitude and the post-stack seismic data. Although stack processing can improve the signal-to-noise ratio (SNR) of seismic data, it also causes a considerable loss of important information about the amplitude changes and only gives the qualitative interpretation. To predict the changes in reservoir fluid more precisely and accurately, we also need the quantitative information of the reservoir. To achieve this aim, we develop the method of time-lapse AVO (amplitude versus offset) difference inversion. For the inversion of reservoir changes in elastic parameters, we apply the Gardner equation as the constraint and convert the three-parameter inversion of elastic parameter changes into a two-parameter inversion to make the inversion more stable. For the inversion of variations in the reservoir parameters, we infer the relation between the difference of the reflection coefficient and variations in the reservoir parameters, and then invert reservoir parameter changes directly. The results of the theoretical modeling computation and practical application show that our method can estimate the relative variations in reservoir density, P-wave and S-wave velocity, calculate reservoir changes in water saturation and effective pressure accurately, and then provide reference for the rational exploitation of the reservoir.

  3. Time lapse seismic observations and effects of reservoir compressibility at Teal South oil field

    Science.gov (United States)

    Islam, Nayyer

    One of the original ocean-bottom time-lapse seismic studies was performed at the Teal South oil field in the Gulf of Mexico during the late 1990's. This work reexamines some aspects of previous work using modern analysis techniques to provide improved quantitative interpretations. Using three-dimensional volume visualization of legacy data and the two phases of post-production time-lapse data, I provide additional insight into the fluid migration pathways and the pressure communication between different reservoirs, separated by faults. This work supports a conclusion from previous studies that production from one reservoir caused regional pressure decline that in turn resulted in liberation of gas from multiple surrounding unproduced reservoirs. I also provide an explanation for unusual time-lapse changes in amplitude-versus-offset (AVO) data related to the compaction of the producing reservoir which, in turn, changed an isotropic medium to an anisotropic medium. In the first part of this work, I examine regional changes in seismic response due to the production of oil and gas from one reservoir. The previous studies primarily used two post-production ocean-bottom surveys (Phase I and Phase II), and not the legacy streamer data, due to the unavailability of legacy prestack data and very different acquisition parameters. In order to incorporate the legacy data in the present study, all three post-stack data sets were cross-equalized and examined using instantaneous amplitude and energy volumes. This approach appears quite effective and helps to suppress changes unrelated to production while emphasizing those large-amplitude changes that are related to production in this noisy (by current standards) suite of data. I examine the multiple data sets first by using the instantaneous amplitude and energy attributes, and then also examine specific apparent time-lapse changes through direct comparisons of seismic traces. In so doing, I identify time-delays that, when

  4. Analysis of compaction initiation in human embryos by using time-lapse cinematography.

    Science.gov (United States)

    Iwata, Kyoko; Yumoto, Keitaro; Sugishima, Minako; Mizoguchi, Chizuru; Kai, Yoshiteru; Iba, Yumiko; Mio, Yasuyuki

    2014-04-01

    To analyze the initiation of compaction in human embryos in vitro by using time-lapse cinematography (TLC), with the goal of determining the precise timing of compaction and clarifying the morphological changes underlying the compaction process. One hundred and fifteen embryos donated by couples with no further need for embryo-transfer were used in this study. Donated embryos were thawed and processed, and then their morphological behavior during the initiation of compaction was dynamically observed via time-lapse cinematography (TLC) for 5 days. Although the initiation of compaction occurred throughout the period from the 4-cell to 16-cell stage, 99 (86.1 %) embryos initiated compaction at the 8-cell stage or later, with initiation at the 8-cell stage being most frequent (22.6 %). Of these 99 embryos, 49.5 % developed into good-quality blastocysts. In contrast, of the 16 (13.9 %) embryos that initiated compaction prior to the 8-cell stage, only 18.8 % developed into good-quality blastocysts. Embryos that initiated compaction before the 8-cell stage showed significantly higher numbers of multinucleated blastomeres, due to asynchronism in nuclear division at the third mitotic division resulting from cytokinetic failure. The initiation of compaction primarily occurs at the third mitotic division or later in human embryos. Embryos that initiate compaction before the 8-cell stage are usually associated with aberrant embryonic development (i.e., cytokinetic failure accompanied by karyokinesis).

  5. Possible mechanism of polyspermy block in human oocytes observed by time-lapse cinematography.

    Science.gov (United States)

    Mio, Yasuyuki; Iwata, Kyoko; Yumoto, Keitaro; Kai, Yoshiteru; Sargant, Haruka C; Mizoguchi, Chizuru; Ueda, Minako; Tsuchie, Yuka; Imajo, Akifumi; Iba, Yumiko; Nishikori, Kyoko

    2012-09-01

    To analyze the fertilization process related to polyspermy block in human oocytes using an in vitro culturing system for time-lapse cinematography. We had 122 oocytes donated for this study from couples that provided informed consent. We recorded human oocytes at 2,000 to 2,800 frames every 10 s during the fertilization process and thereafter every 2 min using a new in vitro culture system originally developed by the authors for time-lapse cinematography. We displayed 30 frames per second for analysis of the polyspermy block during fertilization. Three oocytes showed the leading and following sperm within the zona pellucida in the same microscopic field. The dynamic images obtained during the fertilization process using this new system revealed that once a leading sperm penetrated the zona pellucida and attached to the oocyte membrane, a following sperm was arrested from further penetration into the zona pellucida within 10 s. The present results strongly suggest the existence of a novel mechanism of polyspermy block that takes place at the zona pellucida immediately after fertilization. These findings are clearly different from previous mechanisms describing polyspermy block as the oocyte membrane block to sperm penetration and the zona reaction. The finding presented herein thus represents a novel discovery about the highly complicated polyspermy block mechanism occurring in human oocytes.

  6. Time Lapse Electrical Resistivity to Connect Evapotranspiration and Groundwater Fluxes in the Critical Zone

    Science.gov (United States)

    Jarvis, S. K.; Harmon, R. E.; Barnard, H. R.; Randall, J.; Singha, K.

    2017-12-01

    The critical zone (CZ)—an open system extending from canopy top to the base of groundwater—is a highly dynamic and heterogeneous environment. In forested terrain, trees make up a large component of the CZ. This work aims to quantify the connection between vegetation and subsurface water storage at a hillslope scale within a forested watershed in the H.J. Andrews Experimental Forest, Oregon. To identify the mechanism(s) controlling the connection at the hillslope scale, we observe patterns in electrical conductivity using 2D-time lapse-DC resistivity. To compare inversions through time a representative error model was determined using L-curve criterion. Inverted data show high spatial variability in ground electrical conductivity and variation at both diel and seasonal timescales. These changes are most pronounced in areas corresponding to dense vegetation. The diel pattern in electrical conductivity is also observed in monitored sap flow sensors, water-level gauges, tensiometers, and sediment thermal probes. To quantify the temporal connection between these data over the course of the growing season a cross correlation analysis was conducted. Preliminary data show that over the course of the growing season transpiration becomes decoupled from both groundwater and soil moisture. Further decomposition of the inverted time lapse data will highlight spatial variability in electrical conductivity providing insight into the where, when, and how(s) of tree-modified subsurface storage.

  7. Bayesian Markov chain Monte Carlo Inversion of Time-Lapse Geophysical Data To Characterize the Vadose Zone

    DEFF Research Database (Denmark)

    Scholer, Marie; Irving, James; Zibar, Majken Caroline Looms

    Geophysical methods have the potential to provide valuable information on hydrological properties in the unsaturated zone. In particular, time-lapse geophysical data, when coupled with a hydrological model and inverted stochastically, may allow for the effective estimation of subsurface hydraulic...... parameters and their corresponding uncertainties. In this study, we use a Bayesian Markov-chain-Monte-Carlo (MCMC) inversion approach to investigate how much information regarding vadose zone hydraulic properties can be retrieved from time-lapse crosshole GPR data collected at the Arrenaes field site...

  8. Time-lapse seismic waveform modelling and attribute analysis using hydromechanical models for a deep reservoir undergoing depletion

    Science.gov (United States)

    He, Y.-X.; Angus, D. A.; Blanchard, T. D.; Wang, G.-L.; Yuan, S.-Y.; Garcia, A.

    2016-04-01

    Extraction of fluids from subsurface reservoirs induces changes in pore pressure, leading not only to geomechanical changes, but also perturbations in seismic velocities and hence observable seismic attributes. Time-lapse seismic analysis can be used to estimate changes in subsurface hydromechanical properties and thus act as a monitoring tool for geological reservoirs. The ability to observe and quantify changes in fluid, stress and strain using seismic techniques has important implications for monitoring risk not only for petroleum applications but also for geological storage of CO2 and nuclear waste scenarios. In this paper, we integrate hydromechanical simulation results with rock physics models and full-waveform seismic modelling to assess time-lapse seismic attribute resolution for dynamic reservoir characterization and hydromechanical model calibration. The time-lapse seismic simulations use a dynamic elastic reservoir model based on a North Sea deep reservoir undergoing large pressure changes. The time-lapse seismic traveltime shifts and time strains calculated from the modelled and processed synthetic data sets (i.e. pre-stack and post-stack data) are in a reasonable agreement with the true earth models, indicating the feasibility of using 1-D strain rock physics transform and time-lapse seismic processing methodology. Estimated vertical traveltime shifts for the overburden and the majority of the reservoir are within ±1 ms of the true earth model values, indicating that the time-lapse technique is sufficiently accurate for predicting overburden velocity changes and hence geomechanical effects. Characterization of deeper structure below the overburden becomes less accurate, where more advanced time-lapse seismic processing and migration is needed to handle the complex geometry and strong lateral induced velocity changes. Nevertheless, both migrated full-offset pre-stack and near-offset post-stack data image the general features of both the overburden and

  9. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  10. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  11. Card counting in continuous time

    OpenAIRE

    Andersson, Patrik

    2012-01-01

    We consider the problem of finding an optimal betting strategy for a house-banked casino card game that is played for several coups before reshuffling. The sampling without replacement makes it possible to take advantage of the changes in the expected value as the deck is depleted, making large bets when the game is advantageous. Using such a strategy, which is easy to implement, is known as card counting. We consider the case of a large number of decks, making an approximat...

  12. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  13. A Hybrid Model through the Fusion of Type-2 Fuzzy Logic Systems and Sensitivity-Based Linear Learning Method for Modeling PVT Properties of Crude Oil Systems

    Directory of Open Access Journals (Sweden)

    Ali Selamat

    2012-01-01

    Full Text Available Sensitivity-based linear learning method (SBLLM has recently been used as a predictive tool due to its unique characteristics and performance, particularly its high stability and consistency during predictions. However, the generalisation capability of SBLLM is sometimes limited depending on the nature of the dataset, particularly on whether uncertainty is present in the dataset or not. Since it made use of sensitivity analysis in relation to the data sets used, it is surely very prone to being affected by the nature of the dataset. In order to reduce the effects of uncertainties in SBLLM prediction and improve its generalisation ability, this paper proposes a hybrid system through the unique combination of type-2 fuzzy logic systems (type-2 FLSs and SBLLM; thereafter the hybrid system was used to model PVT properties of crude oil systems. Type-2 FLS has been choosen in order to better handle uncertainties existing in datasets beyond the capability of type-1 fuzzy logic systems. In the proposed hybrid, the type-2 FLS is used to handle uncertainties in reservoir data so that the cleaned data from type-2 FLS is then passed to the SBLLM for training and then final prediction using testing dataset follows. Comparative studies have been carried out to compare the performance of the newly proposed T2-SBLLM hybrid system with each of the constituent type-2 FLS and SBLLM. Empirical results from simulation show that the proposed T2-SBLLM hybrid system has greatly improved upon the performance of SBLLM, while also maintaining a better performance above that of the type-2 FLS.

  14. Investigation of heat transfer and fluid flow in transitional regime inside a channel with staggered plates heated by radiation for PV/T system

    International Nuclear Information System (INIS)

    Ali, Ahmed Hamza H.; Ahmed, Mahmoud; Abdel-Gaied, S.M.

    2013-01-01

    This study investigates experimentally and theoretically the effects of operating and configuration parameters on convection heat transfer process and fluid flow characteristics for air flowing in transitional regimes through parallel plate channels with staggered plates segments heated by radiant heat flux. This configuration is to be utilized in air heater solar collectors and/or in a combined photovoltaic and air heater solar collector systems (PV/T). The operating parameters tested were Reynolds number (Re) values ranging from 2580 to 4650 with a combination of incident radiation heat flux (q inc ) values of 400, 700, and 1000 W/m 2 , respectively. The experimental results show that the local Nusselt number (Nu x ) is not unique function of the axial distance, in addition, a linear relationship between Re and apparent friction factor (f) was observed. Moreover, the model results show that combination of Re values in the laminar flow regime with proper selection of both plate's length and thickness can lead to enhancement in the heat transfer from the plate segments to the air stream. This is due to self-oscillatory flow mixer in wake zone behind each plate segment. Consequently, this will lead to avoid the need of more pumping power for the case of the flow falling within the transitional regime in the channel. - Highlights: • The local heat transfer coefficient is not unique function in the axial distance. • A linear relationship between Reynolds number and apparent friction factor is observed for Re > 3500. • The plate thickness is the dominant parameter affects both values of the heat transfer and friction factor. • Shorter plates' length, at any plate thickness, leads to periodic boundary layers interruption mechanisms

  15. Optimization of a Time-Lapse Gravity Network for Carbon Sequestration

    Science.gov (United States)

    Appriou, D.; Strickland, C. E.; Ruprecht Yonkofski, C. M.

    2017-12-01

    The objective of this study is to evaluate what could be a comprehensive and optimal state of the art gravity monitoring network that would meet the UIC class VI regulation and insure that 90% of the CO2 injected remain underground. Time-lapse gravity surveys have a long history of effective applications of monitoring temporal density changes in the subsurface. For decades, gravity measurements have been used for a wide range of applications. The interest of time-lapse gravity surveys for monitoring carbon sequestration sites started recently. The success of their deployment in such sites depends upon a combination of favorable conditions, such as the reservoir geometry, depth, thickness, density change over time induced by the CO2 injection and the location of the instrument. In most cases, the density changes induced by the CO2 plume in the subsurface are not detectable from the surface but the use of borehole gravimeters can provide excellent results. In the framework of the National Assessment and Risk Partnership (NRAP) funded by the Department of Energy, the evaluation of the effectiveness of the gravity monitoring of a CO2 storage site has been assessed using multiple synthetic scenarios implemented on a community model developed for the Kimberlina site (e.g., fault leakage scenarios, borehole leakage). The Kimberlina carbon sequestration project was a pilot project located in southern San Joaquin Valley, California, aimed to safely inject 250,000 t CO2/yr for four years. Although the project was cancelled in 2012, the site characterization efforts resulted in the development of a geologic model. In this study, we present the results of the time-lapse gravity monitoring applied on different multiphase flow and reactive transport models developed by Lawrence Berkeley National Laboratory (i.e., no leakage, permeable fault zone, wellbore leakage). Our monitoring approach considers an ideal network, consisting of multiple vertical and horizontal instrumented

  16. Active and passive electrical and seismic time-lapse monitoring of earthen embankments

    Science.gov (United States)

    Rittgers, Justin Bradley

    In this dissertation, I present research involving the application of active and passive geophysical data collection, data assimilation, and inverse modeling for the purpose of earthen embankment infrastructure assessment. Throughout the dissertation, I identify several data characteristics, and several challenges intrinsic to characterization and imaging of earthen embankments and anomalous seepage phenomena, from both a static and time-lapse geophysical monitoring perspective. I begin with the presentation of a field study conducted on a seeping earthen dam, involving static and independent inversions of active tomography data sets, and self-potential modeling of fluid flow within a confined aquifer. Additionally, I present results of active and passive time-lapse geophysical monitoring conducted during two meso-scale laboratory experiments involving the failure and self-healing of embankment filter materials via induced vertical cracking. Identified data signatures and trends, as well as 4D inversion results, are discussed as an underlying motivation for conducting subsequent research. Next, I present a new 4D acoustic emissions source localization algorithm that is applied to passive seismic monitoring data collected during a full-scale embankment failure test. Acoustic emissions localization results are then used to help spatially constrain 4D inversion of collocated self-potential monitoring data. I then turn to time-lapse joint inversion of active tomographic data sets applied to the characterization and monitoring of earthen embankments. Here, I develop a new technique for applying spatiotemporally varying structural joint inversion constraints. The new technique, referred to as Automatic Joint Constraints (AJC), is first demonstrated on a synthetic 2D joint model space, and is then applied to real geophysical monitoring data sets collected during a full-scale earthen embankment piping-failure test. Finally, I discuss some non-technical issues related to

  17. Minds “At Attention”: Mindfulness Training Curbs Attentional Lapses in Military Cohorts

    Science.gov (United States)

    Jha, Amishi P.; Morrison, Alexandra B.; Dainer-Best, Justin; Parker, Suzanne; Rostrup, Nina; Stanley, Elizabeth A.

    2015-01-01

    We investigated the impact of mindfulness training (MT) on attentional performance lapses associated with task-unrelated thought (i.e., mind wandering). Periods of persistent and intensive demands may compromise attention and increase off-task thinking. Here, we investigated if MT may mitigate these deleterious effects and promote cognitive resilience in military cohorts enduring a high-demand interval of predeployment training. To better understand which aspects of MT programs are most beneficial, three military cohorts were examined. Two of the three groups were provided MT. One group received an 8-hour, 8-week variant of Mindfulness-based Mind Fitness Training (MMFT) emphasizing engagement in training exercises (training-focused MT, n = 40), a second group received a didactic-focused variant emphasizing content regarding stress and resilience (didactic-focused MT, n = 40), and the third group served as a no-training control (NTC, n = 24). Sustained Attention to Response Task (SART) performance was indexed in all military groups and a no-training civilian group (CIV, n = 45) before (T1) and after (T2) the MT course period. Attentional performance (measured by A’, a sensitivity index) was lower in NTC vs. CIV at T2, suggesting that performance suffers after enduring a high-demand predeployment interval relative to a similar time period of civilian life. Yet, there were significantly fewer performance lapses in the military cohorts receiving MT relative to NTC, with training-focused MT outperforming didactic-focused MT at T2. From T1 to T2, A’ degraded in NTC and didactic-focused MT but remained stable in training-focused MT and CIV. In sum, while protracted periods of high-demand military training may increase attentional performance lapses, practice-focused MT programs akin to training-focused MT may bolster attentional performance more than didactic-focused programs. As such, training-focused MT programs should be further examined in cohorts experiencing

  18. Minds "at attention": mindfulness training curbs attentional lapses in military cohorts.

    Directory of Open Access Journals (Sweden)

    Amishi P Jha

    Full Text Available We investigated the impact of mindfulness training (MT on attentional performance lapses associated with task-unrelated thought (i.e., mind wandering. Periods of persistent and intensive demands may compromise attention and increase off-task thinking. Here, we investigated if MT may mitigate these deleterious effects and promote cognitive resilience in military cohorts enduring a high-demand interval of predeployment training. To better understand which aspects of MT programs are most beneficial, three military cohorts were examined. Two of the three groups were provided MT. One group received an 8-hour, 8-week variant of Mindfulness-based Mind Fitness Training (MMFT emphasizing engagement in training exercises (training-focused MT, n = 40, a second group received a didactic-focused variant emphasizing content regarding stress and resilience (didactic-focused MT, n = 40, and the third group served as a no-training control (NTC, n = 24. Sustained Attention to Response Task (SART performance was indexed in all military groups and a no-training civilian group (CIV, n = 45 before (T1 and after (T2 the MT course period. Attentional performance (measured by A', a sensitivity index was lower in NTC vs. CIV at T2, suggesting that performance suffers after enduring a high-demand predeployment interval relative to a similar time period of civilian life. Yet, there were significantly fewer performance lapses in the military cohorts receiving MT relative to NTC, with training-focused MT outperforming didactic-focused MT at T2. From T1 to T2, A' degraded in NTC and didactic-focused MT but remained stable in training-focused MT and CIV. In sum, while protracted periods of high-demand military training may increase attentional performance lapses, practice-focused MT programs akin to training-focused MT may bolster attentional performance more than didactic-focused programs. As such, training-focused MT programs should be further examined in cohorts

  19. Growth Rate and Morphology of a Single Calcium Carbonate Crystal on Polysulfone Film Measured with Time Lapse Raman Micro Spectroscopy

    NARCIS (Netherlands)

    Liszka, B.; Lenferink, Aufrid T.M.; Otto, Cornelis

    2016-01-01

    The growth of single, self- nucleated calcium carbonate crystals on a polysulfone (PSU) film was investigated with high resolution, time lapse Raman imaging. The Raman images were acquired on the interface of the polymer with the crystal. The growth of crystals could thus be followed in time. PSU is

  20. Time-Lapse Joint Inversion of Cross-Well DC Resistivity and Seismic Data: A Numerical Investigation

    Science.gov (United States)

    Time-lapse joint inversion of geophysical data is required to image the evolution of oil reservoirs during production and enhanced oil recovery, CO2 sequestration, geothermal fields during production, and to monitor the evolution of contaminant plumes. Joint inversion schemes red...

  1. Micromechanical Time-Lapse X-ray CT Study of Fatigue Damage in Uni-Directional Fibre Composites

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Lowe, Tristan; Withers, Philip J.

    2015-01-01

    . The geometry of the cut-out is similar to that which will be used in the time-lapse study. As the micro-mechanical damage mechanisms are small features, it is necessary to obtain a high scan resolution which sets a limit to how large the field of view can be. Therefore, it is necessary to perform several scans...

  2. Land time-lapse CSEM : Collecting, modeling and inversion of CSEM data for a steam-injected oil field

    NARCIS (Netherlands)

    Schaller, A.M.

    2018-01-01

    Geophysical methods are widely used for hydrocarbon exploration and time-lapse measurements. One method that can be applied in place of or in addition to the routinely used seismic method, is the Controlled-Source ElectroMagnetic (CSEM) method. The work described in this thesis explores various

  3. Time-lapse micro-tomography analysis of the deformation response of a gellan-gum-based scaffold

    Czech Academy of Sciences Publication Activity Database

    Kytýř, Daniel; Fenclová, Nela; Zlámal, Petr; Kumpová, Ivana; Fíla, Tomáš; Koudelka_ml., Petr; Gantar, A.; Novak, S.

    2017-01-01

    Roč. 51, č. 3 (2017), s. 397-402 ISSN 1580-2949 Institutional support: RVO:68378297 Keywords : bone scaffold * gellan gum * time-lapse micro CT * digital volume correlation Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 0.436, year: 2016 http://mit.imt.si/Revija/izvodi/mit173/kytyr.pdf

  4. Mass conservative three-dimensional water tracer distribution from MCMC inversion of time-lapse GPR data

    NARCIS (Netherlands)

    Lalov, E.; Linde, N.; Vrugt, J.A.

    2012-01-01

    Time-lapse geophysical measurements are widely used to monitor the movement of water and solutes through the subsurface. Yet commonly used deterministic least squares inversions typically suffer from relatively poor mass recovery, spread overestimation, and limited ability to appropriately estimate

  5. Joint inversion of time-lapse VSP data for monitoring CO2 injection at the Farnsworth EOR field in Texas

    Science.gov (United States)

    Zhang, M.; Gao, K.; Balch, R. S.; Huang, L.

    2016-12-01

    During the Development Phase (Phase III) of the U.S. Southwest Regional Partnership on Carbon Sequestration (SWP), time-lapse 3D vertical seismic profiling (VSP) data were acquired to monitor CO2 injection/migration at the Farnsworth Enhanced Oil Recovery (EOR) field, in partnership with the industrial partner Chaparral Energy. The project is to inject a million tons of carbon dioxide into the target formation, the deep oil-bearing Morrow Formation in the Farnsworth Unit EOR field. Quantitative time-lapse seismic monitoring has the potential to track CO2 movement in geologic carbon storage sites. Los Alamos National Laboratory (LANL) has recently developed new full-waveform inversion methods to jointly invert time-lapse seismic data for changes in elastic and anisotropic parameters in target monitoring regions such as a CO2 reservoir. We apply our new joint inversion methods to time-lapse VSP data acquired at the Farnsworth EOR filed, and present some preliminary results showing geophysical properties changes in the reservoir.

  6. Calibrating vadose zone models with time-lapse gravity data: a forced infiltration experiment

    DEFF Research Database (Denmark)

    Christiansen, Lars; Hansen, Allan Bo; Zibar, Majken Caroline Looms

    A change in soil water content is a change in mass stored in the subsurface, and when large enough, can be measured with a gravity meter. Over the last few decades there has been increased use of ground-based time-lapse gravity measurements to infer hydrogeological parameters. These studies have...... focused on the saturated zone, with specific yield as the most prominent target parameter and with few exceptions, changes in storage in the vadose zone have been considered as noise. Here modeling results are presented suggesting that gravity changes will be measureable when soil moisture changes occur...... in the unsaturated zone. These results are confirmed by field measurements of gravity and georadar data at a forced infiltration experiment conducted over 14 days on a grassland area of 10 m by 10 m. An unsaturated zone infiltration model can be calibrated using the gravity data with good agreement to the field data...

  7. Slow speed—fast motion: time-lapse recordings in physics education

    Science.gov (United States)

    Vollmer, Michael; Möllmann, Klaus-Peter

    2018-05-01

    Video analysis with a 30 Hz frame rate is the standard tool in physics education. The development of affordable high-speed-cameras has extended the capabilities of the tool for much smaller time scales to the 1 ms range, using frame rates of typically up to 1000 frames s-1, allowing us to study transient physics phenomena happening too fast for the naked eye. Here we want to extend the range of phenomena which may be studied by video analysis in the opposite direction by focusing on much longer time scales ranging from minutes, hours to many days or even months. We discuss this time-lapse method, needed equipment and give a few hints of how to produce respective recordings for two specific experiments.

  8. Using time-lapse gravity for groundwater model calibration: An application to alluvial aquifer storage

    DEFF Research Database (Denmark)

    Christiansen, Lars; Binning, Philip John; Rosbjerg, Dan

    2011-01-01

    hydrogeophysical inversion to decrease parameter correlation in groundwater models. This is demonstrated for a model of riverbank infiltration where combined inversion successfully constrains hydraulic conductivity and specific yield in both an analytical and a numerical groundwater model. A sensitivity study...... shows that time-lapse gravity data are especially useful to constrain specific yield. Furthermore, we demonstrate that evapotranspiration, and riverbed conductance are better constrained by coupled inversion to gravity and head data than to head data alone. When estimating the four parameters...... simultaneously, the six correlation coefficients were reduced from unity when only head data were employed to significantly lower values when gravity and head data were combined. Our analysis reveals that the estimated parameter values are not very sensitive to the choice of weighting between head and gravity...

  9. Time-lapse seismic analysis of the North Sea Fulmar Field

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, David H.; McKenny, Robert S.; Burkhart, Tucker D.

    1998-12-31

    Time-lapse seismic analysis has been applied to two 3-D seismic surveys acquired over the central North Sea Fulmar field in a pre-production survey shot in 1977, reprocessed in 1987, and a survey in 1992. The Upper Jurassic reservoirs in the field have been under production since 1982. Differences in averaged impedance between the 1977 and 1992 surveys clearly show the effects of water influx and pressure decline. The changes observed in the seismic data are overall consistent with predictions obtained from a full-field, history-matched simulation. Differences in details may suggest areas of bypassed oil. Dta quality is not sufficient to serve as the sole basis for drilling decisions. 1 ref., 6 figs.

  10. A poly(dimethylsiloxane)-based device enabling time-lapse imaging with high spatial resolution

    International Nuclear Information System (INIS)

    Hirano, Masahiko; Hoshida, Tetsushi; Sakaue-Sawano, Asako; Miyawaki, Atsushi

    2010-01-01

    We have developed a regulator-free device that enables long-term incubation of mammalian cells for epi-fluorescence imaging, based on a concept that the size of sample to be gassed and heated is reduced to observation scale. A poly(dimethylsiloxane) block stamped on a coverslip works as a long-lasting supplier of CO 2 -rich gas to adjust bicarbonate-containing medium in a tiny chamber at physiological pH, and an oil-immersion objective warms cells across the coverslip. A time-lapse imaging experiment using HeLa cells stably expressing fluorescent cell-cycle indicators showed that the cells in the chamber proliferated with normal cell-cycle period over 2 days.

  11. Time-lapse cinematography in living Drosophila tissues: preparation of material.

    Science.gov (United States)

    Davis, Ilan; Parton, Richard M

    2006-11-01

    The fruit fly, Drosophila melanogaster, has been an extraordinarily successful model organism for studying the genetic basis of development and evolution. It is arguably the best-understood complex multicellular model system, owing its success to many factors. Recent developments in imaging techniques, in particular sophisticated fluorescence microscopy methods and equipment, now allow cellular events to be studied at high resolution in living material. This ability has enabled the study of features that tend to be lost or damaged by fixation, such as transient or dynamic events. Although many of the techniques of live cell imaging in Drosophila are shared with the greater community of cell biologists working on other model systems, studying living fly tissues presents unique difficulties in keeping the cells alive, introducing fluorescent probes, and imaging through thick hazy cytoplasm. This protocol outlines the preparation of major tissue types amenable to study by time-lapse cinematography and different methods for keeping them alive.

  12. Time-lapse cinematography of the capillary tube cell migration inhibition test.

    Science.gov (United States)

    Bray, M A

    1980-01-01

    The kinetics of human and guinea pig cell migration inhibition have been studied using time-lapse cinematography of cells migrating from capillary tubes. Guinea pig and human cells exhibit markedly different kinetics in the absence of inhibitors. Specific antigen causes a dose-related inhibition of migration for up to 60 h using guinea pig cells and a peak of inhibition after 18 h using the human leucocyte system. The timing of measurement of maximum activity more critical for the latter test. The kinetics of lymphokine generation have been examined and the migration inhibitory activity of the plant mitogen (PHA), a Kurloff cell product and a continuous cell line supernatant have been compared with the inhibitory profiles of lymphokine preparations and specific antigen.

  13. Time-lapse cinematography of dynamic changes occurring during in vitro development of human embryos.

    Science.gov (United States)

    Mio, Yasuyuki; Maeda, Kazuo

    2008-12-01

    The purpose of this study was to clarify developmental changes of early human embryos by using time-lapse cinematography (TLC). For human ova, fertilization and cleavage, development of the blastocyst, and hatching, as well as consequent changes were repeatedly photographed at intervals of 5-6 days by using an inverse microscope under stabilized temperature and pH. Photographs were taken at 30 frames per second and the movies were studied. Cinematography has increased our understanding of the morphologic mechanisms of fertilization, development, and behavior of early human embryos, and has identified the increased risk of monozygotic twin pregnancy based on prolonged incubation in vitro to the blastocyst stage. Using TLC, we observed the fertilization of an ovum by a single spermatozoon, followed by early cleavages, formation of the morula, blastocyst hatching, changes in the embryonic plates, and the development of monozygotic twins from the incubated blastocysts.

  14. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  15. Low-cost motility tracking system (LOCOMOTIS for time-lapse microscopy applications and cell visualisation.

    Directory of Open Access Journals (Sweden)

    Adam E Lynch

    Full Text Available Direct visualisation of cells for the purpose of studying their motility has typically required expensive microscopy equipment. However, recent advances in digital sensors mean that it is now possible to image cells for a fraction of the price of a standard microscope. Along with low-cost imaging there has also been a large increase in the availability of high quality, open-source analysis programs. In this study we describe the development and performance of an expandable cell motility system employing inexpensive, commercially available digital USB microscopes to image various cell types using time-lapse and perform tracking assays in proof-of-concept experiments. With this system we were able to measure and record three separate assays simultaneously on one personal computer using identical microscopes, and obtained tracking results comparable in quality to those from other studies that used standard, more expensive, equipment. The microscopes used in our system were capable of a maximum magnification of 413.6×. Although resolution was lower than that of a standard inverted microscope we found this difference to be indistinguishable at the magnification chosen for cell tracking experiments (206.8×. In preliminary cell culture experiments using our system, velocities (mean µm/min ± SE of 0.81 ± 0.01 (Biomphalaria glabrata hemocytes on uncoated plates, 1.17 ± 0.004 (MDA-MB-231 breast cancer cells, 1.24 ± 0.006 (SC5 mouse Sertoli cells and 2.21 ± 0.01 (B. glabrata hemocytes on Poly-L-Lysine coated plates, were measured and are consistent with previous reports. We believe that this system, coupled with open-source analysis software, demonstrates that higher throughput time-lapse imaging of cells for the purpose of studying motility can be an affordable option for all researchers.

  16. Low-cost motility tracking system (LOCOMOTIS) for time-lapse microscopy applications and cell visualisation.

    Science.gov (United States)

    Lynch, Adam E; Triajianto, Junian; Routledge, Edwin

    2014-01-01

    Direct visualisation of cells for the purpose of studying their motility has typically required expensive microscopy equipment. However, recent advances in digital sensors mean that it is now possible to image cells for a fraction of the price of a standard microscope. Along with low-cost imaging there has also been a large increase in the availability of high quality, open-source analysis programs. In this study we describe the development and performance of an expandable cell motility system employing inexpensive, commercially available digital USB microscopes to image various cell types using time-lapse and perform tracking assays in proof-of-concept experiments. With this system we were able to measure and record three separate assays simultaneously on one personal computer using identical microscopes, and obtained tracking results comparable in quality to those from other studies that used standard, more expensive, equipment. The microscopes used in our system were capable of a maximum magnification of 413.6×. Although resolution was lower than that of a standard inverted microscope we found this difference to be indistinguishable at the magnification chosen for cell tracking experiments (206.8×). In preliminary cell culture experiments using our system, velocities (mean µm/min ± SE) of 0.81 ± 0.01 (Biomphalaria glabrata hemocytes on uncoated plates), 1.17 ± 0.004 (MDA-MB-231 breast cancer cells), 1.24 ± 0.006 (SC5 mouse Sertoli cells) and 2.21 ± 0.01 (B. glabrata hemocytes on Poly-L-Lysine coated plates), were measured and are consistent with previous reports. We believe that this system, coupled with open-source analysis software, demonstrates that higher throughput time-lapse imaging of cells for the purpose of studying motility can be an affordable option for all researchers.

  17. Low-Cost Motility Tracking System (LOCOMOTIS) for Time-Lapse Microscopy Applications and Cell Visualisation

    Science.gov (United States)

    Lynch, Adam E.; Triajianto, Junian; Routledge, Edwin

    2014-01-01

    Direct visualisation of cells for the purpose of studying their motility has typically required expensive microscopy equipment. However, recent advances in digital sensors mean that it is now possible to image cells for a fraction of the price of a standard microscope. Along with low-cost imaging there has also been a large increase in the availability of high quality, open-source analysis programs. In this study we describe the development and performance of an expandable cell motility system employing inexpensive, commercially available digital USB microscopes to image various cell types using time-lapse and perform tracking assays in proof-of-concept experiments. With this system we were able to measure and record three separate assays simultaneously on one personal computer using identical microscopes, and obtained tracking results comparable in quality to those from other studies that used standard, more expensive, equipment. The microscopes used in our system were capable of a maximum magnification of 413.6×. Although resolution was lower than that of a standard inverted microscope we found this difference to be indistinguishable at the magnification chosen for cell tracking experiments (206.8×). In preliminary cell culture experiments using our system, velocities (mean µm/min ± SE) of 0.81±0.01 (Biomphalaria glabrata hemocytes on uncoated plates), 1.17±0.004 (MDA-MB-231 breast cancer cells), 1.24±0.006 (SC5 mouse Sertoli cells) and 2.21±0.01 (B. glabrata hemocytes on Poly-L-Lysine coated plates), were measured and are consistent with previous reports. We believe that this system, coupled with open-source analysis software, demonstrates that higher throughput time-lapse imaging of cells for the purpose of studying motility can be an affordable option for all researchers. PMID:25121722

  18. Evaluating time-lapse ERT for monitoring DNAPL remediation via numerical simulation

    Science.gov (United States)

    Power, C.; Karaoulis, M.; Gerhard, J.; Tsourlos, P.; Giannopoulos, A.

    2012-12-01

    Dense non-aqueous phase liquids (DNAPLs) remain a challenging geoenvironmental problem in the near subsurface. Numerous thermal, chemical, and biological treatment methods are being applied at sites but without a non-destructive, rapid technique to map the evolution of DNAPL mass in space and time, the degree of remedial success is difficult to quantify. Electrical resistivity tomography (ERT) has long been presented as highly promising in this context but has not yet become a practitioner's tool due to challenges in interpreting the survey results at real sites where the initial condition (DNAPL mass, DNAPL distribution, subsurface heterogeneity) is typically unknown. Recently, a new numerical model was presented that couples DNAPL and ERT simulation at the field scale, providing a tool for optimizing ERT application and interpretation at DNAPL sites (Power et al., 2011, Fall AGU, H31D-1191). The objective of this study is to employ this tool to evaluate the effectiveness of time-lapse ERT to monitor DNAPL source zone remediation, taking advantage of new inversion methodologies that exploit the differences in the target over time. Several three-dimensional releases of chlorinated solvent DNAPLs into heterogeneous clayey sand at the field scale were generated, varying in the depth and complexity of the source zone (target). Over time, dissolution of the DNAPL in groundwater was simulated with simultaneous mapping via periodic ERT surveys. Both surface and borehole ERT surveys were conducted for comparison purposes. The latest four-dimensional ERT inversion algorithms were employed to generate time-lapse isosurfaces of the DNAPL source zone for all cases. This methodology provided a qualitative assessment of the ability of ERT to track DNAPL mass removal for complex source zones in realistically heterogeneous environments. In addition, it provided a quantitative comparison between the actual DNAPL mass removed and that interpreted by ERT as a function of depth below

  19. Quantifying Effusion Rates at Active Volcanoes through Integrated Time-Lapse Laser Scanning and Photography

    Directory of Open Access Journals (Sweden)

    Neil Slatcher

    2015-11-01

    Full Text Available During volcanic eruptions, measurements of the rate at which magma is erupted underpin hazard assessments. For eruptions dominated by the effusion of lava, estimates are often made using satellite data; here, in a case study at Mount Etna (Sicily, we make the first measurements based on terrestrial laser scanning (TLS, and we also include explosive products. During the study period (17–21 July 2012, regular Strombolian explosions were occurring within the Bocca Nuova crater, producing a ~50 m-high scoria cone and a small lava flow field. TLS surveys over multi-day intervals determined a mean cone growth rate (effusive and explosive products of ~0.24 m3·s−1. Differences between 0.3-m resolution DEMs acquired at 10-minute intervals captured the evolution of a breakout lava flow lobe advancing at 0.01–0.03 m3·s−1. Partial occlusion within the crater prevented similar measurement of the main flow, but integrating TLS data with time-lapse imagery enabled lava viscosity (7.4 × 105 Pa·s to be derived from surface velocities and, hence, a flux of 0.11 m3·s−1 to be calculated. Total dense rock equivalent magma discharge estimates are ~0.1–0.2 m3·s−1 over the measurement period and suggest that simultaneous estimates from satellite data are somewhat overestimated. Our results support the use of integrated TLS and time-lapse photography for ground-truthing space-based measurements and highlight the value of interactive image analysis when automated approaches, such as particle image velocimetry (PIV, fail.

  20. Gliding motility of Babesia bovis merozoites visualized by time-lapse video microscopy.

    Directory of Open Access Journals (Sweden)

    Masahito Asada

    Full Text Available BACKGROUND: Babesia bovis is an apicomplexan intraerythrocytic protozoan parasite that induces babesiosis in cattle after transmission by ticks. During specific stages of the apicomplexan parasite lifecycle, such as the sporozoites of Plasmodium falciparum and tachyzoites of Toxoplasma gondii, host cells are targeted for invasion using a unique, active process termed "gliding motility". However, it is not thoroughly understood how the merozoites of B. bovis target and invade host red blood cells (RBCs, and gliding motility has so far not been observed in the parasite. METHODOLOGY/PRINCIPAL FINDINGS: Gliding motility of B. bovis merozoites was revealed by time-lapse video microscopy. The recorded images revealed that the process included egress of the merozoites from the infected RBC, gliding motility, and subsequent invasion into new RBCs. The gliding motility of B. bovis merozoites was similar to the helical gliding of Toxoplasma tachyzoites. The trails left by the merozoites were detected by indirect immunofluorescence assay using antiserum against B. bovis merozoite surface antigen 1. Inhibition of gliding motility by actin filament polymerization or depolymerization indicated that the gliding motility was driven by actomyosin dependent process. In addition, we revealed the timing of breakdown of the parasitophorous vacuole. Time-lapse image analysis of membrane-stained bovine RBCs showed formation and breakdown of the parasitophorous vacuole within ten minutes of invasion. CONCLUSIONS/SIGNIFICANCE: This is the first report of the gliding motility of B. bovis. Since merozoites of Plasmodium parasites do not glide on a substrate, the gliding motility of B. bovis merozoites is a notable finding.

  1. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  2. Vanemate töötamine välismaal - kuidas see mõjutab lapse elu : laste ja spetsialistide tõlgendused / Helen Pärna, Karmen Lai, Taimi Tulva

    Index Scriptorium Estoniae

    Pärna, Helen, 1983-

    2008-01-01

    Artikkel tugineb Helen Pärna magistriuurimusele. Ülevaade uurimustulemustest, mis puudutavad välismaale tööle läinud lapsevanemate lapse toimetulekut argieluga ning arutletakse selle üle, kuidas lapse lahusolek vanematest võib mõjutada lapse ja vanema vahelisi suhteid

  3. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  4. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  5. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  6. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  7. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  8. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  9. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  10. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  11. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  12. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  13. Discrete calculus methods for counting

    CERN Document Server

    Mariconda, Carlo

    2016-01-01

    This book provides an introduction to combinatorics, finite calculus, formal series, recurrences, and approximations of sums. Readers will find not only coverage of the basic elements of the subjects but also deep insights into a range of less common topics rarely considered within a single book, such as counting with occupancy constraints, a clear distinction between algebraic and analytical properties of formal power series, an introduction to discrete dynamical systems with a thorough description of Sarkovskii’s theorem, symbolic calculus, and a complete description of the Euler-Maclaurin formulas and their applications. Although several books touch on one or more of these aspects, precious few cover all of them. The authors, both pure mathematicians, have attempted to develop methods that will allow the student to formulate a given problem in a precise mathematical framework. The aim is to equip readers with a sound strategy for classifying and solving problems by pursuing a mathematically rigorous yet ...

  14. Counting paths with Schur transitions

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Pablo [Department of Physics and Astronomy, University of Lethbridge, Lethbridge, Alberta, T1K 3M4 (Canada); Kemp, Garreth [Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Véliz-Osorio, Alvaro, E-mail: aveliz@gmail.com [Mandelstam Institute for Theoretical Physics, University of the Witwatersrand, WITS 2050, Johannesburg (South Africa); School of Physics and Astronomy, Queen Mary, University of London, Mile End Road, London E1 4NS (United Kingdom)

    2016-10-15

    In this work we explore the structure of the branching graph of the unitary group using Schur transitions. We find that these transitions suggest a new combinatorial expression for counting paths in the branching graph. This formula, which is valid for any rank of the unitary group, reproduces known asymptotic results. We proceed to establish the general validity of this expression by a formal proof. The form of this equation strongly hints towards a quantum generalization. Thus, we introduce a notion of quantum relative dimension and subject it to the appropriate consistency tests. This new quantity finds its natural environment in the context of RCFTs and fractional statistics; where the already established notion of quantum dimension has proven to be of great physical importance.

  15. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  16. Monotoring of CO2 Sequestration at Sleipner Using Full Waveform Inversion in Time-lapse Mode.

    Science.gov (United States)

    Gosselet, A.; Singh, S. C.

    2007-12-01

    It is now widely admitted that recent increase of CO2 in the atmosphere is due to human activities. The consecutive greenhouse effect is a major ecological concern. Geological storage is one proposed way to reduce atmosphere CO2 emissions. The Sleipner methane field, North Sea, is the very first site where CO2 has been injected back into a deep saline aquifer. In 1996, the Norwegian company Statoil and its partners began the production of the methane. The extracted methane contains a relatively high ratio of CO2, between 4% and 9%, that has to be reduced below 2.5% before delivering into the pipeline. An environmental tax introduced in Norway as early as 1991 prompted the company to store the separated CO2 instead of releasing it into the atmosphere as usually done. The CO2 is injected at the base of the Utsira sands. This water bearing formation lies at a depth between 800 and 1000m and is sealed by a thick shale layer. Seismic monitoring is a key tool in this strategy from a security standpoint and for sequestration optimization itself. Consequently, 3D seismic data were acquired before injection in 1994 and after injection in 1999, 2001, 2002, 2004 and 2006. Well-log revealed that the reservoir is crossed by thin shale layers that are 1 to 10m thick. CO2 rises up and is confined vertically by the shale layers, favouring horizontal gas migration and creating gas bearing thin beds. Seismic imaging of the gas pockets is therefore a challenging problem because large velocity variations occur on very short distance. Classical processing of time-lapse data consists in subtracting repeated survey seismic traces from the pre- injection baseline traces to exhibit changes within the reservoir. This approach remains qualitative, providing only the shape and extent of the gas cloud. Instead, we propose to compare elastic models of the subsurface computed through 2D full wave form inversion, an advanced seismic imaging technique. This method is based on the wave equation

  17. In-situ, time-lapse study of extracellular polymeric substance discharge in Streptococcus mutans biofilm.

    Science.gov (United States)

    Liu, Bernard Haochih; Yu, Li-Chieh

    2017-02-01

    Streptococcus mutans is one of the main pathogens that cause tooth decay. By metabolizing carbohydrates, S. mutans emits extracellular polymeric substance (EPS) that adheres to the tooth surface and forms layers of biofilm. Periodontal disease occurs due to the low pH environment created by S. mutans biofilm, and such an acidic environment gradually erodes tooth enamel. Since the existence of EPS is essential in the formation of biofilm, the in-situ investigation of its generation and distribution in real time is the key to the control and suppression of S. mutans biofilm. Prior studies of the biofilm formation process by fluorescence microscope, scanning electron microscope, or spectroscope have roughly divided the mechanism into three stages: (1) initial attachment; (2) microcolonies; and (3) maturation. However, these analytical methods are incapable to observe real-time changes in different locations of the extracellular matrix, and to analyze mechanical properties for single bacteria in micro and nanoscale. Since atomic force microscopy (AFM) operates by precise control of tip-sample interaction forces in liquid and in air, living microorganisms can be analyzed under near-physiological conditions. Thus, analytical techniques based on AFM constitute powerful tools for the study of biological samples, both qualitatively and quantitatively. In this study, we used AFM to quantitatively track the changes of multiple nanomechanical properties of S. mutans, including dissipation energy, adhesion force, deformation, and elastic modulus at different metabolic stages. The data revealed that the bacterial extracellular matrix has a gradient distribution in stickiness, in which different stickiness indicates the variation of EPS compositions, freshness, and metabolic stages. In-situ, time-lapse AFM images showed the local generation and distribution of EPS at different times, in which the highest adhesion distributed along sides of the S. mutans cells. Through time-lapse

  18. TLM-Tracker: software for cell segmentation, tracking and lineage analysis in time-lapse microscopy movies.

    Science.gov (United States)

    Klein, Johannes; Leupold, Stefan; Biegler, Ilona; Biedendieck, Rebekka; Münch, Richard; Jahn, Dieter

    2012-09-01

    Time-lapse imaging in combination with fluorescence microscopy techniques enable the investigation of gene regulatory circuits and uncovered phenomena like culture heterogeneity. In this context, computational image processing for the analysis of single cell behaviour plays an increasing role in systems biology and mathematical modelling approaches. Consequently, we developed a software package with graphical user interface for the analysis of single bacterial cell behaviour. A new software called TLM-Tracker allows for the flexible and user-friendly interpretation for the segmentation, tracking and lineage analysis of microbial cells in time-lapse movies. The software package, including manual, tutorial video and examples, is available as Matlab code or executable binaries at http://www.tlmtracker.tu-bs.de.

  19. On the possibility of time-lapse ultrahigh-resolution optical coherence tomography for bladder cancer grading

    Science.gov (United States)

    Yuan, Zhijia; Chen, Bai; Ren, Hugang; Pan, Yingtian

    2009-09-01

    It has been recently demonstrated that the cellular details of bladder epithelium embedded in speckle noise can be uncovered with time-lapse ultrahigh-resolution optical coherence tomography (TL-uOCT) by proper time-lapse frame averaging that takes advantage of cellular micromotion in fresh biological tissue ex vivo. Here, spectral-domain 3-D TL-uOCT is reported to further improve the image fidelity, and new experimental evidence is presented to differentiate normal and cancerous nuclei of rodent bladder epithelia. Results of animal cancer study reveal that despite a slight overestimation (e.g., cancerous (e.g., high-grade DN''~13 μm) urothelia, which may potentially be very useful for enhancing the diagnosis of nonpapillary bladder cancer. More animal study is being conducted to examine the utility to differentiate hyperplasia, dysplasia, and carcinoma in situ.

  20. Sit still and pay attention: Using the Wii Balance-Board to detect lapses in concentration in children during psychophysical testing.

    Science.gov (United States)

    Jones, Pete R

    2018-05-16

    During psychophysical testing, a loss of concentration can cause observers to answer incorrectly, even when the stimulus is clearly perceptible. Such lapses limit the accuracy and speed of many psychophysical measurements. This study evaluates an automated technique for detecting lapses based on body movement (postural instability). Thirty-five children (8-11 years of age) and 34 adults performed a typical psychophysical task (orientation discrimination) while seated on a Wii Fit Balance Board: a gaming device that measures center of pressure (CoP). Incorrect responses on suprathreshold catch trials provided the "reference standard" measure of when lapses in concentration occurred. Children exhibited significantly greater variability in CoP on lapse trials, indicating that postural instability provides a feasible, real-time index of concentration. Limitations and potential applications of this method are discussed.

  1. Estimation of soil hydraulic parameters in the field by integrated hydrogeophysical inversion of time-lapse ground-penetrating radar data

    KAUST Repository

    Jadoon, Khan; Weihermü ller, Lutz; Scharnagl, Benedikt; Kowalsky, Michael B.; Bechtold, Michel; Hubbard, Susan S.; Vereecken, Harry; Lambot, Sé bastien

    2012-01-01

    An integrated hydrogeophysical inversion approach was used to remotely infer the unsaturated soil hydraulic parameters from time-lapse ground-penetrating radar (GPR) data collected at a fixed location over a bare agricultural field. The GPR model

  2. Conservatism predicts lapses from vegetarian/vegan diets to meat consumption (through lower social justice concerns and social support).

    Science.gov (United States)

    Hodson, Gordon; Earle, Megan

    2018-01-01

    Lapses from vegetarian and vegan (i.e., veg*n) food choices to meat consumption are very common, suggesting that sustaining veg*nism is challenging. But little is known about why people return to eating animals after initially deciding to avoid meat consumption. Several potential explanatory factors include personal inconvenience, meat cravings, awkwardness in social settings, or health/nutrition concerns. Here we test the degree to which political ideology predicts lapsing to meat consumption. Past research demonstrates that political ideology predicts present levels of meat consumption, whereby those higher in right-wing ideologies eat more animals, even after controlling for their hedonistic liking of meat (e.g., Dhont & Hodson, 2014). To what extent might political ideology predict whether one has lapsed from veg*n foods back to meat consumption? In a largely representative US community sample (N = 1313) of current and former veg*ns, those higher (vs. lower) in conservatism exhibited significantly greater odds of being a former than current veg*n, even after controlling for age, education, and gender. This ideology-lapsing relation was mediated (i.e., explained) by those higher (vs. lower) in conservatism: (a) adopting a veg*n diet for reasons less centered in justice concerns (animal rights, environment, feeding the poor); and (b) feeling socially unsupported in their endeavor. In contrast, factors such as differential meat craving or lifestyle inconvenience played little mediational role. These findings demonstrate that ideology and justice concerns are particularly relevant to understanding resilience in maintaining veg*n food choices. Implications for understanding why people eat meat, and how to develop intervention strategies, are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Model-Based Generation of Synthetic 3D Time-Lapse Sequences of Motile Cells with Growing Filopodia

    OpenAIRE

    Sorokin , Dmitry ,; Peterlik , Igor; Ulman , Vladimír ,; Svoboda , David; Maška , Martin

    2017-01-01

    International audience; The existence of benchmark datasets is essential to objectively evaluate various image analysis methods. Nevertheless, manual annotations of fluorescence microscopy image data are very laborious and not often practicable, especially in the case of 3D+t experiments. In this work, we propose a simulation system capable of generating 3D time-lapse sequences of single motile cells with filopodial protrusions, accompanied by inherently generated ground truth. The system con...

  4. How to connect time-lapse recorded trajectories of motile microorganisms with dynamical models in continuous time

    DEFF Research Database (Denmark)

    Pedersen, Jonas Nyvold; Li, Liang; Gradinaru, Cristian

    2016-01-01

    We provide a tool for data-driven modeling of motility, data being time-lapse recorded trajectories. Several mathematical properties of a model to be found can be gleaned from appropriate model-independent experimental statistics, if one understands how such statistics are distorted by the finite...... of these effects that are valid for any reasonable model for persistent random motion. Our findings are illustrated with experimental data and Monte Carlo simulations....

  5. Time-lapse three-dimensional inversion of complex conductivity data using an active time constrained (ATC) approach

    Science.gov (United States)

    Karaoulis, M.; Revil, A.; Werkema, D.D.; Minsley, B.J.; Woodruff, W.F.; Kemna, A.

    2011-01-01

    Induced polarization (more precisely the magnitude and phase of impedance of the subsurface) is measured using a network of electrodes located at the ground surface or in boreholes. This method yields important information related to the distribution of permeability and contaminants in the shallow subsurface. We propose a new time-lapse 3-D modelling and inversion algorithm to image the evolution of complex conductivity over time. We discretize the subsurface using hexahedron cells. Each cell is assigned a complex resistivity or conductivity value. Using the finite-element approach, we model the in-phase and out-of-phase (quadrature) electrical potentials on the 3-D grid, which are then transformed into apparent complex resistivity. Inhomogeneous Dirichlet boundary conditions are used at the boundary of the domain. The calculation of the Jacobian matrix is based on the principles of reciprocity. The goal of time-lapse inversion is to determine the change in the complex resistivity of each cell of the spatial grid as a function of time. Each model along the time axis is called a 'reference space model'. This approach can be simplified into an inverse problem looking for the optimum of several reference space models using the approximation that the material properties vary linearly in time between two subsequent reference models. Regularizations in both space domain and time domain reduce inversion artefacts and improve the stability of the inversion problem. In addition, the use of the time-lapse equations allows the simultaneous inversion of data obtained at different times in just one inversion step (4-D inversion). The advantages of this new inversion algorithm are demonstrated on synthetic time-lapse data resulting from the simulation of a salt tracer test in a heterogeneous random material described by an anisotropic semi-variogram. ?? 2011 The Authors Geophysical Journal International ?? 2011 RAS.

  6. Impact of Twitter intensity, time, and location on message lapse of bluebird's pursuit of fleas in Madagascar.

    Science.gov (United States)

    Da'ar, Omar B; Yunus, Faisel; Md Hossain, Nassif; Househ, Mowafa

    The recent outbreak of bubonic plague in Madagascar reminds us of the continuing public health challenges posed by such deadly diseases in various parts of the world years after their eradication. This study examines the role of Twitter in public health disease surveillance with special focus on how Twitter intensity, time, and location issues explain Twitter plague message delay. We retrospectively analyzed the Twitter feeds of the 2014 bubonic plague outbreak in Madagascar. The analyses are based on the plague-related data available in the public domain between November 19th and 27th 2014. The data were compiled in March 2015. We calculated the time differential between the tweets and retweets, and analyzed various characteristics of the Tweets including Twitter intensity of the users. A total of 6873 Twitter users were included in the study, of which 52% tweeted plague-related information during the morning hours (before mid-day), and 87% of the tweets came from the west of the epicenter of the plague. More importantly, while session of tweet lease and relative location had effect on message lapse, absolute location did not. Additionally, we found no evidence of differential effect of location on message lapse based on relative location i.e. tweets from west or east nor number of following. However, there is evidence that more intense Twitter use appears to have significant effect on message lapse such that as the number of tweets became more intense, time differential between the tweets and retweets increased while higher number of retweets diminished message lapse. This study affirms that Twitter can play an important role in ongoing disease surveillance and the timely dissemination of information during public health emergencies independent of the time and space restrictions. Further ways should be explored to embed social media channels in routine public health practice. Copyright © 2017 King Saud Bin Abdulaziz University for Health Sciences. Published by

  7. Counting Zero: Rethinking Feminist Epistemologies

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2017-10-01

    Full Text Available This article concerns feminist engagements with epistemologies. Feminist epistemologies have revealed and challenged the exclusions and denigrations at work in knowledge production processes. And yet, the emphasis on the partiality of knowledge and the non-innocence of any subject position also cast doubt on the possibility of feminist political communities. In view of this, it has been argued that the very parameter of epistemology poses limitations for feminism, for it leads to either political paralysis or prescriptive politics that in fact undoes the political of politics. From a different perspective, decolonial feminists argue for radical epistemic disobedience and delinking the move beyond the confines of Western systems of knowledge and its extractive knowledge economy. Nevertheless, the oppositional logic informs both feminist epistemologies and its critiques, which I argue is symptomatic of the epistemic habits of academic feminism. This article ends with a preliminary reconsideration of the question of origin through the figure of zero. It asks whether it might be possible to conceive of feminist epistemologies as performing the task of counting zero – accounting for origin, wholeness, and universality – that takes into account specificities without forfeiting coalition and claims to knowledge.

  8. Thermal erosion of a permafrost coastline: Improving process-based models using time-lapse photography

    Science.gov (United States)

    Wobus, C.; Anderson, R.; Overeem, I.; Matell, N.; Clow, G.; Urban, F.

    2011-01-01

    Coastal erosion rates locally exceeding 30 m y-1 have been documented along Alaska's Beaufort Sea coastline, and a number of studies suggest that these erosion rates have accelerated as a result of climate change. However, a lack of direct observational evidence has limited our progress in quantifying the specific processes that connect climate change to coastal erosion rates in the Arctic. In particular, while longer ice-free periods are likely to lead to both warmer surface waters and longer fetch, the relative roles of thermal and mechanical (wave) erosion in driving coastal retreat have not been comprehensively quantified. We focus on a permafrost coastline in the northern National Petroleum Reserve-Alaska (NPR-A), where coastal erosion rates have averaged 10-15 m y-1 over two years of direct monitoring. We take advantage of these extraordinary rates of coastal erosion to observe and quantify coastal erosion directly via time-lapse photography in combination with meteorological observations. Our observations indicate that the erosion of these bluffs is largely thermally driven, but that surface winds play a crucial role in exposing the frozen bluffs to the radiatively warmed seawater that drives melting of interstitial ice. To first order, erosion in this setting can be modeled using formulations developed to describe iceberg deterioration in the open ocean. These simple models provide a conceptual framework for evaluating how climate-induced changes in thermal and wave energy might influence future erosion rates in this setting.

  9. Monitoring of In-Situ Remediation By Time Lapse 3D Geo-Electric Measurements

    Science.gov (United States)

    Kanli, A. I.; Tildy, P.; Neducza, B.; Nagy, P.; Hegymegi, C.

    2017-12-01

    Injection of chemical oxidant solution to degrade the subsurface contaminants can be used for hydrocarbon contamination remediation. In this study, we developed a non-destructive measurement strategy to monitor oxidative in-situ remediation processes. The difficulties of the presented study originate from the small volume of conductive solution that can be used due to environmental considerations. Due to the effect of conductive groundwater and the high clay content of the targeted layer and the small volume of conductive solution that can be used due to environmental considerations, a site specific synthetic modelling is necessary for measurement design involving the results of preliminary 2D ERT measurements, electrical conductivity measurements of different active agents and expected resistivity changes calculated by soil resistivity modelling. Because of chemical biodegradation, the results of soil resistivity modelling have suggested that the reagent have complex effects on contaminated soils. As a result the plume of resistivity changes caused by the injected agent was determined showing strong fracturing effect because of the high pressure of injection. 3D time-lapse geo-electric measurements were proven to provide a usable monitoring tool for in-situ remediation as a result of our sophisticated tests and synthetic modelling.

  10. ESIAC: A data products system for ERTS imagery (time-lapse viewing and measuring)

    Science.gov (United States)

    Evans, W. E.; Serebreny, S. M.

    1974-01-01

    An Electronic Satellite Image Analysis Console (ESIAC) has been developed for visual analysis and objective measurement of earth resources imagery. The system is being employed to process imagery for use by USGS investigators in several different disciplines studying dynamic hydrologic conditions. The ESIAC provides facilities for storing registered image sequences in a magnetic video disc memory for subsequent recall, enhancement, and animated display in monochrome or color. The unique feature of the system is the capability to time-lapse the ERTS imagery and/or analytic displays of the imagery. Data products have included quantitative measurements of distances and areas, brightness profiles, and movie loops of selected themes. The applications of these data products are identified and include such diverse problem areas as measurement of snowfield extent, sediment plumes from estuary dicharge, playa inventory, phreatophyte and other vegetation changes. A comparative ranking of the electronic system in terms of accuracy, cost effectiveness and data output shows it to be a viable means of data analysis.

  11. Time-lapse analysis of potential cellular responsiveness to Johrei, a Japanese healing technique

    Directory of Open Access Journals (Sweden)

    Moore Dan

    2005-01-01

    Full Text Available Abstract Background Johrei is an alternative healing practice which involves the channeling of a purported universal healing energy to influence the health of another person. Despite little evidence to support the efficacy of such practices the use of such treatments is on the rise. Methods We assessed cultured human cancer cells for potential responsiveness to Johrei treatment from a short distance. Johrei treatment was delivered by practitioners who participated in teams of two, alternating every half hour for a total of four hours of treatment. The practitioners followed a defined set of mental procedures to minimize variability in mental states between experiments. An environmental chamber maintained optimal growth conditions for cells throughout the experiments. Computerized time-lapse microscopy allowed documentation of cancer cell proliferation and cell death before, during and after Johrei treatments. Results Comparing eight control experiments with eight Johrei intervention experiments, we found no evidence of a reproducible cellular response to Johrei treatment. Conclusion Cell death and proliferation rates of cultured human cancer cells do not appear responsive to Johrei treatment from a short distance.

  12. Non-rigid estimation of cell motion in calcium time-lapse images

    Science.gov (United States)

    Hachi, Siham; Lucumi Moreno, Edinson; Desmet, An-Sofie; Vanden Berghe, Pieter; Fleming, Ronan M. T.

    2016-03-01

    Calcium imaging is a widely used technique in neuroscience permitting the simultaneous monitoring of electro- physiological activity of hundreds of neurons at single cell resolution. Identification of neuronal activity requires rapid and reliable image analysis techniques, especially when neurons fire and move simultaneously over time. Traditionally, image segmentation is performed to extract individual neurons in the first frame of a calcium sequence. Thereafter, the mean intensity is calculated from the same region of interest in each frame to infer calcium signals. However, when cells move, deform and fire, this segmentation on its own generates artefacts and therefore biased neuronal activity. Therefore, there is a pressing need to develop a more efficient cell tracking technique. We hereby present a novel vision-based cell tracking scheme using a thin-plate spline deformable model. The thin-plate spline warping is based on control points detected using the Fast from Accelerated Segment Test descriptor and tracked using the Lucas-Kanade optical flow. Our method is able to track neurons in calcium time-series, even when there are large changes in intensity, such as during a firing event. The robustness and efficiency of the proposed approach is validated on real calcium time-lapse images of a neuronal population.

  13. Monitoring the snowpack volume in a sinkhole on Mount Lebanon using time lapse Photogrammetry

    Science.gov (United States)

    Abou Chakra, C.; Gascoin, S.; Somma, J.; Drapeau, L.; Fanise, P.

    2017-12-01

    Lebanon is one of the richest country in the Middle East for water resources, thanks to its mountain ranges that trigger precipitation from the moist air masses coming from the Mediterranean Sea. Snowpack acts as natural water storage in winter and supply fresh water during spring and summer. Yet, Lebanon is facing a serious water scarcity problem due to: i) decreasing amount of precipitation and climate change; ii) major growth of population of original residence and large number of refugees during regional wars. Therefore, continuous and systematic monitoring of the Lebanese water resources is becoming crucial. The Mount Lebanon is made of karstic depressions named "sinkholes". It is important to monitor the snowmelt process inside these sinkholes because of their key role as "containers" of seasonal snow. By isolating the snowpack from sun radiation and wind, they slow down the natural melting process and sublimation, thus delaying as well the low water flow period. An observatory is set up to monitor the snowpack evolution in a pilot sinkhole located in Mount Lebanon. The system uses three time-lapse cameras and structure-from-motion principles to reconstruct the snow volume within the sinkhole. The approach is validated by standard topographic surveys. The results indicate that snow depth can be retrieved with an accuracy between 20 and 60 cm (residuals standard deviation) and a low bias of 50 cm after coregistration of the digital elevation models.

  14. Untangling cell tracks: Quantifying cell migration by time lapse image data analysis.

    Science.gov (United States)

    Svensson, Carl-Magnus; Medyukhina, Anna; Belyaev, Ivan; Al-Zaben, Naim; Figge, Marc Thilo

    2018-03-01

    Automated microscopy has given researchers access to great amounts of live cell imaging data from in vitro and in vivo experiments. Much focus has been put on extracting cell tracks from such data using a plethora of segmentation and tracking algorithms, but further analysis is normally required to draw biologically relevant conclusions. Such relevant conclusions may be whether the migration is directed or not, whether the population has homogeneous or heterogeneous migration patterns. This review focuses on the analysis of cell migration data that are extracted from time lapse images. We discuss a range of measures and models used to analyze cell tracks independent of the biological system or the way the tracks were obtained. For single-cell migration, we focus on measures and models giving examples of biological systems where they have been applied, for example, migration of bacteria, fibroblasts, and immune cells. For collective migration, we describe the model systems wound healing, neural crest migration, and Drosophila gastrulation and discuss methods for cell migration within these systems. We also discuss the role of the extracellular matrix and subsequent differences between track analysis in vitro and in vivo. Besides methods and measures, we are putting special focus on the need for openly available data and code, as well as a lack of common vocabulary in cell track analysis. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  15. Direct prediction of spatially and temporally varying physical properties from time-lapse electrical resistance data

    Science.gov (United States)

    Hermans, Thomas; Oware, Erasmus; Caers, Jef

    2016-09-01

    Time-lapse applications of electrical methods have grown significantly over the last decade. However, the quantitative interpretation of tomograms in terms of physical properties, such as salinity, temperature or saturation, remains difficult. In many applications, geophysical models are transformed into hydrological models, but this transformation suffers from spatially and temporally varying resolution resulting from the regularization used by the deterministic inversion. In this study, we investigate a prediction-focused approach (PFA) to directly estimate subsurface physical properties with electrical resistance data, circumventing the need for classic tomographic inversions. First, we generate a prior set of resistance data and physical property forecast through hydrogeological and geophysical simulations mimicking the field experiment. We reduce the dimension of both the data and the forecast through principal component analysis in order to keep the most informative part of both sets in a reduced dimension space. Then, we apply canonical correlation analysis to explore the relationship between the data and the forecast in their reduced dimension space. If a linear relationship can be established, the posterior distribution of the forecast can be directly sampled using a Gaussian process regression where the field data scores are the conditioning data. In this paper, we demonstrate PFA for various physical property distributions. We also develop a framework to propagate the estimated noise level in the reduced dimension space. We validate the results by a Monte Carlo study on the posterior distribution and demonstrate that PFA yields accurate uncertainty for the cases studied.

  16. A clustering approach applied to time-lapse ERT interpretation - Case study of Lascaux cave

    Science.gov (United States)

    Xu, Shan; Sirieix, Colette; Riss, Joëlle; Malaurent, Philippe

    2017-09-01

    The Lascaux cave, located in southwest France, is one of the most important prehistoric cave in the world that shows Paleolithic paintings. This study aims to characterize the structure of the weathered epikarst setting located above the cave using Time-Lapse Electrical Resistivity Tomography (ERT) combined with local hydrogeological and climatic environmental data. Twenty ERT profiles were carried out for two years and helped us to record the seasonal and spatial variations of the electrical resistivity of the hydraulic upstream area of the Lascaux cave. The 20 interpreted resistivity models were merged into a single synthetic model using a multidimensional statistical method (Hierarchical Agglomerative Clustering). The individual blocks from the synthetic model associated with a similar resistivity variability were gathered into 7 clusters. We combined the resistivity temporal variations with climatic and hydrogeological data to propose a geo-electrical model that relates to a conceptual geological model. We provide a geological interpretation for each cluster regarding epikarst features. The superficial clusters (no 1 & 2) are linked to effective rainfall and trees, probably a fractured limestone. Another two clusters (no 6 & 7) are linked to detrital formations (sand and clay respectively). The cluster 3 may correspond to a marly limestone that forms a non-permeable horizon. Finally, the electrical behavior of the last two clusters (no 4 & 5) is correlated with the variation of flow rate; they may be a privileged feed zone of the flow in the cave.

  17. Environmental Monitoring Of Leaks Using Time Lapsed Long Electrode Electrical Resistivity

    International Nuclear Information System (INIS)

    Rucker, D.F.; Fink, J.B.; Loke, M.H.; Myers, D.A.

    2009-01-01

    Highly industrialized areas pose significant challenges for surface based electrical resistivity characterization and monitoring due to the high degree of metallic infrastructure. The infrastructure is typically several orders of magnitude more conductive than the desired targets, preventing the geophysicist from obtaining a clear picture of the subsurface. These challenges may be minimized if steel-cased wells are used as long electrodes. We demonstrate a method of using long electrodes in a complex nuclear waste facility to monitor a simulated leak from an underground storage tank. The leak was simulated by injecting high conductivity fluid in a perforated well and the resistivity measurements were made before and after the leak test. The data were processed in four dimensions, where a regularization procedure was applied in both the time and space domains. The results showed a lowered resistivity feature develop south of the injection site. The time lapsed regularization parameter had a strong influence on the differences in inverted resistivity between the pre and post datasets, potentially making calibration of the results to specific hydrogeologic parameters difficult.

  18. Exploring reflective 'critical incident' documentation of professionalism lapses in a medical undergraduate setting

    Directory of Open Access Journals (Sweden)

    McLachlan John C

    2009-07-01

    Full Text Available Abstract Background Measuring professionalism in undergraduate medical students is a difficult process, and no one method has currently emerged as the definitive means of assessment in this field. Student skills in reflection have been shown to be highly important in the development of professional behaviours. By studying student reflections on lapses in professional judgement, recorded as 'critical incidents', it is possible to explore themes which are significant for the development of professional behaviour in an undergraduate setting. Methods We examined critical incident reporting combined with optional written student reflection as a method for exploring professionalism in undergraduate medical students. 228 students split between Year 1 and 2 of one academic year of undergraduate medicine were studied retrospectively and a grounded theory approach to analysis was employed. Results This year generated 16 critical incident reports and corresponding student reflections, all of which were considered. In addition to identifying the nature of the critical incidents, 3 principal themes emerged. These were the impact and consequences of the report having been made, student reactions to the events (both positive and negative, and student responses regarding future actions. Conclusion This study indicates that unprofessional behaviour can be identified and challenged by both the faculty and the students involved, and suggests that positive behavioural changes might be made with the aim of preventing future occurrences. We provide a low cost approach of measuring and recording professional behaviour.

  19. Observation of human embryonic behavior in vitro by high-resolution time-lapse cinematography.

    Science.gov (United States)

    Iwata, Kyoko; Mio, Yasuyuki

    2016-07-01

    Assisted reproductive technology (ART) has yielded vast amounts of information and knowledge on human embryonic development in vitro; however, still images provide limited data on dynamic changes in the developing embryos. Using our high-resolution time-lapse cinematography (hR-TLC) system, we were able to describe normal human embryonic development continuously from the fertilization process to the hatched blastocyst stage in detail. Our hR-TLC observation also showed the embryonic abnormality of a third polar body (PB)-like substance likely containing a small pronucleus being extruded and resulting in single-pronucleus (1PN) formation, while our molecular biological investigations suggested the possibility that some 1PN embryos could be diploid, carrying both maternal and paternal genomes. Furthermore, in some embryos the extruded third PB-like substance was eventually re-absorbed into the ooplasm resulting in the formation of an uneven-sized, two-PN zygote. In addition, other hR-TLC observations showed that cytokinetic failure was correlated with equal-sized, multi-nucleated blastomeres that were also observed in the embryo showing early initiation of compaction. Assessment combining our hR-TLC with molecular biological techniques enables a better understanding of embryonic development and potential improvements in ART outcomes.

  20. Metamorphosis revealed: time-lapse three-dimensional imaging inside a living chrysalis.

    Science.gov (United States)

    Lowe, Tristan; Garwood, Russell J; Simonsen, Thomas J; Bradley, Robert S; Withers, Philip J

    2013-07-06

    Studies of model insects have greatly increased our understanding of animal development. Yet, they are limited in scope to this small pool of model species: a small number of representatives for a hyperdiverse group with highly varied developmental processes. One factor behind this narrow scope is the challenging nature of traditional methods of study, such as histology and dissection, which can preclude quantitative analysis and do not allow the development of a single individual to be followed. Here, we use high-resolution X-ray computed tomography (CT) to overcome these issues, and three-dimensionally image numerous lepidopteran pupae throughout their development. The resulting models are presented in the electronic supplementary material, as are figures and videos, documenting a single individual throughout development. They provide new insight and details of lepidopteran metamorphosis, and allow the measurement of tracheal and gut volume. Furthermore, this study demonstrates early and rapid development of the tracheae, which become visible in scans just 12 h after pupation. This suggests that there is less remodelling of the tracheal system than previously expected, and is methodologically important because the tracheal system is an often-understudied character system in development. In the future, this form of time-lapse CT-scanning could allow faster and more detailed developmental studies on a wider range of taxa than is presently possible.

  1. Agency, lapse in condom use and relationship intimacy among female sex workers in Jamaica.

    Science.gov (United States)

    Bailey, Althea E; Figueroa, John Peter

    2018-05-01

    This paper explores barriers to consistent condom use among female sex workers in Jamaica in a qualitative study using grounded theory. Multiple perspectives were sought through 44 in-depth interviews conducted with female sex workers, clients, the partners of sex workers and facilitators of sex work. Poverty and lack of education or skills, severely limited support systems as well as childhood abuse served to push the majority of participants into sex work and created vulnerability to HIV and other STIs. Despite these constraints, women found ways to exercise agency, ensure condom use, adopt protective measures and gain economic advantage in various aspects of the Jamaican sex trade. Perceived relationship intimacy between sex workers and their clients and/or their main partners emerged as the main factor contributing to reduced risk perception and inconsistent condom use. Relationship intimacy, with associated trust and affirmation of self, is the most important factor influencing sexual decision-making with respect to lapse in condom use among female sex workers in Jamaica. Study findings provide important insights that can enhance individual psychosocial, interpersonal and community-based interventions as well as inform environmental, structural and policy interventions to reduce risk and vulnerability among female sex workers.

  2. Reservoir characterization using production data and time-lapse seismic data

    Energy Technology Data Exchange (ETDEWEB)

    Dadashpour, Mohsen

    2009-12-15

    The most commonly encountered, and probably the most challenging task in reservoir engineering, is to describe the reservoir accurately and efficiently. An accurate description of a reservoir is crucial to the management of production and efficiency of oil recovery. Reservoir modeling is an important step in a reservoir's future performance, which is in direct proportion to reservoir management, risk analysis and making key economic decisions. The purpose of reservoir modeling is to not only build a model that is consistent with currently available data, but to build one that gives a good prediction of its future behavior. Updating a reservoir model to behave as closely as possible to the real reservoir is called history matching, and the estimation of reservoir properties using this method is known as parameter estimation problem, which is an inversion process. Parameter estimation is a time consuming and non-unique problem with a large solution space. Saturation and pressure changes, and porosity and permeability distributions are the most common parameters to estimate in the oil industry. These parameters must be specified in every node within a petroleum reservoir simulator. These parameters will be adjusted until the model prediction data match the observation data to a sufficient degree. The solution space reduction in this project is done by adding time-lapse seismic data as a new set of dynamic data to the traditional production histories. Time-lapse (or 4D) seismic consists of two or more 3D seismic surveys shot at different calendar times. Time-lapse seismic surveys produce images at different times in a reservoir's history. The seismic response of a reservoir may change due to changes in pressure, fluid saturation and temperature. These changes in seismic images due to a variation in saturation and pressure can be used as additional observation data. Time-lapse seismic data are dynamical measurements which have a high resolution in the

  3. Aberrant behavior of mouse embryo development after blastomere biopsy as observed through time-lapse cinematography.

    Science.gov (United States)

    Ugajin, Tomohisa; Terada, Yukihiro; Hasegawa, Hisataka; Velayo, Clarissa L; Nabeshima, Hiroshi; Yaegashi, Nobuo

    2010-05-15

    To analyze whether blastomere biopsy affects early embryonal growth as observed through time-lapse cinematography. Comparative prospective study between embryos in which a blastomere was removed and embryos in which a blastomere was not removed. An experimental laboratory of the university. We calculated the time between blastocele formation and the end of hatching, the time between the start and end of hatching, the number of contractions and expansions between blastocyst formation and the end of hatching, and the maximum diameter of the expanded blastocyst. In blastomere removal embryos, compaction began at the six-cell stage instead of at the eight-cell stage. We also found that hatching was delayed in these embryos as compared with matched controls. Moreover, the frequency of contraction and expansion movements after blastocyst formation was significantly higher in the blastomere removal group as compared with the control group. Finally, the maximum diameter of the expanded blastocyst just before hatching was not significantly different between both groups. These findings suggested that blastomere removal has an adverse effect on embryonic development around the time of hatching. Thus, future developments in preimplantation genetic diagnosis and screening should involve further consideration and caution in light of the influence of blastomere biopsy on embryonal growth. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  4. Mathematical analysis of endothelial sibling pair cell-cell interactions using time-lapse cinematography data.

    Science.gov (United States)

    Brown, L M; Ryan, U S; Absher, M; Olazabal, B M

    1982-01-01

    The sibling pairs from two different endothelial cell cultures were analysed by time-lapse cinematography. It was shown that wounded and regular (low density seeded) cultures differed in the behaviour patterns of their siblings. The cultures differed most significantly in the minimum interdivision time (IDT) which was 27% lower for the wounded culture. In the wounded culture there was a greater correlation of IDT values between sibling pairs. IDT values recorded both for paired and for unpaired cells were shorter for the wounded than for the regular culture. The mean IDT for unpaired cells was longer than the mean IDT for paired cells in the regular culture. Thus paired cells in the regular culture, had shorter IDTs, but not as short as in the wounded culture. It was significant that in the wounded culture the first generation of siblings were very close (less than 150 microns apart) at division. Overall the behaviour differences between the two cultures resulted in a higher rate of increase in cell numbers, and thus faster repair, of the wounded monolayer.

  5. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  6. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  7. Prediction of in-vitro developmental competence of early cleavage-stage mouse embryos with compact time-lapse equipment.

    Science.gov (United States)

    Pribenszky, Csaba; Losonczi, Eszter; Molnár, Miklós; Lang, Zsolt; Mátyás, Szabolcs; Rajczy, Klára; Molnár, Katalin; Kovács, Péter; Nagy, Péter; Conceicao, Jason; Vajta, Gábor

    2010-03-01

    Single blastocyst transfer is regarded as an efficient way to achieve high pregnancy rates and to avoid multiple pregnancies. Risk of cancellation of transfer due to a lack of available embryos may be reduced by early prediction of blastocyst development. Time-lapse investigation of mouse embryos shows that the time of the first and second cleavage (to the 2- and 3-cell stages, respectively) has a strong predictive value for further development in vitro, while cleavage from the 3-cell to the 4-cell stage has no predictive value. In humans, embryo fragmentation during preimplantation development has been associated with lower pregnancy rates and a higher incidence of developmental abnormalities. Analysis of time-lapse records shows that most fragmentation is reversible in the mouse and is resorbed in an average of 9 h. Daily or bi-daily microscopic checks of embryo development, applied routinely in human IVF laboratories, would fail to detect 36 or 72% of these fragmentations, respectively. Fragmentation occurring in a defined time frame has a strong predictive value for in-vitro embryo development. The practical compact system used in the present trial, based on the 'one camera per patient' principle, has eliminated the usual disadvantages of time-lapse investigations and is applicable for the routine follow-up of in-vitro embryo development. Copyright 2009 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  8. A Versatile Time-Lapse Camera System Developed by the Hawaiian Volcano Observatory for Use at Kilauea Volcano, Hawaii

    Science.gov (United States)

    Orr, Tim R.; Hoblitt, Richard P.

    2008-01-01

    Volcanoes can be difficult to study up close. Because it may be days, weeks, or even years between important events, direct observation is often impractical. In addition, volcanoes are often inaccessible due to their remote location and (or) harsh environmental conditions. An eruption adds another level of complexity to what already may be a difficult and dangerous situation. For these reasons, scientists at the U.S. Geological Survey (USGS) Hawaiian Volcano Observatory (HVO) have, for years, built camera systems to act as surrogate eyes. With the recent advances in digital-camera technology, these eyes are rapidly improving. One type of photographic monitoring involves the use of near-real-time network-enabled cameras installed at permanent sites (Hoblitt and others, in press). Time-lapse camera-systems, on the other hand, provide an inexpensive, easily transportable monitoring option that offers more versatility in site location. While time-lapse systems lack near-real-time capability, they provide higher image resolution and can be rapidly deployed in areas where the use of sophisticated telemetry required by the networked cameras systems is not practical. This report describes the latest generation (as of 2008) time-lapse camera system used by HVO for photograph acquisition in remote and hazardous sites on Kilauea Volcano.

  9. A time-series method for automated measurement of changes in mitotic and interphase duration from time-lapse movies.

    Directory of Open Access Journals (Sweden)

    Frederic D Sigoillot

    Full Text Available Automated time-lapse microscopy can visualize proliferation of large numbers of individual cells, enabling accurate measurement of the frequency of cell division and the duration of interphase and mitosis. However, extraction of quantitative information by manual inspection of time-lapse movies is too time-consuming to be useful for analysis of large experiments.Here we present an automated time-series approach that can measure changes in the duration of mitosis and interphase in individual cells expressing fluorescent histone 2B. The approach requires analysis of only 2 features, nuclear area and average intensity. Compared to supervised learning approaches, this method reduces processing time and does not require generation of training data sets. We demonstrate that this method is as sensitive as manual analysis in identifying small changes in interphase or mitotic duration induced by drug or siRNA treatment.This approach should facilitate automated analysis of high-throughput time-lapse data sets to identify small molecules or gene products that influence timing of cell division.

  10. Exploring the use patterns of a mobile health application for alcohol addiction before the initial lapse after detoxification.

    Science.gov (United States)

    Chih, Ming-Yuan

    2014-01-01

    How patients used Addiction-Comprehensive Health Enhancement Support System (A-CHESS)1, a mobile health intervention, while quitting drinking is worthy exploring. This study is to explore A-CHESS use patterns prior to the initial lapse reported after discharge from inpatient detoxification programs. 142 patients with alcohol addiction from two treatment agencies in the U.S. were included. A comprehensive set of A-CHESS use measures were developed based on a three-level system use framework and three A-CHESS service categories. In latent profile analyses, three A-CHESS system use patterns-inactive, passive, and active users-were found. Compared to the passive users (with the highest chance of the initial lapse), the active users (with the lowest chance of such behavior) participated more in online social activities, used more sessions, viewed more pages, and used A-CHESS longer. However, the chances of the initial lapse between A-CHESS user profiles were not statistically different. Implications of this finding were provided.

  11. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  12. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  13. Lapse time and frequency-dependent attenuation of coda waves in the Zagros continental collision zone in Southwestern Iran

    International Nuclear Information System (INIS)

    Rahimi, H; Hamzehloo, H

    2008-01-01

    The coda Q, Q c , were estimated for the Zagros continental collision zone in southwestern Iran by analyzing the coda waves of 51 local earthquakes recorded on the three stations of the Iranian National Seismic Network (INSN) with magnitudes of between 3.1 and 4.9 recorded in the region during March and April 2006. Most of the analyzed events are foreshocks and aftershocks of the Darb-e-Astane earthquake which occurred on 31 March 2006 with a magnitude of 6.1 (IIEES). The earthquakes had an epicentral distance of between 120 and 200 km and a focal depth of about 18 km. The Q c values were computed at nine central frequencies of 1.5, 2.0, 3.0, 4.0, 6.0, 8.0, 12.0, 16.0 and 20.0 Hz through eight lapse time windows from 25 to 60 s starting at double the time of the primary S-wave from the origin time using the time-domain coda-decay method of a single backscattering model. In this study the collected data were compared between the events that occurred before and after the main event (foreshocks and aftershocks). The analysis showed a significant variation in the value of coda, Q, for the study region in different lapse times and frequencies. The variation of the quality factor, Q c , before and after the main event was estimated at different lapse time windows to observe its effect with depth. The estimated average frequency-dependent relation of Q c for foreshocks varies from Q c = (144 ± 24)f (0.42±0.23) at 25 s to Q c = (85 ± 10)f (0.92±0.11) at 60 s lapse window time length, respectively. For aftershocks, it varies from Q c = (121 ± 55)f (0.97±0.26) at 25 s to Q c = (212 ± 59)f (0.82±0.15) at 60 s. The averages of Q c in all stations and lapse times window are obtained as Q c = 99f 0.84 and Q c = 178f 0.86 for foreshocks and aftershocks, respectively. The Q frequency relationship for foreshocks is similar to that for the South Carolina, Koyna, western Anatolia and Aleutian earthquakes, whereas for aftershocks it is similar to the Kumaun, NW Himalaya and

  14. STUDY OF TIME LAPSE IN FOREIGN BODY ASPIRATION IN RELATION TO CHEST X - RAY AND TYPE OF FOREIGN BODY

    Directory of Open Access Journals (Sweden)

    Salma

    2015-10-01

    Full Text Available INTRODUCTI ON: Foreign body aspiration in pediatrics is a potentially fatal accident which will continue until children explore their surroundings with their hand and mouth. Pediatric aspirations will persist until mankind exists. Not all foreign body aspirations are witnessed hence chances of delay in diagnosing an aspiration are high. Delay in diagnosis depends on site and character of foreign body aspirated. The chest x - ray findings and type of foreign body extracted vary depending on the duration the foreign body remains in airway . OBJECTIVE: To study the X - ray finding in pediatric airway aspiration and its relation to time lapse, the type and site of lodgment of foreign body extracted via bronchoscopy. The type of foreign body in relation to time lapse in aspiration. MATERIAL AND METHODS: This was a prospective study done in Bapuji child health institute and research center, JJM Medical College, Davangere . History and pre bronchoscopy x - Ray finding were noted for 65 children who were posted for suspicious bronchoscopy from August 2011 to September 2013. 11 children were excluded from study as they showed no foreign body on bronchoscopy. Time lapse in aspir ation and seeking medical care was noted. The bronchoscopic findings regarding site of foreign body lodgment and type of foreign body were recorded. The type of foreign body and variation of x - ray picture in relation to time lapse in aspiration were noted. Data collected was analyzed using descriptive statistics. RESULT: It was observed that mean age was 28 months. About 80% of the cases were between 1 to 3 years age. 82% (n=53/54 were radio lucent foreign body, only 1.5% (n=1/54 were radio o paque. Site of lodgment of foreign body was right main bronchus in 48% (n=26/54, left main bronchus 46% (n=25/54 , tracheal 1.85% (n=1/54, subglottic 1.85% (n=1/54, carinal 1.85% (n=1/54, multiple site i.e. left bronchus +right bronchus+ carinal 1.85% (n=1/54. Groundnut was most common

  15. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  16. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  17. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  18. Lazy reference counting for the Microgrid

    NARCIS (Netherlands)

    Poss, R.; Grelck, C.; Herhut, S.; Scholz, S.-B.

    2012-01-01

    This papers revisits non-deferred reference counting, a common technique to ensure that potentially shared large heap objects can be reused safely when they are both input and output to computations. Traditionally, thread-safe reference counting exploit implicit memory-based communication of counter

  19. A Word Count of Modern Arabic Prose.

    Science.gov (United States)

    Landau, Jacob M.

    This book presents a word count of Arabic prose based on 60 twentieth-century Egyptian books. The text is divided into an alphabetical list and a word frequency list. This word count is intended as an aid in the: (1) writing of primers and the compilation of graded readers, (2) examination of the vocabulary selection of primers and readers…

  20. 2013 Kids Count in Colorado! Community Matters

    Science.gov (United States)

    Colorado Children's Campaign, 2013

    2013-01-01

    "Kids Count in Colorado!" is an annual publication of the Children's Campaign, providing state and county level data on child well-being factors including child health, education, and economic status. Since its first release 20 years ago, "Kids Count in Colorado!" has become the most trusted source for data and information on…

  1. Time lapse photography as an approach to understanding glide avalanche activity

    Science.gov (United States)

    Hendrikx, Jordy; Peitzsch, Erich H.; Fagre, Daniel B.

    2012-01-01

    Avalanches resulting from glide cracks are notoriously difficult to forecast, but are a recurring problem for numerous avalanche forecasting programs. In some cases glide cracks are observed to open and then melt away in situ. In other cases, they open and then fail catastrophically as large, full-depth avalanches. Our understanding and management of these phenomena are currently limited. It is thought that an increase in the rate of snow gliding occurs prior to full-depth avalanche activity so frequent observation of glide crack movement can provide an index of instability. During spring 2011 in Glacier National Park, Montana, USA, we began an approach to track glide crack avalanche activity using a time-lapse camera focused on a southwest facing glide crack. This crack melted in-situ without failing as a glide avalanche, while other nearby glide cracks on north through southeast aspects failed. In spring 2012, a camera was aimed at a large and productive glide crack adjacent to the Going to the Sun Road. We captured three unique glide events in the field of view. Unfortunately, all of them either failed very quickly, or during periods of obscured view, so measurements of glide rate could not be obtained. However, we compared the hourly meteorological variables during the period of glide activity to the same variables prior to glide activity. The variables air temperature, relative humidity, air pressure, incoming and reflected long wave radiation, SWE, total precipitation, and snow depth were found to be statistically different for our cases examined. We propose that these are some of the potential precursors for glide avalanche activity, but do urge caution in their use, due to the simple approach and small data set size. It is hoped that by introducing a workable method to easily record glide crack movement, combined with ongoing analysis of the associated meteorological data, we will improve our understanding of when, or if, glide avalanche activity will ensue.

  2. Attentional Lapses of Adults with Attention Deficit Hyperactivity Disorder in Tasks of Sustained Attention.

    Science.gov (United States)

    Gmehlin, Dennis; Fuermaier, Anselm B M; Walther, Stephan; Tucha, Lara; Koerts, Janneke; Lange, Klaus W; Tucha, Oliver; Weisbrod, Matthias; Aschenbrenner, Steffen

    2016-06-01

    Adults with attention deficit hyperactivity disorder (ADHD) show attentional dysfunction such as distractibility and mind-wandering, especially in lengthy tasks. However, fundamentals of dysfunction are ambiguous and relationships of neuropsychological test parameters with self-report measures of ADHD symptoms are marginal. We hypothesize that basic deficits in sustaining attention explain more complex attentional dysfunction in persons with ADHD and relate to ADHD symptoms. Attentional function was analyzed by computing ex-Gaussian parameters for 3 time Blocks in a 20 min test of sustained alertness. Changes in performance across these blocks were analyzed by comparing adult persons with ADHD (n = 24) with healthy matched controls (n = 24) and correlated with neuropsychological measures of selective and divided attention as well as self-report measures of ADHD symptoms. We found a significantly steeper increase in the number of slow responses (ex-Gaussian parameter τ) in persons with ADHD with time on task in basic sustained alertness. They also performed significantly worse in tasks of sustained selective and divided attention. However, after controlling for an increase in τ during the alertness task, significant differences between groups disappeared for divided and partly selective attention. Increases in τ in the sustained alertness task correlated significantly with self-report measures of ADHD symptoms. Our results provide evidence that very basic deficits in sustaining attention in adults with ADHD are related to infrequent slow responses (=attentional lapses), with changes over time being relevant for more complex attentional function and experienced ADHD symptoms in everyday life. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Spatio-Temporal Variation and Monsoon Effect on the Temperature Lapse Rate of a Subtropical Island

    Directory of Open Access Journals (Sweden)

    Ching-An Chiu

    2014-01-01

    Full Text Available Temperature lapse rate (TLR has been widely used in the prediction of mountain climate and vegetation and in many ecological models. The aims of this paper are to explore the spatio-temporal variations and monsoon effects on the TLR in the subtropical island of Taiwan with its steep Central Mountain Region (CMR. A TLR analysis using the 32-year monthly mean air temperatures and elevations from 219 weather stations (sea level to 3852 m a.s.l. was performed based on different geographical regions and monsoon exposures. The results revealed that the average TLR for all of Taiwan is -5.17°C km-1, with a general tendency to be steeper in summer and shallower in winter. The results are also shallower than the typical or global average TLR of -6.5°C km-1. During the prevailing northeast monsoon season (winter, the TLR exhibits a contrast between the windward side (steeper, -5.97°C km-1 and the leeward side (shallower, -4.51°C km-1. From the diagnosis on spatial characteristics of monthly cloud amount and vertical atmospheric profiles, this contrasting phenomenon may be explained by the warming effect of onshore stratus clouds (500 - 2500 m depth on cold and dry Siberian monsoon air on the windward side of the CMR. On the southwestern leeward side of the CMR, the low-level (1500 m, the weak ventilation atmosphere and temperature inversion make the TLR shallower than on the windward side.

  4. The altitudinal temperature lapse rates applied to high elevation rockfalls studies in the Western European Alps

    Science.gov (United States)

    Nigrelli, Guido; Fratianni, Simona; Zampollo, Arianna; Turconi, Laura; Chiarle, Marta

    2018-02-01

    Temperature is one of the most important aspects of mountain climates. The relationships between air temperature and rockfalls at high-elevation sites are very important to know, but are also very difficult to study. In relation to this, a reliable method to estimate air temperatures at high-elevation sites is to apply the altitudinal temperature lapse rates (ATLR). The aims of this work are to quantify the values and the variability of the hourly ATLR and to apply this to estimated temperatures at high-elevation sites for rockfalls studies. To calculate ATLR prior the rockfalls, we used data acquired from two automatic weather stations that are located at an elevation above 2500 m. The sensors/instruments of these two stations are reliable because subjected to an accurate control and calibration once for year and the raw data have passed two automatic quality controls. Our study has yielded the following main results: (i) hourly ATLR increases slightly with increasing altitude, (ii) it is possible to estimate temperature at high-elevation sites with a good level of accuracy using ATLR, and (iii) temperature plays an important role on slope failures that occur at high-elevation sites and its importance is much more evident if the values oscillate around 0 °C with an amplitude of ±5 °C during the previous time-period. For these studies, it is not enough to improve the knowledge on air temperature, but it is necessary to develop an integrated knowledge of the thermal conditions of different materials involved in these processes (rock, debris, ice, water). Moreover, this integrated knowledge must be acquired by means of sensors and acquisition chains with known metrological traceability and uncertainty of measurements.

  5. Variation in Phenometric Lapse Rates in Pasture Resources across Four Rayons in Kyrgyzstan

    Science.gov (United States)

    Henebry, G. M.; Tomaszewska, M. A.; Kelgenbaeva, K.

    2017-12-01

    High elevation pasture resources form the foundation of agro-pastoralist livelihoods in Kyrgyzstan and elsewhere in montane Central Asia. We explore the temporal and the topographical variation in phenometric lapse rates (PLRs: the change in a phenometric as a function of elevation) across four rayons in two oblasts of the Kyrgyz Republic—Alay, At-Bashy, Chong Alay, and Naryn—with the aim of identifying and quantifying robust generic patterns in the PLRs. We evaluate two fundamental phenometrics derived from the downward convex quadratic model of land surface phenology that links the NDVI to accumulated growing degree-day (AGDD). The peak height (PH) is the maximum NDVI value obtained from the fitted model. The thermal time to peak (TTP) is the amount of AGDD required to reach the PH. We fitted sixteen years of Landsat NDVI data at 30 m spatial resolution to annual AGDD progressions derived from MODIS land surface temperature time series at 1 km spatial resolution, yielding maps for each phenometric. If the coefficient of determination was less than 0.5, then the model fit was deemed a failure. We classified the reliability of pasture resources into five classes based on the number of years of successful model fit: very persistent (14-16 y); persistent (11-13 y); marginal (7-10 y); occasional (4-6); and rare (1-3). We explore the interactive roles of elevation, slope, aspect, latitude, and rayon on the PLRs and pasture resource persistence to identify critical areas for resource management.

  6. Tracking snowmelt in the subsurface: time-lapse electrical resistivity imaging on an alpine hill slope.

    Science.gov (United States)

    Thayer, D.; Parsekian, A.; Hyde, K.; Beverly, D.; Speckman, H. N.; Ewers, B. E.

    2015-12-01

    In the mountain West region the winter snowpack provides more than 70% of our annual water supply. Modeling and predicting the timing and magnitude of snowmelt-driven water yield is difficult due to the complexities of hydrologic systems that move meltwater from snow to rivers. Particular challenges are understanding the temporal and spatial domain of subsurface hydraulic processes at relevant scales, which range from points to catchments. Subsurface characterization often requires borehole instrumentation, which is expensive and extremely difficult to install in remote, rugged terrain. Advancements in non-invasive geophysical methods allow us to monitor changes in geophysical parameters over time and infer changes in hydraulic processes. In the No-Name experimental catchment in the Medicine Bow National Forest in Wyoming, we are conducting a multi-season, time-lapse electrical resistivity imaging survey on a sub-alpine hill slope. This south-facing, partially forested slope ranges from 5 degrees to 35 degrees in steepness and consists of a soil mantle covering buried glacial talus deposits of unknown depth. A permanent grid of down-slope and cross-slope electrode arrays is monitored up to four times a day. The arrays span the entire vertical distance of the slope, from an exposed bedrock ridge to a seasonal drainage below, and cover treed and non-treed areas. Geophysical measurements are augmented by temperature and moisture time-series instrumented below the surface in a contiguous 3 meter borehole. A time-series of multiple resistivity models each day from May to July shows the changing distribution of subsurface moisture during a seasonal drying sequence punctuated by isolated rain events. Spatial patterns of changing moisture indicate that soil and gravel in the top two meters drain into a saturated layer parallel to the slope which overlies less saturated material. These results suggest that water from snowmelt and rain events tends to move down-slope beneath

  7. ENVIRONMENTAL MONITORING OF LEAKS USING TIME LAPSED LONG ELECTRODE ELECTRICAL RESISTIVITY

    International Nuclear Information System (INIS)

    Myers, D.A.; Rucker, D.F.; Fink, J.B.; Loke, M.H.

    2009-01-01

    Highly industrialized areas pose challenges for surface electrical resistivity characterization due to metallic infrastructure. The infrastructure is typically more conductive than the desired targets and will mask the deeper subsurface information. These challenges may be minimized if steel-cased wells are used as long electrodes in the area near the target. We demonstrate a method of using long electrodes to electrically monitor a simulated leak from an underground storage tank with both synthetic examples and a field demonstration. The synthetic examples place a simple target of varying electrical properties beneath a very low resistivity layer. The layer is meant to replicate the effects of infrastructure. Both surface and long electrodes are tested on the synthetic domain. The leak demonstration for the field experiment is simulated by injecting a high conductivity fluid in a perforated well within the S tank farm at Hanford, and the resistivity measurements are made before and after the leak test. All data are processed in four dimensions, where a regularization procedure is applied in both the time and space domains. The synthetic test case shows that the long electrode ERM could detect relative changes in resistivity that are commensurate with the differing target properties. The surface electrodes, on the other hand, had a more difficult time matching the original target's footprint. The field results shows a lowered resistivity feature develop south of the injection site after cessation of the injections. The time lapsed regularization parameter has a strong influence on the differences in inverted resistivity between the pre and post injection datasets, but the interpretation of the target is consistent across all values of the parameter. The long electrode ERM method may provide a tool for near real-time monitoring of leaking underground storage tanks.

  8. Applications of quantitative time lapse holographic imaging to the development of complex pharmaceutical nano formulations

    Science.gov (United States)

    Luther, Ed; Mendes, Livia; Pan, Jiayi; Costa, Daniel; Sarisozen, Can; Torchilin, Vladimir

    2018-02-01

    We rely on in vitro cellular cultures to evaluate the effects of the components of multifunctional nano-based formulations under development. We employ an incubator-adapted, label-free holographic imaging cytometer HoloMonitor M4® (Phase Holographic Imaging, Lund, Sweden) to obtain multi-day time-lapse sequences at 5- minute intervals. An automated stage allows hand-free acquisition of multiple fields of view. Our system is based on the Mach-Zehnder interferometry principle to create interference patterns which are deconvolved to produce images of the optical thickness of the field of view. These images are automatically segmented resulting in a full complement of quantitative morphological features, such as optical volume, thickness, and area amongst many others. Precise XY cell locations and the time of acquisition are also recorded. Visualization is best achieved by novel 4-Dimensional plots, where XY position is plotted overtime time (Z-directions) and cell-thickness is coded as color or gray scale brightness. Fundamental events of interest, i.e., cells undergoing mitosis or mitotic dysfunction, cell death, cell-to-cell interactions, motility are discernable. We use both 2D and 3D models of the tumor microenvironment. We report our new analysis method to track feature changes over time based on a 4-sample version of the Kolmogorov-Smirnov test. Feature A is compared to Control A, and Feature B is compared to Control B to give a 2D probability plot of the feature changes over time. As a result, we efficiently obtain vectors quantifying feature changes over time in various sample conditions, i.e., changing compound concentrations or multi-compound combinations.

  9. Microsoft excel spreadsheets for calculation of P-V-T relations and thermodynamic properties from equations of state of MgO, diamond and nine metals as pressure markers in high-pressure and high-temperature experiments

    Science.gov (United States)

    Sokolova, Tatiana S.; Dorogokupets, Peter I.; Dymshits, Anna M.; Danilov, Boris S.; Litasov, Konstantin D.

    2016-09-01

    We present Microsoft Excel spreadsheets for calculation of thermodynamic functions and P-V-T properties of MgO, diamond and 9 metals, Al, Cu, Ag, Au, Pt, Nb, Ta, Mo, and W, depending on temperature and volume or temperature and pressure. The spreadsheets include the most common pressure markers used in in situ experiments with diamond anvil cell and multianvil techniques. The calculations are based on the equation of state formalism via the Helmholtz free energy. The program was developed using Visual Basic for Applications in Microsoft Excel and is a time-efficient tool to evaluate volume, pressure and other thermodynamic functions using T-P and T-V data only as input parameters. This application is aimed to solve practical issues of high pressure experiments in geosciences and mineral physics.

  10. The performance of a novel flat heat pipe based thermal and PV/T (photovoltaic and thermal systems) solar collector that can be used as an energy-active building envelope material

    International Nuclear Information System (INIS)

    Jouhara, H.; Milko, J.; Danielewicz, J.; Sayegh, M.A.; Szulgowska-Zgrzywa, M.; Ramos, J.B.; Lester, S.P.

    2016-01-01

    A novel flat heat pipe design has been developed and utilised as a building envelope and thermal solar collector with and without (PV) bonded directly to its surface. The design of the new solar collector has been validated through full scale testing in Cardiff, UK where solar/thermal, uncooled PV and PV/T tests were carried out on three identical systems, simultaneously. The tests showed a solar/thermal energy conversion efficiency of around 64% for the collector with no PV and 50% for the system with the PV layer on it. The effect of cooling on the solar/electrical energy conversion efficiency was also investigated and an efficiency increase of about 15% was recorded for the cooled PV system due to the provided homogenous cooling. The new flat heat pipe solar collector is given the name “heat mat” and, in addition to being an efficient solar collector type, it is also designed to convert a building envelope materials to become energy-active. A full size roof that utilise this new building envelope material is reported in this paper to demonstrate the way this new collector is integrated as a building envelope material to form a roof. A thermal absorption test, in a controlled environment, from the ambient to the heat mat with no solar radiation is also reported. The test has proved the heat mat as an efficient thermal absorber from the ambient to the intermediate fluid that deliver the heat energy to the heat pump system. - Highlights: • A new flat heat pipe PV/T system that can be used as building materials is reported. • The new solar collector enhanced the performance of the PV by about 15%. • The new solar collector is capable of absorbing heat from ambient efficiently. • The new system is efficient from the solar/thermal conversion point of view.

  11. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  12. An Adaptive Smoother for Counting Measurements

    International Nuclear Information System (INIS)

    Kondrasovs Vladimir; Coulon Romain; Normand Stephane

    2013-06-01

    Counting measurements associated with nuclear instruments are tricky to carry out due to the stochastic process of the radioactivity. Indeed events counting have to be processed and filtered in order to display a stable count rate value and to allow variations monitoring in the measured activity. Smoothers (as the moving average) are adjusted by a time constant defined as a compromise between stability and response time. A new approach has been developed and consists in improving the response time while maintaining count rate stability. It uses the combination of a smoother together with a detection filter. A memory of counting data is processed to calculate several count rate estimates using several integration times. These estimates are then sorted into the memory from short to long integration times. A measurement position, in terms of integration time, is then chosen into this memory after a detection test. An inhomogeneity into the Poisson counting process is detected by comparison between current position estimate and the other estimates contained into the memory in respect with the associated statistical variance calculated with homogeneous assumption. The measurement position (historical time) and the ability to forget an obsolete data or to keep in memory a useful data are managed using the detection test result. The proposed smoother is then an adaptive and a learning algorithm allowing an optimization of the response time while maintaining measurement counting stability and converging efficiently to the best counting estimate after an effective change in activity. This algorithm has also the specificity to be low recursive and thus easily embedded into DSP electronics based on FPGA or micro-controllers meeting 'real life' time requirements. (authors)

  13. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  14. Radiation Counting System Software Using Visual Basic

    International Nuclear Information System (INIS)

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  15. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  16. Counts and colors of faint galaxies

    International Nuclear Information System (INIS)

    Kron, R.G.

    1980-01-01

    The color distribution of faint galaxies is an observational dimension which has not yet been fully exploited, despite the important constraints obtainable for galaxy evolution and cosmology. Number-magnitude counts alone contain very diluted information about the state of things because galaxies from a wide range in redshift contribute to the counts at each magnitude. The most-frequently-seen type of galaxy depends on the luminosity function and the relative proportions of galaxies of different spectral classes. The addition of color as a measured quantity can thus considerably sharpen the interpretation of galaxy counts since the apparent color depends on the redshift and rest-frame spectrum. (Auth.)

  17. Effect of time lapse on the diagnostic accuracy of cone beam computed tomography for detection of vertical root fractures

    Energy Technology Data Exchange (ETDEWEB)

    Eskandarloo, Amir; Shokri, Abbas, E-mail: Dr.a.shokri@gmail.com [Dental Research Center, Department of Oral and Maxillofacial Radiology, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Asl, Amin Mahdavi [Department of Oral and Maxillofacial Radiology, Golestan University of Medical Sciences, Gorgan (Iran, Islamic Republic of); Jalalzadeh, Mohsen [Department of Endodontics, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Tayari, Maryam [Department of Pedodontics, Golestan University of Medical Sciences, Gorgan (Iran, Islamic Republic of); Hosseinipanah, Mohammad [Department of Anatomy, School of Medicine, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Fardmal, Javad [Research Center for Health Sciences and Department of Epidemiology and Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of)

    2016-01-15

    Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog’s teeth. Forty eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans. (author)

  18. Near real-time imaging of molasses injections using time-lapse electrical geophysics at the Brandywine DRMO, Brandywine, Maryland

    Science.gov (United States)

    Versteeg, R. J.; Johnson, T.; Major, B.; Day-Lewis, F. D.; Lane, J. W.

    2010-12-01

    Enhanced bioremediation, which involves introduction of amendments to promote biodegradation, increasingly is used to accelerate cleanup of recalcitrant compounds and has been identified as the preferred remedial treatment at many contaminated sites. Although blind introduction of amendments can lead to sub-optimal or ineffective remediation, the distribution of amendment throughout the treatment zone is difficult to measure using conventional sampling. Because amendments and their degradation products commonly have electrical properties that differ from those of ambient soil, time-lapse electrical geophysical monitoring has the potential to verify amendment emplacement and distribution. In order for geophysical monitoring to be useful, however, results of the injection ideally should be accessible in near real time. In August 2010, we demonstrated the feasibility of near real-time, autonomous electrical geophysical monitoring of amendment injections at the former Defense Reutilization and Marketing Office (DRMO) in Brandywine, Maryland. Two injections of about 1000 gallons each of molasses, a widely used amendment for enhanced bioremediation, were monitored using measurements taken with borehole and surface electrodes. During the injections, multi-channel resistance data were recorded; data were transmitted to a server and processed using a parallel resistivity inversion code; and results in the form of time-lapse imagery subsequently were posted to a website. This process occurred automatically without human intervention. The resulting time-lapse imagery clearly showed the evolution of the molasses plume. The delay between measurements and online delivery of images was between 45 and 60 minutes, thus providing actionable information that could support decisions about field procedures and a check on whether amendment reached target zones. This experiment demonstrates the feasibility of using electrical imaging as a monitoring tool both during amendment emplacement

  19. Spatiotemporal monitoring of soil water content profiles in an irrigated field using probabilistic inversion of time-lapse EMI data

    KAUST Repository

    Moghadas, Davood

    2017-10-17

    Monitoring spatiotemporal variations of soil water content (θ) is important across a range of research fields, including agricultural engineering, hydrology, meteorology and climatology. Low frequency electromagnetic induction (EMI) systems have proven to be useful tools in mapping soil apparent electrical conductivity (σa) and soil moisture. However, obtaining depth profile water content is an area that has not been fully explored using EMI. To examine this, we performed time-lapse EMI measurements using a CMD mini-Explorer sensor along a 10 m transect of a maize field over a 6 day period. Reference data were measured at the end of the profile via an excavated pit using 5TE capacitance sensors. In order to derive a time-lapse, depth-specific subsurface image of electrical conductivity (σ), we applied a probabilistic sampling approach, DREAM(ZS), on the measured EMI data. The inversely estimated σ values were subsequently converted to θ using the Rhoades et al. (1976) petrophysical relationship. The uncertainties in measured σa, as well as inaccuracies in the inverted data, introduced some discrepancies between estimated σ and reference values in time and space. Moreover, the disparity between the measurement footprints of the 5TE and CMD Mini-Explorer sensors also led to differences. The obtained θ permitted an accurate monitoring of the spatiotemporal distribution and variation of soil water content due to root water uptake and evaporation. The proposed EMI measurement and modeling technique also allowed for detecting temporal root zone soil moisture variations. The time-lapse θ monitoring approach developed using DREAM(ZS) thus appears to be a useful technique to understand spatiotemporal patterns of soil water content and provide insights into linked soil moisture vegetation processes and the dynamics of soil moisture/infiltration processes.

  20. Spatiotemporal monitoring of soil water content profiles in an irrigated field using probabilistic inversion of time-lapse EMI data

    Science.gov (United States)

    Moghadas, Davood; Jadoon, Khan Zaib; McCabe, Matthew F.

    2017-12-01

    Monitoring spatiotemporal variations of soil water content (θ) is important across a range of research fields, including agricultural engineering, hydrology, meteorology and climatology. Low frequency electromagnetic induction (EMI) systems have proven to be useful tools in mapping soil apparent electrical conductivity (σa) and soil moisture. However, obtaining depth profile water content is an area that has not been fully explored using EMI. To examine this, we performed time-lapse EMI measurements using a CMD mini-Explorer sensor along a 10 m transect of a maize field over a 6 day period. Reference data were measured at the end of the profile via an excavated pit using 5TE capacitance sensors. In order to derive a time-lapse, depth-specific subsurface image of electrical conductivity (σ), we applied a probabilistic sampling approach, DREAM(ZS) , on the measured EMI data. The inversely estimated σ values were subsequently converted to θ using the Rhoades et al. (1976) petrophysical relationship. The uncertainties in measured σa, as well as inaccuracies in the inverted data, introduced some discrepancies between estimated σ and reference values in time and space. Moreover, the disparity between the measurement footprints of the 5TE and CMD Mini-Explorer sensors also led to differences. The obtained θ permitted an accurate monitoring of the spatiotemporal distribution and variation of soil water content due to root water uptake and evaporation. The proposed EMI measurement and modeling technique also allowed for detecting temporal root zone soil moisture variations. The time-lapse θ monitoring approach developed using DREAM(ZS) thus appears to be a useful technique to understand spatiotemporal patterns of soil water content and provide insights into linked soil moisture vegetation processes and the dynamics of soil moisture/infiltration processes.

  1. Effect of time lapse on the diagnostic accuracy of cone beam computed tomography for detection of vertical root fractures

    International Nuclear Information System (INIS)

    Eskandarloo, Amir; Shokri, Abbas; Asl, Amin Mahdavi; Jalalzadeh, Mohsen; Tayari, Maryam; Hosseinipanah, Mohammad; Fardmal, Javad

    2016-01-01

    Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog’s teeth. Forty eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans. (author)

  2. A multimethod Global Sensitivity Analysis to aid the calibration of geomechanical models via time-lapse seismic data

    Science.gov (United States)

    Price, D. C.; Angus, D. A.; Garcia, A.; Fisher, Q. J.; Parsons, S.; Kato, J.

    2018-03-01

    Time-lapse seismic attributes are used extensively in the history matching of production simulator models. However, although proven to contain information regarding production induced stress change, it is typically only loosely (i.e. qualitatively) used to calibrate geomechanical models. In this study we conduct a multimethod Global Sensitivity Analysis (GSA) to assess the feasibility and aid the quantitative calibration of geomechanical models via near-offset time-lapse seismic data. Specifically, the calibration of mechanical properties of the overburden. Via the GSA, we analyse the near-offset overburden seismic traveltimes from over 4000 perturbations of a Finite Element (FE) geomechanical model of a typical High Pressure High Temperature (HPHT) reservoir in the North Sea. We find that, out of an initially large set of material properties, the near-offset overburden traveltimes are primarily affected by Young's modulus and the effective stress (i.e. Biot) coefficient. The unexpected significance of the Biot coefficient highlights the importance of modelling fluid flow and pore pressure outside of the reservoir. The FE model is complex and highly nonlinear. Multiple combinations of model parameters can yield equally possible model realizations. Consequently, numerical calibration via a large number of random model perturbations is unfeasible. However, the significant differences in traveltime results suggest that more sophisticated calibration methods could potentially be feasible for finding numerous suitable solutions. The results of the time-varying GSA demonstrate how acquiring multiple vintages of time-lapse seismic data can be advantageous. However, they also suggest that significant overburden near-offset seismic time-shifts, useful for model calibration, may take up to 3 yrs after the start of production to manifest. Due to the nonlinearity of the model behaviour, similar uncertainty in the reservoir mechanical properties appears to influence overburden

  3. Spatiotemporal monitoring of soil water content profiles in an irrigated field using probabilistic inversion of time-lapse EMI data

    KAUST Repository

    Moghadas, Davood; Jadoon, Khan Zaib; McCabe, Matthew

    2017-01-01

    Monitoring spatiotemporal variations of soil water content (θ) is important across a range of research fields, including agricultural engineering, hydrology, meteorology and climatology. Low frequency electromagnetic induction (EMI) systems have proven to be useful tools in mapping soil apparent electrical conductivity (σa) and soil moisture. However, obtaining depth profile water content is an area that has not been fully explored using EMI. To examine this, we performed time-lapse EMI measurements using a CMD mini-Explorer sensor along a 10 m transect of a maize field over a 6 day period. Reference data were measured at the end of the profile via an excavated pit using 5TE capacitance sensors. In order to derive a time-lapse, depth-specific subsurface image of electrical conductivity (σ), we applied a probabilistic sampling approach, DREAM(ZS), on the measured EMI data. The inversely estimated σ values were subsequently converted to θ using the Rhoades et al. (1976) petrophysical relationship. The uncertainties in measured σa, as well as inaccuracies in the inverted data, introduced some discrepancies between estimated σ and reference values in time and space. Moreover, the disparity between the measurement footprints of the 5TE and CMD Mini-Explorer sensors also led to differences. The obtained θ permitted an accurate monitoring of the spatiotemporal distribution and variation of soil water content due to root water uptake and evaporation. The proposed EMI measurement and modeling technique also allowed for detecting temporal root zone soil moisture variations. The time-lapse θ monitoring approach developed using DREAM(ZS) thus appears to be a useful technique to understand spatiotemporal patterns of soil water content and provide insights into linked soil moisture vegetation processes and the dynamics of soil moisture/infiltration processes.

  4. Analysis of Zebrafish Kidney Development with Time-lapse Imaging Using a Dissecting Microscope Equipped for Optical Sectioning.

    Science.gov (United States)

    Perner, Birgit; Schnerwitzki, Danny; Graf, Michael; Englert, Christoph

    2016-04-07

    In order to understand organogenesis, the spatial and temporal alterations that occur during development of tissues need to be recorded. The method described here allows time-lapse analysis of normal and impaired kidney development in zebrafish embryos by using a fluorescence dissecting microscope equipped for structured illumination and z-stack acquisition. To visualize nephrogenesis, transgenic zebrafish (Tg(wt1b:GFP)) with fluorescently labeled kidney structures were used. Renal defects were triggered by injection of an antisense morpholino oligonucleotide against the Wilms tumor gene wt1a, a factor known to be crucial for kidney development. The advantage of the experimental setup is the combination of a zoom microscope with simple strategies for re-adjusting movements in x, y or z direction without additional equipment. To circumvent focal drift that is induced by temperature variations and mechanical vibrations, an autofocus strategy was applied instead of utilizing a usually required environmental chamber. In order to re-adjust the positional changes due to a xy-drift, imaging chambers with imprinted relocation grids were employed. In comparison to more complex setups for time-lapse recording with optical sectioning such as confocal laser scanning or light sheet microscopes, a zoom microscope is easy to handle. Besides, it offers dissecting microscope-specific benefits such as high depth of field and an extended working distance. The method to study organogenesis presented here can also be used with fluorescence stereo microscopes not capable of optical sectioning. Although limited for high-throughput, this technique offers an alternative to more complex equipment that is normally used for time-lapse recording of developing tissues and organ dynamics.

  5. The Potential Impact of Biofield Treatment on Human Brain Tumor Cells: A Time-Lapse Video Microscopy

    OpenAIRE

    Trivedi, Mahendra

    2015-01-01

    Study background: Glioblastoma (GBM) is the most common subtype of primary brain tumor in adults. The aim was to evaluate the impact of biofield treatment potential on human GBM and non-GBM brain cells using two time-lapse video microscopy technique. Methods: The human brain tumor, GBM cultured cells were divided into two groups viz. GBM control and GBM treatment. Similarly, human normal brain cultured cells (non-GBM) were taken and divided into two groups viz. non- GBM control and non-GB...

  6. A Dynamic Programming Model for Optimizing Frequency of Time-Lapse Seismic Monitoring in Geological CO2 Storage

    Science.gov (United States)

    Bhattacharjya, D.; Mukerji, T.; Mascarenhas, O.; Weyant, J.

    2005-12-01

    Designing a cost-effective and reliable monitoring program is crucial to the success of any geological CO2 storage project. Effective design entails determining both, the optimal measurement modality, as well as the frequency of monitoring the site. Time-lapse seismic provides the best spatial coverage and resolution for reservoir monitoring. Initial results from Sleipner (Norway) have demonstrated effective monitoring of CO2 plume movement. However, time-lapse seismic is an expensive monitoring technique especially over the long term life of a storage project and should be used judiciously. We present a mathematical model based on dynamic programming that can be used to estimate site-specific optimal frequency of time-lapse surveys. The dynamics of the CO2 sequestration process are simplified and modeled as a four state Markov process with transition probabilities. The states are M: injected CO2 safely migrating within the target zone; L: leakage from the target zone to the adjacent geosphere; R: safe migration after recovery from leakage state; and S: seepage from geosphere to the biosphere. The states are observed only when a monitoring survey is performed. We assume that the system may go to state S only from state L. We also assume that once observed to be in state L, remedial measures are always taken to bring it back to state R. Remediation benefits are captured by calculating the expected penalty if CO2 seeped into the biosphere. There is a trade-off between the conflicting objectives of minimum discounted costs of performing the next time-lapse survey and minimum risk of seepage and its associated costly consequences. A survey performed earlier would spot the leakage earlier. Remediation methods would have been utilized earlier, resulting in savings in costs attributed to excessive seepage. On the other hand, there are also costs for the survey and remedial measures. The problem is solved numerically using Bellman's optimality principal of dynamic

  7. 3D time-lapse analysis of Rab11/FIP5 complex: spatiotemporal dynamics during apical lumen formation.

    Science.gov (United States)

    Mangan, Anthony; Prekeris, Rytis

    2015-01-01

    Fluorescent imaging of fixed cells grown in two-dimensional (2D) cultures is one of the most widely used techniques for observing protein localization and distribution within cells. Although this technique can also be applied to polarized epithelial cells that form three-dimensional (3D) cysts when grown in a Matrigel matrix suspension, there are still significant limitations in imaging cells fixed at a particular point in time. Here, we describe the use of 3D time-lapse imaging of live cells to observe the dynamics of apical membrane initiation site (AMIS) formation and lumen expansion in polarized epithelial cells.

  8. A measurement technique for counting processes

    International Nuclear Information System (INIS)

    Cantoni, V.; Pavia Univ.; De Lotto, I.; Valenziano, F.

    1980-01-01

    A technique for the estimation of first and second order properties of a stationary counting process is presented here which uses standard instruments for analysis of a continuous stationary random signal. (orig.)

  9. Why calories count: from science to politics

    National Research Council Canada - National Science Library

    Nestle, Marion; Nesheim, Malden C

    2012-01-01

    .... They are also hard to understand. In Why Calories Count, Marion Nestle and Malden Nesheim explain in clear and accessible language what calories are and how they work, both biologically and politically...

  10. CoC Housing Inventory Count Reports

    Data.gov (United States)

    Department of Housing and Urban Development — Continuum of Care (CoC) Homeless Assistance Programs Housing Inventory Count Reports are a snapshot of a CoC’s housing inventory, available at the national and state...

  11. White Blood Cell Counts and Malaria

    National Research Council Canada - National Science Library

    McKenzie, F. E; Prudhomme, Wendy A; Magill, Alan J; Forney, J. R; Permpanich, Barnyen; Lucas, Carmen; Gasser, Jr., Robert A; Wongsrichanalai, Chansuda

    2005-01-01

    White blood cells (WBCs) were counted in 4697 individuals who presented to outpatient malaria clinics in Maesod, Tak Province, Thailand, and Iquitos, Peru, between 28 May and 28 August 1998 and between 17 May and 9 July 1999...

  12. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  13. Low white blood cell count and cancer

    Science.gov (United States)

    ... gov/ency/patientinstructions/000675.htm Low white blood cell count and cancer To use the sharing features on this page, please enable JavaScript. White blood cells (WBCs) fight infections from bacteria, viruses, fungi, and ...

  14. Regression Models For Multivariate Count Data.

    Science.gov (United States)

    Zhang, Yiwen; Zhou, Hua; Zhou, Jin; Sun, Wei

    2017-01-01

    Data with multivariate count responses frequently occur in modern applications. The commonly used multinomial-logit model is limiting due to its restrictive mean-variance structure. For instance, analyzing count data from the recent RNA-seq technology by the multinomial-logit model leads to serious errors in hypothesis testing. The ubiquity of over-dispersion and complicated correlation structures among multivariate counts calls for more flexible regression models. In this article, we study some generalized linear models that incorporate various correlation structures among the counts. Current literature lacks a treatment of these models, partly due to the fact that they do not belong to the natural exponential family. We study the estimation, testing, and variable selection for these models in a unifying framework. The regression models are compared on both synthetic and real RNA-seq data.

  15. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  16. Atom counting with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kutschera, Walter

    1995-01-01

    A brief review of the current status and some recent applications of accelerator mass spectrometry (AMS) are presented. Some connections to resonance ionization mass spectroscopy (RIS) as the alternate atom counting method are discussed

  17. Characterization for capillary barriers effects in a sand box test using time-lapsed GPR measurements

    Science.gov (United States)

    Kuroda, S.; Ishii, N.; Morii, T.

    2017-12-01

    Capillary barriers have been known as the method to protect subsurface regions against infiltration from soil surface. It is caused by essentially heterogeneous structure in permeability or soil physical property and produce non-uniform infiltration process then, in order to estimate the actual situation of the capillary barrier effect, the site-characterization with imaging technique like geophysical prospecting is effective. In this study, we examine the applicability of GPR to characterization for capillary barriers. We built a sand box with 90x340x90cm in which a thin high-permeable gravel layer was embedded as a capillary barrier. We conducted an infiltration test in the sand box using porous tube array for irrigation. It is expected to lead to non-uniform flow of soil water induced by capillary barrier effects. We monitored this process by various types of GPR measurements, including time-lapsed common offset profiling (COP) with multi- frequency antenna and transmission measurements like cross-borehole radar. At first, we conducted GPR common-offset survey. It could show the depth of capillary barrier in sand box. After that we conducted the infiltration test and GPR monitoring for infiltration process. GPR profiles can detect the wetting front and estimate water content change in the soil layer above the capillary barrier. From spatial change in these results we can estimate the effect of capillary barrier and the zone where the break through occur or not. Based on these results, we will discuss the applicability of GPR for monitoring the phenomena around the capillary barrier of soil. At first, we conducted GPR common-offset survey. It could show the depth of capillary barrier in sand box. After that we conducted the infiltration test and GPR monitoring for infiltration process. GPR profiles can detect the wetting front and estimate water content change in the soil layer above the capillary barrier. From spatial change in these results we can estimate the

  18. A Novel Methodology for Characterizing Cell Subpopulations in Automated Time-lapse Microscopy

    Directory of Open Access Journals (Sweden)

    Georges Hattab

    2018-02-01

    Full Text Available Time-lapse imaging of cell colonies in microfluidic chambers provides time series of bioimages, i.e., biomovies. They show the behavior of cells over time under controlled conditions. One of the main remaining bottlenecks in this area of research is the analysis of experimental data and the extraction of cell growth characteristics, such as lineage information. The extraction of the cell line by human observers is time-consuming and error-prone. Previously proposed methods often fail because of their reliance on the accurate detection of a single cell, which is not possible for high density, high diversity of cell shapes and numbers, and high-resolution images with high noise. Our task is to characterize subpopulations in biomovies. In order to shift the analysis of the data from individual cell level to cellular groups with similar fluorescence or even subpopulations, we propose to represent the cells by two new abstractions: the particle and the patch. We use a three-step framework: preprocessing, particle tracking, and construction of the patch lineage. First, preprocessing improves the signal-to-noise ratio and spatially aligns the biomovie frames. Second, cell sampling is performed by assuming particles, which represent a part of a cell, cell or group of contiguous cells in space. Particle analysis includes the following: particle tracking, trajectory linking, filtering, and color information, respectively. Particle tracking consists of following the spatiotemporal position of a particle and gives rise to coherent particle trajectories over time. Typical tracking problems may occur (e.g., appearance or disappearance of cells, spurious artifacts. They are effectively processed using trajectory linking and filtering. Third, the construction of the patch lineage consists in joining particle trajectories that share common attributes (i.e., proximity and fluorescence intensity and feature common ancestry. This step is based on patch finding

  19. A Modular and Affordable Time-Lapse Imaging and Incubation System Based on 3D-Printed Parts, a Smartphone, and Off-The-Shelf Electronics.

    Science.gov (United States)

    Hernández Vera, Rodrigo; Schwan, Emil; Fatsis-Kavalopoulos, Nikos; Kreuger, Johan

    2016-01-01

    Time-lapse imaging is a powerful tool for studying cellular dynamics and cell behavior over long periods of time to acquire detailed functional information. However, commercially available time-lapse imaging systems are expensive and this has limited a broader implementation of this technique in low-resource environments. Further, the availability of time-lapse imaging systems often present workflow bottlenecks in well-funded institutions. To address these limitations we have designed a modular and affordable time-lapse imaging and incubation system (ATLIS). The ATLIS enables the transformation of simple inverted microscopes into live cell imaging systems using custom-designed 3D-printed parts, a smartphone, and off-the-shelf electronic components. We demonstrate that the ATLIS provides stable environmental conditions to support normal cell behavior during live imaging experiments in both traditional and evaporation-sensitive microfluidic cell culture systems. Thus, the system presented here has the potential to increase the accessibility of time-lapse microscopy of living cells for the wider research community.

  20. A Modular and Affordable Time-Lapse Imaging and Incubation System Based on 3D-Printed Parts, a Smartphone, and Off-The-Shelf Electronics

    Science.gov (United States)

    Schwan, Emil; Fatsis-Kavalopoulos, Nikos; Kreuger, Johan

    2016-01-01

    Time-lapse imaging is a powerful tool for studying cellular dynamics and cell behavior over long periods of time to acquire detailed functional information. However, commercially available time-lapse imaging systems are expensive and this has limited a broader implementation of this technique in low-resource environments. Further, the availability of time-lapse imaging systems often present workflow bottlenecks in well-funded institutions. To address these limitations we have designed a modular and affordable time-lapse imaging and incubation system (ATLIS). The ATLIS enables the transformation of simple inverted microscopes into live cell imaging systems using custom-designed 3D-printed parts, a smartphone, and off-the-shelf electronic components. We demonstrate that the ATLIS provides stable environmental conditions to support normal cell behavior during live imaging experiments in both traditional and evaporation-sensitive microfluidic cell culture systems. Thus, the system presented here has the potential to increase the accessibility of time-lapse microscopy of living cells for the wider research community. PMID:28002463

  1. Highway driving safety the day after using sleep medication: the direction of lapses and excursions out-of-lane in drowsy drivers.

    Science.gov (United States)

    Verster, Joris C; Mooren, Loes; Bervoets, Adriana C; Roth, Thomas

    2017-10-24

    The primary outcome measure of the on-road driving test is the Standard Deviation of Lateral Position. However, other outcome measures, such as lapses and excursions out-of-lane, also need to be considered as they may be related to crash risk. The aim of this study was to determine the direction of lapses and excursions out-of-lane (i.e. towards/into the adjacent traffic lane or towards/into the road shoulder). In total, data from 240 driving tests were re-analysed, and 628 lapses and 401 excursions out-of-lane were identified. The analyses revealed that lapses were made equally frequently over left (49.4%) and over right (43.3%). In contrast, excursions out-of-lane were almost exclusively directed over right into the (safer) road shoulder (97.3%). These findings suggest that drivers are unaware of having lapses, whereas excursions out-of-lane are events where the driver is aware of loss of vehicle control. © 2017 The Authors. Journal of Sleep Research published by John Wiley & Sons Ltd on behalf of European Sleep Research Society.

  2. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  3. How to count an introduction to combinatorics

    CERN Document Server

    Allenby, RBJT

    2010-01-01

    What's It All About? What Is Combinatorics? Classic Problems What You Need to Know Are You Sitting Comfortably? Permutations and Combinations The Combinatorial Approach Permutations CombinationsApplications to Probability Problems The Multinomial Theorem Permutations and Cycles Occupancy Problems Counting the Solutions of Equations New Problems from Old A ""Reduction"" Theorem for the Stirling Numbers The Inclusion-Exclusion Principle Double Counting Derangements A Formula for the Stirling NumbersStirling and Catalan Numbers Stirling Numbers Permutations and Stirling Numbers Catalan Numbers Pa

  4. Accuracy and precision in activation analysis: counting

    International Nuclear Information System (INIS)

    Becker, D.A.

    1974-01-01

    Accuracy and precision in activation analysis was investigated with regard to counting of induced radioactivity. The various parameters discussed include configuration, positioning, density, homogeneity, intensity, radioisotopic purity, peak integration, and nuclear constants. Experimental results are presented for many of these parameters. The results obtained indicate that counting errors often contribute significantly to the inaccuracy and imprecision of analyses. The magnitude of these errors range from less than 1 percent to 10 percent or more in many cases

  5. Remote system for counting of nuclear pulses

    International Nuclear Information System (INIS)

    Nieves V, J.A.; Garcia H, J.M.; Aguilar B, M.A.

    1999-01-01

    In this work, it is describe technically the remote system for counting of nuclear pulses, an integral system of the project radiological monitoring in a petroleum distillation tower. The system acquires the counting of incident nuclear particles in a nuclear detector which process this information and send it in serial form, using the RS-485 toward a remote receiver, which can be a Personal computer or any other device capable to interpret the communication protocol. (Author)

  6. Recursive algorithms for phylogenetic tree counting.

    Science.gov (United States)

    Gavryushkina, Alexandra; Welch, David; Drummond, Alexei J

    2013-10-28

    In Bayesian phylogenetic inference we are interested in distributions over a space of trees. The number of trees in a tree space is an important characteristic of the space and is useful for specifying prior distributions. When all samples come from the same time point and no prior information available on divergence times, the tree counting problem is easy. However, when fossil evidence is used in the inference to constrain the tree or data are sampled serially, new tree spaces arise and counting the number of trees is more difficult. We describe an algorithm that is polynomial in the number of sampled individuals for counting of resolutions of a constraint tree assuming that the number of constraints is fixed. We generalise this algorithm to counting resolutions of a fully ranked constraint tree. We describe a quadratic algorithm for counting the number of possible fully ranked trees on n sampled individuals. We introduce a new type of tree, called a fully ranked tree with sampled ancestors, and describe a cubic time algorithm for counting the number of such trees on n sampled individuals. These algorithms should be employed for Bayesian Markov chain Monte Carlo inference when fossil data are included or data are serially sampled.

  7. Preverbal and verbal counting and computation.

    Science.gov (United States)

    Gallistel, C R; Gelman, R

    1992-08-01

    We describe the preverbal system of counting and arithmetic reasoning revealed by experiments on numerical representations in animals. In this system, numerosities are represented by magnitudes, which are rapidly but inaccurately generated by the Meck and Church (1983) preverbal counting mechanism. We suggest the following. (1) The preverbal counting mechanism is the source of the implicit principles that guide the acquisition of verbal counting. (2) The preverbal system of arithmetic computation provides the framework for the assimilation of the verbal system. (3) Learning to count involves, in part, learning a mapping from the preverbal numerical magnitudes to the verbal and written number symbols and the inverse mappings from these symbols to the preverbal magnitudes. (4) Subitizing is the use of the preverbal counting process and the mapping from the resulting magnitudes to number words in order to generate rapidly the number words for small numerosities. (5) The retrieval of the number facts, which plays a central role in verbal computation, is mediated via the inverse mappings from verbal and written numbers to the preverbal magnitudes and the use of these magnitudes to find the appropriate cells in tabular arrangements of the answers. (6) This model of the fact retrieval process accounts for the salient features of the reaction time differences and error patterns revealed by experiments on mental arithmetic. (7) The application of verbal and written computational algorithms goes on in parallel with, and is to some extent guided by, preverbal computations, both in the child and in the adult.

  8. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  9. Examining the information content of time-lapse crosshole GPR data collected under different infiltration conditions to estimate unsaturated soil hydraulic properties

    DEFF Research Database (Denmark)

    Scholer, M.; Irving, J.; Zibar, Majken Caroline Looms

    2013-01-01

    Time-lapse geophysical data acquired during transient hydrological experiments are being increasingly employed to estimate subsurface hydraulic properties at the field scale. In particular, crosshole ground-penetrating radar (GPR) data, collected while water infiltrates into the subsurface either...... by natural or artificial means, have been demonstrated in a number of studies to contain valuable information concerning the hydraulic properties of the unsaturated zone. Previous work in this domain has considered a variety of infiltration conditions and different amounts of time-lapse GPR data...... of time-lapse zero-offset-profile (ZOP) GPR traveltime data, collected under three different infiltration conditions, for the estimation of van Genuchten–Mualem (VGM) parameters in a layered subsurface medium. Specifically, we systematically analyze synthetic and field GPR data acquired under natural...

  10. Blunted striatal response to monetary reward anticipation during smoking abstinence predicts lapse during a contingency-managed quit attempt.

    Science.gov (United States)

    Sweitzer, Maggie M; Geier, Charles F; Denlinger, Rachel; Forbes, Erika E; Raiff, Bethany R; Dallery, Jesse; McClernon, F J; Donny, Eric C

    2016-03-01

    Tobacco smoking is associated with dysregulated reward processing within the striatum, characterized by hypersensitivity to smoking rewards and hyposensitivity to non-smoking rewards. This bias toward smoking reward at the expense of alternative rewards is further exacerbated by deprivation from smoking, which may contribute to difficulty maintaining abstinence during a quit attempt. We examined whether abstinence-induced changes in striatal processing of rewards predicted lapse likelihood during a quit attempt supported by contingency management (CM), in which abstinence from smoking was reinforced with money. Thirty-six non-treatment-seeking smokers participated in two functional MRI (fMRI) sessions, one following 24-h abstinence and one following smoking as usual. During each scan, participants completed a rewarded guessing task designed to elicit striatal activation in which they could earn smoking and monetary rewards delivered after the scan. Participants then engaged in a 3-week CM-supported quit attempt. As previously reported, 24-h abstinence was associated with increased striatal activation in anticipation of smoking reward and decreased activation in anticipation of monetary reward. Individuals exhibiting greater decrements in right striatal activation to monetary reward during abstinence (controlling for activation during non-abstinence) were more likely to lapse during CM (p reward. These results are consistent with a growing number of studies indicating the specific importance of disrupted striatal processing of non-drug reward in nicotine dependence and highlight the importance of individual differences in abstinence-induced deficits in striatal function for smoking cessation.

  11. Determination of residual oil saturation from time-lapse pulsed neutron capture logs in a large sandstone reservoir

    International Nuclear Information System (INIS)

    Syed, E.V.; Salaita, G.N.; McCaffery, F.G.

    1991-01-01

    Cased hole logging with pulsed neutron tools finds extensive use for identifying zones of water breakthrough and monitoring oil-water contacts in oil reservoirs being depleted by waterflooding or natural water drive. Results of such surveys then find direct use for planning recompletions and water shutoff treatments. Pulsed neutron capture (PNC) logs are useful for estimating water saturation changes behind casing in the presence of a constant, high-salinity environment. PNC log surveys run at different times, i.e., in a time-lapse mode, are particularly amenable to quantitative analysis. The combined use of the original open hole and PNC time-lapse log information can then provide information on remaining or residual oil saturations in a reservoir. This paper reports analyses of historical pulsed neutron capture log data to assess residual oil saturation in naturally water-swept zones for selected wells from a large sandstone reservoir in the Middle East. Quantitative determination of oil saturations was aided by PNC log information obtained from a series of tests conducted in a new well in the same field

  12. MitoGen: A Framework for Generating 3D Synthetic Time-Lapse Sequences of Cell Populations in Fluorescence Microscopy.

    Science.gov (United States)

    Svoboda, David; Ulman, Vladimir

    2017-01-01

    The proper analysis of biological microscopy images is an important and complex task. Therefore, it requires verification of all steps involved in the process, including image segmentation and tracking algorithms. It is generally better to verify algorithms with computer-generated ground truth datasets, which, compared to manually annotated data, nowadays have reached high quality and can be produced in large quantities even for 3D time-lapse image sequences. Here, we propose a novel framework, called MitoGen, which is capable of generating ground truth datasets with fully 3D time-lapse sequences of synthetic fluorescence-stained cell populations. MitoGen shows biologically justified cell motility, shape and texture changes as well as cell divisions. Standard fluorescence microscopy phenomena such as photobleaching, blur with real point spread function (PSF), and several types of noise, are simulated to obtain realistic images. The MitoGen framework is scalable in both space and time. MitoGen generates visually plausible data that shows good agreement with real data in terms of image descriptors and mean square displacement (MSD) trajectory analysis. Additionally, it is also shown in this paper that four publicly available segmentation and tracking algorithms exhibit similar performance on both real and MitoGen-generated data. The implementation of MitoGen is freely available.

  13. Estimation of soil hydraulic parameters by integrated hydrogeophysical inversion of time-lapse GPR data measured at Selhausen, Germany

    KAUST Repository

    Jadoon, Khan

    2012-06-01

    We present an integrated hydrogeophysical inversion approach that uses time-lapse off-ground ground-penetrating radar (GPR) data to estimate soil hydraulic parameters, and apply it to a dataset collected in the field. Off-ground GPR data are mainly sensitive to the near-surface water content profile and dynamics, and are thus related to soil hydraulic parameters, such as the parameters of the hydraulic conductivity and water retention functions. The hydrological simulator HYDRUS 1-D was used with a two-layer single- and dual-porosity model. To monitor the soil water content dynamics, time-lapse GPR and time domain reflectometry (TDR) measurements were performed, whereby only GPR data was used in the inversion. The dual porosity model provided better results compared to the single porosity model for describing the soil water dynamics, which is supported by field observations of macropores. Furthermore, the GPR-derived water content profiles reconstructed from the integrated hydrogeophysical inversion were in good agreement with TDR observations. These results suggest that the proposed method is promising for non-invasive characterization of the shallow subsurface hydraulic properties and monitoring water dynamics at the field scale.

  14. Medical students' experiences of professional lapses and patient rights abuses in a South African health sciences faculty.

    Science.gov (United States)

    Vivian, Lauraine M H; Naidu, Claudia S; Keikelame, Mpoe J; Irlam, James

    2011-10-01

    To elicit South African medical students' experiences of witnessing patient rights abuses and professional lapses during their clinical training in order to inform an appropriate and effective response. During June and July 2009 at the University of Cape Town Faculty of Health Sciences, the authors surveyed 223 fourth-, fifth-, and sixth-year medical students in selected clinical rotations concerning abuses they had observed. Volunteers were later interviewed individually. The authors coded interview transcripts for key themes using a constant-comparative grounded theory approach. Of 223 students surveyed, 183 (82%) responded, 130 (71%) of whom reported witnessing patient rights abuses and professional lapses, including physical abuse (38%), verbal abuse (37%), disrespect for patients' dignity (25%), and inadequately informing patients about their treatment (25%). Students attributed abuse to stressed health workers, overburdened facilities, and disempowered patients. Most students who witnessed abuse (59%) did not actively respond, and 64% of survey respondents felt unprepared or uncertain about challenging abuses in the future. Interviews with 28 students yielded detailed accounts of the abuses witnessed and of students' emotional reactions, coping strategies, and responses. Most students did not report abuses; they feared reprisal or doubted it would make a difference. This study demonstrates the disjunction between what these students were taught about human rights and ethics and what they witnessed in clinical settings. The high prevalence of patient rights abuses experienced by these students highlights the need to align medical ethics and human rights with medico-legal protocols in theory and clinical practice.

  15. A comparison of the cytotoxic activity of eosinophils and other cells by 51chromium release and time lapse microcinematography

    International Nuclear Information System (INIS)

    Sanderson, C.J.; Thomas, J.A.

    1978-01-01

    Antibody dependent cytotoxicity of chicken erythrocytes by purified rat eosinophils, neutrophils, macrophages and K cells has been compared by 51 Cr release and time lapse microcinematography. Techniques have been developed for purifying these effector cell types. Both eosinophils and neutrophils caused rapid release of 51 Cr from erythrocytes. Time lapse observations indicated that this was the result of phagocytosis. Eosinophils showed rapid membrane movement and repeatedly engulfed and regurgitated the erythrocytes. On the other hand, neutrophils became quiescent after phagocytosing erythrocytes, and remained quiescent until the remains of the cell were expelled. Neutrophils presumably have a mechanism for the release of soluble material, as 51 Cr was released rapidly. Macrophages showed a similar quiescence after phagocytosis, but in these cells there was apparently no rapid mechanism to expel material, as there was no significant 51 Cr release over 20 h. K cells appeared to damage chicken erythrocytes more slowly than they destroyed tumour cells. Mast cells caused antibody-independent cytotoxicity which can be attributed to the release of toxic materials. None of these effector cells produced the type of lysis seen with antibody and complement. (author)

  16. Photon counting and fluctuation of molecular movement

    International Nuclear Information System (INIS)

    Inohara, Koichi

    1978-01-01

    The direct measurement of the fluctuation of molecular motions, which provides with useful information on the molecular movement, was conducted by introducing photon counting method. The utilization of photon counting makes it possible to treat the molecular system consisting of a small number of molecules like a radioisotope in the detection of a small number of atoms, which are significant in biological systems. This method is based on counting the number of photons of the definite polarization emitted in a definite time interval from the fluorescent molecules excited by pulsed light, which are bound to the marked large molecules found in a definite spatial region. Using the probability of finding a number of molecules oriented in a definite direction in the definite spatial region, the probability of counting a number of photons in a definite time interval can be calculated. Thus the measurable count rate of photons can be related with the fluctuation of molecular movement. The measurement was carried out under the condition, in which the probability of the simultaneous arrival of more than two photons at a detector is less than 1/100. As the experimental results, the resolving power of photon-counting apparatus, the frequency distribution of the number of photons of some definite polarization counted for 1 nanosecond are shown. In the solution, the variance of the number of molecules of 500 on the average is 1200, which was estimated from the experimental data by assuming normal distribution. This departure from the Poisson distribution means that a certain correlation does exist in molecular movement. In solid solution, no significant deviation was observed. The correlation existing in molecular movement can be expressed in terms of the fluctuation of the number of molecules. (Nakai, Y.)

  17. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  18. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  19. Financial Barriers and Lapses in Treatment and Care of HIV-Infected Adults in a Southern State in the United States.

    Science.gov (United States)

    Wohl, David A; Kuwahara, Rita K; Javadi, Kamran; Kirby, Christine; Rosen, David L; Napravnik, Sonia; Farel, Claire

    2017-11-01

    Antiretroviral (ARV) adherence has largely been considered from the perspective of an individual's behavior with less attention given to potential structural causes for lapses in treatment, such as the cost of medications and care. HIV medication expense is typically covered by third party payers. However, private insurance premiums and deductibles may rise, or policies terminated such as with a change in employment. Likewise, a patient's eligibility for publicly funded coverage like state AIDS Drug Assistance Programs (ADAP) or Medicaid can also be lost. We conducted a one-time survey of a sample of 300 patients receiving HIV care at a single large academic center in the south of United States to examine lapses in HIV therapy due to financial reasons. We found that during the prior year, financial issues including medication cost or coverage led to a lapse in ARVs in 10% (n = 31) of participants. However, of the 42% (n = 125) participants who had been enrolled in ADAP at any time during the prior year, 21% (n = 26) reported an ARV lapse due to problems with ADAP or medication cost. Respondents cited ADAP's required semi-annual renewal process and other administrative issues as the cause of ARV lapses. The median duration of missed ARVs was 2 weeks (range of financial burdens to care by respondents. In conclusion, although conducted at a single medical center and one state, this study suggests that a significant minority of HIV-infected patients encounter financial barriers to ARV access, and this is paradoxically more common among those enrolled in the state ADAP. Streamlining, supporting, and simplifying ADAP renewal procedures will likely reduce lapses in ARV adherence and persistence.

  20. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  1. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  2. Protecting count queries in study design.

    Science.gov (United States)

    Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.

  3. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  4. Intense dust episodes in the Mediterranean and possible effects on atmospheric lapse rates

    Science.gov (United States)

    Hatzianastassiou, Nikos; Gkikas, Antonis; Papadimas, Christos D.; Gavrouzou, Maria

    2016-04-01

    Dust aerosols are major contributor to the atmospheric particulate matter, having significant effects on climate and weather patterns as well as on human health, not to mention others like agriculture or ocean chlorophyll. Moreover, these effects are maximized under conditions of massive dust concentration in the atmosphere, namely dust episodes or events. Such events are caused by uplifting and transport of dust from arid and semi-arid areas under favorable synoptic conditions. The Mediterranean basin, nearby to the greatest world deserts of North Africa and Middle East, frequently undergoes dust episodes. During such Mediterranean episodes, the number and mass concentration of dust is high, due to the proximity of its source areas. The dust episodes, through the direct interaction of dust primarily withthe shortwave but also with longwave radiation can lead to strong local warming in the atmosphere, possibly causing temperature inversion during daytime. The existence of such temperature inversions, associated with intense dust episodes in the Mediterranean, is the focus in this study. The methodology followed to achieve the scientific goal of the study consists in the use of a synergy of different data. This synergy enables: (i) the determination of intense dust episodes over the Mediterranean, (ii) the investigation and specification of temperature lapse rates and inversions during the days of dust episodes and (iii) the identification of vertical distribution of aerosols in the atmosphere over specific locations during the days of the episodes. These objectives are achieved through the use of data from: (i) the AERosol Robotic NETwork (AERONET) network, (ii) the Upper Air Observations (radiosondes) database of the University of Wyoming (UoW) and (iii) the European Aerosol Research Lidar Network (EARLINET) database. The study period spans the years from 2000 to 2013, constrained by the data availability of the databases. A key element of the methodology is the

  5. BMI in relation to sperm count

    DEFF Research Database (Denmark)

    Sermondade, N; Faure, C; Fezeu, L

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review...... with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men...... studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm...

  6. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count

  7. CERN_DxCTA counting mode chip

    CERN Document Server

    Moraes, D; Nygård, E

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e−, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  8. CERNDxCTA counting mode chip

    International Nuclear Information System (INIS)

    Moraes, D.; Kaplon, J.; Nygard, E.

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e - , for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors

  9. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  10. Pharmacy refill adherence compared with CD4 count changes for monitoring HIV-infected adults on antiretroviral therapy.

    Directory of Open Access Journals (Sweden)

    Gregory P Bisson

    2008-05-01

    Full Text Available World Health Organization (WHO guidelines for monitoring HIV-infected individuals taking combination antiretroviral therapy (cART in resource-limited settings recommend using CD4(+ T cell (CD4 count changes to monitor treatment effectiveness. In practice, however, falling CD4 counts are a consequence, rather than a cause, of virologic failure. Adherence lapses precede virologic failure and, unlike CD4 counts, data on adherence are immediately available to all clinics dispensing cART. However, the accuracy of adherence assessments for predicting future or detecting current virologic failure has not been determined. The goal of this study therefore was to determine the accuracy of adherence assessments for predicting and detecting virologic failure and to compare the accuracy of adherence-based monitoring approaches with approaches monitoring CD4 count changes.We conducted an observational cohort study among 1,982 of 4,984 (40% HIV-infected adults initiating non-nucleoside reverse transcriptase inhibitor-based cART in the Aid for AIDS Disease Management Program, which serves nine countries in southern Africa. Pharmacy refill adherence was calculated as the number of months of cART claims submitted divided by the number of complete months between cART initiation and the last refill prior to the endpoint of interest, expressed as a percentage. The main outcome measure was virologic failure defined as a viral load > 1,000 copies/ml (1 at an initial assessment either 6 or 12 mo after cART initiation and (2 after a previous undetectable (i.e., 0.5. In addition, adherence levels assessed 3 mo prior to viral load assessments were as accurate for virologic failure occurring approximately 3 mo later as were CD4 count changes calculated from cART initiation to the actual time of the viral load assessments, indicating the potential utility of adherence assessments for predicting future, rather than simply detecting current, virologic failure. Moreover

  11. Effects of plutonium redistribution on lung counting

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1976-01-01

    Early counts of Pu deposition in lungs will tend to overestimate lung contents since calibrations are performed with a uniform distribution and since a more favorable geometry exists in contaminated subjects because the activity is closer to the periphery of the lungs. Although the concentration into the outer regions of the lungs continues as evidenced by the autopsy studies, the counts performed by L X-rays will probably underestimate the lung content; because, simplistically, the geometry several years after exposure consists of a spherical shell with a point of activity in the center. This point of activity represents concentration in the lymph nodes from which the 60 keV gamma of 241 Am will be counted, but from which few of the L X-rays will be counted (this is an example of interorgan distribution). When a correction is made to the L X-ray intensity, the lymph node contribution will tend to increase the amount subtracted while correcting for 241 Am X-rays. It is doubtful that the relative increase in X-ray intensity by concentration in the pleural and sub-pleural regions will compensate for this effect. This will make the plutonium burden disappear while the 241 Am can still be detected. This effect has been observed in a case where counts with an intraesophageal probe indicated a substantial lymph node burden. In order to improve the accuracy of in vivo plutonium measurements, an improved understanding of pulmonary distribution and of distribution effects on in vivo counting are required

  12. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  13. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  14. Counting dyons in N=4 string theory

    CERN Document Server

    Dijkgraaf, R; Verlinde, Herman L

    1997-01-01

    We present a microscopic index formula for the degeneracy of dyons in four-dimensional N=4 string theory. This counting formula is manifestly symmetric under the duality group, and its asymptotic growth reproduces the macroscopic Bekenstein-Hawking entropy. We give a derivation of this result in terms of the type II five-brane compactified on K3, by assuming that its fluctuations are described by a closed string theory on its world-volume. We find that the degeneracies are given in terms of the denominator of a generalized super Kac-Moody algebra. We also discuss the correspondence of this result with the counting of D-brane states.

  15. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  16. Highlights from the SoilCAM project: Soil Contamination, Advanced integrated characterisation and time-lapse Monitoring

    Science.gov (United States)

    French, H. K.; van der Zee, S. E. A. T. M.; Wehrer, M.; Godio, A.; Pedersen, L. B.; Toscano, G.

    2012-04-01

    The SoilCAM project (Soil Contamination, Advanced integrated characterisation and time-lapse Monitoring 2008-2012, EU-FP7-212663) is aimed at improving current methods for monitoring contaminant distribution and biodegradation in the subsurface. At two test sites, Oslo airport Gardermoen in Norway and the Trecate site in Italy, a number of geophysical techniques, lysimeter and other soil and water sampling techniques as well as numerical flow and transport modelling have been combined at different scales in order to characterise flow transport processes in the unsaturated and saturated zones. Laboratory experiments have provided data on physical and bio-geo-chemical parameters for use in models and to select remediation methods. The geophysical techniques were used to map geological heterogeneities and also conduct time-lapse measurements of processes in the unsaturated zone. Both cross borehole and surface electrodes were used for electrical resistivity and induced polarisation surveys. The geophysical surveys showed clear indications of areas highly affected by de-icing chemicals along the runway at Oslo airport. The time lapse measurements along the runway at the airport show infiltration patterns during snowmelt and are used to validate 2D unsaturated flow and transport simulations using SUTRA. The Orchestra model is used to describe the complex interaction between bio-geo-chemical processes in a 1D profile along the runway. The presence of installations such as a membrane along the runway highly affects the flow pattern and challenges the capacity of the numerical code. Smaller scale field site measurements have revealed the increase of iron and manganese during degradation of de-icing chemicals. The use of Nitrate to increase red-ox potential was tested, but results have not been analysed yet. So far it cannot be concluded that degradation process can be quantified indirectly by geophysical monitoring. At the Trecate site a combination of georadar, electrical

  17. Separating climate change signals into thermodynamic, lapse-rate and circulation effects: theory and application to the European summer climate

    Science.gov (United States)

    Kröner, Nico; Kotlarski, Sven; Fischer, Erich; Lüthi, Daniel; Zubler, Elias; Schär, Christoph

    2017-05-01

    Climate models robustly project a strong overall summer warming across Europe showing a characteristic north-south gradient with enhanced warming and drying in southern Europe. However, the processes that are responsible for this pattern are not fully understood. We here employ an extended surrogate or pseudo-warming approach to disentangle the contribution of different mechanisms to this response pattern. The basic idea of the surrogate technique is to use a regional climate model and apply a large-scale warming to the lateral boundary conditions of a present-day reference simulation, while maintaining the relative humidity (and thus implicitly increasing the specific moisture content). In comparison to previous studies, our approach includes two important extensions: first, different vertical warming profiles are applied in order to separate the effects of a mean warming from lapse-rate effects. Second, a twin-design is used, in which the climate change signals are not only added to present-day conditions, but also subtracted from a scenario experiment. We demonstrate that these extensions provide an elegant way to separate the full climate change signal into contributions from large-scale thermodynamic (TD), lapse-rate (LR), and circulation and other remaining effects (CO). The latter in particular include changes in land-ocean contrast and spatial variations of the SST warming patterns. We find that the TD effect yields a large-scale warming across Europe with no distinct latitudinal gradient. The LR effect, which is quantified for the first time in our study, leads to a stronger warming and some drying in southern Europe. It explains about 50 % of the warming amplification over the Iberian Peninsula, thus demonstrating the important role of lapse-rate changes. The effect is linked to an extending Hadley circulation. The CO effect as inherited from the driving GCM is shown to further amplify the north-south temperature change gradient. In terms of mean summer

  18. Nevada Kids Count Data Book, 1997.

    Science.gov (United States)

    We Can, Inc., Las Vegas, NV.

    This Kids Count data book is the first to examine statewide indicators of the well being of Nevada's children. The statistical portrait is based on 15 indicators of child well being: (1) percent low birth-weight babies; (2) infant mortality rate; (3) percent of children in poverty; (4) percent of children in single-parent families; (5) percent of…

  19. Isospectral graphs with identical nodal counts

    International Nuclear Information System (INIS)

    Oren, Idan; Band, Ram

    2012-01-01

    According to a recent conjecture, isospectral objects have different nodal count sequences (Gnutzmann et al 2005 J. Phys. A: Math. Gen. 38 8921–33). We study generalized Laplacians on discrete graphs, and use them to construct the first non-trivial counterexamples to this conjecture. In addition, these examples demonstrate a surprising connection between isospectral discrete and quantum graphs. (paper)

  20. Phase-space quark counting rule

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Gin, Chao; Lo, Shui-Yin [Academia Sinica, Beijing (China). Inst. of High Energy Physics

    1981-05-21

    A simple quark counting rule based on the phase-space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter-free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions.