WorldWideScience

Sample records for pvpp cartridge treatment

  1. Adsorption of isoflavones onto PVPP in the presence of a soy matrix

    NARCIS (Netherlands)

    Jankowiak, Lena; Avermaete, Van Ivonne; Boom, Remko; Goot, Van Der Atze Jan

    2015-01-01

    The adsorption of isoflavones from an okara extract onto polyvinyl polypyrrolidone (PVPP) was studied for a pH ranging from 4 to 7. In general, the affinity of aglycones to PVPP was around 10 times higher than the affinity of the glycosides. Towards lower pH, the adsorption performance improved

  2. Towards a Kieselguhr- and PVPP-Free Clarification and Stabilization Process of Rough Beer at Room-Temperature Conditions.

    Science.gov (United States)

    Cimini, Alessio; Moresi, Mauro

    2018-01-01

    In this work, the main constraint (that is, beer chilling and chill haze removing) of the current beer conditioning techniques using Kieselguhr filtration and Polyvinylpolypyrrolidone (PVPP) treatment was overcome by developing a novel higher-throughput conditioning process, operating at room temperatures with no use of filter aids. The effect of filtration temperature (T F ) in the range of 0 to 40 °C on the hydraulic permeability of ceramic hollow-fiber (HF) membranes with nominal pore size of 0.2 to 1.4 μm, as well as on their limiting permeation flux (J * ) when feeding precentrifuged rough beer, was preliminarily assessed. When using the 1.4-μm HF membrane operating at T F ≥ 20 °C, it was possible to enhance the average permeation flux at values (676 to 1844 L/m 2 /h), noticeably higher than those (250 to 500 L/m 2 /h) characteristics of conventional powder filtration. Despite its acceptable permanent haze, the resulting beer permeate still exhibited colloidal instability. By resorting to the commercial enzyme preparation Brewers Clarex® before beer clarification, it was possible to significantly improve its colloidal stability as measured using a number of European Brewing Convention forcing tests, especially with respect to that of precentrifuged rough beer by itself. By combining the above enzymatic treatment with membrane clarification at 30 °C across the ceramic 1.4-μm HF membrane module, it was possible to limit the haze development due to chilling, sensitive proteins, and alcohol addition to as low as 0.78, 4.1, and 4.0 EBC-U, respectively, the enzymatic treatment being by far more effective than that using PVPP. A novel Kieselguhr- and PVPP-free rough beer conditioning process at room temperatures was set up. By submitting precentrifuged rough beer to commercial preparation Brewers Clarex ® and then to membrane clarification at 30 °C across a ceramic 1.4-μm hollow-fiber membrane module, it was possible to obtain a clear and stable beer with

  3. Difference in the Dissolution Behaviors of Tablets Containing Polyvinylpolypyrrolidone (PVPP) Depending on Pharmaceutical Formulation After Storage Under High Temperature and Humid Conditions.

    Science.gov (United States)

    Takekuma, Yoh; Ishizaka, Haruka; Sumi, Masato; Sato, Yuki; Sugawara, Mitsuru

    Storage under high temperature and humid conditions has been reported to decrease the dissolution rate for some kinds of tablets containing polyvinylpolypyrrolidone (PVPP) as a disintegrant. The aim of this study was to elucidate the properties of pharmaceutical formulations with PVPP that cause a decrease in the dissolution rate after storage under high temperature and humid conditions by using model tablets with a simple composition. Model tablets, which consisted of rosuvastatin calcium or 5 simple structure compounds, salicylic acid, 2-aminodiphenylmethane, 2-aminobiphenyl, 2-(p-tolyl)benzoic acid or 4.4'-biphenol as principal agents, cellulose, lactose hydrate, PVPP and magnesium stearate as additives, were made by direct compression. The model tables were wrapped in paraffin papers and stored for 2 weeks at 40°C/75% relative humidity (RH). Dissolution tests were carried out by the paddle method in the Japanese Pharmacopoeia 16th edition. Model tablets with a simple composition were able to reproduce a decreased dissolution rate after storage at 40°C/75% RH. These tablets showed significantly decreased water absorption activities after storage. In the case of tablets without lactose hydrate by replacing with cellulose, a decreased dissolution rate was not observed. Carboxyl and amino groups in the structure of the principal agent were not directly involved in the decreased dissolution. 2-Benzylaniline tablets showed a remarkably decreased dissolution rate and 2-aminobiphenyl and 2-(p-tolyl)benzoic acid tablets showed slightly decreased dissolution rates, though 4,4'-biphenol tablets did not show a decrease dissolution rate. We demonstrated that additives and structure of the principal agent were involved in the decreased in dissolution rate for tablets with PVPP. The results suggested that one of the reasons for a decreased dissolution rate was the inclusion of lactose hydrate in tablets. The results also indicated that compounds as principal agents with low

  4. The Indicating FTA Elute Cartridge

    Science.gov (United States)

    de Bie, Roosmarie P.; Schmeink, Channa E.; Bakkers, Judith M.J.E.; Snijders, Peter J.F.; Quint, Wim G.V.; Massuger, Leon F.A.G.; Bekkers, Ruud L.M.; Melchers, Willem J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. PMID:21704269

  5. Change in muzzle velocity due to freezing and water immersion of .22, long rifle, K.F. cartridges.

    Science.gov (United States)

    Jauhari, M; Chatterjee, S M; Ghosh, P K

    1975-01-01

    A study of change in muzzle velocity due to freezing and water immersion of .22, long rifle, K. F. cartridges has been presented. A statistical criterion has been formulated to ascertain whether or not a cartridge undergoes a change in muzzle velocity due to a particular treatment. The muzzle velocity data of .22, long rifle, K. F. cartridges, obtained by an electronic timer before and after the various treatments, have been analyzed in the light of this criterion. These cartridges have generally been found to suffer considerable loss in muzzle velocity when immersed in water for three weeks and also when immersed in water for three days and simultaneously cooled to 0 degrees C. The forensic significance of this loss in muzzle velocity has been discussed.

  6. Quick-change filter cartridge

    Science.gov (United States)

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  7. StorageTek T10000 Data Cartridge

    CERN Multimedia

    This data cartridge works on several StorageTek systems. The goal is to provide cartridge compatibility across several system. It has been designed for space saving and ultra-high capacity tape. It permit to fulfill high-volume backup, archiving, and disaster recovery.

  8. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  9. Adsorbent cartridge for the exhaust of diazo process machines

    International Nuclear Information System (INIS)

    Michlin, N.; Thies, E.J.

    1982-01-01

    A disposable cartridge filled with a chemical composition that acts as an adsorbent for ammonia vapor is adapted to be used in connection with a diazo process printing machine having a vacuum exhausted chamber. Exhaust from the chamber is passed through the cartridge to remove the noxious ammonia vapors and then is vented into the atmosphere. The cartridge is housed in an elongated rectangular cardboard box having three end flaps formed at each of its opposed open ends. Two opposed flaps of each set are formed with central holes and a plastic screen section adhered between these flaps to retain and allow access to the center section of the box which contains the adsorbent chemical. The center end flaps have knock-outs or tear strips that allow holes to be formed in their centers. These center end flaps cover the screens during shipment and when the cartridge is ready for use the center sections of these end flaps are knocked-out to allow the machine exhaust to be vented into and out of the cartridge

  10. Criticality safety evaluation report for K Basin filter cartridges

    International Nuclear Information System (INIS)

    Schwinkendorf, K.N.

    1995-01-01

    A criticality safety evaluation of the K Basin filter cartridge assemblies has been completed to support operations without a criticality alarm system. The results show that for normal operation, the filter cartridge assembly is far below the safety limit of k eff = 0.95, which is applied to plutonium systems at the Hanford Site. During normal operating conditions, uranium, plutonium, and fission and corrosion products in solution are continually accumulating in the available void spaces inside the filter cartridge medium. Currently, filter cartridge assemblies are scheduled to be replaced at six month intervals in KE Basin, and at one year intervals in KW Basin. According to available plutonium concentration data for KE Basin and data for the U/Pu ratio, it will take many times the six-month replacement time for sufficient fissionable material accumulation to take place to exceed the safety limit of k eff = 0.95, especially given the conservative assumption that the presence of fission and corrosion products is ignored. Accumulation of sludge with a composition typical of that measured in the sand filter backwash pit will not lead to a k eff = 0.95 value. For off-normal scenarios, it would require at least two unlikely, independent, and concurrent events to take place before the k eff = 0.95 limit was exceeded. Contingencies considered include failure to replace the filter cartridge assemblies at the scheduled time resulting in additional buildup of fissionable material, the loss of geometry control from the filter cartridge assembly breaking apart and releasing the individual filter cartridges into an optimal configuration, and concentrations of plutonium at U/Pu ratios less than measured data for KE Basin, typically close to 400 according to extensive measurements in the sand filter backwash pit and plutonium production information

  11. StorageTek T10000 Tape Cartridge

    CERN Multimedia

    1985-01-01

    Oracle StorageTek T10000T2 cartridge has total capacity of 5 TB. It is actually manufactured by Fuji Film, uses Barium Ferrite (BaFe) particles technology data store, but is also equipped with RFID chip. There is over 1 km of tape inside of the cartridge with 3584 data tracks and it supports over 25000 load/unload cycles. The archival life is estimated to be around 30 years and uncorrected bit error rate is 10-19. CERN however usually migrates data to newer technologies roughly every 5 years in order to keep the footprint under control.

  12. Alterations in a Unique Class of Cortical Chandelier Cell Axon Cartridges in Schizophrenia.

    Science.gov (United States)

    Rocco, Brad R; DeDionisio, Adam M; Lewis, David A; Fish, Kenneth N

    2017-07-01

    The axons of chandelier cells (ChCs) target the axon initial segment of pyramidal neurons, forming an array of boutons termed a cartridge. In schizophrenia, the density of cartridges detectable by gamma-aminobutyric acid (GABA) membrane transporter 1 immunoreactivity is lower, whereas the density of axon initial segments detectable by immunoreactivity for the α2 subunit of the GABA A receptor is higher in layers 2/superficial 3 of the prefrontal cortex. These findings were interpreted as compensatory responses to lower GABA levels in ChCs. However, we recently found that in schizophrenia, ChC cartridge boutons contain normal levels of the 67 kDa isoform of glutamic acid decarboxylase (GAD67) protein, the enzyme responsible for GABA synthesis in these boutons. To understand these findings we quantified the densities of ChC cartridges immunoreactive for vesicular GABA transporter (vGAT+), which is present in all cartridge boutons, and the subset of cartridges that contain calbindin (CB+). Prefrontal cortex tissue sections from 20 matched pairs of schizophrenia and unaffected comparison subjects were immunolabeled for vGAT, GAD67, and CB. The mean density of vGAT+/CB+ cartridges was 2.7-fold higher, exclusively in layer 2 of schizophrenia subjects, whereas the density of vGAT+/CB- cartridges did not differ between subject groups. Neither vGAT, CB, or GAD67 protein levels per ChC bouton nor the number of boutons per cartridge differed between subject groups. Our findings of a greater density of CB+ ChC cartridges in prefrontal cortex layer 2 from schizophrenia subjects suggests that the normal developmental pruning of these cartridges is blunted in the illness. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  13. Thermal analysis with expendable cartridge

    International Nuclear Information System (INIS)

    Susaki, K.; Landgraf, F.J.G.

    1981-01-01

    The pratical method of thermal analysis with expendable cartridge and some aspects of its use are presented. The results of the method applied to the system Nb-Mn are presented together with data from microprobe. (Author) [pt

  14. Evaluation and comparison of a national made dental cartridge with two foreign made

    Directory of Open Access Journals (Sweden)

    Mahmood Hashemi H

    2006-06-01

    Full Text Available Background and Aim: Several factories produce dental cartridge in the world. In Iran, Daroupakhsh company is responsible for this task. The aim of this study was evaluate some properties of daroupakhsh cartridge and compare them with two imported ones: Ecocaine (made in Italy and Septodont (made in France. Materials and Methods: In this experimental study, 70 healthy patients from maxillofacial clinic of Shariaty hospital were selected. After obtaining informed consent, 0.1 cc of each carpule was injected to the patients' frontal region and the extent of anesthesia was measured at different time intervals. Also the quality of injections was evaluated by 11 surgeons. The dimensions of the three cartridges were also measured and compared together. Data were analyzed by repeated measure ANOVA and Friedman with p<0.05 as the limit of significance. Results: There was no significant difference in extent and duration of anesthesia among the studied cartridges. Surgeons were equally satisfied of all three kinds of cartridges. All of the cartridges were aspirable. Conclusion: Based on the results of this study, the three studied cartridges had similar properties.

  15. 42 CFR 84.194 - Filters used with chemical cartridges; location; replacement.

    Science.gov (United States)

    2010-10-01

    ...; replacement. 84.194 Section 84.194 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN...; replacement. (a) Particulate matter filters used in conjunction with a chemical cartridge shall be located on... replacement on the cartridge. ...

  16. Hazard classification test of the cartridge, 120-mm, APFSDS-T, XM829

    Energy Technology Data Exchange (ETDEWEB)

    Hooker, C.D.; Hadlock, D.E.; Mishima, J.; Gilchrist, R.L.

    1983-11-01

    Research was conducted to determine the behavior of the ammunition XM829 when subjected to detonation of an adjacent XM829 cartridge, and a sustained hot fire. It was concluded that the functioning of an XM829 cartridge, in one shipping container, will not cause immediate functioning of XM829 cartridges in adjacent containers. However, if a fire results and is sustained, adjacent cartridges may ignite, resulting in some scattering of debris within a maximum radius of 40 feet. Further, the XM829 cartridge can be expected to remain in a kinetic controlled regime with vigorous oxidation occurring early in such a fire but dropping off as the temperature cools toward ambient. Mass balance analyses data indicated a recovery of at least 80% in the 1982 external heat; in the 1983 test, the recovery percentage was improved to approximately 100% of the original depleted uranium weight volume. Therefore, it may be concluded that a significant airborne release of the depleted uranium material did not occur.

  17. Treatment with different fining agents of white musts from spoiled wine grapes

    Directory of Open Access Journals (Sweden)

    Eric Meistermann

    2018-03-01

    Full Text Available Fining agents have evolved significantly over the last twenty years. The need for winemakers to have objective references about the new products has prompted this study. The experiment consists in comparing the new fining products (charcoal, pea proteins, derivatives of chitin and composite products generally mixing PVPP + various proteins + bentonite with reference products such as casein and PVPP and with non-treated controls. Fining agents were applied during clarification of 15 different musts obtained from wine grapes affected by different degrees and types of rot: fresh and dry Botrytis cinerea rot, powdery mildew and Botrytis contaminated with other fungi (Aspergillus, Penicillium, Basidiomycetes, giving the bunches offflavours that were earthy and resembled fresh mushrooms. This study highlights the importance of good clarification of musts. The quality of control wines, without any treatment, increases with the clarity of the must. In most experiments, clarification of the must around 50 Nephelometric Turbidity Units (NTU can eliminate or reduce any organoleptic defects in wine without fining. Use of pectolytic enzymes may be necessary in order to reach this level of clarity. The new allergen-free fining agents have the same effectiveness as reference products such as casein and polyvinylpolypyrolidone (PVPP. Composite products are more efficient than pea protein alone and less than products including charcoal. However, the improvement of aromatic quality goes hand in hand with loss of body and persistence.

  18. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  19. Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

    International Nuclear Information System (INIS)

    2015-01-01

    The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institute (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: 108m Ag, 110m Ag, 60 Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)

  20. Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-07-01

    The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institute (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: {sup 108m}Ag, {sup 110m}Ag, {sup 60}Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)

  1. Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge

    Science.gov (United States)

    Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; deMello, Andrew

    2015-07-01

    Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.

  2. Investigation of effective forensic cleaning methods for bullet and cartridge case samples

    Science.gov (United States)

    Shuherk, Cassie Marie

    Bullet and cartridge case evidence may potentially link weapons and crimes through the comparison of toolmark patterns. This analysis relies on the clarity of the toolmarks and the ability of the examiner to identify patterns on the evidence. These patterns may be distorted by debris such as soil, blood, cyanoacrylate, and construction materials. Despite the potential importance of bullet and cartridge case evidence, few investigations of proper cleaning methods have been conducted. The present study was designed to examine the effects of various cleaning solutions and application methods on copper and brass bullets and cartridge cases. Additionally, this research investigated the efficacy of these cleaning protocols on the common evidence contaminants blood and cyanoacrylate. No cleaning method was found to be universally effective on both contaminant types and nondestructive to the metal surface. Ultrasonication was the most efficient application method employed when used in conjunction with an appropriate cleaning solution. Acetone proved to be safe and successful at removing heavy cyanoacrylate deposits from brass cartridge cases without damaging the metal. Although sulfuric acid removed most of the cyanoacrylate from the brass cartridge case, ultrasonication of the fumed cartridge cases in sulfuric acid caused the nickel-plated primer caps to turn black. Additionally, etching occurred when sulfuric acid was allowed to dry on the cartridge case surface. Citric acid, salt-flour-vinegar paste, TergazymeRTM, and water did not effectively remove the cyanoacrylate from the cartridge cases, but the solutions were safe to use on the brass and sometimes resulted in a shinier surface. Regardless of the cleaning method employed, the bloodstained bullets retained most or all of the underlying brown tarnish. Ultrasonication with sulfuric acid was successful at removing some blood-initiated tarnishing; however, the removal of residues was not complete, making it difficult

  3. 42 CFR 84.1155 - Filters used with canisters and cartridges; location; replacement.

    Science.gov (United States)

    2010-10-01

    ...; location; replacement. 84.1155 Section 84.1155 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... Efficiency Respirators and Combination Gas Masks § 84.1155 Filters used with canisters and cartridges; location; replacement. (a) Particulate matter filters used in conjunction with a canister or cartridge...

  4. Microfluidic cartridges for DNA purification and genotyping processed in standard laboratory instruments

    Science.gov (United States)

    Focke, Maximilian; Mark, Daniel; Stumpf, Fabian; Müller, Martina; Roth, Günter; Zengerle, Roland; von Stetten, Felix

    2011-06-01

    Two microfluidic cartridges intended for upgrading standard laboratory instruments with automated liquid handling capability by use of centrifugal forces are presented. The first microfluidic cartridge enables purification of DNA from human whole blood and is operated in a standard laboratory centrifuge. The second microfluidic catridge enables genotyping of pathogens by geometrically multiplexed real-time PCR. It is operated in a slightly modified off-the-shelf thermal cycler. Both solutions aim at smart and cost-efficient ways to automate work flows in laboratories. The DNA purification cartridge automates all liquid handling steps starting from a lysed blood sample to PCR ready DNA. The cartridge contains two manually crushable glass ampoules with liquid reagents. The DNA yield extracted from a 32 μl blood sample is 192 +/- 30 ng which corresponds to 53 +/- 8% of a reference extraction. The genotyping cartridge is applied to analyse isolates of the multi-resistant Staphyloccus aureus (MRSA) by real-time PCR. The wells contain pre-stored dry reagents such as primers and probes. Evaluation of the system with 44 genotyping assays showed a 100% specificity and agreement with the reference assays in standard tubes. The lower limit of detection was well below 10 copies of DNA per reaction.

  5. A self-contained fully-enclosed microfluidic cartridge for lab on a chip.

    Science.gov (United States)

    Yobas, Levent; Cheow, Lih Feng; Tang, Kum-Cheong; Yong, Shien-Eit; Ong, Eleana Kye-Zheng; Wong, Lionel; Teo, William Cheng-Yong; Ji, Hongmiao; Rafeah, Siti; Yu, Chen

    2009-12-01

    We describe a self-contained fully-enclosed cartridge for lab-on-a-chip applications where sample and reagents can be applied sequentially as is performed in a heterogeneous immunoassay, or nucleic acid extraction. Both the self-contained and fully-enclosed features of the cartridge are sought to ensure its safe use in the field by unskilled staff. Simplicity in cartridge design and operation is obtained via adopting a valveless concept whereby reagents are stored and used in the form of liquid plugs isolated by air spacers around a fluidic loop. Functional components integrated in the loop include a microfluidic chip specific to the target application, a novel peristaltic pump to displace the liquid plugs, and a pair of removable tubing segments where one is used to introduce biological sample and while the other is to collect eluant. The novel pump is fabricated through soft-lithography technique and works by pinching a planar channel under stainless-steel ball bearings that have been magnetically loaded. The utility of the cartridge is demonstrated for automated extraction and purification of nucleic acids (DNA) from a cell lysate on a battery-operated portable system. The cartridge shown here can be further extended to sample-in-answer-out diagnostic tests.

  6. Development of a Rapid and Simple Method to Remove Polyphenols from Plant Extracts

    Directory of Open Access Journals (Sweden)

    Imali Ranatunge

    2017-01-01

    Full Text Available Polyphenols are secondary metabolites of plants, which are responsible for prevention of many diseases. Polyvinylpolypyrrolidone (PVPP has a high affinity towards polyphenols. This method involves the use of PVPP column to remove polyphenols under centrifugal force. Standards of gallic acid, epigallocatechin gallate, vanillin, and tea extracts (Camellia sinensis were used in this study. PVPP powder was packed in a syringe with different quantities. The test samples were layered over the PVPP column and subjected to centrifugation. Supernatant was tested for the total phenol content. The presence of phenolic compounds and caffeine was screened by HPLC and measuring the absorbance at 280. The antioxidant capacity of standards and tea extracts was compared with the polyphenol removed fractions using DPPH scavenging assay. No polyphenols were found in polyphenolic standards or tea extracts after PVPP treatment. The method described in the present study to remove polyphenols is simple, inexpensive, rapid, and efficient and can be employed to investigate the contribution of polyphenols present in natural products to their biological activity.

  7. The reactor Phenix - cartridge rupture detection

    International Nuclear Information System (INIS)

    Graftieaux, J.

    1967-01-01

    This report defines the role of cartridge rupture detection in the reactor Phenix. It gives the possible methods, their probable performances, their advantages and disadvantages. The final form of the installation will be determined mainly by the degree of safety required, by the technical possibilities of the reactor design and by the operational flexibility wanted. (author) [fr

  8. The indicating FTA elute cartridge a solid sample carrier to detect high-risk HPV and high-grade cervical lesions

    NARCIS (Netherlands)

    Bie, R.P. de; Schmeink, C.E.; Bakkers, J.M.J.E.; Snijders, P.J.L.M.; Quint, W.G.V.; Massuger, L.F.A.G.; Bekkers, R.L.M.; Melchers, W.J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were

  9. Determining Service Life of Respirator Cartridges Using a Simple and Practical Method: Case Study in a Car Manufacturing Industry

    Directory of Open Access Journals (Sweden)

    A.M Rashidi

    2012-01-01

    Full Text Available Background and aims: For ensuring about proper performance of air-purifying respirators in providing protection against workplace contaminants, it is necessary to change the respirator cartridges before the end of their service life. The aim of this study was determination of service life of organic vapor cartridges using a simple and practical method in a spray painting booth of a car manufacturing industry.   Methods: NIOSH MultiVapor software was used for estimating service life of respirator cartridges based on workplace conditions and cartridge specifications. Efficiency of determined service life was investigated using an apparatus for field testing of cartridges in the workplace.   Results: The results showed that existing schedule for changing the respirator cartridges is not effective and no longer provide adequate protection for sprayers against organic contaminants while working in a painting booth. It is necessary to change the cartridges before their estimated service life (every 4 hours.   Conclusion: NIOSH MultiVapor has acceptable efficiency for determining respirator cartridges service life and could be used as a simple and practical method in the workplace. Moreover, Service life estimated by this software was confirmed by cartridge field test apparatus.

  10. CONSTRUCTION AND OPTIMISATION OF A CARTRIDGE FILTER ...

    African Journals Online (AJOL)

    a

    1Department of Chemistry, Egerton University, P.O. Box 356, Njoro, Kenya .... the resident time in the filter, thus there is not enough time for F- to interact with the ... associated with creation of too much backpressure in the cartridge as well as ...

  11. Batch fabrication of polymer microfluidic cartridges for QCM sensor packaging by direct bonding

    Science.gov (United States)

    Sandström, Niklas; Zandi Shafagh, Reza; Gylfason, Kristinn B.; Haraldsson, Tommy; van der Wijngaart, Wouter

    2017-12-01

    Quartz crystal microbalance (QCM) sensing is an established technique commonly used in laboratory based life-science applications. However, the relatively complex, multi-part design and multi-step fabrication and assembly of state-of-the-art QCM cartridges make them unsuited for disposable applications such as point-of-care (PoC) diagnostics. In this work, we present the uncomplicated manufacturing of QCMs in polymer microfluidic cartridges. Our novel approach comprises two key innovations: the batch reaction injection molding of microfluidic parts; and the integration of the cartridge components by direct, unassisted bonding. We demonstrate molding of batches of 12 off-stoichiometry thiol-ene epoxy polymer (OSTE+) polymer parts in a single molding cycle using an adapted reaction injection molding process; and the direct bonding of the OSTE+  parts to other OSTE+  substrates, to printed circuit boards, and to QCMs. The microfluidic QCM OSTE+  cartridges were successfully evaluated in terms of liquid sealing as well as electrical properties, and the sensor performance characteristics are on par with those of a commercially available QCM biosensor cartridge. The simplified manufacturing of QCM sensors with maintained performance potentializes novel application areas, e.g. as disposable devices in a point of care setting. Moreover, our results can be extended to simplifying the fabrication of other microfluidic devices with multiple heterogeneously integrated components.

  12. The isolation of water-soluble radionuclides from deteriorating spent nuclear fuel in zeolite cartridge

    International Nuclear Information System (INIS)

    Hassan, N.M.; Thompson, M.C.

    1996-01-01

    A method of isolating water-soluble radionuclides leaching from deteriorating spent nuclear fuel by ion-exchange in zeolite cartridges has been studied. Design calculations of two zeolite cartridges to be incorporated in typical spent fuel storage bundle have been provided. Equilibrium exchange data obtained at several temperatures have shown that the maximum exchange capacity of total cesium in sodium titanium aluminosilicate was 114 mg/g zeolite and the capacity at 95% exchange for radioactive isotope Cs-137 was calculated as 55.2 mg/g zeolite. The kinetic data suggest that the rate of exchange of Cs + in sodium titanium aluminosilicate zeolite takes place by a fast initial exchange step followed by slow diffusion of cesium cations. Design calculations based on the equilibrium exchange data show that water-soluble radionuclides leaching from Mk 31 slugs can be isolated using two zeolite cartridges, each 3.7 inches in inside diameter and 2.5 inches in length. The cartridges are designed to isolate 95% of the Cs + leaching from the spent fuel storage bundle. The results from the thermal induced convective flow tests indicate that the system will provide necessary cooling to the spent fuel by convective currents while isolating the Cs + leaching from spent fuel storage bundle in the cartridges

  13. Simplified quality control of radioactive seeds in sterile cartridge for prostate brachytherapy using an imaging plate and a collimator

    International Nuclear Information System (INIS)

    Saze, T.; Miyoshi, H.; Maezawa, H.; Kubota, M.; Furutani, S.; Nishitani, H.; Kawaguchi, Y.; Nakayama, S.; Ito, S.; Nishizawa, K.

    2008-01-01

    Image analyzer system and collimator has been successfully applied to calibrate simultaneously multiple 125 I seeds in a sterile cartridge. Seeds within the cartridge were placed on an imaging plate, and the imaging plate irradiated. To remove scatter radiation, and improve spatial resolution of seed images, this study used a specially designed collimator. The irradiated imaging plate was scanned using an image analyzer system, and radioactivity intensities of seed images were given in counts. Counts could be translated to profiles, and each seed within the cartridge was analyzed. It is observed that a good correlation between counts and total radioactivity of the seeds within the cartridge. Thus, using a least-squares line, it was possible to calibrate a seed with unknown apparent activity. By analyzing the profiles, it was possible not only to detect a mis calibrated seed in the cartridge from its relative difference in counts, but also to identify its position in the cartridge. Using an imaging analyzer system, all seeds in a cartridge could be calibrated in a sterile environment. (author)

  14. Characterization of the water filters cartridges from the iea-r1 reactor using the Monte Carlo method

    International Nuclear Information System (INIS)

    Costa, Priscila; Potiens Junior, Ademar J.

    2015-01-01

    Filter cartridges are part of the primary water treatment system of the IEA-R1 Research Reactor and, when saturated, they are replaced and become radioactive waste. The IEA-R1 is located at the Nuclear and Energy Research Institute (IPEN), in Sao Paulo, Brazil. The primary characterization is the main step of the radioactive waste management in which the physical, chemical and radiological properties are determined. It is a very important step because the information obtained in this moment enables the choice of the appropriate management process and the definition of final disposal options. In this paper, it is presented a non-destructive method for primary characterization, using the Monte Carlo method associated with the gamma spectrometry. Gamma spectrometry allows the identification of radionuclides and their activity values. The detection efficiency is an important parameter, which is related to the photon energy, detector geometry and the matrix of the sample to be analyzed. Due to the difficult to obtain a standard source with the same geometry of the filter cartridge, another technique is necessary to calibrate the detector. The technique described in this paper uses the Monte Carlo method for primary characterization of the IEA-R1 filter cartridges. (author)

  15. Validation of a cartridge method for the quality control determination of 99Tcm-HMPAO

    International Nuclear Information System (INIS)

    Pandos, G.; Penglis, S.; Tsopelas, C.; Royal Adelaide Hospital, Adelaide, SA

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of ±-HMPAO requires the use of three solvent types on two different stationary phases, and is time-consuming (∼ 15 min) in consideration of the short shelf-life (30 min). An impetus to develop a rapid quality control procedure for this product has led to the use of a single strip Whatman 17 chromatography system using ethyl acetate as the developing solvent. This popular Whatman paper system was previously validates against the manufacturer's method. We have developed a new method to successfully determine the % RCP of ±-HMPAO, which employs a disposable, inexpensive and reusable Amprep C-18 cartridge with normal saline as a non-organic mobile phase. The Whatman paper system separates the primary lipophilic 99 Tc m -HMPAO complex from 99 Tc m O-2, 99 Tc m O 4 and secondary 99 Tc m -HMPAO complex at the origin. By comparison, the lipophilic portion was retained on the cartridge and the hydrophilic impurities were found in saline eluent with the cartridge method. Whatman 17 paper system results showed 95.1 ± I.7% 99 Tc m -HMPAO after 5 min and the cartridge method gave 95.5 ± 1.5% 99 Tc m -HMPAO (n = 8) after 3 min. The % 99 Tc m O 2 levels in 99 Tc m -HMPAO were insignificant. When a failed kit was assessed for RCP at 2.5 h post-reconstitution, the Whatman paper system and the cartridge method correlated well, resulting in 63.1 ± 2.7% and 62.9±2.1% 99 Tc m -HMPAO (n=3) respectively. Although the cartridge method may slightly overestimate the % RCP of 99 Tc m -HMPAO, it was found to be simple, rapid and reliable for the quality control analysis of routine 99 Tc m -HMPAO preparations

  16. Sensitivity analysis overlaps of friction elements in cartridge seals

    Directory of Open Access Journals (Sweden)

    Žmindák Milan

    2018-01-01

    Full Text Available Cartridge seals are self-contained units consisting of a shaft sleeve, seals, and gland plate. The applications of mechanical seals are numerous. The most common example of application is in bearing production for automobile industry. This paper deals with the sensitivity analysis of overlaps friction elements in cartridge seal and their influence on the friction torque sealing and compressive force. Furthermore, it describes materials for the manufacture of sealings, approaches usually used to solution of hyperelastic materials by FEM and short introduction into the topic wheel bearings. The practical part contains one of the approach for measurement friction torque, which results were used to specifying the methodology and precision of FEM calculation realized by software ANSYS WORKBENCH. This part also contains the sensitivity analysis of overlaps friction elements.

  17. Optimal stapler cartridge selection according to the thickness of the pancreas in distal pancreatectomy.

    Science.gov (United States)

    Kim, Hongbeom; Jang, Jin-Young; Son, Donghee; Lee, Seungyeoun; Han, Youngmin; Shin, Yong Chan; Kim, Jae Ri; Kwon, Wooil; Kim, Sun-Whe

    2016-08-01

    Stapling is a popular method for stump closure in distal pancreatectomy (DP). However, research on which cartridges are suitable for different pancreatic thickness is lacking. To identify the optimal stapler cartridge choice in DP according to pancreatic thickness.From November 2011 to April 2015, data were prospectively collected from 217 consecutive patients who underwent DP with 3-layer endoscopic staple closure in Seoul National University Hospital, Korea. Postoperative pancreatic fistula (POPF) was graded according to International Study Group on Pancreatic Fistula definitions. Staplers were grouped based on closed length (CL) (Group I: CL ≤ 1.5 mm, II: 1.5 mm 17 mm. With pancreatic thickness <12 mm, the POPF rate was lowest with Group II (I: 50%, II: 27.6%, III: 69.2%, P = 0.035).The optimal stapler cartridges with pancreatic thickness <12 mm were those in Group II (Gold, CL: 1.8 mm). There was no suitable cartridge for thicker pancreases. Further studies are necessary to reduce POPF in thick pancreases.

  18. Magazine Influence on Cartridge Case Ejection Patterns with Glock Pistols.

    Science.gov (United States)

    Kerkhoff, Wim; Alberink, Ivo; Mattijssen, Erwin J A T

    2018-01-01

    In this study, the cartridge case ejection patterns of six different Glock model pistols (one specimen per model) were compared under three conditions: firing with a loaded magazine, an empty magazine, and without magazine. The distances, covered by the ejected cartridge cases given these three conditions, were compared for each of the six models. A significant difference was found between the groups of data for each of the tested specimens. This indicates that it is important that, to reconstruct a shooting scene incident based on the ejection patterns of a pistol, test shots are fired with the same pistol type and under the correct magazine condition. © 2017 American Academy of Forensic Sciences.

  19. The indicating FTA elute cartridge a solid sample carrier to detect high-risk HPV and high-grade cervical lesions.

    Science.gov (United States)

    de Bie, Roosmarie P; Schmeink, Channa E; Bakkers, Judith M J E; Snijders, Peter J F; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2011-07-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  20. Rapid, efficient and selective preconcentration of benzo[a]pyrene (BaP) by molecularly imprinted composite cartridge and HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Çorman, Mehmet Emin, E-mail: mecorman@sinop.edu.tr [Hacettepe University, Department of Chemistry, Ankara (Turkey); Sinop University, Department of Bioengineering, Sinop (Turkey); Armutcu, Canan [Hacettepe University, Department of Chemistry, Ankara (Turkey); Uzun, Lokman, E-mail: lokman@hacettepe.edu.tr [Hacettepe University, Department of Chemistry, Ankara (Turkey); Denizli, Adil [Hacettepe University, Department of Chemistry, Ankara (Turkey)

    2017-01-01

    In this study, cryogel-based molecularly imprinted composite cartridges were designed for the rapid, efficient, and selective preconcentration of benzo[a]pyrene (BaP) from water samples. First, a BaP-imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-(L)-phenylalanine) composite cartridge was synthesized under semi-frozen conditions and characterized by scanning electron microscopy, elemental analysis, Fourier transform infrared spectroscopy, and swelling tests. After the optimization of preconcentration parameters, i.e., pH and initial BaP concentration, the selectivity and preconcentration efficiency, and reusability of these cartridges were also evaluated. In selectivity experiments, BaP imprinted composite cartridge exhibited binding capacities 3.09, 9.52, 8.87, and 8.77-fold higher than that of the non-imprinted composite cartridge in the presence of competitors, such as benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), indeno[1,2,3-cd]pyrene (IcdP), and 1-naphthol, respectively. The method detection limit (MDL), relative standard deviation (RSD) and preconcentration efficiency (PE) of the synthesized composite cartridge were calculated as 24.86 μg/L, 1.60%, and 349.6%, respectively. - Highlights: • Cryogel based molecularly imprinted composite cartridges as solid-phase extraction sorbents • Combination unique structural features of cryogels with MIP • An excellent ability to recognize the BaP molecule even if single-run contact • Rapid, efficient, selective and cost-friendly PAH preconcentration • Hydrophobic interactions via N-methacryloyl-(L)-phenylalanine.

  1. Synthesis of O-(2-[18F]fluoroethyl)-L-tyrosine based on a cartridge purification method

    International Nuclear Information System (INIS)

    Mueller, Dirk; Klette, Ingo; Kalb, Fabrizia; Baum, Richard P.

    2011-01-01

    Introduction: O-(2-[ 18 F]fluoroethyl)-L-tyrosine (FET) is widely used as a positron emission tomography tracer for brain tumors. Usually, a high-performance liquid chromatography (HPLC) purification at the end of the two-step synthesis is applied. In this work, we report an automatic radiosynthesis of FET with a purification procedure based on standard cartridges. Methods: O-(2-[ 18 F]fluoroethyl)-L-tyrosine was prepared by [ 18 F]fluoroethylation of L-tyrosine by a two-step synthesis using a modified [ 11 C]methionine module (Nuclear Interface). In the first reaction step, we synthesized [ 18 F]fluoroethyltosylate starting from [ 18 F]fluoride. After a purification step, L-tyrosine was [ 18 F]fluoroethylated with [ 18 F]fluoroethyltosylate. The final reaction mixture was purified by means of solid phase extraction. The FET was trapped on an SCX cartridge, eluted with saline solution and trapped again on an HRX cartridge. For a second purification step, the FET was eluted from the HRX cartridge with ammonium acetate buffer and collected on two SCX cartridges followed by a washing step with water. The final product was eluted with saline solution and neutralised with 450 μl NaHCO 3 solution (8.4%). Results: The synthesis was finished after 50 min and delivered the FET in a range of 3-16 GBq. The synthesis typically yielded 41% (21 experiments) of FET (d.c.) without an HPLC purification step. The radiochemical purity ranged between 97% and 100%. Conclusion: We present a radiosynthesis of FET where the usually used HPLC purification procedure has been substituted by a purification step based on standard cartridges. This method is useful for automatic modules without an expensive HPLC purification unit and for the routine production of FET.

  2. Microfluidic cartridges for automated, point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, Suzanne

    2016-11-01

    Full Text Available Disposable, low-cost microfluidic cartridges for automated blood cell counting applications are presented in this article. The need for point-of-care medical diagnostic tools is evident, particularly in low-resource and rural settings, and a full...

  3. Combustible Cartridge Cases: Current Status and Future Prospects

    Science.gov (United States)

    1992-08-01

    and presents new models of combustible cartridge case burning . Following a summary of experimental data, it concludes with proposals for further...UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED SAR NSN 7540-01-280-5500 Standard Form 298 (Rev 2-89) Precribed by ANSI Std Z39-19 IWFENTIONALLY LEFT BLANK...7 3.3 In-Depth Burning Model ........................................ 7 3.3.1 M odel A ................................................ 9 3.3.2

  4. Polyvinylpolypyrrolidone Supported Brønsted Acidic Catalyst for Esterification

    Directory of Open Access Journals (Sweden)

    Song Wang

    2016-01-01

    Full Text Available A polyvinylpolypyrrolidone (PVPP supported Brønsted acidic catalyst ([PVPP-BS]HSO4 was prepared by coupling SO3H-functionalized polyvinylpolypyrrolidone with H2SO4 in this work. After the characterization through FT-IR, FESEM, TG, BET, and elemental analysis, it was found that 1,4-butane sultone (BS and sulfuric acid reacted with PVPP and were immobilized on PVPP surface. The prepared [PVPP-BS]HSO4 catalyst shows high catalytic activity for a series of esterification reactions and could be separated from the reacted mixture easily. Moreover, this catalyst could be recycled and reused for six times without significant loss of catalytic performance.

  5. Bubble Jet agent release cartridge for chemical single cell stimulation.

    Science.gov (United States)

    Wangler, N; Welsche, M; Blazek, M; Blessing, M; Vervliet-Scheebaum, M; Reski, R; Müller, C; Reinecke, H; Steigert, J; Roth, G; Zengerle, R; Paust, N

    2013-02-01

    We present a new method for the distinct specific chemical stimulation of single cells and small cell clusters within their natural environment. By single-drop release of chemical agents with droplets in size of typical cell diameters (d agent release cartridge with integrated fluidic structures and integrated agent reservoirs are shown, tested, and compared in this publication. The single channel setup features a fluidic structure fabricated by anisotropic etching of silicon. To allow for simultaneous release of different agents even though maintaining the same device size, the second type comprises a double channel fluidic structure, fabricated by photolithographic patterning of TMMF. Dispensed droplet volumes are V = 15 pl and V = 10 pl for the silicon and the TMMF based setups, respectively. Utilizing the agent release cartridges, the application in biological assays was demonstrated by hormone-stimulated premature bud formation in Physcomitrella patens and the individual staining of one single L 929 cell within a confluent grown cell culture.

  6. Computer-Aided-Design of the Hydraulic System of Three-Dimensional Cartridge Valve Blocks (Selected Articles)

    Science.gov (United States)

    1991-03-21

    sectional representation of the spatial figure can be correctly determined. 6 The AutoLisp language system in the AutoCAD software provides the most...softwares are developed on the 32-bit machines and little progress has been reported for the 16-bit machines. Even the AutoCAD is a two-ard-a-half... AutoCAD software as the basis, developed the design package of 3-D cartridge valve blocks on IM PC/AT. To realize the 3-D displaying of cartridge valves

  7. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    Science.gov (United States)

    Lenselink, Charlotte H; de Bie, Roosmarie P; van Hamont, Dennis; Bakkers, Judith M J E; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2009-08-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening.

  8. Motion-Based pH Sensing Based on the Cartridge-Case-like Micromotor.

    Science.gov (United States)

    Su, Yajun; Ge, Ya; Liu, Limei; Zhang, Lina; Liu, Mei; Sun, Yunyu; Zhang, Hui; Dong, Bin

    2016-02-17

    In this paper, we report a novel cartridge-case-like micromotor. The micromotor, which is fabricated by the template synthesis method, consists of a gelatin shell with platinum nanoparticles decorating its inner surface. Intriguingly, the resulting cartridge-case-like structure exhibits a pH-dependent "open and close" feature, which originates from the pH responsiveness of the gelatin material. On the basis of the catalytic activity of the platinum nanoparticle inside the gelatin shell, the resulting cartridge-case-like structure is capable of moving autonomously in the aqueous solution containing the hydrogen peroxide fuel. More interestingly, we find out that the micromotor can be utilized as a motion-based pH sensor over the whole pH range. The moving velocity of the micromotor increases monotonically with the increase of pH of the analyte solution. Three different factors are considered to be responsible for the proportional relation between the motion speed and pH of the analyte solution: the peroxidase-like and oxidase-like catalytic behavior of the platinum nanoparticle at low and high pH, the volumetric decomposition of the hydrogen peroxide under the basic condition and the pH-dependent catalytic activity of the platinum nanoparticle caused by the swelling/deswelling behavior of the gelatin material. The current work highlights the impact of the material properties on the motion behavior of a micromotor, thus paving the way toward its application in the motion-based sensing field.

  9. Detection and Genotyping of Human Papillomavirus in Self-Obtained Cervicovaginal Samples by Using the FTA Cartridge: New Possibilities for Cervical Cancer Screening ▿

    Science.gov (United States)

    Lenselink, Charlotte H.; de Bie, Roosmarie P.; van Hamont, Dennis; Bakkers, Judith M. J. E.; Quint, Wim G. V.; Massuger, Leon F. A. G.; Bekkers, Ruud L. M.; Melchers, Willem J. G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF10-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening. PMID:19553570

  10. Rosé Wine Fining Using Polyvinylpolypyrrolidone: Colorimetry, Targeted Polyphenomics, and Molecular Dynamics Simulations.

    Science.gov (United States)

    Gil, Mélodie; Avila-Salas, Fabian; Santos, Leonardo S; Iturmendi, Nerea; Moine, Virginie; Cheynier, Véronique; Saucier, Cédric

    2017-12-06

    Polyvinylpolypyrrolidone (PVPP) is a fining agent polymer used in winemaking to adjust rosé wine color and to prevent organoleptic degradations by reducing polyphenol content. The impact of this polymer on color parameters and polyphenols of rosé wines was investigated, and the binding specificity of polyphenols toward PVPP was determined. Color measured by colorimetry decreased after treatment, thus confirming the adsorption of anthocyanins and other pigments. Phenolic composition was determined before and after fining by targeted polyphenomics (Ultra Performance Liquid Chromatography (UPLC)-Electrospray Ionization(ESI)-Mass Spectrometry (MS/MS)). MS analysis showed adsorption differences among polyphenol families. Flavonols (42%) and flavanols (64%) were the most affected. Anthocyanins were not strongly adsorbed on average (12%), but a specific adsorption of coumaroylated anthocyanins was observed (37%). Intermolecular interactions were also studied using molecular dynamics simulations. Relative adsorptions of flavanols were correlated with the calculated interaction energies. The specific affinity of coumaroylated anthocyanins toward PVPP was also well explained by the molecular modeling.

  11. Development of a method for rapid and simultaneous monitoring of particulate and dissolved radiocesium in water with nonwoven fabric cartridge filters

    International Nuclear Information System (INIS)

    Hideki Tsuji; Tetsuo Yasutaka; Yoshihiko Kondo; Yasukazu Suzuki

    2014-01-01

    A method for the rapid and simultaneous monitoring of particulate and dissolved 137 Cs concentration in water was developed. This method uses pleated polypropylene nonwoven fabric filter to collect particulate radiocesium, and nonwoven fabric impregnated with Prussian blue (PB) to absorb dissolved radiocesium. The fabric was placed into cylindrical plastic cartridges (SS-cartridge and PB-cartridge). Traditional monitoring methods, such as evaporative concentration, often require time for pre-processing. However, this method described requires much less pre-processing time before the detection. Experiments conducted with simulated river water demonstrated that almost all of the suspended solids weight was collected in the SS-cartridge, and that more than 92 % of dissolved 137 Cs was absorbed onto the two PB-cartridges by 2.5 L/min flow rate when the range of the pH was 6-8. This device was applied to monitor Abukuma River water at two locations and the results were compared with those obtained using the filtrating and evaporative concentration method. The suspended solids concentration in river water, calculated by weight gain of the SS-cartridge and by sediment weight after filtration with a 0.45-μm membrane filter, agreed well. The radioactivity of the particulate and dissolved 137 Cs also agreed well in one of the two replications of this method. In addition, the required time for pre-processing was reduced by 60 times that by filtrating and evaporative concentration method. This method can separately collect and concentrate particulate and dissolved radiocesium rapidly and simultaneously in the field. (author)

  12. Combining cationic and anionic mixed-mode sorbents in a single cartridge to extract basic and acidic pharmaceuticals simultaneously from environmental waters.

    Science.gov (United States)

    Salas, Daniela; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa Maria

    2018-01-01

    The aim of the present study is to broaden the applications of mixed-mode ion-exchange solid-phase extraction sorbents to extract both basic and acidic compounds simultaneously by combining the sorbents in a single cartridge and developing a simplified extraction procedure. Four different cartridges containing negative and positive charges in the same configuration were evaluated and compared to extract a group of basic, neutral, and acidic pharmaceuticals selected as model compounds. After a thorough optimization of the extraction conditions, the four different cartridges showed to be capable of retaining basic and acidic pharmaceuticals simultaneously through ionic interactions, allowing the introduction of a washing step with 15 mL methanol to eliminate interferences retained by hydrophobic interactions. Using the best combined cartridge, a method was developed, validated, and further applied to environmental waters to demonstrate that the method is promising for the extraction of basic and acidic compounds from very complex samples.

  13. Preparation of a New Adsorbent from Activated Carbon and Carbon Nanofiber (AC/CNF for Manufacturing Organic-Vacbpour Respirator Cartridge

    Directory of Open Access Journals (Sweden)

    Mehdi Jahangiri

    2013-01-01

    Full Text Available In this study a composite of activated carbon and carbon nanofiber (AC/CNF was prepared to improve the performance of activated carbon (AC for adsorption of volatile organic compounds (VOCs and its utilization for respirator cartridges. Activated carbon was impregnated with a nickel nitrate catalyst precursor and carbonnanofibers (CNF were deposited directly on the AC surface using catalytic chemical vapor deposition. Deposited CNFs on catalyst particles in AC micropores, were activated by CO2 to recover the surface area and micropores.Surface and textural characterizations of the prepared composites were investigated using Brunauer, Emmett andTeller’s (BET technique and electron microscopy respectively. Prepared composite adsorbent was tested forbenzene, toluene and xylene (BTX adsorption and then employed in an organic respirator cartridge in granularform. Adsorption studies were conducted by passing air samples through the adsorbents in a glass column at an adjustable flow rate. Finally, any adsorbed species not retained by the adsorbents in the column were trapped in a charcoal sorbent tube and analyzed by gas chromatography. CNFs with a very thin diameter of about 10-20 nmwere formed uniformly on the AC/CNF. The breakthrough time for cartridges prepared with CO2 activated AC/CNF was 117 minutes which are significantly longer than for those cartridges prepared with walnut shell- based activated carbon with the same weight of adsorbents. This study showed that a granular form CO2 activated AC/CNF composite could be a very effective alternate adsorbent for respirator cartridges due to its larger adsorption capacities and lower weight.

  14. Rapid and sensitive determination of phenylurea herbicides in water in the presence of their anilines by extraction with a Carbopack cartridge followed by liquid chromatography.

    Science.gov (United States)

    Di Corcia, A; Marchetti, M

    1991-03-22

    A rapid and sensitive method for determining phenylurea herbicides in environmental aqueous samples in the presence of their anilines is described. The water sample is preconcentrated by passage at a flow-rate of ca. 150 ml/min through a 250-mg graphitized carbon black (Carbopack B) cartridge. After washing with 0.6 ml of methanol, the Carbopack B trap is connected with a cartridge containing a strong cation exchanger. Organics trapped by the Carbopack cartridge are eluted by passage of 6 ml of methylene chloride-methanol (95:5, v/v). Anilines and other basic compounds are quantitatively subtracted from the solvent system while flowing through the cation-exchange cartridge. After evaporation and redissolution, the sample is subjected to reversed-phase gradient elution high-performance liquid chromatography with UV detection at 250 nm. Recoveries of phenylureas added to water at levels between 30 and 3000 ng/l were higher than 92%. The limit of detection was about 1 ng/l, for a 2-1 sample. With respect to an octadecyl (C18)-bonded silica cartridge, the Carbopack B cartridge had a far better extraction efficiency for polar phenylureas.

  15. Characteristics of a cartridge NEG (St101 Zr-Al)

    International Nuclear Information System (INIS)

    Hisamatsu, Hiromi; Shimamoto, Masayuki; Kanazawa, Ken-ichi; Ishimaru, Hajime

    1990-01-01

    The report addresses the application of a non-evaporable getter (NEG) pump to an accelerator (storage ring). Tests are performed to determine major characteristics of the non-evaporable getter pump in an effort to provide a method for its efficient use. Test results show that with an St101 cartridge NEG pump, it is possible to produce an ultrahigh vacuum in a system with a surface area of about 10 4 cm 2 through baking at 410K for two hours. Once activated at 1000K, a NEG pump recovers a pumping performance in a subsequent test run at 723K, though the pumping speed decreases by several tens of percent. The St-101 cartridge type NEG pump is at least 2 Pam 3 in pumping capacity for carbon monoxide. The pumping speed decreases with an increasing amount of occluded carbon monoxide. Upon activation, most of the occluded carbon monoxide diffuses into the pump while only little of it is released into the gas phase. Its diffusion through the surface of the NEG pump can occur even at room temperature, indicating that if a leak takes place, the pump would absorb the gas continuously. Thus, if a leak occurs during activation, the pump would occlude a large amount of gas and therefore, activation should be carried out with careful checking for a leak. (N.K.)

  16. Do insulin cartridges really provide a lower risk of potential diabetes complications than traditional vials?

    Science.gov (United States)

    Al-Sharayri, Mohammad G; Aljbori, Tariq M; Migdadi, Qusai M; Al-Omoush, Marwa B; Jaarah, Ayman R

    2014-09-01

    Recently, many publicly funded healthcare organizations suffered from an economical crisis. This forced some organizations to utilize less costly alternatives where possible. Insulin cartridges and vials are examples. Many patients are questioning the difference between the two alternatives as they contain the same active ingredient. To find out if insulin cartridges really provide a lower risk of potential diabetes complications than traditional vials. A questionnaire was used to ask two random samples of diabetic patients about the development of some diabetes complications. The first sample (n = 41) consisted of patients using cartridges; the second sample (n = 40) consisted of patients using vials. Patients were randomly selected from the endocrine clinic and the out-patient pharmacy in Al-Hussein Hospital in King Hussein Medical Center in Amman- Jordan. 44% of respondents in the first sample did not suffer from any complication; on the other hand, the percentage was only 15% of respondents in the second sample. All respondents (100%) in the first sample suffered from only 2 complications or less; however, 25% of the respondents in the second sample suffered from 3 or more complications. Nephropathy complications, were slightly higher in the first sample; 22% compared to 15% in the second sample. On the other hand, all complications reported in the second sample were higher; 30% for neuropathy, 65% for retinopathy complications and 42.5% for extremities damage compared to only 9.7%, 7.3% and 26.8% respectively in the first sample. In general, respondents who were using cartridges reported a lesser incidence of diabetes complications. Although many organizations suffered from an economical crisis, the cost-effectiveness aspect should be taken into consideration when purchasing medical alternatives. This will provide higher quality of life for patients and eventually lower hidden and future costs for the organizations.

  17. Experimental and theoretical binding affinity between polyvinylpolypyrrolidone and selected phenolic compounds from food matrices.

    Science.gov (United States)

    Durán-Lara, Esteban F; López-Cortés, Xaviera A; Castro, Ricardo I; Avila-Salas, Fabián; González-Nilo, Fernando D; Laurie, V Felipe; Santos, Leonardo S

    2015-02-01

    Polyvinylpolypyrrolidone (PVPP) is a fining agent, widely used in winemaking and brewing, whose mode of action in removing phenolic compounds has not been fully characterised. The aim of this study was to evaluate the experimental and theoretical binding affinity of PVPP towards six phenolic compounds representing different types of phenolic species. The interaction between PVPP and phenolics was evaluated in model solutions, where hydroxyl groups, hydrophobic bonding and steric hindrance were characterised. The results of the study indicated that PVPP exhibits high affinity for quercetin and catechin, moderate affinity for epicatechin, gallic acid and lower affinity for 4-methylcatechol and caffeic acid. The affinity has a direct correlation with the hydroxylation degree of each compound. The results show that the affinity of PVPP towards phenols is related with frontier orbitals. This work demonstrates a direct correlation between the experimental affinity and the interaction energy calculations obtained through computational chemistry methods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. EPA Region 8, Memo on Desktop Printer Ink Cartridges Policy & Voluntary Printer Turn-in

    Science.gov (United States)

    This memo requests EPA Region 8 users to voluntarily turn-in their desktop printers and notifies users of the Region 8 policy to not provide maintenance or ink and toner cartridges for desktop printers.

  19. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    NARCIS (Netherlands)

    Lenselink, C.H.; Bie, R.P. de; Hamont, D. van; Bakkers, J.M.J.E.; Quint, W.G.V.; Massuger, L.F.A.G.; Bekkers, R.L.M.; Melchers, W.J.G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1

  20. Inductively coupled plasma mass spectrometry study of the retention behavior of arsenic species on various solid phase extraction cartridges and its application in arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Yu Chunhai; Cai Qiantao E-mail: qtcai@cawt.sui.com.sg; Guo Zhongxian; Yang Zhaoguang; Khoo, Soo Beng

    2003-07-18

    Inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate the retention behavior of arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), arsenocholine (AsC), trimethylarsine oxide (TMAO) and tetramethylarsonium ion (TMAI) on various silica-based solid phase extraction (SPE) cartridges. A method for arsenic speciation is then developed on the basis of selective SPE separation of arsenic species and highly sensitive ICP-MS detection. Factors affecting the retention and elution of arsenic species were examined. Results showed that the retention of arsenic species depended on the chemical characteristics of arsenic species and the types of sorbent materials. Change of pH in the range of 2.0-9.0 did not show significant effects on the retention of DMA, AsB, AsC, TMAI and TMAO on an ethylbenzene sulfonic acid-based strong cation exchange (SCX-3) cartridge. pH also did not influence the retention of AsB, AsC, TMAI and TMAO on a mixed-mode (M-M) cartridge containing non-polar, strong cation exchange and strong anion exchange (SAX) functional groups. However, the retentions of As(V) and MMA on the SAX and the M-M cartridge changed with pH. As(V) and MMA were completely retained on the SAX cartridge and sequentially selectively eluted with 1.0 mol l{sup -1} acetic acid (for MMA). DMA, AsB, AsC, TMAI and TMAO were completely retained on the SCX-3 cartridge and sequentially selectively eluted with 1.0 mol l{sup -1} HNO{sub 3} (for DMA). As(V), MMA, AsB, AsC, TMAI and TMAO were completely retained on the M-M cartridge. As(III) was not retained on either cartridge and remained in solution. Arsenic species in solution and those eluted from the cartridges were subsequently determined by ICP-MS. A detection limit of 8 ng l{sup -1} arsenic in water sample was obtained. This method was successfully applied to arsenic speciation in various sources of water samples (drinking water, waste water, raw water, etc.) and US

  1. Positive detection of exfoliated colon cancer cells on linear stapler cartridges was associated with depth of tumor invasion and preoperative bowel preparation in colon cancer.

    Science.gov (United States)

    Ikehara, Kishiko; Endo, Shungo; Kumamoto, Kensuke; Hidaka, Eiji; Ishida, Fumio; Tanaka, Jun-Ichi; Kudo, Shin-Ei

    2016-08-31

    The aim of this study was to investigate exfoliated cancer cells (ECCs) on linear stapler cartridges used for anastomotic sites in colon cancer. We prospectively analyzed ECCs on linear stapler cartridges used for anastomosis in 100 colon cancer patients who underwent colectomy. Having completed the functional end-to-end anastomosis, the linear stapler cartridges were irrigated with saline, which was collected for cytological examination and cytological diagnoses were made by board-certified pathologists based on Papanicolaou staining. The detection rate of ECCs on the linear stapler cartridges was 20 %. Positive detection of ECCs was significantly associated with depth of tumor invasion (p = 0.012) and preoperative bowel preparation (p = 0.003). There were no marked differences between ECC-positive and ECC-negative groups in terms of the operation methods, tumor location, histopathological classification, and surgical margins. Since ECCs were identified on the cartridge of the linear stapler used for anastomosis, preoperative mechanical bowel preparation using polyethylene glycol solution and cleansing at anastomotic sites using tumoricidal agents before anastomosis may be necessary to decrease ECCs in advanced colon cancer.

  2. Environmental impacts and resource losses of incinerating misplaced household special wastes (WEEE, batteries, ink cartridges and cables)

    DEFF Research Database (Denmark)

    Bigum, Marianne Kristine Kjærgaard; Damgaard, Anders; Scheutz, Charlotte

    2017-01-01

    The contribution of misplaced special waste (sWEEE, lamps, CRT, batteries, ink cartridges and cables) to environmental impacts from incineration of residual household waste was quantified through life cycle assessment (LCA)-modelling. Misplaced special waste was quantified to constitute less than 1...... and batteries. However as shown by sensitivity analysis, lack of good data on the transfer of rare and hazardous metals to the flue gas in the incineration process should receive further investigation before the environmental impacts from misplaced incinerated special waste can fully be concluded upon. Although...... special waste (sWEEE, lamps, CRT, batteries, ink cartridges, and cables)....

  3. Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe

    Directory of Open Access Journals (Sweden)

    T D Yogesh Kumar

    2015-01-01

    Full Text Available Aim: The present study evaluated and compared the pain perception, behavioral response, physiological parameters, and the role of topical anesthetic administration during local anesthetic administration with cartridge syringe and computer controlled local anesthetic delivery system (CCLAD. Design: A randomized controlled crossover study was carried out with 120 children aged 7-11 years. They were randomly divided into Group A: Receiving injection with CCLAD during first visit; Group B: Receiving injection with cartridge syringe during first visit. They were further subdivided into three subgroups based on the topical application used: (a 20% benzocaine; (b pressure with cotton applicator; (c no topical application. Pulse rate and blood pressure were recorded before and during injection procedure. Objective evaluation of disruptive behavior and subjective evaluation of pain were done using face legs activity cry consolability scale and modified facial image scale, respectively. The washout period between the two visits was 1-week. Results: Injections with CCLAD produced significantly lesser pain response, disruptive behavior (P < 0.001, and pulse rate (P < 0.05 when compared to cartridge syringe injections. Application of benzocaine produced lesser pain response and disruptive behavior when compared to the other two subgroups, although the result was not significant. Conclusion: Usage of techniques which enhance behavioral response in children like injections with CCLAD can be considered as a possible step toward achieving a pain-free pediatric dental practice.

  4. Influence Factors Regarding the Effectiveness of Automated Ballistic Comparison on 0.38 Special Caliber Bullets and Cartridge Cases.

    Science.gov (United States)

    Dos Santos, Lehi Sudy; Vieira Muterlle, Palloma

    2018-03-01

    Factors influencing effectiveness of automated comparisons, test-fired bullets, and cartridge cases from 0.38 Special revolvers were logged into the Evofinder ® Ballistic ID System. Tests were performed as follows: First test correlated test-fires of the same type, second test compared different types of ammunition components, third test replicated the second test in a larger database, and fourth test replicated the third test with students having no previous firearm identification experience. System effectiveness with projectiles in the first test was 0.89. With cartridge cases, effectiveness was 0.79 with combined results, but analysis of separate results by breech face and firing pin revealed low effectiveness by breech face (0.40). In the second, third, and fourth tests, effectiveness with projectiles were 0.61, 0.51, and 0.44. In addition, these tests had effectiveness with cartridge cases equivalent to 0.55, 0.43, and 0.44. Results are useful to establish routine protocols, system improvements, or comparative assessment of other electronic systems. © 2018 American Academy of Forensic Sciences.

  5. A patterned abrasion caused by the impact of a cartridge case may simulate an atypical muzzle imprint mark.

    Science.gov (United States)

    Kramer, Lena; Nadjem, Hadi; Glardon, Matthieu; Kneubuehl, Beat P; Pollak, Stefan; Große Perdekamp, Markus; Pircher, Rebecca

    2016-05-01

    In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.

  6. Development and Preliminary Assessment of Hemoperfusion Cartridge with Tannic Acid for Toxic Proteins' Precipitation: An In Vitro Model

    Directory of Open Access Journals (Sweden)

    Valquíria Miwa Hanai Yoshida

    2016-09-01

    Full Text Available Charcoal hemoperfusion (CHP is one of the extracorporeal removal techniques that are used to remove toxins from the body. CHP generally is considered the preferred method for extracorporeal extraction of several toxins—toxins that are adsorbed by activated charcoal. Assessments of the tannic acid's protective effects on ophidian poisoning are associated with the toxic proteins' precipitation by tannic acid. The challenge in treating a snakebite lies in removing the injected poison with minimal damage to blood constituent proteins. An alternative is CHP, and this investigation proposed to develop a column for hemoperfuser cartridge, combining charcoal granules trapped between layers of polymeric material conjugated to tannic acid, using an in vitro model scaled to the Wistar rat, which can be tested in an animal model. The cartridge was evaluated using the 22 full factorial design, in duplicate, as a method to study the effects of granulated-charcoal size and tannic acid concentration on the hematologic profile (platelet and leukocyte counts and biochemical profile (total serum protein and albumin dosages of sheep blood. The results demonstrate that charcoal in hemoperfuser cartridge: (1 decreases the serum in sheep blood volume, as consequence, (2 increases the serum proteins' concentration, and (iii exerts slight influence on albumin. The inclusion of tannic acid in hemoperfuser column precipitates some of serum proteins and albumin, decreasing their concentrations in the plasma serum. In conclusion, based on these effects we can suggest the use of 0.02 g tannic acid concentration and 8–20 mesh granulated charcoal in hemoperfuser cartridge for precipitating toxic proteins from snake venoms.

  7. Safety limits of half-mask cartridge respirators for organic solvent vapors

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Recent studies of the effective service life (safety limits) for typical half-mask cartridge respirators have shown these devices to be unsuitable for certain organic vapors, e.g., methanol, methylamine, vinyl chloride, and dichloromethane, because the effective service life is too short. For these vapors other forms of protection such as air-supplied respirators are recommended. The experimentally determined service life for many vapors is shorter--sometimes significantly shorter--than predicted by adsorption theory

  8. RPA using a multiplexed cartridge for low cost point of care diagnostics in the field.

    Science.gov (United States)

    Ereku, Luck Tosan; Mackay, Ruth E; Craw, Pascal; Naveenathayalan, Angel; Stead, Thomas; Branavan, Manorharanehru; Balachandran, Wamadeva

    2018-04-15

    A point of care device utilising Lab-on-a-Chip technologies that is applicable for biological pathogens was designed, fabricated and tested showing sample in to answer out capabilities. The purpose of the design was to develop a cartridge with the capability to perform nucleic acid extraction and purification from a sample using a chitosan membrane at an acidic pH. Waste was stored within the cartridge with the use of sodium polyacrylate to solidify or gelate the sample in a single chamber. Nucleic acid elution was conducted using the RPA amplification reagents (alkaline pH). Passive valves were used to regulate the fluid flow and a multiplexer was designed to distribute the fluid into six microchambers for amplification reactions. Cartridges were produced using soft lithography of silicone from 3D printed moulds, bonded to glass substrates. The isothermal technique, RPA is employed for amplification. This paper shows the results from two separate experiments: the first using the RPA control nucleic acid, the second showing successful amplification from Chlamydia Trachomatis. Endpoint analysis conducted for the RPA analysis was gel electrophoresis that showed 143 base pair DNA was amplified successfully for positive samples whilst negative samples did not show amplification. End point analysis for Chlamydia Trachomatis samples was fluorescence detection that showed successful detection of 1 copy/μL and 10 copies/μL spiked in a MES buffer. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  9. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  10. Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps

    Directory of Open Access Journals (Sweden)

    Sascha Geidel

    2016-09-01

    Full Text Available While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.

  11. 3D-Printed Paper Spray Ionization Cartridge with Integrated Desolvation Feature and Ion Optics

    NARCIS (Netherlands)

    Salentijn, G Ij; Oleschuk, R D; Verpoorte, E

    2017-01-01

    In this work we present the application of 3D-printing for the miniaturization and functionalization of an ion source for (portable) mass spectrometry (MS). Two versions of a 3D-printed cartridge for paper spray ionization (PSI) are demonstrated, assessed, and compared. We first focus on the use of

  12. Hydrogen Car Cartridges: A New Strategy for Hydrogen Storage, Delivering and Refueling

    Energy Technology Data Exchange (ETDEWEB)

    Prosini, Pier Paolo

    2007-07-01

    The purpose of the project is to introduce a sustainable model in the automotive field, guarantying the Kyoto agreements. The aim of the project is to develop an innovative hydrogen tank able to power an hydrogen fuel cell car with the same performance of liquid fuelled cars. Most of the system performance are expected to satisfy the Department of Energy (DOE) goals for 2015. The hydrogen releasing system is based on solid NaBH4 which is hydrolyzed with water or steam to obtain hydrogen. Sodium borate is obtained as by-product and it has to be recycled. Pure and humidified hydrogen, ready to be utilized in a fuel cell, is obtained by a simple and sure way. Hydrogen is produced only when it is requested and therefore there is never pressurized hydrogen or hydrogen overproduction The system works at atmospheric pressure avoiding the problems related to handling and storing pressurized gas. The car fuelling could be performed in area like the present service stations. The used cartridges can be removed and substituted by new cartridges. Contemporarily a water tank should be refilled. To improve the total energetic yield it was also proposed a NaBH4 regeneration process directly starting from the products of hydrolysis. (auth)

  13. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Science.gov (United States)

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Rapid monitoring particulate radiocesium with nonwoven fabric cartridge filter and application to field monitoring

    International Nuclear Information System (INIS)

    Tsuji, Hideki; Yasutaka, Tetsuo; Kondo, Yoshihiko; Kawashima, Shoji

    2013-01-01

    A method for rapid monitoring particulate radiocesium using a nonwoven fabric cartridge filter was developed, which needs no further preprocessing before served to a detector. By a performance test, more than 98% of suspended solid (SS) was collected. This method showed the same radioactivity measurement accuracy as filtration by membrane filter and more rapid extraction capability of SS. (author)

  15. Time since discharge of 9mm cartridges by headspace analysis, part 1: Comprehensive optimisation and validation of a headspace sorptive extraction (HSSE) method.

    Science.gov (United States)

    Gallidabino, M; Romolo, F S; Weyermann, C

    2017-03-01

    Estimating the time since discharge of spent cartridges can be a valuable tool in the forensic investigation of firearm-related crimes. To reach this aim, it was previously proposed that the decrease of volatile organic compounds released during discharge is monitored over time using non-destructive headspace extraction techniques. While promising results were obtained for large-calibre cartridges (e.g., shotgun shells), handgun calibres yielded unsatisfying results. In addition to the natural complexity of the specimen itself, these can also be attributed to some selective choices in the methods development. Thus, the present series of paper aimed to more systematically evaluate the potential of headspace analysis to estimate the time since discharge of cartridges through the use of more comprehensive analytical and interpretative techniques. Specifically, in this first part, a method based on headspace sorptive extraction (HSSE) was comprehensively optimised and validated, as the latter recently proved to be a more efficient alternative than previous approaches. For this purpose, 29 volatile organic compounds were preliminary selected on the basis of previous works. A multivariate statistical approach based on design of experiments (DOE) was used to optimise variables potentially involved in interaction effects. Introduction of deuterated analogues in sampling vials was also investigated as strategy to account for analytical variations. Analysis was carried out by selected ion mode, gas chromatography coupled to mass spectrometry (GC-MS). Results showed good chromatographic resolution as well as detection limits and peak area repeatability. Application to 9mm spent cartridges confirmed that the use of co-extracted internal standards allowed for improved reproducibility of the measured signals. The validated method will be applied in the second part of this work to estimate the time since discharge of 9mm spent cartridges using multivariate models. Copyright

  16. Comparison of a gel column blood typing method and a point-of-care cartridge for dog erythrocyte antigen 1.1.

    Science.gov (United States)

    Blois, Shauna L; Richardson, Danielle M; Abrams-Ogg, Anthony C G

    2013-01-01

    Blood typing for the presence of Dog Erythrocyte Antigen (DEA) 1.1 is recommended in all donor and recipient dogs prior to transfusion of blood products. The objective of this study was to determine if a point-of-care DEA 1.1 blood typing cartridge could be used in place of the gel column typing method. Detection of DEA 1.1 was performed using a laboratory-based gel column method and a point-of-care cartridge. A convenience sample of 30 healthy blood donors, 13 dogs with immune-mediated hemolytic anemia (IMHA) (3 of which had concurrent immune-mediated thrombocytopenia [IMT]), and 44 dogs with other diseases was included in the study. Agreement was observed between the tests for normal dogs and dogs with nonimmune-mediated disease in 74/74 cases. Two dogs in the IMHA group had indeterminate gel column blood typing results; 1 dog in this group had a negative gel column test result but a positive cartridge test result. There was good agreement between the 2 methods for normal dogs and dogs with nonimmune-mediated disease. Blood typing methods in dogs with IMHA should be further investigated. © Veterinary Emergency and Critical Care Society 2013.

  17. Engineering evaluation of solids/liquids separation processes applicable to sludge treatment project

    International Nuclear Information System (INIS)

    Duncan, J.B.

    1998-01-01

    This engineering study looks at the solids/liquids separation unit operations after the acid dissolution of the K Basin sludge treatment. Unit operations considered were centrifugation, filtration (cartridge, cross flow, and high shear filtration) and gravity settling. The recommended unit operations for the solids/liquids separations are based upon the efficiency, complexity, and off-the-shelf availability and adaptability. The unit operations recommended were a Robatel DPC 900 centrifuge followed by a nuclearized 31WM cartridge filter. The Robatel DPC 900 has been successfully employed in the nuclear industry on a world wide scale. The 31WM cartridge filter has been employed for filtration campaigns in both the government and civilian nuclear arenas

  18. Unsuitability of using the DNPH-coated solid sorbent cartridge for determination of airborne unsaturated carbonyls

    Science.gov (United States)

    Ho, Steven Sai Hang; Ho, K. F.; Liu, W. D.; Lee, S. C.; Dai, W. T.; Cao, J. J.; Ip, H. S. S.

    2011-01-01

    Measurements of aldehydes and ketones are typically conducted by derivatization using sorbent cartridges coated with 2,4-dinitrophenylhydrazine (DNPH). The collected samples are eluted with acetonitrile and analyzed by high-pressure liquid chromatography coupled with an ultra-violet detector (HPLC/UV). This paper intends to examine artifacts about its suitability in identification of unsaturated carbonyls. Kinetic tests for acrolein, crotonaldehyde, methacrolein and methyl vinyl ketone (MVK) showed formations of carbonyl-DNP-hydrazone during sampling, which could further react with DNPH, resulting in undesired UV absorption products [e.g., carbonyl-DNP-hydrazone-DNPH (dimer) and 2(carbonyl-DNP-hydrazone)-DNPH (trimer)]. The dimerization and trimerization occurred for acrolein and MVK whereas only dimerization for crotonaldehyde and methacrolein. The polymerization products undoubtedly affect the integrity of the chromatogram, leading to misidentification and inaccurate quantification. Whether precautions taken during sampling and/or sample treatment could avoid or minimize this artifact has not been thoughtfully investigated. More often, such artifacts are usually overlooked by scientists when the data are reported.

  19. The security management of spent filter cartridge in Qinshan phase 3 (heavy water reactor) nuclear power plant

    International Nuclear Information System (INIS)

    Xue Dahai

    2005-01-01

    Qinshan phase 3 nuclear power plant is the first CANDU plant that China fetched in from Canada, and both two units operate under well condition up to now. The radioactive wastes produced during the unit operation mainly include technical waste, spent resin, and spent filter cartridge. The spent filter cartridge is one important part both in the volume and radioactivity of the radioactive waste, and it is the important content of radioactive waste management. Different from PWR, part of high radioactive spent filter in CANDU unit comes from heavy water system such as moderator system. It has to be dried through blowing before replaced from the system. But this working procedure result the filtrate dreg become flexible, and it can bring on the risk of internal or external exposure. It is very important to pay high attention to control the contamination spread during spent filter inside transfer. (authors)

  20. Separation of V(V)-4-(2-pyridylazo)resorcinolato complex from a large excess reagent using an ODS cartridge for high-performance liquid chromatography.

    Science.gov (United States)

    Takahashi, Toru; Kaneko, Emiko; Yotsuyanagi, Takao

    2006-12-01

    A selective off-line preconcentration technique for the V(V) complex with 4-(2-pyridylazo)resorcinol has been developed and successfully applied to the determination of V(V) in an air-borne sample. The target complex was separated from excess reagent using an ODS cartridge and water as the eluent. The complex was then concentrated on another ODS cartridge using tetrabutylammonium bromide and eluted with methanol; the eluate was applied to a one-drop concentration/HPLC. A detection limit as low as (6.05 +/- 0.82)x 10(-11) M (5 ppt) was achieved.

  1. Characterization of filters cartridges from the water polishing system of IEA-R1 reactor: radiometric methods

    International Nuclear Information System (INIS)

    Tessaro, Ana Paula G.; Vicente, Roberto

    2015-01-01

    The acceptance of radioactive waste in a repository depends primarily on knowledge of the radioisotopic inventory of the material, according to regulations established by regulatory agencies. The primary characterization is also a fundamental action to determine further steps in the management of the radioactive wastes. The aim of this work is to report the development of non-destructive methods for primary characterization of filters cartridges discarded as radioactive waste. The filters cartridges are used in the water polishing system of the IEA-R1 reactor retaining the particles in suspension in the reactor cooling water. The IEA-R1 is a pool type reactor with a thermal power of 5 MW, moderated and cooled with light water. It is located in the Energy and Nuclear Research Institute (IPEN-CNEN), in São Paulo, Brazil. The cartridge filters become radioactive waste when they are saturated and do not meet the required flow for the proper operation of the water polishing system. The activities of gamma emitters present in the filters are determined using gamma spectrometry, dose rate measurements and the Point Kernel Method to correlate results from both measurements. For the primary characterization, one alternative method is the radiochemical analysis of slices taken from each filter, what presents the disadvantage of higher exposures personnel and contamination risks. Another alternative method is the calibration of the measurement geometry of a gamma spectrometer, which requires the production of a standard filter. Both methods are necessary but can not be used in operational routine of radioactive waste management owing to cost and complexity. The method described can be used to determine routinely the radioactive inventory of these filters and other radioactive wastes, avoiding the necessity of destructive radiochemical analysis, or the necessity of calibrating the geometry of measurement. (author)

  2. A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system.

    Science.gov (United States)

    Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan

    2015-10-01

    An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.

  3. Double versus single cartridge of 4% articaine infiltration into the retro-molar area for lower third molar surgery.

    Science.gov (United States)

    Sawang, Kamonpun; Chaiyasamut, Teeranut; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Bhattarai, Bishwa Prakash; Wongsirichat, Natthamet

    2017-06-01

    There are no studies regarding 4% articaine infiltration injection into the retro-molar area for an impacted lower third molar (LITM) surgery. This study aimed to evaluate the efficacy of infiltration using 1.7 ml (single cartridge: SC) of 4% articaine versus 3.4 ml (double cartridges: DC) of 4% articaine with 1:100,000 epinephrine in LITM surgery. This study involved 30 healthy patients with symmetrical LITM. The patients were assigned to receive either a DC or SC of 4% articaine with 1:100,000 epinephrine as a local anesthetic for each operation. Onset, duration, profoundness, need for additional anesthetic administration, total volume of anesthetic used, vitality of the tooth, and pain score during operation were recorded. The DC of 4 % articaine had a significantly higher success rate (83.3%) than did the SC (53.3%; P molar region can be an alternative anesthetic for LITM surgery.

  4. Fast and Easy Drying Method for the Preparation of Activated [{sup 18}F]Fluoride Using Polymer Cartridge

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jai Woong [Inha University, Inchon (Korea, Republic of); Lee, Byoung Se; Chi, Dae Yoon [FutureChem Co., Ltd., Seoul (Korea, Republic of); Lee, Sang Ju [Sogang University, Seoul (Korea, Republic of); Oh, Seung Jun [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2011-01-15

    An efficient nucleophilic [{sup 18}F]fluorination has been studied to reduce byproducts and preparation time. Instead of conventional aqueous solution of K{sub 2}CO{sub 3}-K{sub 222}, several organic solution containing inert organic salts were used to release [{sup 18}F]fluoride ion and anion bases captured in the polymer cartridge, concluding that methanol solution is the best choice. Comparing to azeotropic drying process, one min was sufficient to remove methanol completely, resulting in about 10% radioactivity saving by reducing drying time. The polymer cartridge, Chromafix (PS-HCO{sub 3}) was pretreated with several anion bases to displace pre-loaded bicarbonate base. Phosphate bases showed better results than carbonate bases in terms of lower basicity. tert-Butanol solvent used as a reaction media played another critical role in nucleophilic [{sup 18}F]fluorination by suppressing eliminated side product. Consequent [{sup 18}F]fluorination under the present condition afforded fast preparation of reaction solution and high radiochemical yields (98% radio-TLC, 84% RCY) with 94% of precursor remained.

  5. Permanent disposal of radioactive particulate waste in cartridge containing ferromagnetic material

    International Nuclear Information System (INIS)

    Troy, M.

    1986-01-01

    This patent describes a cartridge for permanent disposal of solid radioactive particulate waste, comprising; a liquid impervious casing having an upper end cover, a lower end cover and a side wall extending between the covers, the casing enclosing a waste storage region; ferromagnetic fibrous material defining a waste retaining matrix and filling a major portion of the waste storage region; means defining an inlet conduit extending through the upper end cover and axially of the casing through the waste storage region, and opening into the waste storage region in the vicinity of the lower and end cover; and means defining first and second outlet conduits extending through the upper end cover and opening into the waste storage region in the vicinity of the upper end cover

  6. On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods

    International Nuclear Information System (INIS)

    Li, Jianjun; Liu, Yun; Liu, Qianping; Hui, Junfeng; Liu, Yangzi

    2017-01-01

    A novel method for determination of sodium cyclamate in foods was developed. In this method, a syringe was loaded with the homogeneous mixture of the sample, KMnO 4 powder and silica dispersant and used as a matrix solid phase dispersion (MSPD) reactor. As the reactor was infiltrated with small amounts of concentrated HCl, cyclamate was converted to 2-chlorocyclohexanone quickly and effectively within 5 min and determined by HPLC on a reversed-phase column using UV detection at a wavelength of 310 nm. Comparing with the traditional derivatisation in solution, the better clean-up was provided using on-cartridge derivatisation of MSPD, and much time, labor, and expense were saved. The results showed good linearity (r 2  = 0.9998) over the concentration range of 1–500 mg/L. The limit of detection (LOD) and limits of quantification (LOQ) of the cyclamate were 0.3 mg/L and 1 mg/L respectively. The recoveries ranged from 91.6% to 101.3% with the relative standard deviations (RSDs) in the range of 2.5%–4.3%. - Highlights: • A novel method was developed for the determination of cyclamate in foods. • On cartridge derivatisation, using matrix solid phase dispersion, was developed. • A new derivatisation reaction for cyclamate conversion to 2-chlorocyclohexanone was developed. • The method was rapid, simple, inexpensive, effective.

  7. Comparison between a commercial solid-phase extraction cartridge and a home-made silver containing charcoal column: purification of Mo-99 from I-131 and Te-121

    International Nuclear Information System (INIS)

    Dias, Carla Roberta; Teodoro, Rodrigo; Osso Junior, Joao

    2011-01-01

    Among the radioisotopes used for medical application in Nuclear Medicine, 99m Tc, readily available from the elution of 99 Mo/ 99m Tc generators, is the most used, responsible for more than eighty percent of the total applications. These generators use the 99 Mo radioisotope that is produced in nuclear reactors and IPEN imports all the 99 Mo used in Brazil, mainly from Canada (Nordion). Due to the increasing needs of the Nuclear Medicine in Brazil and the world shortage of 99 Mo observed since 2008, IPEN decided to construct a new research reactor named Brazilian Multipurpose Reactor (BMR) as well as to develop the production of 99 Mo through the route of 235 U fission using a CINTICHEM modified separation process. The 99 Mo obtained from this process contains some contaminants and need to be purified. The aim of this work is to compare the preliminary results of the purification step of the solution containing 99 Mo and the contaminants, 131 I and 121 Te in the silver containing charcoal column and a solid-phase extraction cartridge. The purification process of 99 Mo coming from fission LEU foils was performed by adsorption chromatography using a home-made activated charcoal containing silver column (AC-Ag) and a commercial solid-phase extraction cartridge (OnGuard II Ag). High yields of 99 Mo elution and high retention of 131 I were achieved in the AC-Ag column and silver cartridge but 121 Te was more retained in the cartridge than in the AC-Ag column. (author)

  8. Disposable cartridge extraction of retinol and alpha-tocopherol from fatty samples.

    Science.gov (United States)

    Bourgeois, C F; Ciba, N

    1988-01-01

    A new approach is proposed for liquid/solid extraction of retinol and alpha-tocopherol from samples, using a disposable kieselguhr cartridge. The substitution of the mixture methanol-ethanol-n-butanol (4 + 3 + 1) for methanol in the alkaline hydrolysis solution makes it now possible to process fatty samples. Methanol is necessary to solubilize the antioxidant ascorbic acid, and a linear chain alcohol such as n-butanol is necessary to reduce the size of soap micelles so that they can penetrate into the kieselguhr pores. In comparisons of the proposed method with conventional methods on mineral premixes and fatty feedstuffs, recovery and accuracy are at least as good by the proposed method. Advantages are increased rate of determinations and the ability to hydrolyze and extract retinol and alpha-tocopherol together from the same sample.

  9. Characterization of filter cartridges from the IEA-R1 reactor by radiochemical method

    International Nuclear Information System (INIS)

    Geraldo, Bianca; Vicente, Roberto; Ferreira, Robson J.; Goes, Marcos M.; Marumo, Julio T.

    2015-01-01

    The filter cartridges used in water purification system of research nuclear reactor IEA-R1 are considered radioactive wastes after their useful life. The characterization of these wastes is one of the stages of management, which aims to identify and quantify the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Establish a radiochemical analysis methodology for this type of waste is a difficult job, not only by the application of these techniques, but also by the amount of radionuclides that should be analyzed. In the waste produced in a nuclear reactor, the most important radionuclides are fission products, activation products and transuranic elements. Since these radionuclides emit gamma radiation not measurable in its decay process and consequently are difficult to measure, their concentrations can be estimated by indirect methods such as scale factors. This method is used to evaluate the DTM concentration, which is represented by alpha and beta nuclides using the correlation between them and the radionuclide key, a gamma emitter. The objective of this work is to describe a radiochemical analysis methodology for gamma emitter nuclides, present in the filter cartridges, evaluating the activity and concentrations by destructive assays. At the same time, two studies have been performed by non-destructive assays, the first one based on dose rates and the point kernel method to correlate the results and the second one based on calibration efficiency with Monte Carlo method. These studies belong to the radioactive waste characterization program that has been conducted at the Waste Management Laboratory of Nuclear and Energy Research Institute, IPEN-CNEN/SP. (author)

  10. Characterization of filter cartridges from the IEA-R1 reactor by radiochemical method

    Energy Technology Data Exchange (ETDEWEB)

    Geraldo, Bianca; Vicente, Roberto; Ferreira, Robson J.; Goes, Marcos M.; Marumo, Julio T., E-mail: bgeraldo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The filter cartridges used in water purification system of research nuclear reactor IEA-R1 are considered radioactive wastes after their useful life. The characterization of these wastes is one of the stages of management, which aims to identify and quantify the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Establish a radiochemical analysis methodology for this type of waste is a difficult job, not only by the application of these techniques, but also by the amount of radionuclides that should be analyzed. In the waste produced in a nuclear reactor, the most important radionuclides are fission products, activation products and transuranic elements. Since these radionuclides emit gamma radiation not measurable in its decay process and consequently are difficult to measure, their concentrations can be estimated by indirect methods such as scale factors. This method is used to evaluate the DTM concentration, which is represented by alpha and beta nuclides using the correlation between them and the radionuclide key, a gamma emitter. The objective of this work is to describe a radiochemical analysis methodology for gamma emitter nuclides, present in the filter cartridges, evaluating the activity and concentrations by destructive assays. At the same time, two studies have been performed by non-destructive assays, the first one based on dose rates and the point kernel method to correlate the results and the second one based on calibration efficiency with Monte Carlo method. These studies belong to the radioactive waste characterization program that has been conducted at the Waste Management Laboratory of Nuclear and Energy Research Institute, IPEN-CNEN/SP. (author)

  11. Ways of increasing of efficiency of the use of chemical gazogene cartridges at the mining of facing raw material

    OpenAIRE

    Кальчук, Сергій Володимирович; Лукащук, Олександр Вікторович

    2016-01-01

    The analysis and theoretical generalizations of influencing of the known methods of separation to the stone on the array of breeds is executed. Certain backlogs of increase of the OIR use of chemical gazogene cartridges. Offered ways of determination of optimum parameters of most effective their applications on the deposits of facing stone.

  12. Type-specific detection of high-risk human papillomavirus (HPV) in self-sampled cervicovaginal cells applied to FTA elute cartridge.

    Science.gov (United States)

    Gustavsson, Inger; Sanner, Karin; Lindell, Monica; Strand, Anders; Olovsson, Matts; Wikström, Ingrid; Wilander, Erik; Gyllensten, Ulf

    2011-08-01

    Most procedures for self-sampling of cervical cells are based on liquid-based media for transportation and storage. An alternative is to use a solid support, such as dry filter paper media. To evaluate if self-sampling of cervicovaginal fluid using a cytobrush (Viba-brush; Rovers Medical Devices B.V., Oss, The Netherlands) and a solid support such as the Whatman Indicating FTA Elute cartridge (GE Healthcare, United Kingdom) can be used for reliable typing of human papillomavirus (HPV), as compared to cervical samples obtained by a physician using a cytobrush and the indicating FTA Elute Micro card and biopsy analysis. A total of 50 women with a previous high-risk (HR) HPV positive test were invited to perform self-sampling using the Viba-brush and the FTA cartridge and thereafter a physician obtained a cervical sample using the cytobrush and a FTA card, together with a cervical biopsy for histology and HPV typing. Detection of HR-HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58 and 59 was performed using three multiplex real-time polymerase chain reaction (PCR) assays. All samples contained sufficient amounts of genomic DNA and the self-samples yielded on average 3.5 times more DNA than those obtained by the physician. All women that were positive for HR-HPV in the biopsy sample also typed positive both by self-sampling and physician-obtained sampling. For women with a histological diagnosis of cervical intraepithelial neoplasia grades 2-3 (CIN 2-3) all three HPV samples showed 100% concordance. A higher number of women were HPV positive by self-sampling than by physician-obtained sampling or by biopsy analysis. The Viba-brush and the FTA cartridge are suitable for self-sampling of vaginal cells and subsequent HR-HPV typing. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jianjun, E-mail: bootan12@126.com [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Northwest University, Xi' an 710069 (China); National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China); Liu, Yun [College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi' an 710062 (China); Liu, Qianping [National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China); Hui, Junfeng [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Northwest University, Xi' an 710069 (China); Liu, Yangzi [National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China)

    2017-06-15

    A novel method for determination of sodium cyclamate in foods was developed. In this method, a syringe was loaded with the homogeneous mixture of the sample, KMnO{sub 4} powder and silica dispersant and used as a matrix solid phase dispersion (MSPD) reactor. As the reactor was infiltrated with small amounts of concentrated HCl, cyclamate was converted to 2-chlorocyclohexanone quickly and effectively within 5 min and determined by HPLC on a reversed-phase column using UV detection at a wavelength of 310 nm. Comparing with the traditional derivatisation in solution, the better clean-up was provided using on-cartridge derivatisation of MSPD, and much time, labor, and expense were saved. The results showed good linearity (r{sup 2} = 0.9998) over the concentration range of 1–500 mg/L. The limit of detection (LOD) and limits of quantification (LOQ) of the cyclamate were 0.3 mg/L and 1 mg/L respectively. The recoveries ranged from 91.6% to 101.3% with the relative standard deviations (RSDs) in the range of 2.5%–4.3%. - Highlights: • A novel method was developed for the determination of cyclamate in foods. • On cartridge derivatisation, using matrix solid phase dispersion, was developed. • A new derivatisation reaction for cyclamate conversion to 2-chlorocyclohexanone was developed. • The method was rapid, simple, inexpensive, effective.

  14. Domestic Preparedness: Phase 2 Sarin Vapor Challenge and Corn Oil Protection Factor (PF) Testing of Commercial Powered Air Purifying Respirator (PAPR) Systems and Cartridges

    National Research Council Canada - National Science Library

    Campbell, Lee E; Lins, Ray; Pappas, Alex G

    2002-01-01

    .... Results indicate that cartridges provide complete penetration resistance against 200 mg/m3 GB challenge concentrations for 60 minutes, but that unacceptably high levels of GB vapor and corn oil...

  15. New polymer for removal of wine phenolics: Poly(N-(3-(N-isobutyrylisobutyramido)-3-oxopropyl)acrylamide) (P-NIOA).

    Science.gov (United States)

    Castro, Ricardo I; Forero-Doria, Oscar; Guzmán, Luis; Laurie, V Felipe; Valdés, Oscar; Ávila-Salas, Fabián; López-Cortés, Xaviera; Santos, Leonardo S

    2016-12-15

    The phenolic compounds of wine contribute to color and astringency, also are responsible for the oxidation state and bitterness. Due the importance of these molecules, different techniques have been used to modulate their concentration such as natural or synthetic polymeric agents. Among the polymeric agents, PVPP is one of the most used, but lacks of selectivity and has a limited pH range. Therefore, the aim of this study was the synthesis of a new polymer, poly(N-(3-(N-isobutyrylisobutyramido)-3-oxopropyl)acrylamide) (P-NIOA), for removal of phenolic compounds, as a potential agent for the fining of wine. The new polymer affinity was studied using HPLC-DAD for different polyphenols using PVPP as a control. The results showed that the new polymer has a similar removal as PVPP, but with lower affinity to resveratrol. The interactions established between polymers and polyphenols were studied using computational chemistry methods demonstrating a direct correlation with the experimental affinity data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge

    OpenAIRE

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Fr?d?ric; Petignat, Patrick

    2015-01-01

    Background Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. Methods A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed f...

  17. Thermal enhancement cartridge heater modified (TECH Mod) tritium hydride bed development, Part 1 - Design and fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.E.; Estochen, E.G. [Savannah River National Laboratory, Aiken, SC (United States)

    2015-03-15

    The Savannah River Site (SRS) tritium facilities have used first generation (Gen1) LaNi{sub 4.25}Al{sub 0.75} (LANA0.75) metal hydride storage beds for tritium absorption, storage, and desorption. The Gen1 design utilizes hot and cold nitrogen supplies to thermally cycle these beds. Second and third generation (Gen2 and Gen3) storage bed designs include heat conducting foam and divider plates to spatially fix the hydride within the bed. For thermal cycling, the Gen2 and Gen3 beds utilize internal electric heaters and glovebox atmosphere flow over the bed inside the bed external jacket for cooling. The currently installed Gen1 beds require replacement due to tritium aging effects on the LANA0.75 material, and cannot be replaced with Gen2 or Gen3 beds due to different designs of these beds. At the end of service life, Gen1 bed desorption efficiencies are limited by the upper temperature of hot nitrogen supply. To increase end-of-life desorption efficiency, the Gen1 bed design was modified, and a Thermal Enhancement Cartridge Heater Modified (TECH Mod) bed was developed. Internal electric cartridge heaters in the new design to improve end-of-life desorption, and also permit in-bed tritium accountability (IBA) calibration measurements to be made without the use of process tritium. Additional enhancements implemented into the TECH Mod design are also discussed. (authors)

  18. Determining the effect of cartridge case coatings on GSR using post-fire priming cup residue.

    Science.gov (United States)

    Terry, Molly; Fookes, Barry; Bridge, Candice M

    2017-07-01

    Ammunition is typically composed of a lead-based priming mixture which contributes to the characteristics most commonly used for the identification of gunshot residue (GSR). Due to the health risks often associated with lead, the use of lead-free primers in ammunitions is becoming more popular. Thus, the presence of GSR is becoming more difficult to discern based on the traditional means, i.e. the presence of lead (Pb), barium (Ba), and antimony (Sb). While research has been conducted on the differences between lead-based and lead-free muzzle discharge residue, few have researched other components of ammunition which may lead to other means of characterizing GSR. This research, therefore, covers that gap by focusing on the priming cup present in ammunition and the residue which may originate from it, that can contribute to muzzle discharge residue. In this study, a lead-based and a lead-free ammunition from four different manufacturers were chosen. The cartridges were fired using a Glock 17, 9mm Parabellum, collected post-fire, and subsequently de-primed resulting in the removal of the anvil. The GSR present on the anvils and cups was analyzed using scanning electron microscopy coupled with energy dispersive x-ray spectrometry (SEM-EDX). The data was then processed using unit vector analysis for normalization and analyzed using principal component analysis (PCA) and linear discriminant analysis (LDA). This data was then used to determine the components of the cartridge case which contribute to GSR and develop a method of characterization between lead-free and lead-based ammunition. Such a method will improve the detection of GSR by strengthening the criteria of identification. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Identifying persistent and characteristic features in firearm tool marks on cartridge cases

    Science.gov (United States)

    Ott, Daniel; Soons, Johannes; Thompson, Robert; Song, John

    2017-12-01

    Recent concerns about subjectivity in forensic firearm identification have motivated the development of algorithms to compare firearm tool marks that are imparted on ammunition and to generate quantitative measures of similarity. In this paper, we describe an algorithm that identifies impressed tool marks on a cartridge case that are both consistent between firings and contribute strongly to a surface similarity metric. The result is a representation of the tool mark topography that emphasizes both significant and persistent features across firings. This characteristic surface map is useful for understanding the variability and persistence of the tool marks created by a firearm and can provide improved discrimination between the comparison scores of samples fired from the same firearm and the scores of samples fired from different firearms. The algorithm also provides a convenient method for visualizing areas of similarity that may be useful in providing quantitative support for visual comparisons by trained examiners.

  20. OPTIMASI ISOLASI LIPASE INDIGENOUS BIJI KAKAO (Theobroma cacao L. The Optimizing of Isolation of Cocoa Bean Indogenous Lipase (Theobroma cacao L.

    Directory of Open Access Journals (Sweden)

    I D. G. Mayun Permana

    2012-05-01

    Full Text Available The aim of the research is to optimize the isolation method of cocoa bean lipase. The research is held by determining the position of lipase on cocoa bean, varying extraction medium and isolation process. The result shows that the lipase of cocoa bean is   cytosolic enzyme. The defatting process do not increase the lipase activity. Polyphenols inhibit the lipase activity, so that removal of the polyphenol will increase the activity. Blocking the polyphenol with polyvinilpolypirrolidone (PVPP will also increase the activity.The optimum consentration of PVPP is 8 %. The lipase activity will reach the highest when homogenized for 10 menit at 10,000 rpm. The best medium extraction for lipase isolation is 0.15 M phosphate buffer pH 7.5 containing sucrose 0.6 M and CaCl  1.0 mM.   ABSTRAK Penelitian ini bertujuan untuk mengoptimasi isolasi lipase indigenous biji kakao. Optimasi diawali dengan menentukan keberadaan lipase kemudian optimasi medium ekstraksi dan proses ekstraksi. Hasil penelitian menunjukkan bahwa lipase berada dalam sitosol. Penghilangan lemak tidak meningkatkan aktivitas lipase. Senyawa polifenol menghambat aktivitas lipase dan penghilangan polifenol dapat meningkatkan aktivitas lipase. Polyvinilpolypirrolidone (PVPP dapat menghambat polifenol sehingga dapat meningkatkan aktivitas lipase. Konsentrasi PVPP optimum adalah 8 % dari berat biji kakao. Proses homogenisasi optimum diperoleh dalam waktu 10 menit pada kecepatan 10.000 rpm. Medium ekstraksi untuk isolasi lipase biji kakao terbaik adalah bufer fosfat 0,15 M  dan pH 7,5 yang mengandung sukrosa 0,6 M dan 1,0 mM CaCl .

  1. A Modified Electrostatic Adsorption Apparatus for Latent Fingerprint Development on Unfired Cartridge Cases.

    Science.gov (United States)

    Xu, Jingyang; Zhang, Ziyuan; Zheng, Xiaochun; Bond, John W

    2017-05-01

    Visualization of latent fingerprints on metallic surfaces by the method of applying electrostatic charging and adsorption is considered as a promising chemical-free method, which has the merit of nondestruction, and is considered to be effective for some difficult situations such as aged fingerprint deposits or those exposed to environmental extremes. In fact, a portable electrostatic generator can be easily accessible in a local forensic technology laboratory, which is already widely used in the visualization of footwear impressions. In this study, a modified version of this electrostatic apparatus is proposed for latent fingerprint development and has shown great potential in visualizing fingerprints on metallic surfaces such as cartridge cases. Results indicate that this experimental arrangement can successfully develop aged latent fingerprints on metal surfaces, and we demonstrate its effectiveness compared with existing conventional fingerprint recovery methods. © 2016 American Academy of Forensic Sciences.

  2. Shale treatment

    Energy Technology Data Exchange (ETDEWEB)

    1941-03-03

    The charge of shale, coal, or the like, is placed in a cartridge which is inserted in a metal cylinder gas and/or steam heated to a temperature of between 300 to 500/sup 0/C is admitted through pipe and passes through two perforations through the charge which is held at a pressure of about .1 to 2 pounds per square inch and an out pipe together with evolved gases and vapours. A lid is clamped in position over the cartridge by means of an eye bolt and a nut.

  3. [Effectiveness of FTA Elute® indicating cartridge in combination with hybrid capture 2 for cervical cancer screening].

    Science.gov (United States)

    Chen, Feng; Zhang, Xi; Wang, Shaoming; Hu, Shangying; Chen, Wen; Zhao, Fanghui; He, Wei; Zhang, Yuqing; Qiao, Youlin

    2015-02-01

    To evaluate the effectiveness of FTA Elute® Cartridge (GE healthcare, Kent, UK) in combination with hybrid capture 2 (HC2) testing for cervical cancer screening. From May to June 2012, 412 women aged 25 to 65 years in Jiangxi Tonggu were enrolled in the study. We used pathological outcome as the gold standard, and the accuracy of the FTA card in combination with HC2 testing was investigated from both physician- and self-sampling, respectively. Physician sampling using the FTA card in combination with HC2 testing showed a comparable sensitivity (12/13) with the liquid based medium, but a higher specificity 69.5% (266/383) vs (77.8%, 298/383) (P FTA card in combination with HC2 testing with liquid based medium was 10/13 vs 8/13(P = 0.625) and (62.3%, 238/382) vs (75.7%, 289/382) (P FTA and liquid-based sampling medium was 86.1% (340/395) and 79.5% (314/395). For physician-collected samples used for HC2 testing to detect CIN2+, the accuracy of the FTA card was superior to that of the liquid-based medium (area under the receiver operating characteristic curve (AUC) = 0.898, 95%CI:0.838-0.958). FTA Elute® cartridge in combination with HC2 testing is a promising method of specimen transport for cervical cancer screening programs with a good precision.With further optimization, it could become an effective method for cervical cancer screening in various economic levels of areas.

  4. Thermal enhancement cartridge heater modified tritium hydride bed development, Part 2 - Experimental validation of key conceptual design features

    Energy Technology Data Exchange (ETDEWEB)

    Heroux, K.J.; Morgan, G.A. [Savannah River Laboratory, Aiken, SC (United States)

    2015-03-15

    The Thermal Enhancement Cartridge Heater Modified (TECH Mod) tritium hydride bed is an interim replacement for the first generation (Gen1) process hydride beds currently in service in the Savannah River Site (SRS) Tritium Facilities. 3 new features are implemented in the TECH Mod hydride bed prototype: internal electric cartridge heaters, porous divider plates, and copper foam discs. These modifications will enhance bed performance and reduce costs by improving bed activation and installation processes, in-bed accountability measurements, end-of-life bed removal, and He-3 recovery. A full-scale hydride bed test station was constructed at the Savannah River National Laboratory (SRNL) in order to evaluate the performance of the prototype TECH Mod hydride bed. Controlled hydrogen (H{sub 2}) absorption/ desorption experiments were conducted to validate that the conceptual design changes have no adverse effects on the gas transfer kinetics or H{sub 2} storage/release properties compared to those of the Gen1 bed. Inert gas expansions before, during, and after H{sub 2} flow tests were used to monitor changes in gas transfer rates with repeated hydriding/de-hydriding of the hydride material. The gas flow rates significantly decreased after initial hydriding of the material; however, minimal changes were observed after repeated cycling. The data presented herein confirm that the TECH Mod hydride bed would be a suitable replacement for the Gen1 bed with the added enhancements expected from the advanced design features. (authors)

  5. Comparison of steam sterilization conditions efficiency in the treatment of Infectious Health Care Waste.

    Science.gov (United States)

    Maamari, Olivia; Mouaffak, Lara; Kamel, Ramza; Brandam, Cedric; Lteif, Roger; Salameh, Dominique

    2016-03-01

    Many studies show that the treatment of Infectious Health Care Waste (IHCW) in steam sterilization devices at usual operating standards does not allow for proper treatment of Infectious Health Care Waste (IHCW). Including a grinding component before sterilization allows better waste sterilization, but any hard metal object in the waste can damage the shredder. The first objective of the study is to verify that efficient IHCW treatment can occur at standard operating parameters defined by the contact time-temperature couple in steam treatment systems without a pre-mixing/fragmenting or pre-shredding step. The second objective is to establish scientifically whether the standard operation conditions for a steam treatment system including a step of pre-mixing/fragmenting were sufficient to destroy the bacterial spores in IHCW known to be the most difficult to treat. Results show that for efficient sterilization of dialysis cartridges in a pilot 60L steam treatment system, the process would require more than 20 min at 144°C without a pre-mixing/fragmenting step. In a 720L steam treatment system including pre-mixing/fragmenting paddles, only 10 min at 144°C are required to sterilize IHCW proved to be sterilization challenges such as dialysis cartridges and diapers in normal conditions of rolling. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Rapid purification of radioiodinated peptides with Sep-Pak reversed phase cartridges and HPLC

    International Nuclear Information System (INIS)

    Miller, J.J.; Schultz, G.S.; Levy, R.S.

    1984-01-01

    A simple, rapid method is described for the purification of radioiodinated peptides for use in radioimmuno- and in radioreceptor assays. Iodinated reaction mixtures are applied directly onto Sep-Pak disposable, reversed phase cartridges equilibrated with phosphate buffer. Unreacted 125-iodide and other non-peptide reaction components are eluted with buffer. The peptide fraction is then eluted with 70% buffer:30% acetonitrile. The peptide fraction is further purified by reversed phase high pressure liquid chromatography to separate the native peptide and the mono- and diiodo-derivatives. In this study the method is used to prepare 125-iodide-labeled monoiodo-leucine enkephalin and monoiodo-angiotensin II, which are free of the parent peptides and diiodo-derivatives and are of maximum obtainable specific radioactivity. The usefulness of these labeled peptides in radioimmuno- and radioreceptor assays is demonstrated by their binding to specific antibodies and receptors, respectively. (author)

  7. A new screening method for amphetamine and methamphetamine using dansyl chloride derivatization and cartridge fluorescence.

    Science.gov (United States)

    Yamada, H; Ikeda-Wada, S; Oguri, K

    1998-07-01

    A new screening method for amphetamines was developed. It consists of derivatization with dansyl chloride, extraction of the derivative using a Sep-Pak C18 or a Bond Elut C18, solid phase extraction columns, and visualization of the fluorescence of the cartridge. A control test using drug-free urine showed no fluorescence. Amphetamine, methamphetamine and the methylenedioxy derivatives exhibited strong fluorescence, while related compounds, such as N-ethylamphetamine and fenetylline, were negative or weakly positive. The disadvantage of the present method is that it is a multi-step procedure and 20-30 min is required for screening. However, since it has a different specificity from the widely used immunochemical technique, it is suggested to be a useful screen for amphetamines.

  8. Release of natural radionuclides in the Czech Republic - from water treatment plants where water from underground water sources is treated

    International Nuclear Information System (INIS)

    Sinaglova, R.

    2014-01-01

    In this abstract author deals with the treatment of drinking water in the Czech Republic with removing of natural radionuclides as well as with treatment of filter cartridges. The advantage of these technologies is that flushing is not required so no wastewater occurs. Used ion exchangers with higher content of uranium are processed in the chemical treatment of uranium ores, managed by DIAMO, state enterprise. (authors)

  9. CSER 95-014: Criticality storage category for K Basin spent cartridge filters in ECOROK casks at central waste complex

    International Nuclear Information System (INIS)

    Miller, E.M.

    1996-01-01

    This CSER justifies storing K Basin spent cartridge filters in ECOROK 25-11 casks with liners under the limits in an existing criticality prevention specification, CPS-SW-149-00002, Rev./Mod. B-1, because the worst case fissionable material inventory is less then 1/2 the CPS limit and the cask is larger than allowed containers, the cask and liner have adequate iron content to meet the CPS requirements, and the cask concrete walls are thick enough to isolate the fissionable contents of each cask from neutron interaction with fissionable material external to each cask

  10. Adsorption of various antimicrobial agents to endotoxin removal polymyxin-B immobilized fiber (Toraymyxin®). Part 2: Adsorption of two drugs to Toraymyxin PMX-20R cartridges.

    Science.gov (United States)

    Shimokawa, Ken-ichi; Takakuwa, Ryotaro; Wada, Yuko; Yamazaki, Noriko; Ishii, Fumiyoshi

    2013-01-01

    In our previous study, the degree of adsorption of 9 representative antimicrobial agents to Toraymyxin(®) PMX-F sheets was quantitatively evaluated. As a result, the adsorption rate was 22.1% for Linezolid in the presence of serum. Therefore, we investigated whether two types of antimicrobial agents (Ciprofroxacin and Linezolid) can be better adsorbed on PMX-F sheets. When the number of PMX-F sheets was increased in a step wise manner, specifically 2, 4, 6, 8 and 12, the adsorption rate increased linearly. In addition, the adsorption to polymyxin-B immobilized fiber (Toraymyxin(®) PMX-20R) cartridges, widely used to remove endotoxins from circulating blood in the treatment of sepsis, was quantitatively evaluated. As a result, in the presence of serum, Linezolid showed adsorption to PMX-20R, and the adsorption rate after 2h was 54.5%, and that after 4h was 65.8%. The results of this study suggest the necessity of monitoring blood antimicrobial concentration during treatment for sepsis with Linezolid, which showed adsorption to PMX-20R in an environment close to a clinical environment. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Science.gov (United States)

    Catarino, Rosa; Vassilakos, Pierre; Bilancioni, Aline; Vanden Eynde, Mathieu; Meyer-Hamme, Ulrike; Menoud, Pierre-Alain; Guerry, Frédéric; Petignat, Patrick

    2015-01-01

    Human papillomavirus (HPV) self-sampling (self-HPV) is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab. A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY) or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA). After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET). HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic. HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2) detected by s-DRY, 56.2% (95%CI: 47.6-64.4) by Dr-WET, and 54.6% (95%CI: 46.1-62.9) by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34), and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56). Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+) were: 64.0% (95%CI: 44.5-79.8) for s-FTA, 84.6% (95%CI: 66.5-93.9) for s-DRY, and 76.9% (95%CI: 58.0-89.0) for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%). Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD)/per card vs. ~1 USD/per swab). Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA. International Standard Randomized Controlled Trial Number (ISRCTN): 43310942.

  12. Mining run-off gets a treatment

    International Nuclear Information System (INIS)

    Pichon, Max

    2013-01-01

    Full text: Engineering company GHD has implemented an innovative multi- barrier storm water treatment system for a major milling company at the Port of Townsville. The technology economically filters stormwater and is effective for a broad range of contaminants including oil, grease, soluble nutrients and heavy metals. GHD's industrial water and coal seam gas business development leader, Kostas Athanasiadis, created StormDMT, a configuration of inexpensive filter media in a cartridge that cost-effectively removes heavy metals and other dissolved contaminants. He said there was growing recognition of the need to protect receiving waterways and to address water scarcity through measures such as stormwater harvesting. “However, there are few stormwater treatment technologies currently available to effectively and economically remove these contaminants both in particulate and soluble forms, to desirable levels,” he said. GHD carried out a trial at the site in collaboration with the client's engineering, environmental and operational teams. The filter exceeded anticipated performance and the client has adopted a site-wide solution based on the technology. The StormDMT stormwater filter system design incorporates a filtering system (cartridge or other types of filtering configurations) that contains a combination of filter media, including polypropylene flakes to remove oil and grease and particulate-bound contaminants. It also features a zeolite named clinoptilolite to remove positive charged dissolved contaminants such as heavy metals and ammonium nitrogen. Clinoptilolite has been chemically conditioned to maximise its operational ion exchange capacity. Finally, laterite removes negative charged contaminants such as phosphate, nitrate and arsenic as well as heavy metals that have broken through the clinotpilolite layer. One of the key advantages of the StormDMT technology is the low discharge levels it is capable of achieving or dissolved nutrients and

  13. Advances in HTGR Wastewater Treatment System Design

    International Nuclear Information System (INIS)

    Li Junfeng; Qiu Yu; Wang Jianlong; Jia Fei

    2014-01-01

    The source terms of radioactive wastewater from HTR-PM were introduced. Concentration process should be used to reduce volume. A radioactive wastewater treatment system was designed by using Disc tubular reverse osmosis (DTRO) membrane system. The pretreatment system was simplify by using a cartridge filter. A three-stage membrane system was built. The operated characters to treat low and intermediate radioactive waste water were studied. A concentration rates of 25-50 is reached. The decontamination factor of the membrane system can reach 30-100. (author)

  14. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Comparison of the Usefulness of SPE Cartridges for the Determination of β-Blockers and β-Agonists (Basic Drugs in Environmental Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Magda Caban

    2015-01-01

    Full Text Available Even though the methodology used for the determination of β-blockers and β-agonists in environmental samples is based mainly on solid-phase extraction (SPE and gas chromatography or liquid chromatography with mass spectrometric detection, the available literature data on the applied SPE procedures is rather sparse. In this paper such comparison is presented. Moreover, the usefulness of the eight SPE cartridges for the determination of five β-blockers (acebutolol, atenolol, metoprolol, nadolol, and propranolol and two β-agonists (salbutamol and terbutaline in environmental aqueous samples using GC techniques is tested. Among them, three (the trifunction sorbent Strata Screen C, the copolymers LiChrolut EN, and the functionalized copolymer Isolute ENV+ were used for the first time for this purpose. It was confirmed that polystyrene-divinylbenzene-N-vinylpyrrolidone copolymers (PS-DVB-VP, Strata-X, and Oasis HLB cartridges have a better potential than a cation-exchange sorbent for the extraction of the target drugs from environmental water samples. However, it should be stressed out that the direct application of the tested SPE conditions for the analysis of real environmental water samples is not possible, and such parameters, like volume of loading sample, appropriate solvents for washing and elution steps, and so forth, must be optimized again in order to achieve satisfactory recovery values for the target compounds.

  16. Prevalence of Ex Vivo High On-treatment Platelet Reactivity on Antiplatelet Therapy after Transient Ischemic Attack or Ischemic Stroke on the PFA-100(®) and VerifyNow(®).

    LENUS (Irish Health Repository)

    Kinsella, Justin A

    2012-09-12

    BACKGROUND: The prevalence of ex vivo high on-treatment platelet reactivity (HTPR) to commonly prescribed antiplatelet regimens after transient ischemic attack (TIA) or ischemic stroke is uncertain. METHODS: Platelet function inhibition was simultaneously assessed with modified light transmission aggregometry (VerifyNow; Accumetrics Inc, San Diego, CA) and with a moderately high shear stress platelet function analyzer (PFA-100; Siemens Medical Solutions USA, Inc, Malvern, PA) in a pilot, cross-sectional study of TIA or ischemic stroke patients. Patients were assessed on aspirin-dipyridamole combination therapy (n = 51) or clopidogrel monotherapy (n = 25). RESULTS: On the VerifyNow, HTPR on aspirin was identified in 4 of 51 patients (8%) on aspirin-dipyridamole combination therapy (≥550 aspirin reaction units on the aspirin cartridge). Eleven of 25 (44%) patients had HTPR on clopidogrel (≥194 P2Y12 reaction units on the P2Y12 cartridge). On the PFA-100, 21 of 51 patients (41%) on aspirin-dipyridamole combination therapy had HTPR on the collagen-epinephrine (C-EPI) cartridge. Twenty-three of 25 patients (92%) on clopidogrel had HTPR on the collagen-adenosine diphosphate (C-ADP) cartridge. The proportion of patients with antiplatelet HTPR was lower on the VerifyNow than PFA-100 in patients on both regimens (P < .001). CONCLUSIONS: The prevalence of ex vivo antiplatelet HTPR after TIA or ischemic stroke is markedly influenced by the method used to assess platelet reactivity. The PFA-100 C-ADP cartridge is not sensitive at detecting the antiplatelet effects of clopidogrel ex vivo. Larger prospective studies with the VerifyNow and with the PFA-100 C-EPI and recently released Innovance PFA P2Y cartridges (Siemens Medical Solutions USA, Inc) in addition to newer tests of platelet function are warranted to assess whether platelet function monitoring predicts clinical outcome in ischemic cerebrovascular disease.

  17. [Determination of metformin hydrochloride, melamine and dicyandiamide in metformin hydrochloride preparations by tandem dual solid phase extraction cartridges-high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry].

    Science.gov (United States)

    Zhou, Yanfen; Wang, Fanghuan; Wang, Zelan; Zhan, Haijuan; Liu, Wanyi; Meng, Zhe

    2018-02-08

    A method for the confirmation and quantification of metformin hydrochloride and its relative substances melamine and dicyandiamide using tandem dual solid phase extraction (SPE) cartridges and high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry (HPLC-ESI-MS n ) was developed. The samples were extracted with anhydrous ethanol containing 0.1% (v/v) acetic acid under ultrasound-assisted conditions. The extracts were concentrated and purified using Cleanert PCX and C18 tandem dual solid phase extraction cartridges, and eluted with 5% (v/v) ammonia methanol solution. The separation was performed on a Kromasil-C18 column (100 mm×4.6 mm, 3.5 μm) with gradient elution. The detection was performed in selected ion monitoring (SIM) mode using electrospray ionization multi-stage mass spectrometry. The external standard method was used for quantification. The extraction solvents, types of SPE cartridges and eluents were optimized by comparing the recoveries under different conditions. The results showed that the detector response of each target compound was linear in corresponding mass concentration ranges with the correlation coefficients ( r 2 ) ≥ 0.9992. The limits of detection (LODs) and the limits of quantification (LOQs) of the three analytes were 1.48-13.61 μg/kg and 5.96-45.67 μg/kg, respectively. The recoveries of the three analytes were 65.02%-118.33% spiked at low, medium and high levels. The relative standard deviations (RSDs) were no more than 13.41%. The method is reliable, easy, and has a better purification effect. The method can be applied to the routine analysis of metformin hydrochloride and its relative substances melamine and dicyandiamide in different preparations of metformin hydrochloride.

  18. Influence of closure, phenolic levels and microoxygenation on Cabernet Sauvignon wine composition after 5 years' bottle storage.

    Science.gov (United States)

    Han, Guomin; Ugliano, Maurizio; Currie, Bruce; Vidal, Stéphane; Diéval, Jean-Baptiste; Waterhouse, Andrew L

    2015-01-01

    Wine aging is generally limited by the amount of oxidation, which is dependent on the amount of oxygen entering via the closure. Cabernet Sauvignon wine is well known for its high concentration of tannin, making it an ideal red wine for aging. The impact of closure type after 5 years' bottle aging has been investigated on a 2007 Cabernet Sauvignon red wine, treated with or without polyvinylpolypyrrolidone (PVPP) and micro-oxygenation (Mox). Two oxygen transfer rate (OTR) conditions (16 and 5 µg per day) into 375 mL bottles were obtained by using different synthetic stoppers. Color was evaluated by UV-visible spectrophotometry, carbonyls by 2,4-dinitrophenylhydrazine derivatization, phenolics by high-performance liquid chromatography and sulfur dioxide by the aspiration method. Closure type strongly influenced color parameters involving SO2 bleaching and some phenolics, particularly quercetin, were affected, but there was little effect on carbonyls other than acetaldehyde. PVPP treatment afforded wines with the lowest levels of phenolics and color density, but highest acetaldehyde. Few effects of Mox could be detected. Closure OTR strongly affects sulfur dioxide levels - the primary antioxidant in wine - in aged wine, but phenolic levels substantially alter the secondary reactions of oxidative aging. © 2014 Society of Chemical Industry.

  19. Effects of fining on phenolic compounds and colour of red wine obtained with addition of increased amounts of grape solid phase in pomace

    Directory of Open Access Journals (Sweden)

    Puškaš Vladimir S.

    2012-01-01

    Full Text Available The purpose of this work is to study the effect of grape pomace enrichment in solid phase (stems and seeds on phenolic compounds and colour stability of obtained red wines, before and after use of different fining agents. Results have shown increase in total phenols and flavan-3-ols content after grape solid phase addition. On the other hand, decrease in anthocyanins content has generally been recorded in all wine samples except in wines obtained with addition of 40 g/l of seeds during maceration. Stems addition caused decrease in colour intensity while addition of seeds has increased this colour parameter. The use of four fining agents (albumin, gelatine, bentonite and PVPP has been investigated and compared, especially in terms of their influence on potential stabilization effect of grape solid phase on wine colour. Fined wines tended to have considerably lower anthocyanin and flavan-3-ol levels, especially in the case of gelatine and PVPP treatment (decrease up to 60 and 70%, respectively. In the case of chromatic parameters, used fining agents caused colour intensity decrease but it is important to emphasize that their values, after fining, are still as high as expected from red wine. This can be explained by the stabilization effect of increased flavan-3-ols content.

  20. Sugar microanalysis by HPLC with benzoylation: improvement via introduction of a C-8 cartridge and a high efficiency ODS column.

    Science.gov (United States)

    Miyagi, Michiko; Yokoyama, Hirokazu; Hibi, Toshifumi

    2007-07-01

    An HPLC protocol for sugar microanalysis based on the formation of ultraviolet-absorbing benzoyl chloride derivatives was improved. Here, samples were prepared with a C-8 cartridge and analyzed with a high efficiency ODS column, in which porous spherical silica particles 3 microm in diameter were packed. These devices allowed us to simultaneously quantify multiple sugars and sugar alcohols up to 10 ng/ml and to provide satisfactory separations of some sugars, such as fructose and myo-inositol and sorbitol and mannitol. This protocol, which does not require special apparatuses, should become a powerful tool in sugar research.

  1. Randomized Comparison of Two Vaginal Self-Sampling Methods for Human Papillomavirus Detection: Dry Swab versus FTA Cartridge.

    Directory of Open Access Journals (Sweden)

    Rosa Catarino

    Full Text Available Human papillomavirus (HPV self-sampling (self-HPV is valuable in cervical cancer screening. HPV testing is usually performed on physician-collected cervical smears stored in liquid-based medium. Dry filters and swabs are an alternative. We evaluated the adequacy of self-HPV using two dry storage and transport devices, the FTA cartridge and swab.A total of 130 women performed two consecutive self-HPV samples. Randomization determined which of the two tests was performed first: self-HPV using dry swabs (s-DRY or vaginal specimen collection using a cytobrush applied to an FTA cartridge (s-FTA. After self-HPV, a physician collected a cervical sample using liquid-based medium (Dr-WET. HPV types were identified by real-time PCR. Agreement between collection methods was measured using the kappa statistic.HPV prevalence for high-risk types was 62.3% (95%CI: 53.7-70.2 detected by s-DRY, 56.2% (95%CI: 47.6-64.4 by Dr-WET, and 54.6% (95%CI: 46.1-62.9 by s-FTA. There was overall agreement of 70.8% between s-FTA and s-DRY samples (kappa = 0.34, and of 82.3% between self-HPV and Dr-WET samples (kappa = 0.56. Detection sensitivities for low-grade squamous intraepithelial lesion or worse (LSIL+ were: 64.0% (95%CI: 44.5-79.8 for s-FTA, 84.6% (95%CI: 66.5-93.9 for s-DRY, and 76.9% (95%CI: 58.0-89.0 for Dr-WET. The preferred self-collection method among patients was s-DRY (40.8% vs. 15.4%. Regarding costs, FTA card was five times more expensive than the swab (~5 US dollars (USD/per card vs. ~1 USD/per swab.Self-HPV using dry swabs is sensitive for detecting LSIL+ and less expensive than s-FTA.International Standard Randomized Controlled Trial Number (ISRCTN: 43310942.

  2. Improvements of the sensitivity of burst cartridge detection; Amelioration du seuil de detection des ruptures de gaine

    Energy Technology Data Exchange (ETDEWEB)

    Vasnier, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    I - Special tests for improving the sensitivity of burst cartridge detection equipment in power reactors II - Scintillator purge-flow tests using aged gas in the B.C.D. /E.D.F. 2 Summary. - The first part of this report describes the tests carried out on fission product detectors by a process in which gas is continuously injected in front of the scintillator. Using this system, the background is reduced and perturbations caused by pneumatic switches on the prospecting circuits are eliminated. The quality of the signals thus obtained permits better processing of the data and thus leads to a possible improvement in the sensitivity of burst cartridge detection. The second part gives results of tests carried out with both fresh and aged gases, the economic advantage of the latter being that it permits recycling through the reactor. Reduction of the background is less pronounced but the advantage of the stable signals is conserved. (author) [French] I - Essais speciaux pour ameliorer le seuil de detection des installations de D.R.G. des reacteurs de puissance II- Essais de balayage sous scintillateur avec gaz vieilli a la D.R.G. /E.D.F. 2 Sommaire. - La premiere partie de ce rapport decrit les essais effectues sur les detecteurs de produits de fission par un procede d'injection continue de gaz sous le scintillateur. Grace a ce systeme on obtient une reduction du bruit de fond et l'elimination des perturbations causees par les commutations pneumatiques des circuits de prospection. La qualite des signaux obtenus ainsi permet un meilleur traitement des informations d'ou une amelioration possible du seuil de detection des ruptures de gaines. La seconde partie donne les resultats d'essais effectues avec du gaz propre et vieilli, l'utilisation de ce dernier presentant l'avantage economique d'etre recycle du reacteur. La reduction du bruit de fond est moins importante mais on conserve l'avantage de la stabilisation des signaux. (auteur)

  3. Microfluidic impact printer with interchangeable cartridges for versatile non-contact multiplexed micropatterning.

    Science.gov (United States)

    Ding, Yuzhe; Huang, Eric; Lam, Kit S; Pan, Tingrui

    2013-05-21

    Biopatterning has been increasingly used for well-defined cellular microenvironment, patterned surface topology, and guided biological cues; however, it meets challenges on biocompatibility, thermal and chemical sensitivity, as well as limited availability of reagents. In this paper, we aim at combining the desired features from non-contact inkjet printing and dot-matrix impact printing to establish a versatile multiplexed micropatterning platform, referred to as Microfluidic Impact Printer (MI-Printer), for emerging biomedical applications. Using this platform, we can achieve the distinct features of no cross-contamination, sub-microliter ink loading with a minimal dead volume, high-throughput printing, biocompatible non-contact processing, sequential patterning with self-alignment, wide adaptability for complex media (e.g., cell suspension or colloidal solutions), interchangeable/disposable cartridge design, and simple assembly and configuration, all highly desirable towards laboratory-based research and development. Specifically, the printing resolution of the MI-printer platform has been experimentally characterized and theoretically analysed. Optimal printing resolution of 80 μm has been repeatedly obtained. Furthermore, two useful functions of the MI-printer, multiplexed printing and combinatorial printing, have been experimentally demonstrated with less than 10 μm misalignment. Moreover, molecular and biological patterning, utilizing the multiplexed and combinatorial printing, has been implemented to illustrate the utility of this versatile printing technique for emerging biomedical applications.

  4. Hydraulic optimization and modeling of hydro-cyclone-systems for treatment and purification of any kind of waters

    Science.gov (United States)

    Spangemacher, Lars; Fröhlich, Siegmund; Buse, Hauke

    2017-11-01

    Water is an indispensable resource for many purposes and good drinking water quality is essential for mankind. This article is supposed to show the need for mobile water treatment systems and therefore to give an overview of different mobile drinking water systems and the technologies available for obtaining good water quality. The aim is to develop a simple to operate water treatment system with few processing stages such as multi-cyclone-cartridge and reverse osmosis with energy recuperation, while the focus is set on modeling and optimizing of hydrocyclone systems as the first treatment stage.

  5. The effectiveness of polyethylene glycol (PEG) and polyvinyl ...

    African Journals Online (AJOL)

    mahlos

    2012-05-29

    May 29, 2012 ... Key words: Acetone, tannin, polyethylene glycol (PEG), polyvinyl polypyrrolidone (PVPP). ... hydrolysable tannins may occur in the same plant. ..... Rev. Food Sci. Nutr., 38: 421-464. Cornell. (2000). Tannins: Chemical analysis.

  6. Hydraulic optimization and modeling of hydro-cyclone-systems for treatment and purification of any kind of waters

    Directory of Open Access Journals (Sweden)

    Spangemacher Lars

    2017-01-01

    Full Text Available Water is an indispensable resource for many purposes and good drinking water quality is essential for mankind. This article is supposed to show the need for mobile water treatment systems and therefore to give an overview of different mobile drinking water systems and the technologies available for obtaining good water quality. The aim is to develop a simple to operate water treatment system with few processing stages such as multi-cyclone-cartridge and reverse osmosis with energy recuperation, while the focus is set on modeling and optimizing of hydrocyclone systems as the first treatment stage.

  7. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    Science.gov (United States)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  8. Effect of six tropical tanniferous plant extracts on larval exsheathment of Haemonchus contortus Efeito de seis extratos de plantas taniníferas tropicais sobre o desembainhamento larvar de Haemochus contortus

    Directory of Open Access Journals (Sweden)

    Lorena Mayana Beserra de Oliveira

    2011-06-01

    Full Text Available Tanniferous plants represent a promising alternative for controlling gastrointestinal nematodes of small ruminants. This experiment evaluated the effects of extracts from the leaf and stem of Anadenanthera colubrina, Leucaena leucocephala and Mimosa tenuiflora on larval exsheathment of Haemonchus contortus in vitro and verified the role of tannins in this process. Third-stage larvae of H. contortus were incubated with extracts for 3 hours and were exposed to sodium hypochlorite solution. The extracts were tested at 300 µg.mL-1 and accompanied by controls: phosphate buffer solution (PBS and polyvinyl polypyrrolidone (PVPP. The larval exsheathment was evaluated for 60 minutes, and the results were subjected to the Kruskal-Wallis test (p 0.05, except for L. leucocephala and M. tenuiflora leaf extracts. However, pre-incubation with PVPP of these two extracts significantly changed larval exsheathment when compared to the non-treated extracts (p Plantas taniníferas representam uma promissora alternativa de controle dos nematóides gastrintestinais de pequenos ruminantes. Esse experimento avaliou in vitro os efeitos dos extratos das folhas e caules de Anadenanthera colubrina, Leucaena leucocephala e Mimosa tenuiflora sobre o desembainhamento larvar de Haemonchus contortus e verificou o papel dos taninos nesse processo. Larvas de terceiro estádio de H. contortus foram incubadas com 300 µg.mL-1 de extrato por 3 horas e expostas a uma solução de hipoclorito de sódio. O ensaio foi acompanhado por controles: solução salina tamponada com fosfato (PBS e polivinilpolipirrolidona (PVPP. O desembainhamento larvar foi avaliado durante 60 minutos e os resultados submetidos ao teste Kruskal-Wallis (p 0,05, exceto nos extratos das folhas de L. leucocephala e M. tenuiflora. Entretanto, a pré-incubação desses dois extratos com PVPP alterou significativamente o desembainhamento quando comparado com extratos não-tratados (p < 0,05. Esses resultados sugerem

  9. Comparison of RNA Extraction Methods for the Identification of Grapevine fan leaf virus

    Directory of Open Access Journals (Sweden)

    Z. Gholampour

    2016-06-01

    isolate of the virus (Zakiaghl and Izadpanah 2003. The RNA isolation protocols of Triazol extraction, high salt phenol-chloroform extraction (Rowhani et al. 1993, RNA extraction using silicon dioxide, Silica (Boom et al 1990, CTAB-PVPP extraction and a commercial RNA isolation kit were used in the study. In all protocols, 50 mg leaf samples were used. The quality and purity of the extracted RNA were determined using spectrophotometry. For purity assessment, the absorbance for the A260/280 and A260/230 ratios was taking in water. RT-PCR was performed using DetF (5´-CGGCAGACTGGCAAGCTGT-3´ and DetR (5´-GGTCCAGTTTAATTGCCATCCA-3´ specific primer pair amplified 1000 bp of the coat protein gene of GFLV. PCR products were run on 1% agarose gel containing 0.5 µg/ml DNA Green Viewer, and visualized under UV irradiation. Results: There were large differences in the amount of RNA extracted per gram of tissue depending on the protocol used. The commercial kit, CTAB-PVPP and TRIzol methods gave the highest yields in micrograms RNA per gram fresh weight (235-300 μg/g. In contrast, the application of Silica gave the lowest yield (11 μg/g. The high salt phenol-chloroform method gave a moderate yield of over 77 μg/g. In this respect, the CTAB-PVPP method provides the highest yield of RNA. RNA quality was assessed by three methods: A260/280, A260/230 and ability to produce RT-PCR products. A260/280 ratios indicate the level of protein contamination in the preparation. The commercial kit, CTAB-PVPP, TRIzol and high salt phenol-chloroform methods gave RNA with very low amounts of protein contamination. In contrast, RNA isolated by the Silica showed more protein contamination, as indicated by the lower A260/280 ratios. A260/230 ratios are used to assess the level of contamination by polysaccharides and polyphenols. The high salt phenol-chloroform method yielded RNA that was contaminated with polysaccharides. In contrast, the CTAB-PVPP, TRIzol methods yielded RNA with very little

  10. Direct preparation of a graphene oxide modified monolith in a glass syringe as a solid-phase extraction cartridge for the extraction of quaternary ammonium alkaloids from Chinese patent medicine.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Licheng; Wang, Shuai; Li, Yijing; Guo, Yong

    2017-11-01

    Packed cartridges have been widely used in solid-phase extraction. However, there are still some drawbacks, such as they are blocked easily and the method is time-consuming. In view of the advantages of monoliths, a monolithic extraction material has been directly synthesized in a glass syringe without any gap between the monolith and syringe inner wall. The monolithic syringe was modified with graphene oxide by loading graphene oxide dispersion onto it. The content of graphene oxide and the surface topography of the monolith have been evaluated by elemental analysis and scanning electron microscopy, respectively, which confirmed the successful modification. This prepared graphene oxide-modified monolithic syringe was directly used as a traditional solid-phase extraction cartridge. As expected, it shows good permeability and excellent capability for the extraction of quaternary ammonium alkaloids. The sample loading velocity (1-6 mL/min) does not affect the recovery. Under the optimal conditions, good linearities (R = 0.9992-0.9998) were obtained for five quaternary ammonium alkaloids, and the limits of detection and quantification were 0.5-1 and 1-2 μg/L, respectively. The proposed method was successfully applied for the analysis of quaternary ammonium alkaloids in Chinese patent medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Overview of Treatment and Conditioning Practices in Goesgen NPP

    International Nuclear Information System (INIS)

    Aebi, Patrick

    2008-01-01

    Radioactive waste of the Goesgen Nuclear Power Plant is collected and stored in an appropriate form for external conditioning or for direct in-house conditioning procedures. Different waste treatment and conditioning technologies have been used since plant start up in 1979. The main conditioning technology used in-house is bituminization. Reactor internal components, contaminated filter elements of cooling circuits or radioactive sludge from the liquid waste tanks have been treated by dedicated equipment and methods. These methods are under water cutting and manipulation of core components, remote dismantling and compressing of filter elements into cartridges or filtration of sludge with a one-chamber filtration system. (authors)

  12. Construction of a mutagenesis cartridge for poliovirus genome-linked viral protein: isolation and characterization of viable and nonviable mutants

    International Nuclear Information System (INIS)

    Kuhn, R.J.; Tada, H.; Ypma-Wong, M.F.; Dunn, J.J.; Semler, B.L.; Wimmer, E.

    1988-01-01

    By following a strategy of genetic analysis of poliovirus, the authors have constructed a synthetic mutagenesis cartridge spanning the genome-linked viral protein coding region and flanking cleavage sites in an infectious cDNA clone of the type I (Mahoney) genome. The insertion of new restriction sites within the infectious clone has allowed them to replace the wild-type sequences with short complementary pairs of synthetic oligonucleotides containing various mutations. A set of mutations have been made that create methionine codons within the genome-linked viral protein region. The resulting viruses have growth characteristics similar to wild type. Experiments that led to an alteration of the tyrosine residue responsible for the linkage to RNA have resulted in nonviable virus. In one mutant, proteolytic processing assayed in vitro appeared unimpaired by the mutation. They suggest that the position of the tyrosine residue is important for genome-linked viral protein function(s)

  13. Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge

    Directory of Open Access Journals (Sweden)

    Akira Homma

    1974-01-01

    Full Text Available Quantitative method of viral pollution determination for large volume of water using ferric hydroxide gel impregnated on the surface of glassfibre cartridge filter. The use of ferric hydroxide gel, impregnated on the surface of glassfibre cartridge filter enable us to recover 62.5% of virus (Poliomylitis type I, Lsc strain exsogeneously added to 400 liters of tap-water. The virus concentrator system consists of four cartridge filters, in which the three first one are clarifiers, where the contaminants are removed physically, without significant virus loss at this stage. The last cartridge filter is impregnated with ferric hydroxide gel, where the virus is adsorbed. After the required volume of water has been processed, the last filter is removed from the system and the viruses are recovered from the gel, using 1 liter of glycine/NaOH buffer, at pH 11. Immediately the eluate is clarified through series of cellulose acetate membranes mounted in a 142mm Millipore filter. For the second step of virus concentration, HC1 1N is added slowly to the eluate to achieve pH 3.5-4. MgC1, is added to give a final concentration of 0.05M and the viruses are readsorbed on a 0.45 , porosity (HA cellulose acetate membrane, mounted in a 90 mm Millipore filter. The viruses are recovered using the same eluent plus 10% of fetal calf serum, to a final volume of 3 ml. In this way, it was possible to concentrate virus from 400 liters of tap-water, into 1 liter in the first stage of virus concentration and just to 3 ml of final volume in a second step. The efficiency, simplicity and low operational cost, provded by the method, make it feasible to study viral pollution of recreational and tap-water sources.Relata-se o emprego de um concentrador portátil, o qual se mostrou capaz de recuperar 62,5% dos vírus (Polio I, amostra Lsc experimentalmente dispersos em 400 litros de água, os quais foram reduzidos a 3 ml. O sistema concentrador de vírus é composto de quatro

  14. Rapid and simple detection of foot-and-mouth disease virus: Evaluation of a cartridge-based molecular detection system for use in basic laboratories.

    Science.gov (United States)

    Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L

    2018-04-01

    Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases

  15. A Fully Automated Radiosynthesis of [18F]Fluoroethyl-Diprenorphine on a Single Module by Use of SPE Cartridges for Preparation of High Quality 2-[18F]Fluoroethyl Tosylate

    Directory of Open Access Journals (Sweden)

    Gjermund Henriksen

    2013-06-01

    Full Text Available We have developed a new method for automated production of 2-[18F]fluoroethyl tosylate ([18F]FETos that enables 18F-alkylation to provide PET tracers with high chemical purity. The method is based on the removal of excess ethylene glycol bistosylate precursor by precipitation and subsequent filtration and purification of the filtrate by means of solid phase extraction cartridges (SPE. The method is integrated to a single synthesis module and thereby provides the advantage over previous methods of not requiring HPLC purification, as demonstrated by the full radiosynthesis of the potent opioid receptor PET tracer [18F]fluoroethyldiprenorphine.

  16. "1"4CO_2 processing using an improved and robust molecular sieve cartridge

    International Nuclear Information System (INIS)

    Wotte, Anja; Wordell-Dietrich, Patrick; Wacker, Lukas; Don, Axel; Rethemeyer, Janet

    2017-01-01

    Radiocarbon ("1"4C) analysis on CO_2 can provide valuable information on the carbon cycle as different carbon pools differ in their "1"4C signature. While fresh, biogenic carbon shows atmospheric "1"4C concentrations, fossil carbon is "1"4C free. As shown in previous studies, CO_2 can be collected for "1"4C analysis using molecular sieve cartridges (MSC). These devices have previously been made of plastic and glass, which can easily be damaged during transport. We thus constructed a robust MSC suitable for field application under tough conditions or in remote areas, which is entirely made of stainless steel. The new MSC should also be tight over several months to allow long sampling campaigns and transport times, which was proven by a one year storage test. The reliability of the "1"4CO_2 results obtained with the MSC was evaluated by detailed tests of different procedures to clean the molecular sieve (zeolite type 13X) and for the adsorption and desorption of CO_2 from the zeolite using a vacuum rig. We show that the "1"4CO_2 results are not affected by any contamination of modern or fossil origin, cross contamination from previous samples, and by carbon isotopic fractionation. In addition, we evaluated the direct CO_2 transfer from the MSC into the automatic graphitization equipment AGE with the subsequent "1"4C AMS analysis as graphite. This semi-automatic approach can be fully automated in the future, which would allow a high sample throughput. We obtained very promising, low blank values between 0.0018 and 0.0028 F"1"4C (equivalent to 50,800 and 47,200 yrs BP), which are within the analytical background and lower than results obtained in previous studies.

  17. F/H Effluent Treatment Facility filtration upgrade alternative evaluations overview

    Energy Technology Data Exchange (ETDEWEB)

    Miles, W.C. Jr.; Poirier, M.R.; Brown, D.F.

    1992-01-01

    The F/H Effluent Treatment Facility (ETF) at the Savannah River Site (SRS) was designed to treat process wastewater from the 200-F/H Production Facilities (routine wastewater) as well as intermittent flows from the F/H Retention Basins and F/H Cooling Water Basins (nonroutine wastewater). Since start-up of the ETF at SRS in 1988, the treatment process has experienced difficulties processing routine and nonroutine wastewater. Studies have identified high bacteria and bacterial decomposition products in the wastewater as the cause for excessive fouling of the filtration system. In order to meet Waste Management requirements for the treatment of processed wastewater, an upgrade of the ETF filtration system is being developed. This upgrade must be able to process the nonroutine wastewater at design capacity. As a result, a study of alternative filter technologies was conducted utilizing simulated wastewater. The simulated wastewater tests have been completed. Three filter technologies, centrifugal polymeric ultrafilters, tubular polymeric ultrafilters, and backwashable cartridge filters have been selected for further evaluation utilizing actual ETF wastewater.

  18. F/H Effluent Treatment Facility filtration upgrade alternative evaluations overview

    Energy Technology Data Exchange (ETDEWEB)

    Miles, W.C. Jr.; Poirier, M.R.; Brown, D.F.

    1992-07-01

    The F/H Effluent Treatment Facility (ETF) at the Savannah River Site (SRS) was designed to treat process wastewater from the 200-F/H Production Facilities (routine wastewater) as well as intermittent flows from the F/H Retention Basins and F/H Cooling Water Basins (nonroutine wastewater). Since start-up of the ETF at SRS in 1988, the treatment process has experienced difficulties processing routine and nonroutine wastewater. Studies have identified high bacteria and bacterial decomposition products in the wastewater as the cause for excessive fouling of the filtration system. In order to meet Waste Management requirements for the treatment of processed wastewater, an upgrade of the ETF filtration system is being developed. This upgrade must be able to process the nonroutine wastewater at design capacity. As a result, a study of alternative filter technologies was conducted utilizing simulated wastewater. The simulated wastewater tests have been completed. Three filter technologies, centrifugal polymeric ultrafilters, tubular polymeric ultrafilters, and backwashable cartridge filters have been selected for further evaluation utilizing actual ETF wastewater.

  19. F/H effluent treatment facility filtration upgrade alternative evaluations overview

    International Nuclear Information System (INIS)

    Miles, W.C. Jr.; Poirier, M.R.; Brown, D.F.

    1992-01-01

    The F/H Effluent Treatment Facility (ETF) at the Savannah River Site (SRS) was designed to treat process wastewater from the 200-F/H Production Facilities (routine wastewater) as well as intermittent flows from the F/H Retention Basins and F/H Cooling Water Basins (nonroutine wastewater). Since start-up of the ETF at SRS in 1988, the treatment process has experienced difficulties processing routine and nonroutine wastewater. Studies have identified high bacteria and bacterial decomposition products in the wastewater as the cause for excessive fouling of the filtration system. In order to meet Waste Management requirements for the treatment of processed wastewater, an upgrade of the ETF filtration system is being developed. This upgrade must be able to process the nonroutine wastewater at design capacity. As a result, a study of alternative filter technologies was conducted utilizing simulated wastewater. The simulated wastewater tests have been completed. Three filter technologies, centrifugal polymeric ultrafilters, tubular polymeric ultrafilters, and backwashable cartridge filters have been selected for further evaluation utilizing actual ETF wastewater. (author)

  20. A rapid high-performance liquid-chromatographic method for simultaneously determining the concentrations of TFM and Bayer 73 in water during lampricide treatments

    Science.gov (United States)

    Dawson, V.K.

    1982-01-01

    The high-performance liquid-chromatography (HPLC) procedure requires only minutes per sample, is specific, and is relatively sensitive (limit of detection 18 disposable cartridge. The cartridge adsorbs and retains both the lampricides and the internal standard. The quantitative elution of the three chemicals from the cartridge with a small volume of methanol effectively concentrates the sample and provides sample cleanup. The methanol extract is then analyzed directly by HPLC on an MCH 10 reverse phase column by using a methanol:0.01 mol/L acetate buffer (87:13, v:v) as the mobile phase at 2 mL/min and detected by ultraviolet spectrophotometry at 330 (or 254) nm. A microprocessor data system further facilitates the procedure by quantifying off-scale peaks and yielding results directly in units of concentration (mg/L).

  1. Penetrating chest trauma caused by a blank cartridge actuated rubber ball projectile: case presentation and ballistic investigation of an uncommon weapon type.

    Science.gov (United States)

    Frank, Matthias; Peters, Dieter; Klemm, Wolfram; Grossjohann, Rico; Ekkernkamp, Axel; Bockholdt, Britta; Seifert, Julia

    2017-09-01

    Recently, an increasing number of an uncommon weapon type based on a caliber 6-mm Flobert blank cartridge actuated revolver which discharges 10-mm-diameter rubber ball projectiles has been confiscated by police authorities following criminal offenses. A recent trauma case presenting with a penetrating chest injury occasioned an investigation into the basic ballistic parameters of this type of weapon. Kinetic energy E of the test projectiles was calculated between 5.8 and 12.5 J. Energy density ED of the test projectiles was close to or higher than the threshold energy density of human skin. It can be concluded that penetrating skin injuries due to free-flying rubber ball projectiles discharged at close range cannot be ruled out. However, in case of a contact shot, the main injury potential of this weapon type must be attributed to the high energy density of the muzzle gas jet which may, similar to well-known gas or alarm weapons, cause life-threatening or even lethal injuries.

  2. Hydrometallurgical treatment of plutonium. Bearing salt baths waste

    International Nuclear Information System (INIS)

    Bros, P.; Gozlan, J.P.; Lecomte, M.; Bourges, J.

    1993-01-01

    The salt flux issuing from the electrorefining of plutonium metal alloy in salt baths (KCI + NaCI) poses a difficult problem of the back-end alpha waste management. An alternative to the salt process promoted by Los Alamos Laboratory is to develop a hydrometallurgical treatment. A new process based on the electrochemistry technique in aqueous solution has been defined and tested successfully in the CEA. The diagram of the process exhibits two principal steps: in the head-end, a dissolution in HNO 3 medium accompanied with an electrolytic dechlorination leading to a quantitative elimination of chloride as CI 2 gas followed by its trapping one soda lime cartridge, a complete oxidative dissolution of the refractory Pu residues by electrogenerated Ag(II), in the back-end: the Pu and Am recoveries by chromatographic extractions. (authors). 10 figs., 9 refs

  3. {sup 14}CO{sub 2} processing using an improved and robust molecular sieve cartridge

    Energy Technology Data Exchange (ETDEWEB)

    Wotte, Anja, E-mail: Anja.Wotte@uni-koeln.de [Institute of Geology and Mineralogy, University of Cologne, Cologne (Germany); Wordell-Dietrich, Patrick [Thünen Institute of Climate-Smart Agriculture, Braunschweig (Germany); Wacker, Lukas [Ion Beam Physics, ETH Zurich, Zurich (Switzerland); Don, Axel [Thünen Institute of Climate-Smart Agriculture, Braunschweig (Germany); Rethemeyer, Janet [Institute of Geology and Mineralogy, University of Cologne, Cologne (Germany)

    2017-06-01

    Radiocarbon ({sup 14}C) analysis on CO{sub 2} can provide valuable information on the carbon cycle as different carbon pools differ in their {sup 14}C signature. While fresh, biogenic carbon shows atmospheric {sup 14}C concentrations, fossil carbon is {sup 14}C free. As shown in previous studies, CO{sub 2} can be collected for {sup 14}C analysis using molecular sieve cartridges (MSC). These devices have previously been made of plastic and glass, which can easily be damaged during transport. We thus constructed a robust MSC suitable for field application under tough conditions or in remote areas, which is entirely made of stainless steel. The new MSC should also be tight over several months to allow long sampling campaigns and transport times, which was proven by a one year storage test. The reliability of the {sup 14}CO{sub 2} results obtained with the MSC was evaluated by detailed tests of different procedures to clean the molecular sieve (zeolite type 13X) and for the adsorption and desorption of CO{sub 2} from the zeolite using a vacuum rig. We show that the {sup 14}CO{sub 2} results are not affected by any contamination of modern or fossil origin, cross contamination from previous samples, and by carbon isotopic fractionation. In addition, we evaluated the direct CO{sub 2} transfer from the MSC into the automatic graphitization equipment AGE with the subsequent {sup 14}C AMS analysis as graphite. This semi-automatic approach can be fully automated in the future, which would allow a high sample throughput. We obtained very promising, low blank values between 0.0018 and 0.0028 F{sup 14}C (equivalent to 50,800 and 47,200 yrs BP), which are within the analytical background and lower than results obtained in previous studies.

  4. Effects of Acute Ozone Exposure and Methyl Jasmonate Treatment on White Pine Monoterpene and Sesquiterpene Emission Rates

    Science.gov (United States)

    Faiola, C. L.; Wagner, D.; Allwine, E.; Harley, P. C.; Vanreken, T. M.

    2010-12-01

    Biogenic volatile organic compounds (BVOCs) are produced by plants and include monoterpenes, sesquiterpenes, and their oxygenated derivatives. These BVOCs are one of the principal factors influencing the oxidative capacity of the atmosphere in forested regions, and impact both ozone concentration and secondary organic aerosol formation. Under unstressed conditions, the release of BVOCs to the atmosphere is primarily controlled by the vapor pressure of the relevant compounds within the plant tissue, which is in turn dependent on temperature as well as complex biochemical production processes. However, various natural and anthropogenic stressors can alter both the quantity and composition of the BVOCs emitted by plants. Many potential stressors are expected to become stronger as climate change effects escalate. The impacts of most stressors on BVOC emissions have not been well characterized, particularly in a field setting where changes in BVOC emissions could have influential feedbacks with climate. This study investigated the effects of two stressors on monoterpene and sesquiterpene emission rates at a field site in northern Michigan: acute ozone exposure and treatment with methyl jasmonate, an herbivory proxy. The study included six repetitions of the same experiment, each time using a new set of sub-canopy eastern white pine specimens. For each experiment, dynamic branch enclosures were simultaneously used on three specimens for sample collection: one ozone treatment tree, one methyl jasmonate treatment tree, and one control tree. Sampling lines were placed in each enclosure and VOCs were collected onto cartridges packed with Tenax GR adsorbent. Samples were collected several times per day for at least two days before treatment and for five days after treatment. Cartridges were analyzed via thermodesorption with an Agilent GC/MS/FID. This analysis allowed the identification and quantification of several monoterpene and sesquiterpene species in the samples

  5. SERS as an analytical tool in environmental science: The detection of sulfamethoxazole in the nanomolar range by applying a microfluidic cartridge setup.

    Science.gov (United States)

    Patze, Sophie; Huebner, Uwe; Liebold, Falk; Weber, Karina; Cialla-May, Dana; Popp, Juergen

    2017-01-01

    Sulfamethoxazole (SMX) is a commonly applied antibiotic for treating urinary tract infections; however, allergic reactions and skin eczema are known side effects that are observed for all sulfonamides. Today, this molecule is present in drinking and surface water sources. The allowed concentration in tap water is 2·10 -7  mol L -1 . SMX could unintentionally be ingested by healthy people when drinking contaminated tap water, representing unnecessary drug intake. To assess the quality of tap water, fast, specific and sensitive detection methods are required, in which consequence measures for improving the purification of water might be initiated in the short term. Herein, the quantitative detection of SMX down to environmentally and physiologically relevant concentrations in the nanomolar range by employing surface-enhanced Raman spectroscopy (SERS) and a microfluidic cartridge system is presented. By applying surface-water samples as matrices, the detection of SMX down to 2.2·10 -9  mol L -1 is achieved, which illustrates the great potential of our proposed method in environmental science. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Polyvinylpolypyrrolidone-Supported Boron Trifluoride; Highly Efficient Catalyst for the Synthesis of N-tert-Butyl Amides

    Directory of Open Access Journals (Sweden)

    Masoud Mokhtary

    2012-01-01

    Full Text Available Highly efficient method for the preparation of N-tert-butyl amides by reaction of nitriles with tert-butyl acetate is described using polyvinylpolypyrrolidone-supported boron trifluoride (PVPP-BF3 at 70°C in good to excellent yields. Selective amidation of benzonitrile in the presence of acetonitrile was also achieved. polyvinylpolypyrrolidone-boron trifluoride complex shows non-corrosive and stable solid catalyst elevated Lewis acid property.

  7. Waste treatment by selective mineral ion exchanger

    International Nuclear Information System (INIS)

    Polito, Aurelie

    2007-01-01

    STMI, subsidiary company of the AREVA Group with over 40 years in the D and D business, has been continuously innovating and developing new decontamination techniques, with the objectives of achieving more efficient decontaminations on a growing spectrum of media. In the field of liquid waste treatment, STMI manufactures uses and commercialises selective inorganic ion exchangers (RAN). These are hydrated synthetic inorganic compounds prepared from very pure raw materials. Different types of RANs (POLYAN, OXTAIN, Fe-Cu, Fe-CoK, Si-Fe-CoK) can be used to trap a large number of radioactive elements in contaminated effluents. Different implementations could be applied depending on technical conditions. STMI's offers consist in building global solution and preliminary design of installation either in dispersed form (batch) or in column (cartridge filtration). Those products are used all over the world not only in the nuclear business (Canada, US, Belgium, France...) but also in other fields. Indeed, it provides competitive solutions to many domains of application especially water pollution control, liquid waste treatment in the nuclear business by decreasing the activity level of waste. The following paper will focus on the theoretical principle of the mineral exchanger, its implementation and the feed back collected by STMI. (author)

  8. Lyophilization Cycle Design for Dual Chamber Cartridges and a Method for Online Process Control: The "DCC LyoMate" Procedure.

    Science.gov (United States)

    Korpus, Christoph; Friess, Wolfgang

    2017-08-01

    Freeze-drying process design is a challenging task that necessitates a profound understanding of the complex interrelation among critical process parameters (e.g., shelf temperature and chamber pressure), heat transfer characteristics of the involved materials (e.g., product containers and holder devices), and critical quality attributes of the product (e.g., collapse temperatures). The Dual Chamber Cartridge "(DCC) LyoMate" (from lyophilization and automated) is a manometric temperature measurement-based process control strategy that was developed within this study to streamline this complicated task. It was successfully applied using 5% sucrose formulations with 0.5 and 1 mL fill volumes. The system was further challenged using 2, 20, and 100 mg/mL monoclonal antibody formulations. The DCC LyoMate method did not only produce pharmaceutically acceptable cakes but was also able to maintain the desired product temperature irrespective of formulation and protein content. It enabled successful process design even at high protein concentrations and aided the design and online control of the lyophilization process for drying in DCCs within a single development run. Thus, it helps to reduce development cost and the DCC LyoMate can also be easily installed on every freeze-dryer capable of performing a manometric temperature measurement, without the need for hardware modification. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  9. A comparison of surface topography characterization technologies for use in comparing spent bullet and cartridge case signatures

    Energy Technology Data Exchange (ETDEWEB)

    Batishko, C.R.; Hickman, B.J.; Cuta, F.M.

    1992-11-01

    The Pacific Northwest Laboratory was tasked by the US Department of Energy to provide technical assistance to the Federal Bureau of Investigation in evaluating and ranking technologies potentially useful in high-speed comparison of unique spent bullet and cartridge case surface signatures. Information sources included vendor input, current relevant literature, vendor phone contacts, other FBI resources, relevant PNL reports, and personal contact with numerous PNL technical staff. A comprehensive list of technologies was reduced to a list of 38 by grouping very similar methodologies, and further reduced to a short list of six by applying a set of five minimum functional requirements. A total of 14 primary criteria, many having secondary criteria, were subsequently used to evaluate each technology. The ranked short list results are reported and supported in this document, and their scores normalized to a hypothetical ideal system are as follows: (1) confocal microscopy 82.13; (2) laser dynamic focusing 72.04; (3)moire interferometry V70.94; (4)fringe field capacitance;(5)laser triangulation 66.18; (6)structured/sectioned light 65.55. Information available within the time/budget constraints which was used for the evaluation and ranking was not sufficiently detailed to evaluate specific implementations of the technologies. Each of the technologies in the short list was judged potentially capable of meeting the minimum requirements. Clever, novel engineering solutions resulting in a more cost-effective system, or a closer fit to the ``ideal system,`` could result in a reordering of the short list when actual technical proposals are evaluated. Therefore, it is recommended that a Request for Proposal not be limited to only the highest ranked technology, but include all six technologies in the short list.

  10. Assessment of 'on-treatment platelet reactivity' and relationship with cerebral micro-embolic signals in asymptomatic and symptomatic carotid stenosis.

    Science.gov (United States)

    Kinsella, Justin A; Oliver Tobin, W; Tierney, Sean; Feeley, Timothy M; Egan, Bridget; Coughlan, Tara; Ronan Collins, D; O'Neill, Desmond; Harbison, Joseph A; Doherty, Colin P; Madhavan, Prakash; Moore, Dermot J; O'Neill, Sean M; Colgan, Mary-Paula; Saqqur, Maher; Murphy, Raymond P; Moran, Niamh; Hamilton, George; McCabe, Dominick J H

    2017-05-15

    The relationship between on-treatment platelet reactivity and cerebral micro-embolic signals (MES) is unknown, and has not been previously simultaneously assessed in asymptomatic and symptomatic carotid stenosis patients. Consecutive eligible patients with ≥50% asymptomatic or recently symptomatic carotid stenosis (≤4weeks following TIA/ischaemic stroke) were recruited to this pilot study. Symptomatic patients were followed up to the 'late' phase (≥3months) following symptom onset or carotid intervention; longitudinal data were analysed from symptomatic patients with data available at both time-points. Platelet function/reactivity was assessed with the PFA-100® to measure collagen-ADP (C-ADP) and collagen-epinephrine (C-EPI) closure times in citrate-anticoagulated whole blood. Bilateral simultaneous 1-hour transcranial Doppler ultrasound (TCD) monitoring of the middle cerebral arteries was performed to classify patients as MES +ve or MES -ve. 31 patients with ≥50% asymptomatic and 46 with early symptomatic carotid stenosis or occlusion were included. 35 symptomatic patients were followed up to the late phase (23 following carotid intervention). Prevalence of 'high on-treatment platelet reactivity' (HTPR) on the C-EPI cartridge did not differ between asymptomatic and symptomatic patients overall, but was lower in 'symptomatic post-intervention' than asymptomatic patients on aspirin monotherapy (10% vs. 50%; p=0.03). The prevalence of HTPR on the C-EPI cartridge decreased between the early and late phases in symptomatic patients (63% vs. 34%; p=0.017), including those on aspirin monotherapy (p=0.016). There were no significant differences in HTPR status between asymptomatic vs. early or late symptomatic MES +ve or MES -ve patients. Carotid interventional treatment, presumably in combination with resolution of the acute phase response, may decrease the prevalence of HTPR in patients with recently symptomatic carotid stenosis over time. Preliminary subgroup

  11. A comparison of surface topography characterization technologies for use in comparing spent bullet and cartridge case signatures

    Energy Technology Data Exchange (ETDEWEB)

    Batishko, C.R.; Hickman, B.J.; Cuta, F.M.

    1992-11-01

    The Pacific Northwest Laboratory was tasked by the US Department of Energy to provide technical assistance to the Federal Bureau of Investigation in evaluating and ranking technologies potentially useful in high-speed comparison of unique spent bullet and cartridge case surface signatures. Information sources included vendor input, current relevant literature, vendor phone contacts, other FBI resources, relevant PNL reports, and personal contact with numerous PNL technical staff. A comprehensive list of technologies was reduced to a list of 38 by grouping very similar methodologies, and further reduced to a short list of six by applying a set of five minimum functional requirements. A total of 14 primary criteria, many having secondary criteria, were subsequently used to evaluate each technology. The ranked short list results are reported and supported in this document, and their scores normalized to a hypothetical ideal system are as follows: (1) confocal microscopy 82.13; (2) laser dynamic focusing 72.04; (3)moire interferometry V70.94; (4)fringe field capacitance;(5)laser triangulation 66.18; (6)structured/sectioned light 65.55. Information available within the time/budget constraints which was used for the evaluation and ranking was not sufficiently detailed to evaluate specific implementations of the technologies. Each of the technologies in the short list was judged potentially capable of meeting the minimum requirements. Clever, novel engineering solutions resulting in a more cost-effective system, or a closer fit to the ideal system,'' could result in a reordering of the short list when actual technical proposals are evaluated. Therefore, it is recommended that a Request for Proposal not be limited to only the highest ranked technology, but include all six technologies in the short list.

  12. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  13. Proteoglycan from salmon nasal cartridge promotes in vitro wound healing of fibroblast monolayers via the CD44 receptor

    International Nuclear Information System (INIS)

    Ito, Gen; Kobayashi, Takeshi; Takeda, Yoshie; Sokabe, Masahiro

    2015-01-01

    Highlights: • Proteoglycan from salmon nasal cartridge (SNC-PG) promoted wound healing in fibroblast monolayers. • SNC-PG stimulated both cell proliferation and cell migration. • Interaction between chondroitin sulfate-units and CD44 is responsible for the effect. - Abstract: Proteoglycans (PGs) are involved in various cellular functions including cell growth, adhesion, and differentiation; however, their physiological roles are not fully understood. In this study, we examined the effect of PG purified from salmon nasal cartilage (SNC-PG) on wound closure using tissue-cultured cell monolayers, an in vitro wound-healing assay. The results indicated that SNC-PG significantly promoted wound closure in NIH/3T3 cell monolayers by stimulating both cell proliferation and cell migration. SNC-PG was effective in concentrations from 0.1 to 10 μg/ml, but showed much less effect at higher concentrations (100–1000 μg/ml). The effect of SNC-PG was abolished by chondroitinase ABC, indicating that chondroitin sulfates (CSs), a major component of glycosaminoglycans (GAGs) in SNC-PG, are crucial for the SNC-PG effect. Furthermore, chondroitin 6-sulfate (C-6-S), a major CS of SNC-PG GAGs, could partially reproduce the SNC-PG effect and partially inhibit the binding of SNC-PG to cells, suggesting that SNC-PG exerts its effect through an interaction between the GAGs in SNC-PG and the cell surface. Neutralization by anti-CD44 antibodies or CD44 knockdown abolished SNC-PG binding to the cells and the SNC-PG effect on wound closure. These results suggest that interactions between CS-rich GAG-chains of SNC-PG and CD44 on the cell surface are responsible for the SNC-PG effect on wound closure

  14. Proteoglycan from salmon nasal cartridge promotes in vitro wound healing of fibroblast monolayers via the CD44 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Gen; Kobayashi, Takeshi; Takeda, Yoshie [Department of Physiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi 466-8550 (Japan); Sokabe, Masahiro, E-mail: msokabe@med.nagoya-u.ac.jp [Department of Physiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi 466-8550 (Japan); Mechanobiology Laboratory, Nagoya University Graduate School of Medicine, Nagoya, Aichi 466-8550 (Japan); Mechanobiology Institute Singapore, National University of Singapore, Singapore 117411 (Singapore)

    2015-01-16

    Highlights: • Proteoglycan from salmon nasal cartridge (SNC-PG) promoted wound healing in fibroblast monolayers. • SNC-PG stimulated both cell proliferation and cell migration. • Interaction between chondroitin sulfate-units and CD44 is responsible for the effect. - Abstract: Proteoglycans (PGs) are involved in various cellular functions including cell growth, adhesion, and differentiation; however, their physiological roles are not fully understood. In this study, we examined the effect of PG purified from salmon nasal cartilage (SNC-PG) on wound closure using tissue-cultured cell monolayers, an in vitro wound-healing assay. The results indicated that SNC-PG significantly promoted wound closure in NIH/3T3 cell monolayers by stimulating both cell proliferation and cell migration. SNC-PG was effective in concentrations from 0.1 to 10 μg/ml, but showed much less effect at higher concentrations (100–1000 μg/ml). The effect of SNC-PG was abolished by chondroitinase ABC, indicating that chondroitin sulfates (CSs), a major component of glycosaminoglycans (GAGs) in SNC-PG, are crucial for the SNC-PG effect. Furthermore, chondroitin 6-sulfate (C-6-S), a major CS of SNC-PG GAGs, could partially reproduce the SNC-PG effect and partially inhibit the binding of SNC-PG to cells, suggesting that SNC-PG exerts its effect through an interaction between the GAGs in SNC-PG and the cell surface. Neutralization by anti-CD44 antibodies or CD44 knockdown abolished SNC-PG binding to the cells and the SNC-PG effect on wound closure. These results suggest that interactions between CS-rich GAG-chains of SNC-PG and CD44 on the cell surface are responsible for the SNC-PG effect on wound closure.

  15. [Maintenance and monitoring of water treatment system].

    Science.gov (United States)

    Pontoriero, G; Pozzoni, P; Tentori, F; Scaravilli, P; Locatelli, F

    2005-01-01

    Water treatment systems must be submitted to maintenance, disinfections and monitoring periodically. The aim of this review is to analyze how these processes must complement each other in order to preserve the efficiency of the system and optimize the dialysis fluid quality. The correct working of the preparatory process (pre-treatment) and the final phase of depuration (reverse osmosis) of the system need a periodic preventive maintenance and the regular substitution of worn or exhausted components (i.e. the salt of softeners' brine tank, cartridge filters, activated carbon of carbon tanks) by a competent and trained staff. The membranes of reverse osmosis and the water distribution system, including dialysis machine connections, should be submitted to dis-infections at least monthly. For this purpose it is possible to use chemical and physical agents according to manufacturer' recommendations. Each dialysis unit should predispose a monitoring program designed to check the effectiveness of technical working, maintenance and disinfections and the achievement of chemical and microbiological standards taken as a reference. Generally, the correct composition of purified water is monitored by continuous measuring of conductivity, controlling bacteriological cultures and endotoxin levels (monthly) and checking water contaminants (every 6-12 months). During pre-treatment, water hardness (after softeners) and total chlorine (after chlorine tank) should be checked periodically. Recently the Italian Society of Nephrology has developed clinical guidelines for water and dialysis solutions aimed at suggesting rational procedures for production and monitoring of dialysis fluids. It is hopeful that the application of these guidelines will lead to a positive cultural change and to an improvement in dialysis fluid quality.

  16. Obtenção de nova fonte de peroxidase de folha de Copaifera langsdorffii Desf. com alta atividade Obtention of a new source of peroxidase from Copaifera langsdorffii leaf, Desf. with high activity

    Directory of Open Access Journals (Sweden)

    Hermelinda Penha Freire Maciel

    2006-12-01

    Full Text Available Objetivou-se neste trabalho extrair peroxidase de folha de Copaifera langsdorffii (COP, medir sua atividade, compará-la com a peroxidase de raiz forte (Horseradish peroxidase - HRP e determinar o pH ótimo, a melhor solução extratora e o efeito de aditivos sobre a atividade da COP. Os resultados mostraram que a COP atingiu 81,6% da atividade de HRP e a faixa de pH ótimo foi de 5,5 a 6,0. A melhor solução extratora da enzima foi o tampão fosfato de sódio 50 mM, pH 6,0 e o melhor aditivo foi o PVPP. Concluindo, a COP apresenta atividade mais alta que outras peroxidases de diferentes fontes citadas na literatura.The purpose of this work was to extract peroxidase from Copaifera langsdorffii leaves (COP, measure its activity, compare it to that of Horseradish peroxidase and determine the optimum pH, the best extraction solution and the effect of additives on the COP activity. The results showed that COP has 81.6% of the activity of HRP and an optimum pH range between 5.5-6.0. The best extraction solution was a sodium phosphate buffer 50 mM, pH 6.0 and the best additive was PVPP. In conclusion, COP presents higher activity than peroxidases from different sources reported in the literature.

  17. Waste water treatment plants as sources of polyfluorinated compounds, polybrominated diphenyl ethers and musk fragrances to ambient air

    International Nuclear Information System (INIS)

    Weinberg, Ingo; Dreyer, Annekatrin; Ebinghaus, Ralf

    2011-01-01

    To investigate waste water treatment plants (WWTPs) as sources of polyfluorinated compounds (PFCs), polybrominated diphenyl ethers (PBDEs) and synthetic musk fragrances to the atmosphere, air samples were simultaneously taken at two WWTPs and two reference sites using high volume samplers. Contaminants were accumulated on glass fiber filters and PUF/XAD-2/PUF cartridges, extracted compound-dependent by MTBE/acetone, methanol, or hexane/acetone and detected by GC-MS or HPLC-MS/MS. Total (gas + particle phase) concentrations ranged from 97 to 1004 pg m -3 (neutral PFCs), -3 (ionic PFCs), 5781 to 482,163 pg m -3 (musk fragrances) and -3 (PBDEs) and were usually higher at WWTPs than at corresponding reference sites, revealing that WWTPs can be regarded as sources of musk fragrances, PFCs and probably PBDEs to the atmosphere. Different concentrations at the two WWTPs indicated an influence of WWTP size or waste water origin on emitted contaminant amounts. - Waste water treatment plants can be regarded as sources of musk fragrances, polyfluorinated compounds (PFCs) and polybrominated diphenyl ethers (PBDEs) to the atmosphere

  18. The status and development of treatment techniques of typical waste electrical and electronic equipment in China: a review.

    Science.gov (United States)

    He, Yunxia; Xu, Zhenming

    2014-04-01

    A large quantity of waste electrical and electronic equipment (WEEE) is being generated because technical innovation promotes the unceasing renewal of products. China's household appliances and electronic products have entered the peak of obsolescence. Due to lack of technology and equipment, recycling of WEEE is causing serious environment pollution. In order to achieve the harmless disposal and resource utilization of WEEE, researchers have performed large quantities of work, and some demonstration projects have been built recently. In this paper, the treatment techniques of typical WEEE components, including printed circuit boards, refrigerator cabinets, toner cartridges, cathode ray tubes, liquid crystal display panels, batteries (Ni-Cd and Li-ion), hard disk drives, and wires are reviewed. An integrated recycling system with environmentally friendly and highly efficient techniques for processing WEEE is proposed. The orientation of further development for WEEE recycling is also proposed.

  19. Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis.

    Science.gov (United States)

    Chen, Apeng; Lu, Joann J; Gu, Congying; Zhang, Min; Lynch, Kyle B; Liu, Shaorong

    2015-08-05

    Toward developing a micro HPLC cartridge, we have recently built a high-pressure electroosmotic pump (EOP). However, we do not recommend people to use this pump to deliver an organic solvent directly, because it often makes the pump rate unstable. We have experimented several approaches to address this issue, but none of them are satisfactory. Here, we develop an innovative approach to address this issue. We first create an abruption (a dead-volume) within a fluid conduit. We then utilize an EOP to withdraw, via a selection valve, a train of eluent solutions having decreasing eluting power into the fluid conduit. When these solutions are further aspirated through the dead-volume, these solutions are partially mixed, smoothening concentration transitions between two adjacent eluent solutions. As these solutions are pushed back, through the dead-volume again, a smooth gradient profile is formed. In this work, we characterize this scheme for gradient formation, and we incorporate this approach with a high-pressure EOP, a nanoliter injection valve, and a capillary column, yielding a micro HPLC system. We then couple this micro HPLC with an electrospray ionization - mass spectrometer for peptide and protein separations and identifications. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Clinical evaluation of high-risk HPV detection on self-samples using the indicating FTA-elute solid-carrier cartridge.

    Science.gov (United States)

    Geraets, D T; van Baars, R; Alonso, I; Ordi, J; Torné, A; Melchers, W J G; Meijer, C J L M; Quint, W G V

    2013-06-01

    High-risk human papillomavirus (hrHPV) testing in cervical screening is usually performed on physician-taken cervical smears in liquid-based medium. However, solid-state specimen carriers allow easy, non-hazardous storage and transportation and might be suitable for self-collection by non-responders in screening and in low-resource settings. We evaluated the adequacy of self-collected cervicovaginal (c/v) samples using a Viba-brush stored on an Indicating FTA-elute cartridge (FTA-based self-sampling) for hrHPV testing in women referred to a gynecology clinic due to an abnormal smear. 182 women accepted to self-collect a c/v sample. After self-sampling, a physician obtained a conventional liquid-based cervical smear. Finally, women were examined by colposcopy and a biopsy was taken when clinically indicated. Self-samples required only simple DNA elution, and DNA was extracted from physician-obtained samples. Both samples were tested for 14 hrHPVs by GP5+/6+-EIA-LQ Test and SPF(10)-DEIA-LiPA(25). Both assays detected significantly more hrHPV in physician-collected specimens than in self-collected samples (75.3% and 67.6% by SPF(10); 63.3% and 53.3% by GP5+/6+, respectively). The combination of physician-collected specimen and GP5+/6+ testing demonstrated the optimal balance in sensitivity (98.0%) and specificity (48.1%) for CIN2+ detection in this referral population. A test system of FTA-based self-collection and SPF(10) hrHPV detection approached this sensitivity (95.9%) and specificity (42.9%). These results show that the clinical performance of hrHPV detection is determined by both the sample collection system and the test method. FTA-based self-collection with SPF(10) testing might be valuable when a liquid-based medium cannot be used, but requires further investigation in screening populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Polymeric hollow fiber membranes for bioartificial organs and tissue engineering applications

    NARCIS (Netherlands)

    Diban-Ibrahim Gomez, Nazely; Stamatialis, Dimitrios

    2014-01-01

    Polymeric hollow fiber (HF) membranes are commercially available, i.e. microfiltration and ultrafiltration cartridges or reverse osmosis and gas separation modules, to be applied for separation purposes in industry, for instance to recover valuable raw materials or products, or for the treatment of

  2. Breast Tumor Detection and Treatment Using Tarvacin Labeled with Arsenic Radionuclides

    Science.gov (United States)

    2007-04-01

    have also purchased and tested isotopically enriched 76GeO2. Materials and Methods. All reagents and solvents were purchased from Sigma-Aldrich...and dimethylsulfoxide were purchased from Pierce (Rockford, IL). BOND ELUT ENV cartridges with a sorbent mass of 25 mg were purchased from Varian...two days prior to the above target processing. Briefly, 2.0 mg of SATA (N-Succinimidyl S- Acetylthioacetate) was dissolved in 500 μL of DMSO , giving a

  3. Evaluating the Impact of Ambient Benzene Vapor Concentrations on Product Water of Condensation Water from Air Technology

    Science.gov (United States)

    2016-03-07

    by a sediment filter; or a combination of 8 water treatment technologies. Water treatment type is chosen by the manufacture and is diverse...the water treatment module was comprised of a sediment , charcoal and ultra-fine membrane and Halo Pure cartridge. Other components such as the... water was calculated. This study used the EPA site assessment calculator for the Office of Solid Waste and Emergency Response (OSWER) Method to

  4. Bottom loaded filter for radioactive liquids

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1980-01-01

    A bottom loaded filter assembly for filtering radioactive liquids through a replaceable cartridge filter is disclosed. The filter assembly includes a lead-filled jacket enveloping a housing having a chamber therein for the filter cartridge. A track arrangement carries a hatch for sealing the chamber. A spacer plug supports the cartridge within guide means associated with the inlet conduit in the chamber. The plug and cartridge drop out of the chamber when the hatch is unbolted and move laterally of the chamber. During cartridge replacement, a new plug and cartridge are supported in the guide means by a spacer bar inserted across the track means under the chamber. The hatch is then slid under the chamber and bolted to the vessel, engaging an o-ring to seal the chamber

  5. Stable isotopic carbon composition of apples and their subfractions--juice, seeds, sugars, and nonvolatile acids.

    Science.gov (United States)

    Lee, H S; Wrolstad, R E

    1988-01-01

    The 13C:12C ratios of 8 authentic apple juice samples and their subfractions were determined by mass spectrometry. Apples from Argentina, Mexico, New Zealand, and the United States were processed into juice; pulp was collected from the milled fruit and seeds were collected from the press-cake. Sugars, nonvolatile acids, and phenolics were isolated from the juice by treatment with ion-exchange resins and polyvinylpyrrolidone (PVPP). The mean value for all juice samples was -24.2% which is close to the values reported by other investigators. Juice from apples grown in Argentina, Mexico, and New Zealand did not differ from U.S. samples. The isotopic composition of the subfractions ranged from -22.0 to -31.0%. The values for the pulp were essentially the same as for juice. The sugar fraction was slightly less negative than the juice; the nonvolatile acid and phenolic fractions were more negative. The levels of nonvolatile acids and phenolics in apple juice are low, however, so these compounds contribute little to overall delta 13C values in juice.

  6. Bottom loaded filter for radioactive liquid

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1980-01-01

    A specification is given for a bottom loaded filter assembly for filtering radioactive liquids through a replaceable cartridge filter, which includes a lead-filled jacket enveloping a housing having a chamber therein for the filter cartridge. A track arrangement carries a hatch for sealing the chamber. A spacer plug supports the cartridge within guide means associated with the inlet conduit in the chamber. The plug and cartridge drop out of the chamber when the hatch is unbolted and moved laterally of the chamber along the track. During cartridge replacement a new plug and cartridge are supported in the guide means by a spacer bar inserted across the track means under the chamber. The hatch is then slid under the chamber and bolted to a flange on the housing, engaging an O-ring to seal the chamber. (author)

  7. Adjustments Recommended in Fiscal Year 1982 Ammunition Procurement and Modernization Programs

    Science.gov (United States)

    1981-06-30

    No comment 4.8 No comment Cartridge, 7.6 2-mm., all types Cartridge, .45 caliber ball 31.9 58.3 -0.8 2.9 Cartridge, 1.6 30-mm., TP...4.5 - 1.6 57.5 Inventory exceeds re- quirements for rifle grenade cartridge 2.8 No comment 77.1 No comment - Inventory exceeds re...quirements 10.7 Inventory exceeds re- quirements Premature buy Premature buy 4.5 No comment 38 APPENDIX I APPENDIX

  8. 76 FR 70422 - Procurement List Additions

    Science.gov (United States)

    2011-11-14

    ..., Disinfectant Cleaner-Degreaser Cartridge Concentrate. NSN: 7930-00-NIB-0593--Refills, Multi-Purpose Cleaner, Cartridge Concentrate. NSN: 7930-00-NIB-0594--Starter Kit, Multi-Purpose Cleaner, Cartridge Concentrate. NPA..., Anniston, AL Service Type/Locations: Rubbish Removal and Recycling Service Department of the Treasury...

  9. Incidence of missed inferior alveolar nerve blocks in vital asymptomatic subjects and in patients with symptomatic irreversible pulpitis.

    Science.gov (United States)

    Fowler, Sara; Reader, Al; Beck, Mike

    2015-05-01

    The purpose of this retrospective study was to determine the incidence of missed inferior alveolar nerve (IAN) blocks by using a 1- or 2-cartridge volume of 2% lidocaine with 1:100,000 epinephrine in vital asymptomatic teeth and in emergency patients with symptomatic irreversible pulpitis. As part of 37 studies, 3169 subjects/patients were evaluated for missed IAN blocks. The study included 2450 asymptomatic subjects and 719 emergency patients presenting with symptomatic irreversible pulpitis. Each subject or patient received either a 1- or 2-cartridge volume of 2% lidocaine with 1:100,000 epinephrine. A missed block was defined as no lip numbness at 15-20 minutes after the IAN block. The effect of anesthetic volume on the incidence of missed blocks was assessed by using mixed models logistic regression with individual studies as a random effect. The incidence of missed blocks for asymptomatic subjects was 6.3% for the 1-cartridge volume and 3.8% for the 2-cartridge volume. For patients presenting with irreversible pulpitis, the incidence of missed blocks was 7.7% for the 1-cartridge volume and 2.3% for the 2-cartridge volume. In both asymptomatic subjects and patients with irreversible pulpitis, the 2-cartridge volume was significantly (P = .0395) better than the 1-cartridge volume. There were no significant effects for pulpal diagnosis (P = .7523) or the pulpal diagnosis and anesthetic volume interaction (P = .3973). Concerning missed IAN blocks, we concluded that administration of a 2-cartridge volume was significantly better (P = .0395) than a 1-cartridge volume in both asymptomatic subjects and emergency patients presenting with irreversible pulpitis. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Development of procedures for calculating stiffness and damping properties of elastomers in engineering applications. Part 4: Testing of elastomers under a rotating load. [resonance testing

    Science.gov (United States)

    Darlow, M. S.; Smalley, A. J.

    1977-01-01

    A test rig designed to measure stiffness and damping of elastomer cartridges under a rotating load excitation is described. The test rig employs rotating unbalance in a rotor which runs to 60,000 RPM as the excitation mechanism. A variable resonant mass is supported on elastomer elements and the dynamic characteristics are determined from measurements of input and output acceleration. Five different cartridges are considered: three of these are buttons cartridges having buttons located in pairs, with 120 between each pair. Two of the cartridges consist of 360 elastomer rings with rectangular cross-sections. Dynamic stiffness and damping are measured for each cartridge and compared with predictions at different frequencies and different strains.

  11. Pharmaceutical and personal care products in domestic wastewater and their removal in anaerobic treatment systems: Septic tank – up flow anaerobic filter.

    Directory of Open Access Journals (Sweden)

    Juan Pablo Arrubla Vélez

    2016-01-01

    Full Text Available In several countries around the world, Pharmaceutical and Personal Care Products (PPCPs exist in aquatic environments, a fact that increases the awareness within the scientific community with respect to their possible fate and environment effects. This research presents a preliminary monitoring of use, consumption and presence of PPCPs in wastewater from a treatment plant in a rural area of Pereira (Colombia. Domestic sewage is treated in a septic tank followed by an Up-Flow Anaerobic Filter and its effluent is discharged into the Otún River, upstream of the water intake of the supply system of the city. The compounds monitored in this research included ibuprofen, naproxen, diclofenac, aspirin, ketoprofen, caffeine, galaxolide, tonalide and dihydrojasmonate. An adapted method of multi-residue analysis was used, which is based on solid phase extraction with hydrophilic-lipophilic balance cartridges, and determination by gas chromatography-mass spectrometry. The removal efficiencies demonstrated that the treatment plant could eliminate less than 50% of dihydrojasmonate, diclofenac and galaxolide existing in wastewater; concentration of aspirin, naproxen and tonalide could only be reduced in 15%; and caffeine, ibuprofen and ketoprofen were not removed. Results provided basic information to decide over the necessity of complementary treatments for effluents from systems with the mentioned units.

  12. Biochemical analysis of cerebrospinal fluid in the laboratories of deployed medical treatment facilities: are Multistix 10 SG strip and iSTAT useful?

    Science.gov (United States)

    Lefrere, Bertrand; Plantamura, J; Renard, C; Ceppa, F; Delacour, H

    2017-12-01

    During military deployment, the diagnosis and the management of acute bacterial meningitis can be problematic, as deployed Medical Treatment Facilities (MTFs) often have a limited laboratory diagnostic capability. However, French Role 2 and 3 MTFs have point-of-care (POC) testing to perform urinary (Multistix 10 SG strip) and blood (iSTAT handheld analyser) biochemical testing mentioned in AMedP8.5. The purpose of this study was to compare the accuracy of this urine test strip and of the iSTAT CHEM8 and CG4 cartridges with a standard hospital bench top analyser in order to determine if these POC devices have a potential role in the biochemical analysis of cerebrospinal fluid (CSF protein, CSF glucose and CSF lactate, respectively). Agreement between the index methods and the reference methods (suitable kits on the Cobas 6 000 System) was evaluated by parallel testing of 30 CSF samples by both techniques. For CSF protein, agreement between the strip and the reference method was evaluated determining the κ coefficient. For CSF glucose and CSF lactate subgroups, least squares linear regressions were calculated and Bland-Altman analyses were performed. The Multistix 10 SG strip can be used to make a semiquantitative determination of CSF protein. A good agreement between the strip and the reference method was observed (κ coefficient: 0.93 (IC 95 0.82 to 1)). This strip is thus well adapted to demonstrate an elevation of CSF protein level as observed in acute bacterial meningitis. The iSTAT CHEM8 and CG4+ cartridges correlated well with the reference methods for the determination of CSF glucose and CSF lactate, respectively (r 2 >0.98) but exhibited a negative bias (∼ -7% and ∼ -15%, respectively). The combined use of the Multistix 10 SG strip and of the iSTAT system appears to be an attractive solution for the biochemical investigation of CSF in medical treatment facilities with limited laboratory diagnostic capability. Published by the BMJ Publishing Group

  13. A Method for Multiple Mycotoxin Analysis in Wines by Solid Phase Extraction and Multifunctional Cartridge Purification, and Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry

    Science.gov (United States)

    Tamura, Masayoshi; Takahashi, Ayumi; Uyama, Atsuo; Mochizuki, Naoki

    2012-01-01

    An analytical method using two solid phase extractions and ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was developed for the identification and quantification of 14 mycotoxins (patulin, deoxynivalenol, aflatoxins B1, B2, G1, G2, M1, T-2 toxin, HT-2 toxin, zearalenone, fumonisins B1, B2, B3, and ochratoxin A) in domestic and imported wines. Mycotoxins were purified with an Oasis HLB cartridge, followed by a MultiSepTM #229 Ochra. As a result, sufficient removal of the pigments and highly polar matrices from the red wines was achieved. UHPLC conditions were optimized, and 14 mycotoxins were separated in a total of 13 min. Determinations performed using this method produced high correlation coefficients for the 14 mycotoxins (R > 0.990) and recovery rates ranging from 76 to 105% with good repeatability (relative standard deviation RSD < 12%). Twenty-seven samples of domestic and imported wines were analyzed using this method. Although ochratoxin A (OTA) and fumonisins (FMs) were detected in several samples, the FM levels were less than limits of quantification (LOQs) (1 μg/L), and even the largest of the OTA levels was below the EU regulatory level (2 μg/L). These results suggest that the health risk posed to consumers from the wines available in Japan is relatively low. PMID:22822458

  14. Evaluation of charred porous polymers as a method of storm water pollution prevention for shipyards

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G.E.

    1998-08-01

    Most shipyards have viable Best Management Practices (BMPs) in place to mitigate the transport of heavy metals to surface waters by storm water. Despite aggressive efforts to control storm water, shipyards have come under increased regulatory pressure to further reduce concentrations of heavy metals, such as copper and nickel, in storm water discharges. The tightening of regulatory requirements warrants research into additional BMPs. The objectives of this research project were to: (1) determine the feasibility of placing a replaceable cartridge of adsorbent material within a storm water collection system; and (2) evaluate two commercially available charred porous polymer adsorbents for the removal of heavy metals from storm water. The results indicated that there are commercially available storm water treatment components which could be adapted to house a cartridge of porous adsorbent material.

  15. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    Science.gov (United States)

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Multi-chamber nucleic acid amplification and detection device

    Science.gov (United States)

    Dugan, Lawrence

    2017-10-25

    A nucleic acid amplification and detection device includes an amplification cartridge with a plurality of reaction chambers for containing an amplification reagent and a visual detection reagent, and a plurality of optically transparent view ports for viewing inside the reaction chambers. The cartridge also includes a sample receiving port which is adapted to receive a fluid sample and fluidically connected to distribute the fluid sample to the reaction chamber, and in one embodiment, a plunger is carried by the cartridge for occluding fluidic communication to the reaction chambers. The device also includes a heating apparatus having a heating element which is activated by controller to generate heat when a trigger event is detected. The heating apparatus includes a cartridge-mounting section which positioned a cartridge in thermal communication with the heating element so that visual changes to the contents of the reaction chambers are viewable through the view ports.

  17. Evaluation of {sup 131}I retention in several adsorbers

    Energy Technology Data Exchange (ETDEWEB)

    Catanoso, Marcela F.; Osso Junior, Joao Alberto, E-mail: marcela.forli@gmail.co, E-mail: jaosso@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Diretoria de Radiofarmacia

    2011-07-01

    Several iodine radioisotopes are used in nuclear medicine for treatment and diagnostic purposes. The radioisotope {sup 131}I is used both in diagnosis and therapy due to its physical characteristics of decay by {beta}{sup -} and its {gamma}-ray emissions suitable for diagnosis. It is routinely produced at IPEN through the irradiation of TeO{sub 2} targets in the IEA-R1m nuclear reactor. After the irradiation, the {sup 131}I is separated by dry distillation, where the targets are put in an oven, heated at 760 deg C for 2 hours and the {sup 131}I, volatile, is carried by an O{sub 2} gas stream. The aim of this work was to evaluate the retention and elution of {sup 131}I samples produced at IPEN in several adsorbers as part of a project aiming the purification of these radioisotopes, allowing the labeling of biomolecules. Samples of {sup 131}I were used for retention and elution studies with the following adsorbers: commercial cartridges, anionic resin columns and cationic resin column. The results showed that Ag cartridges and anionic resins Dowex 1X8, Dowex 3 and IRA 400 had a great iodine retention but no elution after using specific eluents. The QMA light, acid alumina, neutral alumina and cationic resin Dowex 50WX4 showed high retention and elution and QMA plus and cationic resin Dowex 50WX8 and Dowex 50WX12 had a good retention but lower elution. Regarding to the better retention and elution, Ag cartridges and resins showed a higher percentage of iodine retention but lower elution yield and QMA light, acid and neutral alumina cartridges showed better results. (author)

  18. Evaluation of 131I retention in several adsorbers

    International Nuclear Information System (INIS)

    Catanoso, Marcela F.; Osso Junior, Joao Alberto

    2011-01-01

    Several iodine radioisotopes are used in nuclear medicine for treatment and diagnostic purposes. The radioisotope 131 I is used both in diagnosis and therapy due to its physical characteristics of decay by β - and its γ-ray emissions suitable for diagnosis. It is routinely produced at IPEN through the irradiation of TeO 2 targets in the IEA-R1m nuclear reactor. After the irradiation, the 131 I is separated by dry distillation, where the targets are put in an oven, heated at 760 deg C for 2 hours and the 131 I, volatile, is carried by an O 2 gas stream. The aim of this work was to evaluate the retention and elution of 131 I samples produced at IPEN in several adsorbers as part of a project aiming the purification of these radioisotopes, allowing the labeling of biomolecules. Samples of 131 I were used for retention and elution studies with the following adsorbers: commercial cartridges, anionic resin columns and cationic resin column. The results showed that Ag cartridges and anionic resins Dowex 1X8, Dowex 3 and IRA 400 had a great iodine retention but no elution after using specific eluents. The QMA light, acid alumina, neutral alumina and cationic resin Dowex 50WX4 showed high retention and elution and QMA plus and cationic resin Dowex 50WX8 and Dowex 50WX12 had a good retention but lower elution. Regarding to the better retention and elution, Ag cartridges and resins showed a higher percentage of iodine retention but lower elution yield and QMA light, acid and neutral alumina cartridges showed better results. (author)

  19. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  20. A neural network to improve dim-light vision? Dendritic fields of first-order interneurons in the nocturnal bee Megalopta genalis.

    Science.gov (United States)

    Greiner, Birgit; Ribi, Willi A; Warrant, Eric J

    2005-11-01

    Using the combined Golgi-electron microscopy technique, we have determined the three-dimensional dendritic fields of the short visual fibres (svf 1-3) and first-order interneurons or L-fibres (L1-4) within the first optic ganglion (lamina) of the nocturnal bee Megalopta genalis. Serial cross sections have revealed that the svf type 2 branches into one adjacent neural unit (cartridge) in layer A, the most distal of the three lamina layers A, B and C. All L-fibres, except L1-a, exhibit wide lateral branching into several neighbouring cartridges. L1-b shows a dendritic field of seven cartridges in layers A and C, dendrites of L2 target 13 cartridges in layer A, L3 branches over a total of 12 cartridges in layer A and three in layer C and L4 has the largest dendritic field size of 18 cartridges in layer C. The number of cartridges reached by the respective L-fibres is distinctly greater in the nocturnal bee than in the worker honeybee and is larger than could be estimated from our previous Golgi-light microscopy study. The extreme dorso-ventrally oriented dendritic field of L4 in M. genalis may, in addition to its potential role in spatial summation, be involved in edge detection. Thus, we have shown that the amount of lateral spreading present in the lamina provides the anatomical basis for the required spatial summation. Theoretical and future physiological work should further elucidate the roles that this lateral spreading plays to improve dim-light vision in nocturnal insects.

  1. Ochratoxin A removal from red wine by several oenological fining agents: bentonite, egg albumin, allergen-free adsorbents, chitin and chitosan.

    Science.gov (United States)

    Quintela, S; Villarán, M C; López De Armentia, I; Elejalde, E

    2012-01-01

    The ability of several oenological fining agents to remove ochratoxin A (OTA) from red wine was studied. The adsorbents tested were activated sodium bentonite, egg albumin, allergen-free adsorbents (complex PVPP, plant protein and amorphous silica (complex) and high molecular weight gelatine), and the non-toxic biodegradable polymers (chitin and chitosan). Several dosages within the oenological use range were tested and the wine pH, colour parameters and polyphenol concentration impact associated with each fining agent were studied. Generally, OTA removal achieved in all treatments was higher when the adsorbent dosage increased, but the impact on wine quality also was higher. Chitin at 50 g hl(-1) removed 18% the OTA without affecting significantly the wine-quality parameters. At the highest dosage tested the gelatine and complex treatments achieved greater OTA removal (up to 39-40%) compared with bentonite, egg albumin and chitin. Moreover, the gelatine and the complex had a lower impact on colour parameters and polyphenol concentration compared with chitosan, whilst OTA was reduced to around 40%. Chitosan achieved the greatest OTA removal (67%), but it strongly affected the wine-quality parameters. Otherwise, bentonite showed a relative efficiency to remove OTA, but the CI value decreased considerably. The egg albumin treatment only removed OTA up to 16% and moreover affected strongly the CI value and CIELab parameters. The results of this survey showed that the non-toxic chitin adsorbent and the allergen-free adsorbents tested could be considered as alternative fining agents to reduce OTA in red wine.

  2. Development and characterization of a novel plug and play liquid chromatography-mass spectrometry (LC-MS) source that automates connections between the capillary trap, column, and emitter.

    Science.gov (United States)

    Bereman, Michael S; Hsieh, Edward J; Corso, Thomas N; Van Pelt, Colleen K; Maccoss, Michael J

    2013-06-01

    We report the development and characterization of a novel, vendor-neutral ultra-high pressure-compatible (~10,000 p.s.i.) LC-MS source. This device is the first to make automated connections with user-packed capillary traps, columns, and capillary emitters. The source uses plastic rectangular inserts (referred to here as cartridges) where individual components (i.e. trap, column, or emitter) can be exchanged independent of one another in a plug and play manner. Automated robotic connections are made between the three cartridges using linear translation powered by stepper motors to axially compress each cartridge by applying a well controlled constant compression force to each commercial LC fitting. The user has the versatility to tailor the separation (e.g. the length of the column, type of stationary phase, and mode of separation) to the experimental design of interest in a cost-effective manner. The source is described in detail, and several experiments are performed to evaluate the robustness of both the system and the exchange of the individual trap and emitter cartridges. The standard deviation in the retention time of four targeted peptides from a standard digest interlaced with a soluble Caenorhabditis elegans lysate ranged between 3.1 and 5.3 s over 3 days of analyses. Exchange of the emitter cartridge was found to have an insignificant effect on the abundance of various peptides. In addition, the trap cartridge can be replaced with minimal effects on retention time (<20 s).

  3. Evaluation of the FTA carrier device for human papillomavirus testing in developing countries.

    Science.gov (United States)

    Gonzalez, Paula; Cortes, Bernal; Quint, Wim; Kreimer, Aimée R; Porras, Carolina; Rodríguez, Ana Cecilia; Jimenez, Silvia; Herrero, Rolando; Struijk, Linda; Hildesheim, Allan; Melchers, Willem

    2012-12-01

    Liquid-based methods for the collection, transportation, and storage of cervical cells are cumbersome and expensive and involve laborious DNA extraction. An FTA cartridge is a solid carrier device, easier to handle and allowing simple DNA elution for human papillomavirus (HPV) testing. HPV-DNA results from cervical specimens collected in PreservCyt medium (Hologic, Inc.) and the indicating FTA elute cartridge were compared in an area where transportation and storage may affect the performance of the test. Cervical cells from 319 young adult women enrolled in the Costa Rica Vaccine Trial were collected by a nurse using a Cervex brush (Roberts), which was placed on the FTA cartridge and subsequently rinsed in 20 ml of PreservCyt medium. Two 0.5-ml PreservCyt aliquots were frozen for HPV-PCR testing; the FTA cartridges were kept at room temperature. HPV-DNA detection and typing was performed using SPF(10) PCR/DEIA (DNA enzyme immunoassay detection of amplimers)/LiPA(25) system. The percent agreement, agreement among positives, and kappas were estimated. Positivity was higher for FTA compared to PreservCyt specimens (54.5% versus 45.8%, P FTA collection for HPV testing. HPV-DNA detection from FTA cartridges is broadly comparable to detection from PC medium. The higher HPV detection observed for FTA-collected specimens should be explored further. FTA cartridges could provide a simpler and more cost-effective method for cervical cell collection, storage, and transportation for HPV-DNA detection in research settings in developing countries.

  4. A simple and rapid in situ preconcentration method for the determination of phosphate in environmental waters by use of solid-phase extraction, and its applications to brackish lake waters.

    Science.gov (United States)

    Okumura, M; Tong, L; Fujinaga, K; Seike, Y

    2001-05-01

    A simple and rapid in situ preconcentration method for the determination of phosphate in environmental waters has been developed for field analysis. This method is based on solid-phase extraction on a zirconium-loaded Sep-Pack Accell CM cartridge (Zr-SP) and is applicable to studies in which sampling is performed by use of a graduated syringe to prevent contamination and to ensure easy operation at sampling sites. The Zr-SP cartridge was prepared by passing 0.1 mol L(-1) zirconium solution through a Sep-Pak Accell CM cartridge, packed with cation exchange sorbent based on a silica matrix. The adsorption of phosphate and its desorption depend only on the pH of the solution. A water sample containing phosphate was adjusted to pH 2 and passed through the Zr-SP cartridge to collect it. The retained phosphate was quantitatively eluted with 0.5 mol L(-1) sodium hydroxide solution. The phosphate retained in the Zr-SP cartridge was stable for at least one month. The established preconcentration method was successfully applied to brackish lake waters to investigate seasonal changes in the distribution and behavior of phosphate in a brackish lake.

  5. Simple system for isothermal DNA amplification coupled to lateral flow detection.

    Directory of Open Access Journals (Sweden)

    Kristina Roskos

    Full Text Available Infectious disease diagnosis in point-of-care settings can be greatly improved through integrated, automated nucleic acid testing devices. We have developed an early prototype for a low-cost system which executes isothermal DNA amplification coupled to nucleic acid lateral flow (NALF detection in a mesofluidic cartridge attached to a portable instrument. Fluid handling inside the cartridge is facilitated through one-way passive valves, flexible pouches, and electrolysis-driven pumps, which promotes a compact and inexpensive instrument design. The closed-system disposable prevents workspace amplicon contamination. The cartridge design is based on standard scalable manufacturing techniques such as injection molding. Nucleic acid amplification occurs in a two-layer pouch that enables efficient heat transfer. We have demonstrated as proof of principle the amplification and detection of Mycobacterium tuberculosis (M.tb genomic DNA in the cartridge, using either Loop Mediated Amplification (LAMP or the Exponential Amplification Reaction (EXPAR, both coupled to NALF detection. We envision that a refined version of this cartridge, including upstream sample preparation coupled to amplification and detection, will enable fully-automated sample-in to answer-out infectious disease diagnosis in primary care settings of low-resource countries with high disease burden.

  6. Capturing [11C]CO2 for use in aqueous applications

    International Nuclear Information System (INIS)

    Vandehey, Nicholas T.; O’Neil, James P.

    2014-01-01

    We present a simple method for trapping [ 11 C]CO 2 gas and releasing it into a buffered solution using an ion-exchange cartridge. Sodium hydroxide cartridges captured >99% of [ 11 C]CO 2 following NaOH activation. A sodium bicarbonate solution eluted >99% of trapped radioactivity. Trapping [ 11 C]CO 2 directly in small volumes of several solutions was less effective than cartridge methods. The recommended methods allow for fast and simple production of highly concentrated carbon-11 containing aqueous solutions for use in filling phantoms, calibrating detectors, or (bio)geochemical experiments. - Highlights: • An ion exchange resin can trap [ 11 C]CO 2 gas and release it with saturated bicarbonate. • Elution from cartridge requires as little as 300 µL volume, with eluant at pH=10. • SPE trap-and-release provided better results than trapping in solution

  7. Apparatus for filtering radioactive fluids

    International Nuclear Information System (INIS)

    Gischel, E.H.

    1975-01-01

    Apparatus is provided for filtering radioactive particles from the cooling and/or auxiliary process water of a nuclear reactor, or nuclear fuel processing plant, or other installations wherein radioactive fluid systems are known to exist. The apparatus affords disposal of the captured particles in a manner which minimizes the exposure of operating personnel to radioactivity. The apparatus comprises a housing adapted to contain a removable filter cartridge assembly, a valve normally closing the lower end of the housing, an upwardly-open shipping cask located below the valve, and an elongated operating rod assembly projecting upwardly from the filter cartridge assembly and through the upper end of the housing to enable a workman to dismount the filter cartridge assembly from its housing and to lower the filter cartridge assembly through the valve and into the cask from a remote location above the housing. (U.S.)

  8. 76 FR 57719 - Procurement List; Proposed Additions

    Science.gov (United States)

    2011-09-16

    ... proposed for addition to the Procurement List for production by the nonprofit agencies listed: Products NSN: 7930-00-NIB-0583--Refills, Bathroom Cleaner and Deodorizer, Cartridge Concentrate. NSN: 7930-00-NIB-0584--Starter Kit, Bathroom Cleaner and Deodorizer, Cartridge Concentrate. NSN: 7930-00-NIB-0585...

  9. 76 FR 35744 - Amendments to National Emission Standards for Hazardous Air Pollutants for Area Sources: Plating...

    Science.gov (United States)

    2011-06-20

    ... Metal Valve and Pipe Fitting Manufacturing; 332999, All Other Miscellaneous Fabricated Metal Product... spraying operation and exhaust them to a water curtain, or a cartridge, fabric, or HEPA filter... from the thermal spraying operation and exhaust them to a cartridge, fabric, or HEPA filter...

  10. 76 FR 57913 - Amendments to National Emission Standards for Hazardous Air Pollutants for Area Sources: Plating...

    Science.gov (United States)

    2011-09-19

    ... Fixture Fitting and Trim Manufacturing; Other Metal Valve and Pipe Fitting Manufacturing; 332999, All... thermal spraying operation and exhaust them to a water curtain, or a cartridge, fabric, or HEPA filter... from the thermal spraying operation and exhaust them to a cartridge, fabric, or HEPA filter...

  11. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    Science.gov (United States)

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  12. A General Constant Power Generation Algorithm for Photovoltaic Systems

    DEFF Research Database (Denmark)

    Tafti, Hossein Dehghani; Maswood, Ali Iftekhar; Konstantinou, Georgios

    2018-01-01

    Photovoltaic power plants (PVPPs) typically operate by tracking the maximum power point in order to maximize conversion efficiency. However, with the continuous increase of installed grid-connected PVPPs, power system operators have been experiencing new challenges, like overloading, overvoltages...... on a hysteresis band controller in order to obtain fast dynamic response under transients and low power oscillation during steady-state operation. The performance of the proposed algorithm for both single- and two-stage PVPPs is examined on a 50-kVA simulation setup of these topologies. Moreover, experimental...... and operation during grid voltage disturbances. Consequently, constant power generation (CPG) is imposed by grid codes. An algorithm for the calculation of the photovoltaic panel voltage reference, which generates a constant power from the PVPP, is introduced in this paper. The key novelty of the proposed...

  13. A Modern Apparatus for Performing Flash Chromatography: An Experiment for the Organic Laboratory

    Science.gov (United States)

    Naumiec, Gregory R.; Del Padre, Angela N.; Hooper, Matthew M.; Germaine, Alison St.; DeBoef, Brenton

    2013-01-01

    A modern apparatus for performing flash chromatography using commercially available, prepacked silica cartridges has been developed. The key advantage of this system, when compared to traditional flash chromatography, is its use of commercially available silica cartridges, which obviates the need for students to handle silica gel. The apparatus…

  14. Proteomic analysis of polypeptides captured from blood during extracorporeal albumin dialysis in patients with cholestasis and resistant pruritus.

    Directory of Open Access Journals (Sweden)

    Marina Gay

    Full Text Available Albumin dialysis using the molecular adsorbent recirculating system (MARS is a new therapeutic approach for liver diseases. To gain insight into the mechanisms involved in albumin dialysis, we analyzed the peptides and proteins absorbed into the MARS strong anion exchange (SAX cartridges as a result of the treatment of patients with cholestasis and resistant pruritus. Proteins extracted from the SAX MARS cartridges after patient treatment were digested with two enzymes. The resulting peptides were analyzed by multidimensional liquid chromatography coupled to tandem mass spectrometry. We identified over 1,500 peptide sequences corresponding to 144 proteins. In addition to the proteins that are present in control albumin-derived samples, this collection includes 60 proteins that were specific to samples obtained after patient treatment. Five of these proteins (neutrophil defensin 1 [HNP-1], secreted Ly-6/uPAR-related protein 1 [SLURP1], serum amyloid A, fibrinogen alpha chain and pancreatic prohormone were confirmed to be removed by the dialysis procedure using targeted selected-reaction monitoring MS/MS. Furthermore, capture of HNP-1 and SLURP1 was also validated by Western blot. Interestingly, further analyses of SLURP1 in serum indicated that this protein was 3-fold higher in cholestatic patients than in controls. Proteins captured by MARS share certain structural and biological characteristics, and some of them have important biological functions. Therefore, their removal could be related either to therapeutic or possible adverse effects associated with albumin dialysis.

  15. Use of self cleaning filters as pre-filter in water injection for maintenance of fine filters life; Uso de filtros auto limpantes como pre-filtro em agua de injecao para manutencao da vida util dos filtros polidores

    Energy Technology Data Exchange (ETDEWEB)

    Ramalhao, Adriano Gorga; Seno, Carlos Eduardo; Ribeiro, Alice [3M do Brasil Ltda., Sumare, SP (Brazil)

    2008-07-01

    The water injection treatment involves several units of treatment, which are defined and designed from data, some obtained from measurements, with other empirical formulas, others as a compromise, and that most of them varies. This variability can be covered by some filtration systems with greater flexibility. In the case of self cleaning filtration systems, they offer such flexibility due to its retro washing automated by metal cartridges that can extend up to fifty percent in the life of the filter end in cases of deterioration in water quality because of increased organic material for many reasons. (author)

  16. Snubber assembly for a control rod drive

    International Nuclear Information System (INIS)

    1976-01-01

    A snubber cartridge assembly is described which is mounted to the nozzle of a control rod drive mechanism to insure that it will be located within the liquid filled section of a nuclear reactor vessel whenever the control rod drive is assembled thereto. The snubber assembly includes a piston-mounted proximate to the control rod connecting end of the control rod drive leadscrew to allow the piston to travel within the liquid filled snubber cartridge and controllable exhaust the liquid during a 'scram' condition. The snubber cartridge provides three separate areas of increasing resistance to piston travel to insure a speedy but safe 'scram' of the control rod into the reactor

  17. Snubber assembly for a control rod drive

    International Nuclear Information System (INIS)

    Matthews, J.C.

    1978-01-01

    A snubber cartridge assembly is mounted to the nozzle of a control rod drive mechanism to insure that the snubber assembly will be located within the liquid filled section of a nuclear reactor vessel whenever the control rod drive is assembled thereto. The snubber assembly includes a piston mounted proximate to the control rod connecting end of the control rod drive leadscrew to allow the piston to travel within the liquid filled snubber cartridge and controllably exhaust liquid therefrom during a ''scram'' condition. The snubber cartridge provides three separate areas of increasing resistance to piston travel to insure a speedy but safe ''scram'' of the control rod into the reactor

  18. Development of a radiochemical method for analyzing radon gas in uranium mine atmospheres: covering the period February 3, 1975--March 31, 1976

    Energy Technology Data Exchange (ETDEWEB)

    Stein, L.; Shearer, J.A.; Hohorst, F.A.; Markun, F.

    1977-01-14

    A simplified radiochemical method has been developed for quantitatively analyzing radon gas in underground uranium mines. In this method, a measured volume of air is drawn by a pump through a drying tube and a cartridge containing dioxygenyl hexafluoroantimonate reagent. Radon is captured as a nonvolatile product. After radioactive equilibrium has been established between radon and its short-lived daughters (approximately 4 hours), the gamma-emission of the cartridge is measured with a scintillation counter. The amount of radon is then calculated from the gamma-emission rate. The effect of cartridge geometry, reagent load, and air flow rate upon collection efficiency and counting efficiency is reported.

  19. Development of a radiochemical method for analyzing radon gas in uranium mine atmospheres: covering the period February 3, 1975--March 31, 1976

    International Nuclear Information System (INIS)

    Stein, L.; Shearer, J.A.; Hohorst, F.A.; Markun, F.

    1977-01-01

    A simplified radiochemical method has been developed for quantitatively analyzing radon gas in underground uranium mines. In this method, a measured volume of air is drawn by a pump through a drying tube and a cartridge containing dioxygenyl hexafluoroantimonate reagent. Radon is captured as a nonvolatile product. After radioactive equilibrium has been established between radon and its short-lived daughters (approximately 4 hours), the gamma-emission of the cartridge is measured with a scintillation counter. The amount of radon is then calculated from the gamma-emission rate. The effect of cartridge geometry, reagent load, and air flow rate upon collection efficiency and counting efficiency is reported

  20. Intercomparison campaign of Contracted Partner Institutes 1997

    International Nuclear Information System (INIS)

    Reinen, H.A.J.M.; Tijsmans, M.H.; Van Tuinen, S.T.; Overwater, R.M.W.; Aldenkamp, F.J.

    1998-01-01

    The Dutch National Plan for Nuclear Emergency Planning and Response (EPR) is trained frequently. Intercomparison campaigns and exercises are part of this training for the Contracted Partner Institutes (CPI). The results of an intercomparison campaign in 1997 for the CPI are reported. Two carbon cartridges, one contaminated homogeneously and one inhomogeneously with 131 I, and a water sample contaminated with 134 Cs and 137 Cs were analysed by means of gamma spectroscopy. The results had to be faxed to RIVM within the time limits prescribed in the emergency protocols for CPI, i.e. 2 hours for the cartridges and 24 hours for the water sample. Most CPI reported in time. The results for the inhomogeneously contaminated cartridge are within 25% from the accepted reference value (ARV). For the homogeneously contaminated cartridge the results are within 40% from the ARV. In reality, the contamination of the cartridge will have an exponential profile, with most of the activity in the first few millimeters. In this situation results can be expected to be within 20% from the true value. The results for the water sample are within 5% from the ARV. Although most CPI have applied corrections for coincidence summing for 134 Cs there is still a systematic error of 4% for this nuclide. In regard of the requirements for measurements during emergency situations, the results of this intercomparison campaign are satisfactory

  1. A New Solid Phase Extraction for the Determination of Anthocyanins in Grapes

    Directory of Open Access Journals (Sweden)

    Marta Ferreiro-González

    2014-12-01

    Full Text Available A method for the concentration and cleaning of red grape extracts prior to the determination of anthocyanins by UPLC-DAD has been developed. This method is of special interest in the determination of phenolic maturity as it allows the analysis of the anthocyanins present in grapes. Several different SPE cartridges were assessed, including both C-18- and vinylbenzene-based cartridges. C-18-based cartridges presented a very low retention for the glucosylated anthocyanidins while vinylbenzene-based cartridges showed excellent retention for these compounds. The optimized method involves the initial conditioning of the cartridge using 10 mL of methanol and 10 mL of water, followed by loading of up to 100 mL of red grape extract. Ten mL of water was used in the washing step and anthocyanins were subsequently eluted using 1.5 mL of acidified methanol at pH 2. This method simplifies the determination of individual anthocyanins as, on the one hand, it cleans the sample of interference and, on the other hand, it increases the concentration to up to 25:1.5. The developed method has been validated with a range of different grapes and it has also been tested as a means of determining the different anthocyanins in grapes with different levels of maturity.

  2. Development of filters and housings for use on active plant

    International Nuclear Information System (INIS)

    Hackney, S.; Pratt, R.P.

    1983-01-01

    New designs of housings for conventional HEPA filters have been developed and are now in use. A further design is planned for future use. The main features to be developed are the engineering of double door systems to replace bag posting and other methods of filter changing which expose personnel to hazardous environments and the addition of a secondary containment to reduce the role of the gasket seal in the filtration efficiency. Also under development are circular geometry filters of HEPA standard which offer significant advantages over rectangular filters for applications requiring remote shielded change facilities. Two types of filter construction are being evaluated, conventional radial flow cartridge filters and spiral-wound, axial-flow filters. The application of circular filters for primary filter systems on active plant is in hand. A push-through change system has been developed for a new cell facility under construction at Harwell. Existing rectangular filters on a high activity cell are being replaced with clusters of small cartridge filters to overcome changing and disposal problems. A similar system but using 1700 m 3 /h filters for large volume off-gas treatment is also being studied. A remote change shielded filter installation is being developed for use in high alpha, beta, gamma extract systems. The design incorporates large cartridge filters in sealed drums with remote transfer and connection to duct work in the facility. A novel application of the use of double-lid technology removes the need for separate shut off dampers and enables the drums to be sealed for all transfer operations

  3. 49 CFR 176.84 - Other requirements for stowage and segregation for cargo vessels and passenger vessels.

    Science.gov (United States)

    2010-10-01

    ... persons on passenger vessels. 94 Plastic jerricans and plastic drums not permitted under deck. 95 Stow... Stowage category “04” for projectiles or cartridges for guns, cannons or mortars; Stowage category “08... projectiles or cartridges for guns, cannons or mortars; Stowage category “07” for other types; magazines must...

  4. 40 CFR 63.11511 - What definitions apply to this subpart?

    Science.gov (United States)

    2010-07-01

    ... detonation gun spraying. Water curtain means a type of control device that draws the exhaust stream through a... emissions points and then convey the captured gas stream to a control device, as part of a complete control..., plenums, and fans. Cartridge filter means a type of control device that uses perforated metal cartridges...

  5. Dosagem de artemisinina em Artemisia annua L. por cromatografia líquida de alta eficiência com detecção por índice de refração

    Directory of Open Access Journals (Sweden)

    Vera Lúcia Garcia Rehder

    Full Text Available Artemisinin is a sesquiterpene lactone used in treatment of chloroquine-resistant malaria. This paper presents high-performance liquid chromatographic assay for artemisinin in leaves of A. annua using differential refractometer detector and a single step of clean-up in a silica cartridge. The average of recoveries were 95% and the limit of quantification was 0,21% p/p using 200 mg of the leaves. This method was found to be simple, robust and relatively rapid.

  6. Behaviours, thoughts and perceptions around mealtime insulin usage and wastage among people with type 1 and type 2 diabetes mellitus: A cross-sectional survey study.

    Science.gov (United States)

    Van Brunt, Kate; Pedersini, Riccardo; Rooney, Jillian; Corrigan, Sheila M

    2017-04-01

    People with diabetes who use mealtime insulin (MTI) were surveyed about insulin wastage and injection habits when insufficient insulin remains in a disposable prefilled pen/cartridge to administer a full dose in a single injection. Cross-sectional, online, self-reported survey of MTI usage/wastage behaviour in 400 adults with type 1 (n=120) or type 2 (n=280) diabetes mellitus administering >20units/day of MTI via 100units/ml prefilled pens/cartridges for ⩾1month, conducted in France, Germany, Italy and UK. Participants' mean±standard deviation age was 54.5±12.2years, body mass index was 29.9±7.2kg/m 2 and duration of MTI therapy was 8.6±7.8years. They administered 3.7±5.9 injections/day with meals, using 11.3±18.0 prefilled pens/cartridges per month. Overall, 63.5% split the dose across two prefilled pens/cartridges (i.e. administered two injections to obtain a full dose), 15.0% used just what remained in their current pen (i.e. took a lower-than-prescribed dose) and 36.3% discarded prefilled pens/cartridges still containing insulin (i.e. took full dose with new pen). The latter participants discarded a mean 5.5±8.2 prefilled pens/cartridges monthly still containing insulin, each containing 8.6±8.7 units of insulin. Participants who wasted insulin considered it frustrating, time-consuming and painful to inject twice. Patients taking >20units/day MTI can find transitions between insulin pens challenging. This study highlights the need to identify ways of improving transitions between pens to make transitions easier for insulin users, which could potentially improve adherence to prescribed doses and reduce waste. Copyright © 2016 Eli Lilly and Company. Published by Elsevier B.V. All rights reserved.

  7. Anesthetic Efficacy of a Combination of 4% Prilocaine/2% Lidocaine with Epinephrine for the Inferior Alveolar Nerve Block: A Prospective, Randomized, Double-blind Study.

    Science.gov (United States)

    Cook, Olivia; Nusstein, John; Drum, Melissa; Fowler, Sara; Reader, Al; Draper, John

    2018-05-01

    Prilocaine plain has a high pH and concentration (4%), which could decrease the pain of injection and increase success. The purpose of this study was to compare pain associated with anesthetic solution deposition and the degree of pulpal anesthesia obtained with the combination of prilocaine and lidocaine versus a lidocaine and lidocaine combination when used for inferior alveolar nerve blocks (IANBs). One hundred eighteen asymptomatic subjects were randomly given a combination of 1 cartridge of 4% prilocaine plain plus 1 cartridge of 2% lidocaine with 1:100,000 epinephrine or a combination of 2 cartridges of 2% lidocaine with 1:100,000 epinephrine for the IANB at 2 separate appointments. Subjects rated the pain associated with anesthetic solution deposition of injection. Mandibular teeth were tested with an electric pulp tester every 4 minutes for 57 minutes. Anesthesia was considered successful when 2 consecutive 80 readings were obtained within 17 minutes and the 80 reading was continuously sustained for 57 minutes. Comparisons for anesthetic success were analyzed using the exact McNemar test, and pain ratings associated with anesthetic solution deposition were analyzed using multiple Wilcoxon matched pairs signed rank tests; both were adjusted using the step-down Bonferroni method of Holm. Four percent prilocaine plain was significantly less painful upon anesthetic solution deposition. Pulpal anesthetic success was not significantly different between the 2 combinations. The combination of 4% prilocaine plain plus 2% lidocaine with 1:100,000 epinephrine did not increase pulpal anesthetic success for IANBs compared with a combination of 2 cartridges of 2% lidocaine with 1:100,000 epinephrine. Pain associated with anesthetic solution deposition from the first cartridge of 4% prilocaine plain was significantly less when compared with the first cartridge of 2% lidocaine with 1:100,000 epinephrine. Copyright © 2018 American Association of Endodontists. Published

  8. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  9. Apparatus for inspecting the quality of nuclear fuel rod ends

    International Nuclear Information System (INIS)

    Brashier, R.W.; Pfau, E.D.

    1990-01-01

    This patent describes an apparatus for inspecting the quality of both ends of nuclear fuel rods. It comprises: a housing including a pair of longitudinally separated slots for receiving X-ray downwardly therethrough from an external source and so as to define first and second longitudinally spaced apart operating positions, means for serially guiding nuclear fuel rods longitudinally through the housing and to a first rod position wherein the forward ends of the rods are aligned below the first operating position and to a second rod position wherein the rear ends of the rods are aligned below the second operating position, belt conveyor assembly means for serially advancing X-ray film cartridges longitudinally through the housing and below the rods, and so that each cartridge may be selectively aligned below the first and second operating positions; and table means supported by the conveyor frame for selectively lifting the film cartridges supported by the belts and so that the conveyor belts may be advanced while the film cartridges are held stationary

  10. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  11. Volatile organic compound analysis in wood combustion and meat cooking emissions

    International Nuclear Information System (INIS)

    Zielinska, B.; McDonald, J.

    1999-01-01

    Residential wood combustion and meat cooking emissions were each analyzed for volatile organic compounds (VOC). Emissions were diluted 60--100 times, cooled to ambient temperature, and allowed 80 seconds for condensation prior to collection with the aid of a DRI-constructed dilution stack sampler. Fireplace and wood-stove emissions testing was conducted at the DRI facilities. Wood type, wood moisture, burn rate, and fuel load were varied for different experiments. Meat emissions testing was conducted at the CE-CERT stationary emissions lab, University of California, Riverside. Meat type, fat content, and cooking appliance were changed in different tests. VOCs were collected using stainless-steel 6 L canisters and Tenax cartridges, whereas for carbonyl compound collection 2,4-dinitrophenylhydrazine (DNPH)-impregnated C 18 SepPack cartridges were used. Analysis of VOC collected with canisters and Tenax cartridges was conducted by Gas Chromatography/Mass Spectrometry (GC/MS) and by GC/FID/ECD (flame ionization detection/electron capture detection). DNPH-impregnated cartridges were analyzed for fourteen C 1 --C 7 carbonyl compounds, using the HPLC method. The results of these measurements are discussed

  12. A simple method to compare firing pin marks using stereomicroscope and Microsoft office (Windows 8) tools.

    Science.gov (United States)

    Suresh, R

    2017-08-01

    Pertinent marks of fired cartridge cases such as firing pin, breech face, extractor, ejector, etc. are used for firearm identification. A non-standard semiautomatic pistol and four .22rim fire cartridges (head stamp KF) is used for known source comparison study. Two test fired cartridge cases are examined under stereomicroscope. The characteristic marks are captured by digital camera and comparative analysis of striation marks is done by using different tools available in the Microsoft word (Windows 8) of a computer system. The similarities of striation marks thus obtained are highly convincing to identify the firearm. In this paper, an effort has been made to study and compare the striation marks of two fired cartridge cases using stereomicroscope, digital camera and computer system. Comparison microscope is not used in this study. The method described in this study is simple, cost effective, transport to field study and can be equipped in a crime scene vehicle to facilitate immediate on spot examination. The findings may be highly helpful to the forensic community, law enforcement agencies and students. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Monitoring of estrogens, pesticides and bisphenol A in natural waters and drinking water treatment plants by solid-phase extraction-liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Rodriguez-Mozaz, Sara; de Alda, Maria J López; Barceló, Damià

    2004-08-06

    A multi-residue analytical method has been developed for the determination of various classes of selected endocrine disruptors. This method allows the simultaneous extraction and quantification of different estrogens (estradiol, estrone, estriol, estradiol-17-glucuronide, estradiol diacetate, estrone-3-sulfate, ethynyl estradiol and diethylstilbestrol), pesticides (atrazine, simazine, desethylatrazine, isoproturon and diuron), and bisphenol A in natural waters. In the method developed, 500 ml of water are preconcentrated on LiChrolut RP-18 cartridges. Further analysis is carried out by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure chemical ionisation (APCI) in the positive ion mode for determination of pesticides and electrospray in the negative ionisation mode for determination of estrogens and bisphenol A. Recoveries for most compounds were between 90 and 119%, except for bisphenol A (81%) and diethylstilbestrol (70%), with relative standard deviations below 20%. Limits of detection ranged between 2 and 15 ng/l. The method was used to study the occurrence of the selected pollutants in surface and groundwater used for abstraction of drinking water in a waterworks and to evaluate the removal efficiency of the different water treatments applied. Water samples from the river, the aquifer, and after each treatment stage (sand filtration, ozonation, activated carbon filtration and post-chlorination) were taken monthly from February to August of 2002. The presence in river water of atrazine, simazine, diuron and bisphenol A were relatively frequent at concentrations usually below 0.1 microg/l. Lower levels, below 0.02 microg/l, were usual for isoproturon. Estrone-3-sulfate and estrone were detected occasionally in the river. Most of the compounds were completely removed during the water treatment, especially after activated carbon filtration.

  14. Basic hydrolysis of 1, 3, 4, 6-tetra-O-acetyl-2-[18F] fluoro-D-glucose on solid phase extraction

    International Nuclear Information System (INIS)

    Zhang Jinming; Tian Jiahe; He Yijie; Huan Dingcai; Liu Boli

    2003-01-01

    A new base hydrolysis method are used for 1, 3, 4, 6-tetra-O-acetyl-2-[ 18 F] fluoro-D-glucose on solid phase extraction. The labeled intermediate is trapped on an active C-18 solid phase extraction cartridge, and hydrolyzed in cartridge with 1 mL 2 mol/L NaOH at room temperature. The results show that there are over 99% of the labeled intermediate being turned into 18 F-FDG within 2 min. It is easy to get 18 F-FDG after neutralized with phosphate buffer, purified by C-18 and Alumina cartridge. The basic hydrolysis on solid extraction is a simple method for preparation of 18 F-FDG

  15. Linear and/or curvilinear rail mount system

    Science.gov (United States)

    Thomas, Jackie D. (Inventor); Harris, Lawanna L. (Inventor)

    2012-01-01

    One or more linear and/or curvilinear mounting rails are coupled to a structure. Each mounting rail defines a channel and at least one cartridge assembly is engaged in the channel. Each cartridge assembly includes a housing that slides within the channel. The housing defines a curvilinearly-shaped recess longitudinally aligned with the channel when the housing is in engagement therewith. The cartridge assembly also includes a cleat fitted in the recess for sliding engagement therealong. The cleat can be coupled to a fastener that passes through the mounting rail and the housing when the housing is so-engaged in the channel. The cleat is positioned in the recess by a position of the fastener.

  16. Apparatus for rendering at least a portion of a device inoperable and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Steffler, Eric D.; Hartenstein, Steven D.; Wallace, Ronald S.

    2016-11-08

    Apparatus for rendering at least a portion of a device inoperable may include a containment structure having a first compartment that is configured to receive a device therein and a movable member configured to receive a cartridge having reactant material therein. The movable member is configured to be inserted into the first compartment of the containment structure and to ignite the reactant material within the cartridge. Methods of rendering at least a portion of a device inoperable may include disposing the device into the first compartment of the containment structure, inserting the movable member into the first compartment of the containment structure, igniting the reactant material in the cartridge, and expelling molten metal onto the device.

  17. Water reactive hydrogen fuel cell power system

    Science.gov (United States)

    Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

    2014-01-21

    A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into a fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

  18. Efficacy of orally administered prednisolone versus partial endodontic treatment on pain reduction in emergency care of acute irreversible pulpitis of mandibular molars: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Kérourédan, Olivia; Jallon, Léonard; Perez, Paul; Germain, Christine; Péli, Jean-François; Oriez, Dominique; Fricain, Jean-Christophe; Arrivé, Elise; Devillard, Raphaël

    2017-03-28

    Irreversible pulpitis is a highly painful inflammatory condition of the dental pulp which represents a common dental emergency. Recommended care is partial endodontic treatment. The dental literature reports major difficulties in achieving adequate analgesia to perform this emergency treatment, especially in the case of mandibular molars. In current practice, short-course, orally administered corticotherapy is used for the management of oral pain of inflammatory origin. The efficacy of intraosseous local steroid injections for irreversible pulpitis in mandibular molars has already been demonstrated but resulted in local comorbidities. Oral administration of short-course prednisolone is simple and safe but its efficacy to manage pain caused by irreversible pulpitis has not yet been demonstrated. This trial aims to evaluate the noninferiority of short-course, orally administered corticotherapy versus partial endodontic treatment for the emergency care of irreversible pulpitis in mandibular molars. This study is a noninferiority, open-label, randomized controlled clinical trial conducted at the Bordeaux University Hospital. One hundred and twenty subjects will be randomized in two 1:1 parallel arms: the intervention arm will receive one oral dose of prednisolone (1 mg/kg) during the emergency visit, followed by one morning dose each day for 3 days and the reference arm will receive partial endodontic treatment. Both groups will receive planned complete endodontic treatment 72 h after enrollment. The primary outcome is the proportion of patients with pain intensity below 5 on a Numeric Scale 24 h after the emergency visit. Secondary outcomes include comfort during care, the number of injected anesthetic cartridges when performing complete endodontic treatment, the number of antalgic drugs and the number of patients coming back for consultation after 72 h. This randomized trial will assess the ability of short-term corticotherapy to reduce pain in irreversible

  19. Study of interfacial phenomena of organo-chlorinated steam adsorption on a microporous adsorbent. Case of tri chloro-1,1,1 ethane on activated charcoal

    International Nuclear Information System (INIS)

    Escallon, S.

    1991-06-01

    This study involves the construction and the perfecting of a test system for evaluating the service life of organic vapor cartridges versus 1,1,1 -trichloroethane. Thermogravimetric measurements were carried on in order to suggest a field method to reactive these cartridges, using hot air flow system. Assessment of adsorption rate during experiment is measured with a new electrical method. (author)

  20. Electronic Vapor Cigarette Battery Explosion Causing Shotgun-like Superficial Wounds and Contusion

    Directory of Open Access Journals (Sweden)

    Siri Shastry, MD

    2016-03-01

    Full Text Available INTRODUCTION Electronic vapor cigarettes (E-cigarettes were created in 2003 as an alternative to traditional tobacco cigarettes. E-cigarettes have been available in the United States since 2006.1 The typical E-cigarette consists of a cartridge that contains liquid, an atomizer that heats the liquid (i.e. acts as a vaporizer, as well as a battery. The liquid contained within the cartridge contains nicotine, propylene glycol and/ or glycerol as well as flavorings. The consumer uses an E-cigarette through either pushing a button or inhalation, which triggers heating and therefore aerosolizes the liquid within the cartridge, emulating cigarette “smoke.” The newest E-cigarettes are larger than nicotine cigarettes and employ stronger, rechargeable batteries as a power source.2,3

  1. The determination of radiocaesium in sea and fresh waters

    International Nuclear Information System (INIS)

    Baker, C.W.

    1975-10-01

    The caesium is adsorbed on to a cartridge of silica gel impregnated with ammonium molybdophosphate from 50 litres of filtered water, adjusted to pH 2 with nitric acid. The cartridge is then placed in a well crystal detector and gamma counted. An additional separation step is required if zirconium-95/niobium-95 contamination has occurred, as shown by gamma spectrometric analysis of the cartridge. The measurement of caesium-137 and caesium-134 is by conventional γ-spectrometry. The output of the analysing system is ASCII paper tape, and a PDP-8 computer is used to convert this spectral information to activity of caesium-137 and -134 in pCi l -1 at the time of sample collection. (U.K.)

  2. Analysis of nitrosamines in water by automated SPE and isotope dilution GC/HRMS Occurrence in the different steps of a drinking water treatment plant, and in chlorinated samples from a reservoir and a sewage treatment plant effluent.

    Science.gov (United States)

    Planas, Carles; Palacios, Oscar; Ventura, Francesc; Rivera, Josep; Caixach, Josep

    2008-08-15

    A method based on automated solid-phase extraction (SPE) and isotope dilution gas chromatography/high resolution mass spectrometry (GC/HRMS) has been developed for the analysis of nine nitrosamines in water samples. The combination of automated SPE and GC/HRMS for the analysis of nitrosamines has not been reported previously. The method shows as advantages the selectivity and sensitivity of GC/HRMS analysis and the high efficiency of automated SPE with coconut charcoal EPA 521 cartridges. Low method detection limits (MDLs) were achieved, along with a greater facility of the procedure and less dependence on the operator with regard to the methods based on manual SPE. Quality requirements for isotope dilution-based methods were accomplished for most analysed nitrosamines, regarding to trueness (80-120%), method precision (water samples (16 samples from a drinking water treatment plant {DWTP}, 2 chlorinated samples from a sewage treatment plant {STP} effluent, and 1 chlorinated sample from a reservoir) were analysed. Concentrations of nitrosamines in the STP effluent were 309.4 and 730.2 ng/L, being higher when higher doses of chlorine were applied. N-Nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) were the main compounds identified in the STP effluent, and NDEA was detected above 200 ng/L, regulatory level for NDMA in effluents stated in Ontario (Canada). Lower concentrations of nitrosamines were found in the reservoir (20.3 ng/L) and in the DWTP samples (n.d. -28.6 ng/L). NDMA and NDEA were respectively found in the reservoir and in treated and highly chlorinated DWTP samples at concentrations above 10 ng/L (guide value established in different countries). The highest concentrations of nitrosamines were found after chlorination and ozonation processes (ozonated, treated and highly chlorinated water) in DWTP samples.

  3. Evaluation of modified boehm titration methods for use with biochars.

    Science.gov (United States)

    Fidel, Rivka B; Laird, David A; Thompson, Michael L

    2013-11-01

    The Boehm titration, originally developed to quantify organic functional groups of carbon blacks and activated carbons in discrete pK ranges, has received growing attention for analyzing biochar. However, properties that distinguish biochar from carbon black and activated carbon, including greater carbon solubility and higher ash content, may render the original Boehm titration method unreliable for use with biochars. Here we use seven biochars and one reference carbon black to evaluate three Boehm titration methods that use (i) acidification followed by sparging (sparge method), (ii) centrifugation after treatment with BaCl (barium method), and (iii) a solid-phase extraction cartridge followed by acidification and sparging (cartridge method) to remove carbonates and dissolved organic compounds (DOC) from the Boehm extracts before titration. Our results for the various combinations of Boehm reactants and methods indicate that no one method was free of bias for all three Boehm reactants and that the cartridge method showed evidence of bias for all pK ranges. By process of elimination, we found that a combination of the sparge method for quantifying functional groups in the lowest pK range (∼5 to 6.4), and the barium method for quantifying functional groups in the higher pK ranges (∼6.4 to 10.3 and ∼10.3 to 13) to be free of evidence for bias. We caution, however, that further testing is needed and that all Boehm titration results for biochars should be considered suspect unless efforts were undertaken to remove ash and prevent interference from DOC. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  4. Investigation of solid phase sorbents for the pre- concentration of pads from aqueous medium and their quantitation by high performance liquid chromatography-UV detection

    International Nuclear Information System (INIS)

    Waqar, F.; Jan, S.; Muhammad, B.; Ahmad, S.; Riaz, M.; Akram, N.

    2005-01-01

    A solid phase extraction method was optimized for the pre-concentration of polyaromatic hydrocarbons (PAHs) in water samples. Graphite powder and Lab scale locally synthesized styrene divinylbenzene (SDVB) Copolymer were used as sorbents for the extraction of PAHs and compared with commercially used C18 solid phase extraction cartridge (SPE). Various parameters were optimized to evaluate the extraction efficiencies, the best results were obtained by proper conditioning of extraction cartridges and desorption with suitable solvent. Percentage recoveries were enhanced by rinsing the sample bottles with acetonitrile and combining the rinse with the sample extract. Quantitative analysis was performed by High performance Liquid chromatography (HPLC) with UV detection. Many other parameters, including optimization of mobile phase, selection of HPLC Columns, sample-loading flow rate on extraction cartridge and weight of sorbent were performed to get optimal results. Percent recoveries obtained with synthesized copolymer were comparable with commercial cartridge, while graphite powder showed excellent retention but very poor recoveries. Obtained recoveries of selected PAHs were ranged from 80-87% with relative standard deviation <6%. Developed method was applied for the analysis of drinking water samples(author)

  5. Study of gunshot residues from Sintox® ammunition containing marking substances

    Directory of Open Access Journals (Sweden)

    Júlia Polovková

    2015-12-01

    Full Text Available Two types of factory marked Sintox® ammunition were investigated from the composition of gunshot residue particles (GSR and occurrence of marking substance points of view. The experiments were carried out with two cartridges of caliber 9 mm Luger (9 × 19 Parabellum of two producers (Ruag Ammotec, Switzerland and Men, Germany. The first cartridge (type Action 4, Ruag Ammotec contains gadolinium as a marking element, while the other cartridge (type PEP II, Men is marked with gallium in gunpowder. Scanning electron microscopy equipped with EDAX analyzer (SEM/EDX was used to detect and analyze the GSR particles in samples collected from the cartridges, barrels and shooter’s hands. Besides those, particles from the hit clothes placed at different shooting distances were collected and analyzed. The spreading of GSR cloud from the gun was observed using the high-speed camera. Results obtained clearly revealed that the way of ammunition production/construction and type of marking of ammunition can significantly influence the presence and detection reliability of marking elements in GSR. The detectability is affected also by the shooting distance.

  6. Comparison of iSTAT and EPOC Blood Analyzers

    Science.gov (United States)

    2017-10-25

    gold standard laboratory testing to two POC devices—iSTAT and EPOC—with and without expired cartridges and conditioned cartridges. The study was...analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared gold standard laboratory...BE) extra cellular fluid, BE blood, sulfur dioxide, Hgb) to gold standard measurements conducted by the central laboratory. The study also compared

  7. Hazard categorization of K Basin water filtration upgrade project

    International Nuclear Information System (INIS)

    Conn, K.R.

    1995-01-01

    This supporting document provides the hazards categorization for the K Basin Water Filtration Upgrade Project at K East. All activities associated with the project are less than Hazard Category 3, except for the handling of the ECO-ROK liners containing spent filter cartridges. All activities involving the handling of liners, containing spent cartridges, by monorail, forklift or mobile crane are classified as Hazard Category 3

  8. A computer controlled tele-cobalt unit

    International Nuclear Information System (INIS)

    Brace, J.A.

    1982-01-01

    A computer controlled cobalt treatment unit was commissioned for treating patients in January 1980. Initially the controlling computer was a minicomputer, but now the control of the therapy unit is by a microcomputer. The treatment files, which specify the movement and configurations necessary to deliver the prescribed dose, are produced on the minicomputer and then transferred to the microcomputer using minitape cartridges. The actual treatment unit is based on a standard cobalt unit with a few additional features e.g. the drive motors can be controlled either by the computer or manually. Since the treatment unit is used for both manual and automatic treatments, the operational procedure under computer control is made to closely follow the manual procedure for a single field treatment. The necessary safety features which protect against human, hardware and software errors as well as the advantages and disadvantages of computer controlled radiotherapy are discussed

  9. Investigation of Filtration Membranes from the Dairy Protein Industry for Residual Fouling Using Infrared Spectroscopy and Chemometrics

    DEFF Research Database (Denmark)

    Jensen, Jannie Krog

    the reversible fouling can be removed/cleaned. The aim of this thesis is to investigate the residual fouling that is deposited on ultrafiltration and microfiltration membranes after usage. The membrane surfaces are investigated using infrared spectroscopy with an attenuated reflectance sampling unit...... and this is thesis work highlights the strengths and weaknesses of using infrared spectroscopy to investigate residual fouling on membranes and in particular the challenges with the infrared penetration depth when layering in the samples occurs. Real size production membrane cartridges at different stages of use...... microfiltration membrane cartridges were investigated with Attenuated- Total-Reflection Fourier-Transform-Infrared (ATR FT-IR) to map the residual fouling on both types of cartridges. The height of the characteristic amide peaks from proteins were used to determine the relative concentrations. The first...

  10. Pneumatic probe with laser interferometer

    International Nuclear Information System (INIS)

    Wilkens, P.H.

    1978-01-01

    Improvements to upgrade the accuracy of Rotacon probes by a complete redesign of probe to include a Michelson interferometer to replace the existing long-range capacity transducer are described. This has resulted in a compact and interchangeable probe cartridge with a 3 μin. resolution and accuracy; the cartridge can be installed and replaced in the Rotacon gauge with the minimum of realignment, which should reduce our dependence on operator skill. In addition, the stylus contact force can be reduced to 750 mg for the contacting types, but an alternative feature, which we are still developing, will use a gas jet cushion in place of the stylus to provide a noncontacting version of the same basic probe cartridge. This device is very sensitive to external vibration effects because it is virtually frictionless

  11. Life cycle assessment study on polishing units for use of treated wastewater in agricultural reuse.

    Science.gov (United States)

    Büyükkamacı, Nurdan; Karaca, Gökçe

    2017-12-01

    A life cycle assessment (LCA) approach was used in the assessment of environmental impacts of some polishing units for reuse of wastewater treatment plant effluents in agricultural irrigation. These alternative polishing units were assessed: (1) microfiltration and ultraviolet (UV) disinfection, (2) cartridge filter and ultrafiltration (UF), and (3) just UV disinfection. Two different energy sources, electric grid mix and natural gas, were considered to assess the environmental impacts of them. Afterwards, the effluent of each case was evaluated against the criteria required for irrigation of sensitive crops corresponding to Turkey regulations. Evaluation of environmental impacts was carried out with GaBi 6.1 LCA software. The overall conclusion of this study is that higher electricity consumption causes higher environmental effects. The results of the study revealed that cartridge filter and UF in combination with electric grid mix has the largest impact on the environment for almost all impact categories. In general, the most environmentally friendly solution is UV disinfection. The study revealed environmental impacts for three alternatives drawing attention to the importance of the choice of the most appropriate polishing processes and energy sources for reuse applications.

  12. Simultaneous HPLC-F analysis of three recent antiepileptic drugs in human plasma.

    Science.gov (United States)

    Mercolini, Laura; Mandrioli, Roberto; Amore, Mario; Raggi, Maria Augusta

    2010-09-21

    An original high-performance liquid chromatographic method with fluorescence detection is presented for the simultaneous determination of the three antiepileptic drugs gabapentin, vigabatrin and topiramate in human plasma. After pre-column derivatisation with dansyl chloride, the analytes were separated on a Hydro-RP column with a mobile phase composed of phosphate buffer (55%) and acetonitrile (45%) and detected at lambda(em)=500 nm, exciting at 300 nm. An original pre-treatment procedure on biological samples, based on solid-phase extraction with MCX cartridges for gabapentin and vigabatrin, and with Plexa cartridges for topiramate, gave high extraction yields (>91%), satisfactory precision (RSDvigabatrin and in the 1.0-50.0 microg mL(-1) range for topiramate, with limits of detection (LODs) between 0.1 and 0.3 microg mL(-1). After validation, the method was successfully applied to some plasma samples from patients undergoing therapy with one or more of these drugs. Accuracy results were satisfactory (recovery >91%). Therefore, the method seems to be suitable for the therapeutic drug monitoring (TDM) of patients treated with gabapentin, vigabatrin and topiramate. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Effect of clarification process on the removal of pesticide residues in red wine and comparison with white wine.

    Science.gov (United States)

    Doulia, Danae S; Anagnos, Efstathios K; Liapis, Konstantinos S; Klimentzos, Demetrios A

    2018-04-30

    The aim of this study was to determine the potential of seven clarifying agents to remove pesticides in red wine. The presence of pesticides in wine consists a great problem for winemakers and therefore, results on pesticide removal by clarification are very useful for taking a decision on the appropriate adsorbent. The selection of an efficient adsorbent can be based on data correlating pesticide removal in red wine to pesticides' properties, given the great number and variety of pesticides used. So, this experimental work is focused on the collection of results with regard to pesticide removal by clarification using a great number of pesticides and fining agents. A Greek red wine, fortified with single solutions and mixtures of 23 or 9 pesticides was studied. The seven fining agents, used at two concentrations, were activated carbon, bentonite, polyvinylpolypyrrolidone (PVPP), gelatin, egg albumin, isinglass-fish glue, and casein. Pesticides were selected with a wide range of properties (octanol-water partition coefficient (log K ow ) 2.7-6.3 and water solubility 0.0002-142) and belong to 11 chemical groups. Solid phase extraction (SPE) followed by gas chromatography (GC) with electron capture detector (ECD) were performed to analyze pesticide residues of the clarified fortified wine. The correlation of the clarifying agents' effectiveness to pesticide's chemical structure and properties (log K ow , water solubility) was investigated. The antagonistic and/or synergistic effects, occurring among the pesticides in the mixtures, were calculated by indices. Pesticide removal effectiveness results of the red wine were compared to those obtained from a white wine under the same experimental conditions and discussed. The order of decreasing adsorbent effectiveness (mixture of 23 pesticides) was: activated carbon 40% > gelatin 23% > egg albumin 21% > PVPP 18% > casein 12% > bentonite 7%. Isinglass showed 12% removal at the highest permitted concentration. In the case of

  14. Liquid filter for liquids containing radioactive materials

    International Nuclear Information System (INIS)

    Rohleder, N.; Schwarz, F.

    1986-01-01

    A device for filtering radioactive liquids loaded with solids is described, which has a pressure-resistant housing with a lid and an incomer for the turbid liquid and a collecting space and drain for the filtrate at the bottom of the housing. A filter cartridge is present in this housing. Such a filtering device must be suitable for use in nuclear plants, must be easy to replace by remote control and must minimise the carrying over of radioactive particles. This problem should be solved by the filter cartridge consisting of a large number of horizontal filter plates stacked above one another, which carry a deep layer filter material acting in the sub-micron range. The turbid liquid runs into the centre of the stack of filter plates via a vertical central duct. The intermediate spaces between the filter places are connected to this central duct via the layer of filter material. The filter plates are sealed against one another on the outer circumference and have radial drain openings for the filtrate on the outside. The central duct is sealed at the lower end by a plate. When the filter cartridge is replaced, the radioactive waste in the filter cartridge remains safely enclosed and can be conditioned in suitable containers. (orig.) [de

  15. Characterization of materials eliciting foreign body reaction in stapled human gastrointestinal anastomoses.

    Science.gov (United States)

    Lim, C B B; Goldin, R D; Darzi, A; Hanna, G B

    2008-08-01

    Staples are made of titanium, which elicits minimal tissue reaction. The authors have encountered foreign body reaction associated with stapled human gastrointestinal anastomoses, although the literature has no reports of this. The aim of this study was to identify the refractile foreign materials causing this reaction. Histological sections were taken from 14 gastrointestinal specimens from patients with a history of a stapled anastomosis within the specimen excised. These were reviewed by light and polarization microscopy. Scanning electron microscopy and energy dispersive X-ray analysis were carried out on these sections, staples and stapler cartridges used for gastrointestinal surgery. Foreign bodies rich in fluorine were found in three patients, and those rich in carbon in 12. Other elements identified included oxygen, calcium, sodium, potassium, magnesium, aluminium and silicon. One specimen was found to contain titanium with no surrounding foreign body reaction. Stapler cartridges contained carbon, oxygen, fluorine, calcium, sodium, potassium, magnesium, aluminium, silicon and traces of titanium. Staples were composed of pure titanium with some fibrous material on the surface containing elements found in stapler cartridges. The presence of foreign body reaction was confirmed in stapled human gastrointestinal anastomoses. The source of refractile materials eliciting this reaction was the stapler cartridges. (c) 2008 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  16. Fluid Delivery System For Capillary Electrophoretic Applications.

    Science.gov (United States)

    Li, Qingbo; Liu, Changsheng; Kane, Thomas E.; Kernan, John R.; Sonnenschein, Bernard; Sharer, Michael V.

    2002-04-23

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  17. Automated Parallel Capillary Electrophoretic System

    Science.gov (United States)

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2000-02-22

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  18. Motorized Positioning Apparatus Having Coaxial Carrousels.

    Science.gov (United States)

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2002-04-02

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  19. Effects of thermal treatments during cooking, microwave oven and boiling, on the unconjugated microcystin concentration in muscle of fish (Oreochromis niloticus).

    Science.gov (United States)

    Guzmán-Guillén, Remedios; Prieto, Ana I; Moreno, Isabel; Soria, Ma Eugenia; Cameán, Ana M

    2011-09-01

    Understanding the factors that contribute to the risk from fish consumption is a relevant public health concern due to potential adverse effects of cyanobacterial toxins. The aim of this work was to study the influence of two usual cooking practices, microwave oven and boiling, on the microcystin (MCs) concentration in fish muscle (Tilapia, Oreochromis niloticus) spiked with a stock solution (500 μL) containing a mixture of three toxins (MC-LR, MC-RR, and MC-YR) (1.5 μg/mL of each toxin). Two different variables were investigated: time of cooking in the microwaves treatment (1 or 5 min), and way of boiling, "boiled muscle" or "continuously heated muscle". All samples were then lyophilized and MCs were extracted and purified (Oasis HLB cartridge) and quantified by HPLC-MS. Furthermore, the waters in which the samples boiled were also analyzed after their purification. The results suggest a reduction on MC-LR (36%) and MC-YR (24.6%) in samples cooked in the microwave for 5 min. Major changes were found when the fish was cooked by the continuous boiling, with a decrease of 45.0% (MC-RR), 56.4% (MC-YR) and 59.3% (MC-LR). More studies are necessary to elucidate the mechanisms involved when aquatic food is submitted to usual cooking practices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Optimization of filter loading

    International Nuclear Information System (INIS)

    Turney, J.H.; Gardiner, D.E.; Sacramento Municipal Utility District, Herald, CA)

    1985-01-01

    The introduction of 10 CFR Part 61 has created potential difficulties in the disposal of spent cartridge filters. When this report was prepared, Rancho Seco had no method of packaging and disposing of class B or C filters. This work examined methods to minimize the total operating cost of cartridge filters while maintaining them below the class A limit. It was found that by encapsulating filters in cement the filter operating costs could be minimized

  1. Intelligent front-end sample preparation tool using acoustic streaming.

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, Erika J.; McClain, Jaime L.; Murton, Jaclyn K.; Edwards, Thayne L.; Achyuthan, Komandoor E.; Branch, Darren W.; Clem, Paul Gilbert; Anderson, John Mueller; James, Conrad D.; Smith, Gennifer; Kotulski, Joseph Daniel

    2009-09-01

    We have successfully developed a nucleic acid extraction system based on a microacoustic lysis array coupled to an integrated nucleic acid extraction system all on a single cartridge. The microacoustic lysing array is based on 36{sup o} Y cut lithium niobate, which couples bulk acoustic waves (BAW) into the microchannels. The microchannels were fabricated using Mylar laminates and fused silica to form acoustic-fluidic interface cartridges. The transducer array consists of four active elements directed for cell lysis and one optional BAW element for mixing on the cartridge. The lysis system was modeled using one dimensional (1D) transmission line and two dimensional (2D) FEM models. For input powers required to lyse cells, the flow rate dictated the temperature change across the lysing region. From the computational models, a flow rate of 10 {micro}L/min produced a temperature rise of 23.2 C and only 6.7 C when flowing at 60 {micro}L/min. The measured temperature changes were 5 C less than the model. The computational models also permitted optimization of the acoustic coupling to the microchannel region and revealed the potential impact of thermal effects if not controlled. Using E. coli, we achieved a lysing efficacy of 49.9 {+-} 29.92 % based on a cell viability assay with a 757.2 % increase in ATP release within 20 seconds of acoustic exposure. A bench-top lysing system required 15-20 minutes operating up to 58 Watts to achieve the same level of cell lysis. We demonstrate that active mixing on the cartridge was critical to maximize binding and release of nucleic acid to the magnetic beads. Using a sol-gel silica bead matrix filled microchannel the extraction efficacy was 40%. The cartridge based magnetic bead system had an extraction efficiency of 19.2%. For an electric field based method that used Nafion films, a nucleic acid extraction efficiency of 66.3 % was achieved at 6 volts DC. For the flow rates we tested (10-50 {micro}L/min), the nucleic acid extraction

  2. Extending EV Range with Direct Methanol Fuel Cells

    OpenAIRE

    Steckmann, Kai

    2009-01-01

    Electric cars are the vehicles of the future, and there is a proven hybrid system for extending their mileage. Direct methanol fuel cells (DMFCs) provide safe, lightweight, onboard battery charging that can free car owners from worry about running out of power. The hybrid system includes a DMFC fuel cell, fuel cell cartridge and electric vehicle batteries. The fuel cell operates almost silently with virtually no exhaust, it is immune to extreme weather and the convenient fuel cartridges featu...

  3. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    OpenAIRE

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2015-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtai...

  4. Development of ballistics identification—from image comparison to topography measurement in surface metrology

    International Nuclear Information System (INIS)

    Song, J; Chu, W; Vorburger, T V; Thompson, R; Renegar, T B; Zheng, A; Yen, J; Silver, R; Ols, M

    2012-01-01

    Fired bullets and ejected cartridge cases have unique ballistics signatures left by the firearm. By analyzing the ballistics signatures, forensic examiners can trace these bullets and cartridge cases to the firearm used in a crime scene. Current automated ballistics identification systems are primarily based on image comparisons using optical microscopy. The correlation accuracy depends on image quality which is largely affected by lighting conditions. Because ballistics signatures are geometrical micro-topographies by nature, direct measurement and correlation of the surface topography is being investigated for ballistics identification. A Two-dimensional and Three-dimensional Topography Measurement and Correlation System was developed at the National Institute of Standards and Technology for certification of Standard Reference Material 2460/2461 bullets and cartridge cases. Based on this system, a prototype system for bullet signature measurement and correlation has been developed for bullet signature identifications, and has demonstrated superior correlation results. (paper)

  5. Development and validation of an automated unit for the extraction of radiocaesium from seawater

    International Nuclear Information System (INIS)

    Bokor, Ilonka; Sdraulig, Sandra; Jenkinson, Peter; Madamperuma, Janaka; Martin, Paul

    2016-01-01

    An automated unit was developed for the in-situ extraction of radiocaesium ( 137 Cs and 134 Cs) from large volumes of seawater to achieve very low detection limits. The unit was designed for monitoring of Australian ocean and coastal waters, including at ports visited by nuclear-powered warships. The unit is housed within a robust case, and is easily transported and operated. It contains four filter cartridges connected in series. The first two cartridges are used to remove any suspended material that may be present in the seawater, while the last two cartridges are coated with potassium copper hexacyanoferrate for caesium extraction. Once the extraction is completed the coated cartridges are ashed. The ash is transferred to a small petri dish for counting of 137 Cs and 134 Cs by high resolution gamma spectrometry for a minimum of 24 h. The extraction method was validated for the following criteria: selectivity, trueness, precision, linearity, limit of detection and traceability. The validation showed the unit to be fit for purpose with the method capable of achieving low detection limits required for environmental samples. The results for the environmental measurements in Australian seawater correlate well with those reported in the Worldwide Marine Radioactivity Study (WOMARS). The cost of preparation and running the system is low and waste generation is minimal. - Highlights: • Automated unit for in-situ extraction of 137 Cs and 134 Cs from 1000 L of seawater. • Unit is robust, and easily transported and operated. • Cs extraction uses cartridges coated with potassium copper hexacyanoferrate. • Validated for selectivity, trueness, precision, linearity, LOD and traceability. • System fit for purpose for monitoring of Australian coastal and ocean waters.

  6. New chromatographic systems for the quality control determination of 99Tcm-tetrofosmin

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of 99 Tc m -tetrofosmin requires the use of a volatile solvent system on silica gel impregnated thin layer chromatography strips, and is a time-consuming procedure (> 15 minutes). A rapid quality control procedure for this product has already been proposed which utilizes miniature Whatman 1 paper strips with ethyl acetate as the mobile phase, where 99 Tc m -tetrofosmin appears at the solvent front (R f 0.9). In our laboratory, this procedure was found to be unreliable, prompting us to develop two new and improved methods to successfully determine the % RCP of 99 Tc m -tetrofosmin. These include: (1) an Amprep anion exchange cartridge with absolute ethanol as the mobile phase; and (2) a miniature Whatman 17 strip with ethyl acetate:acetone [1:9] as the mobile phase. 99 Tc m -tetrofosmin elutes with the solvent, and 99 Tc m O 2 plus 99 Tc m O 4 -remain on the cartridge for the cartridge method. 99 Tc m -tetrofosmin moves with the solvent front (Rf 0.8) and the other 99 Tc m -impurities remain at the origin for the Whatman paper method. The % RCP of 99 Tc m -tetrofosmin (n = 8) by the manufacturer's method was 96.5 ± 1.5%, as compared to the cartridge method (98.0 ± 0.9%) and Whatman paper method (97.3 ± 0.9%) at 0-2 h post-reconstitution. The quality control determinations gave a result in 3 or 5 min for the cartridge or Whatman paper methods respectively. These methods can be used successfully in a dose calibrator for counting, particularly if the total counts are > 1.5 MBq. These new methods were found to be highly reproducible, convenient and rapid for the routine analysis of 99 Tc m -tetrofosmin preparations

  7. Effects of carprofen, meloxicam and deracoxib on platelet function in dogs.

    Science.gov (United States)

    Mullins, Kathleen B; Thomason, John M; Lunsford, Kari V; Pinchuk, Lesya M; Langston, Vernon C; Wills, Robert W; McLaughlin, Ronald M; Mackin, Andrew J

    2012-03-01

    To determine effects of anti-inflammatory doses of COX-2 selective NSAIDs carprofen, meloxicam, and deracoxib on platelet function in dogs and urine 11-dehydro-thromboxane B2. Randomized, blocked, crossover design with a 14-day washout period. Healthy intact female Walker Hounds aged 1-6 years and weighing 20.5-24.2 kg. Dogs were given NSAIDs for 7 days at recommended doses: carprofen (2.2 mg kg(-1), PO, every 12 hours), carprofen (4.4 mg kg(-1), PO, every 24 hours), meloxicam (0.2 mg kg(-1), PO, on the 1st day then 0.1 mg kg(-1), PO, every 24 hours), and deracoxib (2 mg kg(-1), PO, every 24 hours). Collagen/epinephrine and collagen/ADP PFA-100 cartridges were used to evaluate platelet function before and during and every other day after administration of each drug. Urine 11-dehydro-thromboxane B(2) was also measured before and during administration of each drug. All NSAIDs significantly prolonged PFA-100 closure times when measured with collagen/epinephrine cartridges, but not with collagen/ADP cartridges. The average duration from drug cessation until return of closure times (collagen/epinephrine cartridges) to baseline values was 11.6, 10.6, 11 and 10.6 days for carprofen (2.2 mg kg(-1) every 12 hours), carprofen (4.4 mg kg(-1) every 24 hours), meloxicam and deracoxib, respectively. Oral administration of some COX-2 selective NSAIDs causes detectable alterations in platelet function in dogs. As in humans, PFA-100 collagen/ADP cartridges do not reliably detect COX-mediated platelet dysfunction in dogs. Individual assessment of platelet function is advised when administering these drugs prior to surgery, particularly in the presence of other risk factors for bleeding. © 2011 The Authors. Veterinary Anaesthesia and Analgesia. © 2011 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

  8. Multi-class multi-residue analysis of veterinary drugs in meat using enhanced matrix removal lipid cleanup and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhao, Limian; Lucas, Derick; Long, David; Richter, Bruce; Stevens, Joan

    2018-05-11

    This study presents the development and validation of a quantitation method for the analysis of multi-class, multi-residue veterinary drugs using lipid removal cleanup cartridges, enhanced matrix removal lipid (EMR-Lipid), for different meat matrices by liquid chromatography tandem mass spectrometry detection. Meat samples were extracted using a two-step solid-liquid extraction followed by pass-through sample cleanup. The method was optimized based on the buffer and solvent composition, solvent additive additions, and EMR-Lipid cartridge cleanup. The developed method was then validated in five meat matrices, porcine muscle, bovine muscle, bovine liver, bovine kidney and chicken liver to evaluate the method performance characteristics, such as absolute recoveries and precision at three spiking levels, calibration curve linearity, limit of quantitation (LOQ) and matrix effect. The results showed that >90% of veterinary drug analytes achieved satisfactory recovery results of 60-120%. Over 97% analytes achieved excellent reproducibility results (relative standard deviation (RSD) meat matrices. The matrix co-extractive removal efficiency by weight provided by EMR-lipid cartridge cleanup was 42-58% in samples. The post column infusion study showed that the matrix ion suppression was reduced for samples with the EMR-Lipid cartridge cleanup. The reduced matrix ion suppression effect was also confirmed with 30%) for all tested veterinary drugs in all of meat matrices. The results showed that the two-step solid-liquid extraction provides efficient extraction for the entire spectrum of veterinary drugs, including the difficult classes such as tetracyclines, beta-lactams etc. EMR-Lipid cartridges after extraction provided efficient sample cleanup with easy streamlined protocol and minimal impacts on analytes recovery, improving method reliability and consistency. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Simultaneous quantification of dissolved organic carbon fractions and copper complexation using solid-phase extraction

    International Nuclear Information System (INIS)

    McElmurry, Shawn P.; Long, David T.; Voice, Thomas C.

    2010-01-01

    Trace metal cycling in natural waters is highly influenced by the amount and type of dissolved organic C (DOC). Although determining individual species of DOC is unrealistic, there has been success in classifying DOC by determining operationally defined fractions. However, current fractionation schemes do not allow for the simultaneous quantification of associated trace metals. Using operational classifications, a scheme was developed to fractionate DOC based on a set of seven solid-phase extraction (SPE) cartridges. The cartridges isolated fractions based on a range of specific mechanisms thought to be responsible for DOC aggregation in solution, as well as molecular weight. The method was evaluated to determine if it can identify differences in DOC characteristics, including differences in Cu-DOC complexation. Results are that: (1) cartridge blanks were low for both DOC and Cu, (2) differences are observed in the distribution of DOC amongst the fractions from various sources that are consistent with what is known about the DOC materials and the mechanisms operative for each cartridge, (3) when present as a free cation, Cu was not retained by non-cationic cartridges allowing the method to be used to assess Cu binding, (4) the capability of the method to provide quantitative assessment of Cu-DOC complexation was demonstrated for a variety of DOC standards, (5) Cu was found to preferentially bind with high molecular weight fractions of DOC, and (6) estimated partitioning coefficients and conditional binding constants for Cu were similar to those reported elsewhere. The method developed describes DOC characteristics based on specific bonding mechanisms (hydrogen, donor-acceptor, London dispersion, and ionic bonding) while simultaneously quantifying Cu-DOC complexation. The method provides researchers a means of describing not only the extent of DOC complexation but also how that complex will be behave in natural waters.

  10. Precision of quantitative computed tomography texture analysis using image filtering: A phantom study for scanner variability.

    Science.gov (United States)

    Yasaka, Koichiro; Akai, Hiroyuki; Mackin, Dennis; Court, Laurence; Moros, Eduardo; Ohtomo, Kuni; Kiryu, Shigeru

    2017-05-01

    Quantitative computed tomography (CT) texture analyses for images with and without filtration are gaining attention to capture the heterogeneity of tumors. The aim of this study was to investigate how quantitative texture parameters using image filtering vary among different computed tomography (CT) scanners using a phantom developed for radiomics studies.A phantom, consisting of 10 different cartridges with various textures, was scanned under 6 different scanning protocols using four CT scanners from four different vendors. CT texture analyses were performed for both unfiltered images and filtered images (using a Laplacian of Gaussian spatial band-pass filter) featuring fine, medium, and coarse textures. Forty-five regions of interest were placed for each cartridge (x) in a specific scan image set (y), and the average of the texture values (T(x,y)) was calculated. The interquartile range (IQR) of T(x,y) among the 6 scans was calculated for a specific cartridge (IQR(x)), while the IQR of T(x,y) among the 10 cartridges was calculated for a specific scan (IQR(y)), and the median IQR(y) was then calculated for the 6 scans (as the control IQR, IQRc). The median of their quotient (IQR(x)/IQRc) among the 10 cartridges was defined as the variability index (VI).The VI was relatively small for the mean in unfiltered images (0.011) and for standard deviation (0.020-0.044) and entropy (0.040-0.044) in filtered images. Skewness and kurtosis in filtered images featuring medium and coarse textures were relatively variable across different CT scanners, with VIs of 0.638-0.692 and 0.430-0.437, respectively.Various quantitative CT texture parameters are robust and variable among different scanners, and the behavior of these parameters should be taken into consideration.

  11. Does the combination of 3% mepivacaine plain plus 2% lidocaine with epinephrine improve anesthesia and reduce the pain of anesthetic injection for the inferior alveolar nerve block? A prospective, randomized, double-blind study.

    Science.gov (United States)

    Lammers, Emily; Nusstein, John; Reader, Al; Drum, Melissa; Beck, Mike; Fowler, Sara

    2014-09-01

    In theory, using 3% mepivacaine initially for an inferior alveolar nerve (IAN) block would decrease the pain of injection, provide faster onset, and increase anesthetic success. The purpose of this prospective, randomized, double-blind study was to compare the degree of pulpal anesthesia obtained with a combination of 3% mepivacaine/2% lidocaine (1:100,000 epinephrine) versus a combination of 2% lidocaine (1:100,000 epinephrine)/2% lidocaine (1:100,000 epinephrine) in IAN blocks. Injection pain was also studied. One hundred asymptomatic subjects were randomly given a combination of a 1-cartridge volume of 3% mepivacaine plus a 1-cartridge volume of 2% lidocaine with 1:100,000 epinephrine and a combination of a 1-cartridge volume of 2% lidocaine with 1:100,000 epinephrine plus a 1-cartridge volume of 2% lidocaine with 1:100,000 epinephrine for the IAN block at 2 separate appointments. Subjects rated the pain of injection. The molars, premolars, and incisors were tested with an electric pulp tester in 4-minute cycles for 60 minutes. Anesthetic success was defined as the subject achieving 2 consecutive 80 readings within 15 minutes after completion of the IAN blocks and sustaining the 80 reading for 60 minutes. Success was not significantly different (P > .05) between the 2 combinations. No statistical differences in injection pain or onset times were found. The combination of 3% mepivacaine plus 2% lidocaine with 1:100,000 epinephrine was equivalent to the combination of 2 cartridges of 2% lidocaine with 1:100,000 epinephrine in terms of injection pain, onset time, and pulpal anesthetic success for the IAN block. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. The Use of a Mechanical Non-Penetrating Captive Bolt Device for the Euthanasia of Neonate Lambs.

    Science.gov (United States)

    Grist, Andrew; Lines, Jeff A; Knowles, Toby G; Mason, Charles W; Wotton, Stephen B

    2018-04-02

    A non-penetrating captive bolt device, powered by a 1-grain 0.22″ cartridge delivering a calculated kinetic energy of 47 Joules was tested as a euthanasia method on 200 neonate lambs (Ovis aries) of 4.464 kg (SD (Standard deviation) ± 1.056) mean dead weight, to assess effectiveness and shot position. Every lamb (n = 200) was effectively stunned when the weapon was applied powered by a brown, 1-grain cartridge but 10/200 (5%) of the lambs displayed rhythmic or agonal breathing and were subsequently euthanased using euthatal (Merial, UK, GTIN: 03661103015550). Evaluation of the method was conducted using behavioural indicators of brain dysfunction followed by post-mortem examination of the heads. A second trial was conducted using a higher velocity 1.25-grain cartridge and a specific shot position on 48 lambs (mean dead weight = 6.21 kg, SD ± 1.24) averaging 5 days old. One hundred percent of the lambs in the second trial were immediately stun-killed. Given this complete kill rate and the sample size of the study, the study provides a statistical 95% confidence interval of 92.6% to 100%. The use of the Accles & Shelvoke “CASH” Small Animal Tool (Birmingham, UK) can therefore be recommended for the euthanasia of neonate lambs with a 1.25-grain cartridge and a specific shooting position.

  13. The Use of a Mechanical Non-Penetrating Captive Bolt Device for the Euthanasia of Neonate Lambs

    Directory of Open Access Journals (Sweden)

    Andrew Grist

    2018-04-01

    Full Text Available A non-penetrating captive bolt device, powered by a 1-grain 0.22″ cartridge delivering a calculated kinetic energy of 47 Joules was tested as a euthanasia method on 200 neonate lambs (Ovis aries of 4.464 kg (SD (Standard deviation ± 1.056 mean dead weight, to assess effectiveness and shot position. Every lamb (n = 200 was effectively stunned when the weapon was applied powered by a brown, 1-grain cartridge but 10/200 (5% of the lambs displayed rhythmic or agonal breathing and were subsequently euthanased using euthatal (Merial, UK, GTIN: 03661103015550. Evaluation of the method was conducted using behavioural indicators of brain dysfunction followed by post-mortem examination of the heads. A second trial was conducted using a higher velocity 1.25-grain cartridge and a specific shot position on 48 lambs (mean dead weight = 6.21 kg, SD ± 1.24 averaging 5 days old. One hundred percent of the lambs in the second trial were immediately stun-killed. Given this complete kill rate and the sample size of the study, the study provides a statistical 95% confidence interval of 92.6% to 100%. The use of the Accles & Shelvoke “CASH” Small Animal Tool (Birmingham, UK can therefore be recommended for the euthanasia of neonate lambs with a 1.25-grain cartridge and a specific shooting position.

  14. Determination of extra and intracellular content from some lytic enzymes related with carnation (Dianthus caryophyllus L. root cell wall

    Directory of Open Access Journals (Sweden)

    Sixta Tulia Martínez Peralta

    2016-11-01

    Full Text Available The presence of some enzymes related to cell wall (polygalacturonase, the pectate lyase, protease and xylanase in carnation (Dianthus caryophyllus L. roots as well as the activity levels were determined. These levels were analyzed in different cellular places: the intercellular fluid that is part of apoplast, the symplast, and the total level (apoplast and symplast in carnation roots. Two methods were tested to extract the intercellular fluid. To obtain the intracellular content (symplast and total extract (apoplast+symplast, three methods were tested, using as extracting solution  i phosphate buffer, ii phosphate buffer + PVPP,  iii before the extraction with phosphate buffer, the carnation roots were washed with acetone.  The results showed the effect of different extracting solutions in the enzymatic activities and in the protein content. A new only one step method is proposed to extract the four enzymes and make the comparative analysis of enzymatic activity.

  15. Removal of fumonisin B1 and B2 from model solutions and red wine using polymeric substances.

    Science.gov (United States)

    Carrasco-Sánchez, Verónica; Kreitman, Gal Y; Folch-Cano, Christian; Elias, Ryan J; Laurie, V Felipe

    2017-06-01

    Fumonisins are a group of mycotoxins found in various foods whose consumption is known to be harmful for human health. In this study, we evaluated the ability of three polymers (Polyvinylpolypyrrolidone, PVPP; a resin of N-vinyl-2-pyrrolidinone with ethylene glycol dimethacrylate and triallyl isocyanurate, PVP-DEGMA-TAIC; and poly(acrylamide-co-ethylene glycol-dimethacrylate), PA-EGDMA) to remove fumonisin B 1 (FB1) and fumonisin B 2 (FB2) from model solutions and red wine. Various polymer concentrations (1, 5 and 10mgmL -1 ) and contact times (2, 8 and 24h) were tested, with all polymers exhibiting fumonisin removal capacities (monitored by LC-MS). The impact of all polymers on polyphenol removal was also assessed. PA-EGDMA showed to be the most promising polymer, removing 71% and 95% of FB 1 , and FB 2 , respectively, with only a 22.2% reduction in total phenolics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. An in-line clean system for the solid-phase extraction of emerging contaminants in natural waters

    OpenAIRE

    Sodré, Fernando F.; Locatelli, Marco Antonio F.; Jardim, Wilson F.

    2010-01-01

    A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus i...

  17. Miniature acoustic wave lysis system and uses thereof

    Science.gov (United States)

    Branch, Darren W.; Vreeland, Erika Cooley; Smith, Gennifer Tanabe

    2016-12-06

    The present invention relates to an acoustic lysis system including a disposable cartridge that can be reversibly coupled to a platform having a small, high-frequency piezoelectric transducer array. In particular, the system releases viable DNA, RNA, and proteins from human or bacterial cells, without chemicals or additional processing, to enable high-speed sample preparation for clinical point-of-care medical diagnostics and use with nano/microfluidic cartridges. Also described herein are methods of making and using the system of the invention.

  18. Sistema limpo em linha para extração em fase sólida de contaminantes emergentes em águas naturais

    OpenAIRE

    Sodré,Fernando F.; Locatelli,Marco Antonio F.; Jardim,Wilson F.

    2010-01-01

    A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus i...

  19. Development of SPE for recovery of polysaccharides and its application to the determination of monosaccharides composition of the polysaccharide sample of a lactobacillus KLB 58.

    Science.gov (United States)

    Baik, Yoon Suk; Cheong, Won Jo

    2007-07-01

    A new SPE cartridge has been prepared in this study to purify polysaccharides of high molecular weights. A porous nonpolar styrene-divinylbenzene copolymer phase (Hamilton PRP-1) was used to make the new cartridge. The cartridge was conditioned with methanol, water, and ACN in sequence, and the sample dissolved in a small amount of water was loaded. Impurities of low molecular weights were removed first by elution of 80:20 or 90:10 v/v% ACN/water, and polysaccharides were quantitatively recovered by elution of 50:50 v/v% ACN/water or pure water. The recovery of pure dextran 10000 was 90-95%. The SPE method was applied to purification of the polysaccharide sample of KLB58, a new lactobacillus discovered in Korea. The purified KLB 58 sample (weight recovery after SPE purification; 60%) was hydrolyzed for analysis of composition of monosaccharides. The hydrolysate was found to be composed primarily of fructose, glucose, galactose, rhamnose, mannose with small amounts of fucose and ribose.

  20. Solid-phase extraction of carotenoids.

    Science.gov (United States)

    Shen, Yao; Hu, Yumin; Huang, Ke; Yin, Shi'an; Chen, Bo; Yao, Shouzhuo

    2009-07-24

    In this work, solid-phase extraction (SPE) trapping performance of lutein and beta-carotene, which were used as the model molecules of carotenoids, was investigated. The absorption, elution, and enrichment of carotenoids on SPE cartridges with four different sorbents, i.e. C(30), C(18), diol, and silica, were compared respectively with the help of frontal analysis technique. The high retentions of both lutein and beta-carotene were achieved on the C(18) and C(30) cartridges. The diol and silica cartridges only had good retention for lutein. The optimized SPE method for sample pretreatment for the carotenoids analysis was obtained after the investigation of trapping performance. The method was applied successfully to the analysis of biological sample, i.e. serum and human breast milk. The recovery, accuracy, and precision of SPE method comparing with those of traditional liquid-liquid extraction (LLE) method for the sample pretreatment for the analysis of carotenoids owned a number of advantages such as rapid, no chloroform used, and accurate versus LLE.

  1. Recirculating electric air filter for use in confined spaces

    International Nuclear Information System (INIS)

    Bergman, W.; Biermann, A.; Kuhl, W.

    1985-01-01

    We have developed recirculating electric air filters for use in confined spaces where the existing ventilation system is not adequate for removing suspended particles. Two experimental filters were built and evaluated, both of which consisted of a cylindrical cartridge filter fitted over an air blower. In one design the cylindrical cartridge is a disposable unit with the electrodes and filter medium built as an integrated unit. The second design has a cylindrical cartridge that can be easily disassembled to allow replacement of the filter medium. Both designs were evaluated in a 354-ft 3 test cell using NaCl aerosols. The second design was installed and evaluated in a chamber where highly radioactive 238 PuO 2 powder is formed into pellets. We have derived equations that describe the theory of recirculating air filters. The predicted performance compares well with experimental measurements under controlled conditions. 2 refs., 7 figs., 1 tab. (DT)

  2. Autonomous detection of ISO fade point with color laser printers

    Science.gov (United States)

    Yan, Ni; Maggard, Eric; Fothergill, Roberta; Jessome, Renee J.; Allebach, Jan P.

    2015-01-01

    Image quality assessment is a very important field in image processing. Human observation is slow and subjective, it also requires strict environment setup for the psychological test 1. Thus developing algorithms to match desired human experiments is always in need. Many studies have focused on detecting the fading phenomenon after the materials are printed, that is to monitor the persistence of the color ink 2-4. However, fading is also a common artifact produced by printing systems when the cartridges run low. We want to develop an automatic system to monitor cartridge life and report fading defects when they appear. In this paper, we first describe a psychological experiment that studies the human perspective on printed fading pages. Then we propose an algorithm based on Color Space Projection and K-means clustering to predict the visibility of fading defects. At last, we integrate the psychological experiment result with our algorithm to give a machine learning tool that monitors cartridge life.

  3. Use of a new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.R. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.; Univ. of Bonn

    1998-03-01

    In this paper the authors describe the first application of a simple and inexpensive post elution tandem cation-anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine type (QMA SepPak trademark) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator

  4. Use of new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.

    1998-01-01

    In this paper we describe the first application of our simple and inexpensive post-elution tandem cation/anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical-scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine-type (QMA SepPak TM ) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator. (author)

  5. Microfluidic system for the identification of bacterial pathogens causing urinary tract infections

    Science.gov (United States)

    Becker, Holger; Hlawatsch, Nadine; Haraldsson, Tommy; van der Wijngaart, Wouter; Lind, Anders; Malhotra-Kumar, Surbi; Turlej-Rogacka, Agata; Goossens, Herman

    2015-03-01

    Urinary tract infections (UTIs) are among the most common bacterial infections and pose a significant healthcare burden. The growing trend in antibiotic resistance makes it mandatory to develop diagnostic kits which allow not only the determination of a pathogen but also the antibiotic resistances. We have developed a microfluidic cartridge which takes a direct urine sample, extracts the DNA, performs an amplification using batch-PCR and flows the sample over a microarray which is printed into a microchannel for fluorescence detection. The cartridge is injection-molded out of COP and contains a set of two-component injection-molded rotary valves to switch between input and to isolate the PCR chamber during thermocycling. The hybridization probes were spotted directly onto a functionalized section of the outlet microchannel. We have been able to successfully perform PCR of E.coli in urine in this chip and perform a fluorescence detection of PCR products. An upgraded design of the cartridge contains the buffers and reagents in blisters stored on the chip.

  6. The Kansas State University revolving sputter source

    International Nuclear Information System (INIS)

    Tipping, T.N.

    1989-01-01

    It has been that the perfect ion source is one which runs in a very stable mode, runs continuously, and has the ability to change ion species without sacrificing the previous two requirements. This paper presents an approximation to the perfect ion source, the KSU Revolving Sputter Source. The source consists of an Aarhus-geometry sputter source with the addition of a rotating wheel which holds eight sputter cathodes. The wheel consists of a front plate with eight fixed Macor insulators and a back plate with eight Macor insulators held in place by the tension of eight springs. The cathode assembly consists of a copper cartridge with a threaded rod on one end and a sputter cathode with a threaded hole on the back. The cathode is screwed onto the cartridge and the whole assembly may be loaded into the wheel. A small spring on the side of the cartridge holds the assembly in the wheel

  7. Bubble formation occurs in insulin pumps in response to changes in ambient temperature and atmospheric pressure but not as a result of vibration.

    Science.gov (United States)

    Lopez, Prudence E; King, Bruce R; Goss, Peter W; Chockalingam, Ganesh

    2014-01-01

    Bubble formation in insulin pump giving sets is a common problem. We studied change in temperature, change in atmospheric pressure, and vibration as potential mechanisms of bubble formation. 5 Animas 2020 pumps with 2 mL cartridges and Inset II infusion systems, 5 Medtronic Paradigm pumps with 1.8 mL cartridge and Quickset and 3 Roche Accu-chek pumps with 3.15 mL cartridges were used. Temperature study: insulin pumps were exposed to a temperature change from 4°C to 37°C. Pressure study: insulin pumps were taken to an altitude of 300 m. Vibration study: insulin pumps were vigorously shaken. All were observed for bubble formation. Bubble formation was observed with changes in temperature and atmospheric pressure. Bubble formation did not occur with vibration. Changes in insulin temperature and atmospheric pressure are common and may result in bubble formation. Vibration may distribute bubbles but does not cause bubble formation.

  8. The active personnel dosimeter---APFEL enterprises superheated drop detector

    International Nuclear Information System (INIS)

    Ipe, N.E.; Donahue, R.J.; Busick, D.D.

    1991-03-01

    The Active Personnel Dosimeter (APD) provides a digital readout of events caused by neutrons interacting with superheated liquid droplets. The droplets are suspended in a gel held in a replaceable cartridge. Upon neutron interaction, the superheated droplet vaporizes, forming a bubble. The sound produced in this process is recorded by transducers that sense the accompanying pressure pulse. The APD electronically discriminates against spurious noise and vibration. Studies with the production prototype APDs indicate that the detector response is linear up to about 0.40 mSv, with large variations sometimes from predicted values and between cartridges at higher dose equivalents. The response to standard neutron sources (bare 252 Cf, PuBe, PuB, PuF, PuLi) is reported and compared with the expected response. Unirradiated cartridges self-nucleate when heated to temperatures of 46 degrees C. The APD is insensitive to low-energy photons but responds to high-energy photons and electrons. 8 refs., 2 figs., 3 tabs

  9. Development of a calibration system for airborne "1"3"1I monitoring devices

    International Nuclear Information System (INIS)

    Zhao, C.; Tang, F.; He, L.; Xu, Y.; Lu, X.

    2016-01-01

    A prototype calibration system for airborne "1"3"1I monitoring devices was developed at the Shanghai Institute of Measurement and Testing Technology (SIMT). This system consists of a gaseous "1"3"1I_2 generator, an airborne storage chamber, an airborne iodine sampler, and an HPGe spectrometer. With this system, "1"3"1I reference samples in the form of charcoal filters and charcoal cartridges, with activities ranging from 100 to 10,000 Bq, were produced with overall relative standard uncertainties of 2.8% (for filter samples) and 3.5% (for cartridge samples); the activities range could be extended according to need. - Highlights: • Original calibration system for airborne "1"3"1I monitoring devices was developed. • Two types of "1"3"1I reference samples was prepared. • The activity of the produced "1"3"1I reference sample could be easily controlled. • The influence of uneven distribution of "1"3"1I in cartridge samples was considered.

  10. Deformations of fuel elements under irradiation (Examination of the 2000 C set, investigation of the Cottrell effect)

    International Nuclear Information System (INIS)

    Thome, P.; Allain, C.

    1959-04-01

    The authors report visual and radiographic examinations of cartridges of the 2000 C solution C in order to study the influence of the combustion rate on deformations of these cartridges which spent about a year in an atomic pile. The deformation measurements are interpreted in terms of creep phenomena (Cottrell effect), of surface condition, and buckling. The authors discuss the validity of mechanical tests, the distinction between creep and flow, the deformation of fuel assemblies, the validity of thermal cycle tests, the effects of alloy compositions

  11. Human Metabolite Lamotrigine-N(2)-glucuronide Is the Principal Source of Lamotrigine-Derived Compounds in Wastewater Treatment Plants and Surface Water.

    Science.gov (United States)

    Zonja, Bozo; Pérez, Sandra; Barceló, Damià

    2016-01-05

    Wastewater and surface water samples, extracted with four solid-phase extraction cartridges of different chemistries, were suspect-screened for the anticonvulsant lamotrigine (LMG), its metabolites, and related compounds. LMG, three human metabolites, and a LMG synthetic impurity (OXO-LMG) were detected. Preliminary results showed significantly higher concentrations of OXO-LMG in wastewater effluent, suggesting its formation in the wastewater treatment plants (WWTPs). However, biodegradation experiments with activated sludge demonstrated that LMG is resistant to degradation and that its human metabolite lamotrigine-N(2)-glucuronide (LMG-N2-G) is the actual source of OXO-LMG in WWTPs. In batch reactors, LMG-N2-G was transformed, following pseudo-first-order kinetics to OXO-LMG and LMG, but kinetic experiments suggested an incomplete mass balance. A fragment ion search applied to batch-reactor and environmental samples revealed another transformation product (TP), formed by LMG-N2-G oxidation, which was identified by high-resolution mass spectrometry. Accounting for all TPs detected, a total mass balance at two concentration levels in batch reactors was closed at 86% and 102%, respectively. In three WWTPs, the total mass balance of LMG-N2-G ranged from 71 to 102%. Finally, LMG-N2-G and its TPs were detected in surface water samples with median concentration ranges of 23-139 ng L(-1). The results of this study suggest that glucuronides of pharmaceuticals might also be sources of yet undiscovered, but environmentally relevant, transformation products.

  12. Novel nanoporous sorbent for solid-phase extraction in petroleum fingerprinting

    Science.gov (United States)

    Alayande, S. Oluwagbemiga; Hlengilizwe, Nyoni; Dare, E. Olugbenga; Msagati, Titus A. M.; Akinlabi, A. Kehinde; Aiyedun, P. O.

    2016-04-01

    Sample preparation is crucial in the analysis of petroleum and its derivatives. In this study, developing affordable sorbent for petroleum fingerprinting analysis using polymer waste such expanded polystyrene was explored. The potential of electrospun expanded polystyrene (EPS) as a sorbent for the solid-phase extraction (SPE) technique was investigated, and its efficiency was compared with commercial cartridges such as alumina, silica and alumina/silica hybrid commercial for petroleum fingerprinting analysis. The chromatograms showed that the packed electrospun EPS fibre demonstrated excellent properties for SPE applications relative to the hybrid cartridges.

  13. Determination of carbonyl compounds in air by HPLC

    International Nuclear Information System (INIS)

    Garcia, S.; Perez, R.M.; Campos, A.; Gonzalez, D.

    1995-09-01

    A method for the determination of seven carbonyl compounds in air is presented. The procedure involve sampling of air by a Sep-Pak cartridge impregnated with 2,4-dinitrophenylhydrazine. Elution was done with 3 mL of acetonitrile and the eluate was diluted to 5 mL. The analysis was done by HPLC with UV detection and external standard method quantification. It has been achieved relative standard deviations about 5% and detection limits of 80 ng/cartridge for formaldehyde, acetaldehyde and acetone+acrolein. Three different types of samples (rural, urban, petrol emission) were successfully analyzed

  14. Identification of atractyloside by LC-ESI-MS in alleged herbal poisoning

    CSIR Research Space (South Africa)

    Steenkamp, PA

    2006-11-01

    Full Text Available , approximately 3000 species are used as medicines, and of these, some 350 species are commonly used and traded medicinal plants [3,11]. One of these more commonly used plants is Callilepis laureola DC. (Asteraceae), also called ??Ox-eye daisy?? or ??Wildemagriet... by hand and drawn through the cartridges at approximately 1 ml/min by applying a mild vacuum. The cartridges were washed with 3 ml extracting buffer and dried under vacuum for 10 min. They were then eluted with 3 ml methanol, 3 ml acidic methanol (10 ml...

  15. Bottom loaded filter for radioactive liquids

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1983-01-01

    This invention relates to equipment for filtering liquids and more particularly to filter assemblies for use with radioactive by-products of nuclear power plants. The invention provides a compact, bottom-loaded filter assembly that can be quickly and safely loaded and unloaded without the use of complex remote equipment. The assembly is integrally shielded and does not require external shielding. The closure hatch may be automatically aligned to facilitate quick sealing attachment after replacement of the filter cartridge, and the filter cartridge may be automatically positioned within the filter housing during the replacement operation

  16. Planning of Eka Hospital Pekanbaru wastewater recycling facility

    Science.gov (United States)

    Jecky, A.; Andrio, D.; Sasmita, A.

    2018-04-01

    The Ministry of Public Works No. 06 2011 required the large scale of water to conserve the water resource, Eka Hospital Pekanbaru have to improve the sewage treatment plant through the wastewater recycling. The effluent from the plant can be used to landscape gardening and non-potable activities. The wastewater recycling design was done by analyzing the existing condition of thesewage treatment plant, determine the effluent quality standards for wastewater recycling, selected of alternative technology and processing, design the treatment unit and analyze the economic aspects. The design of recycling facility by using of combination cartridge filters processing, ultrafiltration membranes, and desinfection by chlorination. The wastewater recycling capacity approximately of 75 m3/day or 75% of the STP effluent. The estimated costs for installation of wastewater recycling and operation and maintenance per month are Rp 111,708,000 and Rp 2,498,000 respectively.

  17. Preparation and use of maize tassels' activated carbon for the adsorption of phenolic compounds in environmental waste water samples.

    Science.gov (United States)

    Olorundare, O F; Msagati, T A M; Krause, R W M; Okonkwo, J O; Mamba, B B

    2015-04-01

    The determination and remediation of three phenolic compounds bisphenol A (BPA), ortho-nitrophenol (o-NTP), parachlorophenol (PCP) in wastewater is reported. The analysis of these molecules in wastewater was done using gas chromatography (GC) × GC time-of-flight mass spectrometry while activated carbon derived from maize tassel was used as an adsorbent. During the experimental procedures, the effect of various parameters such as initial concentration, pH of sample solution, eluent volume, and sample volume on the removal efficiency with respect to the three phenolic compounds was studied. The results showed that maize tassel produced activated carbon (MTAC) cartridge packed solid-phase extraction (SPE) system was able to remove the phenolic compounds effectively (90.84-98.49%, 80.75-97.11%, and 78.27-97.08% for BPA, o-NTP, and PCP, respectively). The MTAC cartridge packed SPE sorbent performance was compared to commercially produced C18 SPE cartridges and found to be comparable. All the parameters investigated were found to have a notable influence on the adsorption efficiency of the phenolic compounds from wastewaters at different magnitudes.

  18. Many More Bytes For Physics

    CERN Multimedia

    2001-01-01

    With experiments such as COMPASS and NA48 pouring out huge amounts of data (over 200TeraBytes this year), the issue of data storage has been one of the Information Technology division's most important concerns. What has been most challenging of late has been finding and developing a new location to house their rapidly expanding collection of STK tape robots.   Nigel Baddams, Anne Funken and Tony Cass outside CERN's new data-storage building. When the Computer Centre moved to building 513 in the early 1970s, a conveyor belt system was used to take tapes from the vault where they were stored up to the tape drives in the computer room so the precious data could be read and analysed by the waiting researchers. This conveyor belt system lasted until the late 1980s when IBM's new 3480 cartridges took over from the old open reel tapes. At first, these cartridges didn't hold much more data than the old tapes, but their shape and size meant that robots were soon developed to store the cartridges and move ...

  19. Control apparatus for radioactive contamination of the filtering device adapted on the protection apparatus of the respiratory tracts (1961); Appareil de controle de la contamination radioactive des dispositifs filtrants adaptes sur les appareils de protection des voies respiratoires (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Dujancourt, S; Roche, J [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires

    1961-07-01

    That apparatus allows to detect and localize the radioactive contamination of the mask cartridge, for alpha, beta and gamma radiations, concerning external contamination, and for beta and gamma radiations, concerning internal contamination. It consists of lead coffin, in which the cartridge is inserted for control. Halogen counters are in contact with it. Operation conditions (Geiger or proportional) and their position on regard to the cartridge are controlled from outside. A sealer counts the pulses, given by the different counters. (authors) [French] Cet appareil permet de detecter et de localiser la contamination radioactive de cartouches filtrantes de masques, en {alpha}, {beta} et {gamma}, en ce qui concerne la contamination exterieure, et en {beta} et {gamma} en ce qui concerne la contamination interieure. Il est constitue par un coffre en plomb dans lequel est introduite la cartouche a controler. Des compteurs halogenes sont au contact de celle-ci. Leur regime de fonctionnement (Geiger ou proportionnel) et leur position par rapport a la cartouche sont commandes de l'exterieur. Une echelle de comptage compte les impulsions donnees par les differents compteurs. (auteurs)

  20. Study of pneumatic hydropulse filter for feed clarification in reprocessing plant head-end

    International Nuclear Information System (INIS)

    Siddiqui, I.A.; Shah, B.V.; Salunke, S.U.; Kumar, S.V.

    1991-01-01

    A Pneumatic Hydropulse (PHP) Filter with sintered stainless steel cartridges was tested for suitability in reprocessing plant head-end filtration. The filter was tested with simulated slurry containing between 25 and 400 ppm of calcium carbonate particulates in the size ranges 45 to 53 micron and 53 to 75 micron at varying flow rates. Procedures were developed for dislodging the layer of solids on the cartidridges and regenerating the filter remotely. Application of 5.4 kg/cm 2 air to the dome of the filter during regenaration was found to be optimum for dislodging the particulate layer on the cartridges. No difficulties due to choking of the filter cartridges were experienced during operation and good regeneration by remote operation was possible. Approach velocity at the filter medium was about 6 cm/min. The efficiency of regeneration was better than 90%. Filtration efficiency was found to be better than 90%. Solid loading capacity was found to increase with increase of particle size and feed concentration. (author). 2 figs., 10 tabs

  1. Characterization of primary coolant purification system samples for assay of spent ion exchanger radionuclide inventor

    International Nuclear Information System (INIS)

    Sajin Prasad, S.; Pant, Amar; Sharma, Ranjit; Pal, Sanjit

    2018-01-01

    The primary coolant system water of a research reactor contains various fission and activation products and the water is circulated continuously through ion exchange resin cartridges, to reduce the radioactive ionic impurity present in it. The coolant purification system comprises of an ion exchange cooler, two micro filters, and a battery of six ion exchanger beds, associated valves, piping and instrumentation (Heavy water System Operating manual, 2014). The spent cartridge is finally disposed off as active solid waste which contains predominantly long lived fission and activation products. The heavy water coolant is also used to cool the structural assemblies after passing through primary heat exchanger and a metallic strainer, which accumulates the fission and activation products. When there is a reduction of coolant flow through these strainers, they are removed for cleaning and decontamination. This paper describes the characterization of ion exchange resin samples and liquid effluent generated during ultra sonic decontamination of strainer. The results obtained can be used as a methodology for the assay of the spent ion exchanger cartridges radionuclide inventory, during its disposal

  2. Of data and dust

    CERN Multimedia

    Stephanie Hills

    2016-01-01

    The traditional image of an archive is one of dusty old boxes, books and papers. When your archive is digital, dust spells disaster. An innovative environmental sensor designed and built by a CERN IT specialist has become an essential element in the Laboratory’s data-preservation strategy.   The novel air particle monitoring sensor designed by CERN's Julien Leduc. CERN’s archive holds more than 130 petabytes of data from past and present high-energy physics experiments. Some of it is 40 years old, most of it needs to be kept forever, and all of it is held on tape cartridges (over 20,000 of them). The cartridges are held inside tape libraries with robotic arms that load them into tape drives where they can be read and written. Tape cartridges have many advantages over other data storage media, notably cost and long-term reliability, but topping the list of drawbacks is their vulnerability to contamination from airborne dust particles; a tiny piece of g...

  3. Identificarea armelor de vânătoare lise în funcție de caracteristicile impactului dintre cuiul percutor și capsa de inițiere [ Identification of hunting firearms depending on the characteristics of the impact bolt and staple initiation

    Directory of Open Access Journals (Sweden)

    Lesenciuc I

    2016-08-01

    Full Text Available Hunting firearms with smoothbores use multiple missiles (buckshots or unique missiles (brenneke. As these types of guns have a smooth bore hole, no imprints can be spotted clearly on the missiles, so as to establish the certain type of gun which they belong to. Also, the cartridge cases can be reused, manufacturing manually the ammunition. In this case, it is needed a new primer, which is mounted on the back side of the cartridge case. In fact, the primer represents that part of the cartridge hit by the firing pin, which deforms it irreversibly. On the other hand, the design characteristics of each firearm brand differ from one manufacturer to another. For this reason, it was studied the dynamics of the impact between the firing pin and the primer, at three European firearms brands: IJ, Zastava, Sauer-Bereta. The study focused on the differences which may occur at the impact characteristics (forces, time, and which can lead at least to the identification on the firearm brand.

  4. Some methods of detection of atmospheric contamination by iodine 131

    International Nuclear Information System (INIS)

    Billard, Francois; Chevalier, Gerard; Gaillard, Pierre; Pradel, Jacques

    1964-01-01

    Due to the extensive use of iodine, risks of contamination by iodine 131 are increasing. Moreover, the increase of reactor power requires venting installations equipped with efficient safety filters which must be tested. The authors thus report the study of iodine trapping in filters, and its atmospheric detection and measurement. They report studies and achievements in the field of measurement of atmospheric pollution, and tests performed on iodine trapping by activated coals. After having outlined key qualities of an apparatus for atmospheric control, the authors indicate the various sampling methods. They discuss the method and calibration for the measurement of radioactivity of filters and coal which have trapped iodine 131. They discuss measurement sensitivity. They report how the efficiency of coals has been checked. They describe the experimental installation, and report the tests of some detectors of atmospheric contamination: sampling cartridges full of activated coal, gas mask cartridge, continuous control apparatus ('coffee machine' type), and detector of gaseous iodine. Appendices indicate the calculation of error on a cartridge counting rate, iodine generation methods (discontinuous method, continuous method) [fr

  5. Isolation of dissolved organic matter from permafrost soil and freshwater environments of the Kolyma River basin, east Siberia, for high resolution structural analysis

    Science.gov (United States)

    Dubinenkov, I. V.; Perminova, I. V.; Bulygina, E. B.; Holmes, R. M.; Davydov, S.; Mann, P. J.; Vonk, J.; Zimov, S. A.

    2010-12-01

    The Arctic and Subarctic ecosystems are known to be the most vulnerable with respect to climate change. Hence, research on carbon cycling in the Arctic region is very important for understanding the current climatic trends and their consequences. The Kolyma River watershed is one of the Arctic Ocean’s largest. It is dominated by continuous permafrost which is underlain with rich organic soils susceptible to increased fluvial transport. The thaw of permafrost enhanced due to global warming might provide additional large source of organic carbon to the Kolyma River and to the Arctic Ocean as a whole. For estimating the contribution of this source to the total pool of organic carbon, specific structural features of permafrost dissolved organic matter (DOM) as opposed to the waterborne DOM of the Kolyma River should be identified and monitored. The objective of this work was to isolate a representive set of the DOM samples from permafrost soil and freshwater environments of the Kolyma River basin suitable for further structural analysis using high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectroscopy (FTICR-MS) and 1H NMR spectroscopy. The isolation protocol of DOM used in this study has been developed by Dittmar et al, 2008 for sampling marine DOM for NMR studies. It is based on the solid phase extraction of DOM from seawater using PPL Varian Bond Elute cartridges Those cartridges were shown to possess the highest efficiency in DOM isolation from marine water. Prior to discharge through the cartridge, a water sample was filtered through 0.45 μm filter for separation of particulate matter and acidified to pH 2 using HCl. About 50mg of DOM could be sequestered from aqueous phase using one cartridge. Sorption extent was monitored by measurements of DOC concentration and UV-vis spectra at the inlet and outlet of the cartridge. It was determined that from 60 to 65% of the total DOC could be extracted from the tested samples of freshwater. As a result

  6. Matrix solid-phase dispersion on column clean-up/pre-concentration as a novel approach for fast isolation of abuse drugs from human hair.

    Science.gov (United States)

    Míguez-Framil, Martha; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Pilar; Alvarez-Freire, Iván; Tabernero, María Jesús; Bermejo, Ana María

    2010-10-08

    A simple and fast sample pre-treatment method based on matrix solid-phase dispersion (MSPD) for isolating cocaine, benzoylecgonine (BZE), codeine, morphine and 6-monoacethylmorphine (6-MAM) from human hair has been developed. The MSPD approach consisted of using alumina (1.80 g) as a dispersing agent and 0.6M hydrochloric acid (4 mL) as an extracting solvent. For a fixed hair sample mass of 0.050 g, the alumina mass to sample mass ratio obtained was 36. A previously conditioned Oasis HLB cartridge (2 mL methanol, plus 2 mL ultrapure water, plus 1 mL of 0.2M/0.2M sodium hydroxide/boric acid buffer solution at pH 9.2) was attached to the end of the MSPD syringe for on column clean-up of the hydrochloric acid extract and for transferring the target compounds to a suitable solvent for gas chromatography (GC) analysis. Therefore, the adsorbed analytes were directly eluted from the Oasis HLB cartridges with 2 mL of 2% acetic acid in methanol before concentration by N(2) stream evaporation and dry extract derivatization with N-methyl-tert-butylsilyltrifluoroacetamide (BSTFA) and chlorotrimethylsilane (TMCS). The optimization/evaluation of all the factors affecting the MSPD and on column clean-up procedures has led to a fast sample treatment, and analytes extraction and pre-concentration can be finished in approximately 30 min. The developed method has been applied to eight hair samples from poli-drug abusers and measured analyte concentrations have been found to be statistically similar (95% confidence interval) to those obtained after a conventional enzymatic hydrolysis method (Pronase E). Copyright © 2010. Published by Elsevier B.V.

  7. Sampling of tar from sewage sludge gasification using solid phase adsorption.

    Science.gov (United States)

    Ortiz González, Isabel; Pérez Pastor, Rosa Ma; Sánchez Hervás, José Ma

    2012-06-01

    Sewage sludge is a residue from wastewater treatment plants which is considered to be harmful to the environment and all living organisms. Gasification technology is a potential source of renewable energy that converts the sewage sludge into gases that can be used to generate energy or as raw material in chemical synthesis processes. But tar produced during gasification is one of the problems for the implementation of the gasification technology. Tar can condense on pipes and filters and may cause blockage and corrosion in the engines and turbines. Consequently, to minimize tar content in syngas, the ability to quantify tar levels in process streams is essential. The aim of this work was to develop an accurate tar sampling and analysis methodology using solid phase adsorption (SPA) in order to apply it to tar sampling from sewage sludge gasification gases. Four types of commercial SPA cartridges have been tested to determine the most suitable one for the sampling of individual tar compounds in such streams. Afterwards, the capacity, breakthrough volume and sample stability of the Supelclean™ ENVI-Carb/NH(2), which is identified as the most suitable, have been determined. Basically, no significant influences from water, H(2)S or NH(3) were detected. The cartridge was used in sampling real samples, and comparable results were obtained with the present and traditional methods.

  8. Indústria de cartucho de toner sob a ótica da remanufatura: estudo de caso de um processo de melhoria Remanufacturing of toner cartridge: a case study of a improvement process

    Directory of Open Access Journals (Sweden)

    Cícero Ferreira Fernandes Costa Filho

    2006-04-01

    Full Text Available Este trabalho apresenta um estudo de caso de um processo de melhoria aplicado a uma indústria de remanufatura de cartuchos de toner. Inicialmente, é feita uma abordagem do processo de remanufatura procurando salientar as principais características que o diferenciam de um processo de manufatura convencional e a importância do mesmo diante das preocupações ambientais atuais. Através de três indicadores de desempenho propostos no trabalho fez-se um diagnóstico do processo de remanufatura quanto ao aproveitamento de peças recolhidas do campo, atendimento de pedidos dos clientes e quantidade de defeitos. No diagnóstico inicial realizado, os valores obtidos para esses critérios situaram-se abaixo das metas estabelecidas na empresa. Através da metodologia PDCA, identificaram-se oportunidades de melhorias em pontos críticos do processo de fabricação. A implantação dessas melhorias resultou em ganhos nos indicadores de desempenho da ordem de 12%. Algumas ferramentas clássicas foram utilizadas para auxiliar na implementação da metodologia PDCA destacando-se brainstorming, diagrama de Ishikawa e Controle Estatístico de Processo.This paper presents an improvement process applied in one remanufacturing toner cartridge industry. It, initially, presents a mapping of the stages of this process by attempting to highlight the main characteristics, which distinguish it from a conventional manufacturing process and emphasizes its importance as an of eco-efficient process aiming at achieving sustainable development. Through three performance indicators proposed by the work, a diagnosis of the existing process was carried out as to the reuse of parts gasthered in the field, fulfilment of customers'orders and quantity of production faults. At the initial diagnosis carried out, the values obtained for theses criteria were located below the established targets proposed by the company. Through the PDCA tool, improvement opportunities in critical

  9. Chemical evaluation of electronic cigarettes.

    Science.gov (United States)

    Cheng, Tianrong

    2014-05-01

    To review the available evidence evaluating the chemicals in refill solutions, cartridges, aerosols and environmental emissions of electronic cigarettes (e-cigarettes). Systematic literature searches were conducted to identify research related to e-cigarettes and chemistry using 5 reference databases and 11 search terms. The search date range was January 2007 to September 2013. The search yielded 36 articles, of which 29 were deemed relevant for analysis. The levels of nicotine, tobacco-specific nitrosamines (TSNAs), aldehydes, metals, volatile organic compounds (VOCs), flavours, solvent carriers and tobacco alkaloids in e-cigarette refill solutions, cartridges, aerosols and environmental emissions vary considerably. The delivery of nicotine and the release of TSNAs, aldehydes and metals are not consistent across products. Furthermore, the nicotine level listed on the labels of e-cigarette cartridges and refill solutions is often significantly different from measured values. Phenolic compounds, polycyclic aromatic hydrocarbons and drugs have also been reported in e-cigarette refill solutions, cartridges and aerosols. Varying results in particle size distributions of particular matter emissions from e-cigarettes across studies have been observed. Methods applied for the generation and chemical analyses of aerosols differ across studies. Performance characteristics of e-cigarette devices also vary across and within brands. Additional studies based on knowledge of e-cigarette user behaviours and scientifically validated aerosol generation and chemical analysis methods would be helpful in generating reliable measures of chemical quantities. This would allow comparisons of e-cigarette aerosol and traditional smoke constituent levels and would inform an evaluation of the toxicity potential of e-cigarettes.

  10. Chemical evaluation of electronic cigarettes

    Science.gov (United States)

    Cheng, Tianrong

    2014-01-01

    Objective To review the available evidence evaluating the chemicals in refill solutions, cartridges, aerosols and environmental emissions of electronic cigarettes (e-cigarettes). Methods Systematic literature searches were conducted to identify research related to e-cigarettes and chemistry using 5 reference databases and 11 search terms. The search date range was January 2007 to September 2013. The search yielded 36 articles, of which 29 were deemed relevant for analysis. Results The levels of nicotine, tobacco-specific nitrosamines (TSNAs), aldehydes, metals, volatile organic compounds (VOCs), flavours, solvent carriers and tobacco alkaloids in e-cigarette refill solutions, cartridges, aerosols and environmental emissions vary considerably. The delivery of nicotine and the release of TSNAs, aldehydes and metals are not consistent across products. Furthermore, the nicotine level listed on the labels of e-cigarette cartridges and refill solutions is often significantly different from measured values. Phenolic compounds, polycyclic aromatic hydrocarbons and drugs have also been reported in e-cigarette refill solutions, cartridges and aerosols. Varying results in particle size distributions of particular matter emissions from e-cigarettes across studies have been observed. Methods applied for the generation and chemical analyses of aerosols differ across studies. Performance characteristics of e-cigarette devices also vary across and within brands. Conclusions Additional studies based on knowledge of e-cigarette user behaviours and scientifically validated aerosol generation and chemical analysis methods would be helpful in generating reliable measures of chemical quantities. This would allow comparisons of e-cigarette aerosol and traditional smoke constituent levels and would inform an evaluation of the toxicity potential of e-cigarettes. PMID:24732157

  11. Processamento de cartuchos de impressoras de jato de tinta: um exemplo de gestão de produto pós-consumo

    Directory of Open Access Journals (Sweden)

    Felipe Pereira de Moura

    2012-01-01

    Full Text Available This work presents a route for processing spent ink-jet cartridges in an experimental course. The disassembly of the cartridges requires several steps and the recognition of their different components is essential to define the best final destination (recycling, co-processing. The plastic strips were chemically processed so as to recover gold and copper. The students recognized the difficulty of processing multicomponent wastes and the importance of the chemical work under the best safety conditions; they also experienced many laboratory techniques and recognized the value of the selective collection and the reverse logistics to reach a viable commercial scale recycling.

  12. Determination of carbonyl compounds in air by HPLC

    International Nuclear Information System (INIS)

    Garcia, S.; Perez, R.M.; Campos, A.; Gonzalez, D.

    1995-01-01

    A method for the determination of seven carbonyl compounds in air is presented. The procedure involve sampling of air by a Sep-Pak Cartridge impregnated with 2,4-dinitrophenylhydrazine. Elution was done with 3 mL of acetonitrile and the eluate was diluted to 5 mL. The analysis was done by HPLC with UV detection and external standard method quantification. It has been achieved relative standard deviations about 5% and detection limits of 80 ng/cartridge for formaldehyde, acetaldehyde and acetoacetonitrile. Three different types of samples (rural, urban, petrol emission) were successfully analyzed. (Author) 12 refs

  13. Remote filter handling machine for Sizewell B

    International Nuclear Information System (INIS)

    Barker, D.

    1993-01-01

    Two Filter Handling machines (FHM) have been supplied to Nuclear Electric plc for use at Sizewell B Power Station. These machines have been designed and built following ALARP principles with the functional objective being to remove radioactive filter cartridges from a filter housing and replace them with clean filter cartridges. Operation of the machine is achieved by the prompt of each distinct task via an industrial computer or the prompt of a full cycle using the automatic mode. The design of the machine features many aspects demonstrating ALARP while keeping the machine simple, robust and easy to maintain. (author)

  14. Water Purification

    Science.gov (United States)

    1994-01-01

    The Vision Catalyst Purifier employs the basic technology developed by NASA to purify water aboard the Apollo spacecraft. However, it also uses an "erosion" technique. The purifier kills bacteria, viruses, and algae by "catalytic corrosion." A cartridge contains a silver-impregnated alumina bed with a large surface area. The catalyst bed converts oxygen in a pool of water to its most oxidative state, killing over 99 percent of the bacteria within five seconds. The cartridge also releases into the pool low levels of ionic silver and copper through a controlled process of erosion. Because the water becomes electrochemically active, no electricity is required.

  15. Determination of carbonyl compounds in air by HPLC; Determinacion de compuestos carbonilicos en aire por HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, S; Perez, R M; Campos, A; Gonzalez, D

    1995-07-01

    A method for the determination of seven carbonyl compounds in air is presented. The procedure involve sampling of air by a Sep-Pak Cartridge impregnated with 2,4-dinitrophenylhydrazine. Elution was done with 3 mL of acetonitrile and the eluate was diluted to 5 mL. The analysis was done by HPLC with UV detection and external standard method quantification. It has been achieved relative standard deviations about 5% and detection limits of 80 ng/cartridge for formaldehyde, acetaldehyde and acetoacetonitrile. Three different types of samples (rural, urban, petrol emission) were successfully analyzed. (Author) 12 refs.

  16. Micropropagation, antinociceptive and antioxidant activities of extracts of Verbena litoralis Kunth (Verbenaceae).

    Science.gov (United States)

    Braga, Virgínia F; Mendes, Giselle C; Oliveira, Raphael T R; Soares, Carla Q G; Resende, Cristiano F; Pinto, Leandro C; Santana, Reinaldo de; Viccini, Lyderson F; Raposo, Nádia R B; Peixoto, Paulo H P

    2012-03-01

    This work describes an efficient micropropagation protocol for Verbena litoralis and the study of the antinociceptive and antioxidant activities in extracts of this species. For the establishment in vitro, surface-sterilization procedures and PVPP showed high efficiency in fungal-bacterial contamination and phenol oxidation controls. Nodal segments cultivation in MS medium supplemented with 6-benzyladenine (7.5 µM)/α-naphthaleneacetic acid (NAA; 0.005 µM) induced multiple shoots. Elongated shoots were rooted with IAA (0.2 µM). Acclimatization rates were elevated and the plants showed the typical features of this species. The hexanic fraction (HF) of powdered leaves presented a radical scavenging activity with IC(50) = 169.3 µg mL(-1). HF showed a non-dose dependent analgesic activity in the writhing test; its antinociceptive activity in the hot plate test was restricted to 500 mg kg(-1), which is the highest dose. The results of this study showed the potential of tissue culture on conservation and large scale multiplication and confirmed the traditional folk medicine use of V. litoralis.

  17. Integrated passive flux measurement in groundwater: design and performance of iFLUX samplers

    Science.gov (United States)

    Verreydt, Goedele; Razaei, Meisam; Meire, Patrick; Van Keer, Ilse; Bronders, Jan; Seuntjens, Piet

    2017-04-01

    The monitoring and management of soil and groundwater is a challenge. Current methods for the determination of movement or flux of pollution in groundwater use no direct measurements but only simulations based on concentration measurements and Darcy velocity estimations. This entails large uncertainties which cause remediation failures and higher costs for contaminated site owners. On top of that, the lack of useful data makes it difficult to get approval for a risk-based management approach which completely avoids costly remedial actions. The iFLUX technology is a key development of Dr. Goedele Verreydt at the University of Antwerp and VITO. It is supported by the passive flux measurement technology as invented by Prof. Mike Annable and his team at the University of Florida. The iFLUX technology includes an in situ measurement device for capturing dynamic groundwater quality and quantity, the iFLUX sampler, and an associated interpretation and visualization method. The iFLUX sampler is a modular passive sampler that provides simultaneous in situ point determinations of a time-averaged target compound mass flux and water flux. The sampler is typically installed in a monitoring well where it intercepts the groundwater flow and captures the compounds of interest. The sampler consists of permeable cartridges which are each packed with a specific sorbent matrix. The sorbent matrix of the water flux cartridge is impregnated with known amounts of water soluble resident tracers. These tracers are leached from the matrix at rates proportional to the groundwater flux. The measurements of the contaminants and the remaining resident tracer are used to determine groundwater and target compound fluxes. Exposure times range from 1 week to 6 months, depending on the expected concentration and groundwater flow velocity. The iFLUX sampler technology has been validated and tested at several field projects. Currently, 4 cartridges are tested and available: 1 waterflux cartridge to

  18. Interpretation of measurements made by oscillations of irradiated fuels in natural uranium, graphite-gas piles

    International Nuclear Information System (INIS)

    Laponche, Bernard; Luffin, Jean; Brunet, Max; Guerange, Jacques; Tonolli, Jacky

    1969-06-01

    When considering a pile operation, it is interesting to know the evolution of fuel quality with respect to irradiation, i.e. the variation of its fission rate and of its absorption rate. In order to experimentally obtain these features, a method is to introduce an irradiated cartridge into a critical reactor and to measure the induced effect on its reactivity and on the neutron density at the vicinity of the cartridge. An oscillation method presented in another document and based on a periodic introduction of fuel sample into a critical reactor allows, from the measurement of reactivity variation (global signal), and of the neutron density (local signal), effective macroscopic fission and absorption cross sections of this sample to be obtained. As previous studies revealed that the interpretation of the local signal was notably delicate, this information has been replaced by computed information, the fission rate, which is determined by means of the COREGRAF1 code. Thus, the remaining quantity to be obtained is the fuel absorption rate. The authors report studies performed on several sets of cartridges from different reactors, and with an irradiation range from about 700 to 4000 MWJ/T. In a first part, they describe the characteristics of the studied cartridges, their irradiation and measurement conditions, and the use of the evolution code. In a second part, they try to define the interpretation of oscillation-based measurements by using two methods, a first and fast one which gives an approximation of results, and a more elaborated second one which complies with measurement conditions. The last part presents and discusses the obtained results [fr

  19. Neural organisation in the first optic ganglion of the nocturnal bee Megalopta genalis.

    Science.gov (United States)

    Greiner, Birgit; Ribi, Willi A; Wcislo, William T; Warrant, Eric J

    2004-11-01

    Each neural unit (cartridge) in the first optic ganglion (lamina) of the nocturnal bee Megalopta genalis contains nine receptor cell axons (6 short and 3 long visual fibres), and four different types of first-order interneurons, also known as L-fibres (L1 to L4) or lamina monopolar cells. The short visual fibres terminate within the lamina as three different types (svf 1, 2, 3). The three long visual fibres pass through the lamina without forming characteristic branching patterns and terminate in the second optic ganglion, the medulla. The lateral branching pattern of svf 2 into adjacent cartridges is unique for hymenopterans. In addition, all four types of L-fibres show dorso-ventrally arranged, wide, lateral branching in this nocturnal bee. This is in contrast to the diurnal bees Apis mellifera and Lasioglossum leucozonium, where only two out of four L-fibre types (L2 and L4) reach neighbouring cartridges. In M. genalis, L1 forms two sub-types, viz. L1-a and L1-b; L1-b in particular has the potential to contact several neighbouring cartridges. L2 and L4 in the nocturnal bee are similar to L2 and L4 in the diurnal bees but have dorso-ventral arborisations that are twice as wide. A new type of laterally spreading L3 has been discovered in the nocturnal bee. The extensive neural branching pattern of L-fibres in M. genalis indicates a potential role for these neurons in the spatial summation of photons from large groups of ommatidia. This specific adaptation in the nocturnal bee could significantly improve reliability of vision in dim light.

  20. Biologically based machine vision: signal analysis of monopolar cells in the visual system of Musca domestica.

    Science.gov (United States)

    Newton, Jenny; Barrett, Steven F; Wilcox, Michael J; Popp, Stephanie

    2002-01-01

    Machine vision for navigational purposes is a rapidly growing field. Many abilities such as object recognition and target tracking rely on vision. Autonomous vehicles must be able to navigate in dynamic enviroments and simultaneously locate a target position. Traditional machine vision often fails to react in real time because of large computational requirements whereas the fly achieves complex orientation and navigation with a relatively small and simple brain. Understanding how the fly extracts visual information and how neurons encode and process information could lead us to a new approach for machine vision applications. Photoreceptors in the Musca domestica eye that share the same spatial information converge into a structure called the cartridge. The cartridge consists of the photoreceptor axon terminals and monopolar cells L1, L2, and L4. It is thought that L1 and L2 cells encode edge related information relative to a single cartridge. These cells are thought to be equivalent to vertebrate bipolar cells, producing contrast enhancement and reduction of information sent to L4. Monopolar cell L4 is thought to perform image segmentation on the information input from L1 and L2 and also enhance edge detection. A mesh of interconnected L4's would correlate the output from L1 and L2 cells of adjacent cartridges and provide a parallel network for segmenting an object's edges. The focus of this research is to excite photoreceptors of the common housefly, Musca domestica, with different visual patterns. The electrical response of monopolar cells L1, L2, and L4 will be recorded using intracellular recording techniques. Signal analysis will determine the neurocircuitry to detect and segment images.

  1. Different insulin concentrations in resuspended vs. unsuspended NPH insulin: Practical aspects of subcutaneous injection in patients with diabetes.

    Science.gov (United States)

    Lucidi, P; Porcellati, F; Marinelli Andreoli, A; Candeloro, P; Cioli, P; Bolli, G B; Fanelli, C G

    2017-06-06

    This study measured the insulin concentration (Ins [C] ) of NPH insulin in vials and cartridges from different companies after either resuspension (R+) or not (R-; in the clear/cloudy phases of unsuspended NPH). Measurements included Ins [C] in NPH(R+) and in the clear/cloudy phases of NPH(R-), and the time needed to resuspend NPH and time for NPH(R+) to separate again into clear/cloudy parts. In vials of NPH(R+) (assumed to be 100%), Ins [C] in the clear phase of NPH(R-) wasEli Lilly NPH, respectively. Likewise, in pen cartridges, Ins [C] in the clear phase of NPH(R-) wasLilly and Sanofi NPH. Time needed to resuspend NPH (spent in tipping) in vials was brief with both Novo (5±1s) and Lilly NPH (6±1s), but longer with all pen cartridges (50±8s, 40±6s and 30±4s from Novo, Lilly and Sanofi, respectively; P=0.022). Time required for 50% separation into cloudy and clear parts of NPH was longer with Novo (60±7min) vs. Lilly (18±3min) in vials (P=0.021), and affected by temperature, but not by the different diameter sizes of the vials. With pen cartridges, separation into clear and cloudy parts was significantly faster than in vials (P<0.01). Ins [C] in NPH preparations varies depending on their resuspension or not. Thus, subcutaneous injection of the same number of units of NPH in patients with diabetes may deliver different amounts of insulin depending on its prior NPH resuspension. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Methylparaben concentration in commercial Brazilian local anesthetics solutions

    Directory of Open Access Journals (Sweden)

    Gustavo Henrique Rodriguez da Silva

    2012-08-01

    Full Text Available OBJECTIVE: To detect the presence and concentration of methylparaben in cartridges of commercial Brazilian local anesthetics. MATERIAL AND METHODS: Twelve commercial brands (4 in glass and 8 in plastic cartridges of local anesthetic solutions for use in dentistry were purchased from the Brazilian market and analyzed. Different lots of the commercial brands were obtained in different Brazilian cities (Piracicaba, Campinas and São Paulo. Separation was performed using high performance liquid chromatography (HPLC with UV-Vis detector. The mobile phase used was acetonitrile:water (75:25 - v/v, pH 4.5, adjusted with acetic acid at a flow rate of 1.0 ml.min-1. RESULTS: When detected in the solutions, the methylparaben concentration ranged from 0.01% (m/v to 0.16% (m/v. One glass and all plastic cartridges presented methylparaben. CONCLUSION: 1. Methylparaben concentration varied among solutions from different manufacturers, and it was not indicated in the drug package inserts; 2. Since the presence of methylparaben in dental anesthetics is not regulated by the Brazilian National Health Surveillance Agency (ANVISA and this substance could cause allergic reactions, it is important to alert dentists about its possible presence.

  3. Comparison between Different Extraction Methods for Determination of Primary Aromatic Amines in Food Simulant

    Directory of Open Access Journals (Sweden)

    Morteza Shahrestani

    2018-01-01

    Full Text Available The primary aromatic amines (PAAs are food contaminants which may exist in packaged food. Polyurethane (PU adhesives which are used in flexible packaging are the main source of PAAs. It is the unreacted diisocyanates which in fact migrate to foodstuff and then hydrolyze to PAAs. These PAAs include toluenediamines (TDAs and methylenedianilines (MDAs, and the selected PAAs were 2,4-TDA, 2,6-TDA, 4,4′-MDA, 2,4′-MDA, and 2,2′-MDA. PAAs have genotoxic, carcinogenic, and allergenic effects. In this study, extraction methods were applied on a 3% acetic acid as food simulant which was spiked with the PAAs under study. Extraction methods were liquid-liquid extraction (LLE, dispersive liquid-liquid microextraction (DLLME, and solid-phase extraction (SPE with C18 ec (octadecyl, HR-P (styrene/divinylbenzene, and SCX (strong cationic exchange cartridges. Extracted samples were detected and analyzed by HPLC-UV. In comparison between methods, recovery rate of SCX cartridge showed the best adsorption, up to 91% for polar PAAs (TDAs and MDAs. The interested PAAs are polar and relatively soluble in water, so a cartridge with cationic exchange properties has the best absorption and consequently the best recoveries.

  4. Radioimmunoassay in microtiter plates

    International Nuclear Information System (INIS)

    Hirschberg, T.; Hirschberg, H.

    1987-01-01

    A radioimmunoassay was performed in the wells of casein-coated microplates employing 125 I-labelled sheep anti-human second antibody. The antigen-antibody complexes were thereafter dislodged from the well walls using detergent sodium dodecyl sulfate (SDS) and the entire contents of the wells were simultaneously absorbed into 48 cellulose acetate-absorbing cartridges. All 48 cartridges were transferred to counting vials and the radioactivity determined by standard gamma counting techniques. The particular advantage of the method described here is the ease with which the supernatants can be collected and transferred to counting vials with minimal handling of radioactive samples. 6 refs.; 1 figure; 1 table

  5. Sistema limpo em linha para extração em fase sólida de contaminantes emergentes em águas naturais An in-line clean system for the solid-phase extraction of emerging contaminants in natural waters

    Directory of Open Access Journals (Sweden)

    Fernando F. Sodré

    2010-01-01

    Full Text Available A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L using commercial solid-phase extraction (SPE cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.

  6. New techniques for improved performance in surface blasting operation and optimisation of blast design parameters

    Energy Technology Data Exchange (ETDEWEB)

    Roy, P.P. [Central Mining Research Institute, Dhanbad (India). Blasting Dept.

    1999-02-01

    Experimental blasts were conducted for optimisation of blasting parameters using separate technologies involving non-electric initiation systems, air decking accessories in conjunction with different explosive products like emulsion (cartridge and site-mixed), slurries (cartridge and site-mixed) and ANFO. The cost associated with each such technology was then compared with the conventional methods of drilling and blasting operations. The results of cost analyses are given. Theoretical and practical aspects of such technologies and their best possible usage in order to establish the desired fragmentation, muck profile, wall control and ultimately the accepted level of costs are mentioned in subsequent sections. 16 refs., 17 figs., 8 plates, 11 tabs.

  7. Preliminary results for the detection method of perfluoroalkyl substances (PFASs residues in pork

    Directory of Open Access Journals (Sweden)

    Shih-kuo Lin

    2017-05-01

    Full Text Available The perfluoroalkyl substances (PFASs residues, which come from environmental pollution, tend to accumulate in the food chain (EFSA, 2008; Guerranti et al., 2013. 17 chemicals of PFASs family were selected for this study. Fresh pork samples were extracted by Waters® WAX SPE (solid phase extraction cartridges. All extracted samples were analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS. The results of calibration curves of each PFAS were good, the R2 values ranging from 0.9901 to 0.9993. The Recoveries were in the range 80%-119%. The protocol of extraction by Waters® WAX SPE cartridge will be applied in future studies.

  8. Protection for work on channel W.19.E of the pile G.2

    International Nuclear Information System (INIS)

    Rodier, J.; Chassany, J.Ph.

    1961-01-01

    The cartridges stuck in one of the channels, resulting from a canning burst and attempts at unloading, were removed from the front. Contamination was kept under control by the use of vinyl protective equipment, the working areas being defined and corresponding clothing worn. Constant supervision of the irradiation due to scraps and to the cartridges kept the doses absorbed down to a negligible level. As a result of this very strict discipline on the question of radioactive hygiene there was no spread of contamination nor any irradiation accident in the course of this work, which lasted about a month and involved 3,335 trips to the area. (author) [fr

  9. 25MM Plastic Telescoped Cartridge Case Development Program

    Science.gov (United States)

    1975-01-01

    Mat’ I____ Projectile: 0wq. No. 30033;7,Rev, A, Platic "Band, 3000 Grain. Primer: Type .SmL. , Lot No.,, , Ne. . Flash Tubet.l3TSpe 1ell Project l...8217 _ ’_"__ Projectile: Dwg. No. 300347, Ray. A, Platic Biand, 3000 Graln. Primer: Type P-SIT.ML , Lot No. . No, Flash Tube:c<# 7’Tr-pecla1, Projectile Rot ntlo...Case: N ,o Rev. ___, Mati:.l, ILt Dwg. No,._____ Rev. M Nt l______Projectile: Dwg, No. 300347, ev • A, Platic ’ t -and, 3000 Grain, Primers Type , Lot

  10. 21 CFR 520.1450b - Morantel tartrate cartridge.

    Science.gov (United States)

    2010-04-01

    ... grazing season. (2) Indications for use. For control of the adult stage of the following gastrointestinal... dosing gun to all cattle that will be grazing the same pasture. Effectiveness of the drug product is dependent upon continuous control of the gastrointestinal parasites for approximately 90 days following...

  11. Tissue Engineered Skeletal Myofibers can Directly "Sense" Gravitational Force Changes

    Science.gov (United States)

    Vandenburgh, Herman H.; Shansky, J.; DelTatto, M.; Lee, Peter; Meir, J.

    1999-01-01

    Long-term manned space flight requires a better understanding of skeletal muscle atrophy resulting from microgravity. Atrophy most likely results from changes at both the systemic level (e.g. decreased circulating growth hormone, increased circulating glucocorticoids) and locally (e.g. decreased myofiber resting tension). Differentiated skeletal myofibers in tissue culture have provided a model system over the last decade for gaining a better understanding of the interactions of exogenous growth factors, endogenous growth factors, and muscle fiber tension in regulating protein turnover rates and muscle cell growth. Tissue engineering these cells into three dimensional bioartificial muscle (BAM) constructs has allowed us to extend their use to Space flight studies for the potential future development of countermeasures. Embryonic avian muscle cells were isolated and BAMs tissue engineered as described previously. The myoblasts proliferate and fuse into aligned postmitotic myofibers after ten to fourteen days in vitro. A cylindrical muscle-like structure containing several thousand myofibers is formed which is approximately 30 mm in length, 2-3 mm in diameter, and attached at each end. For the Space Shuttle experiments, the BAMs were transferred to 55 mL bioreactor cartridges (6 BAMs/cartridge). At Kennedy Space Center, the cartridges were mounted in two Space Tissue Loss (STL) Modules (three to four cartridges per Module) and either maintained as ground controls or loaded in a Mid-Deck locker of the Space Shuttle. The BAM cartridges were continuously perfused during the experiment at 1.5 mL/ min with tissue culture medium. Eighteen BAMs were flown for nine days on Mission STS66 while eighteen BAMs served as ground controls. The complete experiment was repeated on Mission STS77 with twenty four BAMs in each group. BAMs could be maintained in a healthy state for at least 30 days in the perfusion bioreactor cartridges. The BAM muscle fibers directly detected both the

  12. Micropropagation, antinociceptive and antioxidant activities of extracts of Verbena litoralis Kunth (Verbenaceae

    Directory of Open Access Journals (Sweden)

    Virgínia F. Braga

    2012-03-01

    Full Text Available This work describes an efficient micropropagation protocol for Verbena litoralis and the study of the antinociceptive and antioxidant activities in extracts of this species. For the establishment in vitro, surface-sterilization procedures and PVPP showed high efficiency in fungal-bacterial contamination and phenol oxidation controls. Nodal segments cultivation in MS medium supplemented with 6-benzyladenine (7.5 µM/α-naphthaleneacetic acid (NAA; 0.005 µM induced multiple shoots. Elongated shoots were rooted with IAA (0.2 µM. Acclimatization rates were elevated and the plants showed the typical features of this species. The hexanic fraction (HF of powdered leaves presented a radical scavenging activity with IC50 = 169.3 µg mL-1. HF showed a non-dose dependent analgesic activity in the writhing test; its antinociceptive activity in the hot plate test was restricted to 500 mg kg-1, which is the highest dose. The results of this study showed the potential of tissue culture on conservation and large scale multiplication and confirmed the traditional folk medicine use of V. litoralis.Este trabalho descreve um protocolo eficiente de micropropagação para Verbena litoralis e estuda as atividades antinociceptiva e antioxidante de extratos desta espécie. Para o estabelecimento in vitro, os procedimentos de desinfecção e o PVPP mostraram alta eficiência no controle da contaminação por fungos e bactérias e da oxidação fenólica. O cultivo de segmentos nodais em meio MS suplementado com 6-benziladenina (7,5 µM e ácido α-naftalenoacético (ANA; 0,005 µM induziu múltiplos brotos. Brotos alongados foram enraizados com AIA (0,2 µM. As taxas de aclimatização foram elevadas e as plantas apresentaram características típicas da espécie. A fração hexânica (FH de folhas trituradas apresentou atividade sequestradora de radicais livres com IC50 = 169,3 µg mL-1. A FH mostrou atividade analgésica não dose-dependente no teste das contor

  13. Development of a recovery method of 131I in the 99Mo process through the fission of 235U

    International Nuclear Information System (INIS)

    Bignardi, Aline Moraes Teixeira

    2013-01-01

    13 1 I is an iodine radioisotope widely used in nuclear medicine that can be used either for diagnostic or for treatment due to its physical decay by β - and its high emission of y-rays. It is produced at IPEN using the indirect reaction: 130 Te(n,y) 131m Te → 131 Te → 131 I where TeO 2 targets are irradiated in a Nuclear Reactor. There is also the possibility of producing 131 I by the fission of 235 U, where about 300 different elements are produced together with 131 I. The 131 I produced through this method presents high specific activity and radioactive concentration suitable for the labeling of molecules. The aim of this work was to develop a recovery method of 131 I with the required quality to be used in Nuclear Medicine in the 99 Mo production process through the route of acid dissolution of metallic 235 U targets. 131 I can appear in two phases of the process, both in the gaseous phase produced during the dissolution of metallic U targets and in the dissolution solution. This work studied the recovery of 131 I in these two phases. Several materials were used for the capture and recovery of 131 I at the two phases of the process, the gaseous one and the solution of dissolution of U targets. Columns of alumina with Cu, acid alumina with Cu, Ag microspheres, Cu microspheres, Ag nanospheres, anionic cartridges, Ag cartridges, anion exchange resin and activated charcoal columns were tested. Solutions containing 131 I in 0.1 mol.L -1 NaOH were percolated through the materials and the eluted solutions were analyzed in a dose calibrator. The precipitation of AgI was also studied wth further dissolution of this precipitate with 0.1 mol L -1 NH 4 OH and 5% Na 2 S 2 O 3 . The recovery results varied according to the material, activated charcoal showed recovery yields between 42% and 83% but the recovery yield of the alumina column with Cu ranged from 20% to 85%. Tests with Ag nanospheres showed recovery yield of 26% using 0.1 mol L -1 NaOH and 72% for Na 2 S 2 O

  14. Domestic Preparedness Program: Sarin Vapor Challenge and Corn Oil Protection Factor (PF) Testing of Commercial Air-Purifying Negative Pressure Respirators

    National Research Council Canada - National Science Library

    Campbell, Lee

    2003-01-01

    ...) corn-oil protection factor determinations of NPR systems using human subjects. Results indicate that cartridges provide adequate resistance to GB breakthrough against high-concentration challenges...

  15. Field Deployable Method for Arsenic Speciation in Water.

    Science.gov (United States)

    Voice, Thomas C; Flores Del Pino, Lisveth V; Havezov, Ivan; Long, David T

    2011-01-01

    Contamination of drinking water supplies by arsenic is a world-wide problem. Total arsenic measurements are commonly used to investigate and regulate arsenic in water, but it is well understood that arsenic occurs in several chemical forms, and these exhibit different toxicities. It is problematic to use laboratory-based speciation techniques to assess exposure as it has been suggested that the distribution of species is not stable during transport in some types of samples. A method was developed in this study for the on-site speciation of the most toxic dissolved arsenic species: As (III), As (V), monomethylarsonic acid (MMA) and dimethylarsenic acid (DMA). Development criteria included ease of use under field conditions, applicable at levels of concern for drinking water, and analytical performance.The approach is based on selective retention of arsenic species on specific ion-exchange chromatography cartridges followed by selective elution and quantification using graphite furnace atomic absorption spectroscopy. Water samples can be delivered to a set of three cartridges using either syringes or peristaltic pumps. Species distribution is stable at this point, and the cartridges can be transported to the laboratory for elution and quantitative analysis. A set of ten replicate spiked samples of each compound, having concentrations between 1 and 60 µg/L, were analyzed. Arsenic recoveries ranged from 78-112 % and relative standard deviations were generally below 10%. Resolution between species was shown to be outstanding, with the only limitation being that the capacity for As (V) was limited to approximately 50 µg/L. This could be easily remedied by changes in either cartridge design, or the extraction procedure. Recoveries were similar for two spiked hard groundwater samples indicating that dissolved minerals are not likely to be problematic. These results suggest that this methodology can be use for analysis of the four primary arsenic species of concern in

  16. 123I-Iodomethyl tyrosine radiochemical synthesis and quantification of residual impurities after SepPak purification

    International Nuclear Information System (INIS)

    Matte, G.; Abrams, D.; Kumar, P.; Mercer, J.

    2002-01-01

    [123-I]-Iodomethyl tyrosine, an analog of tyrosine, is used as a radiopharmaceutical to detect malignant tissue in vivo. Initial synthesis report removal of the starting material using HPLC reversed phase chromatography as well as a simple method using a C18-SepPak cartridge when an HPLC system is not available. Small amounts of residual starting material have not been reported to interfere with tumor uptake following biodistribution in vivo. However, in vitro tissue culture studies do require the final product to be free of un-reacted methyl tyrosine. Our goal was to quantify the amount of residual methyl tyrosine after C18-SepPak purification to confirm that 123 I methyl tyrosine purified in this manner would be suitable tissue culture studies. A preconditioned (rinsed with 2 ml Ethanol and 8 ml PBS) C18-SepPak cartridge is loaded with the 123 I-iodomethyl tyrosine reaction mixture and washed with 8 mL of PBS to remove the un-reacted methyl tyrosine and free 123 I-iodide. The cartridge is then eluted with a 20% alcohol/PBS mixture to recover the 123 I-iodomethyl tyrosine. Paper chromatography confirmed the removal of un-reacted 123 I-iodide. A parallel study with a methyl tyrosine standard was used to confirm the removal of the methyl tyrosine from the SepPak cartridge during the washing with 8 mL of PBS. Fractions were collected and UV absorbance was recorded. A standard curve was prepared using the UV absorbance of serial dilutions of methyl tyrosine. The detection limit was in the order of ng/mL. An elution profile of both 123 I methyl tyrosine and methyl tyrosine was obtained and shows that traces of methyl tyrosine can still be present after an 8 mL PBS wash

  17. Cell mediated lympholysis: CML. A microplate technique requiring few target cells and employing a new method of supernatant collection

    International Nuclear Information System (INIS)

    Hirschberg, A.; Thorsby, E.

    1977-01-01

    A micromethod for the 51 Cr release assay is described. Allogeneically induced cytotoxic lymphocytes are generated in mixed lymphocyte microcultures in the wells of microplates. Their cytotoxic capacity is assayed by adding 51 Cr-labelled PHA derived lymphoblasts directly into the microcultures with no pooling or transfer of the cytotoxic effector cells being required. The 51 Cr isotope released into the cell supernatants is collected by inserting a cellulose acetate absorption cartridge into each well. A glass fiber filter attached to the cartridge effectively separates the supernatant from the cellular elemets. This system allows the simultaneous collection of the supernatant from 96 wells, and can be used with either adherent or non-adherent target cells

  18. Proton and neutron polarized targets for nucleon-nucleon experiments at SATURNE II

    International Nuclear Information System (INIS)

    Ball, J.; Combet, M.; Sans, J.L.; Benda, B.; Chaumette, P.; Deregel, J.; Durand, G.; Dzyubak, A.P.; Gaudron, C.; Lehar, F.; Janout, Z.; Khachaturov, B.A.

    1996-01-01

    A SATURNE polarized target has been used for nucleon-nucleon elastic scattering and transmission experiments for 15 years. The polarized proton target is a 70 cm 3 cartridge loaded with Pentanol-2. For polarized neutron target, two cartridges loaded with 6 LiD and 6 LiH are set in the refrigerator and can be quickly inserted in the beam. First experiments using 6 Li products in quasielastic pp or pn analyzing power measurements are compared with the same observables measured in a free nucleon-nucleon scattering using polarized proton targets. Angular distribution as a function of a kinematically conjugate angle and coplanarity in nucleon-nucleon scattering is shown for different targets. (author)

  19. [Surgical peculiarities of gunshot injuries to arteries of the extremities caused by modern small arms and light weapons].

    Science.gov (United States)

    Samokhvalov, I M; Reva, V A; Denisov, A V; Ozeretskovskiĭ, L B; Pronchenko, A A

    2014-10-01

    The aim of the given study was development of surgical tactics in case of femoral artery injury, caused by medium-calibre bullet, on the basis acute experiment on large biological objects. Experimental animals were shot into mid third of the femora by a rifle cartridge in 7,62-mm calibre (AK-47 made in 1943). The analysis of microstructure, made in 5 cross-sections performed every 1-centimetre way from the wound canal, showed that there were no any damages of arterial wall. Authors came to conclusion that the surgical debridement of the gunshot wound, made by a rifle cartridge in 7,62-mm calibre of AK-47, should consist of exsection of devitalized section of artery.

  20. Early experience with a picture archiving and communication system for X-ray CT

    International Nuclear Information System (INIS)

    Nakano, Y.; Komori, M.; Minato, K.

    1987-01-01

    A network using fiberoptic ring architecture has been implemented to connect an x-ray CT unit with an image work station and optical disk storage unit. The work station has three noninterlaced cathode-ray tube (CRT) monitors of 1,024 X 1,024 pixels. The optical disk system stores 32 optical disk cartridges (2.6 Gbytes per cartridge). A general-purpose interface bus is used for communication between the CT unit and the network interface unit. Transfer time from CT to interface unit is 40 kbyte/second, 5 seconds per image. On-line data acquisition, long-term archiving, and CT interpretation using CRTs have been tested and the system has been working for 3 months in a clinical environment

  1. In situ synthesis of nanoparticles on substrates by inkjet printing

    KAUST Repository

    Abulikemu, Mutalifu; Jabbour, Ghassan

    2014-01-01

    Nanoparticles may be formed on a substrate by mixing precursor solutions deposited by an inkjet printer. A first solution is deposited on a substrate from a first inkjet print cartridge. Then, a second solution is deposited on the substrate from a second inkjet print cartridge. The solutions may be printed in an array of droplets on the substrate. Nanoparticles form when droplets of the first solution overlap with droplets of the second solution. In one example, the nanoparticles may be gold nanoparticles formed from mixing a first solution of 1,2-dichlorobenzene (DCB) and oleylamine and a second solution of gold chloride trihydrite and dimethyl sulfoxide (DMSO). The nanoparticles may be incorporated into optoelectronic devices.

  2. In situ synthesis of nanoparticles on substrates by inkjet printing

    KAUST Repository

    Abulikemu, Mutalifu

    2014-12-23

    Nanoparticles may be formed on a substrate by mixing precursor solutions deposited by an inkjet printer. A first solution is deposited on a substrate from a first inkjet print cartridge. Then, a second solution is deposited on the substrate from a second inkjet print cartridge. The solutions may be printed in an array of droplets on the substrate. Nanoparticles form when droplets of the first solution overlap with droplets of the second solution. In one example, the nanoparticles may be gold nanoparticles formed from mixing a first solution of 1,2-dichlorobenzene (DCB) and oleylamine and a second solution of gold chloride trihydrite and dimethyl sulfoxide (DMSO). The nanoparticles may be incorporated into optoelectronic devices.

  3. Tandem Solid Phase Extraction for the Determination of Pharmaceuticals in Wastewater

    International Nuclear Information System (INIS)

    Licaberth Ismail; Rozita Osman; Norashikin Saim

    2013-01-01

    In this study, a simple and rapid tandem solid phase extraction (SPE) was developed for the analysis of seven pharmaceuticals (acetaminophen, caffeine, carbamazepine, diclofenac, naproxen, ibuprofen and metaprolol) in wastewater sample. The novel aspect of coupling SPE cartridge in tandem is the ability to simplify the SPE procedure (sample introduction step) as no single sorbent was able to retain and concentrate all selected compounds since these compounds are of different physicochemical properties. A tandem SPE cartridges using Oasis HLB and octadecyl bonded silica (C 18 ) was found to be efficient with the advantages of minimizing sample volume and reducing analysis time. Using this approach, carbamazepine, diclofenac, naproxen and metaprolol were trapped in the Oasis HLB while acetaminophen, caffeine and ibuprofen were trapped in the second cartridge (C 18 ). The instrumental limits of detection (LOD) ranged from 0.01 to 0.04 μg/ L and satisfactory recoveries were obtained between 76 % to 104 %. The calibration curves were linear from 0.1 to 5.0 μg/ mL, with correlation coefficients (R 2 ) in the range of 0.995 to 0.999. The developed method was applied to the analysis of pharmaceuticals in wastewater samples. The amount of pharmaceuticals detected in wastewater samples varied from 0.4 to 24.5 mg/ L. (author)

  4. Anesthetic success of 1.8ml lidocaine 2% for mandibular tooth extraction. A pilot study

    Directory of Open Access Journals (Sweden)

    Pedro Aravena

    2013-04-01

    Full Text Available Aim: To determine the anesthetic effect of a 1.8ml cartridge of anesthetic lidocaine 2% with epinephrine 1:100,000 in inferior alveolar nerve block (NAI for the extraction in mandibular teeth. Material and methods: A pilot study with analitic design. Participating patients of Dental Emergency Service volunteers from Valdivia-Chile for mandibular teeth extractions attending between May and July of 2010. The anesthetic technique was performed by a dentist using only one cartridge of anesthetic to the NAI. After 15 minutes, the effect was considered effective when anesthetic not require reinforcement with additional anesthesia during extraction of teeth. We analyzed the relationship between success anesthetic effect with sex, age, diagnosis of tooth and type and level of pain observed (chi-square and logistic regression, p<0.05. Results: 62 patients were selected, of which only 47(75.8% was achieved anesthetic success. There was no statistical association with sex, age, type or dental diagnosis and perceived pain. Conclusion: Using a 1.8ml cartridge of anesthesia was effective in three of four patients treated by extraction of mandibular teeth. It suggests further research in relation to the clinical effectiveness of other anesthetics with the same dose in NAI.

  5. Speciation analysis of tellurium by solid-phase extraction in the presence of ammonium pyrrolidine dithiocarbamate and inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Chunhai; Cai, Qiantao; Guo, Zhong-Xian; Yang, Zhaoguang [Centre for Advanced Water Technology, Innovation Centre (NTU), Singapore (Singapore); Khoo, Soo Beng [Department of Chemistry, National University of Singapore (Singapore)

    2003-05-01

    Under acidic conditions tellurium(IV) formed a complex with ammonium pyrrolidine dithiocarbamate (APDC). The tellurium(IV) complex was completely retained on a non-polar Isolute silica-based octadecyl (C{sub 18}) sorbent-containing solid-phase extraction (SPE) cartridge, while the uncomplexed Te(VI) passed through the cartridge and remained as a free species in the solution. Only partial Te(IV) was retained on the SPE cartridge for samples without addition of APDC. On the basis of different retention behaviours of the complexed Te(IV) and uncomplexed Te(VI), a simple and highly sensitive method is proposed for the determination of total tellurium and Te(VI) by SPE separation and inductively coupled plasma mass spectrometry (ICP-MS) detection. The Te(IV) concentration was calculated as the difference between total tellurium and Te(VI) concentrations. The detection limit (3{sigma}) is 3 ng L{sup -1} tellurium. Factors affecting the separation and detection of tellurium species were investigated. Coexisting ions did not show significant interferences with the Te(IV)-APDC complex retention and the subsequent ICP-MS detection of Te. The method has been successfully applied to the tellurium speciation analysis in waters with spiked recoveries for Te(IV) and Te(VI) of 86.0-108% and 87.1-97.4%, respectively. (orig.)

  6. Ball Bearings Equipped for In Situ Lubrication on Demand

    Science.gov (United States)

    Marchetti, Mario; Jones, William R., Jr.; Pepper, Stephen V.; Jansen, Mark; Predmore, Roamer

    2005-01-01

    In situ systems that provide fresh lubricants to ball/race contacts on demand have been developed to prolong the operational lives of ball bearings. These systems were originally intended to be incorporated into ball bearings in mechanisms that are required to operate in outer space for years, in conditions in which lubricants tend to deteriorate and/or evaporate. These systems may also be useful for similarly prolonging bearing lifetimes on Earth. Reservoirs have been among the means used previously to resupply lubricants. Lubricant- resupply reservoirs are bulky and add complexity to bearing assemblies. In addition, such a reservoir cannot be turned on or off as needed: it supplies lubricant continuously, often leading to an excess of lubricant in the bearing. A lubricator of the present type includes a porous ring cartridge attached to the inner or the outer ring of a ball bearing (see Figure 1). Oil is stored in the porous cartridge and is released by heating the cartridge: Because the thermal expansion of the oil exceeds that of the cartridge, heating causes the ejection of some oil. A metal film can be deposited on a face of the cartridge to serve as an electrical-resistance heater. The heater can be activated in response to a measured increase in torque that signals depletion of oil from the bearing/race contacts. Because the oil has low surface tension and readily wets the bearing-ring material, it spreads over the bearing ring and eventually reaches the ball/race contacts. The Marangoni effect (a surface-tension gradient associated with a temperature gradient) is utilized to enhance the desired transfer of lubricant to the ball/race contacts during heating. For a test, a ball bearing designed for use at low speed was assembled without lubricant and equipped with a porous-ring lubricator, the resistance heater of which consumed a power of less than 1 W when triggered on by a torque-measuring device. In the test, a load of 20 lb (.89 N) was applied and the

  7. Magnetic Method for DNA Detection on an Arrayed Solid State Device

    National Research Council Canada - National Science Library

    Tamanaha, C. R; Colton, R. J; Miller, M. M; Piani, M. A; Rife, J. C; Sheehan, P. E; Whitman, L. J

    2001-01-01

    .... In addition to the electromagnetic instrumentation, surface chemistries and assays have been developed, as well as a cartridge-based microfluidics network in which pumps and valves are operated...

  8. Rigorous Mathematical Modeling of an Adsorption System With Electrothermal Regeneration of the Used Adsorbent

    National Research Council Canada - National Science Library

    Petkovska, Menka; Antov-Bozalo, Danijela; Nikacevic, Nikola

    2006-01-01

    The general objective of the project is fundamental mathematical modeling of a complex TSA system with electrothermal desorption step, with absorbers assembled of one or more cartridge-type, radial...

  9. 75 FR 70246 - Lead Fishing Sinkers; Disposition of TSCA Section 21 Petition

    Science.gov (United States)

    2010-11-17

    ...'s decision was based on the exclusion of shells and cartridges from the definition of ``chemical.... Kentucky Department of Fish & Wildlife Resources Tourism, Art and Heritage Cabinet. Letter to Honorable...

  10. 21 CFR 876.5600 - Sorbent regenerated dialysate delivery system for hemodialysis.

    Science.gov (United States)

    2010-04-01

    ... dialyzer. The device is used with the extracorporeal blood system and the dialyzer of the hemodialysis... dialysate conditions. The sorbent cartridge may include absorbent, ion exchange and catalytic materials. (b...

  11. THE THERAPEUTIC USE OF RADIOACTIVE GOLD SEEDS IN NEOPLASMS

    Energy Technology Data Exchange (ETDEWEB)

    Lachance, Paul; Vallee, A. F.

    1963-06-15

    A method and the apparatus for the treatment of neoplasms with Au/sup 198/ seeds are described. The introducer or gun is loaded with a magazine or cartridge containing 15 radioactive gold grains and then irradiated. The grains are cylinders made of gold encased in Pt with measurements of: length, 2.1 mm; diameter, 0.4 mm; weight, 25 mgm; platinum casing, 0.2 mm. The seeds are ready for use 7 to 10 days after irradiation or when gamma activity is around 3 to 4.5 mC per seed. A permanent implant gives to the tumor an approximate dose of 6000- 7000 r in 4 to 5 days. The effectiveness and advantages of the method are also discussed. (P.C.H.)

  12. Analysis characteristics determination of electrohydraulic control system operation to reduce the operation time of a powered roof support

    Science.gov (United States)

    Szurgacz, Dawid

    2018-01-01

    The article discusses basic functions of a powered roof support in a longwall unit. The support function is to provide safety by protecting mine workings against uncontrolled falling of rocks. The subject of the research includes the measures to shorten the time of roof support shifting. The roof support is adapted to transfer, in hazard conditions of rock mass tremors, dynamic loads caused by mining exploitation. The article presents preliminary research results on the time reduction of the unit advance to increase the extraction process and thus reduce operating costs. Conducted stand tests showed the ability to increase the flow for 3/2-way valve cartridges. The level of fluid flowing through the cartridges is adequate to control individual actuators.

  13. Spatial characterization of electrogram morphology from transmural recordings in the intact normal heart.

    Directory of Open Access Journals (Sweden)

    Jim Pouliopoulos

    Full Text Available PURPOSE: Unipolar (UE and bipolar electrograms (BE are utilized to identify arrhythmogenic substrate. We quantified the effect of increasing distance from the source of propagation on local electrogram amplitude; and determined if transmural electrophysiological gradients exist with respect to propagation and stimulation depth. METHODS: Mapping was performed on 5 sheep. Deployment of >50 quadripolar transmural needles in the LV were located in Cartesian space using Ensite. Contact electrograms from all needles were recorded during multisite bipolar pacing from epicardial then endocardial electrodes. Analysis was performed to determine stimulus distance to local activation time, peak negative amplitude (V-P, and peak-peak amplitude (VP-P for (1 unfiltered UE, and (2 unfiltered and 30 Hz high-pass filtered BEs. Each sheep was analysed using repeated ANOVA. RESULTS: Increasing distance from the pacing sites led to significant (p0.01 during endocardial stimulation, and 2.3±2.4 ms (UE and 1.8±3.7 ms (BE during epicardal stimulation (all pVP-P. Conduction propagates preferentially via the epicardium during stimulation and is believed to contribute to a transmural amplitude gradient.

  14. IX Disposition Project - project management plan

    International Nuclear Information System (INIS)

    Choi, I.G.

    1994-01-01

    This report presents plans for resolving saving and disposal concerns for ion exchange modules, cartridge filters and columns. This plan also documents the project baselines for schedules, cost, and technical information

  15. Capture, transport and husbandry of Naucrates ductor

    Directory of Open Access Journals (Sweden)

    Francisco De Vaissier Ferro Mauricio

    2014-06-01

    Full Text Available This is a report on the capture, transport, and husbandry of Naucrates ductor, also known as pilot fish. Approximately 100 individuals were collected by Flying Sharks in the sequence of an order from multiple public aquaria. Because there is vely limited knowledge about the capture, husbandry and transport of this species, it became necessary to investigate how to achieve this while causing minimum mortality and ensuring animal welfare. Collection was done in the Azores Islands, approximately 20 nautical miles from Horta, using a standard fishing rod and hook, after attracting blue sharks with bait. The animals were transported to shore inside plastic vats and introduced to large 2,0 m wide holding tanks at the Porto Pim Aquarium, where they were held for 2 months. Multiple treatments for wounds, and parasite control, were used and are reported. Transport to mainland Portugal was done aboard a commercial vessel, inside 2,4 m wide polyethylene vats with mechanical and chemical filtration consisting of cartridge filters and protein skimmers, respectively. Once docked on shore the 40 ft. container was then moved to a truck, where it traveled to Spain and France over 6 days. The total transport time of those animals delivered last was therefore 11 days and no mortalities were sustained in transit. The remaining animals were kept in Peniche for 2 more months inside 2,4 m wide polyethylene vats, with filtration consisting of cartridge and protein skimmers, as well as daily water changes. Multiple challenges faced during the collection, holding and transport processes are presented in this presentation.

  16. The preparation of albumin as a biological drug from human plasma by fiber filtration

    Directory of Open Access Journals (Sweden)

    Mousavi Hosseini K

    2011-08-01

    Full Text Available "nBackground: In recent years, consumption of whole-blood for the treatment of patients has decreased but use of biological plasma-derived medicines such as albumin, immunoglobulin and coagulation factors have increased instead. Paying attention to albumin molecular structure is important for its isolation from human plasma. Albumin is a single-chain protein consisting of about 585 amino acids and a molecular weight of 66500 Daltons. Albumin is a stable molecule and it is spherical in shape. There are different methods for human albumin preparation. Considering the large consumption of this biological drug in clinical settings, methods with fewer steps in production line are of big advantage in saving time and manufacturing more products."n "nMethods: In this project, we prepared human albumin using hollow fiber cartridges in order to omit the rework on fraction V+VI. Human albumin is usually produced by the application of cold ethanol method, where albumin is obtained from fraction V by doing a rework on fraction V+VI to separate fraction V."n "nResults: In the current work, human albumin was prepared from fraction V+VI by the help of hollow fiber cartridges. With a concentration of 20%, the obtained albumin had 96.5% of monomer and 3.5% of polymer and polymer aggregate."n "nConclusion: Comparing the obtained human albumin with a number of commercial human albumin samples by the use of SDS-page, the results were satisfactory regarding the 3.5 percent polymer and aggregate rate for the prepared albumin.

  17. Applying polarity rapid assessment method and ultrafiltration to characterize NDMA precursors in wastewater effluents.

    Science.gov (United States)

    Chen, Chao; Leavey, Shannon; Krasner, Stuart W; Mel Suffet, I H

    2014-06-15

    Certain nitrosamines in water are disinfection byproducts that are probable human carcinogens. Nitrosamines have diverse and complex precursors that include effluent organic matter, some anthropogenic chemicals, and natural (likely non-humic) substances. An easy and selective tool was first developed to characterize nitrosamine precursors in treated wastewaters, including different process effluents. This tool takes advantages of the polarity rapid assessment method (PRAM) and ultrafiltration (UF) (molecular weight distribution) to locate the fractions with the strongest contributions to the nitrosamine precursor pool in the effluent organic matter. Strong cation exchange (SCX) and C18 solid-phase extraction cartridges were used for their high selectivity for nitrosamine precursors. The details of PRAM operation, such as cartridge clean-up, capacity, pH influence, and quality control were included in this paper, as well as the main parameters of UF operation. Preliminary testing of the PRAM/UF method with effluents from one wastewater treatment plant gave very informative results. SCX retained 45-90% of the N-nitrosodimethylamine (NDMA) formation potential (FP)-a measure of the precursors-in secondary and tertiary wastewater effluents. These results are consistent with NDMA precursors likely having a positively charged amine group. C18 adsorbed 30-45% of the NDMAFP, which indicates that a substantial portion of these precursors were non-polar. The small molecular weight (MW) (10 kDa) fractions obtained from UF were the primary contributors to NDMAFP. The combination of PRAM and UF brings important information on the characteristics of nitrosamine precursors in water with easy operation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. 77 FR 11586 - Certain Toner Cartridges and Components Thereof

    Science.gov (United States)

    2012-02-27

    ...., Ltd., d/b/a Huebon Co., Limited, d/b/a Ink-Tank, 3/F, No. 1 Industrial Building, Pingdong 2 Road....V., Avenida del Parque 1175, Monterrey Technology Park, Cienega de Flores, Nuevo Leon, Mexico 65550...., 7611 Green Meadows Drive, Lewis Center, OH 43035. Discount Office Items, Inc., 302 Industrial Drive...

  19. Automated microfluidic cartridges for point-of-care cell counting

    CSIR Research Space (South Africa)

    Smith, S

    2016-10-01

    Full Text Available �PLFURIOXLGLF�FDUWULGJH�GHVLJQ� >�@�ZHUH�PDGH� WR�HQDEOH�DFFXUDWH�EORRG� VDPSOH�DQG�UHDJHQW�GLOXWLRQV�DQG�PL[LQJ�WR�EH�DFKLHYHG���)LJXUH���VKRZV�DQ�H[DPSOH�RI�WKH�LQMHFWLRQ� PROGHG�PLFURIOXLGLF�FDUWULGJH�ZLWK�EOLVWHU�SRXFKHV�XWLOL]HG�IRU�RQ�ERDUG�UHDJHQW�VWRUDJH��D���DV�ZHOO�DV� WKH�SRUWDEOH�VHW�XS...�����PL[LQJ�RI�VDPSOH�DQG�UHDJHQW��DQG����FKDPEHU�IRU�YLVXDOL]DWLRQ�DQG�FHOO�FRXQWLQJ����&DUWULGJH�GL� PHQVLRQV�� �����PP�î� �����PP�î� �PP�� �&DUWULGJHV� DQG� EOLVWHU� SRXFKHV�ZHUH�PDQXIDFWXUHG� E\\�PLFURIOXLGLF� &KLS6KRS�*PE+����E��'UDZLQJ�RI�SRUWDEOH�WHVW�VHW�XS�IRU�FRQWURO�DQG�WHVWLQJ�RI�PLFURIOXLGLF�FDUWULGJHV�� 978-0-9798064-9-0/µTAS 2016/$20©16CBMS...

  20. Development of a recovery method of {sup 131}I in the {sup 99}Mo process through the fission of 235{sup U}; Desenvolvimento de metodo de recuperacao de {sup 131}I no processo de producao de 99{sup M}o pela fissao de 2{sup 35}U

    Energy Technology Data Exchange (ETDEWEB)

    Bignardi, Aline Moraes Teixeira

    2013-07-01

    {sup 13}1{sup I} is an iodine radioisotope widely used in nuclear medicine that can be used either for diagnostic or for treatment due to its physical decay by {beta}{sup -} and its high emission of y-rays. It is produced at IPEN using the indirect reaction: {sup 130}Te(n,y){sup 131m}Te {yields} {sup 131}Te {yields} {sup 131}I where TeO{sub 2} targets are irradiated in a Nuclear Reactor. There is also the possibility of producing {sup 131}I by the fission of {sup 235}U, where about 300 different elements are produced together with {sup 131}I. The {sup 131}I produced through this method presents high specific activity and radioactive concentration suitable for the labeling of molecules. The aim of this work was to develop a recovery method of {sup 131}I with the required quality to be used in Nuclear Medicine in the {sup 99}Mo production process through the route of acid dissolution of metallic {sup 235}U targets. {sup 131}I can appear in two phases of the process, both in the gaseous phase produced during the dissolution of metallic U targets and in the dissolution solution. This work studied the recovery of {sup 131}I in these two phases. Several materials were used for the capture and recovery of {sup 131}I at the two phases of the process, the gaseous one and the solution of dissolution of U targets. Columns of alumina with Cu, acid alumina with Cu, Ag microspheres, Cu microspheres, Ag nanospheres, anionic cartridges, Ag cartridges, anion exchange resin and activated charcoal columns were tested. Solutions containing {sup 131}I in 0.1 mol.L{sup -1} NaOH were percolated through the materials and the eluted solutions were analyzed in a dose calibrator. The precipitation of AgI was also studied wth further dissolution of this precipitate with 0.1 mol L{sup -1} NH{sub 4}OH and 5% Na{sub 2}S{sub 2}O{sub 3}. The recovery results varied according to the material, activated charcoal showed recovery yields between 42% and 83% but the recovery yield of the alumina column

  1. Preparation and analysis of zero gases for the measurement of trace VOCs in air monitoring

    Science.gov (United States)

    Englert, Jennifer; Claude, Anja; Demichelis, Alessia; Persijn, Stefan; Baldan, Annarita; Li, Jianrong; Plass-Duelmer, Christian; Michl, Katja; Tensing, Erasmus; Wortman, Rina; Ghorafi, Yousra; Lecuna, Maricarmen; Sassi, Guido; Sassi, Maria Paola; Kubistin, Dagmar

    2018-06-01

    Air quality observations are performed globally to monitor the status of the atmosphere and its level of pollution and to assess mitigation strategies. Regulations of air quality monitoring programmes in various countries demand high-precision measurements for harmful substances often at low trace concentrations. These requirements can only be achieved by using high-quality calibration gases including high-purity zero gas. For volatile organic compound (VOC) observations, zero gas is defined as being hydrocarbon-free and can be, for example, purified air, nitrogen or helium. It is essential for the characterisation of the measurement devices and procedures, for instrument operation as well as for calibrations. Two commercial and one self-built gas purifiers were tested for their VOC removal efficiency following a standardised procedure. The tested gas purifiers included one adsorption cartridge with an inorganic media and two types of metal catalysts. A large range of VOCs were investigated, including the most abundant species typically measured at air monitoring stations. Both catalysts were able to remove a large range of VOCs whilst the tested adsorption cartridge was not suitable to remove light compounds up to C4. Memory effects occurred for the adsorption cartridge when exposed to higher concentration. This study emphasises the importance of explicitly examining a gas purifier for its intended application before applying it in the field.

  2. Fluidized bed coupled rotary reactor for nanoparticles coating via atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Chen-Long; Liu, Xiao; Chen, Rong, E-mail: rongchen@mail.hust.edu.cn, E-mail: bshan@mail.hust.edu.cn [State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, Hubei 430074 (China); Shan, Bin, E-mail: rongchen@mail.hust.edu.cn, E-mail: bshan@mail.hust.edu.cn [State Key Laboratory of Material Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan, Hubei 430074 (China)

    2015-07-15

    A fluidized bed coupled rotary reactor has been designed for coating on nanoparticles (NPs) via atomic layer deposition. It consists of five major parts: reaction chamber, dosing and fluidizing section, pumping section, rotary manipulator components, as well as a double-layer cartridge for the storage of particles. In the deposition procedure, continuous fluidization of particles enlarges and homogenizes the void fraction in the particle bed, while rotation enhances the gas-solid interactions to stabilize fluidization. The particle cartridge presented here enables both the fluidization and rotation acting on the particle bed, demonstrated by the analysis of pressure drop. Moreover, enlarged interstitials and intense gas–solid contact under sufficient fluidizing velocity and proper rotation speed facilitate the precursor delivery throughout the particle bed and consequently provide a fast coating process. The cartridge can ensure precursors flowing through the particle bed exclusively to achieve high utilization without static exposure operation. By optimizing superficial gas velocities and rotation speeds, minimum pulse time for complete coating has been shortened in experiment, and in situ mass spectrometry showed the precursor usage can reach 90%. Inductively coupled plasma-optical emission spectroscopy results suggested a saturated growth of nanoscale Al{sub 2}O{sub 3} films on spherical SiO{sub 2} NPs. Finally, the uniformity and composition of the shells were characterized by high angle annular dark field-transmission electron microscopy and energy dispersive X-ray spectroscopy.

  3. International Space Station (ISS) Emergency Mask (EM) Development

    Science.gov (United States)

    Toon, Katherine P.; Hahn, Jeffrey; Fowler, Michael; Young, Kevin

    2011-01-01

    The Emergency Mask (EM) is considered a secondary response emergency Personal Protective Equipment (PPE) designed to provide respiratory protection to the International Space Station (ISS) crewmembers in response to a post-fire event or ammonia leak. The EM is planned to be delivered to ISS in 2012 to replace the current air purifying respirator (APR) onboard ISS called the Ammonia Respirator (AR). The EM is a one ]size ]fits ]all model designed to fit any size crewmember, unlike the APR on ISS, and uses either two Fire Cartridges (FCs) or two Commercial Off-the-Shelf (COTS) 3M(Trademark). Ammonia Cartridges (ACs) to provide the crew with a minimum of 8 hours of respiratory protection with appropriate cartridge swap ]out. The EM is designed for a single exposure event, for either post ]fire or ammonia, and is a passive device that cannot help crewmembers who cannot breathe on their own. The EM fs primary and only seal is around the wearer fs neck to prevent a crewmember from inhaling contaminants. During the development of the ISS Emergency Mask, several design challenges were faced that focused around manufacturing a leak free mask. The description of those challenges are broadly discussed but focuses on one key design challenge area: bonding EPDM gasket material to Gore(Registered Trademark) fabric hood.

  4. High laboratory cost predicted per tuberculosis case diagnosed with increased case finding without a triage strategy.

    Science.gov (United States)

    Dunbar, R; Naidoo, P; Beyers, N; Langley, I

    2017-09-01

    Cape Town, South Africa. To model the effects of increased case finding and triage strategies on laboratory costs per tuberculosis (TB) case diagnosed. We used a validated operational model and published laboratory cost data. We modelled the effect of varying the proportion with TB among presumptive cases and Xpert cartridge price reductions on cost per TB case and per additional TB case diagnosed in the Xpert-based vs. smear/culture-based algorithms. In our current scenario (18.3% with TB among presumptive cases), the proportion of cases diagnosed increased by 8.7% (16.7% vs. 15.0%), and the cost per case diagnosed increased by 142% (US$121 vs. US$50). The cost per additional case diagnosed was US$986. This would increase to US$1619 if the proportion with TB among presumptive cases was 10.6%. At 25.9-30.8% of TB prevalence among presumptive cases and a 50% reduction in Xpert cartridge price, the cost per TB case diagnosed would range from US$50 to US$59 (comparable to the US$48.77 found in routine practice with smear/culture). The operational model illustrates the effect of increased case finding on laboratory costs per TB case diagnosed. Unless triage strategies are identified, the approach will not be sustainable, even if Xpert cartridge prices are reduced.

  5. EffiCiency and Safety of an eLectronic cigAreTte (ECLAT as tobacco cigarettes substitute: a prospective 12-month randomized control design study.

    Directory of Open Access Journals (Sweden)

    Pasquale Caponnetto

    Full Text Available Electronic cigarettes (e-cigarettes are becoming increasingly popular with smokers worldwide. Users report buying them to help quit smoking, to reduce cigarette consumption, to relieve tobacco withdrawal symptoms, and to continue having a 'smoking' experience, but with reduced health risks. Research on e-cigarettes is urgently needed in order to ensure that the decisions of regulators, healthcare providers and consumers are based on science. Methods ECLAT is a prospective 12-month randomized, controlled trial that evaluates smoking reduction/abstinence in 300 smokers not intending to quit experimenting two different nicotine strengths of a popular e-cigarette model ('Categoria'; Arbi Group Srl, Italy compared to its non-nicotine choice. GroupA (n = 100 received 7.2 mg nicotine cartridges for 12 weeks; GroupB (n = 100, a 6-week 7.2 mg nicotine cartridges followed by a further 6-week 5.4 mg nicotine cartridges; GroupC (n = 100 received no-nicotine cartridges for 12 weeks. The study consisted of nine visits during which cig/day use and exhaled carbon monoxide (eCO levels were measured. Smoking reduction and abstinence rates were calculated. Adverse events and product preferences were also reviewed.Declines in cig/day use and eCO levels were observed at each study visits in all three study groups (p<0.001 vs baseline, with no consistent differences among study groups. Smoking reduction was documented in 22.3% and 10.3% at week-12 and week-52 respectively. Complete abstinence from tobacco smoking was documented in 10.7% and 8.7% at week-12 and week-52 respectively. A substantial decrease in adverse events from baseline was observed and withdrawal symptoms were infrequently reported during the study. Participants' perception and acceptance of the product under investigation was satisfactory.In smokers not intending to quit, the use of e-cigarettes, with or without nicotine, decreased cigarette consumption and elicited enduring tobacco

  6. 40 CFR 721.5700 - Pentanenitrile, 3-amino-.

    Science.gov (United States)

    2010-07-01

    ...), (a)(5)(xiii), (a)(5)(xiv), and (a)(5)(xv) apply following submittal by the company, and written approval by the EPA, of the results of cartridge service life testing performance in accordance with...

  7. Reliability analysis of GEM® Premier™ technology: a multicenter study

    Directory of Open Access Journals (Sweden)

    Francesco Faggiano

    2015-10-01

    Full Text Available This paper describes how specific blood gas analyzer characteristics can support the emerging clinical and organizational user’s needs while ensuring patient safety. A oneyear data set from two Italian hospitals was analyzed from 10 different blood gas analyzers. Performance measurements in terms of mean down time (MDT were calculated to show how technical characteristics declared by the manufacturer compare to the analyzer availability in real clinical settings. Results show a high level of reliability for the analyzed technology, associated with very low MDT of each sensor integrated in the cartridge. Moreover, results show a high level of efficiency in cartridge usage. Such results are consistent with the specification of the GEM® Premier™ maintenance- free technology and are particularly relevant in the point-of-care testing setting.

  8. Controlled blasting experiments in a small drift at the CANMET experimental mine

    Energy Technology Data Exchange (ETDEWEB)

    Lizotte, Y.C.

    1994-03-01

    Experiments on controlled blasting conducted at the CANMET Experimental Mine to develop suitable controlled blasting techniques for small development headings are described. The methods selected for study must maintain the drill-blast-muck cycle achieved each work shift. The experiments also examine blast damage mechanisms to formulate criteria for dilution minimization with blast designs in stopes. The drift faces are 2.4 m square, with 34 to 43 holes drilled 2.4 m deep. Cartridged water gels, emulsions, and semi-gelatin dynamite were used in the cuts and as primers, ANFO as the main explosive, and semi- gelatin dynamite in 19 mm diameter cartridges was used in perimeter holes. The results of the first set of experiments show the efficiency of controlled blasting techniques to reduce blast damage. 60 refs., 71 figs., 9 tabs.

  9. Surface deposition measurements of the TMI-2 gross decontamination experiment

    International Nuclear Information System (INIS)

    McIssac, C.V.; Hetzer, D.C.

    1982-01-01

    In order to measure the effectiveness of the gross decontamination experiment (principally a water spray technique) performed in the TMI-2 reactor building, the Technical Information and Examination Program's Radiation and Environment personnel made surface activity measurements before and after the experiment. In conjunction with surface sampling, thermoluminescent dosimeter (TLD) and gamma spectrometry measurements were also performed to distinguish between radiation fields and contamination. The surface sampler used to collect samples from external surfaces within the reactor building is a milling tool having four major components: a 1.27-cm constant-speed drill; a drill support assembly that allows setting sample penetration depth; filter cartridges for intake air purification and sample collection; and an air pump that forces air across the surface being sampled and through the sample filter cartridge

  10. Travelers' Health: Cryptosporidiosis

    Science.gov (United States)

    ... associated diarrhea; cryptosporidiosis was associated with travel to Asia, particularly India, and Latin America. Another study found ... immunochromatographic cartridge assays, and microscopy with modified acid-fast staining. ... and water precautions (see Chapter 2, Food & Water ...

  11. Nicotine and tobacco

    Science.gov (United States)

    ... ease your withdrawal symptoms. Health experts warn that e-cigarettes are not a replacement therapy for cigarette smoking. ... not known exactly how much nicotine is in e-cigarette cartridges, because information on labels is often wrong.

  12. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  13. Application of cation-exchange solid-phase extraction for the analysis of amino alcohols from water and human plasma for verification of Chemical Weapons Convention.

    Science.gov (United States)

    Kanaujia, Pankaj K; Tak, Vijay; Pardasani, Deepak; Gupta, A K; Dubey, D K

    2008-03-28

    The analysis of nitrogen containing amino alcohols, which are the precursors and degradation products of nitrogen mustards and nerve agent VX, constitutes an important aspect for verifying the compliance to the CWC (Chemical Weapons Convention). This work devotes on the development of solid-phase extraction method using silica- and polymer-based SCX (strong cation-exchange) and MCX (mixed-mode strong cation-exchange) cartridges for N,N-dialkylaminoethane-2-ols and alkyl N,N-diethanolamines, from water. The extracted analytes were analyzed by GC-MS (gas chromatography-mass spectrometry) in the full scan and selected ion monitoring modes. The extraction efficiencies of SCX and MCX cartridges were compared, and results revealed that SCX performed better. Extraction parameters, such as loading capacity, extraction solvent, its volume, and washing solvent were optimized. Best recoveries were obtained using 2 mL methanol containing 10% NH(4)OH and limits of detection could be achieved up to 5 x 10(-3) microg mL(-1) in the selected ion monitoring mode and 0.01 microg mL(-1) in full scan mode. The method was successfully employed for the detection and identification of amino alcohol present in water sample sent by Organization for Prohibition of Chemical Weapons (OPCW) in the official proficiency tests. The method was also applied to extract the analytes from human plasma. The SCX cartridge showed good recoveries of amino alcohols from human plasma after protein precipitation.

  14. Experience with high-temperature filtration of incinerator flue gases

    International Nuclear Information System (INIS)

    Carpentier, S.; de Tassigny, C.

    1990-01-01

    It is always preferable to filter incinerator flue gases as close as possible to their origin, i.e. in a high-temperature zone, and means must be provided to destroy the other organic parts of the flyash resulting from these gases by in-filter combustion. The filter also traps a mineral part of the flyash, which eventually causes clogging and requires replacement or regeneration. Such filtration systems are available and can be operated on an industrial scale. They include candles made of micro-expanded refractory alloys supporting filtering media, porous ceramic candles and other devices. Research and subsequent pilot facility testing have enabled development of alumina fiber filter cartridges that offer more advantages than other equipment employed to date. Specifically, these advantages are: ultralight weight, which enables construction of systems that are relatively unaffected by creep and high-temperature deformations; excellent refractory qualities, which permit a use above 1000 degrees C; insensitivity to thermal shocks and in-situ carbon fines combustion capability; anti-acid quality of the material, which enables high-temperature filtration of acidic flue gases (chlorine and hydrochloric acid, SO x , etc.); low initial pressure drop of the cartridges; dimensional stability of the cartridges, which can be machined to a given tolerance with specific contours after casting and drying. This paper reports the results obtained during the last filtration system test campaign. Details are given for operating conditions, grain sizes and real-time monitoring of various parameters

  15. Field selection of chemical protective clothing and respiratory protection

    International Nuclear Information System (INIS)

    Pinette, S.; Dodgen, C.; Morley, M.

    1991-01-01

    Safety professionals who must choose appropriate personal protective equipment for hazardous substance response or hazardous waste sites require useable information about the effectiveness of the various products available. Each hazardous waste operation involves a unique combination of chemical hazards requiring a unique combination of protective apparel. A chemical protective suit or respirator must be chosen for each site and each operation on the site. No single protective suit is effective against all chemical hazards. No single respirator is the best choice in every situation. Various sources of information on the effectiveness of protective clothing products will be discussed. Site-specific permeation testing of the proposed protective clothing options will also be discussed. It is both possible and practical to obtain specific information about the degree of protection afforded by a particular suit against a particular chemical mixture. It is also important to know how long the suit will last. Choosing adequate respiratory protection is a complex process. Respirator cartridge performance depends on various environmental factors as well as upon the combination and concentration of chemicals in the air. Once characterization of the air at a site has been accomplished, it may be appropriate to select an alternative to airline respirators and SCBAs. Respirator cartridges can be tested against specific chemical mixtures using worse case environmental factors. The results can be used to predict both the effectiveness and duration of protection afforded by respirator cartridges which can reduce costs and worker fatigue

  16. Comparison of solid phase extraction, saponification and gel permeation chromatography for the clean-up of microwave-assisted biological extracts in the analysis of polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Navarro, P; Cortazar, E; Bartolomé, L; Deusto, M; Raposo, J C; Zuloaga, O; Arana, G; Etxebarria, N

    2006-09-22

    The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.

  17. Raman spectroscopy and capillary electrophoresis applied to forensic colour inkjet printer inks analysis.

    Science.gov (United States)

    Król, Małgorzata; Karoly, Agnes; Kościelniak, Paweł

    2014-09-01

    Forensic laboratories are increasingly engaged in the examination of fraudulent documents, and what is important, in many cases these are inkjet-printed documents. That is why systematic approaches to inkjet printer inks comparison and identification have been carried out by both non-destructive and destructive methods. In this study, micro-Raman spectroscopy and capillary electrophoresis (CE) were applied to the analysis of colour inkjet printer inks. Micro-Raman spectroscopy was used to study the chemical composition of colour inks in situ on a paper surface. It helps to characterize and differentiate inkjet inks, and can be used to create a spectra database of inks taken from different cartridge brands and cartridge numbers. Capillary electrophoresis in micellar electrophoretic capillary chromatography mode was applied to separate colour and colourless components of inks, enabling group identification of those components which occur in a sufficient concentration (giving intensive peaks). Finally, on the basis of the obtained results, differentiation of the analysed inks was performed. Twenty-three samples of inkjet printer inks were examined and the discriminating power (DP) values for both presented methods were established in the routine work of experts during the result interpretation step. DP was found to be 94.0% (Raman) and 95.6% (CE) when all the analysed ink samples were taken into account, and it was 96.7% (Raman) and 98.4% (CE), when only cartridges with different index numbers were considered. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Assessment of an automated capillary system for Plasmodium vivax microsatellite genotyping.

    Science.gov (United States)

    Manrique, Paulo; Hoshi, Mari; Fasabi, Manuel; Nolasco, Oscar; Yori, Pablo; Calderón, Martiza; Gilman, Robert H; Kosek, Margaret N; Vinetz, Joseph M; Gamboa, Dionicia

    2015-08-21

    Several platforms have been used to generate the primary data for microsatellite analysis of malaria parasite genotypes. Each has relative advantages but share a limitation of being time- and cost-intensive. A commercially available automated capillary gel cartridge system was assessed in the microsatellite analysis of Plasmodium vivax diversity in the Peruvian Amazon. The reproducibility and accuracy of a commercially-available automated capillary system, QIAxcel, was assessed using a sequenced PCR product of 227 base pairs. This product was measured 42 times, then 27 P. vivax samples from Peruvian Amazon subjects were analyzed with this instrument using five informative microsatellites. Results from the QIAxcel system were compared with a Sanger-type sequencing machine, the ABI PRISM(®) 3100 Genetic Analyzer. Significant differences were seen between the sequenced amplicons and the results from the QIAxcel instrument. Different runs, plates and cartridges yielded significantly different results. Additionally, allele size decreased with each run by 0.045, or 1 bp, every three plates. QIAxcel and ABI PRISM systems differed in giving different values than those obtained by ABI PRISM, and too many (i.e. inaccurate) alleles per locus were also seen with the automated instrument. While P. vivax diversity could generally be estimated using an automated capillary gel cartridge system, the data demonstrate that this system is not sufficiently precise for reliably identifying parasite strains via microsatellite analysis. This conclusion reached after systematic analysis was due both to inadequate precision and poor reproducibility in measuring PCR product size.

  19. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium

    International Nuclear Information System (INIS)

    Nakao, Ryuji; Halldin, Christer

    2013-01-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. Methods: This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Results: Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for 11 C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Conclusion: Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma

  20. Organic carbon movement through two SWRO facilities from source water to pretreatment to product with relevance to membrane biofouling

    KAUST Repository

    Alshahri, Abdullah; Dehwah, Abdullah; Leiknes, TorOve; Missimer, Thomas M.

    2016-01-01

    reductions. The mixed media filtration process was marginally useful in removing some TOC and NOM, but had little effect on TEP removal. Some bacterial regrowth may be occurring in the cartridge filters, but the evidence is inconsistent. Significant

  1. Iodine removal adsorbent histories, aging and regeneration

    International Nuclear Information System (INIS)

    Hunt, J.R.; Rankovic, L.; Lubbers, R.; Kovach, J.L.

    1976-01-01

    The experience of efficiency changes with life under various test conditions is described. The adsorbents were periodically removed from both standby and continuously operating systems and tested under various test methods for residual iodine adsorption efficiency. Adsorbent from several conventional ''sampler'' cartridges versus the bulk adsorbent was also tested showing deficiency in the use of cartridge type sampling. Currently required test conditions were found inadequate to follow the aging of the adsorbent because pre-equilibration of the sample acts as a regenerant and the sample is not tested in the ''as is'' condition. The most stringent test was found to be the ambient temperature, high humidity test to follow the aging of the adsorbent. Several methods were evaluated to regenerate used adsorbents; of these high temperature steaming and partial reimpregnation were found to produce adsorbents with near identical properties of freshly prepared adsorbents

  2. Método colorimétrico para determinação de dióxido de nitrogênio atmosférico com preconcentração em coluna de c-18

    Directory of Open Access Journals (Sweden)

    Ugucione Cássia

    2002-01-01

    Full Text Available An alternative analytical method for nitrogen dioxide (NO2 in atmosphere was developed. The collection of NO2 is performed by a Sep-Pack C-18 cartridge impregnated with 11% (v/v of triethanolamine plus 3,6 % (v/v of ethylene glycol plus 25 % (v/v of acetone combined solution. When the impregnating is used, NO2 is collected with good repeatibility (CV = 3,3 %. The NO2 absorbed in the sampler was stripped from the sorbent with a methanol 5% (v/v aqueous solution and was determined by colorimetry as nitrite by using the Griess-Saltzman reagent. The detection limit of 1,4 ppb for 60 min sampling at 0,5 L min-1 flow rate was obtained. Preparation and conditioning procedures for TEA-C-18 cartridge, sampling flow rate, absorption capacity and interference of other species are discussed.

  3. General and selective isolation procedure for high-performance liquid chromatographic determination of anabolic steroids in tissues.

    Science.gov (United States)

    Laganà, A; Marino, A

    1991-12-27

    A multi-residue method has been developed for the determination of anabolic steroids in animal tissue. The analytes are extracted from tissue with methanol and the extract is subjected to two solid-phase extractions, one using a non-specific adsorbing material, such as graphitized carbon black (Carbopack B), and the other Amberlite CG-400 I in the OH form. This procedure allowed the neutral anabolics (testosterone, trenbolone and progesterone) to be isolated and separated from the acidic type (phenolic group), such as diethylstilbestrol, oestradiol, zeranol/zearalenone and their respective metabolites. The determination was effected using high-performance liquid chromatography with different detectors (ultraviolet, fluorimetric and electrochemical). Several analytical parameters were studied: chromatographic conditions, recoveries, evaporation step, solvent flow-rate, cartridges reusability, interference of plastic cartridges. For all the anabolics investigated the recoveries were greater than 83.6%.

  4. A solid-phase extraction method for rapidly determining the adsorption coefficient of pharmaceuticals in sewage sludge

    Science.gov (United States)

    Berthod, Laurence; Roberts, Gary; Whitley, David C.; Sharpe, Alan; Mills, Graham A.

    2014-01-01

    The partitioning of pharmaceuticals in the environment can be assessed by measuring their adsorption coefficients (Kd) between aqueous and solid phases. Measuring this coefficient in sewage sludge gives an indication of their partitioning behaviour in a wastewater treatment plant and hence contributes to an understanding of their subsequent fate. The regulatory approved method for measuring Kd in sewage sludge is the US Environmental Protection Agency's Office of Prevention, Pesticides and Toxic Substances (OPPTS) guideline 835.1110, which is labour intensive and time consuming. We describe an alternative method for measuring the Kd of pharmaceuticals in sewage sludge using a modified solid-phase extraction (SPE) technique. SPE cartridges were packed at different sludge/PTFE ratios (0.4, 6.0, 24.0 and 40.0% w/w sludge) and eluted with phosphate buffer at pH 7.4. The approach was tested initially using three pharmaceuticals (clofibric acid, diclofenac and oxytetracycline) that covered a range of Kd values. Subsequently, the sorption behaviour of ten further pharmaceuticals with varying physico-chemical properties was evaluated. Results from the SPE method were comparable to those of the OPPTS test, with a correlation coefficient of 0.93 between the two approaches. SPE cartridges packed with sludge and PTFE were stable for up to one year; use within one month reduced variability in measurements (to a maximum of 0.6 log units). The SPE method is low-cost, easy to use and enables the rapid measurement of Kd values for a large number of chemicals. It can be used as an alternative to the more laborious full OPPTS test in environmental fate studies and risk assessments. PMID:25299795

  5. 76 FR 9555 - Procurement List; Additions and Deletions

    Science.gov (United States)

    2011-02-18

    ...-8067--Inkjet printer cartridge. NPA: Alabama Industries for the Blind, Talladega, AL. Contracting... Services Administration, New York, NY. Service Service Type/Location: Eyewear Prescription Service...: Winston-Salem Industries for the Blind, Inc., Winston- Salem, NC. Contracting Activity: Department of...

  6. Use of beach galleries as an intake for future seawater desalination facilities in Florida and globally similar areas

    KAUST Repository

    Missimer, Thomas M.; Maliva,, Robert G.; Dehwah, Abdullah; Phelps, Daniel

    2013-01-01

    by the pretreatment system and they pass through the cartridge filters into the membranes, thereby causing frequent and expensive cleaning of the membranes. Quality of the raw water can be greatly improved by the use of subsurface intakes which can substantially

  7. Griswold Tempered Water Flow Regulator Valves Used as Anti-Siphon Valves

    International Nuclear Information System (INIS)

    MISKA, C.

    2000-01-01

    FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus

  8. Modeling and numerical simulation of interior ballistic processes in a 120mm mortar system

    Science.gov (United States)

    Acharya, Ragini

    Numerical Simulation of interior ballistic processes in gun and mortar systems is a very difficult and interesting problem. The mathematical model for the physical processes in the mortar systems consists of a system of non-linear coupled partial differential equations, which also contain non-homogeneity in form of the source terms. This work includes the development of a three-dimensional mortar interior ballistic (3D-MIB) code for a 120mm mortar system and its stage-wise validation with multiple sets of experimental data. The 120mm mortar system consists of a flash tube contained within an ignition cartridge, tail-boom, fin region, charge increments containing granular propellants, and a projectile payload. The ignition cartridge discharges hot gas-phase products and unburned granular propellants into the mortar tube through vent-holes on its surface. In view of the complexity of interior ballistic processes in the mortar propulsion system, the overall problem was solved in a modular fashion, i.e., simulating each physical component of the mortar propulsion system separately. These modules were coupled together with appropriate initial and boundary conditions. The ignition cartridge and mortar tube contain nitrocellulose-based ball propellants. Therefore, the gas dynamical processes in the 120mm mortar system are two-phase, which were simulated by considering both phases as an interpenetrating continuum. Mass and energy fluxes from the flash tube into the granular bed of ignition cartridge were determined from a semi-empirical technique. For the tail-boom section, a transient one-dimensional two-phase compressible flow solver based on method of characteristics was developed. The mathematical model for the interior ballistic processes in the mortar tube posed an initial value problem with discontinuous initial conditions with the characteristics of the Riemann problem due to the discontinuity of the initial conditions. Therefore, the mortar tube model was solved

  9. The NxStage System One.

    Science.gov (United States)

    Clark, William R; Turk, Joseph E

    2004-01-01

    Given the results of recent randomized controlled trials as well as staffing and budget challenges that today face many institutions across North America, a novel therapeutic approach is likely necessary to enable improvements in clinical outcomes for renal failure patients. The NxStage System One was developed to address these challenges. The system is an innovative, flexible device that delivers hemodialysis, hemofiltration, and/or ultrafiltration therapies to patients with renal failure or fluid overload. The unique characteristics of this system include a highly automated system design with a drop-in cartridge to facilitate training and simple operation; portable size and independence from dedicated infrastructure to minimize practical barriers to where therapy may be administered; use of high-quality premixed treatment fluids to enable capture of the potential clinical benefits of fluid purity without the hassles of local water treatment; and wide operating ranges to allow clinician flexibility in patient therapy prescriptions. In both the chronic and acute care environments, the System One presents clinicians with a new platform for delivering patient therapy improvements within real-world constraints.

  10. Personality does not predict treatment preference, treatment experience does: a study of four complementary pain treatments.

    Science.gov (United States)

    Blasche, Gerhard; Melchart, Herbert; Leitner, Daniela; Marktl, Wolfgang

    2007-10-01

    The aim of the present study was to determine the extent to which personality and treatment experience affect patients' appraisals of 4 complementary treatments for chronic pain. A total of 232 chronic pain patients (164 females, 68 males, average age 56.6 years) visiting a spa clinic in Austria returned a questionnaire on patient characteristics and personality (autonomy, depressiveness, assertiveness, self-control) as well as attitudes towards (i.e. appealing, effective, pleasant) and experience of the treatments. Results were analysed by use of linear regression analysis and confidence intervals. Although all treatments were appraised positively, the passive treatments (thermal water tub baths, classical massage) were favoured more than the active treatments (relaxation training or exercise therapy). Treatment appraisal was not predicted by any of the personality traits but to a large extent by treatment experience. Relaxing, not unpleasant treatments were the most highly esteemed treatments. How strenuous or tiring a treatment was only had a minor effect on its appraisal. Neither do dependent, passive patients prefer passive treatments, nor do conscientious patients prefer active treatments. Instead, the appraisal of treatments that induce specific somatosensory sensations is largely determined by treatment experiences, i.e. what the treatment feels like. Despite the popularity of CAM which encompasses many experientially intensive treatments, treatment experience has to date been a neglected topic of treatment research.

  11. Effect of Medium Supplements on Agrobacterium rhizogenes Mediated Hairy Root Induction from the Callus Tissues of Camellia sinensis var. sinensis.

    Science.gov (United States)

    Rana, Mohammad M; Han, Zhuo-Xiao; Song, Da-Peng; Liu, Guo-Feng; Li, Da-Xiang; Wan, Xiao-Chun; Karthikeyan, Alagarsamy; Wei, Shu

    2016-07-15

    Tea (Camellia sinensis L.) is recalcitrant to Agrobacterium-mediated genetic transformation largely due to the bactericidal effects of tea polyphenols and phenolics oxidation induced by necrosis of explant tissue over the process of transformation. In this study, different antioxidants/adsorbents were added as supplements to the co-cultivation and post co-cultivation media to overcome these problems for the transformation improvement. Tea-cotyledon-derived calli were used as explants and Agrobacterium rhizognes strain ATCC 15834 was used as a mediator. Results showed that Agrobacterium growth, virulence (vir) gene expression and browning of explant tissue were greatly influenced by different supplements. Murashige and Skoog (MS) basal salts medium supplemented with 30 g·L(-1) sucrose, 0.1 g·L(-1) l-glutamine and 5 g·L(-1) polyvinylpolypyrrolidone (PVPP) as co-cultivation and post co-cultivation media could maintain these parameters better that ultimately led to significant improvement of hairy root generation efficiency compared to that in the control (MS + 30 g·L(-1) sucrose). Additionally, the reporter genes β-glucuronidase (gusA) and cyan fluorescent protein (cfp) were also stably expressed in the transgenic hairy roots. Our study would be helpful in establishing a feasible approach for tea biological studies and genetic improvement of tea varieties.

  12. Effect of Medium Supplements on Agrobacterium rhizogenes Mediated Hairy Root Induction from the Callus Tissues of Camellia sinensis var. sinensis

    Directory of Open Access Journals (Sweden)

    Mohammad M. Rana

    2016-07-01

    Full Text Available Tea (Camellia sinensis L. is recalcitrant to Agrobacterium-mediated genetic transformation largely due to the bactericidal effects of tea polyphenols and phenolics oxidation induced by necrosis of explant tissue over the process of transformation. In this study, different antioxidants/adsorbents were added as supplements to the co-cultivation and post co-cultivation media to overcome these problems for the transformation improvement. Tea-cotyledon-derived calli were used as explants and Agrobacterium rhizognes strain ATCC 15834 was used as a mediator. Results showed that Agrobacterium growth, virulence (vir gene expression and browning of explant tissue were greatly influenced by different supplements. Murashige and Skoog (MS basal salts medium supplemented with 30 g·L−1 sucrose, 0.1 g·L−1 l-glutamine and 5 g·L−1 polyvinylpolypyrrolidone (PVPP as co-cultivation and post co-cultivation media could maintain these parameters better that ultimately led to significant improvement of hairy root generation efficiency compared to that in the control (MS + 30 g·L−1 sucrose. Additionally, the reporter genes β-glucuronidase (gusA and cyan fluorescent protein (cfp were also stably expressed in the transgenic hairy roots. Our study would be helpful in establishing a feasible approach for tea biological studies and genetic improvement of tea varieties.

  13. Determination of a wide range of volatile organic compounds in ambient air using multisorbent adsorption/thermal desorption and gas chromatography/mass spectrometry

    Science.gov (United States)

    Pankow, J.F.; Luo, W.; Isabelle, L.M.; Bender, D.A.; Baker, R.J.

    1998-01-01

    Adsorption/thermal desorption with multisorbent air-sampling cartridges was developed for the determination of 87 method analytes including halogenated alkanes, halogenated alkenes, ethers, alcohols, nitriles, esters, ketones, aromatics, a disulfide, and a furan. The volatilities of the compounds ranged from that of dichlorofluoromethane (CFC12) to that of 1,2,3- trichlorobenzene. The eight most volatile compounds were determined using a 1.5-L air sample and a sample cartridge containing 50 mg of Carbotrap B and 280 mg of Carboxen 1000; the remaining 79 compounds were determined using a 5-L air sample and a cartridge containing 180 mg of Carbotrap B and 70 mg of Carboxen 1000. Analysis and detection were by gas chromatography/mass spectrometry. The minimum detectable level (MDL) concentration values ranged from 0.01 parts per billion by volume (ppbv) for chlorobenzene to 0.4 ppbv for bromomethane; most of the MDL values were in the range 0.02-0.06 ppbv. No breakthrough was detected with the prescribed sample volumes. Analyte stability on the cartridges was very good. Excellent recoveries were obtained with independent check standards. Travel spike recoveries ranged from 90 to 110% for 72 of the 87 compounds. The recoveries were less than 70% for bromomethane and chloroethene and for a few compounds such as methyl acetate that are subject to losses by hydrolysis; the lowest travel spike recovery was obtained for bromomethane (62%). Blank values for all compounds were either below detection or very low. Ambient atmospheric sampling was conducted in New Jersey from April to December, 1997. Three sites characterized by low, moderate, and high densities of urbanization/traffic were sampled. The median detected concentrations of the compounds were either similar at all three sites (as with the chlorofluorocarbon compounds) or increased with the density of urbanization/traffic (as with dichloromethane, MTBE, benzene, and toluene). For toluene, the median detected

  14. Imaging assessment of a portable hemodialysis device: detection of possible failure modes and monitoring of functional performance.

    Science.gov (United States)

    Olorunsola, Olufoladare G; Kim, Steven H; Chang, Ryan; Kuo, Yuo-Chen; Hetts, Steven W; Heller, Alex; Kant, Rishi; Saeed, Maythem; Fissell, William H; Roy, Shuvo; Wilson, Mark W

    2014-03-27

    The purpose of this study was to investigate the utility and limitations of various imaging modalities in the noninvasive assessment of a novel compact hemodialyzer under development for renal replacement therapy, with specific aim towards monitoring its functional performance. The prototype is a 4×3×6 cm aluminum cartridge housing "blood" and "dialysate" flow paths arranged in parallel. A sheet of semipermeable silicon nanopore membranes forms the blood-dialysate interface, allowing passage of small molecules. Blood flow was simulated using a peristaltic pump to instill iodinated contrast through the blood compartment, while de-ionized water was instilled through the dialysate compartment at a matched rate in the countercurrent direction. Images were acquired under these flow conditions using multi-detector computed tomography (MDCT), fluoroscopy, high-resolution quantitative computed tomography (HR-QCT), and magnetic resonance imaging (MRI). MDCT was used to monitor contrast diffusion efficiency by plotting contrast density as a function of position along the path of flow through the cartridge during steady state infusion at 1 and 20 mL/min. Both linear and exponential regressions were used to model contrast decay along the flow path. Both linear and exponential models of contrast decay appeared to be reasonable approximations, yielding similar results for contrast diffusion during a single pass through the cartridge. There was no measurable difference in contrast diffusion when comparing 1 mL/min and 20 mL/min flow rates. Fluoroscopy allowed a gross qualitative assessment of flow within the device, and revealed flow inhomogeneity within the corner of the cartridge opposite the blood inlet port. MRI and HR-QCT were both severely limited due to the paramagnetic properties and high atomic number of the target material, respectively. During testing, we encountered several causes of device malfunction, including leak formation, trapped gas, and contrast

  15. Nicotine content of electronic cigarettes, its release in vapour and its consistency across batches: regulatory implications.

    Science.gov (United States)

    Goniewicz, Maciej L; Hajek, Peter; McRobbie, Hayden

    2014-03-01

    Electronic cigarettes (EC) may have a potential for public health benefit as a safer alternative to smoking, but questions have been raised about whether EC should be licensed as a medicine, with accurate labelling of nicotine content. This study determined the nicotine content of the cartridges of the most popular EC brands in the United Kingdom and the nicotine levels they deliver in the vapour, and estimated the safety and consistency of nicotine delivery across batches of the same product as a proxy for quality control for individual brands and within the industry. We studied five UK brands (six products) with high internet popularity. Two samples of each brand were purchased 4 weeks apart, and analysed for nicotine content in the cartridges and nicotine delivery in vapour. The nicotine content of cartridges within the same batch varied by up to 12% relative standard deviation (RSD) and the mean difference between different batches of the same brand ranged from 1% [95% confidence interval (CI) = -5 to 7%] to 20% (95% CI=14-25%) for five brands and 31% (95% CI=21-39%) for the sixth. The puffing schedule used in this study vaporized 10-81% of the nicotine present in the cartridges. The nicotine delivery from 300 puffs ranged from ∼2 mg to ∼15 mg and was not related significantly to the variation of nicotine content in e-liquid (r=0.06, P=0.92). None of the tested products allowed access to e-liquid or produced vapour nicotine concentrations as high as conventional cigarettes. There is very little risk of nicotine toxicity from major electronic cigarette (EC) brands in the United Kingdom. Variation in nicotine concentration in the vapour from a given brand is low. Nicotine concentration in e-liquid is not well related to nicotine in vapour. Other EC brands may be of lower quality and consumer protection regulation needs to be implemented, but in terms of accuracy of labelling of nicotine content and risks of nicotine overdose, regulation over and above

  16. Labeling Lanreotide with 125I and 188Re. China

    International Nuclear Information System (INIS)

    Bai Hongsheng

    2000-01-01

    Lanreotide (D-β-Nal-Cys-Try-D-Trp-Lys-Val-Cys-Thr-NH2) is a new somatostatin analogue. It can bind to human somatostatin receptor (hSSTR) subtype 2 through 5 with high affinity and to hSSTR subtype 1 with low affinity. We investigate labeling condition, quality control and stability in vitro of 125 I-Lanreotide and 188 Re-lanreotide respectively. (A) Lanreotide is labeled with 125 I using Chloramine T. The effect of reaction condition (such as reaction time, pH value, Lanreotide amount, quantity of Chloramine T and reaction volume) on labeling yield is investigated in detail. (B) The labeling yield and radiochemical purity (RP) is measured with paper chromatography (PC) and Sep-Pak C 18 Cartridge. For PC method, 125 I-Lanreotide is spotted on the Whatman No.1 paper and developed in the mixture of CH 3 CH 2 CH 2 CH 2 OH and CH 3 CH 2 OH and NH 4 OH (v/v/v=5:2:1), the Rf value of every component in the mobile phase is given in table 1. For Sep-Pak C 18 Cartridge methods each cartridge is washed with 10 ml of ethanol followed by 10 ml of iso-CH 3 CH 2 CH 2 OH solution. Aliquots of 0.1 mI sample is loaded onto the cartridge, unbound peptide (sodium iodine-125) is eluted with 5 ml of 0.5mol/L sodium acetate solution, 125 I-Lanreotide is eluted with 5 mI of 95% aqueous ethanol solution. (C) The stability of 125 I-Lanreotide in vitro is investigated by labeling compound incubating for 48 hours at 37 deg. C in the 0.9% sodium chloride solution and RP is tested by PC at specific time intervals. (D) Lanreotide is labeled directly with 188 Re via the mixture of citrate and tartate using stannous chloride as reduced agent. The influence of reaction conditions such as pH, temperature, amount of stannous chloride, amount of Lanreotide and reaction time on labeling yield is investigated in detail. At the time, the stability in vitro quality control and animal test are evaluated

  17. The Use of Fibrous, Supramolecular Membranes and Human Tubular Cells for Renal Epithelial Tissue Engineering : Towards a Suitable Membrane for a Bioartificial Kidney

    NARCIS (Netherlands)

    Dankers, Patricia Y. W.; Boomker, Jasper M.; Huizinga-van der Vlag, Ali; Smedts, Frank M. M.; Harmsen, Martin C.; van Luyn, Marja J. A.

    2010-01-01

    A bioartificial kidney, which is composed of a membrane cartridge with renal epithelial cells, can substitute important kidney functions in patients with renal failure. A particular challenge is the maintenance of monolayer integrity and specialized renal epithelial cell functions ex vivo. We

  18. The use of fibrous, supramolecular membranes and human tubular cells for renal epithelial tissue engineering: towards a suitable membrane for a bioartificial kidney,

    NARCIS (Netherlands)

    Dankers, P.Y.W.; Boomker, J.M.; Huizinga-van der Vlag, A.; Smedts, F.M.M.; Harmsen, M.C.; Luyn, van M.J.A.

    2010-01-01

    A bioartificial kidney, which is composed of a membrane cartridge with renal epithelial cells, can substitute important kidney functions in patients with renal failure. A particular challenge is the maintenance of monolayer integrity and specialized renal epithelial cell functions ex vivo. We

  19. Direct anthelmintic effects of a purified chicory extract against free-living stages of Cooperia oncophora: preliminary results

    DEFF Research Database (Denmark)

    Pena-Espinoza, Miguel Angel; Williams, A.; Enemark, Heidi L.

    2013-01-01

    with methanol as the extraction medium. The resulting extract was dried and fractionated using solid-phase extraction (SPE) cartridges to enhance isolation of secondary metabolites such as sesquiterpene lactones. The obtained elutate was dried, dissolved in 100 % DMSO and serially diluted to obtain...

  20. Cholera Treatment

    Science.gov (United States)

    ... Diagnosis and Detection Laboratory Testing for Cholera Treatment Rehydration Therapy Antibiotic Treatment Zinc Treatment Prevention & Control Five ... page for current cholera treatment recommendations. Cholera Treatments Rehydration therapy , meaning prompt restoration of lost fluids and ...

  1. 49 CFR 173.230 - Fuel cell cartridges containing hazardous material.

    Science.gov (United States)

    2010-10-01

    ... integral vent feature) is deemed to pass the fire test if: (A) The internal pressure vents to zero gauge... required to power the equipment, plus two spares; (5) Large robust articles containing fuel cells may be...

  2. Comparison between sampling and analytical methods in characterization of pollutants in biogas.

    Science.gov (United States)

    Mariné, Sílvia; Pedrouzo, Marta; Marcé, Rosa Maria; Fonseca, Ignacio; Borrull, Francesc

    2012-10-15

    Different sampling methods involving the collection of biogas by Tedlar bags or adsorption tubes, and different GC-MS injection systems, loop injection or cold trap injection (with bags or by tube desorption), were compared to establish the best method to determine the minority compounds in biogas from sewage treatment plants (STPs). A study of parameters is included, such as the stability of compounds in Tedlar bags or cartridges and the adsorption effect of some less volatile compounds in the thermal desorption system (TD). The optimized methods allowed to determine most compounds at low mgm(-3) levels. Among them, maximum values of D5 (4.84 mg m(-3)), decane (95-118 mg m(-3)) and H(2)S (2223 mg m(-3)) were found in biogas samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Radioimmunoassay of deoxynivalenol in wheat and corn

    International Nuclear Information System (INIS)

    Xu, Y.C.; Zhang, G.S.; Chu, F.S.

    1986-01-01

    With the availability of antibody against deoxynivalenol triacetate (DON-triacetate), a radioimmunoassay (RIA) for DON in wheat was developed. DON is extracted from the sample with acetonitrile-water defatted with hexane, and then reacted with acetic anhydride to form DON-triacetate. The reaction mixture is loaded onto a C-18 cartridge to remove excess reagents and impurities. Acetylated DON is eluted from the cartridge with 50% methanol in water, and then analyzed by radioimmunoassay utilizing antiserum against DON-triacetate and tritiated DON-triacetate. Overall recovery for DON added to wheat between 50 and 5000 ppb was 86% with a standard deviation of 7% and coefficient of variation of 8%. The limit of detection for DON was about 20 ppb. Analysis of 12 naturally contaminated wheat, corn, and mixed feed samples for DON revealed that RIA results agreed well with thin layer chromatographic analyses performed by other laboratories

  4. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Use of a Non-Penetrating Captive Bolt for Euthanasia of Neonate Goats

    Directory of Open Access Journals (Sweden)

    Andrew Grist

    2018-04-01

    Full Text Available A non-penetrating captive bolt device, powered by a 1 grain 0.22″ cartridge delivering a calculated kinetic energy of 47 Joules was tested as a euthanasia method on 200 neonate goats (Capra aegagrus hircus of mean dead weight = 4.425 kg (SD (Standard deviation ± 0.4632, to assess effectiveness and shot position. Evaluation of the method was conducted using behavioural indicators of brain dysfunction followed by post mortem examination of the heads. Once correct shot position had been established, 100% of 158 kids (95% confidence interval 97.5% to 100% were successfully stunned/killed with a shot positioned on the midline, between the ears, with the chin tucked into the neck. The use of the Accles and Shelvoke CASH Small Animal Tool can therefore be recommended for the euthanasia of neonate goats with a 1 grain cartridge and a specific shooting position.

  6. Determination of emamectin benzoate in medicated fish feed.

    Science.gov (United States)

    Farer, L J; Hayes, J; Rosen, J; Knight, P

    1999-01-01

    A method was developed to quantitate emamectin benzoate in fish feed at levels between 5 and 15 ppm. The active ingredient is extracted from 20 g medicated feed into aqueous-methanolic solvent by overnight shaking. A solid-phase extraction procedure using a 2 g C18 cartridge is then used to concentrate the active residue and remove interfering matrix components. The extracted drug and internal standard are eluted from the cartridge, evaporated to dryness, and reconstituted in methanol. A control feed sample and fortified control working standard are simultaneously prepared. Remaining interferences and sample analysis are further separated on a gradient liquid chromatographic system. Recovery of emamectin benzoate from fortified feeds ranged from 97 to 100%, with a coefficient of variation (CV) of 1.2%. Determination of emamectin benzoate in medicated feeds resulted in CVs ranging from 2.3 to 4.2% and recoveries of 88 to 98% of label claim.

  7. A selective and simplified radioimmunoassay of 25-hydroxyvitamin D3

    International Nuclear Information System (INIS)

    Hummer, L.; Nilas, L.; Tjellesen, L.; Christiansen, C.

    1984-01-01

    A simple, non-chromatographic and selective assay for determination of 250 HD 3 in serum is described. The serum sample is deproteinated with acetonitrile and the supernatant purified over a small prepacked cartridge, Sep-pak. In the eluate from the cartridge, 250 HD 3 is measured by radioimmunoassay. The selectivity of the assay for 250 HD 3 is improved by adding vitamin D 2 to the antiserum; the assay is thus capable of measuring 250 HD 3 in serum samples containing up to a ratio of 250 HD 2 /250 HD 3 equal to 150. The simplicity, speed and the small amount of sample needed (0.5 ml) make this method suitable for use in a routine clinical laboratory. Because of its selectivity for 250 HD 3 the assay is a necessary prerequisite in the further investigation of metabolic discrimination between vitamins D 2 and D 3 . (author)

  8. Analysis Study of Stevioside and Rebaudioside A from Stevia rebaudiana Bertoni by Normal Phase SPE and RP-HPLC

    Science.gov (United States)

    Martono, Y.; Rohman, A.; Riyanto, S.; Martono, S.

    2018-04-01

    Solid Phase Extraction (SPE) method using silica as sorbent for stevioside and rebaudiosida A analysis in Stevia rebaudiana Bertoni leaf have not been performed. The aim of this study is to develop SPE method using silica as sorbent for Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) analysis of stevioside and rebaudiosida A in S. rebaudiana leaf. The results of this study indicate that the optimal conditions for normal phase SPE (silica) are conditioned with 3.0 mL of hexane. The sample loading volume is 0.1 mL. Cartridge is eluted with 1.0 mL acetonitrile: water (80: 20, v/v) to separate both analytes. The cartridge is washed with chloroform and water of 0.3 mL respectively. The developed SPE sample preparation method meets the accuracy and precision test and can be used for the analysis of stevioside and rebaudioside A by RP-HPLC.

  9. National and State-Specific Sales and Prices for Electronic Cigarettes—U.S., 2012–2013

    Science.gov (United States)

    Loomis, Brett R.; Rogers, Todd; King, Brian A.; Dench, Daniel L.; Gammon, Doris G.; Fulmer, Erika B.; Agaku, Israel T.

    2015-01-01

    Introduction The growing market for electronic cigarettes (e-cigarettes) has been widely reported in the media, but very little objective data exist in the scientific literature, and no data have been published on state-specific trends in prices or sales. Our objective is to assess state-specific annual sales and average prices for e-cigarettes in the U.S. Methods Commercial retail scanner data were used to assess total dollar sales and average price per unit for disposable e-cigarettes, starter kits, and cartridge refills for selected states and the total U.S. during 2012–2013. Data were analyzed in 2014. Data were available for convenience stores (29 states) and food, drug, and mass merchandisers (44 states). Results In convenience stores, dollar sales increased markedly during 2012–2013: 320.8% for disposable e-cigarettes, 72.4% for starter kits, and 82% for cartridges. In food, drug, and mass merchandisers, dollar sales increased 49.5% for disposable e-cigarettes, 89.4% for starter kits, and 126.2% for cartridges. Average prices across all product categories increased in convenience stores and decreased in food, drug, and mass merchandisers. Sales and prices varied substantially across states included in the analyses. Conclusions Sales of all e-cigarette device types grew considerably in convenience stores and food, drug, and mass merchandisers during 2012–2013. The market for e-cigarettes is growing rapidly, resulting in dynamic sales and price changes that vary across the U.S. Continued state-specific surveillance of the e-cigarette market is warranted. PMID:26163173

  10. The effect of sucralose on flavor sweetness in electronic cigarettes varies between delivery devices.

    Directory of Open Access Journals (Sweden)

    Kathryn Rosbrook

    Full Text Available The appeal of sweet electronic cigarette flavors makes it important to identify the chemical compounds that contribute to their sweetness. While volatile chemicals that produce sweet aromas have been identified in e-liquids, there are no published reports of sugars or artificial sweeteners in commercial e-liquids. However, the sweetener sucralose is marketed as an e-liquid additive to commercial flavors. The primary aims of the study were to determine if sucralose is delivered in sufficient concentration in the inhaled aerosol to enhance flavor sweetness, and whether the amount delivered depends on the e-liquid delivery system. Thirty-two adult smokers rated flavor intensity, sweetness, harshness and liking/disliking for 4 commercial flavors with and without sucralose (1% using 2 e-cigarette delivery systems (cartridge and tank. Participants alternately vaped normally or with the nose pinched closed to block perception of volatile flavor components via olfaction. LC/MS was used to measure the concentration of sucralose in the e-liquid aerosols using a device that mimicked vaping. Sweetness and flavor intensity were perceived much more strongly when olfaction was permitted. The contribution of sucralose to sweetness was significant only for the cartridge system, and the chemical analysis showed that the concentration of sucralose in the aerosol was higher when the cartridge was used. Together these findings indicate that future regulation of sweet flavor additives should focus first on the volatile constituents of e-liquids with the recognition that artificial sweeteners may also contribute to flavor sweetness depending upon e-cigarette design.

  11. National and State-Specific Sales and Prices for Electronic Cigarettes-U.S., 2012-2013.

    Science.gov (United States)

    Loomis, Brett R; Rogers, Todd; King, Brian A; Dench, Daniel L; Gammon, Doris G; Fulmer, Erika B; Agaku, Israel T

    2016-01-01

    The growing market for electronic cigarettes (e-cigarettes) has been widely reported in the media, but very little objective data exist in the scientific literature, and no data have been published on state-specific trends in prices or sales. Our objective is to assess state-specific annual sales and average prices for e-cigarettes in the U.S. Commercial retail scanner data were used to assess total dollar sales and average price per unit for disposable e-cigarettes, starter kits, and cartridge refills for selected states and the total U.S. during 2012-2013. Data were analyzed in 2014. Data were available for convenience stores (29 states) and food, drug, and mass merchandisers (44 states). In convenience stores, dollar sales increased markedly during 2012-2013: 320.8% for disposable e-cigarettes, 72.4% for starter kits, and 82% for cartridges. In food, drug, and mass merchandisers, dollar sales increased 49.5% for disposable e-cigarettes, 89.4% for starter kits, and 126.2% for cartridges. Average prices across all product categories increased in convenience stores and decreased in food, drug, and mass merchandisers. Sales and prices varied substantially across states included in the analyses. Sales of all e-cigarette device types grew considerably in convenience stores and food, drug, and mass merchandisers during 2012-2013. The market for e-cigarettes is growing rapidly, resulting in dynamic sales and price changes that vary across the U.S. Continued state-specific surveillance of the e-cigarette market is warranted. Copyright © 2016 American Journal of Preventive Medicine. All rights reserved.

  12. Lab-on-a-Chip: From Astrobiology to the International Space Station

    Science.gov (United States)

    Maule, Jake; Wainwright, Nor; Steele, Andrew; Gunter, Dan; Monaco, Lisa A.; Wells, Mark E.; Morris, Heather C.; Boudreaux, Mark E.

    2008-01-01

    The continual and long-term habitation of enclosed environments, such as Antarctic stations, nuclear submarines and space stations, raises unique engineering, medical and operational challenges. There is no easy way out and no easy way to get supplies in. This situation elevates the importance of monitoring technology that can rapidly detect events within the habitat that affect crew safety such as fire, release of toxic chemicals and hazardous microorganisms. Traditional methods to monitor microorganisms on the International Space Station (ISS) have consisted of culturing samples for 3-5 days and eventual sample return to Earth. To augment these culture methods with new, rapid molecular techniques, we developed the Lab-on-a-Chip Application Development - Portable Test System (LOCAD-PTS). The system consists of a hand-held spectrophotometer, a series of interchangeable cartridges and a surface sampling/dilution kit that enables crew to collect samples and detect a range of biological molecules, all within 15 minutes. LOCAD-PTS was launched to the ISS aboard Space Shuttle Discovery in December 2006, where it was operated for the first time during March-May 2007. The surfaces of five separate sites in the US Lab and Node 1 of ISS were analyzed for endotoxin, using cartridges that employ the Limulus Amebocyte Lysate (LAL) assay; results of these tests will be presented. LOCAD-PTS will remain permanently onboard ISS with new cartridges scheduled for launch in February and October of 2008 for the detection of fungi (Beta-glucan) and Gram-positive bacteria (lipoteichoic acid), respectively.

  13. Treatment goals and treatment in exercise therapy.

    NARCIS (Netherlands)

    Zuijderduin, W.M.; Dekker, J.

    1994-01-01

    In the present study a quantitative description is given of treatment in exercise therapy according to Cesar and according to Mensendieck. Information was gathered from saurvey on exercise therapy in the Netherlands. Characteristics of treatment are described including treatment goals, emphasis of

  14. Treatment diary for botulinum toxin spasticity treatment

    DEFF Research Database (Denmark)

    Biering-Sørensen, Bo; Iversen, Helle K; Frederiksen, Inge M S

    2017-01-01

    The aim of this study is to develop a treatment diary for patients receiving spasticity treatment including botulinum toxin injection and physiotherapy and/or occupational therapy. The diary focuses on problems triggered by skeletal muscle overactivity; agreed goals for treatment and the patient...

  15. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    Science.gov (United States)

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  16. 42 CFR 84.197 - Respirator containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Respirator containers; minimum requirements. 84.197... Cartridge Respirators § 84.197 Respirator containers; minimum requirements. Respirators shall be equipped with a substantial, durable container bearing markings which show the applicant's name, the type and...

  17. 76 FR 82163 - Hazardous Materials: Harmonization With the United Nations Recommendations on the Transport of...

    Science.gov (United States)

    2011-12-30

    ... cartridges to be transported as ORM-D-AIR by aircraft so that fuel cell technologies are not placed at a disadvantage compared to other technologies authorized to be transported by aircraft. PHMSA response. We deny... Association (FCHEA) Healthcare Distribution Management Association (HDMA) International Air Transport...

  18. Analysis of large soil samples for actinides

    Science.gov (United States)

    Maxwell, III; Sherrod, L [Aiken, SC

    2009-03-24

    A method of analyzing relatively large soil samples for actinides by employing a separation process that includes cerium fluoride precipitation for removing the soil matrix and precipitates plutonium, americium, and curium with cerium and hydrofluoric acid followed by separating these actinides using chromatography cartridges.

  19. 42 CFR 84.198 - Half-mask facepieces, full facepieces, mouthpieces, hoods, and helmets; fit; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Half-mask facepieces, full facepieces, mouthpieces... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Chemical Cartridge Respirators § 84.198 Half-mask facepieces, full facepieces, mouthpieces, hoods, and helmets; fit; minimum requirements. (a) Half-mask facepieces...

  20. Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities

    DEFF Research Database (Denmark)

    Bade, Richard; Bijlsma, Lubertus; Sancho, Juan V.

    2017-01-01

    (SPE) with Oasis MCX cartridges. Isotopically labelled internal standards were used to correct for matrix effects and potential SPE losses. Following chromatographic separation on a C18 column within 6 min, the compounds were measured by tandem mass spectrometry in positive ionization mode. The method...

  1. 40 CFR 133.105 - Treatment equivalent to secondary treatment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Treatment equivalent to secondary treatment. 133.105 Section 133.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.105 Treatment equivalent to secondary treatment...

  2. Treatment-refractory anxiety; definition, risk factors, and treatment challenges.

    Science.gov (United States)

    Roy-Byrne, Peter

    2015-06-01

    A sizable proportion of psychiatric patients will seek clinical evaluation and treatment for anxiety symptoms reportedly refractory to treatment. This apparent lack of response is either due to "pseudo-resistance" (a failure to have received and adhered to a recognized and effective treatment or treatments for their condition) or to true "treatment resistance." Pseudo-resistance can be due to clinician errors in selecting and delivering an appropriate treatment effectively, or to patient nonadherence to a course of treatment. True treatment resistance can be due to unrecognized exogenous anxiogenic factors (eg, caffeine overuse, sleep deprivation, use of alcohol or marijuana) or an incorrect diagnosis (eg, atypical bipolar illness, occult substance abuse, attention deficit-hyperactivity disorder). Once the above factors are eliminated, treatment should focus on combining effective medications and cognitive behavioral therapy, combining several medications (augmentation), or employing novel medications or psychotherapies not typically indicated as first-line evidence-based anxiety treatments.

  3. Treatment-refractory anxiety; definition, risk factors, and treatment challenges

    Science.gov (United States)

    Roy-Byrne, Peter

    2015-01-01

    A sizable proportion of psychiatric patients will seek clinical evaluation and treatment for anxiety symptoms reportedly refractory to treatment. This apparent lack of response is either due to “pseudo-resistance” (a failure to have received and adhered to a recognized and effective treatment or treatments for their condition) or to true “treatment resistance.” Pseudo-resistance can be due to clinician errors in selecting and delivering an appropriate treatment effectively, or to patient nonadherence to a course of treatment. True treatment resistance can be due to unrecognized exogenous anxiogenic factors (eg, caffeine overuse, sleep deprivation, use of alcohol or marijuana) or an incorrect diagnosis (eg, atypical bipolar illness, occult substance abuse, attention deficit-hyperactivity disorder). Once the above factors are eliminated, treatment should focus on combining effective medications and cognitive behavioral therapy, combining several medications (augmentation), or employing novel medications or psychotherapies not typically indicated as first-line evidence-based anxiety treatments. PMID:26246793

  4. Development a recovery method of 13I from the 23'5U fission products

    International Nuclear Information System (INIS)

    Bignardi, Aline M.T.; Osso Junior, Joao Alberto

    2013-01-01

    13I is a iodine radioisotope widely used in nuclear medicine that can be used either for diagnostic or for treatment due to its physical decay by β- and its high emission of rays-γ. It is produced at IPEN through the irradiation of TeO 2 targets in the IEA-R1 nuclear reactor. There is also the possibility produced it by the fission of 235 U. The aim of this work is to develop a recovery method of 13I in the production process of 99 Mo through the route of acid dissolution of 235 U targets, with the quality to be used in Nuclear Medicine. 13I finds itself in two stages of the process, either in the gaseous produced in the acid dissolution of metallic U targets and the smallest part in solution. In this work was studied the recovery of 131 in these two stages. Several materials were used for the capture and recovery of 13I at the two phases of the process. Anionic cartridges, Ag cartridges, anion exchange resin, activated charcoal columns and AgI precipitation were tested. Solutions with 13 '1I in 0.1 mol.L -1 NaOH were percolated through the materials and the eluted solutions were analyzed in a dose calibrator. Among all the tests that were executed, at first, the anion exchange resin and AgI precipitation have showed the best retention result (100%). The results of elution have varied according to the material, the activated charcoal presented a elution yield between 70% and 82% At first, it is possible to conclude that anion exchange resin and AgI precipitation show better results for 13I retention and the column and activated charcoal have a great potential for the elution of 131 in the right chemical state. (author)

  5. New practical algorithm for modelling analyte recovery in bioanalytical reversed phase and mixed-mode solid phase extraction

    NARCIS (Netherlands)

    Hendriks, G.; Uges, D. R. A.; Franke, J. P.

    2008-01-01

    Solid phase extraction (SPE) is a widely used method for sample cleanup and sample concentration in bioanalytical sample preparation. A few methods to model the retention behaviour on SPE cartridges have been described previously but they are either not applicable to ionised species or are not

  6. 75 FR 78976 - Procurement List Proposed Addition and Deletions

    Science.gov (United States)

    2010-12-17

    ... NSN: 7510-01-555-6167--Inkjet printer cartridge NPA: Alabama Industries for the Blind, Talladega, AL.../Location: Eyewear Prescription Service, Phoenix Indian Medical Center, 4212 N. 16th Street, Phoenix, AZ. NPA: Winston-Salem Industries for the Blind, Winston-Salem, NC. Contracting Activity: Health and Human...

  7. Evaluative Testing of Sheep Ranching Site 5LA2316, 5LA2366, and 5LA2359 on the Pinon Canyon Maneuver Site, Las Animas County, Colorado

    Science.gov (United States)

    2009-06-01

    photographed, mapped, and bagged separately for water screening and/or flotation . Units were considered culturally sterile when the last 20 centimeters...shanks (TPQ 1830), one metal fragment, one small piece of aqua glass and a .42 caliber copper rim-fire cartridge casing manufactured by the Union Metallic

  8. Beating Back Bacteria

    Science.gov (United States)

    1998-01-01

    Under a NASA-Johnson Space Center contract, Umpqua Research developed the MCV (Trademark) (Microbial Check Valve) which uses iodinated ion exchange resin used for water purification systems aboard space missions. Using this resin, MRLB International, Inc., developed and commercialized the Dentapure purification cartridge used by dentists nationwide.

  9. A Sideband-Separating Mixer Upgrade for ALMA Band 9

    NARCIS (Netherlands)

    Hesper, R.; Gerlofsma, G.; Mena, P.; Spaans, M.; Baryshev, A.

    2009-01-01

    The ALMA band 9 (600-720 GHz) receiver cartridge, as currently being produced, features two single-ended (dual sideband) SIS mixers in orthogonal polarisations. In the case of spectral line observations in the presence of atmospheric backgound, the integration time to reach a certain desired signal

  10. A liquid chromatography-tandem mass spectrometry method for simultaneous analysis of acrylamide and the precursors, asparagine and reducing sugars in bread

    DEFF Research Database (Denmark)

    Nielsen, N.J.; Granby, Kit; Hedegaard, Rikke Susanne Vingborg

    2006-01-01

    A LC-MS-MS method for simultaneous determination of acrylamide, asparagine, fructose, glucose and sucrose in bread was developed. The method is based on aqueous extraction by blending. After centrifugation the samples were cleaned up by solid phase extraction on C18 cartridges conditioned with 2 ...

  11. SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine.

    Science.gov (United States)

    Kubota, Ryuichi; Endo, Yoko; Takeuchi, Akito; Inoue, Yoshinori; Ogata, Hiroko; Ogawa, Masanori; Nakagawa, Tomoo; Onda, Nobuhiko; Endo, Ginji

    2007-07-01

    An analytical method using a combination of solid-phase extraction (SPE) and gas chromatography with a flame thermionic detector (GC/FTD) was developed for determination of N-methyl-2-pyrrolidone (NMP), N-methylsuccinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) in human urine. The SPE cartridge of poly(divinylbenzene/hydroxymethacrylate) used was directly loaded with urine sample, followed by elution with methyl isobutyl ketone (MIBK) and subsequent centrifugation, and the supernatant was injected into the capillary GC using a DB1701. This method allowed efficient separation of NMP, MSI, and 2-HMSI, which were nearly free of interference by other GC peaks arising from urine. Recoveries of NMP, MSI, and 2-HMSI from the SPE cartridge were about 98, 101, and 67%, respectively, with limits of detection of 0.04, 0.02, and 0.06 mg/L, respectively, which met the regulatory requirements. The present method was used for assay in biological monitoring of workers exposed to NMP in their occupational environment.

  12. Comparing systolic and diastolic Blood pressure changes and heartbeat rate following administration of anesthetics containing epinephrine and felypressin

    Directory of Open Access Journals (Sweden)

    M. Jafari

    1998-05-01

    Full Text Available   Complex mechanisms have been known for keeping blood pressure in normal level. In fact, these mechanisms have inter-related functions and can be dysregulated by both internal and external stimuli while cardiovascular system functions to minimize these changes. Vasoconstrictors can cause clinical and hemodynamical changes as 1-2 cartridges of epinephrine containing lidocaine can has no considerable effects in a normal individual ( unless administered IV but 3 cartridges can bring about some clinical symptoms, according to a number of investigations. In current study, epinephrine’s effect on heartbeat rate was found more potent than felypressin which is considered as a disadvantage. on the other hand, epinephrine acts on arteries and can cause less bleeding, less drug toxicity and deeper and longer anesthesia. Therefore, it is preferred to felypressin due to its better action. It should be noted that the changes resulted by epinephrine and felypressin are of no significant importance in healthy individuals.

  13. Simultaneous determination of kasugamycin and validamycin-A residues in cereals by consecutive solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Hong; Wang, Chenchen; Li, Huidong; Nie, Yan; Fang, Liping; Chen, Zilei

    2018-03-01

    Two polar aminoglycosides, kasugamycin and validamycin-A, were determined in cereals (brown rice, wheat and corn) by high-performance liquid chromatography-tandem mass spectrometry. The analytes were extracted from samples using methanol and water (70:30, v/v) at pH 5.5, purified using both a hydrophilic-hydrophobic-balanced cartridge and a strong cation-exchange cartridge, and then analysed using multiple reaction monitoring in positive electrospray ionisation mode with a special ReproSil 100 C 18 high-performance liquid chromatography column. This newly proposed method yielded good sensitivity and excellent chromatographic performance. The limits of quantification for kasugamycin and validamycin-A were 4.1 µg/kg and 1.0 µg/kg, respectively. The recoveries for both compounds at three fortification levels (4, 100 and 500 µg/kg for kasugamycin; 1, 10 and 100 µg/kg for validamycin-A) ranged from 75% to 110%, and the relative standard deviations were below 15%.

  14. Development of procedures for calculating stiffness and damping properties of elastomers. Part 3: The effects of temperature, dissipation level and geometry

    Science.gov (United States)

    Smalley, A. J.; Tessarzik, J. M.

    1975-01-01

    Effects of temperature, dissipation level and geometry on the dynamic behavior of elastomer elements were investigated. Force displacement relationships in elastomer elements and the effects of frequency, geometry and temperature upon these relationships are reviewed. Based on this review, methods of reducing stiffness and damping data for shear and compression test elements to material properties (storage and loss moduli) and empirical geometric factors are developed and tested using previously generated experimental data. A prediction method which accounts for large amplitudes of deformation is developed on the assumption that their effect is to increase temperature through the elastomers, thereby modifying the local material properties. Various simple methods of predicting the radial stiffness of ring cartridge elements are developed and compared. Material properties were determined from the shear specimen tests as a function of frequency and temperature. Using these material properties, numerical predictions of stiffness and damping for cartridge and compression specimens were made and compared with corresponding measurements at different temperatures, with encouraging results.

  15. 3D Printing and Assay Development for Point-of-Care Applications

    Science.gov (United States)

    Jagadeesh, Shreesha

    Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.

  16. A web-based platform for virtual screening.

    Science.gov (United States)

    Watson, Paul; Verdonk, Marcel; Hartshorn, Michael J

    2003-09-01

    A fully integrated, web-based, virtual screening platform has been developed to allow rapid virtual screening of large numbers of compounds. ORACLE is used to store information at all stages of the process. The system includes a large database of historical compounds from high throughput screenings (HTS) chemical suppliers, ATLAS, containing over 3.1 million unique compounds with their associated physiochemical properties (ClogP, MW, etc.). The database can be screened using a web-based interface to produce compound subsets for virtual screening or virtual library (VL) enumeration. In order to carry out the latter task within ORACLE a reaction data cartridge has been developed. Virtual libraries can be enumerated rapidly using the web-based interface to the cartridge. The compound subsets can be seamlessly submitted for virtual screening experiments, and the results can be viewed via another web-based interface allowing ad hoc querying of the virtual screening data stored in ORACLE.

  17. Liquid chromatographic-diode-array detection multiresidue determination of rice herbicides in drinking and paddy-field water.

    Science.gov (United States)

    Roehrs, Rafael; Zanella, Renato; Pizzuti, Ionara; Adaime, Martha B; Pareja, Lucía; Niell, Silvina; Cesio, María V; Heinzen, Horacio

    2009-01-01

    A sensitive, rapid, and simple multiresidue method for the simultaneous determination of six postemergence herbicides currently used in rice cultivation--metsulfuron methyl, bensulfuron methyl, pyrazosulfuron ethyl, bentazone, bispyribac sodium, and cyhalofop butyl--in drinking and paddy-field water is presented. Water samples were extracted with solid-phase extraction cartridges. Final determination was made by LC with diode-array detection. The extraction efficiencies of C18 and HLB cartridges were compared. The average recovery obtained for these compounds for the lowest spiked level (0.1 microg/L) varied from 70 to 122% for C18 and 75-119% for HLB, with RSDs of 11 and 8.3%, respectively. The method had good linearity, and the lower detection limit for the pesticides studied varied from 0.03 to 0.04 microg/L. The proposed method was also tested in paddy-field water, with recovery studies giving good results with low RSDs at 1.0 microg/L.

  18. Two-step method for creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy.

    Science.gov (United States)

    Liu, Yu; Li, Ji-Jia; Zu, Peng; Liu, Hong-Xu; Yu, Zhan-Wu; Ren, Yi

    2017-12-07

    To introduce a two-step method for creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy and assess its clinical application. One hundred and twenty-two patients with middle or lower esophageal cancer who underwent laparoscopic-thoracoscopic Ivor-Lewis esophagectomy at Liaoning Cancer Hospital and Institute from March 2014 to March 2016 were included in this study, and divided into two groups based on the procedure used for creating a gastric tube. One group used a two-step method for creating a gastric tube, and the other group used the conventional method. The two groups were compared regarding the operating time, surgical complications, and number of stapler cartridges used. The mean operating time was significantly shorter in the two-step method group than in the conventional method group [238 (179-293) min vs 272 (189-347) min, P creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy has the advantages of simple operation, minimal damage to the tubular stomach, and reduced use of stapler cartridges.

  19. Volatile organic compound measurements in the California/Mexico border region during SCOS97

    International Nuclear Information System (INIS)

    Zielinska, B.; Sagebiel, J.; Harshfield, G.; Pasek, R.

    2001-01-01

    Measurements of volatile organic compounds (VOC) were carried out in the California/Mexico border region during the Southern California Ozone Study in the summer of 1997 (SCOS97). Integrated 3-h samples were collected in Rosarito (south of Tijuana, Mexico) and in Mexicali during intensive operational periods (IOP), twice per IOP day. VOC were collected using stainless-steel 6-l canisters; carbonyl compounds were collected using 2,4-dinitrophenylhydrazine (DNPH) impregnated C18 SepPak cartridges. The canister samples were analyzed for speciated volatile hydrocarbons (C 2 -C 12 ), CO, CO 2 , CH 4 , methyl t-butyl ether (MTBE), and halogenated hydrocarbons. DNPH-impregnated cartridges were analyzed for 14 C 1 -C 7 carbonyl compounds. The concentrations of all species were higher at Mexicali than in Rosarito. A good correlation between total non-methane hydrocarbons (TNMHC), CO, and other pollutants associated with motor vehicle emissions observed for Mexicali indicates that the main source of TNMHC at this site is vehicular traffic

  20. Team training using full-scale reactor coolant pump seal mock-ups

    International Nuclear Information System (INIS)

    McDonald, T.J.; Hamill, R.W.

    1987-01-01

    The use of full-scale reactor coolant pump (RCP) seal mock-ups has greatly enhanced Northeast Utilities' ability to effectively utilize the team training approach to technical training. With the advent of the Institute of Nuclear Power Operations accreditation come a new emphasis and standards for the integrated training of plant engineering personnel, maintenance mechanics, quality control personnel, and health physics personnel. The results of purchasing full-scale RCP mock-ups to pilot the concept of team training have far exceeded expectations and cost-limiting factors. The initial training program analysis identified RCP seal maintenance as a task that required training for maintenance department personnel. Due to radiation exposure considerations and the unavailability of actual plant equipment for training purposes, the decision was made to procure a mock-up of an RCP seal assembly and housing. This mock-up was designed to facilitate seal cartridge removal, disassembly, assembly, and installation, duplicating all internal components of the seal cartridge and housing area in exact detail

  1. Catalytic pleat filter bags for combined particulate separation and nitrogen oxides removal from flue gas streams

    International Nuclear Information System (INIS)

    Park, Young Ok; Choi, Ho Kyung

    2010-01-01

    The development of a high temperature catalytically active pleated filter bag with hybrid filter equipment for the combined removal of particles and nitrogen oxides from flue gas streams is presented. A special catalyst load in stainless steel mesh cartridge with a high temperature pleated filter bag followed by optimized catalytic activation was developed to reach the required nitrogen oxides levels and to maintain the higher collection efficiencies. The catalytic properties of the developed high temperature filter bags with hybrid filter equipment were studied and demonstrated in a pilot scale test rig and a demonstration plant using commercial scale of high temperature catalytic pleated filter bags. The performance of the catalytic pleated filter bags were tested under different operating conditions, such as filtration velocity and operating temperature. Moreover, the cleaning efficiency and residual pressure drop of the catalyst loaded cartridges in pleated filter bags were tested. As result of theses studies, the optimum operating conditions for the catalytic pleated filter bags are determined. (author)

  2. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    Science.gov (United States)

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2016-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtain required parts; 2) assembly of the dialyzer; and 3) sealing the dialyzer with epoxy. Preparation of the dialyser takes about 1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1–24 h, depending on the analyte and membrane employed. We previously used the dialyzer for small-volume nonenzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading, and vesicle microscopy. PMID:26020615

  3. Construction of a liposome dialyzer for the preparation of high-value, small-volume liposome formulations.

    Science.gov (United States)

    Adamala, Katarzyna; Engelhart, Aaron E; Kamat, Neha P; Jin, Lin; Szostak, Jack W

    2015-06-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for the rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges (Slide-A-Lyzer cassettes), and it consists of a reactor with two 300-μl chambers and a 1.56-cm(2) dialysis surface area. The dialyzer is prepared in three stages: (i) disassembling the dialysis cartridges to obtain the required parts, (ii) assembling the dialyzer and (iii) sealing the dialyzer with epoxy. Preparation of the dialyzer takes ∼1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1-24 h, depending on the analyte and membrane used. We previously used the dialyzer for small-volume non-enzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading and vesicle microscopy.

  4. Determination of 99Tc in fresh water using TRU resin by ICP-MS.

    Science.gov (United States)

    Guérin, Nicolas; Riopel, Remi; Kramer-Tremblay, Sheila; de Silva, Nimal; Cornett, Jack; Dai, Xiongxin

    2017-10-02

    Technetium-99 ( 99 Tc) determination at trace level by inductively coupled plasma mass spectrometry (ICP-MS) is challenging because there is no readily available appropriate Tc isotopic tracer. A new method using Re as a recovery tracer to determine 99 Tc in fresh water samples, which does not require any evaporation step, was developed. Tc(VII) and Re(VII) were pre-concentrated on a small anion exchange resin (AER) cartridge from one litre of water sample. They were then efficiently eluted from the AER using a potassium permanganate (KMnO 4 ) solution. After the reduction of KMnO 4 in 2 M sulfuric acid solution, the sample was passed through a small TRU resin cartridge. Tc(VII) and Re(VII) retained on the TRU resin were eluted using near boiling water, which can be directly used for the ICP-MS measurement. The results for method optimisation, validation and application were reported. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  5. A novel option for reducing free light chains in myeloma kidney: supra-hemodiafiltration with endogenous reinfusion (HFR).

    Science.gov (United States)

    Pasquali, Sonia; Iannuzzella, Francesco; Corradini, Mattia; Mattei, Silvia; Bovino, Achiropita; Stefani, Alfredo; Palladino, Giuseppe; Caiazzo, Marialuisa

    2015-04-01

    In myeloma cast nephropathy, fast reduction of serum free light chain (FLC) levels correlates with renal recovery. Recently, extracorporeal treatments using filters with a high-molecular weight cut-off have been successfully used for FLC removal. However, using these new filters, high cost and elevated albumin leakage are common drawbacks. We studied a new and cheaper therapeutic approach with adsorbent resins to evaluate its efficacy. We treated four patients, affected by dialysis-dependent acute kidney injury (AKI) due to biopsy proven de novo FLC myeloma cast nephropathy. Each patient underwent bortezomib chemotherapy and extracorporeal treatment with the supra-hemodiafiltration with endogenous reinfusion (HFR) technique (Supra-HFR, Bellco Mirandola, Modena, Italy). Supra-HFR is a kind of hemodiafiltration that utilizes separated convection, diffusion and adsorption. The sorbent cartridge has a high affinity for FLC (both κ and λ) but is able to re-infuse albumin, avoiding the need for albumin perfusions. Supra HFR treatments (4 h each) were carried out for eight consecutive days and then every other day. All patients showed a significant reduction of serum FLC, whereas serum albumin concentration remained unchanged. Renal function recovered in three out of four patients. FLC removal with adsorbent resins represents an effective therapeutic strategy that does not require replacement with albumin .

  6. Quality Improvement of a Small Water Supply. A Practical Application of a Full System of Nanofiltration

    Directory of Open Access Journals (Sweden)

    R. Marin Galvin

    2013-04-01

    Full Text Available The THM level in the Spanish drinking water is limited to less than 0.100 mg/L, due to its potential toxicological effect on humans. This paper investigates the comparison of the results obtained in a small supply of water that historically presented THM contents out of the Spanish normative, versus the results there obtained when the treatment was modified with the inclusion of a nanofiltration system. So, the conventional treatment first applied was that of pre-oxidation with chlorine and/or KMnO4, followed by coagulation with aluminum salts directly on closed sand filter, and disinfection final by chlorination: with this system, THM levels lower than 0.100 mg/L were not always secured. Thus, to improve the water quality, a full system of nanofiltration was implemented, after the above treatment, consisting in: pre-filtration through cartridges, filtration over activated carbon, post-filtration for retaining impurities, and finally, nanofiltration and chlorination of water after nanofiltration. In this order, the new treatment scheme has usually produced water with maximum THM levels of 0.058 mg/L, and average values of 0.013 mg/L, 0.30 mg/L for organic matter concentrations, and water always microbiologically pure. Also, the contents of Fe, Mn and Al in the treated water were significantly reduced with respect to the previous situation without nanofiltration.

  7. Incontinence Treatment: Biofeedback

    Science.gov (United States)

    ... Treatment Lifestyle Changes Dietary Tips Medication Bowel Management Biofeedback Surgical Treatments Newer Treatment Options Tips on Finding ... Treatment Lifestyle Changes Dietary Tips Medication Bowel Management Biofeedback Surgical Treatments Newer Treatment Options Tips on Finding ...

  8. Treatment Effects

    DEFF Research Database (Denmark)

    Heckman, James J.; Lopes, Hedibert F.; Piatek, Rémi

    2014-01-01

    This paper contributes to the emerging Bayesian literature on treatment effects. It derives treatment parameters in the framework of a potential outcomes model with a treatment choice equation, where the correlation between the unobservable components of the model is driven by a low-dimensional v......This paper contributes to the emerging Bayesian literature on treatment effects. It derives treatment parameters in the framework of a potential outcomes model with a treatment choice equation, where the correlation between the unobservable components of the model is driven by a low...... to observe the same person in both the treated and untreated states, but it also turns out to be straightforward to implement. Formulae are provided to compute mean treatment effects as well as their distributional versions. A Monte Carlo simulation study is carried out to illustrate how the methodology can...

  9. Efficacy of Jatropha, Annona and Parthenium biowash on ...

    African Journals Online (AJOL)

    ... rot in chickpea) and Macrophomina phaseolina (causes charcoal rot in sorghum). ... crude biowash was also passed through C18 solid phase extraction cartridges and ... When the organic fraction of Jatropha biowash was further fractionated by ... Hence, it was concluded that one of these three bands could be the active

  10. Inhibition of Tulane Virus replication via exposure to lowbush blueberry (Vaccinium angustifolium) fractional components

    Science.gov (United States)

    Tulane Virus (TV) is a common viral surrogate for human norovirus in lab studies. In the present study, the phenotypic response of TV when exposed to fractional components extracted from lowbush blueberries was investigated. Lowbush blueberry extract (F1) was separated using a C-18 Sep-Pak cartridge...

  11. 37 CFR 1.824 - Form and format for nucleotide and/or amino acid sequence submissions in computer readable form.

    Science.gov (United States)

    2010-07-01

    ... System Compatibility: MS-DOS, MS-Windows, Unix or Macintosh; (3) Line Terminator: ASCII Carriage Return... command; specify blocking factor (not “block size”); Line Terminator: ASCII Carriage Return plus ASCII Line Feed. (3) 8mm Data Cartridge: Format: Unix tar command; specify blocking factor (not “block size...

  12. 30 CFR 56.6304 - Primer protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Primer protection. 56.6304 Section 56.6304 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Primer protection. (a) Tamping shall not be done directly on a primer. (b) Rigid cartridges of explosives...

  13. 76 FR 78616 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-12-19

    ... Devices/Propellant Actuated Devices (CAD/PAD), repair and return, modification kits, spares and repair... services, Cartridge Actuated Devices/ Propellant Actuated Devices (CAD/PAD), repair and return... information. 3. The AN/APG-68(V)9 radar is the latest model of the APG-68 radar and was specifically designed...

  14. Sideband Separating Mixer for 600-720 GHz

    NARCIS (Netherlands)

    Khudchenko, Andrey; Hesper, Ronald; Barychev, Andrey; Gerlofma, Gerrit; Mena, Patricio; Zijlstra, Tony; Klapwijk, Teun; Spaans, Marco; Kooi, Jacob W.; Zhang, C; Zhang, XC; Siegel, PH; He, L; Shi, SC

    2010-01-01

    The ALMA Band 9 receiver cartridge (600-720 GHz) based on Dual Sideband (DSB) superconductor-insulator-superconductor (SIS) mixer is currently in full production. In the case of spectral line observations, the integration time to reach a certain signal-to-noise level can be reduced by about a factor

  15. Evaluation of a nonevaporable getter pump for tritium handling in the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Singleton, M.F.; Griffith, C.M.

    1978-01-01

    Lawrence Livermore Laboratory has tested and evaluated a commercially available getter pump for use with tritium in the Tokamak Fusion Test Reactor (TFTR). The pump contains Zr(84%)--Al in cartridge form with a concentric heating unit. It performed well in all tests, except for frequent heater failures

  16. Low Temperature Particle Filtration of Wood Gas with Low Tar Content

    DEFF Research Database (Denmark)

    Hindsgaul, Claus; Henriksen, Ulrik Birk; Bentzen, Jens Dall

    2002-01-01

    Baghouse filters and cartridge filters were tested online with wood gas from a two stage down draft gasifier. The gas contained soot and very low levels (10-30 mg/Nm³) of tar. Particle collection efficiencies were above 95%. Continuous operation with cheap self cleaning baghouse filters were test...

  17. 49 CFR 173.63 - Packaging exceptions.

    Science.gov (United States)

    2010-10-01

    ... transport personnel to remote work sites, such as offshore drilling units. (b) Cartridges, small arms, and... than 1 g explosive (excluding ignition and delay charges) that are electric blasting caps with leg wires 4 feet long or longer, delay connectors in plastic sheaths, or blasting caps with empty plastic...

  18. An Evaluation of Illicit Stimulants and Metabolites in Wastewa ter Effluent and the Wisconsin River Along the Central Wisconsin River Basin

    Directory of Open Access Journals (Sweden)

    Erik S. Hendrickson

    2015-09-01

    Full Text Available The goals of the study were to develop a method for extracting and quantifying illicit stimulants and metabolites, methamphetamine, amphetamine, cocaine, and benzoylecogonine from wastewater effluent and surface water grab samples, and evaluate Central Wisconsin wastewater treatment plant’s (WWTP removal efficiency of compounds of interest. The method created used HLB solid-phase extraction (SPE cartridges to extract substances of interest and High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC/MS/MS for quantification and qualification. All four wastewater effluent samples and three Wisconsin River samples had quantifiable concentrations of at least one analyte. Conclusions derived from the study were: The method created is effective for separating, quantifying, and identifying amphetamine, cocaine, and benzoylecognine from wastewater effluent and surface water grab samples, and each illicit stimulant and metabolite analyzed in this study were all quantified in wastewater effluent, indicating these compounds have the ability to survive WWTP.

  19. Long term substitution treatment (maintenance treatment of opioid dependent persons

    Directory of Open Access Journals (Sweden)

    Wirl, Charlotte

    2007-03-01

    Full Text Available Health political background: Methadone substitution treatment in Germany is introduced in 1988 in the framework of a scientific pilot study in North Rhein Westphalia. Recent statistics show that by now a broad offer of substitution treatment exists. From 1 June 2002 to 31 December 2003 113,000 substitution treatments have been recorded as being started of which around 56,000 have been recorded as ongoing treatments by 1 December 2003. Scientific background: Substitution treatment (treatment of opioid-dependent persons using substitution substances is one part of addiction treatment. Its goals are harm reduction and the stabilisation of opioid dependent persons. Integration of opioid-dependent persons in a treatment-setting, reduction of consumption of psychoactive substances, reduction of risk behaviour (primarily related to infectious diseases, decrease of mortality and improvements concerning the social, psychic and physic situation are seen as a success of substitution treatment as maintenance therapy. Research questions: The aim of this HTA report is to investigate which indicators can be used to evaluate the effectiveness of substitution treatment. Based on these indicators an evaluation of the medical, social and economical benefit of substitution treatment - also in relation to abstinence oriented treatment - is carried out. Methods: A systematic literature search was performed in 31 international databases which yielded 2451 articles with publication date between 1995 and February 2005. Results: After a twofold selection process 32 publications were included for assessment and 276 publications were used as background literature. Despite serious restrictions due to selection bias and dropout in most studies focusing on substitution treatment, reduction of consumption of illegal opioids, reduction of risk behaviour, criminal behaviour, mortality and incidence of HIV can be seen as an empirically proven success of substitution treatment

  20. Quality control studies of 99Mo used in 99Mo/99mTc generators produced at IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A.

    2015-01-01

    99m Tc is the most used radionuclide in nuclear medicine. In Brazil, the 99 Mo/ 99m Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing 99 Mo from different suppliers. 99 Mo (t 1/2 = 66 h) is a fission product of 235 U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [ 99 Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for 99 Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of 99 Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of 99 Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of 99 Mo from 131 I (other contaminant) are also proposed. (author)

  1. System for portable nucleic acid testing in low resource settings

    Science.gov (United States)

    Lu, Hsiang-Wei; Roskos, Kristina; Hickerson, Anna I.; Carey, Thomas; Niemz, Angelika

    2013-03-01

    Our overall goal is to enable timely diagnosis of infectious diseases through nucleic acid testing at the point-of-care and in low resource settings, via a compact system that integrates nucleic acid sample preparation, isothermal DNA amplification, and nucleic acid lateral flow (NALF) detection. We herein present an interim milestone, the design of the amplification and detection subsystem, and the characterization of thermal and fluidic control and assay execution within this system. Using an earlier prototype of the amplification and detection unit, comprised of a disposable cartridge containing flexible pouches, passive valves, and electrolysis-driven pumps, in conjunction with a small heater, we have demonstrated successful execution of an established and clinically validated isothermal loop-mediated amplification (LAMP) reaction targeting Mycobacterium tuberculosis (M.tb) DNA, coupled to NALF detection. The refined design presented herein incorporates miniaturized and integrated electrolytic pumps, novel passive valves, overall design changes to facilitate integration with an upstream sample preparation unit, and a refined instrument design that automates pumping, heating, and timing. Nucleic acid amplification occurs in a two-layer pouch that facilitates fluid handling and appropriate thermal control. The disposable cartridge is manufactured using low-cost and scalable techniques and forms a closed system to prevent workplace contamination by amplicons. In a parallel effort, we are developing a sample preparation unit based on similar design principles, which performs mechanical lysis of mycobacteria and DNA extraction from liquefied and disinfected sputum. Our next step is to combine sample preparation, amplification, and detection in a final integrated cartridge and device, to enable fully automated sample-in to answer-out diagnosis of active tuberculosis in primary care facilities of low-resource and high-burden countries.

  2. Multiplex Biosensing Based on Highly Sensitive Magnetic Nanolabel Quantification: Rapid Detection of Botulinum Neurotoxins A, B, and E in Liquids.

    Science.gov (United States)

    Orlov, Alexey V; Znoyko, Sergey L; Cherkasov, Vladimir R; Nikitin, Maxim P; Nikitin, Petr I

    2016-11-01

    We present a multiplex quantitative lateral flow (LF) assay for simultaneous on-site detection of botulinum neurotoxin (BoNT) types A, B, and E in complex matrixes, which is innovative by virtually no sacrifice in performance while transition from the single-plex assays and by characteristics on the level of laboratory quantitative methods. The novel approach to easy multiplexing is realized via joining an on-demand set of single-plex LF strips, which employ magnetic nanolabels, into a miniature cylinder cartridge that mimics LF strip during all assay stages. The cartridge is read out by an original portable multichannel reader based on the magnetic particle quantification technique. The developed reader offers the unmatched 60 zmol detection limit and 7-order linear dynamic range for volumetric registration of magnetic labels inside a cartridge of several millimeters in diameter regardless of its optical transparency. Each of the test strips, developed here as building blocks for the multiplex assay, can be used "as is" for autonomous quantitative single-plex detection with the same measuring setup, exhibiting the limits of detection (LOD) of 0.22, 0.11, and 0.32 ng/mL for BoNT-A, -B, and -E, respectively. The proposed multiplex assay has demonstrated the remarkably similar LOD values of 0.20, 0.12, 0.35 ng/mL under the same conditions. The multiplex assay performance was successfully validated by BoNT detection in milk and apple and orange juices. The developed methods can be extended to other proteins and used for rapid multianalyte tests for point-of-care in vitro diagnostics, food analysis, biosafety and environmental monitoring, forensics, and security, etc.

  3. Preliminary field evaluation of high efficiency steel filters

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Larsen, G.; Lopez, R. [Lawrence Livermore National Laboratory, CA (United States)] [and others

    1995-02-01

    We have conducted an evaluation of two high efficiency steel filters in the exhaust of an uranium oxide grit blaster at the Y-12 Plant in Oak Ridge Tennessee. The filters were installed in a specially designed filter housing with a reverse air-pulse cleaning system for automatically cleaning the filters in-place. Previous tests conducted on the same filters and housing at LLNL under controlled conditions using Arizona road dust showed good cleanability with reverse air pulses. Two high efficiency steel filters, containing 64 pleated cartridge elements housed in the standard 2` x 2` x 1` HEPA frame, were evaluated in the filter test housing using a 1,000 cfm slip stream containing a high concentration of depleted uranium oxide dust. One filter had the pleated cartridges manufactured to our specifications by the Pall Corporation and the other by Memtec Corporation. Test results showed both filters had a rapid increase in pressure drop with time, and reverse air pulses could not decrease the pressure drop. We suspected moisture accumulation in the filters was the problem since there were heavy rains during the evaluations, and the pressure drop of the Memtec filter decreased dramatically after passing clean, dry air through the filter and after the filter sat idle for one week. Subsequent laboratory tests on a single filter cartridge confirmed that water accumulation in the filter was responsible for the increase in filter pressure drop and the inability to lower the pressure drop by reverse air pulses. No effort was made to identify the source of the water accumulation and correct the problem because the available funds were exhausted.

  4. Applications of surface metrology in firearm identification

    International Nuclear Information System (INIS)

    Zheng, X; Soons, J; Vorburger, T V; Song, J; Renegar, T; Thompson, R

    2014-01-01

    Surface metrology is commonly used to characterize functional engineering surfaces. The technologies developed offer opportunities to improve forensic toolmark identification. Toolmarks are created when a hard surface, the tool, comes into contact with a softer surface and causes plastic deformation. Toolmarks are commonly found on fired bullets and cartridge cases. Trained firearms examiners use these toolmarks to link an evidence bullet or cartridge case to a specific firearm, which can lead to a criminal conviction. Currently, identification is typically based on qualitative visual comparison by a trained examiner using a comparison microscope. In 2009, a report by the National Academies called this method into question. Amongst other issues, they questioned the objectivity of visual toolmark identification by firearms examiners. The National Academies recommended the development of objective toolmark identification criteria and confidence limits. The National Institute of Standards and Technology (NIST) have applied its experience in surface metrology to develop objective identification criteria, measurement methods, and reference artefacts for toolmark identification. NIST developed the Standard Reference Material SRM 2460 standard bullet and SRM 2461 standard cartridge case to facilitate quality control and traceability of identifications performed in crime laboratories. Objectivity is improved through measurement of surface topography and application of unambiguous surface similarity metrics, such as the maximum value (ACCF MAX ) of the areal cross correlation function. Case studies were performed on consecutively manufactured tools, such as gun barrels and breech faces, to demonstrate that, even in this worst case scenario, all the tested tools imparted unique surface topographies that were identifiable. These studies provide scientific support for toolmark evidence admissibility in criminal court cases. (paper)

  5. [AIT (Adolescent Identity Treatment) - an Integrative Treatment Model for the Treatment of Personality Disorders].

    Science.gov (United States)

    Schlüter-Müller, Susanne

    2017-07-01

    AIT (Adolescent Identity Treatment) - an Integrative Treatment Model for the Treatment of Personality Disorders Personality disorders are patterns of maladaptive personality traits that have an impact on the individual throughout the life span. Borderline Personality Disorder (BPD) is a very severe, but treatable mental disorder. Identity disturbance is seen as the central construct for detecting severe personality pathology - and, most notably, borderline personality disorder - in adults and adolescents. Crises in the development of identity usually resolve into a normal and consolidated identity with flexible and adaptive functioning whereas identity diffusion is viewed as a lack of integration of the concept of the self and significant others. It is seen as the basis for subsequent personality pathology, including that of borderline personality disorder. Although BPD has its onset in adolescence and emerging adulthood the diagnosis is often delayed. In most cases, specific treatment is only offered late in the course of the disorder and to relatively few individuals. Adolescent Identity Treatment (AIT) is a treatment model that focuses on identity pathology as the core characteristic of personality disorders. This model integrates specific techniques for the treatment of adolescent personality pathology on the background of object-relation theories and modified elements of Transference-Focused Psychotherapy. Moreover, psychoeducation, a behavior-oriented homeplan and intensive family work is part of AIT.

  6. A Cultural Resources Survey of Arlington Revetment and LSU Berm Levee Improvement Item, East Baton Rouge Parish Louisiana

    Science.gov (United States)

    1993-07-01

    Light gm Slas 14 14 Lis Smm pmlew aumk Simm Milk glass 1 Modern brown glass I Olive glass _ Tin cm key 11 Shotg cartridge 1 Slate 1 Mortar 1 1 Piece of...Parish, Louisiana. Anthropological Report No. 1. Archaeological Survey and Antiquities Commission, Department of Culture, Recreation and Tourism , Baton

  7. Integrated Project Management: A Case Study in Integrating Cost, Schedule, Technical, and Risk Areas

    Science.gov (United States)

    Smith, Greg

    2004-01-01

    This viewgraph presentation describes a case study as a model for integrated project management. The ISS Program Office (ISSPO) developed replacement fluid filtration cartridges in house for the International Space Station (ISS). The presentation includes a step-by-step procedure and organizational charts for how the fluid filtration problem was approached.

  8. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  9. Hunting Intensity in the Suhuma Forest Reserve in the Sefwi Wiawso ...

    African Journals Online (AJOL)

    Hunting intensity in the Suhuma Forest Reserve (SFR) in the Sefwi Wiawso District of the Western Region of Ghana has been investigated. The methodology involved the recording of signs of hunting activity using linetransects, and interviews with hunters. A total of 157 spent cartridges, 21 wire snares, presence of 17 ...

  10. Computational Fluid Dynamics at work - Design and Optimization of Microfluidic Applications

    DEFF Research Database (Denmark)

    Krühne, Ulrich; Bodla, Vijaya Krishna; Møllenbach, Jacob

    2012-01-01

    and a simple biological model. The result is a suggestion of an improved geometry design. In the second case study a microfluidic cartridge of a novel automated in vitro fertilization device is presented, where the CFD model has supported the fluidic design of the microfluidic network in which the stem cells...

  11. 29 CFR 1926.904 - Storage of explosives and blasting agents.

    Science.gov (United States)

    2010-07-01

    ..., electric blasting caps, detonating primers, and primed cartridges shall not be stored in the same magazine... feet of explosives and detonator storage magazine. (d) No explosives or blasting agents shall be... 29 Labor 8 2010-07-01 2010-07-01 false Storage of explosives and blasting agents. 1926.904 Section...

  12. Multidisciplinary treatment

    International Nuclear Information System (INIS)

    Hayabuchi, Naofumi; Jingu, Kenichi; Matsuura, Keiichi

    1985-01-01

    Multidisciplinary treatment for malignant lymphoma is reported in terms of indication, current status, and outcome of this approach to Hodgkin's disease (HD) and non-Hodgkin's lymphomas (NLH). HD is considered to be most successfully managed with multidisciplinary treatment. Success of treatment of HD in European countries and the US, which has resulted from accurate staging of HD and developments in radiotherapy and chemotherapy, is reviewed in the literature. Problems in the treatment of HD in Japan are presented. A treatment policy for NHL is discussed according to the original site, i.e. lymph nodes, Waldeyer's ring or other sites of tumor involvement. (Namekawa, K.)

  13. Update on insulin treatment for dogs and cats: insulin dosing pens and more

    Directory of Open Access Journals (Sweden)

    Thompson A

    2015-04-01

    Full Text Available Ann Thompson,1 Patty Lathan,2 Linda Fleeman3 1School of Veterinary Science, The University of Queensland, Gatton, QLD, Australia; 2College of Veterinary Medicine Mississippi State University, Starkville, MS, USA; 3Animal Diabetes Australia, Melbourne, VIC, Australia Abstract: Insulin therapy is still the primary therapy for all diabetic dogs and cats. Several insulin options are available for each species, including veterinary registered products and human insulin preparations. The insulin chosen depends on the individual patient's requirements. Intermediate-acting insulin is usually the first choice for dogs, and longer-acting insulin is the first choice for cats. Once the insulin type is chosen, the best method of insulin administration should be considered. Traditionally, insulin vials and syringes have been used, but insulin pen devices have recently entered the veterinary market. Pens have different handling requirements when compared with standard insulin vials including: storage out of the refrigerator for some insulin preparations once pen cartridges are in use; priming of the pen to ensure a full dose of insulin is administered; and holding the pen device in place for several seconds during the injection. Many different types of pen devices are available, with features such as half-unit dosing, large dials for visually impaired people, and memory that can display the last time and dose of insulin administered. Insulin pens come in both reusable and disposable options. Pens have several benefits over syringes, including improved dose accuracy, especially for low insulin doses. Keywords: diabetes, mellitus, canine, feline, NPH, glargine, porcine lente

  14. Study of sources terms and medical radioactivity transfer in the waste water system of the town of Toulouse

    International Nuclear Information System (INIS)

    Debayle, C.

    2004-01-01

    It was demonstrated that the health establishments we studied implement means of radiation protection in accordance with the regulations and the recommendations of the circular D.G.S./D.H.O.S. in 2001. However, some exceeding of the average guide value recommended to the emissary of nuclear medicine services for iodine 131 were observed. The hypothesis we can suggest in view of the results is the recommendation to separate urines from feces induces the presence of iodine 131 because of the direct release of feces in the sewerage. On this base it would be interesting to consider the systematic storage of feces in tank at the nuclear medicine services exit, in conditions allowing to limit the nosocomial risk and to realize the earliest possible decay. In any event, it is important to survey these releases with devices for continuous measurement and not by point sampling to better understand the mechanisms. Finally, it might be worth exploring the possibilities of wastewater treatment through activated carbon cartridges and then limit the radioactive releases coming in the wastewater treatment plant. This would have for consequences to reduce the radioactivity transferred in the two units of muds storage and incineration. (N.C.)

  15. MSWT-01, an alternative in combining Production Based Education (PBE) and student CSR program in Polman

    Science.gov (United States)

    Ananto, Gamawan; Setiawan, Albertus B.; Z, Darman M.

    2014-06-01

    MSWT-01, Mobile Surface Water Treatment, producing 1m3 per hour, is an alternative for providing clean water in flood disaster areas, and was developed at Bandung State Polytechnic for Manufacturing (Polman) as a part of institution research project. The combination of cartridge or membrane technology such as carbon block, MF, UF and filtration media is used for this machine, instead of coagulation-flocculation with chemical addition, due to emergency purposes related with its treatment processing time. The idea is that MSWT could be combined with Production Based Education (PBE) concept in Polman as a vocational education institution and students 'CSR', students social activities. With the number of implementation trials in real flood area condition, MSWT will be developed further based on the technical output result. The manufacturing process for improving or adding necessary features could be implemented as a student's project in PBE system. This might be an ideal combination alternative for such vocational institution that students get the product media for their PBE program and implement their work as a defined social activity. They will learn and experience related technical matters and more social interactions with the people and other disaster stakeholder as well.

  16. [Treatment of chronic bovine endometritis and factors for treatment success].

    Science.gov (United States)

    Feldmann, M; Tenhagen genannt Emming, S; Hoedemaker, M

    2005-01-01

    In a controlled field trial, 178 dairy cows with chronic endometritis and at least 21 days in lactation were randomly assigned to four different treatment groups: prostaglandin F2alpha intramuscularly (PG, 5 mg dinoprost (5 ml Dinolytic), n = 51), intrauterine antibiotics (AB; 400 mg ampicillin + 800 oxacillin (20 ml Totocillin), n = 49), intrauterine antiseptics (AS; 100 ml 4% Lotagen, n = 50); control (C, no initial treatment, n = 28). Before treatment, uterine swabs for bacteriologic examination and blood samples for determination of serum progesterone concentrations were collected. Two weeks following the first treatment, cows were reexamined. In case no clinical cure was diagnosed, treatment was repeated and control cows were treated for the first time with one of the three treatments mentioned above. The four treatment groups did not differ with respect to the clinical cure or reproductive performance. Therefore, factors that might have an influence on clinical cure and fertility were evaluated. With increasing duration of lactation, the clinical cure after a single treatment increased significantly over all treatment groups from 59.5% (treatment before day 42 postpartum) to 79.6% (treatment following day 42 postpartum) (P conception rate and a lower pregnancy index were obtained when the treatment was performed following day 42 postpartum (P size had a negative effect on clinical cure over all groups (first treatment clinical cure: 68.2% (small uteri) vs 44.4% (large uteri); P 0.05). Isolation of Arcanobacterium (A.) pyogenes negatively influenced first treatment clinical cure over all treatment groups (79.0% vs 31.5%) and within treatment groups (P conception increased compared with the other treatment groups, when A. pyogenes was detected. Isolation of unspecific bacteria and the presence or absence of a corpus luteum only had minor effects over all and within the PG, AS and C group. Within the AB group, presence of luteal tissue was connected with a

  17. [Headache Treatment].

    Science.gov (United States)

    Diener, Hans Christoph; Holle-Lee, Dagny; Nägel, Steffen; Gaul, Charly

    2017-03-01

    A precondition for the successful treatment of headaches is the correct headache diagnosis. Triptans are effective for attack treatment of migraine and cluster headache. However, there are not effective for the treatment of tension-type headache. For the prevention of frequent episodic migraine betablockers, flunarizine, topiramate and amitriptyline are recommended. For the prevention of chronic migraine evidence is only available for onabotulinumtoxinA and topiramate. For prophylactic treatment of tension-type headaches tricyclic antidepressants are used. In cluster headache verapamil (in combination with steroids) is the most frequently used prophylactic agent. This article focusses on the current acute and prophylactic treatment of common headache syndromes. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Tuberculosis Treatment

    African Journals Online (AJOL)

    Tuberculosis Treatment, Lusaka, Zambia. 1. 2. 2. 3. 3 ... TB treatment has contributed to the steady rise of TB incidence in ... respondents (89.4%) had positive attitude towards TB treatment ..... respondents described feelings of depression, anger and apathy .... Journal of Personality and Social Psychology,. 1979, 37:1-11.

  19. 27 CFR 70.445 - Commerce in explosives.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Commerce in explosives. 70... Cartridges, and Explosives § 70.445 Commerce in explosives. Part 55 of title 27 CFR contains the regulations..., explosives, (b) Permits for users who buy or transport explosives in interstate or foreign commerce, (c...

  20. Routine plasma analysis for 2-[18F]fluorotyrosine by SAX-cartridges

    International Nuclear Information System (INIS)

    Kling, P.; Coenen, H.H.; Stoecklin, G.

    1990-01-01

    There is a great necessity for simple, reliable, and fast methods of plasma analysis. While HPLC is generally the most effective method, it is rather time consuming and expensive in a routine setting with numerous plasma samples. The authors have developed a new method for determination of the amino acid analogue 2-[ 18 F]fluorotyrosine using SAX columns (Adsorbex R SAX, 400 mg, Merck). The results obtained agree within 5% with those determined by reverse phase HPLC

  1. Determination of decamethylcyclopentasiloxane in air using commercial solid phase extraction cartridges.

    Science.gov (United States)

    Kierkegaard, Amelie; McLachlan, Michael S

    2010-05-21

    Decamethylcyclopentasiloxane (D(5)), a high production volume chemical used in personal care products, has been designated for regulation in Canada and is under review in the EU because of concerns about its persistence and potential for bioaccumulation in the environment. D(5) is a volatile compound expected to be found primarily in air, but there is little information on atmospheric concentrations due to the lack of sensitive analytical methods. Here a simple and sensitive method to determine D(5) in ambient air is presented. The challenge in the environmental analysis of D(5) is avoiding contamination. Our method is based on the high trapping efficiency of the sorbent Isolute ENV+, combined with a comparably high sampling rate. A small amount of sorbent (10 mg) is eluted in a small volume of n-hexane (0.1-0.6 mL), which is injected onto a GC/MS system without further processing. The simplicity of the method enables the use of a field blank for every sample to trace contamination. The method provides low limits of quantification (approximately 0.3 ng/m(3)), good repeatability and limited breakthrough (approximately 1%). By lowering the limit of quantification compared to published work by almost two orders of magnitude, it became possible to quantify D(5) in ambient air at locations remote from strong point sources. The concentrations at a rural Swedish site ranged from 0.7 to 8 ng/m(3) over a period of 4 months. 2010 Elsevier B.V. All rights reserved.

  2. Medication-Assisted Treatment For Opioid Addiction in Opioid Treatment Programs. Treatment Improvement Protocol (TIP) Series 43

    Science.gov (United States)

    Tinkler, Emily; Vallejos Bartlett, Catalina; Brooks, Margaret; Gilbert, Johnatnan Max; Henderson, Randi; Shuman, Deborah, J.

    2005-01-01

    TIP 43 provides best-practice guidelines for medication-assisted treatment of opioid addiction in opioid treatment programs (OTPs). The primary intended audience for this volume is substance abuse treatment providers and administrators who work in OTPs. Recommendations in the TIP are based on both an analysis of current research and determinations…

  3. Analysis of {sup 210}Pb in water samples with plastic scintillation resins

    Energy Technology Data Exchange (ETDEWEB)

    Lluch, E.; Barrera, J. [Department of Analytical Chemistry, University of Barcelona, Martí i Franqués, 1-11, E-08028, Barcelona (Spain); Tarancón, A., E-mail: alex.tarancon@ub.edu [Department of Analytical Chemistry, University of Barcelona, Martí i Franqués, 1-11, E-08028, Barcelona (Spain); Bagán, H. [Department of Pure and Applied Biochemistry, Lund University, Getingevägen 60, Hus II, 22100 SE, Lund (Sweden); García, J.F. [Department of Analytical Chemistry, University of Barcelona, Martí i Franqués, 1-11, E-08028, Barcelona (Spain)

    2016-10-12

    {sup 210}Pb is a radioactive lead isotope present in the environment as member of the {sup 238}U decay chain. Since it is a relatively long-lived radionuclide (T{sub 1/2} = 22.2 years), its analysis is of interest in radiation protection and the geochronology of sediments and artwork. Here, we present a method for analysing {sup 210}Pb using plastic scintillation resins (PSresins) packaged in solid-phase extraction columns (SPE cartridge). The advantages of this method are its selectivity, the low limit of detection, as well as reductions in the amount of time and reagents required for analysis and the quantity of waste generated. The PSresins used in this study were composed of a selective extractant (4′,4″(5″)-Di-tert-butyldicyclohexano-18-crown-6 in 1-octanol) covering the surface of plastic scintillation microspheres. Once the amount of extractant (1:1/4) and medium of separation (2 M HNO{sub 3}) were optimised, PSresins in SPE cartridges were calibrated with a standard solution of {sup 210}Pb. {sup 210}Pb could be fully separated from its daughters, {sup 210}Bi and {sup 210}Po, with a recovery value of 91(3)% and detection efficiency of 44(3)%. Three spiked water samples (one underground and two river water samples) were analysed in triplicates with deviations lower than 10%, demonstrating the validity of the PS resin method for {sup 210}Pb analysis. - Highlights: • A plastic scintillation resin for selective analysis of {sup 210}Pb has been developed. • A commercial SPE cartridge has been use for separation and scintillation counting. • {sup 210}Pb separation from {sup 210}Bi and {sup 210}Po is achieved with a 91(3)% of recovery. • The method is valid for analysis of {sup 210}Pb in river water samples.

  4. Challenges constraining access to insulin in the private-sector market of Delhi, India.

    Science.gov (United States)

    Sharma, Abhishek; Kaplan, Warren A

    2016-01-01

    India's majority of patients-including those living with diabetes-seek healthcare in the private sector through out-of-pocket (OOP) payments. We studied access to insulin in the private-sector market of Delhi state, India. A modified World Health Organization/Health Action International (WHO/HAI) standard survey to assess insulin availability and prices, and qualitative interviews with insulin retailers (pharmacists) and wholesalers to understand insulin market dynamics. In 40 pharmacy outlets analysed, mean availability of the human and analogue insulins on the 2013 Delhi essential medicine list was 44.4% and 13.1%, respectively. 82% of pharmacies had domestically manufactured human insulin phials, primarily was made in India under licence to overseas pharmaceutical companies. Analogue insulin was only in cartridge and pen forms that were 4.42 and 5.81 times, respectively, the price of human insulin phials. Domestically manufactured human phial and cartridge insulin (produced for foreign and Indian companies) was less expensive than their imported counterparts. The lowest paid unskilled government worker in Delhi would work about 1.5 and 8.6 days, respectively, to be able to pay OOP for a monthly supply of human phial and analogue cartridge insulin. Interviews suggest that the Delhi insulin market is dominated by a few multinational companies that import and/or license in-country production. Several factors influence insulin uptake by patients, including doctor's prescribing preference. Wholesalers have negative perceptions about domestic insulin manufacturing. The Delhi insulin market is an oligopoly with limited market competition. Increasing competition from Indian companies is going to require some additional policies, not presently in place. As more Indian companies produce biosimilars, brand substitution policies are needed to be able to benefit from market competition.

  5. Influencing Factors for the Microstructure and Mechanical Properties of Micro Porous Titanium Manufactured by Metal Injection Molding

    Directory of Open Access Journals (Sweden)

    Zhen Lu

    2016-04-01

    Full Text Available Porous titanium is a new structural and functional material. It is widely used in many fields since it integrates the properties of biomaterials with those of metallic foam. A new technology that combines both the preparation and forming of porous materials has been proposed in this paper. Moreover, a new solder was developed that could be employed in the joining of porous materials. Influencing factors for microstructure and mechanical properties of the parent material and joint interface are identified. Metal injection molding (MIM technology was used for fabricating porous materials. The feedstock for injection molding of porous titanium powders was prepared from titanium powders and a polymer-based binder system. In addition, the proportion of powder loading and binders was optimized. Through MIM technology, a porous titanium filter cartridge was prepared. For the purpose of investigating the thermal debinding technology of the filter cartridge, effects of the sintering temperature on the porosity, morphology of micropores and mechanical properties were analyzed. It could be found that when the sintering temperature increased, the relative density, bending and compression strength of the components also increased. Moreover, the porosity reached 32.28% when the sintering temperature was 1000 °C. The microstructure morphology indicated that micropores connected with each other. Meanwhile, the strength of the components was relatively high, i.e., the bending and compression strength was 65 and 60 MPa, respectively. By investigating the joining technology of porous filter cartridges, the ideal components of the solder and pressure were determined. Further research revealed that the micropore structure of the joint interface is the same as that of the parent material, and that the bending strength of the joint interface is 40 MPa.

  6. Assessment of platelet function in healthy sedated cats using three whole blood platelet function tests.

    Science.gov (United States)

    Ho, Kimberly K; Abrams-Ogg, Anthony C G; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L

    2015-05-01

    The objectives of this study were to establish feline references intervals for 3 commercial whole blood platelet function test analyzer systems: Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), Platelet Function Analyzer-100 (PF: Siemens Canada, Mississauga, Ontario, Canada), and Plateletworks Combo-25 kit (PW; Helena Laboratories, Beaumont, TX). Venipuncture was performed on 55 healthy sedated cats, and platelet aggregation in response to adenosine diphosphate (ADP), collagen (COL), and arachidonic acid (AA; MP only) was assessed using citrated blood. For the MP analyzer, median (95% confidence intervals [CIs]) area under curve (Units) for ADP, COL, and AA agonists were 87 (11-176), 81 (32-129), and 91 (59-129), respectively. For the PF analyzer, median (95% CIs) closure time, using COL-ADP cartridges, was 69 (46-89) sec. For the PW assay, median (95% CIs) percent aggregations for ADP and COL agonists were 71 (18-92) and 49 (9-96), respectively, using impedance hematology analyzer platelet counts, and 94 (25-98) and 68 (14-119), respectively, using flow cytometry hematology analyzer platelet counts. There were low correlations between the PF analyzer (COL-ADP cartridge) and MP analyzer (COL agonist; ρ = 0.11), and between the PF analyzer (COL-ADP cartridge) and PW assay (COL agonist using impedance platelet counts; ρ = 0.14). The PW assay percent aggregations using impedance and flow cytometric platelet counts were correlated for both ADP (ρ = 0.64) and COL (ρ = 0.64) agonists. Platelet function testing using these tests are feasible in cats, but 95% CIs are wide, so single results may be difficult to interpret. Platelet counting by impedance or flow cytometry may be used for the PW assay but are not interchangeable. © 2015 The Author(s).

  7. Quality control studies of {sup 99}Mo used in {sup 99}Mo/{sup 99m}Tc generators produced at IPEN/CNEN-SP, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A., E-mail: daphnesaid@usp.br, E-mail: taniabrambilla@yahoo.com.br, E-mail: mmatsuda@ipen.br, E-mail: jaosso@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    {sup 99m}Tc is the most used radionuclide in nuclear medicine. In Brazil, the {sup 99}Mo/{sup 99m}Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing {sup 99}Mo from different suppliers. {sup 99}Mo (t{sub 1/2} = 66 h) is a fission product of {sup 235}U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [{sup 99}Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for {sup 99}Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of {sup 99}Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of {sup 99}Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of {sup 99}Mo from {sup 131}I (other contaminant) are also proposed. (author)

  8. Optimization of hydrophilic interaction liquid chromatography/mass spectrometry and development of solid-phase extraction for the determination of paralytic shellfish poisoning toxins.

    Science.gov (United States)

    Turrell, Elizabeth; Stobo, Lesley; Lacaze, Jean-Pierre; Piletsky, Sergey; Piletska, Elena

    2008-01-01

    The combination of hydrophilic interaction liquid chromatography (HILIC) and liquid chromatography/mass spectrometry (LC/MS) for the determination of paralytic shellfish poisoning (PSP) toxins has been proposed for use in routine monitoring of shellfish. In this study, methods for the detection of multiple PSP toxins [saxitoxin (STX), neosaxitoxin (NEO), decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNEO), gonyautoxins 1-5 (GTX1, GTX2, GTX3, GTX4, GTX5), decarbamoyl gonyautoxins (dcGTX2 and dcGTX3), and the N-sulfocarbamoyl C toxins (C1 and C2)] were optimized using single (MS) and triple quadrupole (MS/MS) instruments. Chromatographic separation of the toxins was achieved by using a TSK-gel Amide-80 analytical column, although superior chromatography was observed through application of a ZIC-HILIC column. Preparative procedures used to clean up shellfish extracts and concentrate PSP toxins prior to analysis were investigated. The capacity of computationally designed polymeric (CDP) materials and HILIC solid-phase extraction (SPE) cartridges to retain highly polar PSP toxins was explored. Three CDP materials and 2 HILIC cartridges were assessed for the extraction of PSP toxins from aqueous solution. Screening of the CDPs showed that all tested polymers adsorbed PSP toxins. A variety of elution procedures were examined, with dilute 0.01% acetic acid providing optimum recovery from a CDP based on 2-(trifluoromethyl)acrylic acid as the monomer. ZIC-HILIC SPE cartridges were superior to the PolyLC equivalent, with recoveries ranging from 70 to 112% (ZIC-HILIC) and 0 to 90% (PolyLC) depending on the PSP toxin. It is proposed that optimized SPE and HILIC-MS methods can be applied for the quantitative determination of PSP toxins in shellfish.

  9. Signal processing to evaluate parameters affecting SPE for multi-residue analysis of personal care products.

    Science.gov (United States)

    Pietrogrande, Maria Chiara; Basaglia, Giulia; Dondi, Francesco

    2009-05-01

    This paper discusses the development of a comprehensive method for the simultaneous analysis of personal care products (PCPs) based on SPE and GC-MS. The method was developed on 29 target compounds to represent PCPs belonging to different chemical classes: surfactants in detergents (alkyl benzenes), fragrances in cosmetics (nitro and polycyclic musks), antioxidants and preservatives (phenols), plasticizers (phthalates) displaying a wide range of volatility, polarity, water solubility. In addition to the conventional C(18) stationary phase, a surface modified styrene divinylbenzene polymeric phase (Strata X SPE cartridge) has been investigated as suitable for the simultaneous extraction of several PCPs with polar and non-polar characteristics. For both sorbents different solvent compositions and eluting conditions were tested and compared in order to achieve high extraction efficiency for as many sample components as possible. Comparison of the behavior of the two cartridges reveals that, overall, Strata-X provides better efficiency with extraction recovery higher than 70% for most of the PCPs investigated. The best results were obtained under the following operative conditions: an evaporation temperature of 40 degrees C, elution on Strata-X cartridge using a volume of 15 mL of ethyl acetate (EA) as solvent and operating with slow flow rate (-10 KPa). In addition to the conventional method based on peak integration, a chemometric approach based on the computation of the experimental autocovariance function (EACVF(tot)) was applied to the complex GC-MS signal: the percentage recovery and information on peak abundance distribution can be evaluated for each procedure step. The PC-based signal processing proved very helpful in assisting the development of the analytical procedure, since it saves labor and time and increases result reliability in handling GC complex signals.

  10. MO-DE-207B-04: Impact of Reconstruction Field of View On Radiomics Features in Computed Tomography (CT) Using a Texture Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Shafiq ul Hassan, M; Zhang, G; Oliver, J; Moros, E [H Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Department of Physics, University of South Florida (United States); Latifi, K; Hunt, D; Guzman, R; Balagurunathan, Y; Gillies, R [H Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Mackin, D; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To investigate the impact of reconstruction Field of View on Radiomics features in computed tomography (CT) using a texture phantom. Methods: A rectangular Credence Cartridge Radiomics (CCR) phantom, composed of 10 different cartridges, was scanned on four different CT scanners from two manufacturers. A pre-defined scanning protocol was adopted for consistency. The slice thickness and reconstruction interval of 1.5 mm was used on all scanners. The reconstruction FOV was varied to result a voxel size ranging from 0.38 to 0.98 mm. A spherical region of interest (ROI) was contoured on the shredded rubber cartridge from CCR phantom CT scans. Ninety three Radiomics features were extracted from ROI using an in-house program. These include 10 shape, 22 intensity, 26 GLCM, 11 GLZSM, 11 RLM, 5 NGTDM and 8 fractal dimensional features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) was calculated for each feature group. Each group was further classified according to the COV by calculating the percentage of features in each of the following categories: COV≤ 5%, between 5 and 10% and ≥ 10%. Results: Shape features were the most robust, as expected, because of the spherical contouring of ROI. Intensity features were the second most robust with 54.5 to 64% of features with COV < 5%. GLCM features ranged from 31 to 35% for the same category. RLM features were sensitive to specific scanner and 5% variability was 9 to 54%. Almost all GLZM and NGTDM features showed COV ≥10% among the scanners. The dependence of fractal dimensions features on FOV was not consistent across different scanners. Conclusion: We concluded that reconstruction FOV greatly influence Radiomics features. The GLZSM and NGTDM are highly sensitive to FOV. funded in part by Grant NIH/NCI R01CA190105-01.

  11. Development of radiometric methods for radioactive waste characterization

    International Nuclear Information System (INIS)

    Tessaro, Ana Paula Gimenes

    2015-01-01

    The admission of radioactive waste in a final repository depends among other things on the knowledge of the radioisotopic inventory of the waste. To obtain this information it is necessary make the primary characterization of the waste so that it is composition is known, to guide the next steps of radioactive waste management. Filter cartridges that are used in the water polishing system of IEA-R1 research reactor is one of these wastes. The IEA-R1 is a pool-type research reactor, operating between 2 and 5 MW that uses water as coolant, moderator and biological shield. Besides research, it is used for production of radioisotopes and irradiation of samples with neutron and gamma beams. It is located in the Nuclear and Energy Research Institute at the University of Sao Paulo campus. The filter cartridges are used to retain particles that are suspended in the cooling water. When filters become saturated and are unable to maintain the flow within the established limits, they are replaced and disposed of as radioactive waste. After a period of decay, they are sent to the Radioactive Waste Management Department. The aim of this work is to present the studies to determine the activity of gamma emitters present in the cartridge filters. The activities were calculated using the dose rates measured with hand held detectors, after the ratios of the emission rates of photons were evaluated by gamma spectrometry, by the Point Kernel method, which correlates the activity of a source with dose rates at various distances. The method described can be used to determine routinely the radioactive inventory of these filters, avoiding the necessity of destructive radiochemical analysis, or the necessity of calibrating the geometry of measurement. (author)

  12. Airborne aldehydes in cabin-air of commercial aircraft: Measurement by HPLC with UV absorbance detection of 2,4-dinitrophenylhydrazones.

    Science.gov (United States)

    Rosenberger, Wolfgang; Beckmann, Bibiana; Wrbitzky, Renate

    2016-04-15

    This paper presents the strategy and results of in-flight measurements of airborne aldehydes during normal operation and reported "smell events" on commercial aircraft. The aldehyde-measurement is a part of a large-scale study on cabin-air quality. The aims of this study were to describe cabin-air quality in general and to detect chemical abnormalities during the so-called "smell-events". Adsorption and derivatization of airborne aldehydes on 2,4-dinitrophenylhydrazine coated silica gel (DNPH-cartridge) was applied using tailor-made sampling kits. Samples were collected with battery supplied personal air sampling pumps during different flight phases. Furthermore, the influence of ozone was investigated by simultaneous sampling with and without ozone absorption unit (ozone converter) assembled to the DNPH-cartridges and found to be negligible. The method was validated for 14 aldehydes and found to be precise (RSD, 5.5-10.6%) and accurate (recovery, 98-103 %), with LOD levels being 0.3-0.6 μg/m(3). According to occupational exposure limits (OEL) or indoor air guidelines no unusual or noticeable aldehyde pollution was observed. In total, 353 aldehyde samples were taken from two types of aircraft. Formaldehyde (overall average 5.7 μg/m(3), overall median 4.9 μg/m(3), range 0.4-44 μg/m(3)), acetaldehyde (overall average 6.5 μg/m(3), overall median 4.6, range 0.3-90 μg/m(3)) and mostly very low concentrations of other aldehydes were measured on 108 flights. Simultaneous adsorption and derivatization of airborne aldehydes on DNPH-cartridges to the Schiff bases and their HPLC analysis with UV absorbance detection is a useful method to measure aldehydes in cabin-air of commercial aircraft. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Challenges constraining access to insulin in the private-sector market of Delhi, India

    Science.gov (United States)

    Kaplan, Warren A

    2016-01-01

    Objective India's majority of patients—including those living with diabetes—seek healthcare in the private sector through out-of-pocket (OOP) payments. We studied access to insulin in the private-sector market of Delhi state, India. Methods A modified World Health Organization/Health Action International (WHO/HAI) standard survey to assess insulin availability and prices, and qualitative interviews with insulin retailers (pharmacists) and wholesalers to understand insulin market dynamics. Results In 40 pharmacy outlets analysed, mean availability of the human and analogue insulins on the 2013 Delhi essential medicine list was 44.4% and 13.1%, respectively. 82% of pharmacies had domestically manufactured human insulin phials, primarily was made in India under licence to overseas pharmaceutical companies. Analogue insulin was only in cartridge and pen forms that were 4.42 and 5.81 times, respectively, the price of human insulin phials. Domestically manufactured human phial and cartridge insulin (produced for foreign and Indian companies) was less expensive than their imported counterparts. The lowest paid unskilled government worker in Delhi would work about 1.5 and 8.6 days, respectively, to be able to pay OOP for a monthly supply of human phial and analogue cartridge insulin. Interviews suggest that the Delhi insulin market is dominated by a few multinational companies that import and/or license in-country production. Several factors influence insulin uptake by patients, including doctor's prescribing preference. Wholesalers have negative perceptions about domestic insulin manufacturing. Conclusions The Delhi insulin market is an oligopoly with limited market competition. Increasing competition from Indian companies is going to require some additional policies, not presently in place. As more Indian companies produce biosimilars, brand substitution policies are needed to be able to benefit from market competition. PMID:28588966

  14. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  15. [Preprosthetic orthodontic treatments

    NARCIS (Netherlands)

    Prahl-Andersen, B.; Prahl, C.; Baat, C. de; Creugers, N.H.J.

    2014-01-01

    The objective of a preprosthetic orthodontic treatment is to position the teeth in such a way that a treatment with (fixed) dental prostheses is made possible or simplified or to affect the result of this treatment positively. Conceivable preprosthetic orthodontic treatments are: correcting primary

  16. Palladium on Carbon-Catalyzed Suzuki-Miyaura Coupling Reaction Using an Efficient and Continuous Flow System

    Directory of Open Access Journals (Sweden)

    Tomohiro Hattori

    2015-01-01

    Full Text Available The continuous flow Suzuki-Miyaura reaction between various haloarenes and arylboronic acids was successfully achieved within only ca. 20 s during the single-pass through a cartridge filled with palladium on carbon (Pd/C. No palladium leaching was observed in the collected reaction solution by atomic absorption spectrometry (detection limit: 1 ppm.

  17. Reduction of treatment delivery variances with a computer-controlled treatment delivery system

    International Nuclear Information System (INIS)

    Fraass, B.A.; Lash, K.L.; Matrone, G.M.; Lichter, A.S.

    1997-01-01

    Purpose: To analyze treatment delivery variances for 3-D conformal therapy performed at various levels of treatment delivery automation, ranging from manual field setup to virtually complete computer-controlled treatment delivery using a computer-controlled conformal radiotherapy system. Materials and Methods: All external beam treatments performed in our department during six months of 1996 were analyzed to study treatment delivery variances versus treatment complexity. Treatments for 505 patients (40,641 individual treatment ports) on four treatment machines were studied. All treatment variances noted by treatment therapists or quality assurance reviews (39 in all) were analyzed. Machines 'M1' (CLinac (6(100))) and 'M2' (CLinac 1800) were operated in a standard manual setup mode, with no record and verify system (R/V). Machines 'M3' (CLinac 2100CD/MLC) and ''M4'' (MM50 racetrack microtron system with MLC) treated patients under the control of a computer-controlled conformal radiotherapy system (CCRS) which 1) downloads the treatment delivery plan from the planning system, 2) performs some (or all) of the machine set-up and treatment delivery for each field, 3) monitors treatment delivery, 4) records all treatment parameters, and 5) notes exceptions to the electronically-prescribed plan. Complete external computer control is not available on M3, so it uses as many CCRS features as possible, while M4 operates completely under CCRS control and performs semi-automated and automated multi-segment intensity modulated treatments. Analysis of treatment complexity was based on numbers of fields, individual segments (ports), non-axial and non-coplanar plans, multi-segment intensity modulation, and pseudo-isocentric treatments (and other plans with computer-controlled table motions). Treatment delivery time was obtained from the computerized scheduling system (for manual treatments) or from CCRS system logs. Treatment therapists rotate among the machines, so this analysis

  18. Lithium Pellet Injector Development for NSTX

    International Nuclear Information System (INIS)

    Gettelfinger, G.; Dong, J.; Gernhardt, R.; Kugel, H.; Sichta, P.; Timberlake, J.

    2003-01-01

    A pellet injector suitable for the injection of lithium and other low-Z pellets of varying mass into plasmas at precise velocities from 5 to 500 m/s is being developed for use on NSTX (National Spherical Torus Experiment). The ability to inject low-Z impurities will significantly expand NSTX experimental capability for a broad range of diagnostic and operational applications. The architecture employs a pellet-carrying cartridge propelled through a guide tube by deuterium gas. Abrupt deceleration of the cartridge at the end of the guide tube results in the pellet continuing along its intended path, thereby giving controlled reproducible velocities for a variety of pellets materials and a reduced gas load to the torus. The planned injector assembly has four hundred guide tubes contained in a rotating magazine with eight tubes provided for injection into plasmas. A PC-based control system is being developed as well and will be described elsewhere in these Proceedings. The development path and mechanical performance of the injector will be described

  19. [Determination method of polysorbates in powdered soup by HPLC].

    Science.gov (United States)

    Takeda, Y; Abe, Y; Ishiwata, H; Yamada, T

    2001-04-01

    A method for qualitative and quantitative analyses of polysorbates in powdered soup by HPLC was studied. Polysorbates in samples were extracted with acetonitrile after rinsing with n-hexane to remove fats and oils. The extract was cleaned up using a Bond Elut silica gel cartridge (500 mg). The cartridge was washed with ethyl acetate and polysorbates were eluted with a small amount of acetonitrile-methanol (1:2) mixture. The eluate was treated with cobalt thiocyanate solution to form a blue complex with polysorbate. In order to determine polysorbate, the complex was subjected to HPLC with a GPC column, using a mixture of acetonitrile-water (95:5) as a mobile phase, with a detection wavelength of 620 nm. The recoveries of polysorbate 80 added to powdered soups were more than 75% and the determination limit was 0.04 mg/g. When the proposed method was applied to the determination of polysorbates in 16 commercial samples of powdered soup for instant noodles and seasoning consomme, no polysorbates were detected in any sample.

  20. Method and apparatus for extruding thermoplastic material

    International Nuclear Information System (INIS)

    McKelvey, J.M.

    1985-01-01

    A gear pump assisted screw conveyor extrusion system utilizing a cartridge heating device disposed axially within the screw and having the drives for the gear pump and the screw correlated in speed to create relatively little pressure in the thermoplastic material being extruded such that relatively little mechanical working thereof occurs. The thermoplastic material is melted in the screw conveyor primarily by heat transfer from the cartridge heater and the gear pump is utilized for conveying the melted material under pressure to a subsequent work station. A relatively deep material-conveying spiral channel is provided in the screw for maximized extrusion output per revolution of the screw and minimized mechanical energy generation by the screw. A motionless mixer may be employed intermediate the screw and the work station to homogenize the melted material for reducing temperature gradients therein. The system advantageously is capable of extruding material at a substantially greater rate and a lower material temperature and with substantially increased power economy than conventional systems utilizing a high pressure, externally heated screw conveyor portion

  1. Changes in feedwater organic matter concentrations based on intake type and pretreatment processes at SWRO facilities, Red Sea, Saudi Arabia

    KAUST Repository

    Dehwah, Abdullah

    2015-03-01

    Transparent exopolymer particles (TEP), natural organic matter, and bacterial concentrations in feedwater are important factors that can lead to membrane biofouling in seawater reverse osmosis (SWRO) systems. Two methods for controlling these concentrations in the feedwater prior to pretreatment have been suggested; use of subsurface intake systems or placement of the intake at a greater depth in the sea. These proposed solutions were tested at two SWRO facilities located along the Red Sea of Saudi Arabia. A shallow well intake system was very effective in reducing the algae and bacterial concentrations and somewhat effective in reducing TEP concentrations. An intake placed at a depth of 9. m below the surface was found to have limited impact on improving water quality compared to a surface intake. The algae and bacteria concentration in the feedwater (deep) was lower compared to the surface seawater, but the overall TEP concentration was higher. Bacteria and TEP measurements made in the pretreatment process train in the plant and after the cartridge filters suggest that regrowth of bacteria is occurring within the cartridge filters.

  2. Development of a rapid LC-DAD/FLD method for the simultaneous determination of auxins and abscisic acid in plant extracts.

    Science.gov (United States)

    Bosco, Renato; Caser, Matteo; Vanara, Francesca; Scariot, Valentina

    2013-11-20

    Plant hormones play a crucial role in controlling plant growth and development. These groups of naturally occurring substances trigger physiological processes at very low concentrations, which mandate sensitive techniques for their quantitation. This paper describes a method to quantify endogenous (±)-2-cis-4-trans-abscisic acid, indole-3-acetic acid, indole-3-propionic acid, and indole-3-butyric acid. The method combines high-performance liquid chromatography (HPLC) with diode array and fluorescence detection in a single run. Hybrid tea rose 'Monferrato' matrices (leaves, petals, roots, seeds, androecium, gynoecium, and pollen) were used as references. Rose samples were separated and suspended in extracting methanol, after which (±)-2-cis-4-trans-abscisic acid and auxins were extracted by solvent extraction. Sample solutions were added first to cation solid phase extraction (SPE) cartridges and the eluates to anion SPE cartridges. The acidic hormones were bound to the last column and eluted with 5% phosphoric acid in methanol. Experimental results showed that this approach can be successfully applied to real samples and that sample preparation and total time for routine analysis can be greatly reduced.

  3. Miniaturization for Point-of-Care Analysis: Platform Technology for Almost Every Biomedical Assay.

    Science.gov (United States)

    Schumacher, Soeren; Sartorius, Dorian; Ehrentreich-Förster, Eva; Bier, Frank F

    2012-10-01

    Platform technologies for the changing need of diagnostics are one of the main challenges in medical device technology. From one point-of-view the demand for new and more versatile diagnostic is increasing due to a deeper knowledge of biomarkers and their combination with diseases. From another point-of-view a decentralization of diagnostics will occur since decisions can be made faster resulting in higher success of therapy. Hence, new types of technologies have to be established which enables a multiparameter analysis at the point-of-care. Within this review-like article a system called Fraunhofer ivD-platform is introduced. It consists of a credit-card sized cartridge with integrated reagents, sensors and pumps and a read-out/processing unit. Within the cartridge the assay runs fully automated within 15-20 minutes. Due to the open design of the platform different analyses such as antibody, serological or DNA-assays can be performed. Specific examples of these three different assay types are given to show the broad applicability of the system.

  4. Atomic pile Directorate, Department of Metallurgy, Departments of Technology, Department of Fuel Elements and Structures, Division of Study of Fuel Elements - Semi annual report on the 1968-10-1

    International Nuclear Information System (INIS)

    Arnaud, M.; Tortel, J.; Viallet, H.; Marinot, R.; Rulleau, A.; Lestiboudois, G.; Rousseau, G.; Faussat, A.; Ollier, H.; Truffert, J.; Ferrier, C.; Courcon, P.; Rendu, M.; Dieumegard, M.; Bret, A.

    1968-01-01

    This document gathers a set of reports of studies performed on nuclear fuel elements. The addressed topics are: creep behaviour of UMo and UMoAl tubes and pellets under the action of an external pressure (creep strength of tubes under external pressure, creep strength of pellets under external pressure, uncertainties on irradiation parameters in Pegase), problems related to centring devices (measurements and tests), irradiations of ring elements in power reactors, uranium/sheath metallurgical relationship for Bugey and influence of irradiation (cartridge behaviour in Pegase, long duration irradiation in power reactors, extrapolation in Bugey of results obtained in G2), theoretical study of kinetic oxidation phenomena in metal fuels, tests of leaking cartridges in EdF2, evolution of pressure in EL4 type irradiated fuel rods with ZrCu liners with respect to the conductivity integral, a focus on irradiations of Z0 type fuel elements in Pegase, cluster safety tests with uranium carbide in pile and out of pile, a review of studies performed on fuel elements with blowhole, and application of neutrography to fuel elements

  5. Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor

    Energy Technology Data Exchange (ETDEWEB)

    Milanez, Fernando H; Mantellil, Marcia H.B.; Borges, Thomaz P.F. [Santa Catarina Univ., Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica; Landa, Henrique G. de [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2005-07-01

    Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel design, the heat exchanger efficiency increases, and the thermal inertia decreases, compared to the conventional system. The new sealed concept of the chamber prevents water evaporation losses. (author)

  6. High capacity getter pump for UHV operation

    International Nuclear Information System (INIS)

    Manini, P.; Marino, M.; Belloni, F.; Porro, M.

    1993-01-01

    UHV pumps based on non-evaporable getter coated strips find widespread use in particle accelerators, synchrotron radiation machines and nuclear fusion experimental devices. Depending on the geometric constraints, pressure operation conditions and the foreseen gas loads, optimized getter structures, such as modules and cartridges, can be designed and assembled into a high-efficiency pump. In the present paper, the design and performance of a newly conceived High Capacity Getter Pump (HCGP) based on sintered getter bodies, in the shape of blades instead of strips, is illustrated. The porosity and the specific surface area of the blades and their arrangement in the cartridge have been optimized to significantly increase sorption capacity at a given speed. These pumps are well suited for those applications where a very high gas load is expected during the machine operation. The sintered getter bodies increase surface area and capacity, requiring less frequent reactivation and facilitating greater overall life of the pump. A discussion of the experimental results in terms of sorption speed and capacity for various gases is presented

  7. Evaluation of surface dose rate on C-14 scrubber and gas bag

    International Nuclear Information System (INIS)

    Gang, D. W.; Lee, H. S.; Lee, D. H.

    2003-01-01

    In CANDU(Canadian Deuterium Uranium) reactors, purge and discharge of moderator cover gas has been performed via vapor recovery system. The methods employed in C-14 removal are mainly based on reactions of CO 2 with absorber of adsorbent. In order to choose an optimum process, we should consider the characteristics of the process, such as, temperature, pressure, humidity etc. and surface dose rate on C-14 scrubber and gas bag to estimate job-related personnel doses. Assuming that the whole C-14 scrubber was completely replaced after one-cycle operation, and that its C-14 activity for one-cycle operation was 40 mCi, we calculated the surface dose rate at the six points of the C-14 scrubber. This calculation showed that the dose rate on the surface of cartridge was only 1.25μSυ/hγ because of low energy of β ray. It is concluded, therefore, that the cartridge change-out is safe because the operation of C-14 removal system causes only a small increase in dose rate

  8. Changes in feedwater organic matter concentrations based on intake type and pretreatment processes at SWRO facilities, Red Sea, Saudi Arabia

    KAUST Repository

    Dehwah, Abdullah; Li, Sheng; Almashharawi, Samir; Winters, Harvey; Missimer, Thomas M.

    2015-01-01

    Transparent exopolymer particles (TEP), natural organic matter, and bacterial concentrations in feedwater are important factors that can lead to membrane biofouling in seawater reverse osmosis (SWRO) systems. Two methods for controlling these concentrations in the feedwater prior to pretreatment have been suggested; use of subsurface intake systems or placement of the intake at a greater depth in the sea. These proposed solutions were tested at two SWRO facilities located along the Red Sea of Saudi Arabia. A shallow well intake system was very effective in reducing the algae and bacterial concentrations and somewhat effective in reducing TEP concentrations. An intake placed at a depth of 9. m below the surface was found to have limited impact on improving water quality compared to a surface intake. The algae and bacteria concentration in the feedwater (deep) was lower compared to the surface seawater, but the overall TEP concentration was higher. Bacteria and TEP measurements made in the pretreatment process train in the plant and after the cartridge filters suggest that regrowth of bacteria is occurring within the cartridge filters.

  9. Spent fuels conditioning and irradiated nuclear fuel elements examination: the STAR facility and its abilities

    Energy Technology Data Exchange (ETDEWEB)

    Boussard, F.; Huillery, R. [CEA Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. d`Etudes des Combustibles; Averseng, J.L.; Serpantie, J.P. [Novatome Industries, 92 - Le Plessis-Robinson (France)

    1994-12-31

    This paper is a presentation of the STAR facility, a high activity laboratory located in Cadarache Nuclear Research Center (France). The purpose of the STAR facility and of the associated processes, is the treatment, cleaning and conditioning of spent fuels from Gas Cooled Reactors (GCR) and in particular of about 2300 spent GCR fuel cartridges irradiated more than 20 years ago in Electricite de France (EDF) or CEA Uranium Graphite GCR. The processes are: to separate the nuclear fuel from the clad remains, to chemically stabilize the nuclear material and to condition it in sealed canisters. An additional objective of STAR consists in non-destructive or destructive examinations and tests on PWR rods or FBR pins in the frame of fuel development programs. The paper describes the STAR facility conceptual design (safety design rules, hot cells..) and the different options corresponding to the GCR reconditioning process and to further research and development works on various fuel types. (J.S.). 3 figs.

  10. In-depth analyses of organic matters in a full-scale seawater desalination plant and an autopsy of reverse osmosis membrane

    KAUST Repository

    Jeong, Sanghyun; Naidu, Gayathri; Vollprecht, Robert; Leiknes, TorOve; Vigneswaran, Saravanamuthu

    2016-01-01

    In order to facilitate the global performance of seawater reverse osmosis (SWRO) systems, it is important to improve the feed water quality before it enters the RO. Currently, many desalination plants experience production losses due to incidents of organic and biofouling. Consequently, monitoring or characterizing the pretreatment step using more advanced organic and biological parameters are required for better operation to lessen fouling issues. In this study, the performance of pretreatment processes (including coagulation, dual media filtration (DMF), polishing with cartridge filter (CF) coupled with anti-scalant) used at Perth Seawater Desalination Plant (PSDP) located in Western Australia were characterized in terms of organic and biological fouling parameters. These analyses were carried out using liquid chromatography with organic carbon detector (LC-OCD), three dimensional-fluorescence excitation emission matrix (3D-FEEM) and assimilable organic carbon (AOC). Furthermore, the used (exhausted) RO membrane and CF were autopsied so that the fates and behaviors of organic foulants in these treatment systems could be better understood.

  11. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  12. In-depth analyses of organic matters in a full-scale seawater desalination plant and an autopsy of reverse osmosis membrane

    KAUST Repository

    Jeong, Sanghyun

    2016-02-17

    In order to facilitate the global performance of seawater reverse osmosis (SWRO) systems, it is important to improve the feed water quality before it enters the RO. Currently, many desalination plants experience production losses due to incidents of organic and biofouling. Consequently, monitoring or characterizing the pretreatment step using more advanced organic and biological parameters are required for better operation to lessen fouling issues. In this study, the performance of pretreatment processes (including coagulation, dual media filtration (DMF), polishing with cartridge filter (CF) coupled with anti-scalant) used at Perth Seawater Desalination Plant (PSDP) located in Western Australia were characterized in terms of organic and biological fouling parameters. These analyses were carried out using liquid chromatography with organic carbon detector (LC-OCD), three dimensional-fluorescence excitation emission matrix (3D-FEEM) and assimilable organic carbon (AOC). Furthermore, the used (exhausted) RO membrane and CF were autopsied so that the fates and behaviors of organic foulants in these treatment systems could be better understood.

  13. Determination of Ketorolac in the Effluent from a Hospital Treating Plant and Kinetics Study of Its Photolytic Degradation

    Directory of Open Access Journals (Sweden)

    Hector Hugo Ortega Soto

    2017-01-01

    Full Text Available In this work, two specific, sensitive, and rapid analytical methods were developed. One of them was for the determination of ketorolac in a hospital wastewater treatment plant where there is no interference with other organic substances; the other one was for the determination of the degradation kinetics in aqueous medium. Ketorolac was extracted from wastewater samples through solid-phase extraction (SPE cartridges, then it was identified and quantified by high-performance liquid chromatography (HPLC. Ketorolac was detected in concentrations between 0.1376 and 0.2667 μg/L. Photolytic degradation was performed on aqueous solutions of ketorolac tromethamine reference substance, at a concentration of 50 μg/mL. Samples were in direct contact with ultraviolet light in a dark chamber, equipped with two mercury lamps (254 nm at a radiation source of 15 W. The results of the photolytic degradation were adjusted to a first-order model, obtaining a half-life of 4.8 hrs.

  14. Spent fuels conditioning and irradiated nuclear fuel elements examination: the STAR facility and its abilities

    International Nuclear Information System (INIS)

    Boussard, F.; Huillery, R.

    1994-01-01

    This paper is a presentation of the STAR facility, a high activity laboratory located in Cadarache Nuclear Research Center (France). The purpose of the STAR facility and of the associated processes, is the treatment, cleaning and conditioning of spent fuels from Gas Cooled Reactors (GCR) and in particular of about 2300 spent GCR fuel cartridges irradiated more than 20 years ago in Electricite de France (EDF) or CEA Uranium Graphite GCR. The processes are: to separate the nuclear fuel from the clad remains, to chemically stabilize the nuclear material and to condition it in sealed canisters. An additional objective of STAR consists in non-destructive or destructive examinations and tests on PWR rods or FBR pins in the frame of fuel development programs. The paper describes the STAR facility conceptual design (safety design rules, hot cells..) and the different options corresponding to the GCR reconditioning process and to further research and development works on various fuel types. (J.S.). 3 figs

  15. Teaching Treatment Planning.

    Science.gov (United States)

    Seligman, Linda

    1993-01-01

    Describes approach to teaching treatment planning that author has used successfully in both seminars and graduate courses. Clarifies nature and importance of systematic treatment planning, then describes context in which treatment planning seems more effectively taught, and concludes with step-by-step plan for teaching treatment planning.…

  16. Antihypertensive treatment

    DEFF Research Database (Denmark)

    Christensen, Cramer; Mogensen, C E

    1987-01-01

    This study was undertaken to clarify whether antihypertensive treatment has any effect on the rate of progression of kidney disease in patients with incipient diabetic nephropathy. Six insulin-dependent diabetic men with incipient nephropathy (urinary albumin excretion above 15 micrograms....../min and total protein excretion below 0.5 g/24 h) were first given metoprolol (200 mg daily) with the subsequent addition of hydroflumethiazide. At the start of antihypertensive treatment, mean patient age was 32 +/- 4.2 years (SD) and mean duration of diabetes was 18 +/- 1.2 years. The patients were followed...... with repeated measurements of urinary albumin excretion for a mean of 5.4 +/- 3.1 years prior to, and for 4.7 +/- 1.3 years (SD) during treatment. Mean arterial blood pressure declined significantly during treatment, e.g., the values at 6 months before initiation of treatment being compared with values during...

  17. Mandometer Treatment Not Superior to Treatment as Usual for Anorexia Nervosa

    NARCIS (Netherlands)

    van Elburg, Annemarie A.; Hillebrand, Jacquelien J. G.; Huyser, Chaim; Snoek, Maartje; Kas, Martien; Hoek, Hans W.; Adan, Roger A. H.

    Objective: A comparison of the efficacy of a novel treatment method for anorexia nervosa (AN), the Mandometer treatment (MT), with treatment as usual (TAU). Method: During treatment data were collected to determine weight recovery and outcome as assessed by the Morgan Russell Outcome Assessment

  18. Analysis of External Treatment Methods and Technical Characteristics of External Treatment

    Science.gov (United States)

    Zhang, Rui; Miao, Mingsan; Bai, Ming

    2018-01-01

    Chinese medicine external therapy is a treatment method of Chinese medicine with Chinese characteristics. The effect of traditional Chinese medicine external treatment, convenient operation, external treatment and technology has great prospects for development. The traditional Chinese medicine external treatment method and technical characteristics were analyzed.

  19. Barriers to Implementing Treatment Integrity Procedures: Survey of Treatment Outcome Researchers

    Science.gov (United States)

    Perepletchikova, Francheska; Hilt, Lori M.; Chereji, Elizabeth; Kazdin, Alan E.

    2009-01-01

    Treatment integrity refers to implementing interventions as intended. Treatment integrity is critically important for experimental validity and for drawing valid inferences regarding the relationship between treatment and outcome. Yet, it is rarely adequately addressed in psychotherapy research. The authors examined barriers to treatment integrity…

  20. Gambling Disorder: Exploring Pre-treatment and In-treatment Dropout Predictors. A UK Study.

    Science.gov (United States)

    Ronzitti, Silvia; Soldini, Emiliano; Smith, Neil; Clerici, Massimo; Bowden-Jones, Henrietta

    2017-12-01

    The aim of this study was to identify predictors of treatment dropout in a sample of gamblers attending a specialist clinic for gambling disorder. We analysed data on 846 treatment-seeking pathological gamblers. Firstly, we investigated differences in socio-demographic and clinical variables between treatment completers and pre-treatment dropouts, as well as between treatment completers and during-treatment dropouts. Subsequently, variables were entered into a multinomial logistic regression model to identify significant predictors of pre-treatment and in-treatment dropout. Overall, 44.8% of clients did not complete the treatment: 27.4% dropped out before starting it, while 17.4% dropped out during the treatment. Younger age and use of drugs were associated with pre-treatment dropout, while family history of gambling disorder, a lower PGSI score, and being a smoker were related with in-treatment dropout. Our findings suggest that pre-treatment dropouts differ from in-treatment dropouts, and, thus, further research will benefit from considering these groups separately. In addition, this newly gained knowledge will also be helpful in increasing treatment retention in specific subgroups of problem gamblers.