WorldWideScience

Sample records for pv pruni strain

  1. Chemical characterization of Xanthan biopolymers synthesized by Xanthomonas campestris pv pruni strains; Caracterizacao quimica de biopolimeros sintetizados por Xanthomonas campestris pv pruni

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Angelita da S.; Vendruscolo, Claire T.; Furlan, Ligia [Universidade Federal de Pelotas, RS (Brazil). Centro de Biotecnologia]. E-mail: angelita@ufpel.tche.br; claire@ufpel.tche.br; ligia@ufpel.tche.br; Galland, Griselda [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Inst. de Qumica

    2001-07-01

    In this work we describe the characterisation of Xanthan biopolymers synthesized by two Xanthomonas campestris pv pruni strains, in aerobic fermentation. By chromatography on TLC we could notice the presence of Mannose monomer in higher proportion in the 82 strain with relation to the another ones. The viscosity results showed the temperature dependence. The 06 and 82 strains had their viscosity increased whereas for the 87 strain we could observe a reduction with temperature increasing. The {sup 13}C NMR spectrum of 87 strain showed the characteristic signals at approximately 92.8, 70.4 and 61.4 ppm, attributed to C1, C4 and C6 from glucose monomer, with higher intensity. (author)

  2. Influence of agitation and aeration in xanthan production by Xanthomonas campestris pv pruni strain 101 Influencia de la agitación y la aireación en la producción de xantano por Xanthomonas campestris pv. pruni cepa 101

    Directory of Open Access Journals (Sweden)

    C. D. Borges

    2008-06-01

    Full Text Available Production, viscosity, and chemical composition of xanthan synthesized by bacterium Xanthomonas campestris pv pruni strain 101 were evaluated in bioreactor systems. During the process, the volumetric oxygen mass transfer coefficient (kLa and the biomass were determined and the pH was monitored. The cultures were grown in a 3 l bioreactor, with aeration and agitation varying as follows: conditions (A 300 rpm, 3 vvm and (B 200 rpm, 2 vvm, at 28 °C. Our results showed that gum production was dependent on kLa, with a maximum yield of 8.15 g/l at 300 rpm, 3 vvm, 54 h of fermentation, kLa 21.4/h, while biomass was not affected. All aqueous solutions of 3% (w/v xanthans synthesized showed a pseudoplastic behavior. The highest viscosity was reached under the strongest aeration/agitation conditions. All xanthan samples contained glucose, mannose, rhamnose, and glucuronic acid as their main components. The highest agitation and aeration rates used under condition A (300 rpm and 3 vvm favorably influenced the yield and viscosity of the xanthan produced by bacterium X. campestris pv pruni 101 at different fermentation times.Se evaluó la producción, viscosidad y composición química del xantano sintetizado por la bacteria Xanthomonas campestris pv. pruni cepa 101 en un fermentador. Durante el proceso se controló el pH y se determinaron el coeficiente de transferencia de masa de oxígeno (kLa y la producción de masa celular seca. Los cultivos se realizaron en un fermentador de 3 l variando la aireación y la agitación, en las siguientes condiciones: (A 300 rpm, 3 vvm y (B 200 rpm, 2 vvm; a 28 °C. Nuestros resultados mostraron que la producción de goma fue dependiente del kLa, con un rendimiento máximo de 8,15 g/l a 300 rpm y 3 vvm a las 54 h de fermentación, kLa de 21,4/h, mientras que la producción de biomasa no se afectó. Todas las soluciones acuosas de xantano al 3% (m/v sintetizadas presentaron comportamiento pseudoplástico. La mayor

  3. Structure and Origin of Xanthomonas arboricola pv. pruni Populations Causing Bacterial Spot of Stone Fruit Trees in Western Europe.

    Science.gov (United States)

    Boudon, Sylvain; Manceau, Charles; Nottéghem, Jean-Loup

    2005-09-01

    ABSTRACT Xanthomonas arboricola pv. pruni, the causal agent of bacterial spot on stone fruit, was found in 1995 in several orchards in southeastern France. We studied population genetics of this emerging pathogen in comparison with populations from the United States, where the disease was first described, and from Italy, where the disease has occurred since 1920. Four housekeeping genes (atpD, dnaK, efp, and glnA) and the intergenic transcribed spacer region were sequenced from a total of 3.9 kb of sequences, and fluorescent amplified fragment length polymorphism (FAFLP) analysis was performed. A collection of 64 X. arboricola pv. pruni strains, including 23 strains from France, was analyzed. The X. arboricola pv. pruni population had a low diversity because no sequence polymorphisms were observed. Population diversity revealed by FAFLP was lower for the West European population than for the American population. The same bacterial genotype was detected from five countries on three continents, a geographic distribution that can be explained by human-aided migration of bacteria. Our data support the hypothesis that the pathogen originated in the United States and subsequently has been disseminated to other stone-fruit-growing regions of the world. In France, emergence of this disease was due to a recent introduction of the most prevalent genotype of the bacterium found worldwide.

  4. Novel Rosaceae Plant Elicitor Peptides as sustainable tools to control Xanthomonas arboricola pv. pruni in Prunus spp

    OpenAIRE

    Ruiz Beltrán, Cristina; Nadal i Matamala, Anna; Montesinos Seguí, Emilio; Pla i de Solà-Morales, Maria

    2017-01-01

    Fruit crops are regarded as important health promoters and constitute a major part of global agricultural production, and Rosaceae species are of high economic impact. Their culture is threatened by bacterial diseases, which control is only based on preventive treatment with compounds with limited efficacy and a negative environmental impact. One of the most economically relevant examples is the pathogen Xanthomonas arboricola pv. pruni (Xap) affecting Prunus spp. Plant immune response agains...

  5. Evaluation of a real-time PCR and a loop-mediated isothermal amplification for detection of Xanthomonas arboricola pv. pruni in plant tissue samples

    NARCIS (Netherlands)

    Palacio-Bielsa, Ana; López-Soriano, Pablo; Bühlmann, Andreas; Doorn, van Joop; Pham, Khanh; Cambra, Miguel A.; Berruete, Isabel M.; Pothier, Joël F.; Duffy, Brion; Olmos, Antonio; López, María M.

    2015-01-01

    Operational capacity of real-time PCR and loop-mediated isothermal amplification (LAMP) diagnostic assays for detection of Xanthomonas arboricola pv. pruni was established in a ring-test involving four laboratories. Symptomatic and healthy almond leaf samples with two methods of sample

  6. Evaluation of a real-time PCR and a loop-mediated isothermal amplification for detection of Xanthomonas arboricola pv. pruni in plant tissue samples

    NARCIS (Netherlands)

    Palacio-Bielsa, Ana; López-Soriano, Pablo; Bühlmann, Andreas; Doorn, van Joop; Pham, Khanh; Cambra, Miguel A.; Berruete, Isabel M.; Pothier, Joël F.; Duffy, Brion; Olmos, Antonio; López, María M.

    2015-01-01

    Operational capacity of real-time PCR and loop-mediated isothermal amplification (LAMP) diagnostic assays for detection of Xanthomonas arboricola pv. pruni was established in a ring-test involving four laboratories. Symptomatic and healthy almond leaf samples with two methods of sample preparatio

  7. Novel Rosaceae plant elicitor peptides as sustainable tools to control Xanthomonas arboricola pv. pruni in Prunus spp.

    Science.gov (United States)

    Ruiz, Cristina; Nadal, Anna; Montesinos, Emilio; Pla, Maria

    2017-01-05

    Fruit crops are regarded as important health promoters and constitute a major part of global agricultural production, and Rosaceae species are of high economic impact. Their culture is threatened by bacterial diseases, whose control is based on preventative treatments using compounds of limited efficacy and negative environmental impact. One of the most economically relevant examples is the pathogen Xanthomonas arboricola pv. pruni (Xap) affecting Prunus spp. The plant immune response against pathogens can be triggered and amplified by plant elicitor peptides (Peps), perceived by specific receptors (PEPRs). Although they have been described in various angiosperms, scarce information is available on Rosaceae species. Here, we identified the Pep precursor (PROPEP), Pep and PEPR orthologues of 10 Rosaceae species and confirmed the presence of the Pep/PEPR system in this family. We showed the perception and elicitor activity of Rosaceae Peps using the Prunus-Xap pathosystem as proof-of-concept. Treatment with nanomolar doses of Peps induced the corresponding PROPEP and a set of defence-related genes in Prunus leaves, and enhanced resistance against Xap. Peps from the same species had the highest efficiencies. Rosaceae Peps could potentially be used to develop natural, targeted and environmentally friendly strategies to enhance the resistance of Prunus species against biotic attackers.

  8. 柰李细菌性黑斑病菌侵染过程研究%INFECTION PROCESS OF Xanthomonas arboricola pv. pruni ON NAI PLUM (Prunus salicina var. cordata )

    Institute of Scientific and Technical Information of China (English)

    戴良英; 高必达

    2001-01-01

    @@ The bacterial spot on Nai plum caused by Xanthomonas arboricola pv. pruni is an important disease in Hu nan Province, causing a considerable yield loss. Studies were carried out on this disease, such as field investiga tion on occurrence and development and integrated control. In this paper we report the fine structure study of the diseased tissues.

  9. Comportamento reológico de xantana produzida por Xanthomonas arboricola pv pruni para aplicação em fluido de perfuração de poços de petróleo Rheological behaviour of xanthan produced by Xanthomonas arboricola pv pruni for application in fluid of oil well perforation

    Directory of Open Access Journals (Sweden)

    Caroline D. Borges

    2009-06-01

    Full Text Available O trabalho objetivou avaliar xantanas produzidas por Xanthomonas arboricola pv pruni como viscosificante de fluido para aplicação na perfuração de poços de petróleo, comparando-as com três amostras comerciais utilizadas para este fim. Para isto, a viscosidade de soluções aquosas e salinas (NaCl, KCl e CaCl2 das diferentes xantanas, em distintas temperaturas (25, 45, 65 e 80 ºC, foi determinada em reômetro. Os parâmetros reológicos índice de consistência (K e o índice de fluxo (n foram obtidos pelo ajuste do modelo de Ostwald-de-Waelle. A força gel (G0, G10 e G30 foi determinada em viscosímetro, e a concentração de sais monovalentes (sódio e potássio e divalentes (cálcio e magnésio foi determinada em fotômetro de chama e em espectrômetro de absorção atômica, respectivamente. De uma forma geral, os resultados obtidos neste estudo mostram que as xantanas produzidas pelo patovar pruni, Xp 106-600 e Xp 115-600, por conterem baixa concentração de sais, apresentaram potencial para aplicação em fluido de perfuração de poços de petróleo, quando utilizada solução salina. Já os polímeros comerciais apresentaram melhores resultados quando utilizados em solução aquosa, pois continham alta concentração de sais.The aim of this work was to evaluate xanthans produced by Xanthomonas arboricola pv pruni to be used for increasing the viscosity of fluids applied in the perforation of oil wells, which were compared with three commercial samples. In order to do that, the viscosity of aqueous and saline solutions (NaCl, KCl and CaCl2 from different xanthans, at different temperatures (25, 45, 65 and 80 ºC, was determined in a rheometer. The rheological parameters consistency index (K and flow behaviour index (n were obtained by adjusting the data with the Ostwald-de-Waelle model. Gel strength (G0, G10 e G30 was determined in a viscometer, and the concentration of monovalent (sodium and potassium and divalent salts (calcium

  10. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France.

    Science.gov (United States)

    Cunty, Amandine; Cesbron, Sophie; Briand, Martial; Carrère, Sébastien; Poliakoff, Françoise; Jacques, Marie-Agnès; Manceau, Charles

    2016-01-01

    Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae.

  11. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France

    Directory of Open Access Journals (Sweden)

    Amandine Cunty

    Full Text Available ABSTRACT Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae.

  12. Comparative Genomic and Phenotypic Characterization of Pathogenic and Non-Pathogenic Strains of Xanthomonas arboricola Reveals Insights into the Infection Process of Bacterial Spot Disease of Stone Fruits.

    Science.gov (United States)

    Garita-Cambronero, Jerson; Palacio-Bielsa, Ana; López, María M; Cubero, Jaime

    2016-01-01

    Xanthomonas arboricola pv. pruni is the causal agent of bacterial spot disease of stone fruits, a quarantinable pathogen in several areas worldwide, including the European Union. In order to develop efficient control methods for this disease, it is necessary to improve the understanding of the key determinants associated with host restriction, colonization and the development of pathogenesis. After an initial characterization, by multilocus sequence analysis, of 15 strains of X. arboricola isolated from Prunus, one strain did not group into the pathovar pruni or into other pathovars of this species and therefore it was identified and defined as a X. arboricola pv. pruni look-a-like. This non-pathogenic strain and two typical strains of X. arboricola pv. pruni were selected for a whole genome and phenotype comparative analysis in features associated with the pathogenesis process in Xanthomonas. Comparative analysis among these bacterial strains isolated from Prunus spp. and the inclusion of 15 publicly available genome sequences from other pathogenic and non-pathogenic strains of X. arboricola revealed variations in the phenotype associated with variations in the profiles of TonB-dependent transporters, sensors of the two-component regulatory system, methyl accepting chemotaxis proteins, components of the flagella and the type IV pilus, as well as in the repertoire of cell-wall degrading enzymes and the components of the type III secretion system and related effectors. These variations provide a global overview of those mechanisms that could be associated with the development of bacterial spot disease. Additionally, it pointed out some features that might influence the host specificity and the variable virulence observed in X. arboricola.

  13. MicroHLPC determination of amygdalin in Semen pruni armeniacae and Semen pruni persicae.

    Science.gov (United States)

    He, L Y; Li, B M

    1988-11-01

    The application of micro HPLC to the determination of amygdalin in Semen pruni armeniacae and Semen pruni persicae is described. Amygdalin is separated at ambient temperature on a reversed phase column of U-Finepak SIL C18(150 x 0.5 mm) with methanol + water (25:75 v/v) as the mobile phase at a flow rate of 10 microL/min. The results are calculated by the internal standard method. The linear range is 1-7 micrograms. The CV and recovery of pure amygdalin are 1.47% (n = 10) and 98.13%, respectively. The results of analysis are lower than those obtained by TLC, but microHPLC is much simpler, faster, and more sensitive and reproducible than TLC.

  14. Genome Sequences of Two Pseudomonas syringae pv. tomato Race 1 Strains, Isolated from Tomato Fields in California

    OpenAIRE

    Thapa, Shree P.; Coaker, Gitta

    2016-01-01

    Pseudomonas syringae pv. tomato race 1 strains have evolved to overcome genetic resistance in tomato. Here, we present the draft genome sequences of two race 1 P. syringae pv. tomato strains, A9 and 407, isolated from diseased tomato plants in California.

  15. Molecular Characteristics of Pseudomonas syringae pv. actinidiae Strains Isolated in Korea and a Multiplex PCR Assay for Haplotype Differentiation

    Directory of Open Access Journals (Sweden)

    Hyun Seok Koh

    2014-03-01

    Full Text Available The molecular features of Pseudomonas syringae pv. actinidiae strains isolated in Korea were compared with strains isolated in Japan and Italy. Sequencing of eight P. syringae pv. actinidiae and three P. syringae pv. theae strains revealed a total of 44 single nucleotide polymorphisms across 4,818 bp of the concatenated alignment of nine genes. A multiplex PCR assay was developed for the detection of P. syringae pv. actinidiae and for the specific detection of recent haplotype strains other than strains isolated since the 1980s in Korea. The primer pair, designated as TacF and TacR, specifically amplified a 545-bp fragment with the genomic DNA of new haplotype of P. syringae pv. actinidiae strains. A multiplex PCR conducted with the TacF/TacR primer pair and the universal primer pair for all P. syringae pv. actinidiae strains can be simultaneously applied for the detection of P. syringae pv. actinidiae and for the differentiation of new haplotype strains.

  16. Complete Genome Sequence of Xanthomonas arboricola pv. juglandis 417, a Copper-Resistant Strain Isolated from Juglans regia L.

    Science.gov (United States)

    Pereira, Ulisses P; Gouran, Hossein; Nascimento, Rafael; Adaskaveg, James E; Goulart, Luiz Ricardo; Dandekar, Abhaya M

    2015-01-01

    Here, we report the complete genome sequence of Xanthomonas arboricola pv. juglandis 417, a copper-resistant strain isolated from a blighted walnut fruit (Juglans regia L. cv. Chandler). The genome consists of a single chromosome (5,218 kb).

  17. Molecular test to assign individuals within the Cacopsylla pruni complex.

    Directory of Open Access Journals (Sweden)

    Jean Peccoud

    Full Text Available Crop protection requires the accurate identification of disease vectors, a task that can be made difficult when these vectors encompass cryptic species. Here we developed a rapid molecular diagnostic test to identify individuals of Cacopsyllapruni (Scopoli, 1763 (Hemiptera: Psyllidae, the main vector of the European stone fruit yellows phytoplasma. This psyllid encompasses two highly divergent genetic groups that are morphologically similar and that are characterized by genotyping several microsatellite markers, a costly and time-consuming protocol. With the aim of developing species-specific PCR primers, we sequenced the Internal Transcribed Spacer 2 (ITS2 on a collection of C. pruni samples from France and other European countries. ITS2 sequences showed that the two genetic groups represent two highly divergent clades. This enabled us to develop specific primers for the assignment of individuals to either genetic group in a single PCR, based on ITS2 amplicon size. All previously assigned individuals yielded bands of expected sizes, and the PCR proved efficient on a larger sample of 799 individuals. Because none appeared heterozygous at the ITS2 locus (i.e., none produced two bands, we inferred that the genetic groups of C. pruni, whose distribution is partly sympatric, constitute biological species that have not exchanged genes for an extended period of time. Other psyllid species (Cacopsylla, Psylla, Triozidae and Aphalaridae failed to yield any amplicon. These primers are therefore unlikely to produce false positives and allow rapid assignment of C. pruni individuals to either cryptic species.

  18. Comparative genomic analysis of Xanthomonas axonopodis pv. citrumelo F1, which causes citrus bacterial spot disease, and related strains provides insights into virulence and host specificity.

    Science.gov (United States)

    Jalan, Neha; Aritua, Valente; Kumar, Dibyendu; Yu, Fahong; Jones, Jeffrey B; Graham, James H; Setubal, João C; Wang, Nian

    2011-11-01

    Xanthomonas axonopodis pv. citrumelo is a citrus pathogen causing citrus bacterial spot disease that is geographically restricted within the state of Florida. Illumina, 454 sequencing, and optical mapping were used to obtain a complete genome sequence of X. axonopodis pv. citrumelo strain F1, 4.9 Mb in size. The strain lacks plasmids, in contrast to other citrus Xanthomonas pathogens. Phylogenetic analysis revealed that this pathogen is very close to the tomato bacterial spot pathogen X. campestris pv. vesicatoria 85-10, with a completely different host range. We also compared X. axonopodis pv. citrumelo to the genome of citrus canker pathogen X. axonopodis pv. citri 306. Comparative genomic analysis showed differences in several gene clusters, like those for type III effectors, the type IV secretion system, lipopolysaccharide synthesis, and others. In addition to pthA, effectors such as xopE3, xopAI, and hrpW were absent from X. axonopodis pv. citrumelo while present in X. axonopodis pv. citri. These effectors might be responsible for survival and the low virulence of this pathogen on citrus compared to that of X. axonopodis pv. citri. We also identified unique effectors in X. axonopodis pv. citrumelo that may be related to the different host range as compared to that of X. axonopodis pv. citri. X. axonopodis pv. citrumelo also lacks various genes, such as syrE1, syrE2, and RTX toxin family genes, which were present in X. axonopodis pv. citri. These may be associated with the distinct virulences of X. axonopodis pv. citrumelo and X. axonopodis pv. citri. Comparison of the complete genome sequence of X. axonopodis pv. citrumelo to those of X. axonopodis pv. citri and X. campestris pv. vesicatoria provides valuable insights into the mechanism of bacterial virulence and host specificity.

  19. Comparative Genomic Analysis of Xanthomonas axonopodis pv. citrumelo F1, Which Causes Citrus Bacterial Spot Disease, and Related Strains Provides Insights into Virulence and Host Specificity ▿ #

    Science.gov (United States)

    Jalan, Neha; Aritua, Valente; Kumar, Dibyendu; Yu, Fahong; Jones, Jeffrey B.; Graham, James H.; Setubal, João C.; Wang, Nian

    2011-01-01

    Xanthomonas axonopodis pv. citrumelo is a citrus pathogen causing citrus bacterial spot disease that is geographically restricted within the state of Florida. Illumina, 454 sequencing, and optical mapping were used to obtain a complete genome sequence of X. axonopodis pv. citrumelo strain F1, 4.9 Mb in size. The strain lacks plasmids, in contrast to other citrus Xanthomonas pathogens. Phylogenetic analysis revealed that this pathogen is very close to the tomato bacterial spot pathogen X. campestris pv. vesicatoria 85-10, with a completely different host range. We also compared X. axonopodis pv. citrumelo to the genome of citrus canker pathogen X. axonopodis pv. citri 306. Comparative genomic analysis showed differences in several gene clusters, like those for type III effectors, the type IV secretion system, lipopolysaccharide synthesis, and others. In addition to pthA, effectors such as xopE3, xopAI, and hrpW were absent from X. axonopodis pv. citrumelo while present in X. axonopodis pv. citri. These effectors might be responsible for survival and the low virulence of this pathogen on citrus compared to that of X. axonopodis pv. citri. We also identified unique effectors in X. axonopodis pv. citrumelo that may be related to the different host range as compared to that of X. axonopodis pv. citri. X. axonopodis pv. citrumelo also lacks various genes, such as syrE1, syrE2, and RTX toxin family genes, which were present in X. axonopodis pv. citri. These may be associated with the distinct virulences of X. axonopodis pv. citrumelo and X. axonopodis pv. citri. Comparison of the complete genome sequence of X. axonopodis pv. citrumelo to those of X. axonopodis pv. citri and X. campestris pv. vesicatoria provides valuable insights into the mechanism of bacterial virulence and host specificity. PMID:21908674

  20. Complete Genome Sequences of Six Copper-Resistant Xanthomonas citri pv.?citri Strains Causing Asiatic Citrus Canker, Obtained Using Long-Read Technology

    OpenAIRE

    Richard, Damien; Boyer, Claudine; Vernière, Christian; Canteros, B.I.; Lefeuvre, Pierre; Pruvost, Olivier

    2017-01-01

    The gammaproteobacterium Xanthomonas citri pv. citri causes Asiatic citrus canker. Pathotype A strains have a broad host range, which includes most commercial citrus species, and they cause important economic losses worldwide. Control often relies on frequent copper sprays. We present here the complete genomes of six X. citri pv. citri copper-resistant strains. (Résumé d'auteur)

  1. Complete Genome Sequences of Six Copper-Resistant Xanthomonas citri pv. citri Strains Causing Asiatic Citrus Canker, Obtained Using Long-Read Technology

    Science.gov (United States)

    Richard, Damien; Boyer, Claudine; Vernière, Christian; Canteros, Blanca I.; Lefeuvre, Pierre

    2017-01-01

    ABSTRACT The gammaproteobacterium Xanthomonas citri pv. citri causes Asiatic citrus canker. Pathotype A strains have a broad host range, which includes most commercial citrus species, and they cause important economic losses worldwide. Control often relies on frequent copper sprays. We present here the complete genomes of six X. citri pv. citri copper-resistant strains. PMID:28336584

  2. Identification and molecular characterization of twin-arginine translocation system (Tat) in Xanthomonas oryzae pv. oryzae strain PXO99.

    Science.gov (United States)

    Chen, Lei; Hu, Baishi; Qian, Guoliang; Wang, Chen; Yang, Wanfeng; Han, Zhicheng; Liu, Fengquan

    2009-02-01

    Xanthomonas oryzae pv. oryzae causes bacterial leaf blight, one of the most widespread and destructive bacterial diseases in rice. This study identified and characterized the contribution of the twin-arginine translocation (Tat) pathway to motility, chemotaxis, extracellular polysaccharide (EPS) production and virulence in X. oryzae pv. oryzae strain PXO99. The tatC disruption mutant (strain TCM) of strain PXO99 were generated, and confirmed both by PCR and Southern blotting. Strain PXO99 cells were highly motile in NYGB 0.3% soft agar plate. In contrast, the tatC mutation impaired motility. Furthermore, strain TCM cells lacked detectable flagella and exhibited almost no chemotaxis toward glucose under aerobic conditions, indicating that the Tat secretion pathway contributed to flagellar biogenesis and chemotactic responses. It was also observed that strain TCM exhibited a reductive production of extracellular polysaccharide (EPS) and a significant reduction of virulence on rice plants when compared with the wild type PXO99. However, the tatC mutation in strain PXO99 did not affect growth rate and the ability to induce hypersensitive response (HR) in nonhost tobacco (Nicotiana tabacum L. cv. Samsun). Our findings indicated that the Tat system of X. oryzae pv. oryzae played an important role in the pathogen's virulence.

  3. Phytohormone production by strains of Pantoea agglomerans from knots on olive plants caused by Pseudomonas savastanoi pv. savastanoi

    OpenAIRE

    Cimmino, A; A. Andolfi; MARCHI, G.; Surico, G.; Evidente, A

    2006-01-01

    Pantoea agglomerans is a common epiphyte of many plant species, and it is associated with Pseudomonas savastanoi pv. savastanoi in young and apparently intact olive knots. Strains of P. agglomerans collected from various olive groves in central Italy were studied for their ability to accumulate plant growth substances in culture. All the strains produced indole-3-aldehyde, indole-3-ethanol and indole-3-acetic acid (IAA), this last compound in amounts (average 8.7 mg l-1) comparabl...

  4. [The gene wxcA of Xanthomonas campestris pv. campestris 8004 strain involved in EPS yield].

    Science.gov (United States)

    Lu, Guang-Tao; Tang, Ji-Liang; Wei, Guang-Ning; He, Yong-Qiang; Chen, Bao-Shan

    2004-07-01

    Xanthomonas campestris pv. campestris (Xcc), the pathogenic agent of black rot disease in cruciferous plants, produces large amount of extracellular polysaccharide (EPS), which has found wide applications in industry. For the great commercial value of the xanthan gum, many of the genes involved in EPS biosynthesis have been cloned and the mechanism of EPS biosynthesis also has been studied. In order to clone genes involved in EPS biosynthesis, Xcc wild-type strain 8004 was mutagenized with transposon Tn5 gusA5, and a number of EPS-defective mutants were isolated in our previous work. The Tn5 gusA5 inserted sites of these mutants were located by using thermal asymmetric interlaced PCR, and results showed that two EPS-defective mutants were insertion mutants of the gene wxcA which involved in lipopolysaccharide (LPS) biosynthesis. The gene wxcA involved in lipopolysaccharide biosynthesis but dose not extracellular polysaccharide in others' report. wxcA::Tn5 gusA5 mutant 021C12, the polar mutant, was complemented with recombinant plasmid pLATC8570 harboring an intact wxcA gene in this work, but the yield of EPS of the wxcA::Tn5 gusA5 mutant was not restored. In order to identify the function of wxcA gene of Xcc 8004 strain, the gene wxcA was deleted by gene replacement strategy, and the no-polar mutant of wxcA was obtained. DeltawxcA mutant strain, named Xcc 8570, was confirmed by using both PCR and southern analysis. Beside the LPS biosynthesis of deltawxcA mutant was affected, The EPS yield of deltawxcA mutant strain reduced by 50% as compared with the wild-type strain 8004. DeltawxcA mutant could be complemented in trans with the intact wxcA gene, and the EPS yield of the mutant was restored. The combined data showed that wxcA gene not only involved in LPS biosynthesis but also EPS yield in Xcc 8004 strain.

  5. Science Letters:Differentiation of xanthomonads causing the bacterial leaf spot of poinsettia in China from the pathotype strain of Xanthomonas axonopodis pv. Poinsettiicola

    Institute of Scientific and Technical Information of China (English)

    LI Bin; XIE Guan-lin; SWINGS J.

    2005-01-01

    In October 2003, a new bacterial disease with symptoms similar to those caused by Xanthomonas axonopodis pv.poinsettiicola was observed on poinsettia leaves at a flower nursery in Zhejiang Province of China. Three Xanthomonas strains were isolated from infected plants and classified as X. axonopodis. They were differentiated from the pathotype strain LMG849 of X. axonopodis pv. poinsettiicola causing bacterial leaf spot of poinsettia by comparison of pathogenicity, substrate utilization and BOX-PCR genomic fingerprints.

  6. Multilocus Sequence Typing Reveals Relevant Genetic Variation and Different Evolutionary Dynamics among Strains of Xanthomonas arboricola pv. juglandis

    Directory of Open Access Journals (Sweden)

    Marco Scortichini

    2010-11-01

    Full Text Available Forty-five Xanthomonas arboricola pv. juglandis (Xaj strains originating from Juglans regia cultivation in different countries were molecularly typed by means of MultiLocus Sequence Typing (MLST, using acnB, gapA, gyrB and rpoD gene fragments. A total of 2.5 kilobases was used to infer the phylogenetic relationship among the strains and possible recombination events. Haplotype diversity, linkage disequilibrium analysis, selection tests, gene flow estimates and codon adaptation index were also assessed. The dendrograms built by maximum likelihood with concatenated nucleotide and amino acid sequences revealed two major and two minor phylotypes. The same haplotype was found in strains originating from different continents, and different haplotypes were found in strains isolated in the same year from the same location. A recombination breakpoint was detected within the rpoD gene fragment. At the pathovar level, the Xaj populations studied here are clonal and under neutral selection. However, four Xaj strains isolated from walnut fruits with apical necrosis are under diversifying selection, suggesting a possible new adaptation. Gene flow estimates do not support the hypothesis of geographic isolation of the strains, even though the genetic diversity between the strains increases as the geographic distance between them increases. A triplet deletion, causing the absence of valine, was found in the rpoD fragment of all 45 Xaj strains when compared with X. axonopodis pv. citri strain 306. The codon adaptation index was high in all four genes studied, indicating a relevant metabolic activity.

  7. Phytohormone Production by Strains of Pantoea agglomerans from Knots on Olive Plants Caused by Pseudomonas savastanoi pv. savastanoi

    Directory of Open Access Journals (Sweden)

    A. Cimmino

    2006-12-01

    Full Text Available Pantoea agglomerans is a common epiphyte of many plant species, and it is associated with Pseudomonas savastanoi pv. savastanoi in young and apparently intact olive knots. Strains of P. agglomerans collected from various olive groves in central Italy were studied for their ability to accumulate plant growth substances in culture. All the strains produced indole-3-aldehyde, indole-3-ethanol and indole-3-acetic acid (IAA, this last compound in amounts (average 8.7 mg l-1 comparable to those produced in vitro by virulent strains of P. savastanoi. None of the olive strains produced cytokinins. It is suggested that the IAA produced by P. agglomerans may increase the size of the knots caused on olive by P. savastanoi.

  8. Metal Reduction and Iron Biomineralization by a Psychrotolerant Fe(III)-Reducing Bacterium, Shewanella sp. Strain PV-4

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Yul; Gao, Haichun; Vali, Hojatollah; Kennedy, David W.; Yang, Zamin; Gao, Weimin; Dohnalkova, Alice; Stapleton, Raymond D.; Moon, Ji-Won; Phelps, T. J.; Fredrickson, Jim K.; Zhou, Jizhong

    2006-05-01

    A marine psychrotolerant, dissimilatory Fe(III)-reducing bacterium, Shewanella sp. strain PV-4, from the microbial mat at a hydrothermal vent of Loihi Seamount in the Pacific Ocean has been further characterized, with emphases on metal reduction and iron biomineralization. The strain is able to reduce metals such as Fe(III), Co(III), Cr(VI), Mn(IV), and U(VI) as electron acceptors while using lactate, formate, pyruvate, or hydrogen as an electron donor. Growth during iron reduction occurred over the pH range of 7.0 to 8.9, a sodium chloride range of 0.05 to 5%, and a temperature range of 0 to 37°C, with an optimum growth temperature of 18°C. Unlike mesophilic dissimilatory Fe(III)-reducing bacteria, which produce mostly superparamagnetic magnetite (<35 nm), this psychrotolerant bacterium produces well-formed single-domain magnetite (>35 nm) at temperatures from 18 to 37°C. The genome size of this strain is about 4.5 Mb. Strain PV-4 is sensitive to a variety of commonly used antibiotics except ampicillin and can acquire exogenous DNA (plasmid pCM157) through conjugation.

  9. Metal Reduction and Iron Biomineralization by a Psychrotolerant Fe(III)-Reducing Bacterium, Shewanella sp. Strain PV-4

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Yul; Gao, Haichun; Vali, Hojatollah; Kennedy, David W.; Yang, Zamin; Gao, Weimin; Dohnalkova, Alice; Stapleton, Raymond D.; Moon, Ji-Won; Phelps, Tommy J.; Fredrickson, Jim K.; Zhou, Jizhong

    2006-09-01

    A marine psychrotolerant, dissimilatory Fe(III)-reducing bacterium, Shewanella sp. strain PV-4, from the microbial mat at a hydrothermal vent of Loihi Seamount in the Pacific Ocean has been further characterized, with emphases on metal reduction and iron biomineralization. The strain is able to reduce metals such as Fe(III), Co(III), Cr(VI), Mn(IV), and U(VI) as electron acceptors while using lactate, formate, pyruvate, or hydrogen as an electron donor. Growth during iron reduction occurred over the pH range of 7.0 to 8.9, a sodium chloride range of 0.05 to 5%, and a temperature range of 0 to 37 C, with an optimum growth temperature of 18 C. Unlike mesophilic dissimilatory Fe(III)-reducing bacteria, which produce mostly superparamagnetic magnetite (<35 nm), this psychrotolerant bacterium produces well-formed single-domain magnetite (>35 nm) at temperatures from 18 to 37 C. The genome size of this strain is about 4.5 Mb. Strain PV-4 is sensitive to a variety of commonly used antibiotics except ampicillin and can acquire exogenous DNA (plasmid pCM157) through conjugation.

  10. Characterization of bacteriophages Cp1 and Cp2, the strain-typing agents for Xanthomonas axonopodis pv. citri.

    Science.gov (United States)

    Ahmad, Abdelmonim Ali; Ogawa, Megumi; Kawasaki, Takeru; Fujie, Makoto; Yamada, Takashi

    2014-01-01

    The strains of Xanthomonas axonopodis pv. citri, the causative agent of citrus canker, are historically classified based on bacteriophage (phage) sensitivity. Nearly all X. axonopodis pv. citri strains isolated from different regions in Japan are lysed by either phage Cp1 or Cp2; Cp1-sensitive (Cp1(s)) strains have been observed to be resistant to Cp2 (Cp2(r)) and vice versa. In this study, genomic and molecular characterization was performed for the typing agents Cp1 and Cp2. Morphologically, Cp1 belongs to the Siphoviridae. Genomic analysis revealed that its genome comprises 43,870-bp double-stranded DNA (dsDNA), with 10-bp 3'-extruding cohesive ends, and contains 48 open reading frames. The genomic organization was similar to that of Xanthomonas phage phiL7, but it lacked a group I intron in the DNA polymerase gene. Cp2 resembles morphologically Escherichia coli T7-like phages of Podoviridae. The 42,963-bp linear dsDNA genome of Cp2 contained terminal repeats. The Cp2 genomic sequence has 40 open reading frames, many of which did not show detectable homologs in the current databases. By proteomic analysis, a gene cluster encoding structural proteins corresponding to the class III module of T7-like phages was identified on the Cp2 genome. Therefore, Cp1 and Cp2 were found to belong to completely different virus groups. In addition, we found that Cp1 and Cp2 use different molecules on the host cell surface as phage receptors and that host selection of X. axonopodis pv. citri strains by Cp1 and Cp2 is not determined at the initial stage by binding to receptors.

  11. Molecular and pathogenic characterization of new Xanthomonas oryzae pv. oryzae strains from the coastline region of Fangchenggang city in China.

    Science.gov (United States)

    Yang, Shu-Qing; Liu, Shu-Yan; Zhao, Shuai; Yu, Yan-Hua; Li, Rong-Bai; Duan, Cheng-Jie; Tang, Ji-Liang; Feng, Jia-Xun

    2013-04-01

    Virulence assays and DNA polymorphism analyses were used to characterize 33 Xanthomonas oryzae pv. oryzae (Xoo) strains collected from the coastline region of Fangchenggang city in China. Two new pathogenic races (FXP1 and FXP2), were determined by leaf-clipping inoculation of 12 near-isogenic International Rice-Bacterial Blight (IRBB) rice lines, each containing a single resistance gene. Race FXP1 consisted of twenty-eight strains that were incompatible on IRBB5 and IRBB7, while race FXP2 included five strains that were incompatible on IRBB5 and IRBB7 and moderately virulent on IRBB8 containing the xa8 gene. Restriction fragment length polymorphism (RFLP) analysis revealed that each probe of avrXa10 and IS1112 resolved two haplotypes. In a dendrogram generated from the combined RFLP data, the 33 Xoo strains were resolved into two clusters. There was a weak correlation (r = 0.53) between race and haplotype. All of the rice cultivars planted in the coastline region of Fangchenggang city were susceptible to the representative Xoo strains tested above. However, we found that four rice cultivars used as breeding materials in the laboratory could fully resist infection by the Xoo strains, suggesting that the isolated Xoo strains could be used to detect resistant rice cultivars suitable for planting in the local rice field.

  12. Development of Specific Markers for Identification of Biovars 1 and 2 Strains of Pseudomonas syringae pv. actinidiae

    Directory of Open Access Journals (Sweden)

    Young Sun Lee

    2016-04-01

    Full Text Available Pseudomonas syringae pv. actinidiae, the causal agent of canker in kiwifruit, can be divided into three biovars (biovars 1, 2, and 3. Strains belonging to biovar 1 produce phaseolotoxin and were isolated in Japan and Italy before 2008. Strains of biovar 2 produce coronatine instead of phaseolotoxin and have been isolated only in Korea. Strains belonging to biovar 3 produce neither phaseolotoxin nor coronatine and are responsible for the global outbreak of bacterial canker of kiwifruit in recent years. The biovar 3-specific primer set was developed in a previous work. In this study, two sets of PCR primers specific to strains of biovars 1 and 2, respectively, were developed based on random amplified polymorphic DNA analyses. Primers PsaJ-F and PsaJ-R produced a 481-bp region with genomic DNA of biovar 1 strains, whereas primers PsaK-F and PsaK-R amplified a 413-bp region present only in the genome of biovar 2 strains.

  13. 'Candidatus Phytoplasma pruni', a novel taxon associated with X-disease of stone fruits, Prunus spp.: multilocus characterization based on 16S rRNA, secY, and ribosomal protein genes.

    Science.gov (United States)

    Davis, Robert E; Zhao, Yan; Dally, Ellen L; Lee, Ing-Ming; Jomantiene, Rasa; Douglas, Sharon M

    2013-02-01

    X-disease is one of the most serious diseases known in peach (Prunus persica). Based on RFLP analysis of 16S rRNA gene sequences, peach X-disease phytoplasma strains from eastern and western United States and eastern Canada were classified in 16S rRNA gene RFLP group 16SrIII, subgroup A. Phylogenetic analyses of 16S rRNA gene sequences revealed that the X-disease phytoplasma strains formed a distinct subclade within the phytoplasma clade, supporting the hypothesis that they represented a lineage distinct from those of previously described 'Candidatus Phytoplasma' species. Nucleotide sequence alignments revealed that all studied X-disease phytoplasma strains shared less than 97.5 % 16S rRNA gene sequence similarity with previously described 'Candidatus Phytoplasma' species. Based on unique properties of the DNA, we propose recognition of X-disease phytoplasma strain PX11CT1(R) as representative of a novel taxon, 'Candidatus Phytoplasma pruni'. Results from nucleotide and phylogenetic analyses of secY and ribosomal protein (rp) gene sequences provided additional molecular markers of the 'Ca. Phytoplasma pruni' lineage. We propose that the term 'Ca. Phytoplasma pruni' be applied to phytoplasma strains whose 16S rRNA gene sequences contain the oligonucleotide sequences of unique regions that are designated in the formally published description of the taxon. Such strains include X-disease phytoplasma and--within the tolerance of a single base difference in one unique sequence--peach rosette, peach red suture, and little peach phytoplasmas. Although not employed for taxon delineation in this work, we further propose that secY, rp, and other genetic loci from the reference strain of a taxon, and where possible oligonucleotide sequences of unique regions of those genes that distinguish taxa within a given 16Sr group, be incorporated in emended descriptions and as part of future descriptions of 'Candidatus Phytoplasma' taxa.

  14. Resistance inducers modulate Pseudomonas syringae pv. tomato strain DC3000 response in tomato plants.

    Directory of Open Access Journals (Sweden)

    Loredana Scalschi

    Full Text Available The efficacy of hexanoic acid (Hx as an inducer of resistance in tomato plants against Pseudomonas syringae pv. tomato DC3000 was previously demonstrated, and the plant response was characterized. Because little is known about the reaction of the pathogen to this effect, the goal of the present work was to determine whether the changes in the plant defence system affect the pathogen behaviour. This work provides the first demonstration of the response of the pathogen to the changes observed in plants after Hx application in terms of not only the population size but also the transcriptional levels of genes involved in quorum sensing establishment and pathogenesis. Therefore, it is possible that Hx treatment attenuates the virulence and survival of bacteria by preventing or diminishing the appearance of symptoms and controlling the growth of the bacteria in the mesophyll. It is interesting to note that the gene transcriptional changes in the bacteria from the treated plants occur at the same time as the changes in the plants. Hx is able to alter bacteria pathogenesis and survival only when it is applied as a resistance inducer because the changes that it promotes in plants affect the bacteria.

  15. Resistance Inducers Modulate Pseudomonas syringae pv. Tomato Strain DC3000 Response in Tomato Plants

    Science.gov (United States)

    Scalschi, Loredana; Camañes, Gemma; Llorens, Eugenio; Fernández-Crespo, Emma; López, María M.; García-Agustín, Pilar; Vicedo, Begonya

    2014-01-01

    The efficacy of hexanoic acid (Hx) as an inducer of resistance in tomato plants against Pseudomonas syringae pv. tomato DC3000 was previously demonstrated, and the plant response was characterized. Because little is known about the reaction of the pathogen to this effect, the goal of the present work was to determine whether the changes in the plant defence system affect the pathogen behaviour. This work provides the first demonstration of the response of the pathogen to the changes observed in plants after Hx application in terms of not only the population size but also the transcriptional levels of genes involved in quorum sensing establishment and pathogenesis. Therefore, it is possible that Hx treatment attenuates the virulence and survival of bacteria by preventing or diminishing the appearance of symptoms and controlling the growth of the bacteria in the mesophyll. It is interesting to note that the gene transcriptional changes in the bacteria from the treated plants occur at the same time as the changes in the plants. Hx is able to alter bacteria pathogenesis and survival only when it is applied as a resistance inducer because the changes that it promotes in plants affect the bacteria. PMID:25244125

  16. Immune Status, Strain Background, and Anatomic Site of Inoculation Affect Mouse Papillomavirus (MmuPV1) Induction of Exophytic Papillomas or Endophytic Trichoblastomas

    Science.gov (United States)

    Sundberg, John P.; Proctor, Mary; Ingle, Arvind; Silva, Kathleen A.; Dadras, Soheil S.; Jenson, A. Bennett; Ghim, Shin-je

    2014-01-01

    Papillomaviruses (PVs) induce papillomas, premalignant lesions, and carcinomas in a wide variety of species. PVs are classified first based on their host and tissue tropism and then their genomic diversities. A laboratory mouse papillomavirus, MmuPV1 (formerly MusPV), was horizontally transmitted within an inbred colony of NMRI-Foxn1nu/Foxn1nu (nude; T cell deficient) mice of an unknown period of time. A ground-up, filtered papilloma inoculum was not capable of infecting C57BL/6J wild-type mice; however, immunocompetent, alopecic, S/RV/Cri-ba/ba (bare) mice developed small papillomas at injection sites that regressed. NMRI-Foxn1nu and B6.Cg-Foxn1nu, but not NU/J-Foxn1nu, mice were susceptible to MmuPV1 infection. B6 congenic strains, but not other congenic strains carrying the same allelic mutations, lacking B- and T-cells, but not B-cells alone, were susceptible to infection, indicating that mouse strain and T-cell deficiency are critical to tumor formation. Lesions initially observed were exophytic papillomas around the muzzle, exophytic papillomas on the tail, and condylomas of the vaginal lining which could be induced by separate scarification or simultaneous scarification of MmuPV1 at all four sites. On the dorsal skin, locally invasive, poorly differentiated tumors developed with features similar to human trichoblastomas. Transcriptome analysis revealed significant differences between the normal skin in these anatomic sites and in papillomas versus trichoblastomas. The primarily dysregulated genes involved molecular pathways associated with cancer, cellular development, cellular growth and proliferation, cell morphology, and connective tissue development and function. Although trichoepitheliomas are benign, aggressive tumors, few of the genes commonly associated with basal cell carcinoma or squamous cells carcinoma were highly dysregulated. PMID:25474466

  17. Comparative genomics of 43 strains of Xanthomonas citri pv. citri reveals the evolutionary events giving rise to pathotypes with different host ranges.

    Science.gov (United States)

    Gordon, Jonathan L; Lefeuvre, Pierre; Escalon, Aline; Barbe, Valérie; Cruveiller, Stéphane; Gagnevin, Lionel; Pruvost, Olivier

    2015-12-23

    The identification of factors involved in the host range definition and evolution is a pivotal challenge in the goal to predict and prevent the emergence of plant bacterial disease. To trace the evolution and find molecular differences between three pathotypes of Xanthomonas citri pv. citri that may explain their distinctive host ranges, 42 strains of X. citri pv. citri and one outgroup strain, Xanthomonas citri pv. bilvae were sequenced and compared. The strains from each pathotype form monophyletic clades, with a short branch shared by the A(w) and A pathotypes. Pathotype-specific recombination was detected in seven regions of the alignment. Using Ancestral Character Estimation, 426 SNPs were mapped to the four branches at the base of the A, A*, A(w) and A/A(w) clades. Several genes containing pathotype-specific nonsynonymous mutations have functions related to pathogenicity. The A pathotype is enriched for SNP-containing genes involved in defense mechanisms, while A* is significantly depleted for genes that are involved in transcription. The pathotypes differ by four gene islands that largely coincide with regions of recombination and include genes with a role in virulence. Both A* and A(w) are missing genes involved in defense mechanisms. In contrast to a recent study, we find that there are an extremely small number of pathotype-specific gene presences and absences. The three pathotypes of X. citri pv. citri that differ in their host ranges largely show genomic differences related to recombination, horizontal gene transfer and single nucleotide polymorphism. We detail the phylogenetic relationship of the pathotypes and provide a set of candidate genes involved in pathotype-specific evolutionary events that could explain to the differences in host range and pathogenicity between them.

  18. Cloning of a two-component signal transduction system of Xanthomonas campestris pv. phaseoli var. fuscans strain BXPF65

    DEFF Research Database (Denmark)

    Chan, JWYF; Maynard, Scott; Goodwin, PH

    1998-01-01

    A putative two-component signal transduction system was amplified and cloned from the plant pathogenic bacterium Xanthomonas campestris pv. phaseoli var. fuscans isolate BXPF65. The 620 bp amplified fragment was sequenced and analyzed with the BLAST Enhanced Alignment Utility (BEAUTY). BEAUTY ana...

  19. In vitro study of biological activity of four strains of Burkholderia gladioli pv. agaricicola and identification of their bioactive metabolites using

    Directory of Open Access Journals (Sweden)

    Hazem S. Elshafie

    2017-02-01

    Full Text Available This research was carried out to study in vitro antibacterial activity of 4 strains of Burkholderia gladioli pv. agaricicola (Bga against G+ve Bacillus megaterium and G−ve Escherichia coli, haemolytic activity against the cell membrane of erythrocytes, the production of extracellular hydrolytic enzymes and finally, the pathogenicity against Agaricus bisporus flesh blocks. Chemical structure of bioactive substances of the most bioactive strain (ICMP 11096 was established using gas chromatography–mass spectrometry (GC–MS. All the studied Bga strains inhibited the growth of the two tested bacteria although some growing substrates negatively influenced the antimicrobial substance production. The same Bga strains showed highly haemolytic activity and were able to produce 3 hydrolytic enzymes, i.e. chitinase, glucanase and protease. In pathogenicity assays, the considered Bga strains resulted virulent for A. bisporus. The GC–MS for compounds from Bga ICMP 11096 were compatible with the structure of two bioactive fatty acids identified as methyl stearate and ethanol 2-butoxy phosphate with mass spectrum m/e 298 and 398, respectively.

  20. RNAseq analysis of cassava reveals similar plant responses upon infection with pathogenic and non-pathogenic strains of Xanthomonas axonopodis pv. manihotis.

    Science.gov (United States)

    Muñoz-Bodnar, Alejandra; Perez-Quintero, Alvaro L; Gomez-Cano, Fabio; Gil, Juliana; Michelmore, Richard; Bernal, Adriana; Szurek, Boris; Lopez, Camilo

    2014-11-01

    An RNAseq-based analysis of the cassava plants inoculated with Xam allowed the identification of transcriptional upregulation of genes involved in jasmonate metabolism, phenylpropanoid biosynthesis and putative targets for a TALE. Cassava bacterial blight, a disease caused by the gram-negative bacterium Xanthomonas axonopodis pv. manihotis (Xam), is a major limitation to cassava production worldwide and especially in developing countries. The molecular mechanisms underlying cassava susceptibility to Xam are currently unknown. To identify host genes and pathways leading to plant susceptibility, we analyzed the transcriptomic responses occurring in cassava plants challenged with either the non-pathogenic Xam strain ORST4, or strain ORST4(TALE1 Xam ) which is pathogenic due to the major virulence transcription activator like effector TALE1 Xam . Both strains triggered similar responses, i.e., induction of genes related to photosynthesis and phenylpropanoid biosynthesis, and repression of genes related to jasmonic acid signaling. Finally, to search for TALE1 Xam virulence targets, we scanned the list of cassava genes induced upon inoculation of ORST4(TALE1 Xam ) for candidates harboring a predicted TALE1 Xam effector binding element in their promoter. Among the six genes identified as potential candidate targets of TALE1 Xam a gene coding for a heat shock transcription factor stands out as the best candidate based on their induction in presence of TALE1 Xam and contain a sequence putatively recognized by TALE1 Xam .

  1. Comparative genomics of multiple strains of Pseudomonas cannabina pv. alisalensis, a potential model pathogen of both monocots and dicots.

    Directory of Open Access Journals (Sweden)

    Panagiotis F Sarris

    Full Text Available Comparative genomics of closely related pathogens that differ in host range can provide insights into mechanisms of host-pathogen interactions and host adaptation. Furthermore, sequencing of multiple strains with the same host range reveals information concerning pathogen diversity and the molecular basis of virulence. Here we present a comparative analysis of draft genome sequences for four strains of Pseudomonas cannabina pathovar alisalensis (Pcal, which is pathogenic on a range of monocotyledonous and dicotyledonous plants. These draft genome sequences provide a foundation for understanding host range evolution across the monocot-dicot divide. Like other phytopathogenic pseudomonads, Pcal strains harboured a hrp/hrc gene cluster that codes for a type III secretion system. Phylogenetic analysis based on the hrp/hrc cluster genes/proteins, suggests localized recombination and functional divergence within the hrp/hrc cluster. Despite significant conservation of overall genetic content across Pcal genomes, comparison of type III effector repertoires reinforced previous molecular data suggesting the existence of two distinct lineages within this pathovar. Furthermore, all Pcal strains analyzed harbored two distinct genomic islands predicted to code for type VI secretion systems (T6SSs. While one of these systems was orthologous to known P. syringae T6SSs, the other more closely resembled a T6SS found within P. aeruginosa. In summary, our study provides a foundation to unravel Pcal adaptation to both monocot and dicot hosts and provides genetic insights into the mechanisms underlying pathogenicity.

  2. Parasitoids (Hymenoptera: Braconidae, Aphidiinae of the mealy plum aphid Hyalopterus pruni (Geoffr. on common reed (Phragmites australis in different types of habitat in Poland

    Directory of Open Access Journals (Sweden)

    Barczak T.

    2013-01-01

    Full Text Available The aim of the present work was to determine the parasitoid guild of the mealy plum aphid Hyalopterus pruni on common reed (Phragmites australis in different types of habitats in central Poland. The investigations were carried out in selected areas of the Salted Kujawy Region (central-northern Poland. To compare the parasitoid guilds of H. pruni from common reed in different types of habitats, species composition, number, domination structure and the percentage of parasitization (effectiveness were evaluated. The primary parasitoid guild of H. pruni on common reed in central Poland comprises three aphidiine braconids, mainly Praon volucre and P. abjectum. The number of the primary parasitoid species and their effectiveness in the aphid colonies were very low. Hence, common reed did not seem to be a good reservoir of the H. pruni parasitoids, but it may play a role as a place of dispersion of these insects, beneficial to orchards. A very low number of the hyperparasitoids were observed in the aphid colonies.

  3. The sex pheromones of mealy plum (Hyalopterus pruni) and leaf-curl plum (Brachycaudus helichrysi) aphids: identification and field trapping of male and gynoparous aphids in prune orchards.

    Science.gov (United States)

    Symmes, Emily J; Dewhirst, Sarah Y; Birkett, Michael A; Campbell, Colin A M; Chamberlain, Keith; Pickett, John A; Zalom, Frank G

    2012-05-01

    Mealy plum, Hyalopterus pruni, and leaf-curl plum, Brachycaudus helichrysi, aphids are the primary arthropod pests in orchards that produce dried plums (i.e., prunes). The sexual stage of their respective lifecycles occurs on prune trees in the fall, during which time males respond to sex pheromones produced by oviparous females. Air-entrainment collections confirmed that oviparous H. pruni and B. helichrysi emitted combinations of (4aS, 7S, 7aR)-nepetalactone and (1R, 4aS, 7S, 7aR)-nepetalactol. The responses of H. pruni and B. helichrysi to these compounds in ratios of 1:0, 0:1, 1:1, 2.6:1, 3.4:1, 5:1, 7:1, and 0:0 (no-pheromone control) using water traps were determined in field experiments conducted in prune orchards during the fall. The greatest number of male H. pruni was caught in traps releasing a 1:1 ratio of (4aS, 7S, 7aR)-nepetalactone and (1R, 4aS, 7S, 7aR)-nepetalactol, while male B. helichrysi were caught in similar numbers in traps releasing any of the two-component ratios tested. There was no evidence that any of the pheromone treatments influenced trap catches of gynoparae of either species. Results suggest that addition of sex pheromone lures increases trap catches of male H. pruni and B. helichrysi, and that this approach may improve monitoring and management of these pests in prune orchards. Knowledge gained from this study contributes to the understanding of the ecology of insect pests in prune orchards.

  4. RNAseq analysis of cassava reveals similar plant responses upon infection with pathogenic and non-pathogenic strains of Xanthomonas axonopodis pv. manihotis

    OpenAIRE

    Munoz-Bodnar, A.; Perez-Quintero, A.; Gomez-Cano, F.; Gil, J.; Michelmore, R.; Bernal, A.; Szurek, Boris; Lopez, C.

    2014-01-01

    An RNAseq-based analysis of the cassava plants inoculated with Xam allowed the identification of transcriptional upregulation of genes involved in jasmonate metabolism, phenylpropanoid biosynthesis and putative targets for a TALE. Cassava bacterial blight, a disease caused by the gram-negative bacterium Xanthomonas axonopodis pv. manihotis (Xam), is a major limitation to cassava production worldwide and especially in developing countries. The molecular mechanisms underlying cassava susceptibi...

  5. Autonomous cascaded PV system

    OpenAIRE

    2011-01-01

    This paper proposes multi-level PV system; three PV generators each coupled to a buck cell. Each PV-generator-buckconverter channel is controlled such that maximum power is captured independently under different irradiation and temperature levels. The system operation under normal/abnormal conditions is investigated by thoroughly mathematical and simulation work. Peer Reviewed

  6. Analysis of the small RNA P16/RgsA in the plant pathogen Pseudomonas syringae pv. tomato strain DC3000

    OpenAIRE

    Park, So Hae; Butcher, Bronwyn G.; Anderson, Zoe; Pellegrini, Nola; Bao, Zhongmeng; D’Amico, Katherine; Melanie J Filiatrault

    2013-01-01

    Bacteria contain small non-coding RNAs (ncRNAs) that are responsible for altering transcription, translation or mRNA stability. ncRNAs are important because they regulate virulence factors and susceptibility to various stresses. Here, the regulation of a recently described ncRNA of Pseudomonas syringae pv. tomato DC3000, P16, was investigated. We determined that RpoS regulates the expression of P16. We found that deletion of P16 results in increased sensitivity to hydrogen peroxide compared t...

  7. Fire resistant PV shingle assembly

    Science.gov (United States)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  8. PsasM2I, a type II restriction-modification system in Pseudomonas savastanoi pv. savastanoi: differential distribution of carrier strains in the environment and the evolutionary history of homologous RM systems in the Pseudomonas syringae complex.

    Science.gov (United States)

    Cinelli, Tamara; Moscetti, Ilaria; Marchi, Guido

    2014-11-01

    A type II restriction-modification system was found in a native plasmid of Pseudomonas savastanoi pv. savastanoi MLLI2. Functional analysis of the methyltransferase showed that the enzyme acts by protecting the DNA sequence CTGCAG from cleavage. Restriction endonuclease expression in recombinant Escherichia coli cells resulted in mutations in the REase sequence or transposition of insertion sequence 1A in the coding sequence, preventing lethal gene expression. Population screening detected homologous RM systems in other P. savastanoi strains and in the Pseudomonas syringae complex. An epidemiological survey carried out by sampling olive and oleander knots in two Italian regions showed an uneven diffusion of carrier strains, whose presence could be related to a selective advantage in maintaining the RM system in particular environments or subpopulations. Moreover, carrier strains can coexist in the same orchards, plants, and knot tissues with non-carriers, revealing unexpected genetic variability on a very small spatial scale. Phylogenetic analysis of the RM system and housekeeping gene sequences in the P. syringae complex demonstrated the ancient acquisition of the RM systems. However, the evolutionary history of the gene complex also showed the involvement of horizontal gene transfer between related strains and recombination events.

  9. ALTERNATIVES FOR PRESERVATION OF BIOACTIVE COMPOUNDS IN BLUEBERRY PULP: HEAT TREATMENT ASSOCIATED WITH THE ADDITION OF XANTHAN PRUNI

    Directory of Open Access Journals (Sweden)

    JÚLIA BORIN FIORAVANTE

    Full Text Available ABSTRACT In this study, to increase the preservation of phenolic bioactive compounds and antioxidant activity in blueberry pulp, heat treatment associated with addition of xanthan gum was used. A commercial mixture of blueberries (Powerblue, Climax and Bluegen cultivars was added with 0.08% (w/w citric acid and subjected to heat treatment by direct heating until 90 °C in conventional open pan (OP and by direct application of steam (AS; both with and without the addition of xanthan pruni (OPX and ASX, followed by pulping. Samples of only frozed fruits were considered as control. The five treatments remained under freezing and were evaluated until 90 days of storage for antioxidant activity, phenols, flavonoids and total monomeric anthocyanins. The results show that, with the exception of phenolics, heat treatment with direct steam application and xanthan addition favored bioactive compounds preservation during storage. These factors influenced positively on the anthocyanins stability during frozen storage for 90 days. The xanthan addition favored antioxidant activity preservation; preservation for antioxidant activity by ABTS and DPPH, in all heat treatments, was observed.

  10. Pseudomonas cannabina pv. cannabina pv. nov., and Pseudomonas cannabina pv. alisalensis (Cintas Koike and Bull, 2000) comb. nov., are members of the emended species Pseudomonas cannabina (ex Sutic & Dowson 1959) Gardan, Shafik, Belouin, Brosch, Grimont & Grimont 1999.

    Science.gov (United States)

    Bull, Carolee T; Manceau, Charles; Lydon, John; Kong, Hyesuk; Vinatzer, Boris A; Fischer-Le Saux, Marion

    2010-04-01

    Sequence similarity in the 16S rDNA gene confirmed that crucifer pathogen Pseudomonas syringae pv. alisalensis belongs to P. syringae sensu lato. In reciprocal DNA/DNA hybridization experiments, DNA relatedness was high (69-100%) between P. syringae pv. alisalensis strains and the type strain of P. cannabina (genomospecies 9). In contrast, DNA relatedness was low (below 48%) between P. syringae pv. alisalensis and reference strains from the remaining genomospecies of P. syringae including the type strain of P. syringae and reference strain of genomospecies 3 (P. syringae pv. tomato) although the well-known crucifer pathogen, P. syringae pv. maculicola, also belongs to genomospecies 3. Additional evidence that P. syringae pv. alisalensis belongs to P. cannabina was sequence similarity in five gene fragments used in multilocus sequence typing, as well as similar rep-PCR patterns when using the BOX-A1R primers. The description of P. cannabina has been emended to include P. syringae pv. alisalensis. Host range testing demonstrated that P. syringae pv. alisalensis strains, originally isolated from broccoli, broccoli raab or arugula, were not pathogenic on Cannabis sativa (family Cannabinaceae). Additionally, P. cannabina strains, originally isolated from the C. sativa were not pathogenic on broccoli raab or oat while P. syringae pv. alisalensis strains were pathogenic on these hosts. Distinct host ranges for these two groups indicate that P. cannabina emend. consists of at least two distinct pathovars, P. cannabina pv. cannabina pv. nov., and P. cannabina pv. alisalensis comb. nov. Pseudomonas syringae pv. maculicola strain CFBP 1637 is a member of P. cannabina.

  11. Caracterização de isolados de Xanthomonas campestris pv campestris de sistemas de produção orgânico e reação de brássicas à podridão-negra Characterization of strains of Xanthomonas campestris pv campestris from organic farming systems and reaction of brassicas to black rot

    Directory of Open Access Journals (Sweden)

    Liliana Andréa dos Santos

    2008-12-01

    Full Text Available Noventa isolados de Xanthomonas campestris pv. campestris (Xcc de brássicas oriundas de sistemas de produção orgânico das Zonas da Mata e Agreste de Pernambuco foram caracterizados com base na sensibilidade a antibióticos e sulfato de cobre e atividade de esterase. A maioria apresentou alta sensibilidade à tetraciclina (76,6%, eritromicina (63,3% e estreptomicina (63,3%, resistência à amoxicilina (70%, gentamicina (40,0% e norfloxacin (45,5% e média sensibilidade (44,4% ou resistência (44,4% à neomicina. Cinqüenta e cinco isolados de Xcc foram resistentes ao sulfato de cobre na concentração de 50 mg/mL e todos foram sensíveis ao produto na concentração de 200 mg/mL. Atividade de esterase foi apresentada por 92,22% dos isolados. A análise Euclidiana por ligação simples evidenciou variabilidade entre os isolados separando-os em sete grupos de similaridade. Foi estudada também a reação de 14 cultivares de brássicas à podridão-negra, utilizando o isolado "B21" de Xcc. As cultivares diferiram significativamente entre si em relação ao período de incubação, incidência e severidade final da doença. Os maiores valores de severidade final da doença foram verificados em brócolos "Ramoso", couve-flor "Bola de Neve" e "Piracicaba de Verão", e repolho "Chato de Quintal". Os híbridos de couve-chinesa "AF 70", "AF 72", "AF 69" e "AF 66" mostraram-se altamente resistentes à doença, enquanto que brócolos "Ramoso" e "Precoce Piracicaba", couve-flor "Piracicaba de Verão" e "Híbrido Cindy" e repolho "60 Dias" foram medianamente resistentes.Ninety strains of Xanthomonas campestris pv. campestris (Xcc from brassicas grown under organic farming systems in the "Mata" and "Agreste" regions of Pernambuco, Brazil, were characterized based upon sensitivity to antibiotics and copper sulfate, and esterase activity. Most of the strains showed high sensitivity to tetracycline (76.6%, erythromycin (63.3% and streptomycin (63

  12. Evaluation of physical and chemical characteristics of xanthan gums

    Directory of Open Access Journals (Sweden)

    Claire Tondo Vendruscolo

    2007-03-01

    Full Text Available This work aimed at evaluating the physical and chemical characteristics of the xanthan produced by Xanthomonas arboricola pv pruni strain 115, and at comparing it with two xanthans obtained from commercial sources – Kelzan e Roeper. The analyzed xanthans showed specified patterns mentioned in the literature, except for low pyruvic acid content in the xanthan produced by strain 115, low monovalent salt content in the Roeper sample and high divalent salt content in both commercial samples. The low pyruvic acid content in the xanthan produced by X. arboricola pv pruni 115 did not affect the aqueous solution viscosity. Thus, the xanthan produced by strain 115 show physical and chemical characteristics that allow its use by the petroleum industry, as well as, in food, pharmaceutical and cosmetics products. Xanthomonas arboricola pv pruni. Xanthan. Physical and chemical characteristics.

  13. First report of the crucifer pathogen Pseudomonas cannabina pv. alisalensis causing bacterial blight on radish (Raphanus sativus) in Germany

    Science.gov (United States)

    Pseudomonas cannabina pv. alisalensis is a severe pathogen of crucifers across the U.S. We compared a strain isolated from diseased radish (Raphanus sativus) in Germany to pathotypes and additional strains of P. cannabina pv. alisalensis and P. syringae pv. maculicola. We demonstrated that the patho...

  14. Antagonism of Bacillus spp. against Xanthomonas campestris pv. campestris

    OpenAIRE

    Leila Monteiro; Rosa de Lima Ramos Mariano; Ana Maria Souto-Maior

    2005-01-01

    The antagonism of eight Bacillus isolates was investigated against nine strains of Xanthomonas campestris pv. campestris (causal agent of crucifers black rot) to assess the role of lipopeptides in this process. Antimicrobial and hemolytic (surfactant) activity tests were performed in vitro using agar diffusion methods. Antibiosis and hemolysis were positive for four Bacillus isolates against all X. campestris pv. campestris strains. The correlation observed between antimicrobial and hemolytic...

  15. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  16. Grid integrated distributed PV (GridPV).

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2013-08-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functions are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in the OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function in the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  17. PV-WEB: internet-based PV information tool

    Energy Technology Data Exchange (ETDEWEB)

    Cowley, P.

    2003-07-01

    This report gives details of a project to create a web-based information system on photovoltaic (PV) systems for the British PV Association (PV-UK) for use by decision makers in government, the utilities, and the housing and construction sectors. The project, which aims to provide an easily accessible tool for UK companies, promote PV technology, increase competitiveness, and identify market opportunities, is described. The design of the web site and its implementation and the evolution are discussed, along with the maintenance of the site by PV-UK and the opportunities offered to PV-UK Members.

  18. PV power forecast using a nonparametric PV model

    OpenAIRE

    Almeida, Marcelo Pinho; Perpiñan Lamigueiro, Oscar; Narvarte Fernández, Luis

    2015-01-01

    Forecasting the AC power output of a PV plant accurately is important both for plant owners and electric system operators. Two main categories of PV modeling are available: the parametric and the nonparametric. In this paper, a methodology using a nonparametric PV model is proposed, using as inputs several forecasts of meteorological variables from a Numerical Weather Forecast model, and actual AC power measurements of PV plants. The methodology was built upon the R environment and uses Quant...

  19. Draft genome sequences of pseudomonas syringae pv. syringae ALF3 isolated from alfalfa

    Science.gov (United States)

    We report the annotated draft genome of Pseudomonas syringae pv. syringae strain ALF3, isolated in Wyoming, USA. Comparison of this genome sequence with those of closely related strains of P. syringae pv. syringae adapted to other hosts will facilitate research into interactions between this pathoge...

  20. PV investment in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Hueser, Pius [Nova Energy GmbH, (Switzerland)

    2007-06-15

    This presentation is mainly about how the PV market in Europe has been growing, and which elements are going to determine if this market succeed or failed not only in Europe but also in the rest of the world. In the first part of this presentation, it is mentioned how in 2005 the development of some PV technologies triggered the PV market growth without any marketing control. Then, there are explained the aspects that changed such situation out of control, therefore, it emerged the beginning of the consolidation of this market. There are briefly explained those factors that are going to determine if this market succeed or failed in the future. Finally, there are given examples of some the PV investments. [Spanish] Esta presentacion habla principalmente de la manera en como ha crecido el Mercado de sistemas fotovoltaicos en Europa, asi tambien se mencionan los elementos fundamentales que determinaran el exito o fracaso de este mercado, no solamente en Europa sino tambien en el resto del mundo, en un futuro. En la primera parte de esta presentacion, se describe como en el 2005, debido al desarrollo de algunas tecnologias fotovoltaicas se desencadeno el crecimiento desenfrenado del mercado fotovoltaico. Despues, se explican los aspectos que hicieron que dicho crecimiento tomara su curso, teniendo como resultado el inicio de un mercado mas consolidado. Se explican brevemente los factores que determinaran si este mercado encuentra el exito o el fracaso en un futuro. Finalmente, se dan ejemplos de algunas adquisiciones fotovoltaicas.

  1. Testing for PV Reliability (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Bansal, S.

    2014-09-01

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  2. Firefighter Safety for PV Systems

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Spataru, Sergiu

    2015-01-01

    An important and highly discussed safety issue for photovoltaic (PV) systems is that as long as the PV panels are illuminated, a high voltage is present at the PV string terminals and cables between the string and inverters that is independent of the state of the inverter's dc disconnection switc...

  3. PV potential and potential PV rent in European regions

    DEFF Research Database (Denmark)

    Hansen, Anders Chr.; Thorn, Paul

    2013-01-01

    The paper provides a GIS based model for assessing the potentials of photovoltaic electricity in Europe by NUTS 2 regions. The location specific energy potential per PV-­‐panel area is estimated based on observations of solar irradiation, conversion efficiency, levelised costs and the social value...... of PV-­‐electricity. Combined with the potential density of PV-­‐panel area based on land cover and environental restrictions, the PV energy potential and the potential PV ressource rent is calculated. These calculations enbable the model to estimate the regional patterns at NUTS 2 level...

  4. PV potential and potential PV rent in European regions

    DEFF Research Database (Denmark)

    Hansen, Anders Chr.; Thorn, Paul

    2013-01-01

    The paper provides a GIS based model for assessing the potentials of photovoltaic electricity in Europe by NUTS 2 regions. The location specific energy potential per PV-­‐panel area is estimated based on observations of solar irradiation, conversion efficiency, levelised costs and the social value...... of PV-­‐electricity. Combined with the potential density of PV-­‐panel area based on land cover and environental restrictions, the PV energy potential and the potential PV ressource rent is calculated. These calculations enbable the model to estimate the regional patterns at NUTS 2 level...

  5. Sensitivity to copper in Xanthomonas campestris pv. viticola

    OpenAIRE

    2009-01-01

    ABSTRACT Bacterial canker, caused by Xanthomonas campestris pv. viticola, affects grapevines in the irrigated areas of the São Francisco river valley, in the states of Pernambuco and Bahia. Several practices for disease management have been adopted including copper sprays.This is the only available chemical control method and most frequently used in the areas affected by the disease. The objective of this work was to determine the sensitivity to copper of strains of X. campestris pv. vi...

  6. PV water pumping: NEOS Corporation recent PV water pumping activities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, C.

    1995-11-01

    NEOS Corporation has been very active in PV-powered water pumping, particularly with respect to electric utilities. Most of the recent activity has been through the Photovoltaic Services Network (PSN). The PSN is an independent, not-for-profit organization comprised of all types of electric utilities: rural electric coops, public power districts, investor-owned utilities, and power marketing agencies. The PSN`s mission is to work pro-actively to promote utility involvement in PV through education and training. PV information is distributed by the PSN in three primary forms: (1) consultation with PSN technical service representatives: (2) literature generated by the PSN; and (3) literature published by other organizations. The PSN can also provide assistance to members in developing PV customer service programs. The PSN`s product support activities include consolidation of information on existing packaged PV systems and facilitation of the development of new PV product packages that meet utility-defined specifications for cost performance, and reliability. The PSN`s initial product support efforts will be focused on commercially available packaged PV systems for a variety of off-grid applications. In parallel with this effort, if no products exist that meet the PSN`s functional specifications, the PSN will initiate the second phase of product development support process by encouraging the development of new packaged systems. Through these services and product support activities, the PSN anticipates engaging all segments for the PV industry, thus providing benefits to PV systems suppliers as well as local PV service contractors.This paper describes field testing of pv power systems for water pumping.

  7. Sensorless PV Array Diagnostic Method for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso; Spataru, Sergiu; Mathe, Laszlo

    2011-01-01

    This work proposes a temperature and irradiance sensorless diagnostic method suitable for small residential PV installations, focusing on detection of partial shadows. The method works by detection of failures in crystalline silicone PV arrays by concomitant monitoring of some of their key parame...

  8. Interband cascade (IC) photovoltaic (PV) architecture for PV devices

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.

    2015-10-20

    A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.

  9. Amplified fragment length polymorphism and multilocus sequence analysis-based genotypic relatedness among pathogenic variants of Xanthomonas citri pv. citri and Xanthomonas campestris pv. bilvae.

    Science.gov (United States)

    Bui Thi Ngoc, Lan; Vernière, Christian; Jouen, Emmanuel; Ah-You, Nathalie; Lefeuvre, Pierre; Chiroleu, Frédéric; Gagnevin, Lionel; Pruvost, Olivier

    2010-03-01

    Three pathogenic variants (i.e. pathotypes) have been described within Xanthomonas citri pv. citri, the causal agent of Asiatic citrus canker. Pathotype A strains naturally infect a wide range of Citrus species and members of some related genera. In contrast, pathotypes A* and A(w) have narrow host ranges within the genus Citrus and have been isolated from Mexican lime (Citrus aurantifolia L.) and from Mexican lime and alemow (Citrus macrophylla L.), respectively. We used amplified fragment length polymorphism (AFLP) and multilocus sequence analysis (MLSA) based on four partial housekeeping gene sequences (atpD, dnaK, efp and gyrB ) for the genotypic classification of Xanthomonas citri pv. citri and the poorly characterized citrus pathogen Xanthomonas campestris pv. bilvae. A Mantel test showed that genetic distances derived from AFLP and MLSA were highly correlated. X. campestris pv. bilvae showed a close relatedness to the type strain of X. citri, indicating that this pathovar should be reclassified as X. citri pv. bilvae. All pathotype A* and A(w) strains were most closely related to X. citri pv. citri strains with a wide host range (pathotype A), confirming previous DNA-DNA hybridization data. Pathotype A(w) should be considered a junior synonym of pathotype A* on the basis of pathogenicity tests, AFLP, MLSA and PCR using pathovar-specific primers. Evolutionary genome divergences computed from AFLP data suggested that pathotype A* (including A(w) strains) is a group of strains that shows a wider genetic diversity than pathotype A.

  10. 烟草角斑病菌拮抗细菌筛选及抗菌活性物质研究%Screening of antagonistic bacterial strain against Pseudomonas ;syringae pv. tabaci and studies on antagonistic active substances

    Institute of Scientific and Technical Information of China (English)

    文景芝; 赵黎明; 杨晓敏; 孙剑萍; 刘振平

    2014-01-01

    研究从黑龙江省健康烟草植株及其根际土壤和海南三亚采集的20种杂草中分别分离到287和98个细菌分离物,筛选出对烟草角斑病菌有拮抗活性的菌株22个,其中来自三亚稗草叶片中的一株细菌PA-2的抑菌效果最好,抑菌效果稳定。经形态学、生理生化及分子生物学鉴定, PA-2为铜绿假单胞杆菌(Pseudomonas aeruginosa)。筛选出最佳实验室发酵配方:氮源1%(牛肉膏��蛋白胨=5��3),葡萄糖0.3%, NaCl 0.5%, KNO30.3%;最佳培养条件:发酵温度28℃,培养基pH 7.0~7.5,接种量4%,装液量为250 mL三角瓶中装液50 mL。PA-2优化发酵液的田间防效达69.77%,比农用链霉素防效提高24.47%。采用硫酸铵分级沉淀法分离抑菌活性物质,结果表明,在(NH4)2SO4浓度为30%~90%各浓度梯度下均有抑菌活性物质沉淀,其中60%~70%(不含60%)是抑菌活性物质的最适盐析饱和度。抑菌活性物质具有较强的热稳定性、较好的蛋白酶耐受性、较好的耐碱性、较差的耐酸性,能溶于部分有机溶剂,经乙醇、乙醚、氯仿、乙酸乙酯、正丁醇和丙酮萃取后,该抑菌活性物质抑菌活性下降范围为1.4%~4%。确定该抑菌活性物质为小分子碱性、水溶性脂肽类物质。%In the present study, 287 and 98 bacterial strains were isolated from healthy tobacco plants and their rhizospheric soil samples as wel as 20 kinds of weeds from Hainan Province, in which 22 strains had antibacterial activity against Pseudomonas syingae pv.tabaci. The strain PA-2 that was identified as Pseudomonas aeruginosa by morphological, physiological and biochemical as wel as molecular biology tests was isolated from the leaf of Echinochloa crusgal i in Sanya and had the best inhibiting and stable effect. The optimal fermentation medium components for PA-2 constituted of 1%of nitrogen (beef extract:peptone=5:3), 0.1% of glucose, 0.5% of sodium

  11. Speedometers for PV generators; Drehzahlmesser fuer PV-Generatoren

    Energy Technology Data Exchange (ETDEWEB)

    Fritze, Peter; Weinreich, Bernhard [Solarschmiede GmbH, Muenchen (Germany). Engineering-Abt.

    2011-05-31

    To measure the generator power of an installed PV system, it is not enough to look into the specifications of hte module producers. Fast and independent data can be provided by characteristic curve meters.

  12. PV in a sports arena; PV im Hexenkessel

    Energy Technology Data Exchange (ETDEWEB)

    Hoeche, B.

    2008-05-19

    The German soccer club Werder Bremen is reconstructing its stadium. Apart from higher spectator comfort and a better atmosphere, there will also be PV systems on the roof and external walls of the arena. (orig.)

  13. PSCAD Modules Representing PV Generator

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2013-08-01

    Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

  14. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan; Gotseff, Peter; Baker, Kyri

    2016-05-05

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

  15. Proposal of Xanthomonas translucens pv. pistaciae pv. nov., pathogenic to pistachio (Pistacia vera).

    Science.gov (United States)

    Giblot-Ducray, Danièle; Marefat, Alireza; Gillings, Michael R; Parkinson, Neil M; Bowman, John P; Ophel-Keller, Kathy; Taylor, Cathy; Facelli, Evelina; Scott, Eileen S

    2009-12-01

    Strains of Xanthomonas translucens have caused dieback in the Australian pistachio industry for the last 15 years. Such pathogenicity to a dicotyledonous woody host contrasts with that of other pathovars of X. translucens, which are characterized by their pathogenicity to monocotyledonous plant families. Further investigations, using DNA-DNA hybridization, gyrB gene sequencing and integron screening, were conducted to confirm the taxonomic status of the X. translucens pathogenic to pistachio. DNA-DNA hybridization provided a clear classification, at the species level, of the pistachio pathogen as a X. translucens. In the gyrB-based phylogeny, strains of the pistachio pathogen clustered among the X. translucens pathovars as two distinct lineages. Integron screening revealed that the cassette arrays of strains of the pistachio pathogen were different from those of other Xanthomonas species, and again distinguished two groups. Together with previously reported pathogenicity data, these results confirm that the pistachio pathogen is a new pathovar of X. translucens and allow hypotheses about its origin. The proposed name is Xanthomonas translucens pv. pistaciae pv. nov.

  16. PV system testing and standards

    Science.gov (United States)

    DeBlasio, Richard

    1999-03-01

    The U.S. Department of Energy (DOE) PV Program System Performance and Engineering Project is being conducted by The National Renewable Energy Laboratory (NREL), Sandia National Laboratories (SNL), Southwest Technology Development Institute (SWTDI), and Florida Solar Energy Center (FSEC). It provides PV system, subsystem, and component-level technology-performance characterization testing; test-method development and validation; national and international consensus standards and codes development, test-facility product certification, and laboratory-accreditation program implementation; and information exchange and technical assistance to the PV community. Emphasis is placed on reducing technical and infrastructural barriers to system acceptance, reducing life-cycle cost of systems, providing systems-engineering best practices and guidelines, and leading the national effort in performance and reliability testing, and consensus standards, codes, and certification program development and implementation—thereby ensuring that PV systems meet customers' needs and expectations. A summary of project activities, accomplishments, and future plans is provided and highlighted by an overview of PV system test-procedure and standards development.

  17. Low concentrator PV optics optimization

    Science.gov (United States)

    Sharp, Leonard; Chang, Ben

    2008-08-01

    Purpose: Cost reduction is a major focus of the solar industry. Thin film technologies and concentration systems are viable ways to reducing cost, with unique strengths and weakness for both. Most of the concentrating PV work focuses on high concentration systems for reducing energy cost. Meanwhile, many believe that low concentrators provide significant cost reduction potential while addressing the mainstream PV market with a product that acts as a flat panel replacement. This paper analyzes the relative benefit of asymmetric vs. symmetric optics for low-concentrators in light of specific PV applications. Approach: Symmetric and asymmetric concentrating PV module performance is evaluated using computer simulation to determine potential value across various geographic locations and applications. The selected optic design is modeled against standard cSi flat panels and thin film to determine application fit, system level energy density and economic value. Results: While symmetric designs may seem ideal, asymmetric designs have an advantage in energy density. Both designs are assessed for aperture, optimum concentration ratio, and ideal system array configuration. Analysis of performance across climate specific effects (diffuse, direct and circumsolar) and location specific effects (sunpath) are also presented. The energy density and energy production of low concentrators provide a compelling value proposition. More significantly, the choice of optics for a low concentrating design can affect real world performance. With the goal of maximizing energy density and return on investment, this paper presents the advantages of asymmetric optic concentration and illustrates the value of this design within specific PV applications.

  18. Flexible packaging for PV modules

    Science.gov (United States)

    Dhere, Neelkanth G.

    2008-08-01

    Economic, flexible packages that provide needed level of protection to organic and some other PV cells over >25-years have not yet been developed. However, flexible packaging is essential in niche large-scale applications. Typical configuration used in flexible photovoltaic (PV) module packaging is transparent frontsheet/encapsulant/PV cells/flexible substrate. Besides flexibility of various components, the solder bonds should also be flexible and resistant to fatigue due to cyclic loading. Flexible front sheets should provide optical transparency, mechanical protection, scratch resistance, dielectric isolation, water resistance, UV stability and adhesion to encapsulant. Examples are Tefzel, Tedlar and Silicone. Dirt can get embedded in soft layers such as silicone and obscure light. Water vapor transmittance rate (WVTR) of polymer films used in the food packaging industry as moisture barriers are ~0.05 g/(m2.day) under ambient conditions. In comparison, light emitting diodes employ packaging components that have WVTR of ~10-6 g/(m2.day). WVTR of polymer sheets can be improved by coating them with dense inorganic/organic multilayers. Ethylene vinyl acetate, an amorphous copolymer used predominantly by the PV industry has very high O2 and H2O diffusivity. Quaternary carbon chains (such as acetate) in a polymer lead to cleavage and loss of adhesional strength at relatively low exposures. Reactivity of PV module components increases in presence of O2 and H2O. Adhesional strength degrades due to the breakdown of structure of polymer by reactive, free radicals formed by high-energy radiation. Free radical formation in polymers is reduced when the aromatic rings are attached at regular intervals. This paper will review flexible packaging for PV modules.

  19. Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, L.; Gostein, M.; Emery, K.

    2012-09-01

    As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

  20. Solar PV. Innovators talking; Zon PV. Innovators aan het woord

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-02-15

    Qualitative studies have been conducted of the results of completed projects focused on energy innovation, spread over the seven themes of the top sector Energy: Energy saving in industry, Energy conservation in the built environment, Gas, Bio-energy, Smart grids, Offshore Wind, Solar PV. This provides insight into the follow-up activities and lessons of some EOS (Energy Research Subsidy) completed projects with the aim to inspire, connect and strengthen the TKIs (Topconsortia for Knowledge and Innovation) and individual companies and researchers working on energy innovation. This report concerns the research on solar PV [Dutch] Er is een kwalitatief onderzoek uitgevoerd naar de resultaten van afgeronde projecten gericht op energie-innovatie, verdeeld over de zeven thema's van de topsector Energie: Energiebesparing in de industrie; Energiebesparing in de gebouwde omgeving; Gas; Bio-energie; Smart grids; Wind op zee; Zon-pv. Daarmee wordt inzicht gegeven in de vervolgactiviteiten en lessen van een aantal afgesloten EOS-projecten (Energie Onderzoek Subsidie) met het oog op het inspireren, verbinden en versterken van de TKI's (Topconsortia voor Kennis en Innovatie) en individuele bedrijven en onderzoekers die werken aan energie-innovatie. Dit rapport betreft het onderzoek naar zon PV.

  1. Van lPv4 naar lPv6

    NARCIS (Netherlands)

    Luiijf, H.A.M.

    2008-01-01

    Organisaties die het Internet Protocol(IP) gebruiken voor beveiligingsdoeleinden en aanbieders van beveiligingsproducten ontkomen de komende jaren niet aan de overgang naar het nieuwe protocol lPv6. Enerzijds is het gelukkig dat die overgang niet op één dag wereldwijd zal plaatsvinden, er is geen 'I

  2. Progress & Frontiers in PV Performance

    Energy Technology Data Exchange (ETDEWEB)

    Deline, Chris; DiOrio, Nick; Jordan, Dirk; Toor, Fatima

    2016-09-12

    PowerPoint slides for a presentation given at Solar Power International 2016. Presentation includes System Advisor Model (SAM) introduction and battery modeling, bifacial PV modules and modeling, shade modeling and module level power electronics (MLPE), degradation rates, and PVWatts updates and validation.

  3. PV gold rush in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Daniela

    2011-07-01

    As a result of the Green Energy Act, the installed PV capacity in the Canadian province of Ontario has tripled in the year 2010. A generous feed-in tariff, aiming at maximum local added value, has attracted numerous international manufacturers. However, the rigorous rules committing the companies to 60 % inland production have provoked harsh criticism. (orig.)

  4. Comparative and functional genomics reveals genetic diversity and determinants of host specificity among reference strains and a large collection of Chinese isolates of the phytopathogen Xanthomonas campestris pv. campestris

    OpenAIRE

    He, Yong-Qiang; Zhang, Liang; Jiang, Bo-Le; Zhang, Zheng-Chun; Xu, Rong-Qi; Tang, Dong-Jie; Qin, Jing; Jiang, Wei; Zhang, Xia; LIAO, JIE; Cao, Jin-Ru; Zhang, Sui-Sheng; Wei, Mei-Liang; Liang, Xiao-Xia; Lu, Guang-Tao

    2007-01-01

    Background Xanthomonas campestris pathovar campestris (Xcc) is the causal agent of black rot disease of crucifers worldwide. The molecular genetic diversity and host specificity of Xcc are poorly understood. Results We constructed a microarray based on the complete genome sequence of Xcc strain 8004 and investigated the genetic diversity and host specificity of Xcc by array-based comparative genome hybridization analyses of 18 virulent strains. The results demonstrate that a genetic core comp...

  5. Assessment of genetic diversity of Xanthomonas oryzae pv. oryzae

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@Bacterial blight of rice, caused by Xanthomonas oryzae pv. Oryzae(Xoo. ), is one of the major rice diseases in China. Making clear the shift of genetic diversity of the pathogen will provide important information for rice breeding. Strains collected from 11 provinces located in Southern region of the Changjiang River in China were assessed by using inoculation method and IS-PCR(Insertion Sequence-Based Polymerase Chain Reaction) analysis.

  6. Overview of Scientific Issues Involved in Selection of Polymers for PV Applications: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kempe, M.

    2011-07-01

    Encapsulant materials used in photovoltaic (PV) modules serve multiple purposes. They physically hold components in place, provide electrical insulation, reduce moisture ingress, optically couple superstrate materials (e.g., glass) to PV cells, protect components from mechanical stress by mechanically de-coupling components via strain relief, and protect materials from corrosion. To do this, encapsulants must adhere well to all surfaces, remain compliant, and transmit light after exposure to temperature, humidity, and UV radiation histories. Here, a brief review of some of the polymeric materials under consideration for PV applications is provided, with an explanation of some of their advantages and disadvantages.

  7. The case for better PV forecasting

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Efthymiou, Venizelos; Graditi, Giorgio

    2016-01-01

    Rising levels of PV penetration mean increasingly sophisticated forecasting technologies are needed to maintain grid stability and maximise the economic value of PV systems. The Grid Integration working group of the European Technology and Innovation Platform – Photovoltaics (ETIP PV) shares...... the results of its ongoing research into the advantages and limitations of current forecasting technologies....

  8. Multilocus sequence typing of Pseudomonas syringae sensu lato confirms previously described genomospecies and permits rapid identification of P. syringae pv. coriandricola and P. syringae pv. apii causing bacterial leaf spot on parsley.

    Science.gov (United States)

    Bull, Carolee T; Clarke, Christopher R; Cai, Rongman; Vinatzer, Boris A; Jardini, Teresa M; Koike, Steven T

    2011-07-01

    Since 2002, severe leaf spotting on parsley (Petroselinum crispum) has occurred in Monterey County, CA. Either of two different pathovars of Pseudomonas syringae sensu lato were isolated from diseased leaves from eight distinct outbreaks and once from the same outbreak. Fragment analysis of DNA amplified between repetitive sequence polymerase chain reaction; 16S rDNA sequence analysis; and biochemical, physiological, and host range tests identified the pathogens as Pseudomonas syringae pv. apii and P. syringae pv. coriandricola. Koch's postulates were completed for the isolates from parsley, and host range tests with parsley isolates and pathotype strains demonstrated that P. syringae pv. apii and P. syringae pv. coriandricola cause leaf spot diseases on parsley, celery, and coriander or cilantro. In a multilocus sequence typing (MLST) approach, four housekeeping gene fragments were sequenced from 10 strains isolated from parsley and 56 pathotype strains of P. syringae. Allele sequences were uploaded to the Plant-Associated Microbes Database and a phylogenetic tree was built based on concatenated sequences. Tree topology directly corresponded to P. syringae genomospecies and P. syringae pv. apii was allocated appropriately to genomospecies 3. This is the first demonstration that MLST can accurately allocate new pathogens directly to P. syringae sensu lato genomospecies. According to MLST, P. syringae pv. coriandricola is a member of genomospecies 9, P. cannabina. In a blind test, both P. syringae pv. coriandricola and P. syringae pv. apii isolates from parsley were correctly identified to pathovar. In both cases, MLST described diversity within each pathovar that was previously unknown.

  9. Draft Genome Sequence of Pseudomonas syringae pv. syringae ALF3 Isolated from Alfalfa.

    Science.gov (United States)

    Harrison, James; Dornbusch, Melinda R; Samac, Deborah; Studholme, David J

    2016-02-11

    We report here the annotated draft genome sequence of Pseudomonas syringae pv. syringae strain ALF3, isolated in Wyoming. A comparison of this genome sequence with those of closely related strains of P. syringae adapted to other hosts will facilitate research into interactions between this pathogen and alfalfa.

  10. Grid Integrated Distributed PV (GridPV) Version 2.

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2014-12-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functio ns are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in th e OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function i n the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  11. Lightweight IMM PV Flexible Blanket Assembly

    Science.gov (United States)

    Spence, Brian

    2015-01-01

    Deployable Space Systems (DSS) has developed an inverted metamorphic multijunction (IMM) photovoltaic (PV) integrated modular blanket assembly (IMBA) that can be rolled or z-folded. This IMM PV IMBA technology enables a revolutionary flexible PV blanket assembly that provides high specific power, exceptional stowed packaging efficiency, and high-voltage operation capability. DSS's technology also accommodates standard third-generation triple junction (ZTJ) PV device technologies to provide significantly improved performance over the current state of the art. This SBIR project demonstrated prototype, flight-like IMM PV IMBA panel assemblies specifically developed, designed, and optimized for NASA's high-voltage solar array missions.

  12. Lightning protection of PV systems

    OpenAIRE

    Pons, Enrico; Tommasini, Riccardo

    2013-01-01

    Lightning strikes can affect photovoltaic (PV) generators and their installations, involving also the inverter's electronics. It is therefore necessary to evaluate the risk connected to lightning strikes in order to adopt the correct protective measures for the system. The Standard IEC (EN) 62305-2 reports the procedures for the risk calculation and for the choice of proper lightning protection systems. Usually the technical guidelines suggest protecting with SPDs (surge protective devices) b...

  13. Characterization of Xanthomonas spp. strains by bacteriocins Caracterização de isolados de Xanthomonas spp. por bacterocinas

    Directory of Open Access Journals (Sweden)

    Marcel Bonini

    2007-03-01

    Full Text Available Twenty-five strains of Xanthomonas axonopodis pv. citri and 14 strains of Xanthomonas spp. were tested for bacteriocin production. X. axonopodis pv. passiflorae strains were sensitive to the bacteriocins produced by the 25 X. axonopodis pv. citri strains evaluated in this study while strains of X. axonopodis pv. manihotis and X. campestris pv. campestris showed variable sensitivity. Only five of the 25 X. axonopodis pv. citri strains were not inhibited by the bacteriocins produced by the two X. axonopodis pv. passiflorae strains. The bacteriocins produced by the Xanthomonas axonopodis pv. citri (FDC-806 and X. axonopodis pv. passiflorae (Mar-2850 A strains were thermolabile, resistant to lysozyme and sensitive to DNAse. The bacteriocin produced by X. axonopodis pv. passiflorae was resistant to the action of proteinase K, trypsin and RNAse while the bacteriocin produced by X. axonopodis pv. citri was sensitive to these enzymes. The bacteriocins produced by X. axonopodis pv. passiflorae and X. axonopodis pv. citri were called passifloricin and citricin, respectively.Vinte e cinco isolados de Xanthomonas axonopodis pv. citri e 14 isolados de Xanthomonas spp. foram comparados a fim de verificar a capacidade de produção de bacteriocina e a sua sensibilidade. Isolados de X. axonopodis pv. passiflorae foram sensíveis às bacteriocinas produzidas por 25 isolados de X. axonopodis pv. citri avaliados e os isolados de X. axonopodis pv. manihotis e X. campestris pv. campestris apresentaram sensibilidade variável. Dos 25 isolados de X. axonopodis pv. citri apenas cinco não foram inibidos pelas bacteriocinas produzidas por dois isolados de X. axonopodis pv. passiflorae. As bacteriocinas produzidas pelos isolados de X. axonopodis pv. citri (FDC-806 e de X. axonopodis pv. passiflorae (Mar-2850 A foram termolábeis e resistentes à lisozima e sensíveis a DNAse. A bacteriocina produzida pelo isolado de X. axonopodis pv. passiflorae foi resistente à a

  14. Pseudomonas syringae pv. tabaci in papaya seedlings Pseudomonas syringae pv. tabaci em plântulas de mamoeiro

    Directory of Open Access Journals (Sweden)

    Luís Otávio S. Beriam

    2006-03-01

    Full Text Available The natural occurrence of Pseudomonas syringae pv. tabaci causing leaf spot symptoms in papaya seedlings is reported. The pathogen was identified through biochemical, physiological, serological, and molecular assays and artificial inoculations in papaya plants. It was also shown that the strains were pathogenic to bean and tobacco plants. The restriction patterns obtained with Afa I, Alu I, Dde I, Hae III, Hpa II, Hinf I, Sau 3A I and Taq I of the PCR-RFLP of 16S-23S DNAr were identical to the P. s. pv. tabaci patterns. Primers corresponding to hrpL gene of P. syringae were also tested and the results grouped the papaya strains with P s. pv. tabaci. Bacterial strains were deposited at Coleção de Culturas IBSBF, Instituto Biológico, Campinas, Brazil, under access numbers 1687 and 1822.É relatada a ocorrência natural de Pseudomonas syringae pv. tabaci causando sintomas de lesões foliares em plântulas de mamoeiro. O patógeno foi identificado por meio de testes bioquímicos, fisiológicos, serológicos e moleculares, além de ensaios de patogenicidade em plantas de mamoeiro, feijoeiro e fumo. Os padrões de restrição obtidos com as enzimas Afa I, Alu I, Dde I, Hae III, Hpa II, Hinf I, Sal 3A I e Taq I, utilizando-se a técnica de PCR-RLFP da região espaçadora 16S-23S do DNA ribossômico, foram idênticos àqueles apresentados para P. s. pv. tabaci. Primers correspondentes ao gene hrpL de P. syringae foram também testados e os resultados obtidos permitiram agrupar as linhagens isoladas de mamão com P. s. pv. tabaci. Linhagens bacterianas estão depositadas na coleção de culturas IBSBF, Instituto Biológico, Campinas, sob n. 1687 e 1822.

  15. Differences between Pseudomonas syringae pv. syringae B728a and Pantoea agglomerans BRT98 in epiphytic and endophytic colonization of leaves.

    Science.gov (United States)

    Sabaratnam, Siva; Beattie, Gwyn A

    2003-02-01

    The leaf colonization strategies of two bacterial strains were investigated. The foliar pathogen Pseudomonas syringae pv. syringae strain B728a and the nonpathogen Pantoea agglomerans strain BRT98 were marked with a green fluorescent protein, and surface (epiphytic) and subsurface (endophytic) sites of bean and maize leaves in the laboratory and the field were monitored to see if populations of these strains developed. The populations were monitored using both fluorescence microscopy and counts of culturable cells recovered from nonsterilized and surface-sterilized leaves. The P. agglomerans strain exclusively colonized epiphytic sites on the two plant species. Under favorable conditions, the P. agglomerans strain formed aggregates that often extended over multiple epidermal cells. The P. syringae pv. syringae strain established epiphytic and endophytic populations on asymptomatic leaves of the two plant species in the field, with most of the P. syringae pv. syringae B728a cells remaining in epiphytic sites of the maize leaves and an increasing number occupying endophytic sites of the bean leaves in the 15-day monitoring period. The epiphytic P. syringae pv. syringae B728a populations appeared to originate primarily from multiplication in surface sites rather than from the movement of cells from subsurface to surface sites. The endophytic P. syringae pv. syringae B728a populations appeared to originate primarily from inward movement through the stomata, with higher levels of multiplication occurring in bean than in maize. A rainstorm involving a high raindrop momentum was associated with rapid growth of the P. agglomerans strain on both plant species and with rapid growth of both the epiphytic and endophytic populations of the P. syringae pv. syringae strain on bean but not with growth of the P. syringae pv. syringae strain on maize. These results demonstrate that the two bacterial strains employed distinct colonization strategies and that the epiphytic and

  16. PV output smoothing with energy storage.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Schoenwald, David Alan

    2012-03-01

    This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

  17. High-efficiency Transformerless PV Inverter Circuits

    OpenAIRE

    Chen, Baifeng

    2015-01-01

    With worldwide growing demand for electric energy, there has been a great interest in exploring photovoltaic (PV) sources. For the PV generation system, the power converter is the most essential part for the efficiency and function performance. In recent years, there have been quite a few new transformerless PV inverters topologies, which eliminate the traditional line frequency transformers to achieve lower cost and higher efficiency, and maintain lower leakage current as well. With an ov...

  18. Genetic diversity of Xanthomonas axonopodis pv. citri based on plasmid profile and pulsed field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Carvalho Flávia Maria de Souza

    2005-01-01

    Full Text Available Xanthomonas axonopodis pv. citri strains that cause disease in citrus were investigated by pulsed field and plasmid profile analysis. For the first method, genomic DNA was digested by the rare-cutting enzymes Xba I and Vsp I. The strains evaluated were collected in seven different States of Brazil and in Argentina, Bolivia, Paraguay and Uruguay. Genetic variability was found among strains of X. axonopodis pv. citri from different geographical areas Argentina, Bolivia and Uruguay, with similarities varying from 0.62 to 0.83. However, the strains collected in Brazil, despite being from different States, have shown a genetic similarity ranging from 0.83 to 1.00. Cluster analysis showed a relationship between genomic similarity and geographical origin of the strains. Plasmids were observed in all strains, with a total of five different plasmids, with sizes between 57.7 and 83.0 kilobases. The 72.6 kb plasmid was the most frequent, present in 15 out of 22 strains, while the 68.1 kb plasmid was observed in two strains only. Although the plasmid diversity detected in the present study was not very great, the X. axonopodis pv. citri strains evaluated showed a considerable degree of diversity with regard to this extrachromosomal genetic element.

  19. P.V. Jensen-Klint

    DEFF Research Database (Denmark)

    Jensen, Thomas Bo

    2006-01-01

    Bogen præsenterer og analyserer P.V. Jensen-Klints samlede arkitekturproduktion samt en mindre del af hans øvrige kunstneriske arbejder. Bogen rummer en grundig biografi om P.V. Jensen-Klints liv og gerning og præsenterer for første gang hans samlede arkitekturproduktion.......Bogen præsenterer og analyserer P.V. Jensen-Klints samlede arkitekturproduktion samt en mindre del af hans øvrige kunstneriske arbejder. Bogen rummer en grundig biografi om P.V. Jensen-Klints liv og gerning og præsenterer for første gang hans samlede arkitekturproduktion....

  20. Electrical PV array reconfiguration strategy for energy extraction improvement in grid-connected PV systems

    OpenAIRE

    2009-01-01

    This paper applies a dynamical electrical array reconfiguration (EAR) strategy on the photovoltaic (PV) generator of a grid-connected PV system based on a plant-oriented configuration, in order to improve its energy production when the operating conditions of the solar panels are different. The EAR strategy is carried out by inserting a controllable switching matrix between the PV generator and the central inverter, which allows the electrical reconnection of the available PV modules. A...

  1. 46 CFR 153.355 - PV venting systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false PV venting systems. 153.355 Section 153.355 Shipping... Systems § 153.355 PV venting systems. When Table 1 requires a PV venting system, the cargo tank must have a PV valve in its vent line. The PV valve must be located between the tank and any connection...

  2. Origin of the Outbreak in France of Pseudomonas syringae pv. actinidiae Biovar 3, the Causal Agent of Bacterial Canker of Kiwifruit, Revealed by a Multilocus Variable-Number Tandem-Repeat Analysis

    Science.gov (United States)

    Cunty, A.; Cesbron, S.; Poliakoff, F.; Jacques, M.-A.

    2015-01-01

    The first outbreaks of bacterial canker of kiwifruit caused by Pseudomonas syringae pv. actinidiae biovar 3 were detected in France in 2010. P. syringae pv. actinidiae causes leaf spots, dieback, and canker that sometimes lead to the death of the vine. P. syringae pv. actinidifoliorum, which is pathogenic on kiwi as well, causes only leaf spots. In order to conduct an epidemiological study to track the spread of the epidemics of these two pathogens in France, we developed a multilocus variable-number tandem-repeat (VNTR) analysis (MLVA). MLVA was conducted on 340 strains of P. syringae pv. actinidiae biovar 3 isolated in Chile, China, France, Italy, and New Zealand and on 39 strains of P. syringae pv. actinidifoliorum isolated in Australia, France, and New Zealand. Eleven polymorphic VNTR loci were identified in the genomes of P. syringae pv. actinidiae biovar 3 ICMP 18744 and of P. syringae pv. actinidifoliorum ICMP 18807. MLVA enabled the structuring of P. syringae pv. actinidiae biovar 3 and P. syringae pv. actinidifoliorum strains in 55 and 16 haplotypes, respectively. MLVA and discriminant analysis of principal components revealed that strains isolated in Chile, China, and New Zealand are genetically distinct from P. syringae pv. actinidiae strains isolated in France and in Italy, which appear to be closely related at the genetic level. In contrast, no structuring was observed for P. syringae pv. actinidifoliorum. We developed an MLVA scheme to explore the diversity within P. syringae pv. actinidiae biovar 3 and to trace the dispersal routes of epidemic P. syringae pv. actinidiae biovar 3 in Europe. We suggest using this MLVA scheme to trace the dispersal routes of P. syringae pv. actinidiae at a global level. PMID:26209667

  3. 40 CFR 180.1261 - Xanthomonas campestris pv. vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages.

    Science.gov (United States)

    2010-07-01

    ... and Pseudomonas syringae pv. tomato specific Bacteriophages. 180.1261 Section 180.1261 Protection of.... vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages. An exemption from the requirement of... syringae pv. tomato specific bacteriophages in or on pepper and tomato. ...

  4. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  5. Multifunctionality of PV shells; Multifunktionalitaet von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Erban, C. [Saint-Gobain Glass Solar, Aachen (Germany)

    2000-08-01

    Integrated PV systems have come a long way since the construciton of the first solar building shell eight years ago. All technical problems have be solved, and a multitude of solar wall elements are now available that enable architects and planners to design their own customised solar building. [German] Der Einsatz von gebaeudeintegrierter Photovoltaik hat in den nunmehr acht Jahren seit dem Bau der ersten Solarfassade erhebliche Fortschritte gemacht. In technischer Hinsicht ist heute nahezu alles moeglich. Der Umsetzung der einstigen Vision 'Jedem Gebaeude seine Solaranlage' steht heute nichts mehr entgegen, zumal zahlreiche Foerdermoeglichkeiten existieren. Die Vielzahl der Einsatz- und Kombinationsmoeglichkeiten von Solar-Fassadenelementen versetzen Planer und Architekten in die Lage, ihrer individuellen Idee einer gebaeudeintegrierten Solaranlage Gestalt zu geben. (orig.)

  6. Crestamento foliar, nova sintomatologia em algodoeiro causada por Xanthomonas axonopodis pv. malvacearum Cotton leaf blight, a new symptomatology caused by Xanthomonas axonopodis pv. malvacearum

    Directory of Open Access Journals (Sweden)

    Valdemar Atílio Malavolta Jr.

    2008-06-01

    Full Text Available Foi observada recentemente no Estado de São Paulo uma nova sintomatologia em algodoeiro cv. Makina, IAC 24 e Detaopal, causada por Xanthomonas axonopodis pv. malvacearum (Xam, denominada "crestamento foliar". Caracteriza-se por crestamento foliar, geralmente acompanhado por halo clorótico, podendo também causar sintomas de "V" invertido, a partir dos bordos foliares. Linhagens de Xam foram comparadas, por meio de testes de patogenicidade, bioquímicos, sorológicos, culturais e PCR-RFLP da região espaçadora 16S-23S DNAr. Independentemente do tipo de sintoma, as linhagens apresentaram características e perfis idênticos aos apresentados pela linhagem tipo, confirmando a identidade dos isolados como Xanthomonas axonopodis pv. malvacearum.Recently a new symptomatology on cotton plants (cv. Makina, IAC 24 and Deltaopal caused by Xanthomonas axonopodis pv. malvacearum (Xam was observed in São Paulo state, Brazil, and named "bacterial leaf blight". The symptom was characterized by leaf blight, generally exhibiting chlorotic haloes and sometimes showing V-shaped lesions beginning at the leaves' border. Strains of Xam responsible for typical angular leaf spots and bacterial leaf blight were compared through pathological, biochemical, serological, cultural and RFLP-PCR tests of the 16S-23S spacer region. Independently of the symptom type, the strains exhibited characteristics and profiles that were identical to those exhibited by the type strain, which confirms the isolates identity Xanthomonas axonopodis pv. malvacearum

  7. PV integration into a CSP plant

    Science.gov (United States)

    Carvajal, Javier López; Barea, Jose M.; Barragan, Jose; Ortega, Carlos

    2017-06-01

    This paper describes a preliminary techno-economic analysis of the integration of a PV plant into an optimized Parabolic Trough Plant in order to reduce the online consumptions and thus, increase the net electricity injected into the grid. The idea is to assess the feasibility of such project and see what configuration would be the optimal. An extra effort has been made in terms of modelling as the analysis has to be done to the integrated CSP + PV plant instead of analyzing them independently. Two different technologies have been considered for the PV plant, fix and one-axis tracking. Additionally three different scenarios have been considered for the CSP plant auxiliary consumptions as they are essential for determining the optimal PV plant (the higher the auxiliary consumption the higher the optimal PV plant). As could be expected, the results for all cases with PV show an improvement in terms of electricity generation and also in terms of LCOE with respect to the CSP plant. Such improvement is slightly higher with tracking technology for this specific study. Although this exercise has been done to an already designed CSP plant (so only the PV plant had to be optimized), the methodology could be applied for the optimization of an integrated CSP + PV plant during the design phase.

  8. Distributed PV Adoption - Sensitivity to Market Factors

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2016-02-01

    NREL staff used the dSolar (distributed solar) model to forecast the adoption of distributed, behind-the-meter PV through the year 2050 for 9 different scenarios. The scenarios varied in their assumptions about a carbon tax, the cost of PV systems in the future, and what credit would be given for excess generation once current net metering policies expire.

  9. Global PV markets and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Wolfsegger, Cristoph [European Photolvoltaic Industry Association (EPIA), Brussels, Belgium (Belgium)

    2007-06-15

    This presentation mainly talks about the global importance of the PV industry, not only in the environmental sphere but also in the economic sphere. It is firstly given the major information of the European Photovoltaic Industry Association (EPIA), where there can be found the lists of those full member countries that work as: components manufacturers, consulting, and associate members. Then, it is given a briefly explanation about the Alliance for Rural Electrification (ARE), and the reasons why the -PV systems- are almost the panacea to both the energy and the environmental issue. In addition, it is given the most relevant information about how to implement this system in those regions that have not yet implemented it. Besides, there are explained some of the benefits that this system has. It is shortly explained how this system is working in German and it is also shown a comparison chart about the photovoltaic feed-in tariffs. There are shown some graphics and charts having information related to the global markets and the global installations of PV systems and other issues related to them. [Spanish] Esta presentacion habla principalmente acerca de la importancia que hoy en dia tiene la industria fotovoltaica alrededor del mundo, esto no solo ocurre en el ambito ambiental sino tambien en el economico. En la primer parte se muestra la informacion mas importante acerca de la Asociacion Europea de la Industria Fotovoltaica (EPIA por sus siglas en ingles), en donde se encuentran las listas de los paises que son miembros permanentes trabajando como: fabricantes de componentes, asesores y miembros asociados. Enseguida, se da, de manera escueta, una explicacion acerca de la ARE, asi como las razones por las que los sistemas fotovoltaicos son casi la panacea tanto para los problemas ambientales como para los energeticos. Ademas, se explica la informacion mas relevante acerca de como implementar este sistema en aquellas partes del mundo que todavia no lo han realizado

  10. Optimal design of PV and HP system

    DEFF Research Database (Denmark)

    Nepper-Rasmussen, Bjarke Christian; Rasmussen, Theis Bo

    2015-01-01

    electric energy demand of the HP to hours where excess PV power is present. The self-consumption of the PV energy affects the overall net present value (NPV). In this paper, a method which maximizes the NPV by finding the cost-optimal combination of PV, HP and BT sizes, is proposed. Results show...... that the thermal storage with a BT is a better investment than a PV system without HP or no investment. Furthermore, it showed that the optimization model developed in this project is capable of finding the optimal combination of component sizes based on our data....... is described, where the thermal energy is stored in a buffer tank (BT) capable of dispersing heat to either the heating system of a house or a hot water tank, for later use. The thermal storage solution including a BT can increase the self-consumption of residentially produced PV power and thereby shift...

  11. Antagonism of Bacillus spp. against Xanthomonas campestris pv. campestris

    Directory of Open Access Journals (Sweden)

    Leila Monteiro

    2005-01-01

    Full Text Available The antagonism of eight Bacillus isolates was investigated against nine strains of Xanthomonas campestris pv. campestris (causal agent of crucifers black rot to assess the role of lipopeptides in this process. Antimicrobial and hemolytic (surfactant activity tests were performed in vitro using agar diffusion methods. Antibiosis and hemolysis were positive for four Bacillus isolates against all X. campestris pv. campestris strains. The correlation observed between antimicrobial and hemolytic activities indicated that lipopeptides were involved in the antibiosis mechanism of the studied antagonists. Fermentation studies were carried out with the isolates that showed highest antimicrobial and hemolytic activities, to follow up growth and production of bioactive and surfactant compounds. Production of bioactive and surfactant compounds was observed during the late growth phase of the Bacillus isolates.Investigação sobre o antagonismo de oito isolados de Bacillus: B. subtilis R14, B. megaterium pv. cerealis RAB7, B. megaterium pv. cerealis C211, B. megaterium C116, Bacillus sp. RAB9, B. cereus C240, Bacillus sp. C11 e B. cereus C210, contra nove linhagens de X. campestris pv. campestris (bactéria responsável pela podridão negra das crucíferas foi realizada para se verificar a participação de lipopeptídeos neste mecanismo. Testes de atividades antimicrobiana e hemolítica (surfactante foram realizados, utilizando-se o método de difusão em ágar. Antibiose e hemólise foram positivas para quatro isolados de Bacillus: R14, RAB7, C116 e C210. A correlação observada entre as atividades antimicrobiana e a hemolítica indica que lipopeptídeos estão envolvidos no mecanismo de antibiose dos isolados investigados. As fermentações foram realizadas com os isolados que demonstraram melhores resultados nos testes de atividades antimicrobiana e hemolítica: R14, RAB7 e C116, para acompanhar o crescimento e a produção de compostos bioativos e

  12. Power of design - the future of building-integrated PV

    Energy Technology Data Exchange (ETDEWEB)

    Abbate, Cinzia [ENEL, Rome (Italy). Officine di Architettura

    2001-04-01

    This paper discusses strategies to make building integrated photovoltaic (PV) systems more acceptable and to allow PV material to compete with conventional construction material. The history of developments in building integration and difficulties encountered by architects wishing to use PV products are explored, and the Dutch Amersfoot project in Utrecht involving a new suburb of 501 house covered with PV panels is described. Questions raised regarding architectural integration of PV systems, and PV systems and the construction market are discussed. The Italian PV programme, financial and political constraints, and the positioning of PV on existing structures are reported.

  13. Multifunctional a-Si PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Peippo, K.; Lund, P.; Vartiainen, E. [Helsinki Univ. of Technology, Otaniemi (Finland). Advanced Energy Systems

    1998-10-01

    The optimal use of the various forms of solar energy (passive, active, daylighting, photovoltaics) in buildings calls for an optimal integration of the technologies. As energy conservation potential in space heating may soon be exhausted, electricity efficiency and on-site generation will play an increasing role in energy-conscious building design. There, dispersed PV systems integrated into buildings show a significant market potential, due to a number of benefits: no extra land area is required, PV-array may replace conventional cladding materials and become a building element. Moreover, the produced PV-electricity is more valuable for the building owner than for an electric utility

  14. Identification, characterization and antigenicity of the Plasmodium vivax rhoptry neck protein 1 (PvRON1

    Directory of Open Access Journals (Sweden)

    Patarroyo Manuel E

    2011-10-01

    Full Text Available Abstract Background Plasmodium vivax malaria remains a major health problem in tropical and sub-tropical regions worldwide. Several rhoptry proteins which are important for interaction with and/or invasion of red blood cells, such as PfRONs, Pf92, Pf38, Pf12 and Pf34, have been described during the last few years and are being considered as potential anti-malarial vaccine candidates. This study describes the identification and characterization of the P. vivax rhoptry neck protein 1 (PvRON1 and examine its antigenicity in natural P. vivax infections. Methods The PvRON1 encoding gene, which is homologous to that encoding the P. falciparum apical sushi protein (ASP according to the plasmoDB database, was selected as our study target. The pvron1 gene transcription was evaluated by RT-PCR using RNA obtained from the P. vivax VCG-1 strain. Two peptides derived from the deduced P. vivax Sal-I PvRON1 sequence were synthesized and inoculated in rabbits for obtaining anti-PvRON1 antibodies which were used to confirm the protein expression in VCG-1 strain schizonts along with its association with detergent-resistant microdomains (DRMs by Western blot, and its localization by immunofluorescence assays. The antigenicity of the PvRON1 protein was assessed using human sera from individuals previously exposed to P. vivax malaria by ELISA. Results In the P. vivax VCG-1 strain, RON1 is a 764 amino acid-long protein. In silico analysis has revealed that PvRON1 shares essential characteristics with different antigens involved in invasion, such as the presence of a secretory signal, a GPI-anchor sequence and a putative sushi domain. The PvRON1 protein is expressed in parasite's schizont stage, localized in rhoptry necks and it is associated with DRMs. Recombinant protein recognition by human sera indicates that this antigen can trigger an immune response during a natural infection with P. vivax. Conclusions This study shows the identification and characterization of

  15. Using a nonparametric PV model to forecast AC power output of PV plants

    OpenAIRE

    Almeida, Marcelo Pinho; Perpiñan Lamigueiro, Oscar; Narvarte Fernández, Luis

    2015-01-01

    In this paper, a methodology using a nonparametric model is used to forecast AC power output of PV plants using as inputs several forecasts of meteorological variables from a Numerical Weather Prediction (NWP) model and actual AC power measurements of PV plants. The methodology was built upon the R environment and uses Quantile Regression Forests as machine learning tool to forecast the AC power with a confidence interval. Real data from five PV plants was used to validate the methodology, an...

  16. A Practical Optimization Method for Designing Large PV Plants

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Koutroulis, E.; Eyigun, S.

    2011-01-01

    Nowadays Photovoltaic (PV) plants have multi MW sizes, the biggest plants reaching tens of MW of capacity. Such large-scale PV plants are made up of several thousands of PV panels, each panel being in the range of 150-350W. This means that the design of a Large PV power plant is a big challenge...

  17. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  18. Distributed PV Adoption in Maine Through 2021

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2015-11-06

    NREL has used its dSolar (distributed solar) model to generate low-medium-high estimates of distributed PV adoption in Maine through 2021. This presentation gives a high-level overview of the model and modeling results.

  19. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault.......Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  20. Transformerless PV inverters. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Borup, U.

    2009-12-15

    Since the start of the project the market for grid connected PV inverters have developed further. When the project started three - phase inverter were only available in high power systems. The technology developed within this project will enable three phase technology also to be implemented in string inverters for system down to 10 kW. We expect this to be very attractive due to the increased demand for symmetrical feed-in to the grid. The project relevance is therefore high and the sector continues to develop very much driven by technology. Especially the inverter technology is getting a lot of focus. The inverter systems are expected to take a much larger role in supporting the electrical grid in the future. The technology platform developed within the project is prepared to be extended with these utility functionalities. The main results of the project were: 1) A new technology concept for transformer-less inverters has been demonstrated with a number of prototypes. 2) Efficiency above 97,7% has been proven. 3) Efficiency and Maximum power point tracking has been optimized to ensure that almost all energy produced of the panels is transferred to the grid. 4) The platform is developed with a very fast control board, which enables extended functionality as demanding grid supporting functions in the future. Details about cost price and details about the control loop implementation is excluded from the report due to the competitive situation for Danfoss Solar Inverters A/S. (LN)

  1. Addressing firefighter safety around solar PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Harris, B. [Sustainable Energy Technologies, Calgary, AB (Canada)

    2010-11-15

    The article discussed new considerations for installing photovoltaic (PV) systems that address the needs of fire service personnel. The presence of a PV system presents a multitude of dangers for firefighters, including electrical shock, the inhalation of toxic gases from being unable to cut a hole through the roof, falling debris and flying glass, and dead loading on a compromised structure and tripping on conduits. Mapping systems should be modified so that buildings with PV systems are identified for first responders, including firefighters who should learn that solar modules present an electrical hazard during the day but not at night; covering PV modules with foam or salvage covers may not shut the system down to a safe level; it takes a few moments for the power in PV modules to reduce to zero; and PV modules or conduit should never be cut, broke, chopped, or walked upon. The California Department of Forestry and Fire Protection recommends creating pathways and allowing easier access to the roof by setting the modules back from roof edges, creating a structurally sound pathway for firefighters to walk on and space to cut ventilation holes. However, the setback rule makes the economics of solar installation less viable for residential applications. The technological innovations aimed at addressing system safety all focus on limiting firefighter contact with live electrical components to within the extra-low-voltage (ELV) band. Some of the inverters on the market that support ELV system architecture were described. 1 fig.

  2. Updating Technical Screens for PV Interconnection: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Ellis, A.; Lynn, K.; Razon, A.; Key, T.; Kroposki, B.; Mather, B.; Hill, R.; Nicole, K.; Smith, J.

    2012-08-01

    Solar photovoltaics (PV) is the dominant type of distributed generation (DG) technology interconnected to electric distribution systems in the United States, and deployment of PV systems continues to increase rapidly. Considering the rapid growth and widespread deployment of PV systems in United States electric distribution grids, it is important that interconnection procedures be as streamlined as possible to avoid unnecessary interconnection studies, costs, and delays. Because many PV interconnection applications involve high penetration scenarios, the process needs to allow for a sufficiently rigorous technical evaluation to identify and address possible system impacts. Existing interconnection procedures are designed to balance the need for efficiency and technical rigor for all DG. However, there is an implicit expectation that those procedures will be updated over time in order to remain relevant with respect to evolving standards, technology, and practical experience. Modifications to interconnection screens and procedures must focus on maintaining or improving safety and reliability, as well as accurately allocating costs and improving expediency of the interconnection process. This paper evaluates the origins and usefulness of the capacity penetration screen, offers potential short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen.

  3. Recombination-prone bacterial strains form a reservoir from which epidemic clones emerge in agroecosystems.

    Science.gov (United States)

    Merda, Déborah; Bonneau, Sophie; Guimbaud, Jean-François; Durand, Karine; Brin, Chrystelle; Boureau, Tristan; Lemaire, Christophe; Jacques, Marie-Agnès; Fischer-Le Saux, Marion

    2016-04-05

    The acquisition of virulence-related genes through horizontal gene transfer can modify the pathogenic profiles of strains and lead to the emergence of new diseases. Xanthomonas arboricola is a bacterial species largely known for the damage it causes to stone and nut fruit trees worldwide. In addition to these host-specific populations called pathovars, many nonpathogenic strains have been identified in this species. Their evolutionary significance in the context of pathogen emergence is unknown. We looked at seven housekeeping genes amplified from 187 pathogenic and nonpathogenic strains isolated from various plants worldwide to analyze population genetics and recombination dynamics. We also examined the dynamics of the gains and losses of genes associated with life history traits (LHTs) during X. arboricola evolution. We discovered that X. arboricola presents an epidemic population structure. Successful pathovars of trees (i.e., pruni, corylina, and juglandis) are epidemic clones whose emergence appears to be linked to the acquisition of eight genes coding for Type III effectors. The other strains of this species are part of a recombinant network, within which LHT-associated genes might have been lost. We suggest that nonpathogenic strains, because of their high genetic diversity and propensity for recombination, may promote the emergence of pathogenic strains. This article is protected by copyright. All rights reserved. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  4. Structure of the O polysaccharide and serological classification of Pseudomonas syringae pv. ribicola NCPPB 1010.

    Science.gov (United States)

    Ovod, V V; Zdorovenko, E L; Shashkov, A S; Kocharova, N A; Knirel, Y A

    2000-04-01

    The O polysaccharide (OPS) moiety of the lipopolysaccharide (LPS) of a phytopathogenic bacterium Pseudomonas syringae pv. ribicola NCPPB 1010 was studied by sugar and methylation analyses, Smith degradation, and 1H- and 13C-NMR spectroscopy, including 2D COSY, TOCSY, NOESY and H-detected 1H,13C HMQC experiments. The OPS structure was elucidated, and shown to be composed of branched pentasaccharide repeating units (O repeats) of two types, major (1) and minor (2), differing in the position of substitution of one of the rhamnose residues. Both O repeats form structurally homogeneous blocks within the same polysaccharide molecule. Although P. syringae pv. ribicola NCPPB 1010 demonstrates genetic relatedness and similarity in the OPS chemical structure to some other P. syringae pathovars, it did not cross-react with any OPS-specific mAbs produced against heterologous P. syringae strains. Therefore, we propose to classify P. syringae pv. ribicola NCPPB 1010 in a new serogroup, O8.

  5. Optimization of PV-based energy production by dynamic PV-panel/inverter configuration

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    This paper investigates the possible increase in annual energy production of a PV system with more than one MPPT (maximum power point tracker) input channels under Nordic illumination conditions, in case a concept of dynamic switching of the PV panels is used at the inputs of the inverters....

  6. PV performance modeling workshop summary report.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua S.; Tasca, Coryne Adelle (SRA International, Inc., Fairfax, VA); Cameron, Christopher P.

    2011-05-01

    During the development of a solar photovoltaic (PV) energy project, predicting expected energy production from a system is a key part of understanding system value. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, annual energy yield (kWh/kWp) will vary among module technologies because of differences in response to low-light levels and temperature. A number of PV system performance models have been developed and are in use, but little has been published on validation of these models or the accuracy and uncertainty of their output. With support from the U.S. Department of Energy's Solar Energy Technologies Program, Sandia National Laboratories organized a PV Performance Modeling Workshop in Albuquerque, New Mexico, September 22-23, 2010. The workshop was intended to address the current state of PV system models, develop a path forward for establishing best practices on PV system performance modeling, and set the stage for standardization of testing and validation procedures for models and input parameters. This report summarizes discussions and presentations from the workshop, as well as examines opportunities for collaborative efforts to develop objective comparisons between models and across sites and applications.

  7. PV system field experience and reliability

    Science.gov (United States)

    Durand, Steven; Rosenthal, Andrew; Thomas, Mike

    1997-02-01

    Hybrid power systems consisting of battery inverters coupled with diesel, propane, or gasoline engine-driven electrical generators, and photovoltaic arrays are being used in many remote locations. The potential cost advantages of hybrid systems over simple engine-driven generator systems are causing hybrid systems to be considered for numerous applications including single-family residential, communications, and village power. This paper discusses the various design constraints of such systems and presents one technique for reducing hybrid system losses. The Southwest Technology Development Institute under contract to the National Renewable Energy Laboratory and Sandia National Laboratories has been installing data acquisition systems (DAS) on a number of small and large hybrid PV systems. These systems range from small residential systems (1 kW PV - 7 kW generator), to medium sized systems (10 kW PV - 20 kW generator), to larger systems (100 kW PV - 200 kW generator). Even larger systems are being installed with hundreds of kilowatts of PV modules, multiple wind machines, and larger diesel generators.

  8. Comparison of the complete genome sequences of Pseudomonassyringae pv. syringae B728a and pv. tomato DC3000.

    Energy Technology Data Exchange (ETDEWEB)

    Feil, Helene; Feil, William S.; Chain, Patrick; Larimer, Frank; DiBartolo, Genevieve; Copeland, Alex; Lykidis, Athanasios; Trong,Stephen; Nolan, Matt; Goltsman, Eugene; Thiel, James; Malfatti,Stephanie; Loper, Joyce E.; Lapidus, Alla; Detter, John C.; Land, Miriam; Richardson, Paul M.; Kyrpides, Nikos C.; Ivanova, Natalia; Lindow, StevenE.

    2005-04-01

    producing avariety of different symptoms depending on the host species and site ofinfection. For example, it causes leaf spot diseases that defoliateplants such as tomato, bean, soybean, trunk cankers, and so-called"blast" diseases on fruit, nut and ornamental species. Considerablevariation occurs both between and within different pathovars of P.syringae (1). Because of its importance as a plant pathogen, it has beenthe subject of much research, especially of its epidemiology andvirulence mechanisms (2). Pseudomonas syringae pv. syringae (Pss) strainB728a is typical of most strains of this pathovar in that it exhibits avery pronounced epiphytic phase on plants. Such strains achieve andmaintain large populations on healthy plants, where they are exposed tostressful conditions such as dryness and sunlight that are hostile tobacterial growth(2). Epiphytic Pss populations serve as inocula that cansubsequently invade plants and initiate disease. Pss strains are distinctfrom many P. syringae strains, such as P. syringae pv. tomato (Pst)strain DC3000, that poorly colonize the exterior of plants; these strainsmay be considered "endophytes" based on their ability to multiply mostlywithin the plant (3). True epiphytes such as Pss B728a often reachsurface populations of over 107 cells/g while strains such as Pst DC3000seldom exceed 105 cells/g (2, 3). Thus, these strains might be consideredto occupy different ends of the epiphytic/endophytic spectrum of plantcolonization as described by Beattie and Lindow (4). As a pathogen and anepiphyte, Pss B728a has evolved to exploit at least two distincthabitats: the leaf surface and apoplast. Because rapid changes intemperature, low water content, and incident solar radiation occur onleaf surfaces, it has been hypothesized that the epiphyte Pss B728aposseses more genes conferring environmental stress tolerance than theendophyte Pst DC3000 (4). Pss B728a also exhibits several traits such asice nucleation activity and SR production (2) that are

  9. Comparison of the complete genome sequences of Pseudomonassyringae pv. syringae B728a and pv. tomato DC3000.

    Energy Technology Data Exchange (ETDEWEB)

    Feil, Helene; Feil, William S.; Chain, Patrick; Larimer, Frank; DiBartolo, Genevieve; Copeland, Alex; Lykidis, Athanasios; Trong,Stephen; Nolan, Matt; Goltsman, Eugene; Thiel, James; Malfatti,Stephanie; Loper, Joyce E.; Lapidus, Alla; Detter, John C.; Land, Miriam; Richardson, Paul M.; Kyrpides, Nikos C.; Ivanova, Natalia; Lindow, StevenE.

    2005-04-01

    producing avariety of different symptoms depending on the host species and site ofinfection. For example, it causes leaf spot diseases that defoliateplants such as tomato, bean, soybean, trunk cankers, and so-called"blast" diseases on fruit, nut and ornamental species. Considerablevariation occurs both between and within different pathovars of P.syringae (1). Because of its importance as a plant pathogen, it has beenthe subject of much research, especially of its epidemiology andvirulence mechanisms (2). Pseudomonas syringae pv. syringae (Pss) strainB728a is typical of most strains of this pathovar in that it exhibits avery pronounced epiphytic phase on plants. Such strains achieve andmaintain large populations on healthy plants, where they are exposed tostressful conditions such as dryness and sunlight that are hostile tobacterial growth(2). Epiphytic Pss populations serve as inocula that cansubsequently invade plants and initiate disease. Pss strains are distinctfrom many P. syringae strains, such as P. syringae pv. tomato (Pst)strain DC3000, that poorly colonize the exterior of plants; these strainsmay be considered "endophytes" based on their ability to multiply mostlywithin the plant (3). True epiphytes such as Pss B728a often reachsurface populations of over 107 cells/g while strains such as Pst DC3000seldom exceed 105 cells/g (2, 3). Thus, these strains might be consideredto occupy different ends of the epiphytic/endophytic spectrum of plantcolonization as described by Beattie and Lindow (4). As a pathogen and anepiphyte, Pss B728a has evolved to exploit at least two distincthabitats: the leaf surface and apoplast. Because rapid changes intemperature, low water content, and incident solar radiation occur onleaf surfaces, it has been hypothesized that the epiphyte Pss B728aposseses more genes conferring environmental stress tolerance than theendophyte Pst DC3000 (4). Pss B728a also exhibits several traits such asice nucleation activity and SR production (2) that are

  10. Investigation of indirect benefits of PV rooftop in Thailand

    Science.gov (United States)

    Khumkrong, T.; Chuangchote, S.; Chenvidhya, D.; Kirtikara, K.

    2017-05-01

    Other than electricity generation, which is the direct benefit of PV rooftop, cooling load reduction due to PV shading is a benefit impact in the uses of PV rooftop. This report is a study of those indirect benefits of PV rooftop. Relation of shading of PV modules and reduction of cooling load was studied in a real testing cite at the office building of CES Solar Cell Testing Center (CSSC). Several data, i.e. solar radiation, rooftop temperatures before/after PV-panel installation, and electricity consumed by equipment, were monitored and collected. This data could be further estimated for cooling load via transient heat conduction approach.

  11. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    Directory of Open Access Journals (Sweden)

    Tirshu M.

    2011-12-01

    Full Text Available The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by means of specialized convertor is applied to lighting system. Additionally, paper present data measured by digital weather station (solar radiation and UV index, which is mounted near of PV cells and comparative analyze of solar energy with real energy generated by PV cells is done. Measured parameters by digital weather station are stored by computer in on-line mode.

  12. PV Systems Reliability Final Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.

  13. Terawatt Challenge for Thin-Film PV

    Energy Technology Data Exchange (ETDEWEB)

    Zweibel, K.

    2005-08-01

    The evolution of PV into one of the world's largest industries is not going to happen without major unforeseen problems. However, this study attempts to address the obvious ones, so that we can put aside the mythology of PV (for example, that it is only ''boutique power'' or that one must pave the world with it to be useful) and get on with changing the world's energy infrastructure. With the years of rapid market growth now under way in PV, the author is sure this will not be the last effort to understand the real potential and pitfalls of meeting the Challenge.

  14. PV panel model based on datasheet values

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2007-01-01

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....../panel in Standard Test Conditions (STC) are shown, as well as the parameters extraction from the data-sheet values. The temperature dependence of the cell dark saturation current is expressed with an alternative formula, which gives better correlation with the datasheet values of the power temperature dependence....... Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested....

  15. Scientific Opinion on the risk to plant health of Xanthomonas citri pv. citri and Xanthomonas citri pv. aurantifolii for the EU territory

    Directory of Open Access Journals (Sweden)

    EFSA Panel on Plant Health (PLH

    2014-02-01

    Full Text Available The Panel conducted a pest risk assessment for Xanthomonas campestris (all strains pathogenic to Citrus for the EU territory and an assessment of the effectiveness of present EU requirements against Xanthomonas strains pathogenic to citrus. The risk assessment was conducted under the scenario of absence of the current specific EU plant health legislation and the assumption that citrus-exporting countries apply measures to reduce yield and quality losses. Risk reduction options were systematically identified and evaluated. The strains of X. campestris pathogenic to citrus have been reclassified as four distinct infraspecific taxa within two species: X. citri and X. alfalfae. Only two pathovars (X. citri pv. citri and X. citri pv. aurantifolii are responsible for the citrus bacterial canker thatpresents a major risk for the citrus industry in the EU. Seven entry pathways have been identified and evaluated. The likelihood of entry was rated unlikely for fruit, very likely for fruit plants for planting, moderately likely for ornamental plants for planting and unlikely for leaves and twigs. The uncertainty of probability of entry was rated as high. The probability of establishment was rated as moderately likely to likely with a medium uncertainty because host plants are widely present in EU areas where environmental conditions are suitable. Once established, spread would be likely with a low uncertainty. The impact of the disease, even if control measures are applied, was rated as moderate to major with a medium uncertainty. The disease would cause yield losses in areas where citrus is the main crop, increase the need for control measures and create environmental problems.The combined EU regulations have been shown to be effective in preventing the introduction of X. citri pv. citri or X. citri pv. aurantifolii in the EU, as no outbreaks of citrus canker in the EU territory have been reported.

  16. Real time PV manufacturing diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Kochergin, Vladimir [MicroXact Inc., Blacksburg, VA (United States); Crawford, Michael A. [MicroXact Inc., Blacksburg, VA (United States)

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  17. Novel Methods to Determine Feeder Locational PV Hosting Capacity and PV Impact Signatures

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Coogan, Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Seuss, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    Often PV hosting capacity analysis is performed for a limited number of distribution feeders. For medium - voltage distribution feeders, previous results generally analyze less than 20 feeders, and then the results are extrapolated out to similar types of feeders. Previous hosting capacity research has often focused on determining a single value for the hosting capacity for the entire feeder, whereas this research expands previous hosting capacity work to investigate all the regions of the feeder that may allow many different hosting capacity values wit h an idea called locational hosting capacity (LHC)to determine the largest PV size that can be interconnected at different locations (buses) on the study feeders. This report discusses novel methods for analyzing PV interconnections with advanced simulati on methods. The focus is feeder and location - specific impacts of PV that determine the locational PV hosting capacity. Feeder PV impact signature are used to more precisely determine the local maximum hosting capacity of individual areas of the feeder. T he feeder signature provides improved interconnection screening with certain zones that show the risk of impact to the distribution feeder from PV interconnections.

  18. Seasonal energy storage - PV-hydrogen systems

    Energy Technology Data Exchange (ETDEWEB)

    Leppaenen, J. [Neste Oy/NAPS (Finland)

    1998-10-01

    PV systems are widely used in remote areas e.g. in telecommunication systems. Typically lead acid batteries are used as energy storage. In northern locations seasonal storage is needed, which however is too expensive and difficult to realise with batteries. Therefore, a PV- battery system with a diesel backup is sometimes used. The disadvantages of this kind of system for very remote applications are the need of maintenance and the need to supply the fuel. To overcome these problems, it has been suggested to use hydrogen technologies to make a closed loop autonomous energy storage system

  19. Updating Interconnection Screens for PV System Integration

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Mather, B.; Kroposki, B.; Lynn, K.; Razon, A.; Ellis, A.; Hill, R.; Key, T.; Nicole, K.; Smith, J.

    2012-02-01

    This white paper evaluates the origins and usefulness of the capacity penetration screen, offer short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen. Short-term and longer-term alternatives approaches are offered as examples; however, specific modifications to screening procedures should be discussed with stakeholders and must ultimately be adopted by state and federal regulatory bodies.

  20. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco;

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used t...... to track the MPP of the PV array, using the information that at MPP the power oscillations are very small. In this way the algorithm can detect the fact that the current working point is at the MPP, for the current atmospheric conditions....

  1. Large-Scale PV Integration Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Shuai; Etingov, Pavel V.; Diao, Ruisheng; Ma, Jian; Samaan, Nader A.; Makarov, Yuri V.; Guo, Xinxin; Hafen, Ryan P.; Jin, Chunlian; Kirkham, Harold; Shlatz, Eugene; Frantzis, Lisa; McClive, Timothy; Karlson, Gregory; Acharya, Dhruv; Ellis, Abraham; Stein, Joshua; Hansen, Clifford; Chadliev, Vladimir; Smart, Michael; Salgo, Richard; Sorensen, Rahn; Allen, Barbara; Idelchik, Boris

    2011-07-29

    This research effort evaluates the impact of large-scale photovoltaic (PV) and distributed generation (DG) output on NV Energy’s electric grid system in southern Nevada. It analyzes the ability of NV Energy’s generation to accommodate increasing amounts of utility-scale PV and DG, and the resulting cost of integrating variable renewable resources. The study was jointly funded by the United States Department of Energy and NV Energy, and conducted by a project team comprised of industry experts and research scientists from Navigant Consulting Inc., Sandia National Laboratories, Pacific Northwest National Laboratory and NV Energy.

  2. International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, J.; Kurtz, S.

    2014-10-01

    The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests are being developed for each of the selected climate zones.

  3. A Practical Irradiance Model for Bifacial PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-15

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors (CFs) to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using the RADIANCE ray tracing program.

  4. A Practical Irradiance Model for Bifacial PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-21

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using ray tracing software.

  5. Design optimization of grid-connected PV inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    The DC/AC inverters are the key elements in grid-connected PV energy production systems. In this paper, new design optimization techniques focused on transformerless (very high efficiency) PV inverters are proposed. They have been developed based on an analysis of the deficiencies of the current......, state-of-the-art PV inverters design technology, which limits the amount of PV energy supplied into the electric grid. The influences of the electric grid regulations and standards and the PV array operational characteristics on the design of grid-connected PV inverters have also been considered....... The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy injected into the electric grid by the optimized PV installation....

  6. On the Impact of Partial Shading on PV Output Power

    DEFF Research Database (Denmark)

    Sera, Dezso; Baghzouz, Yahia

    2008-01-01

    clarifies the mechanism of partial PV shading on a number of PV cells connected in series and/or parallel with and without bypass diodes. The analysis is presented in simple terms and can be useful to someone who wishes to determine the impact of some shading geometry on a PV system. The analysis...... is illustrated by measurements on a commercial 70 W panel, and a 14.4 kW PV array....

  7. Final Technical Report: PV Fault Detection Tool.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The PV Fault Detection Tool project plans to demonstrate that the FDT can (a) detect catastrophic and degradation faults and (b) identify the type of fault. This will be accomplished by collecting fault signatures using different instruments and integrating this information to establish a logical controller for detecting, diagnosing and classifying each fault.

  8. PV producers must advertise; Werbung wird wichtiger

    Energy Technology Data Exchange (ETDEWEB)

    Seltmann, T.

    2001-01-12

    Producers of current inverters are profiting from the growing PV market. The bigger suppliers are enhancing their advertising and marketing efforts while smaller suppliers opt for high-efficiency technology. [German] Vom kraeftigen Wachstum des Photovoltaik-Marktes profitieren zwangslaeufig auch die Wechselrichter-Hersteller. Die groesseren Anbieter verstaerken Vertrieb und Marketing, waehrend die kleineren versuchen, mit besonders effizienter Technik zu glaenzen. (orig.)

  9. Characterization of Xanthomonas axonopodis pv. phaseoli isolates

    NARCIS (Netherlands)

    Nunes, W.M.C.; Corazza, M.J.; De Souza, S.A.C.D.; Tsai, S.M.; Kuramae, E.E.

    2008-01-01

    A simple, quick and easy protocol was standardized for extraction of total DNA of the bacteria Xanthomonas axonopodis pv. phaseoli. The DNA obtained by this method had high quality and the quantity was enough for the Random Amplified Polymorphic DNA (RAPD) reactions with random primers, and

  10. Characterization of Xanthomonas axonopodis pv. phaseoli isolates

    NARCIS (Netherlands)

    Nunes, W.M.C.; Corazza, M.J.; De Souza, S.A.C.D.; Tsai, S.M.; Kuramae, E.E.

    2008-01-01

    A simple, quick and easy protocol was standardized for extraction of total DNA of the bacteria Xanthomonas axonopodis pv. phaseoli. The DNA obtained by this method had high quality and the quantity was enough for the Random Amplified Polymorphic DNA (RAPD) reactions with random primers, and Polymera

  11. PV-mooduli toodang suurfarmis / Teolan Tomson

    Index Scriptorium Estoniae

    Tomson, Teolan, 1932-

    2015-01-01

    Artiklis uuritakse PV-paneelide tootlikkuse langust nende vastastikuse varjutamise tõttu. Näidatakse, et Eesti oludes on soovitav kasutada paneelide madalaid kaldenurki ja suhtelist reavahet, mis ületab paneeli kõrguse pooleteistkordset väärtust

  12. TRNSYS HYBRID wind diesel PV simulator

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, P.J.A.; Mitchell, J.W.; Klein, S.A.; Beckman, W.A.; Blair, N.J. [Univ. of Wisconsin, Madison, WI (United States)

    1996-12-31

    The Solar Energy Laboratory (SEL) has developed a wind diesel PV hybrid systems simulator, UW-HYBRID 1.0, an application of the TRNSYS 14.2 time-series simulation environment. An AC/DC bus links up to five diesels and wind turbine models, along with PV modules, a battery bank, and an AC/DC converter. Multiple units can be selected. PV system simulations include solar angle and peak power tracking options. Weather data are Typical Meteorological Year data, parametrically generated synthesized data, or external data files. PV performance simulations rely on long-standing SEL-developed algorithms. Loads data are read as scalable time series. Diesel simulations include estimated fuel-use and waste heat output, and are dispatched using a least-cost of fuel strategy. Wind system simulations include varying air density, wind shear and wake effects. Time step duration is user-selectable. UW-HYBRID 1.0 runs in Windows{reg_sign}, with TRNSED providing a customizable user interface. 12 refs., 6 figs.

  13. PV-mooduli toodang suurfarmis / Teolan Tomson

    Index Scriptorium Estoniae

    Tomson, Teolan, 1932-

    2015-01-01

    Artiklis uuritakse PV-paneelide tootlikkuse langust nende vastastikuse varjutamise tõttu. Näidatakse, et Eesti oludes on soovitav kasutada paneelide madalaid kaldenurki ja suhtelist reavahet, mis ületab paneeli kõrguse pooleteistkordset väärtust

  14. A novel two-component response regulator links rpf with biofilm formation and virulence of Xanthomonas axonopodis pv. citri.

    Directory of Open Access Journals (Sweden)

    Tzu-Pi Huang

    Full Text Available Citrus bacterial canker caused by Xanthomonas axonopodis pv. citri is a serious disease that impacts citrus production worldwide, and X. axonopodis pv. citri is listed as a quarantine pest in certain countries. Biofilm formation is important for the successful development of a pathogenic relationship between various bacteria and their host(s. To understand the mechanisms of biofilm formation by X. axonopodis pv. citri strain XW19, the strain was subjected to transposon mutagenesis. One mutant with a mutation in a two-component response regulator gene that was deficient in biofilm formation on a polystyrene microplate was selected for further study. The protein was designated as BfdR for biofilm formation defective regulator. BfdR from strain XW19 shares 100% amino acid sequence identity with XAC1284 of X. axonopodis pv. citri strain 306 and 30-100% identity with two-component response regulators in various pathogens and environmental microorganisms. The bfdR mutant strain exhibited significantly decreased biofilm formation on the leaf surfaces of Mexican lime compared with the wild type strain. The bfdR mutant was also compromised in its ability to cause canker lesions. The wild-type phenotype was restored by providing pbfdR in trans in the bfdR mutant. Our data indicated that BfdR did not regulate the production of virulence-related extracellular enzymes including amylase, lipase, protease, and lecithinase or the expression of hrpG, rfbC, and katE; however, BfdR controlled the expression of rpfF in XVM2 medium, which mimics cytoplasmic fluids in planta. In conclusion, biofilm formation on leaf surfaces of citrus is important for canker development in X. axonopodis pv. citri XW19. The process is controlled by the two-component response regulator BfdR via regulation of rpfF, which is required for the biosynthesis of a diffusible signal factor.

  15. PV/T slates - Pilot project in Steinhausen; PV/T-Schiefer. Pilotprojekt Steinhausen

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report deals with a ventilated PV-tile system (PV/T-Slates) mounted on a garden shed in Steinhausen, Switzerland. The installation provides power and heat to the main house. The report describes the construction and operation of this pilot project and the results of measurements made on its electrical and thermal performance. The results of measurements made are presented in detail in graphical form and compared with the results of simulation. Suggestions are made for the optimisation of the system. Figures are presented on energy production and energy flows in graphical form.

  16. Commercialization of PV-powered pumping systems for use in utility PV service programs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project described in this report was a commercialization effort focused on cost-effective remote water pumping systems for use in utility-based photovoltaic (PV) service programs. The project combined a commercialization strategy tailored specifically for electric utilities with the development of a PV-powered pumping system that operates conventional ac pumps rather than relying on the more expensive and less reliable PV pumps on the market. By combining these two attributes, a project goal was established of creating sustained utility purchases of 250 PV-powered water pumping systems per year. The results of each of these tasks are presented in two parts contained in this Final Summary Report. The first part summarizes the results of the Photovoltaic Services Network (PSN) as a new business venture, while the second part summarizes the results of the Golden Photon system installations. Specifically, results and photographs from each of the system installations are presented in this latter part.

  17. Synergistic Activation of the Pathogenicity-Related Proline Iminopeptidase Gene in Xanthomonas campestris pv. campestris by HrpX and a LuxR Homolog

    OpenAIRE

    Zhang, Jingxi; Kan, Jinhong; Zhang, Jieqiong; Guo, Ping; Chen, Xiaoying; Fang, Rongxiang; Jia, Yantao

    2012-01-01

    Xanthomonas campestris pv. campestris strain 8004 contains an orphan quorum-sensing (QS) locus, xccR-pipXcc, in which the proline iminopeptidase (pipXcc) gene (where “Xcc” indicates that the pip gene is from X. campestris pv. campestris) is positively regulated by the LuxR homologue XccR by binding to the luxXc box of the pipXcc promoter. The disruption of pipXcc significantly attenuated the virulence of X. campestris pv. campestris. An imperfect plant-inducible promoter (PIP) box is located ...

  18. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module...

  19. The possibility of developing hybrid PV/T solar system

    Science.gov (United States)

    Dobrnjac, M.; Zivkovic, P.; Babic, V.

    2017-05-01

    An alternative and cost-effective solution to developing integrated PV system is to use hybrid photovoltaic/thermal (PV/T) solar system. The temperature of PV modules increases due to the absorbed solar radiation that is not converted into electricity, causing a decrease in their efficiency. In hybrid PV/T solar systems the reduction of PV module temperature can be combined with a useful fluid heating. In this paper we present the possibility of developing a new hybrid PV/T solar system. Hybrid PV/T system can provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation. We developed PV/T prototype consisted of commercial PV module and thermal panel with our original solution of aluminium absorber with special geometric shapes. The main advantages of our combined PV/T system are: removing of heat from the PV panel; extending the lifetime of photovoltaic cells; excess of the removing heat from PV part is used to heat the fluid in the thermal part of the panel; the possibility of using on the roof and facade constructions because less weight.

  20. High Resolution PV Power Modeling for Distribution Circuit Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  1. Determination of Parameters of PV Concentrating System With Heliostat

    Science.gov (United States)

    Vardanyan, R.; Norsoyan, A.; Dallakyan, V.

    2010-10-01

    The structure of PV concentrating system with heliostat is analyzed. The mathematical model of system consisting of PV concentrating module and heliostat is developed. With the use of developed mathematical model the optimal parameters of the system are determined. The results of this work can be used during the design of PV concentrating systems with heliostats.

  2. Assessing the need for better forecasting and observability of pv

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Efthymiou, Venizelos; Graditi, Giorgio

    2017-01-01

    In its review of the challenges and opportunities associated with massive deployment of solar PV generation, the Grid integration working group of the ETIP PV identified forecasting and observability as critical technologies for the planning and operation of the power system with large PV penetra...

  3. Beacons In Brief. P/PV In Brief. Issue 2

    Science.gov (United States)

    Blank, Susan; Farley, Chelsea

    2004-01-01

    This second issue in P/PV's "In Brief" series focuses on the San Francisco Beacon Initiative and P/PV's recently released evaluation results. The Beacon Initiative established after-school programs in eight public schools in low-income San Francisco neighborhoods. P/PV's 36-month evaluation examined key developmental and academic outcomes.…

  4. Evaluation of triticale accessions for resistance to wheat bacterial leaf streak caused by Xanthomonas translucens pv. undulosa

    Science.gov (United States)

    The bacterium Xanthomonas translucens pv. undulosa (Xtu) causes bacterial leaf streak (BLS) on wheat and other small grains. Several triticale accessions were reported to possess high levels of resistance to wheat Xtu strains. In this study, we evaluated a worldwide collection of 502 triticale acces...

  5. A rapid seedling resistance assay identifies wild tomato lines that are resistant to Psuedomonas syringe pv. tomato race 1

    Science.gov (United States)

    Bacterial speck caused by Pseudomonas syringae has historically been controlled by the Pto/Prf gene cluster. Emerging strains like P. syringae pv. tomato race 1 overcome resistance conferred by Pto/Prf, and can cause serious crop loss under appropriate environmental conditions. We developed a rapid ...

  6. Natural acquired inhibitory antibodies to Plasmodium vivax Duffy binding protein (PvDBP-II) equally block erythrocyte binding of homologous and heterologous expressed PvDBP-II on the surface of COS-7 cells.

    Science.gov (United States)

    Valizadeh, Vahideh; Zakeri, Sedigheh; Mehrizi, Akram A; Mirkazemi, Sedigheh; Djadid, Navid D

    2016-02-01

    The binding domain of Plasmodium vivax Duffy binding protein (PvDBP-II) is a promising blood-stage vaccine candidate for vivax malaria. For the development of a successful vivax malaria vaccine based on DBP-II, the antigenic diversity and also naturally occurring functional antibodies to different PvDBP-II variant types in the various populations must be determined. However, similar to other blood-stage antigens, allelic variation within the PvDBP-II is a fundamental challenge for the development of a broadly efficient vaccine. The present study was performed to define whether the polymorphisms in PvDBP-II influence the nature of functional inhibitory activity of naturally acquired or induced anti-DBP-II antibodies in mice. In this investigation, five genetically distinct variants of PvDBP-II were transiently expressed on the COS-7 cell surface. Erythrocyte-binding inhibition assay (EBIA) was performed using human sera infected with corresponding and non-corresponding P. vivax variants as well as by the use of mice sera immunized with different expressed recombinant PvDBP-IIs. EBIA results showed that the inhibitory percentage varied between 50 and 63 % by using sera from infected individuals, and in case of mouse antisera, inhibition was in the range of 76-86 %. Interestingly, no significant difference was detected in red blood cell binding inhibition when different PvDBP-II variants on the COS-7 cell surfaces were incubated with heterologous and homologous sera infected with PvDBP-II variants. This suggests that the detected polymorphisms in all five forms of PvDBP-II may not affect functional activity of anti-DBP-II antibodies. In conclusion, our results revealed that there are functional cross-reactive antibody responses to heterologous PvDBP-II variants that might provide a broader inhibitory response against all, or at least the majority of strains compared to single allele of this protein that should be considered in development of PvDBP-II-based vaccine.

  7. 水稻白叶枯病菌GX1329基因组文库的构建及含编码TAL效应物基因的克隆的分离%Construction of a Genomic Library of Xanthomonas oryzae pv. oryzae Strain GX1329 and Isolation of Clones Containing the Genes Encoding TAL Ef- fectors

    Institute of Scientific and Technical Information of China (English)

    张子宇; 赵帅; 莫伟兰; 罗雪梅; 玉延华; 段承杰; 冯家勋

    2011-01-01

    由革兰氏阴性细菌水稻白叶枯病菌引起的水稻白叶枯病是亚洲、北美以及非洲部分地区最严重的水稻病害之一,水稻白叶枯病可使水稻减产高达50%以上。研究表明水稻白叶枯病菌的毒力主要依靠三型分泌系统所分泌的效应物。为了解水稻白叶枯病菌广西菌株GX1329中含有avrBs3/pthA家族基因的情况,本研究应用Alu I部分酶切其基因组DNA,构建了含有736个克隆的菌株GX1329的基因组文库。BamHI酶切分析随机挑取的15个文库克隆表明,克隆的外源DNA随机性良好,克隆的最小片段为27.7kb,最大为58.5kb,平均大小为39.9kb,文库克隆容量约为2.8×10^3Mb,该文库中包含基因组中任一个基因的概率为99.4%。利用来自水稻白叶枯病菌菲律宾菌株PX086的无毒基因avrXa10的第252位~第486位核苷酸序列作为探针,通过菌落原位杂交从GX1329基因组文库中筛选到37个含avrBs3/pthA家族基因的克隆。再通过Southern杂交分析,得到了17个独立克隆。这17个克隆中至少含有13个不同的avrBs3/pthA家族基因。这些基因在GX1329基因组中有的单独存在,有的两个或两个以上串联存在。本工作基本上明确了菌株GX1329基因组中avrBs3/pthA家族基因的数量,为进一步研究菌株GX1329中avrBs3/pthA家族基因的功能奠定了基础。%Bacterial leaf blight (BLB), caused by Gram-negative bacterium Xanthomonas oryzae pv. oryzae (Xoo), is a serious threat to yield losses in the main regions of rice growth including Asia, North America and Africa. BLB could lead to a crop loss of up to 50%. It is known that the virulence of Xoo mainly relies on type BI secre- tion system (T3SS) and its secreted effectors. To know the numbers of genes encoding avrBs3/pthA family mem- bers in Guangxi Xoo strain GX1329, a genomic DNA library containing 736 clones was successfully constructed by partially

  8. 水稻白叶枯病菌GX1329基因组文库的构建及含编码TAL效应物基因的克隆的分离%Construction of a Genomic Library of Xanthomonas oryzae pv.oryzae Strain GX1329 and Isolation of Clones Containing the Genes Encoding TAL Effectors

    Institute of Scientific and Technical Information of China (English)

    张子宇; 赵帅; 莫伟兰; 罗雪梅; 玉延华; 段承杰; 冯家勋

    2011-01-01

    Bacterial leaf blight (BLB), caused by Gram-negative bacterium Xanthomonas oryzae pv. oryzae (Xoo),is a serious threat to yield losses in the main regions of rice growth including Asia, North America and Africa.BLB could lead to a crop loss of up to 50%. It is known that the virulence of Xoo mainly relies on type Ⅲ secretion system (T3SS) and its secreted effectors. To know the numbers of genes encoding avrBs3/pthA family members in Guangxi Xoo strain GX1329, a genomic DNA library containing 736 clones was successfully constructed by partially digesting the genomic DNA with A lu Ⅰ . Restriction enzyme BamH Ⅰ digestion analysis of plasmids from 15 randomly chosen library clones showed that the cloned DNA in the genomic library was highly random.The size of the smallest cloned DNA in one clone was 27.7kb, the size of the biggest cloned DNA in one clone was 58.5 kb, and the average size of cloned DNA in one clone was 39.9 kb. The cloning capacity of the library is about 2.8x103 Mb with high randomness, and the probability of any one gene contained in the library was about 99.4%.Thirty-seven positive clones were screened out from the GX1329 genomic library by colony in situ hybridization using the 252th to 486th bp sequence of avrXa10 from Xoo strain PXO86 as probe. Southern hybridization analysis of the 17 clones showed that they contain at least 13 different avrBs3/pthA genes. The results also showed that the avrB.s3/pthA family genes occurred in individual or clusters in the genome of strain GX1329. This work defined the number of avrBs3/pthA family genes in the genome of GX1329, which may provide a solid basis for further studying the function of the genes.%由革兰氏阴性细菌水稻白叶枯病菌引起的水稻白叶枯病是亚洲、北美以及非洲部分地区最严重的水稻病害之一,水稻白叶枯病可使水稻减产高达50%以上.研究表明水稻白叶枯病菌的毒力主要依靠三型分泌系统所分泌的效应物.为了解

  9. Technologies to Increase PV Hosting Capacity in Distribution Feeders: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-08-01

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  10. Remote and Centralized Monitoring of PV Power Plants

    DEFF Research Database (Denmark)

    Kopacz, Csaba; Spataru, Sergiu; Sera, Dezso

    2014-01-01

    the inverters within each PV plant. The monitoring software stores the PV measurements in a data warehouse optimized for managing and data mining large amounts of data, from where it can be later visualized, analyzed and exported. By combining PV production measurements data with I-V curve measurements......This paper presents the concept and operating principles of a low-cost and flexible monitoring system for PV plants. Compared to classical solutions which can require dedicated hardware and/or specialized data logging systems, the monitoring system we propose allows parallel monitoring of PV plants...

  11. PV_LIB Toolbox v. 1.3

    Energy Technology Data Exchange (ETDEWEB)

    2015-12-09

    PV_LIB comprises a library of Matlab? code for modeling photovoltaic (PV) systems. Included are functions to compute solar position and to estimate irradiance in the PV system’s plane of array, cell temperature, PV module electrical output, and conversion from DC to AC power. Also included are functions that aid in determining parameters for module performance models from module characterization testing. PV_LIB is open source code primarily intended for research and academic purposes. All algorithms are documented in openly available literature with the appropriate references included in comments within the code.

  12. On Distributed PV Hosting Capacity Estimation, Sensitivity Study, and Improvement

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry

    2017-07-01

    This paper first studies the estimated distributed PV hosting capacities of seventeen utility distribution feeders using the Monte Carlo simulation based stochastic analysis, and then analyzes the sensitivity of PV hosting capacity to both feeder and photovoltaic system characteristics. Furthermore, an active distribution network management approach is proposed to maximize PV hosting capacity by optimally switching capacitors, adjusting voltage regulator taps, managing controllable branch switches and controlling smart PV inverters. The approach is formulated as a mixed-integer nonlinear optimization problem and a genetic algorithm is developed to obtain the solution. Multiple simulation cases are studied and the effectiveness of the proposed approach on increasing PV hosting capacity is demonstrated.

  13. Technologies to Increase PV Hosting Capacity in Distribution Feeders

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-11-14

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  14. Voltage rise mitigation for solar PV integration at LV grids

    DEFF Research Database (Denmark)

    Yang, Guangya; Marra, Francesco; Juamperez Goñi, Miguel Angel

    2015-01-01

    Solar energy from photovoltaic (PV) is among the fastest developing renewable energy systems worldwide. Driven by governmental subsidies and technological development, Europe has seen a fast expansion of solar PV in the last few years. Among the installed PV plants, most of them are situated...... at the distribution systems and bring various operational challenges such as power quality and power flow management. The paper discusses the modelling requirements for PV system integration studies, as well as the possible techniques for voltage rise mitigation at low voltage (LV) grids for increasing PV penetration...

  15. Fate of a Pseudomonas savastanoi pv. savastanoi type III secretion system mutant in olive plants (Olea europaea L.).

    Science.gov (United States)

    Pérez-Martínez, Isabel; Rodríguez-Moreno, Luis; Lambertsen, Lotte; Matas, Isabel M; Murillo, Jesús; Tegli, Stefania; Jiménez, Antonio J; Ramos, Cayo

    2010-06-01

    Pseudomonas savastanoi pv. savastanoi strain NCPPB 3335 is a model bacterial pathogen for studying the molecular basis of disease production in woody hosts. We report the sequencing of the hrpS-to-hrpZ region of NCPPB 3335, which has allowed us to determine the phylogenetic position of this pathogen with respect to previously sequenced Pseudomonas syringae hrp clusters. In addition, we constructed a mutant of NCPPB 3335, termed T3, which carries a deletion from the 3' end of the hrpS gene to the 5' end of the hrpZ operon. Despite its inability to multiply in olive tissues and to induce tumor formation in woody olive plants, P. savastanoi pv. savastanoi T3 can induce knot formation on young micropropagated olive plants. However, the necrosis and formation of internal open cavities previously reported in knots induced by the wild-type strain were not observed in those induced by P. savastanoi pv. savastanoi T3. Tagging of P. savastanoi pv. savastanoi T3 with green fluorescent protein (GFP) allowed real-time monitoring of its behavior on olive plants. In olive plant tissues, the wild-type strain formed aggregates that colonized the intercellular spaces and internal cavities of the hypertrophic knots, while the mutant T3 strain showed a disorganized distribution within the parenchyma of the knot. Ultrastructural analysis of knot sections revealed the release of extensive outer membrane vesicles from the bacterial cell surface of the P. savastanoi pv. savastanoi T3 mutant, while the wild-type strain exhibited very few vesicles. This phenomenon has not been described before for any other bacterial phytopathogen during host infection.

  16. The Comprehensive Study of Electrical Faults in PV Arrays

    Directory of Open Access Journals (Sweden)

    M. Sabbaghpur Arani

    2016-01-01

    Full Text Available The rapid growth of the solar industry over the past several years has expanded the significance of photovoltaic (PV systems. Fault analysis in solar photovoltaic (PV arrays is a fundamental task to increase reliability, efficiency, and safety in PV systems and, if not detected, may not only reduce power generation and accelerated system aging but also threaten the availability of the whole system. Due to the current-limiting nature and nonlinear output characteristics of PV arrays, faults in PV arrays may not be detected. In this paper, all possible faults that happen in the PV system have been classified and six common faults (shading condition, open-circuit fault, degradation fault, line-to-line fault, bypass diode fault, and bridging fault have been implemented in 7.5 KW PV farm. Based on the simulation results, both normal operational curves and fault curves have been compared.

  17. Optimal Design of Modern Transformerless PV Inverter Topologies

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during...... the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inverter design variables are derived for each PV inverter topology and installation site. The H5, H6, neutral point...... clamped, active-neutral point clamped and conergy-NPC PV inverters designed using the proposed optimization process feature lower levelized cost of generated electricity and lifetime cost, longer mean time between failures and inject more PV-generated energy into the electric grid than their nonoptimized...

  18. Plasmodium vivax merozoite surface protein-3 (PvMSP3: expression of an 11 member multigene family in blood-stage parasites.

    Directory of Open Access Journals (Sweden)

    Jianlin Jiang

    Full Text Available BACKGROUND: Three members of the Plasmodium vivax merozoite surface protein-3 (PvMSP3 family (PvMSP3-α, PvMSP3-β and PvMSP3-γ were initially characterized and later shown to be part of a larger highly diverse family, encoded by a cluster of genes arranged head-to-tail in chromosome 10. PvMSP3-α and PvMSP3-β have become genetic markers in epidemiological studies, and are being evaluated as vaccine candidates. This research investigates the gene and protein expression of the entire family and pertinent implications. METHODOLOGY/PRINCIPAL FINDINGS: A 60 kb multigene locus from chromosome 10 in P. vivax (Salvador 1 strain was studied to classify the number of pvmsp3 genes present, and compare their transcription, translation and protein localization patterns during blood-stage development. Eleven pvmsp3 paralogs encode an N-terminal NLRNG signature motif, a central domain containing repeated variable heptad sequences, and conserved hydrophilic C-terminal features. One additional ORF in the locus lacks these features and was excluded as a member of the family. Transcripts representing all eleven pvmsp3 genes were detected in trophozoite- and schizont-stage RNA. Quantitative immunoblots using schizont-stage extracts and antibodies specific for each PvMSP3 protein demonstrated that all but PvMSP3.11 could be detected. Homologs were also detected by immunoblot in the closely related simian species, P. cynomolgi and P. knowlesi. Immunofluorescence assays confirmed that eight of the PvMSP3s are present in mature schizonts. Uniquely, PvMSP3.7 was expressed exclusively at the apical end of merozoites. CONCLUSION/SIGNIFICANCE: Specific proteins were detected representing the expression of 10 out of 11 genes confirmed as members of the pvmsp3 family. Eight PvMSP3s were visualized surrounding merozoites. In contrast, PvMSP3.7 was detected at the apical end of the merozoites. Pvmsp3.11 transcripts were present, though no corresponding protein was detected

  19. Development of a dispatchable PV peak shaving system. Final report on PV:BONUS Phase 2 activities

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, W.D. [Conectiv, Inc., Wilmington, DE (United States); Nigro, R.M. [Applied Energy Group, Inc., Hauppauge, NY (United States)

    1999-01-20

    In July 1993, the Delmarva Power and Light Company (now Conectiv, Inc.) was awarded a contract for the development of a Dispatchable Photovoltaic Peak Shaving System under the US Department of Energy PV:BONUS Program. The rationale for the dispatchable PV peak shaving system is based on the coincidence between the solar resource and the electrical load in question. Where poor coincidence exists, a PV array by itself does little to offset peak demands. However, with the addition of a relatively small amount of energy storage, the energy from the PV array can be managed and the value of the PV system increases substantially. In Phase 2, Delmarva Power continued the refinement of the system deployed in Phase 1. Four additional dispatchable PV peak shaving systems were installed for extended testing and evaluation at sites in Delaware, Maryland, Wisconsin and North Carolina. A second type of system that can be used to provide back-up power as well as peak shaving was also developed in Phase 2. This PV-UPS system used a packaging approach nearly identical to the PV peak shaving system, although there were significant differences in the design of the power electronics and control systems. Conceptually, the PV-UPS system builds upon the idea of adding value to PV systems by increasing functionality. A prototype of the PV-UPS system was installed in Delaware for evaluation near the end of the contract period.

  20. Response to Xanthomonas campestris pv. vesicatoria in tomato involves regulation of ethylene receptor gene expression.

    Science.gov (United States)

    Ciardi, J A; Tieman, D M; Lund, S T; Jones, J B; Stall, R E; Klee, H J

    2000-05-01

    Although ethylene regulates a wide range of defense-related genes, its role in plant defense varies greatly among different plant-microbe interactions. We compared ethylene's role in plant response to virulent and avirulent strains of Xanthomonas campestris pv. vesicatoria in tomato (Lycopersicon esculentum Mill.). The ethylene-insensitive Never ripe (Nr) mutant displays increased tolerance to the virulent strain, while maintaining resistance to the avirulent strain. Expression of the ethylene receptor genes NR and LeETR4 was induced by infection with both virulent and avirulent strains; however, the induction of LeETR4 expression by the avirulent strain was blocked in the Nr mutant. To determine whether ethylene receptor levels affect symptom development, transgenic plants overexpressing a wild-type NR cDNA were infected with virulent X. campestris pv. vesicatoria. Like the Nr mutant, the NR overexpressors displayed greatly reduced necrosis in response to this pathogen. NR overexpression also reduced ethylene sensitivity in seedlings and mature plants, indicating that, like LeETR4, this receptor is a negative regulator of ethylene response. Therefore, pathogen-induced increases in ethylene receptors may limit the spread of necrosis by reducing ethylene sensitivity.

  1. Energy balance of the global photovoltaic (PV) industry--is the PV industry a net electricity producer?

    Science.gov (United States)

    Dale, Michael; Benson, Sally M

    2013-04-02

    A combination of declining costs and policy measures motivated by greenhouse gas (GHG) emissions reduction and energy security have driven rapid growth in the global installed capacity of solar photovoltaics (PV). This paper develops a number of unique data sets, namely the following: calculation of distribution of global capacity factor for PV deployment; meta-analysis of energy consumption in PV system manufacture and deployment; and documentation of reduction in energetic costs of PV system production. These data are used as input into a new net energy analysis of the global PV industry, as opposed to device level analysis. In addition, the paper introduces a new concept: a model tracking energetic costs of manufacturing and installing PV systems, including balance of system (BOS) components. The model is used to forecast electrical energy requirements to scale up the PV industry and determine the electricity balance of the global PV industry to 2020. Results suggest that the industry was a net consumer of electricity as recently as 2010. However, there is a >50% that in 2012 the PV industry is a net electricity provider and will "pay back" the electrical energy required for its early growth before 2020. Further reducing energetic costs of PV deployment will enable more rapid growth of the PV industry. There is also great potential to increase the capacity factor of PV deployment. These conclusions have a number of implications for R&D and deployment, including the following: monitoring of the energy embodied within PV systems; designing more efficient and durable systems; and deploying PV systems in locations that will achieve high capacity factors.

  2. An Analysis of Open World PvP in LOTRO's PvMP as a Case Study for PvP Games

    Directory of Open Access Journals (Sweden)

    Toh Weimin

    2014-11-01

    Full Text Available This article focuses on the analysis of emergent gameplay, based on a case study of the author's subjective gameplay experience of Player versus Monster Player (PvMP in The Lord of the Rings Online (LOTRO. The argument presented here is that although there is a core system of Player versus Player (PvP which LOTRO shares with other online games, each type of online game has a specific kind of PvP system which attracts players to engage in the gameplay. For instance, the open world sandbox type of PvP attracts certain players to play in LOTRO's PvMP. One of the main aims of this study is thus to investigate some of the core systems of PvP gameplay in open world sandbox PvP. In this article, LOTRO is shown to offer unique opportunities for studying emergent gameplay in open world games, with particular relevance to PvP studies. Two of the core systems of PvP discussed include the design of the simple gameplay rules to support emergent gameplay, and the community's attitudes towards player's behaviours. The types of emergent gameplay discussed include free play versus negotiated fair play, the players' utilisation of strategies in open world PvP to support collaborative and competitive gameplay, and the changing dynamics of open ended gameplay. It is hoped that the analysis provided in this article would form the­ basis of future work on a more general framework for understanding PvP in other online games.

  3. [Cloning, sequencing and fuctional study of gacA gene from Xanthomonas oryzae pv. oryzicola].

    Science.gov (United States)

    Yang, Wan-feng; Chen, Lei; Liu, Hong-xia; Hu, Bai-shi; Liu, Feng-quan

    2007-04-01

    A gacA homologue, designated gacA(Xooc), was cloned from Xanthomonas oryzae pv. oryzicola (Xooc), a bacterium that causes leaf streak of rice, with degenerated primers by polymerase amplification reaction (PCR). NCBI blast search indicated that GacA(Xooc) had a similar structure to that of other GacA proteins, and had a CheB (Chemotaxis response regulator containing a CheY-like receiver domain)domain. Sequence comparison showed that the gacA(Xooc) was conserved in the Xanthomonas genus. Homology search revealed that the gacA(Xooc) was 99.7% similarities to gacA (AY870457, this lab) of Xanthomonas oryzae pv. oryzae (Xoo). A gacA(Xooc), disruption mutant was successfully generated by a single cross-over event, and confirmed by PCR and Southern blot. But the mutant still had strong pathogenicity,and its virulence was not obviously different from that of wild type strain. The gacA did not globally regulate metabolism in Xooc, which was different from DC3000 of P. syringae pv. tomato, CHAO of P. fluorescens and IC1270 of Serratia plymuthica. Chemotaxis to 0.1% tryptone of the mutants was reduced compared to wild type strain. The results suggest that gacA(X00c) is involved chemotaxis of Xooc. Nevertheless, how gacA to regulate chemotaxis of Xooc, transcription and expression of genes involved in regulation still need to be further studied.

  4. Numerical study of PV/T-SAHP system

    Institute of Scientific and Technical Information of China (English)

    Gang PEI; Jie JI; Ke-liang LIU; Han-feng HE; Ai-guo JIANG

    2008-01-01

    In order to utilize solar energy effectively and to achieve a higher electrical efficiency by limiting the operating temperature of the photovoltaic (PV) panel, a novel photovoltaic/thermal solar-assisted heat pump (PV/T-SAHP) system was proposed and constructed. The hybrid solar system generates electricity and thermal energy simultaneously. A distributed parameters model of the PV/T-SAHP system was developed and applied to analyze the system dynamic performance in terms of PV action, photothermal action and Rankine cycle processes. The simulation results indicated that the coefficient of performance (COP) of the proposed PV/T-SAHP can be much better than that of the conventional heat pump. Both PV-efficiency and photothermic efficiency have been improved considerably. The results also showed that the performance of this PV/T-SAHP system was strongly influenced by the evaporator area, tube pitch and tilt angle of the PV/T evaporator, which are the key factors in PV/T-SAHP system optimization and PV/T evaporator design.

  5. Pseudomonas syringae pv. phaseolicola isolated from weeds in bean crop fields.

    Science.gov (United States)

    Fernández-Sanz, A M; Rodicio, M R; González, A J

    2016-04-01

    Pseudomonas syringae pv. phaseolicola, the causative agent of halo blight in common bean (Phaseolus vulgaris L.), was isolated from weeds associated with bean crops in Spain. The bacterium was recovered from Fumaria sp, Mercurialis annua, Solanum nigrum and Sonchus oleraceus. Ps. s. pv. phaseolicola had previously been isolated from leguminous plants and S. nigrum, but to our knowledge, this is the first time it was recovered from the other three species. The isolates were phenotypically and genetically characterized, and they were compared with isolates recovered from common beans. Five different genotypic profiles were detected by PmeI-PFGE, two of them being of new description. Weed isolates were as pathogenic on bean plants as bean isolates, but they were not pathogenic on S. nigrum. Regarding the survival of the pathogen in weeds, Ps. s. pv. phaseolicola was isolated from So. oleraceus 11 weeks after the end of the bean crop. These results strongly support the idea of weeds as a potential source of inoculum for halo blight in bean. It has traditionally been considered that the main source of inoculum of Pseudomonas syringae pv. phaseolicola causing halo blight disease in Phaseolus vulgaris are the bean seeds, and that the host range of the bacterium is almost restricted to leguminous plants. In this study, the bacterium was recovered from four nonleguminous weed species collected in bean fields, and its permanence in weeds for at least 11 weeks after the harvesting of the beans was demonstrated. We have also proved that the strains isolated from weeds were pathogenic on bean plants. Accordingly, the host range of Ps. s. pv. phaseolicola could be broader than previously thought and weeds appear to be acting as a reservoir of the pathogen until the next crop. © 2016 The Society for Applied Microbiology.

  6. PV solar electricity: status and future

    Science.gov (United States)

    Hoffmann, Winfried

    2006-04-01

    Within the four main market segments of PV solar electricity there are already three areas competitive today. These are off-grid industrial and rural as well as consumer applications. The overall growth within the past 8 years was almost 40 % p.a. with a "normal" growth of about 18 % p.a. for the first three market segments whereas the grid connected market increased with an astonishing 63 % p.a. The different growth rates catapulted the contribution of grid connected systems in relation to the total market from about one quarter 6 years ago towards more than three quarters today. The reason for this development is basically due to industry-politically induced market support programs in the aforementioned countries. It is quite important to outline under which boundary conditions grid connected systems will be competitive without support programs like the feed in tariff system in Germany, Spain and some more to come in Europe as well as investment subsidies in Japan, US and some other countries. It will be shown that in a more and more liberalized utility market worldwide electricity produced by PV solar electricity systems will be able to compete with their generating cost against peak power prices from utilities. The point of time for this competitiveness is mainly determined by the following facts: 1. Price decrease for PV solar electricity systems leading to an equivalent decrease in the generated cost for PV produced kWh. 2. Development of a truly liberalized electricity market. 3. Degree of irradiation between times of peak power demand and delivery of PV electricity. The first topic is discussed using price experience curves. Some explanations will be given to correlate the qualitative number of 20 % price decrease for doubling cumulative worldwide sales derived from the historic price experience curve with a more quantitative analysis based on our EPIA-Roadmap (productivity increase and ongoing improvements for existing technologies as well as development

  7. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T) system against conventional photovoltaic (PV) system

    OpenAIRE

    2015-01-01

    Photovoltaic (PV) semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T) panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the...

  8. PV/T slates - Application examples and case studies; PV/T-Schiefer. Anwendungsbeispiele und Fallstudien

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report presents possible applications for PV/T slates based on data from the production atlas presented in another report in this series. Application variants are discussed, including hot-water preparation, air pre-heating, air-water heat pumps, buried seasonal storage and latent seasonal heat storage. Detailed examples are given for a hotel in Lugano, Switzerland and a residential estate in Davos.

  9. PV shading device integrated system in a University Building in Italy

    OpenAIRE

    2004-01-01

    PV Enlargement project PV Enlargement" boldly demonstrates Europe’s commitment for improved energy efficiency and cost-effectiveness of PV systems, enhancing the development of large European PV markets. The project can be subdivided into three major fields of activities: Demonstration (1,218 kWp) of highly cost-effective or very innovative PV technologies in 10 European countries for increasing public awareness about and visibility of PV solar electricity Transfer of PV Technol...

  10. PV/T slates - Production atlas; PV/T-Schiefer. Ertragsatlas

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report first deals with the dynamic building simulation system IDA and goes on to present an appendix that lists the results for the three climatic locations Zurich, Lugano and Davos in detail. The results are calculated for various seasons, orientations, mounting angles, air-flow rates and temperature differences.

  11. Testing to Support Improvements to PV Components and Systems

    Energy Technology Data Exchange (ETDEWEB)

    THOMAS,H.; KROPOSKI,B.; WITT,C.; BOWER,WARD I.; BONN,RUSSELL H.; GINN,JERRY W.; GONZALEZ,SIGIFREDO

    2000-07-15

    The National Photovoltaic (PV) Program is sponsored by the US Department of Energy and includes a PV Manufacturing Research and Development (R and D) project conducted with industry. This project includes advancements in PV components to improve reliability, reduce costs, and develop integrated PV systems. Participants submit prototypes, pre-production hardware products, and examples of the resulting final products for a range of tests conducted at several national laboratories, independent testing laboratories, and recognized listing agencies. The purpose of this testing is to use the results to assist industry in determining a product's performance and reliability, and to identify areas for potential improvement. This paper briefly describes the PV Manufacturing R and D project, participants in the area of PV systems, balance of systems, and components, and several examples of the different types of product and performance testing used to support and confirm product performance.

  12. PV technology and success of solar electricity in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Dung, T.Q. [Vietnam National Center for Science and Technology, Ho Chi Minh City (Viet Nam). Solarlab

    1997-12-31

    Since 1990 the PV Technology and the Solar electricity have been strongly developed in Vietnam. The PV experts of Solarlab have studied and set up an appropriate PV Technology responding to local Market needs. It has not only stood well but has been also transferred to Mali Republic and Lao P.D.R. The PV off grid systems of Solarlab demonstrate good efficiency and low prices. Over 60 solar stations and villages have been built to provide solar lighting for about 3000 families along the country in remote, mountainous areas and islands. 400 families are using stand-alone Solar Home Systems. The Solar electricity has been chosen for Rural Electrification and National Telecommunication Network in remote and mountainous regions. Many International projects in cooperation with FONDEM-France, SELF USA and Governmental PV projects have been realized by Solarlab. The experiences of maintenance, management and finance about PV development in Vietnam are also mentioned.

  13. Genome sequence and rapid evolution of the rice pathogen Xanthomonas oryzae pv. oryzae PXO99A

    Directory of Open Access Journals (Sweden)

    Szurek Boris

    2008-05-01

    Full Text Available Abstract Background Xanthomonas oryzae pv. oryzae causes bacterial blight of rice (Oryza sativa L., a major disease that constrains production of this staple crop in many parts of the world. We report here on the complete genome sequence of strain PXO99A and its comparison to two previously sequenced strains, KACC10331 and MAFF311018, which are highly similar to one another. Results The PXO99A genome is a single circular chromosome of 5,240,075 bp, considerably longer than the genomes of the other strains (4,941,439 bp and 4,940,217 bp, respectively, and it contains 5083 protein-coding genes, including 87 not found in KACC10331 or MAFF311018. PXO99A contains a greater number of virulence-associated transcription activator-like effector genes and has at least ten major chromosomal rearrangements relative to KACC10331 and MAFF311018. PXO99A contains numerous copies of diverse insertion sequence elements, members of which are associated with 7 out of 10 of the major rearrangements. A rapidly-evolving CRISPR (clustered regularly interspersed short palindromic repeats region contains evidence of dozens of phage infections unique to the PXO99A lineage. PXO99A also contains a unique, near-perfect tandem repeat of 212 kilobases close to the replication terminus. Conclusion Our results provide striking evidence of genome plasticity and rapid evolution within Xanthomonas oryzae pv. oryzae. The comparisons point to sources of genomic variation and candidates for strain-specific adaptations of this pathogen that help to explain the extraordinary diversity of Xanthomonas oryzae pv. oryzae genotypes and races that have been isolated from around the world.

  14. PV window - Development and demonstrations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haugaard, P.

    2011-05-15

    Using the results from the EU project RenewTransnet, which focused on the development of a pane with integrated solar cells, the goal of this project is to develop these principles into a window solution. This window solution is targeted to Danish building tradition and architecture. It is expected that an elegant PV-window solution for both new and retrofit buildings is developed during this project, and which appearance can be customized to each building. Based on results from a related projects carried out by Gaia Solar, the window solution will have the potential of being approximately 30% cheaper than similar products on the market. In this project this price reduction is the objective of the development of a window solution. The project team has succeeded in developing a 2-layer PV-window with glass / glass lamination with EVA as foil, which is 35% cheaper than similar products on the market. Since the price for the frame-profile does not differ significantly at market level, the price comparison is made on the basis of the developed PV-pane. The objective of 30 % price reduction in relation to similar products on the market is met. A special production process to the making glass/glass lamination with EVA as foil has been developed, in which a frame is put around the module which intends both to remove the unwanted tension along the edges, and to prevent the significant spillage of EVA from the module under pressure and prevent the invasive bubbles along the edge of module. Since the developed production method for making glass/glass modules with EVA is simple, a further cost reduction will primarily be in a reduction of the price of the cell. The project process has resulted in the development of a product, which due to continuous restrictions in the building regulations, will be very attractive in future buildings. (LN)

  15. PV modules without bypass diodes; PV-Module ohne Bypass-Dioden? - Untersuchungen an einer PV-Fassade

    Energy Technology Data Exchange (ETDEWEB)

    Laukamp, H.; Kresse, A.; Leithold, W. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany)]|[Ingenieurbuero A. Kresse, Karlsruhe (Germany)]|[Solare Systemtechnik GmbH, Freiburg (Germany)

    1998-12-01

    In order to protect solar modules against high output losses with non-homogeneous irradiation, bypass diodes which are mostly accommodated in the module connection socket are used. One would often gladly dispense with these connection sockets for integration of customer-specific large modules in facades. The question: ``Where will the diodes go?`` must then be satisfactorily answered. Both laminating the diodes in the module and their external accommodation cause extra expense elsewhere. It would be ideal if one could dispense with the bypass diodes altogether. This article tries to answer the question, in what conditions this is possible. Starting from the PV facade `Freiburg solar centre`, where one dispensed with the protective diodes, investigations are carried out experimentally and by means of simulation calculations. [Deutsch] Um Solarmodule bei inhomogener Bestrahlung vor hohen Verlustleistungen zu schuetzen, werden ueblicherweise Bypass-Dioden eingesetzt, die zumeist in der Modulanschlussdose untergebracht sind. Zur Fassadenintegration von kundenspezifischen Grossmodulen wuerde man manchmal gerne auf die Anschlussdosen verzichten. Hierfuer muesste zunaechst die Frage `wohin mit den Dioden?` befriedigend beantwortet werden. Sowohl die Einlaminierung der Dioden in das Modul, als auch deren externe Unterbringung versursachen an anderer Stelle einen erhoehten Aufwand. Ideal waere es, wenn man auf die Bypass-Dioden ganz verzichten koennte. Die vorliegende Arbeit versucht die Frage zu beantworten, unter welchen Bedingungen dies moeglich ist. Ausgehend von der PV-Fassade `Solarzentrum Freiburg` - hier wurde auf den Einsatz von Schutzdioden verzichtet - werden experimentell und mittels Simulationsrechnungen Untersuchungen durchgefuehrt. (orig./RHM)

  16. Impact of Rooftop Solar PV on Residential Distribution Network

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    Increased environmental awareness in recent years has encouraged rapid growth of renewable energy sources especially solar PV and wind. Among them, small scale solar PV has been gaining more momentum especially at residential level. Even today moderate penetration of grid tied rooftop solar PV has...... become reality in many countries. In spite of various benefits, higher penetration of rooftop PVs might come up with number of detrimental effects, with power quality and overcurrent protection being the major ones. Therefore, it is reasonable to quantify both drawback and benefits of rooftop PV...

  17. Solar Energy: Incentives to Promote PV in EU27

    Directory of Open Access Journals (Sweden)

    María del P. Pablo-Romero

    2013-11-01

    Full Text Available The growth in the use of renewable energies in the EU has been remarkable. Among these energies is PV. The average annual growth rate for the EU-27 countries in installed PV capacity in the period 2005-2012 was 41.2%. While the installed capacity of PV has reached almost 82 % of National Renewable Energy Action Plan (NREAP targets for the EU-27 countries for 2020, it is still far from being used at its full potential. Over recent years, several measures have been adopted in the EU to enhance and promote PV. This paper undertakes a complete review of the state of PV power in Europe and the measures taken to date to promote it in EU-27. 25 countries have adopted measures to promote PV. The most widespread measure to promote PV use is Feed- in Tariffs. Tariffs are normally adjusted, in a decreasing manner, annually. Nevertheless, currently, seven countries have decided to accelerate this decrease rate in view of cost reduction of the installations and of higher efficiencies. The second instrument used to promote PV in the EU-27 countries is the concession of subsidies. Nevertheless, subsidies have the disadvantage of being closely linked to budgetary resources and therefore to budgetary constraints. In most EU countries, subsidies for renewable energy for PV are being lowered. Twelve EU-27 countries adopted tax measures. Low-interest loans and green certificate systems were only sparingly used.

  18. Fault Analysis and Detection in Microgrids with High PV Penetration

    Energy Technology Data Exchange (ETDEWEB)

    El Khatib, Mohamed [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hernandez Alvidrez, Javier [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    In this report we focus on analyzing current-controlled PV inverters behaviour under faults in order to develop fault detection schemes for microgrids with high PV penetration. Inverter model suitable for steady state fault studies is presented and the impact of PV inverters on two protection elements is analyzed. The studied protection elements are superimposed quantities based directional element and negative sequence directional element. Additionally, several non-overcurrent fault detection schemes are discussed in this report for microgrids with high PV penetration. A detailed time-domain simulation study is presented to assess the performance of the presented fault detection schemes under different microgrid modes of operation.

  19. Evaluation of a solar PV tracking prototype on tropic regions

    Directory of Open Access Journals (Sweden)

    Cristian Manuel Agudelo Restrepo

    2016-06-01

    Full Text Available Nowadays climate change is a big concern for human society, due to our high dependence on fossil fuels. A great amount of research effort is focused in solar photovoltaic (PV systems, particularly on the improvement of the conversion efficiency. One technique commonly used is the tracking systems, where the solar PV moves with the sun in order to capture the maximum direct solar radiation. This paper presents a solar PV single-axis tracking system prototype, and a comparison regarding its energy conversion efficiency with a fixed solar PV installation. The system was tested in Fusagasugá, Colombia, which is located in the tropics region.

  20. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  1. A minimum achievable PV electrical generating cost

    Energy Technology Data Exchange (ETDEWEB)

    Sabisky, E.S. [11 Carnation Place, Lawrenceville, NJ 08648 (United States)

    1996-03-22

    The role and share of photovoltaic (PV) generated electricity in our nation`s future energy arsenal is primarily dependent on its future production cost. This paper provides a framework for obtaining a minimum achievable electrical generating cost (a lower bound) for fixed, flat-plate photovoltaic systems. A cost of 2.8 $cent/kWh (1990$) was derived for a plant located in Southwestern USA sunshine using a cost of money of 8%. In addition, a value of 22 $cent/Wp (1990$) was estimated as a minimum module manufacturing cost/price

  2. Ancillary services provided by PV power plants

    Directory of Open Access Journals (Sweden)

    Antonio PIERNO

    2016-07-01

    Full Text Available Renewable energy sources are widely utilized in distributed generation systems, and, recently, they are also considered for providing ancillary services. The paper is focused on PV plants, a survey of the most interesting papers published in the literature in the last decade is reported and the main characteristics of the technical proposals, with their advantages and limits, are evidenced. The results are schematically shown in a table that immediately gives the opportunity to be aware of what was already done, representing a reference tool.

  3. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  4. Experimental investigation of PV modules recycling; PV module recycle no jikkenteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Unagida, H.; Kurokawa, K. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Sakuta, K.; Otani, K.; Murata, K. [Electrotechnical Laboratory, Tsukuba (Japan)

    1997-11-25

    Recycling, cost/energy analysis and recovery experiment were made on crystalline silicon PV modules with EVA(ethylene vinyl acetate)-laminated structure. The life of modules is dependent not on performance deterioration of PV cells themselves but on yellowing or poor transmittance of EVA caused by ultraviolet ray, and disconnection between cells by thermal stress. Recovery is carried out in 3 stages of cell, wafer and material. Recovery in the stages of cell and wafer results in considerable reduction of energy and cost. The recovery experiment was carried out using PV module samples prepared by cutting the modules into 25times15mm pieces after removing Al frames from the used modules, peeling back sheets and cutting off EVA. Since a nitric acid process at 70-80degC can dissolve EVA effectively, it is promising for reuse of surface glass and PV cells as they are. This process is also carried out under a condition around room temperature and pressure, contributing to cost reduction and energy saving for recycling. Generation of harmful NOx is only a problem to be solved. 2 refs., 6 figs., 1 tab.

  5. Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1995-10-01

    This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

  6. Simulation of Power Produced by a Building Added PV System in Indonesia using virtual reality

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    In this study a PV system will be simulated using virtual reality software for PV system simulations -called VR4PV - to show the effectiveness of the modelling of PV systems on buildings which are placed in the tropics. The PV system used for this study has been installed in Papua, Indonesia and inc

  7. Projecting of PV facades in consideration of PV-specific operating conditions; Besonderheiten bei der Projektierung von Photovoltaik-Fassadenanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Decker, B.; Grimmig, B.; Mencke, D. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany). Gruppe Photovoltaik-Systeme; Stellbogen, D. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany). Fachgebiet Photovoltaische Anlagentechnik

    1998-02-01

    PV facades can provide several additional functions such as weather protection, thermal insulation, daylighting or sun protection. On the other hand, specific operating conditions for PV facades must be taken into account when selecting components and designing the system. Depending on ventilation conditions, there is a large range of maximum module temperatures. South-oriented PV facades receive about 30% less yearly irradiation than an optimally inclined PV generator, hence reflection losses are approximately 4% higher. The maximum of yearly irradiation lies only in the 400-600 W/m{sup 2} range. Surrounding buildings and/or vegetation can impair performance of the PV-facades. For a south-oriented PV facade an annual yield in the range of 470-560 kwh/kW{sub p}.a has been prodicted which was verified by operating results of eight PV facades. (orig.) [Deutsch] Photovoltaik (PV) Fassaden ermoeglichen neben der Stromerzeugung zusaetzliche Funktionen wie Wetterschutz bzw. Waermedaemmung des Gebaeudes oder Tageslichtnutzung bzw. Sonnenschutz der Innenraeume. Allerdings muessen fassadenspezifische Betriebsbedingungen, bei der Komponentenauswahl und Systemauslegung beruecksichtigt werden. Unterschiedliche Hinterlueftungsbedingungen fuehren zu einer grossen Bandbreite der maximalen Modultemperatur. PV-Suedfassaden empfangen etwa 30% weniger Jahreseinstrahlung als ein optimal geneigter PV-Generator. Die Haelfte der jaehrlichen Einstrahlung trifft mit Einfallswinkeln groesser 50 auf die vertikal angeordneten Module wodurch die Reflexionsverluste um ca. 4% hoeher sind. Das Maximum der Jahreseinstrahlung liegt nur um 400-600 W/m{sup 2} und erreicht selten Werte ueber 800 W/m{sup 2}. Umliegende Gebaeude oder Vegetation koennen zu Teilabschattungen des Generators fuehren. Fuer eine vertikale PV-Suedfassade wird ein Jahresenergieertrag in Hoehe von 470-560 kWh/kW{sub p}.a prognostiziert, der anhand der Betriebsergebnisse von acht PV-Fassadenanlagen verifiziert werden konnte

  8. A LOV protein modulates the physiological attributes of Xanthomonas axonopodis pv. citri relevant for host plant colonization.

    Directory of Open Access Journals (Sweden)

    Ivana Kraiselburd

    Full Text Available Recent studies have demonstrated that an appropriate light environment is required for the establishment of efficient vegetal resistance responses in several plant-pathogen interactions. The photoreceptors implicated in such responses are mainly those belonging to the phytochrome family. Data obtained from bacterial genome sequences revealed the presence of photosensory proteins of the BLUF (Blue Light sensing Using FAD, LOV (Light, Oxygen, Voltage and phytochrome families with no known functions. Xanthomonas axonopodis pv. citri is a Gram-negative bacterium responsible for citrus canker. The in silico analysis of the X. axonopodis pv. citri genome sequence revealed the presence of a gene encoding a putative LOV photoreceptor, in addition to two genes encoding BLUF proteins. This suggests that blue light sensing could play a role in X. axonopodis pv. citri physiology. We obtained the recombinant Xac-LOV protein by expression in Escherichia coli and performed a spectroscopic analysis of the purified protein, which demonstrated that it has a canonical LOV photochemistry. We also constructed a mutant strain of X. axonopodis pv. citri lacking the LOV protein and found that the loss of this protein altered bacterial motility, exopolysaccharide production and biofilm formation. Moreover, we observed that the adhesion of the mutant strain to abiotic and biotic surfaces was significantly diminished compared to the wild-type. Finally, inoculation of orange (Citrus sinensis leaves with the mutant strain of X. axonopodis pv. citri resulted in marked differences in the development of symptoms in plant tissues relative to the wild-type, suggesting a role for the Xac-LOV protein in the pathogenic process. Altogether, these results suggest the novel involvement of a photosensory system in the regulation of physiological attributes of a phytopathogenic bacterium. A functional blue light receptor in Xanthomonas spp. has been described for the first time, showing

  9. Oxynitride Thin Film Barriers for PV Packaging

    Energy Technology Data Exchange (ETDEWEB)

    Glick, S. H.; delCueto, J. A.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2005-11-01

    Dielectric thin-film barrier and adhesion-promoting layers consisting of silicon oxynitride materials (SiOxNy, with various stoichiometry) were investigated. For process development, films were applied to glass (TCO, conductive SnO2:F; or soda-lime), polymer (PET, polyethylene terephthalate), aluminized soda-lime glass, or PV cell (a-Si, CIGS) substrates. Design strategy employed de-minimus hazard criteria to facilitate industrial adoption and reduce implementation costs for PV manufacturers or suppliers. A restricted process window was explored using dilute compressed gases (3% silane, 14% nitrous oxide, 23% oxygen) in nitrogen (or former mixtures, and 11.45% oxygen mix in helium and/or 99.999% helium dilution) with a worst-case flammable and non-corrosive hazard classification. Method employed low radio frequency (RF) power, less than or equal to 3 milliwatts per cm2, and low substrate temperatures, less than or equal to 100 deg C, over deposition areas less than or equal to 1000 cm2. Select material properties for barrier film thickness (profilometer), composition (XPS/FTIR), optical (refractive index, %T and %R), mechanical peel strength and WVTR barrier performance are presented.

  10. The Xanthomonas oryzae pv. oryzae PhoPQ two-component system is required for AvrXA21 activity, hrpG expression, and virulence.

    Science.gov (United States)

    Lee, Sang-Won; Jeong, Kyu-Sik; Han, Sang-Wook; Lee, Seung-Eun; Phee, Bong-Kwan; Hahn, Tae-Ryong; Ronald, Pamela

    2008-03-01

    The rice pathogen recognition receptor, XA21, confers resistance to Xanthomonas oryzae pv. oryzae strains producing the type one system-secreted molecule, AvrXA21. X. oryzae pv. oryzae requires a regulatory two-component system (TCS) called RaxRH to regulate expression of eight rax (required for AvrXA21 activity) genes and to sense population cell density. To identify other key components in this critical regulatory circuit, we assayed proteins expressed in a raxR gene knockout strain. This survey led to the identification of the phoP gene encoding a response regulator that is up-regulated in the raxR knockout strain. Next we generated a phoP knockout strain and found it to be impaired in X. oryzae pv. oryzae virulence and no longer able to activate the response regulator HrpG (hypersensitive reaction and pathogenicity G) in response to low levels of Ca2+. The impaired virulence of the phoP knockout strain can be partially complemented by constitutive expression of hrpG, indicating that PhoP controls a key aspect of X. oryzae pv. oryzae virulence through regulation of hrpG. A gene encoding the cognate putative histidine protein kinase, phoQ, was also isolated. Growth curve analysis revealed that AvrXA21 activity is impaired in a phoQ knockout strain as reflected by enhanced growth of this strain in rice lines carrying XA21. These results suggest that the X. oryzae pv. oryzae PhoPQ TCS functions in virulence and in the production of AvrXA21 in partnership with RaxRH.

  11. National survey report on PV power applications in Switzerland 2006

    Energy Technology Data Exchange (ETDEWEB)

    Huesser, P. [Nova Energie GmbH, Aarau (Switzerland); Hostettler, T. [Ingenieurbuero Hostettler, Berne (Switzerland)

    2007-07-01

    This annual report was published by the Swiss Federal Office of Energy (SFOE) as part of the International Energy Agency's work on the exchange and dissemination of information on photovoltaic power systems (PVPS). The political situation in Switzerland with regard to the promotion of photovoltaics (PV) and new legislation in the energy area is discussed. The report provides information on installed PV power, costs and prices and the Swiss PV industry. Examples of PV applications are presented and data on the cumulative installed PV power in various application sectors is presented and discussed. Highlights, major projects and various demonstration and field-test programmes are dealt with, as are public budgets for market stimulation. Figures on the development, production and prices of PV cells and modules are presented. Swiss balance-of-system products are reviewed, as are PV-related services and the value of the Swiss PV business. A review of non-technical factors and new initiatives completes the report.

  12. Product integrated PV: the future is design and styling

    NARCIS (Netherlands)

    Eggink, Wouter; Reinders, Angèle

    2016-01-01

    In this paper we explore how PV powered products have been designed in the past. For this purpose we have drawn a historical time line of the design features of PV powered products in the context of main stream design and styling. Our time frame is 1970 till 2016, focusing in first instance on consu

  13. Energy requirements and CO2 mitigation potential of PV systems

    NARCIS (Netherlands)

    Alsema, E.A.

    2006-01-01

    In this paper we investigate the energy requirements of PV modules and systems and calculate the Energy Pay-Back Time for two major PV applications. Based on a review of past energy analysis studies we explain the main sources of differences and establish a "best estimate" for key system components.

  14. PV O&M Cost Model and Cost Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Andy

    2017-03-15

    This is a presentation on PV O&M cost model and cost reduction for the annual Photovoltaic Reliability Workshop (2017), covering estimating PV O&M costs, polynomial expansion, and implementation of Net Present Value (NPV) and reserve account in cost models.

  15. Applications of ``PV Optics`` for solar cell and module design

    Energy Technology Data Exchange (ETDEWEB)

    Sopori, B.L.; Madjdpour, J.; Chen, W. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    This paper describes some applications of a new optics software package, PV Optics, developed for the optical design of solar cells and modules. PV Optics is suitable for the analysis and design of both thick and thin solar cells. It also includes a feature for calculation of metallic losses related to contacts and back reflectors.

  16. Development of PV powered consumer products using future scenarios

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Meulen, van der B.J.R.; Eger, A.O.

    2006-01-01

    Given the high potential of PV technology to reduce the environmental impact of electricity use of consumer products, it would be worthwhile to advance the application of PV systems in mass produced products. To date this field of application has been explored only to a limited extent. For this reas

  17. Analysis of Long-Term Performance of PV Systems

    NARCIS (Netherlands)

    Nordmann, T.; Clavadetscher, L.; van Sark, Wilfried; Green, M.

    2015-01-01

    This report describes the activities, conclusions and continued efforts undertaken in Subtask 1 by the participating countries in IEA-PVPS Task 13. Subtask 1 examines the PV power plant as a system. It collects and studies the data supplied from installed operating PV plants from different countries

  18. Solar PV Energy Conversion System and its Configurations

    OpenAIRE

    Ahteshamul Haque

    2016-01-01

    Solar PV based energy conversion system is now used in commercial and residential buildings. Advancements in Power electronics leads the researchers to enhance the use of solar application in various configurations. These configurations may be used to utilize the energy optimally. The main objective of this paper is to present an overview of the various configurations of solar PV energy conversion system

  19. Isolation and Characterization of Bacteriophages Against Pseudomonas syringae pv. actinidiae Causing Bacterial Canker Disease in Kiwifruit.

    Science.gov (United States)

    Yu, Ji-Gang; Lim, Jeong-A; Song, Yu-Rim; Heu, Sunggi; Kim, Gyoung Hee; Koh, Young Jin; Oh, Chang-Sik

    2016-02-01

    Pseudomonas syringae pv. actinidiae causes bacterial canker disease in kiwifruit. Owing to the prohibition of agricultural antibiotic use in major kiwifruit-cultivating countries, alternative methods need to be developed to manage this disease. Bacteriophages are viruses that specifically infect target bacteria and have recently been reconsidered as potential biological control agents for bacterial pathogens owing to their specificity in terms of host range. In this study, we isolated bacteriophages against P. syringae pv. actinidiae from soils collected from kiwifruit orchards in Korea and selected seven bacteriophages for further characterization based on restriction enzyme digestion patterns of genomic DNA. Among the studied bacteriophages, two belong to the Myoviridae family and three belong to the Podoviridae family, based on morphology observed by transmission electron microscopy. The host range of the selected bacteriophages was confirmed using 18 strains of P. syringae pv. actinidiae, including the Psa2 and Psa3 groups, and some were also effective against other P. syringae pathovars. Lytic activity of the selected bacteriophages was sustained in vitro until 80 h, and their activity remained stable up to 50°C, at pH 11, and under UV-B light. These results indicate that the isolated bacteriophages are specific to P. syringae species and are resistant to various environmental factors, implying their potential use in control of bacterial canker disease in kiwifruits.

  20. Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John

    2016-06-06

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  1. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael D.; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John H.

    2016-11-21

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  2. PvRON2, a new Plasmodium vivax rhoptry neck antigen

    Directory of Open Access Journals (Sweden)

    Curtidor Hernando

    2011-03-01

    Full Text Available Abstract Background Rhoptries are specialized organelles from parasites belonging to the phylum Apicomplexa; they secrete their protein content during invasion of host target cells and are sorted into discrete subcompartments within rhoptry neck or bulb. This distribution is associated with these proteins' role in tight junction (TJ and parasitophorous vacuole (PV formation, respectively. Methods Plasmodium falciparum RON2 amino acid sequence was used as bait for screening the codifying gene for the homologous protein in the Plasmodium vivax genome. Gene synteny, as well as identity and similarity values, were determined for ron2 and its flanking genes among P. falciparum, P. vivax and other malarial parasite genomes available at PlasmoDB and Sanger Institute databases. Pvron2 gene transcription was determined by RT-PCR of cDNA obtained from the P. vivax VCG-1 strain. Protein expression and localization were assessed by Western blot and immunofluorescence using polyclonal anti-PvRON2 antibodies. Co-localization was confirmed using antibodies directed towards specific microneme and rhoptry neck proteins. Results and discussion The first P. vivax rhoptry neck protein (named here PvRON2 has been identified in this study. PvRON2 is a 2,204 residue-long protein encoded by a single 6,615 bp exon containing a hydrophobic signal sequence towards the amino-terminus, a transmembrane domain towards the carboxy-terminus and two coiled coil α-helical motifs; these are characteristic features of several previously described vaccine candidates against malaria. This protein also contains two tandem repeats within the interspecies variable sequence possibly involved in evading a host's immune system. PvRON2 is expressed in late schizonts and localized in rhoptry necks similar to what has been reported for PfRON2, which suggests its participation during target cell invasion. Conclusions The identification and partial characterization of the first P. vivax

  3. A global strategy for the European PV industry

    Energy Technology Data Exchange (ETDEWEB)

    Viaud, M.; Despotou, E.; Latour, M. [European Photovoltaic Industry Association (EPIA) secretariat, Brussels (Belgium); Hoffmann, W.; Macias, E.; Cameron, M.; Laborde, E. [European Photovoltaic Industry Association (EPIA), Brussels (Belgium)

    2004-07-01

    The objective was to develop a comprehensive strategy that answers to the need of today European PV industry. Namely: - Develop PV markets in Europe - Develop export markets. - Position the European PV industry within the European political environment and support the effort of national actors in their local objectives. This method lends itself to brainstorming to create actions and synergies, on order to achieve strategy objectives. The whole work is based on working groups clearly defined on the purpose, where all EPIA members are invited to participate. The overall first results are presented during the 19. EU PV Conference in Paris and EPIA will do recommendations on actions to be undertaken in the future. This strategy is co-financed by EPIA members and the 6. Framework Programme for research of the European Commission through the PV Catapult project. (authors)

  4. Optimum Design Of On Grid Pv System Using Tracking System

    Directory of Open Access Journals (Sweden)

    Saeed Mansour

    2015-05-01

    Full Text Available Abstract The fossil fuel is a main issue in the world due to the increase of fossil fuel cost and the depletion of the fossil fuel with continuous increasing demand on electricity. With continuous decrease of PV panels cost it is interesting to consider generation of electricity from PV system. To provide electric energy to a load in a remote area where electric grid utility is not available or connection with grid utility is available there are two approaches of photovoltaic system PV without tracking system Fixed System and PV with tracking systems. The result shows that the energy production by using PV with tracking system generates more energy in comparison with fixed panels system. However the cost per produced KWH is less in case of using fixed panels. This is the backbone in choice between two approaches of photovoltaic system. In this work a system design and cost analysis for two approaches of photovoltaic system are considered.

  5. Costs of Residential Solar PV Plants in Distribution Grid Networks

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Yang, Guangya; Ipsen, Hans Henrik

    2015-01-01

    In this article we investigate the impact of residential solar PV plants on energy losses in distribution networks and their impact on distribution transformers lifetime. Current guidelines in Denmark states that distribution transformers should not be loaded with more than 67% solar PV power...... to avoid accelerated loss of life. If a solar PV plant causes this limit to be exceeded, the particular owner has to pay for upgrading the transformer. Distribution Network Operators also charge an annual tariff from the solar PV plants to cover the expenses to keep the grid capacity available, the so...... called “Availability Tariff”. According to the Danish Energy Regulatory Authority, the Availability Tariff must cover the exact expenses, with energy savings etc. from the solar PV plants taken into consideration. Our conclusion is that a distribution network, which represents a typical residential...

  6. Overview of Recent Grid Codes for PV Power Integration

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2012-01-01

    and Distribution System Operators (DSOs) had to keep the safety and reliability of the network under strict rules and regulations. The aim of the paper is to realize a survey of recent Grid Codes (GC) and regulations for grid connected PV systems. The focus is on grid interface requirements, power quality concerns...... and Anti-Islanding (AI) issues regarding PV systems connected to low voltage (LV) and medium voltage (MV) levels of the network.......The challenge to bring down the cost of produced photovoltaic (PV) power had a major impact on the PV market and in consequence the grid operators experienced higher and higher PV power penetration. The growing share of this decentralized generation plants started to affect the grid stability...

  7. Fire hazard and other safety concerns of PV systems

    Science.gov (United States)

    Dhere, Neelkanth G.

    2011-09-01

    Photovoltaic modules are usually considered safe and reliable. But in case of grid-connected PV systems that are becoming very popular, the issue of fire safety of PV modules is becoming increasingly important due to the employed high voltages of 600 V to 1000 V. The two main factors i.e. open circuiting of the bypass diode and ground fault that are responsible for the fire in the PV systems have been discussed in detail along with numerous real life examples. Recommendations are provided for preventing the fire hazards such as having at least class C fire rated PV modules, proper bypass and blocking diodes and interestingly, having an ungrounded PV system.

  8. Codes, standards, and PV power systems. A 1996 status report

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, J

    1996-06-01

    As photovoltaic (PV) electrical power systems gain increasing acceptance for both off-grid and utility-interactive applications, the safety, durability, and performance of these systems gains in importance. Local and state jurisdictions in many areas of the country require that all electrical power systems be installed in compliance with the requirements of the National Electrical Code{reg_sign} (NEC{reg_sign}). Utilities and governmental agencies are now requiring that PV installations and components also meet a number of Institute of Electrical and Electronic Engineers (IEEE) standards. PV installers are working more closely with licensed electricians and electrical contractors who are familiar with existing local codes and installation practices. PV manufacturers, utilities, balance of systems manufacturers, and standards representatives have come together to address safety and code related issues for future PV installations. This paper addresses why compliance with the accepted codes and standards is needed and how it is being achieved.

  9. Costs of Residential Solar PV Plants in Distribution Grid Networks

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Yang, Guangya; Ipsen, Hans Henrik

    2015-01-01

    In this article we investigate the impact of residential solar PV plants on energy losses in distribution networks and their impact on distribution transformers lifetime. Current guidelines in Denmark states that distribution transformers should not be loaded with more than 67% solar PV power...... called “Availability Tariff”. According to the Danish Energy Regulatory Authority, the Availability Tariff must cover the exact expenses, with energy savings etc. from the solar PV plants taken into consideration. Our conclusion is that a distribution network, which represents a typical residential...... to avoid accelerated loss of life. If a solar PV plant causes this limit to be exceeded, the particular owner has to pay for upgrading the transformer. Distribution Network Operators also charge an annual tariff from the solar PV plants to cover the expenses to keep the grid capacity available, the so...

  10. Physical Effects of Distributed PV Generation on California's Distribution System

    CERN Document Server

    Cohen, Michael A

    2015-01-01

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  11. The PseEF efflux system is a virulence factor of Pseudomonas syringae pv. syringae.

    Science.gov (United States)

    Cho, Hyosun; Kang, Hyojeung

    2012-02-01

    An ATP-binding cassette (ABC) transporter, called the PseEF efflux system, was identified at the left border of the syr-syp genomic island of Pseudomonas syringae pv. syringae strain B301D. The PseEF efflux system was located within a 3.3-kb operon that encodes a periplasmic membrane fusion protein (PseE), and an ABC-type cytoplasmic membrane protein (PseF). The PseEF efflux system exhibited amino acid homology to a putative ABC efflux system (MacAB) of E. coli W3104 with identities of 47.2% (i.e., PseE to MacA) and 57.6% (i.e., PseF to MacB). A nonpolar mutation within the pseF gene was generated by nptII insertional mutagenesis. The resultant mutant strain showed significant reduction in secretion of syringomycin (74%) and syringopeptin (71%), as compared to parental strain B301D. Quantitative real-time RT-PCR was used to determine transcript levels of the syringomycin (syrB1) and syringopeptin (sypA) synthetase genes in strain B301D-HK7 (a pseF mutant). Expression of the sypA gene by mutant strain B301D-HK7 was approximately 6.9% as compared to that of parental strain B301D, while the syrB1 gene expression by mutant strain B301D-HK7 was nearly 14.6%. In addition, mutant strain B301D-HK7 was less virulent by approximately 67% than parental strain B301D in immature cherry fruits. Mutant strain B301D-HK7 was not reduced in resistance to any antibiotics used in this study as compared to parental strain B301D. Expression (transcript levels) of the pseF gene was induced approximately six times by strain B301D grown on syringomycin minimum medium (SRM) supplemented with the plant signal molecules arbutin and D-fructose (SRMAF), as compared to that of strain B301D grown on SRM (in the absence of plant signal molecules). In addition, during infection of bean plants by P. syringae pv. syringae strain B728a, expression of the pseF gene increased at 3 days after inoculation (dai). More than 180-fold induction was observed in transcript levels of the pseF gene by parental

  12. PV Performance Modeling Methods and Practices: Results from the 4th PV Performance Modeling Collaborative Workshop.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    In 2014, the IEA PVPS Task 13 added the PVPMC as a formal activity to its technical work plan for 2014-2017. The goal of this activity is to expand the reach of the PVPMC to a broader international audience and help to reduce PV performance modeling uncertainties worldwide. One of the main deliverables of this activity is to host one or more PVPMC workshops outside the US to foster more international participation within this collaborative group. This report reviews the results of the first in a series of these joint IEA PVPS Task 13/PVPMC workshops. The 4th PV Performance Modeling Collaborative Workshop was held in Cologne, Germany at the headquarters of TÜV Rheinland on October 22-23, 2015.

  13. Innovations in Wind and Solar PV Financing

    Energy Technology Data Exchange (ETDEWEB)

    Cory, K.; Coughlin, J.; Jenkin, T.; Pater, J.; Swezey, B.

    2008-02-01

    There is growing national interest in renewable energy development based on the economic, environmental, and security benefits that these resources provide. Historically, greater development of our domestic renewable energy resources has faced a number of hurdles, primarily related to cost, regulation, and financing. With the recent sustained increase in the costs and associated volatility of fossil fuels, the economics of renewable energy technologies have become increasingly attractive to investors, both large and small. As a result, new entrants are investing in renewable energy and new business models are emerging. This study surveys some of the current issues related to wind and solar photovoltaic (PV) energy project financing in the electric power industry, and identifies both barriers to and opportunities for increased investment.

  14. Fidelity Susceptibility as Holographic PV criticality

    CERN Document Server

    Momeni, Davood; Myrzakulov, Ratbay

    2016-01-01

    Motivated by the fact that the quantum entanglement entropy is dual to an area in AdS, quantities dual to a volume in the AdS have also been recently proposed. These include the holographic complexity and fidelity susceptibility of a quantum system. Even though both of them are dual to an volume in the bulk, there are some interesting difference between them. In this letter, we will explicitly compare them for an $ AdS _4$ solution, and clarify the main differences between them from thermodynamic point of the view. We will also obtain the correct and appropriate holographic dual of the thermodynamic volume of AdS blackhole, and demonstrate that to explain therodynamic in extended phase PV picture, from the AdS/CFT point of view,fidelity susceptibility is the preferred quantity in comparison to holographic complexity.

  15. Quorum-sensing system affects gall development incited by Pantoea agglomerans pv. gypsophilae.

    Science.gov (United States)

    Chalupowicz, Laura; Manulis-Sasson, Shulamit; Itkin, Maxim; Sacher, Ayelet; Sessa, Guido; Barash, Isaac

    2008-08-01

    The quorum-sensing (QS) regulatory system of the gall-forming Pantoea agglomerans pv. gypsophilae was identified. Mass spectral analysis, together with signal-specific biosensors, demonstrated that P. agglomerans pv. gypsophilae produced N-butanoyl-l-homoserine lactone (C4-HSL) as a major and N-hexanoyl-l-homoserine lactone (C6-HSL) as a minor QS signal. Homologs of luxI and luxR regulatory genes, pagI and pagR, were characterized in strain P. agglomerans pv. gypsophilae Pag824-1 and shown to be convergently transcribed and separated by 14 bp. The deduced PagI (23.8 kDa) and PagR (26.9 kDa) show high similarity with SmaI (41% identity) and SmaR (43% identity), respectively, of Serratia sp. American Type Culture Collection 39006. PagR possesses characteristic autoinducer binding and a helix-turn-helix DNA-binding domain. Gall formation by P. agglomerans pv. gypsophilae depends on a plasmid-borne hrp/hrc gene cluster, type III effectors, and phytohormones. Disruption of pagI, pagR, or both genes simultaneously in Pag824-1 reduced gall size in gypsophila cuttings by 50 to 55% when plants were inoculated with 10(6) CFU/ml. Higher reductions in gall size (70 to 90%) were achieved by overexpression of pagI or addition of exogenous C4-HSL. Expression of the hrp/hrc regulatory gene hrpL and the type III effector pthG in the pagI mutant, as measured with quantitative reverse-transcriptase polymerase chain reaction, was reduced by 5.8 and 6.6, respectively, compared with the wild type, suggesting an effect of the QS system on the Hrp regulon.

  16. Pseudomonas syringae pv. phaseolicola Mutants Compromised for type III secretion system gene induction.

    Science.gov (United States)

    Deng, Xin; Xiao, Yanmei; Lan, Lefu; Zhou, Jian-Min; Tang, Xiaoyan

    2009-08-01

    Pseudomonas syringae bacteria utilize the type III secretion system (T3SS) to deliver effector proteins into host cells. The T3SS and T3 effector genes (together called the T3 genes hereafter) are repressed in nutrient-rich medium but rapidly induced after the bacteria are transferred into minimal medium or infiltrated into plants. The induction of the T3 genes is mediated by HrpL, an alternative sigma factor that recognizes the conserved hrp box motif in the T3 gene promoters. The induction of hrpL is mediated by HrpR and HrpS, two homologous proteins that bind the hrpL promoter. To identify additional genes involved in regulation of the T3 genes, we screened for the P. syringae pv. phaseolicola NPS3121 transposon-tagged mutants with reduced induction of avrPto-luc and hrpL-luc, reporter genes for promoters of effector gene avrPto and hrpL, respectively. Determination of the transposon-insertion sites revealed genes with putative functions in signal transduction and transcriptional regulation, protein synthesis, and basic metabolism. A transcriptional regulator (AefR(NPS3121)) was identified in our screen that is homologous to AefR of P. syringae pv. syringae strain B728a, a regulator of the quorum-sensing signal and epiphytic traits, but was not known to regulate the T3 genes. AefR(NPS3121) in P. syringae pv. phaseolicola NPS3121 and AefR in P. syringae pv. syringae B728a behave similarly in regulating the quorum-sensing signal in liquid medium but differ in regulating the epiphytic traits, including swarming motility, leaf entry, and epiphytic survival.

  17. Pigment and Virulence Deficiencies Associated with Mutations in the aroE Gene of Xanthomonas oryzae pv. oryzae

    OpenAIRE

    2001-01-01

    Xanthomonadins are yellow, membrane-bound pigments produced by members of the genus Xanthomonas. We identified an ethyl methanesulfonate-induced Xanthomonas oryzae pv. oryzae mutant (BXO65) that is deficient for xanthomonadin production and virulence on rice, as well as auxotrophic for aromatic amino acids (Pig− Vir− Aro−). Reversion analysis indicated that these multiple phenotypes are due to a single mutation. A genomic library of the wild-type strain was used to isolate a 7.0-kb clone that...

  18. Sobrevivência de Xanthomonas axonopodis pv. manihotis em manipueira sob condições ambientais Survival of Xanthomonas axonopodis pv. manihotis in "manipueira" under environmental conditions

    Directory of Open Access Journals (Sweden)

    Gustavo de Faria Theodoro

    2002-07-01

    Full Text Available O objetivo deste trabalho foi avaliar a sobrevivência de um isolado de Xanthomonas axonopodis pv. manihotis (Xam, resistente ao sulfato de estreptomicina, em manipueira incubada em condições ambientais, em três épocas (março, julho e outubro de 2000. Foram utilizados um meio de cultura semi-seletivo para o isolamento de X. axonopodis pv. manihotis e a técnica de reação de polimerase em cadeia (PCR ou de amplificação biológica (BIO-PCR. Foram determinados o pH e a acidez total da manipueira durante o período de incubação estudado. O isolado sobreviveu por um período inferior a 24 horas, nas três épocas do ano. A técnica de PCR ou BIO-PCR não foi eficaz em monitorar a sobrevivência do isolado em manipueira, pois apresentou resultados contraditórios e não confiáveis. Observou-se queda do pH e aumento da acidez total da manipueira incubada nas condições estudadas, que pode explicar o comportamento da sobrevivência de Xam em manipueira.The objective of this work was to evaluate the survival of a Xanthomonas axonopodis pv. manihotis (Xam strain, resistant to streptomycin sulfate, in "manipueira" (cassava residue incubated under environmental conditions, in three periods of the year (March, July and October 2000. A semi-selective culture medium and the polymerase chain reaction (PCR or biological amplification (BIO-PCR methods were used. The pH and the total acidity of the "manipueira" were determined during the incubation period. The strain survived less than 24 hours in the three periods of the year. The PCR or BIO-PCR method was not effective in monitoring the strain survival in "manipueira", as it showed contradictory and unreliable results. An increase in total acidity and a decrease in pH of the "manipueira" were observed, explaining the survival behavior of Xam strain.

  19. Managing PV Power on Mars - MER Rovers

    Science.gov (United States)

    Stella, Paul M.; Chin, Keith; Wood, Eric; Herman, Jennifer; Ewell, Richard

    2009-01-01

    The MER Rovers have recently completed over 5 years of operation! This is a remarkable demonstration of the capabilities of PV power on the Martian surface. The extended mission required the development of an efficient process to predict the power available to the rovers on a day-to-day basis. The performance of the MER solar arrays is quite unlike that of any other Space array and perhaps more akin to Terrestrial PV operation, although even severe by that comparison. The impact of unpredictable factors, such as atmospheric conditions and dust accumulation (and removal) on the panels limits the accurate prediction of array power to short time spans. Based on the above, it is clear that long term power predictions are not sufficiently accurate to allow for detailed long term planning. Instead, the power assessment is essentially a daily activity, effectively resetting the boundary points for the overall predictive power model. A typical analysis begins with the importing of the telemetry from each rover's previous day's power subsystem activities. This includes the array power generated, battery state-of-charge, rover power loads, and rover orientation, all as functions of time. The predicted performance for that day is compared to the actual performance to identify the extent of any differences. The model is then corrected for these changes. Details of JPL's MER power analysis procedure are presented, including the description of steps needed to provide the final prediction for the mission planners. A dust cleaning event of the solar array is also highlighted to illustrate the impact of Martian weather on solar array performance

  20. Valley of Death analysis for polymer PV technology; Valley of Death analyse voor polymere PV technologie

    Energy Technology Data Exchange (ETDEWEB)

    Schoots, K. [ECN Beleidsstudies, Petten (Netherlands)

    2013-12-15

    This report describes the results of a qualitative study of the barriers that actors involved in the development and commercialization of polymer solar cells, may encounter. The purpose of this socio-economic research is to identify these barriers for the (market) development of thin film polymeric PV technology and to develop strategies for them in order to overcome the constraints. The necessary data are collected from interviews with actors who are active in the development and deployment of conventional solar cells. Based on the results from this study, it is conclude that it is important for the Organic PV industry to carry out many market experiments beyond the built environment. The report provides recommendations with regard to the markets in which these experiments are most likely to succeed and which drivers should be taken into account [Dutch] Dit rapport beschrijft de resultaten van een kwalitatief onderzoek naar de barrieres die actoren, betrokken bij de ontwikkeling en marktintroductie van polymere zonnecellen, kunnen tegenkomen. Het doel van dit sociaal-economische onderzoek is deze barrieres voor de (markt)ontwikkeling van dunne film polymere PV technologie te identificeren en strategieen te ontwikkelen om ze voor te zijn of ze te overbruggen. De benodigde gegevens worden verzameld uit interviews met actoren die actief zijn in de ontwikkeling en uitrol van conventionele zonnecellen. Op basis van de resultaten uit dit onderzoek komen we tot de conclusie dat het voor de Organische PV sector belangrijk is veel marktexperimenten aan te gaan buiten de gebouwde omgeving. Het rapport geeft aanbevelingen in welke soort markten deze experimenten de meeste kans van slagen hebben en met welke drivers van marktpartijen rekening moet worden gehouden.

  1. SunShot 2030 for Photovoltaics (PV): Envisioning a Low-cost PV Future

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Frew, Bethany A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Richards, James [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sun, Yinong [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Woodhouse, Michael A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-12

    In this report we summarize the implications, impacts, and deployment potential of reaching the SunShot 2030 targets for the electricity system in the contiguous United States. We model 25 scenarios of the U.S. power sector using the Regional Energy Deployment Systems (ReEDS) and Distributed Generation (dGen) capacity expansion models. The scenarios cover a wide range of sensitivities to capture future uncertainties relating to fuel prices, retirements, renewable energy capital costs, and load growth. We give special attention to the potential for storage costs to also rapidly decline due to its large synergies with low-cost solar. The ReEDS and dGen models project utility- and distributed-scale power sector evolution, respectively, for the United States. Both models have been designed with special emphasis on capturing the unique traits of renewable energy, including variability and grid integration requirements. Across the suite of scenarios modeled, we find that reaching the SunShot 2030 target has the potential to lead to significant capacity additions of PV in the United States. By 2050, PV penetration levels are projected to reach 28-46 percent of total generation. If storage also sees significant reductions in cost, then the 2050 solar penetration levels could reach 41-64 percent. PV deployment is projected to occur in all of the lower 48 states, though the specific deployment level is scenario dependent. The growth in PV is projected to be dominated by utility-scale systems, but the actual mix between utility and distributed systems could ultimately vary depending on how policies, system costs, and rate structures evolve.

  2. Vibrio vulnificus phage PV94 is closely related to temperate phages of V. cholerae and other Vibrio species.

    Science.gov (United States)

    Pryshliak, Mark; Hammerl, Jens A; Reetz, Jochen; Strauch, Eckhard; Hertwig, Stefan

    2014-01-01

    Vibrio vulnificus is an important pathogen which can cause serious infections in humans. Yet, there is limited knowledge on its virulence factors and the question whether temperate phages might be involved in pathogenicity, as is the case with V. cholerae. Thus far, only two phages (SSP002 and VvAW1) infecting V. vulnificus have been genetically characterized. These phages were isolated from the environment and are not related to Vibrio cholerae phages. The lack of information on temperate V. vulnificus phages prompted us to isolate those phages from lysogenic strains and to compare them with phages of other Vibrio species. In this study the temperate phage PV94 was isolated from a V. vulnificus biotype 1 strain by mitomycin C induction. PV94 is a myovirus whose genome is a linear double-stranded DNA of 33,828 bp with 5'-protruding ends. Sequence analysis of PV94 revealed a modular organization of the genome. The left half of the genome comprising the immunity region and genes for the integrase, terminase and replication proteins shows similarites to V. cholerae kappa phages whereas the right half containing genes for structural proteins is closely related to a prophage residing in V. furnissii NCTC 11218. We present the first genomic sequence of a temperate phage isolated from a human V. vulnificus isolate. The sequence analysis of the PV94 genome demonstrates the wide distribution of closely related prophages in various Vibrio species. Moreover, the mosaicism of the PV94 genome indicates a high degree of horizontal genetic exchange within the genus Vibrio, by which V. vulnificus might acquire virulence-associated genes from other species.

  3. Vibrio vulnificus phage PV94 is closely related to temperate phages of V. cholerae and other Vibrio species.

    Directory of Open Access Journals (Sweden)

    Mark Pryshliak

    Full Text Available BACKGROUND: Vibrio vulnificus is an important pathogen which can cause serious infections in humans. Yet, there is limited knowledge on its virulence factors and the question whether temperate phages might be involved in pathogenicity, as is the case with V. cholerae. Thus far, only two phages (SSP002 and VvAW1 infecting V. vulnificus have been genetically characterized. These phages were isolated from the environment and are not related to Vibrio cholerae phages. The lack of information on temperate V. vulnificus phages prompted us to isolate those phages from lysogenic strains and to compare them with phages of other Vibrio species. RESULTS: In this study the temperate phage PV94 was isolated from a V. vulnificus biotype 1 strain by mitomycin C induction. PV94 is a myovirus whose genome is a linear double-stranded DNA of 33,828 bp with 5'-protruding ends. Sequence analysis of PV94 revealed a modular organization of the genome. The left half of the genome comprising the immunity region and genes for the integrase, terminase and replication proteins shows similarites to V. cholerae kappa phages whereas the right half containing genes for structural proteins is closely related to a prophage residing in V. furnissii NCTC 11218. CONCLUSION: We present the first genomic sequence of a temperate phage isolated from a human V. vulnificus isolate. The sequence analysis of the PV94 genome demonstrates the wide distribution of closely related prophages in various Vibrio species. Moreover, the mosaicism of the PV94 genome indicates a high degree of horizontal genetic exchange within the genus Vibrio, by which V. vulnificus might acquire virulence-associated genes from other species.

  4. Sub-synchronous resonance damping using high penetration PV plant

    Science.gov (United States)

    Khayyatzadeh, M.; Kazemzadeh, R.

    2017-02-01

    The growing need to the clean and renewable energy has led to the fast development of transmission voltage-level photovoltaic (PV) plants all over the world. These large scale PV plants are going to be connected to power systems and one of the important subjects that should be investigated is the impact of these plants on the power system stability. Can large scale PV plants help to damp sub-synchronous resonance (SSR) and how? In this paper, this capability of a large scale PV plant is investigated. The IEEE Second Benchmark Model aggregated with a PV plant is utilized as the case study. A Wide Area Measurement System (WAMS) based conventional damping controller is designed and added to the main control loop of PV plant in order to damp the SSR and also investigation of the destructive effect of time delay in remote feedback signal. A new optimization algorithm called teaching-learning-based-optimization (TLBO) algorithm has been used for managing the optimization problems. Fast Furrier Transformer (FFT) analysis and also transient simulations of detailed nonlinear system are considered to investigate the performance of the controller. Robustness of the proposed system has been analyzed by facing the system with disturbances leading to significant changes in generator and power system operating point, fault duration time and PV plant generated power. All the simulations are carried out in MATLAB/SIMULINK environment.

  5. Three junction holographic micro-scale PV system

    Science.gov (United States)

    Wu, Yuechen; Vorndran, Shelby; Ayala Pelaez, Silvana; Kostuk, Raymond K.

    2016-09-01

    In this work a spectrum splitting micro-scale concentrating PV system is evaluated to increase the conversion efficiency of flat panel PV systems. In this approach, the dispersed spectrum splitting concentration systems is scaled down to a small size and structured in an array. The spectrum splitting configuration allows the use of separate single bandgap PV cells that increase spectral overlap with the incident solar spectrum. This results in an overall increase in the spectral conversion efficiency of the resulting system. In addition other benefits of the micro-scale PV system are retained such reduced PV cell material requirements, more versatile interconnect configurations, and lower heat rejection requirements that can lead to a lower cost system. The system proposed in this work consists of two cascaded off-axis holograms in combination with a micro lens array, and three types of PV cells. An aspherical lens design is made to minimize the dispersion so that higher concentration ratios can be achieved for a three-junction system. An analysis methodology is also developed to determine the optical efficiency of the resulting system, the characteristics of the dispersed spectrum, and the overall system conversion efficiency for a combination of three types of PV cells.

  6. Kauai Island Utility Co-op (KIUC) PV integration study.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Mousseau, Tom (Knoxville, TN)

    2011-08-01

    This report investigates the effects that increased distributed photovoltaic (PV) generation would have on the Kauai Island Utility Co-op (KIUC) system operating requirements. The study focused on determining reserve requirements needed to mitigate the impact of PV variability on system frequency, and the impact on operating costs. Scenarios of 5-MW, 10-MW, and 15-MW nameplate capacity of PV generation plants distributed across the Kauai Island were considered in this study. The analysis required synthesis of the PV solar resource data and modeling of the KIUC system inertia. Based on the results, some findings and conclusions could be drawn, including that the selection of units identified as marginal resources that are used for load following will change; PV penetration will displace energy generated by existing conventional units, thus reducing overall fuel consumption; PV penetration at any deployment level is not likely to reduce system peak load; and increasing PV penetration has little effect on load-following reserves. The study was performed by EnerNex under contract from Sandia National Laboratories with cooperation from KIUC.

  7. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu;

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module’s...... impedance spectrum, and further construct an impedance model that can link environmental changes to the model’s parameters. To achieve this, an optimized setup has been developed for long-term impedance spectra monitoring synchronised with accurate irradiance and temperature data. Preliminary results show...

  8. PV Validation and Bankability Workshop: San Jose, California

    Energy Technology Data Exchange (ETDEWEB)

    Granata, J.; Howard, J.

    2011-12-01

    This report is a collaboration between Sandia National Laboratories, the National Renewable Energy Laboratory, and the Florida Solar Energy Center (FSEC). The report provides feedback from the U.S. Department of Energy's (DOE) Solar Program PV Validation and Bankability Workshop in San Jose, California on August 31, 2011. It focuses on the current state of PV in the United States, private funding to fund U.S. PV industry growth, roles and functions of the regional test center program, and ways to improve the current validation and bankability practices.

  9. PV Project Finance in the United States, 2016

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, David; Lowder, Travis; Schwabe, Paul

    2016-09-01

    This brief is a compilation of data points and market insights that reflect the state of the project finance market for solar photovoltaic (PV) assets in the United States as of the third quarter of 2016. This information can generally be used as a simplified benchmark of the costs associated with securing financing for solar PV as well as the cost of the financing itself (i.e., the cost of capital). Three sources of capital are considered -- tax equity, sponsor equity, and debt -- across three segments of the PV marketplace.

  10. Monitoring and Analysis of Two Grid Connected PV Systems

    OpenAIRE

    2013-01-01

    International audience; In this paper, two grid connected photovoltaic systems are studied and monitored for fault detection ad predictive reliability. The first PV grid, is at CNRS-PROMES laboratory in Perpignan, built in 2001 with 3 PV arrays named "Shed","Brise soleil","Mur rideau") connected to the grid thanks to many inverter of different power (3 of 4KWC and 2 of 2.5KWC). The second one is at CNRS-LAAS in Toulouse with a power of 100kWc. It is composed of a facade of 36kWc PV array and ...

  11. CPV Vs. PV from a grid-matching perspective

    Science.gov (United States)

    Strobach, E.; Bader, S.; Faiman, D.; Solomon, A. A.; Meron, G.

    2012-10-01

    In a recently-published series of papers we studied the general problem of matching large PV systems of various kinds to the electricity grid. In those studies CPV systems were simulated via an artificial ansatz in which they were treated as 2-axis flat-panel PV systems whose light sensitivity is only to the direct normal component (DNI) of solar irradiance. The present study replaces this ansatz with an experimentally validated model of a real CPV system. We compare a genuine 2-axis high-concentration CPV system with a static flat-panel PV system from the standpoint of matching both system types to the Israeli electricity grid.

  12. Power Electronic System for Multi-MW PV sites

    DEFF Research Database (Denmark)

    Paasch, Kasper

    The work presented in this thesis addresses the optimization potential of large PV power plants with respect to energy production during periods of moving clouds. Presently the number and size of utility scale Photo Voltaic (PV) power plants in the megawatt range is increasing and the market...... of energy is in the range ... for field use, is battery operated and has been applied for the characterization of a solar panel over a period of 6 months at the ESTER Outdoor PV monitoring station in Rome, Italy....

  13. Design of a Solar Tracker System for PV Power Plants

    Directory of Open Access Journals (Sweden)

    Tiberiu Tudorache

    2010-04-01

    Full Text Available This paper deals with the design and execution of a solar tracker systemdedicated to the PV conversion panels. The proposed single axis solar tracker deviceensures the optimization of the conversion of solar energy into electricity by properlyorienting the PV panel in accordance with the real position of the sun. The operation of theexperimental model of the device is based on a DC motor intelligently controlled by adedicated drive unit that moves a mini PV panel according to the signals received from twosimple but efficient light sensors. The performance and characteristics of the solar trackerare experimentally analyzed.

  14. Measures for diffusion of solar PV in selected African countries

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Hansen, Ulrich Elmer; Mackenzie, Gordon A.;

    2015-01-01

    This paper investigates how African governments are considering supporting and promoting the diffusion of solar PV. This issue is explored by examining so-called ‘technology action plans (TAPs)’, which were main outputs of the Technology Needs Assessment project implemented in 10 African countries...... that governments’ strategies to promoting solar PV are moving from isolated projects towards frameworks for market development and that there are high expectations to upgrading in the PV value chain through local assembly of panels and local production of other system elements. Commonly identified measures include...... support to: local production; financing schemes; tax exemptions; establishment and reinforcement of standards; technical training; and research and development....

  15. Population genomic insights into variation and evolution of Xanthomonas oryzae pv. oryzae

    Science.gov (United States)

    Midha, Samriti; Bansal, Kanika; Kumar, Sanjeet; Girija, Anil Madhusoodana; Mishra, Deo; Brahma, Kranthi; Laha, Gouri Sankar; Sundaram, Raman Meenakshi; Sonti, Ramesh V.; Patil, Prabhu B.

    2017-01-01

    Xanthomonas oryzae pv. oryzae ( Xoo) is a serious pathogen of rice causing bacterial leaf blight disease. Resistant varieties and breeding programs are being hampered by the emergence of highly virulent strains. Herein we report population based whole genome sequencing and analysis of 100 Xoo strains from India. Phylogenomic analysis revealed the clustering of Xoo strains from India along with other Asian strains, distinct from African and US Xo strains. The Indian Xoo population consists of a major clonal lineage and four minor but highly diverse lineages. Interestingly, the variant alleles, gene clusters and highly pathogenic strains are primarily restricted to minor lineages L-II to L-V and in particularly to lineage L-III. We could also find the association of an expanded CRISPR cassette and a highly variant LPS gene cluster with the dominant lineage. Molecular dating revealed that the major lineage, L-I is youngest and of recent origin compared to remaining minor lineages that seems to have originated much earlier in the past. Further, we were also able to identify core effector genes that may be helpful in efforts towards building durable resistance against this pathogen. PMID:28084432

  16. Erwinia oleae sp. nov., isolated from olive knots caused by Pseudomonas savastanoi pv. savastanoi.

    Science.gov (United States)

    Moretti, Chiaraluce; Hosni, Taha; Vandemeulebroecke, Katrien; Brady, Carrie; De Vos, Paul; Buonaurio, Roberto; Cleenwerck, Ilse

    2011-11-01

    Three endophytic bacterial isolates were obtained in Italy from olive knots caused by Pseudomonas savastanoi pv. savastanoi. Phenotypic tests in combination with 16S rRNA gene sequence analysis indicated a phylogenetic position for these isolates in the genera Erwinia or Pantoea, and revealed two other strains with highly similar 16S rRNA gene sequences (>99 %), CECT 5262 and CECT 5264, obtained in Spain from olive knots. Rep-PCR DNA fingerprinting of the five strains from olive knots with BOX, ERIC and REP primers revealed three groups of profiles that were highly similar to each other. Multilocus sequence analysis (MLSA) based on concatenated partial atpD, gyrB, infB and rpoB gene sequences indicated that the strains constituted a single novel species in the genus Erwinia. The strains showed general phenotypic characteristics typical of the genus Erwinia and whole genome DNA-DNA hybridization data confirmed that they represented a single novel species of the genus Erwinia. The strains showed DNA G+C contents ranging from 54.7 to 54.9 mol%. They could be discriminated from phylogenetically related species of the genus Erwinia by their ability to utilize potassium gluconate, l-rhamnose and d-arabitol, but not glycerol, inositol or d-sorbitol. The name Erwinia oleae sp. nov. (type strain DAPP-PG 531(T)= LMG 25322(T) = DSM 23398(T)) is proposed for this novel taxon.

  17. Pathogenic Interactions Between Xanthomonas axonopodis pv. citri and Cultivars of Pummelo (Citrus grandis).

    Science.gov (United States)

    Shiotani, H; Ozaki, K; Tsuyumu, S

    2000-12-01

    ABSTRACT The aggressiveness of strains of Xanthomonas axonopodis pv. citri on seven Citrus species, including Citrus sinensis (navel orange), C. paradisi (grapefruit), C. unshiu (Satsuma mandarin), C. junos (Yuzu), C. aurantifolia ('Mexican' lime), C. tachibana (Tachibana), and C. grandis (pummelo: 'Otachibana', 'Banpeiyu', and 'Anseikan'), were assessed by comparing lesion expansion and growth in planta, using a prick inoculation method. The existence of two groups distinct in aggressiveness was demonstrated on the pummelo cultivars, whereas the remaining species tested were uniformly susceptible. The two groups of strains were distinct in lesion expansion and growth in planta; however, both caused canker lesions on the 'Otachibana' pummelo. The sensitivity of the bacterial strains to phages Cp1 and Cp2 was associated with differences in aggressiveness. Namely, all the strains sensitive to Cp2 but resistant to Cp1 were aggressive to 'Otachibana', whereas all the strains sensitive to Cp1 but resistant to Cp2 were weakly aggressive. When a repetitive sequence-based polymerase chain reaction amplification was carried out by enterobacterial repetitive intergeneric consensus (ERIC) sequences (ERIC1R and ERIC2) as the primers, these two groups were also distinguishable by the presence or absence of a 1.8-kb DNA fragment among otherwise identical fragments. The 1.8-kb fragment was amplified only from the strains aggressive to C. grandis.

  18. Antimicrobial Effects of a Hexapetide KCM21 against Pseudomonas syringae pv. tomato DC3000 and Clavibacter michiganensis subsp. michiganensis

    Directory of Open Access Journals (Sweden)

    Jeahyuk Choi

    2014-09-01

    Full Text Available Antimicrobial peptides (AMPs are small but effective cationic peptides with variable length. In previous study, four hexapeptides were identified that showed antimicrobial activities against various phytopathogenic bacteria. KCM21, the most effective antimicrobial peptide, was selected for further analysis to understand its modes of action by monitoring inhibitory effects of various cations, time-dependent antimicrobial kinetics, and observing cell disruption by electron microscopy. The effects of KCM21 on Gram-negative strain, Pseudomonas syringae pv. tomato DC3000 and Gram-positive strain, Clavibacter michiganensis subsp. michiganensis were compared. Treatment with divalent cations such as Ca²⁺ and Mg²⁺ inhibited the bactericidal activities of KCM21 significantly against P. syringae pv. tomato DC3000. The bactericidal kinetic study showed that KCM21 killed both bacteria rapidly and the process was faster against C. michiganensis subsp. michiganensis. The electron microscopic analysis revealed that KCM21 induced the formation of micelles and blebs on the surface of P. syringae pv. tomato DC3000 cells, while it caused cell rupture against C. michiganensis subsp. michiganensis cells. The outer membrane alteration and higher sensitivity to Ca²⁺ suggest that KCM21 interact with the outer membrane of P. syringae pv. tomato DC3000 cells during the process of killing, but not with C. michiganensis subsp. michiganensis cells that lack outer membrane. Considering that both strains had similar sensitivity to KCM21 in LB medium, outer membrane could not be the main target of KCM21, instead common compartments such as cytoplasmic membrane or internal macromolecules might be a possible target(s of KCM21.

  19. Antimicrobial Effects of a Hexapetide KCM21 against Pseudomonas syringae pv. tomato DC3000 and Clavibacter michiganensis subsp. michiganensis.

    Science.gov (United States)

    Choi, Jeahyuk; Baek, Kwang-Hyun; Moon, Eunpyo

    2014-09-01

    Antimicrobial peptides (AMPs) are small but effective cationic peptides with variable length. In previous study, four hexapeptides were identified that showed antimicrobial activities against various phytopathogenic bacteria. KCM21, the most effective antimicrobial peptide, was selected for further analysis to understand its modes of action by monitoring inhibitory effects of various cations, time-dependent antimicrobial kinetics, and observing cell disruption by electron microscopy. The effects of KCM21 on Gram-negative strain, Pseudomonas syringae pv. tomato DC3000 and Gram-positive strain, Clavibacter michiganensis subsp. michiganensis were compared. Treatment with divalent cations such as Ca(2+) and Mg(2+) inhibited the bactericidal activities of KCM21 significantly against P. syringae pv. tomato DC3000. The bactericidal kinetic study showed that KCM21 killed both bacteria rapidly and the process was faster against C. michiganensis subsp. michiganensis. The electron microscopic analysis revealed that KCM21 induced the formation of micelles and blebs on the surface of P. syringae pv. tomato DC3000 cells, while it caused cell rupture against C. michiganensis subsp. michiganensis cells. The outer membrane alteration and higher sensitivity to Ca(2+) suggest that KCM21 interact with the outer membrane of P. syringae pv. tomato DC3000 cells during the process of killing, but not with C. michiganensis subsp. michiganensis cells that lack outer membrane. Considering that both strains had similar sensitivity to KCM21 in LB medium, outer membrane could not be the main target of KCM21, instead common compartments such as cytoplasmic membrane or internal macromolecules might be a possible target(s) of KCM21.

  20. The stealth episome: suppression of gene expression on the excised genomic island PPHGI-1 from Pseudomonas syringae pv. phaseolicola.

    Directory of Open Access Journals (Sweden)

    Scott A C Godfrey

    2011-03-01

    Full Text Available Pseudomonas syringae pv. phaseolicola is the causative agent of halo blight in the common bean, Phaseolus vulgaris. P. syringae pv. phaseolicola race 4 strain 1302A contains the avirulence gene avrPphB (syn. hopAR1, which resides on PPHGI-1, a 106 kb genomic island. Loss of PPHGI-1 from P. syringae pv. phaseolicola 1302A following exposure to the hypersensitive resistance response (HR leads to the evolution of strains with altered virulence. Here we have used fluorescent protein reporter systems to gain insight into the mobility of PPHGI-1. Confocal imaging of dual-labelled P. syringae pv. phaseolicola 1302A strain, F532 (dsRFP in chromosome and eGFP in PPHGI-1, revealed loss of PPHGI-1::eGFP encoded fluorescence during plant infection and when grown in vitro on extracted leaf apoplastic fluids. Fluorescence-activated cell sorting (FACS of fluorescent and non-fluorescent PPHGI-1::eGFP F532 populations showed that cells lost fluorescence not only when the GI was deleted, but also when it had excised and was present as a circular episome. In addition to reduced expression of eGFP, quantitative PCR on sub-populations separated by FACS showed that transcription of other genes on PPHGI-1 (avrPphB and xerC was also greatly reduced in F532 cells harbouring the excised PPHGI-1::eGFP episome. Our results show how virulence determinants located on mobile pathogenicity islands may be hidden from detection by host surveillance systems through the suppression of gene expression in the episomal state.

  1. Characterisation of the mgo operon in Pseudomonas syringae pv. syringae UMAF0158 that is required for mangotoxin production

    Directory of Open Access Journals (Sweden)

    Arrebola Eva

    2012-01-01

    Full Text Available Abstract Background Mangotoxin is an antimetabolite toxin that is produced by strains of Pseudomonas syringae pv. syringae; mangotoxin-producing strains are primarily isolated from mango tissues with symptoms of bacterial apical necrosis. The toxin is an oligopeptide that inhibits ornithine N-acetyl transferase (OAT, a key enzyme in the biosynthetic pathway of the essential amino acids ornithine and arginine. The involvement of a putative nonribosomal peptide synthetase gene (mgoA in mangotoxin production and virulence has been reported. Results In the present study, we performed a RT-PCR analysis, insertional inactivation mutagenesis, a promoter expression analysis and terminator localisation to study the gene cluster containing the mgoA gene. Additionally, we evaluated the importance of mgoC, mgoA and mgoD in mangotoxin production. A sequence analysis revealed an operon-like organisation. A promoter sequence was located upstream of the mgoB gene and was found to drive lacZ transcription. Two terminators were located downstream of the mgoD gene. RT-PCR experiments indicated that the four genes (mgoBCAD constitute a transcriptional unit. This operon is similar in genetic organisation to those in the three other P. syringae pathovars for which complete genomes are available (P. syringae pv. syringae B728a, P. syringae pv. tomato DC3000 and P. syringae pv. phaseolicola 1448A. Interestingly, none of these three reference strains is capable of producing mangotoxin. Additionally, extract complementation resulted in a recovery of mangotoxin production when the defective mutant was complemented with wild-type extracts. Conclusions The results of this study confirm that mgoB, mgoC, mgoA and mgoD function as a transcriptional unit and operon. While this operon is composed of four genes, only the last three are directly involved in mangotoxin production.

  2. A comparison of design features of 80 pv-powered products

    NARCIS (Netherlands)

    Apostolou, G.; Reinders, A.H.M.E.

    2012-01-01

    In this paper 80 commercially available PV products have been analysed. The data set comprises 46 low power PV products in the range of 0 to 17 Wp and 34 PV products with a power of 17 Wp up to 27 kWp. The goal of our study is to investigate and evaluate features of PV products that are available on

  3. Robustness analysis of the efficiency in PV inverters

    DEFF Research Database (Denmark)

    Pigazo, Alberto; Liserre, Marco; Blaabjerg, Frede;

    2013-01-01

    During last years an increasing attention has been paid to the efficiency of grid-connected PV inverters. They are manufactured from a number of discrete components and by using a certain topology and control strategy. Hence, the performance of a certain PV inverter not only depends on the selected...... topology and control strategy but also on the characteristics of the employed components. The aim of this paper is evaluate the effect of physical variations associated to the main components on the overall efficiency of PV inverters. It is concluded that a statistical evaluation of the power converter...... provides a better understanding of the PV inverter performance and, in this sense, the definition of the European Efficiency must be reviewed in order to show the quality of the manufactured product....

  4. Heritage plaza parking lots improvement project- Solar PV installation

    Energy Technology Data Exchange (ETDEWEB)

    Hooks, Todd [Agua Caliente Indian Reservation, Palm Springs, CA (United States)

    2017-03-31

    The Agua Caliente Band of Cahuilla Indians (ACBCI or the “Tribe”) installed a 79.95 kW solar photovoltaic (PV) system to offset the energy usage costs of the Tribal Education and Family Services offices located at the Tribe's Heritage Plaza office building, 90I Tahquitz Way, Palm Springs, CA, 92262 (the "Project"). The installation of the Solar PV system was part of the larger Heritage Plaza Parking Lot Improvements Project and mounted on the two southern carport shade structures. The solar PV system will offset 99% of the approximately 115,000 kWh in electricity delivered annually by Southern California Edison (SCE) to the Tribal Education and Family Services offices at Heritage Plaza, reducing their annual energy costs from approximately $22,000 annually to approximately $200. The total cost of the proposed solar PV system is $240,000.

  5. Retaining the Value of PV at High Penetration Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah; Bolen, Michael

    2016-10-13

    PV prices have dropped and are now attractive without incentives for peaking applications in some locations. Modeling suggests and, empirically, some regions demonstrate that as PV penetration increases its value decreases, predominantly due to a decrease in energy and capacity value. It is not apparent what technologies and price may be needed for PV to supply tens of percent of electricity in the most economically efficient manner. A 1-day workshop was co-sponsored by EPRI and NREL with support from ASU. A dozen presentations and discussions introduced how the interplay of various technologies impact the value of PV, identified technical challenges and gaps impeding implementation, and discussed future R&D needs and opportunities.

  6. Measures for diffusion of solar PV in selected African countries

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Hansen, Ulrich Elmer; Mackenzie, Gordon A.

    2017-01-01

    that governments’ strategies to promoting solar PV are moving from isolated projects towards frameworks for market development and that there are high expectations to upgrading in the PV value chain through local assembly of panels and local production of other system elements. Commonly identified measures include......This paper investigates how African governments are considering supporting and promoting the diffusion of solar PV. This issue is explored by examining so-called ‘technology action plans (TAPs)’, which were main outputs of the Technology Needs Assessment project implemented in 10 African countries...... from 2010 to 2013. The paper provides a review of three distinct but characteristic trajectories for PV market development in Kenya (private-led market for solar home systems), Morocco (utility-led fee-for service model) and Rwanda (donorled market for institutional systems). The paper finds...

  7. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  8. Design Considerations for Stand-Alone Photovoltaic (PV Cell Applications

    Directory of Open Access Journals (Sweden)

    Mehmet Cebeci

    2013-06-01

    Full Text Available Solar energy is one of the most important renewable energy sources. The photovoltaic (PV cell systems are used to convert solar energy into electricity. PV systems are divided into two as fixed systems and tracking systems. Fixed systems are mounted at a certain tilt with horizontal to make full use of sunlight. The tilt angle of PV arrays in a fixed system depends on the location and time. If this tilt angle is determined well, the amount of insolation and the energy that is generated increases. When a stand-alone PV cell system is being chosen, certain design operations should be implemented. The number of modules and batteries needed for any system should be calculated by means of the amount of load, insolation level, module characteristics, etc. The design of system is finalized according to the energy demand.

  9. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented....... The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter....

  10. Angle Resolved Performance Measurements on PV Glass and Modules

    DEFF Research Database (Denmark)

    Juutilainen, Line Tollund; Thorsteinsson, Sune; Poulsen, Peter Behrensdorff

    2016-01-01

    the concept of PV balconies as cost efficient and easy way of integrating PV into buildings. The experimental work consists of the fabrication of single cell mini modules with different glass covering, and characterizing their angular response in a custom made setup, where only the direct sunlight is used......The angular response of PV-modules has significant impact on the energy production. This is especially pronounced in BIPV where installation angles often are far from optimal. Nevertheless, a gain in energy yield may be obtained by choosing a proper glass as superstrate. In this work we present...... as a light source. As a special case we estimate the annual yield for each glass in the case of PV balconies for a specific geographical location and orientation of the module....

  11. PV GRID Advisory Paper. Consultation version: key recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Bianca; Concas, Giorgia; Cossent, Rafael; Franz, Oliver; Frias, Pablo; Hermes, Roland; Lama, Riccardo; Loew, Holger; Mateo, Carlos; Rekinger, Manoel; Sonvilla, Paolo Michele; Vandenbergh, Michel

    2014-01-15

    PV GRID is a transnational collaborative effort under the umbrella of the Intelligent Energy Europe programme. The main project goal is to enhance photovoltaic (PV) hosting capacity in distribution grids while overcoming regulatory and normative barriers hampering the application of available technical solutions. The European PV GRID advisory paper aims at providing an overview of the issues and barriers that need to be addressed in order to enhance the distribution grid hosting capacity for PV and other distributed generation (DG).To this purpose, barriers are classified as either cross-cutting challenges or specific barriers, depending on whether they have an overarching, system-wide character or rather focus on one single issue such as curtailment, self-consumption or storage. Finally, a set of preliminary recommendations on how to overcome these issues is presented, allowing for the implementation of the identified technical solutions.

  12. Promotional drivers for grid-connected PV

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Polo, A.; Hass, R.; Suna, D.

    2009-03-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at promotional measures for grid-connected photovoltaic systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the core objective of this study which was to analyse the success of various governmental regulatory programs and governmental and non-governmental marketing programs for grid-connected PV systems. To meet this objective, a review of the most important past and current programs around the world was conducted. The theoretical bases of supply and demand are explained and the types of existing strategies are documented in a second Section. In Chapter 3, various programs around the world are described. Chapter 4 focuses on defining success criteria which will be used for the analysis of the programs. Finally, the major conclusions drawn complete this analysis.

  13. The Ramakrishna Mission economic PV development initiative

    Energy Technology Data Exchange (ETDEWEB)

    Stone, J.L.; Ullal, H.S. [National Renewable Energy Lab., Golden, CO (United States); Sherring, C. [Sherring Energy Associates, Princeton, NJ (United States)

    1998-09-01

    India is the world`s second most populous country, quickly approaching one billion persons. Although it has a well-developed electricity grid, many of the people have little or no access to electricity and all of the benefits associated with it. There are areas that are isolated from the grid and will not be connected for many years, if ever. One such area is the Sundarbans located in the delta region of the two great rivers, the Ganges and Brahmaputra, partially in India and partially in Bangladesh. It is estimated that 1.5 million people live in this area, crisscrossed by many islands and rivers, who have only marginal supplies of electricity generated primarily from diesel generators and batteries. Working with the regional non-governmental organization (NGO), the Ramakrishna Mission, and the West Bengal Renewable Energy Development Agency, the governments of India and the US initiated a rural electrification initiative to demonstrate the economic and technical feasibility of photovoltaics to provide limited supplies of electricity for such applications as solar home lighting systems (SHS), water pumping, vaccine refrigeration, communications, and economic development activities. This paper details initial results from approximately 30 kilowatts of PV systems installed in the area, including socio-economic impacts and technical performance.

  14. Evaluation of PV Module Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, John; Silverman, Timothy; Miller, David C.; McNutt, Peter; Kempe, Michael; Deceglie, Michael

    2015-06-14

    This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

  15. Performance and Degradation Analysis of Operating PV Systems

    Science.gov (United States)

    Da Silva Freire, Felipe

    The environmental concerns together with the decrease in technology cost lead the solar market to growth rapidly along the last decade. The photovoltaic (PV) systems are one of the solar energy alternatives and the silicon solar cells are currently the most widespread technology. Photovoltaic (PV) modules are considered the most reliable component of a photovoltaic system. The reliability and lifetime depends on the modules energy conversion performance and degradation modes. The analysis of monitoring data give insights about the PV system performance along its service time. The comparison between this data and mathematical models configure a way to predict the futures and new PV installations performance. The goal of this study is to understand the PV systems performance and degradation along its lifetime. A mathematical model was employed to predict the power output of a real, relatively new operating PV system with respect to environmental parameters temperature, irradiance and cloud coverage. The model used is based on one diode ideality factor and takes into account the parasitic series resistance. The results have been compared with the actual PV output data collected for the year 2014 and show good correlation. As the model predicts the system power output assuming the system in new conditions, the deviation in performance of the real data in comparison to the modeling results need to be further investigated for systems in service for longer time. For this propose, the study presents a condensed review of various causes of degradation in silicon PV modules and techniques to observe and investigate these degradation mechanisms. Major effects on output performance exhibit increase in observed ideality factor n2 and recombination current J02 primarily caused by decrease in minority carrier lifetime, shunts and increase in series resistance. The study further, investigates the governing degradation modes on a ten years old PV crystalline silicon module

  16. Towards a PV-θ view of the general circulation

    Science.gov (United States)

    Hoskins, Brian J.

    1991-09-01

    In recent years, there has been a resurgence of interest in using isentropic coordinates and Rossby-Ertel potential vorticity (PV) for diagnosing the behaviour of middle latitude synoptic systems. Such a PV-θ analysis may also prove important in providing insight into the global circulation of the atmosphere. Apart from the isentropic diagnostic of D. Johnson and collaborators, some quasi-geostrophic studies and recent studies of stratospheric behaviour, there has been little work in this area and our present understanding is very limited. The object of the present paper is to stimulate such studies by presenting some initial results from continuing research. A three-fold division of the atmosphere is discussed. The "Overworld" is the region encompassed by isentropic surfaces that are everywhere above the tropopause. In the "Middleworld", the region with isentropes crossing the tropopause but not striking the Earth's surface, the isentropic zonal and time mean of PV exhibits interesting regions of enhanced and diminished gradients. The isentropic transient eddy advection of PV exhibits a dipolar distribution about the tropopause, suggestive of PV mixing. The marked PV signature of the Asian summer monsoon on one particular Middleworld isentrope is shown and the mean isentropic advection of PV shows interesting features. For the "Underworld", in which isentropic surfaces intercept the surface of the Earth, a PV-θ analysis yields a novel constraint linking low-level drag and diabatic heating. This constraint links "westerlies" and "cooling", and "easterlies" and "heating" in some average sense. The result is discussed in terms of the Southern Hemisphere strong surface westerlies and the circulation associated with the Asian summer and winter monsoons.

  17. Microgrid-Ready Solar PV; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-07-01

    Designing new solar projects to be 'microgrid-ready' enables the U.S. DoD, other federal agencies, and the private sector to plan future microgrid initiatives to utilize solar PV as a generating resource. This fact sheet provides background information with suggested language for several up-front considerations that can be added to a solar project procurement or request for proposal (RFP) that will help ensure that PV systems are built for future microgrid connection.

  18. PV on existing roofs. Experiences of sixty households

    Energy Technology Data Exchange (ETDEWEB)

    Kaan, H.F.; Van Dijk, A.L.; Van Leeuwen, M. [ECN Renewable Energy in the Built Environment DEGO, Petten (Netherlands)

    2001-05-01

    In order to stimulate the use of PV (photovoltaic energy) in the Netherlands, the Dutch government offers a subsidy of 3.40 Euro per Watt peak installed after January 2001. It is hoped that this will facilitate the market for PV systems. The newly to be build houses form a substantial potential as PV carriers, but the existing housing stock is much larger. PV on existing houses has been promoted for several years now in the Netherlands, amongst others by utilities, PV manufacturers and the environmental organization Greenpeace. The new subsidy scheme will undoubtedly have a large impact on the PV demand for existing houses. However, it is doubtful whether the technology is mature enough to meet a large scale demand. In order to learn from experiences with small scale PV systems on roofs of existing houses, the Energy research Centre of the Netherlands (ECN) has set up a research project in which participating employees give access to the roofs of their houses to install PV systems. Fifty-nine ECN employees entered for participation in this project. This group provides a random selection of roofs, so that many different types of roof integration can be examined. Subjects included in the project investigations are: constructional aspects, yield and reliability of systems, institutional aspects such as getting building permits, aesthetics, behavioural aspects. The project was set up in 2000. In April 2001, the installation had been monitored and evaluated. Also the preparatory and initial findings and experiences of project participants have been registered through a questionnaire. The yield of the modules is registered by the participants.

  19. Solar PV Energy Conversion System and its Configurations

    Directory of Open Access Journals (Sweden)

    Ahteshamul Haque

    2016-02-01

    Full Text Available Solar PV based energy conversion system is now used in commercial and residential buildings. Advancements in Power electronics leads the researchers to enhance the use of solar application in various configurations. These configurations may be used to utilize the energy optimally. The main objective of this paper is to present an overview of the various configurations of solar PV energy conversion system

  20. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T system against conventional photovoltaic (PV system

    Directory of Open Access Journals (Sweden)

    Peng Xu

    2015-11-01

    Full Text Available Photovoltaic (PV semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the overall field system involved 15 stand-alone PV panels and 15 retrofitted PV/T panels. The laboratory testing results demonstrated the PV/T panel could achieve the electrical efficiency of about 16.8% (relatively 5% improvement comparing with the stand-alone PV panel, and yield an extra amount of heat with thermal efficiency of nearly 65%. The field testing results indicated that the hybrid PV/T panel could enhance the electrical return of PV panels by nearly 3.5%, and increase the overall energy output by nearly 324.3%. Further opportunities and challenges were then discussed from aspects of different PV/T stakeholders to accelerate the development. It is expected that such technology could become a significant solution to yield more electricity, offset heating load freely and reduce carbon footprint in contemporary energy environment.

  1. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  2. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  3. Identification of Pathotypes of Xanthomonas axonopodis pv. manihotis in Africa and Detection of Quantitative Trait Loci and Markers for Resistance to Bacterial Blight of Cassava.

    Science.gov (United States)

    Wydra, K; Zinsou, V; Jorge, V; Verdier, V

    2004-10-01

    ABSTRACT Cassava suffers from bacterial blight attack in all growing regions. Control by resistance is unstable due to high genotype-environment interactions. Identifying genes for resistance to African strains of Xanthomonas axonopodis pv. manihotis can support breeding efforts. Five F(1) cassava genotypes deriving from the male parent 'CM2177-2' and the female parent 'TMS30572' were used to produce 111 individuals by backcrossing to the female parent. In all, 16 genotypes among the mapping population were resistant to stem inoculation by four strains of X. axonopodis pv. manihotis from different locations in Africa, and 19 groups with differential reactions to the four strains were identified, suggesting that the strains represent different pathotypes. Four genotypes were resistant to leaf inoculation, and three were resistant to both stem and leaf inoculations. Genotypes with susceptible, moderately resistant, and resistant reactions after leaf and stem inoculation partly differed in their reactions on leaves and stems. Based on the genetic map of cassava, single-markeranalysis of disease severity after stem-puncture inoculation was performed. Eleven markers were identified, explaining between 16 and 33.3% of phenotypic variance of area under disease progress curve. Five markers on three and one linkage groups from the female- and male-derived framework of family CM8820, respectively, seem to be weakly associated with resistance to four strains of X. axonopodis pv. manihotis. Based on the segregation of alleles from the female of family CM8873, one marker was significantly associated with resistance to two X. axonopodis pv. manihotis strains, GSPB2506 and GSPB2511, whereas five markers were not linked to any linkage group. The quantitative trait loci (QTL) mapping results also suggest that the four African strains belong to four different pathotypes. The identified pathotypes should be useful for screening for resistance, and the QTL and markers will support

  4. Design optimization of transformerless grid-connected PV inverters including reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost Of the Ele......This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost...... to the non-optimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  5. Continuing Developments in PV Risk Management: Strategies, Solutions, and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Lowder, T.; Mendelsohn, M.; Speer, B.; Hill, R.

    2013-02-01

    As the PV industry matures, successful risk management practices will become more imperative to ensure investor confidence, control costs, and facilitate further growth. This report discusses several key aspects of risk management during the commercial- and utility-scale project life cycle, from identification of risks, to the process of mitigating and allocating those risks among project parties, to transferring those risks through insurance. The report also explores novel techniques in PV risk management, options to offload risks onto the capital markets, and innovative insurance policies (namely warranty policies) that address risks unique to the PV sector. One of the major justifications for robust risk management in the PV industry is the cost-reduction opportunities it affords. If the PV industry can demonstrate the capability to successfully manage its risks, thereby inspiring confidence in financiers, it may be able to obtain a lower cost of capital in future transactions. A lower cost of capital translates to a lower cost of energy, which will in turn enhance PV?s competitiveness at a time when it will have to rely less on subsidies to support its market penetration.

  6. Integrating High Penetrations of PV into Southern California

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, B.; Mather, B.; Hasper-Tuttle, J.; Neal, R.; Katiraei, F.; Yazdani, A.; Aguero, J. R.; Hoff, T. E.; Norris, B. L.; Parkins, A.; Seguin, R.; Schauder, C.

    2011-01-01

    California regulators recently approved a plan proposed by Southern California Edison (SCE) to install 500 MW of distributed photovoltaic (PV) energy in its utility service territory over the next 5 years. The installations will include 250 MW of utility-owned solar and 250 MW of independently owned solar. SCE expects that the majority of these systems will be commercial-scale rooftop PV systems connected at various points in the distribution system. Each of the SCE rooftop PV systems will typically have a rating of 1-3 MW. To understand the impact of high-penetration PV on the distribution grid, the National Renewable Energy Laboratory (NREL) and SCE brought together a team of experts in resource assessment, distribution modeling, and planning to help analyze the impacts of adding high penetration of PV into the distribution system. Through modeling and simulation, laboratory testing, and field demonstrations, the team will address the issues identified in the analysis by fully examining the challenges, developing solutions, and transitioning those solutions to the field for large-scale deployment. This paper gives an update on the project and discusses technical results of integrating a large number of distributed PV systems into the grid.

  7. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  8. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  9. Review of PV Inverter Technology Cost and Performance Projections

    Energy Technology Data Exchange (ETDEWEB)

    Navigant Consulting Inc.

    2006-01-01

    The National Renewable Energy Laboratory (NREL) has a major responsibility in the implementation of the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program. Sandia National Laboratories (SNL) has a major role in supporting inverter development, characterization, standards, certifications, and verifications. The Solar Energy Technologies Program recently published a Multiyear Technical Plan, which establishes a goal of reducing the Levelized Energy Cost (LEC) for photovoltaic (PV) systems to $0.06/kWh by 2020. The Multiyear Technical Plan estimates that, in order to meet the PV system goal, PV inverter prices will need to decline to $0.25-0.30 Wp by 2020. DOE determined the need to conduct a rigorous review of the PV Program's technical and economic targets, including the target set for PV inverters. NREL requested that Navigant Consulting Inc.(NCI) conduct a review of historical and projected cost and performance improvements for PV inverters, including identification of critical barriers identified and the approaches government might use to address them.

  10. Battery Energy Storage System for PV Output Power Leveling

    Directory of Open Access Journals (Sweden)

    Rajkiran Singh

    2014-01-01

    Full Text Available Fluctuating photovoltaic (PV output power reduces the reliability in power system when there is a massive penetration of PV generators. Energy storage systems that are connected to the PV generators using bidirectional isolated dc-dc converter can be utilized for compensating the fluctuating PV power. This paper presents a grid connected energy storage system based on a 2 kW full-bridge bidirectional isolated dc-dc converter and a PWM converter for PV output power leveling. This paper proposes two controllers: a current controller using the d-q synchronous reference and a phase-shift controller. The main function of the current controller is to regulate the voltage at the high-side dc, so that the voltage ratio of the high-voltage side (HVS with low-voltage side (LVS is equal to the transformer turns ratio. The phase-shift controller is employed to manage the charging and discharging modes of the battery based on PV output power and battery voltage. With the proposed system, unity power factor and efficient active power injection are achieved. The feasibility of the proposed control system is investigated using PSCAD simulation.

  11. Residential Solar PV Systems in the Carolinas: Opportunities and Outcomes.

    Science.gov (United States)

    Alqahtani, Bandar Jubran; Holt, Kyra Moore; Patiño-Echeverri, Dalia; Pratson, Lincoln

    2016-02-16

    This paper presents a first-order analysis of the feasibility and technical, environmental, and economic effects of large levels of solar photovoltaic (PV) penetration within the services areas of the Duke Energy Carolinas (DEC) and Duke Energy Progress (DEP). A PV production model based on household density and a gridded hourly global horizontal irradiance data set simulates hourly PV power output from roof-top installations, while a unit commitment and real-time economic dispatch (UC-ED) model simulates hourly system operations. We find that the large generating capacity of base-load nuclear power plants (NPPs) without ramping capability in the region limits PV integration levels to 5.3% (6510 MW) of 2015 generation. Enabling ramping capability for NPPs would raise the limit of PV penetration to near 9% of electricity generated. If the planned retirement of coal-fired power plants together with new installations and upgrades of natural gas and nuclear plants materialize in 2025, and if NPPs operate flexibly, then the share of coal-fired electricity will be reduced from 37% to 22%. A 9% penetration of electricity from PV would further reduce the share of coal-fired electricity by 4-6% resulting in a system-wide CO2 emissions rate of 0.33 to 0.40 tons/MWh and associated abatement costs of 225-415 (2015$ per ton).

  12. Control Strategies for the DAB Based PV Interface System.

    Science.gov (United States)

    El-Helw, Hadi M; Al-Hasheem, Mohamed; Marei, Mostafa I

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system.

  13. Control Strategies for the DAB Based PV Interface System

    Science.gov (United States)

    El-Helw, Hadi M.; Al-Hasheem, Mohamed; Marei, Mostafa I.

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system. PMID:27560138

  14. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  15. PVMirrors: Hybrid PV/CSP collectors that enable lower LCOEs

    Science.gov (United States)

    Fisher, Kate; Yu, Zhengshan Jason; Striling, Rob; Holman, Zachary

    2017-06-01

    The primary challenge with concentrating solar power (CSP) is that the conversion efficiency is low—and the cost high—compared to that of photovoltaics (PV), and the primary challenge with PV is that the energy generated cannot be stored cost effectively. We introduce a technology that hybridizes CSP and PV, resulting in power plants with high energy conversion efficiency and affordable storage. This is accomplished by replacing silvered troughs (or heliostat facets) with "PVMirrors" that and direct photons of each wavelength to the converter (PV or thermal) that may best use them. A PVMirror looks like a curved PV module that includes a spectrum-splitting dichroic mirror film; this film, which is the heart of the technology, transmits near-infrared light to the underlying silicon PV cells while reflecting both longer and shorter wavelengths to a thermal absorber tube. This paper investigates the optical performance of dichroic mirror film, the specularity of PVMirrors, and the anticipated levelized cost of energy (LCOE) from a PVMirror power plant. PVMirrors are found to decrease LCOE by more than 15% relative to CSP while retaining full dispatchability.

  16. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    OpenAIRE

    Tamer Khatib; Azah Mohamed; K. Sopian

    2012-01-01

    This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV) systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN), optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based mo...

  17. Investigation of the Effect Temperature on Photovoltaic (PV) Panel Output Performance

    OpenAIRE

    Amelia Razak; Y.M. Irwan; W.Z. Leow; M Irwanto; I. Safwati; M. Zhafarina

    2016-01-01

    The main limit of PV systems is the low conversion efficiency of PV panels, which is strongly influenced by their operating temperature. Lack of accuracy in consideration through PV panel temperature increases the financial risk of system installation. This present study investigates the effects of operating temperature on monocrystalline PV panel at Perlis, Malaysia. A selected model of PV panel firstly was simulated using PVSYST software in order to evaluate its output performance. Meanwhil...

  18. In Vitro Antifungal Activity of Burkholderia gladioli pv. agaricicola against Some Phytopathogenic Fungi

    Directory of Open Access Journals (Sweden)

    Hazem S. Elshafie

    2012-12-01

    Full Text Available The trend to search novel microbial natural biocides has recently been increasing in order to avoid the environmental pollution from use of synthetic pesticides. Among these novel natural biocides are the bioactive secondary metabolites of Burkholderia gladioli pv. agaricicola (Bga. The aim of this study is to determine antifungal activity of Bga strains against some phytopathogenic fungi. The fungicidal tests were carried out using cultures and cell-free culture filtrates against Botrytis cinerea, Aspergillus flavus, Aspergillus niger, Penicillium digitatum, Penicillium expansum, Sclerotinia sclerotiorum and Phytophthora cactorum. Results demonstrated that all tested strains exert antifungal activity against all studied fungi by producing diffusible metabolites which are correlated with their ability to produce extracellular hydrolytic enzymes. All strains significantly reduced the growth of studied fungi and the bacterial cells were more bioactive than bacterial filtrates. All tested Bulkholderia strains produced volatile organic compounds (VOCs, which inhibited the fungal growth and reduced the growth rate of Fusarium oxysporum and Rhizoctonia solani. GC/MS analysis of VOCs emitted by strain Bga 11096 indicated the presence of a compound that was identified as 1-methyl-4-(1-methylethenyl-cyclohexene, a liquid hydrocarbon classified as cyclic terpene. This compound could be responsible for the antifungal activity, which is also in agreement with the work of other authors.

  19. Role of DetR in defence is critical for virulence of Xanthomonas oryzae pv. oryzae.

    Science.gov (United States)

    Nguyen, Minh-Phuong; Park, Jongchan; Cho, Man-Ho; Lee, Sang-Won

    2016-05-01

    Like other bacteria, Xanthomonas oryzae pv. oryzae (Xoo), the causal agent of bacterial leaf blight disease in rice, possesses intracellular signalling systems, known as two-component regulatory systems (TCSs), which regulate pathogenesis and biological processes. Completion of the genome sequences of three Xoo strains has facilitated the functional study of genes, including those of TCSs, but the biological functions of most Xoo TCSs have not yet been uncovered. To identify TCSs involved in Xoo pathogenesis, we generated knockout strains lacking response regulators (RRs, a cytoplasmic signalling component of the TCS) and examined the virulence of the RR knockout strains. This study presents a knockout strain (detR(-) ) lacking the PXO_04659 gene which shows dramatically reduced virulence relative to the wild-type. Our studies to elucidate detR function in Xoo pathogenesis revealed a reduction in extracellular polysaccharide (EPS), intolerance to reactive oxygen species (ROS) and deregulation of iron homeostasis in the detR(-) strain. Moreover, gene expression of regulatory factors, including other RRs and transcription factors (TFs), was altered in the absence of DetR protein, as determined by reverse transcription-polymerase chain reaction (RT-PCR) and/or real-time quantitative RT-PCR analyses. All evidence leads to the conclusion that DetR is essential for Xoo virulence through the regulation of the Xoo defence system including EPS synthesis, ROS detoxification and iron homeostasis, solely or cooperatively with other regulatory factors.

  20. Genome sequencing reveals a new lineage associated with lablab bean and genetic exchange between Xanthomonas axonopodis pv. phaseoli and Xanthomonas fuscans subsp. fuscans

    Directory of Open Access Journals (Sweden)

    Valente eAritua

    2015-10-01

    Full Text Available Common bacterial blight is a devastating seed-borne disease of common beans that also occurs on other legume species including lablab and Lima beans. We sequenced and analysed the genomes of 26 isolates of Xanthomonas axonopodis pv. phaseoli and X. fuscans subsp. fuscans, the causative agents of this disease, collected over four decades and six continents. This revealed considerable genetic variation within both taxa, encompassing both single-nucleotide variants and differences in gene content, that could be exploited for tracking pathogen spread. The bacterial isolate from Lima bean fell within the previously described Genetic Lineage 1, along with the pathovar type isolate (NCPPB 3035. The isolates from lablab represent a new, previously unknown genetic lineage closely related to strains of X. axonopodis pv. glycines. Finally, we identified more than 100 genes that appear to have been recently acquired by Xanthomonas axonopodis pv. phaseoli from X. fuscans subsp. fuscans.

  1. Large scale PV plants - also in Denmark. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Ahm, P. (PA Energy, Malling (Denmark)); Vedde, J. (SiCon. Silicon and PV consulting, Birkeroed (Denmark))

    2011-04-15

    Large scale PV (LPV) plants, plants with a capacity of more than 200 kW, has since 2007 constituted an increasing share of the global PV installations. In 2009 large scale PV plants with cumulative power more that 1,3 GWp were connected to the grid. The necessary design data for LPV plants in Denmark are available or can be found, although irradiance data could be improved. There seems to be very few institutional barriers for LPV projects, but as so far no real LPV projects have been processed, these findings have to be regarded as preliminary. The fast growing number of very large scale solar thermal plants for district heating applications supports these findings. It has further been investigated, how to optimize the lay-out of LPV plants. Under the Danish irradiance conditions with several winter months with very low solar height PV installations on flat surfaces will have to balance the requirements of physical space - and cost, and the loss of electricity production due to shadowing effects. The potential for LPV plants in Denmark are found in three main categories: PV installations on flat roof of large commercial buildings, PV installations on other large scale infrastructure such as noise barriers and ground mounted PV installations. The technical potential for all three categories is found to be significant and in the range of 50 - 250 km2. In terms of energy harvest PV plants will under Danish conditions exhibit an overall efficiency of about 10 % in conversion of the energy content of the light compared to about 0,3 % for biomass. The theoretical ground area needed to produce the present annual electricity consumption of Denmark at 33-35 TWh is about 300 km2 The Danish grid codes and the electricity safety regulations mention very little about PV and nothing about LPV plants. It is expected that LPV plants will be treated similarly to big wind turbines. A number of LPV plant scenarios have been investigated in detail based on real commercial offers and

  2. PV-HYBRID and MINI-GRID. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Within the 3rd European Conference at the Centre de Congres in Aix en Provence (France) between 11th and 12th May, 2006, the following lessons were held: (1) Small electric networks: European drivers and projects for the integration of RES and DG into the electricity grids of the future (Manuel Sanchez-Jimenez); (2) PV hybrid system within mini grids - IEA PVPS programme (Meuch Konraf); (3) Renewables for the developing world (Alvaro Ponce Plaza); (4) Rural electicity supply using photovoltaic / - Diesel hybrid systems: Attractive for investors in the renewable energy sector? (Andreas Hahn); (5) Economic analysis of stand-alone and grid-connected photovoltaic systems under current tariff structure of Taiwan (Yaw-Juen Wang); (6) Using wind-PV-diesel hybrid system for electrification of remote village in Western Libya (N.M. Kreama); (7) Venezuela's renewable energy program for small towns and rural areas ''Sembrando Luz'' (Jorge Torres); (8) AeroSmart5, the professional, sysem-compatible small-scale wind energy converter will be tested in field tests (Fabian Jochem); (9) Lifetime, test procedures and recommendations for optimal operating strategies for lead-acid-batteries in renewable energy systems - A survey on results from European projects from the 5th framework programme (Rudi Kaiser); (10) Prototype of a reversible fuel cell system for autonomous power supplies (Tom Smolinska); (11) Interconnection management in microgrids (Michel Vandenbergh); (12) Control strategy for a small-scale stand-alone power system based on renewable energy and hydrogen (Harald Miland); (13) Standard renewable electricity supply for people in rural areas - mini-grids in western provinces of China (Michael Wollny); (14) The Brava island a ''100% renewable energy'' project (Jean-Christian Marcel); (15) Breakthrough to a new era of PV-hybrid systems with the help of standardised components communication? (Michael Mueller); (16) Standardized

  3. Performance of a 34 kWp grid-connected PV system in Indonesia - A comparison of tropical and European PV systems

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    We analysed a monitored grid-connected PV system of 34 kWp in Indonesia to investigate the performance of PV systems in tropical climates. The PV system has been installed in Jayapura, the capital of the Province of Papua, Indonesia, by the beginning of 2012. Due to the aged gensets and frequent lac

  4. The acyl-homoserine lactone-type quorum-sensing system modulates cell motility and virulence of Erwinia chrysanthemi pv. zeae.

    Science.gov (United States)

    Hussain, Mumtaz B B M; Zhang, Hai-Bao; Xu, Jin-Ling; Liu, Qiongguang; Jiang, Zide; Zhang, Lian-Hui

    2008-02-01

    Erwinia chrysanthemi pv. zeae is one of the Erwinia chrysanthemi pathovars that infects on both dicotyledons and monocotyledons. However, little is known about the molecular basis and regulatory mechanisms of its virulence. By using a transposon mutagenesis approach, we cloned the genes coding for an E. chrysanthemi pv. zeae synthase of acyl-homoserine lactone (AHL) quorum-sensing signals (expI(Ecz)) and a cognate response regulator (expR(Ecz)). Chromatography analysis showed that expI(Ecz) encoded production of the AHL signal N-(3-oxo-hexanoyl)-homoserine lactone (OHHL). Null mutation of expI(Ecz) in the E. chrysanthemi pv. zeae strain EC1 abolished AHL production, increased bacterial swimming and swarming motility, disabled formation of multicell aggregates, and attenuated virulence of the pathogen on potato tubers. The mutation also marginally reduced the inhibitory activity of E. chrysanthemi pv. zeae on rice seed germination. The mutant phenotypes were rescued by either exogenous addition of AHL signal or in trans expression of expI(Ecz). These data demonstrate that the AHL-type QS signal plays an essential role in modulation of E. chrysanthemi pv. zeae cell motility and the ability to form multicell aggregates and is involved in regulation of bacterial virulence.

  5. Plug and Play PV Systems for American Homes

    Energy Technology Data Exchange (ETDEWEB)

    Hoepfner, Christian [Fraunhofer USA, Inc., Boston, MA (United States)

    2016-12-22

    The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

  6. PV-BUK: Operating and maintenance costs of photovoltaic installations; PV-BUK - Betriebs- und Unterhaltskosten von PV-Anlagen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Stettler, S.; Toggweiler, P. [Enecolo AG, Moenchaltorf (Switzerland); Ruoss, D.; Schudel, P. [Envision, Lucerne (Switzerland); Kottmann, A.; Steinle, F. [BE Netz AG, Lucerne (Switzerland)

    2008-03-15

    This final report elaborated for the Swiss Federal Office of Energy (SFOE) takes a look at the results of a project carried out to determine the costs for facility management, to estimate future cost development and to propose activities for the further reduction of the operation and maintenance costs of photovoltaic systems. Information on the cost situation was collected by literature study, as well as in interviews and surveys with photovoltaic (PV) experts and the owners of PV installations. The discussion of the results at a workshop with about 20 Swiss PV experts is noted. The results are presented and discussed. These show that operating costs per kWh decrease with the size of the PV system. Figures are quoted. The major part of the costs are quoted as being those for spare parts, especially for the inverter. The authors are of the opinion that, in future, costs for facility management will further decrease, as they are partly linked to capital and insurance costs. Potential for optimisation is said to exist in several areas of facility management such as, for example, in system monitoring and fast reaction in the case of malfunctions.

  7. Lifetime Evaluation of PV Inverters considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    The PV inverter lifetime is affected by the installed sites related to different solar irradiance and ambient temperature profiles. In fact, the installation site also affects the PV panel degradation rate, and thus the long-term power production. Prior-art lifetime analysis in PV inverters has...... not yet investigated the impact of panel degradation. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and installation sites. Evaluations have been carried out on PV systems installed in Denmark and Arizona. The results reveal that the PV panel degradation rate...... has a considerable impact on the PV inverter lifetime, especially in the hot climate (e.g., Arizona), where the panel degrades at a faster rate. In that case, the PV inverter lifetime estimation can be deviated by 54%, if the impact of PV panel degradation is not taken into account....

  8. Policies and opportunities for grid parity of PV in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Lako, P.; Beurskens, L.W.M. [ECN Policy Studies, Petten (Netherlands)

    2012-01-15

    In 2010, ECN Policy Studies has provided information on the development of solar PV in the Netherlands to GlobalData, India. Based on this information request, the present note on policies and opportunities for grid parity of PV has been drafted. Recently, subsidies for solar PV in the Netherlands have shown a pattern of a roller-coaster that is typical for PV financing in a number of EU countries. Stop-and-go policies for solar PV may have multiple causes. It may be difficult to determine the right feed-in tariffs for PV; or governments may be reluctant to provide sufficient funding for a relatively expensive renewable electricity source like PV. This note sheds light on the current state of affairs and policies for PV in the Netherlands, and on several private initiatives aimed at reaching grid parity for PV which is installed by households.

  9. Methods for the Optimal Design of Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    and the efficient processing of this power by the DC/AC inverter. In this paper two new methods are presented for the optimal design of a PV inverter power section, output filter and MPPT control strategy. The influences of the electric grid regulations and standards as well as the PV array operational......The DC/AC inverters are used in grid-connected PV energy production systems as the power processing interface between the PV energy source and the electric grid. The energy injected into the electric grid by the PV installation depends on the amount of power extracted from the PV power source...... characteristics on the design of grid-connected PV inverters have been considered. The proposed methods have been applied for the optimal design of PV inverters installed at various sites in Europe. The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy...

  10. Performance of a PV module augmented by a plane reflector

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, G. E; Hussein, H. M. S; Mohamad, M. A [Dokki, Giza (Egypt)

    2000-07-01

    This paper presents a comparative experimental study on the performance of a PV module augmented by a south facing titled plane reflector and another identical one without reflector. The tilt angles of the two PV modules and reflector overhang are selected to be according to a previous theoretical study by the authors. The reflector tilt angle has been changed once a month so that the reflected beams from the plane reflector cover the total surface area of the PV module all days of every month during the high solar radiation period (i.e. three hours before and after solar noon). The study has been carried out on the two PV modules for a complete year under the actual atmospheric conditions of Cairo, Egypt. The measuring system used in the study comprises a data acquisition system, a computer, an electronic load and weather station. The experimental results indicate that the plane reflector enhances the yearly output energy of the PV module y about 22%. [Spanish] Este articulo presenta un estudio comparativo experimental sobre el rendimiento de un modulo de PV aumentado por un reflector plano inclinado mirando hacia el sur y otro identico sin reflector. Los angulos de inclinacion de los dos modulos y el reflector sobresaliente se seleccionan para que esten de acuerdo con un estudio teorico previo hecho por los autores. El angulo de inclinacion del reflector se cambio una vez al mes de manera que los rayos reflejados por el reflector plano cubrieran el area total de la superficie del modulo de PV todos los dias de cada mes durante el periodo de radiacion alto (o sea tres horas antes y despues del medio dia solar). El estudio ha sido llevado a cabo en dos modulos de PV durante un ano completo bajo condiciones atmosfericas reales de El Cairo, Egipto. El sistema de medicion usado en el estudio comprende un sistema de adquisicion de datos, una computadora, una memoria electronica y una estacion climatologica. Los resultados experimentales indican que el reflector plano

  11. PV Reconfiguration Systems: a Technical and Economic Study

    Directory of Open Access Journals (Sweden)

    Caruso M.

    2017-03-01

    Full Text Available Dynamical electrical array reconfiguration strategies for grid-connected PV systems have been proposed as solution to improve energy production due to the mismatch effect of PV plants during partial shading conditions. Strategies are based on the use of dynamic connections between PV panels given by the employment of switches that allow for each panel the series, parallel or exclusion connections, physically changing the electrical connections between the related PV modules, consequentially modifying the layout of the plant. Usually the cost of the dynamic matrix is not taken into account. This novel work evaluates the economic advantages obtained by the use of reconfiguration strategies in PV systems, by taking into consideration the price of energy due to incentives in different European and non-European countries and correlates it with the employment of two types of reconfigurators, with different internal structures. For each of the incentives proposed by the different Countries, the main strength and weakness points of the possible investment are highlighted and critically analyzed. From this analysis, it can be stated that the adoption of reconfiguration systems, in certain cases, can be a very convenient solution.

  12. Solar cell junction temperature measurement of PV module

    KAUST Repository

    Huang, B.J.

    2011-02-01

    The present study develops a simple non-destructive method to measure the solar cell junction temperature of PV module. The PV module was put in the environmental chamber with precise temperature control to keep the solar PV module as well as the cell junction in thermal equilibrium with the chamber. The open-circuit voltage of PV module Voc is then measured using a short pulse of solar irradiation provided by a solar simulator. Repeating the measurements at different environment temperature (40-80°C) and solar irradiation S (200-1000W/m2), the correlation between the open-circuit voltage Voc, the junction temperature Tj, and solar irradiation S is derived.The fundamental correlation of the PV module is utilized for on-site monitoring of solar cell junction temperature using the measured Voc and S at a short time instant with open circuit. The junction temperature Tj is then determined using the measured S and Voc through the fundamental correlation. The outdoor test results show that the junction temperature measured using the present method, Tjo, is more accurate. The maximum error using the average surface temperature Tave as the junction temperature is 4.8 °C underestimation; while the maximum error using the present method is 1.3 °C underestimation. © 2010 Elsevier Ltd.

  13. Thermal performances of vertical hybrid PV/T air collector

    Science.gov (United States)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  14. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine

    2015-12-05

    © 2015 Elsevier Ltd. Solar air conditioning system directly driven by stand-alone solar PV is studied. The air conditioning system will suffer from loss of power if the solar PV power generation is not high enough. It requires a proper system design to match the power consumption of air conditioning system with a proper PV size. Six solar air conditioners with different sizes of PV panel and air conditioners were built and tested outdoors to experimentally investigate the running probabilities of air conditioning at various solar irradiations. It is shown that the instantaneous operation probability (OPB) and the runtime fraction (RF) of the air conditioner are mainly affected by the design parameter rpL (ratio of maximum PV power to load power). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  15. ESTIMATION OF PV MODULE SURFACE TEMPERATURE USING ARTIFICIAL NEURAL NETWORKS

    Directory of Open Access Journals (Sweden)

    Can Coskun

    2016-12-01

    Full Text Available This study aimed to use the artificial neural network (ANN method to estimate the surface temperature of a photovoltaic (PV panel. Using the experimentally obtained PV data, the accuracy of the ANN model was evaluated. To train the artificial neural network (ANN, outer temperature solar radiation and wind speed values were inputs and surface temperature was an output. The ANN was used to estimate PV panel surface temperature. Using the Levenberg-Marquardt (LM algorithm the feed forward artificial neural network was trained. Two back propagation type ANN algorithms were used and their performance was compared with the estimate from the LM algorithm. To train the artificial neural network, experimental data were used for two thirds with the remaining third used for testing. Additionally scaled conjugate gradient (SCG back propagation and resilient back propagation (RB type ANN algorithms were used for comparison with the LM algorithm. The performances of these three types of artificial neural network were compared and mean error rates of between 0.005962 and 0.012177% were obtained. The best estimate was produced by the LM algorithm. Estimation of PV surface temperature with artificial neural networks provides better results than conventional correlation methods. This study showed that artificial neural networks may be effectively used to estimate PV surface temperature.

  16. Planar holographic spectrum-splitting PV module design

    Science.gov (United States)

    Gordon, Michael; Zhang, Deming; Vorndran, Shelby; Russo, Juan M.; Luscombe, Christine K.; Shaheen, Sean E.; Kostuk, Raymond K.

    2012-10-01

    A design is presented for a planar spectrum-splitting photovoltaic (PV) module using Holographic Optical Elements (HOEs). A repeating array of HOEs diffracts portions of the solar spectrum onto different PV materials arranged in alternating strips. Several combinations of candidate PV materials are explored, and theoretical power conversion efficiency is quantified and compared for each case. The holograms are recorded in dichromated gelatin (DCG) film, an inexpensive material which is easily encapsulated directly into the panel. If desired, the holograms can focus the light to achieve concentration. The side-by-side split spectrum layout has advantages compared to a stacked tandem cell approach: since the cells are electrically isolated, current matching constraints are eliminated. Combinations of dissimilar types of cells are also possible: including crystalline, thin film, and organic PV cells. Configurations which yield significant efficiency gain using relatively inexpensive PV materials are of particular interest. A method used to optimize HOE design to work with a different candidate cells and different package aspect ratios is developed and presented. (Aspect ratio is width of the cell strips vs. the thickness of the panel) The relationship between aspect ratio and HOE performance properties is demonstrated. These properties include diffraction efficiency, spectral selectivity, tracking alignment sensitivity, and uniformity of cell illumination.

  17. Solar Plus: A Holistic Approach to Distributed Solar PV

    Energy Technology Data Exchange (ETDEWEB)

    OShaughnessy, Eric J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ardani, Kristen B. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cutler, Dylan S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-08

    Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

  18. Solar Plus: A Holistic Approach to Distributed Solar PV

    Energy Technology Data Exchange (ETDEWEB)

    O' Shaughnessy, Eric; Ardani, Kristen; Cutler, Dylan; Margolis, Robert

    2017-05-25

    Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

  19. Durability Quality Research of Concrete Containing Solar PV Cells

    Directory of Open Access Journals (Sweden)

    Chao Sao-Jeng

    2015-01-01

    Full Text Available In this article we demonstrated the study results of durability quality of concrete containing waste solar PV cells. The study used alkali activator to improve the activity of alkali-activated materials in solar PV cells so as to replace Portland cement as binder in concrete. By using sodium hydroxide as an alkali-activator, a high-pH environment is generated to excite the binding characteristics of alkali-activated materials in solar PV cells, and thus develops better durability of the mixes. The conclusions were made on effect of this cement replacement. As a result, we identified the durability for those of 16 concrete specimens predefined and made to consider various possible control factors. The conclusions also depicted that all experiments but the drying shrinkage may be helpful with the suitable use of control factors as far as concerning the recycled solar PV cells for mixing in concrete. In other words, the durability quality of concrete may be partially unacceptable of containing solar PV cells.

  20. The molybdate-binding protein (ModA) of the plant pathogen Xanthomonas axonopodis pv. citri.

    Science.gov (United States)

    Balan, Andrea; Santacruz, Carolina P; Moutran, Alexandre; Ferreira, Rita C C; Medrano, Francisco J; Pérez, Carlos A; Ramos, Carlos H I; Ferreira, Luís C S

    2006-12-01

    The modABC operon of phytopathogen Xanthomonas axonopodis pv. citri (X. citri) encodes a putative ABC transporter involved in the uptake of the molybdate and tungstate anions. Sequence analyses showed high similarity values of ModA orthologs found in X. campestris pv. campestris (X. campestris) and Escherichia coli. The X. citri modA gene was cloned in pET28a and the recombinant protein, expressed in the E. coli BL21 (DE3) strain, purified by immobilized metal affinity chromatography. The purified protein remained soluble and specifically bound molybdate and tungstate with K(d) 0.29+/-0.12 microM and 0.58+/-0.14 microM, respectively. Additionally binding of molybdate drastically enhanced the thermal stability of the recombinant ModA as compared to the apoprotein. This is the first characterization of a ModA ortholog expressed by a phytopathogen and represents an important tool for functional, biochemical and structural analyses of molybdate transport in Xanthomonas species.

  1. Lifetime Evaluation of Grid-Connected PV Inverters Considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    Lifetime of PV inverters is affected by the installation sites related to different solar irradiance and ambient temperature profiles (also referred to as mission profiles). In fact, the installation site also affects the degradation rate of the PV panels, and thus long-term energy production...... and reliability. Prior-art lifetime analysis in PV inverters has not yet investigated the impact of PV panel degradations. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and mission profiles. Evaluations have been carried out on PV systems installed in Denmark...

  2. Interline Photovoltaic (I-PV) power system - A novel concept of power flow control and management

    OpenAIRE

    2011-01-01

    This paper presents a new system configuration for a large-scale Photovoltaic (PV) power system with multi-line transmission/distribution networks. A PV power plant is reconfigured in a way that two adjacent power system networks/ feeders can be interconnected. The inverter modules in a PV power plant are configured such that the system is represented as a back to back inverter connected multi-line system, called as Interline-PV (I-PV) system. The proposed I-PV system then can be controlled a...

  3. Photovoltaic Module Simulink Model for a Stand-alone PV System

    Science.gov (United States)

    Qi, Chen; Ming, Zhu

    Photovoltaic(PV) Module is indispensable of a stand-alone PV system. In this paper, a one-diode equivalent circuit-based versatile simulation model in the form of masked block PV module is proposed. By the model, it is allowed to estimate behavior of PV module with respect changes on irradiance intensity, ambient temperature and parameters of the PV module. In addition, the model is capable of function of Maximum Power Point Tracking (MPPT) which can be used in the dynamic simulation of stand-alone PV systems.

  4. Comparative assessment of PV plant performance models considering climate effects

    DEFF Research Database (Denmark)

    Tina, Giuseppe; Ventura, Cristina; Sera, Dezso

    2017-01-01

    The paper investigates the effect of climate conditions on the accuracy of PV system performance models (physical and interpolation methods) which are used within a monitoring system as a reference for the power produced by a PV system to detect inefficient or faulty operating conditions....... The methodological approach is based on comparative tests of the analyzed models applied to two PV plants installed respectively in north of Denmark (Aalborg) and in the south of Italy (Agrigento). The different ambient, operating and installation conditions allow to understand how these factors impact the precision...... and effectiveness of such approaches, among these factors it is worth mentioning the different percentage of diffuse component of the yearly solar radiation on the global one. The experimental results show the effectiveness of the proposed approach. In order to have the possibility to analyze and compare...

  5. Chapter 10.3: Reliability and Durability of PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2017-01-07

    Each year the world invests tens of billions of dollars or euros in PV systems with the expectation that these systems will last approximately 25 years. Although the disciplines of reliability, quality, and service life prediction have been well established for numerous products, a full understanding of these is currently challenging for PV modules because the desired service lifetimes are decades, preventing direct verification of lifetime predictions. A number of excellent reviews can be found in the literature summarizing the types of failures that are commonly observed for PV modules. This chapter discusses key failure/degradation mechanisms selected to highlight how the kinetics of failure rates can and cannot be confidently predicted. For EVA-encapsulated modules, corrosion is observed to follow delamination, which then allows water droplets to directly contact the metallization. Extended test protocols such as Qualification Plus were created to address the known problems while standards groups update standard tests through the consensus process.

  6. DC-PLC Modem design for PV module monitoring

    Directory of Open Access Journals (Sweden)

    Seong-Duc Ma

    2016-01-01

    Full Text Available Nowadays, power line communication (PLC is a very efficient technique in cost aspect because it is communication system using power line without extra communication cables. In case of DC-PLC, it send a communication signal of the high frequency band to the monitoring system through the DC power line and is widely used for DC grid or the distributed generation system using DC source. Especially, the management system which evaluates the performance and efficiency of PV module by measuring PV power through monitoring system based on the DC-PLC has been increased. In this paper, apply the DC-PLC method for low cost PV module monitoring system and constitutes a measuring device and communication modem on a MCU. For the communication performance, we use the digital filter and apply the multi-carrier communication. The proposed DC-PLC Modem is verified through simulation and experiment.

  7. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Weng, Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefit the industry at-large.

  8. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Weng, Dean [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefi t the industry at-large.

  9. Z - Source Multi Level Inverter Based PV Generation System

    Directory of Open Access Journals (Sweden)

    T. Lakhmi kanth

    2014-09-01

    Full Text Available In this paper a novel technique of Z-Source multilevel Inverter based PV Generation system is implemented and simulated using MATLAB-Simulink simulation software. The Photovoltaic cells are healthier option for converting solar energy into electricity. Due to high capital cost and low efficiency PV cells have not yet been a fully smart choice for electricity users. To enhance the performance of the system, Z-Source multi level inverter can be used in place of conventional Voltage Source Inverter (VSI in Solar Power Generation System. The PV cell model is developed using circuit mathematical equations. The Z-Source multilevel inverter is modeled to realize boosted DC to AC conversion (inversion with low THD. Outcome shows that the energy conversion efficiency of ZSMLI is a lot improved as compared to conventional voltage Source Inverter (VSI. By doing FFT analysis we can know the total THD.

  10. PV Systems Installed in Marine Vessels: Technologies and Specifications

    Directory of Open Access Journals (Sweden)

    Ioannis Kobougias

    2013-01-01

    Full Text Available Considerations are held about the specificationin whichthe PV plants have to fulfill so that they can be installed on marine vessels. Initially, a brief description of the typical electrical grid of ships is presented, distinguishing the main parts, reporting the typical electrical magnitudes, and choosing the most preferable installation areas. The technical specifications,in whichthe PV plants have to be compatible with, are fully described. They are determined by the special marine environmental conditions, taking into consideration parameters like wind, humidity, shading, corrosion, and limited installation area. The work is carried out with the presentation of the most popular trends in the field of solar cell types and PV system technologies and their ability to keep up with the aforementioned specifications.

  11. Sizing aspects of a small scale grid connected PV system

    Energy Technology Data Exchange (ETDEWEB)

    Bartha, S.; Teodoreanu, D.I.; Teodoreanu, M.; Negreanu, C. [I.C.P.E.-New Energy Sources Laboratory (NESL), Bucharest (Romania); Farkas, I.; Seres, I. [Szent Istvan University, Goedoelloe (Hungary). Department of Physics and Process Control

    2008-07-01

    Photovoltaics can be used in grid connected mode in two ways: as array installed at the end use site, such as on rooftops, or as utility-scale generating stations. The present paper describes a small-scale grid connected Photovoltaic system. The paper starts with the structure and characterization of the system. The principal technical parameter data are also presented. The used monitoring parameters indicate the principal meteorological data, air temperature and solar radiation data for the location sited at Agigea, at the Black Sea and the produced energy by the PV modules. The present application is made by 1 subsystem with 1200 Wp power and with the panel inclination possibility, using different type of PV modules. The paper presents a simulation model for this system realized with commercial software packages and with a one self made Matlab model that evaluates the energy balance of the PV system. All the simulation and measurements data are presented. (orig.)

  12. Comparative analysis of old, recycled and new PV modules

    Directory of Open Access Journals (Sweden)

    Haroon Ashfaq

    2017-01-01

    Full Text Available This paper presents comparative analysis of old, recycled and new PV modules. It is possible to recycle even very old products by modern standard processes in a value-conserving manner. About 90% of the materials recovered from solar panels can be recycled into useful products. Carbon emission and energy cost are low in manufacturing recycled SPV. Modules can be manufactured with recycled materials and reinstalled in systems as a full quality product with today’s technology good for another 25–30 years. Analysis of all the models of PV module is done with the help of MATLAB. This helps in comparison and proves the effectiveness of the recycled PV module based systems.

  13. Lessons Learned from the Photovoltaic Manufacturing Technology/PV Manufacturing R&D and Thin Film PV Partnership Projects

    Energy Technology Data Exchange (ETDEWEB)

    Margolis, R.; Mitchell, R.; Zweibel, K.

    2006-09-01

    As the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program initiates new cost-shared solar energy R&D under the Solar America Initiative (SAI), it is useful to analyze the experience gained from cost-shared R&D projects that have been funded through the program to date. This report summarizes lessons learned from two DOE-sponsored photovoltaic (PV) projects: the Photovoltaic Manufacturing Technology/PV Manufacturing R&D (PVMaT/PVMR&D) project and the Thin-Film PV Partnership project. During the past 10-15 years, these two projects have invested roughly $330 million of government resources in cost-shared R&D and leveraged another $190 million in private-sector PV R&D investments. Following a description of key findings and brief descriptions of the PVMaT/PVMR&D and Thin-Film PV Partnership projects, this report presents lessons learned from the projects.

  14. Design, Fabrication and Certification of Advanced Modular PV Power Systems

    Science.gov (United States)

    Minyard, Glen E.; Lambarski, Timothy J.

    1997-02-01

    The Design, Fabrication and Certification of Advanced Modular PV Power Systems contract is a Photovoltaic Manufacturing Technology (PVMaT) cost-shared contract under Phase 4A1 for Product Driven Systems and Component Technologies. Phase 4A1 has the goals to improve the cost-effectiveness and manufacturing efficiency of PV end-products, optimize manufacturing and packaging methods, and generally improve balance-of-system performance, integration and manufacturing. This contract has the specific goal to reduce the installed PV system life cycle costs to the customer with the ultimate goal of increasing PV system marketability and customer acceptance. The specific objectives of the project are to develop certified, standardized, modular, pre-engineered products lines of our main stand-alone systems, the Modular Autonomous PV Power Supply (MAPPS) and PV-Generator Hybrid System (Photogenset). To date, we have designed a 200 W MAPPS and a 1 kW Photogenset and are in the process of having the MAPPS certified by Underwriters Laboratories (UL Listed) and approved for hazardous locations by Factory Mutual (FM). We have also developed a manufacturing plan for product line expansion for the MAPPS. The Photogenset will be fabricated in February 1997 and will also be UL Listed. Functionality testing will be performed at NREL and Sandia with the intentions of providing verification of performance and reliability and of developing test-based performance specifications. In addition to an expansion on the goals, objectives and status of the project, specific accomplishments and benefits are also presented in this paper.

  15. Time series power flow analysis for distribution connected PV generation.

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J.; Smith, Jeff; Dugan, Roger

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating

  16. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  17. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  18. PV domestic field trial. Third annual technical report

    Energy Technology Data Exchange (ETDEWEB)

    Crick, F.; Davies, N.; Munzinger, M.; Pearsall, N.; Martin, C.

    2004-07-01

    This report summaries the results of a field trials investigating the design, construction and operation of photovoltaic (PV) systems installed during 2003 to provide information for utilities, building developers and those involved in PV installations and operations. Topics examined include the appearance of the systems, their architectural integration, the different fixing methods, the cost effectiveness of the systems, problems encountered, and monitoring activities. Key issues discussed include communication and co-ordination between interested bodies, siting and location, and good practice. Details are given of monitoring inspection visits, and performance analysis.

  19. Spatio-temporal analysis of regional PV generation

    DEFF Research Database (Denmark)

    Nuño Martinez, Edgar; Cutululis, Nicolaos Antonio

    2016-01-01

    Photovoltaic (PV) power is growing in importance worldwide and hence needs to be represented in operation and planning of power system. As opposed to traditional generation technologies, it is characterized by exhibiting both a high variability and a significant spatial dependence. This paper...... presents a fundamental analysis of regional solar generation time series, aiming to potentially facilitate large-scale solar integration. It will focus on characterizing the underlying dependence structure at the system level as well as describing both statistical and temporal properties of regional PV...

  20. Design and Implementation of A PV Powered Tri-Cycle

    Directory of Open Access Journals (Sweden)

    Soumya Das

    2016-04-01

    Full Text Available Solar PV technology is one of the first among the various renewable energy technologies that have been adopted and accepted universally in order to meet the basic needs of generation of electricity. The objective of this paper is to propose a tri-cycle that utilises the application of stand-alone photovoltaic (PV system. A preliminary design and construction of a solar tri-cycle has been performed by evaluating and estimating the required panel size, battery capacity and motor power. Calculation in this paper exhibit that the solar power alone will be sufficient to operate a tri-cycle from one place to another.

  1. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject...... the power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching....

  2. Characteristics of Bacterial Strains from Pseudomonas Genera Isolated from Diseased Plum Trees

    Directory of Open Access Journals (Sweden)

    Veljko Gavrilović

    2008-01-01

    Full Text Available Characteristics of Pseudomonas syringae strains isolated from diseased plum trees are presented is this paper. Based on pathogenic, biochemical and physiological characteristics, isolated starins were divided into two groups: First group of strains, isolated from diseased plum branches with symptoms of suden decay, was simillar to Pseudomonas syringae pv. syringae; second group of strains, isolated from necrotic flower buds on plum trees, exhibited characteristics simillar to Pseudomonas syringae pv. morsprunorum. In addition, phytopathogenic fungi belonging to genera Phomopsis, Botryosphaeria and Leucostoma, were also isolated from diseased plum trees. Further study of these pathogens and their role in the epidemiology of suden plum trees decay is in progress.

  3. Task 9. PV deployment in developing countries. Institutional framework and financial instruments for PV deployment in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-09-15

    This report for the International Energy Agency (IEA) made by Task 9 of the Photovoltaic Power Systems (PVPS) programme takes a look at the institutional framework and financial instruments necessary for PV deployment in developing countries. This guide describes the institutional and financial aspects that need to be addressed to ensure that a long term sustainable (and profitable) PV market is established in developing countries. The guide details main fundamental functions that need to be performed such as the agents needed to perform the functions and their differing roles within the framework, the relationships between these agents and the financial instruments available. It is stated that the majority of the aspects recommended in this guide can be adopted to two main PV deployment models: direct sales and rural electrification and development programmes. It is noted that both approaches will have to be tailored and adapted to local conditions.

  4. Pseudomonas syringae pv. actinidiae from recent outbreaks of kiwifruit bacterial canker belong to different clones that originated in China.

    Directory of Open Access Journals (Sweden)

    Margi I Butler

    Full Text Available A recently emerged plant disease, bacterial canker of kiwifruit (Actinidia deliciosa and A. chinensis, is caused by Pseudomonas syringae pv. actinidiae (PSA. The disease was first reported in China and Japan in the 1980s. A severe outbreak of PSA began in Italy in 2008 and has spread to other European countries. PSA was found in both New Zealand and Chile in 2010. To study the evolution of the pathogen and analyse the transmission of PSA between countries, genomes of strains from China and Japan (where the genus Actinidia is endemic, Italy, New Zealand and Chile were sequenced. The genomes of PSA strains are very similar. However, all strains from New Zealand share several single nucleotide polymorphisms (SNPs that distinguish them from all other PSA strains. Similarly, all the PSA strains from the 2008 Italian outbreak form a distinct clonal group and those from Chile form a third group. In addition to the rare SNPs present in the core genomes, there is abundant genetic diversity in a genomic island that is part of the accessory genome. The island from several Chinese strains is almost identical to the island present in the New Zealand strains. The island from a different Chinese strain is identical to the island present in the strains from the recent Italian outbreak. The Chilean strains of PSA carry a third variant of this island. These genomic islands are integrative conjugative elements (ICEs. Sequencing of these ICEs provides evidence of three recent horizontal transmissions of ICE from other strains of Pseudomonas syringae to PSA. The analyses of the core genome SNPs and the ICEs, combined with disease history, all support the hypothesis of an independent Chinese origin for both the Italian and the New Zealand outbreaks and suggest the Chilean strains also originate from China.

  5. Pseudomonas syringae pv. actinidiae (PSA isolates from recent bacterial canker of kiwifruit outbreaks belong to the same genetic lineage.

    Directory of Open Access Journals (Sweden)

    Angelo Mazzaglia

    Full Text Available Intercontinental spread of emerging plant diseases is one of the most serious threats to world agriculture. One emerging disease is bacterial canker of kiwi fruit (Actinidia deliciosa and A. chinensis caused by Pseudomonas syringae pv. actinidiae (PSA. The disease first occurred in China and Japan in the 1980s and in Korea and Italy in the 1990s. A more severe form of the disease broke out in Italy in 2008 and in additional countries in 2010 and 2011 threatening the viability of the global kiwi fruit industry. To start investigating the source and routes of international transmission of PSA, genomes of strains from China (the country of origin of the genus Actinidia, Japan, Korea, Italy and Portugal have been sequenced. Strains from China, Italy, and Portugal have been found to belong to the same clonal lineage with only 6 single nucleotide polymorphisms (SNPs in 3,453,192 bp and one genomic island distinguishing the Chinese strains from the European strains. Not more than two SNPs distinguish each of the Italian and Portuguese strains from each other. The Japanese and Korean strains belong to a separate genetic lineage as previously reported. Analysis of additional European isolates and of New Zealand isolates exploiting genome-derived markers showed that these strains belong to the same lineage as the Italian and Chinese strains. Interestingly, the analyzed New Zealand strains are identical to European strains at the tested SNP loci but test positive for the genomic island present in the sequenced Chinese strains and negative for the genomic island present in the European strains. Results are interpreted in regard to the possible direction of movement of the pathogen between countries and suggest a possible Chinese origin of the European and New Zealand outbreaks.

  6. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael D.; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John H.

    2016-07-01

    Reduced strength of attachment of the encapsulant resulting from outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  7. Comparison of three different methods of perturbing the potential vorticity field in mesoscale forecasts of Mediterranean heavy precipitation events: PV-gradient, PV-adjoint and PV-satellite

    Science.gov (United States)

    Vich, M.; Romero, R.; Richard, E.; Arbogast, P.; Maynard, K.

    2010-09-01

    Heavy precipitation events occur regularly in the western Mediterranean region. These events often have a high impact on the society due to economic and personal losses. The improvement of the mesoscale numerical forecasts of these events can be used to prevent or minimize their impact on the society. In previous studies, two ensemble prediction systems (EPSs) based on perturbing the model initial and boundary conditions were developed and tested for a collection of high-impact MEDEX cyclonic episodes. These EPSs perturb the initial and boundary potential vorticity (PV) field through a PV inversion algorithm. This technique ensures modifications of all the meteorological fields without compromising the mass-wind balance. One EPS introduces the perturbations along the zones of the three-dimensional PV structure presenting the local most intense values and gradients of the field (a semi-objective choice, PV-gradient), while the other perturbs the PV field over the MM5 adjoint model calculated sensitivity zones (an objective method, PV-adjoint). The PV perturbations are set from a PV error climatology (PVEC) that characterizes typical PV errors in the ECMWF forecasts, both in intensity and displacement. This intensity and displacement perturbation of the PV field is chosen randomly, while its location is given by the perturbation zones defined in each ensemble generation method. Encouraged by the good results obtained by these two EPSs that perturb the PV field, a new approach based on a manual perturbation of the PV field has been tested and compared with the previous results. This technique uses the satellite water vapor (WV) observations to guide the correction of initial PV structures. The correction of the PV field intents to improve the match between the PV distribution and the WV image, taking advantage of the relation between dark and bright features of WV images and PV anomalies, under some assumptions. Afterwards, the PV inversion algorithm is applied to run

  8. Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated such that......This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated...... that compared to the nonoptimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  9. Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barbose, Galen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wiser, Ryan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Darghouth, Naim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goodrich, Alan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-11-30

    The installed capacity of global and U.S. photovoltaic (PV) systems has soared in recent years, driven by declining PV prices and government incentives. The U.S. Department of Energy’s (DOE) SunShot Initiative aims to make PV cost competitive without incentives by reducing the cost of PV-generated electricity by about 75% between 2010 and 2020. This summary report—based on research at Lawrence Berkeley National Laboratory (LBNL) and the National Renewable Energy Laboratory (NREL)—examines progress in PV price reductions to help DOE and other PV stakeholders manage the transition to a market-driven PV industry, and to provide clarity surrounding the wide variety of potentially conflicting data available about PV system prices.

  10. Multiplexed lateral flow microarray assay for detection of citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis pv citri

    Energy Technology Data Exchange (ETDEWEB)

    Cary; R. Bruce (Santa Fe, NM); Stubben, Christopher J. (Los Alamos, NM)

    2011-03-22

    The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.

  11. Power Output Improvement of PV Module for Agricultural Use by Using Inexpensive Sunlight Concentrator

    Institute of Scientific and Technical Information of China (English)

    NISHIMURA Ryo

    2010-01-01

    PV modules are used as stand alone power sources for agricultural equipments such as lifting pumps in farms,where the power infrastructure is not yet improved.In order to expand the agricultural use of PV module,the cost of PV generation should be reduced.In this paper,the power output performance of a commercial PV module was improved by using a sunlight concentrator that could be assembled inexpensively and a simple sun-tracking method.

  12. Equipment and procedures for ON-SITE testing of PV plants and BIPV

    OpenAIRE

    2014-01-01

    Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on...

  13. PV-θ view of the zonal mean state of the atmosphere

    Directory of Open Access Journals (Sweden)

    Aarnout J. Van Delden

    2012-08-01

    Full Text Available The relation between zonal mean potential vorticity (PV in potential temperature (θ coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies are identified. One PV-anomaly, the ‘Ex-UTLS PV-anomaly’, coincides approximately with the extratropical tropopause (310–360 K. It is a permanent feature of the zonal mean state. The other PV-anomaly is located higher in the stratosphere. It exhibits a strong seasonal cycle, i.e. in winter, it is strongly positive, while in summer, it is weakly negative. In the Northern Hemisphere winter, the Ex-UTLS PV-anomaly and the stratospheric PV-anomaly are separated by a ‘surf-zone’, which is characterised by a negative PV-anomaly pole-wards of a positive PV-anomaly. Piecewise PV-inversion reveals that (1 the Ex-UTLS PV-anomaly induces the westerly winds in the troposphere and the lower stratosphere, including the subtropical jet, that (2 the positive stratospheric PV-anomaly induces the stratospheric polar night jet and that (3 the negative polar cap stratospheric PV-anomaly in summer reduces the westerly wind speeds in the troposphere and induces easterly winds in the stratosphere. The Ex-UTLS PV-anomaly is manifest mainly as an isentropic density- (or mass- anomaly. Piecewise PV-inversion of these anomalies in isolation should account for this by an appropriate adjustment of the lower boundary condition.

  14. Performance enhancement of PV cells through micro-channel cooling

    Directory of Open Access Journals (Sweden)

    Muzaffar Ali

    2015-11-01

    Full Text Available Efficiency of a PV cell is strongly dependent on its surface temperature. The current study is focused to achieve maximum efficiency of PV cells even in scorching temperatures in hot climates like Pakistan where the cell surface temperatures can even rise up to around 80 ℃. The study includes both the CFD and real time experimental investigations of a solar panel using micro channel cooling. Initially, CFD analysis is performed by developing a 3D model of a Mono-Crystalline cell with micro-channels to analyze cell surface temperature distribution at different irradiance and water flow rates. Afterwards, an experimental setup is developed for performance investigations under the real conditions of an open climate of a Pakistan's city, Taxila. Two 35W panels are manufactured for the experiments; one is based on the standard manufacturing procedure while other cell is developed with 4mm thick aluminum sheet having micro-channels of cross-section of 1mm by 1mm. The whole setup also includes different sensors for the measurement of solar irradiance, cell power, surface temperature and water flow rates. The experimental results show that PV cell surface temperature drop of around 15 ℃ is achieved with power increment of around 14% at maximum applied water flow rate of 3 LPM. Additionally, a good agreement is also found between CFD and experimental results. Therefore, that study clearly shows that a significant performance improvement of PV cells can be achieved through the proposed cell cooling technique.

  15. PV Systems Reliability Final Technical Report: Ground Fault Detection

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.

  16. 5bv.3.21 PV led engine

    DEFF Research Database (Denmark)

    Thorsteinsson, Sune; Poulsen, Peter Behrensdorff; Dam-Hansen, Carsten

    PV-powered lighting systems, light to light systems (L2L), offer outdoor lighting where it is elsewhere cumbersome to enable lighting. Application of these systems at high latitudes, where the difference in day length between summer and winter is large and the solar energy is less requires smart ...

  17. Grid Integration of Large PV Power Systems Using HVDC Link

    Directory of Open Access Journals (Sweden)

    Gamal Sowilam

    2016-09-01

    Full Text Available This paper explores the interconnection of large scale Photo-Voltaic (PV systems to the grid though a High Voltage Direct Current (HVDC link. HVDC link is recently utilized for transmission lines longer than 50 km. It is usually utilized to interconnect two asynchronous grids with the same or different frequencies while avoiding stability disturbances greatly. A suitable Maximum Power Point Tracking (MPPT techniques is employed to control the performance of the integrated PV system. The system of the HVDC link has two 12-pulse converter using thyristor-bridges. The delay and the extinction angles at the rectifier and the inverter units control the flow and the quantity of the transmitted power from the PV system into the grid. Fixed capacitors and filters are used to provide the AC side with the required reactive power and reduce the harmonic contents. For evaluation purposes, different simulation investigations are carried out with a detailed modeling using the MATLAB. These tests corroborate the efficacy of HVDC link for integrating large PV systems to electrical grids.

  18. Silicon Oxynitride Thin Film Barriers for PV Packaging (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    del Cueto, J. A.; Glick, S. H.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2006-10-03

    Dielectric, adhesion-promoting, moisture barriers comprised of silicon oxynitride thin film materials (SiOxNy with various material stoichiometric compositions x,y) were applied to: 1) bare and pre-coated soda-lime silicate glass (coated with transparent conductive oxide SnO2:F and/or aluminum), and polymer substrates (polyethylene terephthalate, PET, or polyethylene napthalate, PEN); plus 2) pre- deposited photovoltaic (PV) cells and mini-modules consisting of amorphous silicon (a-Si) and copper indium gallium diselenide (CIGS) thin-film PV technologies. We used plasma enhanced chemical vapor deposition (PECVD) process with dilute silane, nitrogen, and nitrous oxide/oxygen gas mixtures in a low-power (< or = 10 milliW per cm2) RF discharge at ~ 0.2 Torr pressure, and low substrate temperatures < or = 100(degrees)C, over deposition areas ~ 1000 cm2. Barrier properties of the resulting PV cells and coated-glass packaging structures were studied with subsequent stressing in damp-heat exposure at 85(degrees)C/85% RH. Preliminary results on PV cells and coated glass indicate the palpable benefits of the barriers in mitigating moisture intrusion and degradation of the underlying structures using SiOxNy coatings with thicknesses in the range of 100-200 nm.

  19. Comparison of Predictive Models for PV Module Performance (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, B.

    2008-05-01

    This paper examines three models used to estimate the maximum power (P{sub m}) of PV modules when the irradiance and PV cell temperature are known: (1) the power temperature coefficient model, (2) the PVFORM model, and (3) the bilinear interpolation model. A variation of the power temperature coefficient model is also presented that improved model accuracy. For modeling values of P{sub m}, an 'effective' plane-of-array (POA) irradiance (E{sub e}) and the PV cell temperature (T) are used as model inputs. Using E{sub e} essentially removes the effects of variations in solar spectrum and reflectance losses, and permits the influence of irradiance and temperature on model performance for P{sub m} to be more easily studied. Eq. 1 is used to determine E{sub e} from T and the PV module's measured short-circuit current (I{sub sc}). Zero subscripts denote performance at Standard Reporting Conditions (SRC).

  20. Recent advances in PV systems technology development in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Imamura, M.; Grottke, M.; Weiss, I. [WIP Renewable Energies Division, Munich (Germany)

    1995-11-01

    The objectives of the photovoltaics (PV) systems technology development were to study several aspects of plant design, monitoring, control, operation, and management of different types of photovoltaic plants. Unsolved problems were to be identified and analysed, and guidelines to improve the monitoring system were to be developed. Principal studies are summarized.

  1. Design of fibre reinforced PV concepts for building integrated applications

    NARCIS (Netherlands)

    Reinders, Angelina H.M.E.; de Wit, H.; de Boer, Andries; Ossenbrink Sinke, W.; Helm, P.

    2009-01-01

    Fibre reinforced polymers present an interesting encapsulation medium for PV-modules. Glass fibres can provide increased strength and stiffness to thin polymer layers overcoming the brittleness and limited deformability of glass-panes. Glass fibre reinforced polymers allows for transparency over a

  2. Luminescence imaging strategies for drone-based PV array inspection

    DEFF Research Database (Denmark)

    Benatto, Gisele Alves dos Reis; Riedel, Nicholas; Thorsteinsson, Sune

    2017-01-01

    he goal of this work is to perform outdoor defect detection imaging that will be used in a fast, accurate and automatic drone-based survey system for PV power plants. The imaging development focuses on techniques that do not require electrical contact, permitting automatic drone inspections to be...

  3. Selecting Solar. Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    This analysis leverages available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  4. PV industry growth and module reliability in Thailand

    Science.gov (United States)

    Chenvidhya, Dhirayut; Seapan, Manit; Sangpongsanont, Yaowanee; Chenvidhya, Tanokkorn; Limsakul, Chamnan; Songprakorp, Roongrojana

    2015-09-01

    The PV applications in Thailand are now installed more than 1.2 GWp cumulatively. It is due to the National Renewable Energy Program and its targets. In the latest Alternative Energy Development Plan (AEDP), the PV electricity production target has increased from 2 GWp to 3 GWp. With this rapid growth, customers and manufacturers seek for module standard testing. So far over one thousands of PV modules per annum have been tested since 2012. The normal tests include type approval test according to TIS standard, acceptance test and testing for local standard development. For type test, the most module failure was found during damp heat test. For annual evaluation test, the power degradation and delamination of power was found between 0 to 6 percent from its nameplate after deployment of 0 to 5 years in the field. For thin-film module, the degradation and delamination was found in range of 0 to 13 percent (about 5 percent on average) from its nameplate for the modules in operation with less than 5 years. However, for the PV modules at the reference site on campus operated for 12 years, the power degradation was ranging from 10 to 15 percent. Therefore, a long term performance assessment needs to be considered to ensure the system reliability.

  5. Development of white LED based PV lighting systems

    Energy Technology Data Exchange (ETDEWEB)

    Sastry, O.S.; Pant, P.C.; Prasad, G.; Kumar, Rajesh; Bandyopadhyay, Bibek [Solar Energy Centre, Ministry of New and Renewable Energy, Block 14, CGO Complex, Lodhi Road, New Delhi 110003 (India); Kamala Devi, V. [Agency for Non-Conventional Energy and Rural Technology, P.B. No. 1094, Pattom, P.O. Kasavadasapuram, Trivandrum, Kerala 695 004 (India)

    2010-09-15

    A high performance white light emitting diode (WLED) based PV lighting system has been developed under a joint project of SEC and ANERT. The system has been analyzed using the test set-ups developed as a part of advanced lighting laboratory (ALL). The results show that the performance is one of the best among the systems developed in the capacity range. (author)

  6. Design of fibre reinforced PV concepts for building integrated applications

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Wit, de H.; Boer, de A.

    2009-01-01

    Fibre reinforced polymers present an interesting encapsulation medium for PV-modules. Glass fibres can provide increased strength and stiffness to thin polymer layers overcoming the brittleness and limited deformability of glass-panes. Glass fibre reinforced polymers allows for transparency over a b

  7. Best practices for mitigating soiling risk on PV power plants

    KAUST Repository

    AlDowsari, A.

    2015-09-24

    Solar power generates proven, predictable and economical energy and new innovations have made solar PV power plants easy to deploy, integrate and maintain. Areas with large solar energy potential are among the dustiest in the world. At first glance, solar would be a natural fit in many of these environments but humidity, airborne dust, and wind of these regions often bring high soiling rates that can accumulate to reduce performance by up to 10% per month on average, where soiling can be a major loss factor that affects the energy yield for PV plants especially in humid and dusty climates. Therefore, to achieve the desired performance ratio and obtain stable generation, mitigation solutions are proposed to overcome dust issues that affect the performance of PV plants. This makes PV module cleaning a key component for long-term plant performance and sustainable profitability. In this paper, a review of the mechanisms and mitigation solutions to overcome soiling on solar installations using real-world testing and verification is investigated with emphasis on dry type cleaning methods. © 2014 IEEE.

  8. ECO-TOURISM SUSTAINABILITY THROUGH PV TECHNOLOGY: A COMPREHENSIVE REVIEW

    Directory of Open Access Journals (Sweden)

    ARAVIND C. V

    2013-12-01

    Full Text Available Through the Economic Transformation program the Malaysian Government aims to consider tourism as one of the major contributors to the country’s economy and as an industry that imbibe on the principles of environmental responsibility and sustainable development. The growing challenges in the prevention of expansion in agriculture, forestry and aquaculture, and over-exploitation of the natural resources, have made ecotourism extremely popular as a solution for developing tourism sites. Ecotourism attracts many people who wish not only to explore natural wonders but also to protect them for future generations. Most of the ecotourism sites are presumably situated far from the conventional energy resources and thus transporting electricity to those areas are discussed as inefficient and unsustainable. However, solar Photo-voltaic (PV system is clean and alternative energy to suffice the energy demands of eco-tourist sites. This paper puts statements of the energy demand in global and its impact on the traditional fossil fuels and proposes PV as an alternative renewable technology pertaining to the eco-tourism application. The paper especially focuses on solar PV systems which not only could supply the energy demand of tourist sites but can also maintain the image of the ecotourism. A case of a model lodge is used for the study, through the energy demand analysis. A comprehensive review on the PV architecture is presented that derive interest in the implementation of such structure for the case presented.

  9. Molecular characterization of Pseudomonas syringae pv. tomato isolates from Tanzania

    DEFF Research Database (Denmark)

    Shenge, K.C.; Stephan, D.; Mabagala, R. B.

    2008-01-01

    pathogenicity assays on tomato, carbon source utilization by the Biolog Microplate system, polymerase chain reaction and restriction fragment length polymorphism (RFLP) analysis. All the P. syringae pv. tomato isolates produced bacterial speck symptoms on susceptible tomato (cv. ‘Tanya') seedlings. Metabolic...

  10. Dye solar cells ( and PV's) in South Africa

    CSIR Research Space (South Africa)

    Le Roux, Lukas J

    2006-02-01

    Full Text Available of the research on PV's in South Africa such as CuInSe(sub2) but with the emphasis on the DSC. The author shall report on the available facilities in South Africa well as the DSC research at the CSIR, which will include specific topics and problems. More...

  11. Rooftop PV system. PV:BONUS Phase 3B, final technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Under the PV:BONUS Program, ECD and United Solar developed, demonstrated and commercialized two new lightweight, flexible BIPV modules specifically designed as replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and can be used to address the even larger roofing-replacement market. An important design feature of these modules, which minimizes the installation and balance-of-system costs, is their ability to be installed by conventional roofing contractors without special training. The modules are fabricated from high-efficiency, triple-junction spectrum-splitting a-Si alloy solar cells developed by ECD and United Solar. These cells are produced on thin, flexible stainless steel substrates and encapsulated with polymer materials. The Phase 3 program began in August 1995. The principal tasks and goals of this program, which have all been successfully completed by ECD and United Solar, are described in the body and appendices of this report.

  12. Insights into xanthomonas axonopodis pv. Citri biofilm through proteomics

    KAUST Repository

    Zimaro, Tamara

    2013-08-07

    Background: Xanthomonas axonopodis pv. Citri (X. a. pv. Citri) causes citrus canker that can result in defoliation and premature fruit drop with significant production losses worldwide. Biofilm formation is an important process in bacterial pathogens and several lines of evidence suggest that in X. a. pv. Citri this process is a requirement to achieve maximal virulence since it has a major role in host interactions. In this study, proteomics was used to gain further insights into the functions of biofilms. Results: In order to identify differentially expressed proteins, a comparative proteomic study using 2D difference gel electrophoresis was carried out on X. a. pv. Citri mature biofilm and planktonic cells. The biofilm proteome showed major variations in the composition of outer membrane proteins and receptor or transport proteins. Among them, several porins and TonB-dependent receptor were differentially regulated in the biofilm compared to the planktonic cells, indicating that these proteins may serve in maintaining specific membrane-associated functions including signaling and cellular homeostasis. In biofilms, UDP-glucose dehydrogenase with a major role in exopolysaccharide production and the non-fimbrial adhesin YapH involved in adherence were over-expressed, while a polynucleotide phosphorylase that was demonstrated to negatively control biofilm formation in E. coli was down-regulated. In addition, several proteins involved in protein synthesis, folding and stabilization were up-regulated in biofilms. Interestingly, some proteins related to energy production, such as ATP-synthase were down-regulated in biofilms. Moreover, a number of enzymes of the tricarboxylic acid cycle were differentially expressed. In addition, X. a. pv. Citri biofilms also showed down-regulation of several antioxidant enzymes. The respective gene expression patterns of several identified proteins in both X. a. pv. Citri mature biofilm and planktonic cells were evaluated by

  13. Real Time Photovoltaic Array Simulator for Testing Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sera, Dezso; Valentini, Massimo; Raducu, Alin

    2008-01-01

    In this paper a real time flexible PV array simulator is presented. It is a system that can simulate different PV panel arrays in specific environmental conditions. To evaluate performance of the Maximum Power Point Tracking (MPPT) of grid-connected Photovoltaic (PV) inverters only measurements...

  14. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants: Report Summary

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul L. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Eichman, Joshua D. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-28

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  15. Developing High PV Penetration Cases for Frequency Response Study of U.S. Western Interconnection

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jin; Zhang, Yingchen; Veda, Santosh; Elgindy, Tarek; Liu, Yilu

    2017-05-11

    Recent large penetrations of solar photovoltaic (PV) generation and the inertial characteristics of inverter-based generation technologies have caught the attention of those in the electric power industry in the United States. This paper presents a systematic approach to developing test cases of high penetrations of PV for the Western Interconnection. First, to examine the accuracy of the base case model, the Western Electricity Coordinating Council (WECC) model is validated by using measurement data from synchronized phasor measurement units. Based on the 2022 Light Spring case, we developed four high PV penetration cases for the WECC system that are of interest to the industry: 5% PV+15 % wind, 25% PV+15% wind, 45% PV+15% wind, 65% PV+15% wind). Additionally, a method to project PV is proposed that is based on collected, realistic PV distribution information, including the current and future PV power plant locations and penetrations in the WECC system. Both the utility-scale PV plant and residential rooftop PV are included in this study.

  16. Analytical expression for electrical efficiency of PV/T hybrid air collector

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Swapnil; Sandhu, G.S.; Tiwari, G.N. [Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016 (India)

    2009-05-15

    The overall electrical efficiency of the photovoltaic (PV) module can be increased by reducing the temperature of the PV module by withdrawing the thermal energy associated with the PV module. In this communication an attempt has been made to develop analytical expression for electrical efficiency of PV module with and without flow as a function of climatic and design parameters. The four different configurations of PV modules are considered for the present study which are defined as; case A (Glass to glass PV module with duct), case B (Glass to glass PV module without duct), case C (Glass to tedlar PV module with duct), case D (Glass to tedlar PV module without duct). Further, experiments were carried out for all configurations under composite climate of New Delhi. It is found that the glass to glass PV modules with duct gives higher electrical efficiency as well as the higher outlet air temperature amongst the all four cases. The annual effect on electrical efficiency of glass to glass type PV module with and without duct is also evaluated. The annual average efficiency of glass to glass type PV module with and without duct is 10.41% and 9.75%, respectively. (author)

  17. Methodology for the optimal design of tansformerless grid-connected PV interters

    DEFF Research Database (Denmark)

    Koutroulis, E.; Blaabjerg, Frede

    2012-01-01

    inverter, such that the PV inverter levelised cost of the generated electricity is minimised. The proposed method constitutes a systematic design process, which is capable to explore the impact of the PV inverter configuration on the trade-off between the PV inverter manufacturing cost and the power losses...

  18. A Novel Technique to Obtain the Health of a PV Panel

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar; Imran, Raja Muhammad; Shoro, Ghulam Mustafa

    2014-01-01

    Power efficiency delivered from a PV panel individually or as larger system for example a PV Solar Form is very much dependent upon many factors for example irradiance, temperature, shadowing and the health of individual PV panels/cells. The first two factors are typically beyond the control of d...

  19. Developing High PV Penetration Cases for Frequency Response Study of U.S. Western Interconnection: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jin; Zhang, Yingchen; Veda, Santosh; Elgindy, Tarek; Liu, Yilu

    2017-04-11

    Recent large penetrations of solar photovoltaic (PV) generation and the inertial characteristics of inverter-based generation technologies have caught the attention of those in the electric power industry in the United States. This paper presents a systematic approach to developing test cases of high penetrations of PV for the Western Interconnection. First, to examine the accuracy of the base case model, the Western Electricity Coordinating Council (WECC) model is validated by using measurement data from synchronized phasor measurement units. Based on the 2022 Light Spring case, we developed four high PV penetration cases for the WECC system that are of interest to the industry: 5% PV+15 % wind, 25% PV+15% wind, 45% PV+15% wind, 65% PV+15% wind). Additionally, a method to project PV is proposed that is based on collected, realistic PV distribution information, including the current and future PV power plant locations and penetrations in the WECC system. Both the utility-scale PV plant and residential rooftop PV are included in this study.

  20. PV-θ view of the zonal mean state of the atmosphere

    NARCIS (Netherlands)

    van Delden, A.J.; Hinssen, Y.B.L.

    2012-01-01

    The relation between zonal mean potential vorticity (PV) in potential temperature (u) coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies

  1. Quantifying system-wide financial costs and benefits of PV in South Africa

    CSIR Research Space (South Africa)

    Bischof-Niemz, T

    2015-09-01

    Full Text Available 000 MW from PV) was commissioned and fed energy into the grid. In this study, the electricity-system-wide direct financial costs and benefits in South Africa from the first 1 000 MW of PV that came online in 2014 are quantified. The two effects of PV...

  2. DOE Request for Information (RFI) DE-FOA-0000153 PV Manufacturing Initiative

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-02-01

    This draft report summarizes the results of the U.S. Department of Energy PV Manufacturing Request for Information (RFI), DE-FOA-0000153, that was released in September 2009. The PV Manufacturing Initiative is intended to help facilitate the development of a strong PV manufacturing industry in the United States.

  3. Household photovoltaic market in Xining, Qingha province, China: the role of local PV business

    Energy Technology Data Exchange (ETDEWEB)

    Ling, S.; Boardman, B. [University of Oxford (United Kingdom). Environmental Change Institute; Twidell, J. [University of Reading (United Kingdom). Dept. of Engineering; AMSET Centre, Horninghold (United Kingdom)

    2002-10-01

    This paper assesses the present and future market for household photovoltaic (PV) systems in rural Northwest China, especially from the PV commerce at Xining, Qinghai Province. This unsubsidised free market is now met by the emerging PV industry in China, which includes cell and module manufacturers, and PV system distributors and assemblers. For widespread deployment of such a renewable energy technology, the development of a local free market seems more successful than donor- or 'government subsidy'-driven programmes. Presently, there is a thriving infant PV industry in Northwest China, mostly centred in Xining. Xining-based PV sales companies have extensive networks for selling, marketing and servicing household PV systems for rural farmers and nomads. Small systems are now ordinary items on sale in local shops. Based on interviews and fieldwork observations with seven major PV sales companies in Xining, the household PV market is assessed from the present business operations of these companies. Detail of primary sources is given with the aim of archiving seminal progress in the history of photovoltaic power. The results suggest that although the household PV market will continue to grow, current government and international sponsored PV programmes can create both opportunities and barriers for the infant PV market an industry in China. (author)

  4. Defining Bankability for Each Step of a PV Project Using IECRE

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2016-07-12

    How can a PV customer know whether a PV plant is 'good'? IECRE was created to provide a cost-effective way to identify 'good' PV plants. This presentation describes the motivation, strategy, and status of the IECRE effort as of July, 2016.

  5. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Eichman, Joshua D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-08-17

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  6. Integrated Three-Port DC-DC Converter for Photovoltaic (PV) Battery Stand-alone Systems

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    Several power sources such as PV solar arrays and battery are often used to manage the power flow for a photovoltaic (PV) based stand-alone power system due to the fluctuation nature of solar energy resource, and deliver a continuous power to the users in an appropriate form. Traditionally, three...... for PV and battery stand-alone system....

  7. Method for Load Sharing and Power Management in a Hybrid PV/Battery Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.

    2016-01-01

    This paper presents a decentralized load sharing and power management method for an islanded microgrid composed of PV units, battery units and hybrid PV/battery units. The proposed method performs all the necessary tasks such as load sharing among the units, battery charging and discharging and PV...

  8. Large Scale Solar Power Integration in Distribution Grids: PV Modelling, Voltage Support and Aggregation Studies

    NARCIS (Netherlands)

    Samadi, A.

    2014-01-01

    Long term supporting schemes for photovoltaic (PV) system installation have led to accommodating large numbers of PV systems within load pockets in distribution grids. High penetrations of PV systems can cause new technical challenges, such as voltage rise due to reverse power flow during light load

  9. Experimental comparison of PV-smoothing controllers using distributed generators

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Ellis, Abraham; Denda, Atsushi; Morino, Kimio; Hawkins, John N.; Arellano, Brian; Shinji, Takao; Ogata, Takao; Tadokoro, Masayuki

    2014-02-01

    The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

  10. Models for a stand-alone PV system[Photovoltaic

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Hansen, L.H.; Bindner, H.

    2000-12-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risoe National Laboratory. The work has been supported by the Danish Ministry of Energy, as a part of the activities in the Solar Energy Centre Denmark. The study is carried out at Risoe National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PV system, namely solar cells, battery, controller, inverter and load. The models for PV module and battery are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model (KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program that provides a graphical interface for building models as modular block diagrams. The non-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements. The performance of the best linear Black box model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risoe. (au)

  11. 'Candidatus Phytoplasmas pruni', a novel taxon associated with X-disease of stone fruits, Prunus spp.: multilocus characterization based on 16S rRNA, secY, and ribosomal protein genes

    Science.gov (United States)

    X-disease is one of the most serious diseases known in peach (Prunus persica). Based on RFLP analysis of 16S rRNA gene sequences, peach X-disease phytoplasma strains from eastern and western United States and eastern Canada were classified in 16S rDNA RFLP group 16SrIII, subgroup A. Phylogenetic a...

  12. Technical monitoring of PV systems in Apeldoorn, Netherlands. September 1997 - September 1999; Technische monitoring van PV-systemen te Apeldoorn. Periode september 1997 - september 1999

    Energy Technology Data Exchange (ETDEWEB)

    Van der Borg, N.J.C.M.; Jansen, M.J. [ECN Zon en Wind, Petten (Netherlands)

    2000-01-01

    Under contract from a Dutch energy distribution company (NUON), ECN is carrying out a monitoring program for a number of PV systems that are installed on houses in the urban area 'Het Woudhuis' in Apeldoorn, Netherlands. It concerns four groups of houses with PV systems which differ from each other in type of PV system or the orientation of the roofs. This document is a report of the technical monitoring concerning one group, comprising of 14 PV systems, during the period from 5 September 1997 to 4 September 1999. The average yield of the PV systems, standardized for a climatological average year for the Netherlands, is 706 kWh/kW{sub p}. An expanded monitoring program was carried out for one of the systems, which has led to detailed information about the incoming radiation, the behaviour of the PV panels and the inverter. 4 refs.

  13. PV-Optitag 2 - 1. phase: Development of CO{sub 2} neutral buildings; PV-Optitag 2 - 1. etape: Udvikling af CO{sub 2} neutrale boliger

    Energy Technology Data Exchange (ETDEWEB)

    Vejsig Pedersen, P.

    2008-04-15

    An integrated PV cell-solar heating roof solution called PV Optitag was developed in close cooperation between architects and engineers to make new CO{sub 2} neutral solutions for urban development projects. A CO{sub 2} neutral rooftop apartment with PV cells in a solar-energy roof exploits an air-based PVT PV-cell solution in combination with a heat pump as well as PV cells integrated into windows. The idea behind the apartment is a zero-energy solution in new buildings or an urban development component, and the apartment has been exhibited in Orestaden, see www.soltag.net. The project gained practical experience in fluid-covered PV cells in combination with heat pumps in housing. (author)

  14. Consequences of Reducing the Cost of PV Modules on a PV Wind Diesel Hybrid System with Limited Sizing Components

    Directory of Open Access Journals (Sweden)

    Jones S. Silva

    2012-01-01

    Full Text Available The use of renewable resources for power supply in family homes has passed the stage of utopia to became a reality, with limits set by technical and economic parameters. This paper presents the results of a project originated from the initiative of a middle-class family to achieve energy independence at home. The starting point was the concept of home with “zero energy” in which the total energy available is equal to the energy consumed. The solution devised to meet the energy demand of the residence in question is a PV wind diesel hybrid system connected to the grid, with the possibility of energy storage in batteries and in the form of heating water and the environment of the house. As a restriction, the family requested that the system would represent little impact to the lifestyle and landscape. This paper aims to assess the consequences of reductions in the cost of the PV modules on the optimization space, as conceived by the software Homer. The results show that for this system, a 50% reduction in the cost of PV modules allows all viable solutions including PV modules.

  15. Update of the Dutch PV specific yield for determination of PV contribution to renewable energy production: 25% more energy!

    NARCIS (Netherlands)

    van Sark, Wilfried; Bosselaar, L.; Gerrissen, P.; Esmeijer, K.B.D.; Moraitis, Panagiotis; van den Donker, M.; Emsbroek, G.

    2014-01-01

    Statistics Netherlands (CBS) annually publishes the contribution of renewables to the Dutch electricity supply, by following a national protocol. The amount of electricity generated by photovoltaic (PV) technology is calculated from the average installed capacity in a particular year multiplied by a

  16. Results from measurements on the PV-VENT systems at Lundebjerg[DENMARK

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.

    2001-05-01

    The objective of the PV-VENT project was research, development, and tests in the following areas: 1. Develop and illustrate different ways of architectural integration of solar energy systems with combined PV power production and pre-heating of ventilation air in buildings, 2. Investigate the potential in pre-heating fresh air to the building by cooling the PV-panels with the fresh air and further to determine how much this cooling will increase the electrical performance of the PV-panels, 3. Develop and test air to air heat exchangers with an efficiency of 80% or above, 4. Develop and test fans and ventilation systems with an overall fan power demand of about 35 W, 5. Develop and test a direct coupling of the PV-panels to the fans in order to avoid the losses in an inverter, 6. Develop and test different ventilation systems utilizing the abovementioned features. Three different ways of integrating PV-panels with pre-heating of fresh air to the building have been demonstrated in Lundebjerg: a large PV-gable with amorphous PV-panels, a PV-facade with polycrystalline (c-Si) PV-panels and solar ventilation chimneys with polycrystalline (c-Si) PV-panels. Especially the latter feature, the solar ventilation chimney is a new and interesting concept as it allows for increased PV areas although the orientation of the building is not optimal for utilization of solar energy, as was the case in Lundebjerg. It is believed that the PV-VENT project has added important information and experience to the field of combining PV and ventilation systems. Information and experience that future systems of this type may benefit from. Several of the components from the project are believed to be able to contribute to set the standards for future PV and ventilation systems. Several of the components from the project is today commercial available and are used in ordinary building projects. (BA)

  17. Detecting loss mechanisms of c-Si PV modules in-situ I-V measurement

    Science.gov (United States)

    Guo, Siyu; Schneller, Eric; Walters, Joe; Davis, Kristopher O.; Schoenfeld, Winston V.

    2016-09-01

    PV module reliability is alsways an important issue for PV industry. In an outdoor PV system, PV modules suffer from degradation due to different factors. It is then very important to determine the loss mechanisms of a PV module and making improvement based on this. It is found in this work that due to mismatch effect, using fitting method to extract I-V characteristics might not be well applied on a PV module, especially when it has non-uniform degradation problem. This work proposes a method to accurately quantify the power loss of PV modules due to different degradation mechanisms, including series resistance (Rs) loss, non-uniform shunting loss and number of shunted cells, uniform shunting loss, uniform current loss, non-uniform current (mismatch) loss, recombination current (J01 and J02) losses of a PV module. All required input information are the measured current-voltage (I-V) curves and short circuit current- open circuit voltage (Isc-Voc) of PV module initial state and final state. The method is first applied to a simulated PV module with various degradation problems. Power loss due to each loss mechanism for the simulated PV module is then extracted using the proposed method and a pie chart can be generated. Comparing with the actual power loss on each loss mechanism, the method proposed in this work is proved to be very accurate. The method is then further applied to a degradated PV module istalled in an outdoor PV system. The power loss on series resistance, shunting and current mismatch are effectively identified and the number of shunted cells is accurately calculated. In the real application, this method can be used in both indoor and outdoor characterization, which can be very beneficial for PV degradation analysis of PV modules and systems.

  18. Integrating High Penetrations of PV into Southern California: Year 2 Project Update; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Mather, B.; Neal, R.

    2012-08-01

    Southern California Edison (SCE) is well into a five-year project to install a total of 500 MW of distributed photovoltaic (PV) energy within its utility service territory. Typical installations to date are 1-3 MW peak rooftop PV systems that interconnect to medium-voltage urban distribution circuits or larger (5 MW peak) ground-mounted systems that connect to medium-voltage rural distribution circuits. Some of the PV system interconnections have resulted in distribution circuits that have a significant amount of PV generation compared to customer load, resulting in high-penetration PV integration scenarios. The National Renewable Energy Laboratory (NREL) and SCE have assembled a team of distribution modeling, resource assessment, and PV inverter technology experts in order to investigate a few of the high-penetration PV distribution circuits. Currently, the distribution circuits being studied include an urban circuit with a PV penetration of approximately 46% and a rural circuit with a PV penetration of approximately 60%. In both cases, power flow on the circuit reverses direction, compared to traditional circuit operation, during periods of high PV power production and low circuit loading. Research efforts during year two of the five-year project were focused on modeling the distribution system level impacts of high-penetration PV integrations, the development and installation of distribution circuit data acquisition equipment appropriate for quantifying the impacts of high-penetration PV integrations, and investigating high-penetration PV impact mitigation strategies. This paper outlines these research efforts and discusses the following activities in more detail: the development of a quasi-static time-series test feeder for evaluating high-penetration PV integration modeling tools; the advanced inverter functions being investigated for deployment in the project's field demonstration and a power hardware-in-loop test of a 500-kW PV inverter implementing a

  19. Switchgrass (Panicum virgatum L. polyubiquitin gene (PvUbi1 and PvUbi2 promoters for use in plant transformation

    Directory of Open Access Journals (Sweden)

    LaFayette Peter R

    2011-07-01

    Full Text Available Abstract Background The ubiquitin protein is present in all eukaryotic cells and promoters from ubiquitin genes are good candidates to regulate the constitutive expression of transgenes in plants. Therefore, two switchgrass (Panicum virgatum L. ubiquitin genes (PvUbi1 and PvUbi2 were cloned and characterized. Reporter constructs were produced containing the isolated 5' upstream regulatory regions of the coding sequences (i.e. PvUbi1 and PvUbi2 promoters fused to the uidA coding region (GUS and tested for transient and stable expression in a variety of plant species and tissues. Results PvUbi1 consists of 607 bp containing cis-acting regulatory elements, a 5' untranslated region (UTR containing a 93 bp non-coding exon and a 1291 bp intron, and a 918 bp open reading frame (ORF that encodes four tandem, head -to-tail ubiquitin monomer repeats followed by a 191 bp 3' UTR. PvUbi2 consists of 692 bp containing cis-acting regulatory elements, a 5' UTR containing a 97 bp non-coding exon and a 1072 bp intron, a 1146 bp ORF that encodes five tandem ubiquitin monomer repeats and a 183 bp 3' UTR. PvUbi1 and PvUbi2 were expressed in all examined switchgrass tissues as measured by qRT-PCR. Using biolistic bombardment, PvUbi1 and PvUbi2 promoters showed strong expression in switchgrass and rice callus, equaling or surpassing the expression levels of the CaMV 35S, 2x35S, ZmUbi1, and OsAct1 promoters. GUS staining following stable transformation in rice demonstrated that the PvUbi1 and PvUbi2 promoters drove expression in all examined tissues. When stably transformed into tobacco (Nicotiana tabacum, the PvUbi2+3 and PvUbi2+9 promoter fusion variants showed expression in vascular and reproductive tissues. Conclusions The PvUbi1 and PvUbi2 promoters drive expression in switchgrass, rice and tobacco and are strong constitutive promoter candidates that will be useful in genetic transformation of monocots and dicots.

  20. Experimental Study on the Electric and Thermal Performance of PV/T System%PV/T系统电热性能的实验研究

    Institute of Scientific and Technical Information of China (English)

    鲁丹; 吕建

    2012-01-01

    介绍了PV/T系统组成的原理,针对PV/T系统的电热性能进行了实验研究,并对实验数据进行了处理.计算出了不同参数下该PV/T系统的热效率和电效率,分析了这些参数对系统热效率的影响,以及PV/T模块表面温度对系统电效率的影响.

  1. Residential Solar PV Planning in Santiago, Chile: Incorporating the PM10 Parameter

    Directory of Open Access Journals (Sweden)

    Gustavo Cáceres

    2014-12-01

    Full Text Available This paper addresses an economic study of the installation of photovoltaic (PV solar panels for residential power generation in Santiago, Chile, based on the different parameters of a PV system, such as efficiency. As a performance indicator, the Levelized Cost of Energy (LCOE was used, which indicates the benefit of the facility vs. the current cost of electrical energy. In addition, due to a high level of airborne dusts typically associated with PM10, the effect of the dust deposition on PV panels’ surfaces and the effect on panel performance are examined. Two different scenarios are analyzed: on-grid PV plants and off-grid PV plants.

  2. Effect of Reactive Power Management of PV Inverters on Need for Energy Storage

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Yang, Guangya

    2013-01-01

    Grid connected Photovoltaic (PV) systems are among the increasingly growing electric power generation units worldwide. The majority of new installations are expected to be residential PVs that are connected into distribution systems. However, the PV hosting capacity of low voltage (LV) grids...... is limited due to the voltage rise at the point of connection associated with the PV feed-in current. Reactive power management using PV inverters and using the electrical energy storage systems (EESS) are amongst the main solutions for increasing the PV hosting capacity in LV grids. In this paper, a method...

  3. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  4. Optimal design of NPC and Active-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    Targeting at a cost-effective deployment of grid-connected PhotoVoltaic (PV) systems, this paper presents a new methodology for the optimal design of transformerless PV inverters, which are based on the Neutral Point Clamped (NPC) and the Active-Neutral Point Clamped (ANPC) topologies. The design...... optimization results demonstrate that a different set of optimal values of the PV inverter switching frequency and output filter components are derived for the NPC and ANPC topologies, respectively, as well as for each of the PV inverter installation sites under study. The NPC and ANPC PV inverter structures...

  5. Very Thin Flexible Coupled Inductors for PV Module Integrated GaN Converter

    DEFF Research Database (Denmark)

    Acanski, Milos; Ouyang, Ziwei; Popovic-Gerber, Jelena

    2012-01-01

    proposed with more granular power processing by means of distributed maximum power point tracking (DMPPT). This is achieved by adjoining a MPPT unit to each PV module in the PV array. This paper presents a step further in the distributed power tracking approach, with a concept of very low profile power......As the PV energy penetrates into the urban area, shortcomings of the conventional centralized PV system architectures become more pronounced under the influence of urban environment with shading, soiling and orientation mismatch issues. To overcome these limitations new PV system architectures were...

  6. Very Thin Flexible Coupled Inductors for PV Module Integrated GaN Converter

    DEFF Research Database (Denmark)

    Acanski, Milos; Ouyang, Ziwei; Popovic-Gerber, Jelena;

    2012-01-01

    As the PV energy penetrates into the urban area, shortcomings of the conventional centralized PV system architectures become more pronounced under the influence of urban environment with shading, soiling and orientation mismatch issues. To overcome these limitations new PV system architectures were...... proposed with more granular power processing by means of distributed maximum power point tracking (DMPPT). This is achieved by adjoining a MPPT unit to each PV module in the PV array. This paper presents a step further in the distributed power tracking approach, with a concept of very low profile power...

  7. PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Valentini, Massimo;

    2008-01-01

    This paper concerns the evaluation of performance of grid-connected PV inverters in terms of conversion efficiency, European efficiency, static and dynamic MPP efficiency. Semi-automated tests were performed in the PV laboratory of the Institute of Energy Technology at the Aalborg University...... (Denmark) on a commercial transformerless PV inverter. Thanks to the available experimental test setups, that provide the required high measuring accuracy, and the developed PV simulator, which is required for MPPT performance evaluation, PV Inverters can be pretested before being tested by accredited...

  8. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  9. Solar Photovoltaic Economic Development: Building and Growing a Local PV Industry, August 2011 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2011-08-01

    The U.S. photovoltaic (PV) industry is forecast to grow, and it represents an opportunity for economic development and job creation in communities throughout the United States. This report helps U.S. cities evaluate economic opportunities in the PV industry. It serves as a guide for local economic development offices in evaluating their community?s competitiveness in the solar PV industry, assessing the viability of solar PV development goals, and developing strategies for recruiting and retaining PV companies to their areas.

  10. A Novel Frequency Restoring Strategy of Hydro-PV Hybrid Microgrid

    DEFF Research Database (Denmark)

    Wei, Feng; Kai, Sun; Guan, Yajuan

    2014-01-01

    The conventional PV systems based on the voltage inverters only inject dispatched power to the utility grid when they work at a grid-connected mode in the hydro-PV hybrid microgrid. Due to the droop method employed for load sharing between generators, as well as the enormous inertia of system....... The existence of frequency steady-state error and the slow active power/frequency dynamic response are inevitable. Therefore, a novel frequency restoring strategy for the hydro-PV hybrid microgrid based on the improved hierarchical control of PV systems is proposed in this paper. The output active power of PV...

  11. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    Directory of Open Access Journals (Sweden)

    Tamer Khatib

    2012-01-01

    Full Text Available This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN, optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based model for metrological prediction uses four meteorological variables, namely, sun shine ratio, day number and location coordinates. As for PV system sizing, iterative methods are used for determining the optimal sizing of three types of PV systems, which are standalone PV system, hybrid PV/wind system and hybrid PV/diesel generator system. The loss of load probability (LLP technique is used for optimization in which the energy sources capacities are the variables to be optimized considering very low LLP. As for determining the optimal PV panels tilt angle and inverter size, the Liu and Jordan model for solar energy incident on a tilt surface is used in optimizing the monthly tilt angle, while a model for inverter efficiency curve is used in the optimization of inverter size.

  12. How PV system ownership can impact the market value of residential homes

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jamie L. [Energy Sense Finance, LLC, Punta Gorda, FL (United States)

    2014-01-01

    There are multiple ways for a homeowner to obtain the electricity generating and savings benefits offered by a photovoltaic (PV) system. These include purchasing a PV system through various financing mechanisms, or by leasing the PV system from a third party with multiple options that may include purchase, lease renewal or PV system removal. The different ownership options available to homeowners presents a challenge to appraisal and real estate professionals during a home sale or refinance in terms of how to develop a value that is reflective of the PV systems operational characteristics, local market conditions, and lender and underwriter requirements. This paper presents these many PV system ownership options with a discussion of what considerations an appraiser must make when developing the contributory value of a PV system to a residential property.

  13. Variation suggestive of horizontal gene transfer at a lipopolysaccharide (lps) biosynthetic locus in Xanthomonas oryzae pv. oryzae, the bacterial leaf blight pathogen of rice

    Science.gov (United States)

    Patil, Prabhu B; Sonti, Ramesh V

    2004-01-01

    Background In animal pathogenic bacteria, horizontal gene transfer events (HGT) have been frequently observed in genomic regions that encode functions involved in biosynthesis of the outer membrane located lipopolysaccharide (LPS). As a result, different strains of the same pathogen can have substantially different lps biosynthetic gene clusters. Since LPS is highly antigenic, the variation at lps loci is attributed to be of advantage in evading the host immune system. Although LPS has been suggested as a potentiator of plant defense responses, interstrain variation at lps biosynthetic gene clusters has not been reported for any plant pathogenic bacterium. Results We report here the complete sequence of a 12.2 kb virulence locus of Xanthomonas oryzae pv. oryzae (Xoo) encoding six genes whose products are homologous to functions involved in LPS biosynthesis and transport. All six open reading frames (ORFs) have atypical G+C content and altered codon usage, which are the hallmarks of genomic islands that are acquired by horizontal gene transfer. The lps locus is flanked by highly conserved genes, metB and etfA, respectively encoding cystathionine gamma lyase and electron transport flavoprotein. Interestingly, two different sets of lps genes are present at this locus in the plant pathogens, Xanthomonas campestris pv. campestris (Xcc) and Xanthomonas axonopodis pv. citri (Xac). The genomic island is present in a number of Xoo strains from India and other Asian countries but is not present in two strains, one from India (BXO8) and another from Nepal (Nepal624) as well as the closely related rice pathogen, Xanthomonas oryzae pv. oryzicola (Xoor). TAIL-PCR analysis indicates that sequences related to Xac are present at the lps locus in both BXO8 and Nepal624. The Xoor strain has a hybrid lps gene cluster, with sequences at the metB and etfA ends, being most closely related to sequences from Xac and the tomato pathogen, Pseudomonas syringae pv. tomato respectively

  14. High-Penetration PV Integration Handbook for Distribution Engineers

    Energy Technology Data Exchange (ETDEWEB)

    Seguin, Rich [Electrical Distribution Design, Blacksburg, VA (United States); Woyak, Jeremy [Electrical Distribution Design, Blacksburg, VA (United States); Costyk, David [Electrical Distribution Design, Blacksburg, VA (United States); Hambrick, Josh [Electrical Distribution Design, Blacksburg, VA (United States); Mather, Barry [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-01

    This handbook has been developed as part of a five-year research project which began in 2010. The National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed together to analyze the impacts of high-penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to leverage the experience that SCE and the project team would gain during the significant installation of 500 MW of commercial scale PV systems (1-5 MW typically) starting in 2010 and completing in 2015 within SCE’s service territory through a program approved by the California Public Utility Commission (CPUC).

  15. Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  16. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  17. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    , resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redis-tributed, and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device......Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved either by modifying the modulation schemes or adding extra power switching devices...... devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency....

  18. Scalable Optimization Methods for Distribution Networks with High PV Integration

    Energy Technology Data Exchange (ETDEWEB)

    Guggilam, Swaroop S.; Dall' Anese, Emiliano; Chen, Yu Christine; Dhople, Sairaj V.; Giannakis, Georgios B.

    2016-07-01

    This paper proposes a suite of algorithms to determine the active- and reactive-power setpoints for photovoltaic (PV) inverters in distribution networks. The objective is to optimize the operation of the distribution feeder according to a variety of performance objectives and ensure voltage regulation. In general, these algorithms take a form of the widely studied ac optimal power flow (OPF) problem. For the envisioned application domain, nonlinear power-flow constraints render pertinent OPF problems nonconvex and computationally intensive for large systems. To address these concerns, we formulate a quadratic constrained quadratic program (QCQP) by leveraging a linear approximation of the algebraic power-flow equations. Furthermore, simplification from QCQP to a linearly constrained quadratic program is provided under certain conditions. The merits of the proposed approach are demonstrated with simulation results that utilize realistic PV-generation and load-profile data for illustrative distribution-system test feeders.

  19. Models for a stand-alone PV system

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Hansen, L.H.;

    2001-01-01

    Energy Centre Denmark. The study is carried out at Risø National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PVsystem, namely solar cells, battery, controller, inverter and load. The models for PV module and battery...... that provides a graphical interface for building models as modular block diagrams. Thenon-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements....... The performance of the best linear Blackbox model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risø....

  20. Modeling and Control of DC/DC Boost Converter using K-Factor Control for MPPT of Solar PV System

    DEFF Research Database (Denmark)

    Vangari, Adithya; Haribabu, Divyanagalakshmi; Sakamuri, Jayachandra N.

    2015-01-01

    PV array, which includes the effect of solar insolation and temperature on PV array output, for the application in power system transient simulations, is also presented. The performance of the PV array model is verified with simulations at different atmospheric conditions. A 160W PV module from BP...

  1. Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Sorloaica-Hickman, N.; Davis, K.; Kurtz, S.; Jordan, D.

    2011-02-01

    The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

  2. Pv rural electrification programme at the Bolivian high plateau

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzo, E.; Aguilera, J. [Instituto de Energia Solar, ETSI Telecomunicacion, (Spain)

    1995-12-31

    Since 1988 the Institute of Solar Energy of the Universidad Politecnica de Madrid is carrying out a pv rural electrification programme at the Bolivian high plateau. This programme has been focused in three aspects: the domestic electrification, users participation and transfer technology. At present, there are about 1,500 electrified dwellings distributed in the Bolivian high plateau. We have got deep knowledge about life style and organization of the aymara Indians who are the inhabitants of the working zone. We think that this knowledge can be very useful for a large scale introduction of PV solar energy in this region. Finally, we present a new way to transfer PV technology to developing countries. Thanks to this programme a group of aymara Indians is able to manufacture charge regulators and electronic ballast to use in the PV installations of the programme. [Espanol] Desde 1988 el Instituto de Energia Solar de la Universidad Politecnica de Madrid esta llevando a cabo un programa fotovoltaico de electrificacion rural en la altiplanicie Boliviana. Este programa ha sido enfocado a tres aspectos: la electrificacion domestica, la participacion de los usuarios y la transferencia de la tecnologia. Actualmente, hay alrededor de 1500 conjuntos habitacionales electrificados distribuidos en la altiplanicie Boliviana. Hemos obtenido un profundo conocimiento del estilo de vida y de la organizacion de los indios aymara que son los habitantes de la zona de trabajo. Pensamos que este conocimiento puede ser muy util para una introduccion en gran escala de la energia solar fotovoltaica en esta region. Finalmente, presentamos una nueva forma de transferir la tecnologia fotovoltaica a paises en desarrollo. Gracias a este programa un grupo de indios aymara pueden fabricar reguladores de carga y balastros electronicos para ser usados en instalaciones fotovoltaicas del programa.

  3. High Penetration PV: How High Can We Go?

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-01

    Brochure highlighting NREL's partnership with SolarCity and Hawaiian Electric (HECO) to increase the penetration of solar photovoltaics on the electricity grid. To better understand the potential impact of transient overvoltages due to load rejection, NREL collaborated with SolarCity and HECO to run a series of tests measuring the magnitude and duration of load rejection overvoltage events and demonstrating the ability of advanced PV inverters to mitigate their impacts.

  4. [Identification and cloning of a novel gene involved in EPS biosynthesis of Xanthomonas campestris pv. campestris].

    Science.gov (United States)

    Lu, Guang-Tao; Tang, Ji-Liang; He, Yong-Qiang; Chen, Bao-Shan; Tang, Dong-Jie

    2003-11-01

    Xanthomonas campestris pv. campestris ( Xcc), causative agent of the black rot disease of cruciferous crops worldwide, produces large amount of extracellular polysaccharide( EPS), which has found wide applications in industry. In order to clone genes involved in EPS biosynthesis, Xcc wild-type strain 8004 was mutagenized with transposon Tn5gus A5, and a number of EPS-defective mutants were isolated. The Tn5gusA5 insertion sites in the mutants were analyzed by using thermal asymmetric interlaced PCR(TAIL-PCR), and the corresponding genes were identified by homology blast to the completely sequenced genome of Xcc 8004 strain. A novel gene, waxE, identified from the EPS-defective mutant 151D09, was found to be disrupted by the insertion of Tn5gusA5 in the open reading frame(ORF) with genome coordinates 4478998bp to 4479819bp.This gene showed 52% similarity to the kdtX gene of Serratia marcescens and 50% to the waaE of Klebsiella pneumoniae at amino acid level, with characteristics of glycostransferase 2 family domain. In order to identify the function of waxE gene, waxE gene deletion mutant of Xcc 8004 was constructed by gene replacement strategy in which waxE gene of genome was replaced by kanamycin resistant gene kan. The waxE gene deletion mutant strain, named Xcc 8570, was confirmed by both PCR and southern analysis. The growth rate of the deletion mutant 8570 in rich medium was not affected, but the EPS yield reduced by 35% as compared with the wildtype strain 8004. The deletion mutant could be completmented in trans with plasmid pLATC8976 harboring an intact waxE gene, and the EPS yield of the mutant was restored. The combined data showed that waxE gene involved in EPS biosynthesis in Xcc.

  5. Modeling and Simulation for Hybrid of PV-Wind system

    Directory of Open Access Journals (Sweden)

    Maged N. F. Nashed

    2015-04-01

    Full Text Available The rising consumption rate of fossil fuels causes a significant pollution impact on the atmosphere, unwanted greenhouse gases has drawn worldwide attention towards renewable energy sources. Moreover, in recent year’s generation of electricity using the different types of renewable sources are specifically evaluated in the economical performance of the overall equipment. This paper focuses on the modeling and analysis of a Standalone Photovoltaic (PV- wind energy hybrid generation system under different conditions using MATLAB. The proposed system consists of two renewable sources i.e. wind and solar energy. Modeling of PV array and wind turbine is explained. The wind subsystem is equipped of an induction generator. In photovoltaic system, the variable DC output voltage is controlled using buck-boost converter for the MPPT. These two systems are combined to operate in parallel and the common bus collects the total energy from the wind and PV systems are uses it to the load and with change the load

  6. Pv rural electrification in Kiribati: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Hurry, Suresh [Energy and Atmosphere Programme, SEED/BPPS UNDP, New York (United States)

    1995-12-31

    In collaboration with the Japan International Cooperation Agency (JICA), United Nations Development Programme (UNDP) participated in the implementation of a photovoltaic (PV) rural electrification project in Kiribati. Under this project, assistance was provided to the Kiribati Solar Energy Company (SEC) in order to enable it to provide electricity service as a micro utility in a effective manner. The assistance provided included installation of 55 PV-based solar home systems and one community system. In addition, the assistance focussed on technical training of SEC personnel on PV systems and management training on accounting, billing, spare parts inventory, etcetera. [Espanol] En colaboracion con la Japan International Cooperation Agency (JICA), el Programa de las Naciones Unidas para el Desarrollo (PNUD) participo en la puesta en practica de un proyecto de electrificacion rural fotovoltaico en Kiribati. Dentro de este proyecto, se proporciono ayuda a la Kiribati Solar Energy Company (SEC) para ponerla en condicion de suministrar el servicio electrico, en una forma efectiva, como una micro empresa electrica. La ayuda proporcionada incluyo la instalacion de 55 sistemas domesticos solares fotovoltaicos y un sistema comunitario. Adicionalmente, la ayuda se enfoco al entrenamiento tecnico del personal de SEC en sistemas fotovoltaicos y en el entrenamiento administrativo en contabilidad, facturacion, inventariado de partes de repuesto, etc.

  7. Sizing PV-wind hybrid energy system for lighting

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2012-09-01

    Full Text Available Sizing of wind and photovoltaic generators ensures lower operational costs and therefore, is considered as an important issue. An approach for sizing along with a best management technique for a PV-wind hybrid system with batteries is proposed in this paper, in which the best size for every component of the system could be optimized according to the weather conditions and the load profile. The average hourly values for wind speed and solar radiation for Izmir, Turkey has been used in the design of the systems, along with expected load profile. A hybrid power model is also developed for battery operation according to the power balance between generators and loads used in the software, to anticipate performances for the different systems according to the different weather conditions. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Using proposed procedure, a 1.2 kWp PV-wind hybrid system was designed for Izmir, and simulated and measured results are presented.

  8. Predicatbility of windstorm Klaus; sensitivity to PV perturbations

    Science.gov (United States)

    Arbogast, P.; Maynard, K.

    2010-09-01

    It appears that some short-range weather forecast failures may be attributed to initial conditions errors. In some cases it is possible to anticipate the behavior of the model by comparison between observations and model analyses. In the case of extratropical cyclone development one may qualify the representation of the upper-level precursors described in terms of PV in the initial conditions by comparison with either satellite ozone or water-vapor. A step forward has been made in developing a tool based upon manual modifications of dynamical tropopause (i.e. height of 1.5 PV units) and PV inversion. After five years of experimentations it turns out that the forecasters eventually succeed in improving the forecast of some strong cyclone development. However the present approach is subjective per se. To measure the subjectivity of the procedure a set of 15 experiments has been performed provided by 7 different people (senior forecasters and scientists involved in dynamical meteorology) in order to improve an initial state of the global model ARPEGE leading to a poor forecast of the wind storm Klaus (24 January 2009). This experiment reveals that the manually defined corrections present common features but also a large spread.

  9. A Variable PV Broad Absorption Line and Quasar Outflow Energetics

    CERN Document Server

    Capellupo, Daniel M; Barlow, Tom A

    2014-01-01

    Broad absorption lines (BALs) in quasar spectra identify high velocity outflows that might exist in all quasars and could play a major role in feedback to galaxy evolution. The viability of BAL outflows as a feedback mechanism depends on their kinetic energies, as derived from the outflow velocities, column densities, and distances from the central quasar. We estimate these quantities for the quasar, Q1413+1143 (redshift $z_e = 2.56$), aided by the first detection of PV $\\lambda\\lambda$1118,1128 BAL variability in a quasar. In particular, PV absorption at velocities where the CIV trough does not reach zero intensity implies that the CIV BAL is saturated and the absorber only partially covers the background continuum source (with characteristic size 22.3 (cm^-2). Variability in the PV and saturated CIV BALs strongly disfavors changes in the ionization as the cause of the BAL variability, but supports models with high-column density BAL clouds moving across our lines of sight. The observed variability time of ...

  10. Comparative Study Between Wind and Photovoltaic (PV) Systems

    Science.gov (United States)

    Taha, Wesam

    This paper reviews two renewable energy systems; wind and photovoltaic (PV) systems. The common debate between the two of them is to conclude which one is better, in terms of cost and efficiency. Therefore, comparative study, in terms of cost and efficiency, is attempted. Regarding total cost of both, wind and PV systems, many parameters must be taken into consideration such as availability of energy (either wind or solar), operation and maintenance, availability of costumers, political influence, and the components used in building the system. The main components and parameters that play major role in determining the overall efficiency of wind systems are the wind turbine generator (WTG), gearbox and control technologies such as power, and speed control. On the other hand, in grid-connected PV systems (GCPVS), converter architecture along with maximum power point tracking (MPPT) algorithm and inverter topologies are the issues that affects the efficiency significantly. Cost and efficiency analyses of both systems have been carried out based on the statistics available till today and would be useful in the progress of renewable energy penetration throughout the world.

  11. Overcoming PV grid issues in the urban areas

    Energy Technology Data Exchange (ETDEWEB)

    Ehara, T.

    2009-10-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at grid issues in urban photovoltaic electricity and how to overcome them. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy as a significant and sustainable renewable energy option. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the goal of mainstreaming PV systems in the urban environment. In this report, PV grid interconnection issues and countermeasures based on the latest studies are identified and summarised. Appropriate and understandable information is provided for all possible stakeholders. Possible impacts and benefits of PV grid interconnection are identified, technical measures designed to eliminate negative impacts and enhance possible benefits are presented. The status of research and demonstration projects is introduced and the latest outcomes are summarised. Recommendations and conclusions based on the review process are summarised and presented.

  12. Rooftop PV system. Final technical progress report, Phase II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    Under this four-year PV:BONUS Program, ECD and United Solar are developing and demonstrating two new lightweight flexible building integrated Photovoltaic (BIPV) modules specifically designed as exact replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and address the even larger roofing replacement market. The modules are designed to be installed by roofing contractors without special training which minimizes the installation and balance of system costs. The modules will be fabricated from high-efficiency, multiple-junction a-Si alloy solar cells developed by ECD and United Solar. Under the Phase I Program, which ended in March 1994, we developed two different concept designs for rooftop PV modules: (1) the United Solar overlapping (asphalt shingle replacement) shingle-type modules and (2) the ECD metal roof-type modules. We also developed a plan for fabricating, testing and demonstrating these modules. Candidate demonstration sites for our rooftop PV modules were identified and preliminary engineering designs for these demonstrations were developed; a marketing study plan was also developed. The major objectives of the Phase II Program, which started in June 1994 was (1) to develop, test, and qualify these new rooftop modules; (2) to develop mechanical and electrical engineering specifications for the demonstration projects; and (3) to develop a marketing/commercialization plan.

  13. Temperature Sensitivity of the Hypersensitive Response of Bell Pepper to Xanthomonas axonopodis pv. vesicatoria.

    Science.gov (United States)

    Romero, A M; Kousik, C S; Ritchie, D F

    2002-02-01

    ABSTRACT When bacterial spot-resistant pepper plants carrying resistance gene Bs2 and infiltrated with incompatible strains of Xanthomonas axonopodis pv. vesicatoria carrying a functional avrBs2 gene (races P1 and P3) were incubated at 32 degrees C, they exhibited an electrolyte leakage and bacterial multiplication pattern in planta similar to that obtained with a compatible strain (race P4) carrying a nonfunctional avrBs2 gene. They also developed disease-like symptoms. Pretreatment of incompatible bacteria at 32 degrees C before infiltration caused a delay in electrolyte leakage less pronounced than that caused by exposing plants to 32 degrees C. Also, plants had to be exposed to 32 degrees C for an hour prior to inoculation to increase symptom expression. These data suggest that the Bs2 gene is temperature sensitive. In other experiments, the avrBs1-Bs1 interaction appeared to be the most heat tolerant and thus the least likely to revert to compatible, whereas the avrBs3-Bs3 interaction had an intermediate sensitivity to elevated temperatures.

  14. Genomic plasticity enables phenotypic variation of Pseudomonas syringae pv. tomato DC3000.

    Directory of Open Access Journals (Sweden)

    Zhongmeng Bao

    Full Text Available Whole genome sequencing revealed the presence of a genomic anomaly in the region of 4.7 to 4.9 Mb of the Pseudomonas syringae pv. tomato (Pst DC3000 genome. The average read depth coverage of Pst DC3000 whole genome sequencing results suggested that a 165 kb segment of the chromosome had doubled in copy number. Further analysis confirmed the 165 kb duplication and that the two copies were arranged as a direct tandem repeat. Examination of the corresponding locus in Pst NCPPB1106, the parent strain of Pst DC3000, suggested that the 165 kb duplication most likely formed after the two strains diverged via transposition of an ISPsy5 insertion sequence (IS followed by unequal crossing over between ISPsy5 elements at each end of the duplicated region. Deletion of one copy of the 165 kb region demonstrated that the duplication facilitated enhanced growth in some culture conditions, but did not affect pathogenic growth in host tomato plants. These types of chromosomal structures are predicted to be unstable and we have observed resolution of the 165 kb duplication to single copy and its subsequent re-duplication. These data demonstrate the role of IS elements in recombination events that facilitate genomic reorganization in P. syringae.

  15. Molecular detection of Xanthomonas oryzae pv.oryzae, Xanthomonas oryzae pv. oryzicola, and Burkholderia glumae in infected rice seeds and leaves

    Institute of Scientific and Technical Information of China (English)

    Wen; Lu; Luqi; Pan; Haijun; Zhao; Yulin; Jia; Yanli; Wang; Xiaoping; Yu; Xueyan; Wang

    2014-01-01

    The polymerase chain reaction(PCR) is particularly useful for plant pathogen detection. In the present study, multiplex PCR and SYBR Green real-time PCR were developed to facilitate the simultaneous detection of three important rice pathogens, Xanthomonas oryzae pv.oryzae, X. oryzae pv. oryzicola, and Burkholderia glumae. The unique PCR primer sets were designed from portions of a putative glycosyltransferase gene of X. oryzae pv. oryzae, an Avr Rxo gene of X. oryzae pv. oryzicola, and an internal transcribed spacer(ITS) sequence of B. glumae. Using a multiplex PCR assay, X. oryzae pv. oryzae, X. oryzae pv. oryzicola, and B. glumae were detected in one PCR reaction that contained the newly developed primer set mix. Using SYBR Green real-time PCR assays, X. oryzae pv. oryzae, X. oryzae pv. oryzicola, and B. glumae were detected at 1, 1, and 10 fg μL-1, respectively. These newly designed molecular assays are sensitive and could be reliable tools for pathogen detection and disease forecasting.

  16. Quantification, challenges and outlook of PV integration in the power system: a review by the European PV Technology Platform

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Baccaro, Federica; De Felice, Matteo;

    2015-01-01

    Integration in the power system has become a limiting factor to the further development of photovoltaics. Proper quantification is needed to evaluate both issues and solutions; the share of annual electricity demand is widely used but we found that some of the metrics which are related to power...... rather than energy better reflect the impact on networks. Barriers to wider deployment of PV into power grids can be split between local technical issues (voltage levels, harmonics distortion, reverse power flows and transformer loading) and system-wide issues (intermittency, reduction of system...... networks. Forecasting, storage, and combination with other renewable sources are interdependent solutions to solve the intermittency issue. Finally, we found that PV is also an opportunity to reduce some investment required to upgrade existing power networks. Through integration with micro-grids and hybrid...

  17. Quantification, challenges and outlook of PV integration in the power system: a review by the European PV Technology Platform

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Baccaro, Federica; De Felice, Matteo;

    2015-01-01

    rather than energy better reflect the impact on networks. Barriers to wider deployment of PV into power grids can be split between local technical issues (voltage levels, harmonics distortion, reverse power flows and transformer loading) and system-wide issues (intermittency, reduction of system......Integration in the power system has become a limiting factor to the further development of photovoltaics. Proper quantification is needed to evaluate both issues and solutions; the share of annual electricity demand is widely used but we found that some of the metrics which are related to power...... networks. Forecasting, storage, and combination with other renewable sources are interdependent solutions to solve the intermittency issue. Finally, we found that PV is also an opportunity to reduce some investment required to upgrade existing power networks. Through integration with micro-grids and hybrid...

  18. Investigation of the Effect Temperature on Photovoltaic (PV Panel Output Performance

    Directory of Open Access Journals (Sweden)

    Amelia Razak

    2016-10-01

    Full Text Available The main limit of PV systems is the low conversion efficiency of PV panels, which is strongly influenced by their operating temperature. Lack of accuracy in consideration through PV panel temperature increases the financial risk of system installation. This present study investigates the effects of operating temperature on monocrystalline PV panel at Perlis, Malaysia. A selected model of PV panel firstly was simulated using PVSYST software in order to evaluate its output performance. Meanwhile, PROVA 200 used to measure and record all electrical data for outdoor experimental during the sunniest day. Besides, the thermal distribution was analysed through PV panel temperatures and thermal imaging. Simulation results implied that the output power of PV panel decreases with increasing of its working temperature followed by the efficiency. The experimental results obviously show that the STC parameters do not represent the real operating conditions of PV panel for outdoor conditions. Less output power was produced affected by the atmospheric factors such as solar irradiance and ambient temperature. These both factors strongly affected the PV panel temperature distribution. In short, the elevating of PV panel temperature contributed to the negative impact on output performance of the panel.

  19. A Non-Modeling Exploration of Residential Solar Photovoltaic (PV) Adoption and Non-Adoption

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, Benjamin O. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moezzi, Mithra [Portland State Univ., Portland, OR (United States); Ingle, Aaron [Portland State Univ., Portland, OR (United States); Lutzenhiser, Loren [Portland State Univ., Portland, OR (United States)

    2017-09-01

    Although U.S. deployment of residential rooftop solar photovoltaic (PV) systems has accelerated in recent years, PV is still installed on less than 1 percent of single-family homes. Most research on household PV adoption focuses on scaling initial markets and modeling predicted growth rather than considering more broadly why adoption occurs. Among the studies that have investigated the characteristics of PV adoption, most collected data from adopters, sometimes with additional non-adopter data, and rarely from people who considered but did not adopt PV. Yet the vast majority of Americans are non-adopters, and they are a diverse group - understanding their ways of evaluating PV adoption is important. Similarly, PV is a unique consumer product, which makes it difficult to apply findings from studies of other technologies to PV. In addition, little research addresses the experience of households after they install PV. This report helps fill some of these gaps in the existing literature. The results inform a more detailed understanding of residential PV adoption, while helping ensure that adoption is sufficiently beneficial to adopters and even non-adopters.

  20. Synergistic activation of the pathogenicity-related proline iminopeptidase gene in Xanthomonas campestris pv. campestris by HrpX and a LuxR homolog.

    Science.gov (United States)

    Zhang, Jingxi; Kan, Jinhong; Zhang, Jieqiong; Guo, Ping; Chen, Xiaoying; Fang, Rongxiang; Jia, Yantao

    2012-10-01

    Xanthomonas campestris pv. campestris strain 8004 contains an orphan quorum-sensing (QS) locus, xccR-pip(Xcc), in which the proline iminopeptidase (pip(Xcc)) gene (where "Xcc" indicates that the pip gene is from X. campestris pv. campestris) is positively regulated by the LuxR homologue XccR by binding to the luxXc box of the pip(Xcc) promoter. The disruption of pip(Xcc) significantly attenuated the virulence of X. campestris pv. campestris. An imperfect plant-inducible promoter (PIP) box is located in the upstream region of the pip(Xcc) promoter, which is the putative binding site of the transcriptional activator HrpX. To explore whether the expression of the pip(Xcc) gene is regulated by HrpX, the expression level of a pip(Xcc) promoter-gusA fusion gene was assayed in an hrpX disruption mutant. The results showed that the lack of HrpX dramatically decreased the β-glucuronidase (GUS) activity. Further analyses using an electrophoretic mobility shift assay (EMSA) and chromatin immunoprecipitation (ChIP)-PCR indicated that the imperfect PIP box in X. campestris pv. campestris is specifically bound to HrpX. These data demonstrated that the pip(Xcc) gene belongs to the hrp regulon and that the imperfect PIP box of the pip(Xcc) promoter could be a cis element for the HrpX protein. We further showed in a pulldown assay that XccR can bind HrpX, suggesting that these two regulatory proteins coactivate the virulence factor by binding to the different cis elements of the pip(Xcc) gene and adapt to the host environment during X. campestris pv. campestris infection.

  1. An aquaporin PvTIP4;1 from Pteris vittata may mediate arsenite uptake.

    Science.gov (United States)

    He, Zhenyan; Yan, Huili; Chen, Yanshan; Shen, Hongling; Xu, Wenxiu; Zhang, Haiyan; Shi, Lei; Zhu, Yong-Guan; Ma, Mi

    2016-01-01

    The fern Pteris vittata is an arsenic hyperaccumulator. The genes involved in arsenite (As(III)) transport are not yet clear. Here, we describe the isolation and characterization of a new P. vittata aquaporin gene, PvTIP4;1, which may mediate As(III) uptake. PvTIP4;1 was identified from yeast functional complement cDNA library of P. vittata. Arsenic toxicity and accumulating activities of PvTIP4;1 were analyzed in Saccharomyces cerevisiae and Arabidopsis. Subcellular localization of PvTIP4;1-GFP fusion protein in P. vittata protoplast and callus was conducted. The tissue expression of PvTIP4;1 was investigated by quantitative real-time PCR. Site-directed mutagenesis of the PvTIP4;1 aromatic/arginine (Ar/R) domain was studied. Heterologous expression in yeast demonstrates that PvTIP4;1 was able to facilitate As(III) diffusion. Transgenic Arabidopsis showed that PvTIP4;1 increases arsenic accumulation and induces arsenic sensitivity. Images and FM4-64 staining suggest that PvTIP4;1 localizes to the plasma membrane in P. vittata cells. A tissue location study shows that PvTIP4;1 transcripts are mainly expressed in roots. Site-directed mutation in yeast further proved that the cysteine at the LE1 position of PvTIP4;1 Ar/R domain is a functional site. PvTIP4;1 is a new represented tonoplast intrinsic protein (TIP) aquaporin from P. vittata and the function and location results imply that PvTIP4;1 may be involved in As(III) uptake.

  2. EcPV2 DNA in equine genital squamous cell carcinomas and normal genital mucosa.

    Science.gov (United States)

    Bogaert, Lies; Willemsen, Anouk; Vanderstraeten, Eva; Bracho, Maria A; De Baere, Cindy; Bravo, Ignacio G; Martens, Ann

    2012-07-01

    Squamous cell carcinoma (SCC) represents the most common genital malignant tumor in horses. Similar to humans, papillomaviruses (PVs) have been proposed as etiological agents and recently Equine papillomavirus type 2 (EcPV2) has been identified in a subset of genital SCCs. The goals of this study were (1) to determine the prevalence of EcPV2 DNA in tissue samples from equine genital SCCs, penile intraepithelial neoplasia (PIN) and penile papillomas, using EcPV2-specific PCR, (2) to examine the prevalence of latent EcPV2 infection in healthy genital mucosa and (3) to determine genetic variability within EcPV2 and to disentangle phylogenetic relationships of EcPV2 among PVs. EcPV2 DNA was detected in all but one penile SCC (15/16), in all PIN lesions (8/8) and penile papillomas (4/4). Additionally, EcPV2 DNA was demonstrated in one of two metastasized lymph nodes, one contact metastasis in the mouth, two vaginal and one anal lesion. In healthy horses, EcPV2 DNA was detected in 10% (4/39) of penile swabs but in none of vulvovaginal swabs (0/20). This study confirms the presence of EcPV2 DNA in equine genital SCCs and shows its involvement in anal lesions, a lymph node and contact metastases. Latent EcPV2 presence was also shown in normal male genital mucosa. We found that different EcPV2 variants cocirculate among horses and that EcPV2 is related to the Delta+Zeta PVs and is only a very distant relative of high-risk human PVs causing genital cancer. Thus, similar viral tropism and similar malignant outcome of the infection do not imply close evolutionary relationship.

  3. Brunenders: a partially attenuated historic poliovirus type I vaccine strain.

    Science.gov (United States)

    Sanders, Barbara P; Liu, Ying; Brandjes, Alies; van Hoek, Vladimir; de Los Rios Oakes, Isabel; Lewis, John; Wimmer, Eckard; Custers, Jerome H H V; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana

    2015-09-01

    Brunenders, a type I poliovirus (PV) strain, was developed in 1952 by J. F. Enders and colleagues through serial in vitro passaging of the parental Brunhilde strain, and was reported to display partial neuroattenuation in monkeys. This phenotype of attenuation encouraged two vaccine manufacturers to adopt Brunenders as the type I component for their inactivated poliovirus vaccines (IPVs) in the 1950s, although today no licensed IPV vaccine contains Brunenders. Here we confirmed, in a transgenic mouse model, the report of Enders on the reduced neurovirulence of Brunenders. Although dramatically neuroattenuated relative to WT PV strains, Brunenders remains more virulent than the attenuated oral vaccine strain, Sabin 1. Importantly, the neuroattenuation of Brunenders does not affect in vitro growth kinetics and in vitro antigenicity, which were similar to those of Mahoney, the conventional type I IPV vaccine strain. We showed, by full nucleotide sequencing, that Brunhilde and Brunenders differ at 31 nucleotides, eight of which lead to amino acid changes, all located in the capsid. Upon exchanging the Brunenders capsid sequence with that of the Mahoney capsid, WT neurovirulence was regained in vivo, suggesting a role for the capsid mutations in Brunenders attenuation. To date, as polio eradication draws closer, the switch to using attenuated strains for IPV is actively being pursued. Brunenders preceded this novel strategy as a partially attenuated IPV strain, accompanied by decades of successful use in the field. Providing data on the attenuation of Brunenders may be of value in the further construction of attenuated PV strains to support the grand pursuit of the global eradication of poliomyelitis.

  4. Characterisation of Si-crystalline PV modules by artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Almonacid, F.; Rus, C.; Hontoria, L.; Fuentes, M.; Nofuentes, G. [Grupo Investigacion y Desarrollo en Energia Solar y Automatica, Dpto. de Ingenieria Electronica y Automatica, E.P.S. Jaen, Universidad de Jaen, Despacho B-110-AB, C vertical stroke Alfoso X El Sabio n 28, 23071 Linares (Jaen) (Spain)

    2009-04-15

    In the photovoltaic field, manufacturers provide ratings for PV modules for conditions referred to as standard test conditions (STC). However, these conditions rarely occur outdoors, so the usefulness and applicability of the indoors' characterisation in standard test conditions of PV modules are a controversial issue. Therefore, to carry out photovoltaic engineering well, a suitable characterisation of PV module electrical behaviour (V-I curves) is necessary. The IDEA Research Group from Jaen University has developed a method based on artificial neural networks (ANNs) to electrical characterisation of PV modules. An ANN has been developed which is able to generate V-I curves of Si-crystalline PV modules for any irradiance and module cell temperature. The results show that the proposed ANN introduces a good accurate prediction for Si-crystalline PV modules' performance when compared with the measured values. (author)

  5. Methods and Strategies for Overvoltage Prevention in Low Voltage Distribution Systems with PV

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob

    2016-01-01

    , the overvoltage caused by high PV penetration is described, solutions to facilitate higher PV penetration are classified, and their effectiveness, advantages, and disadvantages are illustrated. The investigated solutions include the grid reinforcement, electrical energy storage application, reactive power......The rapid development of photovoltaic (PV) systems in electrical grids brings new challenges in the control and operation of power systems. A considerable share of already installed PV units are small-scale units, usually connected to low voltage (LV) distribution systems that were not designed...... to handle a high share of PV power. This paper provides an in-depth review of methods and strategies proposed to prevent overvoltage in LV grids with PV, and discusses the effectiveness, advantages, and disadvantages of them in detail. Based on the mathematical framework presented in the paper...

  6. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  7. Determining the maximum feasible amount of photovoltaics in the European transmission grid under optimal PV utilization

    Energy Technology Data Exchange (ETDEWEB)

    Cherevatskiy, Stanislav; Troester, Eckehard [Energynautics GmbH, Langen (Germany)

    2012-07-01

    In the past few years a significant growth of the number of photovoltaic (PV) systems has been observed worldwide and particularly in Europe. Increasing maturity of this technology and growing manufacturing capacities have led to a considerable decline in prices. Looking at a future possible development of installed PV capacities in Europe, the paper at hand investigates how well the available PV energy is made use of when the installed capacity of PV reaches nearly 2000 gigawatt-peak (GWp). A methodology is presented that aims at optimal placement of PV plants taking into consideration region-specific irradiation conditions in Europe and restrictions imposed by the transmission network. Additionally, a mehtod for optimized placement and dimensioning of storage systems along with their best possible operation strategy is applied for assessment of the effect on PV utilization. (orig.)

  8. Statistical overview of findings by IR-inspections of PV-plants

    Science.gov (United States)

    Buerhop, Claudia; Pickel, Tobias; Scheuerpflug, Hans; Camus, Christian; Hauch, Jens; Brabec, Christoph J.

    2016-09-01

    First statistical evaluation of IR-inspections of PV-plants reveals that 86% of the installed PV-plants show IR-abnormalities. More than 120 PV-plants with more than 160,000 PV-modules were inspected and evaluated statistically. Main IR-abnormalities or failures in modules and string installations are analyzed, respectively. The average failure rate for PV-modules is about 8% and for module strings approximately 4%. The differentiation between the installation locations reveals that small residential installation show relatively more defective modules than large field installations. - Therefore, IR-imaging is a valuable method to give fast and reliable information about the actual quality and failure rate in inspected PV-installations.

  9. Optimal Planning Strategy for Large PV/Battery System Based on Long-Term Insolation Forecasting

    Science.gov (United States)

    Yona, Atsushi; Uchida, Kosuke; Senjyu, Tomonobu; Funabashi, Toshihisa

    Photovoltaic (PV) systems are rapidly gaining acceptance as some of the best alternative energy sources. Usually the power output of PV system fluctuates depending on weather conditions. In order to control the fluctuating power output for PV system, it requires control method of energy storage system. This paper proposes an optimization approach to determine the operational planning of power output for PV system with battery energy storage system (BESS). This approach aims to obtain more benefit for electrical power selling and to smooth the fluctuating power output for PV system. The optimization method applies genetic algorithm (GA) considering PV power output forecast error. The forecast error is based on our previous works with the insolation forecasting at one day ahead by using weather reported data, fuzzy theory and neural network(NN). The validity of the proposed method is confirmed by the computer simulations.

  10. Research Status and Solution for Photovoltaic/thermal (PV/T) Solar System%光伏/热(PV/T)太阳能系统的研究现状及解决方案

    Institute of Scientific and Technical Information of China (English)

    何永泰; 肖丽仙; 刘晋豪; 李雷

    2014-01-01

    The research status of the photovoltaic/thermal ( PV/T) solar system is introduced in the paper. The cause of poor practicability for the PV/T solar system is analyzed. In order to improver the practicability of the PV/T solar system, the solutions ( integrated condenser in PV/T solar system, opti-mized the structure of PV/T collector, balance of the conversion efficiency and the operation temperature, perfection evaluation method) are proposed based on the structure and theory of the PV/T collector.%本文介绍了PV/T太阳能系统的研究现状,分析了导致PV/T太阳能系统实用性差的原因。根据PV/T太阳能系统的结构特点及其相关理论,提出聚光技术与PV/T太阳能系统集成、 PV/T集热器结构优化、 PV/T太阳能系统转换效率与工作温度之间的平衡及完善PV/T太阳能特性评价体系的解决方案。实验证明方案有利于提高PV/T太阳能系统的实用性。

  11. Pathotype and genetic diversity amongst Indian isolates of Xanthomonas oryzae pv. oryzae.

    Directory of Open Access Journals (Sweden)

    Deo Mishra

    Full Text Available A number of rice resistance genes, called Xa genes, have been identified that confer resistance against various strains of Xanthomonas oryzae pv. oryzae (Xoo, the causal agent of bacterial blight. An understanding of pathotype diversity within the target pathogen population is required for identifying the Xa genes that are to be deployed for development of resistant rice cultivars. Among 1024 isolates of Xoo collected from 20 different states of India, 11 major pathotypes were distinguished based on their reaction towards ten Xa genes (Xa1, Xa3, Xa4, xa5, Xa7, xa8, Xa10, Xa11, xa13, Xa21. Isolates belonging to pathotype III showing incompatible interaction towards xa8, xa13 and Xa21 and compatible interaction towards the rest of Xa genes formed the most frequent (41% and widely distributed pathotype. The vast majority of the assayed Xoo isolates were incompatible with one or more Xa genes. Exceptionally, the isolates of pathotype XI were virulent on all Xa genes, but have restricted distribution. Considering the individual R-genes, Xa21 appeared as the most broadly effective, conferring resistance against 88 % of the isolates, followed in decreasing order by xa13 (84 %, xa8 (64 %, xa5 (30 %, Xa7 (17 % and Xa4 (14 %. Fifty isolates representing all the eleven pathotypes were analyzed by southern hybridization to determine their genetic relatedness using the IS1112 repeat element of Xoo. Isolates belonging to pathotype XI were the most divergent. The results suggest that one RFLP haplotype that is widely distributed all over India and is represented in strains from five different pathotypes might be an ancestral haplotype. A rice line with xa5, xa13 and Xa21 resistance genes is resistant to all strains, including those belonging to pathotype XI. This three gene combination appears to be the most suitable Xa gene combination to be deployed in Indian rice cultivars.

  12. Incremental Conductance MPPT Algorithm for PV System Implemented Using DC-DC Buck and Boost Converter

    OpenAIRE

    2014-01-01

    The two basic topologies of switch mode DC-DC converters (Buck and Boost) are analyzed with a view of their use in PV (photovoltaic) systems, as the photovoltaic generator exhibits non-linear characteristics due to the change in environmental condition and load variation. As the efficiency of PV panels is low it becomes mandatory to extract maximum power from the PV panel at a given period of time. Several MPPT algorithms with different types of converters are being proposed f...

  13. Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

  14. Grid Integration of PV Power based on PHIL testing using different Interface Algorithms

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2013-01-01

    Photovoltaic (PV) power among all renewable energies had the most accelerated growth rate in terms of installed capacity in recent years. Transmission System Operators (TSOs) changed their perspective about PV power and started to include it into their planning and operation, imposing PV systems...... and supply of ancillary services, first the grid has to be simulated using PHIL, but in order to achieve it, different interface algorithms (IA) had to be evaluated in terms of system stability and signal accuracy....

  15. Final Technical Report: Advanced Measurement and Analysis of PV Derate Factors.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burton, Patrick D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hansen, Clifford [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The Advanced Measurement and Analysis of PV Derate Factors project focuses on improving the accuracy and reducing the uncertainty of PV performance model predictions by addressing a common element of all PV performance models referred to as “derates”. Widespread use of “rules of thumb”, combined with significant uncertainty regarding appropriate values for these factors contribute to uncertainty in projected energy production.

  16. Regulatory islanding parameters in battery based solar PV for electricity system resiliency

    OpenAIRE

    Alsayyed, Nidal; Zhu, Weihang

    2016-01-01

    Distributed battery based solar power photovoltaic (PV) systems have the potential to supply electricity during grid outages resulting from extreme weather or other emergency situations. As such, distributed PV can significantly increase the resiliency of the electricity system. In order to take advantage of this capability, however, the PV systems must be designed with regulatory parameters in mind and combined with other technologies, such as smart energy storage and auxiliary generation. S...

  17. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    Energy Technology Data Exchange (ETDEWEB)

    O' Shaughnessy, Eric; Margolis, Robert

    2017-05-18

    We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

  18. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    Energy Technology Data Exchange (ETDEWEB)

    O' Shaughnessy, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-19

    We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

  19. Field analysis of solar PV-based collective systems for rural electrification.

    OpenAIRE

    Díaz, P.; Peña, R.; Muñoz Cano, Javier; Arias, C. A.; Sandoval, D

    2011-01-01

    This article analyses the long-term performance of collective off-grid photovoltaic (PV) systems in rural areas. The use of collective PV systems for the electrification of small medium-size villages in developing countries has increased in the recent years. They are basically set up as stand-alone installations (diesel hybrid or pure PV) with no connection with other electrical grids. Their particular conditions (isolated) and usual installation places (far from commercial/industrial centers...

  20. Optimal Capacity Allocation of Large-Scale Wind-PV-Battery Units

    OpenAIRE

    Kehe Wu; Huan Zhou; Jizhen Liu

    2014-01-01

    An optimal capacity allocation of large-scale wind-photovoltaic- (PV-) battery units was proposed. First, an output power model was established according to meteorological conditions. Then, a wind-PV-battery unit was connected to the power grid as a power-generation unit with a rated capacity under a fixed coordinated operation strategy. Second, the utilization rate of renewable energy sources and maximum wind-PV complementation was considered and the objective function of full life cycle-net...

  1. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    PVs. In order to increase PV penetration level further, new voltage support control functions for individual inverters are required. This paper investigates distributed reactive power regulation and active power curtailment strategies regarding the development of PV connection capacity by evaluation......Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections from...

  2. Characterization of Novel Bacteriophages for Biocontrol of Bacterial Blight in Leek Caused by Pseudomonas syringae pv. porri.

    Science.gov (United States)

    Rombouts, Sofie; Volckaert, Anneleen; Venneman, Sofie; Declercq, Bart; Vandenheuvel, Dieter; Allonsius, Camille N; Van Malderghem, Cinzia; Jang, Ho B; Briers, Yves; Noben, Jean P; Klumpp, Jochen; Van Vaerenbergh, Johan; Maes, Martine; Lavigne, Rob

    2016-01-01

    Pseudomonas syringae pv. porri, the causative agent of bacterial blight in leek (Allium porrum), is increasingly frequent causing problems in leek cultivation. Because of the current lack of control measures, novel bacteriophages were isolated to control this pathogen using phage therapy. Five novel phages were isolated from infected fields in Flanders (vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3, vB_PsyM_KIL4, and vB_PsyM_KIL5), and were complemented with one selected host range mutant phage (vB_PsyM_KIL3b). Genome analysis of the phages revealed genome sizes between 90 and 94 kb and an average GC-content of 44.8%. Phylogenomic networking classified them into a novel clade, named the "KIL-like viruses," related to the Felixounalikevirus genus, together with phage phiPsa374 from P. syringae pv. actinidiae. In vitro characterization demonstrated the stability and lytic potential of these phages. Host range analysis confirmed heterogeneity within P. syringae pv. porri, leading to the development of a phage cocktail with a range that covers the entire set of 41 strains tested. Specific bio-assays demonstrated the in planta efficacy of phages vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3, and vB_PsyM_KIL3b. In addition, two parallel field trial experiments on three locations using a phage cocktail of the six phages showed variable results. In one trial, symptom development was attenuated. These data suggest some potential for phage therapy in controlling bacterial blight of leek, pending optimization of formulation and application methods.

  3. Characterization of novel bacteriophages for biocontrol of bacterial blight in leek caused by Pseudomonas syringae pv. porri

    Directory of Open Access Journals (Sweden)

    Sofie eRombouts

    2016-03-01

    Full Text Available Pseudomonas syringae pv. porri, the causative agent of bacterial blight in leek (Allium porrum, is increasingly frequent causing problems in leek cultivation. Because of the current lack of control measures, novel bacteriophages were isolated to control this pathogen using phage therapy. Five novel phages were isolated from infected fields in Flanders (vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3, vB_PsyM_KIL4 and vB_PsyM_KIL5, and were complemented with one selected host range mutant phage (vB_PsyM_KIL3b. Genome analysis of the phages revealed genome sizes between 90 and 94 kb and an average GC-content of 44.8%. Phylogenomic networking classified them into a novel clade, named the ‘KIL-like viruses’, related to the Felixounalikevirus genus, together with phage phiPsa374 from Pseudomonas syringae pv. actinidiae. In vitro characterization demonstrated the stability and lytic potential of these phages. Host range analysis confirmed heterogeneity within P. syringae pv. porri, leading to the development of a phage cocktail with a range that covers the entire set of 41 strains tested. Specific bio-assays demonstrated the in planta efficacy of phages vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3 and vB_PsyM_KIL3b. In addition, two parallel field trial experiments on three locations using a phage cocktail of the six phages showed variable results. In one trial, symptom development was attenuated. These data suggest some potential for phage therapy in controlling bacterial blight of leek, pending optimization of formulation and application methods.

  4. Translocation and functional analysis of Pseudomonas savastanoi pv. savastanoi NCPPB 3335 type III secretion system effectors reveals two novel effector families of the Pseudomonas syringae complex.

    Science.gov (United States)

    Matas, Isabel M; Castañeda-Ojeda, M Pilar; Aragón, Isabel M; Antúnez-Lamas, María; Murillo, Jesús; Rodríguez-Palenzuela, Pablo; López-Solanilla, Emilia; Ramos, Cayo

    2014-05-01

    Pseudomonas savastanoi pv. savastanoi NCPPB 3335 causes olive knot disease and is a model pathogen for exploring bacterial infection of woody hosts. The type III secretion system (T3SS) effector repertoire of this strain includes 31 effector candidates plus two novel candidates identified in this study which have not been reported to translocate into plant cells. In this work, we demonstrate the delivery of seven NCPPB 3335 effectors into Nicotiana tabacum leaves, including three proteins from two novel families of the P. syringae complex effector super-repertoire (HopBK and HopBL), one of which comprises two proteins (HopBL1 and HopBL2) that harbor a SUMO protease domain. When delivered by P. fluorescens heterologously expressing a P. syringae T3SS, all seven effectors were found to suppress the production of defense-associated reactive oxygen species. Moreover, six of these effectors, including the truncated versions of HopAA1 and HopAZ1 encoded by NCPPB 3335, suppressed callose deposition. The expression of HopAZ1 and HopBL1 by functionally effectorless P. syringae pv. tomato DC3000D28E inhibited the hypersensitive response in tobacco and, additionally, expression of HopBL2 by this strain significantly increased its competitiveness in N. benthamiana. DNA sequences encoding HopBL1 and HopBL2 were uniquely detected in a collection of 31 P. savastanoi pv. savastanoi strains and other P. syringae strains isolated from woody hosts, suggesting a relevant role of these two effectors in bacterial interactions with olive and other woody plants.

  5. Life cycle assessment study of solar PV systems: An example of a 2.7kW{sub p} distributed solar PV system in Singapore

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, R.; Leong, K.C.; Osman, R.; Ho, H.K. [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Tso, C.P. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450 Melaka (Malaysia)

    2006-05-15

    In life cycle assessment (LCA) of solar PV systems, energy pay back time (EPBT) is the commonly used indicator to justify its primary energy use. However, EPBT is a function of competing energy sources with which electricity from solar PV is compared, and amount of electricity generated from the solar PV system which varies with local irradiation and ambient conditions. Therefore, it is more appropriate to use site-specific EPBT for major decision-making in power generation planning. LCA and life cycle cost analysis are performed for a distributed 2.7kW{sub p} grid-connected mono-crystalline solar PV system operating in Singapore. This paper presents various EPBT analyses of the solar PV system with reference to a fuel oil-fired steam turbine and their greenhouse gas (GHG) emissions and costs are also compared. The study reveals that GHG emission from electricity generation from the solar PV system is less than one-fourth that from an oil-fired steam turbine plant and one-half that from a gas-fired combined cycle plant. However, the cost of electricity is about five to seven times higher than that from the oil or gas fired power plant. The environmental uncertainties of the solar PV system are also critically reviewed and presented. (author)

  6. Calculation Method and Analysis for the Annual Power Generation of PV Façades in China

    Institute of Scientific and Technical Information of China (English)

    Shen Xu; ZhongMing Hu; Jian Kang; Wei Liao; Jing Huang

    2014-01-01

    The application of PV façades emerges greatly in recent years and however its calculation methods and analysis remains insufficient under the weather conditions of China. In such demand, this paper investigates PV façade in terms of PV electricity generation in different arrangements and weather conditions of four major cities in China. The calculation models for PV façade are developed and validated by comparing the results with the measured data from the field experiments. A parametric study is carried out to provide a reference for the optimal design of the PV façades. The results show that with various cities, building orientations, building forms, materials and arrangements of PV modules, there is a distinct difference in the electrical output energy of PV façades. Weather conditions play a very important role in terms of PV generation performance of PV façades.

  7. Distribution System Augmented by DC Links for Increasing the Hosting Capacity of PV Generation

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Demirok, Erhan; Teodorescu, Remus

    2012-01-01

    This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further, they are cha......This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further...

  8. Comparative Analysis and Considerations for PV Interconnection Standards in the United States and China

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-01-01

    The main objectives of this report are to evaluate China's photovoltaic (PV) interconnection standards and the U.S. counterparts and to propose recommendations for future revisions to these standards. This report references the 2013 report Comparative Study of Standards for Grid-Connected PV System in China, the U.S. and European Countries, which compares U.S., European, and China's PV grid interconnection standards; reviews various metrics for the characterization of distribution network with PV; and suggests modifications to China's PV interconnection standards and requirements. The recommendations are accompanied by assessments of four high-penetration PV grid interconnection cases in the United States to illustrate solutions implemented to resolve issues encountered at different sites. PV penetration in China and in the United States has significantly increased during the past several years, presenting comparable challenges depending on the conditions of the grid at the point of interconnection; solutions are generally unique to each interconnected PV installation or PV plant.

  9. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Roger R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Balfour, John R. [High Performance PV, Phoenix, AZ (United States)

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  10. Dynamic response evaluation of sensorless MPPT method for hybrid PV-DFIG wind turbine system

    Directory of Open Access Journals (Sweden)

    Danvu Nguyen

    2016-01-01

    Full Text Available This research proposes a sensorless Maximum Power Point Tracking (MPPT method for a hybrid Photovoltaic-Wind system, which consists of Photovoltaic (PV system and Doubly-Fed Induction Generator (DFIG Wind Turbine. In the hybrid system, the DC/DC converter output of the PV system is directly connected to the DC-link of DFIG’s back-to-back converter. Therefore, the PV inverter and its associated circuit can be removed in this structure. Typically, the PV power is monitored by using PV current sensor and PV voltage sensor for MPPT. In this paper, the powers of converters on grid side and rotor side of DFIG are used to estimate the PV power without the PV current sensor. That can efficiently reduce the cost of the hybrid system. The detailed analysis of the sensorless MPPT method, which includes derived equations and operation response, is also presented in this paper. In addition, an overview of PV-DFIG research in literature is stated to supply comprehensive knowledge of related research.

  11. Intelligent control of PV system on the basis of the fuzzy recurrent neuronet*

    Science.gov (United States)

    Engel, E. A.; Kovalev, I. V.; Engel, N. E.

    2016-04-01

    This paper presents the fuzzy recurrent neuronet for PV system’s control. Based on the PV system’s state, the fuzzy recurrent neural net tracks the maximum power point under random perturbations. The validity and advantages of the proposed intelligent control of PV system are demonstrated by numerical simulations. The simulation results show that the proposed intelligent control of PV system achieves real-time control speed and competitive performance, as compared to a classical control scheme on the basis of the perturbation & observation algorithm.

  12. Determining the Effects of Environment and Atmospheric Parameters on PV Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Micheli, Leonardo; Muller, Matthew; Kurtz, Sarah

    2016-11-21

    The performance losses due to soiling occurring on any photovoltaic (PV) device are caused by a complex mechanism that involves numerous factors and their interactions. For this reason, the present work analyzes the outputs of reference PV cells installed in various locations, with the aim of contributing to the identification of the most important factors influencing the accumulation of dust on a PV surface. Parameters such as the air-quality indexes, the recurrence and the amount of rainfall and the climate zone are investigated and related to the soiling losses of the PV device.

  13. Modeling of PV Systems Based on Inflection Points Technique Considering Reverse Mode

    Directory of Open Access Journals (Sweden)

    Bonie J. Restrepo-Cuestas

    2013-11-01

    Full Text Available This paper proposes a methodology for photovoltaic (PV systems modeling, considering their behavior in both direct and reverse operating mode and considering mismatching conditions. The proposed methodology is based on the inflection points technique with a linear approximation to model the bypass diode and a simplified PV model. The proposed mathematical model allows to evaluate the energetic performance of a PV system, exhibiting short simulation times in large PV systems. In addition, this methodology allows to estimate the condition of the modules affected by the partial shading since it is possible to know the power dissipated due to its operation at the second quadrant.

  14. Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meydbray, J.; Riley, E.; Dunn, L.; Emery, K.; Kurtz, S.

    2012-10-01

    As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

  15. EFFECT OF REFLECTOR APPLICATION ON PV PANEL PERFORMANCE UNDER EGYPTIAN CONDITIONS

    OpenAIRE

    Mamdouh Abbas HELMY; E. M. KHALIFA; A. M. OKSHA; A. W. ELHADDAD

    2014-01-01

    The proposed approach in the present study is to employ a mirror augmented PV solar panel to track the sun and reflect rays on to the PV panel. Its performance was compared with same PV module without reflector under the same environmental conditions. The mirror augmented solar PV panel tracked sun from East to West along the daytime in Winter 2011 with tilt angle0.523 rad (30 deg) for panel and 0.122 rad (7deg) for mirror which are estimated by experiment. The average energy output values of...

  16. Delta Power Control Strategy for Multi-String Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    With a still increasing penetration level of grid-connected PV systems, more advanced active power control functionalities have been introduced in certain grid regulations. A delta power constraint, where a portion of the active power from the PV panels is reserved during operation, is required...... for the entire PV system is achieved. Simulations and experiments have been performed on a 3-kW single-phase grid-connected PV system. The results have confirmed the effectiveness of the delta power control strategy, where the power reserve according to the delta power constraint is achieved under several...

  17. Optimization of SiC-based H5 and Conergy-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The transformerless DC/AC inverters are critical components in the rapidly growing market of grid-connected Photovoltaic (PV) applications. Also, the SiC-based power semiconductors are capable to operate reliably at high operating temperature and switches frequency levels. In this paper, a new...... profitability of the PV system....... design technique is presented for optimizing the switching frequency and structure of the LCL-type output filter in transformerless H5 and Conergy-NPC PV inverters, which employ SiC-type power devices. The design optimization results demonstrate that the optimized SiC-based PV inverters are more...

  18. How to Estimate Demand Charge Savings from PV on Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bird, Lori A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-28

    Rooftop photovoltaic (PV) systems are compensated through retail electricity tariffs - and for commercial and industrial customers, these are typically comprised of three components: a fixed monthly charge, energy charges, and demand charges. Of these, PV's ability to reduce demand charges has traditionally been the most difficult to estimate. In this fact sheet we explain the basics of demand charges, and provide a new method that a potential customer or PV developer can use to estimate a range of potential demand charge savings for a proposed PV system. These savings can then be added to other project cash flows, in assessing the project's financial performance.

  19. Development and implementation of a PV performance monitoring system based on inverter measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Gavriluta, Anamaria Florina; Sera, Dezso

    2016-01-01

    applications the cost of the performance monitoring hardware and implementation is still high. Therefore, we present the practical development and implementation of a low-cost PV performance monitoring system for residential and commercial PV applications, based on the inverter’s own monitoring......Performance monitoring and fault detection systems are becoming more common in large photovoltaic (PV) plants as they can contribute to decreasing operation and maintenance costs, as well as for maximizing plant yield and lifetime. However, in case of residential and smaller commercial PV system...

  20. EFFECT OF REFLECTOR APPLICATION ON PV PANEL PERFORMANCE UNDER EGYPTIAN CONDITIONS

    OpenAIRE

    Mamdouh Abbas HELMY; E. M. KHALIFA; A. M. OKSHA; A. W. ELHADDAD

    2014-01-01

    The proposed approach in the present study is to employ a mirror augmented PV solar panel to track the sun and reflect rays on to the PV panel. Its performance was compared with same PV module without reflector under the same environmental conditions. The mirror augmented solar PV panel tracked sun from East to West along the daytime in Winter 2011 with tilt angle0.523 rad (30 deg) for panel and 0.122 rad (7deg) for mirror which are estimated by experiment. The average energy output values of...

  1. Power Electronic System for Multi-MW PV sites

    DEFF Research Database (Denmark)

    Paasch, Kasper

    for solar inverters is under a severe pressure regarding cost reduction. The main topic of this thesis is the investigation of the potential advantage of applying string inverters with multiple Maximum-Power-Point-trackers (MPPT) in large PV plants compared to the use of one large central inverter with one.......4%. A portable IV-scanning instrument for the fast long term characterization of solar panels was developed as part of the project. Each second a sweep of the IV-characteristics of a solar panel is performed and the result stored for later analysis. The instrument is based on an active load, is optimized...

  2. Weather modeling and forecasting of PV systems operation

    CERN Document Server

    Paulescu, Marius; Gravila, Paul; Badescu, Viorel

    2012-01-01

    In the past decade, there has been a substantial increase of grid-feeding photovoltaic applications, thus raising the importance of solar electricity in the energy mix. This trend is expected to continue and may even increase. Apart from the high initial investment cost, the fluctuating nature of the solar resource raises particular insertion problems in electrical networks. Proper grid managing demands short- and long-time forecasting of solar power plant output. Weather modeling and forecasting of PV systems operation is focused on this issue. Models for predicting the state of the sky, nowc

  3. Spectrally-Selective Photonic Structures for PV Applications

    Directory of Open Access Journals (Sweden)

    Benedikt Bläsi

    2010-01-01

    Full Text Available We review several examples of how spectrally-selective photonic structures may be used to improve solar cell systems. Firstly, we introduce different spectrally-selective structures that are based on interference effects. Examples shown include Rugate filter, edge filter and 3D photonic crystals such as artificial opals. In the second part, we discuss several examples of photovoltaic (PV concepts that utilize spectral selectivity such as fluorescence collectors, upconversion systems, spectrum splitting concepts and the intermediate reflector concept. The potential of spectrally selective filters in the context of solar cells is discussed.

  4. Analysis of Irradiance Models for Bifacial PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Clifford W.; Stein, Joshua S.; Deline, Chris; MacAlpine, Sara; Marion, Bill; Asgharzadeh, Amir; Toor, Fatima

    2016-11-21

    We describe and compare two methods for modeling irradiance on the back surface of rack-mounted bifacial PV modules: view factor models and ray-tracing simulations. For each method we formulate one or more models and compare each model with irradiance measurements and short circuit current for a bifacial module mounted a fixed tilt rack with three other similarly sized modules. Our analysis illustrates the computational requirements of the different methods and provides insight into their practical applications. We find a level of consistency among the models which indicates that consistent models may be obtained by parameter calibrations.

  5. Silicon shortage: supply constraints limit PV growth until 2008

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, H.; Bradford, T. [Prometheus Inst. (United States)

    2006-10-01

    It is argued that a shortage of refined (polycystalline) silicon will curtail the expansion of the solar photovoltaics industry until about 2008. At present, 94% of PV cells produced worldwide use refined silicon. The problem has arisen because the traditional source, scrap silicon from the electronics industry, is no longer available in sufficient quantities - demand has outstripped supply. Although plans are in place to double the present supply of silicon over the next four years, doubts are expressed over the likelihood of this happening. Currently, there are only seven big companies producing the silicon - production figures for these companies are given. (author)

  6. Testing Interconnections using Conductive Adhesives for Application in PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Broek, K.M.; De Jong, P.C.; Kloos, M.J.H. [ECN Solar Energy, Petten (Netherlands); Van den Nieuwenhof, M.A.C.J.; Bots, T.L.; Meuwissen, M.H.H.; Steijvers, H.L.A.H. [TNO Science and Industry, Eindhoven (Netherlands)

    2006-09-15

    In current module production the electrical interconnections are soldered to the solar cells. For current modules with thin cells and new module concepts with back contact cells, the replacement of solder by conductive adhesives can be advantageous. However, the current IEC tests were developed for soldered interconnections, which have other failure mechanisms. Therefore, three additional tests have been developed for the testing of conductive adhesives to be used in solar modules. In combination with computer simulation techniques developed in the same project, the tests will contribute to a better understanding of failure mechanisms of PV modules with conductive adhesives.

  7. Glyceraldehyde-3-phosphate dehydrogenase of Xanthomonas campestris pv. campestris is required for extracellular polysaccharide production and full virulence.

    Science.gov (United States)

    Lu, Guang-Tao; Xie, Jia-Ri; Chen, Lei; Hu, Jiang-Ru; An, Shi-Qi; Su, Hui-Zhao; Feng, Jia-Xun; He, Yong-Qiang; Jiang, Bo-Le; Tang, Dong-Jie; Tang, Ji-Liang

    2009-05-01

    Glyceraldehyde-3-phosphate dehydrogenase (GAPDH) plays an important role in glucose catabolism, converting glyceraldehyde 3-phosphates to 1,3-bisphosphoglycerates. Open reading frame (ORF) XC_0972 in the genome of Xanthomonas campestris pv. campestris (Xcc) strain 8004 is the only ORF in this strain annotated to encode a GAPDH. In this work, we have demonstrated genetically that this ORF encodes a unique GAPDH in Xcc strain 8004, which seems to be constitutively expressed. A GAPDH-deficient mutant could still grow in medium with glucose or other sugars as the sole carbon source, and no phosphofructokinase activity was detectable in strain 8004. These facts suggest that Xcc may employ the Entner-Doudoroff pathway, but not glycolysis, to utilize glucose. The mutant could not utilize pyruvate as sole carbon source, whereas the wild-type could, implying that the GAPDH of Xcc is involved in gluconeogenesis. Furthermore, inactivation of the Xcc GAPDH resulted in impairment of bacterial growth and virulence in the host plant, and reduction of intracellular ATP and extracellular polysaccharide (EPS). This reveals that GAPDH is required for EPS production and full pathogenicity of Xcc.

  8. Comparative ultrastructure of nonwounded Mexican lime and Yuzu leaves infected with the citrus canker bacterium Xanthomonas citri pv. citri.

    Science.gov (United States)

    Lee, In Jung; Kim, Ki Woo; Hyun, Jae Wook; Lee, Yong Hoon; Park, Eun Woo

    2009-07-01

    Ultrastructural aspects of citrus canker development were investigated in nonwounded leaves of citrus species by transmission electron microscopy (TEM). A susceptible species Mexican lime and a resistant species Yuzu were spray-inoculated with a virulent strain of Xanthomonas citri pv. citri. Initial symptoms occurred on Mexican lime approximately 9 days after inoculation, whereas they appeared on Yuzu mostly 11 days after inoculation. In Mexican lime leaves, the bacterial invasion was usually accompanied by host cell wall dissolution and cellular disruption. Fibrillar materials from degenerated cell walls were usually found in intercellular spaces. Damaged host cells with necrotic cytoplasm showed the localized separation of plasma membrane from the cell wall. Bacterial multiplication and electron-transparent capsule-like structures around bacteria were commonly observed. Meanwhile, cell wall protuberances were prominent outside host cell walls in response to bacterial invasion in Yuzu leaves. Occlusion of intercellular spaces was also formed by the fusion of two or more individual cell wall protuberances originated from two adjacent host cells. Papillae-like materials accumulated locally within host cells in close proximity to bacteria. Some bacteria were found to be undergoing degeneration in xylem vessels. Also, the shrunken, inactive bacteria were surrounded by electron-translucent fibrillar materials in intercellular spaces, implying bacterial immobilization. These cellular responses are thought to be the consequences of defense responses of Yuzu leaves to invading bacteria. In both citrus species, X. citri pv. citri contained polyphosphate bodies showing electron-dense and elliptical structures in cytoplasm.

  9. Temperature Dependences on Various Types of Photovoltaic (PV) Panel

    Science.gov (United States)

    Audwinto, I. A.; Leong, C. S.; Sopian, K.; Zaidi, S. H.

    2015-09-01

    Temperature is one of the key roles in PV technology performance, since with the increases of temperature the open-circuit voltage will drop accordingly so do the electrical efficiency and power output generation. Different types of Photovoltaic (PV) panels- silicon solar panels and thin film solar panels; mono-crystalline, poly-crystalline, CIS, CIGS, CdTe, back-contact, and bi-facial solar panel under 40°C to 70°C approximately with 5°C interval have been comparatively analyzed their actual performances with uniformly distribution of light illumination from tungsten halogen light source, ±500W/m2. DC-Electronic Load and Data Logger devices with “Lab View” data program interface were used to collect all the necessary parameters in this study. Time needed to achieve a certain degree of temperature was recorded. Generally, each of the panels needed 15 minutes to 20 minutes to reach 70°C. Halogen based light source is not compatible in short wave-length in response to thin-film solar cell. Within this period of times, all the panels are facing a performance loss up to 15%. Other parameters; Pmax, Vmax, Imax, Voc, Isc, Rserries, Rshunt, Fillfactor were collected as study cases. Our study is important in determining Photovoltaic type selection and system design as for study or industrial needed under different temperature condition.

  10. Assuring long-term reliability of concentrator PV systems

    Science.gov (United States)

    McConnell, R.; Garboushian, V.; Brown, J.; Crawford, C.; Darban, K.; Dutra, D.; Geer, S.; Ghassemian, V.; Gordon, R.; Kinsey, G.; Stone, K.; Turner, G.

    2009-08-01

    Concentrator PV (CPV) systems have attracted significant interest because these systems incorporate the world's highest efficiency solar cells and they are targeting the lowest cost production of solar electricity for the world's utility markets. Because these systems are just entering solar markets, manufacturers and customers need to assure their reliability for many years of operation. There are three general approaches for assuring CPV reliability: 1) field testing and development over many years leading to improved product designs, 2) testing to internationally accepted qualification standards (especially for new products) and 3) extended reliability tests to identify critical weaknesses in a new component or design. Amonix has been a pioneer in all three of these approaches. Amonix has an internal library of field failure data spanning over 15 years that serves as the basis for its seven generations of CPV systems. An Amonix product served as the test CPV module for the development of the world's first qualification standard completed in March 2001. Amonix staff has served on international standards development committees, such as the International Electrotechnical Commission (IEC), in support of developing CPV standards needed in today's rapidly expanding solar markets. Recently Amonix employed extended reliability test procedures to assure reliability of multijunction solar cell operation in its seventh generation high concentration PV system. This paper will discuss how these three approaches have all contributed to assuring reliability of the Amonix systems.

  11. Islanding Issues of Grid-connected PV Systems

    Directory of Open Access Journals (Sweden)

    S.Narendiran

    2013-04-01

    Full Text Available ‘Islanding’ is a term, which refers to the situation when the Distributed generator (DG continues to power the consumer-end even when the electrical power from the electric utility is no longerpresent. Islanding phenomenon occurs after the certain part of the utility grid gets disconnected from a large number of inter-connected PVs. It leads to troubles in voltage and frequency control and powerquality issues. Therefore there is a need for appropriate anti-islanding measures for grid-connected PV systems. There are two ways to defeat the islanding phenomenon, by reactor insertion method on utility side and capacitor insertion method on PV side. Some of the Islanding detection methods (IDMs are broadly classifies as Active, Passive and Utility based. Active mode of detection includes impedance measurement, slip mode frequency shift and frequency bias. Passive methods contain over/under voltage and frequency and harmonics detection. Utility-based methods consist of manual disconnection, SCADA, impedance insertion.

  12. Trimode Power Converter optimizes PV, diesel and battery energy sources

    Science.gov (United States)

    Osullivan, George; Bonn, Russell; Bower, Ward

    1994-12-01

    Conservatively, there are 100,000 localities in the world waiting for the benefits that electricity can provide, and many of these are in climates where sunshine is plentiful. With these locations in mind a prototype 30 kW hybrid system has been assembled at Sandia to prove the reliability and economics of photovoltaic, diesel and battery energy sources managed by an autonomous power converter. In the Trimode Power Converter the same power parts, four IGBT's with an isolation transformer and filter components, serve as rectifier and charger to charge the battery from the diesel; as a stand-alone inverter to convert PV and battery energy to AC; and, as a parallel inverter with the diesel-generator to accommodate loads larger than the rating of the diesel. Whenever the diesel is supplying the load, an algorithm assures that the diesel is running at maximum efficiency by regulating the battery charger operating point. Given the profile of anticipated solar energy, the cost of transporting diesel fuel to a remote location and a five year projection of load demand, a method to size the PV array, battery and diesel for least cost is developed.

  13. Curtobacterium flaccumfaciens pv. flaccumfaciens: etiology, detection and control strategies

    Directory of Open Access Journals (Sweden)

    Giseli Valentini

    2010-12-01

    Full Text Available The diseases caused by bacteria present a phytopathological and agricultural problem in various economic crops. The Curtobacterium wilt caused by Curtobacterium fl accumfaciens pv. fl accumfaciens has become a threat to the cultivation of beans (Phaseolus vulgaris L.. The disease statement for the Brazilian territory occurred in 1995 and today the pathogen is distributed in various Brazilian producing regions. Transmission is primarily via contaminated seed, which imposes great diffi culties and limitations on the control of these bacteria. After plant infection, the only way to control it is the eradication of infected plants. The alternatives for the control of this disease are the use of healthy seeds, crop rotation and resistant varieties. The use of resistant varieties is the most effi cient and economical solution for the farmer. The most important research to support the development of bean cultivars resistant to C. fl accumfaciens pv. fl accumfaciens is the identifi cation of sources of genetic resistance and the study of mechanisms of genetic resistance to disease.

  14. Sizing and Simulation of PV-Wind Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2013-01-01

    Full Text Available A sizing procedure is developed for hybrid system with the aid of mathematical models for photovoltaic cell, wind turbine, and battery that are readily present in the literature. This sizing procedure can simulate the annual performance of different kinds of photovoltaic-wind hybrid power system structures for an identified set of renewable resources, which fulfills technical limitations with the lowest energy cost. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Security lightning application is selected, whereas system performance data and environmental operating conditions are measured and stored. This hybrid system, which includes a PV, wind turbine, inverter, and a battery, was installed to supply energy to 24 W lamps, considering that the renewable energy resources of this site where the system was installed were 1700 Wh/m2/day solar radiation and 3.43 m/s yearly average wind speed. Using the measured variables, the inverter and charge regulator efficiencies were calculated as 90% and 98%, respectively, and the overall system’s electrical efficiency is calculated as 72%. Life cycle costs per kWh are found to be $0.89 and LLP = 0.0428.

  15. A control strategy for PV stand-alone applications

    Science.gov (United States)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  16. Transforming PV installations toward dispatchable, schedulable energy solutions

    Energy Technology Data Exchange (ETDEWEB)

    Scharf, Mesa [AE Solar Energy, Inc., Ft. Collins, Co (United States)

    2015-06-15

    The Advanced Energy led SEGIS-AC program represents an industry partnership driven collaborative effort to continue to lower the barriers to increasing penetration of PV on the grid while also lowering overall system cost consistent with the Department of Energy SunShot Initiative. The SEGIS-AC program follows the DOE sponsored three year SEGIS program, which had similar high level goals, but with a broader exploratory scope. In SEGIS-AC, the team carries forward a new communications based islanding detection technology developed during the SEGIS program. Advanced utility interactive controls are further developed, and a storage inverter system is developed focused on intermittency mitigation due to cloud induced transients. Communications based island detection coupled with advanced controls and a storage system are shown to improve utility distribution feeder performance and to enable increased solar PV penetration levels. By the conclusion of the program, multiple utilities and customers have expressed awareness and desire to make use of the technologies developed and demonstrated under this program. This factor has led the Advanced Energy led team to deem the program an overall success. The report following details the technologies developed and demonstrated, as well as industry engagement.

  17. Fire risk related to the use of PV systems in building facades

    Directory of Open Access Journals (Sweden)

    Mazziotti Lamberto

    2016-01-01

    Full Text Available Nowadays the use of photovoltaic (PV systems in buildings is not only related to the solar energy conversion into electrical one, but these PV modules or panels could also be used with aesthetic features or, even more, as thermal protection systems in building facades. Thanks to the technical development of the photovoltaic industry, PV system can easily be architectonically integrated into building construction elements such as roofs, vertical façade components, both with opaque or transparent surfaces. Furthermore, PV construction facades elements could also be provided by openings like doors or windows. Accident analysis show that the use of PV systems as construction elements could increase the risk of fire in buildings. In fact, international and National data report a growing number of fire caused by PV system applied or integrated in buildings. The Italian National Fire Service, that is the Authority having jurisdiction for fire safety in buildings (in Italy, in 2012 has released a Guideline in order to asses and mitigate the risk of fire when a PV system is put in place on a building as a façade or as a roof. The Guideline addresses not only the reduction of the PV fire ignitions causes and the aspects related to the fire spread due to the combustible parts that constitute PV modules or panels, but also take into account the safety of both the maintenance personnel and the rescue teams. This paper focuses on the fire safety aspects related to the use of fire PV panels and systems in building facades, showing some interesting experimental data related to the fire behaviour of these components and underlining the factors that promote the spread of fire, like the high operating temperature of the PV system itself.

  18. Development of a New Semiselective Medium for Isolating Xanthomonas campestris pv. manihotis from Plant Material and Soil.

    Science.gov (United States)

    Fessehaie, A; Wydra, K; Rudolph, K

    1999-07-01

    ABSTRACT An effective control for bacterial blight of cassava (Manihot esculenta), caused by Xanthomonas campestris pv. manihotis, requires the use of non-contaminated cuttings and seeds. Using classical agar plating techniques for screening planting material for contamination has not been very successful because of the lack of a reliable semiselective agar medium. The pathogen grows slowly on general plating media and is easily overgrown by saprophytic bacteria during isolation from diseased plants. In an effort to develop a semiselective medium, the utilization of several carbon and nitrogen sources was studied. Results of these tests provided information used to design a basal medium allowing good growth of the target organism while suppressing growth of several common saprophytes. Additional selectivity was achieved by incorporating three antibiotics into the basal medium. The new semiselective agar medium, designated cefazolin trehalose agar (CTA) medium, contained (per liter) 3.0 g of K(2)HPO(4), 1.0 g of NaH(2)PO(4), 0.3 g of MgSO(4).7H(2)O, 1.0 g of NH(4)Cl, 9.0 g of D(+)-trehalose, 1.0 D(+)-glucose, 1.0 g of yeast extract, 0.025 g of cefazolin, 0.0012 g of lincomycin, 0.0025 g of phosphomycin, 0.25 g of cycloheximide, and 14.0 g of agar. In comparison to a starch-based semiselective medium (SXM), plating efficiencies using pure cultures of 10 strains of X. campestris pv. manihotis were significantly higher on CTA, with an average of 85 and 50%, respectively. Likewise, isolation and recovery of X. campestris pv. manihotis from infected cassava leaves and contaminated soil were much higher on CTA than on SXM agar. When X. campestris pv. manihotis occurs in high concentrations in diseased tissue, the standard yeast trehalose glucose agar medium supplemented with 250 mug of cycloheximide per ml appears to be satisfactory. The newly developed CTA medium should prove useful for control strategies to identify and remove infected planting material of cassava, as

  19. Structural-functional characterization and physiological significance of ferredoxin-NADP reductase from Xanthomonas axonopodis pv. citri.

    Science.gov (United States)

    Tondo, María Laura; Musumeci, Matías A; Delprato, María Laura; Ceccarelli, Eduardo A; Orellano, Elena G

    2011-01-01

    Xanthomonas axonopodis pv. citri is a phytopathogen bacterium that causes severe citrus canker disease. Similar to other phytopathogens, after infection by this bacterium, plants trigger a defense mechanism that produces reactive oxygen species. Ferredoxin-NADP(+) reductases (FNRs) are redox flavoenzymes that participate in several metabolic functions, including the response to reactive oxygen species. Xanthomonas axonopodis pv. citri has a gene (fpr) that encodes for a FNR (Xac-FNR) that belongs to the subclass I bacterial FNRs. The aim of this work was to search for the physiological role of this enzyme and to characterize its structural and functional properties. The functionality of Xac-FNR was tested by cross-complementation of a FNR knockout Escherichia coli strain, which exhibit high susceptibility to agents that produce an abnormal accumulation of (•)O(2)(-). Xac-FNR was able to substitute for the FNR in E. coli in its antioxidant role. The expression of fpr in X. axonopodis pv. citri was assessed using semiquantitative RT-PCR and Western blot analysis. A 2.2-fold induction was observed in the presence of the superoxide-generating agents methyl viologen and 2,3-dimethoxy-1,4-naphthoquinone. Structural and functional studies showed that Xac-FNR displayed different functional features from other subclass I bacterial FNRs. Our analyses suggest that these differences may be due to the unusual carboxy-terminal region. We propose a further classification of subclass I bacterial FNRs, which is useful to determine the nature of their ferredoxin redox partners. Using sequence analysis, we identified a ferredoxin (XAC1762) as a potential substrate of Xac-FNR. The purified ferredoxin protein displayed the typical broad UV-visible spectrum of [4Fe-4S] clusters and was able to function as substrate of Xac-FNR in the cytochrome c reductase activity. Our results suggest that Xac-FNR is involved in the oxidative stress response of Xanthomonas axonopodis pv. citri and

  20. Structural-functional characterization and physiological significance of ferredoxin-NADP reductase from Xanthomonas axonopodis pv. citri.

    Directory of Open Access Journals (Sweden)

    María Laura Tondo

    Full Text Available Xanthomonas axonopodis pv. citri is a phytopathogen bacterium that causes severe citrus canker disease. Similar to other phytopathogens, after infection by this bacterium, plants trigger a defense mechanism that produces reactive oxygen species. Ferredoxin-NADP(+ reductases (FNRs are redox flavoenzymes that participate in several metabolic functions, including the response to reactive oxygen species. Xanthomonas axonopodis pv. citri has a gene (fpr that encodes for a FNR (Xac-FNR that belongs to the subclass I bacterial FNRs. The aim of this work was to search for the physiological role of this enzyme and to characterize its structural and functional properties. The functionality of Xac-FNR was tested by cross-complementation of a FNR knockout Escherichia coli strain, which exhibit high susceptibility to agents that produce an abnormal accumulation of (•O(2(-. Xac-FNR was able to substitute for the FNR in E. coli in its antioxidant role. The expression of fpr in X. axonopodis pv. citri was assessed using semiquantitative RT-PCR and Western blot analysis. A 2.2-fold induction was observed in the presence of the superoxide-generating agents methyl viologen and 2,3-dimethoxy-1,4-naphthoquinone. Structural and functional studies showed that Xac-FNR displayed different functional features from other subclass I bacterial FNRs. Our analyses suggest that these differences may be due to the unusual carboxy-terminal region. We propose a further classification of subclass I bacterial FNRs, which is useful to determine the nature of their ferredoxin redox partners. Using sequence analysis, we identified a ferredoxin (XAC1762 as a potential substrate of Xac-FNR. The purified ferredoxin protein displayed the typical broad UV-visible spectrum of [4Fe-4S] clusters and was able to function as substrate of Xac-FNR in the cytochrome c reductase activity. Our results suggest that Xac-FNR is involved in the oxidative stress response of Xanthomonas axonopodis pv