WorldWideScience

Sample records for purge valve isolation

  1. Whitey Swagelok SCHe Ball Valves Provide Isolation between SCHe Purge Lines C and D and the Process Vent

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They provide an isolation function betwen SCHe Purge Line C, (PV-V-*079), and Purge Line D, (PV-V-*080), and the Process Vent.

  2. Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Hackett, D.B.

    1980-01-01

    This report documents the technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun nuclear power plant. The review criteria are based on IEEE Std-279-1971 requirements for the safety signals to all purge and ventilation isolation valves. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Program being conducted for the US Nuclear Regulatory Commission by Lawrence Livermore Laboratory.

  3. 49 CFR 193.2615 - Isolating and purging.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Isolating and purging. 193.2615 Section 193.2615...: FEDERAL SAFETY STANDARDS Maintenance § 193.2615 Isolating and purging. (a) Before personnel begin... component must be purged in accordance with a procedure which meets the requirements of AGA...

  4. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  5. Steam and fuel oil supply and purge valve with cooling steam feature

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, B.F.; Buchanan, J.R.

    1991-09-17

    This patent describes a steam and fuel oil supply and purge valve. It comprises a valve body defining steam and oil inlet ports, at least one discharge port, a steam purge passageway interconnecting the steam inlet and discharge ports, an oil supply passageway interconnecting the oil inlet and discharge ports, a cooling steam passageway interconnecting the steam inlet and discharge ports, a steam valve and actuator member movable between first, second, third, and fourth positions in the valve body and operable to open and close the steam purge and cooling steam passageways, a small metering passageway in the steam valve and actuator member which is so dimensioned and located as to open prior to full opening movement of the valve member and actuator relative to its seat, an oil valve member movable between first and second positions to open and close the oil supply passageway, biasing means urging the oil valve member toward its second and closed positions, the steam valve and actuator member in its first and second positions respectively closing and opening the steam purge passageway.

  6. Tri-leaflet valve design with a purge flow for heart-assist devices: an in vitro optimization study.

    Science.gov (United States)

    Timmel, Tobias; Seshadri, Santhosh; Goubergrits, Leonid; Affeld, Klaus; Kertzscher, Ulrich

    2012-01-01

    The objective of this study is to assess the effect of a purge flow on valves of pulsatile heart-assist devices. Clinical applications of these devices are still limited because of frequent thromboembolic complications. These complications often originate at the valves and the unavoidable flow separation regions that are found behind the leaflets. The flow separations cause a long residence time of blood that is considered particularly detrimental. To solve this problem, a valve with a purge flow is proposed. A purge flow is a jet, which is separated from the main blood flow and directed behind the leaflets into the sinus to flush it. Even though the purge flow does not prevent a flow separation, it shortens the residence time of the blood in the sinus. Thus, the purge flow improves the periodic washout of the blood in the region of flow separation. The complex purge flow was investigated in a tri-leaflet valve. The geometrical parameters of the valve were varied systematically. A statistical technique--the Taguchi method--was used to reduce the number of investigated models to 12. The flows through the resulting valve models were numerically simulated and analyzed. The evaluated models with the best results were subsequently investigated experimentally using different methods: hemodynamic tests in a valve tester and flow visualization using the dye washout method. It was shown that the purge flow can effectively wash out the sinus. Therefore, the purge flow valve reduces the potential of a thrombus formation normally associated with the valve.

  7. A synthetic biochemistry molecular purge valve module that maintains redox balance.

    Science.gov (United States)

    Opgenorth, Paul H; Korman, Tyler P; Bowie, James U

    2014-06-17

    The greatest potential environmental benefit of metabolic engineering would be the production of high-volume commodity chemicals, such as biofuels. Yet, the high yields required for the economic viability of low-value chemicals is particularly hard to achieve in microbes owing to the myriad competing biochemical pathways. An alternative approach, which we call synthetic biochemistry, is to eliminate the organism by constructing biochemical pathways in vitro. Viable synthetic biochemistry, however, will require simple methods to replace the cellular circuitry that maintains cofactor balance. Here we design a simple purge valve module for maintaining NADP(+)/NADPH balance. We test the purge valve in the production of polyhydroxybutyryl bioplastic and isoprene--pathways where cofactor generation and utilization are unbalanced. We find that the regulatory system is highly robust to variations in cofactor levels and readily transportable. The molecular purge valve provides a step towards developing continuously operating, sustainable synthetic biochemistry systems.

  8. Propellant isolation shutoff valve program

    Science.gov (United States)

    Merritt, F. L.

    1973-01-01

    An analysis and design effort directed to advancing the state-of-the-art of space storable isolation valves for control of flow of the propellants liquid fluorine/hydrazine and Flox/monomethylhydrazine is discussed. Emphasis is on achieving zero liquid leakage and capability of withstanding missions up to 10 years in interplanetary space. Included is a study of all-metal poppet sealing theory, an evaluation of candidate seal configurations, a valve actuator trade-off study and design description of a pneumo-thermally actuated soft metal poppet seal valve. The concepts and analysis leading to the soft seal approach are documented. A theoretical evaluation of seal leakage versus seal loading, related finishes and yield strengths of various materials is provided. Application of a confined soft aluminum seal loaded to 2 to 3 times yield strength is recommended. Use of either an electro-mechanical or pneumatic actuator appears to be feasible for the application.

  9. Conserving Purge Gases

    Science.gov (United States)

    Kan, K.; Blewett, L.; Nelson, T.

    1985-01-01

    Two-step flow control adjusts to dimensional changes in purged equipment. Two pressure actuated valves provide two-step control. When turbopump starts, helium flows through both valves. As pump operates its parts expand, clearance decrease and back pressure builds up on valves. At preset back pressure value, one valve closes, reducing helium flow.

  10. Bistable (latching) solenoid actuated propellant isolation valve

    Science.gov (United States)

    Wichmann, H.; Deboi, H. H.

    1979-01-01

    The design, fabrication, assembly and test of a development configuration bistable (latching) solenoid actuated propellant isolation valve suitable for the control hydrazine and liquid fluorine to an 800 pound thrust rocket engine is described. The valve features a balanced poppet, utilizing metal bellows, a hard poppet/seat interface and a flexure support system for the internal moving components. This support system eliminates sliding surfaces, thereby rendering the valve free of self generated particles.

  11. Hepatocytes isolated from neoplastic liver-immunomagnetic purging as a new source for transplantation

    Institute of Scientific and Technical Information of China (English)

    Aravin Gunasegaram; Javed Akhter; Peng Yao; Loreena A Johnson; Stephen M Riodan; David L Morris

    2008-01-01

    AIM: To investigate whether hepatocytes isolated from macroscopically normal liver during hepatic resection for neoplasia could provide a novel source of healthy hepatocytes, including the development of reliable protocols for malignant cells removal from the hepatocyte preparation.METHODS: Hepatocytes were procured from resected liver of 18 patients with liver tumors using optimised digestion and cell-enrichment protocols. Suspensions of various known quantities of the HT-29 tumor cell line and patient hepatocytes were treated or not with Ep-CAM-antibody-coated immunomagnetic beads in order to investigate the efficacy of tumor-purging by immunomagnetic depletion, using a semi-quantitative RT-PCR method developed to detect tumor cells.Immunomagnetic bead-treated or bead-untreated tumor cell-hepatocyte suspensions were transplanted intra-peritoneally in Balb/C nude mice to assess the rates of tumor development.RESULTS: Mean viable hepatocyte yield was 9.3 x 106 cells per gram of digested liver with mean viability of 70.5%. Immunomagnetic depletion removed tumor cells to below the RT-PCR detection-threshold of 1 tumor cell in 106 hepatocytes, representing a maximum tumor purging efficacy of greater than 400000-fold.Transplanted, immunomagnetic bead-purged tumor cell-hepatocyte suspensions did not form peritoneal tumors in Balb/C nude mice. Co-transplantation of hepatocytes with tumor cells did not increase tumorigenesis of the tumor cells.CONCLUSION: Immunomagnetic depletion appears to be an effective method of purging contaminating tumor cells to below threshold for likely tumorigenesis.Along with improved techniques for isolation of large numbers of viable hepatocytes, normal liver resected for neoplasia has potential as another clinically useful source of hepatocytes for transplantation.

  12. 46 CFR 153.980 - Isolation of automatic closing valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Isolation of automatic closing valves. 153.980 Section... Transfer Procedures § 153.980 Isolation of automatic closing valves. The person in charge of cargo transfer may isolate automatic closing valves described in § 153.408(b) from a cargo containment system if...

  13. Whitey SCHe Ball Valves Provide Test Port Isolation

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

  14. Shape Memory Alloy Isolation Valves: Public Quad Chart

    Science.gov (United States)

    2017-05-12

    NUMBER (Include area code) 12 May 2017 Briefing Charts 12 April 2017 - 12 May 2017 Shape Memory Alloy Isolation Valves: Public Quad Chart William...spacecraft (15+ yrs) • Shaped memory alloy isolation valves provide an intrinsically safe isolation system that increases lifetime >5x over SOTA and... Shape Memory Alloy Isolation Valves POC: W. Hargus, Ph.D., AFRL/RQRC B-52 Teardrop Antenna Depolymerization WC-130J Leading Edge Erosion Distribution

  15. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  16. Coal slurry fuel supply and purge system

    Science.gov (United States)

    McDowell, Robert E.; Basic, Steven L.; Smith, Russel M.

    1994-01-01

    A coal slurry fuel supply and purge system for a locomotive engines is disclosed which includes a slurry recirculation path, a stand-by path for circulating slurry during idle or states of the engine when slurry fuel in not required by the engine, and an engine header fluid path connected to the stand-by path, for supplying and purging slurry fuel to and from fuel injectors. A controller controls the actuation of valves to facilitate supply and purge of slurry to and from the fuel injectors. A method for supplying and purging coal slurry in a compression ignition engine is disclosed which includes controlling fluid flow devices and valves in a plurality of fluid paths to facilitate continuous slurry recirculation and supply and purge of or slurry based on the operating state of the engine.

  17. Isolated pulmonic valve endocarditis presenting as neck pain

    Directory of Open Access Journals (Sweden)

    Aditya Goud

    2015-12-01

    Full Text Available We discuss a unique case of a 52-year-old man with no history of intravenous drug use or dental procedures who presented with neck pain, 2 weeks of fevers, chills, night sweats, cough, and dyspnea found to have isolated pulmonic valve (PV endocarditis. The patient did not have an associated murmur, which is commonly seen in right-sided infectious endocarditis. A transthoracic echocardiogram showed a thickened PV leaflet, with subsequent transesophageal echocardiogram showing a PV mass. Speciation of blood cultures revealed Streptococcus oralis. In right-sided infective endocarditis, usually the tricuspid valve is involved; however, in our case the tricuspid valve was free of any mass or vegetation. The patient did meet Duke criteria and was thus started on long-term intravenous antibiotics for infectious endocarditis. The patient's symptoms quickly improved with antibiotics. A careful history and evaluating the patient's risk factors are key in earlier detection of infective endocarditis (IE. Because of early detection and a high index of suspicion, the patient had no further complications and did not require any surgery. In conclusion, clinical suspicion of right-sided IE should be high in patients who present with persistent fevers and pulmonary symptoms in order to reduce the risk of complications, and to improve outcomes.

  18. Pressure-control purge panel for automatic butt welding

    Science.gov (United States)

    Lang, E. J.; Van Wagner, B. H.

    1969-01-01

    Modification of a purge panel for use in an automatic butt weld reduces the drop in pressure between the regulators and the weld head and tube purge fitting. The invention affects air regulators for plants, regulating circuits for pneumatic valves, and automatic welding machines.

  19. Shape Memory Actuated Normally Open Permanent Isolation Valve

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Bacha, Caitlin E. (Inventor)

    2017-01-01

    A valve assembly for an in-space propulsion system includes an inlet tube, an outlet tube, a valve body coupling the inlet tube to the outlet tube and defining a propellant flow path, a valve stem assembly disposed within the valve body, an actuator body coupled to the valve body, the valve stem assembly extending from an interior of the valve body to an interior of the actuator body, and an actuator assembly disposed within the actuator body and coupled to the valve stem assembly, the actuator assembly including a shape memory actuator member that when heated to a transition temperature is configured to enable the valve stem assembly to engage the outlet tube and seal the propellant flow path.

  20. Purge corruption detection

    Energy Technology Data Exchange (ETDEWEB)

    Nankee, R.J. II; Frantz, D.C.; Tamm, J.R.; Gutermuth, T.R.

    1989-04-18

    This patent describes an adaptive memory cell update method for the detection and correction of a possible purge corruption of the adaptive memory portion of the memory in an internal combustion engine control unit, the adaptive memory portion having purge free cells and normal cells. The method consists of: determining the adaptive memory cells to be used during the adaptive memory cell update by determining if the engine conditions are right to turn the purge system off; if the conditions are right to turn the purge system off, turning the purge system off and using the purge free cells in the adaptive memory cell update; if the conditions are not right to turn the purge system off, turning the purge system on and using the normal cells in the adaptive memory cell update.

  1. Replacement of outboard main steam isolation valves in a boiling water reactor plant

    Energy Technology Data Exchange (ETDEWEB)

    Schlereth, J.R.; Pennington, D.

    1996-12-01

    Most Boiling Water Reactor plants utilize wye pattern globe valves for main steam isolation valves for both inboard and outboard isolation. These valves have required a high degree of maintenance attention in order to pass the plant local leakage rate testing (LLRT) requirements at each outage. Northern States Power made a decision in 1993 to replace the outboard valves at it`s Monticello plant with double disc gate valves. The replacement of the outboard valves was completed during the fall outage in 1994. During the spring outage in April of 1996 the first LLRT testing was performed with excellent results. This presentation will address the decision process, time requirements and planning necessary to accomplish the task as well as the performance results and cost effectiveness of replacing these components.

  2. Surgical outcomes of isolated tricuspid valve procedures: repair versus replacement.

    Science.gov (United States)

    Ejiofor, Julius I; Neely, Robert C; Yammine, Maroun; McGurk, Siobhan; Kaneko, Tsuyoshi; Leacche, Marzia; Cohn, Lawrence H; Shekar, Prem S

    2017-05-01

    Isolated tricuspid valve (ITV) operations are infrequent and the decision to operate is controversial. We report a series of ITV operations to outline the current disease status requiring this uncommon procedure with an emphasis on the results of tricuspid valve repair (TVr) versus replacement (TVR). Using our prospective cardiac surgery database, 57 patients who underwent ITV operations between 01/02-03/14 were identified. Median follow up time was 3.5 years [interquartile range (IQR), 0.8-6.7 years]. Fifty-seven patients underwent ITV surgery with a mean age of 54.4±14.9 yrs and 61% were women. Baseline characteristics were similar between patients who underwent TVr (n=18) or TVR (n=39). The etiologies of TV dysfunction were: ITV endocarditis 14/57 (25%), persistent TV regurgitation after left-sided valve surgery in 12/57 (21%), traumatic biopsies and iatrogenic injury from pacing leads in 11/57 (19%), orthotopic heart transplant 9/57 (16%), carcinoid syndrome 3/57 (5%), congenital 2/57 (5%) and idiopathic 5/57 (9%). Overall, 32/57 (56%) patients had prior heart surgery; of which 10/32 (31%) were TV procedures. Bioprosthetic prostheses were used in 34/39 (87%) patients. Of those who had repair, 11/18 (61%) had ring annuloplasty, 3/18 (17%) bicuspidization, and 3/18 (17%) De Vega annuloplasty and one had vegetectomy. Operative mortality was 5.1% (n=2) and 16.7% (n=3) for TVR and TVr groups, respectively (P=0.32), with an overall mortality rate of 8.6%. Postoperative complications included new onset renal failure in 6/39 (15%) of TVr and 2/18 (11%) of TVR (P=0.71) and there were no strokes. Overall survival rates and degree of residual RV dysfunction were similar for the two groups (both P=0.3). Five-year survival was 77% and 84% for TVr and TVR respectively (P=0.52). There was no difference in rates of recurrent tricuspid regurgitation for TVr and TVR (35.7% vs. 23.5%, respectively, P=0.4). ITV surgery is associated with improved but still relatively high

  3. Purged window apparatus utilizing heated purge gas

    Science.gov (United States)

    Ballard, Evan O.

    1984-01-01

    A purged window apparatus utilizing tangentially injected heated purge gases in the vicinity of electromagnetic radiation transmitting windows, and a tapered external mounting tube to accelerate these gases to provide a vortex flow on the window surface and a turbulent flow throughout the mounting tube. Use of this apparatus prevents backstreaming of gases under investigation which are flowing past the mouth of the mounting tube which would otherwise deposit on the windows. Lengthy spectroscopic investigations and analyses can thereby be performed without the necessity of interrupting the procedures in order to clean or replace contaminated windows.

  4. Purge water management system

    Science.gov (United States)

    Cardoso-Neto, Joao E.; Williams, Daniel W.

    1996-01-01

    A purge water management system for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  5. Experimental study on the optimal purge duration of a proton exchange membrane fuel cell with a dead-ended anode

    Science.gov (United States)

    Lin, Yu-Fen; Chen, Yong-Song

    2017-02-01

    When a proton exchange membrane fuel cell (PEMFC) is operated with a dead-ended anode, impurities gradually accumulate within the anode, resulting in a performance drop. An anode purge is thereby ultimately required to remove impurities within the anode. A purge strategy comprises purge interval (valve closed) and purge duration (valve is open). A short purge interval causes frequent and unnecessary activation of the valve, whereas a long purge interval leads to excessive impurity accumulation. A short purge duration causes an incomplete performance recovery, whereas a long purge duration results in low hydrogen utilization. In this study, a series of experimental trials was conducted to simultaneously measure the hydrogen supply rate and power generation of a PEMFC at a frequency of 50 Hz for various operating current density levels and purge durations. The effect of purge duration on the cell's energy efficiency was subsequently analyzed and discussed. The results showed that the optimal purge duration for the PEMFC was approximately 0.2 s. Based on the results of this study, a methodical process for determining optimal purge durations was ultimately proposed for widespread application. Purging approximately one-fourth of anode gas can obtain optimal energy efficiency for a PEMFC with a dead-ended anode.

  6. In vitro susceptibility of high virulence microorganisms isolated in heart valve banking.

    Science.gov (United States)

    Villalba, R; Solis, F; Fornés, G; Jimenez, A; Eisman, M; González, Ana I; Linares, M J; Casal, M; Gómez Villagrán, J L

    2012-08-01

    Storage preparation of human heart valves for implants generally includes incubation in an antimicrobial disinfection solution and cryopreservation. Changes in patterns of microorganisms susceptibility to antibiotics is a variable process of that promote its inefficiency. The aim of this study has been an evaluation of in vitro susceptibility of high virulence microorganisms isolated in our tissue bank for 14 years in order to evaluate the efficiency, and to promote changes for further antibiotics mixtures as well. Data presented in this study show that microorganisms isolates in valve banking display susceptibility patterns similar to those shown in other clinical circumstances, and the most commonly used antibiotics regimes are useful to date. An antibiotic cocktail containing aminoglicoside in addition to ciprofloxacin and vancomycin is an efficient mixture to be used in valve banking. Further studies will be necessary for monitoring patterns changes of in vitro susceptibility of microbiological isolates in tissue banking.

  7. Real-time multivariate statistical classification of cells for flow cytometry and cell sorting: a data mining application for stem cell isolation and tumor purging

    Science.gov (United States)

    Leary, James F.; McLaughlin, Scott R.; Reece, Lisa M.; Rosenblatt, Judah I.; Hokanson, James A.

    1999-06-01

    Multivariate statistics can be used for visualization of cell subpopulations in multidimensional data space and for classification of cells within that data space. New data mining techniques we have developed, such as subtractive clustering, can be used to find the differences between test and control multiparameter flow cytometric data, e.g. in the problem of human stem cell isolation with tumor purging. They also can provide training data for subsequent multivariate statistical classification techniques such as discriminant function or logistic regression analyses. Using lookup tables, these multivariate statistical calculations can be performed in real-time, and can even include probabilities of misclassification. Thus, the only distinction between off-line classification of cells in data analysis and real-time statistical decision-making for cell sorting is the time limit in which a classification decision must be made. For real-time cell sorting we presently are able to perform these classifications in less than 625 microseconds, corresponding to the time that it takes the cell to travel from the laser intersection point to the sort decision point in a flow cytometer/cell sorter. Statistical decision making and the ability to include the costs of misclassification into that decision process will become important as flow cytometry/cell sorting moves from diagnostics to therapeutics.

  8. 33 CFR 157.228 - Isolating Valves: Closed during a voyage.

    Science.gov (United States)

    2010-07-01

    ... SECURITY (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels Dedicated Clean Ballast Tanks Operations § 157.228 Isolating Valves: Closed during a voyage. (a) The master of each U.S. tank vessel under §...

  9. Isolation of proximity-induced triplet pairing channel in a superconductor/ferromagnet spin valve

    Science.gov (United States)

    Leksin, P. V.; Garif'yanov, N. N.; Kamashev, A. A.; Validov, A. A.; Fominov, Ya. V.; Schumann, J.; Kataev, V.; Thomas, J.; Büchner, B.; Garifullin, I. A.

    2016-03-01

    We have studied the proximity-induced superconducting triplet pairing in CoOx/Py1/Cu/Py2/Cu/Pb spin-valve structure (where Py = Ni0.81Fe0.19 ). By optimizing the parameters of this structure we found a triplet channel assisted full switching between the normal and superconducting states. To observe an "isolated" triplet spin-valve effect we exploited the oscillatory feature of the magnitude of the ordinary spin-valve effect Δ Tc in the dependence of the Py2-layer thickness dP y 2. We determined the value of dP y 2 at which Δ Tc caused by the ordinary spin-valve effect (the difference in the superconducting transition temperature Tc between the antiparallel and parallel mutual orientation of magnetizations of the Py1 and Py2 layers) is suppressed. For such a sample a "pure" triplet spin-valve effect which causes the minimum in Tc at the orthogonal configuration of magnetizations has been observed.

  10. Well purge and sample apparatus and method

    Science.gov (United States)

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.; Gustafson, Gregg S.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly with a packer, pump and exhaust, that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. The packer is positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  11. Anode purge strategy optimization of the polymer electrode membrane fuel cell system under the dead-end anode operation

    Science.gov (United States)

    Hu, Zhe; Yu, Yi; Wang, Guangjin; Chen, Xuesong; Chen, Pei; Chen, Jun; Zhou, Su

    2016-07-01

    Dead-ended anode (DEA) mode is commonly applied in fuel cell vehicles for the hydrogen purge at the anode side, to reduce fuel waste and enhance fuel cell efficiency. Anode purge is necessary and is definitely important with respect to removing liquid water and accumulated nitrogen in the gas diffusion layer and the flow field of the DEA-mode fuel cell. In this paper, the effect of different purge strategies on the stack performance and system efficiency is investigated experimentally using fast data acquisition and advanced tools, such as the fast cell voltage measurement (CVM) system and the mass spectrum. From the fast data acquisition, the voltage stability, liquid water and nitrogen concentration measurement in the anode exhaust are compared and analyzed under different purge strategy designs and using different purge valves. The results show that under the optimal purge strategy, the DEA fuel cell stack can achieve the desired stability and system efficiency based on the analysis of the cell voltage and purge volume. Moreover, the diameter of the purge valve has a great impact on the voltage stability because a diameter change will result in a different pressure drop and purge volume when the purge valve is open.

  12. TO PURGE OR NOT TO PURGE? VOC CONCENTRATION ...

    Science.gov (United States)

    Soil vapor surveys are commonly used as a screening technique to delineate volatile organic compound (VOC) contaminant plumes and provide information for soil sampling plans. Traditionally, three purge volumes of vapor are removed before a sample is collected. One facet of this study was to evaluate the VOC concentrations lost during purging and explore the potential implications of those losses. The vapor data was compared to collocated soil data to determine if any correlation existed between the VOC concentrations. Two different methods for soil vapor collection were compared: 1) active/micro-volume; and 2) active/macro-volume. The active/micro-volume vapor sample had total line purge volume of 1.25 mL and the active/macro-volume vapor sample had a total line purge volume of 15 mL. Six line purge volumes were collected for each vapor sampling technique, with the fourth purge volume representing the traditional sample used for site screening data. Each sample was collected by gas tight syringe and transferred to a thermal de sorption tube for sorption, transport, and analysis. Following the removal of the soil vapor samples, collocated soil samples were taken. For both active vapor sampling techniques, the VOC concentrations in the first three purge volumes exceeded the VOC concentrations in the last three purge volumes. This implies that the general rule of removal of three purge volumes prior to taking a sample for analysis could lead to underestimating the

  13. Legionella cardiaca sp. nov., isolated from a case of native valve endocarditis in a human heart.

    Science.gov (United States)

    Pearce, Meghan M; Theodoropoulos, Nicole; Mandel, Mark J; Brown, Ellen; Reed, Kurt D; Cianciotto, Nicholas P

    2012-12-01

    A Gram-negative, rod-shaped bacterium, designated H63(T), was isolated from aortic valve tissue of a patient with native valve endocarditis. 16S rRNA gene sequencing revealed that H63(T) belongs to the genus Legionella, with its closest neighbours being the type strains of Legionella brunensis (98.8% similarity), L. londiniensis (97.0%), L. jordanis (96.8%), L. erythra (96.2%), L. dresdenensis (96.0%) and L. rubrilucens, L. feeleii, L. pneumophila and L. birminghamensis (95.7%). DNA-DNA hybridization studies yielded values of cardiaca sp. nov. is proposed. The type strain is H63(T) ( = ATCC BAA-2315(T)  = DSM 25049(T)  = JCM 17854(T)).

  14. Isolated parachute mitral valve in a 29 years old female; a case report

    Directory of Open Access Journals (Sweden)

    Mehrnoush Toufan

    2016-03-01

    Full Text Available A 29-year old female patient was referred to our hospital for evaluation of dyspnea NYHA class I which begun from several months ago. The only abnormal sign found on physical examination was a grade 2/6 systolic murmur at the apex position without radiation. Echocardiography revealed normal left and right ventricular sizes and systolic function, and only one papillary muscle in left ventricular (LV cavity which all chordae tendineae inserted into that muscle. The mitral valve orifice was eccentrically located at the lateral side with mild to moderate mitral regurgitation but without significant mitral stenosis. No other congenital heart anomalies were identified. Thus, the final diagnosis was isolated parachute mitral valve (IPMV. She was one of the very rare IPMV cases have ever been reported in adults

  15. [Isolated Pulmonary Valve Endocarditis in a Patient with Aortic Regurgitation and Patent Foramen Ovale;Report of a Case].

    Science.gov (United States)

    Doi, Toshio; Gyoten, Takayuki; Sakata, Kimimasa; Nagura, Saori; Yamashita, Akio; Fukahara, Kazuaki; Kotoh, Keiju; Yoshimura, Naoki

    2016-07-01

    Isolated pulmonary valve endocarditis is an extremely rare clinical condition. Here, we report a case of pulmonary valve endocarditis caused by methicillin-resistant Staphylococcus aureus (MRSA). An 84-year-old man with a history of aortic regurgitation and patent foramen ovale was admitted to our hospital due to fever of unknown origin for 4 weeks' duration. MRSA was detected in his blood cultures. Transthoracic echocardiography demonstrated a mobile vegetation attached to the pulmonary valve, moderate to severe aortic regurgitation, and patent foramen ovale with left-to-right shunt. After 30-days' treatment with vancomycin, gentamicin and rifampicin, he defervesced and blood cultures became negative. At surgery, a large vegetation was still attached to the pulmonary valve, but the leaflets remained with minimum damage. Aortic valve replacement, direct closure of the patent foramen ovale, and simple resection of the vegetation were performed. The postoperative course was uneventful.

  16. Dynamic simulation of accidental closure of intermediate heat exchanger isolation valve in a pool type LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K., E-mail: natesan@igcar.gov.in [Reactor Engineering Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Kasinathan, N.; Velusamy, K.; Selvaraj, P.; Chellapandi, P.; Chetal, S.C. [Reactor Engineering Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2011-04-15

    Research highlights: > Thermal hydraulic analysis closure of sleeve valve in the primary circuit of FBR is discussed. > Numerical modeling of hydraulics in the primary and secondary sodium circuits is presented. > Aspects related to event management are discussed. - Abstract: In a pool type liquid metal cooled fast breeder reactor (LMFBR), core and other internals such as pumps, heat exchangers are immersed in a pool of sodium. Heat exchange from primary sodium circuit (pool) to secondary sodium circuit (loop) is through four intermediate heat exchangers (IHX) immersed in primary sodium pool. Each IHX is provided with a sleeve valve at its primary sodium inlet window for the purpose of isolating the shell side of IHX from the sodium pool. With such a provision, an inadvertent partial or complete closure of a sleeve valve of one of the IHX during normal operation of the reactor has been considered as a design basis event for the reactor. One dimensional transient thermal hydraulic models of the primary and secondary sodium circuits have been developed to study the thermal hydraulic consequences of such an event. The main areas of concern in the plant and the availability of safety parameters for the detection of the event have been evaluated.

  17. Isolated spontaneous dissection of the celiac trunk in a patient with bicuspid aortic valve

    Directory of Open Access Journals (Sweden)

    Abdel-Rauf Zeina

    2010-05-01

    Full Text Available Abdel-Rauf Zeina1, Alicia Nachtigal1, Anton Troitsa2, Gil Admon2, Nina Avshovich31Department of Radiology, 2Department of Surgery A, 3Department of Internal Medicine C, Hillel Yaffe Medical Center, Hadera, Israel. Hillel Yaffe Medical Center is affiliated with the Faculty of Medicine, Technion – Israel Institute of Technology, Haifa, IsraelAbstract: Isolated spontaneous dissection of celiac trunk is a rare entity. The spontaneous dissection of the visceral artery occurs without aortic dissection. The most consistent presenting symptom is acute onset abdominal pain. Complications consist of ischemia, aneurysm formation, and rupture. We report an exceptional case of an isolated spontaneous dissection of the celiac trunk which occurred in a 49 year old male with a previously undiagnosed bicuspid aortic valve (BAV. We also describe the classical appearance in different imaging modalities with a particular emphasis on multidetector computed tomography, and discuss the clinical manifestation and its relationship to BAV.Keywords: celiac trunk dissection, isolated spontaneous dissection, CT angiography, bicuspid aortic valve, MRA

  18. Cell pairing ratio controlled micro-environment with valve-less electrolytic isolation

    KAUST Repository

    Chen, Yu-Chih

    2012-01-01

    We present a ratio controlled cell-to-cell interaction chip using valve-less isolation. We incorporated electrolysis in a microfluidic channel. In each microfluidic chamber, we loaded two types of different cells at various pairing ratios. More than 80% of the microchambers were successfully loaded with a specific target pairing ratio. For the proof of concept, we have demonstrated the cell-to-cell interaction between prostate cancer cells and muscle stem cells can be controlled by cell pairing ratios through growth factor secretion. The experimental data shows that sealing of microenvironment by air generated from electrolysis does not affect cell viability and cell interaction assay results. © 2012 IEEE.

  19. ZAP: Zurich Atmosphere Purge

    Science.gov (United States)

    Soto, Kurt T.; Lilly, Simon J.; Bacon, Roland; Richard, Johan; Conseil, Simon

    2016-02-01

    ZAP (Zurich Atmosphere Purge) provides sky subtraction for integral field spectroscopy; its approach is based on principal component analysis (PCA) developed for the Multi Unit Spectrographic Explorer (MUSE) integral field spectrograph. ZAP employs filtering and data segmentation to enhance the inherent capabilities of PCA for sky subtraction. ZAP reduces sky emission residuals while robustly preserving the flux and line shapes of astronomical sources; this method works in a variety of observational situations from sparse fields with a low density of sources to filled fields in which the target source fills the field of view. With the inclusion of both of these situations the method is generally applicable to many different science cases and should also be useful for other instrumentation.

  20. Exploration EVA Purge Flow Assessment

    Science.gov (United States)

    Navarro, Moses; Conger, Bruce; Campbell, Colin

    2011-01-01

    An advanced future spacesuit will require properly sized suit and helmet purge flow rates in order to sustain a crew member with a failed Portable Life Support System (PLSS) during an Extravehicular Activity (EVA). A computational fluid dynamics evaluation was performed to estimate the helmet purge flow rate required to washout carbon dioxide and to prevent the condensing ("fogging") of water vapor on the helmet visor. An additional investigation predicted the suit purge flow rate required to provide sufficient convective cooling to keep the crew member comfortable. This paper summarizes the results of these evaluations.

  1. Thermal vacuum chamber repressurization with instrument purging

    Science.gov (United States)

    Woronowicz, Michael S.

    2016-09-01

    At the conclusion of cryogenic vacuum testing of the James Webb Space Telescope Optical Telescope Element Integrated Science Instrument Module (JWST-OTIS) in NASA Johnson Space Center's (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are postulating that chamber particulate material stirred up by the repressurization process may be kept from falling into the Integrated Science Instrument Module (ISIM) interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This manuscript describes development of a series of models designed to describe this process. The models are strung together in tandem with a fictitious set of conditions to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  2. Thermal Vacuum Chamber Repressurization with Instrument Purging

    Science.gov (United States)

    Woronowicz, Michael

    2017-01-01

    At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

  3. Isolated Pulmonary Valve Endocarditis Complicated With Septic Emboli to the Lung Causing Pneumothorax, Pneumonia, and Sepsis in an Intravenous Drug Abuser

    Directory of Open Access Journals (Sweden)

    Deephak Swaminath MD

    2013-11-01

    Full Text Available Intravenous drug users are at increased risk for developing right-sided infective endocarditis involving the tricuspid and pulmonary valves. Isolated pulmonary valve endocarditis in intravenous drug users is very rare, and these patients often have more complications, such as pulmonary embolism, sepsis, and pneumonia. We report a case with pulmonary valve endocarditis and extensive pulmonary complications, including sepsis, septic emboli, pneumonia, and pneumothorax. Early identification of pulmonic valve endocarditis and treatment with appropriate antibiotics with or without surgical management should provide better outcomes, and clinicians need to think about pulmonary valve endocarditis in patients with complex respiratory presentations.

  4. [Isolated agenesis of the pulmonary valve in the adult. When is the proper time for surgery?].

    Science.gov (United States)

    Rangel-Abundis, A; Chávez-Pérez, E; Badui, E; García, P; Enciso, R; Sánchez Moreira, L M; Zamora, C; Marín, G

    1993-01-01

    The congenital absence of the pulmonary valves is a rare malformation that mainly affects children, frequently is associated with other cardiac malformations and very rarely is present in adults. Elective or urgent surgery is indicated in the symptomatic child; on the other hand, surgical treatment in the asymptomatic adult with this anomaly is controversial. Based on the reported experience in the literature, in the present article, the authors discuss the therapeutic approach of an asymptomatic 22-year-old male with pulmonary valvular absence with practically no hemodynamic repercussion. Although there had been few reported cases of isolated pulmonary valvular absence, the authors concluded that surgery is not a satisfactory solution and that it might be postponed to the time that patients develop congestive heart failure and or respiratory insufficiency. In order to detect that on time, we recommend a follow up based on periodic echocardiographic studies.

  5. Cyclically controlled welding purge chamber

    Science.gov (United States)

    Gallagher, Robert L. (Inventor)

    1996-01-01

    An arrangement for butt-welding cylindrical sections of large, thin-wall tanks includes a rotatable mandrel with side-by-side sets of radial position adjusters. Each set of adjusters bears on one of the tank sections adjacent the seam, to prevent the sections from sagging out-of-round. The mandrel rotates relative to the welder, so that a continuous seam is formed. A purge chamber is fixed in position behind the seam at the weld head, and is flushed with inert gas. The purge chamber includes a two-sided structure which is contiguous with the cylindrical sections and a circumferential vane to form an open-ended tube-like structure, through which the radial position adjusters pass as the mandrel and cylindrical workpiece sections rotate. The tube-like structure is formed into a chamber by a plurality of movable gates which are controlled to maintain a seal while allowing adjusters to progress through the purge chamber.

  6. Repair or Replacement for Isolated Tricuspid Valve Pathology? Insights from a Surgical Analysis on Long-Term Survival

    Science.gov (United States)

    Farag, Mina; Arif, Rawa; Sabashnikov, Anton; Zeriouh, Mohamed; Popov, Aron-Frederik; Ruhparwar, Arjang; Schmack, Bastian; Dohmen, Pascal M.; Szabó, Gábor; Karck, Matthias; Weymann, Alexander

    2017-01-01

    Background Long-term follow-up data concerning isolated tricuspid valve pathology after replacement or reconstruction is limited. Current American Heart Association guidelines equally recommend repair and replacement when surgical intervention is indicated. Our aim was to investigate and compare operative mortality and long-term survival in patients undergoing isolated tricuspid valve repair surgery versus replacement. Material/Methods Between 1995 and 2011, 109 consecutive patients underwent surgical correction of tricuspid valve pathology at our institution for varying structural pathologies. A total of 41 (37.6%) patients underwent tricuspid annuloplasty/repair (TAP) with or without ring implantation, while 68 (62.3%) patients received tricuspid valve replacement (TVR) of whom 36 (53%) were mechanical and 32 (47%) were biological prostheses. Results Early survival at 30 days after surgery was 97.6% in the TAP group and 91.1% in the TVR group. After 6 months, 89.1% in the TAP group and 87.8% in the TVR group were alive. In terms of long-term survival, there was no further mortality observed after one year post surgery in both groups (Log Rank p=0.919, Breslow p=0.834, Tarone-Ware p=0.880) in the Kaplan-Meier Survival analysis. The 1-, 5-, and 8-year survival rates were 85.8% for TAP and 87.8% for TVR group. Conclusions Surgical repair of the tricuspid valve does not show survival benefit when compared to replacement. Hence valve replacement should be considered generously in patients with reasonable suspicion that regurgitation after repair will reoccur. PMID:28236633

  7. Electrolytic valving isolation of cell co-culture microenvironment with controlled cell pairing ratios.

    Science.gov (United States)

    Chen, Yu-Chih; Ingram, Patrick; Yoon, Euisik

    2014-12-21

    Cancer-stromal interaction is a critical process in tumorigenesis. Conventional dish-based co-culture assays simply mix two cell types in the same dish; thus, they are deficient in controlling cell locations and precisely tracking single cell behavior from heterogeneous cell populations. Microfluidic technology can provide a good spatial-temporal control of microenvironments, but the control has been typically realized by using external pumps, making long-term cultures cumbersome and bulky. In this work, we have presented a cell-cell interaction microfluidic platform that can accurately control the co-culture microenvironment by using a novel electrolytic cell isolation scheme without using any valves or pneumatic pumps. The proposed microfluidic platform can also precisely control the number of interacting cells and pairing ratios to emulate cancer niches. More than 80% of the chambers captured the desired number of cells. The duration of cell isolation can be adjusted by electrolytic bubble generation and removal. We have verified that the electrolytic process has a negligible effect on cell viability and proliferation in our platform. To the best of our knowledge, this work is the first attempt to incorporate electrolytic bubble generation as a cell isolation method in microfluidics. For proof of feasibility, we have performed cell-cell interaction assays between prostate cancer (PC3) cells and myoblast (C2C12) cells. The preliminary results demonstrated the potential of using electrolysis for micro-environmental control during cell culture. Also, the ratio controlled cell-cell interaction assays were successfully performed which showed that the cell pairing ratios of PC3 to C2C12 affected the proliferation rate of myoblast cells due to increased secretion of growth factors from prostate cancer cells.

  8. Predicted Risk of Mortality, Transfusion, and Postoperative Outcomes in Isolated Primary Valve Operations.

    Science.gov (United States)

    Keeling, W Brent; Binongo, Jose; Sarin, Eric L; Leshnower, Bradley G; Chen, Edward P; Lattouf, Omar M; Thourani, Vinod H; Guyton, Robert A; Halkos, Michael E

    2016-02-01

    Transfusion has been linked with increased postoperative morbidity and death after cardiac operations. The purpose of this study was to determine the associations among The Society of Thoracic Surgeons Predicted Risk of Mortality (PROM), transfusion, and postoperative outcomes in patients who underwent isolated primary valve operations. A retrospective review of the local Society of Thoracic Surgeons database of 1,575 adults undergoing isolated primary valve operations from 2003 to 2013 at a United States academic center was performed. Patients were compared by their postoperative transfusion status (NONE vs TRANS) and by PROM. Taking into account procedure type and preoperative hemoglobin, three-step multiple linear or logistic regression analyses were performed to assess (1) the influence of PROM on postoperative outcomes, (2) influence of PROM on transfusion, and (3) influence of PROM and transfusion on postoperative outcomes. Of 1,575 patients studied, 1,245 (79%) received transfusions. The mean PROM was 1.2% (95% confidence interval [CI], 1.1 to 1.3) for patients in the NONE group, and was 2.7% (95% CI, 2.6 to 2.9) for the TRANS group. The correlation between PROM and total red blood cell units transfused was r = 0.31 (p < 0.0001). Patients with a PROM of 4% to 8% (odds ratio [OR], 2.10; 95% CI, 1.28 to 3.45) and exceeding 8% (OR 3.80, 95% CI, 1.35 to 10.68) were more likely to receive transfusions than the low-risk (<4%) PROM stratum. For each percentage increase in PROM, the odds of transfusion increased by 27% (95% CI, 16% to 39%), controlling for procedure type and preoperative hemoglobin. There were no 30-day deaths in the NONE group, and rates of stroke, renal failure, and mediastinitis were lower. Composite event rates increased with increasing PROM (OR, 1.39; 95% CI, 1.19 to 1.63), with TRANS patients consistently showing a higher risk of major adverse cardiac events than NONE patients (OR, 7.47; 95% CI, 2.08 to 26.80). Increased PROM yielded higher

  9. Quadricuspid Aortic Valve

    Directory of Open Access Journals (Sweden)

    Mehmet Taşar

    2013-03-01

    Full Text Available Quadricuspid aortic valve is an extremely rare congenital defect. Isolated form appears frequently. It is seen with aortic valve regurgitation in adulthood. This case report presents a rare clinical finding of an isolated quadricuspid aortic valve with aortic regurgitation in an 64-year-old female who was referred for cardiac evaluation due to newly identified murmur.

  10. 49 CFR 193.2517 - Purging.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Purging. 193.2517 Section 193.2517 Transportation...: FEDERAL SAFETY STANDARDS Operations § 193.2517 Purging. When necessary for safety, components that could accumulate significant amounts of combustible mixtures must be purged in accordance with a procedure...

  11. Cardiopulmonary manifestations of isolated pulmonary valve infective endocarditis demonstrated with cardiac CT.

    Science.gov (United States)

    Passen, Edward; Feng, Zekun

    2015-01-01

    Right-sided infective endocarditis involving the pulmonary valve is rare. This pictorial essay discusses the use and findings of cardiac CT combined with delayed chest CT and noncontrast chest CT of pulmonary valve endocarditis. Cardiac CT is able to show the full spectrum of right-sided endocarditis cardiopulmonary features including manifestations that cannot be demonstrated by echocardiography.

  12. Reliability of Modern Scores to Predict Long-Term Mortality After Isolated Aortic Valve Operations.

    Science.gov (United States)

    Barili, Fabio; Pacini, Davide; D'Ovidio, Mariangela; Ventura, Martina; Alamanni, Francesco; Di Bartolomeo, Roberto; Grossi, Claudio; Davoli, Marina; Fusco, Danilo; Perucci, Carlo; Parolari, Alessandro

    2016-02-01

    Contemporary scores for estimating perioperative death have been proposed to also predict also long-term death. The aim of the study was to evaluate the performance of the updated European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons Predicted Risk of Mortality score, and the Age, Creatinine, Left Ventricular Ejection Fraction score for predicting long-term mortality in a contemporary cohort of isolated aortic valve replacement (AVR). We also sought to develop for each score a simple algorithm based on predicted perioperative risk to predict long-term survival. Complete data on 1,444 patients who underwent isolated AVR in a 7-year period were retrieved from three prospective institutional databases and linked with the Italian Tax Register Information System. Data were evaluated with performance analyses and time-to-event semiparametric regression. Survival was 83.0% ± 1.1% at 5 years and 67.8 ± 1.9% at 8 years. Discrimination and calibration of all three scores both worsened for prediction of death at 1 year and 5 years. Nonetheless, a significant relationship was found between long-term survival and quartiles of scores (p < 0.0001). The estimated perioperative risk by each model was used to develop an algorithm to predict long-term death. The hazard ratios for death were 1.1 (95% confidence interval, 1.07 to 1.12) for European System for Cardiac Operative Risk Evaluation II, 1.34 (95% CI, 1.28 to 1.40) for the Society of Thoracic Surgeons score, and 1.08 (95% CI, 1.06 to 1.10) for the Age, Creatinine, Left Ventricular Ejection Fraction score. The predicted risk generated by European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons score, and Age, Creatinine, Left Ventricular Ejection Fraction scores cannot also be considered a direct estimate of the long-term risk for death. Nonetheless, the three scores can be used to derive an estimate of long-term risk of death in patients who undergo

  13. Spectrum of cardiac lesions associated with Isolated Cleft Mitral Valve and their impact on therapeutic choices

    Science.gov (United States)

    El hammiri, Ayoub; Drighil, Abdenasser; Benhaourech, Sanaa

    2016-01-01

    Background Isolated cleft mitral valve (ICMV) may occur alone or in association with other congenital heart lesions. The aim of this study was to describe the profile of cardiac lesions associated with ICMV and their potential impact on therapeutic management. Methods We conducted a descriptive study with data retrieved from the Congenital Heart Disease (CHD) single-center registry of our institution, including patients with ICMV registered between December 2008 and November 2014. Results Among 2177 patients retrieved from the CHD registry, 22 (1%) had ICMV. Median age at diagnosis was 5 years (6 days to 36 years). Nine patients (40.9%) had Down syndrome. Seventeen patients (77.3%) had associated lesions, including 11 (64.7%) with accessory chordae in the left ventricular outflow tract (LVOT) with no obstruction, 15 (88.2%) had ventricular septal defect (VSD), three had secundum atrial septal defect, and four had patent ductus arteriosus. Thirteen patients (59.1%) required surgical repair. The decision to proceed with surgery was mainly based on the severity of the associated lesion in eight patients (61.5%) and on the severity of the mitral regurgitation in four patients (30.8%). In one patient, surgery was decided based on the severity of both the associated lesion and mitral regurgitation. Conclusion Our study shows that ICMV is rare and strongly associated with Down syndrome. The most common associated cardiac abnormalities were VSD and accessory chordae in the LVOT. We conclude that cardiac lesions associated with ICMV are of major interest, since in this study patients with cardiac lesions were diagnosed earlier. The decision to operate on these patients must take into account the severity of both mitral regurgitation and associated cardiac lesions. PMID:27096525

  14. On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve.

    Science.gov (United States)

    Kohl, Felix J; Montealegre, Cristina; Neusüß, Christian

    2016-04-01

    CE is becoming more and more important in many fields of bioanalytical chemistry. Besides optical detection, hyphenation to ESI-MS detection is increasingly applied for sensitive identification purposes. Unfortunately, many CE techniques and methods established in research and industry are not compatible to ESI-MS since essential components of the background electrolyte interfere in ES ionization. In order to identify unknown peaks in established CE methods, here, a heart-cut 2D-CE separation system is introduced using a fully isolated mechanical valve with an internal loop of only 20 nL. In this system, the sample is separated using potentially any non-ESI compatible method in the first separation dimension. Subsequently, the portion of interest is cut by the internal sample loop of the valve and reintroduced to the second dimension where the interfering compounds are removed, followed by ESI-MS detection. When comparing the separation efficiency of the system with the valve to a system using a continuous capillary only a slight increase in peak width is observed. Ultraviolet/visible detection is integrated in the first dimension for switching time determination, enabling reproducible cutting of peaks of interest. The feasibility of the system is successfully demonstrated by a 2D analysis of a BSA tryptic digest sample using a nonvolatile (phosphate based) background electrolyte in the first dimension.

  15. Purge water minimization at LEHR

    Energy Technology Data Exchange (ETDEWEB)

    Schalla, R.

    1996-11-01

    The field demonstration described in this report is being conducted as part of the Environmental Restoration Program at the Laboratory for Energy-Related Health Research (LEHR). The Environmental Restoration Program is one of several U.S. Department of Energy (DOE) waste cleanup projects designed to support by the actual use of emerging environmental management and restoration technologies. As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at LEHR, DOE requested Pacific Northwest National Laboratory`s (PNNL`s) guidance to identify the most efficient way of reducing purge water extracted by sampling pumps while still obtaining representative samples from LEHR monitoring wells.

  16. Leak testing in isolation in Almaraz NPP valves; Pruebas de fugas en valvulas de aislamiento en C.N. Almaraz

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Rocasolano, J.; Delgado Flores, E.

    2014-07-01

    The components, object of this paper are isolation valves of the containment of waste heat, injection safety and water extraction systems of sealing of the main pumps. A review and improvement of the methodology applied by means of an analysis of the provision and operation of certain systems, as well as practice followed by other plants in the US, aims to achieve a more effective testing program by reducing doses to staff, the generation of radioactive waste by drainage systems, and the risks of introduction of parts loose in the primary. (Author)

  17. Valve Disease

    Science.gov (United States)

    ... heart valves, valve insufficiency, valve regurgitation, valve stenosis, valvular heart disease Every time your heart beats, blood flows into, ... removed from the market after being linked to heart valve disease. An infection in the lining of the heart's ...

  18. The Medical Complications Associated with Purging

    Science.gov (United States)

    Forney, K. Jean; Buchman-Schmitt, Jennifer M.; Keel, Pamela K.; Frank, Guido K.W.

    2015-01-01

    Objective Purging behaviors, including self-induced vomiting, laxative abuse, and diuretic abuse, are present across many of the eating disorders. Here we review the major medical complications of these behaviors. Method Although we identified over 100 scholarly articles describing medical complications associated with purging, most papers involved case studies or small, uncontrolled samples. Given the limited evidence base, we conducted a qualitative (rather than systematic) review to identify medical complications that have been attributed to purging behaviors. Results Medical conditions affecting the teeth, esophagus, gastrointestinal system, kidneys, skin, cardiovascular system, and musculoskeletal system were identified, with self-induced vomiting causing the most medical complications. Conclusions Purging behavior can be associated with severe medical complications across all body systems. Mental health professionals should refer patients with purging behaviors to medical providers for screening and treatment as needed. The medical work-up for individuals with eating disorders should include a comprehensive metabolic panel, complete blood count, and a full body exam including the teeth to prevent severe complications. Medical providers should screen patients for purging behaviors and associated medical complications, even in the absence of an eating disorder diagnosis, to increase the detection of eating disorders. Recognizing the link between purging and medical complications can aid in identifying potential eating disorders, particularly those that often elude detection such as purging disorder. PMID:26876429

  19. Selective purge for hydrogenation reactor recycle loop

    Science.gov (United States)

    Baker, Richard W.; Lokhandwala, Kaaeid A.

    2001-01-01

    Processes and apparatus for providing improved contaminant removal and hydrogen recovery in hydrogenation reactors, particularly in refineries and petrochemical plants. The improved contaminant removal is achieved by selective purging, by passing gases in the hydrogenation reactor recycle loop or purge stream across membranes selective in favor of the contaminant over hydrogen.

  20. Whitey Gauge and Root Valves (VPS)

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel: Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the Vacuum Pumping and Helium System.

  1. Taps/valves in extreme conditions. Choice for tap-actuator sets for refining and petrochemical operations in severe conditions. Main steam isolation valves in extremely severe conditions. Presentation of the SRV (Safety Relief Valve) development; Robinets vannes en conditions extremes. Choix d`ensembles robinets-operateurs pour des operations en conditions severes dans le raffinage et la petrochimie. Vannes d`isolement vapeur principales en conditions tres severes. Presentation du developpement de la vanne SRV (safety relief valve)

    Energy Technology Data Exchange (ETDEWEB)

    Brunet, X.F.; Aubry, F. [Institut Francais du Petrole, 92 - Rueil-Malmaison (France); Guesnon, D. [Technicatome Cadarache, 13 - Saint-Paul-Lez-Durance (France); Martin, R. [Vanatome, 07 - Annonay (France); Mainguette, Ph. [Adareg (France)

    1998-05-01

    This series of 3 papers was presented during a workshop organized by the French Society of mechanical engineers in 1997. The aim of the workshop was to take stock of the most recent developments in the domain of taps and valves devoted to extreme condition uses (very high or very low temperatures or pressures and corrosive ambiences). The first paper deals with selection criteria for the choice of valve-actuator sets devoted to high temperature liquid aromatic fluids in the refining and petrochemical industries (technical specifications, selection, qualification tests, quality control and tests feedback). The second paper presents the global conceiving process which led to adapt a general concept of valve to a specific application to propulsion reactors of nuclear ships: the steam isolation valves (technical specifications, particular constraints, prototype and serial product, maintenance and experience feedback). The third paper concerns the development of a safety relief valve for the superfluid helium cooling system of the superconducting magnets of the future LHC (Large Hadron Collider) of the CERN (technical specifications, general characteristics, functioning principle, technology and conceiving, test of prototypes and results). (J.S.)

  2. Replacement of 13 valves by using an isolation plug in the 20 inches diameter main offshore gas pipeline at Cantarell oil field, Campeche Bay, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Carvahal Reyes, Jorge Omar; Ulloa Ochoa, Carlos Manuel [PEMEX, Exploracion y Produccion, MX (Mexico)

    2009-12-19

    In 2002 we changed 13 valves on deck of one gas production platform called Nohoch-A-Enlace at Cantarell Offshore Oil Field. The 20'' diameter gas pipeline and 200 km of length, transport and deliver gas for others production platforms in the Gas Lift System, So 2 millions of oil barrels per day depends of the operation of this gas pipeline but there was 13 valves on pig traps to be changed after 20 years of service to high pressure (64 to 63 kg/cm{sup 2}). We could not stop the operation of this pipeline and some little gas leaks were eliminated in some parts of the valves. This pipeline has two risers so the gas can be injected by two sides of the ring of 20 Km. So we found the proper technology in order to isolate one riser nad change 8 valves and the isolate the other and change the 5, and the gas lift system never stop during the plug and maintenance operations on platform. In the first isolation plug operation this tool run 20 mts inside the riser and was actionated and resists 65 Kg/cm{sup 2} of gas pressure during 44 hours so we changed 8 valves: 2 of 20'', 2 of 10'', 3 of 4'' and 1 of 8'' diameter. In the second isolation the plug run 30 mts inside the second risers and resist 64 Kg/cm{sup 2} of gas during 46 hours and we changed 5 valves of 20'' diameter. In the paper I will describe all the details of this successful operations and procedures. Also the aspects of Health, Security and Environment that we prepared one year before this operations at platform. Pemex save almost 2.5 millions of dollars because the gas lift system never stop and all valves were changed and now we can run cleaning and inspection tools inside the full ring. We used the first isolation plug in Latin America and we want to share this experience to all the pipeline operators in the world as a good practice in pipeline maintenance using plugging technology in the main and large pipelines of high pressure. (author)

  3. ''Isolation'' of the proximity-induced triplet pairing channel in the superconductor/ferromagnet spin valve

    Energy Technology Data Exchange (ETDEWEB)

    Leksin, Pavel [Leibniz Institute for Solid State and Materials Research Dresden, IFW Dresden (Germany); Zavoisky Physical-Technical Institute, Russian Academy of Sciences, Kazan (Russian Federation); Garifyanov, Nadir; Kamashev, Andrey; Validov, Aidar; Garifullin, Ilgiz [Zavoisky Physical-Technical Institute, Russian Academy of Sciences, Kazan (Russian Federation); Fominov, Yakov [L.D. Landau Institute for Theoretical Physics, Russian Academy of Sciences, Chernogolovka (Russian Federation); Moscow Institute of Physics and Technology, Dolgoprudny (Russian Federation); Schumann, Joachim; Kataev, Vladislav; Thomas, Juergen [Leibniz Institute for Solid State and Materials Research Dresden, IFW Dresden (Germany); Buechner, Bernd [Leibniz Institute for Solid State and Materials Research Dresden, IFW Dresden (Germany); Institute for Solid State Physics, Technical University Dresden (Germany)

    2016-07-01

    We have studied the proximity induced superconducting triplet pairing in CoO{sub x}/Py1/Cu/Py2/Cu/Pb spin-valve structure. By optimizing the parameters of structures we found a full switching between the normal and superconducting states. To observe an ''isolated'' triplet spin-valve effect we exploited the oscillatory feature of the magnitude of the ordinary spin-valve effect ΔT{sub c} in the dependence of the Py2-layer thickness d{sub Py2}. We determined the value of d{sub Py2} at which ΔT{sub c} caused by the ordinary spin-valve effect (the difference in T{sub c} between antiparallel and parallel mutual orientation of magnetizations of the Py1 and Py2 layers) is suppressed. For such a sample a ''pure'' triplet spin-valve effect which causes the minimum in T{sub c} at the orthogonal configuration of magnetizations has been observed.

  4. Performance of Gas Purge System of Absorption Refrigerating Machine

    Science.gov (United States)

    Kunugi, Yoshifumi; Ouchi, Tomihisa; Usui, Sanpei; Sugimoto, Shigeo

    Experimental studies on performance of two gas purge systems for the lithium bromide-water absorption refrigerating machine are presented in this paper. The first purge system is that the solution flow entrains the incondensable gas from the absorber in the first purge chamber, then the incondesable gas from the condenser in the second purge chamber. The second purge system is that the solution flow entrains the incondensable gas, separates it in the separator, and then returns to the refrigerating machine through the inverted U tube. As a result, purged gas rate of both gas purge systems conforms to the theoretical equation ; S=V0(P-P0), where S is purged gas rate, V0 is exhaust gas rate, P is pressure of purge chamber, and P0 is saturated vapor pressure of solution.

  5. Purge efficiency in the determination of trihalomethanes in water by purge-and-trap gas chromatography.

    Science.gov (United States)

    Ruiz-Bevia, Francisco; Fernandez-Torres, Maria J; Blasco-Alemany, Maria P

    2009-01-26

    Purge-and-trap gas chromatography-mass spectrometry (PT-GC-MS) has become an accepted method for the analysis of trihalomethanes (THMs) in water. The purge-and-trap technique is based on an efficient transfer of volatile organic compounds from the liquid (contained in the purge chamber) to the gaseous phase by bubbling with an inert gas. The aim of this work was to study the purge system's efficiency by means of several consecutive purge cycles lasting 11 min each of the same liquid sample. The concentration range chosen of THMs was very wide [5-200 microg L(-1)]. The inert gas flow rate was 40 mL min(-1), and experiments were performed at temperatures of 25, 35 and 50 degrees C. Bromoform (CHBr(3)), the least volatile compound, needed 19 cycles to be purged quantitatively at a concentration of 200 microg L(-1) and only 7 cycles at 5 microg L(-1) for a 25 mL sample at 25 degrees C. Chloroform (CHCl(3)), the most volatile compound, required 4 cycles to be fully extracted at 200 microg L(-1) and 2 at 5 microg L(-1). Finally, Novak's theoretical model, based on the distribution constant between gas and liquid phases, was used to correlate the THMs purging extraction data.

  6. Purging dissolved oxygen by nitrogen bubble aeration

    Science.gov (United States)

    Yamashita, Tatsuya; Ando, Keita

    2016-11-01

    We apply aeration with nitrogen microbubbles to water in order to see whether oxygen gas originally dissolved in the water at one atmosphere is purged by the aeration. The concentration of dissolved oxygen (DO) is detected by a commercial DO meter. To detect the dissolved nitrogen (DN) level, we observe the growth of millimetre-sized bubbles nucleated at glass surfaces in contact with the aerated water and compare it with the Epstein-Plesset theory that accounts for DO/DN diffusions and the presence of the glass surfaces. Comparisons between the experiment and the theory suggest that the DO in the water are effectively purged by the aeration.

  7. Direct measurements of nitric oxide release in relation to expression of endothelial nitric oxide synthase in isolated porcine mitral valves

    DEFF Research Database (Denmark)

    Moesgaard, Sophia Gry; Olsen, Lisbeth Høier; Aasted, Bent;

    2007-01-01

    The aim of this study was to measure the direct release of nitric oxide (NO) from the porcine mitral valve using a NO microelectrode. Furthermore, the expression and localization of endothelial nitric oxide synthase (eNOS) in the mitral valve was studied using immunohistochemistry, Western blotting...

  8. Argon purge gas cooled by chill box

    Science.gov (United States)

    Spiro, L. W.

    1966-01-01

    Cooling argon purge gas by routing it through a shop-fabricated chill box reduces charring of tungsten inert gas torch head components. The argon gas is in a cooled state as it enters the torch and prevents buildup of char caused by the high concentrations of heat in the weld area during welding operations.

  9. Usefulness of maximal oxygen pulse in timing of pulmonary valve replacement in patients with isolated pulmonary regurgitation.

    Science.gov (United States)

    Legendre, Antoine; Richard, Ruddy; Pontnau, Florence; Jais, Jean-Philippe; Dufour, Marc; Grenier, Olivier; Mousseaux, Elie; Ladouceur, Magalie; Iserin, Laurence; Bonnet, Damien

    2016-10-01

    Patients with pulmonary regurgitation after tetralogy of Fallot repair have impaired aerobic capacity; one of the reasons is the decreasing global ventricular performance at exercise, reflected by decreasing peak oxygen pulse. The aims of our study were to evaluate the impact of pulmonary valve replacement on peak oxygen pulse in a population with pure pulmonary regurgitation and with different degrees of right ventricular dilatation and to determine the predictors of peak oxygen pulse after pulmonary valve replacement. The mean and median age at pulmonary valve replacement was 27 years. Mean pre-procedural right ventricular end-diastolic volume was 182 ml/m2. Out of 24 patients, 15 had abnormal peak oxygen pulse before pulmonary valve replacement. We did not observe a significant increase in peak oxygen pulse after pulmonary valve replacement (p=0.76). Among cardiopulmonary test/MRI/historical pre-procedural parameters, peak oxygen pulse appeared to be the best predictor of peak oxygen pulse after pulmonary valve replacement (positive and negative predictive values, respectively, 0.94 and 1). After pulmonary valve replacement, peak oxygen pulse was well correlated with left ventricular stroke and end-diastolic volumes (r=0.67 and 0.68, respectively). Our study confirms the absence of an effect of pulmonary valve replacement on peak oxygen pulse whatever the initial right ventricular volume, reflecting possible irreversible right and/or left ventricle lesions. Pre-procedural peak oxygen pulse seemed to well predict post-procedural peak oxygen pulse. These results encourage discussions on pulmonary valve replacement in patients showing any decrease in peak oxygen pulse during their follow-up.

  10. Analysis of main steam isolation valve leakage in design basis accidents using MELCOR 1.8.6 and RADTRAD.

    Energy Technology Data Exchange (ETDEWEB)

    Salay, Michael (United States Nuclear Regulatory Commission, Washington, D.C.); Kalinich, Donald A.; Gauntt, Randall O.; Radel, Tracy E.

    2008-10-01

    Analyses were performed using MELCOR and RADTRAD to investigate main steam isolation valve (MSIV) leakage behavior under design basis accident (DBA) loss-of-coolant (LOCA) conditions that are presumed to have led to a significant core melt accident. Dose to the control room, site boundary and LPZ are examined using both approaches described in current regulatory guidelines as well as analyses based on best estimate source term and system response. At issue is the current practice of using containment airborne aerosol concentrations as a surrogate for the in-vessel aerosol concentration that exists in the near vicinity of the MSIVs. This study finds current practice using the AST-based containment aerosol concentrations for assessing MSIV leakage is non-conservative and conceptually in error. A methodology is proposed that scales the containment aerosol concentration to the expected vessel concentration in order to preserve the simplified use of the AST in assessing containment performance under assumed DBA conditions. This correction is required during the first two hours of the accident while the gap and early in-vessel source terms are present. It is general practice to assume that at {approx}2hrs, recovery actions to reflood the core will have been successful and that further core damage can be avoided. The analyses performed in this study determine that, after two hours, assuming vessel reflooding has taken place, the containment aerosol concentration can then conservatively be used as the effective source to the leaking MSIV's. Recommendations are provided concerning typical aerosol removal coefficients that can be used in the RADTRAD code to predict source attenuation in the steam lines, and on robust methods of predicting MSIV leakage flows based on measured MSIV leakage performance.

  11. Exercise capacity and ventricular function in patients treated for isolated pulmonary valve stenosis or tetralogy of Fallot.

    Science.gov (United States)

    Luijnenburg, Saskia E; de Koning, Wilfred B; Romeih, Soha; van den Berg, Jochem; Vliegen, Hubert W; Mulder, Barbara J M; Helbing, Willem A

    2012-07-26

    We hypothesized 1) that long-term ventricular outcome and exercise capacity would be better in patients with isolated pulmonary valve stenosis (PS) treated with balloon pulmonary valvuloplasty (BPV) than in patients operated for tetralogy of Fallot (TOF), and 2) that ventricular outcome and exercise capacity would not be different in PS patients and healthy controls. We included 21 PS patients after BPV (16.2 ± 5.2 years) and 21 patients operated for TOF (16.6 ± 5.6 years), matching them for gender, age at treatment, and age at study. Patients underwent cardiovascular magnetic resonance (CMR) imaging, exercise testing, 12-lead ECG and 24-hour Holter monitoring for assessment of right ventricular (RV) size and function, pulmonary regurgitation (PR), exercise capacity and electrocardiographic status. Healthy controls for CMR imaging and exercise testing were matched for gender and age at study. RV volumes and PR percentage were significantly larger in TOF patients than in PS patients; biventricular ejection fraction (EF) was not different. PR was mild in most PS patients. RV end-systolic volume was significantly larger in PS patients than in healthy controls; RVEF was significantly lower. Both patient groups had similar exercise test results. Peak workload and VO(2) max. were significantly lower in PS patients than in healthy controls. Longstanding mild PR in PS patients can lead to an enlarged RV, reduced RV function and reduced exercise capacity. Despite more PR and larger RV volumes in TOF patients, exercise capacity and biventricular function are similar in both patient groups. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. The impact of age and severity of comorbid illness on outcomes after isolated aortic valve replacement for aortic stenosis

    Directory of Open Access Journals (Sweden)

    Russo MJ

    2015-05-01

    Full Text Available Mark J Russo,1,2 Alexander Iribarne,3 Emily Chen,2 Ashwin Karanam,2 Chris Pettit,2 Fabio Barili,4 Atman P Shah,5 Craig R Saunders1,2 1Barnabas Health Hospital, Newark/Livingston, NJ, USA; 2Barnabas Health Cardiovascular Clinical Research Center, Newark, NJ, USA; 3Duke University, Durham, NC, USA; 4Department of Cardiovascular Surgery, S Croce Hospital, Cuneo, Italy; 5University of Chicago, Chicago, IL, USA Objectives: This study examines outcomes in a national sample of patients undergoing isolated aortic valve replacement (AVR for aortic stenosis, with particular focus on advanced-age patients and those with extreme severity of comorbid illness (SOI. Methods: Data were obtained from the Nationwide Inpatient Sample and included all patients undergoing AVRs performed from January 1, 2006 to December 31, 2008. Patients with major concomitant cardiac procedures, as well as those aged <20 years, and those with infective endocarditis or aortic insufficiency without aortic stenosis, were excluded from analysis. The analysis included 13,497 patients. Patients were stratified by age and further stratified by All Patient Refined Diagnosis Related Group SOI into mild/moderate, major, and extreme subgroups. Results: Overall in-hospital mortality was 2.96% (n=399; in-hospital mortality for the ≥80-year-old group (n=139, 4.78% was significantly higher than the 20- to 49-year-old (n=9, 0.84%, P<0.001 or 50- to 79-year-old (n=251, 2.64%, P<0.001 groups. In-hospital mortality was significantly higher in the extreme SOI group (n=296, 15.33% than in the minor/moderate (n=22, 0.35%, P<0.001 and major SOI groups (n=81, 1.51%, P<0.001. Median in-hospital costs in the mild/moderate, major, and extreme SOI strata were $29,202.08, $36,035.13, and $57,572.92, respectively. Conclusion: In the minor, moderate, and major SOI groups, in-hospital mortality and costs are low regardless of age; these groups represent >85% of patients undergoing isolated AVR for aortic

  13. Air riding seal with purge cavity

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, Thomas D; Mills, Jacob A

    2017-08-15

    An air riding seal for a turbine in a gas turbine engine, where an annular piston is axial moveable within an annular piston chamber formed in a stator of the turbine and forms a seal with a surface on the rotor using pressurized air that forms a cushion in a pocket of the annular piston. A purge cavity is formed on the annular piston and is connected to a purge hole that extends through the annular piston to a lower pressure region around the annular piston or through the rotor to an opposite side. The annular piston is sealed also with inner and outer seals that can be a labyrinth seal to form an additional seal than the cushion of air in the pocket to prevent the face of the air riding seal from overheating.

  14. Purging of untrustworthy recommendations from a grid

    CERN Document Server

    Kumar, P Suresh; Ramachandram, S

    2012-01-01

    In grid computing, trust has massive significance. There is lot of research to propose various models in providing trusted resource sharing mechanisms. The trust is a belief or perception that various researchers have tried to correlate with some computational model. Trust on any entity can be direct or indirect. Direct trust is the impact of either first impression over the entity or acquired during some direct interaction. Indirect trust is the trust may be due to either reputation gained or recommendations received from various recommenders of a particular domain in a grid or any other domain outside that grid or outside that grid itself. Unfortunately, malicious indirect trust leads to the misuse of valuable resources of the grid. This paper proposes the mechanism of identifying and purging the untrustworthy recommendations in the grid environment. Through the obtained results, we show the way of purging of untrustworthy entities.

  15. AP600 containment purge radiological analysis

    Energy Technology Data Exchange (ETDEWEB)

    O`Connor, M.; Schulz, J.; Tan, C. [Bechtel Power Corporation (United States)] [and others

    1995-02-01

    The AP600 Project is a passive pressurized water reactor power plant which is part of the Design Certification and First-of-a-Kind Engineering effort under the Advanced Light Water Reactor program. Included in this process is the design of the containment air filtration system which will be the subject of this paper. We will compare the practice used by previous plants with the AP600 approach to meet the goals of industry standards in sizing the containment air filtration system. The radiological aspects of design are of primary significance and will be the focus of this paper. The AP600 Project optimized the design to combine the functions of the high volumetric flow rate, low volumetric flow rate, and containment cleanup and other filtration systems into one multi-functional system. This achieves a more simplified, standardized, and lower cost design. Studies were performed to determine the possible concentrations of radioactive material in the containment atmosphere and the effectiveness of the purge system to keep concentrations within 10CFR20 limits and within offsite dose objectives. The concentrations were determined for various reactor coolant system leakage rates and containment purge modes of operation. The resultant concentrations were used to determine the containment accessibility during various stages of normal plant operation including refueling. The results of the parametric studies indicate that a dual train purge system with a capacity of 4,000 cfm per train is more than adequate to control the airborne radioactivity levels inside containment during normal plant operation and refueling, and satisfies the goals of ANSI/ANS-56.6-1986 and limits the amount of radioactive material released to the environment per ANSI/ANS 59.2-1985 to provide a safe environment for plant personnel and offsite residents.

  16. Molds in Brined Cucumbers: Cause of Softening During Air-Purging of Fermentations †

    Science.gov (United States)

    Costilow, Ralph N.; Gates, Karen; Lacy, Melvyn L.

    1980-01-01

    Softening of cucumbers in fermentations purged at high air-flow rates was caused by molds growing in the brined cucumbers, not in the brine. This conclusion is based on the following results: (i) no microorganisms were isolated in significant numbers from brines that caused softening of pasteurized brined cucumbers, (ii) no pectinolytic enzyme activities were produced in cucumber brines in the absence of cucumbers, (iii) the pickles in some air-purged fermentations became very soft without the appearance of any pectinolytic enzyme activity in the brine, (iv) mold hyphae were consistently observed in tissues of soft pickles, (v) molds consistently developed in cultures of slices of surface sterilized cucumbers taken from fermentations in which soft pickles were subsequently found, and (vi) molds belonging to the genera Alternaria, Fusarium, and Mucor isolated from slices all softened pasteurized brined cucumbers. Images PMID:16345619

  17. New Approach to Purging Monitoring Wells: Lower Flow Rates Reduce Required Purging Volumes and Sample Turbidity

    Science.gov (United States)

    It is generally accepted that monitoring wells must be purged to access formation water to obtain “representative” ground water quality samples. Historically anywhere from 3 to 5 well casing volumes have been removed prior to sample collection to evacuate the standing well water...

  18. Whitey SCHE Gauge and Root Valves

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-11

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHa System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHa supply line.

  19. Whitey SCHE Gauge and Root Valves

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  20. Isolated native tricuspid valve endocarditis presenting as PUO in a young adult male without any risk factors

    Directory of Open Access Journals (Sweden)

    Piyush Ranjan

    2015-01-01

    Full Text Available A 28-year-old male presented to our hospital with high-grade fever and weight loss for 4 months. Clinical examination was non-contributory and there was no history of any high-risk behavior or prolonged skin or dental infections. Native tricuspid-valve endocarditis may rarely present in these settings and high index of suspicion is essential for early diagnosis.

  1. 46 CFR 154.1125 - Pipes, fittings, and valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pipes, fittings, and valves. 154.1125 Section 154.1125... Firefighting § 154.1125 Pipes, fittings, and valves. (a) Each pipe, fitting, and valve for each water spray... listed in § 154.1110 must have at least one isolation valve at each branch connection and at least...

  2. Transient stress analysis of the main steam isolation valve during the load case ''fast opening of the main steam isolation valve''; Transiente Spannungsanalyse des Gehaeuses eines aeusseren Frischdampfisolierventils beim Lastfall ''Schnelles Oeffnen des Frischdampfisolierventils''

    Energy Technology Data Exchange (ETDEWEB)

    Pacharzina, B.; Uptmoor, H. [Westinghouse Electric Germany GmbH, Mannheim (Germany)

    2008-07-01

    The structural integrity was demonstrated for a German NPP including the load case ''fast opening of the main steam isolation valve''. Since the verification of the armature housing integrity was not possible using the component specific method according KTA 3201.2 a detailed finite element analysis using the ANSYS-FE code and elastic material characteristics was performed. The considered loads include operating weight, internal pressure, restrained thermal expansion, and fluid dynamical loads. For the damping behavior according KTA 2201.4 (earth quakes) a damping factor of 4% of the critical damping was assumed. The stress analysis was performed and evaluated.

  3. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  4. Update on Advection-Diffusion Purge Flow Model

    Science.gov (United States)

    Brieda, Lubos

    2015-01-01

    Gaseous purge is commonly used in sensitive spacecraft optical or electronic instruments to prevent infiltration of contaminants and/or water vapor. Typically, purge is sized using simplistic zero-dimensional models that do not take into account instrument geometry, surface effects, and the dependence of diffusive flux on the concentration gradient. For this reason, an axisymmetric computational fluid dynamics (CFD) simulation was recently developed to model contaminant infiltration and removal by purge. The solver uses a combined Navier-Stokes and Advection-Diffusion approach. In this talk, we report on updates in the model, namely inclusion of a particulate transport model.

  5. Self-Rupturing Hermetic Valve

    Science.gov (United States)

    Tucker, Curtis E., Jr.; Sherrit, Stewart

    2011-01-01

    For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self

  6. Verification of the ASTM G-124 Purge Equation

    Science.gov (United States)

    Robbins, Katherine E.; Davis, Samuel Eddie

    2009-01-01

    ASTM G-124 seeks to evaluate combustion characteristics of metals in high-purity (greater than 99%) oxygen atmospheres. ASTM G-124 provides the following equation to determine the minimum number of purges required to reach this level of purity in a test chamber: n = -4/log10(Pa/Ph), where "n" is the total number of purge cycles required, Ph is the absolute pressure used for the purge on each cycle and Pa is the atmospheric pressure or the vent pressure. The origin of this equation is not known and has been the source of frequent questions as to its accuracy and reliability. This paper shows the derivation of the G-124 purge equation, and experimentally explores the equation to determine if it accurately predicts the number of cycles required.

  7. A dangerous combination of binge and purge.

    Science.gov (United States)

    Culkin, Alison; Gabe, Simon M; Peake, Simon T C; Stern, Julian M

    2012-03-01

    We present a 36-year-old female diagnosed with Crohn's disease at the age of 11 years. In 2001, she underwent a total colectomy and further small bowel resection as a result of active Crohn's. Her residual anatomy consisted of 150 cm of small bowel to an end jejunostomy. Subsequently, she developed short bowel syndrome with recurrent episodes of hypomagnesaemia, hypocalcaemia, and hypokalaemia. Dietetic assessment revealed her to be severely underweight at 37 kg with a bodymass index (BMI) of 14.4 kg/m(2) . During her admission, our patient underwent psychiatric assessment and was established on home parenteral nutrition (HPN). At the time of discharge, 1 month later, her weight had increased to 44 kg (BMI = 17.7 kg/m(2) ). Over the following 12-month period, she lost weight (BMI, 15.4 mg/m(2) ; weight, 39.5 kg) and she described a high stoma output (up to 17 L) and dehydration. Assessment of her oral intake found she was consuming an estimated 14,000 kcal and 600 g protein per day. At this time, the possibility of a new form of eating disorder was discussed with the patient and she agreed that her behavior i.e., using her stoma as a purging device, fulfilled the criteria for a diagnosis of bulimia nervosa and she was referred to a specialist eating disorder unit.

  8. Biochemical and molecular characteristics of Listeria monocytogenes isolates from a prosthetic mitral heart valve-bearing patient´s blood cultures

    Directory of Open Access Journals (Sweden)

    Nilma Cintra Leal

    2013-09-01

    Full Text Available Background: In Brazil, listeriosis is not a notifiable disease; thus, the incidence of Brazilian cases remains unknown. Listeria monocytogenes is not always included in automated systems, and its detection depends on the high skill level of microbiology laboratory professionals. This paper describes the characteristics of L. monocytogenes isolates fortuitously obtained from an endocarditis case in Recife, PE, Brazil. Methods: Six bacterial isolates obtained from six blood cultures from a 28-year-old male bearing a prosthetic mitral heart valve were analyzed by PCR using primers specific of L. monocytogenes to confirm a presumptive identification, determine the serotype and presence of the virulence genes (inlA, inlB, inlC, inlJ, hly, plcA, actA, prfA in an attempt to determine the Listeria genotype by PCR-ribotyping. Results: The samples were identified as L. monocytogenes 4b. All investigated virulence genes were amplified by PCR, and the identity of the amplified segments was confirmed by sequencing. A deletion of 105 base pairs was detected in the actA gene. All of the samples generated the same PCR-ribotype pattern, clustered into a single ribotype, and were considered a single strain. Conclusion: L. monocytogenes infection should be considered in endocarditis differential diagnoses, especially among high-risk groups, due to its high pathogenicity and the environmental ubiquity.

  9. BIOCHEMICAL AND MOLECULAR CHARACTERISTICS OF LISTERIA MONOCYTOGENES ISOLATES FROM A PROSTHETIC MITRAL HEART VALVE-BEARING PATIENT´S BLOOD CULTURES

    Directory of Open Access Journals (Sweden)

    Nilma Cintra Lea

    2013-09-01

    Full Text Available Background: In Brazil, listeriosis is not a notifiable disease; thus, the incidence of Brazilian cases remains unknown. Listeria monocytogenes is not always included in automated systems, and its detection depends on the high skill level of microbiology laboratory professionals. This paper describes the characteristics of L. monocytogenes isolates fortuitously obtained from an endocarditis case in Recife, PE, Brazil. Methods: Six bacterial isolates obtained from six blood cultures from a 28-year-old male bearing a prosthetic mitral heart valve were analyzed by PCR using primers specific of L. monocytogenes to confirm a presumptive identification, determine the serotype and presence of the virulence genes (inlA, inlB, inlC, inlJ, hly, plcA, actA, prfA in an attempt to determine the Listeria genotype by PCR-ribotyping. Results: The samples were identified as L. monocytogenes 4b. All investigated virulence genes were amplified by PCR, and the identity of the amplified segments was confirmed by sequencing. A deletion of 105 base pairs was detected in the actA gene. All of the samples generated the same PCR-ribotype pattern, clustered into a single ribotype, and were considered a single strain. Conclusion: L. monocytogenes infection should be considered in endocarditis differential diagnoses, especially among high-risk groups, due to its high pathogenicity and the environmental ubiquity.

  10. Valve's Way

    Directory of Open Access Journals (Sweden)

    Phanish Puranam

    2015-06-01

    Full Text Available What can we learn from outliers? While statisticians rightly warn us against their non-representativeness, we believe it is also true that thinking carefully about what makes them atypical may improve our understanding of the typical case. This is the premise behind the Organization Zoo series. Valve Corporation (Valve is an unusual firm. It is a rare example of a firm that appears to operate without any formal hierarchy in its organization. What can we learn about the viability of authority hierarchies from Valve’s way of organizing? We wrote a brief account of Valve based on public information sources and asked several renowned organizational experts to comment on this unusual firm. We asked them to write a short commentary on what the Valve example means for organizational theorists and practitioners. Thankfully, they all accepted, and we are excited to present the results of their thinking in this first “exhibit” in the Organization Zoo.

  11. Purging and isolating pluripotent cells, "sweet" dreams become true?

    Institute of Scientific and Technical Information of China (English)

    Ignacio Sancho-Martinez; Emmanuel Nivet; Juan Carlos Izpisua Belmonte

    2011-01-01

    The formation of an adult organism could be viewed as a hierarchical process in which the initial totipotent cell,the zygote,progressively loses "potency" by differentiating into pluripotent,multipotent and unipotent states until the final terminally differentiated cells comprising tissues and organs are derived.Such a unidirectional concept trembled when four transcription factors were shown to "revert" the identity of differentiated somatic cells and reprogram them into induced pluripotent stem cells (iPSCs) [1].

  12. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  13. The pro-Franco purge of the primary teaching profession

    Directory of Open Access Journals (Sweden)

    Juan Manuel FERNÁNDEZ SORIA

    2013-11-01

    Full Text Available The purge of primary school teaching profession, like other groups, was an instrument of political repression organized and planned in order to establish, keep and legitimise the social-political «New Order» that aroze after the victory of Franco's army. There are three points to this article. The first point establishes the state of the question on the repressive nature and conditions in Franco's Spain. The repression adopted against the school teachers has its own quality: it is more preventive than punitive, trying with it to dissuade the pedagogue action of the teaching profession, a group who never had the confidence of the new regime nor the ideological mainstays which support it, including the catolical church. The second point tries to clear this mistrust, which goes back to the times of the Spanish Second Republic; in this mistrust the purge of the schoolteachers has its arguments. The third part studies the purge of Valencian schoolteachers, and analyses its political and social characteristics, concluding that an apolitical and scantily compromised group is purged essentially due to political accusations. Though the accusations were not harsh we can confirm the hypothesis of the preventive purge of the teaching profession, a group the Franco regime needed but kept by fear. The great lozers of this repression were not only the school teachers but the Spanish society itself. A society that saw how the new pedagogy under Franco's regime cut the progress that was finally underway only a few years prior.

  14. Solute transport in a well under slow-purge and no-purge conditions

    Science.gov (United States)

    Plummer, M. A.; Britt, S. L.; Martin-Hayden, J. M.

    2010-12-01

    Non-purge sampling techniques, such as diffusion bags and in-situ sealed samplers, offer reliable and cost-effective groundwater monitoring methods that are a step closer to the goal of real-time monitoring without pumping or sample collection. Non-purge methods are, however, not yet completely accepted because questions remain about how solute concentrations in an unpurged well relate to concentrations in the adjacent formation. To answer questions about how undisturbed well water samples compare to formation concentrations, and to provide the information necessary to interpret results from non-purge monitoring systems, we have conducted a variety of physical experiments and numerical simulations of flow and transport in and through monitoring wells under low-flow and ambient flow conditions. Previous studies of flow and transport in wells used a Darcy’s law - based continuity equation for flow, which is often justified under the strong, forced-convection flow caused by pumping or large vertical hydraulic potential gradients. In our study, we focus on systems with weakly forced convection, where density-driven free convection may be of similar strength. We therefore solved Darcy’s law for porous media domains and the Navier Stokes equations for flow in the well, and coupled solution of the flow equations to that of solute transport. To illustrate expected in-well transport behavior under low-flow conditions, we present results of three particular studies: (1) time-dependent effluent concentrations from a well purged at low-flow pumping rates, (2) solute-driven density effects in a well under ambient horizontal flow and (3) temperature-driven mixing in a shallow well subject to seasonal temperature variations. Results of the first study illustrate that assumptions about the nature of in-well flow have a significant impact on effluent concentration curves even during pumping, with Poiseuille-type flow producing more rapid removal of concentration differences

  15. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  16. Inbreeding depression is purged in the invasive insect Harmonia axyridis.

    Science.gov (United States)

    Facon, Benoît; Hufbauer, Ruth A; Tayeh, Ashraf; Loiseau, Anne; Lombaert, Eric; Vitalis, Renaud; Guillemaud, Thomas; Lundgren, Jonathan G; Estoup, Arnaud

    2011-03-08

    Bottlenecks in population size reduce genetic diversity and increase inbreeding, which can lead to inbreeding depression. It is thus puzzling how introduced species, which typically pass through bottlenecks, become such successful invaders. However, under certain theoretical conditions, bottlenecks of intermediate size can actually purge the alleles that cause inbreeding depression. Although this process has been confirmed in model laboratory systems, it has yet to be observed in natural invasive populations. We evaluate whether such purging could facilitate biological invasions by using the world-wide invasion of the ladybird (or ladybug) Harmonia axyridis. We first show that invasive populations endured a bottleneck of intermediate intensity. We then demonstrate that replicate introduced populations experience almost none of the inbreeding depression suffered by native populations. Thus, rather than posing a barrier to invasion as often assumed, bottlenecks, by purging deleterious alleles, can enable the evolution of invaders that maintain high fitness even when inbred. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Recovery of nitrogen and light hydrocarbons from polyalkene purge gas

    Science.gov (United States)

    Zwilling, Daniel Patrick; Golden, Timothy Christoph; Weist, Jr., Edward Landis; Ludwig, Keith Alan

    2003-06-10

    A method for the separation of a gas mixture comprises (a) obtaining a feed gas mixture comprising nitrogen and at least one hydrocarbon having two to six carbon atoms; (b) introducing the feed gas mixture at a temperature of about 60.degree. F. to about 105.degree. F. into an adsorbent bed containing adsorbent material which selectively adsorbs the hydrocarbon, and withdrawing from the adsorbent bed an effluent gas enriched in nitrogen; (c) discontinuing the flow of the feed gas mixture into the adsorbent bed and depressurizing the adsorbent bed by withdrawing depressurization gas therefrom; (d) purging the adsorbent bed by introducing a purge gas into the bed and withdrawing therefrom an effluent gas comprising the hydrocarbon, wherein the purge gas contains nitrogen at a concentration higher than that of the nitrogen in the feed gas mixture; (e) pressurizing the adsorbent bed by introducing pressurization gas into the bed; and (f) repeating (b) through (e) in a cyclic manner.

  18. Excess flow shutoff valve

    Energy Technology Data Exchange (ETDEWEB)

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  19. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  20. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  1. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    Puranam and Håkonsson (2015) challenge us to ponder what we as organization design theorists make of Valve’s way (see also Jeppesen, 2008). We believe that Valve, in spite of its radical vision, does not represent a challenge to fundamental organization design theory and that it is questionable...

  2. "Vanishing" pulmonary valve stenosis

    Directory of Open Access Journals (Sweden)

    Nofil I Arain

    2012-01-01

    Full Text Available Objective: Both spontaneous resolution and progression of mild pulmonary valve stenosis (PS have been reported. We reviewed characteristics of the pulmonary valve (PV to determine factors that could influence resolution of mild PS. Methods: Fifteen asymptomatic pediatric patients with spontaneous resolution of isolated mild PS were retrospectively reviewed. Results: There was no correlation between the PV gradient, clinical presentation, age at diagnosis, or PV morphology. The PV annulus was small at initial presentation, which normalized at follow up. When corrected for the body surface area (z-score, the PV annulus was normal in all patients, including at initial evaluation. Conclusions: Based on our observation, neither age at diagnosis, nor PV-morphology-influenced resolution of mild PS. The variable clinical presentation makes it difficult to categorize and observe mild PS by auscultation alone. The PV annulus z-score could be a useful adjunct to determine the course and serial observation of mild PS.

  3. 49 CFR 230.52 - Water glass valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Water glass valves. 230.52 Section 230.52... Water Glasses and Gauge Cocks § 230.52 Water glass valves. All water glasses shall be equipped with no more than two valves capable of isolating the water glass from the boiler. They shall also be equipped...

  4. Propellant and Purge System Contamination "2007: A Summer of Fun"

    Science.gov (United States)

    Galloway, Randy

    2010-01-01

    This slide presentation reviews the propellant and purge system contamination that occurred during the summer of 2007 at Stennis Space Center. During this period Multiple propellant/pressurant system contamination events prompted a thorough investigation, the results of which are reviewed.

  5. Well-purging criteria for sampling purgeable organic compounds

    Science.gov (United States)

    Gibs, J.; Imbrigiotta, T.E.

    1990-01-01

    The results indicate that 1) purgeable organic compound concentrations stabilized when three casing volume were purged in only 55% of the cases evaluated in this study, 2) purgeable organic compounds concentrations did not consistently follow the temporal variation of, nor stabilize at the same time as, the measure field characteristics, and 3) purging to achieve hydraulic equilibrium between casing and aquifer water consistently underestimated the time and casing volumes needed to achieve stable values of water-quality measurements in highly transmissive aquifers. The conclusion from these data is that none of the previously recommended criteria for purging a well can be applied reliably to collecting a "representative' sample of purgeable organic compounds. These results indicate that the criteria for purging a well prior to sampling for purgeable organic compounds must take into account other factors, such as the unique hydrogeologic characteristics of a site, the nature and extent of purgeable organic compounds present, and areal extent of the contamination, the well construction, and the sampling objectives of the investigation. -from Authors

  6. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  7. Robotic mitral valve replacement.

    Science.gov (United States)

    Senay, Sahin; Gullu, Ahmet Umit; Kocyigit, Muharrem; Degirmencioglu, Aleks; Karabulut, Hasan; Alhan, Cem

    2014-01-01

    Robotic surgical techniques allow surgeons to perform mitral valve surgery. This procedure has gained acceptance, particularly for mitral valve repair in degenerative mitral disease. However, mitral repair may not always be possible, especially in severely calcified mitral valve of rheumatic origin. This study demonstrates the basic concepts and technique of robotic mitral valve replacement for valve pathologies that are not suitable for repair.

  8. Purging behavior in anorexia nervosa and eating disorder not otherwise specified

    DEFF Research Database (Denmark)

    Støving, René Klinkby; Andries, Alin; Brixen, Kim Torsten

    2012-01-01

    Purging behavior in eating disorders is associated with medical risks. We aimed to compare remission rates in purging and non-purging females with anorexia nervosa (AN) and eating disorder not otherwise specified (EDNOS) in a large retrospective single center cohort. A total of 339 patients...

  9. MACRO- MICRO-PURGE SOIL GAS SAMPLING METHODS FOR THE COLLECTION OF CONTAMINANT VAPORS

    Science.gov (United States)

    Purging influence on soil gas concentrations for volatile organic compounds (VOCs), as affected by sampling tube inner diameter and sampling depth (i.e., dead-space purge volume), was evaluated at different field sites. A macro-purge sampling system consisted of a standard hollo...

  10. Automatic shutoff valve

    Science.gov (United States)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  11. Adjustable safety relief valve

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, W.L.

    1990-06-12

    This patent describes a pressure relief valve having a relief set pressure. It comprises: a valve body having a fluid inlet and outlet, a spherical, metal valve seat associated with the inlet and a valve member comprising at least a portion of a spherical,metal ball attached to a ball holding element, the valve member being biased against the valve seat and thus providing a metal-to-metal seal preventing the passage of fluids past the valve seat when the fluid pressure in the inlet is below the relief pressure setting of the valve.

  12. A CONTINUOUS-PURGE PULSED VALVE SUITABLE FOR HIGH-TEMPERATURE APPLICATIONS. (R825412)

    Science.gov (United States)

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  13. Ashcroft Pressure Switch Monitor for Low SCHe Purge Pressure

    Energy Technology Data Exchange (ETDEWEB)

    VAN KATWIJK, C.

    2000-06-21

    These 0-15 psig pressure switches are located in the SCHe helium purge lines after PCV-5*23 and before PCV-5*27. The pressure switches monitor the pressure being maintained between the two PCVs and actuate on low pressure of 15 psig. This design is used for each of the SCHe supply lines (4). Electronic output signal is NON-SAFETY (GS).

  14. Evaluation of Innovative High Pulse Rate, Purged Spark Gap Concepts

    Science.gov (United States)

    1989-06-01

    gugh the switch and the pressure loss through the gas circulation system. The pressure loss is the sum of the losses in the spark gap , flow ducting...developed to solve the mass, momentum, and energy conservation equations which govern the purging process in a spark gap flow channel following arc...formation. [2,3] In this model, gas properties and spark gap flow channel area varied with distance along the flow axis from the spark gap and with

  15. The Role of Loss of Control Eating in Purging Disorder

    Science.gov (United States)

    Forney, K. Jean; Haedt-Matt, Alissa A.; Keel, Pamela K.

    2014-01-01

    Objective Purging Disorder (PD), an Other Specified Feeding or Eating Disorder,1 is characterized by recurrent purging in the absence of binge eating. Though objectively large binge episodes are not present, individuals with PD may experience a loss of control (LOC) while eating a normal or small amounts of food. The present study sought to examine the role of LOC eating in PD using archival data from 101 women with PD. Method Participants completed diagnostic interviews and self-report questionnaires. Analyses examined the relationship between LOC eating and eating disorder features, psychopathology, personality traits, and impairment, in bivariate models and then in multivariate models controlling for purging frequency, age, and body mass index. Results Across bivariate and multivariate models, LOC eating frequency was associated with greater disinhibition around food, hunger, depressive symptoms, negative urgency, and distress and impairment. Discussion LOC eating is a clinically significant feature of PD and should be considered in future definitions of PD. Future research should examine whether LOC eating better represents a dimension of severity in PD or a specifier that may impact treatment response or course. PMID:24185981

  16. Efficient purging of deleterious mutations in plants with haploid selfing

    Energy Technology Data Exchange (ETDEWEB)

    Szovenyi, Peter [Univ. of Zurich (Switzerland); Shaw, Jon [Duke Univ., Durham, NC (United States); Yang, Xiaohan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Devos, Nicolas [Duke Univ., Durham, NC (United States)

    2014-05-30

    In diploid organisms, selfing reduces the efficiency of selection in removing deleterious mutations from a population. This need not be the case for all organisms. Some plants, for example, undergo an extreme form of selfing known as intragametophytic selfing, which immediately exposes all recessive deleterious mutations in a parental genome to selective purging. Here we ask how effectively deleterious mutations are removed from such plants. Specifically, we study the extent to which deleterious mutations accumulate in a predominantly selfing and a predominantly outcrossing pair of moss species, using genome-wide transcriptome data. We find that the selfing species purge significantly more non-synonymous mutations, as well as a greater proportion of radical amino acid changes which alter physicochemical properties of amino acids. Moreover, their purging of deleterious mutation is especially strong in conserved regions of protein-coding genes. Our observations show that selfing need not impede but can even accelerate the removal of deleterious mutations, and do so on a genome-wide scale.

  17. Biofilm Removal Using Carbon Dioxide Aerosols without Nitrogen Purge.

    Science.gov (United States)

    Hong, Seongkyeol; Jang, Jaesung

    2016-11-06

    Biofilms can cause serious concerns in many applications. Not only can they cause economic losses, but they can also present a public health hazard. Therefore, it is highly desirable to remove biofilms from surfaces. Many studies on CO2 aerosol cleaning have employed nitrogen purges to increase biofilm removal efficiency by reducing the moisture condensation generated during the cleaning. However, in this study, periodic jets of CO2 aerosols without nitrogen purges were used to remove Pseudomonas putida biofilms from polished stainless steel surfaces. CO2 aerosols are mixtures of solid and gaseous CO2 and are generated when high-pressure CO2 gas is adiabatically expanded through a nozzle. These high-speed aerosols were applied to a biofilm that had been grown for 24 hr. The removal efficiency ranged from 90.36% to 98.29% and was evaluated by measuring the fluorescence intensity of the biofilm as the treatment time was varied from 16 sec to 88 sec. We also performed experiments to compare the removal efficiencies with and without nitrogen purges; the measured biofilm removal efficiencies were not significantly different from each other (t-test, p > 0.55). Therefore, this technique can be used to clean various bio-contaminated surfaces within one minute.

  18. Leakage predictions for Rayleigh-step, helium-purge seals

    Science.gov (United States)

    Proctor, Margaret P.

    1988-01-01

    Rayleigh-step, helium purge, annular shaft seals, studied for use in liquid oxygen turbopumps, generate a hydrodynamic force that enables the seal to follow shaft perturbations. Hence, smaller clearances can be used to reduce seal leakage. FLOWCAL, a computer code developed by Mechanical Technology Incorporated, predicts gas flow rate through an annular seal with an axial pressure gradient. Analysis of a 50-mm Rayleigh-step, helium-purge, annular seal showed the flow rate increased axial pressure gradient, downstream pressure, and eccentricity ratio. Increased inlet temperature reduced leakage. Predictions made at maximum and minimum clearances (due to centrifugal and thermal growths, machining tolerances and + or - 2 percent uncertainty in the clearance measurement) placed wide boundaries on expected flow rates. The widest boundaries were set by thermal growth conditions. Predicted flow rates for a 50-mm Rayleigh-step, helium-purge, annular seal underestimated measured flow rates by three to seven times. However, the analysis did accurately predict flow rates for choked gas flow through annular seals when compared to flow rates measured in two other independent studies.

  19. Valve Health Monitoring System Utilizing Smart Instrumentation

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  20. Valve-in-valve-in-valve: Treating endocarditis of a transcatheter heart valve.

    Science.gov (United States)

    Nguyen, Caroline; Cheong, Adrian P; Himbert, Dominique

    2015-10-01

    Transcatheter heart valve endocarditis is a rare, but life threatening complication. We describe the case of a patient who was successfully treated by transcatheter aortic valve-in-valve-in-valve replacement with a favorable 1-year outcome, despite severe early complications.

  1. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  2. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  3. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  4. Valve-in-Valve Replacement Using a Sutureless Aortic Valve

    Science.gov (United States)

    Dohmen, Pascal M.; Lehmkuhl, Lukas; Borger, Michael A.; Misfeld, Martin; Mohr, Friedrich W.

    2016-01-01

    Patient: Female, 61 Final Diagnosis: Tissue degeneration Symptoms: Dyspnea Medication: — Clinical Procedure: Redo valve replacement Specialty: Surgery Objective: Rare disease Background: We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. Case Report: The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biopros-thesis. The postoperative course was uneventful and the patient was discharged on day 6. Conclusions: The current case report demonstrates that sutureless bioprostheses are an attractive option for surgical valve-in-valve procedures, which can reduce morbidity and mortality. PMID:27694795

  5. Catalytic membrane reactor for tritium extraction system from He purge

    Energy Technology Data Exchange (ETDEWEB)

    Santucci, Alessia, E-mail: alessia.santucci@enea.it [ENEA for EUROfusion, Via E. Fermi 45, 00044 Frascati, Roma (Italy); Incelli, Marco [ENEA for EUROfusion, Via E. Fermi 45, 00044 Frascati, Roma (Italy); DEIM, University of Tuscia, Via del Paradiso 47, 01100 Viterbo (Italy); Sansovini, Mirko; Tosti, Silvano [ENEA for EUROfusion, Via E. Fermi 45, 00044 Frascati, Roma (Italy)

    2016-11-01

    Highlights: • In the HCBB blanket, the produced tritium is recovered by purging with helium; membrane technologies are able to separate tritium from helium. • The paper presents the results of two experimental campaigns. • In the first, a Pd–Ag diffuser for hydrogen separation is tested at several operating conditions. • In the second, the ability of a Pd–Ag membrane reactor for water decontamination is assessed by performing isotopic swamping and water gas shift reactions. - Abstract: In the Helium Cooled Pebble Bed (HCPB) blanket concept, the produced tritium is recovered purging the breeder with helium at low pressure, thus a tritium extraction system (TES) is foreseen to separate the produced tritium (which contains impurities like water) from the helium gas purge. Several R&D activities are running in parallel to experimentally identify most promising TES technologies: particularly, Pd-based membrane reactors (MR) are under investigation because of their large hydrogen selectivity, continuous operation capability, reliability and compactness. The construction and operation under DEMO relevant conditions (that presently foresee a He purge flow rate of about 10,000 Nm{sup 3}/h and a H{sub 2}/He ratio of 0.1%) of a medium scale MR is scheduled for next year, while presently preliminary experiments on a small scale reactor are performed to identify most suitable operative conditions and catalyst materials. This work presents the results of an experimental campaign carried out on a Pd-based membrane aimed at measuring the capability of this device in separating hydrogen from the helium. Many operative conditions have been investigated by considering different He/H{sub 2} feed flow ratios, several lumen pressures and reactor temperatures. Moreover, the performances of a membrane reactor (composed of a Pd–Ag tube having a wall thickness of about 113 μm, length 500 mm and diameter 10 mm) in processing the water contained in the purge gas have been

  6. Process sampling module coupled with purge and trap-GC-FID for in situ auto-monitoring of volatile organic compounds in wastewater.

    Science.gov (United States)

    Liu, Hsin-Wang; Liu, Yung-Tsun; Wu, Bei-Zen; Nian, Hung-Chi; Chen, Hsing-Jung; Chiu, Kong-Hwa; Lo, Jiunn-Guang

    2009-12-15

    An automatic sampling device, i.e., process sampling module (PSM), connected with a purge and trap-GC-FID system has been developed for real-time monitoring of VOCs in wastewater. The system was designed to simultaneously monitor 17 compounds, including one polar compound, i.e., acetone, and 16 non-polar compounds. The trapping tube is packed with two adsorbents, Carbopack B and Carbosieve III, to trap target compounds. For the purpose of in situ monitoring, the flush valve of the sampling tube is composed of two two-way valves and a time controller to prevent absorption interference of the residue. The optimal conditions for the analytical system include a 12 min purge time at a temperature of 60 degrees C, and 4 min of desorption time with a desorption temperature of 260 degrees C. Good chromatograms have been obtained with the analytical system even if a cryogenic device and de-misting were not used. The relative standards deviation (RSD) of the system is between 2% and 13.4%, and accuracies between 0.3 and 23.5% have been achieved. The detection limits of the method range from 0.32 to 2.39 ppb. In this system, the four parts, i.e., PSM, P&T, GC, and FID, were simple, reliable and rugged. Also, the interface of these four parts was simple and dependable.

  7. Whole Teflon valves for handling droplets.

    Science.gov (United States)

    Cybulski, Olgierd; Jakiela, Slawomir; Garstecki, Piotr

    2016-06-21

    We propose and test a new whole-Teflon gate valve for handling droplets. The valve allows droplet plugs to pass through without disturbing them. This is possible due to the geometric design, the choice of material and lack of any pulses of flow generated by closing or opening the valve. The duct through the valve resembles a simple segment of tubing, without constrictions, change in lumen or side pockets. There are no extra sealing materials with different wettability or chemical resistance. The only material exposed to liquids is FEP Teflon, which is resistant to aggressive chemicals and fully biocompatible. The valve can be integrated into microfluidic systems: we demonstrate a complex system for culturing bacteria in hundreds of microliter droplet chemostats. The valve effectively isolates modules of the system to increase precision of operations on droplets. We verified that the valve allowed millions of droplet plugs to safely pass through, without any cross-contamination with bacteria between the droplets. The valve can be used in automating complex microfluidic systems for experiments in biochemistry, biology and organic chemistry.

  8. Ongoing Technology and Developing Trend of Ar-blowing Purging Plug

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    An introduction of the ongoing technology of ar-gon-blowing purging plugs in China was presented in this work.Gel powders were used as starting materials to enhance the high temperature mechanical properties of the purging plugs.Composite purging plug adopting ex-trusion formed gas-purging bar and slit had its surface structural design improved,which enhanced the resist-ances to thermal shock and molten steel penetration,prolonging the service life.In addition,the safety Was greatly improved by upgrading the framework and pro-duction process,enhancing the resistance to breakout.It is indicated that the developing trend is to produce pur-ging plugs of longer service life and better gas purging rate with different starting materials and structure de-signs to meet the requirements of various metallurgical processes.

  9. Facets of negative affect prior to and following binge-only, purge-only, and binge/purge events in women with bulimia nervosa.

    Science.gov (United States)

    Berg, Kelly C; Crosby, Ross D; Cao, Li; Peterson, Carol B; Engel, Scott G; Mitchell, James E; Wonderlich, Stephen A

    2013-02-01

    Ecological momentary assessment (EMA) data suggest that global negative affect (NA) increases prior to and decreases following episodes of binge eating and purging, providing support for the affect regulation model of BN. The current study examined whether facets of NA are differentially related to bulimic behaviors. Women with bulimia nervosa (BN; n = 133) completed a 2-week EMA protocol. Momentary assessments of 4 facets of NA (Fear, Guilt, Hostility, and Sadness) were derived from the PANAS subscales. Trajectories of the NA facets were modeled prior to and following binge-only, purge-only, and binge/purge events. Fear, Guilt, Hostility, and Sadness increased prior to and decreased following binge-only and binge/purge events. The same results were found for purge-only events, with the exception that Hostility did not increase significantly prior to purging. Notably, ratings of Guilt were higher than those of Fear, Hostility, and Sadness at the time of binge-only and binge/purge events. Furthermore, post hoc analyses demonstrate that Guilt increased prior to and decreased following the 3 behavior types, even after controlling for Fear, Hostility, and Sadness. These results provide further support for the affect regulation model of BN and also suggest that guilt may be particularly important to the pathology of BN.

  10. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  11. Surgical treatment management offor isolated bicuspid aortic stenosis in patients with bicuspid aortic valve%主动脉瓣二瓣畸形所致主动脉瓣狭窄的外科治疗

    Institute of Scientific and Technical Information of China (English)

    崔永超; 周其文; 来永强; 李进华; 赖以恒; 李景伟; 郝兴海; 章良; 戴江; 孟旭

    2009-01-01

    Objective Bicuspid aortic valve is thea most common reason cause forof aortic valve replacment in patients with isolated aortic stenosis. Severe valve calcification and ascending aorta dilation are often related to the bicuspid aortic valve. Proper surgical intervention of these patients are very importing, and it may improve affed.the long-term results.Our experience in surgical management of isolated aortic stenosis in atients with bicuspid aortic valve is reported. Methods From May. 1993 to Dec. 2007, 103 consecutive patients' data with of isolated aortic stenosis and with bicuspid aortic valve underwent surgery icalwere collected and analyzed treatm.ent. There were 66 males and 37 females, and aAge ranged from 15 years to75 years [mean(52.9±3.2 )years]. 58 Fifty eight patients were in heart function (NYHA) class Ⅱ, 33 cases were in class Ⅲ, and 12 cases in class Ⅳ. All patients received aortic valve replacement. Severe aortci aortic valve calcification existed were found in 55 patients,and ascending aorta dilation (aorta diameter largerthan > 4.5 cm) occurred in 7 cases. Concomitant procedures were as followingfollows: left ventricular out-flow obstruct correction in 2 cases, radio-frequency ablation for atrial fibrillation in 2 cases, ascending area replacement in 7 cases, and coronary artery bypass graft in 11 cases. Results Operative death occurred in 1 patient (mortality0.93%). Complete atrioventricular block occurred in 1 patient. Others The rest were all recovered and discharged. The follow-up ranged duration were from 6 months to 14 years [ (86.3 ± 6.8) months].14 casesFourteen patients lost in the follow-up. Three cases had Bbrain complications, occurred in 3 cases. Sudden death and no-cardiac death occurred in 1 patient, respectively. Heart function improved significantly after operation. 67 patients were in function class 1, 17patients were in Ⅱ, and 2 in class Ⅲ at the latest follow-up. Conclusion Aortic valvereplacement is an effective

  12. Remote manual operator for space station intermodule ventilation valve

    Science.gov (United States)

    Guyaux, James R.

    1996-01-01

    The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

  13. Culture-negative prosthetic valve endocarditis with concomitant septicemia due to a nontoxigenic Corynebacterium diphtheriae biotype gravis isolate in a patient with multiple risk factors.

    Science.gov (United States)

    Clinton, Lani Kai; Bankowski, Matthew J; Shimasaki, Teppei; Sae-Ow, Wichit; Whelen, A Christian; O'Connor, Norman; Kim, Wesley; Young, Royden

    2013-11-01

    A 54-year-old female with a prosthetic mitral valve presented with a 3-day history of dizziness, subjective fever, and chills. Blood cultures were positive for a pleomorphic Gram-positive rod. Initial phenotypic testing could only support the identification of a Corynebacterium species. Nucleic acid sequencing (16S rRNA) and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) were conclusive for Corynebacterium diphtheriae. Definitive phenotypic testing classified the strain as nontoxigenic C. diphtheriae biotype Gravis.

  14. Aortic Valve Regurgitation

    Science.gov (United States)

    ... inside your heart that involves heart valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a ... the United States — can damage the aortic valve. Rheumatic fever is still prevalent in developing countries but rare ...

  15. Pulmonary Valve Stenosis

    Science.gov (United States)

    ... growths called carcinoid tumors in the digestive system. Rheumatic fever. This complication of an infection caused by streptococcus ... valve stenosis later in life, including: Carcinoid syndrome Rheumatic fever Noonan's syndrome Mild to moderate pulmonary valve stenosis ...

  16. Aortic Valve Disease

    Science.gov (United States)

    ... Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Pediatric and Congenital Heart Disease Heart abnormalities that are ... Transplantation End-stage Lung Disease Adult Lung Transplantation Pediatric Lung ... Aortic Aneurysm Aortic Valve Disease Overview The human heart has ...

  17. Mitral Valve Stenosis

    Science.gov (United States)

    ... up around the ring around the mitral valve (annulus), which can occasionally cause mitral valve stenosis. Other ... the condition of your lungs. Transesophageal echocardiogram. A small transducer attached to the end of a tube ...

  18. Heart valve surgery

    Science.gov (United States)

    ... Tricuspid valve stenosis Risks The risks of having cardiac surgery include: Death Heart attack Heart failure Bleeding requiring ... and the A.D.A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Latest ...

  19. Aerodynamic Shutoff Valve

    Science.gov (United States)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  20. Isolamento das veias pulmonares em pacientes com fibrilação atrial permanente secundária a valvopatia mitral Isolation of the pulmonary veins in patients with permanent atrial fibrillation secondary to mitral valve disease

    Directory of Open Access Journals (Sweden)

    Gustavo G. Lima

    2004-04-01

    Full Text Available OBJETIVO: Analisar a eficácia do isolamento cirúrgico das veias pulmonares para restabelecer ritmo sinusal em pacientes com fibrilação atrial secundária à doença mitral. MÉTODOS: 33 pacientes com indicação de correção cirúrgica da valva mitral e com fibrilação atrial permanente, foram submetidos ao isolamento cirúrgico das veias pulmonares, sendo 67% mulheres. Média de idade de 56,3±10 anos, classe funcional NYHA pré-operatória de 3,2±0,6, tamanho de átrio esquerdo de 5,5± 0,9 cm, fração de ejeção de 61,3±13%. A técnica cirúrgica consistiu de incisão circunferencial ao redor das 4 veias pulmonares, excisão do apêndice atrial esquerdo e de incisão perpendicular desde a borda inferior da incisão, isolando as veias pulmonares, até o ânulo da valva mitral. Arritmias precoces foram tratadas, agressivamente, com cardioversão. RESULTADOS: O seguimento médio foi de 23,9±17 meses e ocorreram 3 óbitos no pós-operatório. Dez pacientes necessitaram de cardioversão elétrica no pós-operatório; 87% apresentavam ritmo sinusal na última consulta e 33% estavam em uso de amiodarona. CONCLUSÃO: Isolamento das veias pulmonares associado à cirurgia da valva mitral é uma técnica efetiva e segura na manutenção de ritmo sinusal em pacientes com fribilação atrial permanente.OBJECTIVE: To assess the efficacy of surgical isolation of the pulmonary veins for re-establishing sinus rhythm in patients with atrial fibrillation secondary to mitral valve disease. METHODS: Thirty-three (67% were women patients with permanent atrial fibrillation and indication for surgical correction of the mitral valve underwent surgical isolation of the pulmonary veins. Their mean age was 56.3±10 years, preoperative NYHA functional class was 3.2±0.6, left atrial size was 5.5±0.9 cm, and ejection fraction was 61.3±13%. The surgical technique consisted of a circumferential incision surrounding the 4 pulmonary veins, excision of the left

  1. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  2. Dump valve assembly

    Science.gov (United States)

    Owen, T.J.

    1984-01-01

    A dump valve assembly comprising a body having a bore defined by a tapered wall and a truncated spherical valve member adapted to seat along a spherical surface portion thereof against said tapered wall. Means are provided for pivoting said valve member between a closed position engagable with said tapered wall and an open position disengaged therefrom.

  3. Behavioral, emotional, and situational context of purging episodes in anorexia nervosa

    Science.gov (United States)

    Goldschmidt, Andrea B.; Accurso, Erin C.; Schreiber-Gregory, Deanna N.; Crosby, Ross D.; Cao, Li; Engel, Scott G.; Mitchell, James E.; Crow, Scott J.; Peterson, Carol B.; Le Grange, Daniel; Wonderlich, Stephen A.

    2015-01-01

    Objective The current study examined behavioral, emotional, and situational factors involved in purging among women with anorexia nervosa (AN). Methods Women with AN (n=118) completed a two-week ecological momentary assessment protocol involving daily reports of eating disorder behaviors, mood, and stressful events. Generalized estimating equations examined the likelihood and context of purging following eating episodes involving both overeating and loss of control (binge eating; BE); loss of control only (LOC); overeating only (OE); and neither loss of control nor overeating (non-pathological eating; NE). Results Relative to NE, purging was more likely to occur following BE, LOC, and OE (Wald chi-square=18.05; p<.001). BE was more strongly associated with subsequent purging than LOC but not OE; the latter two did not differ from one another. Negative affect predicted purging following NE (Wald chi-square=7.71; p=.005). Conclusion Binge eating involving large amounts of food was the strongest predictor of purging in AN, which challenges the notion that loss of control is the most salient aspect of experiencing distress in bulimia nervosa and binge eating disorder. Parallel to findings from the binge eating literature, negative affect strongly predicted purging following non-pathological eating. Further research should clarify the function and triggers of purging in AN. PMID:25643935

  4. From Promise to Purge: The First Years of St. Petersburg University.

    Science.gov (United States)

    Whittaker, Cynthia H.

    1978-01-01

    Discusses the development of St. Petersburg University, Russia, from its inception in 1819 when it was composed of dedicated, eager scholars to the purges in 1821. Concludes that Tsar Alexander I was instrumental in these purges because of his fear that the ideals of European enlightenment in education and politics fostered by the university would…

  5. Chinese Standards on Refractories Purging Plugs and Well Blocks for Refining Ladle

    Institute of Scientific and Technical Information of China (English)

    Zhang Xiaohui

    2009-01-01

    @@ 1 Scope This standard specifies the classification,technical requirements,test methods,inspection rules,marking,packing,transportation,storage and quality certificate of purging plugs and well blocks for refining ladle. This standard is applicable to the directional slit purging plugs and well blocks for refining ladle.

  6. ANALYSIS OF PENTACHLOROPHENOL IN WATER BY PURGE AND TRAP CONCENTRATOR COUPLED TOGAS CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    Huixia Lan; Yuancai Chen; Zhonghao Chen

    2004-01-01

    It is convenient and time saving to analyze pentachlorophenol (PCP) in water by purge and trap concentrator coupled to gas chromatography that avoids employing a great deal of organic solvent: In this paper, the appropriate purge and trap conditions of PCP are determined: the trapped sorbent is TenaxGC; the purge gas is pure nitrogen and purge flow is 40ml/min; the purge time is 30min. A series of standard PCP water samples 5, 10, 50, 100, 200,400, 800, 1000ppb are analyzed in order to obtain standard curve, and the linear regressive equation obtained is Y=109.65X-687.72, which correlation coefficient r is 0.9949. The precision of the method is determined with 0.5ppb PCP water sample, and the standard deviation measured is 3%. The detection limit for PCP is 0.2ppb.

  7. ANALYSIS OF PENTACHLOROPHENOL IN WATER BY PURGE AND TRAP CONCENTRATOR COUPLED TO GAS CHROMATOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    HuixiaLan; YuancaiChen; ZhonghaoChen

    2004-01-01

    It is convenient and time saving to analyze pentachlorophenol (PCP) in water by purge and trap concentrator coupled to gas chromatography that avoids employing a great deal of organic solvent. In this paper, the appropriate purge and trap conditions of PCP are determined: the trapped sorbent is TenaxGC; the purge gas is pure nitrogen and purge flow is 40ml/min; the purge time is 30min. A series of standard PCP water samples 5, 10, 50, 100, 200, 400, 800, 1000ppb are analyzed in order to obtain standard curve, and the linear regressive equation obtained is Y=109.65X-687.72, which correlation coefficient r is 0.9949. The precision of the method is determined with 0.5ppb PCP water sample, and the standard deviation measured is 3%. The detection limit for PCP is 0.2ppb.

  8. Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters.

    Science.gov (United States)

    Herbst, Daniel P

    2016-09-01

    The process of microbubble filtration from blood is complex and highly dependent on the forces of flow and buoyancy. To protect the patient from air emboli, arterial-line filters commonly use a micropore screen, a large volume housing with purpose-built shape, and a purge port to trap, separate, and remove circulating microbubbles. Although it has been proposed that an insufficient buoyancy force renders the purge port ineffective at removing microbubbles smaller than 500 μm, this research attempts to investigate the purge flow of an arterial-line filter to better understand the microbubble removal function in a typical radial filter design. As its primary objective, the study aims to determine the effect of purge-flow rate on bubble capture using air bolus injections from a syringe pump with 22-gauge needle and Doppler ultrasound bubble detection. The measureable bubble size generated in the test circuit ranged between 30 and 500 μm, while purge flow was varied between .1 and .5 L/min for testing. Statistical analysis of the test data was handled using a repeated measures design with significance set at p purge flows yielded higher bubble counts, but the effect of purge-flow rate on bubble capture decreased as bubble size increased. Results also showed that purge flow from the test filter was capable of capturing all bubble sizes being generated over the entire flow range tested, and confirms utility of the purge port in removing microbubbles smaller than 500 μm. By analyzing bubble counts in the purge flow of a typical radial-filter design, this study demonstrates that currently available micropore filter technology is capable of removing the size range of bubbles that commonly pass through modern pump-oxygenator systems and should continue to be considered during extracorporeal circulation as a measure to improve patient safety.

  9. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  10. Application of vena cava intraluminal occlusion technique in minimally invasive isolated tricuspid valve surgery%腔静脉内阻断技术在单纯性三尖瓣微创手术中的应用

    Institute of Scientific and Technical Information of China (English)

    姜兆磊; 朱家全; 梅举; 丁芳宝; 沈赛娥; 黄健兵; 张俊文; 何毅; 蒋连勇

    2013-01-01

    Objective To summarize the experiences of appling vena cava intraluminal occlusion technique in minimally invasive repeated isolated tricuspid valve surgery.Methods Consecutive patients (n=46) with isolated significant late tricuspid regurgitation (TR) after previous cardiac surgery received minimally invasive repeated tricuspid valve surgery in beating heart without cmssclamping ascending aorta from 2002 to 2012.Computed tomography showed that severe adhesions exited in the pericardium and the posterior of the sternum.It was difficult to carry out the conventional median thoracotomy and segregate the vena cava.Cardiopulmonary bypass was initiated by cannulating the right femoral artery for arterial access.A right anterolateral thoracotomy incision was made over the fourth intercostal space.Under transoesophageal echocardiographic guidance,the balloon cannulas were insterted through the surface of the right atrium for the venous drainage both of the superior vena cava (SVC) and the inferior vena cava (IVC) respectively.The balloon of the cannula was inflated to obtain the occlusion of SVC and IVC when the nasopharyngeal temperature was about 32 ℃-33 ℃.After the endovascular occlusion of both the caval veins,the right atrium was opened and the tricuspid valve surgery was performed.Results The tricuspid valve was repaired in 12 patients and replaced in 34 patients.There was not cardiopulmonary bypass accident during the operation.The time of operation was (161±52) min.The time of building cardiopulmonary bypass(CPB) was (55±15) min and the time of CPB was (58±23) min.The postoperative drainage was (275±108) ml,and the postoperative inhospital time was (8±7) days.There was no death in hospital.During the follow-up,2 patients died.One died of pulmonary vascular rupture,and the other died of heart failure.There was no paravalvular leakage occurs in tricuspid valve replacement (TVR).Echocardiography showed that one patient who had tricuspid valve plasty (TVP

  11. Adaptation to a new environment allows cooperators to purge cheaters stochastically.

    Science.gov (United States)

    Waite, Adam James; Shou, Wenying

    2012-11-20

    Cooperation via production of common goods is found in diverse life forms ranging from viruses to social animals. However, natural selection predicts a "tragedy of the commons": Cheaters, benefiting from without producing costly common goods, are more fit than cooperators and should destroy cooperation. In an attempt to discover novel mechanisms of cheater control, we eliminated known ones using a yeast cooperator-cheater system engineered to supply or exploit essential nutrients. Surprisingly, although less fit than cheaters, cooperators quickly dominated a fraction of cocultures. Cooperators isolated from these cocultures were superior to the cheater isolates they had been cocultured with, even though these cheaters were superior to ancestral cooperators. Resequencing and phenotypic analyses revealed that evolved cooperators and cheaters all harbored mutations adaptive to the nutrient-limited cooperative environment, allowing growth at a much lower concentration of nutrient than their ancestors. Even after the initial round of adaptation, evolved cooperators still stochastically dominated cheaters derived from them. We propose the "adaptive race" model: If during adaptation to an environment, the fitness gain of cooperators exceeds that of cheaters by at least the fitness cost of cooperation, the tragedy of the commons can be averted. Although cooperators and cheaters sample from the same pool of adaptive mutations, this symmetry is soon broken: The best cooperators purge cheaters and continue to grow, whereas the best cheaters cause rapid self-extinction. We speculate that adaptation to changing environments may contribute to the persistence of cooperative systems before the appearance of more sophisticated mechanisms of cheater control.

  12. Purge Monitoring Technology for Gaseous Helium (GHe) Conservation

    Science.gov (United States)

    Dickey, Jonathan; Lansaw, John

    2010-01-01

    John C. Stennis Space Center provides rocket engine propulsion testing for the NASA space programs. Since the development of the Space Shuttle, every Space Shuttle Main Engine (SSME) has gone through acceptance testing before going to Kennedy Space Center for integration into the Space Shuttle. The SSME is a large cryogenic rocket engine that used Liquid Oxygen (LO2) and Liquid Hydrogen (LH2) as propellants. Due to the extremely cold cryogenic conditions of this environment, an inert gas, helium, is used as a purge for the engine and propellant lines since it can be used without freezing in the cryogenic environment. As NASA moves forward with the development of the new ARES V launch system, the main engines as well as the upper stage engine will use cryogenic propellants and will require gaseous helium during the development testing of each of these engines. The main engine for the ARES V will be similar in size to the SSME.

  13. Does haplodiploidy purge inbreeding depression in rotifer populations?

    Directory of Open Access Journals (Sweden)

    Ana M Tortajada

    Full Text Available BACKGROUND: Inbreeding depression is an important evolutionary factor, particularly when new habitats are colonized by few individuals. Then, inbreeding depression by drift could favour the establishment of later immigrants because their hybrid offspring would enjoy higher fitness. Rotifers are the only major zooplanktonic group where information on inbreeding depression is still critically scarce, despite the fact that in cyclical parthenogenetic rotifers males are haploid and could purge deleterious recessive alleles, thereby decreasing inbreeding depression. METHODOLOGY/PRINCIPAL FINDINGS: We studied the effects of inbreeding in two populations of the cyclical parthenogenetic rotifer Brachionus plicatilis. For each population, we compared both the parental fertilization proportion and F1 fitness components from intraclonal (selfed and interclonal (outcrossed crosses. The parental fertilization proportion was similar for both types of crosses, suggesting that there is no mechanism to avoid selfing. In the F1 generation of both populations, we found evidence of inbreeding depression for the fitness components associated with asexual reproduction; whereas inbreeding depression was only found for one of the two sexual reproduction fitness components measured. CONCLUSIONS/SIGNIFICANCE: Our results show that rotifers, like other major zooplanktonic groups, can be affected by inbreeding depression in different stages of their life cycle. These results suggest that haplodiploidy does not purge efficiently deleterious recessive alleles. The inbreeding depression detected here has important implications when a rotifer population is founded and intraclonal crossing is likely to occur. Thus, during the foundation of new populations inbreeding depression may provide opportunities for new immigrants, increasing gene flow between populations, and affecting genetic differentiation.

  14. Valve selection in aortic valve endocarditis

    Science.gov (United States)

    Zubrytska, Yana

    2016-01-01

    Aortic prosthetic valve endocarditis (PVE) is a potentially life-threatening disease. Mortality and incidence of infective endocarditis have been reduced in the past 30 years. Medical treatment of aortic PVE may be successful in patients who have a prompt response after antibiotic treatment and who do not have prosthetic dysfunction. In advanced stages, antibiotic therapy alone is insufficient to control the disease, and surgical intervention is necessary. Surgical treatment may be lifesaving, but it is still associated with considerable morbidity and mortality. The aim of surgery is to perform a radical excision of all infected and necrotic tissue, reconstruction of the left ventricle outflow tract, and replacement of the aortic valve. There is no unanimous consensus on which is the optimal prosthesis to implant in this context, and several surgical techniques have been suggested. We aim to analyze the efficacy of the surgical treatment and discuss the issue of valve selection in patients with aortic valve endocarditis.

  15. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2016-03-09

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  16. Exuberant accessory mitral valve tissue with possible true parachute mitral valve: a case report

    Directory of Open Access Journals (Sweden)

    Nikolic Aleksandra

    2012-09-01

    Full Text Available Abstract Introduction A parachute mitral valve is defined as a unifocal attachment of mitral valve chordae tendineae independent of the number of papillary muscles. Data from the literature suggests that the valve can be distinguished on the basis of morphological features as either a parachute-like asymmetrical mitral valve or a true parachute mitral valve. A parachute-like asymmetrical mitral valve has two papillary muscles; one is elongated and located higher in the left ventricle. A true parachute mitral valve has a single papillary muscle that receives all chordae, as was present in our patient. Patients with parachute mitral valves during childhood have multilevel left-side heart obstructions, with poor outcomes without operative treatment. The finding of a parachute mitral valve in an adult patient is extremely rare, especially as an isolated lesion. In adults, the unifocal attachment of the chordae results in a slightly restricted valve opening and, more frequently, valvular regurgitation. Case presentation A 40-year-old Caucasian female patient was admitted to a primary care physician due to her recent symptoms of heart palpitation and chest discomfort on effort. Transthoracic echocardiography showed chordae tendineae which were elongated and formed an unusual net shape penetrating into left ventricle cavity. The parasternal short axis view of her left ventricle showed a single papillary muscle positioned on one side in the posteromedial commissure receiving all chordae. Her mitral valve orifice was slightly eccentric and the chordae were converting into a single papillary muscle. Mitral regurgitation was present and it was graded as moderate to severe. Her left atrium was enlarged. There were no signs of mitral stenosis or a subvalvular ring. She did not have a bicuspid aortic valve or coarctation of the ascending aorta. The dimensions and systolic function of her left ventricle were normal. Our patient had a normal body habitus

  17. Electronic bidirectional valve circuit prevents crossover distortion and threshold effect

    Science.gov (United States)

    Kernick, A.

    1966-01-01

    Four-terminal network forms a bidirectional valve which will switch or alternate an ac signal without crossover distortion or threshold effect. In this network, an isolated control signal is sufficient for circuit turn-on.

  18. JenaValve.

    Science.gov (United States)

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  19. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  20. THEORETICAL ANALYSIS OF USING AIRFLOW TO PURGE RESIDUAL WATER IN AN INCLINED PIPE

    Institute of Scientific and Technical Information of China (English)

    SHEN Fang(沈芳); YAN Zong-yi(严宗毅); ZHAO Yao-hua(赵耀华); Kiyoshi Horii

    2002-01-01

    A refined theoretical analysis for using the spiral airflow and axial airflow to purge residual water in an inclined pipe was presented. The computations reveal that, in most cases, the spiral flow can purge the residual water in the inclined pipe indeed while the axial flow may induce back flow of the water, just as predicted in the experiments presented by Horii and Zhao et al. In addition, the effects of various initial conditions on water purging were studied in detail for both the spiral and axial flow cases.

  1. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves

    DEFF Research Database (Denmark)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann

    2017-01-01

    AIMS: Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, at smaller sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be frac...

  2. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  3. Mitral valve prolapse.

    Science.gov (United States)

    Gould, L; Gopalaswamy, C

    1984-05-01

    Mitral valve prolapse is a very common condition. It occurs in 4-5% of the population. It may be idiopathic or associated with a number of other conditions. Myxomatous degeneration is the underlying mechanism of mitral valve prolapse. Most patients with mitral valve prolapse have no symptoms. When symptoms do occur, palpitations, chest pain and dyspnea are the major complaints. The midsystolic click occasionally followed by the late systolic murmur are the typical physical findings. The echocardiogram plays a big role in the diagnosis of mitral valve prolapse. The beta blockers are used in the treatment of the symptomatic patient.

  4. Biological heart valves.

    Science.gov (United States)

    Ciubotaru, Anatol; Cebotari, Serghei; Tudorache, Igor; Beckmann, Erik; Hilfiker, Andres; Haverich, Axel

    2013-10-01

    Cardiac valvular pathologies are often caused by rheumatic fever in young adults, atherosclerosis in elderly patients, or by congenital malformation of the heart in children, in effect affecting almost all population ages. Almost 300,000 heart valve operations are performed worldwide annually. Tissue valve prostheses have certain advantages over mechanical valves such as biocompatibility, more physiological hemodynamics, and no need for life-long systemic anticoagulation. However, the major disadvantage of biological valves is related to their durability. Nevertheless, during the last decade, the number of patients undergoing biological, rather than mechanical, valve replacement has increased from half to more than three-quarters for biological implants. Continuous improvement in valve fabrication includes development of new models and shapes, novel methods of tissue treatment, and preservation and implantation techniques. These efforts are focused not only on the improvement of morbidity and mortality of the patients but also on the improvement of their quality of life. Heart valve tissue engineering aims to provide durable, "autologous" valve prostheses. These valves demonstrate adaptive growth, which may avoid the need of repeated operations in growing patients.

  5. A piezoelectrically actuated ball valve

    Science.gov (United States)

    Erwin, L. R.; Schwartz, H. W.; Teitelbaum, B. R.

    1972-01-01

    Bimorph strip composed of two layers of poled piezoelectric ceramic material closes and opens valve. Strip performs like capacitator, allowing initial inrush of current when valve is energized and then only small leakage current flows as valve remains energized.

  6. Purge gas protected transportable pressurized fuel cell modules and their operation in a power plant

    Science.gov (United States)

    Zafred, Paolo R.; Dederer, Jeffrey T.; Gillett, James E.; Basel, Richard A.; Antenucci, Annette B.

    1996-01-01

    A fuel cell generator apparatus and method of its operation involves: passing pressurized oxidant gas, (O) and pressurized fuel gas, (F), into fuel cell modules, (10 and 12), containing fuel cells, where the modules are each enclosed by a module housing (18), surrounded by an axially elongated pressure vessel (64), where there is a purge gas volume, (62), between the module housing and pressure vessel; passing pressurized purge gas, (P), through the purge gas volume, (62), to dilute any unreacted fuel gas from the modules; and passing exhaust gas, (82), and circulated purge gas and any unreacted fuel gas out of the pressure vessel; where the fuel cell generator apparatus is transpatable when the pressure vessel (64) is horizontally disposed, providing a low center of gravity.

  7. Purge and trap method to determine alpha factors of VOC liquid-phase mass transfer coefficients

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A theoretical approach and laboratory practice of determining the alpha factors of volatile organic compound (VOC) liquid-phase mass transfer coefficients are present in this study.Using Purge Trap Concentrator, VOC spiked water samples are purged by high-purity nitrogen in the laboratory, the VOC liquid-phase mass transfer rate constants under the laboratory conditions are then obtained by observing the variation of VOCs purged out of the water with the purge time.The alpha factors of VOC liquid-phase mass transfer coefficients are calculated as the ratios of the liquid-phase mass transfer rate constants in real water samples to their counterparts in pure water under the same experimental conditions. This direct and fast approach is easy to control in the laboratory, and would benefit mutual comparison among researchers, so might be useful for thestudy of VOC mass transfer across the liquid-gas interface.

  8. Validated Test Method 5030C: Purge-and-Trap for Aqueous Samples

    Science.gov (United States)

    This method describes a purge-and-trap procedure for the analysis of volatile organic compoundsin aqueous samples & water miscible liquid samples. It also describes the analysis of high concentration soil and waste sample extracts prepared in Method 5035.

  9. Effect of nitrogen crossover on purging strategy in PEM fuel cell systems

    DEFF Research Database (Denmark)

    Rabbani, Raja Abid; Rokni, Masoud

    2013-01-01

    conditions, making it important to investigate the dynamic performance of the system during transitory conditions. The model developed here is able to predict nitrogen crossover in excellent agreement with the design validation data of the stack. The results show that with pure recirculation, voltage...... levels from rising when compared to a fixed purge interval strategy. This model can be used as a base for control and development of anode purge strategies for automotive fuel cell systems....

  10. Better Fitness in Captive Cuvier’s Gazelle despite Inbreeding Increase: Evidence of Purging?

    OpenAIRE

    Eulalia Moreno; Javier Pérez-González; Juan Carranza; Jordi Moya-Laraño

    2015-01-01

    Captive breeding of endangered species often aims at preserving genetic diversity and to avoid the harmful effects of inbreeding. However, deleterious alleles causing inbreeding depression can be purged when inbreeding persists over several generations. Despite its great importance both for evolutionary biology and for captive breeding programmes, few studies have addressed whether and to which extent purging may occur. Here we undertake a longitudinal study with the largest captive populatio...

  11. Effect of the extent of well purging on laboratory parameters of groundwater samples

    Science.gov (United States)

    Reka Mathe, Agnes; Kohler, Artur; Kovacs, Jozsef

    2017-04-01

    Chemicals reaching groundwater cause water quality deterioration. Reconnaissance and remediation demands high financial and human resources. Groundwater samples are important sources of information. Representativity of these samples is fundamental to decision making. According to relevant literature the way of sampling and the sampling equipment can affect laboratory concentrations measured in samples. Detailed and systematic research on this field is missing from even international literature. Groundwater sampling procedures are regulated worldwide. Regulations describe how to sample a groundwater monitoring well. The most common element in these regulations is well purging prior to sampling. The aim of purging the well is to avoid taking the sample from the stagnant water instead of from formation water. The stagnant water forms inside and around the well because the well casing provides direct contact with the atmosphere, changing the physico-chemical composition of the well water. Sample from the stagnant water is not representative of the formation water. Regulations regarding the extent of the purging are different. Purging is mostly defined as multiply (3-5) well volumes, and/or reaching stabilization of some purged water parameters (pH, specific conductivity, etc.). There are hints for sampling without purging. To define the necessary extent of the purging repeated pumping is conducted, triplicate samples are taken at the beginning of purging, at one, two and three times well volumes and at parameter stabilization. Triplicate samples are the means to account for laboratory errors. The subsurface is not static, the test is repeated 10 times. Up to now three tests were completed.

  12. Regimes of Decomposition of Clathrate in Natural Strata Purged by Methane

    Science.gov (United States)

    Khasanov, M.; Shagapov, V.

    2016-06-01

    The process of decomposition of a methane clathrate in a finite-length stratum initially saturated with methane clathrate and methane, which is purged by warm methane, is studied. The influence of the initial parameters of the stratum and purging conditions on the evolution of methane clathrate temperature and saturation is examined. The existence of solutions is demonstrated, which predict methane clathrate decomposition both on the frontal surface and in the volume zone.

  13. Mitral valve surgery - open

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Mitral Valve Prolapse Browse the Encyclopedia A.D. ...

  14. Blocked Urethral Valves

    Science.gov (United States)

    ... Blocked Urethral Valves Health Issues Listen Español Text Size Email Print Share Blocked Urethral Valves Page Content Article Body Urine leaves the bladder through a tube called the urethra, which in boys passes through the penis. Rarely, small membranes form across the urethra in ...

  15. Shutoff and throttling valve

    Science.gov (United States)

    Hays, L. G.

    1974-01-01

    Leaktight shutoff, precise flow control, and very low pressure drop are incorporated in all-metal valve designed for operation under extreme temperatures. Valve constructed with refractory metal is intended for control of high-temperature liquid cesium, but has applications related to control of high- and low-temperature liquids and gases.

  16. Remote operated valves - the Bolivian approach

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar, O.; Arce, G.; Blanco, E.; Collazos, A.; Chavarria, E. [Transredes S.A., Transporte de Hidrocarburos, La Paz (Bolivia)

    2005-07-01

    For pipeline operators, the Remote Operated Valves (ROV) are tools to isolate pipe segments and contain any potential spill and they are also useful tools to provide data on operating conditions. Projects and articles about the locations and site layouts were developed to install Remote Operated Valves and the criteria for their use; each location has its own environmental, social and logistical particulars. This article describes the approach used to install ROV in Bolivia and the final design installed discussions and lessons learned about the: criteria to define the location, layout equipment installed and shelter and particulars of the location. (author)

  17. [Purging behaviors and nutritional status in anorexia nervosa and bulimia nervosa].

    Science.gov (United States)

    Vaz, F J; García-Herráiz, A; López-Vinuesa, B; Monge, M; Fernández-Gil, M A; Guisado, J A

    2003-01-01

    The aim of the study was to investigate whether the use of purgative methods in patients with eating disorders (anorexia nervosa [AN] and bulimia nervosa [BN]) could be capable of producing changes in the nutritional status of the patients. The group under study was composed of 184 female eating disordered outpatients. One hundred and sixteen patients (63.0%) fulfilled the DSM-IV diagnostic criteria for BN (90 purging type, 26 nonpurging type). Sixty eight patients (37.0%) fulfilled the DSM-IV criteria for the diagnosis of AN (48 restricting type, 20 binging-purging type). The assessment process included anthropometry (body circumferences and skinfold thickness) and body impedance analysis. The two subgroups of AN patients significantly differed from each of the BN subgroups. From a nutritional point of view, some significant differences between the two DSM-IV subtypes of AN existed, but not between the purging type and the nonpurging type of BN. The paper discusses the clinical significance of these findings. An alternative subtypification of AN patients is proposed: 1) restricting type [patients who control their food intake and do not purge]; 2) purging type [patient with true episodes of binging which are followed by purgative behaviors]; and 3) pseudopurging type [patients with subjective binging episodes who use purging methods].

  18. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering.

  19. Anticoagulation for Prosthetic Valves

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Kaneko

    2013-01-01

    Full Text Available Implantation of prosthetic valve requires consideration for anticoagulation. The current guideline recommends warfarin on all mechanical valves. Dabigatran is the new generation anticoagulation medication which is taken orally and does not require frequent monitoring. This drug is approved for treatment for atrial fibrillation and venous thromboembolism, but the latest large trial showed that this drug increases adverse events when used for mechanical valve anticoagulation. On-X valve is the new generation mechanical valve which is considered to require less anticoagulation due to its flow dynamics. The latest study showed that lower anticoagulation level lowers the incidence of bleeding, while the risk of thromboembolism and thrombosis remained the same. Anticoagulation poses dilemma in cases such as pregnancy and major bleeding event. During pregnancy, warfarin can be continued throughout pregnancy and switched to heparin derivative during 6–12 weeks and >36 weeks of gestation. Warfarin can be safely started after 1-2 weeks of discontinuation following major bleeding episode.

  20. Fungal native pulmonary valve endocarditis: facing both medical and surgical challenges.

    Science.gov (United States)

    Bouabdallaoui, Nadia; Demondion, Pierre; Lebreton, Guillaume; Leprince, Pascal

    2017-01-01

    Fungal isolated native pulmonary valve endocarditis is extremely uncommon. Data are scarce and report high mortality and recurrence rates. Recommended management combines both medical and surgical approaches. We report herein a rare case of isolated pulmonary valve endocarditis caused by Candida albicans The patient did not display prior heart disease. Medical management was unsuccessful. Pulmonary valve replacement allowed rapid improvement. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Adaptation to a new environment allows cooperators to purge cheaters stochastically

    Science.gov (United States)

    Waite, Adam James; Shou, Wenying

    2012-01-01

    Cooperation via production of common goods is found in diverse life forms ranging from viruses to social animals. However, natural selection predicts a “tragedy of the commons”: Cheaters, benefiting from without producing costly common goods, are more fit than cooperators and should destroy cooperation. In an attempt to discover novel mechanisms of cheater control, we eliminated known ones using a yeast cooperator–cheater system engineered to supply or exploit essential nutrients. Surprisingly, although less fit than cheaters, cooperators quickly dominated a fraction of cocultures. Cooperators isolated from these cocultures were superior to the cheater isolates they had been cocultured with, even though these cheaters were superior to ancestral cooperators. Resequencing and phenotypic analyses revealed that evolved cooperators and cheaters all harbored mutations adaptive to the nutrient-limited cooperative environment, allowing growth at a much lower concentration of nutrient than their ancestors. Even after the initial round of adaptation, evolved cooperators still stochastically dominated cheaters derived from them. We propose the “adaptive race” model: If during adaptation to an environment, the fitness gain of cooperators exceeds that of cheaters by at least the fitness cost of cooperation, the tragedy of the commons can be averted. Although cooperators and cheaters sample from the same pool of adaptive mutations, this symmetry is soon broken: The best cooperators purge cheaters and continue to grow, whereas the best cheaters cause rapid self-extinction. We speculate that adaptation to changing environments may contribute to the persistence of cooperative systems before the appearance of more sophisticated mechanisms of cheater control. PMID:23091010

  2. Distinguishing Between Risk Factors for Bulimia Nervosa, Binge Eating Disorder, and Purging Disorder.

    Science.gov (United States)

    Allen, Karina L; Byrne, Susan M; Crosby, Ross D

    2015-08-01

    Binge eating disorder and purging disorder have gained recognition as distinct eating disorder diagnoses, but risk factors for these conditions have not yet been established. This study aimed to evaluate a prospective, mediational model of risk for the full range of binge eating and purging eating disorders, with attention to possible diagnostic differences. Specific aims were to determine, first, whether eating, weight and shape concerns at age 14 would mediate the relationship between parent-perceived childhood overweight at age 10 and a binge eating or purging eating disorder between age 15 and 20, and, second, whether this mediational model would differ across bulimia nervosa, binge eating disorder, and purging disorder. Participants (N = 1,160; 51 % female) were drawn from the Western Australian Pregnancy Cohort (Raine) Study, which has followed children from pre-birth to age 20. Eating disorders were assessed via self-report questionnaires when participants were aged 14, 17 and 20. There were 146 participants (82 % female) with a binge eating or purging eating disorder with onset between age 15 and 20 [bulimia nervosa = 81 (86 % female), binge eating disorder = 43 (74 % female), purging disorder = 22 (77 % female)]. Simple mediation analysis with bootstrapping was used to test the hypothesized model of risk, with early adolescent eating, weight and shape concerns positioned as a mediator between parent-perceived childhood overweight and later onset of a binge eating or purging eating disorder. Subsequently, a conditional process model (a moderated mediation model) was specified to determine if model pathways differed significantly by eating disorder diagnosis. In the simple mediation model, there was a significant indirect effect of parent-perceived childhood overweight on risk for a binge eating or purging eating disorder in late adolescence, mediated by eating, weight and shape concerns in early adolescence. In the conditional process model

  3. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  4. A novel surgical strategy for secondary hyperparathyroidism: Purge parathyroidectomy.

    Science.gov (United States)

    Shan, Cheng-Xiang; Qiu, Nian-Cun; Zha, Si-Luo; Liu, Miao-E; Wang, Qiang; Zhu, Pei-Pei; Du, Zhi-Peng; Xia, Chun-Yan; Qiu, Ming; Zhang, Wei

    2017-07-01

    This study was intended to demonstrate the feasibility and efficacy of purge parathyroidectomy (PPTX) for patients with secondary hyperparathyroidism (SHPT). The "seed, environment, and soil" medical hypothesis was first raised, following review of the literatures, to demonstrate the possible causes of persistence or recurrence of SHPT after parathyroidectomy. Subsequently, the novel surgical strategy of PPTX was proposed, which involves comprehensive resection of the fibro-fatty tissues, including visible or invisible parathyroid, within the region surrounded by the thyroid cartilage, bilateral carotid artery sheath, and the brachiocephalic artery. The perioperative information and clinical outcomes of patients who underwent PPTX from June 2016 to December 2016 were analyzed. In total, PPTX was performed safely in nine patients with SHPT from June 2016 to December 2016. The operative time for PPTX ranged from 95 to 135 min, and blood loss ranged from 20 to 40 mL. No patients with perioperative death, bleeding, convulsions, or recurrent laryngeal nerve injury were reported. The preoperative concentration of PTH ranged from 1062 to 2879 pg/mL, and from 12.35 to 72.69 pg/mL on the first day after surgery. In total, 37 parathyroid glands were resected. The postoperative pathologic examination showed that supernumerary or ectopic parathyroid tissues were found within the "non-parathyroid" tissues in three patients. No cases encountered persistence or recurrence of SHPT, or severe hypocalcemia during the follow-up period. PPTX involves comprehensive resection of supernumerary and ectopic parathyroid tissues, which may provide a more permanent means of reducing PTH levels. Copyright © 2017. Published by Elsevier Ltd.

  5. Isolation

    DEFF Research Database (Denmark)

    Agerholm, Frank Juul

    2011-01-01

    Næringsstoffet har i dette nummer sat fokus på ”velvære i vinterkulden”, ”indendørsaktiviteter” og ”fedtafgift”. I klummen vises det, at disse tre fokusområder, der for en umiddelbar betragtning måske nok synes noget uensartede, falder sammen i ét tema: Isolation!......Næringsstoffet har i dette nummer sat fokus på ”velvære i vinterkulden”, ”indendørsaktiviteter” og ”fedtafgift”. I klummen vises det, at disse tre fokusområder, der for en umiddelbar betragtning måske nok synes noget uensartede, falder sammen i ét tema: Isolation!...

  6. Mesofluidic two stage digital valve

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  7. Preparation and analysis of helium purge gas mixture to be used in Tritium Extraction System of LLCB TBM

    Science.gov (United States)

    Gayathri Devi, V.; Yadav, Deepak; Sircar, Amit

    2017-04-01

    Hydrogen isotopes are extracted from the Ceramic Breeder (CB) and liquid Lead Lithium (Pb-Li) breeder of Lead Lithium Ceramic Breeder (LLCB) Test Blanket Module (TBM) with Helium purge gas. 1000 ppm of hydrogen gas is mixed with the purge helium gas to facilitate improved extraction of hydrogen isotopes from the breeder zones by hydrogen swamping reactions [1]. An experimental set up is developed for making up the purge gas mixture with a composition similar to the purge gas composition to be used for extraction of hydrogen isotopes from CB and Pb-Li of LLCB TBM. This is achieved by introducing different ppm levels (1000 - 5000 ppm) of hydrogen in helium gas by flow control mechanism. The analysis of the purge gas mixture is performed using a highly sensitive Gas Chromatography (GC) system. This paper describes the detailed design of the experimental set-up and results for the analysis of different concentrations of hydrogen in helium purge gas.

  8. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European...... countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...

  9. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  10. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...... method that can be used to predict the performance of valves....

  11. A valve disk

    Energy Technology Data Exchange (ETDEWEB)

    Khayrullin, N.A.; Isayev, B.N.; Kruglov, S.A.; Molokanov, Yu.K.; Shchelkunov, V.A.; Shegay, V.R.; Vizhgorodskiy, B.N.

    1982-01-01

    A valve disk is proposed which includes a horizontal bed, on which there are laminar valves arranged in staggered order. To ensure the stable and effective operation of the disk in a broad range of loads by compensating for the direct flow and the partial sectioning of the disk bed, it is equipped with compensating elements installed in openings in the bed and hinged with it. They are made in the form of straight, triangular prisms with ports in the bases. The prisms are installed with the capability of movement relative to the disk bed. The valves are positioned on the upper lateral facets of the compensating elements.

  12. Surgical double valve replacement after transcatheter aortic valve implantation and interventional mitral valve repair.

    Science.gov (United States)

    Wendeborn, Jens; Donndorf, Peter; Westphal, Bernd; Steinhoff, Gustav

    2013-11-01

    Transcatheter aortic valve implantation, as well as interventional mitral valve repair, offer reasonable therapeutic options for high-risk surgical patients. We report a rare case of early post-interventional aortic valve prosthesis migration to the left ventricular outflow tract, with paravalvular leakage and causing severe mitral valve regurgitation. Initial successful interventional mitral valve repair using a clipped edge-to-edge technique revealed, in a subsequent procedure, the recurrence of mitral valve regurgitation leading to progressive heart failure and necessitating subsequent surgical aortic and mitral valve replacement.

  13. Mitral Valve Disease

    Science.gov (United States)

    ... for more information on procedures, news, and pre- & post-operative care. Section Navigation Select Topic Aortic Valve Disease ... is most commonly caused by inflammation from rheumatic fever, a disease that is related to strep infections; ...

  14. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  15. Pulmonary valve stenosis

    Science.gov (United States)

    ... valvuloplasty - pulmonary Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  16. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  17. Mitral Valve Prolapse

    Science.gov (United States)

    ... Kawasaki Disease Long Q-T Syndrome Marfan Syndrome Metabolic Syndrome Mitral Valve Prolapse Myocardial Bridge Myocarditis Obstructive Sleep Apnea Pericarditis Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden ...

  18. Variability in bacteria and virus-like particle abundances during purging of unconfined aquifers.

    Science.gov (United States)

    Roudnew, Ben; Lavery, Trish J; Seymour, Justin R; Jeffries, Thomas C; Mitchell, James G

    2014-01-01

    Standard methodologies for sampling the physicochemical conditions of groundwater recommend purging a bore for three bore volumes to avoid sampling the stagnant water within a bore and instead gain samples representative of the aquifer. However, there are currently no methodological standards addressing the amount of purging required to gain representative biological samples to assess groundwater bacterial and viral abundances. The objective of this study was to examine how bacterial and viral abundances change during the purging of bore volumes. Six bores infiltrating into unconfined aquifers were pumped for five or six bore volumes each and bacteria and virus-like particles (VLPs) were enumerated from each bore volume using flow cytometry. In examination of the individual bores trends in bacterial abundances were observed to increase, decrease, or remain constant with each purged bore volume. Furthermore, triplicates taken at each bore volume indicated substantial variations in VLP and bacterial abundances that are often larger than the differences between bore volumes. This indicates a high level of small scale heterogeneity in microbial community abundance in groundwater samples, and we suggest that this may be an intrinsic feature of bore biology. The heterogeneity observed may be driven by bottom up processes (variability in the distribution of organic and inorganic nutrients), top-down processes (grazing and viral lysis), physical heterogeneities in the bore, or technical artifacts associated with the purging process. We suggest that a more detailed understanding of the ecology underpinning this variability is required to adequately describe the microbiological characteristics of groundwater ecosystems.

  19. The Initial Purging Policies after the 1965 Incident at Lubang Buaya

    Directory of Open Access Journals (Sweden)

    Yosef Djakababa

    2013-01-01

    Full Text Available After the Lubang Buaya incident on 1 October 1965 in which six top Indonesian Army generals and a lieutenant were killed, the Army began to implement a nationwide purging campaign with the assistance of civilian anti-communist groups. Thousands of PKI members, supporters and pro-Sukarno groups/individuals immediately became the target of this purge. For organisational purposes, several purging policies were released and then strictly enforced. The official purging policies that are highlighted in this paper are a series of initial directives that were released within days of the generals’ executions. They do not explicitly translate into orders to kill, but are more of a guideline to help anti-communist officials classify and contain communists and other PKI followers. This article attempts to show how these initial directives evolved and also discusses competing purge policies from non-military sources. The co-existence and overlapping nature of the various directives indicate that a power struggle existed between the anti-communist group led by General Soeharto and the presidium of the Dwikora Cabinet who were loyal to President Soekarno.

  20. Appetite regulatory hormones in women with anorexia nervosa: binge-eating/purging versus restricting type.

    Science.gov (United States)

    Eddy, Kamryn T; Lawson, Elizabeth A; Meade, Christina; Meenaghan, Erinne; Horton, Sarah E; Misra, Madhusmita; Klibanski, Anne; Miller, Karen K

    2015-01-01

    Anorexia nervosa is a psychiatric illness characterized by low weight, disordered eating, and hallmark neuroendocrine dysfunction. Behavioral phenotypes are defined by predominant restriction or bingeing/purging; binge-eating/purging type anorexia nervosa is associated with poorer outcome. The pathophysiology underlying anorexia nervosa types is unknown, but altered hormones, known to be involved in eating behaviors, may play a role. To examine the role of anorexigenic hormones in anorexia nervosa subtypes, we examined serum levels of peptide YY (PYY; total and active [3-36] forms), brain-derived neurotrophic factor (BDNF), and leptin as primary outcomes in women with DSM-5 restricting type anorexia nervosa (n = 50), binge-eating/purging type anorexia nervosa (n = 25), and healthy controls (n = 22). In addition, women completed validated secondary outcome measures of eating disorder psychopathology (Eating Disorder Examination-Questionnaire) and depression and anxiety symptoms (Hamilton Rating Scales for Depression [HDRS] and Anxiety [HARS]). The study samples were collected from May 22, 2004, to February 7, 2012. Mean PYY 3-36 and leptin levels were lower and BDNF levels higher in binge-eating/purging type anorexia nervosa than in restricting type anorexia nervosa (all P values anorexia nervosa types were significant (P anorexia nervosa, the anorexigenic hormones PYY, BDNF, and leptin are differentially regulated between the restricting and binge/purge types. Whether these hormone pathways play etiologic roles with regard to anorexia nervosa behavioral types or are compensatory merits further study. © Copyright 2015 Physicians Postgraduate Press, Inc.

  1. Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Richard, James A. (Inventor)

    2017-01-01

    A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.

  2. Local area water removal analysis of a proton exchange membrane fuel cell under gas purge conditions.

    Science.gov (United States)

    Lee, Chi-Yuan; Lee, Yu-Ming; Lee, Shuo-Jen

    2012-01-01

    In this study, local area water content distribution under various gas purging conditions are experimentally analyzed for the first time. The local high frequency resistance (HFR) is measured using novel micro sensors. The results reveal that the liquid water removal rate in a membrane electrode assembly (MEA) is non-uniform. In the under-the-channel area, the removal of liquid water is governed by both convective and diffusive flux of the through-plane drying. Thus, almost all of the liquid water is removed within 30 s of purging with gas. However, liquid water that is stored in the under-the-rib area is not easy to remove during 1 min of gas purging. Therefore, the re-hydration of the membrane by internal diffusive flux is faster than that in the under-the-channel area. Consequently, local fuel starvation and membrane degradation can degrade the performance of a fuel cell that is started from cold.

  3. Purging using the Heimlich maneuver among children and adolescents with eating disorders.

    Science.gov (United States)

    Boachie, Ahmed; Kusi Appiah, Edigna; Jubin, Michelle; Jasper, Karin

    2015-09-01

    This case report describes five independent cases of children and adolescents assessed for eating disorders who disclosed using the Heimlich maneuver as a purging technique. The maneuver is meant to be used only in life or death situations, likely once or less in any person's lifetime. A child or adolescent with an eating disorder may be using it to self-induce vomiting on a daily basis, increasing the risk of complications, including potential damage to major organs of the body. Asking patients who purge to elaborate on the methods with which they purge can provide clinicians with fuller information, improving their ability to select appropriate medical tests and interventions. Thorough investigations of physical complaints during the patient assessment may be warranted, including examining patients for possible rib fractures, hemorrhages, perforations of the hollow viscous, and other forms of blunt abdominal traumas.

  4. Thinness and eating expectancies predict subsequent binge-eating and purging behavior among adolescent girls.

    Science.gov (United States)

    Smith, Gregory T; Simmons, Jean R; Flory, Kate; Annus, Agnes M; Hill, Kelly K

    2007-02-01

    One's expectancies for reinforcement from eating or from thinness are thought to represent summaries of one's eating-related learning history and to thus influence the development of binge-eating and purging behavior. In a 3-year longitudinal study, the authors tested this hypothesis and the hypothesis that binge eating also influences subsequent expectancy development. The authors used trajectory analysis to identify groups of middle school girls who followed different trajectories of binge eating, purging, eating expectancies, and thinness expectancies. Initial eating and thinness reinforcement expectancies identified girls whose binge eating and purging increased during middle school, and expectancies differentiated girls who began these problem behaviors from girls who did not. Initial binge-eating scores differentiated among eating expectancy developmental trajectories. The onset of most behaviors can be understood in terms of learned expectancies for reinforcement from these behaviors. The same model can be applied to the risk for eating disorders.

  5. Effect of the purging gas on properties of Ti stabilized AISI 321 stainless steel TIG welds

    Energy Technology Data Exchange (ETDEWEB)

    Taban, Emel; Kaluc, Erdinc; Aykan, T. Serkan [Kocaeli Univ. (Turkey). Dept. of Mechanical Engineering

    2014-07-01

    Gas purging is necessary to provide a high quality of stainless steel pipe welding in order to prevent oxidation of the weld zone inside the pipe. AISI 321 stabilized austenitic stainless steel pipes commonly preferred in refinery applications have been welded by the TIG welding process both with and without the use of purging gas. As purging gases, Ar, N{sub 2}, Ar + N{sub 2} and N{sub 2} + 10% H{sub 2} were used, respectively. The aim of this investigation is to detect the effect of purging gas on the weld joint properties such as microstructure, corrosion, strength and impact toughness. Macro sections and microstructures of the welds were investigated. Chemical composition analysis to obtain the nitrogen, oxygen and hydrogen content of the weld root was done by Leco analysis. Ferrite content of the beads including root and cap passes were measured by a ferritscope. Vickers hardness (HV10) values were obtained. Intergranular and pitting corrosion tests were applied to determine the corrosion resistance of all welds. Type of the purging gas affected pitting corrosion properties as well as the ferrite content and nitrogen, oxygen and hydrogen contents at the roots of the welds. Any hot cracking problems are not predicted as the weld still solidifies with ferrite in the primary phase as confirmed by microstructural and ferrite content analysis. Mechanical testing showed no significant change according to the purge gas. AISI 321 steel and 347 consumable compositions would permit use of nitrogen rich gases for root shielding without a risk of hot cracking.

  6. Understanding and predicting the fitness decline of shrunk populations: inbreeding, purging, mutation, and standard selection.

    Science.gov (United States)

    García-Dorado, Aurora

    2012-04-01

    The joint consequences of inbreeding, natural selection, and deleterious mutation on mean fitness after population shrinkage are of great importance in evolution and can be critical to the conservation of endangered populations. I present simple analytical equations that predict these consequences, improving and extending a previous heuristic treatment. Purge is defined as the "extra" selection induced by inbreeding, due to the "extra" fitness disadvantage (2d) of homozygotes for (partially) recessive deleterious alleles. Its effect is accounted for by using, instead of the classical inbreeding coefficient f, a purged inbreeding coefficient g that is weighed by the reduction of the frequency of deleterious alleles caused by purging. When the effective size of a large population is reduced to a smaller stable value N (with Nd ≥ 1), the purged inbreeding coefficient after t generations can be predicted as g(t) ≈ [(1 - 1/2N) g(t)(-1) + 1/2N](1 - 2d f(t)(-1)), showing how purging acts upon previously accumulated inbreeding and how its efficiency increases with N. This implies an early fitness decay, followed by some recovery. During this process, the inbreeding depression rate shifts from its ancestral value (δ) to that of the mutation-selection-drift balance corresponding to N (δ*), and standard selection cancels out the inbreeding depression ascribed to δ*. Therefore, purge and inbreeding operate only upon the remaining δ - δ*. The method is applied to the conservation strategy in which family contributions to the breeding pool are equal and is extended to make use of genealogical information. All these predictions are checked using computer simulation.

  7. Implantation of the CoreValve percutaneous aortic valve.

    Science.gov (United States)

    Lamarche, Yoan; Cartier, Raymond; Denault, André Y; Basmadjian, Arsène; Berry, Colin; Laborde, Jean-Claude; Bonan, Raoul

    2007-01-01

    Surgical aortic valve replacement is the only recommended treatment for significant aortic valve stenosis. Percutaneous aortic valve replacement appears to be a novel option for high-risk patients. We report the implantation of the ReValving system (CoreValve, Paris, France) in a 64-year-old woman who was refused aortic valve replacement surgery for critical aortic stenosis and left ventricular dysfunction because of severe pulmonary fibrosis. After anesthesia, the patient was put on femorofemoral cardiopulmonary bypass, and underwent a balloon valvuloplasty with subsequent retrograde aortic valve replacement by the ReValving system. Transesophageal echocardiographic monitoring of the patient's hemodynamics showed immediate improvements of the valvular area and left ventricular ejection fraction and only traces of paravalvular leaks. The patient was easily weaned from ventilation and resumed activity soon after the surgery. A multidisciplinary approach is presently necessary to offer a reliable and safe procedure.

  8. Colonic diverticular bleeding: urgent colonoscopy without purging and endoscopic treatment with epinephrine and hemoclips

    Directory of Open Access Journals (Sweden)

    Ignacio Couto-Worner

    2013-09-01

    Full Text Available Diverticular disease is the most frequent cause of lower gastrointestinal bleeding. Most of the times, bleeding stops without any intervention but in 10-20 % of the cases it is necessary to treat the hemorrhage. Several modalities of endoscopic treatment have been described after purging the colon. We present five cases of severe diverticular bleeding treated with injection of epinephrine and hemoclips. All the colonoscopies were performed without purging of the colon in an emergency setting, with correct visualization of the point of bleeding. Patients recovered well avoiding other aggressive procedures such as angiography or surgery.

  9. Development and validation of purged thermal protection systems for liquid hydrogen fuel tanks of hypersonic vehicles

    Science.gov (United States)

    Helenbrook, R. D.; Colt, J. Z.

    1977-01-01

    An economical, lightweight, safe, efficient, reliable, and reusable insulation system was developed for hypersonic cruise vehicle hydrogen fuel tanks. Results indicate that, a nitrogen purged, layered insulation system with nonpermeable closed-cell insulation next to the cryogenic tank and a high service temperature fibrous insulation surrounding it, is potentially an attractive solution to the insulation problem. For the postulated hypersonic flight the average unit weight of the purged insulation system (including insulation, condensate and fuel boil off) is 6.31 kg/sq m (1.29 psf). Limited cyclic tests of large specimens of closed cell polymethacrylimide foam indicate it will withstand the expected thermal cycle.

  10. Methods for determining atypical gate valve thrust requirements

    Energy Technology Data Exchange (ETDEWEB)

    Steele, R. Jr.; Watkins, J.C.; DeWall, K.G. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1995-04-01

    Evaluating the performance of rising stem, wedge type, gate valves used in nuclear power plant is not a problem when the valves can be design-basis tested and their operability margins determined diagnostically. The problem occurs when they cannot be tested because of plant system limitations or when they can be tested only at some less-than-design-basis condition. To evaluate the performance of these valves requires various analytical and/or extrapolation methods by which the design-basis stem thrust requirement can be determined. This has been typically accomplished with valve stem thrust models used to calculate the requirements or by extrapolating the results from a less-than-design-basis test. The stem thrust models used by the nuclear industry to determine the opening or closing stem thrust requirements for these gate valves have generally assumed that the highest load the valve experiences during closure (but before seating) is at flow isolation and during unwedging or before flow initiation in the opening direction. However, during full-scale valve testing conducted for the USNRC, several of the valves produced stem thrust histories that showed peak closing stem forces occurring before flow isolation in the closing direction and after flow initiation in the opening direction. All of the valves that exhibited this behavior in the closing direction also showed signs of internal damage. Initially, we dismissed the early peak in the closing stem thrust requirement as damage-induced and labeled it nonpredictable behavior. Opening responses were not a priority in our early research, so that phenomenon was set aside for later evaluation.

  11. [Technologies for cardiac valve prostheses].

    Science.gov (United States)

    Nakano, Kiyoharu

    2009-07-01

    To show the technological development of cardiac valve prostheses, a historical review of both mechanical and biological valve prostheses and a current overview of modern cardiac valve devices are provided. Scince the 1st implantation of Starr-Edwards ball valve in 1960, both mechanical and biological valve prostheses have advanced. The valve design, the material of the leaflet and the hausing of mechanical prostheses have improved. Currently, the majority of the mechanical prostheses are bileaflet tilting disc valves made of pyrolytic carbon, which is antithromboembolic. However, anticoagulation therapy with warfarin is still required. As for the bioprostheses, although the fixation and anti-mineralization methods of the tissues improved, the durability of these valves is still limited. For the material of the current biological valves, the porcine aortic valve or bovine pericardium are used. The tissues are fixed by non-pressure or low-pressure method in glutaraldehyde solution. A stented and non-stented valves are available. Epoch-making events in this field are the implantation of new bioprosthetic valves using tissue engineering methods and the development of the transcatheter valve replacement therapies.

  12. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen;

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry.......Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  13. KPT系列吹扫装置的典型应用%Typical Applications of the KPT Series Purge Device

    Institute of Scientific and Technical Information of China (English)

    陈晶

    2012-01-01

    针对KPT系列吹扫装置原理进行了深入分析,并对吹扫装置的几种应用进行阐述。%More in-depth analysis of device principle for the KPT series purge is carried out and several purge applications are described in detail.

  14. Mitral Valve Aneurysm: A Rare Complication of Aortic Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    A Moaref

    2008-11-01

    Full Text Available A 20-year-old intravenous drug abuser man, refered to our hospital with dyspnea and orthopnea. Tranesophagealechocardiography revealed severe aortic regurgitation, healed vegetation of aortic valve and an aneurysm of theanterior leaflet of the mitral valve. The patient was discharged after aortic valve replacement and mitral valverepair.

  15. Research on Valve Body Design of Large Bore Sodium Valve

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Large bore sodium valve is one kind of key equipments of China Demonstration Fast Reactor (CDFR). It is installed in the pipeline before and behind SG units as a locking mechanism. Valve body which is used to bear pressure is the core of sodium valve design.

  16. Transcatheter Aortic Heart Valve Thrombosis

    DEFF Research Database (Denmark)

    Hansson, Nicolaj C; Grove, Erik L; Andersen, Henning R;

    2016-01-01

    BACKGROUND: There is increasing focus on transcatheter heart valve (THV) thrombosis. However, there are limited data on incidence, clinical implications and predisposing factors of THV thrombosis following transcatheter aortic valve replacement (TAVR). OBJECTIVES: We assessed the incidence...

  17. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  18. Nasal valve surgery.

    Science.gov (United States)

    Apaydin, Fazil

    2011-04-01

    Nasal obstruction can be due to internal and external valve problems that can be seen before and after rhinoplasty. The main scope of this article is to concentrate on surgical solutions to these problems. To overcome nasal obstruction at the internal valve, spreader grafts, spreader flaps, upper lateral splay graft, butterfly graft, flaring suture, M-plasty, Z-plasty, and suspension sutures have been described. The management of the external valve problems is possible by using lateral crural dissection and repositioning, lateral crural strut grafts, alar battens, lateral crural turn-in flap, alar rim grafts, and various other methods. It is not easy to decide which techniques would work best in every case. After a thorough examination and analysis, the underlying cause of the nasal obstruction can be understood, and one or multiple procedures can be chosen according to each individual problem.

  19. Percutaneous mitral valve repair.

    Science.gov (United States)

    Gillinov, A Marc; Liddicoat, John R

    2006-01-01

    Surgical mitral valve repair is the procedure of choice to treat mitral regurgitation of all etiologies. Whereas annuloplasty is the cornerstone of mitral valve repair, a variety of other surgical techniques are utilized to correct dysfunction of the leaflets and subvalvular apparatus; in most cases, surgical repair entails application of multiple repair techniques in each patient. Preclinical studies and early human experience have demonstrated that some of these surgical repair techniques can be performed using percutaneous approaches. Specifically, there has been great progress in the development of novel technology to facilitate percutaneous annuloplasty and percutaneous edge-to-edge repair. The objectives of this report were to (1) discuss the surgical foundations for these percutaneous approaches; (2) review device design and experimental and clinical results of percutaneous valve repair; and (3) address future directions, including the key challenges of patient selection and clinical trial design.

  20. ORGANIC TRICUSPID VALVE REPAIR WITH AUTOLOGOUS GLUTARALDEHYDE FIXED PERICARDIAL PATCH : A SINGLE CENTER RESULTS

    Directory of Open Access Journals (Sweden)

    Murtaza A

    2015-10-01

    Full Text Available AIM AND OBJECTIVE: The aim of this study was to determine the effectiveness and results of repair of Organic Tricuspid Valve disease. INTRODUCTION : since tricuspid valve disease most often found in association with other valve disease. Isolated tricuspid valve disease is ra re. Pattern of involvement of tricuspid valve disease shows functional (75% and primary (organic in (25%. Surgical repair of organic tricuspid valve disease often fails because of abnormal valve. This usually leads to limited options. This study examine s our experience of tricuspid valve repair with autologous pericardium for organic tricuspid valve disease. MATERIAL AND METHODS : From Jan 2014 to May 2015, 22 patients underwent repairs for organic tricuspid valve disease. The patient aged 15 to 65 years and all were in New York Heart Association (NYHA class of III or IV. All patients presented with severe tricuspid disease coexisting with other cardiac pathology, usually left - sided heart valve disease. Repair techniques included Commisurotomy, division o f secondary chordae, Glutaraldehyde treated autologous pericardial patch augmentation of tricuspid valve leaflets, anterior papillary muscle advancement etc with or without ring/suture annuloplasty. Follow - up duration was 3 to 18 months. RESULTS : No deaths or late reoperations occurred. All patients demonstrated clinical improvements on follow up. Echocardiographic studies before hospital discharge showed less than mild tricuspid regurgitation in all patients except one. CONCLUSIONS : Large majorit y of organic tricuspid valve regurgitation is repairable with acceptable early results. Tricuspid stenosis and mixed tricuspid valve disease are more challenging. In the latter group, it is a judgment call whether to accept a suboptimal result or replace t he valve

  1. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  2. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...... resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel....

  3. Pulsatile prosthetic valve flows.

    Science.gov (United States)

    Phillips, W M; Snyder, A; Alchas, P; Rosenberg, G; Pierce, W S

    1980-01-01

    The laser Doppler system has been established as a useful tool for eliciting the properties of simulated cardiovascular flows, and thus for comparative studies of flow properties of prosthetic valves. Significant differences among valve types and between models of one type have been documented. The complex variations of velocity profiles with time show that comparisons must be made for unsteady pulsatile rather than steady flow, despite the volume and complexity of the data required. Future studies will include methods of compacting the data presentation and improving the details of the experimental stimulation.

  4. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1990-12-31

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele`s pivot. The Schiele`s pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele`s pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele`s pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  5. Transcatheter Valve-in-Valve: A Cautionary Tale.

    Science.gov (United States)

    Luc, Jessica G Y; Shanks, Miriam; Tyrrell, Benjamin D; Welsh, Robert C; Butler, Craig R; Meyer, Steven R

    2016-09-01

    Transcatheter aortic valve replacement (TAVR) by valve-in-valve (VIV) implantation is an alternative treatment for high-risk patients with a degenerating aortic bioprosthesis. We present a case of transapical TAVR VIV with a 29-mm Edwards SAPIEN XT (ESV) (Edwards Lifesciences, Irvine, CA) into a 29-mm Medtronic Freestyle stentless bioprosthesis (Medtronic Inc, Minneapolis, MN) in which unanticipated dilatation of the Freestyle bioprosthesis resulted in intraprocedural embolization of the TAVR valve, necessitating urgent conversion to a conventional surgical aortic valve replacement (AVR). Our experience suggests that TAVR VIV with the 29-mm ESV in the setting of a degenerated 29-mm Freestyle stentless bioprosthesis must be undertaken with caution.

  6. Assessment of methylprednisolone purging efficacy on Daudi burkitt lymphoma cells from normal bone marrow.

    Science.gov (United States)

    Janakiraman, N; Niewenhuis, L M

    1991-01-01

    Studies on normal bone marrow and Daudi Burkitt lymphoma cells were performed to determine the efficacy of selective, in vitro chemopurging with methylprednisolone (MP). We found that MP reduces the number of lymphoma cells without significant damage to bone marrow cells. This information is important because we need to improve the existing in vitro purging regimens used to cleanse autologous marrows of metastatic disease before transplantation into cancer patients who have received high-dose chemotherapy. Normal human bone marrow (NBM) and Daudi lymphoma cells were treated in parallel with various purging regimens, NBM death was evaluated using soft-agar culture, while Daudi cell death was evaluated using one-week liquid culture. A protocol of 2.0 mg/mL of MP for four hours demonstrated optimal selectivity. When treatment was followed by cryopreservation, a 1.7 log purge of Daudi cells was increased to 2.3 logs while preserving 36% of committed NBM precursors. We repeated these experiments on a simulated contaminated marrow to model closely the mixture of normal and malignant cells found in advanced, metastatic disease. We evaluated this mixed system by flow cytometric immunoanalysis using the two-color CD10/CD20 markers to detect residual, viable Daudi cells. Our initial results were reproducible in this mixed-cell system, further supporting the evidence for effective in vitro purging of bone marrow using MP.

  7. On the Consequences of Purging and Linkage on Fitness and Genetic Diversity

    Directory of Open Access Journals (Sweden)

    Diego Bersabé

    2016-01-01

    Full Text Available Using computer simulation we explore the consequences of linkage on the inbreeding load of an equilibrium population, and on the efficiency of purging and the loss of genetic diversity after a reduction in population size. We find that linkage tends to cause increased inbreeding load due to the build up of coupling groups of (partially recessive deleterious alleles. It also induces associative overdominance at neutral sites but rarely causes increased neutral genetic diversity in equilibrium populations. After a reduction in population size, linkage can cause some delay both for the expression of the inbreeding load and the corresponding purging. However, reasonable predictions can be obtained for the evolution of fitness under inbreeding and purging by using empirical estimates of the inbreeding depression rate. Purging selection against homozygotes for deleterious alleles affects the population’s pedigree. Furthermore, it can slow the loss of genetic diversity compared to that expected from the variance of gametic contributions to the breeding group and even from pedigree inbreeding. Under some conditions, this can lead to a smaller loss of genetic diversity, even below that expected from population size in the absence of selection.

  8. Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids

    Science.gov (United States)

    Larson, I. Lauren; Chiles, Marion M.; Miller, V. Clint

    1993-01-01

    Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

  9. The ex vivo purge of cancer cells using oncolytic viruses: recent advances and clinical implications

    Directory of Open Access Journals (Sweden)

    Tsang JJ

    2015-01-01

    Full Text Available Jovian J Tsang,1,2 Harold L Atkins2,3 1Department of Biochemistry, University of Ottawa, 2Cancer Therapeutics, Ottawa Hospital Research Institute, 3Blood and Marrow Transplant Program, The Ottawa Hospital, Ottawa, ON, Canada Abstract: Hematological malignancies are treated with intensive high-dose chemotherapy, with or without radiation. This is followed by hematopoietic stem cell (HSC transplantation (HSCT to rescue or reconstitute hematopoiesis damaged by the anticancer therapy. Autologous HSC grafts may contain cancer cells and purging could further improve treatment outcomes. Similarly, allogeneic HSCT may be improved by selectively purging alloreactive effector cells from the graft rather than wholesale immune cell depletion. Viral agents that selectively replicate in specific cell populations are being studied in experimental models of cancer and immunological diseases and have potential applications in the context of HSC graft engineering. This review describes preclinical studies involving oncolytic virus strains of adenovirus, herpes simplex virus type 1, myxoma virus, and reovirus as ex vivo purging agents for HSC grafts, as well as in vitro and in vivo experimental studies using oncolytic coxsackievirus, measles virus, parvovirus, vaccinia virus, and vesicular stomatitis virus to eradicate hematopoietic malignancies. Alternative ex vivo oncolytic virus strategies are also outlined that aim to reduce the risk of relapse following autologous HSCT and mitigate morbidity and mortality due to graft-versus-host disease in allogeneic HSCT. Keywords: hematopoietic stem cells, oncolytic virus, hematopoietic stem cell transplantation, stem cell graft purging, hematopoietic malignancy, graft vs host disease

  10. EVALUATION OF VAPOR EQUILIBRATION AND IMPACT OF PURGE VOLUME ON SOIL-GAS SAMPLING RESULTS

    Science.gov (United States)

    Sequential sampling was utilized at the Raymark Superfund site to evaluate attainment of vapor equilibration and the impact of purge volume on soil-gas sample results. A simple mass-balance equation indicates that removal of three to five internal volumes of a sample system shou...

  11. Rituximab purging and/or maintenance in patients undergoing autologous transplantation for relapsed follicular lymphoma

    DEFF Research Database (Denmark)

    Pettengell, Ruth; Schmitz, Norbert; Gisselbrecht, Christian

    2013-01-01

    The objective of this randomized trial was to assess the efficacy and safety of rituximab as in vivo purging before transplantation and as maintenance treatment immediately after high-dose chemotherapy and autologous stem-cell transplantation (HDC-ASCT) in patients with relapsed follicular lympho...

  12. Prosthetic valve thrombosis in a patient with mitral valve replacement.

    Science.gov (United States)

    Bilal, Muhammad; Khan, Muhammad Shahzeb; Haseeb, Abdul; Khan, Abdul Bari

    2015-07-01

    Prosthetic valve thrombosis within one year after mitral valve replacement is rarely seen in patients on warfarin therapy and without any risk factor. Here, we describe a case of a 39-year- old female, who presented with dyspnoea and shortness of breath 11 months after mitral valve replacement. The echocardiogram revealed severe valvular stenosis due to presence of clots on the mitral valve and restricted motion of the mitral leaflets. As a result of deterioration of general condition and haemodynamic un-stability, plan was made to re-operate for her valve replacement surgery. This case report highlights the diagnosis, prevention and management of patients with prosthetic valve thrombosis following mitral valve replacement.

  13. Distortion of the CoreValve during transcatheter aortic valve-in-valve implantation due to valve dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Souteyrand, Geraud, E-mail: gsouteyrand@chu-clermontferrand.fr [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Wilczek, Krzysztof [Department of Cardiology, Medical University of Silesia, Silesian Centre for Herat Diseases, Zabrze (Poland); Innorta, Andrea; Camilleri, Lionel [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Chodor, Piotr [Department of Cardiology, Medical University of Silesia, Silesian Centre for Herat Diseases, Zabrze (Poland); Lusson, Jean-René; Motreff, Pascal [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Laborde, Jean-Claude [St. George' s Hospital, London (United Kingdom); Chabrot, Pascal; Durel, Nicolas [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France)

    2013-09-15

    Nowadays transcatheter aortic valve implantation (TAVI) is an accepted alternative to surgical aortic valve replacement for high-risk patients (pts). Successful TAVI procedures for failed aortic surgical bioprosthesis (TAV-in-SAV) have already been reported. In the presented two cases of TAV-in-SAV implantation a strut distortion of the stent was revealed on angiographic imaging and confirmed on control CT scan. In both procedures, a dislocation of the medtronic core valve (MCV) prosthesis during implantation led to valve retrieval, with a necessity of reloading it in the 18F introducer before subsequent implantation of the same valve in correct position.

  14. Eating Patterns in Youth with Restricting and Binge Eating/Purging Type Anorexia Nervosa

    Science.gov (United States)

    Elran-Barak, Roni; Accurso, Erin C.; Goldschmidt, Andrea B.; Sztainer, Maya; Byrne, Catherine; Le Grange, Daniel

    2015-01-01

    Objective To describe eating patterns in youth with restricting and binge/purge type anorexia nervosa (AN) and to examine whether eating patterns are associated with binge eating or purging behaviors. Method Participants included 160 children and adolescents (M=15.14±2.17 years) evaluated at The University of Chicago Eating Disorders Program who met criteria for DSM-5 restrictive type AN (AN-R; 75%; n=120) or binge eating/purging type AN (AN-BE/P; 25%; n=40). All participants completed the Eating Disorder Examination (EDE) upon initial evaluation. Results Youth with AN-R and AN-BE/P differed in their eating patterns, such that youth with AN-R consumed meals and snacks more regularly relative to youth with AN-BE/P. Among youth with AN-BE/P, skipping dinner was associated with a greater number of binge eating episodes (r=−.379, p<0.05), while skipping breakfast was associated with a greater number of purging episodes (r=−.309, p<0.05). Discussion Youth with AN-R generally follow a regular meal schedule, but are likely consuming insufficient amounts of food across meals and snacks. In contrast, youth with AN-BE/P tend to have more irregular eating patterns, which may play a role in binge eating and purging behaviors. Adults monitoring of meals may be beneficial for youth with AN, and particularly those with AN-BE/P who engage in irregular eating patterns. PMID:24777645

  15. Better Fitness in Captive Cuvier's Gazelle despite Inbreeding Increase: Evidence of Purging?

    Science.gov (United States)

    Moreno, Eulalia; Pérez-González, Javier; Carranza, Juan; Moya-Laraño, Jordi

    2015-01-01

    Captive breeding of endangered species often aims at preserving genetic diversity and to avoid the harmful effects of inbreeding. However, deleterious alleles causing inbreeding depression can be purged when inbreeding persists over several generations. Despite its great importance both for evolutionary biology and for captive breeding programmes, few studies have addressed whether and to which extent purging may occur. Here we undertake a longitudinal study with the largest captive population of Cuvier's gazelle managed under a European Endangered Species Programme since 1975. Previous results in this population have shown that highly inbred mothers tend to produce more daughters, and this fact was used in 2006 to reach a more appropriate sex-ratio in this polygynous species by changing the pairing strategy (i.e., pairing some inbred females instead of keeping them as surplus individuals in the population). Here, by using studbook data we explore whether purging has occurred in the population by investigating whether after the change in pairing strategy a) inbreeding and homozygosity increased at the population level, b) fitness (survival) increased, and c) the relationship between inbreeding and juvenile survival, was positive. Consistent with the existence of purging, we found an increase in inbreeding coefficients, homozygosity and juvenile survival. In addition, we showed that in the course of the breeding programme the relationship between inbreeding and juvenile survival was not uniform but rather changed over time: it was negative in the early years, flat in the middle years and positive after the change in pairing strategy. We highlight that by allowing inbred individuals to mate in captive stocks we may favour sex-ratio bias towards females, a desirable managing strategy to reduce the surplus of males that force most zoos to use ethical culling and euthanizing management tools. We discuss these possibilities but also acknowledge that many other effects

  16. Better Fitness in Captive Cuvier's Gazelle despite Inbreeding Increase: Evidence of Purging?

    Directory of Open Access Journals (Sweden)

    Eulalia Moreno

    Full Text Available Captive breeding of endangered species often aims at preserving genetic diversity and to avoid the harmful effects of inbreeding. However, deleterious alleles causing inbreeding depression can be purged when inbreeding persists over several generations. Despite its great importance both for evolutionary biology and for captive breeding programmes, few studies have addressed whether and to which extent purging may occur. Here we undertake a longitudinal study with the largest captive population of Cuvier's gazelle managed under a European Endangered Species Programme since 1975. Previous results in this population have shown that highly inbred mothers tend to produce more daughters, and this fact was used in 2006 to reach a more appropriate sex-ratio in this polygynous species by changing the pairing strategy (i.e., pairing some inbred females instead of keeping them as surplus individuals in the population. Here, by using studbook data we explore whether purging has occurred in the population by investigating whether after the change in pairing strategy a inbreeding and homozygosity increased at the population level, b fitness (survival increased, and c the relationship between inbreeding and juvenile survival, was positive. Consistent with the existence of purging, we found an increase in inbreeding coefficients, homozygosity and juvenile survival. In addition, we showed that in the course of the breeding programme the relationship between inbreeding and juvenile survival was not uniform but rather changed over time: it was negative in the early years, flat in the middle years and positive after the change in pairing strategy. We highlight that by allowing inbred individuals to mate in captive stocks we may favour sex-ratio bias towards females, a desirable managing strategy to reduce the surplus of males that force most zoos to use ethical culling and euthanizing management tools. We discuss these possibilities but also acknowledge that many

  17. Better Fitness in Captive Cuvier’s Gazelle despite Inbreeding Increase: Evidence of Purging?

    Science.gov (United States)

    Moreno, Eulalia; Pérez-González, Javier; Carranza, Juan; Moya-Laraño, Jordi

    2015-01-01

    Captive breeding of endangered species often aims at preserving genetic diversity and to avoid the harmful effects of inbreeding. However, deleterious alleles causing inbreeding depression can be purged when inbreeding persists over several generations. Despite its great importance both for evolutionary biology and for captive breeding programmes, few studies have addressed whether and to which extent purging may occur. Here we undertake a longitudinal study with the largest captive population of Cuvier's gazelle managed under a European Endangered Species Programme since 1975. Previous results in this population have shown that highly inbred mothers tend to produce more daughters, and this fact was used in 2006 to reach a more appropriate sex-ratio in this polygynous species by changing the pairing strategy (i.e., pairing some inbred females instead of keeping them as surplus individuals in the population). Here, by using studbook data we explore whether purging has occurred in the population by investigating whether after the change in pairing strategy a) inbreeding and homozygosity increased at the population level, b) fitness (survival) increased, and c) the relationship between inbreeding and juvenile survival, was positive. Consistent with the existence of purging, we found an increase in inbreeding coefficients, homozygosity and juvenile survival. In addition, we showed that in the course of the breeding programme the relationship between inbreeding and juvenile survival was not uniform but rather changed over time: it was negative in the early years, flat in the middle years and positive after the change in pairing strategy. We highlight that by allowing inbred individuals to mate in captive stocks we may favour sex-ratio bias towards females, a desirable managing strategy to reduce the surplus of males that force most zoos to use ethical culling and euthanizing management tools. We discuss these possibilities but also acknowledge that many other effects

  18. An electrochemical active valve

    NARCIS (Netherlands)

    Neagu, C.R.; Gardeniers, J.G.E.; Elwenspoek, M.; Kelly, J.J.

    1997-01-01

    A novel electrochemical microactuator was developed, which operates as an active valve. The microactuator consists of an electrochemical cell and a membrane that deflects because of the pressure of oxygen gas generated by electrolysis. Relatively large pressures (up to tens of bars) can be reached w

  19. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Ansanelli, E.

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  20. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  1. Aortic valve surgery - open

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otton CM, Bowow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  2. Vent Relief Valve Test

    Science.gov (United States)

    2008-01-01

    Shown is the disassembly, examination, refurbishment and testing of the LH2 ( liquid hydrogen) and LOX (liquid oxygen) vent and relief valves for the S-IVB-211 engine stage in support of the Constellation/Ares project. This image is extracted from high definition video and is the highest resolution available.

  3. Aortic valve replacement in geriatric patients with small aortic roots: are sutureless valves the future? †

    Science.gov (United States)

    Shrestha, Malakh; Maeding, Ilona; Höffler, Klaus; Koigeldiyev, Nurbol; Marsch, Georg; Siemeni, Thierry; Fleissner, Felix; Haverich, Axel

    2013-01-01

    OBJECTIVES Aortic valve replacement (AVR) in geriatric patients (>75 years) with small aortic roots is a challenge. Patient–prosthesis mismatch and the long cross-clamp time necessary for stentless valves or root enlargement are matters of concern. We compared the results of AVR with sutureless valves (Sorin Perceval), against those with conventional biological valves. METHODS Between April 2007 and December 2012, 120 isolated AVRs were performed in patients with a small annulus (<22 mm) at our centre. In 70 patients (68 females, age 77.4 ± 5.5 years), conventional valves (C group) and in 50 patients (47 females, age 79.8 ± 4.5 years), sutureless valves (P group) were implanted. The Logistic EuroSCORE of the C group was 16.7 ± 10.4 and that of the P group 20.4 ± 10.7, (P = 0.054). Minimal-access surgery was performed in 4.3% (3/70) patients in the C group and 72% (36/50) patients in the P group. RESULTS The cardiopulmonary bypass (CPB) and cross-clamp times of the C group were 75.3 ± 23 and 50.3 ± 14.2 min vs 58.7 ± 20.9 and 30.1 ± 9 min in the P group, (P < 0.001). In the C group, two annulus enlargements were performed. Thirty-day mortality was 4.3% (n = 3) in the C group and 0 in the P group, (n.s.). At follow-up (up to 5 years), mortalities were 17.4% (n = 12) in the C group and 14% (n = 7) in the P group, (n.s.). CONCLUSIONS This study highlights the advantages of sutureless valves for geriatric patients with small aortic roots reflected by shorter cross-clamp and CPB times, even though most of these patients were operated on via a minimally invasive access. Moreover, due to the absence of a sewing ring, these valves are also almost stentless, with greater effective orifice area (EOA) for any given size. This may potentially result in better haemodynamics even without the root enlargement. This is of advantage, as several studies have shown that aortic root enlargement can significantly increase the risks of AVR. Moreover, as seen in this series

  4. NHI program for introducing thoracoscopic minimally invasive mitral and tricuspid valve surgery

    Directory of Open Access Journals (Sweden)

    Tamer El Banna

    2014-03-01

    Conclusions: Thoracoscopic minimally invasive mitral valve surgery can be performed safely but definitely requires a learning curve. Good results and a high patient satisfaction are guaranteed. We now utilize this approach for isolated atrioventricular valve disease and our plan is to make this exclusive by the end of this year for all the patients except Redo Cases.

  5. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  6. Measurement of reed valve kinematics

    Science.gov (United States)

    Fenkl, Michael; Dvořák, Václav; Vít, Tomáš

    2016-03-01

    The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  7. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Kalyani Nair; C V Muraleedharan; G S Bhuvaneshwar

    2003-06-01

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the performance of mechanical heart valves. The clinical performance of mechanical heart valves is also addressed. Efforts made in India in the development of mechanical heart valves are also discussed.

  8. Inactivation of Salmonella spp., pathogenic Escherichia coli, Staphylococcus spp., or Listeria monocytogenes in chicken purge or skin using a 405-nm LED array.

    Science.gov (United States)

    Sommers, Christopher; Gunther, Nereus W; Sheen, Shiowshuh

    2017-06-01

    Raw poultry are sometimes contaminated with foodborne pathogens, which can lead to illness in humans. In recent years research has focused on a variety of light technologies to decontaminate food and food contact surfaces during meat and poultry processing. In this study we evaluated the ability of 405-nm light generated from an LED array to inactivate multi-isolate cocktails of either Salmonella spp., pathogenic Escherichia coli, Staphylococcus spp., or Listeria monocytogenes suspended in chicken purge or skin. When exposed to 180 J/cm(2) 405-nm light at two separate light intensities (300 mW/cm(2)/s or 150 mW/cm(2)/s) the maximum pathogen reduction on chicken skin was ca. 0.4 log. When the pathogens were suspended in chicken purge the maximum log reductions ranged from 0.23 to 0.68 log (180 J/cm(2); 150 mW/cm(2)/s) versus 0.69 to 1.01 log (180 J/cm(2); 300 mW/cm(2)/s). Log reductions of each pathogen, when they were subjected to heat shock prior to 405-nm light treatment, were reduced, indicating that thermal effects accounted for much of the bacterial inactivation. Published by Elsevier Ltd.

  9. Percutaneous tricuspid valve replacement in childhood

    Directory of Open Access Journals (Sweden)

    Mathias Emmel

    2015-01-01

    Full Text Available Percutaneous replacement of the tricuspid valve with a bovine jugular venous valve (melody valve was successfully undertaken in a 9-year-old boy. The patient had a previous history of bacterial endocarditis of the native tricuspid valve in infancy. Initially, a pericardial patch valve was created, followed by surgical replacement of the valve using a biological tissue valve at 4 years of age. Progressive stenosis and regurgitation of the biological valve, with severe venous congestion and resulting hepatic dysfunction prompted percutaneous valve replacement.

  10. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets fo...

  11. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  12. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...

  13. Minimally Invasive Mitral Valve Replacement and Transfemoral Aortic Valve Implantation.

    Science.gov (United States)

    Rustenbach, Christian; Baumbach, Hardy; Hill, Stephan; Franke, Ulrich F W

    2015-01-01

    The case is reported of a symptomatic elderly patient with severe mitral regurgitation, severe aortic valve stenosis, and coronary heart disease. The coronary artery disease had been interventionally treated four years previously with stent implantation into the right coronary artery. Published studies have shown that a combination of mitral and aortic valve surgery is associated with a significantly increased risk of mortality and morbidity, particularly in elderly patients. In the present patient, both valvular malformations were successfully treated with a single-step interdisciplinary approach, namely an initial surgical mitral valve replacement followed by transfemoral transcatheter aortic valve replacement.

  14. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  15. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  16. Supramolecular spin valves

    Science.gov (United States)

    Urdampilleta, M.; Klyatskaya, S.; Cleuziou, J.-P.; Ruben, M.; Wernsdorfer, W.

    2011-07-01

    Magnetic molecules are potential building blocks for the design of spintronic devices. Moreover, molecular materials enable the combination of bottom-up processing techniques, for example with conventional top-down nanofabrication. The development of solid-state spintronic devices based on the giant magnetoresistance, tunnel magnetoresistance and spin-valve effects has revolutionized magnetic memory applications. Recently, a significant improvement of the spin-relaxation time has been observed in organic semiconductor tunnel junctions, single non-magnetic molecules coupled to magnetic electrodes have shown giant magnetoresistance and hybrid devices exploiting the quantum tunnelling properties of single-molecule magnets have been proposed. Herein, we present an original spin-valve device in which a non-magnetic molecular quantum dot, made of a single-walled carbon nanotube contacted with non-magnetic electrodes, is laterally coupled through supramolecular interactions to TbPc2 single-molecule magnets (Pc=phthalocyanine). Their localized magnetic moments lead to a magnetic field dependence of the electrical transport through the single-walled carbon nanotube, resulting in magnetoresistance ratios up to 300% at temperatures less than 1 K. We thus demonstrate the functionality of a supramolecular spin valve without magnetic leads. Our results open up prospects of new spintronic devices with quantum properties.

  17. Impact of failed mitral valve repair on hospital outcome of redo mitral valve procedures.

    Science.gov (United States)

    Onorati, Francesco; Gatti, Giuseppe; Perrotti, Andrea; Mariscalco, Giovanni; Reichart, Daniel; Milano, Aldo; Della Ratta, Ester; Rubino, Antonio; Santarpino, Giuseppe; Salsano, Antonio; Biancari, Fausto; Detter, Christian; Chocron, Sidney; Beghi, Cesare; De Feo, Marisa; Mignosa, Carmelo; Fischlein, Theodor; Pappalardo, Aniello; D'Errigo, Paola; Santini, Francesco; Faggian, Giuseppe

    2017-05-01

    The prognostic impact of failed mitral valve repair (FMR) on in-hospital outcome after redo mitral valve surgery has not been thoroughly investigated. Hospital outcomes after redo mitral valve surgery because of an FMR in patients from nine European centres were reported. Logistic regressions identified predictors of mortality in combined or isolated redo mitral valve operations. Hospital outcome was compared between propensity-matched cohorts with FMR and native mitral valves in the context of redo surgery and FMR versus failed prostheses. A total of 246 patients with FMR yielded a 6.5% mortality rate at redo surgery. FMR per se did not impact mortality at multivariable analysis ( P = 0.64). A preoperative Global Initiative for Chronic Obstructive Lung Disease (GOLD) score ≥2 chronic obstructive lung disease (COPD) (OR 15.2, P FMR population. GOLD ≥ 2 COPD (OR 12.3, P = 0.049), age at surgery (OR 1.15 for each incremental year, P = 0.049) and cardiopulmonary bypass duration (OR 1.02, P = 0.022) predicted mortality in isolated redo mitral valve surgery for FMR. The fourth (> 68 years = 13.8% mortality) and the fifth quintiles of age (≥73.4 years = 14.8%) reported the highest mortality (OR 3.8 and 4.2 respectively, P = 0.002) in this subgroup. Propensity-matched cohorts of FMR and native mitral valves in the context of redo surgery showed no differences in terms of mortality ( P = 0.69) and major morbidity (acute myocardial infarction P = 0.31, stroke P = 0.65, acute kidney injury P  = 1.0), whereas more perioperative dialysis ( P = 0.04) and transfusions ( P = 0.02) were noted in propensity-matched failed prostheses compared to FMR. A failed mitral repair does not impact hospital outcome of redo surgery. Given the role of severe left ventricular dysfunction and advanced age on hospital mortality rates, an early indication for redo surgery may improve outcome.

  18. A computerized system for video analysis of the aortic valve.

    Science.gov (United States)

    Vesely, I; Menkis, A; Campbell, G

    1990-10-01

    A novel technique was developed to study the dynamic behavior of the porcine aortic valve in an isolated heart preparation. Under the control of a personal computer, a video frame grabber board continuously acquired and digitized images of the aortic valve, and an analog-to-digital (A/D) converter read four channels of physiological data (flow rate, aortic and ventricular pressure, and aortic root diameter). The valve was illuminated with a strobe light synchronized to fire at the field acquisition rate of the CCD video camera. Using the overlay bits in the video board, the measured parameters were super-imposed over the live video as graphical tracing, and the resultant composite images were recorded on-line to video tape. The overlaying of the valve images with the graphical tracings of acquired data enabled the data tracings to be precisely synchronized with the video images of the aortic valve. This technique enabled us to observe the relationship between aortic root expansion and valve function.

  19. EVALUATION OF THREE-DIMENSIONAL NUMERICAL MODEL FOR SALINE INTRUSION AND PURGING IN SEWAGE OUTFALLS

    Institute of Scientific and Technical Information of China (English)

    WU Wei; YAN Zhong-min

    2007-01-01

    Saline intrusion into sewage outfalls will greatly decrease the efficiency of the structures. The numerical model for this flow has been limited to one- and two-dimensional ones. In this article, a three-dimensional numerical model for saline intrusion and purging in sewage outfalls was developed. The flow was modeled in three dimensions under turbulent conditions with the RNG turbulence model. The numerical results provided quantitative evidence of the fundamental flow mechanisms that took place during saline intrusion and purging. The comparisons of the results with that of two-dimensional model and that of experiments indicate that the three-dimensional numerical model developed in this article is more effective in predicting the internal flow in outfalls.

  20. A Clinical Study on Haunglian Fire-Purging Mixture In Treatment of 46 Cases of Primary Hypertension

    Institute of Scientific and Technical Information of China (English)

    李运伦

    2005-01-01

    In order to observe the therapeutic effects of Huanglian Fire-Purging Mixture (黄连清降合剂) on primary hypertension, 46 cases of primary hypertension in the treatment group were treated with Huanglian Fire-Purging Mixture to clear away heat from the liver, relieve mental stress, purge fire and remove toxin;and the other 26 cases of primary hypertension in the control group were treated with Niuhuang Bolus for Lowering Blood Pressure (牛黄降压丸). The effect in the treatment group was obviously superior to that in the control group (P<0.05). The Huanglian Fire-Purging Mixture shows noticeable effects 3-6 hours after medication. The mixture can improve the clinical symptoms, the left ventricular diastolic function and myocardial ischemia, correct dyslipoproteinemia and dysglycemia, and reduce blood viscosity. And it is safe and with no obvious adverse reactions.

  1. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  2. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, John J. (Bingham County, ID)

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  3. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1990-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  4. Change in field turbidity and trace element concentrations during well purging

    Science.gov (United States)

    Gibs, J.; Szabo, Z.; Ivahnenko, T.; Wilde, F.D.

    2000-01-01

    Various physical and chemical properties were monitored sequentially in the field during well purging as indicators of stabilization of the composition of the water in the well. Turbidity was monitored on site during purging of oxic water from three wells with screened intervals open to an unconfined aquifer system in the Coastal Plain of southern New Jersey to determine if stabilization of turbidity is a reliable indicator of the optimum purge time required to collect unbiased trace element samples. Concurrent split (one filtered, one unfiltered) samples collected during purging of the wells were analyzed for concentrations of trace elements so that the relationships between trace element concentrations and turbidity could be compared. Turbidity correlated with the whole water recoverable (WWR) concentration of trace element species, such as iron (Fe), aluminum (Al), and manganese (Mn) in the oxic ground water. Turbidity appeared to be independent of other field-measured characteristics of water such as conductivity, pH, temperature, and dissolved oxygen. The WWR concentrations of lead and copper, considered to be hydrophobic, correlated significantly with the sum of the WWR concentration of Fe, Al, and Mn. High values of field-measured turbidity were a key indicator of an overestimate of ambient hydrophobic trace element WWR concentrations. Stabilization of turbidity was a better indicator of stable, unfiltered trace element concentrations than were the other commonly measured field characteristics. At one well, turbidity was a better indicator of stable, filtered trace element concentrations than the other commonly measured field characteristics. As analytical methods for trace elements improve resulting in smaller MRLs (method reporting levels) and better precision, turbidity of ground water at values of less than 10 NTU (nepheiometric turbidity units) will become important in interpreting the significance of both unfiltered and filtered sample results.

  5. The purge of spanish education during franquism (1936-1975. The institutionalization of a repression

    Directory of Open Access Journals (Sweden)

    Carlos de Pablo Lobo

    2007-09-01

    Full Text Available Work on the trial against Spanish teaching profession because of politic reasons, from the beginning of the Spanish Civil War (1936-1939 to the end of the General Francisco Franco dictatorship (1939-1975. It includes a legislation research and it also studies the reasons, institutions and the different periods in which the course is going through. Key words: Repression, Purge, Spanish teaching, Civil War, Elementary education, Franquism, Education methods. 

  6. A purge and trap integrated microGC platform for chemical identification in aqueous samples.

    Science.gov (United States)

    Akbar, Muhammad; Narayanan, Shree; Restaino, Michael; Agah, Masoud

    2014-07-07

    The majority of current micro-scale gas chromatography (μGC) systems focus on air sampling to detect volatile organic compounds (VOCs). However, purging the VOCs from a water sample using microsystems is an unchartered territory. Various organic compounds used in everyday life find their way to water bodies. Some of these water organic compounds (WOCs) persist or degrade slowly, threatening not just human existence but also aquatic life. This article reports the first micro-purge extractor (μPE) chip and its integration with a micro-scale gas chromatography (μGC) system for the extraction and analysis of water organic compounds (WOCs) from aqueous samples. The 2 cm × 3 cm μPE chip contains two inlet and outlet ports and an etched cavity sealed with a Pyrex cover. The aqueous sample is introduced from the top inlet port while a pure inert gas is supplied from the side inlet to purge WOCs from the μPE chip. The outlets are assigned for draining water from the chip and for directing purged WOCs to the micro-thermal preconcentrator (μTPC). The trapped compounds are desorbed from the μTPC by resistive heating using the on-chip heater and temperature sensor, are separated by a 2 m long, 80 μm wide, and 250 μm deep polydimethylsiloxane (OV-1) coated μGC separation column, and are identified using a micro-thermal conductivity detector (μTCD) monolithically integrated with the column. Our experiments indicate that the combined system is capable of providing rapid chromatographic separation (<1.5 min) for quaternary WOCs namely toluene, tetrachloroethylene (PCE), chlorobenzene and ethylbenzene with a minimum detection concentration of 500 parts-per-billion (ppb) in aqueous samples. The proposed method is a promising development towards the future realization of a miniaturized system for sensitive, on-site and real-time field analysis of organic contaminants in water.

  7. Mitral Valve Regurgitation Causing Right Upper Lobe Pulmonary Edema

    OpenAIRE

    Young, Andrew L.; Langston, Charles S.; Schiffman, Robert L.; Shortsleeve, Michael J.

    2001-01-01

    When radiography is performed in patients with mitral regurgitation, cardiogenic pulmonary edema is a typical finding; however, asymmetric pulmonary edema has also been reported. We describe the case of a patient in whom mitral valve regurgitation caused isolated pulmonary edema in the right upper lung. We include a discussion of pulmonary edema in conjunction with mitral regurgitation.

  8. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  9. Mitral Valve Prolapse in Pregnancy

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Abstract Mitral valve prolapse is a benign condition. Mitral regurgitation is only complicated in patients with severe mitral valve prolapse. Women with mitral valve prolapse in the absence of other cardiovascular disorders tolerate pregnancy well and do not develop remarkable cardiac complications. Nevertheless, serious complications of mitral valve prolapse, including arrhythmia, infective endocarditis and cerebral ischemic events, can be present in pregnancy. Debates remain with regard to the use of prophylactic antibiotics and β-blockers in the pregnant women with mitral valve prolapse. The prognosis of the pregnant patients might be closely related to the pathological and (or functional changes of the mitral valve. Non-myxomatous mitral valve prolapse poses no or little obstetric risks in terms of pregnancy, labor and neonatal complications; whereas myxomatous mitral valve prolapse is a major etiology of valvular heart disease in women of childbearing age. In the pregnant patients with mitral valve prolapse progressing into major complications, surgical interventions are considered. Medicinal treatment of such patients with β-blockers should be a concern for the fetal safety.

  10. Innovative Stemless Valve Eliminates Emissions

    Science.gov (United States)

    2008-01-01

    Big Horn Valve Inc. (BHVI), of Sheridan, Wyoming, won a series of SBIR and Small Business Technology Transfer (STTR) contracts with Kennedy Space Center and Marshall Space Flight Center to explore and develop a revolutionary valve technology. BHVI developed a low-mass, high-efficiency, leak-proof cryogenic valve using composites and exotic metals, and had no stem-actuator, few moving parts, with an overall cylindrical shape. The valve has been installed at a methane coal gas field, and future applications are expected to include in-flight refueling of military aircraft, high-volume gas delivery systems, petroleum refining, and in the nuclear industry.

  11. Numerical investigation of the interaction between upstream cavity purge flow and main flow in low aspect ratio turbine cascade

    Institute of Scientific and Technical Information of China (English)

    Jia Wei; Liu Huoxing

    2013-01-01

    In modem gas turbines,rim seal located between the stator-disc and rotor-disc is used to prevent hot-gas ingestion into the inner stage-gap of high pressure turbine.However,the purge flow supplied to the cavity through the rim seal interacts with the main flow,producing additional aerodynamic loss due to the mixing process which plays a significant role in the formation,development and evolution of downstream secondary flow.In this paper,a set of cascade representative of low aspect ratio turbine is selected to numerically investigate the influence of upstream cavity purge flow on the hub secondary flow structure and aerodynamic loss.Cascade with/without upstream cavity and four different purge mass flow rates are all taken into account in this simulation.Then,a deep insight into the loss mechanism of interaction between purge flow and main flow is gained.The results show that the presence of cavity and purge flow has a significant impact on the main flow which not only changes the vortex structure in both the passage and upstream cavity,but also alters the cascade exit flow angle distribution along the spanwise.Moreover,aerodynamic loss in the cascade rises with the increase of purge flow rate while the sealing effect is also enhanced.Therefore,the effect of upstream cavity purge flow must be considered in the process of turbine aerodynamic design.What is more,it is necessary to minimize the purge flow rate in order to reduce aerodynamic loss on the premise of satisfying cooling requirements.

  12. Lifetime inbreeding depression, purging, and mating system evolution in a simultaneous hermaphrodite tapeworm.

    Science.gov (United States)

    Benesh, Daniel P; Weinreich, Friederike; Kalbe, Martin; Milinski, Manfred

    2014-06-01

    Classical theory on mating system evolution suggests that simultaneous hermaphrodites should either outcross if they have high inbreeding depression (ID) or self-fertilize if they have low ID. However, a mixture of selfing and outcrossing persists in many species. Previous studies with the tapeworm Schistocephalus solidus have found worms to self-fertilize some of their eggs despite ID. The probability for selfing to spread depends on the relative fitness of selfers, as well as the genetic basis for ID and whether it can be effectively purged. We bred S. solidus through two consecutive generations of selfing and recorded several fitness correlates over the whole life cycle. After one round of selfing, ID was pronounced, particularly in early-life traits, and the conservatively estimated lifetime fitness of selfed progeny was only 9% that of the outcrossed controls. After a second generation of selfing, ID remained high but was significantly reduced in several traits, which is consistent with the purging of deleterious recessive alleles (the estimated load of lethal equivalents dropped by 48%). Severe ID, even if it can be rapidly purged, likely prevents transitions toward pure selfing in this parasite, although we also cannot exclude the possibility that low-level selfing has undetected benefits.

  13. Acute gastric dilatation in a patient with anorexia nervosa binge/purge subtype.

    Science.gov (United States)

    Tweed-Kent, Ailis M; Fagenholz, Peter J; Alam, Hasan B

    2010-10-01

    Acute gastric dilatation is a rare complication of anorexia nervosa binge/purge subtype that results from gastrointestinal abnormalities, including decreased gastric motility and delayed gastric emptying. Early diagnosis and intervention is critical since delay may result in gastric necrosis, perforation, shock, and death. We report a 26-year-old female with anorexia nervosa binge/purge subtype, who presented with abdominal pain and nausea after a binge episode. Abdominal radiography and computed tomography showed a grossly dilated stomach measuring 32 cm × 17.9 cm consistent with acute gastric dilatation. She underwent exploratory laparotomy with gastrotomy and gastric decompression, and recovered uneventfully. Initially, the patient denied the binge episode, as many patients with eating disorders do, but later revealed an extensive history of anorexia nervosa binge/purge subtype. This case stresses the importance of obtaining a thorough history of eating disorders and maintaining a high index of suspicion for acute gastric dilatation in young women who present with abdominal pain and distention.

  14. The ex vivo purge of cancer cells using oncolytic viruses: recent advances and clinical implications.

    Science.gov (United States)

    Tsang, Jovian J; Atkins, Harold L

    2015-01-01

    Hematological malignancies are treated with intensive high-dose chemotherapy, with or without radiation. This is followed by hematopoietic stem cell (HSC) transplantation (HSCT) to rescue or reconstitute hematopoiesis damaged by the anticancer therapy. Autologous HSC grafts may contain cancer cells and purging could further improve treatment outcomes. Similarly, allogeneic HSCT may be improved by selectively purging alloreactive effector cells from the graft rather than wholesale immune cell depletion. Viral agents that selectively replicate in specific cell populations are being studied in experimental models of cancer and immunological diseases and have potential applications in the context of HSC graft engineering. This review describes preclinical studies involving oncolytic virus strains of adenovirus, herpes simplex virus type 1, myxoma virus, and reovirus as ex vivo purging agents for HSC grafts, as well as in vitro and in vivo experimental studies using oncolytic coxsackievirus, measles virus, parvovirus, vaccinia virus, and vesicular stomatitis virus to eradicate hematopoietic malignancies. Alternative ex vivo oncolytic virus strategies are also outlined that aim to reduce the risk of relapse following autologous HSCT and mitigate morbidity and mortality due to graft-versus-host disease in allogeneic HSCT.

  15. The influence of purge times on the yields of essential oil components extracted from plants by pressurized liquid extraction.

    Science.gov (United States)

    Wianowska, Dorota

    2014-01-01

    The influence of different purge times on the yield of the main essential oil constituents of rosemary (Rosmarinus officinalis L.), thyme (Thymus vulgaris L.), and chamomile (Chamomilla recutita L.) was investigated. The pressurized liquid extraction process was performed by applying different extraction temperatures and solvents. The results presented in the paper show that the estimated yield of essential oil components extracted from the plants in the pressurized liquid extraction process is purge time-dependent. The differences in the estimated yields are mainly connected with the evaporation of individual essential oil components and the applied solvent during the purge; the more volatile an essential oil constituent is, the greater is its loss during purge time, and the faster the evaporation of the solvent during the purge process is, the higher the concentration of less volatile essential oil components in the pressurized liquid extraction receptacle. The effect of purge time on the estimated yield of individual essential oil constituents is additionally differentiated by the extraction temperature and the extraction ability of the applied solvent.

  16. Tricuspid regurgitation following left-sided valve surgery: echocardiographic evaluation and optimal timing of surgical treatment.

    Science.gov (United States)

    Izumi, Chisato

    2015-03-01

    Severe tricuspid regurgitation may often appear and progress late after left-sided valve surgery without left-sided valve dysfunction, significant left heart failure, and pulmonary hypertension. The clinical features, echocardiographic evaluation, treatment, and prognosis of this disease entity have been discussed, but data is limited compared with left-sided valve diseases. Tricuspid annular dilatation associated with atrial fibrillation and right ventricular dysfunction strongly relate to development of isolated tricuspid regurgitation late after left-sided valve surgery. Three-dimensional evaluation may be useful in evaluating tricuspid valve anatomy in more detail. Better prognosis in patients undergoing surgical treatment for severe isolated tricuspid regurgitation than those who were treated medically has been reported; however, the timing of isolated tricuspid valve surgery is often too late. Right ventricular function is a key word for determining the timing of isolated tricuspid valve surgery; however, it is difficult to evaluate by conventional echocardiography. One of the serious issues in the future will be how to accurately evaluate right ventricular function.

  17. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    BACKGROUND: Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES: This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS...

  18. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    risk factors. METHODS AND RESULTS: Observational single-center study of 509 consecutive patients treated with a transcatheter implanted self-expandable aortic valve prosthesis (Medtronic CoreValve). We identified 18 patients diagnosed with TAVI-PVE during a median follow-up period of 1.4 years...

  19. Porcine mitral valve interstitial cells in culture.

    Science.gov (United States)

    Lester, W; Rosenthal, A; Granton, B; Gotlieb, A I

    1988-11-01

    There are connective tissue cells present within the interstitium of the heart valves. This study was designed to isolate and characterize mitral valve interstitial cells from the anterior leaflet of the mitral valve. Explants obtained from the distal part of the leaflet, having been scraped free of surface endocardial cells, were incubated in medium 199 supplemented with 10% fetal bovine serum. Cells grew out of the explant after 3 to 5 days and by 3 weeks these cells were harvested and passaged. Passages 1 to 22 were characterized in several explant sets. The cells showed a growth pattern reminiscent of fibroblasts. Growth was dependent on serum concentration. Cytoskeletal localization of actin and myosin showed prominent stress fibers. Ultrastructural studies showed many elongated cells with prominent stress fibers and some gap junctions and few adherens junctions. There were as well cells with fewer stress fibers containing prominent Golgi complex and dilated endoplasmic reticulum. In the multilayered superconfluent cultures, the former cells tended to be on the substratum of the dish or surface of the multilayered culture, whereas the latter was generally located within the layer of cells. Extracellular matrix was prominent in superconfluent cultures, often within the layers as well. Labeling of the cells with antibody HHF 35 (Tsukada T, Tippens D, Gordon D, Ross R, Gown AM: Am J Pathol 126:51, 1987), which recognizes smooth muscle cell actin, showed prominent staining of the elongated stress fiber-containing cells and much less in the secretory type cells. These studies show that interstitial mitral valve cells can be grown in culture and that either two different cell types or one cell type with two phenotypic expressions is present in culture.

  20. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  1. Modified lipoprotein-derived lipid particles accumulate in human stenotic aortic valves.

    Science.gov (United States)

    Lehti, Satu; Käkelä, Reijo; Hörkkö, Sohvi; Kummu, Outi; Helske-Suihko, Satu; Kupari, Markku; Werkkala, Kalervo; Kovanen, Petri T; Oörni, Katariina

    2013-01-01

    In aortic stenosis plasma lipoprotein-derived lipids accumulate in aortic valves. Here, we first compared the lipid compositions of stenotic aortic valves and atherosclerotic plaque cores. Both pathological tissues were found to be enriched in cholesteryl linoleate, a marker of extracellularly accumulated lipoproteins. In addition, a large proportion of the phospholipids were found to contain arachidonic acid, the common precursor of a number of proinflammatory lipid mediators. Next, we isolated and characterized extracellular lipid particles from human stenotic and non-stenotic control valves, and compared them to plasma lipoproteins from the same subjects. The extracellular valvular lipid particles were isolated from 15 stenotic and 14 non-stenotic aortic valves. Significantly more apoB-100-containing lipid particles were found in the stenotic than in the non-stenotic valves. The majority of the lipid particles isolated from the non-stenotic valves had sizes (23±6.2 nm in diameter) similar to those of plasma low density lipoprotein (LDL) (22±1.5 nm), while the lipid particles from stenotic valves were not of uniform size, their sizes ranging from 18 to more than 500 nm. The lipid particles showed signs of oxidative modifications, and when compared to isolated plasma LDL particles, the lipid particles isolated from the stenotic valves had a higher sphingomyelin/phosphatidylcholine -ratio, and also higher contents of lysophosphatidylcholine and unesterified cholesterol. The findings of the present study reveal, for the first time, that in stenotic human aortic valves, infiltrated plasma lipoproteins have undergone oxidative and lipolytic modifications, and become fused and aggregated. The generated large lipid particles may contribute to the pathogenesis of human aortic stenosis.

  2. Surge-damping vacuum valve

    Science.gov (United States)

    Bullock, Jack C.; Kelly, Benjamin E.

    1980-01-01

    A valve having a mechanism for damping out flow surges in a vacuum system which utilizes a slotted spring-loaded disk positioned adjacent the valve's vacuum port. Under flow surge conditions, the differential pressure forces the disk into sealing engagement with the vacuum port, thereby restricting the flow path to the slots in the disk damping out the flow surge.

  3. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Mitral Valve Prolapse Browse the Encyclopedia A.D. ...

  4. Valve-"Health"-Monitoring System

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  5. Combination throttle and shutoff valve

    Science.gov (United States)

    Carriker, J. W.

    1972-01-01

    Combination of translating sleeve throttle valve and conventional poppet valve provides capability of shutting off flow completely by poppet and sleeve control of the rate of flow. Integration of the two concepts can be accomplished without difficulty and in a manner that requires a minimum of development.

  6. Variable gas leak rate valve

    Energy Technology Data Exchange (ETDEWEB)

    Eernisse, Errol P. (Albuquerque, NM); Peterson, Gary D. (Albuquerque, NM)

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  7. Fluid mechanics of artificial heart valves.

    Science.gov (United States)

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  8. Robotic mitral valve surgery.

    Science.gov (United States)

    Kypson, Alan P; Nifong, L Wiley; Chitwood, W Randolph

    2003-12-01

    A renaissance in cardiac surgery has begun. The early clinical experience with computer-enhanced telemanipulation systems outlines the limitations of this approach despite some procedural success. Technologic advancements, such as the use of nitinol U-clips (Coalescent Surgical Inc., Sunnyvale, CA) instead of sutures requiring manual knot tying, have been shown to decrease operative times significantly. It is expected that with further refinements and development of adjunct technologies, the technique of computer-enhanced endoscopic cardiac surgery will evolve and may prove to be beneficial for many patients. Robotic technology has provided benefits to cardiac surgery. With improved optics and instrumentation, incisions are smaller. The ergometric movements and simulated three-dimensional optics project hand-eye coordination for the surgeon. The placement of the wristlike articulations at the end of the instruments moves the pivoting action to the plane of the mitral annulus. This improves dexterity in tight spaces and allows for ambidextrous suture placement. Sutures can be placed more accurately because of tremor filtration and high-resolution video magnification. Furthermore, the robotic system may have potential as an educational tool. In the near future, surgical vision and training systems might be able to model most surgical procedures through immersive technology. Thus, a "flight simulator" concept emerges where surgeons may be able to practice and perform the operation without a patient. Already, effective curricula for training teams in robotic surgery exist. Nevertheless, certain constraints continue to limit the advancement to a totally endoscopic computer-enhanced mitral valve operation. The current size of the instruments, intrathoracic instrument collisions, and extrathoracic "elbow" conflicts still can limit dexterity. When smaller instruments are developed, these restraints may be resolved. Furthermore, a working port incision is still required for

  9. Mitral annular calcification in patients undergoing aortic valve replacement for aortic valve stenosis.

    Science.gov (United States)

    Takami, Yoshiyuki; Tajima, Kazuyoshi

    2016-02-01

    Limited data exis t on clinical relevance of aortic valve stenosis (AVS) and mitral annular calcification (MAC), although with similar pathophysiologic basis. We sought to reveal the prevalence of MAC and its clinical features in the patients undergoing aortic valve replacement (AVR) for AVS. We reviewed 106 consecutive patients who underwent isolated AVR from 2004 to 2010. Before AVR, CT scans were performed to identify MAC, whose severity was graded on a scale of 0-4, with grade 0 denoting no MAC and grade 4 indicating severe MAC. Echocardiography was performed before AVR and at follow-up over 2 years after AVR. MAC was identified in 56 patients with grade 1 (30 %), 2 (39 %), 3 (18 %), and 4 (13 %), respectively. Patients with MAC presented older age (72 ± 8 versus 66 ± 11 years), higher rate of dialysis-dependent renal failure (43 versus 4 %), and less frequency of bicuspid aortic valve (9 versus 36 %), when compared to those without MAC. No significant differences were seen in short- and mid-term mortality after AVR between the groups. In patients with MAC, progression of neither mitral regurgitation nor stenosis was observed at follow-up of 53 ± 23 months for 102 survivors, although the transmitral flow velocities were higher than in those without MAC. In conclusion, MAC represented 53 % of the patients undergoing isolated AVR for AVS, usually appeared in dialysis-dependent elder patients with tricuspid AVS. MAC does not affect adversely upon the survival, without progression of mitral valve disease, at least within 2 years after AVR.

  10. Valve-related complications after mechanical heart valve implantation.

    Science.gov (United States)

    Misawa, Yoshio

    2015-10-01

    The number of heart valve surgeries is increasing, and 19,164 patients underwent heart valve surgery in Japan in 2011. The early mortality rate has remained stable for more than 10 years. Many patients now survive for many years, with a reported 10-year survival rate of at least 60 %. However, unfavorable complications can occur after valve surgery. Valve-related complications include thromboembolisms, bleeding complications and prosthetic valve endocarditis, followed by structural and nonstructural prosthetic valve dysfunctions. Our review of studies published after 2000 revealed that the rate of all valve-related complications was 0.7-3.5 % per patient-year. Thromboembolisms occur at a rate of approximately 1 % per patient-year, and bleeding complications occur at almost 0.5 % per patient-year. Thromboembolic and hemorrhagic events related to anticoagulant therapy should be considered during life-long follow-up. The occurrence rate of endocarditis reaches 0.5 % per patient-year, with a poor postoperative survival. Structural dysfunctions have been largely overcome, and the nonstructural dysfunction rate is 0.4-1.2 % per patient-year. The nonstructural dysfunctions induced by paravalvular leaks and pannus ingrowth are also issues that need to be resolved.

  11. Patents and heart valve surgery - II: tissue valves.

    Science.gov (United States)

    Cheema, Faisal H; Kossar, Alexander P; Rehman, Atiq; Younas, Fahad; Polvani, Gianluca

    2013-08-01

    Valvular heart disease affects millions of Americans yearly and currently requires surgical intervention to repair or replace the defective valves. Through a close-knit collaboration between physicians, scientists and biomedical engineers, a vast degree of research and development has been aimed towards the optimization of prosthetic heart valves. Although various methods have made fantastic strides in producing durable prostheses, the therapeutic efficacy of prosthetic valves is inherently limited by a dependency upon lifelong anticoagulant regimens for recipients - a difficult challenge for many in clinical setting. Thus, biological tissue valves have been developed to circumvent vascular and immunemediated complications by incorporating biological materials to mimic native valves while still maintaining a necessary level of structural integrity. Over the past decade, a multitude of patents pertaining to the refinement of designs as well as the advancement in methodologies and technologies associated with biological tissue valves have been issued. This review seeks to chronicle and characterize such patents in an effort to track the past, present, and future progress as well as project the trajectory of tissue valves in the years to come.

  12. DISSOLUTION OF IRRADIATED MURR FUEL ASSEMBLIES EFFECT OF INCREASED PURGE RATE AND CATALYST CONCENTRATION ON THE BATCH SIZE

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E.

    2010-07-22

    Flowsheets for the dissolution of aluminum-clad spent nuclear fuel have been proposed using 0.002 M mercuric nitrate catalyst in 5 to 6 M nitric acid. Previous calculations for flammable gas control during the dissolution of spent nuclear fuel have been extended to cover a range of dissolver purge rates from 40 to 55 scfm. A range of dissolver solution volumes from 12000 to 15000 liters were considered for the large H-Canyon dissolver (6.4D). Depending on the purge rate, anywhere from four to six bundles of MURR fuel can be initially charged to the dissolver (6.4D). For successive charges where the dissolver solution already contains 0.002 M mercury catalyst and the dissolved aluminum from five bundles of MURR fuel, five to nine bundles of additional fuel can be charged depending on the purge rate and the dissolver solution volume. Similar calculations have been performed for the small H-Canyon dissolver (6.1D) for solution volumes that ranged from 6000 to 7500 liters and purge rates from 40 to 55 scfm. The limitations on the initial charge are four to six bundles depending on the purge rate. The aluminum from four bundles of fuel in an initial charge will allow nine to ten bundles in the second charge to 6.1D depending on the purge rate and dissolver solution volume. Solubility or criticality limitations will restrict the second charge on the small dissolver. The concentration of aluminum from previous charges will slow the dissolution rate to extend the cycle time of repeated charges of fuel. Calculations have been performed to allow a second catalyst addition (up to 0.004 M total catalyst) to reduce the cycle time (as necessary) based on the aluminum concentration and the purge rate.

  13. Human interstitial cellular model in therapeutics of heart valve calcification.

    Science.gov (United States)

    He, Caimei; Tang, Hai; Mei, Zijian; Li, Nichujie; Zeng, Zhi; Darko, Kwame Oteng; Yin, Yulong; Hu, Chien-An Andy; Yang, Xiaoping

    2017-05-23

    Calcific aortic valve disease is a common, severe heart condition that is currently with no proven, effective drug treatment and requires a surgical valve replacement or an entire heart explanation. Thus, developing novel, targeted therapeutic approaches becomes a major goal for cardiovascular disease research. To achieve this goal, isolated heart valve interstitial cells could be an advanced model to explore molecular mechanisms and measure drug efficacy. Based on this progress, molecular mechanisms that harbor components of  inflammation and fibrosis coupled with proteins, for example, BMP-2, TLRs, RANKL, Osteoprotegerin, have been proposed. Small molecules or antibodies targeting these proteins have shown promising efficacy for either reversing or slowing down calcification development in vitro. In this review, we summarize these potential therapeutics with some highlights of interstitial cellular models.

  14. PWR safety and relief valve test program. Valve selection/juftification report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1982-12-01

    NUREG 0578 required that full-scale testing be performed on pressurizer safety valves and relief valves representative of those in use or planned for use in PWR plants. To obtain valve performance data for the entire population of PWR plant valves, nine safety valves and ten relief valves were selected as a fully representative set of test valves. Justification that the selected valves represent all PWR plant valves was provided by each safety and relief valve manufacturer. Both the valve selection and justification work was performed as part of the PWR Safety and Relief Valve Test Program conducted by EPRI on behalf of the PWR utilities in response to the recommendations of NUREG 0578 and the requirements of the NRC. Results of the Safety and Relief Valve Selection and Justification effort is documented in this report.

  15. Predictive modelization of actuators tires in related valves with safety Cofrentes NPP; Modelizacion predictiva de actuadores neumaticos en valvulas relacionadas con la seguridad de C.N.Cofrentes

    Energy Technology Data Exchange (ETDEWEB)

    Calduch Cervera, F.; Verdu Rios, M. F.; Villena Rivera, M.; Munoz Guijosa, J. M.

    2011-07-01

    The main function of these valves is isolation, and in some cases this function is especially critical because they must isolate Elementary and Secondary Containment. Particularly valves must be able to ensure a perfect sealing of the lines which are installed under any conditions, whether in normal operation or in a design basis accident scenario.

  16. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Inhalation and exhalation valves; check valves... PROTECTIVE DEVICES Supplied-Air Respirators § 84.137 Inhalation and exhalation valves; check valves; minimum requirements. (a) Inhalation and exhalation valves shall be provided where necessary and protected...

  17. 49 CFR 195.116 - Valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 195.116 Section 195.116 Transportation... PIPELINE Design Requirements § 195.116 Valves. Each valve installed in a pipeline system must comply with the following: (a) The valve must be of a sound engineering design. (b) Materials subject to...

  18. 14 CFR 125.133 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 125.133 Section 125.133....133 Fuel valves. Each fuel valve must— (a) Comply with § 125.155; (b) Have positive stops or suitable... operation or from accelerated flight conditions are not transmitted to the lines connected to the valve....

  19. 49 CFR 192.145 - Valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 192.145 Section 192.145 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.145 Valves. (a) Except for cast iron and plastic valves, each valve must meet the minimum requirements of API...

  20. 14 CFR 125.137 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  1. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  2. Proportional valve with a piezoelectric actuator

    Science.gov (United States)

    Laski, Pawel Andrzej

    2016-11-01

    The article concerns a slotted proportional valve for use in pneumatic and hydraulic systems. There is a growing demand for both hydraulic and pneumatic ultrafast proportional valves. The conducted analysis of literature confirms the lack of such solutions for proportional valves. The currently used pneumatic systems for selection and segregation of parts and objects require ultrafast valves. The presented solution for the proportional valve can significantly improve and accelerate this type of technological processes. Furthermore, fast proportional valves can be successfully used for positional control of pneumatic and hydraulic drives. The article presents the design of a slotted divide valve and sets the maximum mass flow rate for service roads.

  3. Proportional valve with a piezoelectric actuator

    Directory of Open Access Journals (Sweden)

    Laski Pawel Andrzej

    2017-01-01

    Full Text Available The article concerns a slotted proportional valve for use in pneumatic and hydraulic systems. There is a growing demand for both hydraulic and pneumatic ultrafast proportional valves. The conducted analysis of literature confirms the lack of such solutions for proportional valves. The currently used pneumatic systems for selection and segregation of parts and objects require ultrafast valves. The presented solution for the proportional valve can significantly improve and accelerate this type of technological processes. Furthermore, fast proportional valves can be successfully used for positional control of pneumatic and hydraulic drives. The article presents the design of a slotted divide valve and sets the maximum mass flow rate for service roads.

  4. Double prosthetic aortic valve. Case report.

    Science.gov (United States)

    Liddicoat, J E; Bekassy, S M; De Bakey, M E

    1975-05-01

    A 55-year-old man underwent insection of a Hufnagel valve into his descending thoracic aorta for aortic valve insufficiency 18 years ago. He remained asymptomatic for 16 years. Because of progressive left ventricular failure his incompetent aortic valve was replaced with a De Bakey carbon ball aortic valve prosthesis 2 years later. Currently, 21 months after the operation, he is doing well with two aortic valves. Review of the literature suggests that he is the first patient reported with two aortic valves functioning concomitantly and one of the longest surviving patients with a Hufnagel valve.

  5. Space Station Environmental Control and Life Support System Purge Control Pump Assembly Modeling and Analysis

    Science.gov (United States)

    Schunk, R. Gregory; Hunt, Patrick L. (Technical Monitor)

    2001-01-01

    Preliminary results from a thermal/flow analysis of the Purge Control Pump Assembly (PCPA) indicate that pump performance (mass flow rate) is enhanced via cooling of the housing and lowering of the inlet vapor quality. Under a nominal operational profile (25% duty cycle or less), at the maximum motor dissipation, it appears that the peristaltic tubing temperature will still remain significantly below the expected UPA condenser temperature (78 F max versus approximately 105 F in the condenser) permitting condensation in the pump head.

  6. Cryogenic system with GM cryocooler for krypton, xenon separation from hydrogen-helium purge gas

    Energy Technology Data Exchange (ETDEWEB)

    Chu, X. X.; Zhang, D. X.; Qian, Y.; Liu, W. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201800 (China); Zhang, M. M.; Xu, D. [Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190 (China)

    2014-01-29

    In the thorium molten salt reactor (TMSR), fission products such as krypton, xenon and tritium will be produced continuously in the process of nuclear fission reaction. A cryogenic system with a two stage GM cryocooler was designed to separate Kr, Xe, and H{sub 2} from helium purge gas. The temperatures of two stage heat exchanger condensation tanks were maintained at about 38 K and 4.5 K, respectively. The main fluid parameters of heat transfer were confirmed, and the structural heat exchanger equipment and cold box were designed. Designed concentrations after cryogenic separation of Kr, Xe and H{sub 2} in helium recycle gas are less than 1 ppb.

  7. Cryogenic system with GM cryocooler for krypton, xenon separation from hydrogen-helium purge gas

    Science.gov (United States)

    Chu, X. X.; Zhang, M. M.; Zhang, D. X.; Xu, D.; Qian, Y.; Liu, W.

    2014-01-01

    In the thorium molten salt reactor (TMSR), fission products such as krypton, xenon and tritium will be produced continuously in the process of nuclear fission reaction. A cryogenic system with a two stage GM cryocooler was designed to separate Kr, Xe, and H2 from helium purge gas. The temperatures of two stage heat exchanger condensation tanks were maintained at about 38 K and 4.5 K, respectively. The main fluid parameters of heat transfer were confirmed, and the structural heat exchanger equipment and cold box were designed. Designed concentrations after cryogenic separation of Kr, Xe and H2 in helium recycle gas are less than 1 ppb.

  8. Measurement of residual solvents in a drug substance by a purge-and-trap method.

    Science.gov (United States)

    Lakatos, Miklós

    2008-08-05

    The purge-and-trap (P&T) gas extraction method combined with gas chromatography was studied for its suitability for quantitative residual solvents determination in a water-soluble active pharmaceutical ingredient (API). Some analytical method performance characteristics were investigated, namely, the repeatability, the accuracy and the detection limit of determination. The results show that the P&T technique is--as expected--more sensitive than the static headspace, thus it can be used for the determination of residual solvents pertaining to the ICH Class 1 group. It was found that it could be an alternative sample preparation method besides the static headspace (HS) method.

  9. [MITRAL VALVE REPAIR WITH MINIMALLY INVASIVE CARDIAC SURGERY APPROACH AS ROUTINE PRACTICE].

    Science.gov (United States)

    Okamoto, Kazuma; Kudo, Mikihiko; Shimizu, Hideyuki

    2016-03-01

    Although minimally invasive cardiac surgery (MICS) via right minithoracotomy is attracting attention as a minimally invasive approach in cardiac surgery, it has not become a standard, routine approach for mitral valve repair. Although it has spread rapidly in Germany (43%) and USA (20.4%), the proportion of MICS in isolated mitral valve repair still comprises only 15.6% of mitral valve repair surgeries in Japan. For safe, assured introduction of MICS as a routine approach under quality control for good surgical and mid- and long-term results, surgeons experienced in mitral valve repair who perform at least 10 mitral valve repairs per year are necessary. A team approach with surgeons, anesthesiologists, perfusionists, and nurses who are highly motivated is also important.

  10. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  11. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  12. Operation of a Rotary-valved Pulse Detonation Rocket Engine Utilizing Liquid-kerosene and Oxygen

    Institute of Scientific and Technical Information of China (English)

    WANG Ke; FAN Wei; YAN Yu; ZHU Xudong; YAN Chuanjun

    2011-01-01

    The pulse detonation rocket engine (PDRE) requires periodic supply of oxidizer,fuel and purge gas.A rotary-valve assembly is fabricated to control the periodic supply in this research.Oxygen and liquid aviation kerosene are used as oxidizer and fuel respectively.An ordinary automobile spark plug,with ignition energy as low as 50 mJ,is used to initiate combustion.Steady operation of the PDRE is achieved with operating frequency ranging from 1 Hz to 10 Hz.Experimentally measured pressure is lower than theoretical value by 13% at 1 Hz and 37% at 10 Hz,and there also exists a velocity deficit at different operating frequencies.Both of these two phenomena are believed mainly due to droplet size which depends on atomization and vaporization of liquid fuel.

  13. Human tissue valves in aortic position: determinants of reoperation and valve regurgitation

    NARCIS (Netherlands)

    T.P. Willems (Tineke); E.W. Steyerberg (Ewout); V.E. Kleyburg-Linkers; E. Bos (Egbert); L.A. van Herwerden (Lex); J.R.T.C. Roelandt (Jos); J.J.M. Takkenberg (Hanneke)

    2001-01-01

    textabstractBACKGROUND: Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve

  14. Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation

    NARCIS (Netherlands)

    J.P.A. Puvimanasinghe (John); M.B. Edwards; M.J.C. Eijkemans (René); E.W. Steyerberg (Ewout); L.A. van Herwerden (Lex); K.M. Taylor; G.L. Grunkemeier (Gary); J.D.F. Habbema (Dik); A.J.J.C. Bogers (Ad); J.J.M. Takkenberg (Hanneke)

    2004-01-01

    textabstractBACKGROUND: Mechanical valves and bioprostheses are widely used for aortic valve replacement. Though previous randomised studies indicate that there is no important difference in outcome after implantation with either type of valve, knowledge of outcomes after aortic va

  15. Cutting precision in a novel aortic valve resection tool. Research in progress.

    Science.gov (United States)

    Wendt, Daniel; Stühle, Sebastian; Wendt, Hermann; Thielmann, Matthias; Kipfmüller, Brigitte; Hauck, Florian; Vogel, Bernd; Jakob, Heinz

    2009-10-01

    We recently demonstrated the first in-vitro cutting results of a minimal-invasive aortic valve resection tool. The current study was designed to assess the cutting accuracy of this new device improved by the implementation of a linear motor-based propulsion unit. Native aortic valves of isolated swine hearts (valve diameter 17.8+/-0.9 mm, mean+/-S.D.) were artificially stenosed and calcified (n=7). Subsequently, valves were resected by the use of a new aortic valve resection tool. The cutting process was performed by fitting the instrument with foldable Nitinol cutting blades (diameter 15 mm) and two software-operated linear motors combined with separated manual rotation. Aortic valve area was measured pre- and postprocedure by software-guided binary area calculation. Aortic valve residue has been determined and the grade of accuracy has been assessed via calculating the average midpoint of the neoannulus. Furthermore, radial deviation of concentricity was calculated and cutting time was measured. Aortic valve resection was successful in all cases and nearly all leaflets (2.5+/-0.4) with a weight of 0.22+/-0.12 g were cut. Aortic valve area increased significantly (0.3+/-0.1 cm(2) vs. 1.1+/-0.2 cm(2), Pvalve by the aortic valve resection tool. Nearly all leaflets were cut and a small rim was left within the annulus, hence providing an ideal 'landing zone' for the new prosthesis. Nevertheless, the aortic valve resection tool should be enhanced by adding a centering mechanism, thus achieving a more precise cutting process in order to avoid secondary damage.

  16. Simpler valve for reciprocating engines

    Science.gov (United States)

    Akkerman, J. W.

    1978-01-01

    Simpler design eliminating camshafts, cams, and mechanical springs should improve reliability of hydrazine powered reciprocating engines. Valve is expected to improve efficiency, and reduce weight of engines in range up to 50 horsepower.

  17. Titanium in engine valve systems

    Energy Technology Data Exchange (ETDEWEB)

    Allison, J.E.; Sherman, A.M.; Bapna, M.R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a two-to-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance.

  18. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... Kawasaki Disease Long Q-T Syndrome Marfan Syndrome Metabolic Syndrome Mitral Valve Prolapse Myocardial Bridge Myocarditis Obstructive Sleep Apnea Pericarditis Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden ...

  19. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... a heart attack or injury to the heart. Rheumatic Fever Untreated strep throat or other infections with strep bacteria that progress to rheumatic fever can cause heart valve disease. When the body ...

  20. CONGENITAL QUADRICUSPID AORTIC-VALVE

    NARCIS (Netherlands)

    BROUWER, MHJ; DEGRAAF, JJ; EBELS, T

    1993-01-01

    Two patients with a quadricuspid aortic valve are described, one of them with concomitant juxtaposed coronary orifices facing the right hand facing sinus. The etiology and incidence of this congenital anomaly will be discussed.

  1. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy....... The 30-day mortality rate for the 98 patients was zero, although 14 of the 98 mini-sternotomies had to be converted to complete sternotomies intraoperatively due to technical problems. Such conversion doubled the operative time over that of the planned full sternotomies. In the group of patients whose...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  2. The spin-valve transistor

    NARCIS (Netherlands)

    Monsma, Douwe Johannes

    1998-01-01

    High density magnetic recording, magnetic random access memories, displacement and current detection, contactless switching and electronic compass applications all require magnetic field sensors with unprecedented sensitivity. The spin-valve effect (giant magnetoresistance) found in 1988 in magnetic

  3. Aortic valve replacement in octogenarians

    Directory of Open Access Journals (Sweden)

    Dark John H

    2007-07-01

    Full Text Available Abstract Background and Aims As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR in octogenarians. Methods 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37 underwent isolated AVR whilst 46% (31 underwent combined AVR and CABG. Results Follow up was 100% complete. The mean age was 83.1 ± s.d. 2.9 years, a mean gradient of 83 ± s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 ± s.d. 1.2, the logistic EuroSCORE mean 12.0 ± s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p Conclusion Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.

  4. 57. Aortic valve replacement with sutureless valve and mitral valve repair in patient with infected aortic homograft

    Directory of Open Access Journals (Sweden)

    A. attia

    2016-07-01

    Full Text Available The approach of implanting aortic sutureless valve inside the calcific homograft is suitable in redo surgery especially if associated with mitral valve surgery. Aortic valve replacement in patients who have undergone previous aortic root replacement with an aortic homograft remains a technical challenge because of homograft degeneration and the need for a redo Bentall operation. We report a case of redo aortic valve replacement (valve in valve with a sutureless valve and mitral valve repair by miniband annuloplasty in a female patient aged 64 years old who underwent aortic valve replacement with homograft 14 years ago and presented by sever aortic valve regurge and sever mitral valve regurge because of infective endocarditis. This technique allows rapid aortic valve replacement in a heavily calcified aortic root. It also avoids aortic valve size affection after mitral valve repair by ordinary methods especially in patients with small aortic annulus. This technique is particularly suitable in redo procedures for homograft degeneration, it avoids performing a redo Bentall operation with its known problems as well as to avoid patient prosthesis mismatch.

  5. Apoptotic susceptibility to DNA damage of pluripotent stem cells facilitates pharmacologic purging of teratoma risk.

    Science.gov (United States)

    Smith, Alyson J; Nelson, Natalie G; Oommen, Saji; Hartjes, Katherine A; Folmes, Clifford D; Terzic, Andre; Nelson, Timothy J

    2012-10-01

    Pluripotent stem cells have been the focus of bioengineering efforts designed to generate regenerative products, yet harnessing therapeutic capacity while minimizing risk of dysregulated growth remains a challenge. The risk of residual undifferentiated stem cells within a differentiated progenitor population requires a targeted approach to eliminate contaminating cells prior to delivery. In this study we aimed to validate a toxicity strategy that could selectively purge pluripotent stem cells in response to DNA damage and avoid risk of uncontrolled cell growth upon transplantation. Compared with somatic cell types, embryonic stem cells and induced pluripotent stem cells displayed hypersensitivity to apoptotic induction by genotoxic agents. Notably, hypersensitivity in pluripotent stem cells was stage-specific and consistently lost upon in vitro differentiation, with the mean half-maximal inhibitory concentration increasing nearly 2 orders of magnitude with tissue specification. Quantitative polymerase chain reaction and Western blotting demonstrated that the innate response was mediated through upregulation of the BH3-only protein Puma in both natural and induced pluripotent stem cells. Pretreatment with genotoxic etoposide purged hypersensitive pluripotent stem cells to yield a progenitor population refractory to teratoma formation upon transplantation. Collectively, this study exploits a hypersensitive apoptotic response to DNA damage within pluripotent stem cells to decrease risk of dysregulated growth and augment the safety profile of transplant-ready, bioengineered progenitor cells.

  6. Purge and trap with monolithic sorbent for gas chromatographic analysis of pesticides in honey.

    Science.gov (United States)

    Chienthavorn, Orapin; Dararuang, Kanittha; Sasook, Anupop; Ramnut, Narumol

    2012-01-01

    Polydivinylbenzene (P-DVB) and silica monolithic materials were synthesised in capillaries and then used to adsorb nine organonitrogen pesticides extracted from honey. After adsorption, each monolith-capillary was connected to a gas chromatograph (GC) with nitrogen-phosphorous detector (NPD). The silica monolith gave better peak shape and intensity than the P-DVB monolith. Formulation of silica monolith with tetramethoxysilane (TMOS) as a sole initiator provided better separation and higher peak intensity, compared to those with methyltrimethoxysilane (MTMS) and (3:1) TMOS/MTMS initiators. The optimum internal diameter and length of silica monolith-capillary were 0.25 mm and 5 cm, respectively. The purge and trap conditions were optimised by purging with nitrogen and heating the honey sample solution at 100 °C for 60 min. Recovery of the method was in a range of 84.95-99.71% and the detection limits of the pesticides determined by using GC-NPD and GC-mass spectrometric detector (MSD) ranged between 0.36-1.75 and 0.13-0.25 ng g(-1), respectively.

  7. Determination of cyclic volatile methylsiloxanes in biota with a purge and trap method.

    Science.gov (United States)

    Kierkegaard, Amelie; Adolfsson-Erici, Margaretha; McLachlan, Michael S

    2010-11-15

    The three cyclic volatile methylsiloxanes (cVMS), octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6), are recently identified environmental contaminants. Methods for the trace analysis of these chemicals in environmental matrices are required. A purge and trap method to prepare highly purified sample extracts with a low risk of sample contamination is presented. Without prior homogenization, the sample is heated in water, and the cVMS are purged from the slurry and trapped on an Isolute ENV+ cartridge. They are subsequently eluted with n-hexane and analyzed with GC/MS. The method was tested for eight different matrices including ragworms, muscle tissue from lean and lipid-rich fish, cod liver, and seal blubber. Analyte recoveries were consistent within and between matrices, averaging 79%, 68%, and 56% for D4, D5, and D6, respectively. Good control of blank levels resulted in limits of quantification of 1.5, 0.6, and 0.6 ng/g wet weight. The repeatability was 12% (D5) and 15% (D6) at concentrations 9 and 2 times above the LOQ. The method was applied to analyze cVMS in fish from Swedish lakes, demonstrating that contamination in fish as a result of long-range atmospheric transport is low as compared to contamination from local sources.

  8. Biological and mechanical evaluation of a Bio-Hybrid scaffold for autologous valve tissue engineering.

    Science.gov (United States)

    Jahnavi, S; Saravanan, U; Arthi, N; Bhuvaneshwar, G S; Kumary, T V; Rajan, S; Verma, R S

    2017-04-01

    Major challenge in heart valve tissue engineering for paediatric patients is the development of an autologous valve with regenerative capacity. Hybrid tissue engineering approach is recently gaining popularity to design scaffolds with desired biological and mechanical properties that can remodel post implantation. In this study, we fabricated aligned nanofibrous Bio-Hybrid scaffold made of decellularized bovine pericardium: polycaprolactone-chitosan with optimized polymer thickness to yield the desired biological and mechanical properties. CD44(+), αSMA(+), Vimentin(+) and CD105(-) human valve interstitial cells were isolated and seeded on these Bio-Hybrid scaffolds. Subsequent biological evaluation revealed interstitial cell proliferation with dense extra cellular matrix deposition that indicated the viability for growth and proliferation of seeded cells on the scaffolds. Uniaxial mechanical tests along axial direction showed that the Bio-Hybrid scaffolds has at least 20 times the strength of the native valves and its stiffness is nearly 3 times more than that of native valves. Biaxial and uniaxial mechanical studies on valve interstitial cells cultured Bio-Hybrid scaffolds revealed that the response along the axial and circumferential direction was different, similar to native valves. Overall, our findings suggest that Bio-Hybrid scaffold is a promising material for future development of regenerative heart valve constructs in children.

  9. Comparison of clinical features of left-sided infective endocarditis involving previously normal versus previously abnormal valves.

    Science.gov (United States)

    Olmos, Carmen; Vilacosta, Isidre; Fernández, Cristina; Sarriá, Cristina; López, Javier; Del Trigo, María; Ferrera, Carlos; Vivas, David; Maroto, Luis; Hernández, Miguel; Rodríguez, Enrique; San Román, José Alberto

    2014-07-15

    Native valve infective endocarditis (IE) in patients with normal valves has increased in the last decades. Whether patients with normal valves present a similar prognosis to those with pathologic valves is unresolved. Our aim is to describe epidemiologic and clinical differences between patients with left-sided IE and normal valves and those with native pathologic valves. We analyzed 945 consecutive episodes of IE, 435 of which involved left-sided nonprosthetic IE. They were classified into 2 groups: episodes in normal valves (normal group, n=173) and episodes in pathologic valves (abnormal group, n=262). Patients in the normal group were younger, Staphylococcus aureus and Streptococcus bovis were more frequently isolated, and vegetations were more frequently found. Heart failure, septic shock, and the need for surgery or death were more common. Multivariate analysis identified the following as factors independently associated with normal valve IE: agevalve IE, patients with IE on normal valves were younger, had a more virulent microbiological profile, developed heart failure and septic shock more frequently, needed more surgical procedures, and had worse prognosis.

  10. Eustachian valve endocarditis: a rare localization of right side endocarditis. A case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Terranova Antonio

    2005-09-01

    Full Text Available Abstract Background Right-sided endocarditis occurs predominantly in intravenous drug users, in patients with pacemaker or central venous lines and in patients with congenital heart disease. The vast majority of cases involve the tricuspid valve. Eustachian valve endocarditis is an uncommon disease with similar signs and symptoms of the tricuspid valve endocarditis. A series of only 16 cases of eustachian valve endocarditis are reported in the literature. Case Presentation We present a case of a 25-year old woman with intravenous drug abuse who had a staphylococcus aureus tricuspid valve endocarditis associated to eustachian valve endocarditis. Transthoracic echocardiography, as first line examination, showed the vegetations on tricuspid and eustachian valve. Conclusion Our case describe an unusual location of right side endocarditis in a intravenous drug abuser. In our case, in accord with other cases described in the literature, transthoracic echocardiography disclosed eustachian valve endocarditis. Antimicrobial management is not altered by the recognition of eustachian valve endocarditis. Antibiotic treatment and duration of eustachian endocarditis depends on the isolated organism and is similar to antibiotic therapy used in native valve endocarditis.

  11. "Stolen" blood flow: effect of an open arterial filter purge line in a simulated neonatal CPB model.

    Science.gov (United States)

    Wang, Shigang; Miller, Akemi; Myers, John L; Undar, Akif

    2008-01-01

    The purpose of this study was to evaluate the effect of different flow rates and pressures on the degree of shunting of blood flow by the arterial filter purge line in a simulated neonatal cardiopulmonary bypass circuit. The circuit was primed with heparinized bovine blood (hematocrit 24%) and postfilter pressure was varied from 60-180 mm Hg (20 mm Hg increments) using a Hoffman clamp. Trials were conducted at flow rates ranging from 200-600 ml/min (100 ml/min increments). During trials conducted at a postfilter pressure of 60 mm Hg, 42.6% of blood flow was shunted through the purge line at a flow rate of 200 ml/min, whereas only 12.8% of flow was diverted at a flow rate 600 ml/min. During trials conducted at a postfilter pressure of 180 mm Hg, 82.8% of blood flow at 200 ml/min and 25.9% of blood flow at 600 ml/min was diverted through the open arterial purge line. The results of this study confirm that a significant amount of flow is diverted away from the patient when the arterial purge line is open. Shunting of blood flow through the arterial purge line could result in less effective tissue perfusion, particularly at low flow rates and high postfilter pressures. To minimize hypoperfusion injury, a flow probe (distal to the arterial filter) may be used to monitor real-time arterial flow in the setting of an open arterial filter purge line.

  12. Late prosthetic valve endocarditis due to Cardiobacterium hominis, an unusual complication

    Directory of Open Access Journals (Sweden)

    Shivaprakasha S

    2007-01-01

    Full Text Available We report a case of prosthetic valve endocarditis caused by Cardiobacterium hominis in a patient who had undergone atrial septal defect closure and mitral valve replacement of the heart in 1978. He presented with pyrexia of unknown origin and congestive cardiac failure. Investigations revealed infective endocarditis of prosthetic valve in mitral portion. Blood culture samples grew C. hominis . The patient was empirically started on vancomycin and gentamicin intravenously and ceftriaxone was added after isolation of the organism. Though subsequent blood cultures were negative, patient remained in congestive cardiac failure and died due to complications.

  13. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  14. TCT-670 Optimal Transcatheter Heart Valve Sizing in Aortic Valve in Valve Implantation: Insights from the Valve in Valve International Data (VIVID) Registry

    DEFF Research Database (Denmark)

    Alnasser, Sami; Cheema, Asim N; Horlick, Eric

    2016-01-01

    Background: Optimal transcatheter heart valve (THV) sizing is crucial to optimize procedural outcomes. Larger THV oversizing is shown to decrease paravalvular leakage post transcatheter aortic valve replacement but its role in Valve in Valve implantation (ViV) is not well established. Methods...... group received a larger THV (25.5± 1.4 mm vs. 23.3 ± 1.0 mm, pimplantation, the oversized group achieved a larger EOA (1.54±0.4cm2 vs. 1.37± 0.5cm2, p...V implantation was associated with favorable post-implant EOA and gradient but a higher risk of aortic insufficiency and THV re-intervention. Further exploration within various THV and surgical valve types at different degree of THV oversizing is planned....

  15. Right Minithoracotomy Approach for Replacement of the Ascending Aorta, Hemiarch, and Aortic Valve.

    Science.gov (United States)

    Lamelas, Joseph; LaPietra, Angelo

    2016-01-01

    A minimally invasive right anterior thoracotomy approach is the preferred technique used at our institution for isolated aortic valve pathology. We have recently introduced more complex concomitant minimally invasive procedures through this access site. Here, we describe how we perform a replacement of the ascending aorta and aortic valve with and without the use of circulatory arrest through a 6-cm right minimally invasive thoracotomy incision.

  16. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  17. Concomitant aortic valve replacement and myocardial revascularization.

    Science.gov (United States)

    Craver, J M; Jones, E L; Hatcher, C R; Farmer, J H

    1977-01-01

    Twenty-six consecutive patients underwent combined aortic valve replacement and myocardial revascularization at the Emory University Affiliated Hospitals between May, 1973 and March, 1976. Acute myocardial infarction resulted in two operative deaths (8%). There have been four late deaths, all Class IV preoperative. The age range was 37 to 79 years with an average age of 60. Preoperatively all patients were Class IV or late Class III. Twenty-three patients had symptoms of angina pectoris; congestive heart failure was evident in 56%. Postoperatively, 70% are now Class 1 or II. Single coronary bypass was performed in 16 patients, double in 6, and triple in three. Double bypass plus mitral valve replacement was required in two with aneurysmectomy in one. The rate of intraoperative infarction was 27% for the series but only 7% in the last year. The methods of intraoperative myocardial preservation and the technical approach for the operative procedures were variable. Results with each method are correlated, and currently preferred techniques are presented and discussed. Best results were obtained in patients who presented early in their symptomatic course with isolated proximal coronary lesions and good renoff vessels. Excellent results could be achieved despite advanced age of patients, requirement for multiple bypass grafts, and correction of other associated cardiac lesions. Poorest results were obtained when long-standing ventricular failure was combined with poor vessels distal to coronary stenoses. PMID:860881

  18. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  19. Analysis of Complex Valve and Feed Systems

    Science.gov (United States)

    Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Cavallo, Peter; Dash, Sanford

    2007-01-01

    A numerical framework for analysis of complex valve systems supports testing of propulsive systems by simulating key valve and control system components in the test loop. In particular, it is designed to enhance the analysis capability in terms of identifying system transients and quantifying the valve response to these transients. This system has analysis capability for simulating valve motion in complex systems operating in diverse flow regimes ranging from compressible gases to cryogenic liquids. A key feature is the hybrid, unstructured framework with sub-models for grid movement and phase change including cryogenic cavitations. The multi-element unstructured framework offers improved predictions of valve performance characteristics under steady conditions for structurally complex valves such as pressure regulator valve. Unsteady simulations of valve motion using this computational approach have been carried out for various valves in operation at Stennis Space Center such as the split-body valve and the 10-in. (approx.25.4-cm) LOX (liquid oxygen) valve and the 4-in. (approx.10 cm) Y-pattern valve (liquid nitrogen). Such simulations make use of variable grid topologies, thereby permitting solution accuracy and resolving important flow physics in the seat region of the moving valve. An advantage to this software includes possible reduction in testing costs incurred due to disruptions relating to unexpected flow transients or functioning of valve/flow control systems. Prediction of the flow anomalies leading to system vibrations, flow resonance, and valve stall can help in valve scheduling and significantly reduce the need for activation tests. This framework has been evaluated for its ability to predict performance metrics like flow coefficient for cavitating venturis and valve coefficient curves, and could be a valuable tool in predicting and understanding anomalous behavior of system components at rocket propulsion testing and design sites.

  20. Titanium in Engine Valve Systems

    Science.gov (United States)

    Allison, J. E.; Sherman, A. M.; Bapna, M. R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a twoto-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance. When properly manufactured, titanium valves have been shown to withstand very stringent durability testing, indicating the technical feasibility of this approach to fuel economy improvement.

  1. Large Scale Magnetostrictive Valve Actuator

    Science.gov (United States)

    Richard, James A.; Holleman, Elizabeth; Eddleman, David

    2008-01-01

    Marshall Space Flight Center's Valves, Actuators and Ducts Design and Development Branch developed a large scale magnetostrictive valve actuator. The potential advantages of this technology are faster, more efficient valve actuators that consume less power and provide precise position control and deliver higher flow rates than conventional solenoid valves. Magnetostrictive materials change dimensions when a magnetic field is applied; this property is referred to as magnetostriction. Magnetostriction is caused by the alignment of the magnetic domains in the material s crystalline structure and the applied magnetic field lines. Typically, the material changes shape by elongating in the axial direction and constricting in the radial direction, resulting in no net change in volume. All hardware and testing is complete. This paper will discuss: the potential applications of the technology; overview of the as built actuator design; discuss problems that were uncovered during the development testing; review test data and evaluate weaknesses of the design; and discuss areas for improvement for future work. This actuator holds promises of a low power, high load, proportionally controlled actuator for valves requiring 440 to 1500 newtons load.

  2. Determination of phosphine: comparison of rates of desorption by purge-and-trap method and by sulfuric acid treatment.

    Science.gov (United States)

    Saeed, T; Abu-Tabanja, R

    1985-01-01

    Two methods were compared for quantitative determination of phosphine present on fumigated food and materials. The rate of desorption of PH3 by using a purge-and-trap method was shown to be much slower when compared with sulfuric acid treatment and was also simpler. Application of the modified sulfuric acid treatment for real samples is described.

  3. Influence of negative affect on decision making in women with restrictive and binge-purge type anorexia nervosa

    NARCIS (Netherlands)

    Danner, Unna N; Sternheim, Lot; Bijsterbosch, Jojanneke M; Dingemans, Alexandra E; Evers, Catharine; van Elburg, Annemarie A

    2016-01-01

    The present study aims to examine the influence of negative affect on decision making in women with anorexia nervosa (AN) compared to healthy control women and, secondly, to assess differences between the restrictive (ANR) and binge-purge (ANBP) subtypes. One hundred four women (32 with ANR, 32 with

  4. Purging deleterious mutations under self fertilization: paradoxical recovery in fitness with increasing mutation rate in Caenorhabditis elegans.

    Directory of Open Access Journals (Sweden)

    Levi T Morran

    Full Text Available BACKGROUND: The accumulation of deleterious mutations can drastically reduce population mean fitness. Self-fertilization is thought to be an effective means of purging deleterious mutations. However, widespread linkage disequilibrium generated and maintained by self-fertilization is predicted to reduce the efficacy of purging when mutations are present at multiple loci. METHODOLOGY/PRINCIPAL FINDINGS: We tested the ability of self-fertilizing populations to purge deleterious mutations at multiple loci by exposing obligately self-fertilizing populations of Caenorhabditis elegans to a range of elevated mutation rates and found that mutations accumulated, as evidenced by a reduction in mean fitness, in each population. Therefore, purging in obligate selfing populations is overwhelmed by an increase in mutation rate. Surprisingly, we also found that obligate and predominantly self-fertilizing populations exposed to very high mutation rates exhibited consistently greater fitness than those subject to lesser increases in mutation rate, which contradicts the assumption that increases in mutation rate are negatively correlated with fitness. The high levels of genetic linkage inherent in self-fertilization could drive this fitness increase. CONCLUSIONS: Compensatory mutations can be more frequent under high mutation rates and may alleviate a portion of the fitness lost due to the accumulation of deleterious mutations through epistatic interactions with deleterious mutations. The prolonged maintenance of tightly linked compensatory and deleterious mutations facilitated by self-fertilization may be responsible for the fitness increase as linkage disequilibrium between the compensatory and deleterious mutations preserves their epistatic interaction.

  5. Increases in frontostriatal connectivity are associated with response to dorsomedial repetitive transcranial magnetic stimulation in refractory binge/purge behaviors

    Directory of Open Access Journals (Sweden)

    Katharine Dunlop

    2015-01-01

    Conclusions: Enhanced frontostriatal connectivity was associated with responders to dmPFC-rTMS for binge/purge behavior. rTMS caused paradoxical suppression of frontostriatal connectivity in nonresponders. rs-fMRI could prove critical for optimizing stimulation parameters in a future sham-controlled trial of rTMS in disordered eating.

  6. Seasonal patterns of birth for subjects with bulimia nervosa, binge eating, and purging: results from the National Women's Study.

    Science.gov (United States)

    Brewerton, Timothy D; Dansky, Bonnie S; O'Neil, Patrick M; Kilpatrick, Dean G

    2012-01-01

    Studies of birth patterns in anorexia nervosa have shown relative increases between March and August, while studies in Bulimia Nervosa (BN) have been negative. Since there are no studies using representative, nonclinical samples, we looked for seasonal birth patterns in women with BN and in those who ever endorsed bingeing or purging. A national, representative sample of 3,006 adult women completed structured telephone interviews including screenings for bulimia nervosa (BN) and questions about month, date, and year of birth. Season of birth was calculated using traditional definitions. Differences across season of birth between subjects with (n = 85) and without BN (n = 2,898), those with (n = 749) and without bingeing (n = 2,229), and those with (n = 267) and without any purging (n = 2,715) were compared using chi-square analyses. There were significant differences across season of birth between subjects: (1) with and without BN (p = 0.033); (2) with and without bingeing (p = 0.034), and; (3) with and without purging (p = 0.001). Fall had the highest relative number of births for all categories, while spring had the lowest. In a national representative study of nontreatment seeking subjects significant differences in season of birth were found for subjects with lifetime histories of BN, binge eating and purging. © 2011 by Wiley Periodicals, Inc. (Int J Eat Disord 2012). Copyright © 2011 Wiley Periodicals, Inc.

  7. Enhanced selectivity of hyperthermic purging of human progenitor cells using Goralatide, an inhibitor of cell cycle progression

    NARCIS (Netherlands)

    Wierenga, PK; Brenner, MK; Konings, AWT

    1998-01-01

    Recurrence of leukemia is a major problem after autologous stem cell transplantation. One potential means of reducing this risk is to purge the autologous transplant in vitro by hyperthermia, We have demonstrated that after a hyperthermic treatment of 120 min at 43 degrees C, the leukemic progenitor

  8. Identification of Aroma Compounds of Lamiaceae Species in Turkey Using the Purge and Trap Technique

    Directory of Open Access Journals (Sweden)

    Ahmet Salih Sonmezdag

    2017-02-01

    Full Text Available The present research was planned to characterize the aroma composition of important members of the Lamiaceae family such as Salvia officinalis, Lavandula angustifolia and Mentha asiatica. Aroma components of the S. officinalis, L. angustifolia and M. asiatica were extracted with the purge and trap technique with dichloromethane and analyzed with the gas chromatography–mass spectrometry (GC–MS technique. A total of 23, 33 and 33 aroma compounds were detected in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively including, acids, alcohols, aldehydes, esters, hydrocarbons and terpenes. Terpene compounds were both qualitatively and quantitatively the major chemical group among the identified aroma compounds, followed by esters. The main terpene compounds were 1,8-cineole, sabinene and linalool in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively. Among esters, linalyl acetate was the only and most important ester compound which was detected in all samples.

  9. Identification of Aroma Compounds of Lamiaceae Species in Turkey Using the Purge and Trap Technique.

    Science.gov (United States)

    Sonmezdag, Ahmet Salih; Kelebek, Hasim; Selli, Serkan

    2017-02-08

    The present research was planned to characterize the aroma composition of important members of the Lamiaceae family such as Salvia officinalis, Lavandula angustifolia and Mentha asiatica. Aroma components of the S. officinalis, L. angustifolia and M. asiatica were extracted with the purge and trap technique with dichloromethane and analyzed with the gas chromatography-mass spectrometry (GC-MS) technique. A total of 23, 33 and 33 aroma compounds were detected in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively including, acids, alcohols, aldehydes, esters, hydrocarbons and terpenes. Terpene compounds were both qualitatively and quantitatively the major chemical group among the identified aroma compounds, followed by esters. The main terpene compounds were 1,8-cineole, sabinene and linalool in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively. Among esters, linalyl acetate was the only and most important ester compound which was detected in all samples.

  10. Identification of Aroma Compounds of Lamiaceae Species in Turkey Using the Purge and Trap Technique

    Science.gov (United States)

    Sonmezdag, Ahmet Salih; Kelebek, Hasim; Selli, Serkan

    2017-01-01

    The present research was planned to characterize the aroma composition of important members of the Lamiaceae family such as Salvia officinalis, Lavandula angustifolia and Mentha asiatica. Aroma components of the S. officinalis, L. angustifolia and M. asiatica were extracted with the purge and trap technique with dichloromethane and analyzed with the gas chromatography–mass spectrometry (GC–MS) technique. A total of 23, 33 and 33 aroma compounds were detected in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively including, acids, alcohols, aldehydes, esters, hydrocarbons and terpenes. Terpene compounds were both qualitatively and quantitatively the major chemical group among the identified aroma compounds, followed by esters. The main terpene compounds were 1,8-cineole, sabinene and linalool in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively. Among esters, linalyl acetate was the only and most important ester compound which was detected in all samples. PMID:28231089

  11. Spent nuclear fuel project cold vacuum drying facility vacuum and purge system design description

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    1998-11-30

    This document provides the System Design Description (SDD) for the Cold Vacuum Drying Facility (CVDF) Vacuum and Purge System (VPS) . The SDD was developed in conjunction with HNF-SD-SNF-SAR-O02, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998), The HNF-SD-SNF-DRD-002, 1998, Cold Vacuum Drying Facility Design Requirements, and the CVDF Design Summary Report. The SDD contains general descriptions of the VPS equipment, the system functions, requirements and interfaces. The SDD provides references for design and fabrication details, operation sequences and maintenance. This SDD has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  12. 49 CFR 179.400-19 - Valves and gages.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Valves and gages. 179.400-19 Section 179.400-19...-19 Valves and gages. (a) Valves. Manually operated shut-off valves and control valves must be... liquid flow rates. All valves must be made from approved materials compatible with the lading and...

  13. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj;

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  14. Aortic valve replacement with the Nicks annulus enlargement procedure 12 years after mitral valve replacement.

    Science.gov (United States)

    Kazama, S; Kurata, A; Yamashita, Y

    1999-10-01

    An aortic valve replacement was successfully performed employing the Nicks annulus enlargement procedure in a case of aortic valve stenosis with small annulus 12 years after mitral valve replacement. Previous mitral valve replacement does not preclude feasibility of the Nicks procedure.

  15. Transapical transcatheter valve-in-valve replacement for deteriorated mitral valve bioprosthesis without radio-opaque indicators: the "invisible" mitral valve bioprosthesis.

    Science.gov (United States)

    Rossi, Marco Luciano; Barbaro, Cristina; Pagnotta, Paolo; Cappai, Antioco; Ornaghi, Diego; Belli, Guido; Presbitero, Patrizia

    2015-02-01

    In view of the high number of bioprosthetic valves implanted during the past 30 years, an increasing number of patients are coming to medical attention because of degenerated bioprostheses. Transcatheter aortic valve-in-valve implantation has been described as a less invasive alternative to re-operation to treat severe structural valve deterioration. As far as degenerated mitral valve bioprostheses are concerned, transcatheter transapical mitral valve-in-valve replacement (TMVR) has been less commonly performed, but may also become a viable alternative to re-do replacement surgery. We describe treatment of a degenerated bioprosthetic mitral valve, characterised by complete absence of any radio-opaque landmarks making the TMVR procedure very challenging.

  16. Percutaneous heart valves; past, present and future.

    Science.gov (United States)

    Rozeik, M M; Wheatley, D J; Gourlay, T

    2014-09-01

    Percutaneous heart valves provide a promising future for patients refused surgery on the grounds of significant technical challenges or high risk for complications. Since the first human intervention more than 10 years ago, over 50 different types of valves have been developed. The CoreValve and Edwards SAPIEN valves have both experienced clinical trials and the latter has gained FDA approval for implantation in patients considered inoperable. Current complications, such as major vascular bleeding and stroke, prevent these valves from being commonly deployed in patients considered operable in conventional surgery. This review focuses on the past and present achievements of these valves and highlights the design considerations required to progress development further. It is envisaged that, with continued improvement in valve design and with increased clinical and engineering experience, percutaneous heart valve replacement may one day be a viable option for lower-risk operable patients.

  17. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  18. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  19. 2D SIMPLIFIED SERVO VALVE

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A novel pilot stage valve called simplified 2D valve, which utilizes both rotary and linear motions of a single spool, is presented.The rotary motion of the spool incorporating hydraulic resistance bridge, formed by a damper groove and a crescent overlap opening, is utilized as pilot to actuate linear motion of the spool.A criterion for stability is derived from the linear analysis of the valve.Special experiments are designed to acquire the mechanical stiffness, the pilot leakage and the step response.It is shown that the sectional size of the spiral groove affects the dynamic response and the stiffness contradictorily and is also very sensitive to the pilot leakage.Therefore, it is necessary to establish a balance between the static and dynamic characteristics in deciding the structural parameters.Nevertheless, it is possible to sustain the dynamic response at a fairly high level, while keeping the leakage of the pilot stage at an acceptable level.

  20. Transapical Mitral Valve-in-Valve Replacement in Patient With Previous Complex Sternal Reconstruction.

    Science.gov (United States)

    Hynes, Conor F; Fatemi, Omid; Sharma, Aditya C; Nagy, Christian D; Trachiotis, Gregory D

    2016-01-01

    We present a complex case of a transapical redo mitral valve-in-valve replacement. Repeat mitral valve replacement was indicated for severe symptomatic bioprosthetic stenosis. In addition to the patient's numerous comorbidities that included diabetes, hepatic cirrhosis, ischemic cardiomyopathy, and atrial flutter, he had undergone a previous open mitral valve replacement that was complicated by sternal dehiscence requiring extensive chest wall reconstruction. Transapical approach was performed through left minithoracotomy incision with balloon-expandable valve. Transapical valve-in-valve replacement of a stenotic mitral bioprosthesis is a viable solution in a patient with previous complex chest wall reconstruction and multiple comorbidities.

  1. Pregnancy-induced remodeling of heart valves.

    Science.gov (United States)

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves.

  2. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik;

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  3. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj;

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  4. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik;

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  5. Advantages with small control valves

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Gunnar

    2008-09-15

    Between 1995 and 2005, the Swedish District Heating Association carried out several research projects concerning small dimensions on control valves. This lecture aims at giving a summary of these findings which, if they are carried out, have a great impact on the district heating system. The outcome is advantages on both the production side and the customer side. Some of the project's conclusions are as follows: 1. The simulations show that the consequences of temperature disturbances can be reduced when applying smaller control valves, especially at low outdoor temperatures (-5 deg C). 2. The consequences of flow disturbances (pump stop) are not depending on the outdoor temperature (heat demand), but results over the whole year in reduced maximum flow during the process of operation recovery. With adequately reduced valve size, the resulting maximum flow at restart can be approximately reduced to the half, leading in reduced need of pumping peak power. 3. Similarly, the maximum peak power taken from the net at net recovery will be reduced, however, this effect is not as strong as that for flow. 4. Generally, we have found clear indications for that the adjustment of the K{sub vs}-values of control valves in substations should follow a certain logical order of priority. An important factor is the location of substations in respect to the production plant and to the pressure control points in the network. Another important factor is the absolute K{sub vs}-value of the over sizing, i.e. the difference of the actual installed valve and the targeted valve size. 5. Smaller size of control valves means also an improvement of the everyday operation of the district heating net, especially in the case when flow and power peaks are expected to occur. Examples for that could be the morning peaks with increase heat and hot water demands, or such events when the air temperature is decreasing very fast because of weather phenomena. Smaller control valves will smear out the

  6. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  7. Surface spin-valve effect.

    Science.gov (United States)

    Yanson, I K; Naidyuk, Yu G; Fisun, V V; Konovalenko, A; Balkashin, O P; Triputen, L Yu; Korenivski, V

    2007-04-01

    We report an observation of spin-valve-like hysteresis within a few atomic layers at a ferromagnetic interface. We use phonon spectroscopy of nanometer-sized point contacts as an in situ probe to study the mechanism of the effect. Distinctive energy phonon peaks for contacts with dissimilar nonmagnetic outer electrodes allow localizing the observed spin switching to the top or bottom interfaces for nanometer thin ferromagnetic layers. The mechanism consistent with our data is energetically distinct atomically thin surface spin layers that can form current- or field-driven surface spin-valves within a single ferromagnetic film.

  8. Pregnancy in women with prosthetic heart valves

    NARCIS (Netherlands)

    Pieper, P. G.; Balci, A.; Van Dijk, A. P.

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis mid death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than unfractionated and low-molecular-weight heparin, but carry the risk

  9. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  10. Aerodynamic Characteristics of Tracheostomy Speaking Valves.

    Science.gov (United States)

    Fornataro-Clerici, Lisa; Zajac, David J.

    1993-01-01

    Pressure-flow characteristics were determined for four different one-way valves (Kisner, Montgomery, Olympic, and Passy-Muir) used for speech production in tracheotomy patients. Results indicated significant differences in resistance among the valves, with the resistance of one valve substantially greater than that of the normal upper airways.…

  11. 14 CFR 27.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 27.995 Section 27.995... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.995 Fuel valves. (a) There must be a positive, quick-acting valve to shut off fuel to each engine individually. (b) The control...

  12. 14 CFR 29.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 29.995 Section 29.995... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.995 Fuel valves. In addition to meeting the requirements of § 29.1189, each fuel valve must— (a) (b) Be supported so that no...

  13. 14 CFR 25.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 25.995 Section 25.995... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.995 Fuel valves. In addition to the requirements of § 25.1189 for shutoff means, each fuel valve must— (a) (b) Be supported...

  14. 14 CFR 29.1025 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil valves. 29.1025 Section 29.1025... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1025 Oil valves. (a) Each oil shutoff.... (c) Each oil valve must have positive stops or suitable index provisions in the “on” and...

  15. 14 CFR 25.1025 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil valves. 25.1025 Section 25.1025... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1025 Oil valves. (a) Each oil shutoff... feathering. (c) Each oil valve must have positive stops or suitable index provisions in the “on” and...

  16. 49 CFR 195.258 - Valves: General.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves: General. 195.258 Section 195.258... PIPELINE Construction § 195.258 Valves: General. (a) Each valve must be installed in a location that is accessible to authorized employees and that is protected from damage or tampering. (b) Each submerged...

  17. 14 CFR 121.239 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil valve must— (1) Comply with § 121.257; (2) Have positive stops or suitable index provisions in the...

  18. 14 CFR 121.235 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 121.235 Section 121.235..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel valve must— (a) Comply with § 121.257; (b) Have positive stops or suitable index provisions in the...

  19. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ....109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a combined capacity to prevent an accumulation of pressure of more than five pounds per square inch above the... ends of the safety valve discharge lines shall be located or protected so that discharged steam...

  20. Aerodynamic Characteristics of Tracheostomy Speaking Valves.

    Science.gov (United States)

    Fornataro-Clerici, Lisa; Zajac, David J.

    1993-01-01

    Pressure-flow characteristics were determined for four different one-way valves (Kisner, Montgomery, Olympic, and Passy-Muir) used for speech production in tracheotomy patients. Results indicated significant differences in resistance among the valves, with the resistance of one valve substantially greater than that of the normal upper airways.…

  1. Flow and plate motion in compressor valves

    NARCIS (Netherlands)

    Habing, Reinder André

    2005-01-01

    The Basic Valve Theory is based on steady ow characteristics. Therefore unsteady ow conditions in the model valve have been considered in order to assess effects of unsteadiness on the performance of the Basic Valve Theory. The instantaneous gas force was predicted rather accurately by the theory. H

  2. Staphylococcus saprophyticus causing native valve endocarditis.

    Science.gov (United States)

    Garduño, Eugenio; Márquez, Irene; Beteta, Alicia; Said, Ibrahim; Blanco, Javier; Pineda, Tomás

    2005-01-01

    Coagulase negative staphylococci are a rare cause of native valve endocarditis. Staphylococcus saprophyticus is a coagulase-negative Staphylococcus infrequently reported as a human pathogen, and most of the cases reported are urinary tract infections. We describe a case of native valve endocarditis attributed to this organism. The patient needed valve replacement due to heart failure.

  3. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  4. The presence of fructosamine in human aortic valves is associated with valve stiffness.

    Science.gov (United States)

    Kishabongo, Antoine S; Katchunga, Philippe; Cikomola, Justin C; De Somer, Filip M; De Buyzere, Marc L; Speeckaert, Marijn M; Delanghe, Joris R

    2016-09-01

    Human heart valves are prone to glycation, a fundamental process of ageing. The aim of this study was to establish the relationship between fructosamine formation and the mechanical properties of human aortic valves. 67 patients (age: 76±8 years) diagnosed with an aortic valve stenosis, who underwent an aortic valve replacement were enrolled. Fructosamine and calcium concentrations in aortic valves were determined. Using a transthoracic Doppler echocardiography, aortic valve orifice area and transvalvular pressure gradients were measured. In a subgroup of 32 patients, the aortic valve orifice area was sufficient to carry out mechanical testing on a LFPlus Universal material tester. An in vitro removal of fructosamine of the valve was initiated using ATP-dependent fructosamine 3-kinase (FN3K). A significant correlation was found between the aortic valve fructosamine concentration and the calculated aortic valve orifice area: Y (aortic valve orifice area, mm(2))=1.050-0.228X (aortic valve fructosamine concentration, µmol/g valve) (r=-0.38). A significantly higher calcium concentration was measured in the aortic valves of diabetics in comparison with those of non-diabetics. A multiple regression analysis revealed that the presence of diabetes mellitus and aortic valve fructosamine concentration were the main predictors of the extensibility of the aortic valves. In the in vitro deglycation study, a significant lower aortic valve fructosamine concentration was detected after treatment with FN3K. This resulted in an increased flexibility of the aortic valves. Although no direct causativeness is proven with the presented results, which just show an association between fructosamine, the effect of FN3K and aortic valve stiffness, the present study points for the first time towards a possible additional role of the Amadori products in the biomechanical properties of ageing aortic valves. Published by the BMJ Publishing Group Limited. For permission to use (where not

  5. Conceptual design of a compact absolute valve for the ITER neutral beam injectors

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Chris [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom)], E-mail: chris.m.jones@jet.uk; Waldon, Chris; Martin, David; Watson, Mike [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Sonderegger, Kurt; Lenherr, Bruno [VAT Vakuumventile AG, CH-9469 Haag (Switzerland); Andrews, Ian; Mansbridge, Simon [VAT Vacuum Products Ltd., Edmund House, Rugby Road, Leamington Spa, Warwickshire CV32 6EL (United Kingdom)

    2009-06-15

    The reference design for the ITER neutral beam injectors incorporated a fast shutter to limit tritium migration to the injector vacuum enclosures. In 2005, a need for an 'absolute' isolation valve was identified to facilitate injector maintenance procedures and protect the system from an in-vessel ingress of coolant event (ICE). An outline concept for an all-metal seal valve was developed during 2006, in close cooperation with the Swiss valve manufacturer VAT. During the following year, it became apparent that the length of beamline available for the valve was significantly less than originally envisaged, resulting in a radical revision of the design concept. A casing length of 760 mm has been achieved by means of major changes to the casing structure, plate dimensions, pendulum mechanism and seal actuators. A concept for a seal protection system has been developed to prevent beam line contamination reaching the valve components and to protect the valve plate from surface heating by plasma radiation. The new design concept has been extensively validated by analysis, including a whole-system FE model of the valve.

  6. Nanopatterned acellular valve conduits drive the commitment of blood-derived multipotent cells

    Science.gov (United States)

    Di Liddo, Rosa; Aguiari, Paola; Barbon, Silvia; Bertalot, Thomas; Mandoli, Amit; Tasso, Alessia; Schrenk, Sandra; Iop, Laura; Gandaglia, Alessandro; Parnigotto, Pier Paolo; Conconi, Maria Teresa; Gerosa, Gino

    2016-01-01

    Considerable progress has been made in recent years toward elucidating the correlation among nanoscale topography, mechanical properties, and biological behavior of cardiac valve substitutes. Porcine TriCol scaffolds are promising valve tissue engineering matrices with demonstrated self-repopulation potentiality. In order to define an in vitro model for investigating the influence of extracellular matrix signaling on the growth pattern of colonizing blood-derived cells, we cultured circulating multipotent cells (CMC) on acellular aortic (AVL) and pulmonary (PVL) valve conduits prepared with TriCol method and under no-flow condition. Isolated by our group from Vietnamese pigs before heart valve prosthetic implantation, porcine CMC revealed high proliferative abilities, three-lineage differentiative potential, and distinct hematopoietic/endothelial and mesenchymal properties. Their interaction with valve extracellular matrix nanostructures boosted differential messenger RNA expression pattern and morphologic features on AVL compared to PVL, while promoting on both matrices the commitment to valvular and endothelial cell-like phenotypes. Based on their origin from peripheral blood, porcine CMC are hypothesized in vivo to exert a pivotal role to homeostatically replenish valve cells and contribute to hetero- or allograft colonization. Furthermore, due to their high responsivity to extracellular matrix nanostructure signaling, porcine CMC could be useful for a preliminary evaluation of heart valve prosthetic functionality. PMID:27789941

  7. Pressure relief valve/safety relief valve testing

    Energy Technology Data Exchange (ETDEWEB)

    Murray, W.A.; Hamm, E.R.; Barber, J.R.

    1994-02-01

    Pressure vessels and piping systems are protected form overpressurization by pressure relief valves. These safety features are required to be tested-inspected on some periodic basis and, in most cases witnessed by a third party inspector. As a result nonconformances found by third parties Westinghouse Hanford Company initiated a task team to develop a pressure safety program. This paper reveals their findings.

  8. Aortic valve stenosis after previous coronary bypass: Transcatheter valve implantation or aortic valve replacement?

    Directory of Open Access Journals (Sweden)

    Jegaden Olivier

    2012-05-01

    Full Text Available Abstract We report a prospective comparison between transcatheter valve implantation (TAVI, n = 13 and surgical aortic valve replacement (AVR, n = 10 in patients with severe aortic valve stenosis and previous coronary bypass surgery (CABG. All patients had at least bilateral patent internal thoracic arteries bypass without indication of repeat revascularization. After a similar post-procedure outcome, despite one early death in TAVI group, the 1-year survival was 100% in surgical group and in transfemoral TAVI group, and 73% in transapical TAVI group. When previous CABG is the lone surgical risk factor, indications for a TAVI procedure have to be cautious, specially if transfemoral approach is not possible.

  9. Optically addressable single-use microfluidic valves by laser printer lithography.

    Science.gov (United States)

    Garcia-Cordero, Jose L; Kurzbuch, Dirk; Benito-Lopez, Fernando; Diamond, Dermot; Lee, Luke P; Ricco, Antonio J

    2010-10-21

    We report the design, fabrication, and characterization of practical microfluidic valves fabricated using laser printer lithography. These optofluidic valves are opened by directing optical energy from a solid-state laser, with similar power characteristics to those used in CD/DVD drives, to a spot of printed toner where localized heating melts an orifice in the polymer layer in as little as 500 ms, connecting previously isolated fluidic components or compartments. Valve functionality, response time, and laser input energy dependence of orifice size are reported for cyclo-olefin polymer (COP) and polyethylene terephthalate (PET) films. Implementation of these optofluidic valves is demonstrated on pressure-driven and centrifugal microfluidic platforms. In addition, these "one-shot" valves comprise a continuous polymer film that hermetically isolates on-chip fluid volumes within fluidic devices using low-vapor-permeability materials; we confirmed this for a period of one month. The fabrication and integration of optofluidic valves are compatible with a range of polymer microfabrication technologies and should facilitate the development of fully integrated, reconfigurable, and automated lab-on-a-chip systems, particularly when reagents must be stored on chip for extended periods, e.g. for medical diagnostic devices, lab-on-a-chip synthetic systems, or hazardous biochemical analysis platforms.

  10. Surgical management of tricuspid valve endocarditis in the current era: A review.

    Science.gov (United States)

    Yong, Matthew S; Coffey, Sean; Prendergast, Bernard D; Marasco, Silvana F; Zimmet, Adam D; McGiffin, David C; Saxena, Pankaj

    2016-01-01

    The incidence of isolated tricuspid valve infective endocarditis is increasing. Medical management is the mainstay of treatment but surgical intervention is required in a subset of patients. Surgical treatment options include valve excision and replacement or valve reconstruction. We searched PubMed and the Cochrane library to identify articles to be included in this review of surgical outcomes. References of selected articles were crosschecked for other relevant studies. Surgical management of tricuspid valve endocarditis can be achieved with satisfactory outcomes. However, the optimal indication and timing of surgery remain unclear, and the frequent association with intravenous drug use complicates management. Repair techniques are preferable though there is no clear evidence supporting one method over another.

  11. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  12. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Related MedlinePlus Health Topics Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  13. Microprocessor-Based Valved Controller

    Science.gov (United States)

    Norman, Arnold M., Jr.

    1987-01-01

    New controller simpler, more precise, and lighter than predecessors. Mass-flow controller compensates for changing supply pressure and temperature such as occurs when gas-supply tank becomes depleted. By periodically updating calculation of mass-flow rate, controller determines correct new position for valve and keeps mass-flow rate nearly constant.

  14. Rotary actuators for plastic valves

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, M. [Georg Fischer Piping Systems Ltd, Schaffhausen (Switzerland)

    2004-07-01

    Flexibility and modularity plus a high level of quality are the defining characteristics of this new generation of actuators from Georg Fischer. In conjunction with the new 546 ball valve, the PA 11/PA 21 pneumatic actuators and the EA 11/EA 21 electric actuators form an optimally co-ordinated system. (orig.)

  15. Analysis on Damage Cause of Belt Eyes for Bypass Feedwater Isolation Valves of Daya Bay and Ling'ao NPPs%大亚湾及岭澳核电站旁路给水隔离阀导流环缺损原因分析

    Institute of Scientific and Technical Information of China (English)

    车银辉; 关建军; 吕群贤; 杨小川

    2012-01-01

    对大亚湾及岭澳核电站所有的旁路给水隔离阀进行解体检查时,发现导流环均存在不同程度的缺损.对缺损的导流环进行宏观形貌、化学成分、金相、扫描电镜、流体力学模拟等分析.结果表明,导流环的介质流速超出厂家要求限值从而使导流环发生流体加速腐蚀和空泡腐蚀.根据导流环缺损原因,提出了相应的纠正措施.%When all of bypass feedwater isolation valves of Daya Bay and Ling'ao NPPs were inspected under disassembled condition, it was found that the belt eyes were damaged in various degrees. The analysis on macro appearance, chemical composition, metallographic, Scanning Electron Microscope and fluid mechanics simulation were carried out on the damaged belt eyes. The results show that the flow rate of belt eye is well above the manufacturer's recommendation so that flow accelerated corrosion and cavitation erosion occur on the belt eyes. According to the damage causes of the belt eyes, corresponding corrective actions are proposed.

  16. Mitral Valve Repair: The Chordae Tendineae

    Directory of Open Access Journals (Sweden)

    Carlos-A Mestres

    2015-10-01

    Full Text Available Repair of the mitral valve is the treatment of choice for mitral valve regurgitation when the anatomy is favorable. It is well known that mitral valve repair enjoys better clinical and functional results than any other type of valve substitute. This fact is beyond doubt regardless of the etiology of the valve lesion and is of particular importance in degenerative diseases.This review analyzes the most important advances in the knowledge of the anatomy, pathophysiology, and chordal function of the mitral valve as well as the different alternatives in the surgical repair and clinical results of the most prevalent diseases of the mitral valve. An attempt has been made to organize the acquired information available in a practical way.

  17. Validation of German Aortic Valve Score in a Multi-Surgeon Single Center

    Science.gov (United States)

    Kalender, Mehmet; Baysal, Ahmet Nihat; Karaca, Okay Guven; Boyacioglu, Kamil; Kayalar, Nihan

    2017-01-01

    Objective Risk assessment for operative mortality is mandatory for all cardiac operations. For some operation types such as aortic valve repair, EuroSCORE II overestimates the mortality rate and a new scoring system (German AV score) has been developed for a more accurate assessment of operative risk. In this study, we aimed to validate German Aortic Valve Score in our clinic in patients undergoing isolated aortic valve replacement. Methods A total of 35 patients who underwent isolated open aortic valve replacement between 2010 and 2013 were included. Patients with concomitant procedures and transcatheter aortic valve implantation were excluded. Patients' data were collected and analyzed retrospectively. Patients' risk scores EuroSCORE II were calculated online according to criteria described by EuroSCORE taskforce, Aortic Valve Scores were also calculated. Results The mean age of patients was 61.14±13.25 years (range 29-80 years). The number of female patients was 14 (40%) and body mass index of 25 (71.43%) patients was in range of 22-35. Mean German Aortic Valve Score was 1.05±0.96 (min: 0 max: 4.98) and mean EuroSCORE was 2.30±2.60 (min: 0.62, max: 2.30). The Aortic Valve Score scale showed better discriminative capacity (AUC 0.647, 95% CI 0.439-0.854). The goodness of fit was x2HL=16.63; P=0.436). EuroSCORE II scale had shown less discriminative capacity (AUC 0.397, 95% CI 0.200-0.597). The goodness of fit was good for both scales. The goodness of fit was x2HL=30.10; P=0.610. Conclusion In conclusion, German AV score applies to our population with high predictive accuracy and goodness of fit. PMID:28492787

  18. Validation of German Aortic Valve Score in a Multi-Surgeon Single Center

    Directory of Open Access Journals (Sweden)

    Mehmet Kalender

    Full Text Available Abstract OBJECTIVE: Risk assessment for operative mortality is mandatory for all cardiac operations. For some operation types such as aortic valve repair, EuroSCORE II overestimates the mortality rate and a new scoring system (German AV score has been developed for a more accurate assessment of operative risk. In this study, we aimed to validate German Aortic Valve Score in our clinic in patients undergoing isolated aortic valve replacement. METHODS: A total of 35 patients who underwent isolated open aortic valve replacement between 2010 and 2013 were included. Patients with concomitant procedures and transcatheter aortic valve implantation were excluded. Patients' data were collected and analyzed retrospectively. Patients' risk scores EuroSCORE II were calculated online according to criteria described by EuroSCORE taskforce, Aortic Valve Scores were also calculated. RESULTS: The mean age of patients was 61.14±13.25 years (range 29-80 years. The number of female patients was 14 (40% and body mass index of 25 (71.43% patients was in range of 22-35. Mean German Aortic Valve Score was 1.05±0.96 (min: 0 max: 4.98 and mean EuroSCORE was 2.30±2.60 (min: 0.62, max: 2.30. The Aortic Valve Score scale showed better discriminative capacity (AUC 0.647, 95% CI 0.439-0.854. The goodness of fit was x2HL=16.63; P=0.436. EuroSCORE II scale had shown less discriminative capacity (AUC 0.397, 95% CI 0.200-0.597. The goodness of fit was good for both scales. The goodness of fit was x2HL=30.10; P=0.610. CONCLUSION: In conclusion, German AV score applies to our population with high predictive accuracy and goodness of fit.

  19. Histopathology of valves in infective endocarditis, diagnostic criteria and treatment considerations.

    Science.gov (United States)

    Brandão, Tatiana J D; Januario-da-Silva, Carolina A; Correia, Marcelo G; Zappa, Monica; Abrantes, Jaime A; Dantas, Angela M R; Golebiovski, Wilma; Barbosa, Giovanna Ianini F; Weksler, Clara; Lamas, Cristiane C

    2017-04-01

    Infective endocarditis (IE) is a severe disease. Pathogen isolation is fundamental so as to treat effectively and reduce morbidity and mortality. Blood and valve culture and histopathology (HP) are routinely employed for this purpose. Valve HP is the gold standard for diagnosis. To determine the sensitivity and specificity of clinical criteria for IE (the modified Duke and the St Thomas' minor modifications, STH) of blood and valve culture compared to valve HP, and to evaluate antibiotic treatment duration. Prospective case series of patients, from 2006 to 2014 with surgically treated IE. Statistical analysis was done by the R software. There were 136 clinically definite episodes of IE in 133 patients. Mean age ± SD was 43 ± 15.6 years and IE was left sided in 81.6 %. HP was definite in 96 valves examined, which were used as gold standard. Sensitivity of blood culture was 61 % (CI 0.51, 0.71) and of valve culture 15 % (CI 0.07, 0.26). The modified Duke criteria were 65 % (CI 0.55, 0.75) sensitive and 33 % specific, while the STH's sensitivity was 72 % (CI 0.61, 0.80) with similar specificity. In multivariate analysis and logistic regression, the only variable with statistical significance was duration of antibiotic therapy postoperatively. Valve HP had high sensitivity and valve culture low sensitivity in the diagnosis of IE. The STH's criteria were more sensitive than the modified Duke criteria. Valve HP should guide duration of postoperative antibiotic treatment.

  20. Morphology of the bicuspid aortic valve and elasticity of the adjacent aorta in children.

    Science.gov (United States)

    Pees, Christiane; Michel-Behnke, Ina

    2012-11-01

    Bicuspid aortic valve (BAV) is a common congenital malformation with the known sequela of ascending aortic dilation. The morphology of the BAV and the elasticity of the adjacent ascending aorta appear to influence the outcome. We prospectively examined 48 pediatric patients with an isolated, native BAV for the morphology and size of the aortic valve, aortic root, sinotubular junction, and ascending aorta and their elasticity indexes. A cohort of 48 matching subjects with tricuspid aortic valves was investigated as controls. A comparison of the aortic valve subtypes showed normal-size aortic dimensions in the tricuspid aortic valves. In contrast, in the BAVs, the ascending aorta and aortic valve itself tended to dilate with age and aortic elasticity deteriorated. In the BAVs, the stiffness was significantly greater (4.43 ± 1.82 vs 3.43 ± 0.81 in the tricuspid aortic valves; p = 0.001). The distensibility indexes decreased inversely in the BAVs (6.57 ± 2.83 vs 7.84 ± 2.04 cm(2) × dynes(-1) × 10(-6), p = 0.013; and 53.5 ± 26.0 versus 64.3 ± 17.9 kPa(-1) × 10(-3), p = 0.020). The anteroposterior-oriented phenotype of BAVs showed significantly stiffer and less distensible elasticity even after correction for congenital valve dysfunction, which was more frequent in the left-right-oriented phenotype. In conclusion, the morphology of the BAV seems to play a major role in the outcome of BAV disease, although the left-right phenotype is more prone to congenital valve dysfunction, the anteroposterior phenotype showed worse elasticity quality.

  1. Transvalvular mitral regurgitation following mitral valve replacement a diagnostic dilemma

    OpenAIRE

    U S Dinesh Kumar; Umesh Nareppa; Shyam Prasad Shetty; Murugesh Wali

    2015-01-01

    After mitral valve replacement with a prosthetic valve, the valve should be competent and there should not be any residual prosthetic valve regurgitation. Transvalvular residual prosthetic valve regurgitation are difficult to diagnose and quantify. we are reporting interesting TEE images as a diagnostic dilemma in a case of transvalvular mitral regurgitation following mitral valve replacement secondary to entrapment of sub-valvular apparatus in a Chitra mechanical heart valve.

  2. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas;

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacement....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  3. Fault diagnosis of reciprocating compressor valve with the method integrating acoustic emission signal and simulated valve motion

    Science.gov (United States)

    Wang, Yuefei; Xue, Chuang; Jia, Xiaohan; Peng, Xueyuan

    2015-05-01

    This paper proposes a method of diagnosing faults in reciprocating compressor valves using the acoustic emission signal coupled with the simulated valve motion. The actual working condition of a valve can be obtained by analyzing the acoustic emission signal in the crank angle domain and the valve movement can be predicted by simulating the valve motion. The exact opening and closing locations of a normal valve, provided by the simulated valve motion, can be used as references for the valve fault diagnosis. The typical valve faults are diagnosed to validate the feasibility and accuracy of the proposed method. The experimental results indicate that this method can easily distinguish the normal valve, valve flutter and valve delayed closing conditions. The characteristic locations of the opening and closing of the suction and discharge valves can be clearly identified in the waveform of the acoustic emission signal and the simulated valve motion.

  4. Isolation and quantification of volatiles in fish by dynamic headspace sampling and mass spectrometry

    DEFF Research Database (Denmark)

    Refsgaard, Hanne; Haahr, Anne-Mette; Jensen, Benny

    1999-01-01

    determined by use of this sample preparation method and for samples chewed for 10 s. Effects of sampling time, temperature, and purge flow on level of volatiles were tested. Purging at 340 mL/min for 30 min at 45 degrees C was found to be optimal. Detection Emits for a number of aldehydes were 0.2-2.7 mu g......A dynamic headspace sampling method for isolation of volatiles in fish has been developed. The sample preparation involved freezing of fish tissue in liquid nitrogen, pulverizing the tissue, and sampling of volatiles from an aqueous slurry of the fish powder. Similar volatile patterns were...

  5. Early Clinical Outcome of Mitral Valve Replacement Using a Newly Designed Stentless Mitral Valve for Failure of Initial Mitral Valve Repair.

    Science.gov (United States)

    Nishida, Hidefumi; Kasegawa, Hitoshi; Kin, Hajime; Takanashi, Shuichiro

    2016-12-21

    Here we report the early outcome of mitral valve replacement using a newly designed stentless mitral valve for failure of initial mitral valve repair. Mitral valve plasty (MVP) for mitral regurgitation is currently a standard technique performed worldwide. However, whether mitral valve repair should be performed for patients with advanced leaflet damage or complicated pathology remains controversial. Mitral valve replacement might be feasible for patients who have undergone failed initial MVP; however, it is not an optimal treatment because of poor valve durability and the need for anticoagulative therapy. We report two cases of successful mitral valve replacement using a newly designed stentless mitral valve made of fresh autologous pericardium, which may have a potential benefit over mitral valve repair or mitral valve replacement with a mechanical or bioprosthetic valve.

  6. A Kinematic Analysis of the Variable Valve Timing Mechanism with Three Elements and Continuous Valve Lift

    Directory of Open Access Journals (Sweden)

    Stelian Mihalcea

    2010-01-01

    Full Text Available An innovating solution for throttle-free load control for spark-ignition engines is Variable Valve Timing system (VVT System, or VVA - Variable Valve Actuation System. In this paper is presented an analytic method for kinematic analysis of the valve timing mechanism with three elements, which mainly includes the camshaft, the roller rocker finger and an intermediate rocker arm. This type of mechanism ensures a continuous valve lift (VVL System between two extreme valve heights. It is also presented the numerical example for the variable valve lift mechanism’s motion.

  7. Redoing a bioprosthetic tricuspid valve replacement with pacemaker wire through the ruined bioprosthetic valve orifice

    Institute of Scientific and Technical Information of China (English)

    GUO Hong-wei; PAN Shi-wei; SONG Yun-hu; HU Sheng-shou

    2011-01-01

    Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.

  8. Analytical comparison and sensory representativity of SAFE, SPME, and Purge and Trap extracts of volatile compounds from pea flour.

    Science.gov (United States)

    Murat, Chloe; Gourrat, Karine; Jerosch, Heike; Cayot, Nathalie

    2012-12-01

    Pisum sativum is of great economic and nutritional interest due to its protein content. Nevertheless, pea products are underused as a protein source in human food because of their strong beany flavour. Therefore, the objective of this study was to select an efficient and representative method to extract volatile molecules of pea flour. In the first step, three extraction methods were chosen: solid phase micro extraction (SPME); Purge and Trap extraction and solvent assisted flavour evaporation (SAFE). The corresponding extracts were analysed by gas chromatography coupled with mass spectrometry. In the second step, the sensory representativity of the extracts was assessed either by direct gas chromatography-olfactometry for SPME and for Purge and Trap extracts, or by sniffing for the aqueous SAFE extract. It appeared that SAFE extraction was the most suitable method because of its good extraction capacities and its high sensory representativity of the global odour of pea flour.

  9. Spray chilling of deer carcasses--effects on carcass weight, meat moisture content, purge and microbiological quality.

    Science.gov (United States)

    Wiklund, E; Kemp, R M; leRoux, G J; Li, Y; Wu, G

    2010-12-01

    Twenty red deer carcasses were included in the study. Two treatments were applied to the carcasses; control (air chilling) and spray chilling (n=10 for each treatment). Carcass weight and temperature change were registered during over-night chilling. Meat moisture content was measured in the shoulder, loin, flap and leg before and after the chilling treatments; purge, cooking loss and tenderness were measured in loin samples stored at -1.5 °C for 3 and 9 weeks. Microbiological status was assessed on swabs taken at the lumbar end of the loin before and after the chilling treatments. Spray chilling reduced carcass weight loss significantly; air chilled and spray chilled carcasses lost 1 kg and less than 0.01 kg, respectively. No effects of spray chilling on tenderness, purge and cooking loss were found. Bacterial levels were low in general even after 9 weeks of vacuum packaged chilled storage.

  10. Study on purge gas generated in coke oven gas boilers mixing-firing process%焦炉气锅炉掺烧弛放气探讨

    Institute of Scientific and Technical Information of China (English)

    高翔

    2012-01-01

    It' s not an environmental friendly and economy way to discharged purge gas from methanol plant into the atmosphere. How to recycle methanol purge gas? The treatment of purge gas had been a general concern problem. The problem could be solved by incorpo- rating the decompression purge gas into boilers burning coke oven gas used as burning gas.%甲醇厂弛放气直接排人大气,既对环境产生污染,又无法实现经济价值。通过将弛放气减压掺入焦炉煤气中供锅炉燃烧使用的方法,可以解决弛放气的去向问题。

  11. Reduction of heat-induced haemotoxicity in a hyperthermic purging protocol of murine acute myeloid leukaemic stem cells by AcSDKP

    NARCIS (Netherlands)

    Wierenga, PK; Dillingh, JH; Konings, AWT

    1997-01-01

    The tetrapeptide AcSDKP (Goralatide) is a cytokine with known inhibitory effects on cell proliferation, Many purging agents used in autologous bone marrow transplantation protocols, including hyperthermia, preferentially kill cycling cells. A pretreatment with Goralatide offers a possibility to

  12. Hydrodynamic Performance of the Medtronic CoreValve and the Edwards SAPIEN XT Transcatheter Heart Valve in Surgical Bioprostheses: An In Vitro Valve-in-Valve Model.

    Science.gov (United States)

    Sedaghat, Alexander; Sinning, Jan-Malte; Utzenrath, Marc; Ghalati, Pejman Farhadi; Schmitz, Christoph; Werner, Nikos; Nickenig, Georg; Grube, Eberhard; Ensminger, Stephan; Steinseifer, Ulrich; Kuetting, Maximilian

    2016-01-01

    Valve-in-valve transcatheter aortic valve replacement (TAVR) is becoming a valuable option with promising clinical results in failed bioprosthetic heart valves. Sizing recommendations are based on size compatibility rather than on broad clinical data, in vitro measurements, or biomechanical evidence. The hemodynamic performance of transcatheter heart valves within degenerated surgical heart valves is unknown. We evaluated the in vitro hydrodynamic performance of two commercially available transcatheter heart valves (Medtronic CoreValve [Medtronic, Minneapolis, MN] and Edwards SAPIEN XT [Edwards Lifesciences, Irvine, CA]) in two different bioprosthetic aortic valves (Edwards Perimount [Edwards Lifesciences] and St. Jude Trifecta [St. Jude Medical, St. Paul, MN]). Within the Edwards Perimount (23 mm) prosthesis, pressure gradients were higher for the SAPIEN XT compared with the CoreValve (11.2 ± 0.1 mm Hg versus 10.1 ± 0.1 mm Hg, p < 0.01), whereas effective orifice area (1.99 ± 0.01 cm(2) versus 1.80 ± 0.01 cm(2), p < 0.01) and total paravalvular leakage (9.0% ± 1.0% versus 5.4% ± 1.3%, p < 0.01) were increased when using the CoreValve. Similarly, measurements in the St. Jude Trifecta revealed higher transvalvular pressure gradients (13.0 ± 0.2 mm Hg versus 10.9 ± 0.3 mm Hg, p < 0.01) and lower effective orifice area for the SAPIEN XT compared with the CoreValve. However, total relative regurgitation was higher with SAPIEN XT as compared with the CoreValve in St. Jude Trifecta prostheses (11.2% ± 1.4% versus 8.3% ± 0.9%, p < 0.01). Both transcatheter heart valve prostheses performed well in the described valve-in-valve settings. Hydrodynamic results were in line with the International Organization for Standardization standards for all configurations. The observed differences indicate a necessity for preclinical valve-in-valve tests in addition to clinical long-term data about longevity. Copyright © 2016 The Society of Thoracic Surgeons. Published by

  13. Low-Dose Gamma Irradiation of Decellularized Heart Valves Results in Tissue Injury in Vitro and in Vivo

    Science.gov (United States)

    Helder, Meghana R. K.; Hennessy, Ryan S.; Spoon, Daniel B.; Tefft, Brandon J.; Witt, Tyra A.; Marler, Ronald J.; Pislaru, Sorin V.; Simari, Robert D.; Stulak, John M.; Lerman, Amir

    2017-01-01

    Background Decellularized heart valves are emerging as a potential alternative to current bioprostheses for valve replacement. While techniques of decellularization have been thoroughly examined, terminal sterilization techniques have not received the same scrutiny. Methods This study evaluated low dose gamma irradiation as a sterilization method for decellularized heart valves. Incubation of valves and transmission electron microscopy evaluation after different doses of gamma irradiation were used to determine the optimal dose of gamma irradiation. Quantitative evaluation of mechanical properties was done by tensile mechanical testing of isolated cusps. Sterilize decellularized heart valves were tested in a sheep model (n=3, 1 1,500 Gy and 2 3,000 Gy) of pulmonary valve replacement. Results Valves sterilized with gamma radiation between 1,000 Gy and 3,000 Gy were found to be optimal with in-vitro testing. However, with in-vivo showed deteriorating valve function within 2 months. On explant the valve with 1,500 Gy gamma irradiation showed signs of endocarditis with neutrophils on hematoxylin and eosin staining, positive gram stain resembling streptococcus infection. The 3,000 Gy valves had no evidence of infection, but the hematoxylin and eosin staining showed evidence of wound remodeling with macrophages and fibroblasts. Tensile strength testing showed decreased strength (0 Gy-2.53±0.98 MPa, 1,500 Gy-2.03±1.23 MPa, 3,000 Gy-1.26±0.90 MPa) with increasing levels of irradiation. Conclusions Low dose gamma irradiation does not maintain the mechanical integrity of valves and the balance between sterilization and damage may not be able to be achieved with gamma irradiation. Other methods of terminal sterilization must be pursued and evaluated. PMID:26453425

  14. Unintended purge during the start-up process of a syringe pump: report of a case presented with vascular collapse.

    Science.gov (United States)

    Farbood, Arash; Kazemi, Asif Parviz; Akbari, Kamal

    2010-12-01

    The case of a 50 year-old woman who developed a sudden decrease in arterial pressure while she was being prepared for surgery for a fractured lumbar spine in the prone position, is reported. She was receiving propofol, remifentanil, and sodium nitroprusside via three syringe pumps through an intravenous cannula at the dorsum of her left hand. The cause of the vascular collapse was the purge of the syringe pumps during the self-check process.

  15. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  16. Is Transcatheter Aortic Valve Implantation of Living Tissue-Engineered Valves Feasible? An In Vitro Evaluation Utilizing a Decellularized and Reseeded Biohybrid Valve.

    Science.gov (United States)

    Koenig, Fabian; Lee, Jang-Sun; Akra, Bassil; Hollweck, Trixi; Wintermantel, Erich; Hagl, Christian; Thierfelder, Nikolaus

    2016-08-01

    Transcatheter aortic valve implantation (TAVI) is a fast-growing, exciting field of invasive therapy. During the last years many innovations significantly improved this technique. However, the prostheses are still associated with drawbacks. The aim of this study was to create cell-seeded biohybrid aortic valves (BAVs) as an ideal implant by combination of assets of biological and artificial materials. Furthermore, the influence of TAVI procedure on tissue-engineered BAV was investigated. BAV (n=6) were designed with decellularized homograft cusps and polyurethane walls. They were seeded with fibroblasts and endothelial cells isolated from saphenous veins. Consecutively, BAV were conditioned under low pulsatile flow (500 mL/min) for 5 days in a specialized bioreactor. After conditioning, TAVI-simulation was performed. The procedure was concluded with re-perfusion of the BAV for 2 days at an increased pulsatile flow (1100 mL/min). Functionality was assessed by video-documentation. Samples were taken after each processing step and evaluated by scanning electron microscopy (SEM), immunohistochemical staining (IHC), and Live/Dead-assays. The designed BAV were fully functioning and displayed physiologic behavior. After cell seeding, static cultivation and first conditioning, confluent cell layers were observed in SEM. Additionally, IHC indicated the presence of endothelial cells and fibroblasts. A significant construction of extracellular matrix was detected after the conditioning phase. However, a large number of lethal cells were observed after crimping by Live/Dead staining. Analysis revealed that the cells while still being present directly after crimping were removed in subsequent perfusion. Extensive regions of damaged cell-layers were detected by SEM-analysis substantiating these findings. Furthermore, increased ICAM expression was detected after re-perfusion as manifestation of inflammatory reaction. The approach to generate biohybrid valves is promising. However

  17. Prevalence of and Familial Influences on Purging Disorder in a Community Sample of Female Twins

    Science.gov (United States)

    Munn-Chernoff, Melissa A.; Keel, Pamela K.; Klump, Kelly L.; Grant, Julia D.; Bucholz, Kathleen K.; Madden, Pamela A. F.; Heath, Andrew C.; Duncan, Alexis E.

    2014-01-01

    Objective Purging Disorder (PD) was recently included as an Otherwise Specified Feeding or Eating Disorder (OSFED) in the DSM-5; however, limited information is available on its prevalence, and its etiology is unknown. Method Data from 1790 monozygotic and 1440 dizygotic European American female twins (age range = 18 – 29 years) from the Missouri Adolescent Female Twin Study were used to investigate prevalence and familial influences for PD. A structured clinical interview assessed lifetime DSM-IV criteria for eating disorders and PD. After adjustment for age, twin correlations and biometrical twin models were used to estimate familial (i.e., genetic plus shared environmental) influences on PD. Results One hundred and twenty one (3.77%; 95% CI: 3.14, 4.49) women met criteria for lifetime PD. Twin correlations suggested that genetic, shared environmental, and nonshared environmental factors influenced liability to PD. Nonshared environmental factors accounted for 56% [35%, 79%] of the variance in PD. Although familial effects accounted for a significant proportion of variance (44% [21%, 65%]), it was not possible to disentangle the independent contributions of additive genetic effects (20% [0%, 65%]) and shared environmental effects (24% [0%, 57%]). Discussion PD is a prevalent form of eating pathology. Familial factors are relevant to the development of PD but do not demonstrate the magnitude of heritable factors found for other eating disorders. PMID:25808399

  18. Numerical Simulation of Saline Intrusion and Purging in Long Sea Outfalls with Three-Dimensional Model

    Institute of Scientific and Technical Information of China (English)

    WU Wei; YAN Zhong-min; WU Long-hua

    2006-01-01

    Saline intrusion into marine sewage outfalls will greatly decrease the efficiency of sewage disposal. In order to investigate the mechanisms of this flow, in this paper, a three-dimensional numerical model based on FVM (Finite Volume Method) is established. The RNG k-ε model is selected for turbulence modeling. The time-averaged volume fraction equations are introduced to simulate the stratification and interfacial exchange of sewage and seawater in outfalls. Validity of the established three-dimensional numerical model is evaluated by comparisons of numerical results with experimental data. With this three-dimensional numerical model, the internal flow characteristics in outfalls for different sewage discharges are simulated. The results indicate that for a low sewage discharge, saline circulates in the outfall due to intrusion and both the inflowing momentum and the interfacial turbulent mixing are important mechanisms to extrude the saline. For a high sewage discharge, saline intrusion could be avoided. The inflow momentum is the main mechanism to extrude the saline and the interfacial turbulent mixing is not important relatively. Even at a high sewage discharge, the saline wedge would be retained in the main outfall pipe after the risers are purged. It takes a long time for this saline wedge to be extruded by interfacial turbulent mixing.

  19. Effect of self-purging pyrolysis on yield of biochar from maize cobs, husks and leaves.

    Science.gov (United States)

    Intani, Kiatkamjon; Latif, Sajid; Kabir, A K M Rafayatul; Müller, Joachim

    2016-10-01

    In this study, biochar was produced from maize residues (cobs, husks, leaves) in a lab-scale pyrolysis reactor without using a purging gas. The physicochemical properties of biomass and biochar were analysed. Box-Behnken design was used to optimise operational conditions for biochar yields. Multivariate correlations of biochar yields were established using reduced quadratic models with R(2)=0.9949, 0.9801 and 0.9876 for cobs, husks and leaves, respectively. Biochar yields were negatively correlated with the temperature, which was significantly influenced by the exothermic reactions during the pyrolysis of maize residues. The heating rate was found to have the least effect on biochar yields. Under optimal conditions, the maximum biochar yields from cobs, husks and leaves were 33.42, 30.69 and 37.91%, respectively. The highest biochar yield from maize leaves was obtained at a temperature of 300°C, a heating rate of 15°C/min and a holding time of 30min.

  20. Oncolytic viral purging of leukemic hematopoietic stem and progenitor cells with Myxoma virus.

    Science.gov (United States)

    Rahman, Masmudur M; Madlambayan, Gerard J; Cogle, Christopher R; McFadden, Grant

    2010-01-01

    High-dose chemotherapy and radiation followed by autologous blood and marrow transplantation (ABMT) has been used for the treatment of certain cancers that are refractory to standard therapeutic regimes. However, a major challenge with ABMT for patients with hematologic malignancies is disease relapse, mainly due to either contamination with cancerous hematopoietic stem and progenitor cells (HSPCs) within the autograft or the persistence of residual therapy-resistant disease niches within the patient. Oncolytic viruses represent a promising therapeutic approach to prevent cancer relapse by eliminating tumor-initiating cells that contaminate the autograft. Here we summarize an ex vivo "purging" strategy with oncolytic Myxoma virus (MYXV) to remove cancer-initiating cells from patient autografts prior to transplantation. MYXV, a novel oncolytic poxvirus with potent anti-cancer properties in a variety of in vivo tumor models, can specifically eliminate cancerous stem and progenitor cells from samples obtained from acute myelogenous leukemia (AML) patients, while sparing normal CD34+ hematopoietic stem and progenitor cells capable of rescuing hematopoiesis following high dose conditioning. We propose that a broader subset of patients with intractable hematologic malignancies who have failed standard therapy could become eligible for ABMT when the treatment schema is coupled with ex vivo oncolytic therapy.

  1. Microstructure and physical properties of steel-ladle purging plug refractory materials

    Science.gov (United States)

    Long, Bin; Xu, Gui-ying; Andreas, Buhr

    2017-02-01

    Three different castables were prepared as steel-ladle purging-plug refractory materials: corundum-based low-cement castable (C-LCC), corundum-spinel-based low-cement castable (C-S-LCC), and no-cement corundum-spinel castable (C-S-NCC) (hydratable alumina ρ-Al2O3 bonded). The properties of these castables were characterized with regard to water demand/flow ability, cold crushing strength (CCS), cold modulus of rupture (CMoR), permanent linear change (PLC), apparent porosity, and hot modulus of rupture (HMoR). The results show the CCS/CMoR and HMoR of C-LCC and C-S-LCC are greater than those of the castable C-S-NCC. According to the microstructure analysis, the sintering effect and the bonding type of the matrix material differ among the three castables. The calcium hexaluminate (CA6) phase in the matrix of C-LCC enhances the cold and hot mechanical strengths. In the case of C-S-LCC, the CA6 and 2CaO·2MgO·14Al2O3 (C2M2A14) ternary phases generated from the matrix can greatly increase the cold and hot mechanical strengths. In the case of the no-cement castable, sintering becomes difficult, resulting in a lower mechanical strength.

  2. Desalination of simulated seawater by purge-air pervaporation using an innovative fabricated membrane.

    Science.gov (United States)

    Naim, Mona; Elewa, Mahmoud; El-Shafei, Ahmed; Moneer, Abeer

    2015-01-01

    An innovative polymeric membrane has been invented, which presents a breakthrough in the field of desalination membranes. It can desalinate simulated seawater of exceptionally high concentration to produce a high flux of potable water with over 99.7% salt rejection (%SR) in a once-through purge-air pervaporation (PV) process. A set-up was constructed for conducting the desalination experiments and the effect of initial salt solution concentration (Ci) and pervaporation temperature (Tpv) on the water flux (J), %SR, separation factor, and pervaporation separation index were determined. The membrane was prepared by the phase-inversion technique, of a specially formulated casting solution consisting of five ingredients, after which the membrane was subjected to a post-treatment by which certain properties were conferred. The results confirmed that the salinity of the pervaporate was independent of Ci (all %SR above 99.7). The best result was at Tpv=70 °C, where J varied from 5.97 to 3.45 l/m2 h for Ci=40-140 g NaCl/l, respectively. The membrane morphology was confirmed to be asymmetric. The contact angle was immeasurable, indicating the membrane to be super-hydrophilic. Activation energies computed using Arrhenius law were, under all conditions investigated, less than 20 kJ/mol K.

  3. Automatic heating and cooling system in a gas purge microsyringe extraction.

    Science.gov (United States)

    Piao, Xiangfan; Bi, Jinhu; Yang, Cui; Wang, Xiaoping; Wang, Juan; Li, Donghao

    2011-10-30

    The gas purge microsyringe extraction (GP-MSE) technique offers quantitative and simultaneous extraction, and rapid gas chromatographic-mass spectrometric determination of volatile and semivolatile chemicals is possible. To simplify the application, a new automatic temperature control system was developed here. Stable heating and cooling over a wide range of temperatures were achieved using a micro-heater and thermoelectric cooler under varying gas flow conditions. Temperatures could be accurately controlled in the range 20-350°C (heating) and 20 to -4°C (cooling). Temperature effects on the extraction performance of the GP-MSE were experimentally investigated by comparing the recoveries of polycyclic aromatic hydrocarbons (PAHs) under various experimental conditions. A sample treatment was completed within 3 min, which is much less than the time required for chromatographic analysis. The recovery of chemicals determined ranged from 81 to 96%. High reproducibility data (RSD ≤ 5%) were obtained for direct extraction of various analytes in spiked complex plant and biological samples. The data show that the heating and cooling system has potential applications in GP-MSE system for the direct determination of various kinds of volatile and semivolatile chemicals from complex matrices without any, or only minor, sample pretreatment.

  4. Analysis of ammonia separation from purge gases in microporous hollow fiber membrane contactors.

    Science.gov (United States)

    Karami, M R; Keshavarz, P; Khorram, M; Mehdipour, M

    2013-09-15

    In this study, a mathematical model was developed to analyze the separation of ammonia from the purge gas of ammonia plants using microporous hollow fiber membrane contactors. A numerical procedure was proposed to solve the simultaneous linear and non linear partial differential equations in the liquid, membrane and gas phases for non-wetted or partially wetted conditions. An equation of state was applied in the model instead of Henry's law because of high solubility of ammonia in water. The experimental data of CO₂-water system in the literature was used to validate the model due to the lack of data for ammonia-water system. The model showed that the membrane contactor can separate ammonia very effectively and with recoveries higher than 99%. SEM images demonstrated that ammonia caused some micro-cracks on the surfaces of polypropylene fibers, which could be an indication of partial wetting of membrane in long term applications. However, the model results revealed that the membrane wetting did not have significant effect on the absorption of ammonia because of very high solubility of ammonia in water. It was also found that the effect of gas velocity on the absorption flux was much more than the effect of liquid velocity.

  5. Thermal Spray Using a High-Frequency Pulse Detonation Combustor Operated in the Liquid-Purge Mode

    Science.gov (United States)

    Endo, T.; Obayashi, R.; Tajiri, T.; Kimura, K.; Morohashi, Y.; Johzaki, T.; Matsuoka, K.; Hanafusa, T.; Mizunari, S.

    2016-02-01

    Experiments on thermal spray by pulsed detonations at 150 Hz were conducted. Two types of pulse detonation combustors were used, one operated in the inert gas purge (GAP) mode and the other in the liquid-purge (LIP) mode. In both modes, all gases were supplied in the valveless mode. The GAP mode is free of moving components, although the explosive mixture is unavoidably diluted with the inert gas used for the purge of the hot burned gas. In the LIP mode, pure fuel-oxygen combustion can be realized, although a liquid-droplet injector must be actuated cyclically. The objective of this work was to demonstrate a higher spraying temperature in the LIP mode. First, the temperature of CoNiCrAlY particles heated by pulsed detonations was measured. As a result, the spraying temperature in the LIP mode was higher than that in the GAP mode by about 1000 K. Second, the temperature of yttria-stabilized zirconia (YSZ) particles, whose melting point was almost 2800 °C, heated by pulsed detonations in the LIP mode was measured. As a result, the YSZ particles were heated up to about 2500 °C. Finally, a thermal spray experiment using YSZ particles was conducted, and a coating with low porosity was successfully deposited.

  6. Modeling and simulation of ammonia removal from purge gases of ammonia plants using a catalytic Pd-Ag membrane reactor.

    Science.gov (United States)

    Rahimpour, M R; Asgari, A

    2008-05-01

    In this work, the removal of ammonia from synthesis purge gas of an ammonia plant has been investigated. Since the ammonia decomposition is thermodynamically limited, a membrane reactor is used for complete decomposition. A double pipe catalytic membrane reactor is used to remove ammonia from purge gas. The purge gas is flowing in the reaction side and is converted to hydrogen and nitrogen over nickel-alumina catalyst. The hydrogen is transferred through the Pd-Ag membrane of tube side to the shell side. A mathematical model including conservation of mass in the tube and shell side of reactor is proposed. The proposed model was solved numerically and the effects of different parameters on the rector performance were investigated. The effects of pressure, temperature, flow rate (sweep ratio), membrane thickness and reactor diameter have been investigated in the present study. Increasing ammonia conversion was observed by raising the temperature, sweep ratio and reducing membrane thickness. When the pressure increases, the decomposition is gone toward completion but, at low pressure the ammonia conversion in the outset of reactor is higher than other pressures, but complete destruction of the ammonia cannot be achieved. The proposed model can be used for design of an industrial catalytic membrane reactor for removal of ammonia from ammonia plant and reducing NO(x) emissions.

  7. Needle-type extraction device for the purge and trap analysis of 23 volatile organic compounds in tap water.

    Science.gov (United States)

    Ueta, Ikuo; Razak, Nurhafizza Abd; Mizuguchi, Ayako; Kawakubo, Susumu; Saito, Yoshihiro; Jinno, Kiyokatsu

    2013-11-22

    We developed a rapid determination technique for trace volatile organic compounds (VOCs) in tap water by introducing a novel needle-type extraction device coupled to a purge-and-trap method. To extract a wide range of VOCs, a new extraction needle containing particles of divinylbenzene and activated carbon was developed in this study. During the active sampling of the headspace gas in a glass vial by the extraction needle, pure N2 gas was used for purging the aqueous sample. After the optimization of several experimental parameters, such as the addition of the salt and conditions of dry purging and desorption, the extraction performance of the device and method was evaluated for 23 VOCs that are typically found in tap water samples. The quantification limits of the method were 0.6 μg/L for 1,1-dichloroethylene and less than 0.5 μg/L for other VOCs, with good repeatability being confirmed for all the target compounds. Taking advantage of the excellent recovery of VOCs, the determination of VOCs in real tap water samples was carried out successfully. Because the developed method does not require sample heating and/or cryogenic focusing, simple and rapid analyses can be performed along with satisfactory sensitivity for typical tap water samples.

  8. Temporal change in inbreeding depression in life-history traits in captive populations of guppy (Poecilia reticulata): evidence for purging?

    Science.gov (United States)

    Larsen, L-K; Pélabon, C; Bolstad, G H; Viken, A; Fleming, I A; Rosenqvist, G

    2011-04-01

    Inbreeding depression, which generally affects the fitness of small populations, may be diminished by purging recessive deleterious alleles when inbreeding persists over several generations. Evidence of purging remains rare, especially because of the difficulties of separating the effects of various factors affecting fitness in small populations. We compared the expression of life-history traits in inbred populations of guppy (Poecilia reticulata) with contemporary control populations over 10 generations in captivity. We estimated inbreeding depression as the difference between the two types of populations at each generation. After 10 generations, the inbreeding coefficient reached a maximum value of 0.56 and 0.16 in the inbred and control populations, respectively. Analysing changes in the life-history traits across generations showed that inbreeding depression in clutch size and offspring survival increased during the first four to six generations in the populations from the inbred treatment and subsequently decreased as expected if purging occurred. Inbreeding depression in two other traits was weaker but showed similar changes across generations. The loss of six populations in the inbred treatment indicates that removal of deleterious alleles also occurred by extinction of populations that presumably harboured high genetic load.

  9. Reciprocal associations between negative affect, binge eating, and purging in the natural environment in women with bulimia nervosa.

    Science.gov (United States)

    Lavender, Jason M; Utzinger, Linsey M; Cao, Li; Wonderlich, Stephen A; Engel, Scott G; Mitchell, James E; Crosby, Ross D

    2016-04-01

    Although negative affect (NA) has been identified as a common trigger for bulimic behaviors, findings regarding NA following such behaviors have been mixed. This study examined reciprocal associations between NA and bulimic behaviors using real-time, naturalistic data. Participants were 133 women with bulimia nervosa (BN) according to the 4th edition of the Diagnostic and Statistical Manual of Mental Disorders who completed a 2-week ecological momentary assessment protocol in which they recorded bulimic behaviors and provided multiple daily ratings of NA. A multilevel autoregressive cross-lagged analysis was conducted to examine concurrent, first-order autoregressive, and prospective associations between NA, binge eating, and purging across the day. Results revealed positive concurrent associations between all variables across all time points, as well as numerous autoregressive associations. For prospective associations, higher NA predicted subsequent bulimic symptoms at multiple time points; conversely, binge eating predicted lower NA at multiple time points, and purging predicted higher NA at 1 time point. Several autoregressive and prospective associations were also found between binge eating and purging. This study used a novel approach to examine NA in relation to bulimic symptoms, contributing to the existing literature by directly examining the magnitude of the associations, examining differences in the associations across the day, and controlling for other associations in testing each effect in the model. These findings may have relevance for understanding the etiology and/or maintenance of bulimic symptoms, as well as potentially informing psychological interventions for BN. (c) 2016 APA, all rights reserved).

  10. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  11. 49 CFR 179.500-11 - Loading and unloading valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Loading and unloading valves. 179.500-11 Section...-113 and 107A) § 179.500-11 Loading and unloading valves. (a) Loading and unloading valve or valves shall be mounted on the cover or threaded into the marked end of tank. These valves shall be of...

  12. Segmented ball valve is easy to open and close

    Science.gov (United States)

    Prono, E.; Shinault, L. H.; Speisman, C.

    1966-01-01

    Segmented ball valve and flowmeter in the same spherical housing provide a valve that will handle large fluid volume without bulkiness and weight of blade valves or conventional ball valves. The valve is easily opened or closed and the flowmeter remains stationary, so errors are eliminated.

  13. Transesophageal echocardiography evaluation of tricuspid and pulmonic valves

    Directory of Open Access Journals (Sweden)

    Aneeta Bhatia

    2016-01-01

    Full Text Available The tricuspid is the lost valve and the pulmonary being the most anterior, is not visualized well on TEE; The Pulmonary valve is a semilunar valve that separates the right ventricle from the pulmonary artery. It is situated anterior and superior to the aortic valve, almost at right angle to the aortic valve and parallel to the beam of the ultrasound.

  14. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  15. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  16. Regulation of purine biosynthetic genes expression in Salmonella typhimurium Ⅳ O~c mutation site of purG and its function analysis

    Institute of Scientific and Technical Information of China (English)

    刘奔; 黄谊; 王敖全

    1997-01-01

    Salmonella typhimurium 5 phosphoribosylformylglycinamide (FGAR) amidotransferase encoded by purG gene catalyzes the conversion of FGAR to formylglycinamide ribonucleotide (FGAM) in the presence of glu-tamine and ATP for the de novo purine nucleotide biosynthesis. purG gene is negatively regulated by a repressor-oper-ator system. The O+ purG and OC purG were cloned respectively in vivo. Restriction enzymes analysis of preliminary clones pLBG-1 (O + ) and pLBG-2 (OC) were carried out. The hybrid plasmids pLB1933 (O+ ) and pLB1927 (OC) containing 5 control region of purG were constructed and the DNA sequences were determined respectively. DNA se-quences data showed that Oc mutation of purG occurred at the 3rd position of 16 bp PUR box in the 5’ control region ( G→A). Gel retardation experiment indicated that the repressor bound well with O+ PUR box, but not with Oc PUR box. The result strongly supported the idea that PUR box is the binding region of represser protein and the 3rd posi-tion base G of PUR bo

  17. [Redo Aortic and Mitral Valve Replacement by Manouguian's Procedure for Active Prosthetic Valve Infection].

    Science.gov (United States)

    Kunitomo, Ryuji; Okamoto, Ken; Moriyama, Shuji; Sakaguchi, Hisashi; Tazume, Hirokazu; Yoshinaga, Takashi; Kawasuji, Michio

    2016-03-01

    The damage to the intervalvular fibrous trigone (IVFT) by infective endocarditis makes combined aortic and mitral valve replacement difficult. We performed Manouguian's double valve replacement for such a case and obtained a good result. A 81-year-old male underwent emergency operation due to active prosthetic valve endocarditis. He had a history of receiving combined aortic and mitral valve replacement because of active infective endocarditis at the age of 74 and redo aortic valve replacement 3 years after that. The infectious lesion extended from the mitral annulus to the IVFT and the aortic annulus, and it caused the prosthetic valve detachment from the aortic annulus. Manouguian's double valve replacement was required for radical resection and reconstruction of the IVFT. No recurrent infection or paravalvular leakage was observed during 49months follow up period. Manouguian's procedure is useful for complete resection of the infected IVFT and makes combined aortic and mitral valve replacement safer.

  18. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Hwan [Pusan National University, Busan (Korea, Republic of)

    2009-09-15

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  19. Percutaneous implantation of CoreValve aortic prostheses in patients with a mechanical mitral valve.

    Science.gov (United States)

    Bruschi, Giuseppe; De Marco, Federico; Oreglia, Jacopo; Colombo, Paola; Fratto, Pasquale; Lullo, Francesca; Paino, Roberto; Frigerio, Maria; Martinelli, Luigi; Klugmann, Silvio

    2009-11-01

    Concerns exist in the field of transcatheter aortic valve implantation regarding the treatment of patients with mechanical mitral valve for possible interference between the percutaneous aortic valve and the mechanical mitral prosthesis. We report our experience with percutaneous aortic valve implantation in 4 patients with severe aortic stenosis, previously operated on for mitral valve replacement with a mechanical prosthesis. All patients underwent uneventful percutaneous retrograde CoreValve implantation (CoreValve Inc, Irvine, CA). No deformation of the nitinol tubing of the prostheses (ie, neither distortion nor malfunction of the mechanical valve in the mitral position) occurred in any of the patients. All patients are alive and asymptomatic at a mean follow-up of 171 days.

  20. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  1. 3D Printed Multimaterial Microfluidic Valve

    Science.gov (United States)

    Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics. PMID:27525809

  2. Novel totally implantable trans-ventricular and cross-valvular cannular pump with rolling bearings and purge system for recovery therapy.

    Science.gov (United States)

    Qian, K X; Wang, D F; Topaz, S; Ru, W M; Zeng, P; Yuan, H Y; Zwischenberg, J B

    2007-01-01

    In the early 1990s, Yamazaki et al. developed a partly intra-ventricular pump, which was inserted into the left ventricle via the apex and then into the aorta through the aortic valve. The pump delivered blood flow directly from the left ventricle to the aorta, like a natural heart, and needed no inflow and outflow connecting tubes; it could be weaned off after the left ventricle had been recovered. The shortcomings were that the driving DC motor remained outside of the ventricle, causing an anatomic space problem, and the sealing and bearing were not appropriate for a durable device. Recently, a totally implantable trans-ventricular pump has been developed in the authors' laboratory. The device has a motor and a pump entirely contained within one cannula. The motor has a motor coil with iron core and a rotor with four-pole magnet; the pump has an impeller and an outflow guide vane. The motor part is 60 mm in length and 13 mm in diameter; the pump part is 55 mm in length and 11 mm in diameter. The total length of the device is therefore 115 mm. The total weight of the device is 53 g. The motor uses rolling bearing with eight needles on each side of the rotor magnets. A special purge system is devised for the infusion of saline mixed with heparin through bearing to the pump inlet (30 - 50 cc per hour). Thus neither mechanical wear nor thrombus formation along the bearing will occur. In haemodynamic testing, the pump can produce a flow of 4 l min-1 with 60 mmHg pressure increase, at a pump rotating speed of 12,500 rpm. At zero flow rate, corresponding to the diastolic period of the heart, the pump can maintain aortic blood pressure over 80 mmHg at the same rotating speed. This novel pump can be quickly inserted in an emergency and easily removed after recovery of natural heart. It will be useful for patients with acute left ventricular failure.

  3. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), inclu...... population. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173....

  4. Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.

    Science.gov (United States)

    Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René

    2017-06-01

    Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

  5. Prenatally engineered autologous amniotic fluid stem cell-based heart valves in the fetal circulation.

    Science.gov (United States)

    Weber, Benedikt; Emmert, Maximilian Y; Behr, Luc; Schoenauer, Roman; Brokopp, Chad; Drögemüller, Cord; Modregger, Peter; Stampanoni, Marco; Vats, Divya; Rudin, Markus; Bürzle, Wilfried; Farine, Marc; Mazza, Edoardo; Frauenfelder, Thomas; Zannettino, Andrew C; Zünd, Gregor; Kretschmar, Oliver; Falk, Volkmar; Hoerstrup, Simon P

    2012-06-01

    Prenatal heart valve interventions aiming at the early and systematic correction of congenital cardiac malformations represent a promising treatment option in maternal-fetal care. However, definite fetal valve replacements require growing implants adaptive to fetal and postnatal development. The presented study investigates the fetal implantation of prenatally engineered living autologous cell-based heart valves. Autologous amniotic fluid cells (AFCs) were isolated from pregnant sheep between 122 and 128 days of gestation via transuterine sonographic sampling. Stented trileaflet heart valves were fabricated from biodegradable PGA-P4HB composite matrices (n = 9) and seeded with AFCs in vitro. Within the same intervention, tissue engineered heart valves (TEHVs) and unseeded controls were implanted orthotopically into the pulmonary position using an in-utero closed-heart hybrid approach. The transapical valve deployments were successful in all animals with acute survival of 77.8% of fetuses. TEHV in-vivo functionality was assessed using echocardiography as well as angiography. Fetuses were harvested up to 1 week after implantation representing a birth-relevant gestational age. TEHVs showed in vivo functionality with intact valvular integrity and absence of thrombus formation. The presented approach may serve as an experimental basis for future human prenatal cardiac interventions using fully biodegradable autologous cell-based living materials. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. STUDY ON FLUID THICKNESS BETWEEN POPPET AND VALVE GUIDE IN CONTROL VALVE OF INJECTOR

    Institute of Scientific and Technical Information of China (English)

    Zhang Jianming; Zhang Weigang; Wang Yawei

    2004-01-01

    The physical model of -20 diesel oil and force model of injector control valve of common rail system is built. The changes of the fluid thickness are investigated on the base of the results of CFD and experiments for control valve of injector. The results indicate that a fluid thickness of 0.02~0.03 mm between the poppet and valve guide is sufficient to dampen any excessive control valve poppet bouncing.

  7. An analysis of check valve performance characteristics based on valve design

    Energy Technology Data Exchange (ETDEWEB)

    McElhaney, K.L. [Oak Ridge National Lab., TN (United States). Engineering Technology Div.

    2000-04-01

    Although it had been theorized by nuclear industry valve experts that the two most significant factors in assessing check valve performance were valve type (or design) and operating conditions, until recently, no data was available to support their assumptions. In co-operation with the Nuclear Industry Check Valve Group (NIC), Oak Ridge National Laboratory (ORNL) undertook a review and analysis of check valve failures recorded in the Institute of Nuclear Power Operations' (INPO) Nuclear Plant Reliability Data System (NPRDS). This study involved the characterization of failures according to several parameters, including valve design (e.g. swing check, lift check). Since the valve design is not inherently included within the NPRDS engineering record for each component in the database, ORNL relied on input from NIC, valve manufacturers and catalogs to supply the missing information. As a result, nearly 60% of the 21000 check valves listed in the NPRDS component database and 85% of the 838 failures occurring during 1991-1992 were identified according to valve design. This data provided the basis to perform previously unavailable cross-correlations between parameters such as valve design versus failure mode, valve design versus failure discovery method, population/failure distributions by valve design, etc. Performance assessments and predictions based on more specific sets of parameters (as opposed to generic check valve failure rates obtained from standard reference sources that generally ignore the valve design) should result in a significant impact on future nuclear plant operations, including inservice testing (IST) practices, maintenance, and probabilistic risk assessments (PRAs) by providing a means to calculate more appropriate relative (and ultimately absolute) failure rates for check valves. (orig.)

  8. Improved valve and dash-pot assembly

    Science.gov (United States)

    Chang, S.C.

    1985-04-23

    A dash-pot valve comprises a cylinder submerged in the fluid of a housing and have a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with targentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  9. Valve and dash-pot assembly

    Science.gov (United States)

    Chang, Shih-Chih

    1986-01-01

    A dash-pot valve comprising a cylinder submerged in the fluid of a housing and having a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with tangentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  10. Check valve slam analysis in pumping station

    Science.gov (United States)

    Himr, D.; Habán, V.; Dokoupil, P.

    2016-03-01

    Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.

  11. Low-Pressure-Drop Shutoff Valve

    Science.gov (United States)

    Thornborrow, John

    1994-01-01

    Flapper valve remains open under normal flow conditions but closes upon sudden increases to high rate of flow and remains closed until reset. Valve is fluid/mechanical analog of electrical fuse or circuit breaker. Low-pressure-drop shutoff valve contains flapper machined from cylindrical surface. During normal flow conditions, flapper presents small cross section to flow. (Useful in stopping loss of fluid through leaks in cooling systems.)

  12. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  13. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  14. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  15. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve replacem

  16. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve replacem

  17. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  18. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...

  19. Matching flow characteristics of standard shutoff valves eliminates need for custom fabricated valves

    Science.gov (United States)

    Bevan, A. F.

    1966-01-01

    Standard high pressure valves are used in low pressure fluid system testing when a substantial system pressure increase is required. The flow-vs-valve stroke is matched with that of the valves being replaced. Some correction to the plug contour may be necessary.

  20. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  1. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  2. Repositioning of an Intraventricular Dislocated Aortic Valve during Transcatheter Aortic Valve Implantation

    NARCIS (Netherlands)

    Natour, Ehsan; Douglas, Yvonne L.; Jainandunsing, Jayant S.; Schurer, Remco A. J.; van der Werf, Hendrik W.; van den Heuvel, Ad F. M.

    2014-01-01

    The case is presented of a 75-year-old man referred for transcatheter aortic valve implantation. During the procedure the prosthetic aortic valve became dislocated into the left ventricle shortly after expansion. The subsequent steps taken to reposition the valve using only materials at hand are des

  3. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  4. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  5. Group cognitive behavioral treatment in female soldiers diagnosed with binge/purge eating disorders.

    Science.gov (United States)

    Carter, Rinat; Yanykulovitch-Levy, Dana; Wertheim, Hadas; Gordon-Erez, Shirley; Shahimov, Meital; Weizman, Abraham; Stein, Daniel

    2016-01-01

    Cognitive behavioral treatment (CBT) is the recommended intervention in bulimia nervosa (BN) and eating disorders not otherwise specified with binge/purge (EDNOS-B/P) symptoms. There are fewer data on its application in a group format. We sought to investigate the effect of group CBT in female soldiers with B/P symptomatology in an open trial design. For this purpose we assessed 64 female soldiers serving in the Israeli Defense Force diagnosed with BN and EDNOS-B/P who participated in a group CBT format of 16 weekly sessions and one follow-up session. In this study, 42 participants (65.6%) completed treatment and 22 participants (34.4%) did not. A total of 39 treatment completers (92.8% of treatment completers) and 19 non-completers (86.4% of treatment non-completers) were assessed around 12 months after treatment. Participants completed at baseline and following treatment questionnaires assessing eating-related symptoms, depression, anxiety, and overall functioning. At follow-up they were assessed for eating-related symptoms. Our findings show only minimal baseline differences between treatment completers and non-completers. Significant improvement from baseline to post-treatment was shown for B/P and restrictive symptoms, depression, anxiety, and overall functioning. At that time, more than a third of treatment completers were abstinent from binging and more than a half from vomiting. The improvement in B/P and restricting symptoms was maintained at 1 year follow-up for treatment completers. At that time around 60% were abstinent from binging and more than 70% from vomiting. Participants not completing treatment were also improved at follow-up but to a lesser extent. The findings of the present study suggest that group CBT may be effective for the treatment of female soldiers with BN and EDNOS-B/P.

  6. Purge lecithin for less-expensive diet formulation for black tiger prawn Penaeus monodon

    Directory of Open Access Journals (Sweden)

    Shanmugam Velmurugan

    2010-12-01

    Full Text Available The knowledge of the nutrient requirements and practical diet formulations for Penaeus monodon is fully known. In the production cost, the cost of diet alone comes around 50 to70%. This ismainly because of the addition of lecithin which is a relatively expensive dietary ingredient. It isimportant to determine the usefulness of lecithin in the growth of P. monodon. In order to keep the dietcost as low as possible this experiment was designed with and without lecithin. The objective of thepresent study was to assess the growth of shrimp with varying lecithin doses. To study the water qualityparameters and to study the growth and survival of animals feed containing different percentage oflecithin. Trials conducted indicated the soybean lecithin did not have any effect on shrimp’s growth. Theshrimp weight varied from 3.15 to 8g in Control, 2.58 to 6g in Treatment A, 2.87 to 6.62g in TreatmentB, 3.1 to 6.75g in Treatment C. These confirm that under a controlled clear water culture system, partialor complete replacement of soybean lecithin in a commercial diet for P. monodon resulted in nodetriment in growth. Purge lecithin in the diet may allow for less-expensive diet formulations for P.monodon and may reduce the diet cost for producers, who are supplying feed. As diet cost representsthe largest variable cost in a commercial aquaculture operation, increased knowledge of specific dietaryrequirements is essential for formulating a cost-effective commercial P. monodon diet.

  7. Monitoring of phthalates in foodstuffs using gas purge microsyringe extraction coupled with GC-MS.

    Science.gov (United States)

    He, Miao; Yang, Cui; Geng, Renjie; Zhao, Xiangai; Hong, Lian; Piao, Xiangfan; Chen, Tie; Quinto, Maurizio; Li, Donghao

    2015-06-16

    Phthalate esters (PAEs) are commonly used as nonreactive plasticisers in vinyl plastics to increase the flexibility of plastic polymers. Numerous studies have indicated that the PAEs as a class of endocrine-disrupting chemicals. In addition, the studies have also shown that a major source of human exposure to phthalates is the diet. To date, the largest problem in PAEs analysis is the high blank value because PAEs are widely used in various applications and products. To overcome this shortcoming, gas purge microsyringe extraction (GP-MSE) was applied, which established a new and low-blank-value analytical method for PAE analysis to analyse PAEs in foodstuffs. In this study, GP-MSE was used as a clean-up method, and the overall recoveries ranged from 85.7 to 102.6%, and the RSD was less than 10%. More importantly, this method can overcome the problem of the high blank value in PAE analysis. This method was applied for measuring PAEs in 78 foodstuffs. The results showed that a wide variety of PAE concentrations were found in the different groups, and the content of PAEs (varies from 658 to 1610 ng g(-1) fresh weight) is greatest in seafood. The concentrations were in the following order: DEHP>DBP>DEP≈DMP>BBP≈DNOP. Finally, the daily intake of PAEs was estimated for adults based on the levels of PAEs in foodstuffs. The total EDIdiet values of 3.2 and 12.9 μg kg(-1) bw d(-1) were calculated for DEHP based on the mean and highest concentrations in foodstuffs, respectively.

  8. Improving the pneumatic control valve performance using a PID controller

    OpenAIRE

    Heidari, Mohammad; Homaei, Hadi

    2014-01-01

    Pneumatic control valves are still the most used in process industries due to their low cost and simplicity. This paper presents a design procedure of a PID controller for a pneumatic control valve. For comparison, P and PI controllers are also utilized for the control valve. The bond graph method is used to model the control valve, in order to compare the response characteristics of the valve. Simulation results are found for three controllers of the valve. The integral time absolute error c...

  9. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    Directory of Open Access Journals (Sweden)

    Abulon DJ

    2015-09-01

    Full Text Available Dina Joy Abulon,1 Martin Charles,2 Daniel E Charles21Global Medical Affairs, Alcon Laboratories, Inc., Lake Forest, CA, USA; 2Centro Oftalmológico Dr Charles, Buenos Aires, ArgentinaPurpose: To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP, fluid leakage, and vitreous incarceration during simulated vitrectomy.Methods: Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes.Results: In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005, and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05 and 27-gauge (P<0.05 non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas.Conclusion: Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy.Keywords: IOP, fluid leakage, vitreous incarceration

  10. Serial changes of hemodynamic performance with Medtronic Hall valve in aortic position.

    Science.gov (United States)

    Cho, Yang Hyun; Jeong, Dong Seop; Park, Pyo Won; Park, Kay-Hyun; Sung, Kiick; Kim, Wook Sung; Lee, Young Tak

    2011-02-01

    The aim of this study was to evaluate the long-term hemodynamic performance of the Medtronic Hall valve by analyzing serial changes in echocardiographic outcomes in aortic position. One hundred seventeen patients who underwent aortic valve replacement (AVR) using the Medtronic Hall valve between August 1997 and January 2004 were retrospectively studied. Fifty-five patients underwent isolated AVR (AVR group), and 62 patients underwent AVR and mitral valve replacement (double valve replacement group). Mean age was 51.2 ± 10.4 years (range, 26 to 67 years), and mean follow-up duration was 93.7 ± 25.6 months (913.6 patient-years; range, 17 to 140 months). Serial echocardiographic data were analyzed. Overall mortality was 12.8% (15 of 117), but no early mortality occurred. A greater than 15 mm Hg increment of aortic transprosthetic mean pressure gradient at last follow-up occurred in 13 patients (11.1%). Redo AVR was performed in 7 patients, 6 of whom had subaortic pannus ingrowths. Group cumulative survival rates at 10 years were similar (90.4%, AVR group versus 88.4%, double valve replacement group; p = 0.580), but the AVR group showed better adverse cardiac event-free survival at 10 years (80.1% versus 53.8%; p = 0.025). Multivariate analysis showed that double valve replacement and a small-sized valve (20 mm) significantly predicted the increment of aortic transprosthetic mean pressure gradient at last follow up greater than 15 mm Hg (p = 0.013; odds ratio, 13.9; p = 0.019; odds ratio, 4.2, respectively). The transprosthetic mean pressure gradient of the Medtronic Hall valve in the aortic position frequently increased as a function of time, and this increase was more common in patients who had undergone double valve replacement, especially in those implanted with a small valve. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Transaortic aortic valve replacement using the Edwards Sapien-XT Valve and the Medtronic CoreValve: initial experience.

    Science.gov (United States)

    Spargias, Konstantinos; Bouboulis, Nikolaos; Halapas, Antonios; Chrissoheris, Michael; Skardoutsos, Spyridon; Nikolaou, Joulia; Tsolakis, Apostolos; Mourmouris, Christos; Pattakos, Stratis

    2014-01-01

    Transcatheter aortic valve replacement (TAVR) is now an established treatment for certain patients with severe aortic valve stenosis (AS). However, as the number of patients screened for TAVR increases, many are found to have absolutely no option for peripheral artery access. Transaortic valve replacement (TAoVR) has been proposed as a new alternative route in patients deemed unsuitable for conventional approaches. We present our first series of TAoVR cases using the Edwards Sapien-XT and the Medtronic CoreValve prostheses. Twenty-five (25) symptomatic patients (mean age 78 ± 8 years, mean logistic EuroSCORE I 25 ± 11%) with severe AS underwent TAoVR using the Sapien-XT valve (10 patients) or the CoreValve (15 patients). The mean fluoroscopy time was 15.6 ± 4.2 minutes, the mean time in the intensive care unit was 1.9 ± 1.0 days, and the mean hospital stay was 6.4 ± 1.6 days. The mean effective aortic valve area increased (from 0.68 ± 0.15 cm(2) to 1.82 ± 0.34 cm(2), pMedtronic CoreValve prosthesis demonstrated that it could be performed safely, resulting in substantial acute echocardiographic and early clinical improvement.

  12. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  13. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm.

    Science.gov (United States)

    Tomsic, Anton; Li, Wilson W L; van Paridon, Marieke; Bindraban, Navin R; de Mol, Bas A J M

    2016-08-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred after the aneurysm perforated. The patient showed no signs of heart failure and completed a 6-week regimen of antibiotic therapy before undergoing successful aortic and mitral valve replacement. In addition to the patient's case, we review the relevant medical literature.

  14. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  15. Aortic and Mitral Valve Replacement Through a Single Transverse Aortotomy: A Useful Approach in Difficult Mitral Valve Exposure

    OpenAIRE

    Carmichael, Michael J.; Cooley, Denton A.; Favor, Arsenio S.

    1983-01-01

    Replacement of the mitral valve through a standard vertical left atriotomy in patients requiring both aortic and mitral valve replacement can be very difficult. This is especially true in patients who have undergone previous median sternotomy. Replacement of the mitral valve through the aortic root after excision of the aortic valve is described in two case reports. This is a convenient approach when traditional exposure of the mitral valve is impractical in patients requiring double valve re...

  16. Disruption of silicone valve housing in a Codman Hakim Precision valve with integrated Siphonguard.

    Science.gov (United States)

    Woerdeman, Peter A; Cochrane, David D

    2014-05-01

    Authors of this report describe 2 patients who had undergone shunt insertion for hydrocephalus and who, at 6 weeks or 9 months after their last revision, presented with symptoms of shunt dysfunction and CSF collections at the valve site. At the ensuing shunt revision in both patients, the silicone housing was fractured and the Siphonguard was disconnected from the Codman Hakim Precision flat-bottom valve. The cause of these failures was not clear since manipulation, bending, and twisting of the valves were not thought to have occurred during implantation. A review of the FDA's Manufacturer and User Facility Device Experience (MAUDE) database revealed 58 cases of silicone housing failure in the Codman Hakim Precision valve with integrated Siphonguard since the year 2000. A single report was found in the databases administered by the Canadian Medical Devices Sentinel Network (CMDSNet). The Codman Hakim Precision valves with integrated Siphonguard are delicate devices that do not withstand the intraoperative handling tolerated by other valves. When these valves are implanted, gentle handling and wide exposures are needed to minimize the risk of valve damage. Valves should be handled according to the manufacturer's instructions. However, in light of this particular pattern of failure, it is recommended that the manufacturer redesign this valve to provide handling tolerance that is characteristic of other valves on the market. The featured cases illustrate the importance of the surgeon's role in postmarket surveillance of medical devices and reporting device failures to the responsible agencies and manufacturers.

  17. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  18. Left atrial ball valve thrombus

    Directory of Open Access Journals (Sweden)

    R. Balaji

    2013-10-01

    Full Text Available "Ball valve thrombus" which is a spherical free floating clot in left atrium is an often quoted, but uncommonly encountered complication in patients with severe mitral stenosis of rheumatic origin, who are in atrial fibrillation. We describe the case of a 31-year-old lady with rheumatic heart disease, severe mitral stenosis and moderately severe aortic stenosis who had undergone closed mitral valvotomy 13 years ago. The patient presented with an episode of non-exertional syncope and breathlessness on exertion of 6 months duration and was in normal sinus rhythm. Echocardiography facilitated ante-mortem diagnosis and prompt institution of surgery was life saving.

  19. On-pump fibrillating heart mitral valve replacement with the SAPIEN™ XT transcatheter heart valve.

    Science.gov (United States)

    Ferrari, Enrico; Niclauss, Lars; Locca, Didier; Marcucci, Carlo

    2014-04-01

    In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien™ XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.

  20. Predictors of mortality after aortic valve replacement

    NARCIS (Netherlands)

    Tjang, Yanto Sandy; van Hees, Yvonne; Koerfer, Reiner; Grobbee, Diederick E.; van der Heijden, Geert J. M. G.

    Aortic valve replacement (AVR) is recommended as a standard surgical procedure for aortic valve disease. Still the evidence for commonly claimed predictors of post-AVR prognosis, in particular mortality, appears scant. This systematic review reports on the evidence for predictors of post-AVR

  1. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  2. 49 CFR 195.420 - Valve maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each...

  3. A highly sensitive spin-valve transistor

    NARCIS (Netherlands)

    Erve, van 't O.M.J.; Vlutters, R.; Anil Kumar, P.S.; Kim, S.D.; Jansen, R.; Lodder, J.C.; Hadjipanayis, G.C.

    2001-01-01

    In this paper we present a spin-valve transistor made with a silicon on insulator wafer as emitter and a double sided polished Si wafer as collector. Using vacuum metal bonding we obtain a three terminal device in which a spin-valve layer is sandwiched between two Si wafers. We measure a 217% change

  4. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature.

  5. 46 CFR 64.67 - Shutoff valve.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Shutoff valve. 64.67 Section 64.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.67 Shutoff valve. A shutoff...

  6. Digital hydraulic valving system. [design and development

    Science.gov (United States)

    1973-01-01

    The design and development are reported of a digital hydraulic valving system that would accept direct digital inputs. Topics include: summary of contractual accomplishments, design and function description, valve parameters and calculations, conclusions, and recommendations. The electrical control circuit operating procedure is outlined in an appendix.

  7. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  8. Inexpensive tamper proof safety relief valve

    Science.gov (United States)

    Frankewich, P. A.

    1970-01-01

    Basic relief valve has added safety relief valve capability that relieves overpressure before failure can occur. It may be installed in inaccesible areas with a high degree of reliability, constructed from a variety of materials, and adapted to the user's specific application.

  9. Heart Valve Disease among Patients with Hyperprolactinaemia

    DEFF Research Database (Denmark)

    Steffensen, Charlotte; Maegbaek, Merete Lund; Laurberg, Peter;

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  10. Mitral valve disease—morphology and mechanisms

    Science.gov (United States)

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  11. Mitral valve disease--morphology and mechanisms.

    Science.gov (United States)

    Levine, Robert A; Hagége, Albert A; Judge, Daniel P; Padala, Muralidhar; Dal-Bianco, Jacob P; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H; Clusel, Catherine; Delling, Francesca N; Dietz, Harry C; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D; Jensen, Morten O; Jeunemaitre, Xavier P; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R; Mérot, Jean; Messas, Emmanuel; Milan, David P; Neri, Tui; Norris, Russell A; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A; Song, Jae-Kwan; Yacoub, Magdi H

    2015-12-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.

  12. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan;

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  13. Repair for acquired aortic valve disease.

    Science.gov (United States)

    Antunes, M J

    1996-10-01

    The favorable results of mitral valvuloplasty when compared with valve replacement have renewed the interest of many surgeons in aortic valve repair. However, these efforts have, for the most part, been unsuccessful. Also, the results of aortic valve replacement are usually better than those of mitral valve replacement. Yet, some patients appear to derive benefit from a conservative aortic valve procedure. The best examples are mild or moderate aortic valve disease associated with mitral valve or coronary artery disease, which constitute the primary indication for operation, where "prophylactic" aortic valve replacement does not appear justifiable. Other possible indications for aortic valvuloplasty includes patient's lack of compliance or contraindication to anticoagulation in young patients. Senile aortic stenosis, in very old patients with a small annulus, preserved leaflet morphology and nonsignificant commissural fusion should be considered for repair. However, since the procedure is not easily reproducible and the results not uniformly predictable, it cannot be recommended for generalized use. Nonetheless, experienced surgeons should be encouraged to continue these efforts.

  14. [Surgical Treatment of Prosthetic Valve Endocarditis].

    Science.gov (United States)

    Kaminishi, Yuichiro; Akutsu, Hirohiko; Sugaya, Akira; Kurumisawa, Soki; Takazawa, Ippei; Sato, Hirotaka; Muraoka, Arata; Aizawa, Kei; Ohki, Shinichi; Saito, Tsutomu; Kawahito, Koji; Misawa, Yoshio

    2015-11-01

    Between 2003 and 2014, at Jichi Medical University Hospital, 11 patients with prosthetic valve endocarditis (PVE) underwent re-operation. There was 1 in-hospital death and 2 late deaths. The cause of death was cirrhosis, heart failure and sepsis, respectively. Emergency surgery, previous double valve replacement (DVR) and Staphylococcus infection were common risk factors for all 3 cases. Two cases of patients that survived who underwent mitral valve replacement (MVR) and DVR for PVE after DVR were treated with multiple antibiotic courses for bacteremia associated with hemodialysis and colon cancer. One patient who underwent DVR after mitral valve plasty which was complicated with cerebral hemorrhage, had survived and was discharged. Of the aortic PVE patients, 2 cases of aortic valve replacement (AVR) using a mechanical valve, 1 case of aortic root replacement (ARR) using a mechanical valve, and 1 ARR using the homograft, were considered cured and never relapsed. A patient with aortic PVE, who underwent AVR after cesarean section for heart failure in birth period, has received ARR twice with the mechanical valve for recurrent pseudo-aneurysm of the left ventricular outflow tract. Since hemodialysis and colon cancer is a risk factor for recurrent PVE, it is necessary to consider the long-term administration of antibiotics after surgery.

  15. Tubular hypoplasia of the aorta and right atrioventricular valve dysplasia in a Bulldog.

    Science.gov (United States)

    Robinson, Nicholas A; Armíen, Aníbal G

    2010-07-01

    A Bulldog puppy that died at 1 day of age was presented for postmortem evaluation. Macroscopically, there was marked hypoplasia of the ascending, transverse, and proximal segments of the descending thoracic aorta and almost complete secondary thrombosis of the left ventricle causing a functional stenosis of the left atrioventricular valve. Separately, there was right atrioventricular valve dysplasia with secondary dilation of the right atrium. Microscopically, the left ventricular outflow tract was occluded by chondroid metaplasia, fibrosing recanalization of a left-ventricular thrombus, and isolated Purkinje fiber degeneration and necrosis.

  16. Transcatheter aortic valve replacement in elderly patients

    Institute of Scientific and Technical Information of China (English)

    Dimytri Siqueira; Alexandre Abizaid; Magaly Arrais J.; Eduardo Sousa

    2012-01-01

    Aortic stenosis is the most common native valve disease, affecting up to 5% of the elderly population. Surgical aortic valve replacement reduces symptoms and improves survival, and is the definitive therapy in patients with symptomatic severe aortic stenosis. However, despite the good results of classic surgery, risk is markedly increased in elderly patients with co-morbidities. Transcatheter aortic valve replacement (TAVR) allows implantation of a prosthetic heart valve within the diseased native aortic valve without the need for open heart surgery and cardiopulmonary bypass, offering a new therapeutic option to elderly patients considered at high surgical risk or with contraindications to surgery. To date, several multicenter registries and a randomized trial have confirmed the safety and efficacy of TAVR in those patients. In this chapter, we review the background and clinical applications of TAVR in elderly patients.

  17. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  18. [Interventional mitral valve replacement. Current status].

    Science.gov (United States)

    Lutter, G; Frank, D

    2016-02-01

    Approximately 30 % of patients suffering from severe valvular heart disease, such as mitral valve regurgitation are non-compliant to the gold standard of minimally invasive surgery, reconstruction or valve replacement. The number of these mostly old patients with severe comorbidities is increasing; therefore, transcatheter interventions have been developed to address an unmet clinical need and may be an alternative therapeutic option to the reference standard. Apart from the successful MitraClip therapy, alternative transcatheter reconstruction technologies are being developed. As with transcatheter aortic valve implantation (TAVI) procedures, the off-pump implantation of a valved stent into the mitral position mainly via a transapical approach will be of great benefit. Recently, the feasibility of transcatheter mitral valved stent implantation in high-risk patients has already been reported.

  19. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  20. Multidisciplinary optimization of a butterfly valve.

    Science.gov (United States)

    Song, Xue Guan; Wang, Lin; Baek, Seok Heum; Park, Young Chul

    2009-07-01

    A butterfly valve is a type of flow control device, typically used to regulate fluid flow. This paper proposes a new process to meet desired needs in valve design that is characterized by the complex configuration. First, the need is identified according to the valve user/company, and then the problem is defined with a characteristic function. Second, the initial model of valve is made, and then the initial analysis including fluid and/or structural analysis is carried out to predict the fluid and/or structural performance of the valve. Third, the optimization in the form of mathematical functions, which considers single or multiple objective and/or discipline, is handled. This part includes the design of computer experiment, approximation technique, topology optimization and sizing optimization. Finally, the validation experiment is conducted based on the optimum result to verify the accuracy of the optimization. An example is provided to confirm the availability of the process proposed here.