  1. Pulsed dose rate brachytherapy – is it the right way?

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2010-10-01

    Full Text Available Pulsed dose rate (PDR-BT treatment is a brachytherapy modality that combines physical advantages of high-doserate (HDR-BT technology (isodose optimization, radiation safety with the radiobiological advantages of low-dose-rate (LDR-BT brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in every hour to approximately the same total dose in the sameoverall time as with the LDR-BT. Modern afterloading equipment offers certain advantages over interstitial or intracavitaryinsertion of separate needles, tubes, seeds or wires. Isodose volumes in tissues can be created flexibly by a combinationof careful placement of the catheter and the adjustment of the dwell times of the computerized stepping source.Automatic removal of the radiation sources into a shielded safe eliminates radiation exposures to staff and visitors.Radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes etc. This review based on summarized clinical investigations, analyses the feasibility and the background to introduce this brachytherapy technique and chosen clinical applications of PDR-BT.

  2. Pulsed dose rate brachytherapy (PDR): an analysis of the technique at 2 years

    Energy Technology Data Exchange (ETDEWEB)

    Thienpont, M. [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde; Van Eijkeren, M.; Van Hecke, H.; Boterberg, T.; De Neve, W.

    1995-12-01

    A total of 154 applications was analysed using a pulsed dose brachytherapy technique for 138 patients over a 2 year period with emphasis on technical aspects influencing the overall treatment time. Vaginal ovoids were used in 59 cases, plastic tubes in 52, a Fletcher-type in 18, vaginal cylinders in 14 and a perineal template in 11 cases. Pulses were given at hourly intervals with a median dose rate of 0.6 Gy per pulse (range 0.4 to 3 Gy). The number of pulses per application varied from 3 to 134 (median 32). The number of dwell positions varied from 1 to 542 over 1 to 18 catheters. Patient related problems were few. The room was entered almost every 77 minutes. We noted 561 status codes in 147 applications. Of the 25 different codes, the most frequent one was due to the door left open when a pulse had to be given (35%) or due to constriction of the plastic catheters at the transfer tube junction (26%). However, the median total treatment time was increased by only 5 minutes. With pulsed dose rate brachytherapy at hourly pulses we can treat our patients within the planned time despite frequent room entrance and occurrence of an appreciable number of status codes. This technique seems to fulfill its promise to replace low dose rate brachytherapy.

  3. A review of the clinical experience in pulsed dose rate brachytherapy.

    Science.gov (United States)

    Balgobind, Brian V; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R N; Pieters, Bradley R

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in different tumour locations. We found 66 articles reporting on clinical PDR brachytherapy including the treatment procedure and outcome. Moreover, PDR brachytherapy has been applied in almost all tumour sites for which brachytherapy is indicated and with good local control and low toxicity. The main advantage of PDR is, because of the small pulse sizes used, the ability to spare normal tissue. In certain cases, HDR resembles PDR brachytherapy by the use of multifractionated low-fraction dose.

  4. Pulsed-dose-rate and low-dose-rate brachytherapy : Comparison of sparing effects in cells of a radiosensitive and a radioresistant cell line

    NARCIS (Netherlands)

    Pomp, J; Woudstra, EC; Kampinga, HH

    Pulsed-dose-rate regimens are an attractive alternative to continuous low-dose-rate brachytherapy. However, apart from data obtained from modeling, only a few irt vitro results are available for comparing the biological effectiveness of both modalities. Cells of two human cell lines with survival

  5. Pulsed-Dose Rate Brachytherapy for the Treatment of Endometrial Cancer.

    Science.gov (United States)

    De Felice, Francesca; Caiazzo, Rossella; Benevento, Ilaria; Musio, Daniela; Rubini, Filippo; Tombolini, Vincenzo

    2017-01-01

    Endometrial cancer (EC) is the most frequent gynecologic malignancy. The aim of this review is to outline clinical practice recommendations, to suggest a technical solution, and to advise doses selection for pulsed-dose rate (PDR) brachytherapy in EC. Electronic bibliographic databases, including PubMed, clinicaltrials.gov, and the American Society of Clinical Oncology (ASCO) Meeting Library, were searched for articles in English. Clinical guidelines and systematic reviews were also considered. The appropriate therapeutic approach should consider risk factors for tumor relapse and PDR brachytherapy and have a convincing role in this multidisciplinary scenario. Performing PDR brachytherapy in EC requires robust training and experience. © 2017 S. Karger AG, Basel.

  6. Film dosimetry calibration method for pulsed-dose-rate brachytherapy with an 192Ir source.

    Science.gov (United States)

    Schwob, Nathan; Orion, Itzhak

    2007-05-01

    192Ir sources have been widely used in clinical brachytherapy. An important challenge is to perform dosimetric measurements close to the source despite the steep dose gradient. The common, inexpensive silver halide film is a classic two-dimensional integrator dosimeter and would be an attractive solution for these dose measurements. The main disadvantage of film dosimetry is the film response to the low-energy photon. Since the photon energy spectrum is known to vary with depth, the sensitometric curves are expected to be dependent on depth. The purpose of this study is to suggest a correction method for silver halide film dosimetry that overcomes the response changes at different depths. Sensitometric curves have been obtained at different depths with verification film near a 1 Ci 192Ir pulsed-dose-rate source. The depth dependence of the film response was observed and a correction function was established. The suitability of the method was tested through measurement of the radial dose profile and radial dose function. The results were compared to Monte Carlo-simulated values according to the TG43 formalism. Monte Carlo simulations were performed separately for the beta and gamma source emissions, using the EGS4 code system, including the low-energy photon and electron transport optimization procedures. The beta source emission simulation showed that the beta dose contribution could be neglected and therefore the film-depth dependence could not be attributed to this part of the source radioactivity. The gamma source emission simulations included photon-spectra collection at several depths. The results showed a depth-dependent softening of the photon spectrum that can explain the film-energy dependence.

  7. Preliminary report of pulsed dose rate brachytherapy in head-and-neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ziemlewski, A.; Zienkiewicz, J. [Medical Univ. of Gdansk (Poland). Dept. of Oral and Maxillofacial Surgery; Serkies, K.; Badzio, A. [Medical Univ. of Gdansk (Poland). Dept. of Oncology and Radiotherapy

    2007-09-15

    Purpose: To assess the feasibility and acute/delayed toxicity of pulsed-dose-rate brachytherapy (PDR BT) in head-and-neck tumors. Patients and Methods: 45 head and neck cancer patients underwent interstitial or contact PDR BT at a dose of 10.2-70 Gy (median, 70 Gy) and 0.6 or 1.0 Gy/pulse/h. 42 patients were administered BT as part of their curative treatment; 32 of them had sole BT. Three reirradiated patients with recurrent tumor had palliative BT. Results: PDR BT was well tolerated. Intense bleeding was the only complication associated with catheter removal from the tongue and bucca. 44 patients who completed BT experienced acute mucositis. Grade 3 toxicity of skin and oral mucosa occurred in three (6.8%) and six patients (13.6%), respectively. At a median follow-up of 22 months (range, 2-67 months), late serious toxicity (grade 4, for soft tissue and bone) was seen in seven patients (15.9%). Among the parameters analyzed, only dental care performed before BT had a significant impact on mucosal side effects. Acute severe mucositis was observed in 23% of patients without dental care compared to 0% of those with dental care (p = 0.044). Late severe mucositis occurred in 17.7% and 26.9% of the respective patients (p = 0.035), overall in 23%. The larger the volume encompassed by the reference isodose, the more late (p = 0.004) mucosal reactions were observed. Conclusion: PDR BT continued over a few days is a feasible and safe approach in head-and-neck tumors; however, it is accompanied by some toxicity. Dental care should precede isotope application. (orig.)

  8. A two-dose-rate method for general recombination correction for liquid ionization chambers in pulsed beams

    Energy Technology Data Exchange (ETDEWEB)

    Toelli, Heikki; Sjoegren, Rickard; Wendelsten, Mikael, E-mail: heikki.tolli@radfys.umu.s [Department of Radiation Sciences, Radiation Physics, Umeaa University, SE-901 85 Umeaa (Sweden)

    2010-08-07

    The correction for general recombination losses in liquid ionization chambers (LICs) is more complex than that in air-filled ionization chambers. The reason for this is that the saturation charge in LICs, i.e. the charge that escapes initial recombination, depends on the applied voltage. This paper presents a method, based on measurements at two different dose rates in a pulsed beam, for general recombination correction in LICs. The Boag theory for pulsed beams is used and the collection efficiency is determined by numerical methods which are equivalent to the two-voltage method used in dosimetry with air-filled ionization chambers. The method has been tested in experiments in water in a 20 MeV electron beam using two LICs filled with isooctane and tetramethylsilane. The dose per pulse in the electron beam was varied between 0.1 mGy/pulse and 8 mGy/pulse. The relative standard deviations of the collection efficiencies determined with the two-dose-rate method ranged between 0.1% and 1.5%. The dose-rate variations of the general recombination corrected charge measured with the LICs are in excellent agreement with the corresponding values obtained with an air-filled plane parallel ionization chamber.

  9. SU-E-T-34: An in Vivo Study On Pulsed Low Dose-Rate Radiotherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, B; Cvetkovic, D; Chen, L; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Chen, X [Fox Chase Cancer Center, Philadelphia, PA (United States); Virtua Fox Chase Cancer Center, Voorhees, NJ (United States); Zhang, P [Fox Chase Cancer Center, Philadelphia, PA (United States); Sichuan Cancer Hospital, Chengdu (China); Zhang, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Qiqihar Medical University, Qiqihar (China)

    2014-06-01

    Purpose: Re-irradiation with conventional radiotherapy techniques (CRT) may pose significant risks due to high accumulative radiation doses. Pulsed low dose-rate radiotherapy (PLDR) has been used in clinical trials for recurrent cancer treatment. In our previous studies, PLDR irradiation showed significantly lower toxicity than CRT, resulting in much longer survival of mice after PLDR total body irradiation (TBI) than conventional TBI. The purpose of this study was to investigate tumor control efficacy of PLDR treatment for prostate cancer with an animal model of prostate cancer LNCaP. Methods: We used an orthotopic murine model of LNCaP cell line for this study. LNCaP cells were implanted into immune-suppressed male nude mice via surgery. We monitored the tumor growth with MRI. The tumor-bearing mice were allocated into a PLDR(n=9), CRT(n=7), and control group(n=7) randomly. The mice in the PLDR and CRT groups were irradiated with 2Gy dose for one time. For the CRT treatment, the mice received 2Gy at a dose-rate of 300 MU/minute. For the PLDR treatment, the 2Gy dose was further divided into ten pulses of 0.2Gy at the same dose-rate with an interval of 3 minutes between the pulses. Results: Sizable tumor growth delays were observed for the PLDR and CRT groups through weekly MRI scans. The mean values of the normalized tumor volumes (± standard deviation of the mean) were 1.53±0.07, 1.53±0.14, and 1.81±0.09 at one week after treatment, 2.28±0.13, 2.19±0.16, and 3.04±0.25 at two weeks after treatment, and 3.31±0.23, 3.14±0.24 and 4.62±0.49 at three weeks after treatment, for the PLDR, CRT, and control groups, respectively. Conclusion: The PLDR and CRT treatments showed comparable tumor control rates in this study. Our in vivo results indicate that PLDR may be a viable option for treating recurrent prostate cancer due to its equivalent tumor control but low normal tissue toxocities.

  10. Achieving a Linear Dose Rate Response in Pulse-Mode Silicon Photodiode Scintillation Detectors Over a Wide Range of Excitations

    Science.gov (United States)

    Carroll, Lewis

    2014-02-01

    We are developing a new dose calibrator for nuclear pharmacies that can measure radioactivity in a vial or syringe without handling it directly or removing it from its transport shield “pig”. The calibrator's detector comprises twin opposing scintillating crystals coupled to Si photodiodes and current-amplifying trans-resistance amplifiers. Such a scheme is inherently linear with respect to dose rate over a wide range of radiation intensities, but accuracy at low activity levels may be impaired, beyond the effects of meager photon statistics, by baseline fluctuation and drift inevitably present in high-gain, current-mode photodiode amplifiers. The work described here is motivated by our desire to enhance accuracy at low excitations while maintaining linearity at high excitations. Thus, we are also evaluating a novel “pulse-mode” analog signal processing scheme that employs a linear threshold discriminator to virtually eliminate baseline fluctuation and drift. We will show the results of a side-by-side comparison of current-mode versus pulse-mode signal processing schemes, including perturbing factors affecting linearity and accuracy at very low and very high excitations. Bench testing over a wide range of excitations is done using a Poisson random pulse generator plus an LED light source to simulate excitations up to ˜106 detected counts per second without the need to handle and store large amounts of radioactive material.

  11. Investigations of DNA damage induction and repair resulting from cellular exposure to high dose-rate pulsed proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Renis, M.; Malfa, G.; Tomasello, B. [Drug Sciences Department, University of Catania, Catania (Italy); Borghesi, M.; Schettino, G. [Queen' s University Belfast, Northern Ireland (United Kingdom); Favetta, M.; Romano, F.; Cirrone, G. A. P. [National Institute for Nuclear Physics (INFN-LNS), Catania (Italy); Manti, L. [Physics Science Department, University of Naples Federico II, Naples, and National Institute for Nuclear Physics (INFN), Naples (Italy)

    2013-07-26

    Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/μm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately

  12. Dose-rate effects in GaAs investigated by discrete pulsed implantation using a focused ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Musil, C.R.; Melngailis, J.; Etchin, S. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Haynes, T.E. [Solid State Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    1996-10-01

    The dependence of the retained lattice damage upon dose rate was investigated by focused ion beam (FIB) implantation of 210 keV Si{sup ++} into GaAs at room temperature. The as-implanted and postannealed states were characterized by ion channeling and Hall-effect measurements, respectively. Dose-rate effects arise from stabilizing interactions between populations of defects produced by different ions, and these experiments were designed to probe the time constants of those interactions. In the context of dose-rate experiments, direct-write FIB represents a much more controllable means of implantation over conventional broad beams since the exact timing of dose delivery may be precisely defined and varied. In this work, the final implanted dose was achieved by the successive application of individual flux pulses of constant intensity but of varying duration {ital t}{sub {ital d}} and repetition period {ital t}{sub {ital r}}. A consistent trend toward a greater concentration of displaced atoms directly after implantation and a higher sheet resistance after annealing was observed for longer {ital t}{sub {ital d}} and for shorter {ital t}{sub {ital r}}. This effect did not manifest itself simply in terms of the average current density, {ital J}{sub avg}{proportional_to}{ital t}{sub {ital d}}/{ital t}{sub {ital r}}. Furthermore, it was observed on all time scales accessible in this experiment, suggesting that the important self-annealing mechanisms have a wide range of time constants, from less than 1 {mu}s to more than 1 s. A heterogeneous model of damage nucleation is discussed whereby the defect track of an individual ion event self-anneals until it is overlapped by a following event. {copyright} {ital 1996 American Institute of Physics.}

  13. Local Tumor Control and Normal Tissue Toxicity of Pulsed Low-Dose Rate Radiotherapy for Recurrent Lung Cancer

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2015-05-01

    Full Text Available Objectives: This study investigates (1 local tumor control and (2 normal tissue toxicity of pulsed low-dose rate radiotherapy (PLDR for recurrent lung cancer. Methods: For study 1, nude mice were implanted with A549 tumors and divided into the following 3 groups: (1 control (n = 10, (2 conventional radiotherapy (RT; n = 10, and (3 PLDR (n = 10. Tumor-bearing mice received 2 Gy daily dose for 2 consecutive days. Weekly magnetic resonance imaging was used for tumor growth monitoring. For study 2, 20 mice received 8 Gy total body irradiation either continuously (n = 10 or 40 × 0.2 Gy pulses with 3-minute intervals (n = 10. Results: For study 1, both conventional RT and PLDR significantly inhibited the growth of A549 xenografts compared with the control group (>35% difference in the mean tumor volume; P .05. For study 2, the average weight was 20.94 ± 1.68 g and 25.69 ± 1.27 g and the survival time was 8 days and 12 days for mice treated with conventional RT and PLDR (P < .05, respectively. Conclusion: This study showed that PLDR could control A549 tumors as effectively as conventional RT, and PLDR induced much less normal tissue toxicity than conventional RT. Thus, PLDR would be a good modality for recurrent lung cancers. Advances in Knowledge: This article reports our results of an in vivo animal investigation of PLDR for the treatment of recurrent cancers, which may not be eligible for treatment because of the dose limitations on nearby healthy organs that have been irradiated in previous treatments. This was the first in vivo study to quantify the tumor control and normal tissue toxicities of PLDR using mice with implanted tumors, and our findings provided evidence to support the clinical trials that employ PLDR treatment techniques.

  14. Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    Science.gov (United States)

    Virelli, A; Zironi, I; Pasi, F; Ceccolini, E; Nano, R; Facoetti, A; Gavoçi, E; Fiore, M R; Rocchi, F; Mostacci, D; Cucchi, G; Castellani, G; Sumini, M; Orecchia, R

    2015-09-01

    A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses on a human glioblastoma cell line (T98G). Cell proliferation rate and potassium outward currents (IK) have been investigated by time lapse imaging and patch clamp recordings. The results showed that PFMA-3 irradiation has a greater capability to reduce the proliferation rate activity with respect to XRT, while it does not affect IK of T98G cells at any of the dose levels tested. XRT irradiation significantly reduces the mean IK amplitude of T98G cells only at 0.5 Gy. This work confirms that the DR, and therefore the source of radiation, is crucial for the planning and optimisation of radiotherapy applications.

  15. Reirradiation for recurrent head and neck cancer with salvage interstitial pulsed-dose-rate brachytherapy. Long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Strnad, Vratislav; Lotter, Michael; Kreppner, Stephan; Fietkau, Rainer [University Hospital Erlangen, Dept. of Radiation Oncology, Erlangen (Germany)

    2015-01-10

    To assess the long-term results of protocol-based interstitial pulsed-dose-rate (PDR) brachytherapy as reirradiation combined with simultaneous chemotherapy and interstitial hyperthermia in selected patients with recurrent head and neck tumors. A total of 104 patients with biopsy-proven recurrent head and neck cancer were treated with interstitial PDR brachytherapy. Salvage surgery had also been undergone by 53/104 (51 %) patients (R1 or R2 resection in > 80 % of patients). Salvage brachytherapy alone was administered in 81 patients (78 %), with a median total dose of 56.7 Gy. Salvage brachytherapy in combination with external beam radiotherapy (EBRT) was performed in 23/104 patients (32 %), using a median total dose of D{sub REF} = 24 Gy. Simultaneously to PDR brachytherapy, concomitant chemotherapy was administered in 58/104 (55.8 %) patients. A single session of interstitial hyperthermia was also used to treat 33/104 (31.7 %) patients. The analysis was performed after a median follow-up of 60 months. Calculated according to Kaplan-Meier, local tumor control rates after 2, 5, and 10 years were 92.5, 82.4, and 58.9 %, respectively. Comparing results of salvage PDR brachytherapy with or without simultaneous chemotherapy, the 10-year local control rates were 76 vs. 39 % (p= 0014), respectively. No other patient- or treatment-related parameters had a significant influence on treatment results. Soft tissue necrosis or bone necrosis developed in 18/104 (17.3 %) and 11/104 (9.6 %) patients, respectively, but only 3 % of patients required surgical treatment. PDR interstitial brachytherapy with simultaneous chemotherapy is a very effective and, in experienced hands, also a safe treatment modality in selected patients with head and neck cancer in previously irradiated areas. (orig.) [German] Es erfolgte die Analyse der Langzeitergebnisse einer protokollbasierten interstitiellen Brachytherapie (Re-Bestrahlung) mit simultaner Chemotherapie und interstitieller Hyperthermie

  16. Pulsed-dose-rate peri-operative brachytherapy as an interstitial boost in organ-sparing treatment of breast cancer

    Science.gov (United States)

    Jaśkiewicz, Janusz; Dziadziuszko, Rafał; Jassem, Jacek

    2016-01-01

    Purpose To evaluate peri-operative multicatheter interstitial pulsed-dose-rate brachytherapy (PDR-BT) with an intra-operative catheter placement to boost the tumor excision site in breast cancer patients treated conservatively. Material and methods Between May 2002 and October 2008, 96 consecutive T1-3N0-2M0 breast cancer patients underwent breast-conserving therapy (BCT) including peri-operative PDR-BT boost, followed by whole breast external beam radiotherapy (WBRT). The BT dose of 15 Gy (1 Gy/pulse/h) was given on the following day after surgery. Results No increased bleeding or delayed wound healing related to the implants were observed. The only side effects included one case of temporary peri-operative breast infection and 3 cases of fat necrosis, both early and late. In 11 patients (11.4%), subsequent WBRT was omitted owing to the final pathology findings. These included eight patients who underwent mastectomy due to multiple adverse prognostic pathological features, one case of lobular carcinoma in situ, and two cases with no malignant tumor. With a median follow-up of 12 years (range: 7-14 years), among 85 patients who completed BCT, there was one ipsilateral breast tumor and one locoregional nodal recurrence. Six patients developed distant metastases and one was diagnosed with angiosarcoma within irradiated breast. The actuarial 5- and 10-year disease free survival was 90% (95% CI: 84-96%) and 87% (95% CI: 80-94%), respectively, for the patients with invasive breast cancer, and 91% (95% CI: 84-97%) and 89% (95% CI: 82-96%), respectively, for patients who completed BCT. Good cosmetic outcome by self-assessment was achieved in 58 out of 64 (91%) evaluable patients. Conclusions Peri-operative PDR-BT boost with intra-operative tube placement followed by EBRT is feasible and devoid of considerable toxicity, and provides excellent long-term local control. However, this strategy necessitates careful patient selection and histological confirmation of primary

  17. SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

    Energy Technology Data Exchange (ETDEWEB)

    Cvetkovic, D; Zhang, P; Wang, B; Chen, L; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-01

    Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

  18. SU-E-T-620: Planning and Dosimetry for Pulsed Low Dose Rate RT for Recurrent Lung, Spine, GYN and Head and Neck Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Tong, X; Luo, F; Liu, Y; Zhang, W; Xu, Q; Zhang, T; Li, J [3rd Affiliated Hospital of Qiqihar Medical University, Qiqihar (China); Chen, L; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Extensive in vitro and in vivo studies have shown that pulsed low dose rate (PLDR) radiotherapy has potential to provide significant local tumor control and to reduce normal tissue toxicities. This work investigated the planning and dosimetry of PLDR re-irradiation for recurrent cancers. Methods: We analyzed the treatment plans and dosimetry for 13 recurrent patients who were treated with the PLDR technique in this study. All cases were planned with the 3DCRT technique with optimal beam angle selection. The treatment was performed on a Siemens accelerator using 6MV beams. The target volume ranged between 161 and 703cc. The previous RT dose was 40–60Gy while the re-irradiation dose was 16–60Gy. The interval between previous RT and re-irradiation was 13–336 months, and the follow-up time was up to 27months. The total prescription dose was administered in 2Gy/day fractions with the daily dose delivered in 10 sub-fractions (pulses) of 20cGy with a 3min interval between the pulses to achieve an effective dose rate of 6.7cGy/min. Results: The clinical outcome was analyzed based on the treatment plans. All pulses were kept with Dmax<40cGy. The PLDR treatments were effective (CR: 3 patients, PR: 10 patients). The acute and late toxicities were all acceptable (generally grade II or under). Two patients died three months after the PLDR re-irradiation, one due to massive cerebral infarction and the other due to acute cardiac failure. All others survived more than 8 months. Five patients showed good conditions at the last follow-up. Among them two recurrent lung cancer patients had survived 23 months and one nasopharyngeal cancer patient had survived 27 months. Conclusion: The PLDR technique was effective for the palliative treatment of head and neck, lung, spine and GYN cancers. Further phase II and III studies are warranted to quantify the efficacy of PLDR for recurrent cancers.

  19. Acoustic dose and acoustic dose-rate.

    Science.gov (United States)

    Duck, Francis

    2009-10-01

    Acoustic dose is defined as the energy deposited by absorption of an acoustic wave per unit mass of the medium supporting the wave. Expressions for acoustic dose and acoustic dose-rate are given for plane-wave conditions, including temporal and frequency dependencies of energy deposition. The relationship between the acoustic dose-rate and the resulting temperature increase is explored, as is the relationship between acoustic dose-rate and radiation force. Energy transfer from the wave to the medium by means of acoustic cavitation is considered, and an approach is proposed in principle that could allow cavitation to be included within the proposed definitions of acoustic dose and acoustic dose-rate.

  20. All about Heart Rate (Pulse)

    Science.gov (United States)

    ... get a picture of your health. Learn more: Blood Pressure Vs. Heart Rate Target Heart Rate Arrhythmias (abnormal heart rhythms) This ... Healthy 6 What are the Symptoms of High Blood Pressure? 7 All About Heart Rate (Pulse) 8 Warning Signs of a Heart Attack ...

  1. Pulsed dose rate brachytherapy as the boost in combination with external beam irradiation in base of tongue cancer. Long-term results from a uniform clinical series

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2011-03-01

    Full Text Available Purpose: To evaluate long time outcome with regard to local tumour control, side effects and quality of life of combined pulsed dose rate (PDR boost and hyperfractionated accelerated external beam radiotherapy (EBRT for primary base of tongue (BOT cancers. Material and methods: Between 1994 and 2007, the number of 83 patients were treated with primary T1-T4 BOT cancers. Seven patients (8% were T1-2N0 (AJCC stage I-II and 76 (92% patients were T1-2N+ or T3-4N0-2 (AJCC stage III-IV. The mean estimated primary tumour volume was 15.4 (1-75 cm3. EBRT was given with 1.7 Gy bid to 40.8 Gy to primary tumour and bilateral neck lymph nodes in 2.5 weeks. PDR boost of 35 Gy and a neck dissection in clinical node positive case was performed 2-3 weeks later. The patients were followed for a median of 54 (2-168 months. Results: The 2-, 5- and 10-years rates of actuarial local control were 91%, 89% and 85%, overall survival 85%, 65% and 44%, disease free survival 86%, 80% and 76%, respectively. The regional control rate was 95%. Six patients (7% developed distant metastases. A dosimetric analysis showed a mean of 100% isodose volume of 58.2 (16.7-134 cm3. In a review of late complications 11 cases of minor (13% and 5 of major soft tissue necroses (6%, as well as 6 cases of osteoradionecroses (7% were found. The patients median subjective SOMA/LENT scoring at last follow up was as follow: grade 0 for pain and trismus, grade 1 for dysphagia and taste alteration, and grade 2 for xerostomia. Global visual- analogue-scale (VAS scoring of quality of life was 8. Conclusion: Local and regional tumour control rate was excellent in this treatment protocol. The data shows the PDR boost as at least as effective as published continuous low dose rate (CLDR results.

  2. Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator

    Science.gov (United States)

    Chen, Dakai; Forney, James

    2017-01-01

    The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).

  3. Economic assessment of pulsed dose-rate (P.D.R.) brachytherapy with optimized dose distribution for cervix carcinoma;Evaluation economique de la curietherapie de debit pulse gynecologique (PDR) avec optimisation de la dose pour les cancers du col uterin

    Energy Technology Data Exchange (ETDEWEB)

    Remonnay, R.; Morelle, M.; Pommier, P.; Carrere, M.O. [Lyon Univ., 69 (France); Remonnay, R.; Morelle, M.; Pommier, P. [Axe Economie de la Sante, GATE, CNRS-UMR 5824, Centre Leon-Berard, 69 - Lyon (France); Pommier, P. [Centre Leon-Berard, 69 - Lyon (France); Haie-Meder, C. [Institut Gustave-Roussy, 94 - Villejuif (France); Quetin, P. [Centre Paul-Strauss, 67 - Strasbourg (France); Kerr, C. [Centre Val-d' Aurelle, parc Euromedecine, 34 - Montpellier (France); Delannes, M. [Institut Claudius-Regaud, 31 - Toulouse (France); Castelain, B. [Centre Oscar-Lambret, 59 - Lille (France); Peignaux, K. [Centre Georges Francois Leclerc, 21 - Dijon (France); Kirova, Y. [Institut Curie, 75 - Paris (France); Romestaing, P. [Centre hospitalier Lyon Sud, 69 - Pierre-Benite (France); Williaume, D. [Centre Eugene-Marquis, 35 - Rennes (France); Krzisch, C. [Hopital Sud, 80 - Amiens (France); Thomas, L. [Institut Bergonie, 33 - Bordeaux (France); Lang, P. [Groupe hospitalier Pitie-Salpetriere, 75 - Paris (France); Baron, M.H. [Hopital Jean-Minjoz, 25 - Besancon (France); Cussac, A. [Centre Rene-Gauducheau, 44 - Nantes-Saint-Herblain (France); Lesaunier, F. [Centre Francois-Baclesse, 14 - Caen (France); Maillard, S. [Institut Jean-Godinot, 51 - Reims (France); Barillot, I. [Hopital Bretonneau, 37 - Tours (France); Charra-Brunaud, C.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France)

    2010-06-15

    Purpose: Our study aims at evaluating the cost of pulsed dose-rate (P.D.R.) brachytherapy with optimized dose distribution versus traditional treatments (iridium wires, cesium, non-optimized P.D.R.). Issues surrounding reimbursement were also explored. Materials and methods: This prospective, multi-centre, non-randomized study conducted in the framework of a project entitled 'Support Program for Costly Diagnostic and Therapeutic Innovations' involved 21 hospitals. Patients with cervix carcinoma received either classical brachytherapy or the innovation. The direct medical costs of staff and equipment, as well as the costs of radioactive sources, consumables and building renovation were evaluated from a hospital point of view using a micro costing approach. Subsequent costs per brachytherapy were compared between the four strategies. Results: The economic study included 463 patients over two years. The main resources categories associated with P.D.R. brachytherapy (whether optimized or not) were radioactive sources (1053 Euros) and source projectors (735 Euros). Optimized P.D.R. induced higher cost of imagery and dosimetry (respectively 130 Euros and 367 Euros) than non-optimized P.D.R. (47 Euros and 75 Euros). Extra costs of innovation over the less costly strategy (iridium wires) reached more than 2100 Euros per treatment, but could be reduced by half in the hypothesis of 40 patients treated per year (instead of 24 in the study). Conclusion: Aside from staff, imaging and dosimetry, the current hospital reimbursements largely underestimated the cost of innovation related to equipment and sources. (authors)

  4. Atmospheric radiation flight dose rates

    Science.gov (United States)

    Tobiska, W. K.

    2015-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has been conducting space weather observations of the atmospheric radiation environment at aviation altitudes that will eventually be transitioned into air traffic management operations. The Automated Radiation Measurements for Aerospace Safety (ARMAS) system and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) both are providing dose rate measurements. Both activities are under the ARMAS goal of providing the "weather" of the radiation environment to improve aircraft crew and passenger safety. Over 5-dozen ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. Flight altitudes now exceed 60,000 ft. and extend above commercial aviation altitudes into the stratosphere. In this presentation we describe recent ARMAS and USEWX results.

  5. Dose rate mapping of VMAT treatments

    Science.gov (United States)

    Podesta, Mark; Antoniu Popescu, I.; Verhaegen, Frank

    2016-06-01

    Human tissues exhibit a varying response to radiation dose depending on the dose rate and fractionation scheme used. Dose rate effects have been reported for different radiations, and tissue types. The literature indicates that there is not a significant difference in response for low-LET radiation when using dose rates between 1 Gy min-1 and 12 Gy min-1 but lower dose rates have an observable sparing effect on tissues and a differential effect between tissues. In intensity-modulated radiotherapy such as volumetric modulated arc therapy (VMAT) the dose can be delivered with a wide range of dose rates. In this work we developed a method based on time-resolved Monte Carlo simulations to quantify the dose rate frequency distribution for clinical VMAT treatments for three cancer sites, head and neck, lung, and pelvis within both planning target volumes (PTV) and normal tissues. The results show a wide range of dose rates are used to deliver dose in VMAT and up to 75% of the PTV can have its dose delivered with dose rates  organs at risk. Two VMAT plans that fulfil the same dose objectives and constraints may be delivered with different dose rate distributions, particularly when comparing single arcs to multiple arc plans. It is concluded that for dynamic plans, the dose rate range used varies to a larger degree than previously assumed. The effect of the dose rate range in VMAT on clinical outcome is unknown.

  6. Estimation of the Dose and Dose Rate Effectiveness Factor

    Science.gov (United States)

    Chappell, L.; Cucinotta, F. A.

    2013-01-01

    Current models to estimate radiation risk use the Life Span Study (LSS) cohort that received high doses and high dose rates of radiation. Transferring risks from these high dose rates to the low doses and dose rates received by astronauts in space is a source of uncertainty in our risk calculations. The solid cancer models recommended by BEIR VII [1], UNSCEAR [2], and Preston et al [3] is fitted adequately by a linear dose response model, which implies that low doses and dose rates would be estimated the same as high doses and dose rates. However animal and cell experiments imply there should be curvature in the dose response curve for tumor induction. Furthermore animal experiments that directly compare acute to chronic exposures show lower increases in tumor induction than acute exposures. A dose and dose rate effectiveness factor (DDREF) has been estimated and applied to transfer risks from the high doses and dose rates of the LSS cohort to low doses and dose rates such as from missions in space. The BEIR VII committee [1] combined DDREF estimates using the LSS cohort and animal experiments using Bayesian methods for their recommendation for a DDREF value of 1.5 with uncertainty. We reexamined the animal data considered by BEIR VII and included more animal data and human chromosome aberration data to improve the estimate for DDREF. Several experiments chosen by BEIR VII were deemed inappropriate for application to human risk models of solid cancer risk. Animal tumor experiments performed by Ullrich et al [4], Alpen et al [5], and Grahn et al [6] were analyzed to estimate the DDREF. Human chromosome aberration experiments performed on a sample of astronauts within NASA were also available to estimate the DDREF. The LSS cohort results reported by BEIR VII were combined with the new radiobiology results using Bayesian methods.

  7. Dose rate mapping of VMAT treatments.

    Science.gov (United States)

    Podesta, Mark; Popescu, I Antoniu; Verhaegen, Frank

    2016-06-01

    Human tissues exhibit a varying response to radiation dose depending on the dose rate and fractionation scheme used. Dose rate effects have been reported for different radiations, and tissue types. The literature indicates that there is not a significant difference in response for low-LET radiation when using dose rates between 1 Gy min(-1) and 12 Gy min(-1) but lower dose rates have an observable sparing effect on tissues and a differential effect between tissues. In intensity-modulated radiotherapy such as volumetric modulated arc therapy (VMAT) the dose can be delivered with a wide range of dose rates. In this work we developed a method based on time-resolved Monte Carlo simulations to quantify the dose rate frequency distribution for clinical VMAT treatments for three cancer sites, head and neck, lung, and pelvis within both planning target volumes (PTV) and normal tissues. The results show a wide range of dose rates are used to deliver dose in VMAT and up to 75% of the PTV can have its dose delivered with dose rates  <1 Gy min(-1). Pelvic plans on average have a lower mean dose rate within the PTV than lung or head and neck plans but a comparable mean dose rate within the organs at risk. Two VMAT plans that fulfil the same dose objectives and constraints may be delivered with different dose rate distributions, particularly when comparing single arcs to multiple arc plans. It is concluded that for dynamic plans, the dose rate range used varies to a larger degree than previously assumed. The effect of the dose rate range in VMAT on clinical outcome is unknown.

  8. The Radiation Dose Determination of the Pulsed X-ray Source

    Science.gov (United States)

    Miloichikova, I.; Stuchebrov, S.; Zhaksybayeva, G.; Wagner, A.

    2014-10-01

    In this paper the radiation dose measurement technique of the pulsed X-ray source RAP-160-5 is described. The dose rate measurement results from the pulsed X-ray beams at the different distance between the pulsed X-ray source focus and the detector obtained with the help of the thermoluminescent detectors DTL-02, the universal dosimeter UNIDOS E equipped with the plane-parallel ionization chamber type 23342, the dosimeter-radiometer DKS-96 and the radiation dosimeter AT 1123 are demonstrated. The recommendations for the dosimetry measurements of the pulsed X-ray generator RAP-160-5 under different radiation conditions are proposed.

  9. Assessing dose rate distributions in VMAT plans

    Science.gov (United States)

    Mackeprang, P.-H.; Volken, W.; Terribilini, D.; Frauchiger, D.; Zaugg, K.; Aebersold, D. M.; Fix, M. K.; Manser, P.

    2016-04-01

    Dose rate is an essential factor in radiobiology. As modern radiotherapy delivery techniques such as volumetric modulated arc therapy (VMAT) introduce dynamic modulation of the dose rate, it is important to assess the changes in dose rate. Both the rate of monitor units per minute (MU rate) and collimation are varied over the course of a fraction, leading to different dose rates in every voxel of the calculation volume at any point in time during dose delivery. Given the radiotherapy plan and machine specific limitations, a VMAT treatment plan can be split into arc sectors between Digital Imaging and Communications in Medicine control points (CPs) of constant and known MU rate. By calculating dose distributions in each of these arc sectors independently and multiplying them with the MU rate, the dose rate in every single voxel at every time point during the fraction can be calculated. Independently calculated and then summed dose distributions per arc sector were compared to the whole arc dose calculation for validation. Dose measurements and video analysis were performed to validate the calculated datasets. A clinical head and neck, cranial and liver case were analyzed using the tool developed. Measurement validation of synthetic test cases showed linac agreement to precalculated arc sector times within  ±0.4 s and doses  ±0.1 MU (one standard deviation). Two methods for the visualization of dose rate datasets were developed: the first method plots a two-dimensional (2D) histogram of the number of voxels receiving a given dose rate over the course of the arc treatment delivery. In similarity to treatment planning system display of dose, the second method displays the dose rate as color wash on top of the corresponding computed tomography image, allowing the user to scroll through the variation over time. Examining clinical cases showed dose rates spread over a continuous spectrum, with mean dose rates hardly exceeding 100 cGy min-1 for conventional

  10. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    Energy Technology Data Exchange (ETDEWEB)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  11. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects w

  12. Absorbed Dose Distribution in a Pulse Radiolysis Optical Cell

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    When a liquid solution in an optical cell is irradiated by an intense pulsed electron beam, it may be important in the chemical analysis of the solution to know the distribution of energy deposited throughout the cell. For the present work, absorbed dose distributions were measured by thin...

  13. Radiation Leukemogenesis at Low Dose Rates

    Energy Technology Data Exchange (ETDEWEB)

    Weil, Michael; Ullrich, Robert

    2013-09-25

    The major goals of this program were to study the efficacy of low dose rate radiation exposures for the induction of acute myeloid leukemia (AML) and to characterize the leukemias that are caused by radiation exposures at low dose rate. An irradiator facility was designed and constructed that allows large numbers of mice to be irradiated at low dose rates for protracted periods (up to their life span). To the best of our knowledge this facility is unique in the US and it was subsequently used to study radioprotectors being developed for radiological defense (PLoS One. 7(3), e33044, 2012) and is currently being used to study the role of genetic background in susceptibility to radiation-induced lung cancer. One result of the irradiation was expected; low dose rate exposures are ineffective in inducing AML. However, another result was completely unexpected; the irradiated mice had a very high incidence of hepatocellular carcinoma (HCC), approximately 50%. It was unexpected because acute exposures are ineffective in increasing HCC incidence above background. This is a potential important finding for setting exposure limits because it supports the concept of an 'inverse dose rate effect' for some tumor types. That is, for the development of some tumor types low dose rate exposures carry greater risks than acute exposures.

  14. Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations

    CERN Document Server

    Yamauchi, T; Oda, K; Ikeda, T; Honda, Y; Tagawa, S

    1999-01-01

    The effect of gamma-rays and pulsed electrons has been investigated on the bulk etch rate of CR-39 detector at doses up to 100 kGy under various dose-rate between 0.0044 and 35.0 Gy/s. The bulk etch rate increased exponentially with the dose at every examined dose-rates. It was reveled to be strongly depend on the dose-rate: the bulk etch rate was decreased with increasing dose-rate at the same total dose. A primitive model was proposed to explain the dose-rate effect in which oxygen dissolved was assumed to dominate the damage formation process.

  15. Breakdown behavior of electronics at variable pulse repetition rates

    OpenAIRE

    Korte, S.; H. Garbe

    2006-01-01

    The breakdown behavior of electronics exposed to single transient electromagnetic pulses is subject of investigations for several years. State-of-the-art pulse generators additionally provide the possibility to generate pulse sequences with variable pulse repetition rate. In this article the influence of this repetition rate variation on the breakdown behavior of electronic systems is described. For this purpose microcontroller systems are examined during line-led exposure to pulses with repe...

  16. [Hopes of high dose-rate radiotherapy].

    Science.gov (United States)

    Fouillade, Charles; Favaudon, Vincent; Vozenin, Marie-Catherine; Romeo, Paul-Henri; Bourhis, Jean; Verrelle, Pierre; Devauchelle, Patrick; Patriarca, Annalisa; Heinrich, Sophie; Mazal, Alejandro; Dutreix, Marie

    2017-04-01

    In this review, we present the synthesis of the newly acquired knowledge concerning high dose-rate irradiations and the hopes that these new radiotherapy modalities give rise to. The results were presented at a recent symposium on the subject. Copyright © 2017. Published by Elsevier Masson SAS.

  17. Properties of water surface discharge at different pulse repetition rates

    Energy Technology Data Exchange (ETDEWEB)

    Ruma,; Yoshihara, K. [Graduate School of Science and Technology, Kumamoto University, Kumamoto 860-8555 (Japan); Hosseini, S. H. R., E-mail: hosseini@kumamoto-u.ac.jp; Sakugawa, T.; Akiyama, H. [Graduate School of Science and Technology, Kumamoto University, Kumamoto 860-8555 (Japan); Institute of Pulsed Power Science, Kumamoto University, Kumamoto 860-8555 (Japan); Akiyama, M. [Department of Electrical and Electronic Engineering, Kagoshima University, Kagoshima 890-0065 (Japan); Lukeš, P. [Institute of Plasma Physics, AS CR, Prague, Prague 18200 (Czech Republic)

    2014-09-28

    The properties of water surface discharge plasma for variety of pulse repetition rates are investigated. A magnetic pulse compression (MPC) pulsed power modulator able to deliver pulse repetition rates up to 1000 Hz, with 0.5 J per pulse energy output at 25 kV, was used as the pulsed power source. Positive pulse with a point-to-plane electrode configuration was used for the experiments. The concentration and production yield of hydrogen peroxide (H₂O₂) were quantitatively measured and orange II organic dye was treated, to evaluate the chemical properties of the discharge reactor. Experimental results show that the physical and chemical properties of water surface discharge are not influenced by pulse repetition rate, very different from those observed for under water discharge. The production yield of H₂O₂ and degradation rate per pulse of the dye did not significantly vary at different pulse repetition rates under a constant discharge mode on water surface. In addition, the solution temperature, pH, and conductivity for both water surface and underwater discharge reactors were measured to compare their plasma properties for different pulse repetition rates. The results confirm that surface discharge can be employed at high pulse repetition rates as a reliable and advantageous method for industrial and environmental decontamination applications.

  18. Dose rate and SDD dependence of commercially available diode detectors.

    Science.gov (United States)

    Saini, Amarjit S; Zhu, Timothy C

    2004-04-01

    The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10 x 10 cm2 collimator setting, by varying source-to-detector distance (SDD) between at least 80 and 200 cm. The ratio of a normalized diode reading to a normalized ion chamber reading (both at SDD=100 cm) was used to determine diode sensitivity ratio for pulsed and continuous radiation at different SDD. The inverse of the diode sensitivity ratio is defined as the SDD correction factor (SDD CF). The diode sensitivity ratio increased with increasing instantaneous dose rate (or decreasing SDD). The ratio of diode sensitivity, normalized to 4000 cGy/s, varied between 0.988 (1490 cGy/s)-1.023 (38,900 cGy/s) for unirradiated n-type Isorad Gold, 0.981 (1460 cGy/s)-1.026 (39,060 cGy/s) for unirradiated QED Red (n type), 0.972 (1490 cGy/s)-1.068 (38,900 cGy/s) for preirradiated Isorad Red (n type), 0.985 (1490 cGy/s)-1.012 (38,990 cGy/s) for n-type Pt-doped Isorad-3 Gold, 0.995 (1450 cGy/s)-1.020 (21,870 cGy/s) for n-type Veridose Green, 0.978 (1450 cGy/s)-1.066 (21,870 cGy/s) for preirradiated Isorad-p Red, 0.994 (1540 cGy/s)-1.028 (17,870 cGy/s) for p-type preirradiated QED, 0.998 (1450 cGy/s)-1.003 (21,870 cGy/s) for the p-type preirradiated Scanditronix EDP20(3G), and 0.998 (1490 cGy/s)-1.015 (38,880 cGy/s) for Scanditronix EDP10(3G) diodes. The p-type diodes do not always show less dose-rate dependence than the n-type diodes. Preirradiation does not always reduce diode dose-rate dependence. A comparison between the SDD dependence measured at the surface of a full scatter phantom and that in a miniphantom was made. Using a direct adjustment of radiation pulse height, we concluded that the SDD dependence of diode sensitivity can be explained by the instantaneous dose-rate dependence if sufficient buildup is

  19. Characterization of the exradin A18 chamber ionization according to the IEC70631 standards. This work aims at the characterization of the Exradin model (Standard Imaging) A18 ionization chamber, according to the international standard IEC 607311. Intends to use the camera Exradin A18 for the quality control of a linear accelerator VARIAN model TrueBeam with capacity to produce beams of photons of high energy, unfiltered flatter (in later FFF) with high dose absorbed by pulse rate, why is verified, according to the mentioned standard IEC 60731, even under conditions of high dose absorbed by pulse rate, the efficiency of ion collection from this camera is within tolerances; Caracterizacion de la camara de ionizacion exradin A18 segun el estandar IEC70631. Estudio para haces de fotones sin filtro aplanador

    Energy Technology Data Exchange (ETDEWEB)

    Onses Segarra, A.; Puxeu Vaque, J.; Sancho Kolster, I.; Lizuain Arroyo, M. C.; Picon Olmos, C.

    2013-07-01

    This work aims at the characterization of the Exradin model (Standard Imaging) A18 ionization chamber, according to the international standard IEC 607311. Intends to use the camera Exradin A18 for the quality control of a linear accelerator VARIAN model TrueBeam with capacity to produce beams of photons of high energy, unfiltered flatter (in later FFF) with high dose absorbed by pulse rate, why is verified, according to the mentioned standard IEC 60731, even under conditions of high dose absorbed by pulse rate, the efficiency of ion collection from this camera is within tolerances. (Author)

  20. Pulse

    Science.gov (United States)

    ... resting for at least 10 minutes. Take the exercise heart rate while you are exercising. ... pulse rate can help determine if the person's heart is pumping. Pulse ... rate gives information about your fitness level and health.

  1. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Hideya [Toyonaka Municipal Hospital, Osaka (Japan); Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko [Osaka Univ., Suita (Japan). Graduate School of Medicine; Furukawa, Souhei; Kakimoto, Naoya [Osaka Univ., Suita (Japan). Graduate School of Dentistry

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  2. Brachytherapy for early oral tongue cancer: low dose rate to high dose rate.

    Science.gov (United States)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Furukawa, Souhei; Kakimoto, Naoya; Shimizutani, Kimishige; Inoue, Toshihiko

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n = 341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer.

  3. Design and Study of Data Acquisition System for Pulsed γ Dose Measurement Device

    Institute of Scientific and Technical Information of China (English)

    DOU; Yu-ling; YANG; Shao-hua; ZHANG; Guo-guang

    2012-01-01

    <正>A data acquisition system for online pulsed gamma dose measurement device was designed and developed (Fig. 1), and its performance was tested. The results show that the data acquisition system in both the continued and pulsed input, output electric charges and input energy have a good linear relationship. Experiments were done respectively on the XRS-3 pulsed source and re-frequency

  4. Survival of tumor cells after proton irradiation with ultra-high dose rates

    Directory of Open Access Journals (Sweden)

    Belka Claus

    2011-10-01

    Full Text Available Abstract Background Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >109 Gy s-1may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. Methods The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within Results At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD, respectively. Conclusions At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional continuous irradiation mode do not differ significantly.

  5. Pulsed high-dose dexamethasone versus standard prednisolone treatment for chronic inflammatory demyelinating polyradiculoneuropathy (PREDICT study): a double-blind, randomised, controlled trial.

    NARCIS (Netherlands)

    Schaik, I.N. van; Eftimov, F.; Doorn, P.A. van; Brusse, E.; Berg, L.H. van den; Pol, W.L. van der; Faber, C.G.; Oostrom, J.C. van; Vogels, O.J.M.; Hadden, R.D.; Kleine, B.U.; Norden, A.G.W. van; Verschuuren, J.J.; Dijkgraaf, M.G.; Vermeulen, M.

    2010-01-01

    BACKGROUND: Pulsed high-dose dexamethasone induced long-lasting remission in patients with chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) in a pilot study. The PREDICT study aimed to compare remission rates in patients with CIDP treated with high-dose dexamethasone with rates in pa

  6. Pulsed high-dose dexamethasone versus standard prednisolone treatment for chronic inflammatory demyelinating polyradiculoneuropathy (PREDICT study) : a double-blind, randomised, controlled trial

    NARCIS (Netherlands)

    van Schaik, Ivo N.; Eftimov, Filip; van Doorn, Pieter A.; Brusse, Esther; van den Berg, Leonard H.; van der Pol, W. Ludo; Faber, Catharina G.; van Oostrom, Joost C. H.; Vogels, Oscar J. M.; Hadden, Rob D. M.; Kleine, Bert U.; van Norden, Anouk G. W.; Verschuuren, Jan J. G. M.; Dijkgraaf, Marcel G. W.; Vermeulen, Marinus

    2010-01-01

    Background Pulsed high-dose dexamethasone induced long-lasting remission in patients with chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) in a pilot study. The PREDICT study aimed to compare remission rates in patients with CIDP treated with high-dose dexamethasone with rates in pat

  7. Pulsed high-dose dexamethasone versus standard prednisolone treatment for chronic inflammatory demyelinating polyradiculoneuropathy (PREDICT study): a double-blind, randomised, controlled trial

    NARCIS (Netherlands)

    I.N. van Schaik; F. Eftimov; P.A. van Doorn; E. Brusse; L.H. van den Berg; W.L. van der Pol; C.G. Faber; J.C. van Oostrom; O.J. Vogels; R.D. Hadden; B.U. Kleine; A.G. van Norden; J.J. Verschuuren; M.G. Dijkgraaf; M. Vermeulen

    2010-01-01

    Background Pulsed high-dose dexamethasone induced long-lasting remission in patients with chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) in a pilot study. The PREDICT study aimed to compare remission rates in patients with CIDP treated with high-dose dexamethasone with rates in pat

  8. Absorbed dose and dose rate using the Varian OBI 1.3 and 1.4 CBCT system.

    Science.gov (United States)

    Palm, Asa; Nilsson, Elisabeth; Herrnsdorf, Lars

    2010-01-28

    According to published data, the absorbed dose used for a CBCT image acquisition with Varian OBI v1.3 can be as high as 100 mGy. In 2008 Varian released a new OBI version (v1.4), which promised to reduce the imaging dose. In this study, absorbed doses used for CBCT image acquisitions with the default irradiation techniques of Varian OBI v1.3 and v1.4 are measured. TLDs are used to derive dose distributions at three planes inside an anthropomorphic phantom. In addition, point doses and dose profiles inside a 'stack' of three CTDI body phantoms are measured using a new solid state detector, the CT Dose Profiler. With the CT Dose Profiler, the individual pulses from the X-ray tube are also studied. To verify the absorbed dose measured with the CT Dose Profiler, it is compared to TLD. The image quality is evaluated using a Catphan phantom. For OBI v1.3, doses measured in transverse planes of the Alderson phantom range between 64 mGy and 144 mGy. The average dose is around 100 mGy. For OBI v1.4, doses measured in transverse planes of the Alderson phantom range between 1 mGy and 51 mGy. Mean doses range between 3-35 mGy depending on CBCT mode. CT Dose Profiler data agree with TLD measurements in a CTDI phantom within the uncertainty of the TLD measurements (estimated SD +/- 10%). Instantaneous dose rate at the periphery of the phantom can be higher than 20 mGy/s, which is 10 times the dose rate at the center. The spatial resolution in v1.4 is not as high as in v1.3. In conclusion, measurements show that the imaging doses for default modes in Varian OBI v1.4 CBCT system are significantly lower than in v1.3. The CT Dose Profiler is proven fast and accurate for CBCT applications.

  9. Dose-Dependent Mutation Rates Determine Optimum Erlotinib Dosing Strategies for EGFR Mutant Non-Small Cell Lung Cancer Patients.

    Directory of Open Access Journals (Sweden)

    Lin L Liu

    Full Text Available The advent of targeted therapy for cancer treatment has brought about a paradigm shift in the clinical management of human malignancies. Agents such as erlotinib used for EGFR-mutant non-small cell lung cancer or imatinib for chronic myeloid leukemia, for instance, lead to rapid tumor responses. Unfortunately, however, resistance often emerges and renders these agents ineffective after a variable amount of time. The FDA-approved dosing schedules for these drugs were not designed to optimally prevent the emergence of resistance. To this end, we have previously utilized evolutionary mathematical modeling of treatment responses to elucidate the dosing schedules best able to prevent or delay the onset of resistance. Here we expand on our approaches by taking into account dose-dependent mutation rates at which resistant cells emerge. The relationship between the serum drug concentration and the rate at which resistance mutations arise can lead to non-intuitive results about the best dose administration strategies to prevent or delay the emergence of resistance.We used mathematical modeling, available clinical trial data, and different considerations of the relationship between mutation rate and drug concentration to predict the effectiveness of different dosing strategies.We designed several distinct measures to interrogate the effects of different treatment dosing strategies and found that a low-dose continuous strategy coupled with high-dose pulses leads to the maximal delay until clinically observable resistance. Furthermore, the response to treatment is robust against different assumptions of the mutation rate as a function of drug concentration.For new and existing targeted drugs, our methodology can be employed to compare the effectiveness of different dose administration schedules and investigate the influence of changing mutation rates on outcomes.

  10. Radiation dose rates from UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Friend, P.J. [Urenco, Capenhurst (United Kingdom)

    1991-12-31

    This paper describes the results of many studies, both theoretical and experimental, which have been carried out by Urenco over the last 15 years into radiation dose rates from uranium hexafluoride (UF{sub 6}) cylinders. The contents of the cylinder, its history, and the geometry all affect the radiation dose rate. These factors are all examined in detail. Actual and predicted dose rates are compared with levels permitted by IAEA transport regulations.

  11. Electron dose rate and photon contamination in electron arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pla, M.; Podgorsak, E.B.; Pla, C. (McGill Univ., Montreal, Quebec (Canada))

    1989-09-01

    The electron dose rate at the depth of dose maximum dmax and the photon contamination are discussed as a function of several parameters of the rotational electron beam. A pseudoarc technique with an angular increment of 10 degrees and a constant number of monitor units per each stationary electron field was used in our experiments. The electron dose rate is defined as the electron dose at a given point in phantom divided by the number of monitor units given for any one stationary electron beam. For a given depth of isocenter di the electron dose rates at dmax are linearly dependent on the nominal field width w, while for a given w the dose rates are inversely proportional to di. The dose rates for rotational electron beams with different di are related through the inverse square law provided that the two beams have (di,w) combinations which give the same characteristic angle beta. The photon dose at the isocenter depends on the arc angle alpha, field width w, and isocenter depth di. For constant w and di the photon dose at isocenter is proportional to alpha, for constant alpha and w it is proportional to di, and for constant alpha and di it is inversely proportional to w. The w and di dependence implies that for the same alpha the photon dose at the isocenter is inversely proportional to the electron dose rate at dmax.

  12. A Pulse Rate Estimation Algorithm Using PPG and Smartphone Camera.

    Science.gov (United States)

    Siddiqui, Sarah Ali; Zhang, Yuan; Feng, Zhiquan; Kos, Anton

    2016-05-01

    The ubiquitous use and advancement in built-in smartphone sensors and the development in big data processing have been beneficial in several fields including healthcare. Among the basic vitals monitoring, pulse rate monitoring is the most important healthcare necessity. A multimedia video stream data acquired by built-in smartphone camera can be used to estimate it. In this paper, an algorithm that uses only smartphone camera as a sensor to estimate pulse rate using PhotoPlethysmograph (PPG) signals is proposed. The results obtained by the proposed algorithm are compared with the actual pulse rate and the maximum error found is 3 beats per minute. The standard deviation in percentage error and percentage accuracy is found to be 0.68 % whereas the average percentage error and percentage accuracy is found to be 1.98 % and 98.02 % respectively.

  13. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  14. [Experimental investigation of the collection efficiency of a PTW Roos ionization chamber irradiated with pulsed beams at high pulse dose with different pulse lengths].

    Science.gov (United States)

    Karsch, Leonhard; Richter, Christian; Pawelke, Jörg

    2011-01-01

    In gas-filled ionization chambers as radiation detectors, the collection of the charge carriers is affected by the recombination effect. In dosimetry this effect must be accounted for by the saturation correction factor k(S). The physical description of the correction factor by Boag, Hochhäuser and Balk for pulsed radiation is well established. However, this description is only accurate when the pulse length is short compared to the collection time of the ionization chamber. In this work experimental investigations of the saturation correction factor have been made for pulses of 4 μ s up to pulse doses of about 230 mGy, and the theory of Boag, Hochhäuser and Balk was again confirmed. For longer pulses, however, the correction factor decreases and at a pulse duration of about 200μs reaches 75% of the value valid for short pulses. This reduced influence of the ion recombination is interpreted by the reaction kinetics of ion recombination as a second-order reaction. This effect is negligible for PTW Roos chambers at clinical linear accelerators with 4 μ s pulse duration for pulse doses up to 120 mGy.

  15. Dose and dose rate effects of irradiation on blood count and cytokine assay in mice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joong Sun [Research center, Dongnam institute of radiological and Medical Sciences (DIRAMS), Busan (Korea, Republic of)

    2013-11-15

    The possible role of exposure to radiation as a risk factor for human health has been of increasing public concern in the series of explosions at earthquake damaged nuclear reactors on the Japan. Current events throughout the world underscore the growing threat of different forms of accidental exposure to radiation including nuclear accidents, atomic weapons use and testing, and the side effects of cancer therapy. A large range of dose rates of ionizing radiations could be encountered in accidental radiation situations. Nevertheless, most of the studies related to radiation effects have only examined a high dose rate. In this study, we investigated the blood count and the cytokine levels in the serum of mice exposed to a high or low dose rate of radiation. In this study, the precise molecular mechanism underlying the low dose rate of radiation remains unclear, but differential hematopoietic effects of radiation exposed at a high dose rate versus low dose rate were observed using the number of peripheral blood count and serum cytokines. These data suggest that chronic low dose rate exposure caused a stimulation of heamatopoietic system occurrence, unlike those observed after higher dose rate exposure. Our data suggest that the dose rate, rather than the total dose, may be more critical in causing damage to the cellular hematopoietic compartments of the body.

  16. Total ionizing dose effects of domestic SiGe HBTs under different dose rates

    Science.gov (United States)

    Liu, Mo-Han; Lu, Wu; Ma, Wu-Ying; Wang, Xin; Guo, Qi; He, Cheng-Fa; Jiang, Ke; Li, Xiao-Long; Xun, Ming-Zhu

    2016-03-01

    The total ionizing radiation (TID) response of commercial NPN silicon germanium hetero-junction bipolar transistors (SiGe HBTs) produced domestically are investigated under dose rates of 800 mGy(Si)/s and 1.3 mGy(Si)/s with a Co-60 gamma irradiation source. The changes of transistor parameters such as Gummel characteristics, and excess base current before and after irradiation, are examined. The results of the experiments show that for the KT1151, the radiation damage is slightly different under the different dose rates after prolonged annealing, and shows a time dependent effect (TDE). For the KT9041, however, the degradations of low dose rate irradiation is higher than for the high dose rate, demonstrating that there is a potential enhanced low dose rate sensitivity (ELDRS) effect for the KT9041. The possible underlying physical mechanisms of the different dose rates responses induced by the gamma rays are discussed.

  17. Total ionizing dose effects of domestic SiGe HBTs under different dose rate

    CERN Document Server

    Mo-Han, Liu; Wu-Ying, Ma; Xin, Wang; Qi, Guo; Cheng-Fa, He; Ke, Jiang; Xiao-Long, Li; Ming-Zhu, Xiong

    2015-01-01

    The total ionizing radiation (TID) response of commercial NPN silicon germanium hetero-junction bipolar transistors (SiGe HBTs) produced domestic were investigated under the dose rate of 800mGy(Si)/s and 1.3mGy(Si)/s with Co-60 gamma irradiation source, respectively. The changes of the transistor parameter such as Gummel characteristics, excess base current before and after irradiation are investigated. The results of the experiments shows that for the KT1151, the radiation damage have slightly difference under the different dose rate after the prolonged annealing, shows an time dependent effect(TDE). But for the KT9041, the degradations of low dose rate irradiation are more higher than the high dose rate, demonstrate that there have potential enhanced low dose rate sensitive(ELDRS) effect exist on KT9041. The underlying physical mechanisms of the different dose rates response induced by the gamma ray are detailed discussed.

  18. Complex pulsing schemes for high frame rate imaging

    DEFF Research Database (Denmark)

    Misaridis, Thanassis; Fink, Mathias; Jensen, Jørgen Arendt

    2002-01-01

    High frame rate ultrasound imaging can be achieved by simultaneous transmission of multiple focused beams along different directions. However, image quality degrades by the interference among beams. An alternative approach is to transmit spherical waves of a basic short pulse with frequency coding...... with linear frequency modulation along the transducer elements, that cover the 70% fractional bandwidth of the 7 MHz transducer. The resulted images (after beamforming and matched filtering) show an axial resolution at the same order as in conventional pulse excitation and axial sidelobes down to -45 d......B. With the proposed imaging strategy of pulse train excitation, a whole image can be formed with only two emissions, making it possible to obtain high quality images at a frame rate of 20 to 25 times higher than that of conventional phased array imaging...

  19. Patient Blood Pressure and Pulse Rate Monitoring With an Alert ...

    African Journals Online (AJOL)

    2012-12-01

    Dec 1, 2012 ... Blood pressure and pulse rate are two of the vital signs of humans and it is ... even from their homes and transfer the readings into the computer ... benefits from Omron's 'IntelliSense' .... (the port number assigned to the smart.

  20. Topographic Effects on Ambient Dose Equivalent Rates from Radiocesium Fallout

    CERN Document Server

    Malins, Alex; Machida, Masahiko; Saito, Kimiaki

    2015-01-01

    Land topography can affect air radiation dose rates by locating radiation sources closer to, or further, from detector locations when compared to perfectly flat terrain. Hills and slopes can also shield against the propagation of gamma rays. To understand the possible magnitude of topographic effects on air dose rates, this study presents calculations for ambient dose equivalent rates at a range of heights above the ground for varying land topographies. The geometries considered were angled ground at the intersection of two planar surfaces, which is a model for slopes neighboring flat land, and a simple conical geometry, representing settings from hilltops to valley bottoms. In each case the radiation source was radioactive cesium fallout, and the slope angle was varied systematically to determine the effect of topography on the air dose rate. Under the assumption of homogeneous fallout across the land surface, and for these geometries and detector locations, the dose rates at high altitudes are more strongly...

  1. Onset of leptin resistance shows temporal differences related to dose or pulsed treatment.

    Science.gov (United States)

    Strehler, Kevin Y E; Matheny, Michael; Kirichenko, Nataliya; Sakarya, Yasemin; Bruce, Erin; Toklu, Hale Zerrin; Carter, Christy S; Morgan, Drake; Tümer, Nihal; Scarpace, Philip J

    2016-05-15

    Leptin administration results in leptin resistance presenting a significant barrier to therapeutic use of leptin. Consequently, we examined two hypotheses. The first examined the relationship between leptin dose and development of physiological and biochemical signs of leptin resistance. We hypothesized lower doses of leptin would produce proportional reductions in body weight without the adverse leptin-induced leptin resistance. The second compared pulsed central leptin infusion to continuous leptin infusion. We hypothesized that pulsed infusion at specific times of the day would evoke favorable body weight reductions while tempering the development of leptin-induced leptin resistance. The first experiment examined leptin responsiveness, including food intake, body weight and hypothalamic STAT3 phosphorylation to increasing doses of viral gene delivery of leptin. Varying the dose proved inconsequential with respect to long-term therapy and demonstrated proportional development of leptin resistance. The second experiment examined leptin responsiveness to pulsed central leptin infusion, comparing pulsed versus constant infusion of 3μg/day leptin or a 2h morning versus a 2h evening pulsed leptin infusion. Pulsed delivery of the supramaximal dose of 3μg/day was not different than constant delivery. Morning pulsed infusion of the submaximal dose of 0.25μg reduces food intake only over subsequent immediate meal period and was associated with body weight reductions, but results in cellular leptin resistance. Evening pulsed infusion did not decrease food intake but reduces body weight and maintains full leptin signaling. The positive benefit for pulsed delivery remains speculative, yet potentially may provide an alternative mode of leptin therapy.

  2. High voltage high repetition rate pulse using Marx topology

    Science.gov (United States)

    Hakki, A.; Kashapov, N.

    2015-06-01

    The paper describes Marx topology using MOSFET transistors. Marx circuit with 10 stages has been done, to obtain pulses about 5.5KV amplitude, and the width of the pulses was about 30μsec with a high repetition rate (PPS > 100), Vdc = 535VDC is the input voltage for supplying the Marx circuit. Two Ferrite ring core transformers were used to control the MOSFET transistors of the Marx circuit (the first transformer to control the charging MOSFET transistors, the second transformer to control the discharging MOSFET transistors).

  3. External dose-rate conversion factors for calculation of dose to the public

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents a tabulation of dose-rate conversion factors for external exposure to photons and electrons emitted by radionuclides in the environment. This report was prepared in conjunction with criteria for limiting dose equivalents to members of the public from operations of the US Department of Energy (DOE). The dose-rate conversion factors are provided for use by the DOE and its contractors in performing calculations of external dose equivalents to members of the public. The dose-rate conversion factors for external exposure to photons and electrons presented in this report are based on a methodology developed at Oak Ridge National Laboratory. However, some adjustments of the previously documented methodology have been made in obtaining the dose-rate conversion factors in this report. 42 refs., 1 fig., 4 tabs.

  4. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  5. Acousto-optic pulse picking scheme with carrier-frequency-to-pulse-repetition-rate synchronization.

    Science.gov (United States)

    de Vries, Oliver; Saule, Tobias; Plötner, Marco; Lücking, Fabian; Eidam, Tino; Hoffmann, Armin; Klenke, Arno; Hädrich, Steffen; Limpert, Jens; Holzberger, Simon; Schreiber, Thomas; Eberhardt, Ramona; Pupeza, Ioachim; Tünnermann, Andreas

    2015-07-27

    We introduce and experimentally validate a pulse picking technique based on a travelling-wave-type acousto-optic modulator (AOM) having the AOM carrier frequency synchronized to the repetition rate of the original pulse train. As a consequence, the phase noise characteristic of the original pulse train is largely preserved, rendering this technique suitable for applications requiring carrier-envelope phase stabilization. In a proof-of-principle experiment, the 1030-nm spectral part of an 74-MHz, carrier-envelope phase stable Ti:sapphire oscillator is amplified and reduced in pulse repetition frequency by a factor of two, maintaining an unprecedentedly low carrier-envelope phase noise spectral density of below 68 mrad. Furthermore, a comparative analysis reveals that the pulse-picking-induced additional amplitude noise is minimized, when the AOM is operated under synchronicity. The proposed scheme is particularly suitable when the down-picked repetition rate is still in the multi-MHz-range, where Pockels cells cannot be applied due to piezoelectric ringing.

  6. Dosimetric measurements and Monte Carlo simulation for achieving uniform surface dose in pulsed electron beam irradiation facility

    Indian Academy of Sciences (India)

    V C Petwal; J N Rao; Jishnu Dwivedi; V K Senecha; K V Subbaiah

    2010-03-01

    A prototype pulsed electron beam irradiation facility for radiation processing of food and medical products is being commissioned at our centre in Indore, India. Analysis of surface dose and uniformity for a pulsed beam facility is of crucial importance because it is influenced by various operating parameters such as beam current, pulse repetition rate (PRR), scanning current profile and frequency, scanning width and product conveying speed. A large number of experiments are required to determine the harmonized setting of these operating parameters for achieving uniform dose. Since there is no readily available tool to set these parameters, use of Monte Carlo methods and computational tools can prove to be the most viable and time saving technique to support the assessment of the dose distribution. In the present study, Monte Carlo code, MCNP, is used to simulate the transport of 10 MeV electron beam through various mediums coming into the beam path and generate an equivalent dose profile in a polystyrene phantom for stationary state. These results have been verified with experimentally measured dose profile, showing that results are in good agreement within 4%. The Monte Carlo simulation further has been used to optimize the overlapping between the successive pulses of a scan to achieve ± 5% dose uniformity along the scanning direction. A mathematical model, which uses the stationary state data, is developed to include the effect of conveyor speed. The algorithm of the model is discussed and the results are compared with the experimentally measured values, which show that the agreement is better than 15%. Finally, harmonized setting for operating parameters of the accelerator are derived to deliver uniform surface dose in the range of 1–13 kGy/pass.

  7. Measuring Pulse Rate Variability using Long-Range, Non-Contact Imaging Photoplethysmography

    Science.gov (United States)

    2016-08-20

    The quality of the recovered blood volume pulse morphology was sufficient to calculate time-domain measures of pulse rate using inter -pulse interval...rate using inter -pulse interval (IPI) time series. Following this, several features of pulse rate variability were calculated from the IPI time...interval time series was constructed consisting of inter -beat interval (IBI) and inter -pulse interval (IPI) time series for the ECG and PPG

  8. Strategy for stochastic dose-rate induced enhanced elimination of malignant tumour without dose escalation.

    Science.gov (United States)

    Paul, Subhadip; Roy, Prasun Kumar

    2016-09-01

    The efficacy of radiation therapy, a primary modality of cancer treatment, depends in general upon the total radiation dose administered to the tumour during the course of therapy. Nevertheless, the delivered radiation also irradiates normal tissues and dose escalation procedure often increases the elimination of normal tissue as well. In this article, we have developed theoretical frameworks under the premise of linear-quadratic-linear (LQL) model using stochastic differential equation and Jensen's inequality for exploring the possibility of attending to the two therapeutic performance objectives in contraposition-increasing the elimination of prostate tumour cells and enhancing the relative sparing of normal tissue in fractionated radiation therapy, within a prescribed limit of total radiation dose. Our study predicts that stochastic temporal modulation in radiation dose-rate appreciably enhances prostate tumour cell elimination, without needing dose escalation in radiation therapy. However, constant higher dose-rate can also enhance the elimination of tumour cells. In this context, we have shown that the sparing of normal tissue with stochastic dose-rate is considerably more than the sparing of normal tissue with the equivalent constant higher dose-rate. Further, by contrasting the stochastic dose-rate effects under LQL and linear-quadratic (LQ) models, we have also shown that the LQ model over-estimates stochastic dose-rate effect in tumour and under-estimates the stochastic dose-rate effect in normal tissue. Our study indicates the possibility of utilizing stochastic modulation of radiation dose-rate for designing enhanced radiation therapy protocol for cancer.

  9. Evaluation of Rectal Dose During High-Dose-Rate Intracavitary Brachytherapy for Cervical Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sha, Rajib Lochan [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Department of Physics, Osmania University, Hyderabad (India); Reddy, Palreddy Yadagiri [Department of Physics, Osmania University, Hyderabad (India); Rao, Ramakrishna [Department of Radiation Physics, MNJ Institute of Oncology and Regional Cancer Center, Hyderabad (India); Muralidhar, Kanaparthy R. [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2011-01-01

    High-dose-rate intracavitary brachytherapy (HDR-ICBT) for carcinoma of the uterine cervix often results in high doses being delivered to surrounding organs at risk (OARs) such as the rectum and bladder. Therefore, it is important to accurately determine and closely monitor the dose delivered to these OARs. In this study, we measured the dose delivered to the rectum by intracavitary applications and compared this measured dose to the International Commission on Radiation Units and Measurements rectal reference point dose calculated by the treatment planning system (TPS). To measure the dose, we inserted a miniature (0.1 cm{sup 3}) ionization chamber into the rectum of 86 patients undergoing radiation therapy for cervical carcinoma. The response of the miniature chamber modified by 3 thin lead marker rings for identification purposes during imaging was also characterized. The difference between the TPS-calculated maximum dose and the measured dose was <5% in 52 patients, 5-10% in 26 patients, and 10-14% in 8 patients. The TPS-calculated maximum dose was typically higher than the measured dose. Our study indicates that it is possible to measure the rectal dose for cervical carcinoma patients undergoing HDR-ICBT. We also conclude that the dose delivered to the rectum can be reasonably predicted by the TPS-calculated dose.

  10. Measurements of neutron dose rates with a balloon in Japan.

    Science.gov (United States)

    Nagaoka, K; Hiraide, I; Sato, K; Yamagami, T; Nakamura, T; Yabutani, T

    2007-01-01

    Measurements of cosmic-ray neutron dose rates with a balloon in Sanriku, Japan (geographic location: 39 degrees N, 142 degrees E; corresponding geomagnetic latitude: 30 degrees N) were conducted at an altitude from 0.2 to 25 km on 25-26 August 2004 when solar activity was at an average level. Neutron dose rates given as ambient dose equivalent rates (H(10)) were measured with high-sensitive neutron dose equivalent counters and electronic silicon personal dosimeters (EPDs). The neutron dose rates increased with increasing altitude, but they were saturated around 15-20 km and decreased with increasing altitude beyond 20 km. The neutron ambient dose equivalent rate was 1.5 microSv/h(- 1) at 20 km. Measured values were corrected for the deviation of the energy response of the dose equivalent counter from the fluence-to-ambient dose equivalent conversion coefficient, and the corrected values were very close to the calculated values with EPCARD. On the other hand, neutron measurements by the EPDs gave about 10 times overestimation because of the high sensitivity to cosmic-ray protons.

  11. ELDRS and dose-rate dependence of vertical NPN transistor

    Institute of Scientific and Technical Information of China (English)

    ZHENG Yu-Zhan; LU Wu; REN Di-Yuan; WANG Gai-Li; YU Xue-Feng; GUO Qi

    2009-01-01

    The enhanced low-dose-rate sensitivity (ELDRS) and dose-rate dependence of vertical NPN transistors are investigated in this article.The results show that the vertical NPN transistors exhibit more degradation at low dose rate,and that this degradation is attributed to the increase on base current.The oxide trapped positive charge near the SiO2-Si interface and interface traps at the interface can contribute to the increase on base current and the two-stage hydrogen mechanism associated with space charge effect can well explain the experimental results.

  12. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR (192)Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single (192)Ir source using their own equipment and local protocols. Results were compared to the (192)Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for (192)Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  13. Microfluidic Thrombosis under Multiple Shear Rates and Antiplatelet Therapy Doses

    Science.gov (United States)

    Ku, David N.; Forest, Craig R.

    2014-01-01

    The mainstay of treatment for thrombosis, the formation of occlusive platelet aggregates that often lead to heart attack and stroke, is antiplatelet therapy. Antiplatelet therapy dosing and resistance are poorly understood, leading to potential incorrect and ineffective dosing. Shear rate is also suspected to play a major role in thrombosis, but instrumentation to measure its influence has been limited by flow conditions, agonist use, and non-systematic and/or non-quantitative studies. In this work we measured occlusion times and thrombus detachment for a range of initial shear rates (500, 1500, 4000, and 10000 s−1) and therapy concentrations (0–2.4 µM for eptifibatide, 0–2 mM for acetyl-salicylic acid (ASA), 3.5–40 Units/L for heparin) using a microfluidic device. We also measured complete blood counts (CBC) and platelet activity using whole blood impedance aggregometry. Effects of shear rate and dose were analyzed using general linear models, logistic regressions, and Cox proportional hazards models. Shear rates have significant effects on thrombosis/dose-response curves for all tested therapies. ASA has little effect on high shear occlusion times, even at very high doses (up to 20 times the recommended dose). Under ASA therapy, thrombi formed at high shear rates were 4 times more prone to detachment compared to those formed under control conditions. Eptifibatide reduced occlusion when controlling for shear rate and its efficacy increased with dose concentration. In contrast, the hazard of occlusion from ASA was several orders of magnitude higher than that of eptifibatide. Our results show similar dose efficacy to our low shear measurements using whole blood aggregometry. This quantitative and statistically validated study of the effects of a wide range of shear rate and antiplatelet therapy doses on occlusive thrombosis contributes to more accurate understanding of thrombosis and to models for optimizing patient treatment. PMID:24404131

  14. Microfluidic thrombosis under multiple shear rates and antiplatelet therapy doses.

    Directory of Open Access Journals (Sweden)

    Melissa Li

    Full Text Available The mainstay of treatment for thrombosis, the formation of occlusive platelet aggregates that often lead to heart attack and stroke, is antiplatelet therapy. Antiplatelet therapy dosing and resistance are poorly understood, leading to potential incorrect and ineffective dosing. Shear rate is also suspected to play a major role in thrombosis, but instrumentation to measure its influence has been limited by flow conditions, agonist use, and non-systematic and/or non-quantitative studies. In this work we measured occlusion times and thrombus detachment for a range of initial shear rates (500, 1500, 4000, and 10000 s(-1 and therapy concentrations (0-2.4 µM for eptifibatide, 0-2 mM for acetyl-salicylic acid (ASA, 3.5-40 Units/L for heparin using a microfluidic device. We also measured complete blood counts (CBC and platelet activity using whole blood impedance aggregometry. Effects of shear rate and dose were analyzed using general linear models, logistic regressions, and Cox proportional hazards models. Shear rates have significant effects on thrombosis/dose-response curves for all tested therapies. ASA has little effect on high shear occlusion times, even at very high doses (up to 20 times the recommended dose. Under ASA therapy, thrombi formed at high shear rates were 4 times more prone to detachment compared to those formed under control conditions. Eptifibatide reduced occlusion when controlling for shear rate and its efficacy increased with dose concentration. In contrast, the hazard of occlusion from ASA was several orders of magnitude higher than that of eptifibatide. Our results show similar dose efficacy to our low shear measurements using whole blood aggregometry. This quantitative and statistically validated study of the effects of a wide range of shear rate and antiplatelet therapy doses on occlusive thrombosis contributes to more accurate understanding of thrombosis and to models for optimizing patient treatment.

  15. Dose Rate Calculations for Rotary Mode Core Sampling Exhauster

    CERN Document Server

    Foust, D J

    2000-01-01

    This document provides the calculated estimated dose rates for three external locations on the Rotary Mode Core Sampling (RMCS) exhauster HEPA filter housing, per the request of Characterization Field Engineering.

  16. VMATc: VMAT with constant gantry speed and dose rate

    Science.gov (United States)

    Peng, Fei; Jiang, Steve B.; Romeijn, H. Edwin; Epelman, Marina A.

    2015-04-01

    This article considers the treatment plan optimization problem for Volumetric Modulated Arc Therapy (VMAT) with constant gantry speed and dose rate (VMATc). In particular, we consider the simultaneous optimization of multi-leaf collimator leaf positions and a constant gantry speed and dose rate. We propose a heuristic framework for (approximately) solving this optimization problem that is based on hierarchical decomposition. Specifically, an iterative algorithm is used to heuristically optimize dose rate and gantry speed selection, where at every iteration a leaf position optimization subproblem is solved, also heuristically, to find a high-quality plan corresponding to a given dose rate and gantry speed. We apply our framework to clinical patient cases, and compare the resulting VMATc plans to idealized IMRT, as well as full VMAT plans. Our results suggest that VMATc is capable of producing treatment plans of comparable quality to VMAT, albeit at the expense of long computation time and generally higher total monitor units.

  17. Terrestrial gamma dose rates and physical-chemical properties of ...

    African Journals Online (AJOL)

    Terrestrial gamma dose rates and physical-chemical properties of farm soils ... African Journal of Environmental Science and Technology ... left a legacy derelict landscapes and impoverished agricultural farm lands in the Jos, Plateau Nigeria.

  18. Failures Of CMOS Devices At Low Radiation-Dose Rates

    Science.gov (United States)

    Goben, Charles A.; Price, William E.

    1990-01-01

    Method for obtaining approximate failure-versus-dose-rate curves derived from experiments on failures of SGS 4007 complementary metal oxide/semiconductor (CMOS) integrated circuits irradiated by Co60 and Cs137 radioactive sources.

  19. [Innovation in gynaecological brachytherapy: new technologies, pulse dose-rate brachytherapy, image, definition of new volumes of interest and their impact on dosimetry: application in a clinical research programme "STIC"].

    Science.gov (United States)

    Haie-Meder, C; Peiffert, D

    2006-11-01

    Brachytherapy plays a fundamental role in the therapeutic approach of patients with stage I-IV cervical carcinoma. Technical modalities have evolved during the last decades: stepping source technology, imaging modalities development, specially IMN, treatment planning system integrating 3D images. Images from CT-Scan and MRI have contributed to a better knowledge of tumoral extension and critical organs. CT and/or MRI compatible applicators allow a sectional image based approach with a better definition of tumour volume compared to traditional approaches. The introduction of 3D image based approach for GTV and CTV requires new definitions and a common language. In 2000, a working group within GEC-ESTRO was created to support 3D image based 3D treatment planning approach in cervix cancer BT. The task was to determine a common terminology enabling various groups to use a common language. Recommendations were described and proposed based on clinical experience and dosimetric concepts of different institutions. Two CTVs were described en relation to the risk for recurrence: high-risk CTV and intermediate risk CTV. In order to better define the role of such definitions and their potential impact on the complication incidence in patients with cervical cancer, a special French programme was developed. The aim of this programme is to study the incidence of the severe 2-year complication rate in two comparable patient populations: one population is treated using PDR brachytherapy with CT-Scan or MRI with the applicators in place allowing a 3D dosimetry with optimization, the second population is treated using standard X-rays radiographs without any delineation of the target nor optimisation. Each population arm includes 425 patients. A medicoeconomic assessment is performed, allowing a real cost of the most sophisticated approach compared to a historical dosimetric system.

  20. Analysis of ionic mobilities in liquid isooctane with low dose radiotherapy pulsed photon beams

    Science.gov (United States)

    Pardo-Montero, J.; Tegami, S.; Gago-Arias, A.; González-Castaño, D. M.; Holzscheiter, M. H.; Gómez, F.

    2012-09-01

    In this work we present a model of signal temporal development in ionization chambers and we use it to determine ionic mobilities and relative densities of charge carriers in non-ultrapure liquid isooctane using a liquid-filled ionization chamber dosimeter. The detector has been irradiated with a low dose rate, short pulsed photon beam generated with a medical LINAC. Ionic mobilities have been obtained by studying the temporal development of the readout signal and fitting it to a model for low dose rate beams where recombination is negligible. The best fit has been obtained for 3 ionic species with mobilities k1 = (2.22±0.22) × 10-8, k2 = (3.37±0.43) × 10-8, k3 = (19.69±2.59) × 10-8 m2 V-1 s-1 and relative densities n1 = 0.5 (n1 is not a fitting parameter), n2 = 0.23±0.03 and n3 = 0.27±0.03.

  1. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  2. Rate equation dynamics of passively mode-locked quasi-continuous lasers: pulse stability and dynamic pulse compression

    Energy Technology Data Exchange (ETDEWEB)

    New, G.H.C.; Orkney, K.E.; Nock, M.J.W.

    1976-09-01

    New theoretical results connected with the stability of multiple pulsing in a passively mode-locked quasicontinuous laser in the rate equation approximation are presented. Together with earlier results, these allow the number of pulses per cavity transit to be predicted and a qualitative estimate made of the pulse duration for any combination of parameters. The results are illustrated by computer evolutions.

  3. Real-time energy measurement of high repetition rate ultrashort laser pulses using pulse integration and FPGA processing.

    Science.gov (United States)

    Tang, Qi-Jie; Yang, Dong-Xu; Wang, Jian; Feng, Yi; Zhang, Hong-Fei; Chen, Teng-Yun

    2016-11-01

    Real-time energy measurement using pulse integration method for high repetition rate ultrashort laser pulses based on FPGA (Field-Programmable Gate Array) and high-speed pipeline ADC (Analog-to-Digital Convertor) is introduced in this paper. There are two parts contained in this method: pulse integration and real-time data processing. The pulse integration circuit will convert the pulse to the step type signals which are linear to the laser pulse energy. Through the real-time data processing part, the amplitude of the step signals will be obtained by ADC sampling and conducting calculation in real time in FPGA. The test result shows that the method with good linearity (4.770%) and without pulse measurement missing is suitable for ultrashort laser pulses with high repetition rate up to 100 MHz.

  4. Real-time energy measurement of high repetition rate ultrashort laser pulses using pulse integration and FPGA processing

    Science.gov (United States)

    Tang, Qi-jie; Yang, Dong-xu; Wang, Jian; Feng, Yi; Zhang, Hong-fei; Chen, Teng-yun

    2016-11-01

    Real-time energy measurement using pulse integration method for high repetition rate ultrashort laser pulses based on FPGA (Field-Programmable Gate Array) and high-speed pipeline ADC (Analog-to-Digital Convertor) is introduced in this paper. There are two parts contained in this method: pulse integration and real-time data processing. The pulse integration circuit will convert the pulse to the step type signals which are linear to the laser pulse energy. Through the real-time data processing part, the amplitude of the step signals will be obtained by ADC sampling and conducting calculation in real time in FPGA. The test result shows that the method with good linearity (4.770%) and without pulse measurement missing is suitable for ultrashort laser pulses with high repetition rate up to 100 MHz.

  5. The transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Bastin, K.T.; Podgorsak, M.B.; Thomadsen, B.R. (Univ. of Wisconsin Hospitals and Clinics, Madison, WI (United States))

    1993-07-15

    The purpose was to measure the transit dose produced by a moving high dose rate brachytherapy source and assess its clinical significance. The doses produced from source movement during Ir-192 HDR afterloading were measured using calibrated thermoluminescent dosimeter rods. Transit doses at distances of 0.5-4.0 cm from an endobronchial applicator were measured using a Lucite phantom accommodating 1 x 1 x 6 mm thermoluminescent rods. Surface transit dose measurements were made using esophageal and endobronchial catheters, a gynecologic tandem, and an interstitial needle. No difference was detected in thermoluminescent dosimeter rod responses to 4 MV and Ir-192 spectra (427 nC/Gy) in a range of dose between 2 and 300 cGy. The transit dose at 0.5 cm from an endobronchial catheter was 0.31 cGy/(Curie-fraction) and followed an inverse square fall-off with increasing distance. Surface transit doses ranged from 0.38 cGy/(Curie-fraction) for an esophageal catheter to 1.03 cGy/(Curie-fraction) for an endobronchial catheter. Source velocity is dependent on the interdwell distance and varies between 220-452 mm/sec. A numeric algorithm was developed to calculate total transit dose, and was based on a dynamic point approximation for the moving high dose rate source. This algorithm reliably predicted the empirical transit doses and demonstrated that total transit dose is dependent on source velocity, number of fractions, and source activity. Surface transit doses are dependent on applicator diameter and wall material and thickness. Total transit doses within or outside the desired treatment volume are typically <100 cGy, but may exceed 200 cGy when using a large number of fractions with a high activity source. 9 refs., 8 figs., 1 tab.

  6. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  7. Factors affecting high resting pulse rate in military pilots

    Directory of Open Access Journals (Sweden)

    Minarma Siagian

    2014-02-01

    Full Text Available AbstrakLatar belakang: Pilot terpajan pada keadaan yang memerlukan kewaspadaan yang meningkatkan kegiatan sistem saraf simpatis. Hal ini dapat berdampak pada sistem kardiovaskular manusia, yang antara lain tercermin pada peningkatan frekuensi denyut jantung. Penelitian bertujuan untuk mengetahui pengaruh beberapa faktor yang meningkatkan frekuensi denyut jantung pada pilot. Metode:Penelitian nested case-control yang dilakukan pada pilot militer yang melakukan pemeriksaan fisik tahunan di Lembaga Kesehatan Penerbangan dan Ruang Angkasa (LAKESPRA Saryanto dari tahun 2003 sampai 2008. Data yang diperoleh dari rekam medik berupa umur, pangkat, jumlah jam terbang, rata-rata jam terbang per tahun, dan jenis pesawat. Hasil: Dari 539 pilot, terdapat 155 pilot dengan frekuensi nadi istirahat tinggi. Dibandingkan dengan pilot berumur 23-29 tahun, pilot berumur 30-39 tahun mempunyai risiko 66% lebih banyak untuk frekuensi nadi istirahat tinggi [rasio odds suaian (ORa = 1,66; 95% interval kepercayaan (CI = 1,17-2,35, P = 0,004], sedangkan yang berumur 40-49 tahun berisiko 2,4 kali (ORa = 2,40; P = 0,000]. Dibandingkan pilot pesawat transport, pilot pesawat tempur berisiko 59% lebih banyak dengan frekuensi nadi istirahat tinggi (ORa = 1,59; P = 0,002. Kesimpulan:Umur pilot yang semakin tua dan jenis pesawat tempur meningkatkan risiko frekuensi nadi istirahat pada pilot. (Health Science Indones 2013;2:51-4Kata kunci:umur, jenis pesawat terbang, frekuensi nadi istirahat, pilotAbstractBackground:Pilots are almost constantly exposed to emergency situations which increase sympathetic activity. This will affect the cardiovascular system, which among others will be reflected by increased resting pulse rate. The aim of this study was to investigate factors that increase resting pulse rate in pilots. Methods:A nested case-control study was conducted on Indonesian Air Force military pilots doing annual medical check-ups at the Saryanto Institute for Medical and Health

  8. Neutron dose equivalent rate for heavy ion bombardment

    Institute of Scientific and Technical Information of China (English)

    LiGui-Sheng; ZhangTian-Mei; 等

    1998-01-01

    The fluence rate distribution of neutrons in the reactionsof 50MeV/u 18O-ion on thick Be,Cu and Au targets have been measured with an activation method of threshold detectors andthe neutron dose equivalent rate distributions at 1m from the tqrgets in intermediate energy heavy ion target area are obtained by using the conversion factors from neutron fluence rate to neutron doseequivalent rate.

  9. Equivalent dose rate by muons to the human body.

    Science.gov (United States)

    Băcioiu, I

    2011-11-01

    In this paper, the relative sensitivity from different human tissues of the human body, at a ground level, from muon cosmic radiation has been studied. The aim of this paper was to provide information on the equivalent dose rates received from atmospheric muons to human body, at the ground level. The calculated value of the effective dose rate by atmospheric muons plus the radiation levels of the natural annual background radiation dose, at the ground level, in the momentum interval of cosmic ray muon (0.2-120.0 GeV/c) is about 2.106±0.001 mSv/y, which is insignificant in comparison with the values of the doses from the top of the atmosphere.

  10. PRECEDENTS FOR AUTHORIZATION OF CONTENTS USING DOSE RATE MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Abramczyk, G.; Bellamy, S.; Nathan, S.; Loftin, B.

    2012-06-05

    For the transportation of Radioactive Material (RAM) packages, the requirements for the maximum allowed dose rate at the package surface and in its vicinity are given in Title 10 of the Code of Federal Regulations, Section 71.47. The regulations are based on the acceptable dose rates to which the public, workers, and the environment may be exposed. As such, the regulations specify dose rates, rather than quantity of radioactive isotopes and require monitoring to confirm the requirements are met. 10CFR71.47 requires that each package of radioactive materials offered for transportation must be designed and prepared for shipment so that under conditions normally incident to transportation the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external Surface of the package, and the transport index does not exceed 10. Before shipment, the dose rate of the package is determined by measurement, ensuring that it conforms to the regulatory limits, regardless of any analyses. This is the requirement for all certified packagings. This paper discusses the requirements for establishing the dose rates when shipping RAM packages and the precedents for meeting these requirements by measurement.

  11. Generation of low-timing-jitter femtosecond pulse trains with 2 GHz repetition rate via external repetition rate multiplication.

    Science.gov (United States)

    Chen, Jian; Sickler, Jason W; Fendel, Peter; Ippen, Erich P; Kärtner, Franz X; Wilken, Tobias; Holzwarth, Ronald; Hänsch, Theodor W

    2008-05-01

    Generation of low-timing-jitter 150 fs pulse trains at 1560 nm with 2 GHz repetition rate is demonstrated by locking a 200 MHz fundamental polarization additive-pulse mode-locked erbium fiber laser to high-finesse external Fabry-Perot cavities. The timing jitter and relative intensity noise of the repetition-rate multiplied pulse train are investigated.

  12. Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea.

    Science.gov (United States)

    Khandoker, Ahsan H; Karmakar, Chandan K; Palaniswami, Marimuthu

    2011-03-01

    We investigate whether pulse rate variability (PRV) extracted from finger photo-plethysmography (Pleth) waveforms can be the substitute of heart rate variability (HRV) from RR intervals of ECG signals during obstructive sleep apnea (OSA). Simultaneous measurements (ECG and Pleth) were taken from 29 healthy subjects during normal (undisturbed sleep) breathing and 22 patients with OSA during OSA events. Highly significant (pr>0.95) were found between heart rate (HR) and pulse rate (PR). Bland-Altman plot of HR and PR shows good agreement (sleep. However, several variability measures (SDNN, RMSSD, HF power, LF/HF and sample entropy) of PR and HR were found to be significantly (pheart rate variability under normal breathing in sleep but does not precisely reflect HRV in sleep disordered breathing.

  13. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    M.R. Germans; P.C. de Witt Hamer; L.J. van Boven; K.A.H. Zwinderman; G.J. Bouma

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  14. Remote Afterloading High Dose Rate Brachytherapy AMC EXPERIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Gyong; Chang, Hye Sook; Choi, Eun Kyong; Yi, Byong Yong [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1992-12-15

    Remote afterloading high dose rate brachytherapy(HDRB) is a new technology and needs new biological principle for time and dose schedule. Here, authors attempt to evaluate the technique and clinical outcome in 116 patients, 590 procedures performed at Asan Medical Center for 3 years. From Sep. 1985 to Aug 1992, 471 procedures of intracavitary radiation in 55 patients of cervical cancer and 26 of nasopharyngeal cancer, 79 intraluminal radiation in 12 of esophageal cancer, 11 of endobronchial cancer and 1 Klatskin tumor and 40 interstitial brachytherapy in 4 of breast cancer, 1 sarcoma and 1 urethral cancer were performed. Median follow-up was 7 months with range 1-31 months. All procedures except interstitial were performed under the local anesthesia and they were all well tolerated and completed the planned therapy except 6 patients. 53/58 patients with cervical cancer and 22/26 patients with nasopharynx cancer achieved CR. Among 15 patients with palliative therapy, 80% achieves palliation. We will describe the details of the technique and results in the text. To evaluate biologic effects of HDRB and optimal time/dose/fractionation schedule, we need longer follow-up. But authors feel that HDRB with proper fractionation schedule may yield superior results compared to the low dose rate brachytherapy considering the advantages of HDRB in safety factor for operator, better control of radiation dose and volume and patients comfort over the low dose brachytherapy.

  15. Pen harvester for powering a pulse rate sensor

    Energy Technology Data Exchange (ETDEWEB)

    Bedekar, Vishwas [Department of Materials Science and Engineering, UT Arlington, TX 76019 (United States); Oliver, Josiah; Priya, Shashank [CEHMS, Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24060 (United States)], E-mail: spriya@mse.vt.edu

    2009-05-21

    Rapid developments in the area of micro-sensors for various applications such as structural health monitoring, bio-chemical sensors and pressure sensors have increased the demand for portable, low cost, high efficiency energy harvesting devices. In this paper, we describe the scheme for powering a pulse rate sensor with a vibration energy harvester integrated inside a pen commonly carried by humans in the pocket close to the heart. Electromagnetic energy harvesting was selected in order to achieve high power at lower frequencies. The prototype pen harvester was found to generate 3 mW at 5 Hz and 1 mW at 3.5 Hz operating under displacement amplitude of 16 mm (corresponding to an acceleration of approximately 1.14 g{sub rms} at 5 Hz and 0.56 g{sub rms} at 3.5 Hz, respectively). A comprehensive mathematical modelling and simulations were performed in order to optimize the performance of the vibration energy harvester. The integrated pen harvester prototype was found to generate continuous power of 0.46-0.66 mW under normal human actions such as jogging and jumping which is enough for a small scale pulse rate sensor.

  16. A short pulse, high rep-rate microdischarge VUV source

    Science.gov (United States)

    Stephens, Jacob; Fierro, Andrew; Dickens, James; Neuber, Andreas; CenterPulsed Power; Power Electronics Team

    2013-09-01

    A MOSFET based high voltage pulser is utilized to excite a microdischarge (MD), or microdischarge array (MDA) with pulsed voltages of up to 1 kV, with risetime and FWHM on the order of 10 ns and 30 ns, respectively. Additionally, the pulser is capable of pulsing at rep-rates in excess of 35 MHz. However, for these experiments the rep-rate was set on the order of 1 MHz, so as to limit excess energy deposition into the background gas and optimize the energy efficiency of VUV generation. Using VUV capable spectral diagnostics, the VUV emission of the MDs for various pressures (50-800 + Torr) and gases, focused on argon, argon-hydrogen mixtures, and neon-hydrogen mixtures (all of which provide strong emission at λ VUV emission is characterized and compared to results from transient fluid modeling of the MDA. For instance, the MDA turn-on time is recorded to be about 15 ns, which matches the full plasma development time in the model, and the MDA self- capacitance largely determines the turn-off behavior. This research was supported by an AFOSR grant on the Physics of Distributed Plasma Discharges and fellowships from the National Physical Sciences Consortium, supported by Sandia National Laboratories.

  17. Pulse wave transit time for monitoring respiration rate.

    Science.gov (United States)

    Johansson, A; Ahlstrom, C; Lanne, T; Ask, P

    2006-06-01

    In this study, we investigate the beat-to-beat respiratory fluctuations in pulse wave transit time (PTT) and its subcomponents, the cardiac pre-ejection period (PEP) and the vessel transit time (VTT) in ten healthy subjects. The three transit times were found to fluctuate in pace with respiration. When applying a simple breath detecting algorithm, 88% of the breaths seen in a respiration air-flow reference could be detected correctly in PTT. Corresponding numbers for PEP and VTT were 76 and 81%, respectively. The performance during hypo- and hypertension was investigated by invoking blood pressure changes. In these situations, the error rates in breath detection were significantly higher. PTT can be derived from signals already present in most standard monitoring set-ups. The transit time technology thus has prospects to become an interesting alternative for respiration rate monitoring.

  18. Determination of dose rates from natural radionuclides in dental materials

    Energy Technology Data Exchange (ETDEWEB)

    Veronese, I. [Dipartimento di Fisica, Universita degli Studi di Milano, Milan (Italy) and INFN, Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Milan (Italy)]. E-mail: ivan.veronese@unimi.it; Guzzi, G. [AIRMEB - Italian Association for Metal and Biocompatibility Research, Milan (Italy); Giussani, A. [Dipartimento di Fisica, Universita degli Studi di Milano, Milan (Italy); INFN, Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Milan (Italy); Cantone, M.C. [Dipartimento di Fisica, Universita degli Studi di Milano, Milan (Italy); INFN, Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Milan (Italy); Ripamonti, D. [Dipartimento di Fisica, Universita degli Studi di Milano, Milan (Italy)

    2006-07-01

    Different types of materials used for dental prosthetics restoration, including feldspathic ceramics, glass ceramics, zirconia-based ceramics, alumina-based ceramics, and resin-based materials, were investigated with regard to content of natural radionuclides by means of thermoluminescence beta dosimetry and gamma spectrometry. The gross beta dose rate from feldspathic and glass ceramics was about ten times higher than the background measurement, whereas resin-based materials generated negligible beta dose rate, similarly to natural tooth samples. The specific activity of uranium and thorium was significantly below the levels found in the period when addition of uranium to dental porcelain materials was still permitted. The high-beta dose levels observed in feldspathic porcelains and glass ceramics are thus mainly ascribable to {sup 4}K, naturally present in these specimens. Although the measured values are below the recommended limits, results indicate that patients with prostheses are subject to higher dose levels than other members of the population. Alumina- and zirconia-based ceramics might be a promising alternative, as they have generally lower beta dose rates than the conventional porcelain materials. However, the dosimetry results, which imply the presence of inhomogeneously distributed clusters of radionuclides in the sample matrix, and the still unsuitable structural properties call for further optimization of these materials.

  19. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  20. Total dose and dose rate models for bipolar transistors in circuit simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Wix, Steven D.

    2013-05-01

    The objective of this work is to develop a model for total dose effects in bipolar junction transistors for use in circuit simulation. The components of the model are an electrical model of device performance that includes the effects of trapped charge on device behavior, and a model that calculates the trapped charge densities in a specific device structure as a function of radiation dose and dose rate. Simulations based on this model are found to agree well with measurements on a number of devices for which data are available.

  1. Patient release criteria for low dose rate brachytherapy implants.

    Science.gov (United States)

    Boyce, Dale E; Sheetz, Michael A

    2013-04-01

    A lack of consensus regarding a model governing the release of patients following sealed source brachytherapy has led to a set of patient release policies that vary from institution to institution. The U.S. Nuclear Regulatory Commission has issued regulatory guidance on patient release in NUREG 1556, Volume 9, Rev. 2, Appendix U, which allows calculation of release limits following implant brachytherapy. While the formalism presented in NUREG is meaningful for the calculation of release limits in the context of relatively high energy gamma emitters, it does not estimate accurately the effective dose equivalent for the common low dose rate brachytherapy sources Cs, I, and Pd. NUREG 1556 states that patient release may be based on patient-specific calculations as long as the calculation is documented. This work is intended to provide a format for patient-specific calculations to be used for the consideration of patients' release following the implantation of certain low dose rate brachytherapy isotopes.

  2. Dose rate of restroon in facilities using radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Gwi [Dept. of uclear Medicine, Inha University hospital, Incheon (Korea, Republic of); An, Seong Min [Dept. of Radiology, Gachon University, Incheon (Korea, Republic of)

    2016-06-15

    This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places−thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts−camera room, sedation room, and restroom−through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public−family care-givers, pregnant women, and children−be as far away from

  3. Effects of frame rate and image resolution on pulse rate measured using multiple camera imaging photoplethysmography

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.

    2015-03-01

    Non-contact, imaging photoplethysmography uses cameras to facilitate measurements including pulse rate, pulse rate variability, respiration rate, and blood perfusion by measuring characteristic changes in light absorption at the skin's surface resulting from changes in blood volume in the superficial microvasculature. Several factors may affect the accuracy of the physiological measurement including imager frame rate, resolution, compression, lighting conditions, image background, participant skin tone, and participant motion. Before this method can gain wider use outside basic research settings, its constraints and capabilities must be well understood. Recently, we presented a novel approach utilizing a synchronized, nine-camera, semicircular array backed by measurement of an electrocardiogram and fingertip reflectance photoplethysmogram. Twenty-five individuals participated in six, five-minute, controlled head motion artifact trials in front of a black and dynamic color backdrop. Increasing the input channel space for blind source separation using the camera array was effective in mitigating error from head motion artifact. Herein we present the effects of lower frame rates at 60 and 30 (reduced from 120) frames per second and reduced image resolution at 329x246 pixels (one-quarter of the original 658x492 pixel resolution) using bilinear and zero-order downsampling. This is the first time these factors have been examined for a multiple imager array and align well with previous findings utilizing a single imager. Examining windowed pulse rates, there is little observable difference in mean absolute error or error distributions resulting from reduced frame rates or image resolution, thus lowering requirements for systems measuring pulse rate over sufficient length time windows.

  4. Method of simulation of low dose rate for total dose effect in 0.18 {mu}m CMOS technology

    Energy Technology Data Exchange (ETDEWEB)

    He Baoping; Yao Zhibin; Guo Hongxia; Luo Yinhong; Zhang Fengqi; Wang Yuanming; Zhang Keying, E-mail: baopinghe@126.co [Northwest Institute of Nuclear Technology, Xi' an 710613 (China)

    2009-07-15

    Three methods for simulating low dose rate irradiation are presented and experimentally verified by using 0.18 {mu}m CMOS transistors. The results show that it is the best way to use a series of high dose rate irradiations, with 100 {sup 0}C annealing steps in-between irradiation steps, to simulate a continuous low dose rate irradiation. This approach can reduce the low dose rate testing time by as much as a factor of 45 with respect to the actual 0.5 rad (Si)/s dose rate irradiation. The procedure also provides detailed information on the behavior of the test devices in a low dose rate environment.

  5. Activation and Dose Rate Analysis of 316 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    XU; Zhi-long; SUN; Zheng; LIU; Xing-min; WAN; Hai-xia

    2012-01-01

    <正>In order to conduct research on 316 stainless steel to be used in reactors, neutron activation during irradiation and dose rate after irradiation in China Experiment Fast Reactor (CEFR) are calculated and analyzed. Based on 1 g of 316 stainless steel specimen, analysis on the activity of 316 stainless steel irradiated

  6. ACDOS2: an improved neutron-induced dose rate code

    Energy Technology Data Exchange (ETDEWEB)

    Lagache, J.C.

    1981-06-01

    To calculate the expected dose rate from fusion reactors as a function of geometry, composition, and time after shutdown a computer code, ACDOS2, was written, which utilizes up-to-date libraries of cross-sections and radioisotope decay data. ACDOS2 is in ANSI FORTRAN IV, in order to make it readily adaptable elsewhere.

  7. Total Dose Effects on Error Rates in Linear Bipolar Systems

    Science.gov (United States)

    Buchner, Stephen; McMorrow, Dale; Bernard, Muriel; Roche, Nicholas; Dusseau, Laurent

    2007-01-01

    The shapes of single event transients in linear bipolar circuits are distorted by exposure to total ionizing dose radiation. Some transients become broader and others become narrower. Such distortions may affect SET system error rates in a radiation environment. If the transients are broadened by TID, the error rate could increase during the course of a mission, a possibility that has implications for hardness assurance.

  8. Neodymium glass laser with a pulse energy of 220 J and a pulse repetition rate of 0.02 Hz

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmin, A A; Kulagin, O V; Khazanov, Efim A; Shaykin, A A [Institute of Applied Physics, Russian Academy of Sciences, Nizhnii Novgorod (Russian Federation)

    2013-07-31

    A compact neodymium glass laser with a pulse energy of 220 J and a record-high pulse repetition rate of 0.02 Hz (pulse duration 30 ns) is developed. Thermally induced phase distortions are compensated using wave phase conjugation. The integral depolarisation of radiation is decreased to 0.4% by using linear compensation schemes. The second harmonic of laser radiation can be used for pumping Ti : sapphire multipetawatt complexes. (letters)

  9. MRI-guided pulsed rate intracavitary curietherapy: preliminary results on 25 patients treated at the Tours University Hospital Centre; Curietherapie intracavitaire de debit pulse guidee par IRM: resultats preliminaires chez 25 patientes traitees au centre hospitalier universitaire de Tours

    Energy Technology Data Exchange (ETDEWEB)

    Ruffier-Loubiere, A.; Ouldamer, L.; Reynaud-Bougnoux, A.; Barillot, I. [CHU de Tours, 37 - Tours (France); Ouldamer, L.; Barillot, I. [Universite Francois-Rabelais, 37 - Tours (France)

    2010-10-15

    The authors report the assessment of the feasibility of a dose escalation when using MRI-guided pulsed rate intracavitary curietherapy with manual optimization of dwell times on 25 patients treated for an invasive cervical carcinoma. A first group of patients comprised 5 women with a stage Ib2 cancer who had only one curietherapy before surgical intervention. The second group comprises eleven women presenting limited stage Ib2 or IIa or IIb cancers who have been treated by a concomitant association of radiotherapy and chemotherapy followed by MRI-guided pulsed rate intracavitary curietherapy and later by surgical intervention. The third group comprised nine women presenting a locally advanced cancer who have been treated by chemotherapy followed by a MRI-guided pulsed rate intracavitary curietherapy. It appears that MRI-guided pulsed rate intracavitary curietherapy could be an efficient mean to increase the dose in the pelvic central part. Short communication

  10. Impact of surface curvature on dose delivery in intraoperative high-dose-rate brachytherapy.

    Science.gov (United States)

    Oh, Moonseong; Wang, Zhou; Malhotra, Harish K; Jaggernauth, Wainwright; Podgorsak, Matthew B

    2009-01-01

    In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas (5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

  11. Influence of the dose rate in the PVDF degradation processes

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Adriana S.M.; Pereira, Claubia, E-mail: adriananuclear@yahoo.com.br, E-mail: claubia@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Gual, Maritza R., E-mail: maritzargual@gmail.com [Instituto Superior de Tecnologias y Ciencias Aplicadas (InsTEC), Departamento de Ingenieria Nuclear, La Habana (Cuba); Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    Modification in polymeric structure of plastic material can be brought either by conventional chemical means or by exposure to ionization radiation from gamma radioactive sources or highly accelerated electrons. The prominent drawbacks of chemical cross-linking typically involve the generation by products such as peroxide degradation. Radiation cross-linking technologies include: application in cable and wire, application in rubber tyres, radiation vulcanization of rubber latex, polymer recycling, hydrogels etc. The degradation of PVDF polymer exposed to gamma irradiation in oxygen atmosphere in high dose rate has been studied and compared to obtained under smaller dose rates. The samples were irradiated with a Co-60 source at constant dose rate (12 kGy/h and 2,592 kGy/h), with doses ranging from 100 kGy to 3,000 kGy. Different dose rate determine the prevalence of the processes being evaluated in this work by thermal measurements and infrared spectroscopy. It is shown that the degradation processes involve chain scissions and crosslink formation. The formation of oxidation products was shown at the surface of the irradiated film. The FTIR data revealed absorption bands at 1730 and 1853 cm{sup -1} which were attributed to the stretch of C=O bonds, at 1715 and 1754 cm{sup -1} which were attributed to the C=C stretching and at 3518, 3585 and 3673 cm{sup -1} which were associated with NH stretch of NH{sub 2} and OH. Thermogravimetric studies reveal that the irradiation induced the increasing residues and decrease of the temperature of the decomposition start. (author)

  12. Patient-specific dose calculation methods for high-dose-rate iridium-192 brachytherapy

    Science.gov (United States)

    Poon, Emily S.

    In high-dose-rate 192Ir brachytherapy, the radiation dose received by the patient is calculated according to the AAPM Task Group 43 (TG-43) formalism. This table-based dose superposition method uses dosimetry parameters derived with the radioactive 192Ir source centered in a water phantom. It neglects the dose perturbations caused by inhomogeneities, such as the patient anatomy, applicators, shielding, and radiographic contrast solution. In this work, we evaluated the dosimetric characteristics of a shielded rectal applicator with an endocavitary balloon injected with contrast solution. The dose distributions around this applicator were calculated by the GEANT4 Monte Carlo (MC) code and measured by ionization chamber and GAFCHROMIC EBT film. A patient-specific dose calculation study was then carried out for 40 rectal treatment plans. The PTRAN_CT MC code was used to calculate the dose based on computed tomography (CT) images. This study involved the development of BrachyGUI, an integrated treatment planning tool that can process DICOM-RT data and create PTRAN_CT input initialization files. BrachyGUI also comes with dose calculation and evaluation capabilities. We proposed a novel scatter correction method to account for the reduction in backscatter radiation near tissue-air interfaces. The first step requires calculating the doses contributed by primary and scattered photons separately, assuming a full scatter environment. The scatter dose in the patient is subsequently adjusted using a factor derived by MC calculations, which depends on the distances between the point of interest, the 192Ir source, and the body contour. The method was validated for multicatheter breast brachytherapy, in which the target and skin doses for 18 patient plans agreed with PTRAN_CT calculations better than 1%. Finally, we developed a CT-based analytical dose calculation method. It corrects for the photon attenuation and scatter based upon the radiological paths determined by ray tracing

  13. TH-C-12A-07: Implementation of a Pulsed Low Dose Date Radiotherapy (PLRT) Protocol for Recurrent Cancers Using Advanced Beam Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Lin, M; Chen, L; Price, R [Fox Chase Cancer Center, Philadelphia, PA (United States); Li, J; Kang, S; Wang, P; Lang, J [Sichuan Provincial Cancer Hospital, Chengdu (China)

    2014-06-15

    Purpose: Recent in vitro and in vivo experimental findings provided strong evidence that pulsed low-dose-rate radiotherapy (PLDR) produced equivalent tumor control as conventional radiotherapy with significantly reduced normal tissue toxicities. This work aimed to implement a PLDR clinical protocol for the management of recurrent cancers utilizing IMRT and VMAT. Methods: Our PLDR protocol requires that the daily 2Gy dose be delivered in 0.2Gy×10 pulses with a 3min interval between the pulses. To take advantage of low-dose hyper-radiosensitivity the mean dose to the target is set at 0.2Gy and the maximum dose is limited to 0.4Gy per pulse. Practical planning strategies were developed for IMRT and VMAT: (1) set 10 ports for IMRT and 10 arcs for VMAT with each angle/arc as a pulse; (2) set the mean dose (0.2Gy) and maximum dose (0.4Gy) to the target per pulse as hard constraints (no constraints to OARs); (3) select optimal port/arc angles to avoid OARs; and (4) use reference structures in or around target/OARs to reduce maximum dose to the target/OARs. IMRT, VMAT and 3DCRT plans were generated for 60 H and N, breast, lung, pancreas and prostate patients and compared. Results: All PLDR treatment plans using IMRT and VMAT met the dosimetry requirements of the PLDR protocol (mean target dose: 0.20Gy±0.01Gy; maximum target dose < 0.4Gy). In comparison with 3DCRT, IMRT and VMAT exhibited improved target dose conformity and OAR dose sparing. A single arc can minimize the difference in the target dose due to multi-angle incidence although the delivery time is longer than 3DCRT and IMRT. Conclusion: IMRT and VMAT are better modalities for PLDR treatment of recurrent cancers with superior target dose conformity and critical structure sparing. The planning strategies/guidelines developed in this work are practical for IMRT/VMAT treatment planning to meet the dosimetry requirements of the PLDR protocol.

  14. Prototype Operational Advances for Atmospheric Radiation Dose Rate Specification

    Science.gov (United States)

    Tobiska, W. K.; Bouwer, D.; Bailey, J. J.; Didkovsky, L. V.; Judge, K.; Garrett, H. B.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R. W.; Bell, D.; Mertens, C. J.; Xu, X.; Crowley, G.; Reynolds, A.; Azeem, I.; Wiltberger, M. J.; Wiley, S.; Bacon, S.; Teets, E.; Sim, A.; Dominik, L.

    2014-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. The coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has developed innovative, new space weather observations that will become part of the toolset that is transitioned into operational use. One prototype operational system for providing timely information about the effects of space weather is SET's Automated Radiation Measurements for Aerospace Safety (ARMAS) system. ARMAS will provide the "weather" of the radiation environment to improve aircraft crew and passenger safety. Through several dozen flights the ARMAS project has successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time via Iridium satellites, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. We are extending the dose measurement domain above commercial aviation altitudes into the stratosphere with a collaborative project organized by NASA's Armstrong Flight Research Center (AFRC) called Upper-atmospheric Space and Earth Weather eXperiment (USEWX). In USEWX we will be flying on the ER-2 high altitude aircraft a micro dosimeter for

  15. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, T E; Norris, W P; Tolle, D V; Seed, T M; Poole, C M; Lombard, L S; Doyle, D E

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to /sup 60/Co ..gamma.. rays in a specially constructed facility. The exposure rates were either 5, 10, 17, or 35 R/day, and the exposures were terminated at either 600, 1400, 2000, or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD/sub 50/ for ..gamma..-ray exposures given at a number of exposure rates. They also allow comparison of the relative importance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD/sub 50/ for the beagle increases from 258 rad delivered at 15 R/minute to approximately 3000 rad at 10 R/day. Over this entire range, the LD/sub 50/ is dependent upon hematopoietic damage. At 5 R/day and less, no meaningful LD/sub 50/ can be determined; there is nearly normal continued hematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in other organ systems. Although the experiment is not complete, interim data allow several important conclusions. Terminated exposures, while not as effective as radiation continued until death, can produce myelogenous leukemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates are more damaging than higher rates on the basis of the rate and degree of hematological recovery that occurs after termination of irradiation. Thus, the rate of hematologic depression, the nadir of the depression, and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the former two are directly related to exposure rate.

  16. Coupling coefficient for TEA CO2 laser propulsion with variable pulse repetition rate

    Institute of Scientific and Technical Information of China (English)

    Yijun Zheng; Rongqing Tan; Donglei Wang; Guang Zheng; Changjun Ke; Kuohai Zhang; Chongyi Wan; Jin Wu

    2006-01-01

    @@ Because pulse repetition rate affected directly the momentum coupling coefficient of transversely excited atmospheric (TEA) CO2 laser propulsion, a double pulse trigger, controlling high voltage switch of laser excitation circuit, was designed. The pulse interval ranged between 5 and 100 ms. The momentum coupling coefficient for air-breathing mode laser propulsion was studied experimentally. It was found that the momentum coupling coefficient decreased with the pulse repetition rate increasing.

  17. Risk of solid cancer in low dose-rate radiation epidemiological studies and the dose-rate effectiveness factor.

    Science.gov (United States)

    Shore, Roy; Walsh, Linda; Azizova, Tamara; Rühm, Werner

    2017-10-01

    Estimated radiation risks used for radiation protection purposes have been based primarily on the Life Span Study (LSS) of atomic bomb survivors who received brief exposures at high dose rates, many with high doses. Information is needed regarding radiation risks from low dose-rate (LDR) exposures to low linear-energy-transfer (low-LET) radiation. We conducted a meta-analysis of LDR epidemiologic studies that provide dose-response estimates of total solid cancer risk in adulthood in comparison to corresponding LSS risks, in order to estimate a dose rate effectiveness factor (DREF). We identified 22 LDR studies with dose-response risk estimates for solid cancer after minimizing information overlap. For each study, a parallel risk estimate was derived from the LSS risk model using matching values for sex, mean ages at first exposure and attained age, targeted cancer types, and accounting for type of dosimetric assessment. For each LDR study, a ratio of the excess relative risk per Gy (ERR Gy(-1)) to the matching LSS ERR risk estimate (LDR/LSS) was calculated, and a meta-analysis of the risk ratios was conducted. The reciprocal of the resultant risk ratio provided an estimate of the DREF. The meta-analysis showed a LDR/LSS risk ratio of 0.36 (95% confidence interval [CI] 0.14, 0.57) for the 19 studies of solid cancer mortality and 0.33 (95% CI 0.13, 0.54) when three cohorts with only incidence data also were added, implying a DREF with values around 3, but statistically compatible with 2. However, the analyses were highly dominated by the Mayak worker study. When the Mayak study was excluded the LDR/LSS risk ratios increased: 1.12 (95% CI 0.40, 1.84) for mortality and 0.54 (95% CI 0.09, 0.99) for mortality + incidence, implying a lower DREF in the range of 1-2. Meta-analyses that included only cohorts in which the mean dose was radiation exposure. The LDR data provide direct evidence regarding risk from exposures at low dose rates as an important complement to the

  18. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D. [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  19. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo, E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, 46014 Valencia (Spain); Perez-Calatayud, Jose [Radiotherapy Department, La Fe University and Polytechnic Hospital, Valencia 46026 (Spain); Vijande, Javier [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and IFIC (UV-CSIC), Paterna 46980 (Spain); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2014-02-15

    Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For

  20. Combined scintillation detector for gamma dose rate measurement

    Energy Technology Data Exchange (ETDEWEB)

    Viererbl, L.; Novakova, O.; Jursova, L. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky)

    1990-01-01

    The specifications are described of a newly developed scintillation detector, essentially consisting of a plastic scintillator completed with inorganic scintillators ZnS(Ag) and NaI(Tl). The gamma dose rate is derived from the photomultiplier anode current. The composition and sizes of the scintillators and the capsule are selected so as to minimise the energy dependence errors and directional dependence errors of the detector response over a wide range of energies and/or angles. (author).

  1. Global shutdown dose rate maps for a DEMO conceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Leichtle, D., E-mail: dieter.leichtle@f4e.europa.eu [Karlsruhe Institute of Technology KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Pereslavtsev, P. [Karlsruhe Institute of Technology KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Sanz, J.; Catalan, J.P.; Juarez, R. [Universidad Nacional de Educación a Distancia(UNED), E.T.S. Ingenieros Industriales, C/ Juan del Rosal 12, 28040 Madrid (Spain)

    2015-10-15

    Highlights: • Application of R2S-method on high-resolution full torus sector mesh for DEMO. • Absorbed dose rates after shutdown for a variely of RH equipment at typical locations. • Idenification of radiation levels at several port based locations. - Abstract: For the calculations of highly reliable shutdown dose rate (SDR) maps in fusion devices like a DEMO plant, the Rigorous-2-step (R2S) method is nowadays routinely applied using high-resolution decay gamma sources from initial high-resolution neutron flux meshes activating all materials in the system. This approach has been utilized in the present paper with the objective to provide SDR results relevant for RH systems of a conceptual DEMO design developed in the EU. The primary objective was to assess specific locations of interest for RH equipment inside the vessel and along the extension of maintenance ports. To this end, a provisional DEMO MCNP model has been used, featuring HCLL-type blankets, tungsten/copper divertor, manifolds, vacuum vessel with ports and toroidal field coils. The operational scenario assumed 2.1 GW fusion power and a life-time of 20 years with plant availability of 30%, where removable parts will be extracted after 5.2 years. Results of absorbed dose rate distributions for several relevant materials are presented and discussed in terms of the different contributions from the various activated components.

  2. Supplementation of cobalt to UASB reactors by pulse dosing: CoCl2 versus CoEDTA(2-) pulses

    NARCIS (Netherlands)

    Fermoso, F.G.; Bartacek, J.; Chung, L.C.; Lens, P.N.L.

    2008-01-01

    The effect of chelation on the dosing strategy of cobalt to restore the performance of a cobalt limited methanol-fed bioreactor was investigated. Three upflow anaerobic sludge bed (UASB) reactors (30 degrees C, pH 7.0) were operated with methanol as the substrate at an organic loading rate of 8.5 g

  3. Physical characteristics of the Selectron high dose rate intracavitary afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Chenery, S.G.A.; Pla, M.; Podgorsak, E.B. (Royal Victoria Hospital, Montreal, Quebec (Canada); McGill Univ., Montreal, Quebec (Canada))

    1985-08-01

    The physics measurements on a Selectron high dose-rate afterloading cobalt-60 unit are reported. The installation was found to be acceptable from the standpoint of radiation safety and cost effectiveness; hospital bed space was saved as treatment could be on an outpatient basis. A source calibration 4% higher than the value stated by the manufacturer was obtained. Measurement of the ratio of exposure rate in water to that in air confirmed the calibration and the applicability of correction factors for routine clinical dosimetry recommended in the literature.

  4. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  5. Image-guided high dose rate endorectal brachytherapy.

    Science.gov (United States)

    Devic, Slobodan; Vuong, Té; Moftah, Belal; Evans, Michael; Podgorsak, Ervin B; Poon, Emily; Verhaegen, Frank

    2007-11-01

    Fractionated high dose rate endorectal brachytherapy (HDR-EBT) using CT-based treatment planning is an alternative method for preoperative down-sizing and down-staging of advanced rectal adeno-carcinomas. The authors present an image guidance procedure that was developed to ensure daily dose reproducibility for the four brachytherapy treatment fractions. Since the applicator might not be placed before each treatment fraction inside the rectal lumen in the same manner as it was placed during the 3D CT volume acquisition used for treatment planning, there is a shift along the catheter axis that may have to be performed. The required shift is determined by comparison of a daily radiograph with the treatment planning digitally-reconstructed radiograph (DRR). A procedure is developed for DRR reconstruction from the 3D data set used for the treatment planning, and two possible daily longitudinal shifts are illustrated: above and below the planning dose distribution. The authors also describe the procedure for rotational alignment illustrated on a clinical case. Reproduction of the treatment planned dose distribution on a daily basis is crucial for the success of fractionated 3D based brachytherapy treatments. Due to the cylindrical symmetry of the applicator used for preoperative HDR-EBT, two types of adjustments are necessary: applicator rotation and dwell position shift along the applicator's longitudinal axis. The impact of the longitudinal applicator shift prior to treatment delivery for 62 patients treated in our institution is also assessed.

  6. Spectrum analysis of all parameter noises in repetition-rate laser pulse train

    Institute of Scientific and Technical Information of China (English)

    Junhua Tang; Yuncai Wang

    2006-01-01

    @@ The theoretical investigation of all parameter noises in repetition-rate laser pulse train was presented. The expression of power spectrum of laser pulse trains with all parameter noises was derived, and the power spectra of pulse trains with different noise parameters were numerically simulated. By comparing the power spectra with and without pulse-width jitter, we noted that pulse-width jitter could not be neglected compared with amplitude noise and timing jitter and contributed a great amount of noise into the power spectrum under the condition that the product of pulse width and angular frequency was larger than 1.

  7. Sternal pulse rate variability compared with heart rate variability on healthy subjects.

    Science.gov (United States)

    Chreiteh, Shadi S; Belhage, Bo; Hoppe, Karsten; Branebjerg, Jens; Thomsen, Erik V

    2014-01-01

    The heart rate variability (HRV) is a commonly used method to quantify the sympathetic and the parasympathetic modulation of the heart rate. HRV is mainly conducted on electrocardiograms (ECG). However, the use of photo-plethysmography (PPG) as a marker of the autonomic tone is emerging. In this study we investigated the feasibility of deriving pulse rate variability (PRV) using PPG signals recorded by a reflectance PPG sensor attached to the chest bone (sternum) and comparing it to HRV. The recordings were conducted on 9 healthy subjects being in a relaxed supine position and under forced respiration, where the subjects were asked to breathe following a visual scale with a rate of 27 breaths/min. HRV parameters such as the mean intervals (meanNN), the standard deviation of intervals (SDNN), the root mean square of difference of successive intervals (RMSSD), and the proportion of intervals differing more than 50 ms (pNN50) were calculated from the R peak-to-R peak (R-R) and pulse-to-pulse (P-P) intervals. In the frequency domain the low and high frequency ratio of the power spectral density (LF/HF) was also computed. The Pearson correlation coefficient showed significant correlation for all the parameters (r > 0.95 with p < 0.001) and the Bland-Altmann analysis showed close agreement between the two methods for all the parameters during resting and forced respiration condition. Thus, PRV analysis using sternal PPG can be an alternative to HRV analysis on healthy subjects at.

  8. A comparative study of pulse rate variability and heart rate variability in healthy subjects.

    Science.gov (United States)

    Wong, Jih-Sen; Lu, Wan-An; Wu, Kung-Tai; Liu, Margaret; Chen, Gau-Yang; Kuo, Cheng-Deng

    2012-04-01

    Both heart rate variability (HRV) and pulse rate variability (PRV) are noninvasive means for the assessment of autonomic nervous control of the heart. However, it is not settled whether or not the PRV obtained from either hand can be the surrogate of HRV. The HRV measures obtained from electrocardiographic signals and the PRV measures obtained from the pulse waves recorded from the index fingers of both hands were compared in normal subjects by using linear regression analysis and Bland and Altman method. Highly significant correlations (P < 0.001, 0.89 < r < 1.0) were found between all HRV measures and the corresponding PRV measures of both hands. However, there were insufficient agreements in some measures between pairwise comparisons among HRV, right PRV and left PRV except heart rate and ultra-low frequency power (ULFP). The PRV of either hand is close to, but not the same as the HRV in healthy subjects. The HRV, right PRV and left PRV are not surrogates of one another in normal subjects except heart rate and ULFP. Since HRV is generally accepted as the standard method for the assessment of the autonomic nervous modulation of a subject, the PRV of either hand may not be suitable for the assessment of the cardiac autonomic nervous modulation of the subject.

  9. Dosimetry Modeling for Focal Low-Dose-Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Qaisieh, Bashar [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Mason, Josh, E-mail: joshua.mason@nhs.net [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Bownes, Peter; Henry, Ann [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Dickinson, Louise [Division of Surgery and Interventional Science, University College London, London (United Kingdom); Department of Radiology, Northwick Park Hospital, London North West NHS Trust, London (United Kingdom); Ahmed, Hashim U. [Division of Surgery and Interventional Science, University College London, London (United Kingdom); University College London Hospital, London (United Kingdom); Emberton, Mark [University College London Hospital, London (United Kingdom); Langley, Stephen [St Luke' s Cancer Centre, Guildford (United Kingdom)

    2015-07-15

    Purpose: Focal brachytherapy targeted to an individual lesion(s) within the prostate may reduce side effects experienced with whole-gland brachytherapy. The outcomes of a consensus meeting on focal prostate brachytherapy were used to investigate optimal dosimetry of focal low-dose-rate (LDR) prostate brachytherapy targeted using multiparametric magnetic resonance imaging (mp-MRI) and transperineal template prostate mapping (TPM) biopsy, including the effects of random and systematic seed displacements and interseed attenuation (ISA). Methods and Materials: Nine patients were selected according to clinical characteristics and concordance of TPM and mp-MRI. Retrospectively, 3 treatment plans were analyzed for each case: whole-gland (WG), hemi-gland (hemi), and ultra-focal (UF) plans, with 145-Gy prescription dose and identical dose constraints for each plan. Plan robustness to seed displacement and ISA were assessed using Monte Carlo simulations. Results: WG plans used a mean 28 needles and 81 seeds, hemi plans used 17 needles and 56 seeds, and UF plans used 12 needles and 25 seeds. Mean D90 (minimum dose received by 90% of the target) and V100 (percentage of the target that receives 100% dose) values were 181.3 Gy and 99.8% for the prostate in WG plans, 195.7 Gy and 97.8% for the hemi-prostate in hemi plans, and 218.3 Gy and 99.8% for the focal target in UF plans. Mean urethra D10 was 205.9 Gy, 191.4 Gy, and 92.4 Gy in WG, hemi, and UF plans, respectively. Mean rectum D2 cm{sup 3} was 107.5 Gy, 77.0 Gy, and 42.7 Gy in WG, hemi, and UF plans, respectively. Focal plans were more sensitive to seed displacement errors: random shifts with a standard deviation of 4 mm reduced mean target D90 by 14.0%, 20.5%, and 32.0% for WG, hemi, and UF plans, respectively. ISA has a similar impact on dose-volume histogram parameters for all plan types. Conclusions: Treatment planning for focal LDR brachytherapy is feasible. Dose constraints are easily met with a notable

  10. Advanced Computational Approaches for Characterizing Stochastic Cellular Responses to Low Dose, Low Dose Rate Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Bobby, R., Ph.D.

    2003-06-27

    applications of NEOTRANS2, indicate that nonlinear threshold-type, dose-response relationships for excess stochastic effects (problematic nonlethal mutations, neoplastic transformation) should be expected after exposure to low linear energy transfer (LET) gamma rays or gamma rays in combination with high-LET alpha radiation. Similar thresholds are expected for low-dose-rate low-LET beta irradiation. We attribute the thresholds to low-dose, low-LET radiation induced protection against spontaneous mutations and neoplastic transformations. The protection is presumed mainly to involve selective elimination of problematic cells via apoptosis. Low-dose, low-LET radiation is presumed to trigger wide-area cell signaling, which in turn leads to problematic bystander cells (e.g., mutants, neoplastically transformed cells) selectively undergoing apoptosis. Thus, this protective bystander effect leads to selective elimination of problematic cells (a tissue cleansing process in vivo). However, this protective bystander effects is a different process from low-dose stimulation of the immune system. Low-dose, low-LET radiation stimulation of the immune system may explain why thresholds for inducing excess cancer appear much larger (possibly more than 100-fold larger) than thresholds for inducing excess mutations and neoplastic transformations, when the dose rate is low. For ionizing radiation, the current risk assessment paradigm is such that the relative risk (RR) is always ¡Ý 1, no matter how small the dose. Our research results indicate that for low-dose or low-dose-rate, low-LET irradiation, RR < 1 may be more the rule than the exception. Directly tied to the current RR paradigm are the billion-dollar cleanup costs for radionuclide-contaminated DOE sites. Our research results suggest that continued use of the current RR paradigm for which RR ¡Ý 1 could cause more harm than benefit to society (e.g., by spreading unwarranted fear about phantom excess risks associated with low-dose low

  11. Advanced Computational Approaches for Characterizing Stochastic Cellular Responses to Low Dose, Low Dose Rate Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Bobby, R., Ph.D.

    2003-06-27

    applications of NEOTRANS2, indicate that nonlinear threshold-type, dose-response relationships for excess stochastic effects (problematic nonlethal mutations, neoplastic transformation) should be expected after exposure to low linear energy transfer (LET) gamma rays or gamma rays in combination with high-LET alpha radiation. Similar thresholds are expected for low-dose-rate low-LET beta irradiation. We attribute the thresholds to low-dose, low-LET radiation induced protection against spontaneous mutations and neoplastic transformations. The protection is presumed mainly to involve selective elimination of problematic cells via apoptosis. Low-dose, low-LET radiation is presumed to trigger wide-area cell signaling, which in turn leads to problematic bystander cells (e.g., mutants, neoplastically transformed cells) selectively undergoing apoptosis. Thus, this protective bystander effect leads to selective elimination of problematic cells (a tissue cleansing process in vivo). However, this protective bystander effects is a different process from low-dose stimulation of the immune system. Low-dose, low-LET radiation stimulation of the immune system may explain why thresholds for inducing excess cancer appear much larger (possibly more than 100-fold larger) than thresholds for inducing excess mutations and neoplastic transformations, when the dose rate is low. For ionizing radiation, the current risk assessment paradigm is such that the relative risk (RR) is always ¡Ý 1, no matter how small the dose. Our research results indicate that for low-dose or low-dose-rate, low-LET irradiation, RR < 1 may be more the rule than the exception. Directly tied to the current RR paradigm are the billion-dollar cleanup costs for radionuclide-contaminated DOE sites. Our research results suggest that continued use of the current RR paradigm for which RR ¡Ý 1 could cause more harm than benefit to society (e.g., by spreading unwarranted fear about phantom excess risks associated with low-dose low

  12. Variable dose rate single-arc IMAT delivered with a constant dose rate and variable angular spacing.

    Science.gov (United States)

    Tang, Grace; Earl, Matthew A; Yu, Cedric X

    2009-11-07

    Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these techniques are evenly distributed within an arc and are allowed to have different monitor unit (MU) weightings. Therefore, a variable dose-rate (VDR) is required for delivery. Because the VDR requirement complicates the control hardware and software of the linear accelerators (linacs) and prevents most existing linacs from delivering IMAT, we propose an alternative planning approach for IMAT using constant dose-rate (CDR) delivery with variable angular spacing. We prove the equivalence by converting VDR-optimized RapidArc plans to CDR plans, where the evenly spaced beams in the VDR plan are redistributed to uneven spacing such that the segments with larger MU weighting occupy a greater angular interval. To minimize perturbation in the optimized dose distribution, the angular deviation of the segments was restricted to single gantry sweep as in the VDR plans but each sector was delivered with a different value of CDR. For four patient cases, including two head-and-neck, one brain and one prostate, all CDR plans developed with the variable spacing scheme produced similar dose distributions to the original VDR plans. For plans with complex angular MU distributions, the number of sectors increased up to four in the CDR plans in order to maintain the original plan quality. Since each sector was delivered with a different dose rate, extra mode-up time (xMOT) was needed between the transitions of the successive sectors during delivery. On average, the delivery times of the CDR plans were approximately less than 1 min longer than the treatment times of the VDR plans, with an average of

  13. Radon exhalation rates and gamma doses from ceramic tiles.

    Science.gov (United States)

    O'Brien, R S; Aral, H; Peggie, J R

    1998-12-01

    This study was carried out to assess the possible radiological hazard resulting from the use of zircon in glaze applied to tiles used in buildings. The 226Ra content of various stains and glazing compounds was measured using gamma spectroscopy and the 222Rn exhalation rates for these materials were measured using adsorption on activated charcoal. The radon exhalation rates were found to be close to or less than the minimum detectable values for the equipment used. This limit was much lower than the estimated exhalation rates, which were calculated assuming that the parameters controlling the emanation and diffusion of 222Rn in the materials studied were similar to those of soil. This implied that the 222Rn emanation coefficients and/or diffusion coefficients for most of the materials studied were very much lower than expected. Measurements on zircon powders showed that the 222Rn emanation coefficient for zircon was much lower than that for soil, indicating that only a small fraction of the 222Rn produced by the decay of 226Ra was able to escape from the zircon grains. The estimated increase in radon concentration in room air and the estimated external gamma radiation dose resulting from the use of zircon glaze are both much lower than the relevant action level and dose limit.

  14. Reaction rate theory of radiation exposure: Effects of the dose rate on mutation frequencies

    CERN Document Server

    Manabe, Yuichiro; Nakamura, Issei

    2014-01-01

    We develop a kinetic reaction model for the cells having the irradiated DNA molecules due to the ionizing radiation exposure. Our theory simultaneously accounts for the time-dependent reactions of the DNA damage, the DNA mutation, the DNA repair, and the proliferation and apoptosis of cells in a tissue with a minimal set of model parameters. In contrast to the existing theories for the radiation exposition, we do not assume the relationships between the total dose and the induced mutation frequency. We show good agreement between theory and experiment. Importantly, our result shows a new perspective that the key ingredient in the study of the irradiated cells is the rate constants depending on the dose rate. Moreover, we discuss the universal scaling function for mutation frequencies due to the irradiation at low dose rates.

  15. Radiological mapping of Kelantan, Malaysia, using terrestrial radiation dose rate.

    Science.gov (United States)

    Garba, Nuraddeen Nasiru; Ramli, Ahmad Termizi; Saleh, Muneer Aziz; Sanusi, Syazwan Mohd; Gabdo, Hamman Tukur

    2016-06-01

    Measurements of the environmental terrestrial gamma radiation dose rate (TGRD) in each district of Kelantan state, Malaysia, were carried out using a portable hand-held radiation survey meter and global positioning system. The measurements were done based on geology and soil types of the area. The mean TGRD was found to be 209 nGy h(-1). Few areas of relatively enhanced activity were observed in Pasir Mas, Tanah Merah and Jeli districts, which have a mean TGRD between 300 and 500 nGy h(-1). An isodose map of the area was produced using ArcGIS software version 9.3.

  16. VARIABLE FIRING RATE OIL BURNER USING PULSE FUEL FLOW CONTROL.

    Energy Technology Data Exchange (ETDEWEB)

    KRISHNA,C.R.; BUTCHER,T.A.; KAMATH,B.R.

    2004-10-01

    problem is to develop a burner, which can operate at two firing rates, with the lower rate being significantly lower than 0.5 gallons per hour. This paper describes the initial results of adopting this approach through a pulsed flow nozzle. It has been shown that the concept of flow modulation with a small solenoid valve is feasible. Especially in the second configuration tested, where the Lee valve was integrated with the nozzle, reasonable modulation in flow of the order of 1.7 could be achieved. For this first prototype, the combustion performance is still not quite satisfactory. Improvements in operation, for example by providing a sharp and positive shut-off so that there is no flow under low pressures with consequent poor atomization could lead to better combustion performance. This could be achieved by using nozzles that have shut off or check valves for example. It is recommended that more work in cooperation with the valve manufacturer could produce a technically viable system. Marketability is of course a far more complex problem to be addressed once a technically viable product is available.

  17. Dose and dose-rate effects of ionizing radiation: a discussion in the light of radiological protection

    Energy Technology Data Exchange (ETDEWEB)

    Ruehm, Werner [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Neuherberg (Germany); Woloschak, Gayle E. [Northwestern University, Department of Radiation Oncology, Feinberg School of Medicine, Chicago, IL (United States); Shore, Roy E. [Radiation Effects Research Foundation (RERF), Hiroshima City (Japan); Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Grosche, Bernd [Federal Office for Radiation Protection, Oberschleissheim (Germany); Niwa, Ohtsura [Fukushima Medical University, Fukushima (Japan); Akiba, Suminori [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Epidemiology and Preventive Medicine, Kagoshima City (Japan); Ono, Tetsuya [Institute for Environmental Sciences, Rokkasho, Aomori-ken (Japan); Suzuki, Keiji [Nagasaki University, Department of Radiation Medical Sciences, Atomic Bomb Disease Institute, Nagasaki (Japan); Iwasaki, Toshiyasu [Central Research Institute of Electric Power Industry (CRIEPI), Radiation Safety Research Center, Nuclear Technology Research Laboratory, Tokyo (Japan); Ban, Nobuhiko [Tokyo Healthcare University, Faculty of Nursing, Tokyo (Japan); Kai, Michiaki [Oita University of Nursing and Health Sciences, Department of Environmental Health Science, Oita (Japan); Clement, Christopher H.; Hamada, Nobuyuki [International Commission on Radiological Protection (ICRP), PO Box 1046, Ottawa, ON (Canada); Bouffler, Simon [Public Health England (PHE), Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot (United Kingdom); Toma, Hideki [JAPAN NUS Co., Ltd. (JANUS), Tokyo (Japan)

    2015-11-15

    The biological effects on humans of low-dose and low-dose-rate exposures to ionizing radiation have always been of major interest. The most recent concept as suggested by the International Commission on Radiological Protection (ICRP) is to extrapolate existing epidemiological data at high doses and dose rates down to low doses and low dose rates relevant to radiological protection, using the so-called dose and dose-rate effectiveness factor (DDREF). The present paper summarizes what was presented and discussed by experts from ICRP and Japan at a dedicated workshop on this topic held in May 2015 in Kyoto, Japan. This paper describes the historical development of the DDREF concept in light of emerging scientific evidence on dose and dose-rate effects, summarizes the conclusions recently drawn by a number of international organizations (e.g., BEIR VII, ICRP, SSK, UNSCEAR, and WHO), mentions current scientific efforts to obtain more data on low-dose and low-dose-rate effects at molecular, cellular, animal and human levels, and discusses future options that could be useful to improve and optimize the DDREF concept for the purpose of radiological protection. (orig.)

  18. Analysis of the spatial rates dose rates during dental panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jong Kyung [Dept. of Radiation Safety Management Commission, Daegu Health College, Daegu (Korea, Republic of); Park, Myeong Hwan [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of); Kim, Yong Min [Dept. of Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2016-12-15

    A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a 45°, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is 3,840 μSv/h, which is four times higher than the lowest level 778 μSv/h. Furthermore, the spatial dose rate was 408 μSv/h on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

  19. Repetition rate tunable ultra-short optical pulse generation based on electrical pattern generator

    Institute of Scientific and Technical Information of China (English)

    Xin Fu; Hongming Zhang; Meng Yan; Minyu Yao

    2009-01-01

    @@ An actively mode-locked laser with tunable repetition rate is proposed and experimentally demonstrated based on a programmable electrical pattern generator.By changing the repetition rate of the electrical patterns applied on the in-cavity modulator, the repetition rate of the output optical pulse sequences changes accordingly while the pulse width of the optical pulse train remains almost constant.In other words, the output ultra-short pulse train has a tunable duty cycle.In a proof-of-principle experiment, optical pulses with repetition rates of 10, 5, 2.5 and 1.25 GHz are obtained by adjusting the electrical pattern applied on the in-cavity modulator while their pulse widths remain almost unchanged.

  20. Neutron and gamma ray total dose rate determination using anisn

    Science.gov (United States)

    Amin, E.; Ashoub, N.; Elkady, A.

    1994-07-01

    The National Center for Nuclear Safety and Radiation Control is in the process of acquiring a computer software library based mainly on internationally widely used computer codes. These codes are to be used as basic tools in safety analysis and radiation control and risk assessment. A complementary part of this activity is to validate the computer codes and set standard procedures with the limits of confidence for the different areas of applications of the one or the other code or set of codes. The present work has been then initiated in order to develop a standard shielding calculating procedure to be applied for the different applications of interest to the center, namely: shielding of nuclear installations, such as the ET-RR-1 reactor, the gamma unit, nuclear accelerator, radiotherapy units; shielding of nuclear sources (mainly neutron and gamma sources); shielding of transportation containers. In developing such a standard method, the sources of error to the final results (i.e. the dose rate and dose rate distribution) have to been identified and the error to be quantified. Through applying the developed procedure to benchmark PWR shielding problems, and to documented results for fission sources in water and concrete, the levels of confidence of the procedure in different application areas have been set.

  1. Neutron and gamma ray total dose rate determination using ANISN

    Energy Technology Data Exchange (ETDEWEB)

    Amin, E.; Elkady, A. [Atomic Energy Authority, Cairo (Egypt). National Center for Nuclear Safety and Radiation Control; Ashoub, N. [Nuclear Research Center, Cairo (Egypt)

    1994-07-01

    The National Center for Nuclear Safety and Radiation Control is in the process of acquiring a computer software library based mainly on internationally widely used computer codes. These codes are to be used as basic tools in safety analysis and radiation control and risk assessment. A complementary part of this activity is to validate the computer codes and set standard procedures with the limits of confidence for the different areas of applications of the one or the other code or set of codes. The present work has been then initiated in order to develop a standard shielding calculating procedure to be applied for the different applications of interest to the center, namely: shielding of nuclear installations, such as the ET-RR-1 reactor, the gamma unit, nuclear accelerator, radiotherapy units; shielding of nuclear sources (mainly neutron and gamma sources); shielding of transportation containers. In developing such a standard method, the sources of error to the final results (i.e. the dose rate and dose rate distribution) have to be identified and the error to be quantified. Through applying the developed procedure to benchmark PWR shielding problems, and to documented results for fission sources in water and concrete, the levels of confidence of the procedure in different application areas have been set. (author).

  2. Pulsed pumped Yb-doped fiber amplifier at low repetition rate

    Institute of Scientific and Technical Information of China (English)

    Changgeng Ye; Ping Yan; Mali Gong; Ming Lei

    2005-01-01

    A pulsed pumped Yb-doped double-clad fiber (DCF) master-oscillator power amplifier (MOPA) at low repetition rate is reported. Seeded by a passive Q-switched Nd:YAG microchip laser, the fiber amplifier can generate 167-kW peak-power and 0.83-ns duration pulses at 200-Hz repetition rate. Because of the pulsed pump approach, the amplified spontaneous emission (ASE) and the spurious lasing between pulses are well avoided, and the repetition rate can be set freely from single-shot to 1 kHz. Peak power scaling limitations that arise from the fiber facet damage are discussed.

  3. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Directory of Open Access Journals (Sweden)

    Daniel G Zhang

    Full Text Available MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF and conventional flattened 6MV photon beams were used. High dose rate (HDR brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL would be needed.

  4. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Science.gov (United States)

    Zhang, Daniel G; Feygelman, Vladimir; Moros, Eduardo G; Latifi, Kujtim; Zhang, Geoffrey G

    2014-01-01

    MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF) and conventional flattened 6MV photon beams were used. High dose rate (HDR) brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL) would be needed.

  5. Using a Calculated Pulse Rate with an Artificial Neural Network to Detect Irregular Interbeats.

    Science.gov (United States)

    Yeh, Bih-Chyun; Lin, Wen-Piao

    2016-03-01

    Heart rate is an important clinical measure that is often used in pathological diagnosis and prognosis. Valid detection of irregular heartbeats is crucial in the clinical practice. We propose an artificial neural network using the calculated pulse rate to detect irregular interbeats. The proposed system measures the calculated pulse rate to determine an "irregular interbeat on" or "irregular interbeat off" event. If an irregular interbeat is detected, the proposed system produces a danger warning, which is helpful for clinicians. If a non-irregular interbeat is detected, the proposed system displays the calculated pulse rate. We include a flow chart of the proposed software. In an experiment, we measure the calculated pulse rates and achieve an error percentage of pulse rates to detect irregular interbeats, we find such irregular interbeats in eight participants.

  6. Influence of the pulse duration and the experimental approach onto the specific removal rate for ultra-short pulses

    Science.gov (United States)

    Jaeggi, B.; Neuenschwander, B.; Remund, S.; Kramer, T.

    2017-02-01

    To be competitive in industrial applications the throughput is a key factor in laser micro machining using ultra-short pulsed laser systems. Both, ps and fs laser systems are suitable for industrial applications. Therefore one has to choose the right pulse duration for highest ablation efficiency. As shown in earlier publications the efficiency of the ablation process can be described by the specific removal rate, which has a maximum value at an optimum fluence. But its value often bases on a calculation using the threshold fluence and energy penetration depth deduced by measuring the depth of ablated cavities machined with different fluences and number of pulses. But this calculated specific removal rate often differs from the one deduced from ablated squares as recently shown in literature. Further an unexpected drop of the specific removal rate was reported for stainless steel when the pulse duration was reduced from 900 fs to 400 fs. Thus the influence of the pulse duration in the fs and low ps regime onto the specific removal rate is investigated with different methods for industrial relevant materials

  7. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Directory of Open Access Journals (Sweden)

    Zhenxing Liu

    Full Text Available OBJECTIVE: To compare the efficacy and safety of high dose rate (HDR and low dose rate (LDR brachytherapy in treating early-stage oral cancer. DATA SOURCES: A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies. STUDY SELECTION: Only randomized controlled trials (RCT and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III were of interest. DATA EXTRACTION AND SYNTHESIS: Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01, overall mortality (OR = 1.01, CI 95% 0.61-1.66 and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42. CONCLUSIONS: This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  8. ACDOS3: a further improved neutron dose-rate code

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.S.

    1982-07-01

    ACD0S3 is a computer code designed primarily to calculate the activities and dose rates produced by neutron activation in a variety of simple geometries. Neutron fluxes, in up to 50 groups and with energies up to 20 MeV, must be supplied as part of the input data. The neutron-source strength must also be supplied, or alternately, the code will compute it from neutral-beam operating parameters in the case where the source is a fusion-reactor injector. ACD0S3 differs from the previous version ACD0S2 in that additional geometries have been added, the neutron cross-section library has been updated, an estimate of the energy deposited by neutron reactions has been provided, and a significant increase in efficiency in reading the data libraries has been incorporated.

  9. Development of a phoswich detector for neutron dose rate measurements in the Earth's atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Doensdorf, Esther Miriam

    2014-04-30

    The Earth is constantly exposed to a stream of energetic particles from outer space. Through the interaction of this radiation with the Earth's magnetosphere and atmosphere a complex radiation field is formed which varies with the location inside the Earth's atmosphere. This radiation field consists of charged and uncharged particles leading to the constant exposure of human beings to radiation. As this ionizing radiation can be harmful for humans, it is necessary to perform dose rate measurements in different altitudes in the Earth's atmosphere. Due to their higher biological effectiveness the exposure to neutrons is more harmful than the exposure to γ-rays and charged particles, which is why the determination of neutron dose rates is the focus of this work. In this work the prototype of a Phoswich detector called PING (Phoswich Instrument for Neutrons and Gammas) is developed to determine dose rates caused by neutrons in the Earth's atmosphere and to distinguish these from γ-rays. The instrument is composed of two different scintillators optically coupled to each other and read out by one common photomultiplier tube. The scintillator package consists of an inner plastic scintillator made of the material BC-412 and a surrounding anti-coincidence made of sodium doped caesium iodide (CsI(Na)). In this work the instrument is calibrated, tested and flown and a procedure for a pulse shape analysis for this instrument is developed. With this analysis it is possible to distinguish pulses from the plastic scintillator and pulses from the CsI(Na). The pulses from the plastic scintillator are mainly due to the interaction of neutrons but there is an energy-dependent contribution of γ-rays to these events. Measurements performed on board an airplane show that the dose rates measured with the developed detector are in the same order of magnitude as results of other instruments. During measurements on board stratospheric balloons the altitude dependence

  10. Validation of pulse rate variability as a surrogate for heart rate variability in chronically instrumented rabbits.

    Science.gov (United States)

    Pellegrino, Peter R; Schiller, Alicia M; Zucker, Irving H

    2014-07-01

    Heart rate variability (HRV) is a function of cardiac autonomic tone that is widely used in both clinical and animal studies. In preclinical studies, HRV measures are frequently derived using the arterial pulse waveform from an implanted pressure telemetry device, termed pulse rate variability (PRV), instead of the electrocardiogram signal in accordance with clinical guidelines. The acceptability of PRV as a surrogate for HRV in instrumented animals is unknown. Using rabbits implanted with intracardiac leads and chronically implanted pressure transducers, we investigated the correlation and agreement of time-domain, frequency-domain, and nonlinear indexes of HRV and PRV at baseline. We also investigated the effects of ventricular pacing and autonomic blockade on both measures. At baseline, HRV and PRV time- and frequency-domain parameters showed robust correlations and moderate to high agreement, whereas nonlinear parameters showed slightly weaker correlations and varied agreement. Ventricular pacing almost completely eliminated HRV, and spectral analysis of the PRV signal revealed a HRV-independent rhythm. After cardiac autonomic blockade with atropine or metoprolol, the changes in time- and non-normalized frequency-domain measures of PRV continued to show strong correlations and moderate to high agreement with corresponding changes in HRV measures. Blockade-induced changes in nonlinear PRV indexes correlated poorly with HRV changes and showed weak agreement. These results suggest that time- and frequency-domain measures of PRV are acceptable surrogates for HRV even in the context of changing cardiac autonomic tone, but caution should be used when nonlinear measures are a primary end point or when HRV is very low as HRV-independent rhythms may predominate.

  11. Single-pulse dynamics and flow rates of inertial micropumps

    CERN Document Server

    Govyadinov, A N; Markel, D P; Torniainen, E D

    2015-01-01

    Bubble-driven inertial pumps are a novel method of moving liquids through microchannels. We combine high-speed imaging, computational fluid dynamics (CFD) simulations and an effective one-dimensional model to study the fundamentals of inertial pumping. Single-pulse flow through 22 x 17 um2 U-shaped channels containing 4-um polystyrene tracer beads has been imaged with a high-speed camera. The results are used to calibrate the CFD and one-dimensional models to extract an effective bubble strength. Then the frequency dependence of inertial pumping is studied both experimentally and numerically. The pump efficiency is found to gradually decrease once the successive pulses start to overlap in time.

  12. Left ventricular ejection time, not heart rate, is an independent correlate of aortic pulse wave velocity.

    Science.gov (United States)

    Salvi, Paolo; Palombo, Carlo; Salvi, Giovanni Matteo; Labat, Carlos; Parati, Gianfranco; Benetos, Athanase

    2013-12-01

    Several studies showed a positive association between heart rate and pulse wave velocity, a sensitive marker of arterial stiffness. However, no study involving a large population has specifically addressed the dependence of pulse wave velocity on different components of the cardiac cycle. The aim of this study was to explore in subjects of different age the link between pulse wave velocity with heart period (the reciprocal of heart rate) and the temporal components of the cardiac cycle such as left ventricular ejection time and diastolic time. Carotid-femoral pulse wave velocity was assessed in 3,020 untreated subjects (1,107 men). Heart period, left ventricular ejection time, diastolic time, and early-systolic dP/dt were determined by carotid pulse wave analysis with high-fidelity applanation tonometry. An inverse association was found between pulse wave velocity and left ventricular ejection time at all ages (pulse wave velocity and heart period was also found, with the exception of the youngest subjects (P = 0.20). A significant positive correlation was also found between pulse wave velocity and dP/dt (P pulse wave velocity at all ages, whereas the contribution of heart period no longer became significant. Our data demonstrate that pulse wave velocity is more closely related to left ventricular systolic function than to heart period. This may have methodological and pathophysiological implications.

  13. Gamma spectrum, count rate, and dose rate measurements of the Columbia riverbank from Vernita to Sacajawea

    Energy Technology Data Exchange (ETDEWEB)

    Grande, L.A.

    1966-01-31

    The purpose of this study was to evaluate radiological conditions that exist on the riverbank of the Columbia River. Included was a comparative study of the suitability of three instruments to measure the dose rates. These instruments were a NaI (T1) scintillation counter normally used for aerial monitoring, a bioplastic scintillation counter normally used as a road monitor, and a portable 40 liter ionization chamber normally used to measure very low gamma dose rates. The selection of representative sites for the comparative study was based on an initial GM survey of the general areas in question. Seven sites were studied--from Vernita Ferry Landing above the Hanford project to Sacajawea Park below Pasco.

  14. Pulse rate variability compared with Heart Rate Variability in children with and without sleep disordered breathing.

    Science.gov (United States)

    Dehkordi, Parastoo; Garde, Ainara; Karlen, Walter; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2013-01-01

    Heart Rate Variability (HRV), the variation of time intervals between heartbeats, is one of the most promising and widely used quantitative markers of autonomic activity. Traditionally, HRV is measured as the series of instantaneous cycle intervals obtained from the electrocardiogram (ECG). In this study, we investigated the estimation of variation in heart rate from a photoplethysmography (PPG) signal, called pulse rate variability (PRV), and assessed its accuracy as an estimate of HRV in children with and without sleep disordered breathing (SDB). We recorded raw PPGs from 72 children using the Phone Oximeter, an oximeter connected to a mobile phone. Full polysomnography including ECG was simultaneously recorded for each subject. We used correlation and Bland-Altman analysis for comparing the parameters of HRV and PRV between two groups of children. Significant correlation (r > 0.90, p < 0.05) and close agreement were found between HRV and PRV for mean intervals, standard deviation of intervals (SDNN) and the root-mean square of the difference of successive intervals (RMSSD). However Bland-Altman analysis showed a large divergence for LF/HF ratio parameter. In addition, children with SDB had depressed SDNN and RMSSD and elevated LF/HF in comparison to children without SDB. In conclusion, PRV provides the accurate estimate of HRV in time domain analysis but does not reflect precise estimation for parameters in frequency domain.

  15. Low-dose or low-dose-rate ionizing radiation-induced bioeffects in animal models.

    Science.gov (United States)

    Tang, Feng Ru; Loke, Weng Keong; Khoo, Boo Cheong

    2017-03-01

    Animal experimental studies indicate that acute or chronic low-dose ionizing radiation (LDIR) (≤100 mSv) or low-dose-rate ionizing radiation (LDRIR) (radiation exposure (i.e. acute, fractionated or chronic radiation exposure), type of radiation, combination of radiation with other toxic agents (such as smoking, pesticides or other chemical toxins) or animal experimental designs. In this review paper, we aimed to update radiation researchers and radiologists on the current progress achieved in understanding the LDIR/LDRIR-induced bionegative and biopositive effects reported in the various animal models. The roles played by a variety of molecules that are implicated in LDIR/LDRIR-induced health effects will be elaborated. The review will help in future investigations of LDIR/LDRIR-induced health effects by providing clues for designing improved animal research models in order to clarify the current controversial/contradictory findings from existing studies. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  16. Injury of the blood-testies barrier after low-dose-rate chronic radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Young Hoon; Bae Min Ji; Lee, Chang Geun; Yang, Kwang Mo; Jur, Kyu; Kim, Jong Sun [Dongnam Institute of Radiological and Medical Science, Busan (Korea, Republic of)

    2014-04-15

    The systemic effect of radiation increases in proportionally with the dose and dose rate. Little is known concerning the relationships between harmful effects and accumulated dose, which is derived from continuous low-dose rate radiation exposure. Recent our studies show that low-dose-rate chronic radiation exposure (3.49 mGy/h) causes adverse effects in the testis at a dose of 2 Gy (6 mGy/h). However, the mechanism of the low-dose-rate 2 Gy irradiation induced testicular injury remains unclear. The present results indicate that low-dose rate chronic radiation might affect the BTB permeability, possibly by decreasing levels of ZO-1, Occludin-1, and NPC-2. Furthermore, our results suggest that there is a risk of male infertility through BTB impairment even with low-dose-rate radiation if exposure is continuous.

  17. Induction of chromosome aberrations is non-linear within the low dose region and depends on dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Oudalova, A.A.; Geras' kin, S.A.; Dikarev, V.G.; Nesterov, Y.B.; Dikareva, N.S

    2002-07-01

    The low dose region was evaluated for meristem cells of spring barley. A study of the cytogenetic damage in the low dose range was carried out to determine the genuine shape of the dose curve. The relationship between the frequency of aberrant cells and the absorbed dose is shown to be non-linear with a site at low doses within which the cytogenetic damage exceeds the control level significantly and does not depend on dose value. Within the tested exposure region, the aberrant cell frequency is found to decrease with increasing dose rate, but the shape of the dose curve remained invariable. The piecewise linear model fits the experimental data much better than the linear one. (author)

  18. Bit rate and pulse width dependence of four-wave mixing of short optical pulses in semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Diez, S.; Mecozzi, A.; Mørk, Jesper

    1999-01-01

    We investigate the saturation properties of four-wave mixing of short optical pulses in a semiconductor optical amplifier. By varying the gain of the optical amplifier, we find a strong dependence of both conversion efficiency and signal-to-background ratio on pulse width and bit rate....... In particular, the signal-to-background ratio can be optimized for a specific amplifier gain. This behavior, which is coherently described in experiment and theory, is attributed to the dynamics of the amplified spontaneous emission, which is the main source of noise in a semiconductor optical amplifier....

  19. KAPTURE-2. A picosecond sampling system for individual THz pulses with high repetition rate

    Science.gov (United States)

    Müller, A.-S.

    2017-01-01

    This paper presents a novel data acquisition system for continuous sampling of ultra-short pulses generated by terahertz (THz) detectors. Karlsruhe Pulse Taking Ultra-fast Readout Electronics (KAPTURE) is able to digitize pulse shapes with a sampling time down to 3 ps and pulse repetition rates up to 500 MHz. KAPTURE has been integrated as a permanent diagnostic device at ANKA and is used for investigating the emitted coherent synchrotron radiation in the THz range. A second version of KAPTURE has been developed to improve the performance and flexibility. The new version offers a better sampling accuracy for a pulse repetition rate up to 2 GHz. The higher data rate produced by the sampling system is processed in real-time by a heterogeneous FPGA and GPU architecture operating up to 6.5 GB/s continuously. Results in accelerator physics will be reported and the new design of KAPTURE be discussed.

  20. Rate equation simulation of temporal characteristics of a pulsed dye laser oscillator

    Indian Academy of Sciences (India)

    S Kundu; K Dasgupta; S Sasikumar; J Singh; A K Ray; S Sinha

    2010-11-01

    A time-dependent, two-dimensional (in space) rate equation model of a transversely-pumped pulsed dye laser oscillator, which incorporates transverse pump intensity variation in the presence of intracavity dye laser radiation, is proposed to under-stand and predict its temporal behaviour. The model yields output pulses which agree well with experimental results using rhodamine 6G and kiton red dyes. The shape, amplitude and temporal position of the simulated pulse within the pump pulse vary dramatically across the tuning range of each dye depending on the relative gain and loss values.

  1. High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier.

    Science.gov (United States)

    Andersen, T V; Schmidt, O; Bruchmann, C; Limpert, J; Aguergaray, C; Cormier, E; Tünnermann, A

    2006-05-29

    We report on the generation of high energy femtosecond pulses at 1 MHz repetition rate from a fiber laser pumped optical parametric amplifier (OPA). Nonlinear bandwidth enhancement in fibers provides the intrinsically synchronized signal for the parametric amplifier. We demonstrate large tunability extending from 700 nm to 1500 nm of femtosecond pulses with pulse energies as high as 1.2 muJ when the OPA is seeded by a supercontinuum generated in a photonic crystal fiber. Broadband amplification over more than 85 nm is achieved at a fixed wavelength. Subsequent compression in a prism sequence resulted in 46 fs pulses. With an average power of 0.5 W these pulses have a peak-power above 10 MW. In particular, the average power and pulse energy scalability of both involved concepts, the fiber laser and the parametric amplifier, will enable easy up-scaling to higher powers.

  2. SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Hansen, J; Bhagwat, M; O’Farrell, D; Damato, A; Friesen, S; Devlin, P; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25

  3. Different dose rate-dependent responses of human melanoma cells and fibroblasts to low dose fast neutrons.

    Science.gov (United States)

    Dionet, Claude; Müller-Barthélémy, Melanie; Marceau, Geoffroy; Denis, Jean-Marc; Averbeck, Dietrich; Gueulette, John; Sapin, Vincent; Pereira, Bruno; Tchirkov, Andrei; Chautard, Emmanuel; Verrelle, Pierre

    2016-09-01

    To analyze the dose rate influence in hyper-radiosensitivity (HRS) of human melanoma cells to very low doses of fast neutrons and to compare to the behaviour of normal human skin fibroblasts. We explored different neutron dose rates as well as possible implication of DNA double-strand breaks (DSB), apoptosis, and energy-provider adenosine-triphosphate (ATP) levels during HRS. HRS in melanoma cells appears only at a very low dose rate (VLDR), while a high dose rate (HDR) induces an initial cell-radioresistance (ICRR). HRS does not seem to be due either to DSB or to apoptosis. Both phenomena (HRS and ICRR) appear to be related to ATP availability for triggering cell repair. Fibroblast survival after neutron irradiation is also dose rate-dependent but without HRS. Melanoma cells or fibroblasts exert their own survival behaviour at very low doses of neutrons, suggesting that in some cases there is a differential between cancer and normal cells radiation responses. Only the survival of fibroblasts at HDR fits the linear no-threshold model. This new insight into human cell responses to very low doses of neutrons, concerns natural radiations, surroundings of accelerators, proton-therapy devices, flights at high altitude. Furthermore, ATP inhibitors could increase HRS during high-linear energy transfer (high-LET) irradiation.

  4. Increasing infection rate in multiple implanted pulse generator changes in movement disorder patients treated with deep brain stimulation

    DEFF Research Database (Denmark)

    Thrane, Jens F; Sunde, Niels A; Bergholt, Bo

    2014-01-01

    Increasing infection rate in multiple implanted pulse generator changes in movement disorder patients treated with deep brain stimulation......Increasing infection rate in multiple implanted pulse generator changes in movement disorder patients treated with deep brain stimulation...

  5. Genetic Factors Affecting Susceptibility to Low Dose & Low Dose-Rate Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, Joel

    2014-04-18

    Our laboratory has, among other things, developed and used the gamma H2AX focus assay and other chromosomal and cell killing assays to show that differences in this DNA double strand break (dsb) related response can be clearly and distinctly demonstrated for cells which are mildly hyper-radiosensitive such as those associated with A-T heterozygosity. We have found this level of mild hypersensitivity for cells from some 20 to 30 % of apparently normal individuals and from apparently normal parents of Retinoblastoma patients. We found significant differences in gene expression in somatic cells from unaffected parents of Rb patients as compared with normal controls, suggesting that these parents may harbor some as yet unidentified genetic abnormality. In other experiments we sought to determine the extent of differences in normal human cellular reaponses to radiation depending on their irradiation in 2D monolayer vs 3D organized acinar growth conditions. We exmined cell reproductive death, chromosomal aberration induction, and the levels of γ-H2AX foci in cells after single acute gamma-ray doses and immediately after 20 hours of irradiation at a dose rate of 0.0017 Gy/min. We found no significant differences in the dose-responses of these cells under the 2D or 3D growth conditions. While this does not mean such differences cannot occur in other situations, it does mean that they do not generally or necessarily occur. In another series of studies in collaboration with Dr Chuan Li, with supprt from this current grant. We reported a role for apoptotic cell death in promoting wound healing and tissue regeneration in mice. Apoptotic cells released growth signals that stimulated the proliferation of progenitor or stem cells. In yet another collaboration with Dr, B. Chen with funds from this grant, the relative radiosensitivity to cell killing as well as chromosomal instability of 13 DNA-PKcs site-directed mutant cell lines (defective at phosphorylation sites or kinase

  6. A simple sub-nanosecond ultraviolet light pulse generator with high repetition rate and peak power.

    Science.gov (United States)

    Binh, P H; Trong, V D; Renucci, P; Marie, X

    2013-08-01

    We present a simple ultraviolet sub-nanosecond pulse generator using commercial ultraviolet light-emitting diodes with peak emission wavelengths of 290 nm, 318 nm, 338 nm, and 405 nm. The generator is based on step recovery diode, short-circuited transmission line, and current-shaping circuit. The narrowest pulses achieved have 630 ps full width at half maximum at repetition rate of 80 MHz. Optical pulse power in the range of several hundreds of microwatts depends on the applied bias voltage. The bias voltage dependences of the output optical pulse width and peak power are analysed and discussed. Compared to commercial UV sub-nanosecond generators, the proposed generator can produce much higher pulse repetition rate and peak power.

  7. Modeling Low-Dose-Rate Effects in Irradiated Bipolar-Base Oxides

    Energy Technology Data Exchange (ETDEWEB)

    Cirba, C.R.; Fleetwood, D.M.; Graves, R.J.; Michez, A.; Milanowski, R.J.; Saigne, F.; Schrimpf, R.D.; Witczak, S.C.

    1998-10-26

    A physical model is developed to quantify the contribution of oxide-trapped charge to enhanced low-dose-rate gain degradation in bipolar junction transistors. Multiple-trapping simulations show that space charge limited transport is partially responsible for low-dose-rate enhancement. At low dose rates, more holes are trapped near the silicon-oxide interface than at high dose rates, resulting in larger midgap voltage shifts at lower dose rates. The additional trapped charge near the interface may cause an exponential increase in excess base current, and a resultant decrease in current gain for some NPN bipolar technologies.

  8. Ion recombination correction factors (P(ion)) for Varian TrueBeam high-dose-rate therapy beams.

    Science.gov (United States)

    Kry, Stephen F; Popple, Richard; Molineu, Andrea; Followill, David S

    2012-11-08

    Ion recombination is approximately corrected for in the Task Group 51 protocol by Pion, which is calculated by a two-voltage measurement. This measurement approach may be a poor estimate of the true recombination, particularly if Pion is large (greater than 1.05). Concern exists that Pion in high-dose-per-pulse beams, such as flattening filter free (FFF) beams, may be unacceptably high, rendering the two-voltage measurement technique inappropriate. Therefore, Pion was measured for flattened beams of 6, 10, 15, and 18 MV and for FFF beams of 6 and 10 MV. The values for the FFF beams were verified with 1/V versus 1/Q curves (Jaffé plots). Pion was also measured for electron beams of 6, 12, 16, 18, and 20 MeV on a traditional accelerator, as well as on the high-dose-rate Varian TrueBeam accelerator. The measurements were made at a range of depths and with PTW, NEL, and Exradin Farmer-type chambers. Consistent with the increased dose per pulse, Pion was higher for FFF beams than for flattening filter beams. However, for all beams, measurement locations, and chambers examined, Pion never exceeded 1.018. Additionally, Pion was always within 0.3% of the recombination calculated from the Jaffé plots. We conclude that ion recombination can be adequately accounted for in high-dose-rate FFF beams using Pion determined with the standard two-voltage technique.

  9. Dose equivalent rate constants and barrier transmission data for nuclear medicine facility dose calculations and shielding design.

    Science.gov (United States)

    Kusano, Maggie; Caldwell, Curtis B

    2014-07-01

    A primary goal of nuclear medicine facility design is to keep public and worker radiation doses As Low As Reasonably Achievable (ALARA). To estimate dose and shielding requirements, one needs to know both the dose equivalent rate constants for soft tissue and barrier transmission factors (TFs) for all radionuclides of interest. Dose equivalent rate constants are most commonly calculated using published air kerma or exposure rate constants, while transmission factors are most commonly calculated using published tenth-value layers (TVLs). Values can be calculated more accurately using the radionuclide's photon emission spectrum and the physical properties of lead, concrete, and/or tissue at these energies. These calculations may be non-trivial due to the polyenergetic nature of the radionuclides used in nuclear medicine. In this paper, the effects of dose equivalent rate constant and transmission factor on nuclear medicine dose and shielding calculations are investigated, and new values based on up-to-date nuclear data and thresholds specific to nuclear medicine are proposed. To facilitate practical use, transmission curves were fitted to the three-parameter Archer equation. Finally, the results of this work were applied to the design of a sample nuclear medicine facility and compared to doses calculated using common methods to investigate the effects of these values on dose estimates and shielding decisions. Dose equivalent rate constants generally agreed well with those derived from the literature with the exception of those from NCRP 124. Depending on the situation, Archer fit TFs could be significantly more accurate than TVL-based TFs. These results were reflected in the sample shielding problem, with unshielded dose estimates agreeing well, with the exception of those based on NCRP 124, and Archer fit TFs providing a more accurate alternative to TVL TFs and a simpler alternative to full spectral-based calculations. The data provided by this paper should assist

  10. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  11. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken; Mitomo, Masanori [Osaka National Hospital (Japan); Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji [Osaka Prefectural Center for Adult Diseases (Japan); Yoshida, Mineo [Sanda City Hospital, Hyogo (Japan)

    2002-12-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients

  12. Sternal Pulse Rate Variability Compared with Heart Rate Variability on Healthy Subjects

    DEFF Research Database (Denmark)

    Chreiteh, Shadi; Belhage, Bo; Hoppe, Karsten

    2014-01-01

    differing more than 50 ms (pNN50) were calculated from the R peak-to-R peak (R-R) and pulse-to-pulse (P-P) intervals. In the frequency domain the low and high frequency ratio of the power spectral density (LF/HF) was also computed. The Pearson correlation coefficient showed significant correlation for all...

  13. Programmable Control of the Pulse Repetition Rate in the Multiwave Strontium Vapor Laser System

    Directory of Open Access Journals (Sweden)

    Soldatov Anatoly

    2016-01-01

    Full Text Available The aim of the present work was the development of laser systems for ablation of biological tissues with a programmable control over the lasing pulse repetition rate in a wide range. A two-stage laser system consisting of a master oscillator and a power amplifier based on strontium vapor laser has been developed. The operation of the laser system in a single-pulse mode operation, multipulse mode operation, and with a pulse repetition rate up to 20 kHz has been technically implemented. The possibility of a bone tissue ablation with no visible thermal damage is shown.

  14. Dose-rate effects for apoptosis and micronucleus formation in gamma-irradiated human lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Boreham, D.R.; Dolling, J.-A.; Maves, S.R. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Siwarungsun, N. [Chulalongkorn Univ., Bangkok (Thailand); Mitchel, R.E.J. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    2000-07-01

    We have compared dose-rate effects for {gamma}-radiation-induced apoptosis and micronucleus formation in human lymphocytes. Long-term assessment of individual radiation-induced apoptosis showed little intraindividual variation but significant interindividual variation. The effectiveness of radiation exposure to cause apoptosis or micronucleus formation was reduced by low-dose-rate exposures, but the reduction was apparent at different dose rates for these two end points. Micronucleus formation showed a dose-rate effect when the dose rate was lowered to 0.29 cGy/min, but there was no accompanying cell cycle delay. A further increase in the dose-rate effect was seen at 0.15 cGy/min, but was now accompanied by cell cycle delay. There was no dose-rate effect for the induction of apoptosis until the dose rate was reduced to 0.15 cGy/min, indicating that the mechanisms or signals for processing radiation-induced lesions for these two end points must be different at least in part. There appear to be two mechanisms that contribute to the dose-rate effect for micronucleus formation. One of these does not affect binucleate cell frequency and occurs at dose rates higher than that required to produce a dose-rate effect for apoptosis, and one affects binucleate cell frequency, induced only at the very low dose rate which coincidentally produces a dose-rate effect for apoptosis. Since the dose rate at which cells showed reduced apoptosis as well as a further reduction in micronucleus formation was very low, we conclude that the processing of the radiation-induced lesions that induce apoptosis, and some micronuclei, is very slow in quiescent and PHA-stimulated lymphocytes, respectively. (author)

  15. Experimental study on port-wine stain treated by small dose HpD and variable pulsed 532nm laser

    Science.gov (United States)

    Qin, Meixiang; Zhu, Jing; Yuan, Xiawen

    2005-07-01

    To obtain a new therapy for port-wine stain (PWS) with good effect and few side effects, the Leghorn chicken combs chosen as the animal models and treated by small dose HpD and variable pulsed 532nm laser were evaluated clinically using four different scoring systems commonly used in previous publication. Result: It was shown significant difference among 5 groups (p<0.01), and the treatment groups have better effect than the control groups. There's also difference among the four treatment groups and the higher dose of HpD has better effect. In all groups the higher the fluency of laser was used, the better the effect produce. Conclusion: The results provide evidence that small dose HpD and variable pulsed 532nm laser can increase the efficacy of treatment in PWS. Increasing the fluency of laser and the dose of HpD can improve the efficacy.

  16. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  17. Low Rate Sampling of Pulse Streams with Application to Ultrasound Imaging

    CERN Document Server

    Tur, Ronen; Friedman, Zvi

    2010-01-01

    Signals comprised of a stream of short pulses appear in many applications including bio-imaging, radar, and ultrawideband communication. Recently, a new framework, referred to as finite rate of innovation, has paved the way to low rate sampling of such pulses by exploiting the fact that only a small number of parameters per unit time are needed to fully describe these signals. Unfortunately, for high rates of innovation, existing approaches are numerically unstable. In this paper we propose a general sampling approach which leads to stable recovery even in the presence of many pulses. We begin by deriving a condition on the sampling kernel which allows perfect reconstruction of periodic streams of pulses from a minimal number of samples. This extends previous work which assumes that the sampling kernel is an ideal low-pass filter. A compactly supported class of filters, satisfying the mathematical condition, is then introduced, leading to a sampling framework based on compactly supported kernels. We then exte...

  18. Possible use of EPDM in radioactive waste disposal: Long term low dose rate and short term high dose rate irradiation in aquatic and atmospheric environment

    Science.gov (United States)

    Hacıoğlu, Fırat; Özdemir, Tonguç; Çavdar, Seda; Usanmaz, Ali

    2013-02-01

    In this study, changes in the properties of ethylene propylene diene terpolymer (EPDM) irradiated with different dose rates in ambient atmosphere and aqueous environment were investigated. Irradiations were carried out both with low dose and high dose rate irradiation sources. EPDM samples which were differentiated from each other by peroxide type and 5-ethylidene 2-norbornene (ENB) contents were used. Long term low dose rate irradiations were carried out for the duration of up to 2.5 years (total dose of 1178 kGy) in two different irradiation environments. Dose rates (both high and low), irradiation environments (in aquatic and open to atmosphere), and peroxide types (aliphatic or aromatic) were the parameters studied. Characterization of irradiated EPDM samples were performed by hardness, compression, tensile, dynamic mechanical analysis (DMA), TGA-FTIR, ATR-FTIR, XRD and SEM tests. It was observed that the irradiation in water environment led to a lower degree of degradation when compared to that of irradiation open to atmosphere for the same irradiation dose. In addition, irradiation environment, peroxide type and dose rate had effects on the extent of change in the properties of EPDM. It was observed that EPDM is relatively radiation resistant and a candidate polymer for usage in radioactive waste management.

  19. Increased repair of {gamma}-induced DNA double-strand breaks at lower dose-rate in CHO cells

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, D.; Hindo, J.; Averbeck, D. [Centre Universitaire d' Orsay, Inst. Curie-Section de Recherche, Orsay CEDEX (France)]. E-mail: dietrich.averbeck@curie.u-psud.fr

    2004-02-01

    DNA double-strand breaks (DSBs) are highly cell damaging. We asked whether for a given dose a longer irradiation time would be advantageous for the repair of DSBs. Varying the {gamma}-irradiation dose and its delivery time (0.05 Gy/min low dose-rate (LDR) compared with 3.5 Gy/min high dose-rate), confluent Chinese hamster ovary cells (CHO-K1) and Ku80 mutant cells (xrs-6) deficient in nonhomologous end-joining (NHEJ) were irradiated in agarose plugs at room temperature using a cesium-137 {gamma}-ray source. We used pulsed-field gel electrophoresis (PFGE) to measure DSBs in terms of the fraction of activity released (FAR). At LDR, one third of DSBs were repaired in CHO-K1 but not in xrs-6 cells, indicating the involvement of NHEJ in the repair of {gamma}-induced DSBs at a prolonged irradiation incubation time. To improve DSB measurements, we introduced in our PFGE protocol an antioxidant at the cell lysis step, thus avoiding free-radical side reactions on DNA and spurious DSBs. Addition of the metal chelator deferoxamine (DFO) decreased more efficiently the basal DSB level than did reduced glutathione (GSH), showing that measuring DSBs in the absence of DFO reduces precision and underestimates the role of NHEJ in the dose-rate effect on DSB yield. (author)

  20. Dose rate effects on the thermoluminescence kinetics properties of MWCVD diamond films

    Energy Technology Data Exchange (ETDEWEB)

    Gastelum, S.; Chernov, V.; Melendrez, R.; Soto-Puebla, D.; Pedroza-Montero, M.; Barboza-Flores, M. [Centro de Investigacion en Fisica, Universidad de Sonora, AP 5-088 Hermosillo, Sonora 83190 (Mexico); Cruz-Zaragoza, E. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, AP 70-543 Mexico D.F. (Mexico); Favalli, A. [European Commission, Joint Research Centre, Institute for the Protection and the Security of the Citizen, TP800,Via E. Fermi, 21020 Ispra (Italy)

    2007-09-15

    Dose rate effects are important in thermoluminescent (TL) dosimeter applications because a certain absorbed dose given at different dose rates may result in a different TL yield. The present work reports about the dose rate effects on TL glow curves and kinetics properties of microwave plasma assisted chemical vapor deposition (MWCVD) diamond films grown on (100) silicon. The diamond films were exposed to {gamma} radiation at 20.67, 43.4 and 81.11 Gy min{sup -1} dose rates in the range of 0.05-10 kGy. The films showed a linear dose behavior up to 2 kGy and reached saturation for higher doses. The TL intensity varied as a function of dose rate and the samples had a maximum TL response for relatively lower dose rates. A single first order kinetics TL peak was typical for low doses while at higher doses two first order kinetics peaks were necessary to fit the glow curves. The results indicate that dose rate effects may be significant in dosimetric applications of MWCVD diamond. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. A new method of measuring a large pulsed neutron fluence or dose exploiting the die-away of thermalized neutrons in a polyethylene moderator

    Science.gov (United States)

    Leake, J. W.; Lowe, T.; Mason, R. S.; White, G.

    2010-01-01

    Computer simulations of the response to very short pulses of neutron and gamma radiation of a spherical polyethylene moderator with a central thermal neutron counter and a new, fast, active restore amplifier system have been carried out. A large neutron burst produces count rates in the detector that are too high to measure initially but when the exponential decay of the count rate falls below about 50 k per sec then counting can start. If the counts are recorded in contiguous time intervals (of 60 μs in this case) and the time is measured at which the measured count in an interval falls to 1 or 2 then the size of the initial burst can be calculated. It is shown that it should be possible to measure pulsed neutron ambient dose equivalent H*(10) or dose equivalent rate from about 2 nSv up to about 100 μSv per burst, or 7.2 N μSv s h -1 to 360 N mSv s h -1, where N is the number of neutron bursts per second. The calculations show that a gamma burst of about 10 μGy can be tolerated without affecting the measurement of the largest neutron bursts. This extends our earlier estimate of the maximum dose that can be measured for pulsed neutrons by more than 10 k. This method could also be used to measure the neutron fluence or dose from a single unplanned event such as a beam dump on an accelerator or a criticality incident from fissile material. Although the method described is new it is based on a combination of proven techniques.

  2. Chromosome aberrations in human lymphocytes induced by 250 MeV protons: effects of dose, dose rate and shielding

    Science.gov (United States)

    George, K.; Willingham, V.; Wu, H.; Gridley, D.; Nelson, G.; Cucinotta, F. A.

    2002-01-01

    Although the space radiation environment consists predominantly of energetic protons, astronauts inside a spacecraft are chronically exposed to both primary particles as well as secondary particles that are generated when the primary particles penetrate the spacecraft shielding. Secondary neutrons and secondary charged particles can have an LET value that is greater than the primary protons and, therefore, produce a higher relative biological effectiveness (RBE). Using the accelerator facility at Loma Linda University, we exposed human lymphocytes in vitro to 250 MeV protons with doses ranging from 0 to 60 cGy at three different dose rates: a low dose rate of 7.5 cGy/h, an intermediate dose rate of 30 cGy/h and a high dose rate of 70 cGy/min. The effect of 15 g/cm2 aluminum shielding on the induction of chromosome aberrations was investigated for each dose rate. After exposure, lymphocytes were incubated in growth medium containing phytohemagglutinin (PHA) and chromosome spreads were collected using a chemical-induced premature chromosome condensation (PCC) technique. Aberrations were analyzed using the fluorescence in situ hybridization (FISH) technique with three different colored chromosome-painting probes. The frequency of reciprocal and complex-type chromosome exchanges were compared in shielded and unshielded samples. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

  3. Respiratory rate derived from smartphone-camera-acquired pulse photoplethysmographic signals.

    Science.gov (United States)

    Lázaro, Jesús; Nam, Yunyoung; Gil, Eduardo; Laguna, Pablo; Chon, Ki H

    2015-11-01

    A method for deriving respiratory rate from smartphone-camera-acquired pulse photoplethysmographic (SCPPG) signal is presented. Our method exploits respiratory information by examining the pulse wave velocity and dispersion from the SCPPG waveform and we term these indices as the pulse width variability (PWV). A method to combine information from several derived respiration signals is also presented and it is used to combine PWV information with other methods such as pulse amplitude variability (PAV), pulse rate variability (PRV), and respiration-induced amplitude and frequency modulations (AM and FM) in SCPPG signals.Evaluation is performed on a database containing SCPPG signals recorded from 30 subjects during controlled respiration experiments at rates from 0.2 to 0.6 Hz with an increment of 0.1 Hz, using three different devices: iPhone 4S, iPod 5, and HTC One M8. Results suggest that spontaneous respiratory rates (0.2-0.4 Hz) can be estimated from SCPPG signals by the PWV- and PRV-based methods with low relative error (median of order 0.5% and interquartile range of order 2.5%). The accuracy can be improved by combining PWV and PRV with other methods such as PAV, AM and/or FM methods. Combination of these methods yielded low relative error for normal respiratory rates, and maintained good performance at higher rates (0.5-0.6 Hz) when using the iPhone 4S or iPod 5 devices.

  4. Temporal dynamics of high repetition rate pulsed single longitudinal mode dye laser

    Indian Academy of Sciences (India)

    G Sridhar; V S Rawar; S Singh; L M Gantayet

    2013-08-01

    Theoretical and experimental studies of temporal dynamics of grazing incidence grating (GIG) cavity, single-mode dye laser pumped by high repetition rate copper vapour laser (CVL) are presented. Spectral chirp of the dye laser as they evolve in the cavity due to transient phase dynamics of the amplifier gain medium is studied. Effect of grating efficiency, focal spot size, pump power and other cavity parameters on the temporal behaviour of narrow band dye laser such as build-up time, pulse shape and pulse width is studied using the four level dye laser rate equation and photon evolution equation. These results are compared with experimental observations of GIG single-mode dye laser cavity. The effect of pulse stretching of CVL pump pulse on the temporal dynamics of the dye laser is studied.

  5. Adjustable high-repetition-rate pulse trains in a passively-mode-locked fiber laser

    Science.gov (United States)

    Si Fodil, Rachid; Amrani, Foued; Yang, Changxi; Kellou, Abdelhamid; Grelu, Ph.

    2016-07-01

    We experimentally investigate multipulse regimes obtained within a passively-mode-locked fiber laser that includes a Mach-Zehnder (MZ) interferometer. By adjusting the time delay imbalance of the MZ, ultrashort pulse trains at multi-GHz repetition rates are generated. We compare the observed dynamics with high-harmonic mode locking, and show that the multi-GHz pulse trains display an inherent instability, which has been overlooked. By using a recirculation loop containing the MZ, we demonstrate a significant improvement of the pulse train stability.

  6. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kinhikar, Rajesh A [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sharma, Pramod K [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Tambe, Chandrashekhar M [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Mahantshetty, Umesh M [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sarin, Rajiv [Advanced Centre for Training Research and Education in Cancer, Kharghar, Navi Mumbai (India); Deshpande, Deepak D [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Shrivastava, Shyam K [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India)

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  7. Generation of picosecond laser pulses at 1030 nm with gigahertz range continuously tunable repetition rate.

    Science.gov (United States)

    Aubourg, Adrien; Lhermite, Jérôme; Hocquet, Steve; Cormier, Eric; Santarelli, Giorgio

    2015-12-01

    We report on a watt range laser system generating picosecond pulses using electro-optical modulation of a 1030 nm single frequency low noise laser diode. Its repetition rate is continuously tunable between 11 and 18 GHz. Over this range, output spectra and pulse characteristics are measured and compared with a numerical simulation. Finally, amplitude and residual phase noise measurements of the source are also presented.

  8. Wrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology

    Directory of Open Access Journals (Sweden)

    Fu-Kang Wang

    2016-10-01

    Full Text Available To achieve sensitivity, comfort, and durability in vital sign monitoring, this study explores the use of radar technologies in wearable devices. The study first detected the respiratory rates and heart rates of a subject at a one-meter distance using a self-injection-locked (SIL radar and a conventional continuous-wave (CW radar to compare the sensitivity versus power consumption between the two radars. Then, a pulse rate monitor was constructed based on a bistatic SIL radar architecture. This monitor uses an active antenna that is composed of a SIL oscillator (SILO and a patch antenna. When attached to a band worn on the subject’s wrist, the active antenna can monitor the pulse on the subject’s wrist by modulating the SILO with the associated Doppler signal. Subsequently, the SILO’s output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information.

  9. Hydrodynamic size distribution of gold nanoparticles controlled by repetition rate during pulsed laser ablation in water

    Science.gov (United States)

    Menéndez-Manjón, Ana; Barcikowski, Stephan

    2011-02-01

    Most investigations on the laser generation and fragmentation of nanoparticles focus on Feret particle size, although the hydrodynamic size of nanoparticles is of great importance, for example in biotechnology for diffusion in living cells, or in engineering, for a tuned rheology of suspensions. In this sense, the formation and fragmentation of gold colloidal nanoparticles using femtosecond laser ablation at variable pulse repetition rates (100-5000 Hz) in deionized water were investigated through their plasmon resonance and hydrodynamic diameter, measured by Dynamic Light Scattering. The increment of the repetition rate does not influence the ablation efficiency, but produces a decrease of the hydrodynamic diameter and blue-shift of the plasmon resonance of the generated gold nanoparticles. Fragmentation, induced by inter-pulse irradiation of the colloids was measured online, showing to be more effective low repetition rates. The pulse repetition rate is shown to be an appropriate laser parameter for hydrodynamic size control of nanoparticles without further influence on the production efficiency.

  10. Wrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology.

    Science.gov (United States)

    Wang, Fu-Kang; Tang, Mu-Cyun; Su, Sheng-Chao; Horng, Tzyy-Sheng

    2016-10-26

    To achieve sensitivity, comfort, and durability in vital sign monitoring, this study explores the use of radar technologies in wearable devices. The study first detected the respiratory rates and heart rates of a subject at a one-meter distance using a self-injection-locked (SIL) radar and a conventional continuous-wave (CW) radar to compare the sensitivity versus power consumption between the two radars. Then, a pulse rate monitor was constructed based on a bistatic SIL radar architecture. This monitor uses an active antenna that is composed of a SIL oscillator (SILO) and a patch antenna. When attached to a band worn on the subject's wrist, the active antenna can monitor the pulse on the subject's wrist by modulating the SILO with the associated Doppler signal. Subsequently, the SILO's output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information.

  11. Feasibility of constant dose rate VMAT in the treatment of nasopharyngeal cancer patients

    OpenAIRE

    Yu, Wenliang; Shang, Haijiao; Xie, Congying; Han, CE; Yi, Jinling; Zhou, Yongqiang; Jin, Xiance

    2014-01-01

    Purpose To investigate the feasibility of constant dose rate volumetric modulated arc therapy (CDR-VMAT) in the treatment of nasopharyngeal cancer (NPC) patients and to introduce rotational arc radiotherapy for linacs incapable of dose rate variation. Materials and methods Twelve NPC patients with various stages treated previously using variable dose rate (VDR) VMAT were enrolled in this study. CDR-VMAT, VDR-VMAT and mutlicriteria optimization (MCO) VMAT plans were generated for each patient ...

  12. The dose and dose-rate effects of paternal irradiation on transgenerational instability in mice: a radiotherapy connection.

    Directory of Open Access Journals (Sweden)

    Safeer K Mughal

    Full Text Available The non-targeted effects of human exposure to ionising radiation, including transgenerational instability manifesting in the children of irradiated parents, remains poorly understood. Employing a mouse model, we have analysed whether low-dose acute or low-dose-rate chronic paternal γ-irradiation can destabilise the genomes of their first-generation offspring. Using single-molecule PCR, the frequency of mutation at the mouse expanded simple tandem repeat (ESTR locus Ms6-hm was established in DNA samples extracted from sperm of directly exposed BALB/c male mice, as well as from sperm and the brain of their first-generation offspring. For acute γ-irradiation from 10-100 cGy a linear dose-response for ESTR mutation induction was found in the germ line of directly exposed mice, with a doubling dose of 57 cGy. The mutagenicity of acute exposure to 100 cGy was more pronounced than that for chronic low-dose-rate irradiation. The analysis of transgenerational effects of paternal irradiation revealed that ESTR mutation frequencies were equally elevated in the germ line (sperm and brain of the offspring of fathers exposed to 50 and 100 cGy of acute γ-rays. In contrast, neither paternal acute irradiation at lower doses (10-25 cGy, nor low-dose-rate exposure to 100 cGy affected stability of their offspring. Our data imply that the manifestation of transgenerational instability is triggered by a threshold dose of acute paternal irradiation. The results of our study also suggest that most doses of human exposure to ionising radiation, including radiotherapy regimens, may be unlikely to result in transgenerational instability in the offspring children of irradiated fathers.

  13. Using Pulse Rate in Estimating Workload Evaluating a Load Mobilizing Activity

    Directory of Open Access Journals (Sweden)

    Juan Alberto Castillo

    2014-06-01

    Full Text Available Introduction: The pulse rate is a direct indicator of the state of the cardiovascular system, in ad-dition to being an indirect indicator of the energy expended in performing a task. The pulse of a person is the number of pulses recorded in a peripheral artery per unit time; the pulse appears as a pressure wave moving along the blood vessels, which are flexible, “in large arterial branches, speed of 7-10 m/s in the small arteries, 15 to 35 m/s”. Materials and methods: The aim of this study was to assess heart rate, using the technique of recording the frequency of the pulse, oxy-gen consumption and observation of work activity in the estimation of the workload in a load handling task for three situations: lift/transfer/deposit; before, during and after the task the pulse rate is recorded for 24 young volunteers (10 women and 14 men under laboratory conditions. We performed a gesture analysis of work activity and lifting and handling strategies. Results: We observed an increase between initial and final fp in both groups and for the two tasks, a dif¬ference is also recorded in the increase in heart rate of 17.5 for charging 75 % of the participants experienced an increase in fp above 100 lat./min. Par 25 kg, registered values indicate greater than 114 lat./min and 17.5 kg than 128 lat./min values. Discussion: The pulse rate method is recommended for its simplicity of use for operational staff, supervisors and managers and indus¬trial engineers not trained in the physiology method can also be used by industrial hygienists.

  14. Vitamin D production depends on ultraviolet-B dose but not on dose rate: a randomized controlled trial

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A

    2011-01-01

    Ultraviolet-B (UV-B) radiation increases serum vitamin D level expressed as 25-hydroxyvitamin D(3) (25(OH)D), but the dose-response relationship and the importance of dose rate is unclear. Of 172 fair-skinned persons screened for 25(OH)D, 55 with insufficient baseline 25(OH)D=50 nm (mean 31.2 nm......-B treatments of 3 SED with 24.8 nm on average and 14.2 nm after four UV-B treatments of just 0.375 SED. In conclusion, the increase in 25(OH)D after UV-B exposure depends on the dose but not on the dose rate (1-20 min). Further, a significant increase in 25(OH)D was achieved with a very low UV-B dose.......) were selected and randomized to one of 11 groups of five participants. Each group was exposed to one of four different UV-B doses: 0.375, 0.75, 1.5 or 3.0 standard erythema dose (SED) for 1, 5, 10 or 20 min. All participants had four UV-B sessions with 2- to 3-day interval with 24% of their skin...

  15. ``In vivo'' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

    Science.gov (United States)

    Mejía, C. A. Reynoso; Burgos, A. E. Buenfil; Trejo, C. Ruiz; García, A. Mota; Durán, E. Trejo; Ponce, M. Rodríguez; de Buen, I. Gamboa

    2010-12-01

    The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured "in vivo" by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the "in vivo" measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the "in vivo" dose is fully described.

  16. Absorbed dose rate in air in metropolitan Tokyo before the Fukushima Daiichi Nuclear Power Plant accident.

    Science.gov (United States)

    Inoue, K; Hosoda, M; Fukushi, M; Furukawa, M; Tokonami, S

    2015-11-01

    The monitoring of absorbed dose rate in air has been carried out continually at various locations in metropolitan Tokyo after the accident of the Fukushima Daiichi Nuclear Power Plant. While the data obtained before the accident are needed to more accurately assess the effects of radionuclide contamination from the accident, detailed data for metropolitan Tokyo obtained before the accident have not been reported. A car-borne survey of the absorbed dose rate in air in metropolitan Tokyo was carried out during August to September 2003. The average absorbed dose rate in air in metropolitan Tokyo was 49±6 nGy h(-1). The absorbed dose rate in air in western Tokyo was higher compared with that in central Tokyo. Here, if the absorbed dose rate indoors in Tokyo is equivalent to that outdoors, the annual effective dose would be calculated as 0.32 mSv y(-1).

  17. ``In Vivo'' Dosimetry in High Dose Rate Brachytherapy for Cervical Cancer Treatments

    Science.gov (United States)

    González-Azcorra, S. A.; Mota-García, A.; Poitevín-Chacón, M. A.; Santamaría-Torruco, B. J.; Rodríguez-Ponce, M.; Herrera-Martínez, F. P.; Gamboa de Buen, I.; Ruíz-Trejo, C.; Buenfil, A. E.

    2008-08-01

    In this prospective study, rectal dose was measured "in vivo" using TLD-100 crystals (3×3×1 mm3), and it has been compared to the prescribed dose. Measurements were performed in patients with cervical cancer classified in FIGO stages IB-IIIB and treated with high dose rate brachytherapy (HDR BT) at the Instituto Nacional de Cancerología (INCan).

  18. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    Science.gov (United States)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B. L.; Guha, Sujoy K.

    2010-05-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG ® (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG ®. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  19. Effect of gamma-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    Energy Technology Data Exchange (ETDEWEB)

    Jha, Pradeep K. [School of Medical Science and Technology, Indian Institute of Technology, Kharagpur 721302 (India); Department of Management Science, U.P. Technical University, Lucknow 226021 (India); Jha, Rakhi [School of Medical Science and Technology, Indian Institute of Technology, Kharagpur 721302 (India); Toxicology Laboratory, Department of Zoology, Ch. C.S. University, Meerut 200005 (India); Gupta, B.L. [CH3/56 Kendriya Vihar, Kharghar, Sector-11, Navi Mumbai-410 210 (India); Guha, Sujoy K., E-mail: guha_sk@yahoo.co [School of Medical Science and Technology, Indian Institute of Technology, Kharagpur 721302 (India)

    2010-05-15

    Functional necessity to use a particular range of dose rate and total dose of gamma-initiated polymerization to manufacture a novel polymeric hydrogel RISUG (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG. The results of randomized experiment indicated that a range of 18-24 Gy/min gamma-dose rate and 2.0-2.4 kGy gamma-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  20. Life span of C57 mice as influenced by radiation dose, dose rate, and age at exposure

    Energy Technology Data Exchange (ETDEWEB)

    Spalding, J.F.; Thomas, R.G.; Tietjen, G.L.

    1982-10-01

    This study was designed to measure the life shortening of C57BL/6J male mice as a result of exposure to five external doses from /sup 60/Co gamma radiation delivered at six different dose rates. Total doses ranged from 20 to 1620 rad at exposure rates ranging from 0.7 to 36,000 R/day. The ages of the mice at exposure were newborn, 2, 6, or 15 months. Two replications were completed. Although death was the primary endpoint, we did perform gross necropsies. The life span findings are variable, but we found no consistent shortening compared to control life spans. Therefore, we cannot logically extrapolate life shortening to lower doses, from the data we have obtained. In general, the younger the animals were at the beginning of exposure, the longer their life spans were compared to those of controls. This relationship weakened at the higher doses and dose rates, as mice in these categories tended not to have significantly different life spans from controls. Using life span as a criterion, we find this study suggests that some threshold dosage may exist beyond which effects of external irradiation may be manifested. Up to this threshold, there is no shortening effect on life span compared to that of control mice. Our results are in general agreement with the results of other researchers investigating human and other animal life span effects on irradiation.

  1. Dehydration stress associated variations in rectal temperature, pulse and respiration rate of Marwari sheep

    Directory of Open Access Journals (Sweden)

    Saini, B. S.

    2013-04-01

    Full Text Available The present investigation was carried out in adult female Marwari sheep to evaluate the dehydration stress associated variations in rectal temperature, pulse and respiration rate. The whole experiment was divided into control, thirst and drinking periods. The thirst period was of 5 days to find out the dehydration stress. The control mean values of rectal temperature (oF, pulse rate (min -1 and respiration rate (min -1 were 101.1 ± 0.198, 65.667 ± 2.028 and 25.167 ± 1.515 in the morning and 101.567 ± 0.174, 71.333 ± 1.229 and 27.833 ± 1.83 in the evening, respectively. With the advancement of thirst period the mean values of rectal temperature and pulse rate gradually increased while that of respiration rate increased first and then decreased. After drinking the mean values gradually decreased and on hour 72 of drinking, they differed non significantly (P>0.05 from their respective control values. Changes in rectal temperature, pulse rate and respiration rate indicated the adaptability of the animals to increased thirst periods.Dehydration due to thirst period provoked physiological mechanisms in the body in a manner that helped the animals to survive. Although dehydration was a stress to the animals, but the changes brought about by five days of dehydration were reversible.

  2. Dose-rate conversion factors for external exposure to photons and electrons

    Energy Technology Data Exchange (ETDEWEB)

    Kocher, D.C.

    1981-08-01

    Dose-rate conversion factors for external exposure to photons and electrons have been calculated for approximately 500 radionuclides of potential importance in environmental radiological assessments. The dose-rate factors were obtained using the DOSFACTER computer code. The results given in this report incorporate calculation of electron dose-rate factors for radiosensitive tissues of the skin, improved estimates of organ dose-rate factors for photons, based on organ doses for monoenergetic sources at the body surface of an exposed individual, and the spectra of scattered photons in air from monoenergetic sources in an infinite, uniformly contaminated atmospheric cloud, calculation of dose-rate factors for other radionuclides in addition to those of interest in the nuclear fuel cycle, and incorporation of updated radioactive decay data for all radionuclides. Dose-rate factors are calculated for three exposure modes - immersion in contaminated air, immersion in contaminated water, and exposure at a height of 1 m above a contaminated ground surface. The report presents the equations used to calculate the external dose-rate factors for photons and electrons, documentation of the revised DOSFACTER computer code, and a complete tabulation of the calculated dose-rate factors. 30 refs., 12 figs.

  3. Smartphone-enabled pulse rate variability: an alternative methodology for the collection of heart rate variability in psychophysiological research.

    Science.gov (United States)

    Heathers, James A J

    2013-09-01

    Heart rate variability (HRV) is widely used to assess autonomic nervous system (ANS) function. It is traditionally collected from a dedicated laboratory electrocardiograph (ECG). This presents a barrier to collecting the large samples necessary to maintain the statistical power of between-subject psychophysiological comparisons. An alternative to ECG involves an optical pulse sensor or photoplethysmograph run from a smartphone or similar portable device: smartphone pulse rate variability (SPRV). Experiment 1 determined the simultaneous accuracy between ECG and SPRV systems in n = 10 participants at rest. Raw SPRV values showed a consistent positive bias, which was successfully attenuated with correction. Experiment 2 tested an additional n = 10 participants at rest, during attentional load, and during mild stress (exercise). Accuracy was maintained, but slightly attenuated during exercise. The best correction method maintained an accuracy of +/-2% for low-frequency spectral power, and +/-5% for high-frequency spectral power over all points. Thus, the SPRV system records a pulse-to-pulse approximation of an ECG-derived heart rate series that is sufficiently accurate to perform time- and frequency-domain analysis of its variability, as well as accurately reflecting change in autonomic output provided by typical psychophysiological stimuli. This represents a novel method by which an accurate approximation of HRV may be collected for large-sample or naturalistic cardiac psychophysiological research.

  4. High energy high rate pulsed power processing of materials by powder consolidation and by railgun deposition

    Science.gov (United States)

    Persad, C.; Marcus, H. L.; Weldon, W. F.

    1987-03-01

    This exploratory research program was initiated to investigate the potential of using pulse power sources for powder consolidation, deposition and other High Energy High Rate Processing. The characteristics of the High Energy High Rate (1MJ/s) powder consolidation using megampere current pulses from a Homopolar Generator, have been defined. Molybdenum Alloy TZM, A Nickel based metallic glass, Copper graphite composites, and P/M Aluminum Alloy X7091 have been investigated. The powder consolidation process produced high densification rates. Density values of 80% to 99% could be obtained with sub second high temperature exposure. Specific energy input and applied pressure were controlling process parameters. Time Temperature Transformation (TTT) concepts underpin a fundamental understanding of pulsed power processing. Deposition experiments were conducted using an exploding foil device (EFD) providing an armature feed to railgun mounted in a vacuum chamber. The material to be deposited - in plasma, gas, liquid or solid state - was accelerated electromagnetically in the railgun and deposited on a substrate.

  5. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  6. Use of virtual reality to estimate radiation dose rates in nuclear plants

    Energy Technology Data Exchange (ETDEWEB)

    Augusto, Silas C.; Mol, Antonio C.A.; Jorge, Carlos A.F. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mail: silas@ien.gov.br; Couto, Pedro M. [Faculdade Paraiso, Sao Goncalo, RJ (Brazil). Sistemas de Informacao]. E-mail: pedro98@gmail.com; Cunha, Gerson G.; Landau, Luis [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. de Metodos Computacionais em Engenharia (LAMCE)]. E-mail: gerson@lamce.ufrj.br

    2007-07-01

    Operators in nuclear plants receive radiation doses during several different operation procedures. A training program capable of simulating these operation scenarios will be useful in several ways, helping the planning of operational procedures so as to reduce the doses received by workers, and to minimize operations' times. It can provide safe virtual operation training, visualization of radiation dose rates, and estimation of doses received by workers. Thus, a virtual reality application, a free game engine, has been adapted to achieve the goals of this project. Simulation results for Argonauta research reactor of Instituto de Engenharia Nuclear are shown in this paper. A database of dose rate measurements, previously performed by the radiological protection service, has been used to display the dose rate distribution in the region of interest. The application enables the user to walk in the virtual scenario, displaying at all times the dose accumulated by the avatar. (author)

  7. Inverse modelling of radionuclide release rates using gamma dose rate observations

    Science.gov (United States)

    Hamburger, Thomas; Evangeliou, Nikolaos; Stohl, Andreas; von Haustein, Christoph; Thummerer, Severin; Wallner, Christian

    2015-04-01

    Severe accidents in nuclear power plants such as the historical accident in Chernobyl 1986 or the more recent disaster in the Fukushima Dai-ichi nuclear power plant in 2011 have drastic impacts on the population and environment. Observations and dispersion modelling of the released radionuclides help to assess the regional impact of such nuclear accidents. Modelling the increase of regional radionuclide activity concentrations, which results from nuclear accidents, underlies a multiplicity of uncertainties. One of the most significant uncertainties is the estimation of the source term. That is, the time dependent quantification of the released spectrum of radionuclides during the course of the nuclear accident. The quantification of the source term may either remain uncertain (e.g. Chernobyl, Devell et al., 1995) or rely on estimates given by the operators of the nuclear power plant. Precise measurements are mostly missing due to practical limitations during the accident. The release rates of radionuclides at the accident site can be estimated using inverse modelling (Davoine and Bocquet, 2007). The accuracy of the method depends amongst others on the availability, reliability and the resolution in time and space of the used observations. Radionuclide activity concentrations are observed on a relatively sparse grid and the temporal resolution of available data may be low within the order of hours or a day. Gamma dose rates, on the other hand, are observed routinely on a much denser grid and higher temporal resolution and provide therefore a wider basis for inverse modelling (Saunier et al., 2013). We present a new inversion approach, which combines an atmospheric dispersion model and observations of radionuclide activity concentrations and gamma dose rates to obtain the source term of radionuclides. We use the Lagrangian particle dispersion model FLEXPART (Stohl et al., 1998; Stohl et al., 2005) to model the atmospheric transport of the released radionuclides. The

  8. Characterizing low dose and dose rate effects in rodent and human neural stem cells exposed to proton and gamma irradiation

    Directory of Open Access Journals (Sweden)

    Bertrand P. Tseng

    2013-01-01

    Full Text Available Past work has shown that exposure to gamma rays and protons elicit a persistent oxidative stress in rodent and human neural stem cells (hNSCs. We have now adapted these studies to more realistic exposure scenarios in space, using lower doses and dose rates of these radiation modalities, to further elucidate the role of radiation-induced oxidative stress in these cells. Rodent neural stem and precursor cells grown as neurospheres and human neural stem cells grown as monolayers were subjected to acute and multi-dosing paradigms at differing dose rates and analyzed for changes in reactive oxygen species (ROS, reactive nitrogen species (RNS, nitric oxide and superoxide for 2 days after irradiation. While acute exposures led to significant changes in both cell types, hNSCs in particular, exhibited marked and significant elevations in radiation-induced oxidative stress. Elevated oxidative stress was more significant in hNSCs as opposed to their rodent counterparts, and hNSCs were significantly more sensitive to low dose exposures in terms of survival. Combinations of protons and γ-rays delivered as lower priming or higher challenge doses elicited radioadaptive changes that were associated with improved survival, but in general, only under conditions where the levels of reactive species were suppressed compared to cells irradiated acutely. Protective radioadaptive effects on survival were eliminated in the presence of the antioxidant N-acetylcysteine, suggesting further that radiation-induced oxidative stress could activate pro-survival signaling pathways that were sensitive to redox state. Data corroborates much of our past work and shows that low dose and dose rate exposures elicit significant changes in oxidative stress that have functional consequences on survival.

  9. High-q microring resonator with narrow free spectral range for pulse repetition rate multiplication

    DEFF Research Database (Denmark)

    Pu, Minhao; Ji, Hua; Frandsen, Lars Hagedorn

    2009-01-01

    We demonstrate a silicon-on-insulator microring resonator with a free-spectral-range of 0.32 nm, an extinction ratio of 27 dB, and a quality factor of ~140900 at 1550 nm that is used for pulse repetition-rate multiplication from 10 to 40 GHz.......We demonstrate a silicon-on-insulator microring resonator with a free-spectral-range of 0.32 nm, an extinction ratio of 27 dB, and a quality factor of ~140900 at 1550 nm that is used for pulse repetition-rate multiplication from 10 to 40 GHz....

  10. Energy spectrum measurement and dose rate estimation of natural neutrons in Tibet region

    Institute of Scientific and Technical Information of China (English)

    吴建华; 徐勇军; 刘森林; 汪传高

    2015-01-01

    In this work, natural neutron spectra at nine sites in Tibet region were measured using a multi-sphere neutron spectrometer. The altitude-dependence of the spectra total fluence rate and ambient dose equivalent rate were analyzed. From the normalized natural neutron spectra at different altitudes, the spectrum fractions for neutrons of greater than 0.1 MeV do not differ obviously, while those of the thermal neutrons differ greatly from each other. The total fluence rate, effective dose rate and the ambient dose equivalent rate varied with the altitude according to an exponential law.

  11. Enhanced charge trapping in bipolar spacer oxides during low-dose-rate irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fleetwood, D.M.; Reber, R.A. Jr.; Winokur, P.S. [Sandia National Labs., Albuquerque, NM (United States); Kosier, S.L.; Schrimpf, R.D. [Arizona Univ., Tucson, AZ (United States). Dept. of Electrical and Computer Engineering; Nowlin, R.N. [Air Force Phillips Laboratory, Albuquerque, NM (United States); Pease, R.L. [RLP Research, Inc., Albuquerque, NM (United States); DeLaus, M. [Analog Devices, Wilmington, MA (United States)

    1994-03-01

    Thermally-stimulated-current and capacitance-voltage measurements reveal enhanced hole trapping in bipolar spacer-oxide capacitors irradiated at 0 V at low dose rates. Possible mechanisms and implications for bipolar low-rate response are discussed.

  12. Characterization of pulse amplitude and pulse rate modulation for a human vestibular implant during acute electrical stimulation

    Science.gov (United States)

    Nguyen, T. A. K.; DiGiovanna, J.; Cavuscens, S.; Ranieri, M.; Guinand, N.; van de Berg, R.; Carpaneto, J.; Kingma, H.; Guyot, J.-P.; Micera, S.; Perez Fornos, A.

    2016-08-01

    Objective. The vestibular system provides essential information about balance and spatial orientation via the brain to other sensory and motor systems. Bilateral vestibular loss significantly reduces quality of life, but vestibular implants (VIs) have demonstrated potential to restore lost function. However, optimal electrical stimulation strategies have not yet been identified in patients. In this study, we compared the two most common strategies, pulse amplitude modulation (PAM) and pulse rate modulation (PRM), in patients. Approach. Four subjects with a modified cochlear implant including electrodes targeting the peripheral vestibular nerve branches were tested. Charge-equivalent PAM and PRM were applied after adaptation to baseline stimulation. Vestibulo-ocular reflex eye movement responses were recorded to evaluate stimulation efficacy during acute clinical testing sessions. Main results. PAM evoked larger amplitude eye movement responses than PRM. Eye movement response axes for lateral canal stimulation were marginally better aligned with PRM than with PAM. A neural network model was developed for the tested stimulation strategies to provide insights on possible neural mechanisms. This model suggested that PAM would consistently cause a larger ensemble firing rate of neurons and thus larger responses than PRM. Significance. Due to the larger magnitude of eye movement responses, our findings strongly suggest PAM as the preferred strategy for initial VI modulation.

  13. Longitudinally excited CO2 laser with short laser pulse operating at high repetition rate

    Science.gov (United States)

    Li, Jianhui; Uno, Kazuyuki; Akitsu, Tetsuya; Jitsuno, Takahisa

    2016-11-01

    A short-pulse longitudinally excited CO2 laser operating at a high repetition rate was developed. The discharge tube was made of a 45 cm-long or 60 cm-long dielectric tube with an inner diameter of 16 mm and two metallic electrodes at the ends of the tube. The optical cavity was formed by a ZnSe output coupler with a reflectivity of 85% and a high-reflection mirror. Mixed gas (CO2:N2:He = 1:1:2) was flowed into the discharge tube. A high voltage of about 33 kV with a rise time of about 200 ns was applied to the discharge tube. At a repetition rate of 300 Hz and a gas pressure of 3.4 kPa, the 45 cm-long discharge tube produced a short laser pulse with a laser pulse energy of 17.5 mJ, a spike pulse energy of 0.2 mJ, a spike width of 153 ns, and a pulse tail length of 90 μs. The output power was 5.3 W. The laser pulse waveform did not depend on the repetition rate, but the laser beam profile did. At a low repetition rate of less than 50 Hz, the laser beam had a doughnut-like shape. However, at a high repetition rate of more than 150 Hz, the discharge concentrated at the center of the discharge tube, and the intensity at the center of the laser beam was higher. The laser beam profile depended on the distribution of the discharge. An output power of 7.0 W was achieved by using the 60 cm-long tube.

  14. CONTRASTING DOSE-RATE EFFECTS OF GAMMA-IRRADIATION ON RAT SALIVARY-GLAND FUNCTION

    NARCIS (Netherlands)

    VISSINK, A; DOWN, JD; KONINGS, AWT

    1992-01-01

    The aim of this study was to investigate the effects of Co-60 irradiation delivered at high (HDR) and low (LDR) dose-rates on rat salivary gland function. Total-body irradiation (TBI; total doses 7.5, 10 and 12.5 Gy) was applied from a Co-60 source at dose-rates of 1 cGy/min (LDR) and 40 cGy/min (HD

  15. Modeling low-dose-rate effects in irradiated bipolar-base oxides

    Energy Technology Data Exchange (ETDEWEB)

    Graves, R.J.; Cirba, C.R.; Schrimpf, R.D.; Milanowski, R.J.; Saigne, F. [Vanderbilt Univ., Nashville, TN (United States); Michez, A. [Univ. Montpellier 2 (France); Fleetwood, D.M. [Sandia National Labs., Albuquerque, NM (United States); Witczak, S.C. [Aerospace Corp., Los Angeles, CA (United States)

    1997-02-01

    A physical model is developed to quantify the contribution of oxide-trapped charge to enhanced low-dose-rate gain degradation in BJTs. Simulations show that space charge limited transport is partially responsible for the low-dose-rate enhancement.

  16. Neutron dose equivalent rate in intermediate energy heavy ion target area

    CERN Document Server

    Li Gui Sheng; Li Zong Wei; Su You Wu; Zhang Shu Mi

    2000-01-01

    The fluence rate distributions of neutrons emitted in the reactions of 50 MeV/u sup 1 sup 8 O-ion on thick Be, Cu, Au targets were measured with an activation method of threshold detectors and the neutron dose equivalent rate distributions at 1 m from the targets in intermediate energy heavy ion target area were obtained using the conversion coefficients for neutron fluence rate to ambient dose equivalent rate.

  17. A new technique in brachytherapy for the putting in operation of the radiation protection principle named ''ALARA': the P.D.R. (acronym for Pulsed Dose Rate); Une nouvelle technique en curietherapie pour la mise en oeuvre du principe de radioprotection dit ''ALARA'': le PDR

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, S.; Aletti, P.; Bellut, F.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France)

    1998-07-01

    This article presents successively the different techniques of brachytherapy and gives the radiation doses received in 1995 at the beginning of the use of the projector of iridium source and in 1997 with its partial utilization. On this base, an estimation of the number of applications using this type of apparatus and then a reduction of doses received is equally proposed. (N.C.)

  18. Use of a prototype pulse oximeter for time series analysis of heart rate variability

    Science.gov (United States)

    González, Erika; López, Jehú; Hautefeuille, Mathieu; Velázquez, Víctor; Del Moral, Jésica

    2015-05-01

    This work presents the development of a low cost pulse oximeter prototype consisting of pulsed red and infrared commercial LEDs and a broad spectral photodetector used to register time series of heart rate and oxygen saturation of blood. This platform, besides providing these values, like any other pulse oximeter, processes the signals to compute a power spectrum analysis of the patient heart rate variability in real time and, additionally, the device allows access to all raw and analyzed data if databases construction is required or another kind of further analysis is desired. Since the prototype is capable of acquiring data for long periods of time, it is suitable for collecting data in real life activities, enabling the development of future wearable applications.

  19. Variations of dose rate observed by MSL/RAD in transit to Mars

    CERN Document Server

    Guo, Jingnan; Wimmer-Schweingruber, Robert F; Hassler, Donald M; Posner, Arik; Heber, Bernd; Köhler, Jan; Rafkin, Scot; Ehresmann, Bent; Appel, Jan K; Böhm, Eckart; Böttcher, Stephan; Burmeister, Sönke; Brinza, David E; Lohf, Henning; Martin, Cesar; Reitz, Günther

    2015-01-01

    Aims: To predict the cruise radiation environment related to future human missions to Mars, the correlation between solar modulation potential and the dose rate measured by the Radiation Assessment Detector (RAD) has been analyzed and empirical models have been employed to quantify this correlation. Methods: The instrument RAD, onboard Mars Science Laboratory's (MSL) rover Curiosity, measures a broad spectrum of energetic particles along with the radiation dose rate during the 253-day cruise phase as well as on the surface of Mars. With these first ever measurements inside a spacecraft from Earth to Mars, RAD observed the impulsive enhancement of dose rate during solar particle events as well as a gradual evolution of the galactic cosmic ray (GCR) induced radiation dose rate due to the modulation of the primary GCR flux by the solar magnetic field, which correlates with long-term solar activities and heliospheric rotation. Results: We analyzed the dependence of the dose rate measured by RAD on solar modulatio...

  20. LET and dose rate effect on radiation-induced copolymerization in physical gel

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Seiko, E-mail: Nakagawa.Seiko@iri-tokyo.jp [Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064 (Japan); Taguchi, Mitsumasa; Kimura, Atsushi; Nagasawa, Naotsugu; Hiroki, Akihiro [Environmental Radiation Processing Group, Environment and Industrial Materials Research Division, Quantum Beam Science Directorate, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-09-01

    Highlights: •LET and dose rate effect on polymerization in gel was almost the same as in solution. •The ratio of the dose rate effect in the gel was higher than that in solution. •The initiation and termination processes show the difference on the dose rate effect. -- Abstract: N{sub 2}-saturated 2-propanol solutions containing styrene and maleimide were gelled by the addition of hydroxypropylcellulose and irradiated by proton, He and C-ion beams. The trend in the dose rate and LET effects on the yield and molecular weight distribution of the polymer produced in the gel was almost the same in the solution. On the contrary, the dose rate effect in the gel was higher than that in the solution. This effect was accelerated for irradiations by proton as well as heavier ion with a higher LET value.

  1. Natural background radiation and estimation of gonadal dose rate of population of Chittagong region

    Energy Technology Data Exchange (ETDEWEB)

    Mostofa, M.N.; Ahmed, J.U. (Chittagong Univ. (Bangladesh). Dept. of Physics); Ahmed, R.; Ishaque, A.M. (Nuclear Medicine Center, Chittagong (Bangladesh)); Ahmed, K. (Institute of Nuclear Medicine, Dacca (Bangladesh))

    1981-07-01

    A survey was made on the background radiation to estimate the gonadal dose rate in the district of Chittagong from the year 1978 to 80. This was done with the help of a calibrated Nuclear Chicago transistorized survey meter. The measurements were made in different types of dwellings and occupational buildings constructed with wood, straw/bamboo, tin/bamboo, tin/brick and single and multistoried buildings of brick and concrete. For measurement of outdoor radiation the investigating areas taken were the roads, fields and the Karnafuly river. The variation in the population dose rate as well as gonadal dose rate were observed in different types of dwellings and occupational buildings including outdoors. The average population dose rate including cosmic ray intensity was found to be 172.41+-8.61 mrad/year. Thus, the annual gonadal dose rate due to gamma radiation was found to be 137.92+-6.89 mrad/year.

  2. Biological impact of high-dose and dose-rate radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Maliev, V.; Popov, D. [Russian Academy of Science, Vladicaucas (Russian Federation); Jones, J.; Gonda, S. [NASA -Johnson Space Center, Houston (United States); Prasad, K.; Viliam, C.; Haase, G. [Antioxida nt Research Institute, Premier Micronutrient Corporation, Novato (United States); Kirchin, V. [Moscow State Veterinary and Biotechnology Acade my, Moscow (Russian Federation); Rachael, C. [University Space Research Association, Colorado (United States)

    2006-07-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  3. Toxicity bioassay in mice exposed to low dose-rate radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joog Sun; Gong, Eun Ji; Heo, Kyu; Yang, Kwang Mo [Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of)

    2013-04-15

    The systemic effect of radiation increases in proportion to the dose amount and rate. The association between accumulated radiation dose and adverse effects, which is derived according to continuous low dose-rate radiation exposure, is not clearly elucidated. Our previous study showed that low dose-rate radiation exposure did not cause adverse effects in BALB/c mice at dose levels of ≤2 Gy, but the testis weight decreased at a dose of 2 Gy. In this study, we studied the effects of irradiation at the low dose rate (3.49 mGy/h) in the testes of C57BL/6 mice. Mice exposed to a total dose of 0.02, 0.2, and 2 Gy were found to be healthy and did not show any significant changes in body weight and peripheral blood components. However, mice irradiated with a dose of 2 Gy had significantly decreased testis weight. Further, histological studies and sperm evaluation also demonstrated changes consistent with the findings of decreased testis weight. In fertile patients found to have arrest of sperm maturation, the seminiferous tubules lack the DNMT1 and HDAC1 protein. The decrease of DNMT1 and HDAC1 in irradiated testis may be the part of the mechanism via which low dose-rate irradiation results in teticular injury. In conclusion, despite a low dose-rate radiation, our study found that when mice testis were irradiated with 2 Gy at 3.49 mGy/h dose rate, there was significant testicular and sperm damage with decreased DNMT1 and HDAC1 expression.

  4. Temporal Variations of Air Dose Rates in East Fukushima During Japanese Fiscal Years 2012 and 2013.

    Science.gov (United States)

    Akimoto, Kazuhiro

    2017-01-01

    Temporal variations of ambient air dose rates in eastern Fukushima prefecture during Japanese fiscal years 2012 and 2013 are analyzed. The average overall variation rate of air dose rates in east Fukushima during the examined period is found to be 0.49 (51% down) compared to the theoretically predicted value 0.65 (35% down) based on physical decay of radioactive cesium nuclides. On average, local dose rates declined almost linearly for the relatively short period. Temporal characteristics of air dose rates may be classified into variation rates, peaks, spikes, and oscillations. During the examined period, a typical dose-rate curve formed a long-term peak in summer that lasted one through a few months as well as a long-term spike in winter that lasted likewise. Otherwise, occasional short-term peaks and short-term spikes, in addition to long-term oscillations, were observed. Air dose rates may be effectively modulated at short timescales mainly by precipitation. Moreover, it is likely that winds may oscillate air dose rates due to resuspension of radio-dusts.

  5. Nanosecond pulsed electric field induced dose dependent phosphatidylinositol-4,5-bisphosphate signaling and intracellular electro-sensitization.

    Science.gov (United States)

    Tolstykh, Gleb P; Tarango, Melissa; Roth, Caleb C; Ibey, Bennett L

    2017-03-01

    Previously, it was demonstrated that nanometer-sized pores (nanopores) are formed in outer cellular membranes after exposure to nanosecond electric pulses (nsEPs). We reported that plasma membrane nanoporation affects phospholipids of the cell membrane, culminating in cascading phosphoinositide phosphatidylinositol-4,5-bisphosphate (PIP2) intracellular signaling. In the current study, we show that nsEPs initiated electric field (EF) dose-dependent PIP2 hydrolysis and/or depletion from the plasma membrane. This process was confirmed using fluorescent optical probes of PIP2 hydrolysis: PLCδ-PH-EGFP and GFP-C1-PKCγ-C1a. The 50% maximum response occurs with a single 600ns pulse achieving an effective dose (ED50) of EF~8kV/cm within our model cell system. At 16.2kV/cm, the ED50 for the pulse width was 484ns. Reduction of the pulse width or EF amplitude gradually reduced the observed effect, but twenty 60ns 16.2kV/cm pulses produced an effect similar to a single 600ns pulse of the same amplitude. Propidium iodide (PI) uptake after the nsEP exposure confirmed a strong relationship between EF-induced plasma membrane impact and PIP2 depletion. These results have expanded our current knowledge of nsEPs dependent cell physiological effects, and serve as a basis for model development of new exposure standards, providing novel tools for drug independent stimulation and approaches to differential modulation of key cellular functions.

  6. Effect of different ionizing radiation dose rates on the Staphylococcal enterotoxin in mechanically deboned chicken meat

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Heliana de; Brito, Poliana de Paula; Fukuma, Henrique Takuji; Roque, Claudio Vitor; Custodio, Wilson [Brazilian Nuclear Energy Commission (CNEN-MG), Pocos de Caldas, MG (Brazil)], e-mail: hazevedo@cnen.gov.br, e-mail: pbrito@cnen.gov.br, e-mail: cvroque@cnen.gov.br, e-mail: htfukuma@cnen.gov.br, e-mail: wilsonc@cnen.gov.br; Kodama, Yasko [Nuclear and Energy Research Institute (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: ykodama@ipen.br; Miya, Norma Terugo Nago; Pereira, Jose Luiz [Campinas State University (UNICAMP), SP (Brazil). Dept. of Food Sciences], e-mail: pereira@fea.unicamp.br, e-mail: miya@fea.unicamp.br

    2009-07-01

    Samples weighing 50g each were prepared from allotments of back with skin MDCM, to the EEB contamination or not (control). Each sample of MDCM contaminated or not with EEB was conditioned in low density polyethylene bag, frozen (-18 {+-} 1 deg C) for one night in a tunnel and irradiated with gamma rays from {sup 60}Co source in this state with doses of 0.0 kGy (control), 1.5 kGy (5.7 kGy.h{sup -1} - higher dose rate, 1.8 kGy.h{sup -1} - intermediary dose rate and 0.6 kGy.h{sup -1} - lower dose rate) and 3.0 kGy (8.4 kGy.h{sup -}'1 - higher dose rate, 2.4 kGy.h{sup -1} - intermediary dose rate and 0.6 kGy.h{sup -1} - lower dose rate). Irradiated or non irradiated MDCM samples were processed to the EEB extraction, according to the VIDAS Staph enterotoxin II kit (bioMerieux) manufacturer protocol. The calculation to determinate the MDCM EEB recovery after the sample (control or irradiated) processing were carried out applying the principle of mass balance, along the whole process. Described experiment was performed in triplicate. Results showed that the irradiation process was effective to remove the MDCM EEB, to both 1.5 kGy and 3.0 kGy. According to the expected, doses of 3.0 kGy showed the highest values of MDCM EEB removal. Regarding the effect of dose rate of radiation on the removal of EEB of the MDCM, it could be observed only for samples irradiated with 1.5 kGy radiation dose; in these processing conditions, the highest value of EEB removal was obtained for samples processed with low radiation dose rate. (author)

  7. Seasonal chaotic features of pulse rate in a healthy subject and a patient after coronary stenting.

    Science.gov (United States)

    Chen, Ying; Chen, Wenxi

    2010-01-01

    This study analyzes seasonal features of pulse rate chaos in both healthy and unhealthy subjects. Analytical methods, such as numerical titration, sample entropy and spectral analysis, were used to detect and estimate the seasonal fluctuations in chaotic attributes, complexity and nonlinearity of pulse rate. Chaotic feature analyses are based on pulse rate data collected over one year from a healthy male and a male patient after coronary stenting. The results show that the mean level of pulse rate chaos in the healthy subject is lowest in winter (values of NL, DR, and SampEn are 8.1 ± 0.3%, 41.0 ± 1.2%, and 1.98 ± 0.02, separately) and highest in summer (corresponding values are 9.9 ± 0.6%, 46.8 ± 2.3%, and 2.06 ± 0.03, separately) (P chaotic dynamics that is least active in autumn (7.1 ± 0.5%, 14.8 ± 1.5%, and 0.80 ± 0.01) and more active in winter (7.7 ± 0.4%, 35.9 ± 1.9%, and 0.93 ± 0.01) and spring (9.1 ± 0.7%, 28.6 ± 2.1%, and 0.87 ± 0.01) (P chaotic features.

  8. Effect of the pulse repetition rate on fiber-assisted tissue ablation

    Science.gov (United States)

    Kang, Hyun Wook

    2016-07-01

    The effect of the pulse repetition rate on ablation performance was evaluated ex vivo at various fiber sweeping speeds for an effective 532-nm laser prostatectomy. Three pulse repetition rates (7.5, 15, and 30 kHz) at 100 W were delivered to bovine liver tissue at three sweeping speeds (2, 4, and 6 mm/s) to achieve bulky tissue removal. Ablation performance was quantitatively compared in terms of the ablation volume and the coagulation thickness. The lowest pulse repetition rate of 7.5 kHz attained the highest ablation volume (101.5 ± 12.0 mm3) and the thinnest coagulation (0.7 ± 0.1 mm) along with superficial carbonization. The highest pulse repetition rate of 30 kHz was associated with the least tissue removal (65.8 ± 5.0 mm3) and the deepest thermal denaturation (1.1 ± 0.2 mm). Quantitative evaluations of laser parameters can be instrumental in facilitating ablation efficiency and maintaining hemostatic coagulation during treatment of large-sized benign prostate hyperplasia.

  9. Monte Carlo-based revised values of dose rate constants at discrete photon energies

    Directory of Open Access Journals (Sweden)

    T Palani Selvam

    2014-01-01

    Full Text Available Absorbed dose rate to water at 0.2 cm and 1 cm due to a point isotropic photon source as a function of photon energy is calculated using the EDKnrc user-code of the EGSnrc Monte Carlo system. This code system utilized widely used XCOM photon cross-section dataset for the calculation of absorbed dose to water. Using the above dose rates, dose rate constants are calculated. Air-kerma strength S k needed for deriving dose rate constant is based on the mass-energy absorption coefficient compilations of Hubbell and Seltzer published in the year 1995. A comparison of absorbed dose rates in water at the above distances to the published values reflects the differences in photon cross-section dataset in the low-energy region (difference is up to 2% in dose rate values at 1 cm in the energy range 30-50 keV and up to 4% at 0.2 cm at 30 keV. A maximum difference of about 8% is observed in the dose rate value at 0.2 cm at 1.75 MeV when compared to the published value. S k calculations based on the compilation of Hubbell and Seltzer show a difference of up to 2.5% in the low-energy region (20-50 keV when compared to the published values. The deviations observed in the values of dose rate and S k affect the values of dose rate constants up to 3%.

  10. Multi-rate soliton pulse train generator based on novel fiber optic components

    Science.gov (United States)

    Sova, Raymond Michael

    As data rates for communication, signal processing, and optical sensing systems increase beyond 50 Gb/sec, ultra-fast optical pulse train generators will play a key role in their development. In this research, an all-fiber optical soliton pulse train generator is developed that operates at discrete rates from 50 to 400 Gb/sec with stable subpicosecond pulses. It is based on the following three novel fiber optic components: (1) all-fiber birefringence filter, (2) dual-wavelength fiber ring laser and (3) fiber-based soliton pulse train generation and compression stage. A multi-segment birefringence comb filter is developed to provide discrete tuning of the free spectral range from 0.8 to 3.2 nm and continuous tuning of the absolute position of the transmission peaks over the entire free spectral range. Two, three and four segment filters are constructed and implemented in Lyot and Lyot-Sagnac filter configurations to demonstrate the tuning properties and provide compound filters for use in the dual-wavelength fiber ring laser. Theoretical transmission functions are derived for two-segment filters. The experimental results are in excellent agreement with theoretical models based on the Jones matrix technique. The dual-wavelength laser consists of a PM amplifier, the tunable birefringence filter and a high-Q filter based on saturable absorber properties of un-pumped Erbium-doped fiber. Tunable compound birefringence filters are designed to operate the dual-wavelength laser over the entire erbium amplifier gain region (1530 to 1565 nm) with discrete tuning of the channel separation from 0.8 to 3.2 nm. Stable tunable dual-wavelength single-longitudinal mode operation is demonstrated and initial laser properties such as dual-relaxation oscillations, laser linewidth, polarization, and multi-wavelength stability are characterized. Induced modulation instability in optical fiber is used to generate pulse trains from the fiber ring laser output signal. Through modeling, the

  11. Concurrent validity of resting pulse-rate measurements: a comparison of 2 smartphone applications, the polar H7 belt monitor, and a pulse oximeter with bluetooth.

    Science.gov (United States)

    Cheatham, Scott W; Kolber, Morey J; Ernst, Michael P

    2015-05-01

    Pulse rate is commonly measured manually or with commercial wrist or belt monitors. More recently, pulse-rate monitoring has become convenient with the use of mobile technology that allows monitoring through a smartphone camera. This optical technology offers many benefits, although the clinimetric properties have not been extensively studied. Observational study of reliability Setting: University kinesiology laboratory. 30 healthy, recreationally active adults. Concurrent measurement of pulse rate using 2 smartphone applications (fingertip, face-scan,) with the Polar H7 belt and pulse oximeter. Average resting pulse rate for 5 min in 3 positions (supine, sitting, and prone). Concurrent validity in supine and standing was good between the 2 applications and the Polar H7 (intraclass correlation coefficient [ICC] .80-.98) and pulse oximeter (ICC .82-.98). For sitting, the validity was good between the fingertip application, Polar H7 (ICC .97), and pulse oximeter (ICC .97). The face-scan application had moderate validity with the Polar H7 (ICC .74) and pulse oximeter (ICC .69). The minimal detectable change (MDC90) between the fingertip application and Polar H7 ranged from 1.38 to 4.36 beats/min (BPM) and from 0.69 to 2.97 BPM for the pulse oximeter with both positions. The MDC90 between the face-scan application and Polar H7 ranged from 11.88 to 12.83 BPM and from 0.59 to 17.72 BPM for the pulse oximeter. The 95% limits of agreement suggest that the fingertip application may vary between 2.40 and 3.59 BPM with the Polar H7 and between 3.40 and 3.42 BPM with the pulse oximeter. The face-scan application may vary between 3.46 and 3.52 BPM with the Polar H7 and between 2.54 and 3.46 BPM with the pulse oximeter. Pulse-rate measurements may be effective using a fingertip application, belt monitor, and pulse oximeter. The fingertip scanner showed superior results compared with the face scanner, which only demonstrated modest validity compared with the Polar H7 and pulse

  12. Evaluation of dose equivalent rate distribution in JCO critical accident by radiation transport calculation

    CERN Document Server

    Sakamoto, Y

    2002-01-01

    In the prevention of nuclear disaster, there needs the information on the dose equivalent rate distribution inside and outside the site, and energy spectra. The three dimensional radiation transport calculation code is a useful tool for the site specific detailed analysis with the consideration of facility structures. It is important in the prediction of individual doses in the future countermeasure that the reliability of the evaluation methods of dose equivalent rate distribution and energy spectra by using of Monte Carlo radiation transport calculation code, and the factors which influence the dose equivalent rate distribution outside the site are confirmed. The reliability of radiation transport calculation code and the influence factors of dose equivalent rate distribution were examined through the analyses of critical accident at JCO's uranium processing plant occurred on September 30, 1999. The radiation transport calculations including the burn-up calculations were done by using of the structural info...

  13. SEMICONDUCTOR PHYSICS Dose-rate dependence of optically stimulated luminescence signal

    Science.gov (United States)

    Pingqiang, Wei; Zhaoyang, Chen; Yanwei, Fan; Yurun, Sun; Yun, Zhao

    2010-10-01

    Optically stimulated luminescence (OSL) is the luminescence emitted from a semiconductor during its exposure to light. The OSL intensity is a function of the total dose absorbed by the sample. The dose-rate dependence of the OSL signal of the semiconductor CaS doped Ce and Sm was studied by numerical simulation and experiments. Based on a one-trap/one-center model, the whole OSL process was represented by a series of differential equations. The dose-rate properties of the materials were acquired theoretically by solving the equations. Good coherence was achieved between numerical simulation and experiments, both of which showed that the OSL signal was independent of dose rate. This result validates that when using OSL as a dosimetry technique, the dose-rate effect can be neglected.

  14. Chirped Pulse Microwave Spectroscopy in Pulsed Uniform Supersonic Flows: Observation of K-Dependent Rates in the CL + Propyne Reaction

    Science.gov (United States)

    Ariyasingha, Nuwandi M.; Broderick, Bernadette M.; Thompson, James O. F.; Suits, Arthur

    2016-06-01

    Chirped-Pulse Fourier-transform microwave spectroscopy in uniform supersonic flows (CPUF) has been applied to study the reaction of Cl atoms with propyne. The approach utilizes broad-band microwave spectroscopy to extract structural information with MHz resolution and near universal detection, in conjunction with a Laval flow system, which offers thermalized conditions at low temperatures and high number densities. Our previous studies have exploited this approach to obtain multichannel product branching fractions in a number of polyatomic systems, with isomer and often vibrational level specificity. This report highlights an additional capability of the CPUF technique: here, the state-specific reactant depletion is directly monitored on a microsecond timescale. In doing so, a clear dependence on the rotational quantum number K in the rate of the reaction between Cl atoms and propyne is revealed. Future prospects for the technique will be discussed.

  15. INFLUENCE OF DOSE RATE ON THE CELLULAR RESPONSE TO LOW- AND HIGH-LET RADIATIONS

    Directory of Open Access Journals (Sweden)

    Anne-Sophie eWozny

    2016-03-01

    Full Text Available Nowadays, head and neck squamous cell carcinoma (HNSCC treatment failure is mostly explained by loco-regional progression or intrinsic radioresistance. Radiotherapy has recently evolved with the emergence of heavy ion radiations or new fractionation schemes of photon therapy which modify the dose-rate of treatment delivery. The aim of the present study was then to evaluate the in vitro influence of a dose rate variation during conventional radiotherapy or carbon ion hadrontherapy treatment in order to improve the therapeutic care of patient. In this regard, two HNSCC cell lines were irradiated with photons or 72MeV/n carbon ions at a dose rate of 0.5, 2 or 10Gy/min.For both radiosensitive and radioresistant cells, the change in dose rate significantly affected cell survival in response to photon exposure, this variation of radiosensitivity was associated to the number of initial and residual DNA double-strand breaks. By contrast, the dose rate change did not affect neither cell survival nor the residual DNA double-strand breaks after carbon ion irradiation. As a result, the Relative Biological Efficiency at 10% survival increased when the dose rate decreased.In conclusion, in the radiotherapy treatment of HNSCC, it is advised to remain very careful when modifying the classical schemes towards altered-fractionation. At the opposite, as the dose rate does not seem to have any effects after carbon ion exposure, there is less need to adapt hadrontherapy treatment planning during active system irradiation

  16. Occurence and implications of radiation dose-rate effects for material aging studies

    Science.gov (United States)

    Gillen, Kenneth T.; Clough, Roger L.

    A number of commercial cable materials, including ethylene propylene rubber and crosslinked polyolefin insulations and chloroprene and chlorosulfonated polyethylene jackets have been radiation aged in air and nitrogen at radiation dose rates ranging from approximately 10 3 to 10 6{rad}/{hr}. Material degradation was followed using ultimate tensile properties (elongation and tensile strength), swelling measurements and infrared spectroscopy. The tensile results indicate that in air environments radiation dose rate effects are important for all four materials, with more mechanical damage occurring as the dose rate is lowered. These results are interpreted as coming from a competition between crosslinking and oxidative scission in which scission becomes more important as the dose rate is lowered. The swelling results offer direct evidence in support of this interpretation. In addition the infrared results show increased carbonyl content at lower dose rates, also indicative of increased oxidation. The conclusions of this study have important implications for the qualification of elastomeric materials for nuclear applications, since they clearly indicate that the mechanism of degradation is quite different (and the amount usually more severe) under low dose rate exposures compared to the mechanism occurring under the high dose rate exposures normally utilized for stimulating the natural aging.

  17. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments.

    Science.gov (United States)

    Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter

    2016-05-01

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.

  18. Influence of Dose Rate on the Cellular Response to Low- and High-LET Radiations.

    Science.gov (United States)

    Wozny, Anne-Sophie; Alphonse, Gersende; Battiston-Montagne, Priscillia; Simonet, Stéphanie; Poncet, Delphine; Testa, Etienne; Guy, Jean-Baptiste; Rancoule, Chloé; Magné, Nicolas; Beuve, Michael; Rodriguez-Lafrasse, Claire

    2016-01-01

    Nowadays, head and neck squamous cell carcinoma (HNSCC) treatment failure is mostly explained by locoregional progression or intrinsic radioresistance. Radiotherapy (RT) has recently evolved with the emergence of heavy ion radiations or new fractionation schemes of photon therapy, which modify the dose rate of treatment delivery. The aim of the present study was then to evaluate the in vitro influence of a dose rate variation during conventional RT or carbon ion hadrontherapy treatment in order to improve the therapeutic care of patient. In this regard, two HNSCC cell lines were irradiated with photons or 72 MeV/n carbon ions at a dose rate of 0.5, 2, or 10 Gy/min. For both radiosensitive and radioresistant cells, the change in dose rate significantly affected cell survival in response to photon exposure. This variation of radiosensitivity was associated with the number of initial and residual DNA double-strand breaks (DSBs). By contrast, the dose rate change did not affect neither cell survival nor the residual DNA DSBs after carbon ion irradiation. As a result, the relative biological efficiency at 10% survival increased when the dose rate decreased. In conclusion, in the RT treatment of HNSCC, it is advised to remain very careful when modifying the classical schemes toward altered fractionation. At the opposite, as the dose rate does not seem to have any effects after carbon ion exposure, there is less need to adapt hadrontherapy treatment planning during active system irradiation.

  19. Impact of dose rate on clinical course in uveal melanoma after brachytherapy with ruthenium-106

    Energy Technology Data Exchange (ETDEWEB)

    Mossboeck, G.; Rauscher, T.; Langmann, G. [Medical Univ. of Graz (Austria). Dept. of Opthalmology; Winkler, P.; Kapp, K.S. [Medical Univ. of Graz (Austria). Dept. of Therapeutic Radiology and Oncology

    2007-10-15

    Background and Purpose: It has been suggested that the actual dose rate of an irradiating source may be a distinct influencing factor for the biological effect after brachytherapy with ruthenium-106 for uveal melanoma. The purpose of this study was to investigate a hypothesized impact of the dose rate on the clinical and echographic course after brachytherapy. Patients and Methods: In total, 45 patients were included in this retrospective study. According to the actual dose rate, two groups were defined: group 1 with a dose rate < 4 Gy/h and group 2 with a dose rate {>=} 4 Gy/h. Regarding age, tumor height, basal diameter, scleral and apical dose, differences between the groups were not significant. Clinical parameters, including early and late side effects, and echographic courses were compared. Results: A significantly lower metastatic rate was found in group 2. Using univariate Cox proportional hazards regression, only dose rate predicted metastatic spread significantly (p < 0.05), while in a multivariate analysis, using age at the time of treatment, greatest tumor height and greatest basal diameter as covariates, the variable dose rate was of borderline significance (p = 0.077). Patients in group 2 had more early side effects and more pronounced visual decline, but these differences were of borderline significance with p-values of 0.072 and 0.064, respectively. Conclusion: These data suggest that a higher dose rate may confer a lower risk for metastatic spread, but may be associated with more side effects and more pronounced visual decline. (orig.)

  20. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  1. Treatment Outcome of Medium-Dose-Rate Intracavitary Brachytherapy for Carcinoma of the Uterine Cervix: Comparison With Low-Dose-Rate Intracavitary Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kaneyasu, Yuko, E-mail: kaneyasu@hiroshima-u.ac.jp [Department of Radiation Oncology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima (Japan); Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Kita, Midori [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Department of Clinical Radiology, Tokyo Metropolitan Tama Medical Center, Tokyo (Japan); Okawa, Tomohiko [Evaluation and Promotion Center, Utsunomiya Memorial Hospital, Tochigi (Japan); Maebayashi, Katsuya [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Kohno, Mari [Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women' s Medical University Hospital, Tokyo (Japan); Sonoda, Tatsuo; Hirabayashi, Hisae [Department of Radiology, Tokyo Women' s Medical University Hospital, Tokyo (Japan); Nagata, Yasushi [Department of Radiation Oncology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima (Japan); Mitsuhashi, Norio [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan)

    2012-09-01

    Purpose: To evaluate and compare the efficacy of medium-dose-rate (MDR) and low-dose-rate (LDR) intracavitary brachytherapy (ICBT) for uterine cervical cancer. Methods and Materials: We evaluated 419 patients with squamous cell carcinoma of the cervix who were treated by radical radiotherapy with curative intent at Tokyo Women's Medical University from 1969 to 1999. LDR was used from 1969 to 1986, and MDR has been used since July 1987. When compared with LDR, fraction dose was decreased and fraction size was increased (1 or 2 fractions) for MDR to make the total dose of MDR equal to that of LDR. In general, the patients received a total dose of 60 to 70 Gy at Point A with external beam radiotherapy combined with brachytherapy according to the International Federation of Gynecology and Obstetrics stage. In the LDR group, 32 patients had Stage I disease, 81 had Stage II, 182 had Stage III, and 29 had Stage IVA; in the MDR group, 9 patients had Stage I disease, 19 had Stage II, 55 had Stage III, and 12 had Stage IVA. Results: The 5-year overall survival rates for Stages I, II, III, and IVA in the LDR group were 78%, 72%, 55%, and 34%, respectively. In the MDR group, the 5-year overall survival rates were 100%, 68%, 52%, and 42%, respectively. No significant statistical differences were seen between the two groups. The actuarial rates of late complications Grade 2 or greater at 5 years for the rectum, bladder, and small intestine in the LDR group were 11.1%, 5.8%, and 2.0%, respectively. The rates for the MDR group were 11.7%, 4.2%, and 2.6%, respectively, all of which were without statistical differences. Conclusion: These data suggest that MDR ICBT is effective, useful, and equally as good as LDR ICBT in daytime (about 5 hours) treatments of patients with cervical cancer.

  2. Reducing error rates in straintronic multiferroic nanomagnetic logic by pulse shaping.

    Science.gov (United States)

    Munira, Kamaram; Xie, Yunkun; Nadri, Souheil; Forgues, Mark B; Fashami, Mohammad Salehi; Atulasimha, Jayasimha; Bandyopadhyay, Supriyo; Ghosh, Avik W

    2015-06-19

    Dipole-coupled nanomagnetic logic (NML), where nanomagnets (NMs) with bistable magnetization states act as binary switches and information is transferred between them via dipole-coupling and Bennett clocking, is a potential replacement for conventional transistor logic since magnets dissipate less energy than transistors when they switch in a logic circuit. Magnets are also 'non-volatile' and hence can store the results of a computation after the computation is over, thereby doubling as both logic and memory-a feat that transistors cannot achieve. However, dipole-coupled NML is much more error-prone than transistor logic at room temperature [Formula: see text] because thermal noise can easily disrupt magnetization dynamics. Here, we study a particularly energy-efficient version of dipole-coupled NML known as straintronic multiferroic logic (SML) where magnets are clocked/switched with electrically generated mechanical strain. By appropriately 'shaping' the voltage pulse that generates strain, we show that the error rate in SML can be reduced to tolerable limits. We describe the error probabilities associated with various stress pulse shapes and discuss the trade-off between error rate and switching speed in SML.The lowest error probability is obtained when a 'shaped' high voltage pulse is applied to strain the output NM followed by a low voltage pulse. The high voltage pulse quickly rotates the output magnet's magnetization by 90° and aligns it roughly along the minor (or hard) axis of the NM. Next, the low voltage pulse produces the critical strain to overcome the shape anisotropy energy barrier in the NM and produce a monostable potential energy profile in the presence of dipole coupling from the neighboring NM. The magnetization of the output NM then migrates to the global energy minimum in this monostable profile and completes a 180° rotation (magnetization flip) with high likelihood.

  3. Relationship of HepG2 cell sensitivity to continuous low dose-rate irradiation with ATM phosphorylation

    Institute of Scientific and Technical Information of China (English)

    Quelin Mei; Jianyong Yang; Duanming Du; Zaizhong Cheng; Pengcheng liu

    2008-01-01

    Objective: To investigate the change of ATM phosphorylation in HepG2 cells and its effect on HepG2 cell survival under a continuous low dose-rate irradiation.Methods: HepG2 cells were exposed to equivalent doses of irradiation delivered at either a continuous low dose-rate (7.76 cGy/h) or a high dose-rate (4500 cGy/h).The ATM phosphorylated proteins and surviving fraction of HepG2 cell after low dose-rate irradiation were compared with that after equivalent doses of high dose-rate irradiation.Results: The phosphorylation of ATM protein was maximal at 0.5 Gy irradiation delivered at either a high dose-rate or a continuous low dose-rate.As the radiation dose increased, the phosphorylation of ATM protein decreased under continuous low dose-rate irradiation.However, the phosphorylation of ATM protein was remained stable under high dose-rate irradiation.When the phosphorylation of ATM protein under continuous low dose-rate irradiation was equal to that under high dose-rate irradiation, there was no significant difference in the surviving fraction of HepG2 cells between two ir-radiation methods (P>0.05).When the phosphorylation of ATM protein significantly decreased after continuous low dose-rate irradiation compared with that after high dose-rate irradiation, increased amounts of cell killing was found in low dose-rate irradiation (P<0.01).Conclusion: Continuous low dose-rate irradiation increases HepG2 cells radiosensitivity compared with high dose-rate irradiation.The increased amounts of cell killing following continuous low dose-rate exposures are associated with reduced ATM phosphorylated protein.

  4. DETECTORS AND EXPERIMENTAL METHODS: ELDRS and dose-rate dependence of vertical NPN transistor

    Science.gov (United States)

    Zheng, Yu-Zhan; Lu, Wu; Ren, Di-Yuan; Wang, Gai-Li; Yu, Xue-Feng; Guo, Qi

    2009-01-01

    The enhanced low-dose-rate sensitivity (ELDRS) and dose-rate dependence of vertical NPN transistors are investigated in this article. The results show that the vertical NPN transistors exhibit more degradation at low dose rate, and that this degradation is attributed to the increase on base current. The oxide trapped positive charge near the SiO2-Si interface and interface traps at the interface can contribute to the increase on base current and the two-stage hydrogen mechanism associated with space charge effect can well explain the experimental results.

  5. Image-guided high-dose-rate brachytherapy in inoperable endometrial cancer

    Science.gov (United States)

    Petsuksiri, J; Chansilpa, Y; Hoskin, P J

    2014-01-01

    Inoperable endometrial cancer may be treated with curative aim using radical radiotherapy alone. The radiation techniques are external beam radiotherapy (EBRT) alone, EBRT plus brachytherapy and brachytherapy alone. Recently, high-dose-rate brachytherapy has been used instead of low-dose-rate brachytherapy. Image-guided brachytherapy enables sufficient coverage of tumour and reduction of dose to the organs at risk, thus increasing the therapeutic ratio of treatment. Local control rates with three-dimensional brachytherapy appear better than with conventional techniques (about 90–100% and 70–90%, respectively). PMID:24807067

  6. A case of percutaneous high dose rate brachytherapy for superior pulmonary sulcus tumor

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Tamaki; Imamura, Masahiro; Murata, Takashi [Kansai Medical Univ., Moriguchi, Osaka (Japan)] [and others

    1996-07-01

    A 64-year-old man with advanced superior pulmonary sulcus tumor suffered severe unrelieved pain even after chemotherapy, external irradiation and hyperthermia. So we planned to introduce a percutaneous high dose rate brachytherapy using the microselectron HDR {sup 192}Ir. With the estimation using the Pain Score, satisfying pain relief was attainable with a combination of the percutaneous high dose rate brachytherapy and conventional treatment. So the percutaneous high dose rate brachytherapy had the possibility to contribute to the alleviation of the pain. (author)

  7. Effects of different doses of dexamethasone plus flunixin meglumine on survival rate in lethal endotoxemia

    OpenAIRE

    Er A.; Uney K.; Altan F.; Cetin G.; Yazar E.; Elmas M.

    2009-01-01

    Effects of different doses of dexamethasone plus flunixin meglumine on survival rate were investigated in lethal endotoxemia. A total of 60 Balb/C female mice were divided into 4 equal groups. Lethal endotoxemia (80-100%) was induced by lipopolysaccharide injection (Group 1, 1 mg, intraperinoneally). At 4 hours after the lipopolysaccharide injection; low-dose dexamethasone (0.6 mg/kg, SID, 5 days, intramuscularly) + flunixin meglumine (2 mg/kg, SID, 5 days, subcutaneously), normal-dose dexame...

  8. Dose rate measurement of a cobalt source 'Issledovatel' by means of Fricke dosimeter

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The results of measurements leading to the elaboration of a reliable and accurate dose rate determination for a cobalt irradiator 'Issledovatel' were presented. The dose measurements were done by means of classic Fricke dosimeter. The conclusions from measurements can be useful also for the dosimetry of other kinds of cobalt irradiators. The measurements were performed by a newly employed Laboratory for Measurements of Technological Doses staff and were a practical test of their proficiency in gamma ray dosimetry.

  9. Developmental patterns of O2 consumption, heart rate and O2 pulse in unturned eggs.

    Science.gov (United States)

    Pearson, J T; Haque, M A; Hou, P C; Tazawa, H

    1996-01-01

    The effects of failure to turn eggs on the developmental patterns of oxygen consumption (MO2), heart rate (fH) and O2 pulse during the second half of incubation of individual chicken eggs were examined. The MO2 of unturned eggs increased at a significantly lower rate than the control toward the end of prenatal incubation, and the plateau MO2 between day 17 and 19 was significantly lower than the control. Lack of turning also resulted in significant changes in the developmental patterns of fH and O2 pulse. It is suggested that the effects of lack of egg-turning on the developmental patterns of MO2 may be attributable to lower embryonic growth rate in addition to impairment of gas exchange through the chorioallantoic gas exchanger.

  10. Neutron dose rate for {sup 252} Cf AT source in medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Paredes, L.; Balcazar, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Francois, J.L. [FI-UNAM, 04510 Mexico D.F. (Mexico)

    2006-07-01

    The AAPM TG-43 modified protocol was used for the calculation of the neutron dose rate of {sup 252}Cf sources for two tissue substitute materials, five normal tissues and six tumours. The {sup 252}Cf AT source model was simulated using the Monte Carlo MCNPX code in spherical geometry for the following factors: a) neutron air kerma strength conversion factor, b) dose rate constant, c) radial dose function, d) geometry factor, e) anisotropy function and f) neutron dose rate. The calculated dose rate in water at 1 cm and 90 degrees from the source long axis, using the Watt fission spectrum, was D{sub n}(r{sub 0}, {theta}{sub 0})= 1.9160 cGy/h-{mu}g. When this value is compared with Rivard et al. calculation using MCNP4B code, 1.8730 cGy/h-{mu}g, a difference of 2.30% is obtained. The results for the reference neutron dose rate in other media show how small variations in the elemental composition between the tissues and malignant tumours, produce variations in the neutron dose rate up to 12.25%. (Author)

  11. Oligodendroglial response to ionizing radiation: Dose and dose-rate response

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.

    1991-12-01

    An in vitro system using neuroglia from neonatal rat brain was developed to examine the morphologic, immunocytochemical and biochemical response of oligodendroglia to ionizing radiation. Following acute {gamma}-irradiation at day-in-culture (DIC) 8, oligodendrocyte counts at DIC 14 were 55% to 65% of control values after 2 Gy, and 29% to 36% after 5 Gy. Counts increased to near-normal levels at DIC 21 in the 2 Gy group and to 75% of normal in the 5 Gy group. Myelin basic protein levels (MBP) at DIC 14 were 60% of control values after 2 Gy, and 40% after 5 Gy. At DIC 21, MBP after 2 Gy was 45% greater than that observed at DIC 14, but MBP, as a fraction of age-matched control values, dropped from 60% to 50%. Following 5 Gy, absolute MBP changed little between DIC 14 and DIC 21, but decreased from 40% to 25% of control cultures. The response to split-dose irradiation indicated that nearly all sublethal damage in the oligodendrocyte population (and its precursors) was repaired within 3 h to 4 h. A new compartmental cell model for radiation response in vitro of the oligodendrocyte population is proposed and examined in relation to the potential reaction to radiation injury in the brain.

  12. Oligodendroglial response to ionizing radiation: Dose and dose-rate response

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Richard P. [Univ. of California, Berkeley, CA (United States)

    1991-12-01

    An in vitro system using neuroglia from neonatal rat brain was developed to examine the morphologic, immunocytochemical and biochemical response of oligodendroglia to ionizing radiation. Following acute γ-irradiation at day-in-culture (DIC) 8, oligodendrocyte counts at DIC 14 were 55% to 65% of control values after 2 Gy, and 29% to 36% after 5 Gy. Counts increased to near-normal levels at DIC 21 in the 2 Gy group and to 75% of normal in the 5 Gy group. Myelin basic protein levels (MBP) at DIC 14 were 60% of control values after 2 Gy, and 40% after 5 Gy. At DIC 21, MBP after 2 Gy was 45% greater than that observed at DIC 14, but MBP, as a fraction of age-matched control values, dropped from 60% to 50%. Following 5 Gy, absolute MBP changed little between DIC 14 and DIC 21, but decreased from 40% to 25% of control cultures. The response to split-dose irradiation indicated that nearly all sublethal damage in the oligodendrocyte population (and its precursors) was repaired within 3 h to 4 h. A new compartmental cell model for radiation response in vitro of the oligodendrocyte population is proposed and examined in relation to the potential reaction to radiation injury in the brain.

  13. Methodology for estimating radiation dose rates to freshwater biota exposed to radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, B.G.; Frank, M.L.; O`Neal, B.R.

    1993-08-01

    The purpose of this report is to present a methodology for evaluating the potential for aquatic biota to incur effects from exposure to chronic low-level radiation in the environment. Aquatic organisms inhabiting an environment contaminated with radioactivity receive external radiation from radionuclides in water, sediment, and from other biota such as vegetation. Aquatic organisms receive internal radiation from radionuclides ingested via food and water and, in some cases, from radionuclides absorbed through the skin and respiratory organs. Dose rate equations, which have been developed previously, are presented for estimating the radiation dose rate to representative aquatic organisms from alpha, beta, and gamma irradiation from external and internal sources. Tables containing parameter values for calculating radiation doses from selected alpha, beta, and gamma emitters are presented in the appendix to facilitate dose rate calculations. The risk of detrimental effects to aquatic biota from radiation exposure is evaluated by comparing the calculated radiation dose rate to biota to the U.S. Department of Energy`s (DOE`s) recommended dose rate limit of 0.4 mGy h{sup {minus}1} (1 rad d{sup {minus}1}). A dose rate no greater than 0.4 mGy h{sup {minus}1} to the most sensitive organisms should ensure the protection of populations of aquatic organisms. DOE`s recommended dose rate is based on a number of published reviews on the effects of radiation on aquatic organisms that are summarized in the National Council on Radiation Protection and Measurements Report No. 109 (NCRP 1991). DOE recommends that if the results of radiological models or dosimetric measurements indicate that a radiation dose rate of 0. 1 mGy h{sup {minus}1} will be exceeded, then a more detailed evaluation of the potential ecological consequences of radiation exposure to endemic populations should be conducted.

  14. Methodology for estimating radiation dose rates to freshwater biota exposed to radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, B.G.; Frank, M.L.; O`Neal, B.R.

    1993-08-01

    The purpose of this report is to present a methodology for evaluating the potential for aquatic biota to incur effects from exposure to chronic low-level radiation in the environment. Aquatic organisms inhabiting an environment contaminated with radioactivity receive external radiation from radionuclides in water, sediment, and from other biota such as vegetation. Aquatic organisms receive internal radiation from radionuclides ingested via food and water and, in some cases, from radionuclides absorbed through the skin and respiratory organs. Dose rate equations, which have been developed previously, are presented for estimating the radiation dose rate to representative aquatic organisms from alpha, beta, and gamma irradiation from external and internal sources. Tables containing parameter values for calculating radiation doses from selected alpha, beta, and gamma emitters are presented in the appendix to facilitate dose rate calculations. The risk of detrimental effects to aquatic biota from radiation exposure is evaluated by comparing the calculated radiation dose rate to biota to the U.S. Department of Energy`s (DOE`s) recommended dose rate limit of 0.4 mGy h{sup {minus}1} (1 rad d{sup {minus}1}). A dose rate no greater than 0.4 mGy h{sup {minus}1} to the most sensitive organisms should ensure the protection of populations of aquatic organisms. DOE`s recommended dose rate is based on a number of published reviews on the effects of radiation on aquatic organisms that are summarized in the National Council on Radiation Protection and Measurements Report No. 109 (NCRP 1991). DOE recommends that if the results of radiological models or dosimetric measurements indicate that a radiation dose rate of 0. 1 mGy h{sup {minus}1} will be exceeded, then a more detailed evaluation of the potential ecological consequences of radiation exposure to endemic populations should be conducted.

  15. Methodology for Estimating Radiation Dose Rates to Freshwater Biota Exposed to Radionuclides in the Environment

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, B.G.

    1993-01-01

    The purpose of this report is to present a methodology for evaluating the potential for aquatic biota to incur effects from exposure to chronic low-level radiation in the environment. Aquatic organisms inhabiting an environment contaminated with radioactivity receive external radiation from radionuclides in water, sediment, and from other biota such as vegetation. Aquatic organisms receive internal radiation from radionuclides ingested via food and water and, in some cases, from radionuclides absorbed through the skin and respiratory organs. Dose rate equations, which have been developed previously, are presented for estimating the radiation dose rate to representative aquatic organisms from alpha, beta, and gamma irradiation from external and internal sources. Tables containing parameter values for calculating radiation doses from selected alpha, beta, and gamma emitters are presented in the appendix to facilitate dose rate calculations. The risk of detrimental effects to aquatic biota from radiation exposure is evaluated by comparing the calculated radiation dose rate to biota to the U.S. Department of Energy's (DOE's) recommended dose rate limit of 0.4 mGy h{sup -1} (1 rad d{sup -1}). A dose rate no greater than 0.4 mGy h{sup -1} to the most sensitive organisms should ensure the protection of populations of aquatic organisms. DOE's recommended dose rate is based on a number of published reviews on the effects of radiation on aquatic organisms that are summarized in the National Council on Radiation Protection and Measurements Report No. 109 (NCRP 1991). The literature identifies the developing eggs and young of some species of teleost fish as the most radiosensitive organisms. DOE recommends that if the results of radiological models or dosimetric measurements indicate that a radiation dose rate of 0.1 mGy h{sup -1} will be exceeded, then a more detailed evaluation of the potential ecological consequences of radiation exposure to endemic

  16. Methodology for Estimating Radiation Dose Rates to Freshwater Biota Exposed to Radionuclides in the Environment

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, B.G.

    1993-01-01

    The purpose of this report is to present a methodology for evaluating the potential for aquatic biota to incur effects from exposure to chronic low-level radiation in the environment. Aquatic organisms inhabiting an environment contaminated with radioactivity receive external radiation from radionuclides in water, sediment, and from other biota such as vegetation. Aquatic organisms receive internal radiation from radionuclides ingested via food and water and, in some cases, from radionuclides absorbed through the skin and respiratory organs. Dose rate equations, which have been developed previously, are presented for estimating the radiation dose rate to representative aquatic organisms from alpha, beta, and gamma irradiation from external and internal sources. Tables containing parameter values for calculating radiation doses from selected alpha, beta, and gamma emitters are presented in the appendix to facilitate dose rate calculations. The risk of detrimental effects to aquatic biota from radiation exposure is evaluated by comparing the calculated radiation dose rate to biota to the U.S. Department of Energy's (DOE's) recommended dose rate limit of 0.4 mGy h{sup -1} (1 rad d{sup -1}). A dose rate no greater than 0.4 mGy h{sup -1} to the most sensitive organisms should ensure the protection of populations of aquatic organisms. DOE's recommended dose rate is based on a number of published reviews on the effects of radiation on aquatic organisms that are summarized in the National Council on Radiation Protection and Measurements Report No. 109 (NCRP 1991). The literature identifies the developing eggs and young of some species of teleost fish as the most radiosensitive organisms. DOE recommends that if the results of radiological models or dosimetric measurements indicate that a radiation dose rate of 0.1 mGy h{sup -1} will be exceeded, then a more detailed evaluation of the potential ecological consequences of radiation exposure to endemic

  17. Determination of dose rates in beta radiation fields using extrapolation chamber and GM counter

    DEFF Research Database (Denmark)

    Borg, J.; Christensen, P.

    1995-01-01

    of depth-dose profiles from different beta radiation fields with E(max) values down to 156 keV. Results are also presented from studies of GM counters for use as survey instruments for monitoring beta dose rates at the workplace. Advantages of GM counters are a simple measurement technique and high...

  18. Rate equations for nitrogen molecules in ultrashort and intense x-ray pulses

    CERN Document Server

    Liu, Ji-Cai; Cederbaum, Lorenz S; Cryan, James P; Glownia, James M; Schafer, Kenneth J; Buth, Christian

    2015-01-01

    We study theoretically the molecular dynamics of nitrogen molecules (N$_2$) exposed to x rays at a wavelength of 1.1 nm (1100 eV photon energy) from the Linac Coherent Light Source (LCLS) free electron laser. Molecular rate equations are derived to describe the intertwined photoionization, decay, and dissociation processes occurring for N2 in intense and ultrafast x rays from LCLS. This model complements our earlier phenomenological approaches, the single-atom, symmetric-sharing, and fragmentation-matrix models of J. Chem. Phys. $\\mathbf{136}$, 214310 (2012). Our rate-equations are used to obtain the effective pulse energy at the sample and the time scale for the dissociation of the metastable dication N$_2^{2+}$. This leads to a very good agreement between the theoretically and experimentally obtained ion yields and, consequently, the average charge states. The effective pulse energy is found to decrease with shortening pulse duration. This variation in the effective pulse energy together with a change in th...

  19. Environmental dose rate assessment of ITER using the Monte Carlo method

    Directory of Open Access Journals (Sweden)

    Karimian Alireza

    2014-01-01

    Full Text Available Exposure to radiation is one of the main sources of risk to staff employed in reactor facilities. The staff of a tokamak is exposed to a wide range of neutrons and photons around the tokamak hall. The International Thermonuclear Experimental Reactor (ITER is a nuclear fusion engineering project and the most advanced experimental tokamak in the world. From the radiobiological point of view, ITER dose rates assessment is particularly important. The aim of this study is the assessment of the amount of radiation in ITER during its normal operation in a radial direction from the plasma chamber to the tokamak hall. To achieve this goal, the ITER system and its components were simulated by the Monte Carlo method using the MCNPX 2.6.0 code. Furthermore, the equivalent dose rates of some radiosensitive organs of the human body were calculated by using the medical internal radiation dose phantom. Our study is based on the deuterium-tritium plasma burning by 14.1 MeV neutron production and also photon radiation due to neutron activation. As our results show, the total equivalent dose rate on the outside of the bioshield wall of the tokamak hall is about 1 mSv per year, which is less than the annual occupational dose rate limit during the normal operation of ITER. Also, equivalent dose rates of radiosensitive organs have shown that the maximum dose rate belongs to the kidney. The data may help calculate how long the staff can stay in such an environment, before the equivalent dose rates reach the whole-body dose limits.

  20. On the dose-rate estimate of carbonate-rich sediments for trapped charge dating

    Energy Technology Data Exchange (ETDEWEB)

    Nathan, R.P. [Research Laboratory for Archaeology and the History of Art, 6 Keble Road, Oxford OX1 3QJ (United Kingdom); Mauz, B. [Department of Geography, University of Liverpool, Liverpool L69 7ZT (United Kingdom)], E-mail: mauz@liv.ac.uk

    2008-01-15

    In a wide range of environmental conditions sediments are subject to changing water content and carbonate cementation during burial. Trapped charge dating of these carbonate-rich deposits requires the determination of a dose rate which is not constant during burial because sediments were subject to post-depositional geochemical alterations. The dose-rate model established in this study assumes linear increase of carbonate mass and linear decrease of water mass in pores between sediment particles during burial. Numerical modelling assesses the effect of carbonate and water on the infinite-matrix dose rate as a function of time. Sensitivity testing of the system indicated that water and carbonate content have the greatest effect on the resulting dose rate, followed by the timing of onset and completion of carbonate formation. As a consequence, a comprehensive re-calculation of the water correction factors was undertaken. It revealed a 5% lower value for the annual beta dose and a 10% lower value for the annual gamma dose compared to values formulated by Zimmerman [1971. Thermoluminescence dating using fine grains from pottery. Archaeometry 13, 29-52]. The dose-rate model was tested using samples from geologically well-constrained coastal sites. The differences between onset and final dose rate were up to 30% resulting in differences between modelled and conventional optical ages between 2% and 15% depending on the final (today's) water and carbonate content. The divergence of dates may be greater under certain conditions. The dose-rate model can be applied to a wide range of contexts similar to those considered in this case study.

  1. Study of the effect of high dose rate on tissue equivalent proportional counter microdosimetric measurements in mixed photon and neutron fields

    Science.gov (United States)

    Aslam; Qashua, N.; Waker, A. J.

    2011-10-01

    This study describes the measurement of lineal energy spectra carried out with a 5.1 cm (2 in.) diameter spherical tissue equivalent proportional counter (TEPC) simulating 2 μm tissue equivalent (TE) site diameter in low energy mixed photon-neutron fields with varying dose rates generated by employing the McMaster University 1.25 MV double stage Tandetron accelerator. The 7Li (p, n) 7Be reaction was employed to generate a variety of mixed fields of photons and low energy neutrons using proton beam energy ranging 1.89-2.56 MeV. The dose rate at a given beam energy was varied by changing the beam current. Dose rates that resulted in dead times as high as 75% were employed to study the effect of dose rate on quality, microdosimetric averages ( y¯F and y¯D), absorbed dose and dose equivalent. We have observed that high dose rates due to both photons and neutrons in a mixed field of radiation result in pile up of pulses and distort the lineal energy spectrum measured under these conditions. The pile up effect and hence the distortion in the lineal energy spectrum becomes prominent with dose rates, which result in dead times larger than 25% for the high linear energy transfer (LET) radiation component. Intense neutron fields, which may amount to 75% dead time, could result in a 50% or even larger increase in the values of the microsdosimetric averages and the neutron quality factor. This study demonstrates moderate dose rates that do not result in dead times of more than 20-25% due to either of the component radiation or due to both components of mixed field radiation generate results that are acceptable for radiation monitoring.

  2. Dose rate effects in radiation degradation of polymer-based cable materials

    Science.gov (United States)

    Plaček, V.; Bartoníček, B.; Hnát, V.; Otáhal, B.

    2003-08-01

    Cable ageing under the nuclear power plant (NPP) conditions must be effectively managed to ensure that the required plant safety and reliability are maintained throughout the plant service life. Ionizing radiation is one of the main stressors causing age-related degradation of polymer-based cable materials in air. For a given absorbed dose, radiation-induced damage to a polymer in air environment usually depends on the dose rate of the exposure. In this work, the effect of dose rate on the degradation rate has been studied. Three types of NPP cables (with jacket/insulation combinations PVC/PVC, PVC/PE, XPE/XPE) were irradiated at room temperature using 60Co gamma ray source at average dose rates of 7, 30 and 100 Gy/h with the doses up to 590 kGy. The irradiated samples have been tested for their mechanical properties, thermo-oxidative stability (using differential scanning calorimetry, DSC), and density. In the case of PVC and PE samples, the tested properties have shown evident dose rate effects, while the XPE material has shown no noticeable ones. The values of elongation at break and the thermo-oxidative stability decrease with the advanced degradation, density tends to increase with the absorbed dose. For XPE samples this effect can be partially explained by the increase of crystallinity. It was tested by the DSC determination of the crystalline phase amount.

  3. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  4. Thermal-stress effects on enhanced low-dose-rate sensitivity of linear bipolar circuits

    Energy Technology Data Exchange (ETDEWEB)

    SHANEYFELT,MARTY R.; SCHWANK,JAMES R.; WITCZAK,STEVEN C.; RIEWE,LEONARD CHARLES; WINOKUR,PETER S.; HASH,GERALD L.; PEASE,R.L.; FLEETWOOD,D.M.

    2000-02-17

    Thermal-stress effects are shown to have a significant impact on the enhanced low-dose-rate sensitivity of linear bipolar circuits. Implications of these results on hardness assurance testing and mechanisms are discussed.

  5. establishment of background radiation dose rate in the vicinity of the ...

    African Journals Online (AJOL)

    nb

    radiation dose rate data prior to commencement of uranium mining activities. Twenty stations in seven ... exploration activities in this period of rising uranium demand .... Magnesium Borate (MgB407) (Mathur 1983). In this study, calcium ...

  6. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  7. Panthere V2: Multipurpose Simulation Software for 3D Dose Rate Calculations

    Science.gov (United States)

    Penessot, Gaël; Bavoil, Éléonore; Wertz, Laurent; Malouch, Fadhel; Visonneau, Thierry; Dubost, Julien

    2017-09-01

    PANTHERE is a multipurpose radiation protection software developed by EDF to calculate gamma dose rates in complex 3D environments. PANTHERE takes a key role in the EDF ALARA process, enabling to predict dose rates and to organize and optimize operations in high radiation environments. PANTHERE is also used for nuclear waste characterization, transport of nuclear materials, etc. It is used in most of the EDF engineering units and their design service providers and industrial partners.

  8. The Influence of Radon (Gas and Progeny) and Weather Conditions on Ambient Dose Equivalent Rate.

    Science.gov (United States)

    Márquez, J L; Benito, G; Saez, J C; Navarro, N; Alvarez, A; Quiñones, J

    2016-08-13

    The purpose of this study is to identify the influence of radon (gas and progeny) on the ambient dose equivalent rate measured at the reference station ESMERALDA, where continuous measurements of the ambient dose equivalent rate (every 10 min) combined with activity concentration measurements of radon gas and radon progeny as well as meteorological parameters have been collected. This study has been performed using a correlation study based on a principal components analysis and the Spearman's rank correlation coefficient.

  9. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  10. Impact on ambient dose rate in metropolitan Tokyo from the Fukushima Daiichi Nuclear Power Plant accident.

    Science.gov (United States)

    Inoue, Kazumasa; Tsuruoka, Hiroshi; Van Le, Tan; Arai, Moeko; Saito, Kyoko; Fukushi, Masahiro

    2016-07-01

    A car-borne survey was made in metropolitan Tokyo, Japan, in December 2014 to estimate external dose. This survey was conducted for all municipalities of Tokyo and the results were compared with measurements done in 2003. The ambient dose rate measured in the whole area of Tokyo in December 2014 was 60 nGy h(-1) (23-142 nGy h(-1)), which was 24% higher than the rate in 2003. Higher dose rates (>70 nGy h(-1)) were observed on the eastern and western ends of Tokyo; furthermore, the contribution ratio from artificial radionuclides ((134)Cs and (137)Cs) to ambient dose rate in eastern Tokyo was twice as high as that of western Tokyo. Based on the measured ambient dose rate, the effective dose rate after the accident was estimated to be 0.45 μSv h(-1) in Tokyo. This value was 22% higher than the value before the accident as of December 2014.

  11. Determination of alpha dose rate profile at the HLW nuclear glass/water interface

    Energy Technology Data Exchange (ETDEWEB)

    Mougnaud, S., E-mail: sarah.mougnaud@cea.fr [CEA Marcoule, DEN/DTCD/SECM, BP 17171, 30207 Bagnols-sur-Cèze cedex (France); Tribet, M.; Rolland, S. [CEA Marcoule, DEN/DTCD/SECM, BP 17171, 30207 Bagnols-sur-Cèze cedex (France); Renault, J.-P. [CEA Saclay, NIMBE UMR 3685 CEA/CNRS, 91191 Gif-sur-Yvette cedex (France); Jégou, C. [CEA Marcoule, DEN/DTCD/SECM, BP 17171, 30207 Bagnols-sur-Cèze cedex (France)

    2015-07-15

    Highlights: • The nuclear glass/water interface is studied. • The way the energy of alpha particles is deposited is modeled using MCNPX code. • A model giving dose rate profiles at the interface using intrinsic data is proposed. • Bulk dose rate is a majoring estimation in alteration layer and in surrounding water. • Dose rate is high in small cracks; in larger ones irradiated volume is negligible. - Abstract: Alpha irradiation and radiolysis can affect the alteration behavior of High Level Waste (HLW) nuclear glasses. In this study, the way the energy of alpha particles, emitted by a typical HLW glass, is deposited in water at the glass/water interface is investigated, with the aim of better characterizing the dose deposition at the glass/water interface during water-induced leaching mechanisms. A simplified chemical composition was considered for the nuclear glass under study, wherein the dose rate is about 140 Gy/h. The MCNPX calculation code was used to calculate alpha dose rate and alpha particle flux profiles at the glass/water interface in different systems: a single glass grain in water, a glass powder in water and a water-filled ideal crack in a glass package. Dose rate decreases within glass and in water as distance to the center of the grain increases. A general model has been proposed to fit a dose rate profile in water and in glass from values for dose rate in glass bulk, alpha range in water and linear energy transfer considerations. The glass powder simulation showed that there was systematic overlapping of radiation fields for neighboring glass grains, but the water dose rate always remained lower than the bulk value. Finally, for typical ideal cracks in a glass matrix, an overlapping of irradiation fields was observed while the crack aperture was lower than twice the alpha range in water. This led to significant values for the alpha dose rate within the crack volume, as long as the aperture remained lower than 60 μm.

  12. Removal of Cryptosporidium sized particle under different filtration temperature, flow rate and alum dosing

    Institute of Scientific and Technical Information of China (English)

    XU Guo-ren; Fitzpatrick S. B. Caroline; Gregory John; DENG Lin-yu

    2007-01-01

    Recent Cryptosporidium outbreaks have highlighted concerns about filter efficiency and in particular particle breakthrough. It is essential to ascertain the causes of Cryptosporidium sized particle breakthrough for Cryptosporidium cannot be destroyed by conventional chlorine disinfection. This research tried to investigate the influence of temperature, flow rate and chemical dosing on particle breakthrough during filtration. The results showed that higher temperatures and coagulant doses could reduce particle breakthrough. The increase of filtration rate made the residual particle counts become larger. There was an optimal dose in filtration and was well correlated to ζ potential.

  13. Spectral-temporal encoding and decoding of the femtosecond pulses sequences with a THz repetition rate

    Science.gov (United States)

    Tcypkin, A. N.; Putilin, S. E.

    2017-01-01

    Experimental and numerical modeling techniques demonstrated the possibilities of the spectral-time encoding and decoding for time division multiplexing sequence of femtosecond subpulses with a repetition rate of up to 6.4 THz. The sequence was formed as a result of the interference of two phase-modulated pulses. We report the limits of the application of the developed method of controlling formed sequence at the spectral-temporal coding.

  14. High repetition rate, compact micro-pulse all-solid-state laser

    Institute of Scientific and Technical Information of China (English)

    Yutong Feng; Junqing Meng; Weibiao Chen

    2007-01-01

    A high repetition rate, compact micro-pulse all-solid-state laser is designed. The diffusion bonded crystal of YAG, Nd:YAG, and Cr4+:YAG is taken as a monolithic cavity. The optimized initial transmission,output coupling, and pumping size of Cr4+:YAG are calculated. The experimental results show that the laser satisfies the requirement of a spaceborne laser range finder.

  15. Assessment of Environmental Gamma Radiation Dose Rate in Ardabil and Sarein in 2009

    Directory of Open Access Journals (Sweden)

    M Alighadri

    2011-10-01

    Full Text Available Background and Objectives: Gamma rays, the most energetic photons within the any other wave in the electromagnetic spectrum, pose enough energy to form charged particles and adversely affect human health. Provided that the external exposure of human beings to natural environmental gamma radiation normally exceeds that from all man-made sources combined, environmental gamma dose rate and corresponding annual effective dose were determined in the cities of Ardabil and Sar Ein.Materials and Methods: Outdoor environmental gamma dose rates were measured using an Ion Chamber Survey Meter in 48 selected locations (one in city center and the remaining in cardinal and ordinal directions in Ardabil and Sar Ein. Ten more locations were monitored along the hot springs effluent in Sar Ein. Measurements of gamma radiation dose rate were performed at 20 and 100 cm above the ground for a period of one hour.Results: Average outdoor environmental gamma dose rate were determined as 265, 219, and 208  for Ardabil, Sar Ein, and along the hot spring effluent, respectively. The annual affective dose for Ardabil and Sar Ein residents were estimated to be 1.45 and 1.39 mSv, respectively.Conclusion: Calculated annual effective dose of 1.49 and 1.35 are appreciably higher than the population weighted average exposure to environmental gamma radiation worldwide and that analysis of soil content to different radionuclide is suggested.

  16. Determination of alpha dose rate profile at the HLW nuclear glass/water interface

    Science.gov (United States)

    Mougnaud, S.; Tribet, M.; Rolland, S.; Renault, J.-P.; Jégou, C.

    2015-07-01

    Alpha irradiation and radiolysis can affect the alteration behavior of High Level Waste (HLW) nuclear glasses. In this study, the way the energy of alpha particles, emitted by a typical HLW glass, is deposited in water at the glass/water interface is investigated, with the aim of better characterizing the dose deposition at the glass/water interface during water-induced leaching mechanisms. A simplified chemical composition was considered for the nuclear glass under study, wherein the dose rate is about 140 Gy/h. The MCNPX calculation code was used to calculate alpha dose rate and alpha particle flux profiles at the glass/water interface in different systems: a single glass grain in water, a glass powder in water and a water-filled ideal crack in a glass package. Dose rate decreases within glass and in water as distance to the center of the grain increases. A general model has been proposed to fit a dose rate profile in water and in glass from values for dose rate in glass bulk, alpha range in water and linear energy transfer considerations. The glass powder simulation showed that there was systematic overlapping of radiation fields for neighboring glass grains, but the water dose rate always remained lower than the bulk value. Finally, for typical ideal cracks in a glass matrix, an overlapping of irradiation fields was observed while the crack aperture was lower than twice the alpha range in water. This led to significant values for the alpha dose rate within the crack volume, as long as the aperture remained lower than 60 μm.

  17. On-site gamma dose rates at the Andreeva Bay shore technical base, northwest Russia.

    Science.gov (United States)

    Reistad, O; Dowdall, M; Standring, W J F; Selnaes, Ø G; Hustveit, S; Steinhusen, F; Sørlie, A

    2008-07-01

    The spent nuclear fuel (SNF) and radioactive waste (RAW) storage facility at Andreeva Bay shore technical base (STB) is one of the largest and most hazardous nuclear legacy sites in northwest Russia. Originally commissioned in the 1960s the facility now stores large amounts of SNF and RAW associated with the Russian Northern Fleet of nuclear powered submarines. The objective of the present study was to map ambient gamma dose rates throughout the facility, in particular at a number of specific sites where SNF and RAW are stored. The data presented here are taken from a Norwegian-Russian collaboration enabling the first publication in the scientific literature of the complete survey of on-site dose rates. Results indicate that elevated gamma dose rates are found primarily at discrete sites within the facility; maximum dose rates of up to 1000 microSv/h close to the ground (0.1m) and up to 3000 microSv/h at 1m above ground were recorded, higher doses at the 1m height being indicative primarily of the presence of contaminated equipment as opposed to ground contamination. Highest dose rates were measured at sites located in the immediate vicinity of buildings used for storing SNF and sites associated with storage of solid and liquid radioactive wastes. Elevated dose rates were also observed near the former channel of a small brook that became heavily contaminated as a result of radioactive leaks from the SNF storage at Building 5 starting in 1982. Isolated patches of elevated dose rates were also observed throughout the STB. A second paper detailing the radioactive soil contamination at the site is published in this issue of Journal of Environmental Radioactivity.

  18. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  19. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahanas, M [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Baltas, D [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Zamboglou, N [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany)

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  20. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect of redu...

  1. Experiences of high dose rate interstitial brachytherapy for carcinoma of the mobile tongue

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroshi; Inoue, Toshihiko; Yamazaki, Hideya (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1994-03-01

    Interstitial brachytherapy was conducted for mobile tongue carcinoma using a high dose rate remote afterloading machine with small [sup 192]I source. Detailed method, named as 'linked double-botton technique', is to approach from submandibular skin by an open-ended stainless steel needles to the tongue lesion, and to replace each needle into flexible nylon tube from the oral cavity. Delivered dose was 60 Gy/10 Fr./5-6 days at the distance 5 mm from the source plane. Ten patients with mobile tongue carcinoma Tl-2N0 were treated with this method from October 1991 through August 1992. Local was uncontrolled in one patient, in whom the lesion was combined with leukoplakia at both lateral borders of the tongue. This was in accordance with the result in low dose rate treatment. This can be a substitute to low dose rate system for treatment of mobile tongue carcinoma. (author).

  2. Effect of Radiocesium Transfer on Ambient Dose Rate in Forest Environment

    Science.gov (United States)

    Kato, Hiroaki; Onda, Yuichi; Loffredo, Nicolas; Hisadome, Keigo; Kawamori, Ayumi

    2014-05-01

    We investigated the transfer of canopy-intercepted radiocesium to the forest floor following the Fukushima Daiichi nuclear power plant accident. The cesium-137 (Cs-137) contents of throughfall, stemflow, and litterfall were monitored in two coniferous stands (plantation of Japanese cedar) and a deciduous broad-leaved forest stand (beech with red pine). We also measured an ambient dose rate at different height in the forest by using a survey meter (TCS-172B, Hitachi-Aloka Medical, LTD.) and a portable Ge gamma-ray detector (Detective-DX-100T, Ortec, Ametek, Inc.). In decreasing order of total Cs-137 deposition from the canopy to forest floor were the mature cedar stand, the young cedar stand, and the broad-leaved forest. The ambient dose rate in forest exhibited height dependency and its vertical distribution varied by forest type and stand age. The ambient dose rate showed an exponential decrease with time for all the forest sites, however the decreasing trend differed depending on the height of dose measurement and forest type. The ambient dose rates at the canopy (approx. 10 m-) decreased earlier than physical attenuation of radiocesium, whereas those at the forest floor varied among three forest stands. These data suggested that an ambient dose rate in forest environment can be variable in spatially and temporally reflecting the transfer of radiocesium from canopy to forest floor.

  3. High dose rate endobronchial brachytherapy: a curative treatment; La curietherapie endobronchique de haut debit de dose: un traitement curatif

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Spaeth, D.; Winnefeld, J. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Menard, O. [Centre Hospitalier Universitaire Nancy-Brabois, 54 - Vandoeuvre-les-Nancy (France)

    2000-06-01

    New endobronchial techniques of treatment allow a good unblocking. Nevertheless, only high dose rate brachytherapy delivers a curative treatment for invasive carcinomas. This study analyses the results of the first 33 consecutive patients treated with curative intent by this technique from 1994 to 1997, and followed-up more than one year. Thirty-seven lesions were treated, with usual schedule delivering 30 Gy at 1 cm depth in six fractions and three to five weeks. All the patients were meticulously selected on the local involvement of the tumour and absolute contraindications to a surgical treatment. All of them have a pulmonary disease history or a general contraindication. With a 14-month follow-up, the local control at two months after the treatment was 95 % (endoscopic and histologic), and 90 % of the patients presented a prolonged local control. Four patients died of the treated cancer, another of a controlateral cancer. Ten patients died of another disease, five of them from a respiratory insufficiency. The overall survival rate at two years was 53 % and the specific survival rate 80 %. The acute tolerance was good, without incident. Asymptomatic bronchial stenoses, described by endoscopic follow-up, were described for seven patients. We conclude that, on the basis of a good selection of the patients, and a respect of the indications, high dose rate endobronchial brachytherapy is an effective curative treatment. It offers a new curative option and must be proposed for the small invasive carcinomas in non-operable patients. (author)

  4. Multi-Level Effects of Low Dose Rate Ionizing Radiation on Southern Toad, Anaxyrus [Bufo] terrestris.

    Directory of Open Access Journals (Sweden)

    Karolina Stark

    Full Text Available Despite their potential vulnerability to contaminants from exposure at multiple life stages, amphibians are one of the least studied groups of vertebrates in ecotoxicology, and research on radiation effects in amphibians is scarce. We used multiple endpoints to assess the radiosensitivity of the southern toad (Anaxyrus [Bufo] terrestris during its pre-terrestrial stages of development -embryonic, larval, and metamorphic. Toads were exposed, from several hours after oviposition through metamorphosis (up to 77 days later, to four low dose rates of 137Cs at 0.13, 2.4, 21, and 222 mGy d-1, resulting in total doses up to 15.8 Gy. Radiation treatments did not affect hatching success of embryos, larval survival, or the length of the larval period. The individual family variation in hatching success of embryos was larger than the radiation response. In contrast, newly metamorphosed individuals from the higher dose-rate treatments had higher mass and mass/length body indices, a measure which may relate to higher post-metamorphic survival. The increased mass and index at higher dose rates may indicate that the chronic, low dose rate radiation exposures triggered secondary responses. Additionally, the increases in growth were linked to a decrease in DNA damage (as measured by the Comet Assay in red blood cells at a dose rate of 21 mGy d-1 and a total dose of 1.1 Gy. In conclusion, the complex effects of low dose rates of ionizing radiation may trigger growth and cellular repair mechanisms in amphibian larvae.

  5. Production rate enhancement of size-tunable silicon nanoparticles by temporally shaping femtosecond laser pulses in ethanol.

    Science.gov (United States)

    Li, Xin; Zhang, Guangming; Jiang, Lan; Shi, Xuesong; Zhang, Kaihu; Rong, Wenlong; Duan, Ji'an; Lu, Yongfeng

    2015-02-23

    This paper proposes an efficient approach for production-rate enhancement and size reduction of silicon nanoparticles produced by femtosecond (fs) double-pulse ablation of silicon in ethanol. Compared with a single pulse, the production rate is ~2.6 times higher and the mean size of the NPs is reduced by ~1/5 with a delay of 2 ps. The abnormal enhancement in the production rate is obtained at pulse delays Δt > 200 fs. The production-rate enhancement is mainly attributed to high photon absorption efficiency. It is caused by an increase in localized transient electron density, which results from the first sub-pulse ionization of ethanol molecules before the second sub-pulse arrives. The phase-change mechanism at a critical point might reduce nanoparticle size.

  6. Dose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter

    CERN Document Server

    Khachatryan, V.

    2016-01-01

    We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.

  7. 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage.

    Science.gov (United States)

    Ricotti, Rosalinda; Vavassori, Andrea; Bazani, Alessia; Ciardo, Delia; Pansini, Floriana; Spoto, Ruggero; Sammarco, Vittorio; Cattani, Federica; Baroni, Guido; Orecchia, Roberto; Jereczek-Fossa, Barbara Alicja

    2016-12-01

    Dosimetric assessment of high dose rate (HDR) brachytherapy applicators, printed in 3D with acrylonitrile butadiene styrene (ABS) at different infill percentage. A low-cost, desktop, 3D printer (Hamlet 3DX100, Hamlet, Dublin, IE) was used for manufacturing simple HDR applicators, reproducing typical geometries in brachytherapy: cylindrical (common in vaginal treatment) and flat configurations (generally used to treat superficial lesions). Printer accuracy was investigated through physical measurements. The dosimetric consequences of varying the applicator's density by tuning the printing infill percentage were analysed experimentally by measuring depth dose profiles and superficial dose distribution with Gafchromic EBT3 films (International Specialty Products, Wayne, NJ). Dose distributions were compared to those obtained with a commercial superficial applicator. Measured printing accuracy was within 0.5mm. Dose attenuation was not sensitive to the density of the material. Surface dose distribution comparison of the 3D printed flat applicators with respect to the commercial superficial applicator showed an overall passing rate greater than 94% for gamma analysis with 3% dose difference criteria, 3mm distance-to-agreement criteria and 10% dose threshold. Low-cost 3D printers are a promising solution for the customization of the HDR brachytherapy applicators. However, further assessment of 3D printing techniques and regulatory materials approval are required for clinical application. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

    Science.gov (United States)

    Fournier, P.; Crosbie, J. C.; Cornelius, I.; Berkvens, P.; Donzelli, M.; Clavel, A. H.; Rosenfeld, A. B.; Petasecca, M.; Lerch, M. L. F.; Bräuer-Krisch, E.

    2016-07-01

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) in Grenoble, France. MRT exploits the dose volume effect that is made possible through the spatial fractionation of the high dose rate synchrotron-generated x-ray beam into an array of microbeams. As an important step towards the development of a dosimetry protocol for MRT, we have applied the International Atomic Energy Agency’s TRS 398 absorbed dose-to-water protocol to the synchrotron x-ray beam in the case of the broad beam irradiation geometry (i.e. prior to spatial fractionation into microbeams). The very high dose rates observed here mean the ion recombination correction factor, k s , is the most challenging to quantify of all the necessary corrections to apply for ionization chamber based absolute dosimetry. In the course of this study, we have developed a new method, the so called ‘current ramping’ method, to determine k s for the specific irradiation and filtering conditions typically utilized throughout the development of MRT. Using the new approach we deduced an ion recombination correction factor of 1.047 for the maximum ESRF storage ring current (200 mA) under typical beam spectral filtering conditions in MRT. MRT trials are currently underway with veterinary patients at the ESRF that require additional filtering, and we have estimated a correction factor of 1.025 for these filtration conditions for the same ESRF storage ring current. The protocol described herein provides reference dosimetry data for the associated Treatment Planning System utilized in the current veterinary trials and anticipated future human clinical trials.

  9. Effect of radiation dose-rate on hematopoietic cell engraftment in adult zebrafish.

    Directory of Open Access Journals (Sweden)

    Tiffany J Glass

    Full Text Available Although exceptionally high radiation dose-rates are currently attaining clinical feasibility, there have been relatively few studies reporting the biological consequences of these dose-rates in hematopoietic cell transplant (HCT. In zebrafish models of HCT, preconditioning before transplant is typically achieved through radiation alone. We report the comparison of outcomes in adult zebrafish irradiated with 20 Gy at either 25 or 800 cGy/min in the context of experimental HCT. In non-transplanted irradiated fish we observed no substantial differences between dose-rate groups as assessed by fish mortality, cell death in the kidney, endogenous hematopoietic reconstitution, or gene expression levels of p53 and ddb2 (damage-specific DNA binding protein 2 in the kidney. However, following HCT, recipients conditioned with the higher dose rate showed significantly improved donor-derived engraftment at 9 days post transplant (p ≤ 0.0001, and improved engraftment persisted at 31 days post transplant. Analysis for sdf-1a expression, as well as transplant of hematopoietic cells from cxcr4b -/- zebrafish, (odysseus, cumulatively suggest that the sdf-1a/cxcr4b axis is not required of donor-derived cells for the observed dose-rate effect on engraftment. Overall, the adult zebrafish model of HCT indicates that exceptionally high radiation dose-rates can impact HCT outcome, and offers a new system for radiobiological and mechanistic interrogation of this phenomenon. Key words: Radiation dose rate, Total Marrow Irradiation (TMI, Total body irradiation (TBI, SDF-1, Zebrafish, hematopoietic cell transplant.

  10. Effects of stimulus level and rate on psychophysical thresholds for interleaved pulse trains in cochlear implants.

    Science.gov (United States)

    Hughes, Michelle L; Goehring, Jenny L; Baudhuin, Jacquelyn L; Schmid, Kendra K

    2016-10-01

    This study examined channel interactions using interleaved pulse trains to assess masking and potential facilitative effects in cochlear-implant recipients using clinically relevant stimuli. Psychophysical thresholds were measured for two adjacent mid-array electrodes; one served as the masker and the other as the probe. Two rates representative of those found in present-day strategies were tested: 1700 and 3400 pulses per second per channel. Four masker levels ranging from sub-threshold to loud-but-comfortable were tested. It was hypothesized that low-level maskers would produce facilitative effects, shifting to masking effects at high levels, and that faster rates would yield smaller masking effects due to greater stochastic neural firing patterns. Twenty-nine ears with Cochlear or Advanced Bionics devices were tested. High-level maskers produced more masking than low-level maskers, as expected. Facilitation was not observed for sub-threshold or threshold-level maskers in most cases. High masker levels yielded reduced probe thresholds for two Advanced Bionics subjects. This was partly eliminated with a longer temporal offset between each masker-probe pulse pair, as was used with Cochlear subjects. These findings support the use of temporal gaps between stimulation of subsequent electrodes to reduce channel interactions.

  11. Effect of fractionation and rate of radiation dose on human leukemic cells, HL-60

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, J.G.; Song, C.W.; Kim, T.H.; Levitt, S.H.

    1985-03-01

    The capacity of HL-60 cells, human acute promyelocytic leukemic cells established in culture, to repair sublethal radiation damage was estimated from the response of the cells to fractionated irradiation or to a single irradiation at difference dose rates. After exposure of cells to a single dose of X rays at a dose rate of 78 rad/min, the survival curve was characterized by n = 2.5, D/sub q/ = 80 rad, and D/sub 0/ = 83.2 rad. Split-dose studies demonstrated that the cells were able to repair a substantial portion of sublethal radiation damage in 2 hr. The response of the cells to irradiation at different dose rates decreased with a decrease in the dose rates, which could be attributed to repair of sublethal radiation damage. The possibility that some of the malignant hemopoietic cells, if not all, may possess a substantial capacity to repair sublethal radiation damage should not be underestimated in planning total-body irradiation followed by bone marrow transplantation.

  12. Effects of cochlear-implant pulse rate and inter-channel timing on channel interactions and thresholds

    Science.gov (United States)

    Middlebrooks, John C.

    2004-07-01

    Interactions among the multiple channels of a cochlear prosthesis limit the number of channels of information that can be transmitted to the brain. This study explored the influence on channel interactions of electrical pulse rates and temporal offsets between channels. Anesthetized guinea pigs were implanted with 2-channel scala-tympani electrode arrays, and spike activity was recorded from the auditory cortex. Channel interactions were quantified as the reduction of the threshold for pulse-train stimulation of the apical channel by sub-threshold stimulation of the basal channel. Pulse rates were 254 or 4069 pulses per second (pps) per channel. Maximum threshold reductions averaged 9.6 dB when channels were stimulated simultaneously. Among nonsimultaneous conditions, threshold reductions at the 254-pps rate were entirely eliminated by a 1966-μs inter-channel offset. When offsets were only 41 to 123 μs, however, maximum threshold shifts averaged 3.1 dB, which was comparable to the dynamic ranges of cortical neurons in this experimental preparation. Threshold reductions at 4069 pps averaged up to 1.3 dB greater than at 254 pps, which raises some concern in regard to high-pulse-rate speech processors. Thresholds for various paired-pulse stimuli, pulse rates, and pulse-train durations were measured to test possible mechanisms of temporal integration.

  13. A conversion formula for comparing pulse oximeter desaturation rates obtained with different averaging times.

    Directory of Open Access Journals (Sweden)

    Jan Vagedes

    Full Text Available OBJECTIVE: The number of desaturations determined in recordings of pulse oximeter saturation (SpO2 primarily depends on the time over which values are averaged. As the averaging time in pulse oximeters is not standardized, it varies considerably between centers. To make SpO2 data comparable, it is thus desirable to have a formula that allows conversion between desaturation rates obtained using different averaging times for various desaturation levels and minimal durations. METHODS: Oxygen saturation was measured for 170 hours in 12 preterm infants with a mean number of 65 desaturations <90% per hour of arbitrary duration by using a pulse oximeter in a 2-4 s averaging mode. Using 7 different averaging times between 3 and 16 seconds, the raw red-to-infrared data were reprocessed to determine the number of desaturations (D. The whole procedure was carried out for 7 different minimal desaturation durations (≥ 1, ≥ 5, ≥ 10, ≥ 15, ≥ 20, ≥ 25, ≥ 30 s below SpO2 threshold values of 80%, 85% or 90% to finally reach a conversion formula. The formula was validated by splitting the infants into two groups of six children each and using one group each as a training set and the other one as a test set. RESULTS: Based on the linear relationship found between the logarithm of the desaturation rate and the logarithm of the averaging time, the conversion formula is: D2 = D1 (T2/T1(c, where D2 is the desaturation rate for the desired averaging time T2, and D1 is the desaturation rate for the original averaging time T1, with the exponent c depending on the desaturation threshold and the minimal desaturation duration. The median error when applying this formula was 2.6%. CONCLUSION: This formula enables the conversion of desaturation rates between different averaging times for various desaturation thresholds and minimal desaturation durations.

  14. Extension of CASCADE.04 to estimate neutron fluence and dose rates and its validation

    Indian Academy of Sciences (India)

    H Kumawat; V Kumar; P Srinivasan

    2009-03-01

    Capability to compute neutron dose rate is introduced for the first time in the new version of the CASCADE.04 code. Two different methods, `track length estimator' and `collision estimator' are adapted for the estimation of neutron fluence rate needed to calculate the ambient dose rate. For the validation of the methods, neutron dose rates are experimentally measured at different locations of a 5Ci Am–Be source, shielded in Howitzer-type system and these results are compared with those estimated using (i) modified CASCADE.04.d and (ii) MCNP4A codes and it is found that the agreement is good. The paper presents details of modification and results of the comparative study.

  15. UWB multi-pulse position modulation for high data-rate wireless application

    Institute of Scientific and Technical Information of China (English)

    WANG Ye-qiu; LU Ying-hua; ZHANG Hong-xin; HE Peng-fei; ZHANG Li-kun

    2006-01-01

    A new ultra-wide band (UWB) modulation scheme called L-ary ultra-wide band time hopping multi-pulse position modulation (UWB-TH-MPPM) is proposed for high data-rate wireless application, which can provide better communication performance. The constant weight code is introduced to construct the MPPM signal and the comparison between MPPM and single pulse position modulation (SPPM) is done in three aspects, namely, power efficiency, bandwidth efficiency, and probability of symbol error, respectively. The theoretical analysis and the numerical results show that when the constant weight code is appropriately chosen, MPPM can achieve lower probability of symbol error and higher power efficiency than SPPM at the cost of more bandwidth under the same condition.The proposed MPPM can be a good candidate in UWB system design.

  16. Predictions of Radionuclide Dose Rates from Sellafield Discharges using a Compartmental Model

    Energy Technology Data Exchange (ETDEWEB)

    McCubbin, D.; Leonard, K.S.; Gurbutt, P.A.; Round, G.D

    1998-07-01

    A multi-compartmental model (MIRMAID) of the Irish Sea has been used to predict radionuclide dose rates to the public, via seafood consumption pathways. Radionuclides originate from the authorised discharge of low level liquid effluent from the BNF plc nuclear reprocessing plant at Sellafield. The model has been used to predict combined annual doses, the contribution of dose from individual radionuclides and to discriminate dose between present day and historic discharges. An assessment has been carried out to determine the sensitivity of the predictions to changes in various model parameters. The predicted dose to the critical group from seafood consumption in 1995 ranged from 37-96 {mu}Sv of which the majority originated from current discharges. The contribution from {sup 99}Tc was predicted to have increased from 0.2% in 1993 up to 20% in 1995. The predicted contribution of Pu and Am from historic discharges is underestimated in the model. (author)

  17. Radiation dose rate map interpolation in nuclear plants using neural networks and virtual reality techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mol, Antonio Carlos A., E-mail: mol@ien.gov.br [Comissao Nacional de Energia Nuclear, Instituto de Engenharia Nuclear Rua Helio de Almeida, 75, Ilha do Fundao, P.O. Box 68550, 21941-906 Rio de Janeiro, RJ (Brazil); Instituto Nacional de Ciencia e Tecnologia de Reatores Nucleares Inovadores/CNPq (Brazil); Pereira, Claudio Marcio N.A., E-mail: cmnap@ien.gov.br [Comissao Nacional de Energia Nuclear, Instituto de Engenharia Nuclear Rua Helio de Almeida, 75, Ilha do Fundao, P.O. Box 68550, 21941-906 Rio de Janeiro, RJ (Brazil); Instituto Nacional de Ciencia e Tecnologia de Reatores Nucleares Inovadores/CNPq (Brazil); Freitas, Victor Goncalves G. [Universidade Federal do Rio de Janeiro, Programa de Engenharia Nuclear, Rio de Janeiro, RJ (Brazil); Jorge, Carlos Alexandre F., E-mail: calexandre@ien.gov.br [Comissao Nacional de Energia Nuclear, Instituto de Engenharia Nuclear Rua Helio de Almeida, 75, Ilha do Fundao, P.O. Box 68550, 21941-906 Rio de Janeiro, RJ (Brazil)

    2011-02-15

    This paper reports the most recent development results of a simulation tool for assessment of radiation dose exposition by nuclear plant's personnel, using artificial intelligence and virtual reality technologies. The main purpose of this tool is to support training of nuclear plants' personnel, to optimize working tasks for minimisation of received dose. A finer grid of measurement points was considered within the nuclear plant's room, for different power operating conditions. Further, an intelligent system was developed, based on neural networks, to interpolate dose rate values among measured points. The intelligent dose prediction system is thus able to improve the simulation of dose received by personnel. This work describes the improvements implemented in this simulation tool.

  18. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Laspas, Fotios; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John (CT and MRI Dept., Hygeia Hospital, Athens (Greece)), e-mail: fotisdimi@yahoo.gr; Tsantioti, Dimitra (Statistician, Hygeia Hospital, Athens (Greece))

    2011-04-15

    Background: Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose: To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods: Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results: Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR =65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion: Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure

  19. Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E.; Zhen Heming; Tome, Wolfgang A. [Canis Lupus LLC and Department of Human Oncology, University of Wisconsin, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Departments of Human Oncology, Medical Physics, and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-02-15

    Purpose: The purpose of this work is to determine the statistical correlation between per-beam, planar IMRT QA passing rates and several clinically relevant, anatomy-based dose errors for per-patient IMRT QA. The intent is to assess the predictive power of a common conventional IMRT QA performance metric, the Gamma passing rate per beam. Methods: Ninety-six unique data sets were created by inducing four types of dose errors in 24 clinical head and neck IMRT plans, each planned with 6 MV Varian 120-leaf MLC linear accelerators using a commercial treatment planning system and step-and-shoot delivery. The error-free beams/plans were used as ''simulated measurements'' (for generating the IMRT QA dose planes and the anatomy dose metrics) to compare to the corresponding data calculated by the error-induced plans. The degree of the induced errors was tuned to mimic IMRT QA passing rates that are commonly achieved using conventional methods. Results: Analysis of clinical metrics (parotid mean doses, spinal cord max and D1cc, CTV D95, and larynx mean) vs IMRT QA Gamma analysis (3%/3 mm, 2/2, 1/1) showed that in all cases, there were only weak to moderate correlations (range of Pearson's r-values: -0.295 to 0.653). Moreover, the moderate correlations actually had positive Pearson's r-values (i.e., clinically relevant metric differences increased with increasing IMRT QA passing rate), indicating that some of the largest anatomy-based dose differences occurred in the cases of high IMRT QA passing rates, which may be called ''false negatives.'' The results also show numerous instances of false positives or cases where low IMRT QA passing rates do not imply large errors in anatomy dose metrics. In none of the cases was there correlation consistent with high predictive power of planar IMRT passing rates, i.e., in none of the cases did high IMRT QA Gamma passing rates predict low errors in anatomy dose metrics or vice versa

  20. The role of dose rate in radiation cancer risk: evaluating the effect of dose rate at the molecular, cellular and tissue levels using key events in critical pathways following exposure to low LET radiation.

    Science.gov (United States)

    Brooks, Antone L; Hoel, David G; Preston, R Julian

    2016-08-01

    This review evaluates the role of dose rate on cell and molecular responses. It focuses on the influence of dose rate on key events in critical pathways in the development of cancer. This approach is similar to that used by the U.S. EPA and others to evaluate risk from chemicals. It provides a mechanistic method to account for the influence of the dose rate from low-LET radiation, especially in the low-dose region on cancer risk assessment. Molecular, cellular, and tissues changes are observed in many key events and change as a function of dose rate. The magnitude and direction of change can be used to help establish an appropriate dose rate effectiveness factor (DREF). Extensive data on key events suggest that exposure to low dose-rates are less effective in producing changes than high dose rates. Most of these data at the molecular and cellular level support a large (2-30) DREF. In addition, some evidence suggests that doses delivered at a low dose rate decrease damage to levels below that observed in the controls. However, there are some data human and mechanistic data that support a dose-rate effectiveness factor of 1. In summary, a review of the available molecular, cellular and tissue data indicates that not only is dose rate an important variable in understanding radiation risk but it also supports the selection of a DREF greater than one as currently recommended by ICRP ( 2007 ) and BEIR VII (NRC/NAS 2006 ).

  1. Dose-rate mapping and search of radioactive sources in Estonia

    Energy Technology Data Exchange (ETDEWEB)

    Ylaetalo, S.; Karvonen, J.; Ilander, T.; Honkamaa, T.; Toivonen, H.

    1996-12-01

    The Estonian Ministry of Environment and the Finnish Centre for Radiation and Nuclear Safety (STUK) agreed in 1995 on a radiation mapping project in Estonia. The country was searched to find potential man-made radioactive sources. Another goal of the project was to produce a background dose-rate map over the whole country. The measurements provided an excellent opportunity to test new in-field measuring systems that are useful in a nuclear disaster. The basic idea was to monitor road sides, cities, domestic waste storage places and former military or rocket bases from a moving vehicle by measuring gamma spectrum and dose rate. The measurements were carried out using vehicle installed systems consisting of a pressurised ionisation chamber (PIC) in 1995 and a combination of a scintillation spectrometer (NaI(TI)) and Geiger-Mueller-counter (GM) in 1996. All systems utilised GPS-satellite navigation signals to relate the measured dose rates and gamma-spectra to current geographical location. The data were recorded for further computer analysis. The dose rate varied usually between 0.03-0.17 {mu}Sv/h in the whole country, excluding a few nuclear material storage places (in Saku and in Sillamae). Enhanced dose rates of natural origin (0.17-0.5 {mu}Sv/h) were measured near granite statues, buildings and bridges. No radioactive sources were found on road sides or in towns or villages. (orig.) (14 refs.).

  2. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  3. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer*

    Science.gov (United States)

    Pellizzon, Antônio Cássio Assis

    2016-01-01

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. PMID:27403021

  4. Current topics in the treatment of prostate cancer with low-dose-rate brachytherapy.

    Science.gov (United States)

    Stock, Richard G; Stone, Nelson N

    2010-02-01

    The treatment of prostate cancer with low dose rate prostate brachytherapy has grown rapidly in the last 20 years. Outcome analyses performed in this period have enriched understanding of this modality. This article focuses on the development of a real-time ultrasound-guided implant technique, the importance of radiation dose, trimodality treatment of high-risk disease, long-term treatment outcomes, and treatment-associated morbidity.

  5. Comparative dosimetry of GammaMed Plus high-dose rate 192 Ir brachytherapy source

    Directory of Open Access Journals (Sweden)

    Patel N

    2010-01-01

    Full Text Available The comparative dosimetry of GammaMed (GM Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc chamber to derive the radial dose function (r = 0.8 to 20.0 cm and anisotropy function (r = 5.0 cm with polar angle from 10° to 170°. The nonuniformity correction factor for 0.1-cc chamber was applied for in-water measurements at shorter distances from the source. The EGSnrc code was used to derive the dose rate constant (L, radial dose function g L (r and anisotropy function F(r, q of GM Plus source. The dosimetric data derived using EGSnrc code in our study were in very good agreement relative to published data for GM Plus source. The radial dose function up to 12 cm derived from measured dose using 0.1-cc chamber was in agreement within ±3% of data derived by the simulation study.

  6. Measured dose rate constant from oncology patients administered 18F for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Quinn, Brian; Holahan, Brian; Aime, Jean; Humm, John; St Germain, Jean; Dauer, Lawrence T. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States); Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States) and Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States); Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States) and Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10065 (United States)

    2012-10-15

    Purpose: Patient exposure rate measurements verify published patient dose rate data and characterize dose rates near 2-18-fluorodeoxyglucose ({sup 18}F-FDG) patients. A specific dose rate constant based on patient exposure rate measurements is a convenient quantity that can be applied to the desired distance, injection activity, and time postinjection to obtain an accurate calculation of cumulative external radiation dose. This study reports exposure rates measured at various locations near positron emission tomography (PET) {sup 18}F-FDG patients prior to PET scanning. These measurements are normalized for the amount of administered activity, measurement distance, and time postinjection and are compared with other published data. Methods: Exposure rates were measured using a calibrated ionization chamber at various body locations from 152 adult oncology patients postvoid after a mean uptake time of 76 min following injection with a mean activity of 490 MBq {sup 18}F-FDG. Data were obtained at nine measurement locations for each patient: three near the head, four near the chest, and two near the feet. Results: On contact with, 30 cm superior to and 30 cm lateral to the head, the mean (75th percentile) dose rates per unit injected activity at 60 min postinjection were 0.482 (0.511), 0.135 (0.155), and 0.193 (0.223) {mu}Sv/MBq h, respectively. On contact with, 30 cm anterior to, 30 cm lateral to and 1 m anterior to the chest, the mean (75th percentile) dose rates per unit injected activity at 60 min postinjection were 0.623 (0.709), 0.254 (0.283), 0.190 (0.218), and 0.067 (0.081) {mu}Sv/MBq h respectively. 30 cm inferior and 30 cm lateral to the feet, the mean (75th percentile) dose rates per unit injected activity at 60 min postinjection were 0.024 (0.022) and 0.039 (0.044) {mu}Sv/MBq h, respectively. Conclusions: The measurements for this study support the use of 0.092 {mu}Sv m{sup 2}/MBq h as a reasonable representation of the dose rate anterior from the chest of

  7. Effect of pulsed corona discharge voltage and feed gas flow rate on dissolved ozone concentration

    Energy Technology Data Exchange (ETDEWEB)

    Prasetyaningrum, A., E-mail: ajiprasetyaningrum@gmail.com; Ratnawati,; Jos, B. [Department of Chemical Engineering, Faculty of Engineering, Diponegoro University Jl. Prof. H. Soedarto Tembalang, Semarang, Central Java, Indonesia, 50276 (Indonesia)

    2015-12-29

    Ozonization is one of the methods extensively used for water purification and degradation of organic materials. Ozone (O{sub 3}) is recognized as a powerful oxidizing agent. Due to its strong oxidability and better environmental friendless, ozone increasing being used in domestic and industrial applications. Current technology in ozone production utilizes several techniques (corona discharge, ultra violet radiation and electrolysis). This experiment aimed to evaluating effect of voltage and gas flow rate on ozone production with corona discharge. The system consists of two net-type stainless steel electrode placed in a dielectric barrier. Three pulsed voltage (20, 30, 40 KV) and flow rate (5, 10, 15 L/min) were prepare for operation variable at high frequency (3.7 kHz) with AC pulsed power supply. The dissolved ozone concentration depends on the applied high-voltage level, gas flow rate and the discharge exposure duration. The ozone concentration increases with decreasing gas flow rate. Dissolved ozone concentrations greater than 200 ppm can be obtained with a minimum voltage 40 kV.

  8. Iron Oxide Nanoparticle Agglomeration Influences Dose-Rates and Modulates Oxidative Stress Mediated Dose-Response Profiles In Vitro

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Gaurav; Kodali, Vamsi K.; Gaffrey, Matthew J.; Wang, Wei; Minard, Kevin R.; Karin, Norman J.; Teeguarden, Justin G.; Thrall, Brian D.

    2013-07-31

    Spontaneous agglomeration of engineered nanoparticles (ENPs) is a common problem in cell culture media which can confound interpretation of in vitro nanotoxicity studies. The authors created stable agglomerates of iron oxide nanoparticles (IONPs) in conventional culture medium, which varied in hydrodynamic size (276 nm-1.5 μm) but were composed of identical primary particles with similar surface potentials and protein coatings. Studies using C10 lung epithelial cells show that the dose rate effects of agglomeration can be substantial, varying by over an order of magnitude difference in cellular dose in some cases. Quantification by magnetic particle detection showed that small agglomerates of carboxylated IONPs induced greater cytotoxicity and redox-regulated gene expression when compared with large agglomerates on an equivalent total cellular IONP mass dose basis, whereas agglomerates of amine-modified IONPs failed to induce cytotoxicity or redox-regulated gene expression despite delivery of similar cellular doses. Dosimetry modelling and experimental measurements reveal that on a delivered surface area basis, large and small agglomerates of carboxylated IONPs have similar inherent potency for the generation of ROS, induction of stress-related genes and eventual cytotoxicity. The results suggest that reactive moieties on the agglomerate surface are more efficient in catalysing cellular ROS production than molecules buried within the agglomerate core. Because of the dynamic, size and density-dependent nature of ENP delivery to cells in vitro, the biological consequences of agglomeration are not discernible from static measures of exposure concentration (μg/ml) alone, highlighting the central importance of integrated physical characterisation and quantitative dosimetry for in vitro studies. The combined experimental and computational approach provides a quantitative framework for evaluating relationships between the biocompatibility of nanoparticles and their

  9. The MapCHECK Measurement Uncertainty function and its effect on planar dose pass rates.

    Science.gov (United States)

    Bailey, Daniel W; Spaans, Jason D; Kumaraswamy, Lalith K; Podgorsak, Matthew B

    2016-03-08

    Our study aimed to quantify the effect of the Measurement Uncertainty function on planar dosimetry pass rates, as measured and analyzed with the Sun Nuclear Corporation MapCHECK 2 array and its associated software. This optional function is toggled in the program preferences of the software (though turned on by default upon installation), and automatically increases the dose difference tolerance defined by the user for each planar dose comparison. Dose planes from 109 static-gantry IMRT fields and 40 VMAT arcs, of varying modulation complexity, were measured at 5 cm water-equivalent depth in the MapCHECK 2 diode array, and respective calculated dose planes were exported from a commercial treatment planning system. Planar dose comparison pass rates were calculated within the Sun Nuclear Corporation analytic software using a number of calculation parameters, including Measurement Uncertainty on and off. By varying the percent difference (%Diff) criterion for similar analyses performed with Measurement Uncertainty turned off, an effective %Diff criterion was defined for each field/arc corresponding to the pass rate achieved with Measurement Uncertainty turned on. On average, the Measurement Uncertainty function increases the user-defined %Diff criterion by 0.8%-1.1% for 3%/3 mm analysis, depending on plan type and calculation technique (corresponding to an average change in pass rate of 1.0%-3.5%, and a maximum change of 8.7%). At the 2%/2 mm level, the Measurement Uncertainty function increases the user-defined %Diff criterion by 0.7%-1.2% on average, again depending on plan type and calculation technique (corresponding to an average change in pass rate of 3.5%-8.1%, and a maximum change of 14.2%). The largest increases in pass rate due to the Measurement Uncertainty function are generally seen with poorly matched planar dose comparisons, while the function has a notably smaller effect as pass rates approach 100%. The Measurement Uncertainty function, then, may

  10. Efficacy of a Low Dose of Estrogen on Antioxidant Defenses and Heart Rate Variability

    Directory of Open Access Journals (Sweden)

    Cristina Campos

    2014-01-01

    Full Text Available This study tested whether a low dose (40% less than the pharmacological dose of 17-β estradiol would be as effective as the pharmacological dose to improve cardiovascular parameters and decrease cardiac oxidative stress. Female Wistar rats (n=9/group were divided in three groups: (1 ovariectomized (Ovx, (2 ovariectomized animals treated for 21 days with low dose (LE; 0.2 mg, and (3 high dose (HE; 0.5 mg 17-β estradiol subcutaneously. Hemodynamic assessment and spectral analysis for evaluation of autonomic nervous system regulation were performed. Myocardial superoxide dismutase (SOD and catalase (CAT activities, redox ratio (GSH/GSSG, total radical-trapping antioxidant potential (TRAP, hydrogen peroxide, and superoxide anion concentrations were measured. HE and LE groups exhibited an improvement in hemodynamic function and heart rate variability. These changes were associated with an increase in the TRAP, GSH/GSSG, SOD, and CAT. A decrease in hydrogen peroxide and superoxide anion was also observed in the treated estrogen groups as compared to the Ovx group. Our results indicate that a low dose of estrogen is just as effective as a high dose into promoting cardiovascular function and reducing oxidative stress, thereby supporting the approach of using low dose of estrogen in clinical settings to minimize the risks associated with estrogen therapy.

  11. Preliminary survey of outdoor gamma dose rates in Lesvos Island (Greece).

    Science.gov (United States)

    Petalas, Anastasios B; Vogiannis, Efstratios; Nikolopoulos, Dimitrios; Halvadakis, Constantinos P

    2005-01-01

    This study reports the first attempt to record the radioactive background due to gamma radiation in Lesvos Island (Greece). The study reports the results from 335 outdoor total gamma effective dose rate measurements conducted using GPS navigation and a Geiger-Muller detector (Bicron, Micro Sievert) on the whole surface of the island together with a digital map produced by appropriate mapping GIS programme. The study also reports the measurements of outdoor gamma dose rates due to the 238U, 232Th and 40K radionuclides as estimated via in situ gamma-ray spectrometry measurements performed at 26 sites using a 3 x 3 inch NaI (thallium activated) portable detector. The results from the outdoor total gamma effective dose rates range between 0.0023 and 0.28 microSv h(-1). The highest outdoor total gamma effective dose rates (0.013-0.28 microSv h(-1)) were detected in the northeastern part of the island and the intermediate rates (0.066-0.13 microSv h(-1)) in the central region. The outdoor gamma dose rates due to 238U, 232Th and 40K radionuclides range between 1.7 +/- 0.8 and 154 +/- 7 nGy h(-1) with an average of 86 +/- 6 nGy h(-1). The average contribution of each of the examined radionuclides (238U, 232Th and 40K) to the total gamma dose rate was found to be equal to 12 +/- 4% for 238U, 58 +/- 6% for 232Th and 29 +/- 7% for 40K, respectively.

  12. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, R.; McCarty, M. [Div. of Radiology, South Cleveland Hospital, South Tees Acute Hospitals NHS Trust, Marton Road, Middlesbrough, Cleveland (United Kingdom); McCallum, H.M. [Regional Medical Physics Dept., South Cleveland Hospital, Middlesbrough (United Kingdom); Montgomery, R. [Dept. of Orthopaedics, South Tees Hospitals NITS Trust, Middlesbrough (United Kingdom); Aszkenasy, M. [Tees and North East Yorkshire NHS Trust, West Lane Hospital, Middlesbrough (United Kingdom)

    2001-05-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  13. Shutdown dose rate assessment with the Advanced D1S method: Development, applications and validation

    Energy Technology Data Exchange (ETDEWEB)

    Villari, R., E-mail: rosaria.villari@enea.it [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Fischer, U. [Karlsruhe Institute of Technology KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Moro, F. [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Pereslavtsev, P. [Karlsruhe Institute of Technology KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Petrizzi, L. [European Commission, DG Research and Innovation K5, CDMA 00/030, B-1049 Brussels (Belgium); Podda, S. [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Serikov, A. [Karlsruhe Institute of Technology KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-10-15

    Highlights: Development of Advanced-D1S for shutdown dose rate calculations; Recent applications of the tool to tokamaks; Summary of the results of benchmarking with measurements and R2S calculations; Limitations and further development. Abstract: The present paper addresses the recent developments and applications of Advanced-D1S to the calculations of shutdown dose rate in tokamak devices. Results of benchmarking with measurements and Rigorous 2-Step (R2S) calculations are summarized and discussed as well as limitations and further developments. The outcomes confirm the essential role of the Advanced-D1S methodology and the evidence for its complementary use with the R2Smesh approach for the reliable assessment of shutdown dose rates and related statistical uncertainties in present and future fusion devices.

  14. Correlation analysis of gamma dose rate from natural radiation in the test field

    Directory of Open Access Journals (Sweden)

    Avdic Senada

    2016-01-01

    Full Text Available This paper deals with correlation analysis of gamma dose rate measured in the test field with the five distinctive soil samples from a few minefields in Federation of Bosnia and Herzegovina. The measurements of ambient dose equivalent rate, due to radionuclides present in each of the soil samples, were performed by the RADIAGEMTM 2000 portable survey meter, placed on the ground and 1m above the ground. The gamma spectrometric analysis of the same soil samples was carried out by GAMMA-RAD5 spectrometer. This study showed that there is a high correlation between the absorbed dose rate evaluated from soil radioactivity and the corresponding results obtained by the survey meter placed on the ground. Correlation analysis indicated that the survey meter, due to its narrow energy range, is not suitable for the examination of cosmic radiation contribution.

  15. Gamma Radiation Measurements and Dose Rates in Commonly Used Building Materials in Cyprus

    CERN Document Server

    Michael, F; Parpottas, Y

    2010-01-01

    A first comprehensive study is presented on radioactivity concentrations and dose rates in 87 commonly used materials, manufactured or imported in Cyprus, for building purposes. The natural radioactivity of K-40, Th-232, U-238 and Ra-226 is determined using high-resolution gamma ray spectroscopy. The respective dose rates and the associated radiological effect indices are also calculated. A comparison of the measured specific activity values with the corresponding world average values shows that most of them are below the world average activity values. The annual indoor effective dose rates received by an individual from three measured imported granites and four measured imported ceramics are found to be higher than the world upper limit value of 1 mSv y-1. Hence, these materials should have a restricted use according to their corresponding calculated activity concentration index values and the related EC 1999 guidelines.

  16. The enhanced low dose rate sensitivity of a linear voltage regulator with different biases

    Institute of Scientific and Technical Information of China (English)

    Wang Yiyuan; Lu Wu; Ren Diyuan; Guo Qi; Yu Xuefeng; Gao Bo

    2011-01-01

    A linear voltage regulator was irradiated by 60Co γ at high and low dose rates with two bias conditions to investigate the dose rate effect.The devices exhibit enhanced low dose rate sensitivity (ELDRS) under both biases.Comparing the enhancement factors between zero and working biases,it was found that the ELDRS is more severe under zero bias conditions.This confirms that the ELDRS is related to the low electric field in a bipolar structure.The reasons for the change in the line regulation and the maximum drive current were analyzed by combining the principle of linear voltage regulator with irradiation response of the transistors and error amplifier in the regulator.This may be helpful for designing radiation hardened devices.

  17. Generation of low jitter and discrete tunable dual-wavelength optical pulses at arbitrary repetition rates

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ming-jiang; WANG Yun-cai

    2006-01-01

    A novel and simple method to generate low timing jitter and discrete tunable dual-wavelength optical pulses at arbitrary repetition rates is demonstrated in this paper.Two multiple quantum wells distributed feedback laser diodes,were used as the external seeding sources to inject the external photons into a gain-switched Fabry-Perot laser diode.The output wavelengths can be tuned discretely to coincide with any two lasing modes in the gain spectra range of the Fabry-Perot Laser diode,and the output side mode suppression ratio was better than 25 dB.Moreover,the timing jitter of optical pulses was reduced from 1.89 ps to 0.83 ps.It was empirically found that the lowest timing jitter operation occurred when the injected light wavelength is 0.2-0.3 nm shorter than the locked mode of the Fabry-Perot laser diode.To our knowledge,this is the first report of using two DFB laser diodes as a seeding source to reduce pulses jitter and select lasing dual-wavelength simultaneously.

  18. Model of radiation-induced gain degradation of NPN bipolar junction transistor at different dose rates

    Science.gov (United States)

    Qifeng, Zhao; Yiqi, Zhuang; Junlin, Bao; Wei, Hu

    2015-06-01

    Ionizing-radiation-induced current gain degradation in NPN bipolar junction transistors is due to an increase in base current as a result of recombination at the surface of the device. A model is presented which identifies the physical mechanism responsible for current gain degradation. The increase in surface recombination velocity due to interface states results in an increase in base current. Besides, changing the surface potential along the base surface induced by the oxide-trapped charges can also lead to an increased base current. By combining the production mechanisms of oxide-trapped charges and interface states, this model can explain the fact that the current gain degradation is more severe at a low dose rate than at a high dose rate. The radiations were performed in a Co60 source up to a total dose of 70 krad(Si). The low dose rate was 0.1 rad(Si)/s and the high dose rate was 10 rad(Si)/s. The model accords well with the experimental results. Project supported by the National Natural Science Foundation of China (Nos. 61076101, 61204092).

  19. Degradation and annealing studies on gamma rays irradiated COTS PPD CISs at different dose rates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zujun, E-mail: wangzujun@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Ma, Yingwu [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Xiangtan, 411105 Hunan (China); Xue, Yuan; He, Baoping; Yao, Zhibin; Huang, Shaoyan; Liu, Minbo; Sheng, Jiangkun [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China)

    2016-06-01

    The degradation and annealing studies on Colbalt-60 gamma-rays irradiated commercial-off-the-shelf (COTS) pinned photodiode (PPD) CMOS image sensors (CISs) at the various dose rates are presented. The irradiation experiments of COTS PPD CISs are carried out at 0.3, 3.0 and 30.0 rad(Si)/s. The COTS PPD CISs are manufactured using a standard 0.18-μm CMOS technology with four-transistor pixel PPD architecture. The behavior of the tested CISs shows a remarkable degradation after irradiation and differs in the dose rates. The dark current, dark signal non-uniformity (DSNU), random noise, saturation output, signal to noise ratio (SNR), and dynamic range (DR) versus the total ionizing dose (TID) at the various dose rates are investigated. The tendency of dark current, DSNU, and random noise increase and saturation output, SNR, and DR to decrease at 3.0 rad(Si)/s are far greater than those at 0.3 and 30.0 rad(Si)/s. The damage mechanisms caused by TID irradiation at the various dose rates are also analyzed. The annealing tests are carried out at room temperature with unbiased conditions after irradiation.

  20. Measurements of pulse rate using long-range imaging photoplethysmography and sunlight illumination outdoors

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.

    2017-02-01

    Imaging photoplethysmography, a method using imagers to record absorption variations caused by microvascular blood volume pulsations, shows promise as a non-contact cardiovascular sensing technology. The first long-range imaging photoplethysmography measurements at distances of 25, 50, and 100 meters from the participant was recently demonstrated. Degraded signal quality was observed with increasing imager-to-subject distances. The degradation in signal quality was hypothesized to be largely attributable to inadequate light return to the image sensor with increasing lens focal length. To test this hypothesis, a follow-up evaluation with 27 participants was conducted outdoors with natural sunlight illumination resulting in 5-33 times the illumination intensity. Video was recorded from cameras equipped with ultra-telephoto lenses and positioned at distances of 25, 50, 100, and 150 meters. The brighter illumination allowed high-definition video recordings at increased frame rates of 60fps, shorter exposure times, and lower ISO settings, leading to higher quality image formation than the previous indoor evaluation. Results were compared to simultaneous reference measurements from electrocardiography. Compared to the previous indoor study, we observed lower overall error in pulse rate measurement with the same pattern of degradation in signal quality with respect to increasing distance. This effect was corroborated by the signal-to-noise ratio of the blood volume pulse signal which also showed decreasing quality with respect to increasing distance. Finally, a popular chrominance-based method was compared to a blind source separation approach; while comparable in measurement of signal-to-noise ratio, we observed higher overall error in pulse rate measurement using the chrominance method in this data.

  1. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, Heming; Nelms, Benjamin E.; Tome, Wolfgang A. [Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 (United States); Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792 and Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Medical Physics, University of Wisconsin, Madison, Wisconsin 53705 and Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792 (United States)

    2011-10-15

    Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was

  2. Effect of Heart Rate on Arterial Stiffness as Assessed by Pulse Wave Velocity.

    Science.gov (United States)

    Tan, Isabella; Butlin, Mark; Spronck, Bart; Xiao, Huanguang; Avolio, Alberto

    2017-07-24

    Vascular assessment is becoming increasingly important in the diagnosis of cardiovascular diseases. In particular, clinical assessment of arterial stiffness, as measured by pulse wave velocity (PWV), is gaining increased interest due to the recognition of PWV as an influential factor on the prognosis of hypertension as well as being an independent predictor of cardiovascular and all-cause mortality. Whilst age and blood pressure are established as the two major determinants of PWV, the influence of heart rate on PWV measurements remains controversial with conflicting results being observed in both acute and epidemiological studies. In a majority of studies investigating the acute effects of heart rate on PWV, results were confounded by concomitant changes in blood pressure. Observations from epidemiological studies have also failed to converge, with approximately just half of such studies reporting a significant blood-pressure-independent association between heart rate and PWV. Further to the lack of consensus on the effects of heart rate on PWV, the possible mechanisms contributing to observed PWV changes with heart rate have yet to be fully elucidated, although many investigators have attributed heart-rate related changes in arterial stiffness to the viscoelasticity of the arterial wall. With elevated heart rate being an independent prognostic factor of cardiovascular disease and its association with hypertension, the interaction between heart rate and PWV continues to be relevant in assessing cardiovascular risk. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. False alarm rates of three third-generation pulse oximeters in PACU, ICU and IABP patients.

    Science.gov (United States)

    Lutter, Norbert O; Urankar, Sabine; Kroeber, Steffi

    2002-01-01

    The objective of this clinical study was to determine alarm rates--in particular the frequency of false positive alarms--of three third-generation pulse oximeters in the postanesthesia care unit (PACU), the intensive care unit (ICU), and in patients with an intra-aortic balloon pump (IABP): Nellcor Symphony N-3000, a Masimo IVY 2000, and Agilent Viridia CMS 2000. All alarms were classified into technical/physiological and false/correct. 235 consecutive ASA physical status I-IV patients after surgery were included into the study. In the PACU false positive alarms were rare: CMS n = 60, N-3000 n = 60, Masimo n = 87. Bland-Altman testing discovered only negligible differences of alarm rates and dropout times. Out of a total of 728 alarms 67.3% were classified as false positive in ICU-patients: 97 alarms by CMS, 176 by N-3000 and 218 by Masimo SET. If IABP was present, CMS indicated a significant smaller number of false positive alarms (n = 35, 7.2%) when compared to Masimo SET (n = 188, 38.9%) and N-3000 (n = 229, 47.4%), consecutively the majority of false positive alarms (76.2%) can be rated as a result of the interference of IABP. Unless IABP (and to a considerably smaller extent cardiac arrhythmia) is present the pulse oximeters do not differ significantly regarding sensitivity and specificity.

  4. High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

    Science.gov (United States)

    Singh, Uprendra N.; Bai, Yingxin; Yu, Jirong; Petros, Mulugeta; Petzar, Paul J.; Trieu, Bo C.; Lee, Hyung

    2009-01-01

    A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.

  5. Power scaling of supercontinuum seeded megahertz-repetition rate optical parametric chirped pulse amplifiers.

    Science.gov (United States)

    Riedel, R; Stephanides, A; Prandolini, M J; Gronloh, B; Jungbluth, B; Mans, T; Tavella, F

    2014-03-15

    Optical parametric chirped-pulse amplifiers with high average power are possible with novel high-power Yb:YAG amplifiers with kW-level output powers. We demonstrate a compact wavelength-tunable sub-30-fs amplifier with 11.4 W average power with 20.7% pump-to-signal conversion efficiency. For parametric amplification, a beta-barium borate crystal is pumped by a 140 W, 1 ps Yb:YAG InnoSlab amplifier at 3.25 MHz repetition rate. The broadband seed is generated via supercontinuum generation in a YAG crystal.

  6. Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

    DEFF Research Database (Denmark)

    Bertelsen, Anders; Lorenzen, Ebbe L; Brink, Carsten

    2011-01-01

    Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR......) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency...

  7. Dose rate distribution in the containment of the CAREM-25 reactor during full power operation

    Energy Technology Data Exchange (ETDEWEB)

    Jatuff, Fabian E. [Investigacion Aplicada SE (INVAP), San Carlos de Bariloche (Argentina)

    1997-12-01

    The estimation of dose rates in the containment of the CAREM-25 reactor during full power (100 MW) operation was performed in order to: (i) verify the ordinary concrete biological shieldings proposed, and (ii) classify the different rooms from the radiation protection viewpoint. Thirteen relevant radiation sources were characterized, and the dose rate distribution corresponding to each of the most relevant reported in the form of isodose maps. The results show the utmost importance of the N-16 source due to the exposed layout of the pressure vessel. (author). 7 refs., 10 figs., 1 tab.

  8. Inter-island optical link demonstration using high-data-rate pulse-position modulation

    Science.gov (United States)

    Bacher, Michael; Arnold, Felix; Thieme, Björn

    2014-03-01

    The growing data-rate demand on satellite communication systems has led to the increased interest in optical space communication solutions for uplinks and downlinks between satellites and ground stations. As one example for applications that benefit from higher data-rates offered by optical links, RUAG Space studied an uplink scenario from an Unmanned Aerial Vehicle (UAV) to a Geostationary Orbit (GEO), under the European Space Agency project formally known as "Optical Communications Transceiver for Atmospheric Links" (OCTAL). Particularly suitable for optical links through turbulent atmospheres are robust Pulse Position Modulation (PPM) schemes. Communication electronics using a Multi-Pulse PPM (MPPM) scheme have been developed, increasing the data-rate compared to traditional PPM at a constant peak-to-average ratio while allowing a widely configurable data-rate range. The communication system was tested together with a newly developed receiver and transmitter at a wavelength of 1055nm in a field test campaign on the Canary Islands, where the transmitter telescope was located on La Palma while the receiver was installed within the ESA Optical Ground Station on Tenerife. The nearly horizontal link between the two islands with a link distance of 142km allowed validation of relevant system performances under stringent atmospheric conditions. A data-rate of more than 360Mbps could be demonstrated using MPPM, while nearly 220Mbps could be achieved with traditional PPM, well exceeding the targeted data-rate of the studied UAV-to-GEO scenario. Following an introduction on the applied MPPM schemes, the architecture of the test setup is described, different modulation schemes are compared and the test results of this Inter-Island Test Campaign performed in October 2012 are presented.

  9. The Effect of Local Irradiation in Prevention and Reversal of Acute Rejection of Transplanted Kidney with High-dose Steroid Pulse

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I. H.; Ha, S. W.; Park, C. I.; Kim, S. T. [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    From 1979 to 1984, 39 local allograft irradiations were given to 29 patients: 10 irradiations were administered for prevention and 29 for reversal of acute rejection of transplanted kidney. Three doses of 150 cGy every other day were combined with high-dose of methylprednisolone pulse (1 gm/day) for 3 days. For prevention of acute rejection, local irradiation was delivered on the days 1, 3, and 5 after the transplantation, and for reversal, irradiation started after the diagnosis of acute rejection. Eight out of 10 patients irradiated for prevention had acute allograft rejection, and, what is more, there was no surviving graft at 15 months after transplantation. Reversal of acute rejection was achieved in 71%. When the pre-irradiation level of serum creatinine was below 5.5 mg%, the reversal rate was 93%, but above 5.5 mg% the reversal rate was only 17% (p<0.01). Reirradiation after failure was not successful. Among 15 reversed patients, 7 (47%) had subsequent rejection (s). The functional graft survivals at 6 month, 1, 2, and 3 year were 70%, 65%, 54%, and 65%, respectively. Therapeutic irradiation resulted in better graft survival when serum creatinine was below 5.5 mg% (p<0.001) or when irradiation started within 15 days after the diagnosis of acute rejection (p<0.001)

  10. Ruthenium-106 brachytherapy for thick uveal melanoma: reappraisal of apex and base dose radiation and dose rate

    Directory of Open Access Journals (Sweden)

    Masood Naseripour

    2016-02-01

    Full Text Available Purpose: To evaluate the outcomes of ruthenium-106 ( 106 Ru brachytherapy in terms of radiation parameters in patients with thick uveal melanomas. Material and methods: Medical records of 51 patients with thick (thickness ≥ 7 mm and < 11 mm uveal melanoma treated with 106 Ru brachytherapy during a ten-year period were reviewed. Radiation parameters, tumor regression, best corrected visual acuity (BCVA, and treatment-related complications were assessed. Results: Fifty one eyes of 51 consecutive patients including 25 men and 26 women with a mean age of 50.5 ± 15.2 years were enrolled. Patients were followed for 36.1 ± 26.5 months (mean ± SD. Mean radiation dose to tumor apex and to sclera were 71 (± 19.2 Gy and 1269 (± 168.2 Gy. Radiation dose rates to tumor apex and to sclera were 0.37 (± 0.14 Gy/h and 6.44 (± 1.50 Gy/h. Globe preservation was achieved in 82.4%. Preoperative mean tumor thickness of 8.1 (± 0.9 mm decreased to 4.5 (± 1.6 mm, 3.4 (± 1.4 mm, and 3.0 (± 1.46 mm at 12, 24, and 48 months after brachytherapy (p = 0.03. Four eyes that did not show regression after 6 months of brachytherapy were enucleated. Secondary enucleation was performed in 5 eyes because of tumor recurrence or neovascular glaucoma. Tumor recurrence was evident in 6 (11.8% patients. Mean Log MAR (magnification requirement visual acuity declined from 0.75 (± 0.63 to 0.94 (± 0.5 (p = 0.04. Best corrected visual acuity of 20/200 or worse was recorded in 37% of the patients at the time of diagnosis and 61.7% of the patients at last exam (p = 0.04. Non-proliferative and proliferative radiation-induced retinopathy was observed in 20 and 7 eyes. Conclusions : Thick uveal melanomas are amenable to 106 Ru brachytherapy with less than recommended apex radiation dose and dose rates.

  11. Statistical variability and confidence intervals for planar dose QA pass rates

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Daniel W.; Nelms, Benjamin E.; Attwood, Kristopher; Kumaraswamy, Lalith; Podgorsak, Matthew B. [Department of Physics, State University of New York at Buffalo, Buffalo, New York 14260 (United States) and Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Department of Biostatistics, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Molecular and Cellular Biophysics and Biochemistry, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States) and Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14214 (United States)

    2011-11-15

    Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization

  12. Broadly wavelength- and pulse width-tunable high-repetition rate light pulses from soliton self-frequency shifting photonic crystal fiber integrated with a frequency doubling crystal.

    Science.gov (United States)

    Lanin, Aleksandr A; Fedotov, Andrei B; Zheltikov, Aleksei M

    2012-09-01

    Soliton self-frequency shift (SSFS) in a photonic crystal fiber (PCF) pumped by a long-cavity mode-locked Cr:forsterite laser is integrated with second harmonic generation (SHG) in a nonlinear crystal to generate ultrashort light pulses tunable within the range of wavelengths from 680 to 1800 nm at a repetition rate of 20 MHz. The pulse width of the second harmonic output is tuned from 70 to 600 fs by varying the thickness of the nonlinear crystal, beam-focusing geometry, and the wavelength of the soliton PCF output. Wavelength-tunable pulses generated through a combination of SSFS and SHG are ideally suited for coherent Raman microspectroscopy at high repetition rates, as verified by experiments on synthetic diamond and polystyrene films.

  13. Assessment of potential radiation dose rates to marine organisms around the Korean Peninsula

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Myung [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Lee, Jun Ho [University of Science and Technology, Daejeon (Korea, Republic of)

    2016-05-15

    It is very difficult to set a regulatory guidance or criteria for the protection of non-human species from the ionizing radiation, because there are no generally or internationally accepted methods for demonstrating the compliance with such criteria. It is needed that Korea develop the primary dose rate standards for the protection of both aquatic and terrestrial biota in the near future. The potential dose rates due to both external and internal radiation exposures to marine organisms such as plaice/flounder, gray mullet, and brown seaweed collected within territorial seas around the Korean Peninsula were estimated. The total dose rates to plaice/flounder, gray mullet and brown seaweed due to {sup 40}K, a primordial radionuclide in marine environment, were found to be 0.2%, 0.08% and 0.3% of approximately the values of the Derived Consideration Reference Levels (DCRLs, i.e. 1-10 mGy d{sup -1}), respectively, as suggested by the International Commission on Radiological Protection (ICRP) publication 124. The total dose rates to marine fishes and brown seaweed due to anthropogenic radionuclides such as {sup 90}Sr, {sup 137}Cs and {sup 239+240}Pu were considered to be negligible compared to the total dose rate due to {sup 40}K. The external exposure to benthic fish due to all radionuclides was much higher than that of pelagic fish. From this study, it is recommended that the further study is required to develop a national regulatory guidance for the evaluation of doses to non-human species.

  14. Dose-rate dependence of epitaxial diodes response for gamma dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, J.A.C.; Santos, T.C. dos; Barbosa, R.F.; Pascoalino, K.C.S.; Bueno, C.C. [Instituto de Pesquisas Energeticas e Nucleares (CTR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2011-07-01

    Full text: In this work, we present the preliminary results about the evaluation of dose-rate influence on the response of rad-hard epitaxial (EPI) diodes for on-line gamma-ray dosimetry using Co-60 irradiators. The diodes used were processed at University of Hamburg on n-type 75 micrometer thick epitaxial silicon layer (nominal resistivity of 69 Ohm.cm) grown on a highly doped n-type 300 micrometer thick Czochralski (Cz) silicon substrate. Two samples of EPI diodes were investigated: EPI-08 and EPI-10 - both non-irradiated previously. These devices, with 5mm x 5mm active area, were housed in a PMMA probe and connected, in a photovoltaic mode, to a Keithley 617 electrometer. The EPI-10 device irradiation was performed in the Radiation Technology Center at IPEN-CNEN/SP using a Co-60 irradiator (Gammacell 220 - Nordion) which delivers a dose rate of 2.16 kGy/h, while the EPI-08 device irradiation was performed in Nuclear Energy Department at UFPE/PE using the same model Co-60 irradiator, but with a dose-rate of 7.47 kGy/h. During the irradiation, the devices photocurrents were monitored as a function of the exposure time. The diodes were irradiated at room temperature. The dose-response curves of the EPI diodes were achieved through the integration of the current signals as a function of the exposure time. The normalized current signals as a function of the dose evidenced a decrease of about 60 percent from the initial current for the first 100 kGy dose received. After 500 kGy of exposure, the current signals stabilize (ou maintain stable). The dose-response curves behave as a second order polynomial fit, with correlation coefficients of about 0.99991 and 0.99995, respectively to EPI-10 and EPI-08 diodes. The preliminary results obtained evinced that the EPI diodes response are not dose-rate dependent within the range of 2.16 kGy/h up to 7.47 kGy/h. On the other hand, the devices studied are tolerant to radiation damages for total absorbed doses of approximately 550

  15. Environmental radioactivity in the UK: the airborne geophysical view of dose rate estimates.

    Science.gov (United States)

    Beamish, David

    2014-12-01

    This study considers UK airborne gamma-ray data obtained through a series of high spatial resolution, low altitude surveys over the past decade. The ground concentrations of the naturally occurring radionuclides Potassium, Thorium and Uranium are converted to air absorbed dose rates and these are used to assess terrestrial exposure levels from both natural and technologically enhanced sources. The high resolution airborne information is also assessed alongside existing knowledge from soil sampling and ground-based measurements of exposure levels. The surveys have sampled an extensive number of the UK lithological bedrock formations and the statistical information provides examples of low dose rate lithologies (the formations that characterise much of southern England) to the highest sustained values associated with granitic terrains. The maximum dose rates (e.g. >300 nGy h(-1)) encountered across the sampled granitic terrains are found to vary by a factor of 2. Excluding granitic terrains, the most spatially extensive dose rates (>50 nGy h(-1)) are found in association with the Mercia Mudstone Group (Triassic argillaceous mudstones) of eastern England. Geological associations between high dose rate and high radon values are also noted. Recent studies of the datasets have revealed the extent of source rock (i.e. bedrock) flux attenuation by soil moisture in conjunction with the density and porosity of the temperate latitude soils found in the UK. The presence or absence of soil cover (and associated presence or absence of attenuation) appears to account for a range of localised variations in the exposure levels encountered. The hypothesis is supported by a study of an extensive combined data set of dose rates obtained from soil sampling and by airborne geophysical survey. With no attenuation factors applied, except those intrinsic to the airborne estimates, a bias to high values of between 10 and 15 nGy h(-1) is observed in the soil data. A wide range of

  16. Indoor terrestrial gamma dose rate mapping in France: a case study using two different geostatistical models.

    Science.gov (United States)

    Warnery, E; Ielsch, G; Lajaunie, C; Cale, E; Wackernagel, H; Debayle, C; Guillevic, J

    2015-01-01

    Terrestrial gamma dose rates show important spatial variations in France. Previous studies resulted in maps of arithmetic means of indoor terrestrial gamma dose rates by "departement" (French district). However, numerous areas could not be characterized due to the lack of data. The aim of our work was to obtain more precise estimates of the spatial variability of indoor terrestrial gamma dose rates in France by using a more recent and complete data base and geostatistics. The study was based on the exploitation of 97,595 measurements results distributed in 17,404 locations covering all of France. Measurements were done by the Institute for Radioprotection and Nuclear Safety (IRSN) using RPL (Radio Photo Luminescent) dosimeters, exposed during several months between years 2011 and 2012 in French dentist surgeries and veterinary clinics. The data used came from dosimeters which were not exposed to anthropic sources. After removing the cosmic rays contribution in order to study only the telluric gamma radiation, it was decided to work with the arithmetic means of the time-series measurements, weighted by the time-exposure of the dosimeters, for each location. The values varied between 13 and 349 nSv/h, with an arithmetic mean of 76 nSv/h. The observed statistical distribution of the gamma dose rates was skewed to the right. Firstly, ordinary kriging was performed in order to predict the gamma dose rate on cells of 1*1 km(2), all over the domain. The second step of the study was to use an auxiliary variable in estimates. The IRSN achieved in 2010 a classification of the French geological formations, characterizing their uranium potential on the bases of geology and local measurement results of rocks uranium content. This information is georeferenced in a map at the scale 1:1,000,000. The geological uranium potential (GUP) was classified in 5 qualitative categories. As telluric gamma rays mostly come from the progenies of the (238)Uranium series present in rocks, this

  17. Feasibility study of volumetric modulated arc therapy with constant dose rate for endometrial cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ruijie [Department of Radiation Oncology, Peking University Third Hospital, Beijing (China); Wang, Junjie, E-mail: junjiewang47@yahoo.com [Department of Radiation Oncology, Peking University Third Hospital, Beijing (China); Xu, Feng [Department of Biomedical Engineering, Peking University Third Hospital, Beijing (China); Li, Hua [Department of Obstetrics and Gynecology, Peking University Third Hospital, Beijing (China); Zhang, Xile [Department of Radiation Oncology, Peking University Third Hospital, Beijing (China)

    2013-10-01

    To investigate the feasibility, efficiency, and delivery accuracy of volumetric modulated arc therapy with constant dose rate (VMAT-CDR) for whole-pelvic radiotherapy (WPRT) of endometrial cancer. The nine-field intensity-modulated radiotherapy (IMRT), VMAT with variable dose-rate (VMAT-VDR), and VMAT-CDR plans were created for 9 patients with endometrial cancer undergoing WPRT. The dose distribution of planning target volume (PTV), organs at risk (OARs), and normal tissue (NT) were compared. The monitor units (MUs) and treatment delivery time were also evaluated. For each VMAT-CDR plan, a dry run was performed to assess the dosimetric accuracy with MatriXX from IBA. Compared with IMRT, the VMAT-CDR plans delivered a slightly greater V{sub 20} of the bowel, bladder, pelvis bone, and NT, but significantly decreased the dose to the high-dose region of the rectum and pelvis bone. The MUs decreased from 1105 with IMRT to 628 with VMAT-CDR. The delivery time also decreased from 9.5 to 3.2 minutes. The average gamma pass rate was 95.6% at the 3%/3 mm criteria with MatriXX pretreatment verification for 9 patients. VMAT-CDR can achieve comparable plan quality with significant shorter delivery time and smaller number of MUs compared with IMRT for patients with endometrial cancer undergoing WPRT. It can be accurately delivered and be an alternative to IMRT on the linear accelerator without VDR capability.

  18. Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations

    Directory of Open Access Journals (Sweden)

    Artner J

    2012-08-01

    Full Text Available Juraj Artner, Balkan Cakir, Heiko Reichel, Friederike LattigDepartment of Orthopaedic Surgery, University of Ulm, RKU, GermanyBackground: The sacroiliac (SI joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique.Objective: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections.Study design: Comparative study with technical considerations.Methods: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided.Results: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy-guidance levels.Conclusion: Radiation dose of CT-guided SI joint injections can be

  19. A novel non-linear recursive filter design for extracting high rate pulse features in nuclear medicine imaging and spectroscopy.

    Science.gov (United States)

    Sajedi, Salar; Kamal Asl, Alireza; Ay, Mohammad R; Farahani, Mohammad H; Rahmim, Arman

    2013-06-01

    Applications in imaging and spectroscopy rely on pulse processing methods for appropriate data generation. Often, the particular method utilized does not highly impact data quality, whereas in some scenarios, such as in the presence of high count rates or high frequency pulses, this issue merits extra consideration. In the present study, a new approach for pulse processing in nuclear medicine imaging and spectroscopy is introduced and evaluated. The new non-linear recursive filter (NLRF) performs nonlinear processing of the input signal and extracts the main pulse characteristics, having the powerful ability to recover pulses that would ordinarily result in pulse pile-up. The filter design defines sampling frequencies lower than the Nyquist frequency. In the literature, for systems involving NaI(Tl) detectors and photomultiplier tubes (PMTs), with a signal bandwidth considered as 15 MHz, the sampling frequency should be at least 30 MHz (the Nyquist rate), whereas in the present work, a sampling rate of 3.3 MHz was shown to yield very promising results. This was obtained by exploiting the known shape feature instead of utilizing a general sampling algorithm. The simulation and experimental results show that the proposed filter enhances count rates in spectroscopy. With this filter, the system behaves almost identically as a general pulse detection system with a dead time considerably reduced to the new sampling time (300 ns). Furthermore, because of its unique feature for determining exact event times, the method could prove very useful in time-of-flight PET imaging.

  20. Mode-locked Yb-doped fiber laser emitting broadband pulses at ultra-low repetition rates

    CERN Document Server

    Bowen, Patrick; Provo, Richard; Harvey, John D; Broderick, Neil G R

    2016-01-01

    We report on an environmentally stable, Yb-doped, all-normal dispersion, mode-locked fibre laser that is capable of creating broadband pulses with ultra-low repetition rates. Specifically, through careful positioning of fibre sections in an all-PM-fibre cavity mode-locked with a nonlinear amplifying loop mirror, we achieve stable pulse trains with repetition rates as low as 506 kHz. The pulses have several nanojules of energy and are compressible down to ultrashort (< 500 fs) durations.

  1. Beam rate influence on dose distribution and fluence map in IMRT dynamic technique.

    Science.gov (United States)

    Slosarek, Krzysztof; Grządziel, Aleksandra; Osewski, Wojciech; Dolla, Lukasz; Bekman, Barbara; Petrovic, Borislava

    2012-01-01

    To examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values. Accelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered in high conformal dynamic techniques. Dose calculation was done for two different beam rates (100 MU/min and 600 MU/min) in an IMRT plan. For both, a comparison of Radiation Planning Index (RPI) and MU was conducted. Secondly, the comparison of optimal fluence maps and corresponding actual fluence maps was done. Next, actual fluence maps were measured and compared with the calculated ones. Gamma index was used for that assessment. Additionally, positions of each leaf of the MLC were controlled by home made software. Dose distribution obtained for lower beam rates was slightly better than for higher beam rates in terms of target coverage and risk structure protection. Lower numbers of MUs were achieved in 100 MU/min plans than in 600 MU/min plans. Actual fluence maps converted from optimal ones demonstrated more similarity in 100 MU/min plans. Better conformity of the measured maps to the calculated ones was obtained when a lower beam rate was applied. However, these differences were small. No correlation was found between quality of fluence map conversion and leaf motion accuracy. Execution of dynamic techniques is dependent on beam rate. However, these differences are minor. Analysis shows a slight superiority of a lower beam rate. It does not significantly affect treatment accuracy.

  2. The slope of the oxygen pulse curve does not depend on the maximal heart rate in elite soccer players

    Directory of Open Access Journals (Sweden)

    Raphael Rodrigues Perim

    2011-01-01

    Full Text Available INTRODUCTION: It is unknown whether an extremely high heart rate can affect oxygen pulse profile during progressive maximal exercise in healthy subjects. OBJECTIVE: Our aim was to compare relative oxygen pulse (adjusted for body weight curves in athletes at their maximal heart rate during treadmill cardiopulmonary exercise testing. METHODS: A total of 180 elite soccer players were categorized in quartiles according to their maximum heart rate values (n = 45. Oxygen consumption, maximum heart rate and relative oxygen pulse curves in the extreme quartiles, Q1 and Q4, were compared at intervals corresponding to 10% of the total duration of a cardiopulmonary exercise testing. RESULTS: Oxygen consumption was similar among all subjects during cardiopulmonary exercise testing; however subjects in Q1 started to exhibit lower maximum heart rate values when 20% of the test was complete. Conversely, the relative oxygen pulse was higher in this group when cardiopulmonary exercise testing was 40% complete (p<.01. Although the slopes of the lines were similar (p = .25, the regression intercepts differed (p<.01 between Q1 and Q4. During the last two minutes of testing, a flat or decreasing oxygen pulse was identified in 20% of the soccer players, and this trend was similar between subjects in Q1 and Q4. CONCLUSION: Relative oxygen pulse curve slopes, which serve as an indirect and non-invasive surrogate for stroke volume, suggest that the stroke volume is similar in young and aerobically fit subjects regardless of the maximum heart rate reached.

  3. Comparative influence of dose rate and radiation nature, on lethality after big mammals irradiation; Influence, a dose egale, du debit de dose et de la nature du rayonnement sur la mortalite

    Energy Technology Data Exchange (ETDEWEB)

    Destombe, C.; Le Fleche, Ph.; Grasseau, A.; Reynal, A. [Etablissement Technique Central de l`Armement (ETCA), 94 - Arcueil (France)

    1997-12-31

    For the same dose and the 30 days lethality as biological criterion, the dose rate influence is more important than the radiation nature on the results of an big mammals total body irradiation. (authors)

  4. Remote Sensing of Radiation Dose Rate by Customizing an Autonomous Robot

    Science.gov (United States)

    Kobayashi, T.; Nakahara, M.; Morisato, K.; Takashina, T.; Kanematsu, H.

    2012-03-01

    Distribution of radiation dose was measured by customizing an autonomous cleaning robot "Roomba" and a scintillation counter. The robot was used as a vehicle carrying the scintillation survey meter, and was additionally equipped with an H8 micro computer to remote-control the vehicle and to send measured data. The data obtained were arranged with position data, and then the distribution map of the radiation dose rate was produced. Manual, programmed and autonomous driving tests were conducted, and all performances were verified. That is, for each operational mode, the measurements both with moving and with discrete moving were tried in and outside of a room. Consequently, it has been confirmed that remote sensing of radiation dose rate is possible by customizing a robot on market.

  5. A dose rate model predicting radon-induced lung cancer risk in rats

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, W.; Lettner, H. (Salzburg Univ. (Austria). Div. of Biophysics); Crawford-Brown, D.J. (North Carolina Univ., Chapel Hill, NC (United States). Dept. of Environmental Sciences and Engineering)

    1992-01-01

    The laboratory rat has been used in inhalation studies as a surrogate to estimate human lung cancer risk following exposure to ambient radon progeny. Deposition, mucociliary clearance and dosimetry for the inhalation of radon progeny in the rat lung have been simulated for a variety of inhalation conditions. A state-vector model for radiation carcinogenesis has then been applied to predict the carcinogenic risk in the rat lung for different doses and dose rates. The model is based on the concepts of initiation and promotion, with the irradiation acting both to damage intercellular structures and to change the state of cells surrounding an initiated cell. Predicted lung cancer incidences show fair agreement with the experimental data. Consistent with the experimental evidence is the inverse dose rate effect observed for intermediate cumulative exposures. (author).

  6. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shwetha, Bondel [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Ravikumar, Manickam, E-mail: drravikumarm@gmail.com [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Supe, Sanjay S.; Sathiyan, Saminathan [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Lokesh, Vishwanath [Department of Radiotherapy, Kidwai, Memorial Institute of Oncology, Bangalore (India); Keshava, Subbarao L. [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India)

    2012-04-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  7. Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning.

    Science.gov (United States)

    Bahadur, Yasir A; Constantinescu, Camelia; Hassouna, Ashraf H; Eltaher, Maha M; Ghassal, Noor M; Awad, Nesreen A

    2015-01-01

    To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff HDR brachytherapy using a multichannel applicator. For each brachytherapy fraction, two inverse treatment plans (for central channel and multichannel loadings) were performed and compared. The advantage of fractional re-planning was also investigated. Dose-volume-histogram (DVH) analysis showed limited, but statistically significant difference (p = 0.007) regarding clinical-target-volume dose coverage between single and multichannel approaches. For the organs-at-risk rectum and bladder, the use of multichannel applicator demonstrated a noticeable dose reduction, when compared to single channel, but statistically significant for rectum only (p = 0.0001). For D2cc of rectum, an average fractional dose of 6.1 ± 0.7 Gy resulted for single channel vs. 5.1 ± 0.6 Gy for multichannel. For D2cc of bladder, an average fractional dose of 5 ± 0.9 Gy occurred for single channel vs. 4.9 ± 0.8 Gy for multichannel. The dosimetric benefit of fractional re-planning was demonstrated: DVH analysis showed large, but not statistically significant differences between first fraction plan and fractional re-planning, due to large inter-fraction variations for rectum and bladder positioning and filling. Vaginal HDR brachytherapy using a multichannel vaginal applicator and inverse planning provides dosimetric advantages over single channel cylinder, by reducing the dose to organs at risk without compromising the target volume coverage, but at the expense of an increased vaginal mucosa dose. Due to large inter-fraction dose variations, we recommend individual fraction treatment plan optimization.

  8. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications.

    Science.gov (United States)

    Shwetha, Bondel; Ravikumar, Manickam; Supe, Sanjay S; Sathiyan, Saminathan; Lokesh, Vishwanath; Keshava, Subbarao L

    2012-01-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  9. 500 MW peak power degenerated optical parametric amplifier delivering 52 fs pulses at 97 kHz repetition rate.

    Science.gov (United States)

    Rothhardt, J; Hädrich, S; Röser, F; Limpert, J; Tünnermann, A

    2008-06-09

    We present a high peak power degenerated parametric amplifier operating at 1030 nm and 97 kHz repetition rate. Pulses of a state-of-the art fiber chirped-pulse amplification (FCPA) system with 840 fs pulse duration and 410 microJ pulse energy are used as pump and seed source for a two stage optical parametric amplifier. Additional spectral broadening of the seed signal in a photonic crystal fiber creates enough bandwidth for ultrashort pulse generation. Subsequent amplification of the broadband seed signal in two 1 mm BBO crystals results in 41 microJ output pulse energy. Compression in a SF 11 prism compressor yields 37 microJ pulses as short as 52 fs. Thus, pulse shortening of more than one order of magnitude is achieved. Further scaling in terms of average power and pulse energy seems possible and will be discussed, since both concepts involved, the fiber laser and the parametric amplifier have the reputation to be immune against thermo-optical effects.

  10. Evaluation of excess life time cancer risk from gamma dose rates in Jhelum valley

    Directory of Open Access Journals (Sweden)

    Muhammad Rafique

    2014-01-01

    Full Text Available Human beings are continuously exposed to the radiations coming from outside and inside their bodies. Outside and inside radiations are coming from ground, building materials, food, air, the universe and even elements within human own bodies. According to UNSCEAR 2000 report, background radiations deliver an average effective dose of 2.4 mSv per person worldwide. Sustained exposure from high background radiation levels may pose substantial health threats to general public. In the current study we are presenting the results of ambient outdoor gamma dose rates measured for Jhelum valley of the state of Azad Kashmir. This study has been carried out by using Ludlum micrometer-19 which is an active and portable detector. Effects of different parameters of interest on the measured values of gamma dose rates have been investigated. For the region under investigation, minimum and maximum indoor gamma dose rates were found as 610 ± 4.05 μGy·y−1 and 1372 ± 2.7 μGy·y−1, respectively, whilst minimum and maximum outdoor gamma dose rates were found as 495 ± 4.49 μGy·y−1 and 1296 ± 2.78 μGy·y−1, respectively. Overall arithmetic mean (A.M and geometric mean (G.M values of gamma dose rates for indoor and outdoor measurements were found as 940 ± 3.26 μGy·y−1, 892 ± 3.35 μGy·y−1 and 928 ± 3.28 μGy·y−1, 880 ± 3.37 μGy·y−1 respectively. Excess life time cancer risk (ELCR for indoor exposure ranges from 1.057 × 10−3 to 2.377 × 10−3 with an average value of 1.629 × 10−3. For outdoor exposure, ELCR varies from 0.352 × 10−3 to 0.792 × 10−3 with mean value of 0.543 × 10−3. Average values of indoor gamma doses were found to be greater than the world population-weighted average for indoor gamma dose rates (780 μGy·y−1 or 89 nGy h−1.

  11. Fast Back Propagation Learning Using Optimization of Learning Rate for Pulsed Neural Networks

    Science.gov (United States)

    Yamamoto, Kenji; Koakutsu, Seiichi; Okamoto, Takashi; Hirata, Hironori

    Neural Networks (NN) are widely applied to information processing because of its nonlinear processing capability. Digital hardware implementation of NN seems to be effective in construction of NN systems in which real-time operation and much further wide applications are possible. However, the digital hardware implementation of analogue NN is very difficult because we have to fulfill the restrictions about circuit resource, such as circuit scale, arrangement, and wiring. A technique that uses pulsed neuron model instead of analogue neuron model as a method of solving this problem has been proposed, and its effectiveness has been confirmed. To construct Pulsed Neural Networks (PNN), Back Propagation (BP) learning has been proposed. However, BP learning takes much time to construct PNN compared with the learning of analogue NN. Therefore some method to speed up BP learning of PNN is necessary. In this paper, we propose a fast BP learning using optimization of learning rate for PNN. In the proposed method, the learning rate is optimized so as to speed up the learning at every learning epoch. To evaluate the proposed method, we apply it to some pattern recognition problems, such as XOR, 3-bits parity, and digit recognition. Results of computational experiments indicate the validity of the proposed method.

  12. High rate deposition of thin film cadmium sulphide by pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lisco, F., E-mail: F.Lisco@lboro.ac.uk [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Kaminski, P.M.; Abbas, A.; Bowers, J.W.; Claudio, G. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Losurdo, M. [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR, via Orabona 4, 70126 Bari (Italy); Walls, J.M. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom)

    2015-01-01

    Cadmium Sulphide (CdS) is an important n-type semiconductor widely used as a window layer in thin film photovoltaics Copper Indium Selenide, Copper Indium Gallium (di)Selenide, Copper Zinc Tin Sulphide and Cadmium Telluride (CdTe). Cadmium Sulphide has been deposited using a number of techniques but these techniques can be slow (chemical bath deposition and Radio Frequency sputtering) or the uniformity and the control of thickness can be relatively difficult (close space sublimation). In this paper we report on the development of a process using pulsed Direct Current magnetron sputtering which allows nanometre control of thin film thickness using time only. The CdS thin films deposited in this process are highly uniform and smooth. They exhibit the preferred hexagonal structure at room temperature deposition and they have excellent optical properties. Importantly, the process is highly stable despite the use of a semi-insulating magnetron target. Moreover, the process is very fast. The deposition rate using 1.5 kW of power to a 6-inch circular magnetron was measured to be greater than 8 nm/s. This makes the process suitable for industrial deployment. - Highlights: • Pulsed DC magnetron sputtering of CdS • High deposition rate deposition • Uniform, pinhole free films.

  13. Characterization of MHz pulse repetition rate femtosecond laser-irradiated gold-coated silicon surfaces

    Directory of Open Access Journals (Sweden)

    Venkatakrishnan Krishnan

    2011-01-01

    Full Text Available Abstract In this study, MHz pulse repetition rate femtosecond laser-irradiated gold-coated silicon surfaces under ambient condition were characterized by scanning electron microscopy (SEM, transmission electron microscopy (TEM, X-ray diffraction analysis (XRD, and X-ray photoelectron spectroscopy (XPS. The radiation fluence used was 0.5 J/cm2 at a pulse repetition rate of 25 MHz with 1 ms interaction time. SEM analysis of the irradiated surfaces showed self-assembled intermingled weblike nanofibrous structure in and around the laser-irradiated spots. Further TEM investigation on this nanostructure revealed that the nanofibrous structure is formed due to aggregation of Au-Si/Si nanoparticles. The XRD peaks at 32.2°, 39.7°, and 62.5° were identified as (200, (211, and (321 reflections, respectively, corresponding to gold silicide. In addition, the observed chemical shift of Au 4f and Si 2p lines in XPS spectrum of the irradiated surface illustrated the presence of gold silicide at the irradiated surface. The generation of Si/Au-Si alloy fibrous nanoparticles aggregate is explained by the nucleation and subsequent condensation of vapor in the plasma plume during irradiation and expulsion of molten material due to high plasma pressure.

  14. Dependence of dose coefficients for {sup 239}Pu on transfer rates and absorption parameters

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K.; Sekimoto, H. [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Tokyo (Japan); Ishigure, N. [Division of Radiotoxicology and Protection, National Institute of Radiological Sciences, Chiba (Japan)

    2000-05-01

    As it is reported of the biokinetic models and parameter values of the International Commission on Radiological Protection (ICRP) for dose estimation have uncertainties owing to insufficiency of human data. For most radionuclides, the data underlying such models and parameters of ICRP usually depend on animal experiments. Moreover, these values or model parameter are also greatly different between mammalian species. Recently, various radiation protection organizations are considering the biokinetic uncertainties from standpoints of data's sources, quality and completeness. In practice, a sensitivity analysis of doses to parameters is significant for the purpose of risk assessment. In general, movement or material in the body is depicted as a system of first-order processes, and parameter values are expressed as transfer rates between compartments. In this study, we made a code to reproduce the ICRP's dose coefficients for {sup 239}Pu, which is one of the most important elements for occupational exposure and its effective dose is much concerned with its own distribution in the body for dominance of alpha-decay. By using this code, we modified each transfer rate in a factor of 2, 3 and 4 in order to evaluate the effects, and calculated the sensitivities of effective doses due to these changes. Additionally, we examined the effects of modification of absorption parameters f{sub r}, S{sub r} and S{sub s}, which represent the absorption of particles from respiratory tract into blood. Consequently, the transfer rates that give a large sensitivity were specified, and it was shown that changes of transfer rates and absorption parameters are not so influential on effective doses for {sup 239}Pu in many cases. (author)

  15. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  16. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Juergen;

    2016-01-01

    PURPOSE: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. METHODS AND MATERIALS: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immed...

  17. Effects of gamma irradiation dose rate on microbiological and physical quality of mushrooms (Agaricus bisporus)

    Energy Technology Data Exchange (ETDEWEB)

    Beaulieu, M.; Lacroix, M.; Charbonneau, R.; Laberge, I.; Gagnon, M. (Canadian Irradiation Centre, Laval, PQ (Canada))

    1992-01-01

    The effects of gamma irradiation (2 kGy) and dose rate of irradiation (4.5 and 32.0 kGy/h) on increasing the shelf-life and some quality properties of the mushrooms (Agaricus bisporus) were investigated during storage at 15 deg C and 90% R.H. The retardation of mushroom growth and ageing by reduction of gamma irradiation dose rate (4.5 kGy) was observed by measurements of the cap opening, the stipe increase, the cap diameter, the weight loss and the color of the caps. The color was measured in order to evaluate the lightness with the L value measurement and the color changes were measured in terms of lightness, hue and chroma. The control of fungal and bacterial diseases were also evaluated. The irradiation of mushrooms at both dose rates of irradiation was found to be effective in lowering microorganism counts initially and throughout storage and increased the shelf-life by four days. This study also showed that mushrooms exposed to a lower dose rate (4.5 kGy/h) of irradiation preserve the whiteness and reduce the stripe increase of mushrooms during storage.

  18. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    NARCIS (Netherlands)

    Borot, Maxence; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-01-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance.

  19. Monitoring performance of the cameras under the high dose-rate gamma ray environments.

    Science.gov (United States)

    Cho, Jai Wan; Choi, Young Soo; Jeong, Kyung Min

    2014-05-01

    CCD/CMOS cameras, loaded on a robot system, are generally used as the eye of the robot and monitoring unit. A major problem that arises when dealing with images provided by CCD/CMOS cameras under severe accident situations of a nuclear power plant is the presence of speckles owing to the high dose-rate gamma irradiation fields. To use a CCD/CMOS camera as a monitoring unit in a high radiation area, the legibility of the camera image in such intense gamma-radiation fields should therefore be defined. In this paper, the authors describe the monitoring index as a figure of merit of the camera's legibleness under a high dose-rate gamma ray irradiation environment. From a low dose-rate (10 Gy h) to a high dose-rate (200 Gy h) level, the legible performances of the cameras owing to the speckles are evaluated. The numbers of speckles generated by gamma ray irradiation in the camera image are calculated by an image processing technique. The legibility of the sensor indicator (thermo/hygrometer) owing to the number of speckles is also presented.

  20. Using rainfall radar data to improve interpolated maps of dose rate in the Netherlands

    NARCIS (Netherlands)

    Hiemstra, P.H.; Pebesma, E.J.; Heuvelink, G.B.M.; Twenhöfel, C.J.W.

    2010-01-01

    The radiation monitoring network in the Netherlands is designed to detect and track increased radiation levels, dose rate more specifically, in 10-minute intervals. The network consists of 153 monitoring stations. Washout of radon progeny by rainfall is the most important cause of natural variations

  1. Measurement bias dependence of enhanced bipolar gain degradation at low dose rates

    Energy Technology Data Exchange (ETDEWEB)

    Witczak, S.C.; Lacoe, R.C.; Mayer, D.C. [Aerospace Corp., Los Angeles, CA (United States). Electronics Technology Center; Schrimpf, R.D.; Barnaby, H.J.; Galloway, K.F. [Vanderbilt Univ., Nashville, TN (United States). Dept. of Electrical and Computer Engineering; Pease, R.L. [RLP Research, Inc., Albuquerque, NM (United States); Fleetwood, D.M. [Sandia National Labs., Albuquerque, NM (United States)

    1998-03-01

    Oxide trapped charge, field effects from emitter metallization, and high level injection phenomena moderate enhanced gain degradation of lateral pnp transistors at low dose rates. Hardness assurance tests at elevated irradiation temperatures require larger design margins for low power measurement biases.

  2. A computational study to evaluate indoor gamma dose-rate on the basis of outdoor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nuccetelli, C.; Menghi, E.; Bochicchio, F. [Istituto Superiore di Sanita, Roma (Italy)

    2006-07-01

    A new method to estimate the indoor gamma dose rate has been developed. This method is based on outdoor gamma dose rate measurements and a computational model that requires the knowledge of some structural and geometrical characteristics of the dwelling. It can be a very useful tool in situations in which it is impossible entering the dwellings to measure the indoor gamma dose rate, such as epidemiological studies and other surveys. To validate the method, estimates and actual indoor measurements have been compared for a sample of dwellings. In a first phase, indoor gamma dose rate estimates were obtained using the detailed dwelling information contained in questionnaire filled-in during the indoor measurements. This first comparison gave excellent results. A more general and less site dependent approach has now been implemented, assuming average values for many indoor parameters instead of using questionnaire data, in order to evaluate the predictive characteristics of this method for a practical use. In this paper, the new procedure is presented and the results obtained till now are summarized. (authors)

  3. Time-driven activity-based costing of low-dose-rate and high-dose-rate brachytherapy for low-risk prostate cancer.

    Science.gov (United States)

    Ilg, Annette M; Laviana, Aaron A; Kamrava, Mitchell; Veruttipong, Darlene; Steinberg, Michael; Park, Sang-June; Burke, Michael A; Niedzwiecki, Douglas; Kupelian, Patrick A; Saigal, Christopher

    Cost estimates through traditional hospital accounting systems are often arbitrary and ambiguous. We used time-driven activity-based costing (TDABC) to determine the true cost of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy for prostate cancer and demonstrate opportunities for cost containment at an academic referral center. We implemented TDABC for patients treated with I-125, preplanned LDR and computed tomography based HDR brachytherapy with two implants from initial consultation through 12-month followup. We constructed detailed process maps for provision of both HDR and LDR. Personnel, space, equipment, and material costs of each step were identified and used to derive capacity cost rates, defined as price per minute. Each capacity cost rate was then multiplied by the relevant process time and products were summed to determine total cost of care. The calculated cost to deliver HDR was greater than LDR by $2,668.86 ($9,538 vs. $6,869). The first and second HDR treatment day cost $3,999.67 and $3,955.67, whereas LDR was delivered on one treatment day and cost $3,887.55. The greatest overall cost driver for both LDR and HDR was personnel at 65.6% ($4,506.82) and 67.0% ($6,387.27) of the total cost. After personnel costs, disposable materials contributed the second most for LDR ($1,920.66, 28.0%) and for HDR ($2,295.94, 24.0%). With TDABC, the true costs to deliver LDR and HDR from the health system perspective were derived. Analysis by physicians and hospital administrators regarding the cost of care afforded redesign opportunities including delivering HDR as one implant. Our work underscores the need to assess clinical outcomes to understand the true difference in value between these modalities. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. High-pressure pulsed avalanche discharges: Formulas for required preionization density and rate for homogeneity

    Energy Technology Data Exchange (ETDEWEB)

    Brenning, N.; Axnaes, I.; Nilsson, J.O.; Eninger, J.E. [Royal Inst. of Tech., Stockholm (Sweden)

    1997-02-01

    The requirements on preionization for the formation of spatially homogeneous pulsed avalanche discharges are examined. The authors derive two formulas which apply in the case of a slowly rising electric field, one which gives the required preionization density at breakdown, and one which gives the required preionization rate. These quantities are expressed as functions of the electrochemical properties of the gas, the neutral density, and the electric field rise time. They also treat the statistical effect that the electrons tend to form groups, in contrast to being randomly distributed in space, during the prebreakdown phase. This process is found to increase the required preionization rate significantly, typically by a factor of five for a discharge at atmospheric pressure. Homogeneous high-pressure discharges have been used for laser excitation, and have also been proposed for chemical plasma processing (ozone production) because of their good scaling properties and high efficiency.

  5. Shielding optimisation of the ITER ICH&CD antenna for shutdown dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Andrew, E-mail: andrew.turner@ccfe.ac.uk [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Leichtle, Dieter [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Lamalle, Philippe; Levesy, Bruno [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St., Paul-lez-Durance (France); Meunier, Lionel [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Polunovskiy, Eduard [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St., Paul-lez-Durance (France); Sartori, Roberta [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Shannon, Mark [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2015-10-15

    Highlights: • Neutronics analysis on the ITER ICH&CD system conducted to reduce shutdown dose rate. • Several designs for shielding the port plug gaps were modelled. • Shielding significantly reduced interspace dose rate but still exceed project requirements. • Design optimisation of the ICH port is continuing. • Significant contributions from other ports require an integrated modelling approach. - Abstract: The Ion Cyclotron Heating and Current Drive (ICH&CD) system will reside in ITER equatorial port plugs 13 and 15. Shutdown dose rates (SDDR) within the port interspace are required to be less than 100 μSv/h at 10{sup 6} s cooling. A significant contribution to the SDDR results from neutrons streaming down gaps around the port frame, and the mitigation of this streaming is the main subject of these analyses. An updated MCNP model of the antenna was created and integrated into an ITER reference model. Shielding plates were defined in the port gaps, and scoping studies conducted to assess their effectiveness in several configurations, based on which a front dog-leg arrangement was selected for high resolution 3-D activation analysis using MCR2S. It was concluded that the selected configuration reduced the SDDR from ∼500 μSv/h to 220 μSv/h but were still in excess of dose rate requirements. Approximately 30% of this was due to cross-talk from neighbouring ports. In addition, increased dose rates were observed in the port interspace along the lines of sight of the removable vacuum transmission lines. Design optimisation is continuing, however an integrated approach is needed with regard to ITER port plug design and the shielding of surrounding systems.

  6. Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Feras Sendy

    2015-01-01

    Full Text Available Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67% received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225 of the patients. 28% (63/225 were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63 of failure received a second dose of methotrexate, and 37% (23/63 underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  7. Failure rate of single dose methotrexate in managment of ectopic pregnancy.

    Science.gov (United States)

    Sendy, Feras; AlShehri, Eman; AlAjmi, Amani; Bamanie, Elham; Appani, Surekha; Shams, Taghreed

    2015-01-01

    Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67%)) received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225) of the patients. 28% (63/225) were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63) of failure received a second dose of methotrexate, and 37% (23/63) underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  8. Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source

    Directory of Open Access Journals (Sweden)

    Barlanka Ravikumar

    2012-01-01

    Full Text Available In Brachytherapy treatment planning, the effects of tissue heterogeneities are commonly neglected due to lack of accurate, general and fast three-dimensional (3D dose-computational algorithms. In performing dose calculations, it is assumed that the tumor and surrounding tissues constitute a uniform, homogeneous medium equivalent to water. In the recent past, three-dimensional computed tomography (3D-CT based treatment planning for Brachytherapy applications has been popularly adopted. However, most of the current commercially available planning systems do not provide the heterogeneity corrections for Brachytherapy dosimetry. In the present study, we have measured and quantified the impact of inhomogeneity caused by different tissues with a 0.015 cc ion chamber. Measurements were carried out in wax phantom which was employed to measure the heterogeneity. Iridium-192 (192 Ir source from high dose rate (HDR Brachytherapy machine was used as the radiation source. The reduction of dose due to tissue inhomogeneity was measured as the ratio of dose measured with different types of inhomogeneity (bone, spleen, liver, muscle and lung to dose measured with homogeneous medium for different distances. It was observed that different tissues attenuate differently, with bone tissue showing maximum attenuation value and lung tissue resulting minimum value and rest of the tissues giving values lying in between those of bone and lung. It was also found that inhomogeneity at short distance is considerably more than that at larger distances.

  9. The dosimetric characteristics of personal alarm dosimeter : Dependence of dose rate and photon energy

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Ha-Seok; Lee, Jun Hee; Kim, Jae Min; Song, Gi Chang; Park, Jae Duck [Iljin Radiation Engineering Co. Ltd., Hwaseong (Korea, Republic of)

    2015-10-15

    There is a need to accurately measure the radiation dose. The dosimeters such as TLD(main dosimeter) are cumulative personal dosimeter to be measured after the radiation exposure, not provide information in real-time personal dose. Therefore, active dosimeter such as electronic personal dosimeters have used together as an alternative dosimeter to manage radiation dose of worker in the work place. We have developed and produced electronic personal dosimeters using photo diode as a detector(Model name: CLOVER), have also programmed the dose calculating algorithms to fit this dosimeter. We have developed and produced electronic personal dosimeters using photo diode as a detector, have also programmed the dose calculating algorithms to fit this dosimeter. The result of tests to meet in KS C IEC 61526 requirements for this dosimeter could obtain the following conclusions. 3.1. The relative intrinsic error and the dependence of dose equivalent rate of this electronic dosimeter are not exceed 20%, and meet with requirements. 3.2. The dependence of energy in the low energy region is exceeded 30%.

  10. Frequency-locked pulse sequencer for high-frame-rate monochromatic tissue motion imaging.

    Science.gov (United States)

    Azar, Reza Zahiri; Baghani, Ali; Salcudean, Septimiu E; Rohling, Robert

    2011-04-01

    To overcome the inherent low frame rate of conventional ultrasound, we have previously presented a system that can be implemented on conventional ultrasound scanners for high-frame-rate imaging of monochromatic tissue motion. The system employs a sector subdivision technique in the sequencer to increase the acquisition rate. To eliminate the delays introduced during data acquisition, a motion phase correction algorithm has also been introduced to create in-phase displacement images. Previous experimental results from tissue- mimicking phantoms showed that the system can achieve effective frame rates of up to a few kilohertz on conventional ultrasound systems. In this short communication, we present a new pulse sequencing strategy that facilitates high-frame-rate imaging of monochromatic motion such that the acquired echo signals are inherently in-phase. The sequencer uses the knowledge of the excitation frequency to synchronize the acquisition of the entire imaging plane to that of an external exciter. This sequencing approach eliminates any need for synchronization or phase correction and has applications in tissue elastography, which we demonstrate with tissue-mimicking phantoms.

  11. EURISOL Multi-MW Target Station - MAFF Configuration - Neutron Fluxes, Fission Rates, Dose Rates and Activation

    CERN Document Server

    Luis, R; Goncalves, I. F; Vaz, P; Kadi, Y; Kharoua, C; Rocca, R; Bermudez, J; Tecchio, L; Negoita, F; Ene, D; David, J.C

    The EURISOL (The EURopean Isotope Separation On-Line Radioactive Ion Beam) project aims atproducing high intensity radioactive ion beams produced by neutron-induced fission on fissile targets(235U) surrounding a liquid mercury converter. A proton beam of 1GeV and 4MW impinges on theconverter, generating, by spallation reactions, high neutron fluxes that induce fission in thesurrounding fissile targets.In this work the state-of-the-art Monte Carlo codes MCNPX and FLUKA were used to assess theneutronics performance of the system, which geometry, inspired in the MAFF concept, allows aversatile manipulation of the fission targets. The first objective of the study was to optimize thegeometry and the materials used in the fuel and reflector elements of the system, in order to achievethe highest possible fission rates. Indeed, it is shown that the appropriate combination of fission targetmaterial and surrounding reflector material leads to the aimed value of 1015 fissions/s per fissiontarget. The second part of this...

  12. Extensive antibiotic prescription rate among hospitalized patients in Uganda: but with frequent missed-dose days

    Science.gov (United States)

    Kiguba, Ronald; Karamagi, Charles; Bird, Sheila M.

    2016-01-01

    Objectives To describe the patterns of systemic antibiotic use and missed-dose days and detail the prescription, dispensing and administration of frequently used hospital-initiated antibiotics among Ugandan inpatients. Methods This was a prospective cohort of consented adult inpatients admitted on the medical and gynaecological wards of the 1790 bed Mulago National Referral Hospital. Results Overall, 79% (603/762; 95% CI: 76%–82%) of inpatients received at least one antibiotic during hospitalization while 39% (300/762; 95% CI: 36%–43%) had used at least one antibiotic in the 4 weeks pre-admission; 1985 antibiotic DDDs, half administered parenterally, were consumed in 3741 inpatient-days. Two-fifths of inpatients who received at least one of the five frequently used hospital-initiated antibiotics (ceftriaxone, metronidazole, ciprofloxacin, amoxicillin and azithromycin) missed at least one antibiotic dose-day (44%, 243/558). The per-day risk of missed antibiotic administration was greatest on day 1: ceftriaxone (36%, 143/398), metronidazole (27%, 67/245), ciprofloxacin (34%, 39/114) and all inpatients who missed at least one dose-day of prescribed amoxicillin and azithromycin. Most patients received fewer doses than were prescribed: ceftriaxone (74%, 273/371), ciprofloxacin (90%, 94/105) and metronidazole (97%, 222/230). Of prescribed doses, only 62% of ceftriaxone doses (1178/1895), 35% of ciprofloxacin doses (396/1130) and 27% of metronidazole doses (1043/3862) were administered. Seven percent (13/188) of patients on intravenous metronidazole and 6% (5/87) on intravenous ciprofloxacin switched to oral route. Conclusions High rates of antibiotic use both pre-admission and during hospitalization were observed, with low parenteral/oral switch of hospital-initiated antibiotics. Underadministration of prescribed antibiotics was common, especially on the day of prescription, risking loss of efficacy and antibiotic resistance. PMID:26945712

  13. Islet Oxygen Consumption Rate (OCR Dose Predicts Insulin Independence in Clinical Islet Autotransplantation.

    Directory of Open Access Journals (Sweden)

    Klearchos K Papas

    Full Text Available Reliable in vitro islet quality assessment assays that can be performed routinely, prospectively, and are able to predict clinical transplant outcomes are needed. In this paper we present data on the utility of an assay based on cellular oxygen consumption rate (OCR in predicting clinical islet autotransplant (IAT insulin independence (II. IAT is an attractive model for evaluating characterization assays regarding their utility in predicting II due to an absence of confounding factors such as immune rejection and immunosuppressant toxicity.Membrane integrity staining (FDA/PI, OCR normalized to DNA (OCR/DNA, islet equivalent (IE and OCR (viable IE normalized to recipient body weight (IE dose and OCR dose, and OCR/DNA normalized to islet size index (ISI were used to characterize autoislet preparations (n = 35. Correlation between pre-IAT islet product characteristics and II was determined using receiver operating characteristic analysis.Preparations that resulted in II had significantly higher OCR dose and IE dose (p<0.001. These islet characterization methods were highly correlated with II at 6-12 months post-IAT (area-under-the-curve (AUC = 0.94 for IE dose and 0.96 for OCR dose. FDA/PI (AUC = 0.49 and OCR/DNA (AUC = 0.58 did not correlate with II. OCR/DNA/ISI may have some utility in predicting outcome (AUC = 0.72.Commonly used assays to determine whether a clinical islet preparation is of high quality prior to transplantation are greatly lacking in sensitivity and specificity. While IE dose is highly predictive, it does not take into account islet cell quality. OCR dose, which takes into consideration both islet cell quality and quantity, may enable a more accurate and prospective evaluation of clinical islet preparations.

  14. The estimation of absorbed dose rates for non-human biota : an extended inter-comparison.

    Energy Technology Data Exchange (ETDEWEB)

    Batlle, J. V. I.; Beaugelin-Seiller, K.; Beresford, N. A.; Copplestone, D.; Horyna, J.; Hosseini, A.; Johansen, M.; Kamboj, S.; Keum, D.-K.; Kurosawa, N.; Newsome, L.; Olyslaegers, G.; Vandenhove, H.; Ryufuku, S.; Lynch, S. V.; Wood, M. D.; Yu, C. (Environmental Science Division); (Westlakes Scientific Consulting Ltd.); (Inst. de Radioprotection et de Surete Nucleaire); (Centre for Ecology & Hydrology); (Norwegian Radiation Protection Authority); (State Office for Nuclear Safety); (Korea Atomic Energy Research Institute); (Visible Information Centre Inc.); (Belgian Nuclear Research Centre); (University of Liverpool)

    2011-05-01

    An exercise to compare 10 approaches for the calculation of unweighted whole-body absorbed dose rates was conducted for 74 radionuclides and five of the ICRP's Reference Animals and Plants, or RAPs (duck, frog, flatfish egg, rat and elongated earthworm), selected for this exercise to cover a range of body sizes, dimensions and exposure scenarios. Results were analysed using a non-parametric method requiring no specific hypotheses about the statistical distribution of data. The obtained unweighted absorbed dose rates for internal exposure compare well between the different approaches, with 70% of the results falling within a range of variation of {+-}20%. The variation is greater for external exposure, although 90% of the estimates are within an order of magnitude of one another. There are some discernible patterns where specific models over- or under-predicted. These are explained based on the methodological differences including number of daughter products included in the calculation of dose rate for a parent nuclide; source-target geometry; databases for discrete energy and yield of radionuclides; rounding errors in integration algorithms; and intrinsic differences in calculation methods. For certain radionuclides, these factors combine to generate systematic variations between approaches. Overall, the technique chosen to interpret the data enabled methodological differences in dosimetry calculations to be quantified and compared, allowing the identification of common issues between different approaches and providing greater assurance on the fundamental dose conversion coefficient approaches used in available models for assessing radiological effects to biota.

  15. RaD-X: Complementary measurements of dose rates at aviation altitudes

    Science.gov (United States)

    Meier, Matthias M.; Matthiä, Daniel; Forkert, Tomas; Wirtz, Michael; Scheibinger, Markus; Hübel, Robert; Mertens, Christopher J.

    2016-09-01

    The RaD-X stratospheric balloon flight organized by the National Aeronautics and Space Administration was launched from Fort Sumner on 25 September 2015 and carried several instruments to measure the radiation field in the upper atmosphere at the average vertical cutoff rigidity Rc of 4.1 GV. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt) in cooperation with Lufthansa German Airlines supported this campaign with an independent measuring flight at the altitudes of civil aviation on a round trip from Germany to Japan. The goal was to measure dose rates under similar space weather conditions over an area on the Northern Hemisphere opposite to the RaD-X flight. Dose rates were measured in the target areas, i.e., around vertical cutoff rigidity Rc of 4.1 GV, at two flight altitudes for about 1 h at each position with acceptable counting statistics. The analysis of the space weather situation during the flights shows that measuring data were acquired under stable and moderate space weather conditions with a virtually undisturbed magnetosphere. The measured rates of absorbed dose in silicon and ambient dose equivalent complement the data recorded during the balloon flight. The combined measurements provide a set of experimental data suitable for validating and improving numerical models for the calculation of radiation exposure at aviation altitudes.

  16. Simulation of In-Core Dose Rates for an Offline CANDU Reactor

    Science.gov (United States)

    Gilbert, Jordan

    This thesis describes the development of a Monte Carlo simulation to predict the dose rates that will be encountered by a novel robotic inspection system for the pressure tubes of an offline CANDU reactor. Simulations were performed using the Monte Carlo N-Particle (MCNP) radiation transport code, version 6.1. The radiation fields within the reactor, even when shut down, are very high, and can cause significant damage to certain structural components and the electronics of the inspection system. Given that the robotic system will rely heavily on electronics, it is important to know the dose rates that will be encountered, in order to estimate the component lifetimes. The MCNP simulation was developed and benchmarked against information obtained from Ontario Power Generation and the Canadian Nuclear Laboratories. The benchmarking showed a good match between the simulated values and the expected values. This simulation, coupled with the accompanying user interface, represent a tool in dose field prediction that is currently unavailable. Predicted dose rates for a postulated inspection at 7 days after shutdown, with 2:5 cm of tungsten shielding around the key components, would survive for approximately 7 hours in core. This is anticipated to be enough time to perform an inspection and shows that the use of this tool can aid in designing the new inspection system.

  17. Interstitial pneumonitis following total body irradiation for bone marrow transplantation using two different dose rates

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T.H.; Rybka, W.B.; Lehnert, S.; Podgorsak, E.B.; Freeman, C.R.

    1985-07-01

    A total of 22 patients with leukemia have undergone allogeneic bone marrow transplantation (BMT) by the Quebec Co-operative Group for Marrow Transplantation from 1980 to 1982. All patients received 900 cGy total body irradiation (TBI), in a single fraction, on the day preceding BMT. The first 11 patients were treated on a cobalt unit at a constant dose rate of 4.7 to 6.3 cGy/min. Six of these patients developed interstitial pneumonitis (IP). The clinical course of three patients, two with idiopathic and one with drug-induced pneumonitis, was mild and recovery was complete in all. The other three patients developed severe infectious IP and two died. The next 11 patients were treated with a sweeping beam technique on a 4 MV linear accelerator delivering a total tumor dose of 900 cGy at an average dose rate of 6.0 to 6.5 cGy/min but an instantaneous dose rate of 21.0 to 23.5 cGy/min. Eight patients developed severe IP. Five of these were idiopathic and four died. Three were infectious and all died. The fatality of interstitial pneumonitis appeared to be greater in the group treated with the sweeping beam technique.

  18. The effects of low dose rate irradiation and thermal aging on reactor structural alloys

    Science.gov (United States)

    Allen, T. R.; Trybus, C. L.; Cole, J. I.

    As part of the EBR-II reactor materials surveillance program, test samples of fifteen different alloys were placed into EBR-II in 1965. The surveillance (SURV) program was intended to determine property changes in reactor structural materials caused by irradiation and thermal aging. In this work, the effect of low dose rate (approximately 2 × 10 -8 dpa/s) irradiation at 380-410°C and long term thermal aging at 371°C on the properties of 20% cold worked 304 stainless steel, 420 stainless steel, Inconel X750, 304/308 stainless weld material, and 17-4 PH steel are evaluated. Doses of up to 6.8 dpa and thermal aging to 2994 days did not significantly affect the density of these alloys. The strength of 304 SS, X750, 17-4 PH, and 304/308 weld material increased with irradiation. In contrast, the strength of 420 stainless steel decreased with irradiation. Irradiation decreased the impact energy in both Inconel X750 and 17-4 PH steel. Thermal aging decreased the impact energy in 17-4 PH steel and increased the impact energy in Inconel X750. Tensile property comparisons of 304 SURV samples with 304 samples irradiated in EBR-II at a higher dose rate show that the higher dose rate samples had greater increases in strength and greater losses in ductility.

  19. A single dose of dark chocolate increases parasympathetic modulation and heart rate variability in healthy subjects

    Directory of Open Access Journals (Sweden)

    Ana Amélia Machado DUARTE

    Full Text Available ABSTRACT Objective: The aim of this study was to investigate the acute effect of a single dose of dark chocolate (70% cocoa on blood pressure and heart rate variability. Methods: Thirty-one healthy subjects (aged 18-25 years; both sexes were divided into two groups: 10 subjects in the white chocolate (7.4 g group and 21 in the dark chocolate (10 g group; measurements were performed at the university's physiology lab. An electrocardiogram measured the sympathovagal balance by spectral and symbolic analysis. Results: A single dose of dark chocolate significantly reduced systolic blood pressure and heart rate. After consuming 10 g of dark chocolate, significant increases were observed for heart rate variability, standard deviation of RR intervals standard deviation of all NN intervals, square root of the mean squared differences between adjacent normal RR intervals root mean square of successive differences, and an increase in the high frequency component in absolute values, representing the parasympathetic modulation. Conclusion: In conclusion the importance of our results lies in the magnitude of the response provoked by a single dose of cocoa. Just 10 g of cocoa triggered a significant increase in parasympathetic modulation and heart rate variability. These combined effects can potentially increase life expectancy because a reduction in heart rate variability is associated with several cardiovascular diseases and higher mortality.

  20. Evaluation of induced activity, decay heat and dose rate distribution after shutdown in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Maki, Koichi [Hitachi Ltd., Ibaraki (Japan). Hitachi Research Lab.; Satoh, Satoshi; Hayashi, Katsumi; Yamada, Koubun; Takatsu, Hideyuki; Iida, Hiromasa

    1997-03-01

    Induced activity, decay heat and dose rate distributions after shutdown were estimated for 1MWa/m{sup 2} operation in ITER. The activity in the inboard blanket one day after shutdown is 1.5x10{sup 11}Bq/cm{sup 3}, and the average decay heating rate 0.01w/cm{sup 3}. The dose rate outside the 120cm thick concrete biological shield is two order higher than the design criterion of 5{mu}Sv/h. This indicates that the biological shield thickness should be enhanced by 50cm in concrete, that is, total thickness 170cm for workers to enter the reactor room and to perform maintenance. (author)

  1. Idiorrhythmic dose-rate variability in dietary zinc intake generates a different response pattern of zinc metabolism than conventional dose-response feeding.

    Science.gov (United States)

    Momcilović, B; Reeves, P G; Blake, M J

    1997-07-01

    We compared the effects of idiorrhythmic dose-rate feeding and conventional dose-response on the induction of intestinal metallothionein (iMT), expression of aortal heat-shock protein mRNA (HSP70mRNA) induced by restraint stress, and accumulation of Zn in the femur and incisor of young growing male rats. An idiorrhythmic approach requires that the average dietary Zn concentration (modulo, M) over the whole experiment (epoch, E) is kept constant across different groups. This is done by adjusting the Zn concentration of the supplemented diet supplied to compensate for the reduction in the number of days on which Zn-supplemented diet is fed, the latter being spread evenly over the experiment. Idiorrhythms involve offering the diet with n times the overall Zn concentration (M) only every nth day with Zn-deficient diet offered on other days. Idiorrythmic Zn dose-rate feeding changed Zn accumulation in the femur and incisor in a complex bi-modal fashion, indicating that metabolic efficiency of dietary Zn is not constant but depends on Zn dose-rate. In contrast to feeding Zn in the conventional dose-response scheme, iMT and HSP70mRNA were not affected by idiorrhythmic dose-rate feeding. Idiorrhythmic cycling in dietary Zn load posed no risk of a biochemical overload nor caused the animals to be stressed. Idiorrhythmic dose-rate feeding brings the dimension of time to the conventional dose-response model.

  2. Improving detection of obstructive sleep apnoea by overnight oximetry in children using pulse rate parameters.

    Science.gov (United States)

    Sahadan, Dg Zuraini; Davey, Margot J; Horne, Rosemary S C; Nixon, Gillian M

    2015-12-01

    Overnight oximetry is a simple tool for investigation of obstructive sleep apnoea (OSA) in children, but only severe cases will be detected, and children with obstructive events resulting in arousal, but not desaturation, will have a normal (inconclusive) result. We hypothesised that pulse rate rises using pulse rate indices per hour (PRI) and pulse rate standard deviation (PR-SD) automatically calculated from commercially available software would improve oximetry as a diagnostic tool. Children having home overnight oximetry for suspected OSA were identified over 12 months, and those with a normal result who went on to have polysomnography (PSG) were included. Oximetry, including PR-SD and PRI (rises of 8, 10 and 15 beats/min per hour), was analyzed using commercially available software. PR parameters were compared between those with OSA (obstructive apnoea-hypopnoea index (OAHI) >1 event/h) and those without OSA. One hundred sixteen children had normal oximetry, of whom 93 (median age 4.5 years; 55 % M) had PSG. Fifty-seven of 93 (61 %) children had OSA (median OAHI 4.5 events/h, range 1.1-24). PR-SD was not different between the OSA and non-OSA groups (p = 0.87). PRI tended to be higher in those with OSA, but there was considerable overlap between the groups: PRI-8 (mean ± SD 58.5 ± 29.0/h in OSA group vs 48.6 ± 20.2/h in non-OSA group, p = 0.07), PRI-10 (45.1 ± 25.0 vs 36.2 ± 16.7, p = 0.06) and PRI-15 (24.4 ± 14.5 vs 18.9 ± 9.0, p = 0.04). A PRI-15 threshold of >35/h had specificity of 97 % for OSA. The PRI-15 shows promise as an indicator of OSA in children with normal oximetry.

  3. Analysis of high–dose rate brachytherapy dose distribution resemblance in CyberKnife hypofractionated treatment plans of localized prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sudahar, H., E-mail: h.sudahar@gmail.com [Department of Radiotherapy, Apollo Speciality Hospital, Chennai (India); Kurup, P.G.G.; Murali, V.; Mahadev, P. [Department of Radiotherapy, Apollo Speciality Hospital, Chennai (India); Velmurugan, J. [Department of Medical Physics, Anna University, Chennai (India)

    2013-01-01

    The present study is to analyze the CyberKnife hypofractionated dose distribution of localized prostate cancer in terms of high–dose rate (HDR) brachytherapy equivalent doses to assess the degree of HDR brachytherapy resemblance of CyberKnife dose distribution. Thirteen randomly selected localized prostate cancer cases treated using CyberKnife with a dose regimen of 36.25 Gy in 5 fractions were considered. HDR equivalent doses were calculated for 30 Gy in 3 fractions of HDR brachytherapy regimen. The D{sub 5%} of the target in the CyberKnife hypofractionation was 41.57 ± 2.41 Gy. The corresponding HDR fractionation (3 fractions) equivalent dose was 32.81 ± 1.86 Gy. The mean HDR fractionation equivalent dose, D{sub 98%}, was 27.93 ± 0.84 Gy. The V{sub 100%} of the prostate target was 95.57% ± 3.47%. The V{sub 100%} of the bladder and the rectum were 717.16 and 79.6 mm{sup 3}, respectively. Analysis of the HDR equivalent dose of CyberKnife dose distribution indicates a comparable resemblance to HDR dose distribution in the peripheral target doses (D{sub 98%} to D{sub 80%}) reported in the literature. However, there is a substantial difference observed in the core high-dose regions especially in D{sub 10%} and D{sub 5%}. The dose fall-off within the OAR is also superior in reported HDR dose distribution than the HDR equivalent doses of CyberKnife.

  4. Pulsed dose rate (PDR) brachytherapy as salvage treatment of locally advanced or recurrent gynecologic cancer

    DEFF Research Database (Denmark)

    Jensen, P T; Roed, H; Engelholm, S A

    1998-01-01

    . There was no difference in survival probability when stratifying the patients by primary diagnosis (recurrent vs. primary advanced), relapse locations (central vs. central + pelvic wall mass) or treatment volume. Seventeen chronic grade III complications were observed in 10 patients. Large treatment volumes significantly...

  5. The effect of workplace smoking bans on heart rate variability and pulse wave velocity of non-smoking hospitality workers.

    Science.gov (United States)

    Rajkumar, Sarah; Schmidt-Trucksäss, Arno; Wellenius, Gregory A; Bauer, Georg F; Huynh, Cong Khanh; Moeller, Alexander; Röösli, Martin

    2014-08-01

    To investigate the effect of a change in second-hand smoke (SHS) exposure on heart rate variability (HRV) and pulse wave velocity (PWV), this study utilized a quasi-experimental setting when a smoking ban was introduced. HRV, a quantitative marker of autonomic activity of the nervous system, and PWV, a marker of arterial stiffness, were measured in 55 non-smoking hospitality workers before and 3-12 months after a smoking ban and compared to a control group that did not experience an exposure change. SHS exposure was determined with a nicotine-specific badge and expressed as inhaled cigarette equivalents per day (CE/d). PWV and HRV parameters significantly changed in a dose-dependent manner in the intervention group as compared to the control group. A one CE/d decrease was associated with a 2.3% (95% CI 0.2-4.4; p = 0.031) higher root mean square of successive differences (RMSSD), a 5.7% (95% CI 0.9-10.2; p = 0.02) higher high-frequency component and a 0.72% (95% CI 0.40-1.05; p < 0.001) lower PWV. PWV and HRV significantly improved after introducing smoke-free workplaces indicating a decreased cardiovascular risk.

  6. Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer

    OpenAIRE

    2015-01-01

    Purpose In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative s...

  7. The influence of the repetition rate on the nanosecond pulsed pin-to-pin microdischarges

    Science.gov (United States)

    Huang, Bang-Dou; Takashima, Keisuke; Zhu, Xi-Ming; Pu, Yi-Kang

    2014-10-01

    The effect of repetition rate on a nanosecond atmospheric pressure discharge is investigated. The discharge is generated between two pins in a mixture of Ne and Ar. The voltage, current, power waveforms and the temporally and spatially resolved electron density and an ‘effective’ electron temperature are measured, with a pulse interval between 1.5 and 200 µs. It is found that not only does the repetition rate have a strong influence on the breakdown voltage and the peak discharge power, but it can also affect the rise rate of the volume averaged electron density and its peak value. Temporally and spatially resolved measurement of the electron density and the effective electron temperature show that the spatial distributions of both quantities are also influenced by the repetition rate. In the initial discharge period of all cases, the sharp rise of the electron density correlates with the drastic drop of the effective electron temperature. It is suggested that the residual charges have a strong impact on the axial distribution of the electric field and energetic electrons between the electrodes during the breakdown period, as illustrated by a simple sheath model.

  8. Optimization of pulsed DC PACVD parameters: Toward reducing wear rate of the DLC films

    Science.gov (United States)

    Ebrahimi, Mansoureh; Mahboubi, Farzad; Naimi-Jamal, M. Reza

    2016-12-01

    The effect of pulsed direct current (DC) plasma-assisted chemical vapor deposition (PACVD) parameters such as temperature, duty cycle, hydrogen flow, and argon/CH4 flow ratio on the wear behavior and wear durability of the diamond-like carbon (DLC) films was studied by using response surface methodology (RSM). DLC films were deposited on nitrocarburized AISI 4140 steel. Wear rate and wear durability of the DLC films were examined with the pin-on-disk method. Field emission scanning electron microscopy, Raman spectroscopy, and nanoindentation techniques were used for studying wear mechanisms, chemical structure, and hardness of the DLC films. RSM results show that duty cycle is one of the important parameters that affect the wear rate of the DLC samples. The wear rate of the samples deposited with a duty cycle of >75% decreases with an increase in the argon/CH4 ratio. In contrast, for a duty cycle of <65%, the wear rate increases with an increase in the argon/CH4 ratio. The wear durability of the DLC samples increases with an increase in the duty cycle, hydrogen flow, and argon/CH4 flow ratio at the deposition temperature between 85 °C and 110 °C. Oxidation, fatigue, abrasive wear, and graphitization are the wear mechanisms observed on the wear scar of the DLC samples deposited with the optimum deposition conditions.

  9. Interrelation of exposure and exposure rate in germinating seeds of barley and its concurrence with dose-rate theory

    Energy Technology Data Exchange (ETDEWEB)

    Bottino, P.J.; Sparrow, A.H.; Schwemmer, S.S.; Thompson, K.H.

    1975-01-01

    Germinating seeds of barley were irradiated with /sup 137/Cs gamma rays at various combinations of total exposure (400-3200 R) and exposure rate (30-24,000 R/hr). Seedling height was measured 5 days after the initiation of irradiation and the various levels of growth inhibition produced by each combination of treatments were determined. The results obtained ranged from no effect on growth to 100 percent growth inhibition. Growth inhibition curves based on both total exposure and exposure rate were constructed. The exposures required to produce 20 and 35 percent growth inhibition at each exposure rate were determined, 35 percent growth inhibition being the highest level that could be determined over the entire range of rates used (20 percent growth inhibition was used for comparative purposes). For both levels of growth inhibition, as exposure rate increased (or, concomitantly, as exposure time decreased), the total exposure required to produce the end point decreased (effectiveness increased) as a straight line relationship on a double logarithmic plot between 30 and 1500 R/hr (0.03 to 0.3 hr exposure time). Above 1500 R/hr, further increases in exposure rate (or decreases in exposure time) increased the total exposure required for a given effect, i.e., effectiveness decreased. Conversion of exposure rate to exposure time demonstrates this point of change in effectiveness to occur well within one mitotic cycle. These results are discussed with regard to current dose-rate theory and are at least partially consistent therewith. A straight-line dependency of the exposure rate producing maximum growth inhibition on total exposure is shown. The point at which the combinations of exposure and exposure rate for 35 percent growth inhibition occurs is restricted to barley and may differ for other species. This may depend on chromosome size or DNA content and/or the mitotic cycle time characteristic of a species. (auth)

  10. The Dose Rate Dependence of the Yield of Trapped Electrons in Crystalline Ice

    DEFF Research Database (Denmark)

    Nilsson, Johan Daniel Göran; Pagsberg, Palle Bjørn

    1980-01-01

    for the experimental dose rate dependence observed at −10° C. The reaction with the protons has a negative temperature coefficient while the reaction with the OH radicals has an activation energy of about 14 kcal mole−1. The mobility of the proton was estimated to be about 3 × 10−4 cm2 V−1 S−1 at −10°C.......The yield of localized excess electrons in crystalline H2O ice has been studied as a function of the dose rate at various temperatures in the range −10 to −40°C. The G value was found to decrease significantly with increasing dose rate. Thus it appears that the localization of electrons takes place...... in competition with other reactions and we propose a simple model where we assume that the mobile electrons can undergo bimolecular bulk reactions with protons and OH radicals. Rate constants of 3.0 × 1015 M−1 S−1 and 1.4 × 1014 M−1 S−1 for the two reactions were required in the model in order to account...

  11. Optical breakdown and filamentation of femtosecond laser pulses propagating in air at a kHz repetition rate

    Institute of Scientific and Technical Information of China (English)

    Duan Zuo-Liang; Chen Jian-Ping; Li Ru-Xin; Lin Li-Huang; Xu Zhi-Zhan

    2004-01-01

    We report the experiments on the optical breakdown and filamentation of femtosecond laser pulses propagating in air at a kHz repetition rate and with several hundreds micro-joule-energy. A 10m-long filament and its breakup and merging at the nonlinear focal region produced by modulational instability of femtosecond laser pulses in air are observed. A simple model based on the nonlinear Schrodinger equation coupled with multiphoton ionization law is presented to explain the several experimental results.

  12. Picosecond optical pulse generation at gigahertz rates by direct modulation of a semiconductor laser

    Science.gov (United States)

    Auyeung, J.

    1981-01-01

    We report the generation of picosecond pulses by the direct modulation of a buried heterostructure GaAlAs diode laser. Pulse width of 28 ps is achieved at a repetition frequency of 2.5 GHz. Pulse width dependence on the experimental parameters is described.

  13. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

    Science.gov (United States)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-06-01

    In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for (60)Co and 1 mm for both (192)Ir and (169)Yb. Transmission data for (60)Co and (192)Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898-4906) for brachytherapy facility shielding; for (169)Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified.

  14. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  15. A Phase I-II dose escalation study of fixed-dose rate gemcitabine, oxaliplatin and capecitabine every two weeks in advanced cholangiocarcinomas

    DEFF Research Database (Denmark)

    Lassen, Ulrik; Jensen, Lars Henrik; Sorensen, Morten;

    2011-01-01

    Gemcitabine based regimens have been widely used in patients with advanced cholangiocarcinoma (CC), but no standard therapy exists. In this study we aimed to find the maximally tolerated dose (MTD) of a two-week schedule of fixed dose rate (FDR) gemcitabine (G), oxaliplatin (O) and capecitabine (...

  16. High dose rate brachytherapy in early stage squamous-cell carcinoma of the lip.

    Science.gov (United States)

    Mut, Alejandro; Guinot, José Luis; Arribas, Leoncio; Díez-Presa, Lorena; Tortajada, María Isabel; Santos, Miguel Ángel; Samper, Josefa; Santamaría, Paula; Vendrell, Juan Bosco

    2016-01-01

    To analyze the results obtained after treatment of early stage (T1-T2) squamous cell carcinoma of the lip with high dose rate brachytherapy and evaluate the efficacy of this treatment in both local and regional control. Retrospective analysis of the treatments performed at our department from March 1999 to March 2013 with high dose rate brachytherapy with rigid needles. We included 68 patients, 63 men and 5 women; 37 patients (54.4%) presented a T1 tumour, less than or equal to 2cm, while the other 31 (45.6%) were classified as T2. Median total dose was 45Gy, with a median dose per fraction of 5Gy x 9 fractions twice a day for 5 days. With a mean follow-up of 56.4 months, local control was 96.9%. Stratifying by tumour size, local control of T1 cases was 100%, while T2 achieved 93.2% (2 local recurrences). Regional control at 5 years was 93.8% for T1, and 80.8% for T2. In 11 cases with elective cervical treatment, no regional failure happened. As for toxicity, no patient presented soft tissue, or bone, necrosis. All patients achieved good or excellent cosmetic and functional results. High dose rate brachytherapy allows effective, safe treatments for squamous cell carcinoma of the lip, with good aesthetic and functional results. It can be considered a valid alternative for surgery in early stage tumours. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  17. Effects of radiation types and dose rates on selected cable-insulating materials

    Science.gov (United States)

    Hanisch, F.; Maier, P.; Okada, S.; Schönbacher, H.

    A series of radiation tests have been carried out on halogen-free cable-insulating and cable-sheathing materials comprising commercial LDPE, EPR, EVA and SIR compounds. samples were irradiated at five different radiation sources, e.g. a nuclear reactor, fuel elements, a 60Co source, and in the stray radiation field of high-energy proton and electron accelerators at CERN and DESY. The integrated doses were within 50-5000 kGy and the dose rates within 10 mGy/s-70 Gy/s. Tensile tests and gel-fraction measurements were carried out. The results confirm that LDPEs are very sensitive to long-term ageing effects, and that important errors exceeding an order of magnitude can be made when assessing radiation damage by accelerated tests. On the other hand, well-stabilized LDPEs and the cross-linked rubber compounds do not show large dose-rate effects for the values given above. Furthermore, the interpretation of the elongation-at-break data and their relation to gel-fraction measurements show that radiation damage is related to the total absorbed dose irrespective of the different radiation types used in this experiment.

  18. Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

    Energy Technology Data Exchange (ETDEWEB)

    Gay, H A [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Allison, R R [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Downie, G H [Section of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Mota, H C [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Austerlitz, C [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Jenkins, T [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Sibata, C H [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States)

    2007-06-07

    A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed.

  19. The dose rate observed on 19-21 October 1989 and its modulation by geophysical effects.

    Science.gov (United States)

    Smart, D F; Shea, M A; Dachev TsP; Bankov, N G; Petrov, V M; Bengin, V V

    1994-10-01

    The Liulin dosimeter-radiometer on the MIR space station detected the 19 October 1989 high energy solar proton event. These results show that the main particle increase contains protons with energies up to about 9 GeV. After the main particle onset the Liulin dosimeter observed a typical geomagnetic cutoff modulation of the dose rate from the solar particles as the MIR space station traversed magnetic latitudes. When the interplanetary shock and associated solar plasma enveloped the earth on 20 October between 14 and 17 UT the radiation exposure increased significantly due to the lowering of the geomagnetic cutoff. The analysis of this event shows how various geophysical phenomena can significantly modulate the dose rate encountered by earth-orbiting spacecraft.

  20. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  1. Use of silicon photodiode optically connected to scintillator in measurement of gamma dose rates

    Energy Technology Data Exchange (ETDEWEB)

    Gilar, O. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky); Petr, I. (Ceske Vysoke Uceni Technicke, Prague (Czechoslovakia). Fakulta Jaderna a Fysikalne Inzenyrska)

    1984-06-01

    Contributing to the signal which is produced in the photodiode by direct interaction with radiation may also be light photons produced by scintillation in the scintillator which is in optical contact with the photodiode. The scintillator/photodiode combination may increase sensitivity in comparison with the photodiode alone. The energy dependence of the detector will change according to the scintillator material and size. The configuration is described of a detector with CsI(Tl) scintillator. The detector is suitable for medium and large dose rates, the limiting factor for measuring small dose rates is the intensity of the photodiode dark current and its temperature dependence. A higher sensitivity of the designed detector configuration may be achieved by selecting a scintillator with a more suitable emission spectrum or by technological modifications of the photodiode.

  2. Open-source hardware and software and web application for gamma dose rate network operation.

    Science.gov (United States)

    Luff, R; Zähringer, M; Harms, W; Bleher, M; Prommer, B; Stöhlker, U

    2014-08-01

    The German Federal Office for Radiation Protection operates a network of about 1800 gamma dose rate stations as a part of the national emergency preparedness plan. Each of the six network centres is capable of operating the network alone. Most of the used hardware and software have been developed in-house under open-source license. Short development cycles and close cooperation between developers and users ensure robustness, transparency and fast maintenance procedures, thus avoiding unnecessary complex solutions. This also reduces the overall costs of the network operation. An easy-to-expand web interface has been developed to make the complete system available to other interested network operators in order to increase cooperation between different countries. The interface is also regularly in use for education during scholarships of trainees supported, e.g. by the 'International Atomic Energy Agency' to operate a local area dose rate monitoring test network.

  3. Effect of dose rate and multiple fractions per day on radiation-induced lung damage in mice

    Energy Technology Data Exchange (ETDEWEB)

    Collis, C.H.; Down, J.D. (Institute of Cancer Research, Sutton (UK). Surrey Branch)

    1984-11-01

    Acute single and fractionated exposures were carried out at a fixed dose rate, 1 Gy min/sup -1/, and exposure times therefore ranged from 10 to 28 min. For low dose-rate continuous irradiation, the overall treatment time (2, 4 or 8 h) was kept constant and the various test doses obtained by varying the dose rate. Rates ranged from 11.7 to 18.3 cGy min/sup -1/ for the 2-h exposure, from 6.7 to 11.7 cGy min/sup -1/ for the 4-h exposure, and from 3.7 to 6.7 cGy min/sup -1/ for the 8-h exposure. Results confirmed (a) the marked dose-sparing effect of fractionation even over short time intervals, and (b) that still greater sparing is obtained by low dose-rate irradiation.

  4. High-dose rate brachytherapy in the treatment of cancer of the cervix uteri

    Directory of Open Access Journals (Sweden)

    D. A. Aliyev

    2011-01-01

    Full Text Available Analysis of the results of examining and treating 246 patients with Stages IIA-IIIB cancer of the cervix uteri (CCU, receiving specific chemoradiotherapy (CRT at the Department of Radiotherapy, National Oncology Center (Baku, has ascertained that CRT using two high-dose (9 Gy rate brachytherapy fractions and competitive cisplatin chemotherapy is an effective, reasonably safe, and economically sound treatment method for locally advanced CCU. The method shows acceptable toxicity and may be used in routine clinical practice.

  5. The effect of low dose rate on metabolomic response to radiation in mice

    Energy Technology Data Exchange (ETDEWEB)

    Goudarzi, Maryam [Georgetown University, Biochemistry and Molecular and Cellular Biology, Washington, DC (United States); Mak, Tytus D. [Georgetown University, Lombardi Comprehensive Cancer Center, Washington, DC (United States); Chen, Congju; Smilenov, Lubomir B.; Brenner, David J. [Columbia University, Center for High-Throughput Minimally-Invasive Radiation Biodosimetry, New York, NY (United States); Fornace, Albert J. [Georgetown University, Biochemistry and Molecular and Cellular Biology, Washington, DC (United States); Georgetown University, Lombardi Comprehensive Cancer Center, Washington, DC (United States)

    2014-11-15

    Metabolomics has been shown to have utility in assessing responses to exposure by ionizing radiation (IR) in easily accessible biofluids such as urine. Most studies to date from our laboratory and others have employed γ-irradiation at relatively high dose rates (HDR), but many environmental exposure scenarios will probably be at relatively low dose rates (LDR). There are well-documented differences in the biologic responses to LDR compared to HDR, so an important question is to assess LDR effects at the metabolomics level. Our study took advantage of a modern mass spectrometry approach in exploring the effects of dose rate on the urinary excretion levels of metabolites 2 days after IR in mice. A wide variety of statistical tools were employed to further focus on metabolites, which showed responses to LDR IR exposure (0.00309 Gy/min) distinguishable from those of HDR. From a total of 709 detected spectral features, more than 100 were determined to be statistically significant when comparing urine from mice irradiated with 1.1 or 4.45 Gy to that of sham-irradiated mice 2 days post-exposure. The results of this study show that LDR and HDR exposures perturb many of the same pathways such as TCA cycle and fatty acid metabolism, which also have been implicated in our previous IR studies. However, it is important to note that dose rate did affect the levels of particular metabolites. Differences in urinary excretion levels of such metabolites could potentially be used to assess an individual's exposure in a radiobiological event and thus would have utility for both triage and injury assessment. (orig.)

  6. Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy

    OpenAIRE

    Feras Sendy; Eman AlShehri; Amani AlAjmi; Elham Bamanie; Surekha Appani; Taghreed Shams

    2015-01-01

    Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in th...

  7. Individual external dose monitoring of all citizens of Date City by passive dosimeter 5 to 51 months after the Fukushima NPP accident (series): 1. Comparison of individual dose with ambient dose rate monitored by aircraft surveys.

    Science.gov (United States)

    Miyazaki, Makoto; Hayano, Ryugo

    2016-12-06

    Date (da'te) City in Fukushima Prefecture has conducted a population-wide individual dose monitoring program after the Fukushima Daiichi Nuclear Power Plant Accident, which provides a unique and comprehensive data set of the individual doses of citizens. The purpose of this paper, the first in the series, is to establish a method for estimating effective doses based on the available ambient dose rate survey data. We thus examined the relationship between the individual external doses and the corresponding ambient doses assessed from airborne surveys. The results show that the individual doses were about 0.15 times the ambient doses, the coefficient of 0.15 being a factor of 4 smaller than the value employed by the Japanese government, throughout the period of the airborne surveys used. The method obtained in this study could aid in the prediction of individual doses in the early phase of future radiological accidents involving large-scale contamination.

  8. Turnover rates in microorganisms by laser ablation electrospray ionization mass spectrometry and pulse-chase analysis

    Energy Technology Data Exchange (ETDEWEB)

    Stopka, Sylwia A.; Mansour, Tarek R.; Shrestha, Bindesh [Department of Chemistry, W.M. Keck Institute for Proteomics Technology and Applications, The George Washington University, Washington, DC 20052 (United States); Maréchal, Éric; Falconet, Denis [Laboratoire de Physiologie Cellulaire et Végétale, UMR 5168, CEA-CNRS-INRA-Univ. Grenoble Alpes, Grenoble (France); Vertes, Akos, E-mail: vertes@gwu.edu [Department of Chemistry, W.M. Keck Institute for Proteomics Technology and Applications, The George Washington University, Washington, DC 20052 (United States)

    2016-01-01

    Biochemical processes rely on elaborate networks containing thousands of compounds participating in thousands of reaction. Rapid turnover of diverse metabolites and lipids in an organism is an essential part of homeostasis. It affects energy production and storage, two important processes utilized in bioengineering. Conventional approaches to simultaneously quantify a large number of turnover rates in biological systems are currently not feasible. Here we show that pulse-chase analysis followed by laser ablation electrospray ionization mass spectrometry (LAESI-MS) enable the simultaneous and rapid determination of metabolic turnover rates. The incorporation of ion mobility separation (IMS) allowed an additional dimension of analysis, i.e., the detection and identification of isotopologs based on their collision cross sections. We demonstrated these capabilities by determining metabolite, lipid, and peptide turnover in the photosynthetic green algae, Chlamydomonas reinhardtii, in the presence of {sup 15}N-labeled ammonium chloride as the main nitrogen source. Following the reversal of isotope patterns in the chase phase by LAESI-IMS-MS revealed the turnover rates and half-lives for biochemical species with a wide range of natural concentrations, e.g., chlorophyll metabolites, lipids, and peptides. For example, the half-lives of lyso-DGTS(16:0) and DGTS(18:3/16:0), t{sub 1/2} = 43.6 ± 4.5 h and 47.6 ± 2.2 h, respectively, provided insight into lipid synthesis and degradation in this organism. Within the same experiment, half-lives for chlorophyll a, t{sub 1/2} = 24.1 ± 2.2 h, and a 2.8 kDa peptide, t{sub 1/2} = 10.4 ± 3.6 h, were also determined. - Highlights: • High-throughput pulse-chase analysis using direct sampling of biological cells. • Ion mobility separation for the elucidation of isotopologs. • Identification of isotopologs in difference heat plots of DT vs. m/z. • Simultaneous determination of turnover rates for lipids and

  9. High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    White, Evan C.; Kamrava, Mitchell R.; Demarco, John; Park, Sang-June; Wang, Pin-Chieh; Kayode, Oluwatosin; Steinberg, Michael L. [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States); Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States)

    2013-02-01

    Purpose: We performed a dosimetry analysis to determine how well the goals for clinical target volume coverage, dose homogeneity, and normal tissue dose constraints were achieved with high-dose-rate (HDR) prostate brachytherapy. Methods and Materials: Cumulative dose-volume histograms for 208 consecutively treated HDR prostate brachytherapy implants were analyzed. Planning was based on ultrasound-guided catheter insertion and postoperative CT imaging; the contoured clinical target volume (CTV) was the prostate, a small margin, and the proximal seminal vesicles. Dosimetric parameters analyzed for the CTV were D90, V90, V100, V150, and V200. Dose to the urethra, bladder, bladder balloon, and rectum were evaluated by the dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} of each organ, expressed as a percentage of the prescribed dose. Analysis was stratified according to prostate size. Results: The mean prostate ultrasound volume was 38.7 {+-} 13.4 cm{sup 3} (range: 11.7-108.6 cm{sup 3}). The mean CTV was 75.1 {+-} 20.6 cm{sup 3} (range: 33.4-156.5 cm{sup 3}). The mean D90 was 109.2% {+-} 2.6% (range: 102.3%-118.4%). Ninety-three percent of observed D90 values were between 105 and 115%. The mean V90, V100, V150, and V200 were 99.9% {+-} 0.05%, 99.5% {+-} 0.8%, 25.4% {+-} 4.2%, and 7.8% {+-} 1.4%. The mean dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} for organs at risk were: Urethra: 107.3% {+-} 3.0%, 101.1% {+-} 14.6%, and 47.9% {+-} 34.8%; bladder wall: 79.5% {+-} 5.1%, 69.8% {+-} 4.9%, and 64.3% {+-} 5.0%; bladder balloon: 70.3% {+-} 6.8%, 59.1% {+-} 6.6%, and 52.3% {+-} 6.2%; rectum: 76.3% {+-} 2.5%, 70.2% {+-} 3.3%, and 66.3% {+-} 3.8%. There was no significant difference between D90 and V100 when stratified by prostate size. Conclusions: HDR brachytherapy allows the physician to consistently achieve complete prostate target coverage and maintain normal tissue dose constraints for organs at risk over a wide range of target volumes.

  10. Optimum injection dose rate of hydrogen sulfide scavenger for treatment of petroleum crude oil

    Directory of Open Access Journals (Sweden)

    T.M. Elshiekh

    2016-03-01

    Full Text Available Hydrogen sulfide H2S scavengers are chemicals that favorably react with hydrogen sulfide gas to eliminate it and produce environmental friendly products. These products depend on the type and composition of the scavenger and the conditions at which the reaction takes place. The scavenger should be widely available and economical for industry acceptance by having a low unit cost. The optimum values of H2S scavenger injection dose rate of scavenging hydrogen sulfide from the multiphase fluid produced at different wells conditions in one of the Petroleum Companies in Egypt were studied. The optimum values of H2S scavenger injection dose rate depend on pipe diameter, pipe length, gas molar mass velocity, inlet H2S concentration and pressure. The optimization results are obtained for different values of these parameters using the software program Lingo. In general, the optimum values of H2S scavenger injection dose rate of the scavenging of hydrogen sulfide are increased by increasing of the pipe diameter and increasing the inlet H2S concentration, and decreased by increasing the pipe length, gas molar mass velocity and pressure.

  11. High dose rate endorectal brachytherapy as a neoadjuvant treatment for patients with resectable rectal cancer.

    Science.gov (United States)

    Vuong, T; Devic, S; Podgorsak, E

    2007-11-01

    In the era of total mesorectal surgery, the issue of radiation toxicity is raised. A novel endocavitary brachytherapy technique was tested as a neoadjuvant treatment for patients with resectable rectal cancer. The objectives of the study were to evaluate the treatment-related toxicity and effects on local recurrence. A dose of 26 Gy was prescribed to the gross tumour volume and intramesorectal deposits seen on magnetic resonance imaging and given over four daily treatments, using the high dose rate delivery system followed by surgery 6-8 weeks later. The study included 93 T3, four T4 and three T2 tumours. Acute proctitis of grade 2 was observed in all patients, but one required transfusion. At a median follow-up time of 60 months, the 5-year actual local recurrence rate was 5%, disease-free survival was 65%, and overall survival was 70%. High dose rate endorectal brachytherapy seems to prevent local recurrence and has a favourable toxicity pattern compared with external beam radiotherapy.

  12. Simulation for estimation of hydrogen sulfide scavenger injection dose rate for treatment of crude oil

    Directory of Open Access Journals (Sweden)

    T.M. Elshiekh

    2015-12-01

    Full Text Available The presence of hydrogen sulfide in the hydrocarbon fluids is a well known problem in many oil and gas fields. Hydrogen sulfide is an undesirable contaminant which presents many environmental and safety hazards. It is corrosive, malodorous, and toxic. Accordingly, a need has been long left in the industry to develop a process which can successfully remove hydrogen sulfide from the hydrocarbons or at least reduce its level during the production, storage or processing to a level that satisfies safety and product specification requirements. The common method used to remove or reduce the concentration of hydrogen sulfide in the hydrocarbon production fluids is to inject the hydrogen sulfide scavenger into the hydrocarbon stream. One of the chemicals produced by the Egyptian Petroleum Research Institute (EPRI is EPRI H2S scavenger. It is used in some of the Egyptian petroleum producing companies. The injection dose rate of H2S scavenger is usually determined by experimental lab tests and field trials. In this work, this injection dose rate is mathematically estimated by modeling and simulation of an oil producing field belonging to Petrobel Company in Egypt which uses EPRI H2S scavenger. Comparison between the calculated and practical values of injection dose rate emphasizes the real ability of the proposed equation.

  13. Dose-rate distribution of {sup 32}P-glass microspheres for intra-arterial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Carla C.; Moralles, Mauricio; Sene, Frank F.; Martinelli, Jose R. [Centro de Ciencia e Tecnologia de Materiais, IPEN, Av. Lineu Prestes 2242, Sao Paulo, Sao Paulo 05508-000 (Brazil); Centro do Reator de Pesquisas, Energy and Nuclear Research Institute, IPEN/CNEN, CP 11049, CEP 05422-970, Sao Paulo, Sao Paulo (Brazil); Centro de Ciencia e Tecnologia de Materiais, IPEN, Av. Lineu Prestes 2242, Sao Paulo, Sao Paulo 05508-000 (Brazil)

    2010-02-15

    Purpose: The intra-arterial administration of radioactive glass microspheres is an alternative therapy option for treating primary hepatocellular carcinoma, the main cause of liver cancer death, and metastatic liver cancer, another important kind of cancer induced in the liver. The technique involves the administration of radioactive microspheres in the hepatic artery, which are trapped preferentially in the tumor. Methods: In this work the GEANT4 toolkit was used to calculate the radial dose-rate distributions in water from {sup 32}P-loaded glass microspheres and also from {sup 90}Y-loaded glass microspheres. To validate the toolkit for this application, the authors compared the dose-rate distribution of {sup 32}P and {sup 90}Y point sources in water with data from the International Commission on Radiation Units and Measurements report 72. Results: Tables of radial dose-rate distributions are provided for practical use in brachytherapy planning with these microspheres. Conclusions: The simulations with the microspheres show that the shape of the beta ray energy spectra with respect to the {sup 32}P and {sup 90}Y sources is significantly modified by the glass matrix.

  14. Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil

    CERN Document Server

    Clouvas, A; Antonopoulos-Domis, M; Silva, J

    2000-01-01

    The dose rate conversion factors D/sub CF/ (absorbed dose rate in air per unit activity per unit of soil mass, nGy h/sup -1/ per Bq kg/sup -1/) are calculated 1 m above ground for photon emitters of natural radionuclides uniformly distributed in the soil. Three Monte Carlo codes are used: 1) The MCNP code of Los Alamos; 2) The GEANT code of CERN; and 3) a Monte Carlo code developed in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki. The accuracy of the Monte Carlo results is tested by the comparison of the unscattered flux obtained by the three Monte Carlo codes with an independent straightforward calculation. All codes and particularly the MCNP calculate accurately the absorbed dose rate in air due to the unscattered radiation. For the total radiation (unscattered plus scattered) the D/sub CF/ values calculated from the three codes are in very good agreement between them. The comparison between these results and the results deduced previously by other authors indicates a good ag...

  15. External gamma-ray dose rate and radon concentration in indoor environments covered with Brazilian granites

    Energy Technology Data Exchange (ETDEWEB)

    Anjos, R.M., E-mail: meigikos@if.uff.br [LARA - Laboratorio de Radioecologia, Instituto de Fisica, Universidade Federal Fluminense, Av. Gal Milton Tavares de Souza, s/no, Gragoata, 24210-340 Niteroi, RJ (Brazil); Juri Ayub, J. [LARA - Laboratorio de Radioecologia, Instituto de Fisica, Universidade Federal Fluminense, Av. Gal Milton Tavares de Souza, s/no, Gragoata, 24210-340 Niteroi, RJ (Brazil); GEA-Instituto de Matematica Aplicada San Luis (IMASL), Universidad Nacional de San Luis, Consejo Nacional de Investigaciones Cientificas y Tecnicas, CCT-San Luis, Ej. de los Andes 950, D5700HHW San Luis (Argentina); Cid, A.S.; Cardoso, R.; Lacerda, T. [LARA - Laboratorio de Radioecologia, Instituto de Fisica, Universidade Federal Fluminense, Av. Gal Milton Tavares de Souza, s/no, Gragoata, 24210-340 Niteroi, RJ (Brazil)

    2011-11-15

    Health hazard from natural radioactivity in Brazilian granites, covering the walls and floor in a typical dwelling room, was assessed by indirect methods to predict external gamma-ray dose rates and radon concentrations. The gamma-ray dose rate was estimated by a Monte Carlo simulation method and validated by in-situ measurements with a NaI spectrometer. Activity concentrations of {sup 232}Th, {sup 226}Ra, and {sup 40}K in an extensive selection of Brazilian commercial granite samples measured by using gamma-ray spectrometry were found to be 4.5-450 Bq kg{sup -1}, 4.9-160 Bq kg{sup -1} and 190-2029 Bq kg{sup -1}, respectively. The maximum external gamma-ray dose rate from floor and walls covered with the Brazilian granites in the typical dwelling room (5.0 m x 4.0 m area, 2.8 m height) was found to be 120 nGy h{sup -1}, which is comparable with the average worldwide exposure to external terrestrial radiation of 80 nGy h{sup -1} due to natural sources, proposed by United Nations Scientific Committee on the Effects of Atomic Radiation. Radon concentrations in the room were also estimated by a simple mass balance equation and exhalation rates calculated from the measured values of {sup 226}Ra concentrations and the material properties. The results showed that the radon concentration in the room ventilated adequately (0.5 h{sup -1}) will be lower than 100 Bq m{sup -3}, value recommended as a reference level by the World Health Organization. - Highlights: > We used indirect methods to predict external gamma dose rate and radon concentration. > The gamma-ray dose rate was estimated by a Monte Carlo simulation method. > The results were validated by in-situ measurements with a NaI spectrometer. > Radon concentrations in the room were estimated by a simple mass balance equation. > Radon concentration in the room ventilated adequately will be lower than 100 Bq m{sup -3}.

  16. Relationship between Resting Heart Rate, Blood Pressure and Pulse Pressure in Adolescents.

    Science.gov (United States)

    Christofaro, Diego Giulliano Destro; Casonatto, Juliano; Vanderlei, Luiz Carlos Marques; Cucato, Gabriel Grizzo; Dias, Raphael Mendes Ritti

    2017-05-01

    High resting heart rate is considered an important factor for increasing mortality chance in adults. However, it remains unclear whether the observed associations would remain after adjustment for confounders in adolescents. To analyze the relationship between resting heart rate, blood pressure and pulse pressure in adolescents of both sexes. A cross-sectional study with 1231 adolescents (716 girls and 515 boys) aged 14-17 years. Heart rate, blood pressure and pulse pressure were evaluated using an oscillometric blood pressure device, validated for this population. Weight and height were measured with an electronic scale and a stadiometer, respectively, and waist circumference with a non-elastic tape. Multivariate analysis using linear regression investigated the relationship between resting heart rate and blood pressure and pulse pressure in boys and girls, controlling for general and abdominal obesity. Higher resting heart rate values were observed in girls (80.1 ± 11.0 beats/min) compared to boys (75.9 ± 12.7 beats/min) (p ≤ 0.001). Resting heart rate was associated with systolic blood pressure in boys (Beta = 0.15 [0.04; 0.26]) and girls (Beta = 0.24 [0.16; 0.33]), with diastolic blood pressure in boys (Beta = 0.50 [0.37; 0.64]) and girls (Beta = 0.41 [0.30; 0.53]), and with pulse pressure in boys (Beta = -0.16 [-0.27; -0.04]). This study demonstrated a relationship between elevated resting heart rate and increased systolic and diastolic blood pressure in both sexes and pulse pressure in boys even after controlling for potential confounders, such as general and abdominal obesity. A frequência cardíaca de repouso é considerada um importante fator de aumento de mortalidade em adultos. Entretanto, ainda é incerto se as associações observadas permanecem após ajuste para fatores de confusão em adolescentes. Analisar a relação entre frequência cardíaca de repouso, pressão arterial e pressão de pulso em adolescentes dos dois sexos. Estudo transversal

  17. Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique

    Energy Technology Data Exchange (ETDEWEB)

    Motamedi, Kambiz; Levine, Benjamin D.; Seeger, Leanne L.; McNitt-Gray, Michael F. [UCLA Health System, Radiology, Los Angeles, CA (United States)

    2014-11-15

    To evaluate the success rate of a low-dose (50 % mAs reduction) computed tomography (CT) biopsy technique. This protocol was adopted based on other successful reduced-CT radiation dose protocols in our department, which were implemented in conjunction with quality improvement projects. The technique included a scout view and initial localizing scan with standard dose. Additional scans obtained for further guidance or needle adjustment were acquired by reducing the tube current-time product (mAs) by 50 %. The radiology billing data were searched for CT-guided musculoskeletal procedures performed over a period of 8 months following the initial implementation of the protocol. These were reviewed for the type of procedure and compliance with the implemented protocol. The compliant CT-guided biopsy cases were then retrospectively reviewed for patient demographics, tumor pathology, and lesion size. Pathology results were compared to the ultimate diagnoses and were categorized as diagnostic, accurate, or successful. Of 92 CT-guided procedures performed during this period, two were excluded as they were not biopsies (one joint injection and one drainage), 19 were excluded due to non-compliance (operators neglected to follow the protocol), and four were excluded due to lack of available follow-up in our electronic medical records. A total of 67 compliant biopsies were performed in 63 patients (two had two biopsies, and one had three biopsies). There were 32 males and 31 females with an average age of 50 (range, 15-84 years). Of the 67 biopsies, five were non-diagnostic and inaccurate and thus unsuccessful (7 %); five were diagnostic but inaccurate and thus unsuccessful (7 %); 57 were diagnostic and accurate thus successful (85 %). These results were comparable with results published in the radiology literature. The success rate of CT-guided biopsies using a low-dose protocol is comparable to published rates for conventional dose biopsies. The implemented low-dose protocol

  18. Effect of pulse repetition rate and number of pulses in the analysis of polypropylene and high density polyethylene by nanosecond infrared laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Leme, Flavio O. [Laboratorio de Quimica Analitica ' Henrique Bergamin Filho' , Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, Av. Centenario 303, 13416-000 Piracicaba, SP (Brazil); Godoi, Quienly [Laboratorio de Quimica Analitica ' Henrique Bergamin Filho' , Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, Av. Centenario 303, 13416-000 Piracicaba, SP (Brazil); Departamento de Quimica, Universidade Federal de Sao Carlos, Rod. Washington Luis, km 235, 13565-905 Sao Carlos, SP (Brazil); Kiyataka, Paulo H.M. [Centro de Tecnologia de Embalagens, Instituto de Tecnologia de Alimentos, Av. Brasil 2880, 13070-178 Campinas, SP (Brazil); Santos, Dario [Departamento de Ciencias Exatas e da Terra, Universidade Federal de Sao Paulo, Rua Prof. Artur Riedel 275, 09972-270 Diadema, SP (Brazil); Agnelli, Jose A.M. [Departamento de Engenharia de Materiais, Universidade Federal de Sao Carlos, Rod. Washington Luis, km 235, 13565-905 Sao Carlos, SP (Brazil); and others

    2012-02-01

    Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO{sub 4}. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm{sup -2}), 2 {mu}s delay time and 6 {mu}s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant.

  19. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  20. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy

    Science.gov (United States)

    Campos, Luciana Tourinho; de Almeida, Carlos Eduardo Veloso

    2015-01-01

    Introduction The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®); it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86), which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21), which is also from BEBIG. Objective and Methods The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the

  1. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, CA (United States); Martinez, Alvaro A.; Ghilezan, Michel [William Beaumont Hospital, Royal Oak, MI (United States); Hill, Dennis R.; Schour, Lionel; Brandt, David [California Endocurietherapy, Oakland, CA (United States); Gustafson, Gary [William Beaumont Hospital, Royal Oak, MI (United States)

    2011-12-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  2. Clinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2016-08-01

    Full Text Available Purpose : In this study, we present the clinical implementation of a novel transoral balloon centering esophageal applicator (BCEA and the initial clinical experience in high-dose-rate (HDR brachytherapy treatment of esophageal cancer, using this applicator. Material and methods: Acceptance testing and commissioning of the BCEA were performed prior to clinical use. Full performance testing was conducted including measurements of the dimensions and the catheter diameter, evaluation of the inflatable balloon consistency, visibility of the radio-opaque markers, congruence of the markers, absolute and relative accuracy of the HDR source in the applicator using the radiochromic film and source position simulator, visibility and digitization of the applicator on the computed tomography (CT images under the clinical conditions, and reproducibility of the offset. Clinical placement of the applicator, treatment planning, treatment delivery, and patient’s response to the treatment were elaborated as well. Results : The experiments showed sub-millimeter accuracy in the source positioning with distal position at 1270 mm. The digitization (catheter reconstruction was uncomplicated due to the good visibility of markers. The treatment planning resulted in a favorable dose distribution. This finding was pronounced for the treatment of the curvy anatomy of the lesion due to the improved repeatability and consistency of the delivered fractional dose to the patient, since the radioactive source was placed centrally within the lumen with respect to the clinical target due to the five inflatable balloons. Conclusions : The consistency of the BCEA positioning resulted in the possibility to deliver optimized non-uniform dose along the catheter, which resulted in an increase of the dose to the cancerous tissue and lower doses to healthy tissue. A larger number of patients and long-term follow-up will be required to investigate if the delivered optimized treatment can

  3. Operational specification and forecasting advances for Dst, LEO thermospheric densities, and aviation radiation dose and dose rate

    Science.gov (United States)

    Tobiska, W. Kent

    Space weather’s effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun’s photons, particles, and fields. Of the space environment domains that are affected by space weather, the magnetosphere, thermosphere, and even troposphere are key regions that are affected. Space Environment Technologies (SET) has developed and is producing innovative space weather applications. Key operational systems for providing timely information about the effects of space weather on these domains are SET’s Magnetosphere Alert and Prediction System (MAPS), LEO Alert and Prediction System (LAPS), and Automated Radiation Measurements for Aviation Safety (ARMAS) system. MAPS provides a forecast Dst index out to 6 days through the data-driven, redundant data stream Anemomilos algorithm. Anemomilos uses observational proxies for the magnitude, location, and velocity of solar ejecta events. This forecast index is used by satellite operations to characterize upcoming geomagnetic storms, for example. In addition, an ENLIL/Rice Dst prediction out to several days has also been developed and will be described. LAPS is the SET fully redundant operational system providing recent history, current epoch, and forecast solar and geomagnetic indices for use in operational versions of the JB2008 thermospheric density model. The thermospheric densities produced by that system, driven by the LAPS data, are forecast to 72-hours to provide the global mass densities for satellite operators. ARMAS is a project that has successfully demonstrated the operation of a micro dosimeter on aircraft to capture the real-time radiation environment due to Galactic Cosmic Rays and Solar Energetic Particles. The dose and dose-rates are captured on aircraft, downlinked in real-time via the Iridium satellites, processed on the ground, incorporated into the most recent NAIRAS global radiation climatology data runs, and made available to end users via the web and

  4. Impact of small MU/segment and dose rate on delivery accuracy of volumetric-modulated arc therapy (VMAT).

    Science.gov (United States)

    Huang, Long; Zhuang, Tingliang; Mastroianni, Anthony; Djemil, Toufik; Cui, Taoran; Xia, Ping

    2016-05-08

    Volumetric-modulated arc therapy (VMAT) plans may require more control points (or segments) than some of fixed-beam IMRT plans that are created with a limited number of segments. Increasing number of control points in a VMAT plan for a given prescription dose could create a large portion of the total number of segments with small number monitor units (MUs) per segment. The purpose of this study is to investigate the impact of the small number MU/segment on the delivery accuracy of VMAT delivered with various dose rates. Ten patient datasets were planned for hippocampus sparing for whole brain irradiation. For each dataset, two VMAT plans were created with maximum dose rates of 600 MU/min (the maximum field size of 21 × 40 cm2) and 1000 MU/min (the maximum field size of 15 × 15 cm2) for a daily dose of 3 Gy. Without reoptimization, the daily dose of these plans was purposely reduced to 1.5 Gy and 1.0 Gy while keeping the same total dose. Using the two dose rates and three different daily doses, six VMAT plans for each dataset were delivered to a physical phantom to investigate how the changes of dose rate and daily doses impact on delivery accuracy. Using the gamma index, we directly compared the delivered planar dose profiles with the reduced daily doses (1.5 Gy and 1.0 Gy) to the delivered planar dose at 3 Gy daily dose, delivered at dose rate of 600 MU/min and 1000 MU/min, respectively. The average numbers of segments with MU/segment ≤ 1 were 35 ± 8, 87 ± 6 for VMAT-600 1.5 Gy, VMAT-600 1 Gy plans, and 30 ± 7 and 42 ± 6 for VMAT-1000 1.5 Gy and VMAT-1000 1 Gy plans, respectively. When delivered at 600 MU/min dose rate, the average gamma index passing rates (1%/1 mm criteria) of comparing delivered 1.5 Gy VMAT planar dose profiles to 3.0 Gy VMAT delivered planar dose profiles was 98.28% ± 1.66%, and the average gamma index passing rate of comparing delivered 1.0 Gy VMAT planar dose to 3.0 Gy VMAT delivered planar dose was 83.75% ± 4.86%. If using 2%/2mm

  5. Radiation Leukemogenesis: Applying Basic Science of Epidemiological Estimates of Low Dose Risks and Dose-Rate Effects

    Energy Technology Data Exchange (ETDEWEB)

    Hoel, D. G.

    1998-11-01

    The next stage of work has been to examine more closely the A-bomb leukemia data which provides the underpinnings of the risk estimation of CML in the above mentioned manuscript. The paper by Hoel and Li (Health Physics 75:241-50) shows how the linear-quadratic model has basic non-linearities at the low dose region for the leukemias including CML. Pierce et. al., (Radiation Research 123:275-84) have developed distributions for the uncertainty in the estimated exposures of the A-bomb cohort. Kellerer, et. al., (Radiation and Environmental Biophysics 36:73-83) has further considered possible errors in the estimated neutron values and with changing RBE values with dose and has hypothesized that the tumor response due to gamma may not be linear. We have incorporated his neutron model and have constricted new A-bomb doses based on his model adjustments. The Hoel and Li dose response analysis has also been applied using the Kellerer neutron dose adjustments for the leukemias. Finally, both Pierce's dose uncertainties and Kellerer neutron adjustments are combined as well as the varying RBE with dose as suggested by Rossi and Zaider and used for leukemia dose-response analysis. First the results of Hoel and Li showing a significantly improved fit of the linear-quadratic dose response by the inclusion of a threshold (i.e. low-dose nonlinearity) persisted. This work has been complete for both solid tumor as well as leukemia for both mortality as well as incidence data. The results are given in the manuscript described below which has been submitted to Health Physics.

  6. Feasibility of pulse wave velocity estimation from low frame rate US sequences in vivo

    Science.gov (United States)

    Zontak, Maria; Bruce, Matthew; Hippke, Michelle; Schwartz, Alan; O'Donnell, Matthew

    2017-03-01

    The pulse wave velocity (PWV) is considered one of the most important clinical parameters to evaluate CV risk, vascular adaptation, etc. There has been substantial work attempting to measure the PWV in peripheral vessels using ultrasound (US). This paper presents a fully automatic algorithm for PWV estimation from the human carotid using US sequences acquired with a Logic E9 scanner (modified for RF data capture) and a 9L probe. Our algorithm samples the pressure wave in time by tracking wall displacements over the sequence, and estimates the PWV by calculating the temporal shift between two sampled waves at two distinct locations. Several recent studies have utilized similar ideas along with speckle tracking tools and high frame rate (above 1 KHz) sequences to estimate the PWV. To explore PWV estimation in a more typical clinical setting, we used focused-beam scanning, which yields relatively low frame rates and small fields of view (e.g., 200 Hz for 16.7 mm filed of view). For our application, a 200 Hz frame rate is low. In particular, the sub-frame temporal accuracy required for PWV estimation between locations 16.7 mm apart, ranges from 0.82 of a frame for 4m/s, to 0.33 for 10m/s. When the distance is further reduced (to 0.28 mm between two beams), the sub-frame precision is in parts per thousand (ppt) of the frame (5 ppt for 10m/s). As such, the contributions of our algorithm and this paper are: 1. Ability to work with low frame-rate ( 200Hz) and decreased lateral field of view. 2. Fully automatic segmentation of the wall intima (using raw RF images). 3. Collaborative Speckle Tracking of 2D axial and lateral carotid wall motion. 4. Outlier robust PWV calculation from multiple votes using RANSAC. 5. Algorithm evaluation on volunteers of different ages and health conditions.

  7. A kinetic model for estimating net photosynthetic rates of cos lettuce leaves under pulsed light.

    Science.gov (United States)

    Jishi, Tomohiro; Matsuda, Ryo; Fujiwara, Kazuhiro

    2015-04-01

    Time-averaged net photosynthetic rate (P n) under pulsed light (PL) is known to be affected by the PL frequency and duty ratio, even though the time-averaged photosynthetic photon flux density (PPFD) is unchanged. This phenomenon can be explained by considering that photosynthetic intermediates (PIs) are pooled during light periods and then consumed by partial photosynthetic reactions during dark periods. In this study, we developed a kinetic model to estimate P n of cos lettuce (Lactuca sativa L. var. longifolia) leaves under PL based on the dynamics of the amount of pooled PIs. The model inputs are average PPFD, duty ratio, and frequency; the output is P n. The rates of both PI accumulation and consumption at a given moment are assumed to be dependent on the amount of pooled PIs at that point. Required model parameters and three explanatory variables (average PPFD, frequency, and duty ratio) were determined for the simulation using P n values under PL based on several combinations of the three variables. The model simulation for various PL levels with a wide range of time-averaged PPFDs, frequencies, and duty ratios further demonstrated that P n under PL with high frequencies and duty ratios was comparable to, but did not exceed, P n under continuous light, and also showed that P n under PL decreased as either frequency or duty ratio was decreased. The developed model can be used to estimate P n under various light environments where PPFD changes cyclically.

  8. Determination of the absorbed dose rate to water for the 18-mm helmet of a gamma knife.

    Science.gov (United States)

    Chung, Hyun-Tai; Park, Youngho; Hyun, Sangil; Choi, Yongsoo; Kim, Gi Hong; Kim, Dong Gyu; Chun, Kook Jin

    2011-04-01

    To measure the absorbed dose rate to water of (60)Co gamma rays of a Gamma Knife Model C using water-filled phantoms (WFP). Spherical WFP with an equivalent water depth of 5, 7, 8, and 9 cm were constructed. The dose rates at the center of an 18-mm helmet were measured in an 8-cm WFP (WFP-3) and two plastic phantoms. Two independent measurement systems were used: one was calibrated to an air kerma (Set I) and the other was calibrated to the absorbed dose to water (Set II). The dose rates of WFP-3 and the plastic phantoms were converted to dose rates for an 8-cm water depth using the attenuation coefficient and the equivalent water depths. The dose rate measured at the center of WFP-3 using Set II was 2.2% and 1.0% higher than dose rates measured at the center of the two plastic phantoms. The measured effective attenuation coefficient of Gamma Knife photon beam in WFPs was 0.0621 cm(-1). After attenuation correction, the difference between the dose rate at an 8-cm water depth measured in WFP-3 and dose rates in the plastic phantoms was smaller than the uncertainty of the measurements. Systematic errors related to the characteristics of the phantom materials in the dose rate measurement of a Gamma Knife need to be corrected for. Correction of the dose rate using an equivalent water depth and attenuation provided results that were more consistent. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. A megawatt solid-state modulator for high repetition rate pulse generation

    Science.gov (United States)

    Wang, Y.; Pribyl, P.; Gekelman, W.

    2016-02-01

    A novel solid-state modulator capable of generating rapid consecutive power pulses is constructed to facilitate experiments on plasma interaction with high power microwave pulses. The modulator is designed to output a 100 kHz tone burst, which consists of up to 10 pulses, each with 1 μs duration and 1 MW peak power. The pulses are formed by discharging a total of 480 μF capacitors through 24 synchronized MOSFETs and 6 step-up transformers. The highly modular design, as a replacement of an old single-pulse version used in earlier experiments which employs a pulse forming network, brings great flexibility and wide potential to its application. A systematic cost-effectiveness analysis is also presented.

  10. A Real-Time Terahertz Time-Domain Polarization Analyzer with 80-MHz Repetition-Rate Femtosecond Laser Pulses

    Directory of Open Access Journals (Sweden)

    Takehiro Tachizaki

    2013-03-01

    Full Text Available We have developed a real-time terahertz time-domain polarization analyzer by using 80-MHz repetition-rate femtosecond laser pulses. Our technique is based on the spinning electro-optic sensor method, which we recently proposed and demonstrated by using a regenerative amplifier laser system; here we improve the detection scheme in order to be able to use it with a femtosecond laser oscillator with laser pulses of a much higher repetition rate. This improvement brings great advantages for realizing broadband, compact and stable real-time terahertz time-domain polarization measurement systems for scientific and industrial applications.

  11. A real-time terahertz time-domain polarization analyzer with 80-MHz repetition-rate femtosecond laser pulses.

    Science.gov (United States)

    Watanabe, Shinichi; Yasumatsu, Naoya; Oguchi, Kenichi; Takeda, Masatoshi; Suzuki, Takeshi; Tachizaki, Takehiro

    2013-03-11

    We have developed a real-time terahertz time-domain polarization analyzer by using 80-MHz repetition-rate femtosecond laser pulses. Our technique is based on the spinning electro-optic sensor method, which we recently proposed and demonstrated by using a regenerative amplifier laser system; here we improve the detection scheme in order to be able to use it with a femtosecond laser oscillator with laser pulses of a much higher repetition rate. This improvement brings great advantages for realizing broadband, compact and stable real-time terahertz time-domain polarization measurement systems for scientific and industrial applications.

  12. 3.7 GHz repetition rate operated narrow-bandwidth picosecond pulsed Yb fiber amplifier with an all-fiber multiplier

    Science.gov (United States)

    Wei, K. H.; Wen, R. H.; Guo, Y.

    2016-04-01

    A high power picosecond pulsed Yb fiber amplifier with a pulse repetition rate of 3.7 GHz is experimentally demonstrated. The seed is a gain switched distributed Bragg reflection (DBR) structured laser diode (LD) with a pulse duration of 130 ps and a repetition rate of 460 MHz. The pulse repetition rate is increased to 3.7 GHz by introducing an all-fiber multiplier, which is composed of four 2  ×  2 structured fiber couplers. The multiplied pulse train is amplified to 81 W through two stage Yb fiber amplifiers.

  13. High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Petera, J.; Odrazka, K.; Zouhar, M.; Bedrosova, J.; Dolezel, M. [Dept. of Oncology and Radiotherapy, Charles Univ. Medical School and Teaching Hospital, Hradec Kralove (Czech Republic)

    2004-02-01

    Background: interstitial low-dose-rate (LDR) brachytherapy allows conservative treatment of T1-T2 penile carcinoma. High-dose-rate (HDR) is often considered to be dangerous for interstitial implants because of a higher risk of complications, but numerous reports suggest that results may be comparable to LDR. Nevertheless, there are no data in the literature available regarding HDR interstitial brachytherapy for carcinoma of the penis. Case report: a 64-year-old man with T1 NO MO epidermoid carcinoma of the glans is reported. Interstitial HDR brachytherapy was performed using the stainless hollow needle technique and a breast template for fixation and good geometry. The dose delivered was 18 x 3 Gy twice daily. Results: after 232 days from brachytherapy, the patient was without any evidence of the tumor, experienced no serious radiation-induced complications, and had a fully functional organ. Conclusion: HDR interstitial brachytherapy is feasible in selected case of penis carcinoma, when careful planning and small single fractions are used. (orig.)

  14. Dose-rate dependent effects of ionizing radiation on vascular reactivity.

    Science.gov (United States)

    Suvorava, T; Luksha, L; Bulanova, K Ya; Lobanok, L M

    2006-01-01

    This study was designed to investigate the dose-rate dependent effects of ionising radiation on endothelium- and NO-mediated reactivity of aorta and coronary vessels. Rats were exposed to acute ((137)Cs, 9 x 10(-4) Gy s(-1), 18 min) and chronic ((137)Cs, 2.8 x 10(-7) Gy s(-1), 41 days) radiation in 1 Gy dose. Acute irradiation transiently increased coronary flow in eNOS-activity-dependent manner on day 3 after exposure. In striking contrast, chronic irradiation caused a significant depression of coronary flow even on day 90 after irradiation and abolished the effects of NO-synthase inhibitor N-nitro-L-arginine methyl ester (10 micromol l(-1)). Furthermore, low intensity radiation strongly diminished the vasodilator properties of NO-donor sodium nitroprusside (5 micromol l(-1)). A similar pattern was observed in aortic rings. Endothelium-dependent vasodilation was increased on days 3 and 10 after acute irradiation, but strongly inhibited following chronic exposure for the entire post-radiation period. This was accompanied by a diminished vasodilator response to NO-donor on days 3, 10 and 30 of post-radiation but not on day 90. The data suggest that ionising radiation in 1 Gy induces changes of aortic and coronary vessels reactivity depending on the dose-rate and the interval after exposure.

  15. Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography

    Science.gov (United States)

    Bergese, Sergio D.; Kelley, Scott D.; McIntyre, Robert; Uribe, Alberto A.; Sethi, Rakesh; Watson, James N.; Addison, Paul S.

    2017-01-01

    BACKGROUND: Intermittent measurement of respiratory rate via observation is routine in many patient care settings. This approach has several inherent limitations that diminish the clinical utility of these measurements because it is intermittent, susceptible to human error, and requires clinical resources. As an alternative, a software application that derives continuous respiratory rate measurement from a standard pulse oximeter has been developed. We sought to determine the performance characteristics of this new technology by comparison with clinician-reviewed capnography waveforms in both healthy subjects and hospitalized patients in a low-acuity care setting. METHODS: Two independent observational studies were conducted to validate the performance of the Medtronic NellcorTM Respiration Rate Software application. One study enrolled 26 healthy volunteer subjects in a clinical laboratory, and a second multicenter study enrolled 53 hospitalized patients. During a 30-minute study period taking place while participants were breathing spontaneously, pulse oximeter and nasal/oral capnography waveforms were collected. Pulse oximeter waveforms were processed to determine respiratory rate via the Medtronic Nellcor Respiration Rate Software. Capnography waveforms reviewed by a clinician were used to determine the reference respiratory rate. RESULTS: A total of 23,243 paired observations between the pulse oximeter-derived respiratory rate and the capnography reference method were collected and examined. The mean reference-based respiratory rate was 15.3 ± 4.3 breaths per minute with a range of 4 to 34 breaths per minute. The Pearson correlation coefficient between the Medtronic Nellcor Respiration Rate Software values and the capnography reference respiratory rate is reported as a linear correlation, R, as 0.92 ± 0.02 (P Medtronic Nellcor Respiration Rate Software was 0.18 breaths per minute with a precision (SD) of 1.65 breaths per minute (healthy volunteers: 0.37 ± 0

  16. Background radiation dose-rates to non-human biota in a high mountain habitat in Norway

    DEFF Research Database (Denmark)

    Brown, J.E.; Gelsvik, R.; Kålås, J.A.

    2009-01-01

    Determination of background radiation dose-rates is important in the process of assessing risks to the environment from exposure to human activities both in terms of deriving the incremental dose-rate and as a point of reference for evaluating the significance of the exposure level. A consideration...

  17. Synergistic effect of nanosecond pulsed electric field combined with low-dose of pingyangmycin on salivary adenoid cystic carcinoma.

    Science.gov (United States)

    Qi, Wei; Guo, Jinsong; Wu, Shan; Su, Bo; Zhang, Lei; Pan, Jie; Zhang, Jue

    2014-05-01

    Adenoid cystic carcinoma (ACC) is one of the most common malignant neoplasms in salivary glands. To evaluate the therapeutic effects of nanosecond pulsed electric field (nsPEF) combined with pingyangmycin (PYM) on salivary gland adenoid cystic carcinoma (SACC), ACC high metastatic cell line (SACC-LM) and low metastatic cell line (SACC‑83) were tested by CCK-8 assay, cell clonogenic assay, flow cytometry and Transwell assay. Extracellular matrix metalloproteinase inducer (EMMPRIN) expression was tested by western blotting to verify the synergistic mechanism of nsPEF and PYM. The results showed that nsPEF inhibited the cell proliferation of both cell lines, and the inhibitory effect was strongly associated with time and electrical field strength. Moreover, PYM combined with nsPEF may enhance the suppression effect significantly, even at a very low dose (0.01 µg/ml). The synergistic effects may contribute to the downregulation of EMMPRIN expression resulting from the application of nsPEF. For SACC, nsPEF combined with chemotherapy agents may be a valuable strategy not only to improve the treatment effect and prognosis, but also to reduce the side-effects of chemotherapy.

  18. A method applicable to effective dose rate estimates for aircrew dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, A.; Pelliccioni, M.; Rancati, T

    2001-07-01

    The inclusion of cosmic radiation as occupational exposure under ICRP Publication 60 and the European Union Council Directive 96/29/Euratom has highlighted the need to estimate the exposure of aircrew. According to a report of the Group of Experts established under the terms of Article 31 of the European Treaty, the individual estimates of dose for flights below 15 km may be done using an appropriate computer program. In order to calculate the radiation exposure at aircraft altitudes, calculations have been performed by means of the Monte Carlo transport code FLUKA. On the basis of the calculated results, a simple method is proposed for the individual evaluation of effective dose rate due to the galactic component of cosmic radiation as a function of latitude and altitude. (author)

  19. A method applicable to effective dose rate estimates for aircrew dosimetry

    CERN Document Server

    Ferrari, A; Rancati, T

    2001-01-01

    The inclusion of cosmic radiation as occupational exposure under ICRP Publication 60 and the European Union Council Directive 96/29/Euratom has highlighted the need to estimate the exposure of aircrew. According to a report of the Group of Experts established under the terms of Article 31 of the European Treaty, the individual estimates of dose for flights below 15 km may be done using an appropriate computer program. In order to calculate the radiation exposure at aircraft altitudes, calculations have been performed by means of the Monte Carlo transport code FLUKA. On the basis of the calculated results, a simple method is proposed for the individual evaluation of effective dose rate due to the galactic component of cosmic radiation as a function of latitude and altitude. (13 refs).

  20. Dependence of alanine gel dosimeter response as a function of photon clinical beams dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo, E-mail: cleber.feijo@famesp.com.br [Faculdade Metodo de Sao Paulo (FAMESP), SP (Brazil); Campos, Leticia Lucente, E-mail: Icrodri@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-11-01

    Gel dosimetry is a new area developed by Gore, it is ery useful for application in radiotherapy because using NMR imaging as evaluation technique is possible to evaluate three dimensional absorbed dose distribution. The measure technique is based on difference of ferrous (Fe{sup 2+}) and ferric (Fe{sup 3+}) ) ions concentration that can be measured also by spectrophotometry technique. The Alanine gel dosimeter was developed at IPEN. The alanine is an amino acid and tissue equivalent material that presents significant improvement on previous alanine dosimetry systems. The addition of Alanine increases the production of ferric ions in the solution. This work aims to study the dose rate dependence of photon clinical beams radiation on the alanine gel dosimeter optical response, as well as the response repeatability and gel production reproducibility, since this property is very important for characterization and standardization of any dosimeter. (author)

  1. High dose rate interstitial brachytherapy in soft tissue sarcomas: technical aspect

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Mi Son; Kang, Seung Hee; Kim, Byoung Suck; Oh, Young Taek [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1999-03-01

    To discuss the technical aspect of interstitial brachytherapy including method of implant, insertion time of radioactive source, total radiation dose, and complication, we reviewed patients who had diagnoses of soft tissue sarcoma and were treated by conservative surgery, interstitial implant and external beam radiation therapy. Between May 1995 and Dec. 1997, the patients with primary or recurrent soft tissue sarcoma underwent surgical resection (wide margin excision) and received radiotherapy including interstitial brachytherapy. Catheters were placed with regular intervals of 1-1.5 cm immediately after tumor removal and covering the critical structures, such as neurovascular bundle or bone, with gelform, muscle, or tissue expander in the cases where the tumors were close to those structures. Brachytherapy consisted of source axis with 2-2.5 Gy/fraction, twice a day, starting on 6th day after the surgery. Within one month after the surgery, total dose of 50-55 Gy was delivered to the tumor bed with wide margin by the external beam radiotherapy. All patients completed planned interstitial brachytherapy without acute side effects directly related with catheter implantation such as infection or bleeding. With median follow up duration of 25 months (range 12-41 months), no local recurrences were observed. And there was no severe form of chromic complication (RTOG/EORTC grade 3 or 4). The high dose rate interstitial brachytherapy is easy and safe way to minimize the radiation dose delivered to the adjacent normal tissue and to decrease radiation induced chronic morbidity such as fibrosis by reducing the total dose of external radiotherapy in the management of soft tissue sarcoma with conservative surgery.

  2. Evaluation of ambient dose equivalent rates influenced by vertical and horizontal distribution of radioactive cesium in soil in Fukushima Prefecture

    CERN Document Server

    Malins, Alex; Nakama, Shigeo; Saito, Tatsuo; Okumura, Masahiko; Machida, Masahiko; Kitamura, Akihiro

    2016-01-01

    The air dose rate in an environment contaminated with 134Cs and 137Cs depends on the amount, depth profile and horizontal distribution of these contaminants within the ground. This paper introduces and verifies a tool that models these variables and calculates ambient dose equivalent rates at 1 m above the ground. Good correlation is found between predicted dose rates and dose rates measured with survey meters in Fukushima Prefecture in areas contaminated with radiocesium from the Fukushima Dai-ichi Nuclear Power Plant accident. This finding is insensitive to the choice for modelling the activity depth distribution in the ground using activity measurements of collected soil layers, or by using exponential and hyperbolic secant fits to the measurement data. Better predictions are obtained by modelling the horizontal distribution of radioactive cesium across an area if multiple soil samples are available, as opposed to assuming a spatially homogeneous contamination distribution. Reductions seen in air dose rate...

  3. Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

    Science.gov (United States)

    Shetty, Saurabha; Majumder, Dipanjan; Adurkar, Pranjal; Swamidas, Jamema; Engineer, Reena; Chopra, Supriya; Shrivastava, Shyamkishore

    2017-01-01

    Purpose The aim of this study is to compare 3D dose volume histogram (DVH) parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT) in cervical cancer, and to find optimized bladder volume. Material and methods This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1), after 50 ml (series 2), and 100 ml (series 3) bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results The mean (± SD) bladder volume was 64.5 (± 25) cc, 116.2 (± 28) cc, and 172.9 (± 29) cc, for series 1, 2, and 3, respectively. The 0.1 cm3,1 cm3, 2 cm3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm3, 1 cm3, and 2 cm3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1) compared to full bladder (series 3) (p = 0.03) was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume during cervical

  4. Performance assessment of the BEBIG MultiSource high dose rate brachytherapy treatment unit.

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-21

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource High Dose Rate (HDR) brachytherapy treatment unit with an (192)Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  5. Fuji Amulet 1000 MS mammography system and radiation dose rate at the image receptor; El mamografo Fuji Amulet 1000 MS y la tasa de dosis de radiacion en el receptor de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Rivas Bailarin, M. A.; Ruiz Manzano, P.; Jimenez Albericio, J.

    2011-07-01

    Measurements for commissioning and for establishing the performance reference level of Fuji Amulet 1000 MS mammography digital system yielded conflicting results regarding compliance with the defined tolerances for dose rate at the receiver input defined at the Spanish Protocol for Quality Control in Diagnostic X-Ray Systems. It was found that this result is due to the pulsed nature of the radiation emitted and it is concluded by recommending that in these cases dose rate has to be measured at tube loadings typical of clinical examinations (50 mAs or higher). (Author) 2 refs.

  6. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph

    Directory of Open Access Journals (Sweden)

    Kristen M. Warren

    2016-03-01

    Full Text Available Photoplethysmographic (PPG waveforms are used to acquire pulse rate (PR measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA, limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.

  7. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph.

    Science.gov (United States)

    Warren, Kristen M; Harvey, Joshua R; Chon, Ki H; Mendelson, Yitzhak

    2016-03-07

    Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.

  8. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph

    Science.gov (United States)

    Warren, Kristen M.; Harvey, Joshua R.; Chon, Ki H.; Mendelson, Yitzhak

    2016-01-01

    Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data. PMID:26959034

  9. Combined heart rate variability and pulse oximetry biofeedback for chronic obstructive pulmonary disease: preliminary findings.

    Science.gov (United States)

    Giardino, Nicholas D; Chan, Leighton; Borson, Soo

    2004-06-01

    The purpose of this study was to examine the feasibility of an intervention that included heart rate variability (HRV) biofeedback and walking with pulse oximetry feedback to improve functioning and quality of life for patients with chronic obstructive pulmonary disease (COPD). Twenty patients with COPD participated in 5 weekly sessions of HRV biofeedback and 4 weekly sessions of walking practice with oximetry feedback, with instructions for daily home practice. Primary outcomes measures were the distance walked in 6 min (6MWD) and overall quality of life, as measured by the St. George's Respiratory Questionnaire (SGRQ). Secondary outcomes included measures of self-efficacy, self-reported disability, anxiety, depression, dyspnea before and after the 6MWD, and HRV at the frequency of respiration during spontaneous and paced breathing. After 10 weeks of training, participants showed statistically and clinically significant improvements in 6MWD and quality of life. Significant changes were also seen in self-efficacy, disability, dyspnea before and after the 6MWD, and HRV amplitude during spontaneous breathing. We conclude that our intervention is feasible for patients with COPD and that further research using a randomized controlled design is warranted.

  10. Influence of the excitation light intensity on the rate of fluorescence quenching reactions: pulsed experiments.

    Science.gov (United States)

    Angulo, Gonzalo; Milkiewicz, Jadwiga; Kattnig, Daniel; Nejbauer, Michał; Stepanenko, Yuriy; Szczepanek, Jan; Radzewicz, Czesław; Wnuk, Paweł; Grampp, Günter

    2017-02-22

    The effect of multiple light excitation events on bimolecular photo-induced electron transfer reactions in liquid solution is studied experimentally. It is found that the decay of fluorescence can be up to 25% faster if a second photon is absorbed after a first cycle of quenching and recombination. A theoretical model is presented which ascribes this effect to the enrichment of the concentration of quenchers in the immediate vicinity of fluorophores that have been previously excited. Despite its simplicity, the model delivers a qualitative agreement with the observed experimental trends. The original theory by Burshtein and Igoshin (J. Chem. Phys., 2000, 112, 10930-10940) was created for continuous light excitation though. A qualitative extrapolation from the here presented pulse experiments to the continuous excitation conditions lead us to conclude that in the latter the order of magnitude of the increase of the quenching efficiency upon increasing the light intensity of excitation, must also be on the order of tens of percent. These results mean that the rate constant for photo-induced bimolecular reactions depends not only on the usual known factors, such as temperature, viscosity and other properties of the medium, but also on the intensity of the excitation light.

  11. Diagnosis of PLMD from increased pulse rate variability on overnight oximetry.

    Science.gov (United States)

    Krishnaswamy, Uma M; Higgins, Sean E; Kosky, Christopher A; Delacy, Simone; Williams, Adrian J

    2010-01-01

    This study was undertaken in a group of patients with periodic limb movement disorder (PLMD) to assess whether the presence of increased pulse rate variability (PRV) without desaturation on overnight oximetry was suggestive of the occurrence of periodic limb movements (PLMs). Seventy sleepy patients with a polysomnographic diagnosis of PLMD and 25 controls with obstructive sleep apnea were included in this retrospective study. All patients had undergone initial domiciliary oximetry and subsequent polysomnography (PSG). The oximetry tracings were independently interpreted by five sleep unit personnel for the presence of increased PRV. Further, the association between increased PRV and PLMs was evaluated in the summary graph of the PSG. Fifty seven (81.4%) patients had definite evidence of increased PRV without episodes of desaturation on initial oximetry, which was later confirmed to be due to PLMs on PSG. 13 (18.6%) patients had no PRV on oximetry and PSG but had PLMD. The inter-interpreter concurrence in suspecting a diagnosis of PLMD based on oximetry alone was more than 80% in 64 (91%) patients. The presence of isolated increased PRV on overnight oximetry is a valuable tool in suspecting nonsleep apnea disorders like PLMD.

  12. Frequency Domain Analysis for Assessing Fluid Responsiveness by Using Instantaneous Pulse Rate Variability

    Directory of Open Access Journals (Sweden)

    Pei-Chen Lin

    2016-02-01

    Full Text Available In the ICU, fluid therapy is conventional strategy for the patient in shock. However, only half of ICU patients have well-responses to fluid therapy, and fluid loading in non-responsive patient delays definitive therapy. Prediction of fluid responsiveness (FR has become intense topic in clinic. Most of conventional FR prediction method based on time domain analysis, and it is limited ability to indicate FR. This study proposed a method which predicts FR based on frequency domain analysis, named instantaneous pulse rate variability (iPRV. iPRV provides a new indication in very high frequency (VHF range (0.4-0.8Hz of spectrum for peripheral responses. Twenty six healthy subjects participated this study and photoplethysmography signal was recorded in supine baseline, during head-up tilt (HUT, and passive leg raising (PLR, which induces variation of venous return and helps for quantitative assessment of FR individually. The result showed the spectral power of VHF decreased during HUT (573.96±756.36 ms2 in baseline; 348.00±434.92 ms2 in HUT and increased during PLR (573.96±756.36 ms2 in baseline; 718.92±973.70 ms2 in PLR, which present the compensated regulation of venous return and FR. This study provides an effective indicator for assessing FR in frequency domain and has potential to be a reliable system in ICU.

  13. Dose-rate effects of ethylene oxide exposure on developmental toxicity.

    Science.gov (United States)

    Weller, E; Long, N; Smith, A; Williams, P; Ravi, S; Gill, J; Henessey, R; Skornik, W; Brain, J; Kimmel, C; Kimmel, G; Holmes, L; Ryan, L

    1999-08-01

    In risk assessment, evaluating a health effect at a duration of exposure that is untested involves assuming that equivalent multiples of concentration (C) and duration (T) of exposure have the same effect. The limitations of this approach (attributed to F. Haber, Zur Geschichte des Gaskrieges [On the history of gas warfare], in Funf Vortrage aus den Jahren 1920-1923 [Five lectures from the years 1920-1923], 1924, Springer, Berlin, pp. 76-92), have been noted in several studies. The study presented in this paper was designed to specifically look at dose-rate (C x T) effects, and it forms an ideal case study to implement statistical models and to examine the statistical issues in risk assessment. Pregnant female C57BL/6J mice were exposed, on gestational day 7, to ethylene oxide (EtO) via inhalation for 1.5, 3, or 6 h at exposures that result in C x T multiples of 2100 or 2700 ppm-h. EtO was selected because of its short half-life, documented developmental toxicity, and relevance to exposures that occur in occupational settings. Concurrent experiments were run with animals exposed to air for similar periods. Statistical analysis using models developed to assess dose-rate effects revealed significant effects with respect to fetal death and resorptions, malformations, crown-to-rump length, and fetal weight. Animals exposed to short, high exposures of EtO on day 7 of gestation were found to have more adverse effects than animals exposed to the same C x T multiple but at longer, lower exposures. The implication for risk assessment is that applying Haber's Law could potentially lead to an underestimation of risk at a shorter duration of exposure and an overestimation of risk at a longer duration of exposure. Further research, toxicological and statistical, are required to understand the mechanism of the dose-rate effects, and how to incorporate the mechanistic information into the risk assessment decision process.

  14. Radioactivity measurements and dose rate calculations using ERICA tool in the terrestrial environment of Greece.

    Science.gov (United States)

    Sotiropoulou, Maria; Florou, Heleny; Manolopoulou, Metaxia

    2016-06-01

    In the present study, the radioactivity levels to which terrestrial non-human biota were exposed are examined. Organisms (grass and herbivore mammals) and abiotic components (soil) were collected during the period of 2010 to 2014 from grasslands where sheep and goats were free-range grazing. Natural background radionuclides ((226)Ra, (228)Ra, (228)Th) and artificial radionuclides ((137)Cs, (134)Cs, (131)I) were detected in the collected samples using gamma spectrometry. The actual measured activity concentrations and site-specific data of the studied organisms were imported in ERICA Assessment Tool (version 1.2.0) in order to provide an insight of the radiological dose rates. The highest activity concentrations were detected in samples collected from Lesvos island and the lowest in samples collected from Attiki and Etoloakarnania prefectures. The highest contribution to the total dose rate was clearly derived from the internal exposure and is closely related to the exposure to alpha emitters of natural background ((226)Ra and (228)Th). The Fukushima-derived traces of (137)Cs, (134)Cs, and (131)I, along with the residual (137)Cs, resulted in quite low contribution to the total dose rate. The obtained results may strengthen the adaptation of software tools to a wider range of ecosystems and may be proved useful in further research regarding the possible impact of protracted low level ionizing radiation on non-human biota. This kind of studies may contribute to the effective incorporation of dosimetry tools in the development of integrated environmental and radiological impact assessment policies.

  15. Dose-rate and total-dose radiation testing of the Texas Instruments TMS320C30 32-bit floating point digital signal processor. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Siy, P.F.; Carter, J.T.; D' Addario, L.R.; Loeber, D.A.

    1991-08-01

    The MITRE Corporation has performed in-flux radiation testing of the Texas Instruments TMS320C30 32-bit floating point digital signal processor in both total dose and dose rate radiation environments. This test effort has provided data relating to the applicability of the TMS320C30 in systems with total dose and/or dose rate survivability requirements. In order to accomplish these tests, the MITRE Corporation developed custom hardware and software for in-flux radiation testing. This paper summarizes the effort by providing an overview of the TMS320C30, MITRE's test methodology, test facilities, statistical analysis, and full coverage of the test results. (Author)