  1. Development of subpicosecond pulse radiolysis system

    CERN Document Server

    Kozawa, T; Miki, M; Yamamoto, T; Suemine, S; Yoshida, Y; Tagawa, S

    2000-01-01

    The highest time resolution of the pulse radiolysis had remained about 30 ps since the late 1960s. To make clear the primary processes in the radiation chemistry and physics within 30 ps, we developed a stroboscopic pulse radiolysis system for the absorption spectroscopy with the time resolution of 2.0 ps (10-90% rise time). The time resolution of 2.0 ps was estimated from the time-dependent behavior of the hydrated electrons. The system consists of a subpicosecond electron linac as an irradiation source, a femtosecond laser as an analyzing light and a jitter compensation system.

  2. Ion beam pulse radiolysis system at HIMAC

    Energy Technology Data Exchange (ETDEWEB)

    Chitose, N.; Katsumura, Y.; Domae, M.; Ishigure, K. [Tokyo Univ. (Japan); Murakami, T.

    1997-03-01

    An ion beam pulse radiolysis system has been constructed at HIMAC facility. Ion beam of 24MeV He{sup 2+} with the duration longer than 1 {mu}s is available for irradiation. Three kinds of aqueous solutions, (C{sub 6}H{sub 5}){sub 2}CO, NaHCO{sub 3}, and KSCN, were irradiated and the absorption signals corresponding to (C{sub 6}H{sub 5}){sub 2}CO{sup -}, CO{sub 3}{sup -}, and (SCN){sub 2}{sup -} respectively were observed. Ghost signals which interfere with the measurement are also discussed. (author)

  3. Pulse Radiolysis of Aqueous Thiocyanate Solution

    Energy Technology Data Exchange (ETDEWEB)

    Milosavljevic, Bratoljub H.; LaVerne, Jay A.

    2005-01-13

    The pulse radiolysis of N2O saturated aqueous solutions of KSCN was studied under neutral pH conditions. The observed optical absorption spectrum of the SCN• radical in solution is more complex than previously reported, but it is in good agreement with that measured in the gas phase. Kinetic traces at 330 nm and 472 nm corresponding to SCN• and (SCN)2•¯, respectively, were fit using a Monte Carlo simulation kinetic model. The rate coefficient for the oxidation of SCN¯ ions by OH radicals, an important reaction used in competition kinetics measurements, was found to be 1.4 ± 0.1 x 1010 M-1 s-1, about 30 % higher than the normally accepted value. A detailed discussion of the reaction mechanism is presented.

  4. Pulse radiolysis study on several fluoroquinolones

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Peng [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Graduate University of Chinese Academy of Science, Beijing 100049 (China); Yao Side [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li Haixia; Song Xiyu; Liu Yancheng [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Graduate University of Chinese Academy of Science, Beijing 100049 (China); Wang Wenfeng, E-mail: wangwenfeng@sinap.ac.c [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2011-04-15

    Reactions of several fluoroquinolones (FQs), including enoxacin, norfloxacin, and ciprofloxacin, with various reactive species such as e{sub aq}{sup -}, N{sup {center_dot}}{sub 3}, and {sup {center_dot}O}H are investigated by pulse radiolysis techniques. The FQ radical anions formed in the reactions of FQs with e{sub aq}{sup -} could either be protonated or deprotonated, and the absorption of FQ radical anions was located around 370 nm. The absorption of the neutral radicals produced in the protonation, and the radical dianions produced in the deprotonation of FQ radical anions were located in the 500-750 nm region. The FQ radical cations formed in the reactions of FQs with N{sub 3}{sup {center_dot}} showed an absorption band around 360 nm. Due to the strong bleaching below 350 nm, the absorption maxima ({lambda}{sub max}) of FQ radical anions, and the {lambda}{sub max} of FQ radical cations were not confirmed. The absorption of the FQ radical anions and cations was clearly pH dependent. Under neutral conditions, the reaction rate constants of FQs with e{sub aq}{sup -} and {sup {center_dot}O}H, which are diffusion controlled, were determined.

  5. Pulse radiolysis of pyridine and methylpyridines in aqueous solutions

    DEFF Research Database (Denmark)

    Solar, S.; Getoff, N.; Sehested, K.

    1993-01-01

    The radicals formed from pyridine, 3-methylpyridine, 3,5-dimethylpyridine, 2,6-dimethylpyridine and 2,4,6-trimethylpyridine by attack of H, e(aq)-, OH and O.- in aqueous solutions were investigated by pulse radiolysis in the pH-range 1-13.8. The UV-vis. absorption spectra as well as the formation...

  6. Pulse Radiolysis at High Temperatures and High Pressures

    DEFF Research Database (Denmark)

    Christensen, H.; Sehested, Knud

    1981-01-01

    A set-up enabling pulse radiolysis measurements at high temperatures (up to 320°C) and high pressures (up to 140 bar) has been constructed in collaboration between Risö National Laboratory and Studsvik Energiteknik. The cell has been used for experiments with aqueous solutions with the purpose...

  7. Development of a new picosecond pulse radiolysis system by using a femtosecond laser synchronized with a picosecond linac. A step to femtosecond pulse radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Yoichi; Yamamoto, Tamotsu; Miki, Miyako; Seki, Shu; Okuda, Shuichi; Honda, Yoshihide; Kimura, Norio; Tagawa, Seiichi [Osaka Univ., Ibaraki (Japan). Inst. of Scientific and Industrial Research; Ushida, Kiminori

    1997-03-01

    A new picosecond pulse radiolysis system by using a Ti sapphire femtosecond laser synchronized with a 20 ps electron pulse from the 38 MeV L-band linac has been developed for the research of the ultra fast reactions in primary processes of radiation chemistry. The timing jitter in the synchronization of the laser pulse with the electron pulse is less than several picosecond. The technique can be used in the next femtosecond pulse radiolysis. (author)

  8. A pulse radiolysis study on electron affinity of piperonal

    Institute of Scientific and Technical Information of China (English)

    MA; Jianhua; LIN; Weizhen; WANG; Wenfeng; YAO; Side

    2005-01-01

    The piperonal electron affinity was studied using pulse radiolysis technique. The electron transfer reaction process between piperonal and anthraquinone-2-sulfate was observed in the pH 7 phosphoric acid salt buffer. The transient absorption spectra of electron transfer reaction between piperonal and anthraquinone-2-sulfate were obtained, and the initial proof of the electron transfer between electron donor and acceptor was provided directly. The one-electron reduction potential of piperonal was determined to be -0.457 V.

  9. Pulse Radiolysis of Adrenaline in Acid Aqueous Solutions

    DEFF Research Database (Denmark)

    Gohn, M.; Getoff, N.; Bjergbakke, Erling

    1976-01-01

    Pulse radiolysis of adrenaline in acid aqueous solutions (pH 1–3) was carried out. The rate constants for the reactions of adrenaline with H and OH were determined: k(H + adr.) = (0·9±0·1) × 109 dm3 mol−1s−1; k(OH + adr.) = (1·65±0·15) × 1010 dm3 mol−1s−1. The H-adduct of adrenaline has two λmax...

  10. Pulse Radiolysis of Methyl Viologen in Aqueous Solutions

    DEFF Research Database (Denmark)

    Solar, S.; Solar, W.; Getoff, N.

    1982-01-01

    Pulse radiolysis of air-free aqueous methyl viologen (MV2+) solutions was carried out at various pH. The attack of e–aq on MV2+, with k(e–aq+ MV2+)= 7.5 × 1010 dm3 mol–1 s–1, leads to the formation of the long-lived radical cation (MV˙+), which possesses two absorption maxima at 392.5 nm (ε392...

  11. Redox transformations in peroxidases studied by pulse radiolysis technique

    Energy Technology Data Exchange (ETDEWEB)

    Gebicka, L.; Gebicki, J.L. (Lodz Univ. (Poland))

    1992-01-01

    By means of pulse radiolysis technique, redox processes in two heme enzymes, horseradish peroxidase (HRP) and lactoperoxidase (LPO) have been studied. It has been found that both hydrated electron and hydroxyl radical reduce HRP and LPO to their ferrous forms. The formation of compound III (an oxyform of the heme enzyme) in a two-step reaction of LPO and HRP with superoxide anion has been proposed. (author).

  12. Pulse radiolysis apparatus for monitoring at 2000 Å

    DEFF Research Database (Denmark)

    Christensen, H.C.; Nilsson, G.; Pagsberg, Palle Bjørn

    1969-01-01

    A pulse radiolysis apparatus with photometric monitoring has been built around an 11 MeV, 250 mA peak current, linac that delivers single 0.25 to 4 μsec pulses. The novel features of the apparatus include (1) a 450 W xenon lamp as the analyzing light source which in pulsed operation had a 25 times...... increased luminance; (2) a fast electronic switch that cut out the signal due to the Cerenkov radiation; (3) a secondary emission chamber that allowed the simultaneous measurement of the current and the direction of the pulsed electron beam; and (4) a system for remote controlled change of liquid samples...... stored in glass syringes. Reliable measurements of optical transmission could be made starting 0.2 μsec after the electron pulse at wavelengths down to 2000 Å on transient species having products of yield and absorptivity G×ε>500 mole (100 eV)-1.liter-1.cm-1...

  13. One-electron oxidations of ferrocenes: a pulse radiolysis study

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, Moshe; Weinraub, Dany; Broitman, Federico; DeFelippis, M.R.; Klapper, M.H.

    1988-01-01

    Using the pulse radiolysis technique we have studied the oxidation by various inorganic radicals of four water soluble ferrocene derivatives, hydroxyethyl, dimethylaminomethyl, monocarboxylic acid and dicarboxylic acid. We report the second order rate constants for these reactions, the stabilities and spectral properties of the ferrocinium products, and the electrochemically determined ferrocinium/ferrocene redox potentials. We also present preliminary estimates of tyrosine and tryptophan radical redox potentials obtained with the dicarboxylic acid ferrocene derivative as reference, and we discuss the relationship between redox potential differences and the reactivities of the ferrocenes with the inorganic radicals.

  14. One-electron oxidations of ferrocenes: A pulse radiolysis study

    Science.gov (United States)

    Faraggi, Moshe; Weinraub, Dany; Broitman, Federico; DeFelippis, Michael R.; Klapper, Michael H.

    Using the pulse radiolysis technique we have studied the oxidation by various inorganic radicals of four water soluble ferrocene derivatives, hydroxyethyl, dimethylaminomethyl, monocarboxylic acid and dicarboxylic acid. We report the second order rate constants for these reactions, the stabilities and spectral properties of the ferrocinium products, and the electrochemically determined ferrocinium/ferrocene redox potentials. We also present preliminary estimates of tyrosine and tryptophan radical redox potentials obtained with the dicarboxylic acid ferrocene derivative as reference, and we discuss the relationship between redox potential differences and the reactivities of the ferrocenes with the inorganic radicals.

  15. Pulse-Radiolysis of Aqueous KBrO4 Solutions

    DEFF Research Database (Denmark)

    Olsen, K. J.; Sehested, Knud; Appelman, L.H.

    1973-01-01

    Pulse-radiolysis of aqueous KBrO4 solutions show that BrO−4 reacts with e−aq by the reaction BrO−4 + e−aq → BrO−3 + O−. keaq + BrO−4 = (7.0 ± 0.7) × 109 M−1 sec−1. The reactions between BrO−4 and H, OH and O− are slow. The rate constants for these reactions are less than 107 M−1 sec−1.......Pulse-radiolysis of aqueous KBrO4 solutions show that BrO−4 reacts with e−aq by the reaction BrO−4 + e−aq → BrO−3 + O−. keaq + BrO−4 = (7.0 ± 0.7) × 109 M−1 sec−1. The reactions between BrO−4 and H, OH and O− are slow. The rate constants for these reactions are less than 107 M−1 sec−1....

  16. Laser Flash Photolysis and Pulse Radiolysis of Iodate and Periodate in Aqueous Solution

    DEFF Research Database (Denmark)

    Kläning, U K; Sehested, Knud; Wolff, Thomas

    1981-01-01

    Species containing iodine in oxidation state six are formed by photolysis and radiolysis of aqueous iodate and periodate solutions in the following reactions: IO3–+ O–→ IO42–; IO3–+ OH → IO3; IVII+ eaq–→ IeVI and IVII [graphic omitted] I0VI+ O–(or OH). The present pulse radiolysis and laser flash...

  17. Corrosion processes in quantized semiconductor colloids studied by pulse radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Nenadovic, M.T.; Nedeljkovic, J.M.; Micic, O.I.

    1987-04-01

    Electron-transfer reactions from different electron donors to PbSe colloids with diameter size less than 5 nm were studied by pulse-radiolysis techniques. Colloidal particles accept electrons from redox couples whose redox potentials are more negative than -0.8 V (vs. NHE). The optical properties of injected electrons show formation of Pb/sup +/ in bulk semiconductor after 1 ms and then reduction to Pb/sup 0/ in a second slower step ca. 10 s after electron injection. This cathodic corrosion process is also the dominant process during illumination of the colloids in the presence of hole scavengers. The photoreductive corrosion can be partially suppressed in the presence of an electron acceptor. Reduction reactions that cannot occur in bulk materials can occur in sufficiently small particles. Other quantized metal selenides show similar behaviour. The largest yield of hydrogen was produced with extremely small ZnSe colloids.

  18. Pulse radiolysis studies on superoxide reductase from Treponema pallidum

    CERN Document Server

    Nivière, V; Fontecave, M; Houée-Levin, C

    2015-01-01

    Superoxide reductases (SORs) are small metalloenzymes, which catalyze reduction of O2*- to H2O2. The reaction of the enzyme from Treponema pallidum with superoxide was studied by pulse radiolysis methods. The first step is an extremely fast bi-molecular reaction of the ferrous center with O2, with a rate constant of 6 x 10 (8) M(-1) s(-1). A first intermediate is formed which is converted to a second one with a slower rate constant of 4800 s(-1). This latter value is 10 times higher than the corresponding one previously reported in the case of SOR from Desulfoarculus baarsii. The reconstituted spectra for the two intermediates are consistent with formation of transient iron-peroxide species.

  19. Pulse radiolysis and spectrophotometric studies on the binding of organic cations with heparin

    Science.gov (United States)

    Jakubowska, Małgorzata; Adamus, Jan; Gębicki, Jerzy; Marcinek, Andrzej; Sikora, Adam

    2014-06-01

    Here we present the spectroscopic and pulse radiolysis studies of the interactions of heparin and some organic cations:methylene blue (MB), 1-methylnicotinamide (MNA+), and its dimer 1,3-bis(1-methylnicotinamide)propane (bis(MNA+)).

  20. Improvements in detection system for pulse radiolysis facility

    CERN Document Server

    Rao, V N; Manimaran, P; Mishra, R K; Mohan, H; Mukherjee, T; Nadkarni, S A; Sapre, A V; Shinde, S J; Toley, M

    2002-01-01

    This report describes the improvements made in the detection system of the pulse radiolysis facility based on a 7 MeV Linear Electron Accelerator (LINAC) located in the Radiation Chemistry and Chemical Dynamics Division of Bhabha Atomic Research Centre. The facility was created in 1986 for kinetic studies of transient species whose absorption lies between 200 and 700 nm. The newly developed detection circuits consist of a silicon (Si) photodiode (PD) detector for the wavelength range 450-1100 nm and a germanium (Ge) photodiode detector for the wavelength range 900-1600 nm. With these photodiode-based detection set-up, kinetic experiments are now routinely carried out in the wavelength range 450-1600 nm. The performance of these circuits has been tested using standard chemical systems. The rise time has been found to be 150 ns. The photo-multiplier tube (PMT) bleeder circuit has been modified. A new DC back-off circuit has been built and installed in order to avoid droop at longer time scales. A steady baselin...

  1. Pulse-radiolysis study of cytochrome c/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    van Leeuwen, W.; van Dijk, C.; Grande, H.J.; Veeger, C.

    1982-10-02

    Pulse-radiolysis experiments were performed in the presence of methyl viologen and cytochrome c/sub 3/. After the pulse, methyl viologen radicals are formed and the kinetics of these radicals with cytochrome c/sub 3/ are studied. The reaction between cytochrome c/sub 3/ and methyl viologen radicals (MV/sup +/) is diffusion controlled. The ionic strength dependence and the pH-dependence of this reaction were studied. From the ionic strength dependence (at pH 7.8) we found that the net charge of the fully oxidized cytochrome c/sub 3/ molecule was Z = +4.7 +- 0.7. After the pulse an equilibrium is reached for the reaction of MV/sup +/ with cytochrome c/sub 3/. From this equilibrium an apparent midpoint potential can be obtained. The apparent midpoint potential of this multihaem molecule was found to depend on the degree of reduction, ..cap alpha... With the help of the Nernst equation an empirical equation is obtained to describe this dependence of the midpoint potential: E/sub 0/ = -0.250-0.088 x (in V). An estimation is made of the energy of interaction between the haems due to electrostatic interactions (..delta..epsilon < 32 mV) and due to ionic strength effects (-12 mV < ..delta..epsilon < 26 mV). The results suggest that the redox properties of the individual haems in the cytochrome c/sub 3/ molecule are dependent on the degree of reduction of the other haems in the molecule. The reaction of cytochrome c/sub 3/ with MV/sup +/ or with ethanol radicals (EtOHsup(.)) has been compared with the reactions of horse-heart cytochrome c and of metmyoglobin with the same radicals. The reaction of MV/sup +/ or EtOHsup(.) with horse-heart cytochrome c is found to be diffusion controlled; the reactions with metmyoglobin on the other hand are most probably controlled by an activation energy.

  2. Pulse radiolysis of butyl acrylate in aqueous solution

    Science.gov (United States)

    Kujawa, P.; Mohid, N.; Zaman, K.; Manshol, W.; Ulanski, P.; Rosiak, J. M.

    1998-10-01

    The pulse radiolysis of n-butyl acrylate (nBA) in aqueous solution was studied. The rate constant of the reaction of nBA with hydroxyl radicals was calculated as 1.5×10 10 dm 3 mol -1 s -1. The absorption spectrum of the OH ·-nBA adduct appeared to have a broad maximum at 300 nm. This spectrum was attributed to the α-carbon centred radicals. It decayed with the first-order rate constant k=1.5×10 4 s -1 (pH 10.8). The rate constant of the nBA reaction with hydrated electrons was determined as k=1.6×10 10 dm 3 mol -1 s -1. The spectrum of H ·-nBA adduct was similar to that recorded for OH · adduct. It decayed with first-order kinetics at k=1.0×10 4 s -1. Spectra of the electron adduct were characterised by the band with a maximum at 285 nm (pH 10.0) or at 280 nm (pH 4.0) with ɛ=10 500 dm 3 mol -1 cm -1. In acidic solution, radical anion formed upon addition of hydrated electrons to the nBA molecule, undergoes fast, reversible protonation. The decay of the reversibly protonated electron adduct was a second-order process at k=2.5×10 9 dm 3 mol -1 s -1. This reaction took place at the carbonyl oxygen. Slow, irreversible protonation of the electron adduct at high pH takes place at the β-carbon atom at k=2.9×10 4 s -1.

  3. Radiolytic reactions of nitro blue tetrazolium under oxidative and reductive conditions: a pulse radiolysis study

    Science.gov (United States)

    Kovacs, A.; Wojnarovits, L.; Baranyai, M.; Moussa, A.; Othman, I.; McLaughlin, W. L.

    1999-08-01

    The radiolytic reactions of the ditetrazolium salt nitro blue tetrazolium chloride (NBTCl 2) were studied by pulse radiolysis technique in aqueous solution under reducing and oxidising conditions with the aim of potential dosimetry application. Under reducing conditions the fast formation of the tetrazolinyl radical is observed that is followed by the appearance of monoformazan (MF +), i.e. one of the tetrazolium rings is reduced to formazan. The formation of the water-insoluble diformazan, i.e. the result of the second reduction step was not observed in pulse radiolysis. Formazan formation was not found under oxidative conditions.

  4. A pulse radiolysis study of the dynamics of ascorbic acid free radicals within a liposomal environment.

    Science.gov (United States)

    Kobayashi, Kazuo; Seike, Yumiko; Saeki, Akinori; Kozawa, Takahiro; Takeuchi, Fusako; Tsubaki, Motonari

    2014-10-06

    The dynamics of free-radical species in a model cellular system are examined by measuring the formation and decay of ascorbate radicals within a liposome with pulse radiolysis techniques. Upon pulse radiolysis of an N2O-saturated aqueous solution containing ascorbate-loaded liposome vesicles, ascorbate radicals are formed by the reaction of OH(·) radicals with ascorbate in unilamellar vesicles exclusively, irrespective of the presence of vesicle lipids. The radicals are found to decay rapidly compared with the decay kinetics in an aqueous solution. The distinct radical reaction kinetics in the vesicles and in bulk solution are characterized, and the kinetic data are analyzed.

  5. Development of high-voltage pulse-slicer unit with variable pulse duration for pulse radiolysis system

    Science.gov (United States)

    Upadhyay, J.; Sharma, M. L.; Navathe, C. P.; Toley, M. A.; Shinde, S. J.; Nadkarni, S. A.; Sarkar, S. K.

    2012-02-01

    A high-voltage pulse-slicer unit with variable pulse duration has been developed and integrated with a 7 MeV linear electron accelerator (LINAC) for pulse radiolysis investigation. The pulse-slicer unit provides switching voltage from 1 kV to 10 kV with rise time better than 5 ns. Two MOSFET based 10 kV switches were configured in differential mode to get variable duration pulses. The high-voltage pulse has been applied to the deflecting plates of the LINAC for slicing of electron beam of 2 μs duration. The duration of the electron beam has been varied from 30 ns to 2 μs with the optimized pulse amplitude of 7 kV to get corresponding radiation doses from 6 Gy to 167 Gy.

  6. Reactivity of OH and O– with aqueous methyl viologen studied by pulse radiolysis

    DEFF Research Database (Denmark)

    Solar, Sonja; Solar, Wolfgang; Getoff, Nikola

    1985-01-01

    The behaviour of aqueous MV2+ towards oxidizing radicals (OH and O–) has been investigated in the pH range from 6 to 14 by means of pulse radiolysis. A semi-linear optimization method was applied for resolving the complex reaction mechanism. In the pH range from 6 to 8 the rate constant for attac...

  7. Radiation-induced pink nickel oligomeric clusters in water. Pulse radiolysis study.

    Science.gov (United States)

    Hioul, Mohamed Larbi; Lin, Mingzhang; Belloni, Jacqueline; Keghouche, Nassira; Marignier, Jean-Louis

    2014-10-09

    γ-rays and pulse radiolysis of aqueous solutions of Ni(2+) ions in the presence of polyacrylate (PA(-)) and 2-propanol leads to the formation of metastable species absorbing at 540 nm that are ascribed to "pink" oligomeric clusters of a few nickel atoms only. The molar absorption coefficient is evaluated as ε540 nm = 3300 ± 300 L mol(-1) cm(-1) per Ni(0) atom. The successive steps from the reduction of Ni(2+) into Ni(+) ions to the formation of the pink clusters at 540 nm under conditions of complexation by PA(-) are investigated by pulse radiolysis. The yield of the formation of pink clusters increases markedly with the irradiation dose rate, demonstrating the occurrence of the disproportionation of the [Ni(+), PA(-)] complex after a single electron pulse. The reduction and nucleation mechanisms, including rate constants, in competition with the back oxidation by protons, particularly at low dose rate, are discussed.

  8. Development of nanosecond time-resolved infrared detection at the LEAF pulse radiolysis facility

    Energy Technology Data Exchange (ETDEWEB)

    Grills, David C., E-mail: dcgrills@bnl.gov; Farrington, Jaime A.; Layne, Bobby H.; Preses, Jack M.; Wishart, James F. [Chemistry Department, Brookhaven National Laboratory, P.O. Box 5000, Upton, New York 11973-5000 (United States); Bernstein, Herbert J. [Department of Mathematics and Computer Science, Dowling College, 1300 William Floyd Parkway, Shirley, New York 11967 (United States)

    2015-04-15

    When coupled with transient absorption spectroscopy, pulse radiolysis, which utilizes high-energy electron pulses from an accelerator, is a powerful tool for investigating the kinetics and thermodynamics of a wide range of radiation-induced redox and electron transfer processes. The majority of these investigations detect transient species in the UV, visible, or near-IR spectral regions. Unfortunately, the often-broad and featureless absorption bands in these regions can make the definitive identification of intermediates difficult. Time-resolved vibrational spectroscopy would offer much improved structural characterization, but has received only limited application in pulse radiolysis. In this paper, we describe in detail the development of a unique nanosecond time-resolved infrared (TRIR) detection capability for condensed-phase pulse radiolysis on a new beam line at the LEAF facility of Brookhaven National Laboratory. The system makes use of a suite of high-power, continuous wave external-cavity quantum cascade lasers as the IR probe source, with coverage from 2330 to 1051 cm{sup −1}. The response time of the TRIR detection setup is ∼40 ns, with a typical sensitivity of ∼100 μOD after 4-8 signal averages using a dual-beam probe/reference normalization detection scheme. This new detection method has enabled mechanistic investigations of a range of radiation-induced chemical processes, some of which are highlighted here.

  9. Development of nanosecond time-resolved infrared detection at the LEAF pulse radiolysis facility.

    Science.gov (United States)

    Grills, David C; Farrington, Jaime A; Layne, Bobby H; Preses, Jack M; Bernstein, Herbert J; Wishart, James F

    2015-04-01

    When coupled with transient absorption spectroscopy, pulse radiolysis, which utilizes high-energy electron pulses from an accelerator, is a powerful tool for investigating the kinetics and thermodynamics of a wide range of radiation-induced redox and electron transfer processes. The majority of these investigations detect transient species in the UV, visible, or near-IR spectral regions. Unfortunately, the often-broad and featureless absorption bands in these regions can make the definitive identification of intermediates difficult. Time-resolved vibrational spectroscopy would offer much improved structural characterization, but has received only limited application in pulse radiolysis. In this paper, we describe in detail the development of a unique nanosecond time-resolved infrared (TRIR) detection capability for condensed-phase pulse radiolysis on a new beam line at the LEAF facility of Brookhaven National Laboratory. The system makes use of a suite of high-power, continuous wave external-cavity quantum cascade lasers as the IR probe source, with coverage from 2330 to 1051 cm(-1). The response time of the TRIR detection setup is ∼40 ns, with a typical sensitivity of ∼100 μOD after 4-8 signal averages using a dual-beam probe/reference normalization detection scheme. This new detection method has enabled mechanistic investigations of a range of radiation-induced chemical processes, some of which are highlighted here.

  10. Repair effect of thymine radical anion by echinocoside using pulse radiolysis

    Institute of Scientific and Technical Information of China (English)

    李雯艳; 郑荣梁; 赵松岭; 姜岳; 林念芸

    1996-01-01

    Repair activities of thymine radical anion by echinocoside, isolated from Pedicularis plicata. were studied using pulse radiolysis technique. The thymine radical anion was produced by the reaction of hydrated electron with thymine. Echinocoside. one of the polyphenols of phenylpropanoid glycoside, was added to the thymine aqueous solution saturated with N2. Kinetic analysis by transient absorption spectrum showed that thymine radical anion was formed at first, and then after several decades of microseconds of pulse radiolysis. the spectrum of thymine radical anion was changed to that of echinocoside radical anion. The evidence indicated that thymine radical anion was repaired through one-electron-transfer between the DNA base radical anion and echinocoside. The rate constant of electron transfer by echinocoside was 1.45× 109 dm3 · mol1 · s 1.

  11. The generation and spectral characterization of oligothiophenes radical cations. A pulse radiolysis investigation

    Energy Technology Data Exchange (ETDEWEB)

    Emmi, S.S. [Istituto FRAE of CNR, Via P. Gobetti 101, 40129 Bologna (Italy); D' Angelantonio, M. [Istituto FRAE of CNR, Via P. Gobetti 101, 40129 Bologna (Italy); Beggiato, G. [Istituto FRAE of CNR, Via P. Gobetti 101, 40129 Bologna (Italy); Poggi, G. [Dipartimento ' G. Ciamician' , Universita di Bologna, Via Selmi 2, 40126 Bologna (Italy); Geri, A. [Istituto FRAE of CNR, Via P. Gobetti 101, 40129 Bologna (Italy); Pietropaolo, D. [Istituto ICOCEA of CNR, Via P. Gobetti 101, 40129 Bologna (Italy); Zotti, G. [Istituto IPELP of CNR, C.so Stati Uniti 4, 35020 Padova (Italy)

    1999-03-01

    Conjugated polymers and oligomers of thiophene have been employed in a number of electronic devices due to the change in their conductivity by several orders of magnitude when oxidized to their cationic states. The radical cations of oligothiophenes (nT), with number of rings n=1-6, have been produced by pulse radiolysis for the first time and their spectra have been characterized. Electronic structure and transition energies are briefly discussed in the light of semiempirical theoretical calculations.

  12. Study on geminate ion recombination in liquid dodecane using pico- and subpicosecond pulse radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Saeki, Akinori E-mail: saeki03@sanken.osaka-u.ac.jp; Kozawa, Takahiro; Yoshida, Yoichi; Tagawa, Seiichi

    2001-07-01

    Geminate ion recombination was studied by the laser-synchronized pulse radiolysis system which was developed at Osaka University. The time-dependent behavior of the cation radicals in liquid n-dodecane on picosecond time scale showed a typical geminate decay. The experimental data were compared with the theoretical decay based on the diffusion theory with the convolution technique in the time region within 1 ns. (author)

  13. Pulse radiolysis of liquid water using picosecond electron pulses produced by a table-top terawatt laser system

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Ned [Center for Ultrafast Optical Science, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109-2099 (United States); Flippo, Kirk [Center for Ultrafast Optical Science, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109-2099 (United States); Nemoto, Koshichi [Center for Ultrafast Optical Science, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109-2099 (United States); Umstadter, Donald [Center for Ultrafast Optical Science, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, Michigan 48109-2099 (United States); Crowell, Robert A. [Chemistry Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Jonah, Charles D. [Chemistry Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Trifunac, Alexander D. [Chemistry Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2000-06-01

    A laser based electron generator is shown, for the first time, to produce sufficient charge to conduct time resolved investigations of radiation induced chemical events. Electron pulses generated by focussing terawatt laser pulses into a supersonic helium gas jet are used to ionize liquid water. The decay of the hydrated electrons produced by the ionizing electron pulses is monitored with 0.3 {mu}s time resolution. Hydrated electron concentrations as high as 22 {mu}M were generated. The results show that terawatt lasers offer both an alternative to linear accelerators and a means to achieve subpicosecond time resolution for pulse radiolysis studies. (c) 2000 American Institute of Physics.

  14. An Advantage of the Equivalent Velocity Spectroscopy for Femtsecond Pulse Radiolysis

    CERN Document Server

    Kondoh, Takafumi; Tagawa, Seiichi; Tomosada, Hiroshi; Yang Jin Feng; Yoshida, Yoichi

    2005-01-01

    For studies of electron beam induced ultra-fast reaction process, femtosecond(fs) pulse radiolysis is under construction. To realize fs time resolution, fs electron and analyzing light pulses and their jitter compensation system are needed. About a 100fs electron pulse was generated by a photocathode RF gun linac and a magnetic pulse compressor. Synchronized Ti: Sapphire laser have a puleswidth about 160fs. And, it is significant to avoid degradation of time resolution caused by velocity difference between electron and analyzing light in a sample. In the 'Equivalent velocity spectroscopy' method, incident analyzing light is slant toward electron beam with an angle associated with refractive index of sample. Then, to overlap light wave front and electron pulse shape, electron pulse shape is slanted toward the direction of travel. As a result of the equivalent velocity spectroscopy for hydrated electrons, using slanted electron pulse shape, optical absorption rise time was about 1.4ps faster than normal electro...

  15. A study on scavenging effects of Chinese medicine on superoxide anion radicals by pulse radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Li Fengmei; Liu Andong; Gu Hongchun; Di Shaojie (Beijing Normal Univ., BJ (China). Inst. of Low Energy Nuclear Physics)

    A study on scavenging and dismutation effects on superoxide anion radical ([center dot]O[sub 2][sup -]) using two Chinese antiaging medicines - Salvia miltiorrhiza injection (S.M.) and Sulekang capsule (S.C.) was carried out using pulse radiolysis. The absorption spectra of [center dot] OH[sub 2][sup -] was redetermined by radiolysis of an aqueous solution of sodium format. The absorption maximum is at about 250 nm. The results suggested that S.M. and S.C. can dismutate and scavenge [center dot]O[sub 2][sup -]. The experimental scavenging rates of S.M. (150[mu]g/ml) and S.C. (250[mu]g/ml) were 89.6% and 69.5% respectively. (author).

  16. Absorbed Dose Distribution in a Pulse Radiolysis Optical Cell

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    When a liquid solution in an optical cell is irradiated by an intense pulsed electron beam, it may be important in the chemical analysis of the solution to know the distribution of energy deposited throughout the cell. For the present work, absorbed dose distributions were measured by thin...

  17. Improvements in time resolution and signal-to-noise ratio in a compact pico-second pulse radiolysis system

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, Hiroyuki [Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikuicho, Shinjuku-ku, Tokyo 162-0044 (Japan)], E-mail: physik-albert@suou.waseda.jp; Kawaguchi, Masaaki; Sakaue, Kazuyuki; Komiya, Keita; Nomoto, Tomoaki; Kamiya, Yoshio; Hama, Yoshimasa; Washio, Masakazu [Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikuicho, Shinjuku-ku, Tokyo 162-0044 (Japan); Ushida, Kiminori [The Institute of Physical and Chemical Research, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Kashiwagi, Shigeru [The Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Kuroda, Ryunosuke [National Institute of Advanced Industrial Science and Technology, AIST Tsukuba Central 2, Tsukuba, Ibaraki 305-8568 (Japan)

    2007-12-15

    A compact pico-second pulse radiolysis system has been developing at Waseda University for studying primary processes in radiation chemistry. The system is composed of a photo-injector system and a pico-second all-solid-state laser system. An infrared (IR) and an ultraviolet (UV) laser pulses are obtained from mode-locked Nd:YLF laser system and used for generation of the white light continuum as a probe light and the irradiation to the Cu cathode of a photo-cathode RF-gun, respectively. To improve signal-to-noise (S/N) ratio and time resolution of this pulse radiolysis system, we optimized both probe light and pump electron beam. As a result, our pico-second pulse radiolysis system has been enough to study the primary processes of radiation chemistry. The experimental results and the improvements of our system are described in this paper.

  18. Pulse Radiolysis at High Temperatures and High Pressures

    DEFF Research Database (Denmark)

    Christensen, H.; Sehested, Knud

    1980-01-01

    A cell for pulse radiolytic measurements up to temperatures of 320°C and pressures of 14 MPa is constructed. The activation energy of the reaction OH + Cu2+ is determined to 13.3 kJ × mol−1 (3.2 kcal × mol−1). A preliminary study of the reaction e−aq + e−aq yields an activation energy of 22 kJ × ...

  19. Electron transfer in N-butylpyridinium tetrafluoroborate ionic liquid by pulse radiolysis

    Institute of Scientific and Technical Information of China (English)

    FU HaiYing; XING ZhaoGuo; CAO XiYan; WU GuoZhong

    2013-01-01

    The radiolysis behavior of neat pyridinium ionic liquids (ILs) and their aqueous solutions was investigated using nanosecond pulse radiolysis techniques.Radiolysis of the ionic liquids,such as N-butylpyridinium tetrafluoroborate (BuPyBF4),resulted in the formation of solvated electrons and organic radicals.Solvated electrons reacted with the pyridinium moiety to produce a pyridinyl radical,which can transfer electrons to various acceptors.The electron-transfer rate constants of the solvent-derived butylpyridinyl radicals in BuPyBF4 and in several compounds (for example,duroquinone,4,4'-pyridine,benzophenone,and 1,1'-dimethyl-4,4'-bypyridinium dichloride) (k of the order 108 L/(mol s) were lower than those measured in water and in i-PrOH but were significantly higher than the diffusion-controlled rate constants estimated based on viscosity.The electron-transfer rate constants in neat BuPyBF4 were one order of magnitude faster than the diffusion-controlled values.This finding suggests that BuPyBF4 acts not only as solvent but also as active solute,such as in solvent-mediated reactions.These reactions result in electrons reaching their final destinations via intervening pyridinium groups without requiring the diffusion of a specific radical.

  20. Time resolved ESR spectroscopy. ESR pulse radiolysis equipment with microsecond time resolution

    Energy Technology Data Exchange (ETDEWEB)

    Beckert, D.; Mehler, K. (Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1983-01-01

    Time resolved ESR experiments allow the study of the chemical kinetics as well as spin dynamics of free radicals in the liquid phase. Starting from the physical and chemical requirements the experimental parameters of a universal time resolved ESR spectrometer are derived. The main components of the ESR pulse radiolysis equipment are described and their technical parameters are discussed. By two experimental examples it is shown that at a time resolution of 0.3 ..mu..s a sensitivity of c/sub min/ = 10/sup -6/ mol dm/sup -3/ for simple radical spectra can be achieved.

  1. Use of pulse radiolysis for the study of the chemistry of aqueous ozone and ozonide solutions

    DEFF Research Database (Denmark)

    Sehested, Knud; Holcman, Jerzy; Bjergbakke, Erling

    1986-01-01

    The chemistry of aqeous ozone, O3, and ozonide, O3−, is of great interest from a technological, environmental and scientific point of view. The literature about their aqueous chemistry is extensive, the reaction mechanisms are still not well understood. The ozonide anion is a free radical...... of a detailed mechanism. We have investigated the reaction mechanisms using pulse radiolysis in combination with a high pressure cell, rapid mixing and numerical simulation of the experiments. This study makes it possible to give a detailed description of the reaction mechanisms in terms of uni- and bimolecular...... reactions and provides kinetic data sufficient for computer simulations of aqueous O3/O3− chemistry....

  2. Pulse radiolysis and cyclic voltammetry studies of redox properties of phenothiazine radicals

    Energy Technology Data Exchange (ETDEWEB)

    Madej, Edyta [Gray Cancer Institute, PO Box 100, Mount Vernon Hospital, Northwood, Middlesex HA6 2JR (United Kingdom)]. E-mail: madej@gci.ac.uk; Wardman, Peter [Gray Cancer Institute, PO Box 100, Mount Vernon Hospital, Northwood, Middlesex HA6 2JR (United Kingdom)

    2006-09-15

    One-electron transfer equilibria between seven phenothiazines were characterized by pulse radiolysis, producing radical-cations via oxidation by Br{sub 2} {sup .-} or (SCN){sub 2} {sup .-} radicals. The reduction potentials of the phenothiazine radicals were determined by cyclic voltammetry. As an independent check, the redox equilibrium between one phenothiazine and the redox indicator ABTS was investigated. The data establish phenothiazines as useful indicators for radical redox properties. However, there are potential problems of aggregation, additional reactions with Br{sup -}/Br{sub 2} {sup .-} and reactivity of the radicals towards buffers or other nucleophiles.

  3. The reduction process of phytic acid silver ion system: A pulse radiolysis study

    Science.gov (United States)

    Joshi, Ravi; Mukherjee, Tulsi

    2007-05-01

    Reduction of silver ion in a silver-phytic acid (1:1 ratio) system has been studied using pulse radiolysis technique. Time-resolved transformation of the intermediates, Ag +→Ag 0→Ag 2+→Ag 32+, has been clearly observed in the reduction of silver-phytic acid (1:1) system. The effect of phytic acid on the formation and decay of initial silver clusters has been also studied. The surface plasmon absorption band of stable silver nanoparticle (410 nm) and dynamic light scattering technique has been used to characterize the nanoparticles and measure the average size ( Rav=100 nm).

  4. Reaction of hydroxyl radical with phenylpropanoid glycosides from Pedicularis species: a pulse radiolysis study

    Institute of Scientific and Technical Information of China (English)

    王潘奋; 郑荣梁; 高建军; 贾忠建; 王文峰; 姚思德; 张加山; 林念芸

    1996-01-01

    Using pulse radiolysis technique, the reaction between hydroxyl radical and 7 phenylpropanoidglycosides: echinacoside, verbascoside, leucosceptoside A, martynoside, pediculariosides A, M and N which were isolated from Pedicularis were examined. The rate constants of these reactions were determined by transient absorption spectra. All 7 phenylpropanoid glycosides react with hydroxyl radical at high rate constants within (0.97-1.91)×1010L · mol-1 · s-1. suggesting that they are effective hydroxyl radical scavengers. The results demonstrate that the numbers of phenolic hydroxyl groups of phenylpropanoid glycosides are directly related to their scavenging activities. The scavenging activities are likely related to o-dihydroxy group of phenylpropanoid glycosides as well.

  5. Reaction of carotenoids with CCl3OO· by using pulse radiolysis

    Institute of Scientific and Technical Information of China (English)

    ZHAO; Wenen; (赵文恩); YAO; Side; (姚思德); WANG; Qiang; (王强); QIAN; Suping; (钱素平); WANG; Wenfeng; (王文峰); HAN; Yashan; (韩雅珊)

    2003-01-01

    The interactions of carotenoids (bixin, β-carotene and lycopene) with CCl3OO@ in aqueous and i-propylalcohol solution saturated with air have been studied by pulse radiolysis. For bixin and β-carotene reaction products from forming process, absorbing in the region of 650 nm, is observed with concomitant carotenoid bleaching (bixin at 500 nm, β-carotene at 450 nm). Their rate constants from forming process are 1.78×108 and 7.8×107 mol-1@L@s-1 respectively. However, in the case of lycopene, no such a forming process of reaction as bixin and β-carotene can be observed although there is the bleaching reaction (rate constant 4×107 mol-1@L@s-1). The results suggest that the carotenoid radical cationand an additional radical are produced in the case of bixin and β-carotene, whereas lycopene undergoes electron transfer with CCl3OO@, forming cation radical.

  6. The reduction process of phytic acid-silver ion system: A pulse radiolysis study

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Ravi [Radiation and Photochemistry Division, Chemistry Group, Bhabha Atomic Research Center, Mumbai 400 085 (India)]. E-mail: rjudrin@yahoo.com; Mukherjee, Tulsi [Radiation and Photochemistry Division, Chemistry Group, Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2007-05-15

    Reduction of silver ion in a silver-phytic acid (1:1 ratio) system has been studied using pulse radiolysis technique. Time-resolved transformation of the intermediates, Ag{sup +{yields}}Ag{sup 0{yields}}Ag{sub 2} {sup +{yields}}Ag{sub 3} {sup 2+}, has been clearly observed in the reduction of silver-phytic acid (1:1) system. The effect of phytic acid on the formation and decay of initial silver clusters has been also studied. The surface plasmon absorption band of stable silver nanoparticle (410 nm) and dynamic light scattering technique has been used to characterize the nanoparticles and measure the average size (R {sub av}=100 nm)

  7. Mechanism and kinetics in reactions of caffeic acid with radicals by pulse radiolysis and calculation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xifeng; Cai, Zhongli; Katsumura, Yosuke [Tokyo Univ., Tokai, Ibaraki (Japan). Nuclear Engineering Research Lab

    2000-03-01

    The interaction of caffeic acid with e{sub aq}{sup -}, (CH{sub 3}){sub 2}(OH) CCH{sub 2}{sup {center_dot}}, CO{sub 2}{sup {center_dot}}{sup -}, H{sup {center_dot}}, {center_dot}OH and N{sub 3}{sup {center_dot}} radicals were studied by {gamma}-, pulse radiolysis and molecular orbital calculation. UV-visible spectra of electron/{center_dot}OH adducts, semi-quinone radicals of caffeic ions, and the stable products from the reactions were derived. The rate constants were determined. The attacked sites and the most favorable structures of the transient radicals were predicted. Reaction mechanisms were proposed. (author)

  8. Spectroscopic characterization of mechanisms of oxidation of Phe by SO4- radical: A pulse radiolysis study

    Institute of Scientific and Technical Information of China (English)

    储高升; 韩镇辉; 都志文; 张淑娟; 姚思德; 张志成

    2002-01-01

    By using time-resolved kinetic spectrophotometry and pulse radiolysis technique, the oxidation of Phe by SO4- radical has been investigated both in aqueous and water/acetonitrilemixed solutions. The results reveal that attack of the oxidizing SO4- radical on Phe leads directlyto the formation of Phe cation radical 3 with a strong absorption peak at 310 nm, then it proceeds in three competitive reactions via either hydroxylation, deprotonation or decarboxylation, which were found to be strongly dependent upon the ionization state of the substitutes -COOH and -NH2 and the nature of the solvents. Decarboxylation takes place only when the carboxyl group is deprotonated. At high pH deprotonation of Phe cation radical 3 is much easier to occur than that in neutral or acid solutions. Moreover, with addition of acetonitrile, deprotonation is more predominant than hydroxylation, whereas in aqueous solutions hydroxylation is much easier to occur.

  9. Spectroscopic characterization of mechanisms of oxidation of Phe by SO.-4 radical: A pulse radiolysis study

    Institute of Scientific and Technical Information of China (English)

    储高升; 张淑娟; 姚思德; 韩镇辉; 都志文; 张志成

    2002-01-01

    By using time-resolved kinetic spectrophotometry and pulse radiolysis technique, the oxidation of Phe by radical has been investigated both in aqueous and water/acetonitrile mixed solutions. The results reveal that attack of the oxidizing SO4-radical on Phe leads directly to the formation of Phe cation radical 3 with a strong absorption peak at 310 nm, then it proceeds in three competitive reactions via either hydroxylation, deprotonation or decarboxylation, which were found to be strongly dependent upon the ionization state of the substitutes -COOH and -NH2 and the nature of the solvents. Decarboxylation takes place only when the carboxyl group is deprotonated. At high pH deprotonation of Phe cation radical 3 is much easier to occur than that in neutral or acid solutions. Moreover, with addition of acetonitrile, deprotonation is more predominant than hydroxylation, whereas in aqueous solutions hydroxylation is much easier to occur.

  10. Pulse radiolysis study on the free radical scavenging activities of puerarin

    Institute of Scientific and Technical Information of China (English)

    赵亚平; 王文锋; 于文利; 姚思德; 钱素平; 王大璞

    2003-01-01

    The free radical scavenging activities of puerarin towards nitrogen dioxide radicals , nitric oxide radicals (NO·) and hydroxyl radicals (OH·) were investigated by pulse radiolysis. Puerarin reacted with or NO·to form puerarin-4-O· with the absorption maximum at 340 nm, but reacted with OH·to form at least three transient species including puerarin-2-O·, puerarin-4-O· and [puerarin-OH]· with a broad absorption spectrum band (300-750 nm). In addition, the reaction rate constants of puerarin reacting with , NO·, and OH· were determined as 2.6×108, 1.7×108 and 3.9×109 L@mol·1@s·1, respectively.

  11. Direct optical observation of the formation of some aliphatic alcohol radicals. A pulse radiolysis study

    Indian Academy of Sciences (India)

    E Janata

    2002-12-01

    The kinetics of the reactions of hydroxyl radicals and hydrogen atoms with some aliphatic alcohols in aqueous solutions were studied using pulse radiolysis. Based on the increase in optical absorption in the UV region, the rate constants for the reaction of hydroxyl radicals and hydrogen atoms with methanol, ethanol, 2-propanol or -butyl alcohol were determined to be 9.0 × 108, 2.2 × 109, 2.0 × 109, 6.2 × 108 and 1.1 × 106, 1.8 × 107, 5.3 × 107, 2.3 × 105 dm3 mol-1 s-1 respectively. The bimolecular decay rate constants for the alcohol radicals produced in methanol and ethanol were evaluated to be 2 .4 × 109 and 1.5 × 109 dm3 mol-1 s-1. The values observed are in fairly good agreement with those reported earlier.

  12. Competition reactions of H2O•+ radical in concentrated Cl- aqueous solutions: picosecond pulse radiolysis study.

    Science.gov (United States)

    El Omar, Abdel Karim; Schmidhammer, Uli; Rousseau, Bernard; LaVerne, Jay; Mostafavi, Mehran

    2012-11-29

    Picosecond pulse-probe radiolysis measurements of highly concentrated Cl(-) aqueous solutions are used to probe the oxidation mechanism of the Cl(-). The transient absorption spectra are measured from 340 to 710 nm in the picosecond range for the ultrafast electron pulse radiolysis of halide solutions at different concentrations up to 8 M. The amount of Cl(2)(•-) formation within the electron pulse increases notably with increasing Cl(-) concentration. Kinetic measurements reveal that the direct ionization of Cl(-) cannot solely explain the significant amount of fast Cl(2)(•-) formation within the electron pulse. The results suggest that Cl(-) reacts with the precursor of the OH(•) radical, i.e., H(2)O(•+) radical, to form Cl(•) atom within the electron pulse and the Cl(•) atom reacts subsequently with Cl(-) to form Cl(2)(•-) on very short time scales. The proton transfer reaction between H(2)O(•+) and the water molecule competes with the electron transfer reaction between Cl(-) and H(2)O(•+). Molecular dynamics simulations show that number of water molecules in close proximity decreases with increasing concentration of the salt (NaCl), confirming that for highly concentrated solutions the proton transfer reaction between H(2)O(•+) and a water molecule becomes less efficient. Diffusion-kinetic simulations of spur reactions including the direct ionization of Cl(-) and hole scavenging by Cl(-) show that up to 30% of the H(2)O(•+) produced by the irradiation could be scavenged for solutions containing 5.5 M Cl(-). This process decreases the yield of OH(•) radical in solution on the picosecond time scale. The experimental results for the same concentration of Cl(-) at a given absorbed dose show that the radiation energy absorbed by counterions is transferred to Cl(-) or water molecules and the effect of the countercation such as Li(+), K(+), Na(+), and Mg(2+) on the oxidation yield of Cl(-) is negligible.

  13. Pulse radiolysis of alkanes: A time-resolved electron paramagnetic resonance study

    Energy Technology Data Exchange (ETDEWEB)

    Shkrob, I.A.; Trifunac, A.D. [Argonne National Lab., IL (United States). Chemistry Division

    1994-02-14

    Time-resolved spin-echo-detected electron paramagnetic resonance (EPR) was applied to examine short-lived alkyl radicals formed in pulse radiolysis of liquid alkanes. It was found that the ratio of yields of penultimate and interior radicals in n-alkanes at the instant of their generation is temperature-independent and is ca. 1.25 times greater than the statistical quantity. This higher-than-statistical production of penultimate radicals indicates that the fast ion molecule reactions involving radical cations are a significant route of radical generation. The analysis of spin-echo kinetics in n-alkanes suggests that the alkyl radicals are emissively polarized in spur reactions. this initial polarization rapidly increases with shortening of the aliphatic chain. Another finding is that a long-chain structure of these radicals results in much higher rate of Heisenberg spin exchange relative to the recombination rate. The relative yields of hydrogen abstraction and fragmentation for various branched alkanes are estimated. It is concluded that the fragmentation occurs prior to the formation of radicals in an excited precursor species. Effects of phenolic and alkene additives in radiolysis of n-alkanes are examined. It is demonstrated that phenoxy radicals are produced in dissociative capture of electrons and alkane holes. Another route is a reaction of phenols with free hydrogen atoms. A rapid transfer of singlet correlation from the geminate radical ion pairs is responsible for unusual polarization patterns in the phenoxy and cyclohexadienyl radicals. The significance of these results in the context of cross-linking in polyethylene and higher paraffins is discussed. 56 refs.

  14. Reaction of a hydrated electron with gentamycin and collagen -a pulse radiolysis study

    Energy Technology Data Exchange (ETDEWEB)

    Pietrucha, K. [Technical Univ., Lodz (Poland). Inst. of Applied Radiation Chemistry; Gora, L. [Worcester Poltechnic Inst., MA (United States). Dept. of Chemical Engineering; Doillon, C.J. [Laval Univ., Quebec, PQ (Canada). Dept. of Surgery]|[Saint-Francois d`Assise Hospital, Quebec (Canada)

    1996-01-01

    The reactions of a hydrated electron (e{sub aq}{sup -}) with aminoglycoside antibiotic gentamycin and collagen in aqueous medium at different pH have been investigated employing a pulse radiolysis technique. The pseudo-first order equation of reaction kinetics was used to give an accurate description of the decay of e{sub aq}{sup -} in gentamycin solutions. The rate constant of the e{sub aq}{sup -}decay in collagen solutions was high and reached 3.2 x 10{sup 10} M{sup -1} s{sup -1}. The rate constants for the reaction of the e{sub aq}{sup -}with gentamycin were found to be influenced by pH, decreasing with the deprotonation of the -NH{sub 3} groups, while for pH > pK{sub a} which for gentamycin is equal to 7.8, the rate constant was unchanged. These observations suggest that when the amino groups are protonated, reductive deamination occurs, but for unprotonated non-reactive amino groups, a radical anion is formed on the glycoside moiety. (Author).

  15. Reactions of linoleic acid peroxyl radicals with phenolic antioxidants: a pulse radiolysis study

    Energy Technology Data Exchange (ETDEWEB)

    Erben-Russ, M.; Bors, W.; Saran, M.

    1987-09-01

    Linoleic acid peroxyl radicals (LOO) can be viewed as model intermediates occurring during lipid peroxidation processes. Formation and reactions of these species were investigated in aqueous alkaline solution using pulse radiolysis combined with kinetic spectroscopy. Irradiation of linoleic acid in N/sub 2/O/O/sub 2/-saturated solutions leads to a mixture of peroxyl radical isomers; reaction of 13-hydroperoxylinoleic acid (13-LOOH) with azide radicals in N/sub 2/O-saturated solution produces 13-LOO radicals specifically. These peroxyl radicals cannot be observed directly, but their reactions with kaempferol and quercetin, acting as radical-scavenging antioxidants, produced strongly absorbing aroxyl radicals (ArO). The same aroxyl radicals were generated by OH and N/sub 3/ with rate constants exceeding 10/sup 9/ dm/sup 3/ mol/sup -1/ s/sup -1/. Applying a reaction scheme that includes competing generation and decay reactions of both LOO and ArO radicals, individual rate constants were derived for LOO reactions with the phenols (> 10/sup 7/ dm/sup 3/ mol/sup -1/ s-./sup 1/), with aroxyl radicals to form covalent adducts (> 10/sup 8/ dm/sup 3/ mol/sup -1/ s/sup -1/), as well as for their bimilecular decay (3.0 x 10/sup 8/ dm/sup 3/ mol/sup -1/ s/sup -1/). These results demonstrate high reactivity of fatty acid peroxyl radicals and flavone antioxidants in aqueous solution.

  16. Pulse radiolysis study of the reactions of catechins with nitrogen dioxide

    Science.gov (United States)

    Gebicki, Jerzy L.; Meisner, Piotr; Stawowska, Katarzyna; Gebicka, Lidia

    2012-12-01

    Nitrogen dioxide (•NO2), one of the oxidizing radicals formed in vivo is suspected to play a role in various pathophysiological processes. The reactions of •NO2 with dietary catechins, the group of flavonoids present in high amounts in green tea and red wine, have been investigated by pulse radiolysis method. The kinetics of the reaction of •NO2 with gallic acid have been also studied for comparison. The spectra of transient intermediates are presented. The rate constants of the reaction of •NO2 with catechin, epigallocatechin, epigallocatechin gallate and gallic acid determined by the competition method with 2,2'-azinobis-(3-ethylbenzthiazoline-6-sulfonate) at pH 7.0 and room temperature have been found to be 0.9, 1.0, 2.3 and 0.5×108 M-1 s-1, respectively. The values for catechins are among the highest reported for the reactions of •NO2 with non-radical compounds.

  17. Pulse radiolysis studies of mangiferin: A C-glycosyl xanthone isolated from Mangifera indica

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, B. [Radiation Chemistry and Chemical Dynamics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Priyadarsini, K.Indira [Radiation Chemistry and Chemical Dynamics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)]. E-mail: kindira@apsara.barc.ernet.in; Sudheerkumar, M. [College of Pharmaceutical Sciences, Kasturba Medical College, Manipal 576119 (India); Unnikrishhnan, M.K. [College of Pharmaceutical Sciences, Kasturba Medical College, Manipal 576119 (India); Mohan, H. [Radiation Chemistry and Chemical Dynamics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

    2006-01-15

    Pulse radiolysis technique has been employed to study the reaction of different oxidizing and reducing radicals with mangiferin. The reaction of {sup {center_dot}}OH radical showed the formation of transient species absorbing in 380-390 and 470-480 nm region. The reaction with specific one-electron oxidants (N{sub 3} {sup {center_dot}}, CCl{sub 3}O{sub 2} {sup {center_dot}}) also showed the formation of similar transient absorption bands and is assigned to phenoxyl radicals. The pK {sub a} values of the transient species have been determined to be 6.3 and 11.9. One-electron oxidation potential of mangiferin at pH 9 has been found to be 0.62 V vs. NHE. The reaction of e{sub aq} {sup -} showed the formation of transient species with {lambda} {sub max} at 340 nm, which is assigned to the ketyl anion radical formed on addition of e{sub aq} {sup -} at carbonyl site. Reactions of one-electron oxidised mangiferin radicals with ascorbic acid have also been studied.

  18. Pulse radiolysis studies of mangiferin: A C- glycosyl xanthone isolated from Mangifera indica

    Science.gov (United States)

    Mishra, B.; Priyadarsini, K. Indira; Sudheerkumar, M.; Unnikrishhnan, M. K.; Mohan, H.

    2006-01-01

    Pulse radiolysis technique has been employed to study the reaction of different oxidizing and reducing radicals with mangiferin. The reaction of rad OH radical showed the formation of transient species absorbing in 380-390 and 470-480 nm region. The reaction with specific one-electron oxidants (N 3rad , CCl 3O 2rad ) also showed the formation of similar transient absorption bands and is assigned to phenoxyl radicals. The p Ka values of the transient species have been determined to be 6.3 and 11.9. One-electron oxidation potential of mangiferin at pH 9 has been found to be 0.62 V vs. NHE. The reaction of e aq- showed the formation of transient species with λmax at 340 nm, which is assigned to the ketyl anion radical formed on addition of e aq- at carbonyl site. Reactions of one-electron oxidised mangiferin radicals with ascorbic acid have also been studied.

  19. Reaction of hydroxyl radical with phenylpropanoid glycoside and its derivatives by pulse radiolysis

    Institute of Scientific and Technical Information of China (English)

    石益民; 王文锋; 康九红; 师彦平; 贾忠建; 王瑛; 苏保宁; 姚思德; 林念芸; 郑荣梁

    1999-01-01

    The reaction of hydroxyl radical with 1 phenylpropanoid glycoside ( PPG), cistanoside C, and its 3 derivatives: 1-O-β-D-2-(p-hydroxyphenyl)-ethanyl-glucose, 6-O-(E)-feruloyl-glucose and 6-O-(E)-p-hydroxy-cinnamoylglucose isolated from folk medicinal herbs was investigated by pulse radiolysis technique respectively. The reaction rate constants were determined by analysis of built-up trace of absorption at λmax of specific transient absorption spectra of PPG and its derivatives upon attacking·OH. All four compounds react with·OH at close to diffusion controlled rate (1.03×109—19.139×109 L·mol-1·s-1), suggesting that they are effective·OH scavengers. The results demonstrated that the numbers of phenolic hydroxyl groups of PPG and its derivatives are directly related to their scavenging activities. By comparing the reaction rates of·OH with 1-O-β-D-2-(p-hydroxyphenyl)-ethanyl-glucose, 6-O-(E)-feruloyl-glueose or 6-O-(E)-p-hydroxy-cinnomoyl-glucose, it is evident that the phenylethyl g

  20. Pulse radiolysis studies on reactions of hydroxyl radicals with selenocystine derivatives.

    Science.gov (United States)

    Mishra, B; Kumbhare, L B; Jain, V K; Priyadarsini, K I

    2008-04-10

    Reactions of hydroxyl radicals (*OH) with selenocystine (SeCys) and two of its analogues, diselenodipropionic acid (SeP) and selenocystamine (SeA), have been studied in aqueous solutions at pHs of 1, 7, and 10 using the pulse radiolysis technique coupled with absorption detection. All of these diselenides react with *OH radicals with rate constants of approximately 10(10) M(-1) s(-1), producing diselenide radical cations ( approximately 1-5 micros after the pulse), with an absorption maximum at 560 nm, by elimination of H(2)O or OH(-) from hydroxyl radical adducts. Assignment of the 560 nm band to the diselenide radical cation was made by comparing the transient spectra with those produced upon reaction of diselenides with specific one-electron oxidants, Cl(2)(*-) (pH 1) and Br(2)(*-) radicals (pHs of 7 and 10). SeP having a carboxylic acid functionality showed quantitative conversion of hydroxyl radical adducts to radical cations. The compounds SeCys and SeA, having an amino functional group, in addition to the radical cations, produced a new transient with lambda(max) at 460 nm, at later time scales ( approximately 20-40 micros after the pulse). The rate and yield of formation of the 460 nm band increased with increasing concentrations of either SeCys or SeA. In analogy with similar studies reported for analogous disulfides, the 460 nm transient absorption band has been assigned to a triselenide radical adduct. The one-electron reduction potentials of the compounds were estimated to be 0.96, 1.3, and 1.6 V versus NHE, respectively, for SeP, SeCys, and SeA at pH 7. From these studies, it has been concluded that the electron-donating carboxylic acid group decreases the reduction potential and facilitates quantitative conversion of hydroxyl radical adducts to radical cations, while the electron-withdrawing NH(3)(+) group not only increases the reduction potential but also leads to fragmentation of the hydroxyl radical adduct to selenyl radicals, which are converted

  1. Radiation-Induced Chemical Reactions in Hydrogel of Hydroxypropyl Cellulose (HPC): A Pulse Radiolysis Study.

    Science.gov (United States)

    Yamashita, Shinichi; Ma, Jun; Marignier, Jean-Louis; Hiroki, Akihiro; Taguchi, Mitsumasa; Mostafavi, Mehran; Katsumura, Yosuke

    2016-12-01

    We performed studies on pulse radiolysis of highly transparent and shape-stable hydrogels of hydroxypropyl cellulose (HPC) that were prepared using a radiation-crosslinking technique. Several fundamental aspects of radiation-induced chemical reactions in the hydrogels were investigated. With radiation doses less than 1 kGy, degradation of the HPC matrix was not observed. The rate constants of the HPC composing the matrix, with two water decomposition radicals [hydroxyl radical ((•)OH) and hydrated electron ([Formula: see text])] in the gels, were determined to be 4.5 × 10(9) and 1.8 × 10(7) M(-1) s(-1), respectively. Direct ionization of HPC in the matrix slightly increased the initial yield of [Formula: see text], but the additionally produced amount of [Formula: see text] disappeared immediately within 200 ps, indicating fast recombination of [Formula: see text] with hole radicals on HPC or on surrounding hydration water molecules. Reactions of [Formula: see text] with nitrous oxide (N2O) and nitromethane (CH3NO2) were also examined. Decay of [Formula: see text] due to scavenging by N2O and CH3NO2 were both slower in hydrogels than in aqueous solutions, showing slower diffusions of the reactants in the gel matrix. The degree of decrease in the decay rate was more effective for N2O than for CH3NO2, revealing lower solubility of N2O in gel than in water. It is known that in viscous solvents, such as ethylene glycol, CH3NO2 exhibits a transient effect, which is a fast reaction over the contact distance of reactants and occurs without diffusions of reactants. However, such an effect was not observed in the hydrogel used in the current study. In addition, the initial yield of [Formula: see text], which is affected by the amount of the scavenged precursor of [Formula: see text], in hydrogel containing N2O was slightly higher than that in water containing N2O, and the same tendency was found for CH3NO2.

  2. Charge transfer from 2-aminopurine radical cation and radical anion to nucleobases: A pulse radiolysis study

    Energy Technology Data Exchange (ETDEWEB)

    Manoj, P. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686 560, Kerala (India); Mohan, H. [Radiation Chemistry and Chemical Dynamics Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Mittal, J.P. [Radiation Chemistry and Chemical Dynamics Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Manoj, V.M. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686 560, Kerala (India); Aravindakumar, C.T. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686 560, Kerala (India)], E-mail: CT-Aravindakumar@rocketmail.com

    2007-01-08

    Pulse radiolysis study has been carried out to investigate the properties of the radical cation of 2-aminopurine (2AP) and the probable charge transfer from the radical cation and radical anion of 2AP to natural nucleobases in aqueous medium. The radical cation of 2AP was produced by the reaction of sulfate radical anion (SO{sub 4}{sup dot-}). The time resolved absorption spectra obtained by the reaction of SO{sub 4}{sup dot-} with 2AP at neutral pH have two distinct maxima at 380 and 470nm and is assigned to the formation of a neutral radical of the form 2AP-N{sup 2}(-H){sup dot} (k{sub 2}=4.7x10{sup 9}dm{sup 3}mol{sup -1}s{sup -1} at pH 7). This neutral radical is formed from the deprotonation reaction of a very short-lived radical cation of 2AP. The transient absorption spectra recorded at pH 10.2 have two distinct maxima at 400 and 480nm and is assigned to the formation of a nitrogen centered radical (2AP-N(9){sup dot}). As the hole transport from 2AP to guanine is a highly probable process, the reaction of SO{sub 4}{sup dot-} is carried out in the presence of guanosine, adenosine and inosine. The spectrum obtained in the presence of guanosine was significantly different from that in the absence and it showed prominent absorption maxima at 380 and 470nm, and a weak broad maximum centered around 625nm which match well with the reported spectrum of a neutral guanine radical (G(-H){sup dot}). The electron transfer reaction from the radical anion of 2AP to thymine (T), cytidine (Cyd) and uridine (Urd) was also investigated at neutral pH. Among the three pyrimidines, only the transient spectrum in the presence of T gave a significant difference from the spectral features of the electron adduct of 2AP, which showed a prominent absorption maximum at 340nm and this spectrum is similar to the electron adduct spectrum of T. The preferential reduction of thymine by 2AP{sup dot-} and the oxidation of guanosine by 2AP{sup dot+} clearly follow the oxidation

  3. Effects of oxidation on copper-binding properties of Aβ1-16 peptide: a pulse radiolysis study.

    Science.gov (United States)

    Ramteke, S N; Ginotra, Y P; Walke, G R; Joshi, B N; Kumbhar, A S; Rapole, S; Kulkarni, P P

    2013-12-01

    The reaction of hydroxyl radicals ((•)OH) with Aβ1-16 peptide was carried out using pulse radiolysis to understand the effect of oxidation of peptide on its copper-binding properties. This reaction produced oxidized, dimeric and trimeric Aβ1-16 peptide species. The formation of these products was established with the help of fluorescence spectroscopy and mass spectrometry. The mass spectral data indicate that the major site of oxidation is at His6, while the site for dimerization is at Tyr10. Diethyl pyrocarbonate-treated Aβ1-16 peptide did not produce any trimeric species upon oxidation with (•)OH. The quantitative chemical modification studies indicated that one of the three histidine residues is covalently modified during pulse radiolysis. The copper-binding studies of the oxidized peptide revealed that it has similar copper-binding properties as the unoxidized peptide. Further, the cytotoxicity studies point out that both oxidized and unoxidized Aβ1-16 peptide are equally efficient in producing free radicals in presence of copper and ascorbate that resulted in comparable cell death.

  4. Kinetics of the F+NO2+M->FNO2+M reaction studied by pulse radiolysis combined with time-resolved IR and UV spectroscopy

    DEFF Research Database (Denmark)

    Pagsberg, Palle Bjørn; Sillesen, A.; Jodkowski, J.T.

    1996-01-01

    The title reaction was initiated by the pulse radiolysis of SF6/NO2 gas mixtures, and the formation of FNO2 was studied by time-resolved infrared spectroscopy employing strong rotational transitions within the nu(1) and nu(4) bands of FNO2. The pressure dependence of the formation kinetics...

  5. Kinetics of the reaction F+NO+M->FNO+M studied by pulse radiolysis combined with time-resolved IR and UV spectroscopy

    DEFF Research Database (Denmark)

    Pagsberg, Palle Bjørn; Sillesen, A.; Jodkowski, J.T.

    1996-01-01

    The title reaction was initiated by pulse radiolysis of SF6/NO gas mixtures, and the formation of FNO was studied by time-resolved IR and UV spectroscopy. At SF6 pressures of 10-320 mbar at 298 K, the formation of FNO was studied by infrared diode laser spectroscopy at 1857.324 cm(-1). Comparative...

  6. One-electron oxidation of mitomycin C and its corresponding peroxyl radicals. A steady-state and pulse radiolysis study

    Science.gov (United States)

    Getoff, Nikola; Solar, Sonja; Quint, Ruth M.

    1997-12-01

    The one-electron oxidation of Mitomycin C (MMC) as well as the formation of the corresponding peroxyl radicals were investigated by both steady-state and pulse radiolysis. The steady-state MMC-radiolysis by OH-attack followed at both absorption bands showed different yields: at 218 nm G i (-MMC) = 3.0 and at 364 nm G i (-MMC) = 3.9, indicating the formation of various not yet identified products, among which ammonia was determined, G(NH 3) = 0.81. By means of pulse radiolysis it was established a total κ (OH + MMC) = (5.8 ± 0.2) × 10 9 dm 3 mol -1 s -1. The transient absorption spectrum from the one-electron oxidized MMC showed absorption maxima at 295 nm ( ɛ = 9950 dm 3 mol -1 cm t-1 ), 410 nm ( ɛ = 1450 dm 3 mol -1 cm -1) and 505 nm ( ɛ = 5420 dm 3 mol -1 cm -1). At 280-320 and 505 nm and above they exhibit in the first 150 μs a first order decay, κ1 = (0.85 ± 0.1) × 10 3 s -1, and followed upto ms time range, by a second order decay, 2 κ = (1.3 ± 0.3) × 10 8 dm 3 mol -1 s -1. Around 410 nm the kinetics are rather mixed and could not be resolved. The steady-state MMC-radiolysis in the presence of oxygen featured a proportionality towards the absorbed dose for both MMC-absorption bands, resulting in a G i (-MMC) = 1.5. Among several products ammonia-yield was determined G(NH 3) = 0.52. The formation of MMC-peroxyl radicals was studied by pulse radiolysis, likewise in neutral aqueous solution, but saturated with a gas mixture of 80% N 2O and 20% O 2. The maxima of the observed transient spectrum are slightly shifted compared to that of the one-electron oxidized MMC-species, namely: 290 nm ( ɛ = 10100 dm 3 mol -1 cm -1), 410 nm ( ɛ = 2900 dm 3 mol -1 cm -1) and 520 nm ( ɛ = 5500 dm 3 mol -1 cm -1). The O 2-addition to the MMC-one-electron oxidized transients was found to be at 290 to 410 nm gk(MMC·OH + O 2) = 5 × 10 7 dm 3 mol -1 s -1, around 480 nm κ = 1.6 × 10 8 dm 3 mol -1 s -1 and at 510 nm and above, κ = 3 × 10 8 dm 3 mol -1 s -1. The

  7. Pulse radiolysis studies of short-lived species in solid amino acids as precursors of radicals and detected by ESR

    Science.gov (United States)

    Zagórski, Z. P.; Gładysz, Katarzyna

    1995-06-01

    The aim of the study was to bring closer solid state radiation chemistry and ESR spectroscopy by looking for precursors of free radicals which give ESR signals. It has been performed using time-resolved spectrophotometry (pulse radiolysis of the solid state) and diffuse reflection spectrophotometry. Alanine has been especially considered as the most investigated amino acid, important for radiation dosimetry. Absorption of the transient (Λ maximum at 460 nm) is identified as the species during deamination. The stable absorption spectrum with the Λ maximum at 345 nm is due to the same radical as the one detected by ESR. Other amino acids: valine, threonine, glutamine and arginine show similar behaviour: microsecond spectrum of the intermediate appears always at longer wavelenghts. The transient spectrum changes into stable absorption in UV of a lower wavelenght. Along with the optical spectrum, the ESR spectrum appears, of similar stability. Also, other features indicate that the same radical is responsible for both the electronic and ESR spectrum. Some amino acids, like methionine give intensive transient absorption in the microsecond range but no ESR signal, after completion of consecutive fast reactions. In that case any optical absorption is due to the stable product of radiolysis, i.e. compounds with paired electrons only.

  8. Pulse radiolysis of tetrazolium violet in aqueous and aqueous-alcoholic solutions under oxidative and reductive conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, A. [Institute of Isotopes, Hungarian Academy of Sciences, P.O. Box 77, H-1525 Budapest (Hungary)], E-mail: akovacs@iki.kfki.hu; Wojnarovits, L.; Palfi, T. [Institute of Isotopes, Hungarian Academy of Sciences, P.O. Box 77, H-1525 Budapest (Hungary); Emi-Reynolds, G. [Radiation Protection Institute, Ghana Atomic Energy Commission, P.O. Box LG 80, Legon-Accra (Ghana); Fletcher, J. [Department of Physics, University of Cape Coast, Cape Coast (Ghana)

    2008-09-15

    The radiolytic reduction of colourless tetrazolium salts to coloured formazans in liquid and solid state is suggested for dosimetry purposes. In order to clarify the reaction mechanism, a pulse radiolysis study was conducted in aqueous and aqueous-alcoholic solutions under oxidative and reductive conditions. Under reducing conditions, fast formation of the electron adduct tetrazolinyl radical was observed: coloured formazan final product formed during the decay of electron adduct. Both the decay of the tetrazolinyl radical and the formation of the formazan were found to be second order. The spectra of the formazan were similar in neutral and alkaline solutions, but with higher absorbance in the latter solutions due to the higher molar absorption coefficient. Under oxidative conditions formazan did not form; hydroxylated products through OH-adducts were observed in the pH range studied.

  9. Pulse radiolysis of tetrazolium violet in aqueous and aqueous-alcoholic solutions under oxidative and reductive conditions

    Science.gov (United States)

    Kovács, A.; Wojnárovits, L.; Pálfi, T.; Emi-Reynolds, G.; Fletcher, J.

    2008-09-01

    The radiolytic reduction of colourless tetrazolium salts to coloured formazans in liquid and solid state is suggested for dosimetry purposes. In order to clarify the reaction mechanism, a pulse radiolysis study was conducted in aqueous and aqueous-alcoholic solutions under oxidative and reductive conditions. Under reducing conditions, fast formation of the electron adduct tetrazolinyl radical was observed: coloured formazan final product formed during the decay of electron adduct. Both the decay of the tetrazolinyl radical and the formation of the formazan were found to be second order. The spectra of the formazan were similar in neutral and alkaline solutions, but with higher absorbance in the latter solutions due to the higher molar absorption coefficient. Under oxidative conditions formazan did not form; hydroxylated products through OH-adducts were observed in the pH range studied.

  10. Pulse radiolysis of aqueous solutions of ethyl acrylate and hydroxy ethyl acrylate

    Science.gov (United States)

    Safrany, A.; Biro, A.; Wojnarovits, L.

    1993-10-01

    Ethyl- and hydroxy ethyl acrylate show high reactivities with hydrated electron and hydroxyl radical intermediates of water radiolysis. The electron adduct reversibly protonate with pK values of 5.7 and 7.3. The adducts may take part in irreversible protonation at the β carbon atom forming α-carboxyl alkyl radicals. Same type of radical forms in reaction of acrylates with OH: at low concentration the adduct mainly disappear in self termination reactions. Above 5 mmol dm -1 the signals showed the startup of oligomerization.

  11. Pulse radiolysis studies of liquid heavy water at temperatures up to 250 degrees C

    Energy Technology Data Exchange (ETDEWEB)

    Stuart, C.R.; Ouellette, D.C.; Elliot, A.J

    2002-09-01

    This report documents the rate constants and associated activation energies for the reactions of the primary radical species, e{sub aq}{sup -}, {center_dot}OD and {center_dot}D, which are formed during the radiolysis of heavy water within the temperature range 20 to 250 {sup o}C. These heavy-water data have been compared with the corresponding information for light water. These kinetic data form part of the database that is required to model the aqueous radiation chemistry that occurs within the core of the heavy water cooled and moderated CANDU reactor. (author)

  12. Competition between reactive sites during the pulse radiolysis of styrene in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    McAskill, N.A. (Commonwealth Scientific and Industrial Research Organization, Lucas Heights (Australia). Div. of Energy Chemistry); Sangster, D.F. (Commonwealth Scientific and Industrial Research Organization, Lucas Heights (Australia). Div. of Chemical Physics)

    1984-01-01

    The optical absorptions of the transient species formed by the reactions of the primary radiolysis products of water (e/sup -/, H, and OH) with styrene were measured. There are large differences between the various literature estimates for these reaction pathways. Most of the e/sup -/ and H and about 50% of the OH react with the unsaturated vinyl side chain to give the ..cap alpha..-methylbenzyl and hydroxy-substituted methylbenzyl radical respectively. The remaining OH reacts with the aromatic ring to give hydroxy(vinyl)cyclohexadienyl radicals.

  13. Ultra-fast pulse radiolysis system combined with a laser photocathode RF gun and a femtosecond laser

    CERN Document Server

    Muroya, Y; Watanabe, T; Wu, G; Kobayashi, T; Yoshii, K; Ueda, T; Uesaka, M; Katsumura, Y

    2002-01-01

    In order to study the early events in radiation physics and chemistry, two kinds of new pulse radiolysis systems with higher time resolution based on pump-and-probe method have been developed at the Nuclear Engineering Research Laboratory, the University of Tokyo. The first one, a few picosecond (2 ps at FWHM) electron beam (pump) from an 18 MeV S-band Linac using a laser photocathode RF gun (BNL/KEK/SHI type: GUN IV) was operated with a femtosecond laser pulse (100 fs at FWHM), which also acted as the analyzing light (probe). The synchronization precision between the pump and the probe was 1.7 ps (rms). In a 1.0 cm sample cell, a time resolution of 12 ps was achieved. The second one, a picosecond (4 ps at FWHM) electron pulse from a 35 MeV S-band Linac employing a conventional thermionic gun with a sub-harmonic buncher, was synchronized with the femtosecond laser pulse, with a synchronization jitter of 2.8 ps (rms). A time resolution of 22 ps was obtained with 2 cm cell. This makes it possible to do the puls...

  14. 早稻田大学皮秒脉冲辐解装置%Development of picosecond pulse radiolysis system at Waseda University

    Institute of Scientific and Technical Information of China (English)

    T Kuribayashi; K Ushida; S Kashiwagi; R Kuroda; H Hirama; M Kawaguchi; Y Hama; M Washio

    2005-01-01

    A compact pulse radiolysis apparatus using a BNL-type s-band photocathode RF gun is now under development at Waseda University. The laser pulse is used for excitation of the photocathode and for generation of white light, which is used for analyzing light in the pulse radiolysis.The system design is shown in Fig. 1. For absorption spectroscopy with wide wavelength region, the white-light continuum was used as analyzing light. The white light continuum was generated by focusing the high intense IR laser into the water cell. The available wavelength was 400-950 nm. Typical data obtained is shown in Fig.2 by using the system. We have performed a deconvolution technique to know the time resolution of our system. For this purpose, we have assumed the shapes of the electron pulse and the laser pulse as Gaussian distributions. Furthermore, the difference of velocity in a sample cell between the electron pulse and the laser pulse due to the refractive index of a sample was also taken into consideration and assuming that the hydrated electrons are formed as a step function and the response function is Gaussian.Thus, time resolution of the system was estimated by deconvolution of the experimental data.We have achieved a time resolution of about 26ps by measuring time profile of hydrated electrons in H2O.

  15. Favism inducing agents: a pulse radiolysis study of isouramil and convicine. Progress report, December 1, 1979 - November 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Chevion, M.; Ilan, Y.A.

    1980-01-01

    Isouramil and covicine, substances implicated in precipitating favic crises in glucose-6-phosphate dehydrogenase deficient individuals, have been studied in N/sub 2/O-saturated aqueous solutions by pulse radiolysis, and the kinetics of the reactions of both substances with OH radicals were determined. The products of these reactions are addition intermediates absorbing above 330 nm. The decay of the intermediate(s) formed in the isouramil reaction is a biphasic one, while the decay of the corresponding intermediate for the convicine reaction is characterized by a single constant. By analogy to uracil, it is suggested that the OH radical is added to the double bond at either positions 5 or 6 of the pyrimidine ring forming two different intermediates. Each of these intermediates loses a molecule of water indicated by the observed biphasic decay reaction. For convicine on the other hand, position 5 is blocked by the O-gucosidic bond and the addition of the OH radical could take place only at position 6. Thus, a single intermediate is formed and its decay is a single-phase one. It has been shown that although free radicals could not be detected in the course of the reactions between isouramil and oxygen or with cellular components by electron paramagnetic resonance, isouramil can participate in a uni-electron transfer reacton and can form relatively stable intermediates. Thus, it is speculated that in the red blood cells isouramil could give rise to deleterious free radicals.

  16. Kinetics and mechanism of superoxide radical reactions with some biologically important compounds in aqueous solutions. Pulse radiolysis

    Science.gov (United States)

    Revina, A. A.; Amiragova, M. I.; Volod'ko, V. V.; Vannikov, A. V.

    Microsecond pulse radiolysis of oxygenated aqueous solutions containing 0.02 mol dm -3 sodium formate and 2 mmol dm -3 phosphate buffer at pH 7 was used to generate superoxide anion radicals. The influence of some biologically important compounds upon the rate of O ⨪2 decay was monitored spectrophotometrically in the range of 245-300 nm. Hematoporphyrin (HP), hemin C (HC), catalase (Cat), cobalt sulfophthalocyanine (CoTSPc) were studied. Among the investigated compounds only Cat was found to show a high catalytic efficiency towards the self-decay of O ⨪2. A red shift of O ⨪2 absorption band and slowing down of its decay were observed to take place by adding HP or CoTSPc to the solutions containing formate ions in excess. This effect is associated with the formation of a transient superoxo-complex. An appearance of an intermediate species with absorption maxima at 350 nm and half-life of about 2s was observed to accompany the superoxo-complex of CoTSPc decay. In the aerated solution of HP the intensity of absorbance at 260 nm was found to be independent of the presence of formate ions.

  17. Superoxide radical anion scavenging and dismutation by some Cu2+ and Mn2+ complexes: A pulse radiolysis study

    Science.gov (United States)

    Joshi, Ravi

    2017-10-01

    Copper (Cu) and manganese (Mn) ions are catalytic centers, in complexed form, in scavenging and dismutation process of superoxide radicals anion (O2.-) by superoxide dismutase enzyme. In the present work, fast reaction kinetics and mechanism of scavenging and dismutation of O2.- by Cu2+, Mn2+ and their complexes formed with some natural ligands have been studied using pulse radiolysis technique. Catechol, gentisic acid, tetrahydroxyquinone, tyrosine, tryptophan, embelin and bilirubin have been used as low molecular weight natural ligands for Cu2+ and Mn2+ to understand superoxide radical scavenging and dismutation reactions. These complexes have been found to be efficient scavengers of O2.- (k 107-109 M-1 s-1). The effects of nature of metal ion and ligand, and stoichiometry of complex on scavenging reaction rate constants are reported. Higher scavenging rate constants have been observed with complexes of: (1) Cu2+ as compared to Mn2+, and (2) at [ligand]/[metal] ratio of one as compared to two. A clear evidence of O2.- dismutation by free metal ions and some of the complexes has been observed. The study suggests that complexes of Cu2+ and Mn2+ with small natural ligands can also act as SOD mimics.

  18. Pulse Radiolysis Studies of Temperature Dependent Electron Transfers among Redox Centers in ba(3)-Cytochrome c Oxidase from Thermus thermophilus

    DEFF Research Database (Denmark)

    Farver, Ole; Wherland, Scot; Antholine, William E

    2010-01-01

    in cytochrome ba(3) had no effect on the rate of this reaction whereas the II-Met160Leu Cu(A)-mutation was slower by an amount corresponding to a decreased driving force of ∼0.06 eV. The structures support the presence of a common, electron-conducting "wire" between Cu(A) and heme-a(b). The transfer......-a(b)(o) → Cu(A)(o) + heme-a(b)(r) in three structurally characterized enzymes: A-type aa(3) from Paracoccus denitrificans (PDB code 3HB3 ) and bovine heart tissue (PDB code 2ZXW ), and the B-type ba(3) from T. thermophilus (PDB codes 1EHK and 1XME ). k,T data sets were obtained with the use of pulse radiolysis...... of an electron from the low-spin heme to the high-spin heme, i.e., heme-a(b)(r) + heme-a(3)(o) → heme-a(b)(o) + heme-a(3)(r), was not observed with the A-type enzymes in our experiments but was observed with the Thermus ba(3); its Marcus parameters are λ = 1.5 eV, H(ab) = 26.6 × 10(-5) eV (2.14 cm(-1)), and β...

  19. Guanosine radical reactivity explored by pulse radiolysis coupled with transient electrochemistry.

    Science.gov (United States)

    Latus, A; Alam, M S; Mostafavi, M; Marignier, J-L; Maisonhaute, E

    2015-06-04

    We follow the reactivity of a guanosine radical created by a radiolytic electron pulse both by spectroscopic and electrochemical methods. This original approach allows us to demonstrate that there is a competition between oxidation and reduction of these intermediates, an important result to further analyse the degradation or repair pathways of DNA bases.

  20. Pulse radiolysis studies of electron migration in DNA from DNA base-radical anions to nitroacridine intercalators in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.F.; Patel, K.B. (Mount Vernon Hospital, Northwood (United Kingdom). Gray Lab.); Wilson, W.R. (Univ. of Auckland School of Medicine (New Zealand))

    1991-12-07

    The reactions of the aquated electron (e{sub aq}{sup -}) with intercalators of high reduction potential (nitracrine and related basic nitroacridines) has been investigated by pulse radiolysis in the presence of DNA in aqueous solution. Under conditions where the majority of the e{sub aq}{sup -} species react initially with DNA bases (high DNA:drug ratios) a slower subsequent electron transfer to the intercalator was observed. The rate of this intra-complex transfer, expressed as DNA base pairs traversed per second, was in the range (1.2-3.1) x 10{sup 5} base pairs s{sup -1} and increased in order of the one-electron reduction potentials of the DNA-bound intercalators. No transfer was seen to the much less electron affinic des-nitro analogue of the nitroacridines. Only a small proportion of the initial DNA base radicals ({<=}50%) underwent this intra-complex electron transfer. Even for the most efficient electron trap, nitracrine, the apparent mean electron migration distance was only three base pairs. A slow secondary reduction of nitroacridines ((0.08-5.0) x 10{sup 4} base pairs s{sup -1}) was also observed with a proportion of the essentially immobile {sup .}OH-induced DNA radicals. This secondary reaction may well serve as a measure of the mobility of the DNa-bound intercalators. This study therefore implies a lack of extensive migration of DNA-associated electrons in aqueous solution, although it does not exclude the possibility that more mobile electrons produced by direct ionization of DNA might migrate over large distances. (author).

  1. Pulse radiolysis studies on the release of cytotoxins from electron affinic anticancer prodrugs following their one-electron reduction

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.F.; Ware, D.C.; Denny, W.A.; Lee, H.; Tercel, M.; Wilson, W.R. [Auckland Univ. (New Zealand)

    1996-12-31

    New approaches to killing chemoresistant and radioresistant hypoxic cells of solid tumours include the selective release of potent cytotoxins from relatively non-toxic prodrugs through reductive metabolism and/or radiolytic reduction. Central to these studies, is an understanding of the mechanism of cytotoxin release and the basis of hypoxia-selectivity, since such information can be used to design compounds of high potency against solid tumours. Pulse radiolysis studies can offer unique insights into these underlying mechanisms in aqueous solution through the determination of thermodynamic one-electron reduction potentials of the prodrugs, rate constants for the formation and spectral charaterization of one-electron reduced prodrugs, the kinetics release of the cytotoxins from one-electron reduced prodrugs and the influence of molecular oxygen on the obligate radical intermediates. A series of different triggers, which are found to vary greatly in the rate constant for release of the effectors upon one-electron reduction of the prodrugs, will be discussed. Release of effector from a prodrug does not solely depend upon the type of trigger but can also be dependent on the type of linker and released effector. For example, whereas fast quantitative release of the mustard effector mechlorethamine is seen from the quaternary nitroimidazole upon one electron reduction, release of N-[2-(dimethylamino)ethyl] acridine-4-carboxamide (DACA), requires a higher level of reduction of the same trigger. Release of cytotoxic ligands from metal complexes requires that the metal centre is reduced. When the metal centre is lower than DACA bound as a ligand, reduction is seen to occur solely on the ligand without release from the metal centre. 1 ref., 1 fig.

  2. Dynamics of radical cations of poly(4-hydroxystyrene) in the presence and absence of triphenylsulfonium triflate as determined by pulse radiolysis of its highly concentrated solution

    Science.gov (United States)

    Okamoto, Kazumasa; Ishida, Takuya; Yamamoto, Hiroki; Kozawa, Takahiro; Fujiyoshi, Ryoko; Umegaki, Kikuo

    2016-07-01

    Pulse radiolysis of highly concentrated poly(4-hydroxystyrene) (PHS) solutions in cyclohexanone and p-dioxane was performed both with and without an onium-type photoacid generator (PAG). With increasing PHS concentration, the rate constant of deprotonation of PHS radical cations was found to decrease. In the presence of PAG, the yield of the multimer radical cation of PHS was shown to decrease. We found that pairing between the anions produced by the attachment of dissociative electrons of PAGs and the monomer PHS radical cations restrict local molecular motions, leading to the formation of the multimer PHS radical cations.

  3. Radiation Chemistry of Xenon Trioxide, Xenate and Perxenate and Photochemistry of Perxenate - A Pulse Radiolysis and Laser Flash-Photolysis Study

    DEFF Research Database (Denmark)

    Kläning, U. K.; Sehested, Knud; Wolff, T.

    1982-01-01

    Unstable species containing xenon in the formal oxidation states five, XeV, and seven, XeVII, were observed by pulse radiolysis of aqueous solutions of xenon trioxide, XeO3, at pH 8–9 and of xenate, HXeO–4, at pH 11–13. XeVII and species containing xenon in the formal oxidation state nine, Xe......IX, were observed in pulse radiolysis and flash photolysis of aqueous solutions of perxenate, HXeO3–6, at pH 11–13. The formulae HXeO3 and H3XeO2–7 are assumed for XeV and XeIX, whereas the observations suggest that XeVII corresponds to three different species for which the formulae HXeO4, HXeO2–5 and H3XeO......2–6 are assumed. HXeO3 and H3XeO2–6 are formed in reactions of the hydrated electron with XeO3 and HXeO3–6, respectively. HXeO4 and H3XeO2–7 are formed in reactions of the hydroxyl radical with XeO3 and HXeO3–6 in which the hydroxyl radical adds to a ligand oxygen atom to form peroxy compounds. HXe...

  4. Pulse radiolysis, flash photolysis, and shock wave study of the recombination H + benzyl yields toluene at 300 and 1,300-1,650 K

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, L.; Hippler, H.; Pagsberg, P.; Reihs, C.; Troe, J. (Institut fuer Physikalische Chemie der Universitaet Goettingen (West Germany) Riso National Laboratory (Denmark))

    1990-06-28

    Pulse radiolysis, discharge flash photolysis, and laser flash photolysis have been employed to study the recombination reaction H + benzyl {yields} toluene at room temperature. Both H atoms and benzyl radicals were monitored. The same reaction was studied directly in shock waves between 1,300 and 1.650 K. The value of the high-pressure recombination rate constant of (2.5 {plus minus} 0.8) {times} 10{sup 14} cm{sup 3} mol{sup {minus}1} s{sup {minus}1} was found to be independent of the temperature between 300 and 1,650 K. It is argued that high-pressure rate constants for other recombination reactions should also have very small temperature coefficients over wide temperature ranges. Room temperature rate constants for addition of H atoms to toluene, cycloheptatriene, p-xylene, benzene, phenyl, and p-methylbenzyl are also reported.

  5. Kinetics of the addition reaction of methyl radicals with nitric oxide studied by pulse radiolysis combined with infrared diode laser spectroscopy

    DEFF Research Database (Denmark)

    Jodkowski, J.T.; Ratajczak, E.; Sillesen, A.

    1993-01-01

    The reaction CH3 + NO (+ M) --> CH3NO ( + M) was initiated by pulse radiolysis of acetone/nitric oxide mixtures and the kinetics of methyl radicals was studied by time-resolved infrared absorption spectroscopy. The rate constant was found to be strongly pressure dependent in the range of p (M) = 6.......5-150 mbar at 298 K with M = acetone as the third body. The experimental results are represented in terms of a fall-off curve centered at 37 mbar with limiting high- and low-pressure rate constants of k(rec,infinity) = (6.6 +/- 0.9) x 10(9) x (T/300)0.6 M-1 s-1 and k(rec,0)/[M] = (4.4 +/- 0.4) x 10(12) x (T...

  6. A pulse radiolysis investigation of the reactions of tributyl phosphate with the radical products of aqueous nitric acid irradiation.

    Science.gov (United States)

    Mincher, Bruce J; Mezyk, Stephen P; Martin, Leigh R

    2008-07-17

    Tributyl phosphate (TBP) is the most common organic compound used in liquid-liquid separations for the recovery of uranium, neptunium, and plutonium from acidic nuclear fuel dissolutions. The goal of these processes is to extract the actinides while leaving fission products in the acidic, aqueous phase. However, the radiolytic degradation of TBP has been shown to reduce separation factors of the actinides from fission products and to impede the back-extraction of the actinides during stripping. As most previous investigations of the radiation chemistry of TBP have focused on steady state radiolysis and stable product identification, with dibutylphosphoric acid (HDBP) invariably being the major product, here we have determined room temperature rate constants for the reactions of TBP and HDBP with the hydroxyl radical [(5.00 +/- 0.05) x 10(9), (4.40 +/- 0.13) x 10(9) M(-1) s(-1)], hydrogen atom [(1.8 +/-0.2) x 10(8), (1.1 +/- 0.1) x 10(8) M(-1) s(-1)], nitrate radical [(4.3 +/- 0.7) x 10(6), (2.9 +/- 0.2) x 10(6) M(-1) s(-1)], and nitrite radical (<2 x 10 (5), <2 x 10(5) M(-1) s(-1)), respectively. These data are used to discuss the mechanism of TBP radical-induced degradation.

  7. Quatenary structure of methemoglobin II. Pulse radiolysis study of the binding of oxygen to the valence-hybrid. Progress report, December 1, 1978-November 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Chevion, M; Ilan, Y A; Samuni, A; Navok, T; Czapski, G

    1979-01-01

    The pulse-radiolysis of solutions of adult human methemoglobin was used in order to reduce a single heme-iron within the protein tetramers. The valence-hybrids thus formed were reacted with oxygen. Kinetics of the reactions were studied. The effects of pH and inositol-hexaphosphate were examined. The kinetics of the ligation of oxygen to stripped valence-hybrids showed a single-phase behavior at the pH range 6.5 to 9. As the pH was lowered below 6.5 a second, slower phase became apparent. In the presence of IHP, above pH 8, the kinetics of oxygem binding was of a single phase. As the pH was lowered a transition to a second, slower phase was noticed. Below pH 7 the slower phase was the only detectable one. The analysis of the relative contribution of the faster phase to the total reaction as a function of the pH showed a typical transition curve characterized by a pK = 7.5 and a Hill parameter n =2.9. On the basis it is concluded that human adult stripped methemoglobin resides in an R quarternary structure while the presence of IHP stabilizes the T structure at pH below 7.5.

  8. Pulse radiolysis study of reactions of alkyl and alkylperoxy radicals originating from methyl tert-butyl ether in the gas phase

    DEFF Research Database (Denmark)

    Langer, S.; Ljungström, E.; Ellermann, T.;

    1995-01-01

    UV spectra and kinetics for the reactions of alkyl and alkylperoxy radicals from methyl tert-butyl ether (MTBE) were studied in 1 atm of SF6 by the pulse radiolysis-UV absorption technique. UV spectra for the radical mixtures were quantified from 215 to 340 nm. At 240 nm, sigma(R) = (2.6 +/- 0.4) X...... 10(-18) cm(2) molecule(-1) and sigma(RO2) = (4.1 +/- 0.6) X 10(-18) cm(2) molecule(-1) (base e). The rate constant for the self-reaction of the alkyl radicals is (2.5 +/- 1.1) X 10(-11) cm(3) molecule(-1) s(-1). The rate constants for reaction of the alkyl radicals with molecular oxygen...... and the alkylperoxy radicals with NO and NO2 are (9.1 +/- 1.5) X 10(-13), (4.3 +/- 1.6) X 10(-12) and (1.2 +/- 0.3) X 10(-11) cm(3) molecule(-1) s(-1), respectively. The rate constants given above refer to reaction at the tert-butyl side of the molecule....

  9. The Reaction Mechanism and Rate Constants in the Radiolysis of Fe2+-Cu2+ Solutions

    DEFF Research Database (Denmark)

    Bjergbakke, Erling; Sehested, Knud; Rasmussen, O. Lang

    1976-01-01

    Pulse radiolysis and gamma radiolysis have been used to study the reaction mechanism in the radiolysis of aqueous solutions of Fe2+ and Cu2+. A reaction scheme has been developed and confirmed by computation of the corresponding complete set of differential equations. The rate constants for some...

  10. Pulse radiolysis studies on the formation and transformation of the one-electron reduced intermediate of Kalafungin and an analogue solution

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, R.F.; Packer, J.E. [Auckland Univ. (New Zealand). Dept. of Chemistry; Brimble, A.; Nairn, M.R. [Sydney Univ., Sydney, NSW (Australia). Dept. of Chemistry

    1996-12-31

    Kalafungin 1 is a member of the pyranonaphthoquinone family of antibiotics which are produced various species of Streptomyces and have in common the benzoisochromanquinone skeleton. Apart from their already documented activity against Gram-positive bacteria, fungi, and mycoplasmas, it has been suggested that in vivo reduction causes a transformation to an active hydroquinone form which functions as a bis-alkylating agent.{sup 2} Moore{sup 2},{sup 3} has suggested that these pyranonaphthoquinones may exhibit antitumour activity since the proposed mechanism of action resembles that of the anticancer agent mitomycin C 3.{sup 2}. Rapid one-electron reduction of kalafungin 1 and a closely related analogue 2 has been carried out using The University of Auckland`s pulse radiolysis facility. Pulsed electrons (4 Gy in 200 ns from a 4 MeV linear accelerator) were delivered to de-aerated aqueous solutions (10 mmol.L{sup -1} phosphate, pH 7.0) containing 0.1 mol.L{sup -1} sodium formate and 50 - 200 {mu}mol.L{sup -1} kalafungin 1 or lactol 2. Radical formation and transformations were followed by time-resolved uv/visible spectrophotometry. The transformations observed are independent of both the concentration of the parent compound and radiation doses (i.e. semiquinone concentration). The accompanying changes in absorption are consistent with the radical centre of the semiquinone species undergoing intramolecular rearrangement onto the fused non-aromatic ring structure of the compound. Possible ring opening mechanisms and the position of radical relocalisation will be discussed, as well as the involvement of radical transformation and redox chemistry in the biological activity of kalafungin1. Extended abstract. 4 refs., ills.

  11. Pulse radiolysis study on the mechanisms of reactions of CCl3OO· radical with quercetin, rutin and epigallocatechin gallate

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The mechanisms of reactions between CCl3OO· radical and quercetin, rutin and epigallocatechin gallate (EGCG) have been studied using pulse radiolytic technique. It is suggested that the electron transfer reaction is the main reaction between CCl3OO· radical and rutin, EGCG, but there are two main pathways for the reaction of CCl3OO· radical with quercetin, one is the electron transfer reaction, the other is addition reaction. The reaction rate constants were determined. It is proved that quercetin and rutin are better CCl3OO· radical scavengers than EGCG.

  12. Chemical, pulse radiolysis and density functional studies of a new, labile 5,6-indolequinone and its semiquinone.

    Science.gov (United States)

    Pezzella, Alessandro; Crescenzi, Orlando; Natangelo, Anna; Panzella, Lucia; Napolitano, Alessandra; Navaratnam, Suppiah; Edge, Ruth; Land, Edward J; Barone, Vincenzo; d'Ischia, Marco

    2007-03-02

    The chemical and spectroscopic characterization of 5,6-indolequinones and their semiquinones, key transient intermediates in the oxidative conversion of 5,6-dihydroxyindoles to eumelanin biopolymers, is a most challenging task. In the present paper, we report the characterization of a novel, relatively long-lived 5,6-indolequinone along with its semiquinone using an integrated chemical, pulse radiolytic, and computational approach. The quinone was obtained by oxidation of 5,6-dihydroxy-3-iodoindole (1a) with o-chloranil in cold ethyl acetate or aqueous buffer: it displayed electronic absorption bands around 400 and 600 nm, was reduced to 1a with Na2S2O4, and reacted with o-phenylenediamine to give small amounts of 3-iodo-1H-pyrrolo[2,3-b]phenazine (2). The semiquinone exhibited absorption maxima at 380 nm (sh) and 520 nm and was detected as the initial species produced by pulse radiolytic oxidation of 1a at pH 7.0. DFT investigations indicated the 6-phenoxyl radical and the N-protonated radical anion as the most stable tautomers for the neutral and anion forms of the semiquinone, respectively. Calculated absorption spectra in water gave bands at 350 (sh) and 500 nm for the neutral form and at 310 and 360 (sh) nm for the anion. Disproportionation of the semiquinone with fast second-order kinetics (2k = 1.1 x 1010 M-1 s-1) gave a chromophore with absorption bands resembling those of chemically generated 1a quinone. Computational analysis predicted 1a quinone to exist in vacuo as the quinone-methide tautomer, displaying low energy transitions at 380 and 710 nm, and in water as the o-quinone, with calculated absorption bands around 400 and 820 nm. A strong participation of a p orbital on the iodine atom in the 360-380 nm electronic transitions of the o-quinone and quinone-methide was highlighted. The satisfactory agreement between computational and experimental electronic absorption data would suggest partitioning of 1a quinone between the o-quinone and quinone

  13. Studies on laser flash photolysis and pulse radiolysis of quinoline and some of its derivatives%喹啉及其衍生物的脉冲辐解和激光光解研究

    Institute of Scientific and Technical Information of China (English)

    ZHU Dazhang; WANG Shilong; SUN Xiaoyu; LI Wenzhe; ZENG Kailing; NI Yaming; WANG Wenfeng; YAO Side

    2005-01-01

    Quinoline and some of its derivatives were reported to be carcinogenic, toxic and mutagenic[1-3]. The widespread use of quinoline and its derivatives entails that these compounds are distributed in the environment, polluting soil and water together with many other environmental chemicals.Time-resolved laser flash photolysis and pulse radiolysis have been used to study the reaction of quinoline (Q), 2, 6-dimethyl-quinoline (DMQ) and isoquinoline (IQ) with hydrated electrons, hydroxyl radicals and hydrogen radicals. Transient absorption spectra were obtained and reaction rate constants to the reactions were determined, as showed in Table 1. Rossible mechanisms of the reactions were suggested.In addition, oxidization reactions of SO4·-, Br2·- and N3·- with isoquinoline, quinoline and its derivatives were studied. It showed that SO4- could oxidize quinoline, 2, 6-dimethylquinoline and isoquinoline; Br2·-could oxidize isoquinoline to its cation radicals, but it could not oxidize quinoline or 2, 6-diemethylquinoline; N3·- could oxidize none of them.With a better understandings on photolysis and radiolysis of isoquinoline, quinoline and its derivates, the study is of help for degradation of the chemicals and for environment protection.

  14. ONE-ELECTRON OXIDATION OF PHENANTHRENEQUINONE STUDIED BY PULSE RADIOLYSIS%用脉冲辐解技术研究菲醌的单电子氧化

    Institute of Scientific and Technical Information of China (English)

    包华影

    2003-01-01

    采用脉冲辐解技术,以羟基自由基和硫酸根自由基作为氧化剂,研究了9,10-菲醌(PhQ)在水溶液中的单电子氧化行为,获取了瞬态产物的吸收光谱和有关动力学数据.在中性pH条件下,PhQ与羟基自由基以(1.5±0.2)(1010 dm3·mol-1·s-1的速率反应,生成一个初级瞬态产物.该瞬态产物的吸收光谱呈现出位于370nm的吸收峰和在较长波长下的一个宽吸收带.进一步实验观察到,随着短波长区初级吸收的衰减,可见光区的吸收同步增加,在400nm处形成最大吸收峰,并产生以500nm为中心的宽吸收带,表明次级瞬态产物的形成.PH9.9条件下得到的结果与中性pH的一致.降低pH至2-4,尽管初始瞬态吸收谱也呈现出位于370nm的最大吸收峰,但伴随着初始吸收的衰减,没有观察到可见区域吸收的增加.在中性pH条件下,硫酸根自由基与PhQ反应的速率常数测定为(4.0±0.6)(109dm3·mol-1·s-1,生成的瞬态吸收谱与氢氧自由基反应得到的次级吸收谱一致,呈现以400nm和500nm为中心的两个吸收带.基于光谱的相似性和动力学分析,以及羟基自由基和硫酸根自由基的特性,本工作推断反应机理如下:PhQ羟基自由基反应首先生成OH加成产物,OH加成产物脱水生成阳离子自由基;阳离子自由基亦可通过硫酸根自由基的氧化直接产生.%The one-electron oxidation of phenanthrenequinone (PhQ) in aqueous solutions was investigated by pulse radiolysis using hydroxyl radical and sulphate radical as oxidants. Spectral and kinetic properties of the transients formed due to the reaction of PhQ with the oxidants were obtained. The reaction of hydroxyl radical with PhQ results in an initial species with an absorption spectrum centered at 370nm and a weak broad band in the long wavelength regions at neutral pH. The bimolecular rate constant for the formation of initial species was determined to be (1.5±0.2)(1010dm3·mol-1·s-1. The absorption in the

  15. Radiolysis Process Model

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Edgar C.; Wittman, Richard S.; Skomurski, Frances N.; Cantrell, Kirk J.; McNamara, Bruce K.; Soderquist, Chuck Z.

    2012-07-17

    Assessing the performance of spent (used) nuclear fuel in geological repository requires quantification of time-dependent phenomena that may influence its behavior on a time-scale up to millions of years. A high-level waste repository environment will be a dynamic redox system because of the time-dependent generation of radiolytic oxidants and reductants and the corrosion of Fe-bearing canister materials. One major difference between used fuel and natural analogues, including unirradiated UO2, is the intense radiolytic field. The radiation emitted by used fuel can produce radiolysis products in the presence of water vapor or a thin-film of water (including OH• and H• radicals, O2-, eaq, H2O2, H2, and O2) that may increase the waste form degradation rate and change radionuclide behavior. H2O2 is the dominant oxidant for spent nuclear fuel in an O2 depleted water environment, the most sensitive parameters have been identified with respect to predictions of a radiolysis model under typical conditions. As compared with the full model with about 100 reactions it was found that only 30-40 of the reactions are required to determine [H2O2] to one part in 10–5 and to preserve most of the predictions for major species. This allows a systematic approach for model simplification and offers guidance in designing experiments for validation.

  16. Radiolysis of berberine or palmatine in aqueous solution

    Science.gov (United States)

    Marszalek, Milena; Wolszczak, Marian

    2011-01-01

    The reactions of hydrated electron (eaq-), hydrogen atom (H rad ) (reducing species) and Cl2•-, Br2•-, N,O•H radicals (oxidizing species) with berberine or palmatine in aqueous solution have been studied by steady-state and pulse radiolysis. The spectra of transient intermediates, leading to the final products, are presented. The rate constants of the reaction of eaq- and rad OH radical with both alkaloids in the homogenous solution and in the presence of DNA are reported. It is demonstrated that the primary products of the reaction of berberine and palmatine with eaq- and radicals generated during radiolysis are unstable and undergo further reactions.

  17. Reaction mechanisms in the radiolysis of peptides, polypeptides and proteins

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, W.M.

    1985-01-01

    The purpose of this review is to bring together and to correlate the wide variety of experimental studies that provide information on the reaction products and reaction mechanisms involved in the radiolysis of peptides, polypeptides and proteins (including chromosomal proteins) in both aqueous and solid-state systems. The comparative radiation chemistry of these systems is developed in terms of specific reactions of the peptide main-chain and the aliphatic, aromatic-unsaturated and sulfur-containing side-chains. Information obtained with the various experimental techniques of product analysis, competition kinetics, spin-trapping, pulse radiolysis and ESR spectroscopy is included. 147 refs.

  18. gamma-radiolysis and pulse radiolysis of aqueous 4-chloroanisole

    DEFF Research Database (Denmark)

    Quint, R.M.; Park, H.R.; Krajnik, P.

    1996-01-01

    by addition to all aromatic ring positions to yield hydroxycyclohexadlenyl radicals (OH-adducts), k (OH + 4-ClAn) = 6.5 x 10(9) dm(3) mol(-1) s(-1). Those OH-adducts formed on ipso positions of the molecule subsequently undergo HCl or CH3OH elimination forming methoxyphenoxyl- and chlorophenoxyl radicals...... products as intermediates en route to complete mineralization in oxygenated solution indicate that high energy radiation is a promising method for degradation of halogenated aromatic compounds in water. Variation of dose rates from 79 Gy min(-1) to 266 Gy min(-1) did not show any influence on the product...

  19. Radiolysis of berberine or palmatine in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Marszalek, Milena [Institute of Applied Radiation Chemistry, Technical University of Lodz, Wroblewskiego 15, 93-590 Lodz (Poland); Wolszczak, Marian, E-mail: marianwo@mitr.p.lodz.p [Institute of Applied Radiation Chemistry, Technical University of Lodz, Wroblewskiego 15, 93-590 Lodz (Poland)

    2011-01-15

    The reactions of hydrated electron (e{sub aq}{sup -}), hydrogen atom (H{sup {center_dot}}) (reducing species) and Cl{sub 2}{sup {center_dot}}{sup -},Br{sub 2}{sup {center_dot}}{sup -},{sup {center_dot}}N{sub 3},{sup {center_dot}}OH radicals (oxidizing species) with berberine or palmatine in aqueous solution have been studied by steady-state and pulse radiolysis. The spectra of transient intermediates, leading to the final products, are presented. The rate constants of the reaction of e{sub aq}{sup -} and {sup {center_dot}}OH radical with both alkaloids in the homogenous solution and in the presence of DNA are reported. It is demonstrated that the primary products of the reaction of berberine and palmatine with e{sub aq}{sup -} and radicals generated during radiolysis are unstable and undergo further reactions.

  20. Kinetics of the reactions H+C2H4->C2H5, H+C2H5->2CH3 and CH3+C2H5->products studies by pulse radiolysis combined with infrared diode laser spectroscopy

    DEFF Research Database (Denmark)

    Sillesen, A.; Ratajczak, E.; Pagsberg, P.

    1993-01-01

    Formation of methyl radicals via the consecutive reactions H+C2H4+M-->C2H5+M (1) and H+C2H5-->CH3+CH3 (2a) was initiated by pulse radiolysis of 10-100 mbar H-2 in the presence of ethylene. The kinetics of CH3 Were studied by monitoring the transient infrared absorption at the Q(3, 3) line of the v2......=0-->1 vibrational transition at 606.12 cm-1. Reaction (2a) proceeds in competition with the reaction H+C2H5+M-->C2H6+M (2b). The methyl radicals are consumed by CH3+CH3+M-->C2H6+M (3), CH3+C2H5-->products (4), and H+CH3+M-->CH4+ M (5). By computer simulations based on determined absolute radical yields...

  1. Kinetics and branching ratios of the reactions NH2+NO2->N2O+H2O and NH2+NO2->H2NO+NO studied by pulse radiolysis combined with time-resolved infrared diode laser spectroscopy

    DEFF Research Database (Denmark)

    Meunier, H.; Pagsberg, Palle Bjørn; Sillesen, A.

    1996-01-01

    The source reaction F + NH3 --> HF + NH2 was initiated by the pulse radiolysis of NH3/SF6 mixtures, and the primary yield of F atoms was determined by monitoring the decrease in the infrared absorption of methane consumed in the titration reaction F + CH4 --> HF + CH3. The title reactions have been...... studied by monitoring the decay of NH2 and the simultaneous formation of N2O and NO by time-resolved infrared diode laser spectroscopy. The decay rate of NH2 was studied as a function of NO2 concentration to obtain an overall rate constant k(NH2 + NO2) = (1.35 +/- 0.15) X 10(-11) molecule(-1) cm(3) s(-1...

  2. 吲哚荷尔蒙自由基脉冲辐解光谱及其酸基平衡和还原电位性质研究%The spectral, acid-base equilibrium and reduction potential properties of indole hormone radicals: a pulse radiolysis study

    Institute of Scientific and Technical Information of China (English)

    H He; M Lin; Z Han; Y Muroya; H Kudo; Y Katsumura; M Iwata

    2005-01-01

    The Absorption spectral, acid-base equilibrium potential properties and formation and decay kinetics of four kinds of radicals from natural existing indole hormones were studied by pulse radiolysis.One of the most important properties for these four indolyl hormones, melatonin, 5-methoxygramine (MTA),5-methoxy-N, N-dimethylthytrytamine (DMM TA) and 5-methoxy-N, N-diethylthytrytamine (DEMT A), which are involved in biochemical processes and play crucial roles in many neuropathy and cancer related diseases, is their facile one electron oxidation with formation of radical cations or their conjugated base, the indolyl radicals.Formation kinetics and properties of the radicals were investigated by pulse radiolysis using the Linac accelerator with fast time-resolving optical system in UTNL.In the present study, these radicals were generated through oxidation of the corresponding hormone with azide radical in radiation induced process. Their spectroscopic properties were investigated and it was found that the transient spectra in all these cases exhibit similar absorption and pH dependence: in acidic solution, the radicals are characterized with three absorption maxima around 320-350, 440-460, 520-550nm. The spectra of MTA at various pH were shown as an example. From the absorption changes as a function of pH, two pK values were determined to be around 5 and 9 for the indolyl radicals except for melatonin, in which, only one pK was distinguished to be 4.4. Formation kinetics of the radicals was measured by following the growth of their absorption peaks and it was found that these indolyl derivatives transfer an electron to N3, with different rate constants, i.e.1.2×1010, 4.5×109, 4.9×109, 1.6×109 dm3 mol-1 s-1 for melatonin, MTA, DMMTA, and DEMTA, respectively.Reduction potentials of the radicals vs their molecules were also determined and they are dependent on the pH of medium. At pH 7, the reduction potentials were estimated to be 1.10, 1.18, 1.18, 1.20eV for

  3. Radiolysis studies of aqueous kappa-carrageenan

    Energy Technology Data Exchange (ETDEWEB)

    Abad, L.V., E-mail: lvabad@pnri.dost.gov.p [Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines); Kudo, H. [Nuclear Professional School, Graduate School of Engineering, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Saiki, S. [Nuclear Professional School, Graduate School of Engineering, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Quantum Beam Science Directorate, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagasawa, N.; Tamada, M. [Quantum Beam Science Directorate, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Fu, H.; Muroya, Y. [Nuclear Professional School, Graduate School of Engineering, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Lin, M.; Katsumura, Y. [Nuclear Professional School, Graduate School of Engineering, University of Tokyo, 2-22 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1188 (Japan); Advanced Science Research Center, Japan Atomic Energy Agency, 2-4 Shirakata-Shirane, Tokai, Naka, Ibaraki 319-1195 (Japan); Relleve, L.S.; Aranilla, C.T.; DeLaRosa, A.M. [Philippine Nuclear Research Institute, Diliman, Quezon City (Philippines)

    2010-05-15

    The effects on N{sub 2}O and N{sub 2} gas on the radiation degradation yield of aqueous kappa (kappa-) carrageenan were investigated. The G{sub d} of solution saturated with N{sub 2}O solution was expectedly much higher than in air (1.7 and 1.2 x 10{sup -7} mol J{sup -1}). On the other hand, a lower G{sub d} of 1.1 x 10{sup -7} mol J{sup -1} was obtained from kappa-carrageenan solution saturated with N{sub 2}. The rate constant of reaction of OH radicals with sonicated and irradiated kappa-carrageenan were determined using e-beam pulse radiolysis. The rate constant of OH{sup c}entre dot interaction with sonicated kappa-carrageenan decreased with decreasing molecular weight. On the other hand, the OH{sup c}entre dot interaction with irradiated kappa-carrageenan decreased but did not vary significantly with decreasing molecular weight. Metal ion (Na{sup +}) induced conformational transition into helical form decreased the rate constant of OH{sup c}entre dot reaction with kappa-carrageenan. Likewise, the G{sub d} in aqueous form was affected by the conformational state of kappa-carrageenan. The helical conformation gave a lower G{sub d} (7 x 10{sup -8} mol J{sup -1}) than the coiled conformation (G{sub d} = 1.2 x 10{sup -7} mol J{sup -1}).

  4. Radiolysis study of genistein in methanolic solution

    Science.gov (United States)

    Jung, Hee Jin; Park, Hae Ran; Jung, Uhee; Jo, Sung Kee

    2009-06-01

    The aim of the present work was to identify products obtained from genistein by ionizing radiation and to enhance the antioxidant properties of genistein through radiation-induced transformation. Genistein dissolved in methanol was irradiated γ-rays at a dose of 100 kGy. NMR and (HR) EI-MS spectroscopy were used to identify radiolysis products (GM1 and GM2). We proposed that rad CH 2OH may be implicated in the formation GM1 and GM2 during radiolysis of genistein in methanol. The genistein in methanol solution showed higher DPPH radical scavenging activity after γ-irradiation. Then, the antioxidant activities of radiolysis products were evaluated and compared to those of genistein.

  5. Application of chemsimul for groundwater radiolysis

    DEFF Research Database (Denmark)

    Christensen, Hilbert; Bjergbakke, Erling

    1986-01-01

    The application of the radiation chemical computer program chemsimul, for the calculation of radiolysis in connection with the storage of high level waste has been studied. Methods have been developed for the diffusion of gases out of the irradiated system, for the continuous addition of Fe2...

  6. {gamma}-radiolysis of uranous nitrate solutions

    Energy Technology Data Exchange (ETDEWEB)

    Bisel, Isabelle; Lebouille, Odile; Rossetti, Thomas [CEA ValRHo - BP 17171 - 30207 Bagnols sur Ceze (France)

    2008-07-01

    Full text of publication follows: The knowledge of uranous nitrate solutions stability under radiolysis effect is of interest for all the processes aiming its co-conversion into a solid form with other actinides. In the presence of hydrazine, the oxidation of U(IV) to U(VI) under {gamma}-radiolysis ({sup 137}Cs) is due to the reaction with water radiolysis products, mainly hydrogen peroxide. Its kinetic law is of order 0. In addition, the zero order hydrazine consumption reaction, leads to the accumulation of hydrazoic acid related to its oxidation by nitrous acid himself generated by the radiolysis of the nitric acid. Lastly, the increase of acidity of the solution with a stoichiometry of 1.5 compared to uranium indicates multiple reactions. In absence of hydrazine, uranous nitrate is very quickly oxidized by the nitric and solutions acidity increases according to a complex mechanism catalysed by the nitrous acid. Results are not found to be sensitive to dose rate between 10 and 300 Gy/min. (authors)

  7. Application of chemsimul for groundwater radiolysis

    DEFF Research Database (Denmark)

    Christensen, Hilbert; Bjergbakke, Erling

    1986-01-01

    The application of the radiation chemical computer program chemsimul, for the calculation of radiolysis in connection with the storage of high level waste has been studied. Methods have been developed for the diffusion of gases out of the irradiated system, for the continuous addition of Fe2+ to ...

  8. A Comparison of the ?-Radiolysis of TODGA and T(EH)DGA Using UHPLC-ESI-MS Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zarzana, Chris A.; Groenewold, Gary S.; Mincher, Bruce J.; Mezyk, Stephen P.; Modolo, Giuseppe; Wildens, Andreas; Schmidt, Holgar; Wishart, James F.; Cook, Andrew R.

    2015-03-01

    Solutions of TODGA and T(EH)DGA in n-dodecane were subjected to ?-irradiation in the presence and absence of an aqueous nitric acid phase and analyzed using UHPLC-ESI-MS to determine the rates of radiolytic decay of the two extractants, as well as to identify radiolysis products. The DGA concentrations decreased exponentially with increasing dose, and the measured degradation rate constants were uninfluenced by the presence or absence of an acidic aqueous phase, or by chemical variations in the alkyl side-chains. The DGA degradation was attributed to reactions of the dodecane radical cation, whose kinetics were measured for TODGA using picosecond electron pulse radiolysis to be k2 = (9.72 ± 1.10) × 109 M-1 s-1. The identified radiolysis products suggest that the bonds most vulnerable to radiolytic attack are those in the diglycolamide center of these molecules and not on the side-chains.

  9. Degradation mechanisms of the ethylene carbonate/diethyl carbonate mixture studied by radiolysis

    OpenAIRE

    Wang, Furong; Varenne, Fanny; Ortiz, Daniel; Pinzio, Valentin; Mostafavi, Mehran; Le Caer, Sophie

    2017-01-01

    International audience; The reactivity of ethylene carbonate (EC) and of the ethylene carbonate/diethyl carbonate (DEC) mixture is studied under ionizing radiation in order to mimic aging phenomena occurring in lithium-ion batteries. Picosecond pulse radiolysis experiments show that the attachment of the electron on EC molecule is ultrafast (k(e-EC + EC) = 1.3  109 L mol-1 s-1 at 46°C). In the case of the 50/50 EC/DEC mixture, just after the electron pulse, the electron is solvated by a mixt...

  10. Effect of nitrogen and oxygen on radiolysis of iodide solution

    Energy Technology Data Exchange (ETDEWEB)

    Karasawa, H.; Endo, M. [Hitachi Ltd., Power and Industrial System R+D Divisions, Ibaraki (Japan)

    1996-12-01

    The effect of nitrogen and oxygen on radiolysis of iodide solution was examined. Direct decomposition of nitrogen by {gamma}-radiation produced nitric acid to decrease a water pH. This resulted in the iodine formation in the radiolysis of iodide solution. Hydrogen peroxide was produced by the radiolysis of water containing oxygen. This worked a reducing agent to suppress the formation of iodine in the radiolysis of iodide solution. In the analytical model, fourteen iodine species were considered and reaction scheme consisted in 124 reactions. The analytical model could estimate the oxidation state of iodide ions. (author) 4 figs., 4 refs.

  11. The radiolysis of lithium oxide ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Tiliks, J.; Supe, A.; Kizane, G.; Tiliks, J. Jr. [Latvia Univ., Riga (Latvia). Dept. of Chemistry; Grishmanov, V.; Tanaka, S.

    1998-03-01

    The radiolysis of Li{sub 2}O ceramics exposed to accelerated electrons (5 MeV) at 380 K was studied in the range of high absorbed doses up to 250 MGy. The formation of radiation defects (RD) and radiolysis products (RP) was demonstrated to occur simultaneously in the regions of (1) the regular crystalline lattice and (2) an enhanced content of the intrinsic defects and impurities. The production of the electronic RD and RP is more efficient in the region of the defected lattice than that at the site of the regular crystalline lattice. However, the stability of RD and RP formed in the region of the intrinsic defects is far less than those produced at the crystalline lattice, since most of the first mentioned RD and RP disappears with irradiation dose due to the radiation stimulated recombination. By this means the enhanced quantity of RD and RP is localized in the Li{sub 2}O ceramics irradiated to absorbed dose of 40-50 MGy, and hence this can influence the tritium release parameters. As soon as the intrinsic defects have been consumed in the production of RD and RP and the recombination of unstable electronic RD and RP takes place (at dose of {approx}100 MGy), the radiolysis of Li{sub 2}O ceramics occurs only at the crystalline lattice. Furthermore, the concentration of RD and RP increases monotonically and tends to the steady-state level. (author)

  12. Pulse

    Science.gov (United States)

    ... resting for at least 10 minutes. Take the exercise heart rate while you are exercising. ... pulse rate can help determine if the person's heart is pumping. Pulse ... rate gives information about your fitness level and health.

  13. Radiolysis of cyanocobalamin (vitamin B 12)

    Science.gov (United States)

    Juanchi, X.; Albarran, G.; Negron-Mendoza, A.

    2000-03-01

    Research on the radiolysis of vitamins is of considerable interest since these compounds are important nutritional constituents in foods and in dietetic supplements. In spite of these considerations there are few data and very often difficult to compare for the radiolytic behavior of vitamins. In this work we focused our attention on to the study of the radiolysis of cyanocobalamin (vitamin B 12) in solid state and in aqueous solutions. The procedure was followed by HPLC and UV-spectroscopy. The results obtained in aqueous solutions showed a dependence of the decomposition as a linear function of the dose. The G of decomposition for a 1×10 -5 M solution was 3.3. In the solid state the vitamin was very stable towards the irradiation in the conditions used in this study with a G=2.1×10 -3. A study made with Serratia marcescens as a microbiological contaminant showed that at the sterilization dose there is a destruction of the vitamin in aqueous solution. In the solid state the degree of decomposition was 7%.

  14. Radiolysis Model Sensitivity Analysis for a Used Fuel Storage Canister

    Energy Technology Data Exchange (ETDEWEB)

    Wittman, Richard S.

    2013-09-20

    This report fulfills the M3 milestone (M3FT-13PN0810027) to report on a radiolysis computer model analysis that estimates the generation of radiolytic products for a storage canister. The analysis considers radiolysis outside storage canister walls and within the canister fill gas over a possible 300-year lifetime. Previous work relied on estimates based directly on a water radiolysis G-value. This work also includes that effect with the addition of coupled kinetics for 111 reactions for 40 gas species to account for radiolytic-induced chemistry, which includes water recombination and reactions with air.

  15. Picosecond pulse radiolysis of the liquid diethyl carbonate.

    Science.gov (United States)

    Torche, Fayçal; El Omar, Abdel Karim; Babilotte, Philippe; Sorgues, Sébastien; Schmidhammer, Uli; Marignier, Jean-Louis; Mostafavi, Mehran; Belloni, Jacqueline

    2013-10-24

    The diethyl carbonate, DEC, is an ester that is used as a solvent in Li-ion batteries, but its behavior under ionizing radiation was unknown. The transient optical absorption spectra, the decay kinetics, and the influence of various scavengers have been studied by using the picosecond laser-triggered electron accelerator ELYSE. In neat DEC, the intense near-IR (NIR) absorption spectrum is assigned to the solvated electron. It is overlapped in the visible range by another transient but longer-lived and less intense band that is assigned to the oxidized radical DEC(-H). The solvated electron molar absorption coefficients and radiolytic yield evolution from 25 ps, the geminate recombination kinetics, and the rate constants of electron transfer reactions to scavengers are determined. The radiolytic mechanism, indicating a certain radioresistance of DEC, is compared with that for other solvents.

  16. Redox chemistry of - and -hydroxycinnamic acids: A pulse radiolysis study

    Indian Academy of Sciences (India)

    P Yadav; H Mohan; B S M Rao; J P Mittal

    2002-12-01

    Radiation chemical reactions of ${}^{\\bullet}$OH, O$^{\\bullet -}$, N$_{3}^{\\bullet}$ and $e^{-}_{aq}$ with - and -hydroxycinnamic acids were studied. The second-order rate constants for the reaction of ${}^{\\bullet}$OH with ortho and meta isomers in buffer solution at H 7 are 3.9 ± 0.2 × 109 and 4.4 ± 0.3 × 109 dm3 mol-1 s-1 respectively. At H 3 the rate with the ortho isomer was halved (1.6 ± 0.4 × 109 dm3 mol-1 s-1) but it was unaffected in the case of meta isomer ( = 4.2 ± 0.6 × 109 dm3 mol-1 s-1). The rate constant in the reaction of N$_{3}^{\\bullet}$ with the ortho isomer is lower by an order of magnitude ( = 4.9 ± 0.4 × 108 dm3 mol-1s-1). The rates of the reaction of $e^{-}_{aq}$ with ortho and meta isomers were found to be diffusion controlled. The transient absorption spectrum measured in the ${}^{\\bullet}$OH with -hydroxycinnamic acid exhibited an absorption maximum at 360 nm and in meta isomer the spectrum was blue-shifted (330 nm) with a shoulder at 390 nm. A peak at 420 nm was observed in the reaction of O$^{\\bullet-}$ with the -isomer whereas the meta isomer has a maximum at 390 and a broad shoulder at 450 nm. In the reaction of $e^{-}_{aq}$, the absorption peaks were centred at 370-380 nm in both the isomers. The underlying reaction mechanism is discussed.

  17. Stability of DMHAN on 238Pu α-Radiolysis

    Institute of Scientific and Technical Information of China (English)

    WANG; Liang; HE; Hui; SONG; Peng

    2013-01-01

    238Pu was used asαliquid inside source(does rate:34.0 Gy·g-1·min-1)for the radiolysis of N,N-dimethylhydroxylamine(DMHAN).DMHAN can reduce Pu(Ⅳ)efficiently,in nitric acid solution,Pu should be trivalence while DMHAN exists.Characteristic wavelength of Pu(Ⅲ)and Pu(Ⅳ)in radiolysis

  18. Radiolysis of Serine in High Radiation Field

    Directory of Open Access Journals (Sweden)

    Ellen Y. Aguilar-Ovando

    2016-08-01

    Full Text Available The formation of amino acids under simulated condition suggests that this type of compounds were readily formed on the primitive Earth. Nevertheless, there is no conclusive explanation to the origin of their specific chirality in biological systems. Differences in their stability in the primitive conditions may give some clues about this unsolved problem. Protection mechanisms have been considered, such as the adsorption of the organic compounds onto mineral surfaces. By using HPLC/ELSD to analyze aqueous suspensions of serine adsorbed on clay (sodium montmorillonite and a meteorite (Allende irradiated in different doses with a cobalt-60 gamma source, the aim of this work was to study the possible protector role of these mineral surfaces when an amino acid, serine, is adsorbed onto them and the system is exposed to a high radiation source. The results showed that adsorption is better at acidic pH and desorption from the mineral at basic pH. The irradiation of the free amino acid destroyed it almost completely at a dose of 91 kGy, but the presence of the mineral abruptly decreases the decomposition, acting as a protective agent. At the same time, the results in aqueous solution show no statistically significant differences in adsorption or radiolysis of D and L serine.

  19. Radiolysis of water with aluminum oxide surfaces

    Science.gov (United States)

    Reiff, Sarah C.; LaVerne, Jay A.

    2017-02-01

    Aluminum oxide, Al2O3, nanoparticles with water were irradiated with γ-rays and 5 MeV He ions followed by the determination of the production of molecular hydrogen, H2, and characterization of changes in the particle surface. Surface analysis techniques included: diffuse reflectance infrared Fourier transform spectroscopy (DRIFT), nitrogen absorption with the Brunauer - Emmett - Teller (BET) methodology for surface area determination, X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). Production of H2 by γ-ray radiolysis was determined for samples with adsorbed water and for Al2O3 - water slurries. For Al2O3 samples with adsorbed water, the radiation chemical yield of H2 was measured as 80±20 molecules/100 eV (1 molecule/100 eV=1.04×10-7 mol/J). The yield of H2 was observed to decrease as the amount of water present in the Al2O3 - water slurries increased. Surface studies indicated that the α-phase Al2O3 samples changed phase following irradiation by He ions, and that the oxyhydroxide layer, present on the pristine sample, is removed by γ-ray and He ion irradiation.

  20. Radical Cations and Acid Protection during Radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Bruce J. Mincher; Christopher A. Zarzana; Stephen P. Mezyk

    2016-09-01

    Ligand molecules for used nuclear fuel separation schemes are exposed to high radiation fields and high concentrations of acid. Thus, an understanding of the complex interactions between extraction ligands, diluent, and acid is critical to understanding the performance of a separation process. The diglycolamides are ligands with important structural similarities to CMPO; however, previous work has shown that their radiolytic degradation has important mechanistic differences from CMPO. The DGAs do not enjoy radioprotection by HNO3 and the kinetics of DGA radiolytic degradation are different. CMPO degrades with pseudo-zero-order kinetics in linear fashion with absorbed dose while the DGAs degrade in pseudo-first-order, exponential fashion. This suggests that the DGAs degrade by simple reaction with some product of direct diluent radiolysis, while CMPO degradation is probably multi-step, with a slow step that is not dependent on the CMPO concentration, and mitigated by HNO3. It is thus believed that radio-protection and the zero-order radiolytic degradation kinetics are related, and that these phenomena are a function of either the formation of strong acid complexes with CMPO and/or to the presence of the CMPO phenyl ring. Experiments to test both these hypotheses have been designed and partially conducted. This report summarizes findings related to these phenomena for FY16, in satisfaction of milestone M3FT-16IN030104053. It also reports continued kinetic measurements for the reactions of the dodecane radical cation with solvent extraction ligands.

  1. Modeling of water radiolysis at spallation neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Daemen, L.L.; Kanner, G.S.; Lillard, R.S.; Butt, D.P.; Brun, T.O.; Sommer, W.F.

    1998-12-01

    In spallation neutron sources neutrons are produced when a beam of high-energy particles (e.g., 1 GeV protons) collides with a (water-cooled) heavy metal target such as tungsten. The resulting spallation reactions produce a complex radiation environment (which differs from typical conditions at fission and fusion reactors) leading to the radiolysis of water molecules. Most water radiolysis products are short-lived but extremely reactive. When formed in the vicinity of the target surface they can react with metal atoms, thereby contributing to target corrosion. The authors will describe the results of calculations and experiments performed at Los Alamos to determine the impact on target corrosion of water radiolysis in the spallation radiation environment. The computational methodology relies on the use of the Los Alamos radiation transport code, LAHET, to determine the radiation environment, and the AEA code, FACSIMILE, to model reaction-diffusion processes.

  2. Summary of TRUEX Radiolysis Testing Using the INL Radiolysis Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Dean R. Peterman; Lonnie G. Olson; Rocklan G. McDowell; Gracy Elias; Jack D. Law

    2012-03-01

    The INL radiolysis and hydrolysis test loop has been used to evaluate the effects of hydrolytic and radiolytic degradation upon the efficacy of the TRUEX flowsheet for the recovery of trivalent actinides and lanthanides from acidic solution. Repeated irradiation and subsequent re-conditioning cycles did result in a significant decrease in the concentration of the TBP and CMPO extractants in the TRUEX solvent and a corresponding decrease in americium and europium extraction distributions. However, the build-up of solvent degradation products upon {gamma}-irradiation, had little impact upon the efficiency of the stripping section of the TRUEX flowsheet. Operation of the TRUEX flowsheet would require careful monitoring to ensure extraction distributions are maintained at acceptable levels.

  3. TRUEX Radiolysis Testing Using the INL Radiolysis Test Loop: FY-2012 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Dean R. Peterman; Lonnie G. Olson; Richard D. Tillotson; Rocklan G. McDowell; Jack D. Law

    2012-09-01

    The INL radiolysis test loop has been used to evaluate the affect of radiolytic degradation upon the efficacy of the strip section of the TRUEX flowsheet for the recovery of trivalent actinides and lanthanides from acidic solution. The nominal composition of the TRUEX solvent used in this study is 0.2 M CMPO and 1.4 M TBP dissolved in n-dodecane and the nominal composition of the TRUEX strip solution is 1.5 M lactic acid and 0.050 M diethylenetriaminepentaacetic acid. Gamma irradiation of a mixture of TRUEX process solvent and stripping solution in the test loop does not adversely impact flowsheet performance as measured by stripping americium ratios. The observed increase in americium stripping distribution ratios with increasing absorbed dose indicates the radiolytic production of organic soluble degradation compounds.

  4. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    DEFF Research Database (Denmark)

    Draganic, Z.D.; Negrón-Mendoza, A.; Sehested, K.

    1991-01-01

    of formaldehyde and an unidentified polymer. A large initial yield of formate in the gamma-radiolysis, G(HCOO-) = 2.2, is due to the reaction COO- + HCO3- reversible HCOO- + CO3-. The efficiency of organic synthesis within the large dose range studied is low and is explained by efficient pathways leading......Oxygen-free aqueous solutions of 0.05 mol dm-3 ammonium and sodium bicarbonate were studied after receiving various doses of Co-60 gammas (0.01-400 kGy) or 0.5-20 Gy pulses of 10 Mev electrons. Formate and oxalate were found to be the main radiolytic products, in addition to trace amounts...

  5. Valine radiolysis by MeV ions

    Science.gov (United States)

    Da Silveira, Enio

    2016-07-01

    Valine, (CH3)2 CHCH (NH2) COOH, is a protein amino acid that has been identified in extraterrestrial environments and in the Murchison meteorite [1]. The knowledge of half-lives of small organic molecules under ionizing radiation is important for the setup of models describing the spread out of prebiotics across the Solar System or the Galaxy. We have investigated typical effects of MeV cosmic ray ions on prebiotic molecules in laboratory by impinging ions produced by the PUC-Rio Van de Graaff accelerator. Pure valine films, deposited by evaporation on KBr substrates, were irradiated by H ^{+}, He ^{+} and N ^{+} ion beams, from 0.5 to 1.5 MeV and up to a fluence of 10 ^{15} projectiles/cm ^{2}. The sample temperature was varied from 10 K to 300 K. The irradiation was interrupted several times for Mid-FTIR analysis of the sample. The main findings are: 1- The column density of the valine decreases exponentially with fluence. 2- In some cases, a second exponential appears in the beginning of irradiation; this feature has been attributed to sample compaction by the ion beam [2]. 3- Destruction cross sections of valine are in the 10 ^{-15} cm ^{2} range, while compaction cross sections are in the 10 ^{-14} cm ^{2} range. 4- Destruction cross section increases with the stopping power of the beam and also with the sample temperature. 5- Surprisingly, during the radiolysis of valine, just CO _{2} is seen by as a daughter molecule formed in the bulk. 6- After long beam fluence, also a CO peak appears in the infrared spectrum; this species is however interpreted as a fragment of the formed CO2 molecules. 7- Considering the flux ratio between laboratory experiments and actual galactic cosmic rays, half-life of valine is predicted for ISM conditions [3]. This work on pure valine is the first measurement of a series. New experiments are planned for determining cross sections of valine dissolved in H _{2}O or CO _{2}, inspired by the study performed for glycine [4]. [1] P

  6. Radiolysis effects in sub-cooled nucleate boiling

    Energy Technology Data Exchange (ETDEWEB)

    Dickinson, S.; Henshaw, J.; Tuson, A.; Sims, H.E. [AEA Technology (United Kingdom)

    2002-07-01

    A hydrogen depleted region may form in the water during bubble formation when boiling occurs in a PWR. This would arise from stripping of gases into the steam phase. The depleted water may then become oxidising due to radiolysis forming H{sub 2}O{sub 2}. The presence of radiolytic oxidising conditions is one of the mechanisms proposed to explain deposits formed in Axial Offset Anomalies. This work describes a model that has been developed to examine this behaviour. The model deals with bubble growth and material transport as well as the radiolysis chemistry. The model simulates diffusion of species through the gas/liquid boundary layer. The appropriate mass conservation equations for this problem are described and the results of their numerical solution discussed. This model indicates the importance of the assumed boundary conditions on the results of the calculations. These boundary conditions are discussed in detail and the most appropriate ones for the actual reactor situation are outlined. The conclusion of this modelling study is that at normal PWR operating conditions of 40 cc H{sub 2} (STP) kg{sup -1} it is unlikely that radiolysis in a subcooled boiling region would be important. The situation is more ambiguous at the 1 to 5 cc H{sub 2} (STP) kg{sup -1} range. (author)

  7. Reactivity of OH radicals with chlorobenzoic acids-A pulse radiolysis and steady-state radiolysis study

    DEFF Research Database (Denmark)

    Zona, Robert; Solar, Sonja; Getoff, Nikola

    2010-01-01

    the degradation rates induced by gamma radiation were very similar for all chlorobenzoic acids, yet the chloride formation was distinctly higher for 3-ClBzA. In the presence of oxygen the initial degradation of 2-and 4-ClBzA equaled the OH-radical concentration, whereas in case of 3-ClBzA only 60% of OH led...

  8. Reaction mechanisms in the radiolysis of peptides, polypeptides and proteins II reactions at side-chain loci in model systems

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, W.M.

    1983-11-01

    The major emphasis in radiation biology at the molecular level has been on the nucleic acid component of the nucleic acid-protein complex because of its primary genetic importance. But there is increasing evidence that radiation damage to the protein component also has important biological implications. Damage to capsid protein now appears to be a major factor in the radiation inactivation of phage and other viruses. And, there is increasing evidence that radiation-chemical change in the protein component of chromation leads to changes in the stability of the repressor-operator complexes involved in gene expression. Knowledge of the radiation chemistry of protein is also of importance in other fields such as the application of radiation sterilization to foods and drugs. Recent findings that a class of compounds, the ..cap alpha..,..cap alpha..'-diaminodicarboxylic acids, not normally present in food proteins, are formed in protein radiolysis is of particular significance since certain of their peptide derivatives have been showing to exhibit immunological activity. The purpose of this review is to bring together and to correlate our present knowledge of products and mechanisms in the radiolysis of peptides, polypeptides and proteins both aqueous and solid-state. In part 1 we presented a discussion of the radiation-induced reactions of the peptide main-chain in model peptide and polypeptide systems. Here in part 2 the emphasis is on the competing radiation chemistry at side-chain loci of peptide derivatives of aliphatic, aromatic-unsaturated and sulfur-containing amino acids in similar systems. Information obtained with the various experimental techniques of product analysis, competition kinetics, spin-trapping, pulse radiolysis, and ESR spectroscopy are included.

  9. Water Sorption and Radiolysis Studies for Neptunium Oxides

    Energy Technology Data Exchange (ETDEWEB)

    Icenhour, A.S.

    2004-02-03

    Plans are to convert the {sup 237}Np that is currently stored as a nitrate solution at the Savannah River Site to NpO{sub 2} and then ship it to the Y-12 National Security Complex in Oak Ridge for interim storage. This material will serve as feedstock for the {sup 238}Pu production program, and some will be periodically shipped to the Oak Ridge National Laboratory (ORNL) for fabrication into targets. The safe storage of this material requires an understanding of the radiolysis of moisture that is sorbed on the oxides, which, in turn, provides a basis for storage criteria (namely, moisture content). A two-component experimental program has been undertaken at ORNL to evaluate the radiolytic effects on NpO{sub 2}: (1) moisture uptake experiments and (2) radiolysis experiments using both gamma and alpha radiation. These experiments have produced two key results. First, the water uptake experiments demonstrated that the 0.5 wt % moisture limit that has been typically established for similar materials (e.g., uranium and plutonium oxides) cannot be obtained in a practical environment. In fact, the uptake in a typical environment can be expected to be at least an order of magnitude lower than the limit. The second key result is the establishment of steady-state pressure plateaus as a result of the radiolysis of sorbed moisture. These plateaus are the result of back reactions that limit the overall pressure increase and H{sub 2} production. These results clearly demonstrate that 0.5 wt % H{sub 2}O on NpO{sub 2} is safe for long-term storage--if such a moisture content could even be practically reached.

  10. Removal of chloroform from biodegradable therapeutic microspheres by radiolysis.

    Science.gov (United States)

    Zielhuis, S W; Nijsen, J F W; Dorland, L; Krijger, G C; van Het Schip, A D; Hennink, W E

    2006-06-06

    Radioactive holmium-166 loaded poly(l-lactic acid) microspheres are promising systems for the treatment of liver malignancies. These microspheres are loaded with holmium acetylacetonate (HoAcAc) and prepared by a solvent evaporation method using chloroform. After preparation the microspheres (Ho-PLLA-MS) are activated by neutron irradiation in a nuclear reactor. It was observed that relatively large amounts of residual chloroform (1000-6000 ppm) remained in the microspheres before neutron irradiation. Since it is known that chloroform is susceptible for high-energy radiation, we investigated whether neutron and gamma irradiation could result in the removal of residual chloroform in HoAcAc-loaded and placebo PLLA-MS by radiolysis. To investigate this, microspheres with relatively high and low amounts of residual chloroform were subjected to irradiation. The effect of irradiation on the residual chloroform levels as well as other microsphere characteristics (morphology, size, crystallinity, molecular weight of PLLA and degradation products) were evaluated. No chloroform in the microspheres could be detected after neutron irradiation. This was also seen for gamma irradiation at a dose of 200 kGy phosgene, which can be formed as the result of radiolysis of chloroform, was not detected with gas chromatography-mass spectrometry (GC-MS). A precipitation titration showed that radiolysis of chloroform resulted in the formation of chloride. Gel permeation chromatography and differential scanning calorimetry showed a decrease in molecular weight of PLLA and crystallinity, respectively. However, no differences were observed between irradiated microsphere samples with high and low initial amounts of chloroform. In conclusion, this study demonstrates that neutron and gamma irradiation results in the removal of residual chloroform in PLLA-microspheres.

  11. Fenton-enhanced {gamma}-radiolysis of cyanuric acid

    Energy Technology Data Exchange (ETDEWEB)

    Varghese, Rani [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India); Aravind, Usha K. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India); Aravindakumar, Charuvila T. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India)]. E-mail: CT-Aravindakumar@rocketmail.com

    2007-04-02

    Degradation of cyanuric acid (OOOT), a stable end product of oxidative decomposition of atrazine, is investigated in a combined field of gamma radiolysis and fenton reaction. The reaction of hydroxyl radical ({center_dot}OH) at pH 6 was carried out by irradiating N{sub 2}O saturated aqueous solutions containing OOOT (1 x 10{sup -3} mol dm{sup -3}), and this resulted only a marginal degradation (20%). However, when the same reaction was carried out in the presence of varying concentrations of ferrous sulfate ((5-10) x 10{sup -5} mol dm{sup -3}), the decay of OOOT has been enhanced to more than 80%. This decay followed a first order kinetics. Nearly similar effects were observed with another triazine derivative, 2,4-dioxohexahydro-1,3,5-triazine (DHT). Two major reaction mechanisms are proposed for the enhanced decay of OOOT. The formation of unstable hydroxyl radical adducts from the reaction of {center_dot}OH which is the result of gamma radiolysis and the Fenton reaction (resulting from the reaction of the added Fe(II) and of the H{sub 2}O{sub 2} from the radiolysis of water), is proposed as the first mechanism. The second mechanism, which is likely the major contributor to degradation, is proposed as the reaction of a nucleophilic adduct, Fe(II)OOH, which could directly react with the electron deficient triazine ring. It is highlighted that such degradation reactions must be explored for the complete degradation of the byproducts of the oxidative decomposition of atrazine.

  12. Mobile charge carriers in pulse-irradiated poly- and oligothiophenes

    NARCIS (Netherlands)

    Haas, M.P. de; Laan, G.P. van der; Wegewijs, B.; Leeuw, D.M. de; Bäuerle, P.; Rep, D.B.A.; Fichou, D.

    1999-01-01

    Lower limits of the intrinsic charge carrier mobility in the solid phase of a series of oligothiophene compounds were determined with the pulse-radiolysis time-resolved microwave conductivity technique, PR-TRMC. The mobility values fall roughly into two regimes and show no correlation with the numbe

  13. Radiolysis of TBP in the presence of plutonium and uranium

    Energy Technology Data Exchange (ETDEWEB)

    Kulikov, I.A.; Kermanova, N.V.; Vladimirova, M.V.

    The yields of the decomposition products of TBP as the result of ..cap alpha..- and ..gamma..-radiolysis in the two-phase system 30% TBP in n-paraffin-3.0 moles/liter HNO/sub 3/ in the presence of Pu (sup/IV/) (10/sup -3/-10/sup -1/ mole/liter) and U(sup/VI/) (0.01-0.3 mole/liter) are determined by the methods of potentiometry, spectrophotometry, and chromatography. The yields of the formation of complexes of Pu (sup/IV/) with dibutylphosphoric acid (DBPA) and monobutylphosphoric acid (MBPA) are determined in the two-phase system studied. It is shown that with an increase of (Me) from 0.01 to 0.3 mole/liter, G, DBPA is increased from 1.9 to 3.0, and G, MBPA from 0.3 to 0.45 molecules /100 eV. The radiation gas, the composition, and the yields of gaseous radiolysis products of the organic phase are studied. The kinetics of the formation of DBPA in the presence of plutonium are considered. The velocity constants of the formation and decomposition of DBPA are determined. Based on the experimental data, the maximum decomposition yield of TBP is calculated, equal to approx.6.0 molecules/100 eV.

  14. Radiolysis of cyanocobalamin (vitamin B{sub 12})

    Energy Technology Data Exchange (ETDEWEB)

    Juanchi, X.; Albarran, G.; Negron-Mendoza, A

    2000-03-01

    Research on the radiolysis of vitamins is of considerable interest since these compounds are important nutritional constituents in foods and in dietetic supplements. In spite of these considerations there are few data and very often difficult to compare for the radiolytic behavior of vitamins. In this work we focused our attention on to the study of the radiolysis of cyanocobalamin (vitamin B{sub 12}) in solid state and in aqueous solutions. The procedure was followed by HPLC and UV-spectroscopy. The results obtained in aqueous solutions showed a dependence of the decomposition as a linear function of the dose. The G of decomposition for a 1x10{sup -5} M solution was 3.3. In the solid state the vitamin was very stable towards the irradiation in the conditions used in this study with a G=2.1x10{sup -3}. A study made with Serratia marcescens as a microbiological contaminant showed that at the sterilization dose there is a destruction of the vitamin in aqueous solution. In the solid state the degree of decomposition was 7%. (author)

  15. gamma. radiolysis of polyethylene grafted with sytrene. [Gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Mitsui, H.; Shimizu, Y.

    1981-06-01

    ..gamma.. radiolysis of polyethylene grafted with styrene of 0-76 wt % was carried out at 30-100/sup 0/C in vacuo with a dose rate of 6.35 x 10/sup 5/ rad/hr. The formation of hydrogen and trans-vinylene unsaturation decreased as the content of styrene unit in polymer increased and the rate of formulation was described by zero-order formation kinetics with respect to each concentration combined with first-order disappearance. The gel fraction changed with the content of styrene unit according to irradation time and temperature. The gel data were evaluated by using the Charlesby-Pinner equation. Kinetic analysis showed that in ..gamma.. radiolysis of polyethylene grafted with styrene the formation of hydrogen is somewhat retarded, the crosslinking and main chain scission are accelerated, and the disappearance of hydrogen and formation and disappearance of trans-vinylene unsaturation are almost entirely unaffected. On the basis of these results the reactions induced by ..gamma.. rays in graft polymer were discussed in connection with the reaction mechanisms of the ..gamma.. radiolyses of polyethylene and polystyrene.

  16. Radiolysis of Reactive Azo Dyes in Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Agustin N.M. Bagyo

    2004-07-01

    Full Text Available The effects of radiation on aerated reactive dye solutions i.e Cibacron Violet, Cibacron Orange and Cibacron Yellow solutions have been studied. Parameters analysis were the change of pH after radiation, the change of absorption, degradation products and effects of pH on the radiolysis. The uv-vis absorption of solutions were observed before and after irradiation. pH variation was done from pHs 3, 5, 7, 9 and 12. Irradiation was done at doses of 0, 2, 4, 6, 8 and 10 kGy with dose rate of 5 kGy/h and was determined by a Fricke dosimeter. HPLC with UV detector was used to analyze the degradation products. Oxalic acid was the main degradation product and small amount of succinic acid was also detected.

  17. Study of proton radiolysis of solid uracil film

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    In order to understand the molecules mechanism of ion irradiation,which has been widelyused in many fields such as cancer therapy, uracil, one of the bases ofnucleic acid,waschosen in the low energy ion radiolysis research. The solid uracil films with mass thickness of0.314 mg/cm2 were irradiated by 200 keV H+ ions.The experimental results show that 200 keVH+ ions are effective in decomposition of uracil molecules. One of the decomposition products,5,6-dihydro-uracil, was separated by high performance liquid chromatograph (HPLC) anddetected using an UV-light detector. Its yield increases first but then decreases as the ion doseincreasing. In addition, the mechanism of uracil decomposition and 5,6-dihydro-uracilformation was also discussed.

  18. The radiolysis of iodine in aqueous solutions containing methane

    Science.gov (United States)

    Paquette, Jean; Ford, Beverly L.

    The γ-radiolysis of iodine, iodine, iodate and periodate solutions containing methane has been investigated. Iodoalkanes are produced in these solutions upon irradiation. In the case of unbuffered iodine, iodate and periodate solutions at an initial concentration of 1.0 × 10 -4 mol dm -3, nearly all of the initial iodine is transformed into iodoalkanes after the absorption of a 4 kGy radiation dose. The yield of iodoalkanes is lower for iodine solutions and for iodide solutions buffered at neutral pH. It is concluded that the main reactions leading to the formation of iodoalkanes are CH 3+I 2→CH 3I+I and CH 3+I→CH 3I. In the case of iodate and periodate, these reactions could be preceeded by reactions involving the methyl radical and oxyiodine species: CH 3+IO x→CH 2O+HIO x-1.

  19. Radiolysis of pentachlorophenol (PCP) in aqueous solution by gamma radiation

    Institute of Scientific and Technical Information of China (English)

    XUE Jun; WANG Jianlong

    2008-01-01

    Steady-state radiolysis experiments were performed to investigate the y-irradiation treatment of pentachlorophenol (PCP) in aqueoussolution. The effect of initial concentration on the PCP degradation was also investigated. The experimental results showed that γ-irradiation was able to degrade PCP in aqueous solution successfully, and the radiolytical degradation process of PCP could be describedby the first-order kinetic model. When the initial concentration of PCP was 25 and 50 mg/L and the radiation dose was 4 and 6 kGy,respectively, the degradation efficiency was 100%. A luminescence bacterial test was used for evaluating the toxicity of the radiolyticintermediate products. Total detoxification of a 75 mg/L PCP solution could be achieved by carrying out the irradiation procedure at the dose of 15 kGy.

  20. Solid state radiolysis of amino acids in an astrochemical perspective

    Science.gov (United States)

    Cataldo, Franco; Angelini, Giancarlo; Iglesias-Groth, Susana; Manchado, Arturo

    2011-01-01

    The aliphatic amino acids L-alanine and L-leucine and the aromatic amino acids L-phenylalanine, L-tyrosine and L-tryptophan were irradiated in the solid state to a dose of 3.2 MGy. The degree of decomposition was measured by differential scanning calorimetry (DSC). Furthermore the degree of radioracemization was measured by optical rotatory dispersion (ORD) spectroscopy. From the DSC measurement a radiolysis rate constant k and the half life T1/2 for each amino acid have been determined and extrapolated to a dose of 14 MGy, which corresponds to the expected total dose delivered by the decay of radionuclides to the organic molecules present in comets and asteroids in 4.6×109 years, the age of the Solar System. It is shown that all the amino acids studied can survive a radiation dose of 14 MGy although they are reduced to 1/4-1/5 of their original value they had at the beginning of the history of the Solar System. Consequently, the amount of alanine or leucine found today in the meteorites known as carbonaceous chondrites is just 1/4-1/5 of the amount originally present at the epoch of the formation of the Solar System 4.6×109 years ago. Among the amino acids studied, tyrosine shows the highest radiation resistance while tryptophan does not combine its relatively high radiation resistance with an elevated level of radioracemization resistance. Apart from the exception of tryptophan, it is shown that the radiolysis rate constants k of all the amino acids studied are in reasonable agreement with the radioracemization rate constant krac.

  1. Solid state radiolysis of amino acids in an astrochemical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Cataldo, Franco, E-mail: franco.cataldo@fastwebnet.i [Istituto Nazionale di Astrofisica-Osservatorio Astrofisica di Catania, Via S. Sofia 78, 95123 Catania (Italy); Lupi Chemical Research, Via Casilina 1626/A, 00133 Rome (Italy); Angelini, Giancarlo [Istituto di Metodologie Chimiche, CNR, Via Salaria Km 29300, 00016 Monterotondo Stazione, Rome (Italy); Iglesias-Groth, Susana [Instituto de Astrofisica de Canarias, Via Lactea s/n, E-38200, La Laguna, Tenerife (Spain); Manchado, Arturo [Instituto de Astrofisica de Canarias, Via Lactea s/n, E-38200, La Laguna, Tenerife (Spain) and CSIC (Spain)

    2011-01-15

    The aliphatic amino acids L-alanine and L-leucine and the aromatic amino acids L-phenylalanine, L-tyrosine and L-tryptophan were irradiated in the solid state to a dose of 3.2 MGy. The degree of decomposition was measured by differential scanning calorimetry (DSC). Furthermore the degree of radioracemization was measured by optical rotatory dispersion (ORD) spectroscopy. From the DSC measurement a radiolysis rate constant k and the half life T{sub 1/2} for each amino acid have been determined and extrapolated to a dose of 14 MGy, which corresponds to the expected total dose delivered by the decay of radionuclides to the organic molecules present in comets and asteroids in 4.6x10{sup 9} years, the age of the Solar System. It is shown that all the amino acids studied can survive a radiation dose of 14 MGy although they are reduced to 1/4-1/5 of their original value they had at the beginning of the history of the Solar System. Consequently, the amount of alanine or leucine found today in the meteorites known as carbonaceous chondrites is just 1/4-1/5 of the amount originally present at the epoch of the formation of the Solar System 4.6x10{sup 9} years ago. Among the amino acids studied, tyrosine shows the highest radiation resistance while tryptophan does not combine its relatively high radiation resistance with an elevated level of radioracemization resistance. Apart from the exception of tryptophan, it is shown that the radiolysis rate constants k of all the amino acids studied are in reasonable agreement with the radioracemization rate constant k{sub rac}.

  2. Investigation of the n-. gamma. -radiolysis of nitrogen tetroxide under super-critical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Nesterenko, V.B.; Gvozdev, A.A.; Doroshkevich, V.N.; Nichipor, G.V.; Trubnikov, V.P. (AN Belorusskoj SSR, Minsk. Inst. Yadernoj Ehnergetiki)

    1983-01-01

    The yield of the 'irreversible' products of nitrogen tetroxide radiolysis has been determined in stainless steel ampoules in the field of the reactor mixed radiation; Radiolysis has been investigated in the range of temperatures 200 to 350 deg C, pressures 7.8 to 15.7 MPa and dose rates 48 and 162 W/kg. The measured primary yield of nitrogen atoms under nitrogen dioxide radiolysis is equal to 0.28 + 0.02 at/100 eV at 250 deg C. It is shown that in the investigated range of temperatures and pressures the yield of the 'irreversible' radiolysis products can be determined using the known kinetic data on the reactions of nitrogen atoms with molecules and assuming the primary yield of nitrogen atoms from nitrogen dioxide and nitric oxide equal to 0.28 and 4.5 at/100 eV respectively.

  3. Stability of Solvent Radiolysis in Purex Process of Spent Fuel Reprocessing

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>In Purex process the regradation of TBP-diluents due to the radiolysis may cause diffculty for the process. Three diluents such as n-dodecane, hydrogenation kerosene, special kerosene were used in Purex

  4. Mössbauer study on the gamma radiolysis of anhydrous cesium tris (oxalato) ferrate(III)

    Science.gov (United States)

    Ladriere, J.; Senterre, V.; Apers, D.

    1992-04-01

    The final product of the gamma radiolysis of anhydrous cesium tris(oxalato) ferrate(III) has been identified by Mössbauer spectroscopy as Cs2Fe(ox)2. The radiolytic decomposition proceeds as a first-order process due to the original compound depletion and to the radiolytic stability of the ferrous compound. Lamb-Mössbauer factors measurements indicate that the recoilless fractions of the iron species are practically unaffected by the radiolysis.

  5. Gamma-radiolysis of dimethyl sulfoxide. II. Radiolysis yields and possible mechanisms; Gamma-Radiolisis del dimetilsulfoxido II. Rendimientos radioloticos y posibles mecanismos

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, M. C.; Barrera, R.

    1978-07-01

    As result of quantitative studies on gamma-radiolysis of DMSO at a dose range of 90-850 Mrads, constant G values have been obtained for the following radiolysis compounds: G(-DMSO) - 6.7 {+-}0.2; G(dimethyl sulphide) - 3.4 {+-}0.3; G(methane) - 0,75 {+-} 0.04; G(dimethyl disulphide) -0.33 {+-}0,03; G(tri methylsulphonium methanesulphonate) - 0.26 {+-} 0,01; G(methyl methanethiosulphonate) - 0,25 {+-}0.02; G(dimethyl sulphona)-0.21{+-}0.02; G(H{sub 2})-0.18{+-}0.02; and G(propane)--0.0092{+-}0.0007. Initial G values have been obtained for other identified compounds: Gi(ethane)-0,46; Gi(CO)-0.052; and Gi(CO{sub 2})-0.030. Possible mechanisms on the radiolysis process are proposed. (Author) 17 refs.

  6. Spectroscopic assessment of argon gas discharge induced radiolysis of aqueous adenine and thymine

    Energy Technology Data Exchange (ETDEWEB)

    Su Xi [Key Laboratory of Ion Beam Bio-engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, P.O. Box 1138, Shushanhu Road 350, Hefei 230031 (China); Huang Qing, E-mail: huangq@ipp.ac.cn [Key Laboratory of Ion Beam Bio-engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, P.O. Box 1138, Shushanhu Road 350, Hefei 230031 (China); Dang Bingrong [Institute of Modern Physics, Chinese Academy of Sciences, 509 Nanchang Road, Lanzhou 730000 (China); Wang Xiangqin; Yu Zengliang [Key Laboratory of Ion Beam Bio-engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, P.O. Box 1138, Shushanhu Road 350, Hefei 230031 (China)

    2011-12-15

    Ionizing radiation influences life profoundly for it can modify genetic materials. It is a long-standing task to investigate the interaction between energetic particles and DNA together with its components such as nucleotides, nucleosides and bases so as to predict and assess the potential biological effects. In this study, argon gas discharge was employed to produce energetic ions and electrons. The gas discharge caused the radiolysis of aqueous bases and the involved reactions were analyzed by means of spectroscopic tools including UV-vis absorption, fluorescence and Fourier transformation infrared (FTIR) spectroscopy, also assisted by liquid chromatography/mass spectrometry (LC/MS). It was found that the discharge resulted in the adenine-derived lesions such as 4,6-diamino-5-formamidopyrimidine, 8-OH-Ade and 2-OH-Ade in the radiolysis of aqueous adenine, as well as the thymine-derived lesions such as thymine glycol, 5-hydroxy-6-hydrothymine and/or 6-hydroxy-5-hydrothymine, 5-hydroxymethyluracil and 5-formyluracil in the radiolysis of aqueous thymine. The study of radio-sensitivity showed that adenine was more resistant to the discharge. The mechanisms of the involved reactions were studied in detail, confirming that the hydroxyl radical played a dominant role. - Highlights: > Effective new way to study radiolysis of bases via a home-made argon discharge apparatus. > Quantitative analysis of base radiolysis employing spectroscopic tools combined with HPLC/MS. > Discovery of different radiolysis effect compared with other forms of ionizing radiations.

  7. Density dependence of the yield of hydrated electrons in the low-LET radiolysis of supercritical water at 400 °C: influence of the geminate recombination of subexcitation-energy electrons prior to thermalization.

    Science.gov (United States)

    Meesungnoen, Jintana; Sanguanmith, Sunuchakan; Jay-Gerin, Jean-Paul

    2013-10-21

    Monte Carlo simulations were used to calculate the yield of hydrated electrons (eaq(-)) in the low-linear energy transfer radiolysis of supercritical water at 400 °C as a function of water density over the range of ~0.15 to 0.6 g cm(-3). Very good agreement was found between our calculations and picosecond pulse radiolysis experimental data at ~60 ps and 1 ns at high density (>0.35 g cm(-3)). At densities lower than ~0.35 g cm(-3), our eaq(-) yields were lower than the experimental data, especially at ~60 ps. However, if we incorporated into the simulations a prompt geminate electron-cation (H2O˙(+)) recombination (prior thermalization of the electron) that decreased as the density decreased, our computed eaq(-) yields at ~60 ps and 1 ns compared fairly well with the experimental data for the entire density range studied.

  8. Conditions for critical effects in the mass action kinetics equations for water radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Wittman, Richard S.; Buck, Edgar C.; Mausolf, Edward J.; McNamara, Bruce K.; Smith, Frances N.; Soderquist, Chuck Z.

    2014-12-26

    We report on a subtle global feature of the mass action kinetics equations for water radiolysis that results in predictions of a critical behavior in H2O2 and associated radical concentrations. While radiolysis kinetics has been studied extensively in the past, it is only in recent years that high speed computing has allowed the rapid exploration of the solution over widely varying dose and compositional conditions. We explore the radiolytic production of H2O2 under various externally fixed conditions of molecular H2 and O2 that have been regarded as problematic in the literature – specifically, “jumps” in predicted concentrations, and inconsistencies between predictions and experiments have been reported for alpha radiolysis. We computationally map-out a critical concentration behavior for alpha radiolysis kinetics using a comprehensive set of reactions. We then show that all features of interest are accurately reproduced with 15 reactions. An analytical solution for steady-state concentrations of the 15 reactions reveals regions in [H2] and [O2] where the H2O2 concentration is not unique – both stable and unstable concentrations exist. The boundary of this region can be characterized analytically as a function of G-values and rate constants independent of dose rate. Physically, the boundary can be understood as separating a region where a steady-state H2O2 concentration exists, from one where it does not exist without a direct decomposition reaction. We show that this behavior is consistent with reported alpha radiolysis data and that no such behavior should occur for gamma radiolysis. We suggest experiments that could verify or discredit a critical concentration behavior for alpha radiolysis and could place more restrictive ranges on G-values from derived relationships between them.

  9. Conditions for critical effects in the mass action kinetics equations for water radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Wittman, Richard S.; Buck, Edgar C.; Mausolf, Edward J.; McNamara, Bruce K.; Smith, Frances N.; Soderquist, Chuck Z.

    2014-11-25

    We report on a subtle global feature of the mass action kinetics equations for water radiolysis that results in predictions of a critical behavior in H2O2 and associated radical concentrations. While radiolysis kinetics has been studied extensively in the past, it is only in recent years that high speed computing has allowed the rapid exploration of the solution over widely varying dose and compositional conditions. We explore the radiolytic production of H2O2 under various externally fixed conditions of molecular H2 and O2 that have been regarded as problematic in the literature – specifically, “jumps” in predicted concentrations, and inconsistencies between predictions and experiments have been reported for alpha radiolysis. We computationally map-out a critical concentration behavior for alpha radiolysis kinetics using a comprehensive set of reactions. We then show that all features of interest are accurately reproduced with 15 reactions. An analytical solution for steady-state concentrations of the 15 reactions reveals regions in [H2] and [O2] where the H2O2 concentration is not unique – both stable and unstable concentrations exist. The boundary of this region can be characterized analytically as a function of G-values and rate constants independent of dose rate. Physically, the boundary can be understood as separating a region where a steady-state H2O2 concentration exists, from one where it does not exist without a direct decomposition reaction. We show that this behavior is consistent with reported alpha radiolysis data and that no such behavior should occur for gamma radiolysis. We suggest experiments that could verify or discredit a critical concentration behavior for alpha radiolysis and could place more restrictive ranges on G-values from derived relationships between them.

  10. Heterogeneous radiolysis of HCN adsorbed on a solid surface

    Energy Technology Data Exchange (ETDEWEB)

    Colin-Garcia, M.; Ortega-Gutierrez, F. [Instituto de Geologia, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico D.F. (Mexico); Ramos-Bernal, S. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico D.F. (Mexico); Negron-Mendoza, A., E-mail: negron@nucleares.unam.m [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico D.F. (Mexico)

    2010-07-21

    Hydrogen cyanide is a key molecule for chemical evolution studies because, when it is exposed to different sources of energy, it forms various compounds of biological importance. To understand the role of minerals in chemical evolution, a series of experiments was performed. First, the adsorption capacity of HCN on different surface minerals was studied; the results show that HCN is readily adsorbed onto the solids proposed (zeolite, serpentine, dolomite, and sodium montmorillonite), in particular zeolite and montmorillonite. Second, the radiolysis of HCN adsorbed on olivine (as an example of a mineral surface) was also followed; it was found that the rate of HCN decomposition by gamma irradiation is enhanced in the presence of the solid. The third series of studies show that organic material was produced in high abundance from HCN at high radiation doses. The radiolytic products included gases (CO{sub 2}, NH{sub 4}, and CO) and oligomeric materials that release carboxylic acids (succinic, malonic, citric, and tricarballylic acids) and amino acids upon acid hydrolysis. These experiments suggest that minerals could have participated actively in chemical evolution processes.

  11. Radiolysis and hydrolysis of magnetically assisted chemical separation particles

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, B.A.; Nunez, L.; Vandegrift, G.F.

    1995-05-01

    The magnetically assisted chemical separation (MACS) process is designed to separate transuranic (TRU) elements out of high-level waste (HLW) or TRU waste. Magnetic microparticles (1--25 {mu}m) were coated with octyl (phenyl)N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) dissolved in tributyl phosphate (TBP) and tested for removing TRU elements from acidic nitrate solutions. The particles were contacted with nitric acid solutions and Hanford plutonium finishing plant (PFP) simulant, irradiated with a high intensity {sup 60}Co {gamma}-ray source, and evaluated for effectiveness in removing TRU elements from 2m HNO{sub 3} solutions. The resistance of the coatings and magnetic cores to radiolytic damage and hydrolytic degradation was investigated by irradiating samples of particles suspended in a variety of solutions with doses of up to 5 Mrad. Transmission electron microscopy (TEM), magnetic susceptibility measurements, and physical observations of the particles and suspension solutions were used to assess physical changes to the particles. Processes that affect the surface of the particles dramatically alter the binding sites for TRU in solution. Hydrolysis played a larger role than radiolysis in the degradation of the extraction capacity of the particles.

  12. Pulse radiolysis study on the mechanisms of reactions of CCl3OO

    Institute of Scientific and Technical Information of China (English)

    MIAO; Jinling

    2001-01-01

    Chitosans with various degrees of deacetylation (D.D.), which were used as standard sample for FTIR determination, were prepared from completely deacetylated chitosan by homogeneous N-acetylation reaction. By combining four probable probe bands, i.e. 1655, 1560, 1380 and 1320 cm-1, eight probable reference bands, i.e. 3430, 2920, 2880, 1425, 1155, 1070, 1030 and 895 cm-1 and two baseline methods, the most suitable ratios Aprobe band/Areference band from IR spectra to determine the degree of acetylation of chitosan were evaluated from 48 combinations to be A1560/A2880, A1560/A2920 and A1655/A3430(A1560/A2880 is mostly recommended). The second baseline method, i.e. linking between adjacent two valleys, was better for measuring the absorbances of 1560 and 1655 cm-1 bands. The determination range of the D.D. (1%-100%) covered almost the whole range. The standard curves with A1560/A2880 and A1655/A3430 were also suitable for the determination of degree of substitution of other N-acylated chitosan, such as N-propionyl chitosan, N-butyryl chitosan and N-hexanoyl chitosan.

  13. Pulse radiolysis of solutions of stilbene. 2. Ionic and free radical species in benzene and cyclohexane

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, E.A.; Salmon, G.A.

    1978-02-23

    The spectra of the radical cation and anion of trans-stilbene in benzene and cyclohexane have been resolved using various electron and positive charge scavengers. The decay of the ions is second order in both solvents. In cyclohexane only part of the yield of solvent cations is scavengeable by trans-stilbene; in benzene the stilbene cation is converted to the dimer in the presence of high stilbene concentrations. The electron scavengers N/sub 2/O and c-C/sub 6/F/sub 12/ compete directly with trans-stilbene for electrons and we deduce rate constants for the reactions of electrons with c-C/sub 6/F/sub 12/ and trans-stilbene of (1.2 +- 0.6) x 10/sup 12/ and (0.72 +- 0.5) x 10/sup 12/ M/sup -1/ s/sup -1/, respectively. SF/sub 6/ reduces the yield of trans-stilbene anion more efficiently than can be attributed solely to electron scavenging and it is shown that electron transfer from trans-stilbene anion to SF/sub 6/ occurs at a rate constant, k/sub 4/ = (3.9 +- 0.4) x 10/sup 9/ M/sup -1/ s/sup -1/. The presence of either aniline or n-butylamine causes enhancement of the yield of stilbene anion, the effect being particularly marked in the case of aniline. Possible explanations of the effect are considered. It is proposed that the UV absorptions are due to radical species, which in cyclohexane solution are most probably formed by the addition of cyclohexyl radicals to the olefinic double bond of the stilbenes.

  14. Reactions of OH Radicals with Tris (1,10-Phenanthroline) Iron (II) Studied by Pulse Radiolysis

    DEFF Research Database (Denmark)

    Siekierska Floryan, E.; Pagsberg, Palle Bjørn

    1976-01-01

    The reaction of OH radicals with aqueous tris(1,10-phenanthroline)iron(II) leads to the formation of an adduct, which exhibits a broad absorption band at rmpH = 6, λmax = 460 nm, and epsilon (Porson)460 = 6700 (molar, decadic, 1 mol−1 cm−1). The rate of formation of the adduct is first order in c...

  15. Hydrogen-Atom Attack on Methyl Viologen in Aqueous Solution Studied by Pulse Radiolysis

    DEFF Research Database (Denmark)

    Solar, S.; Solar, W.; Getoff, N.;

    1984-01-01

    Using hydrogen at high pressures of up to 150 bar (0.12 mol dm–3 H2) as an OH scavenger in aqueous MV2+ solutions (pH 1) it is possible to differentiate between two kinds of transient formed simultaneously by H-atom attack on methyl viologen. One of them is assigned to an H adduct on the N atom, ...

  16. Kinetics study of the solvated electron decay in THF using laser-synchronised picosecond electron pulse

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Picosecond pulse radiolysis of neat tetrahydrofuran (THF) shows a fast decay of the solvated electron within 2.5ns. The decay of the solvated electron observed at 790nm is because of spur reaction. A numerical simulation using time dependent Smoluchowski equation containing a sink term with a distance dependent reaction rate is used to fit the pulse-probe data and shows that the geminate reaction can proceed at long distance in this low polar solvent.

  17. Gamma radiolysis of the highly selective ligands CyMe{sub 4}BTBP and CyMe{sub 4}BTPhen: Qualitative and quantitative investigation of radiolysis product

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H.; Wilden, A.; Modolo, G.; Bosbach, D. [Forschungszentrum Juelich GmbH, Institute of Energy and Climate Research IEK-6: Nuclear Waste Management, 52425 Juelich (Germany); Santiago-Schuebel, B.; Hupert, M. [Forschungszentrum Juelich GmbH, Central Institute for Engineering, Analytics - ZEA-3, 52425 Juelich (Germany); Svehla, J.; Gruner, B. [Institute of Inorganic Chemistry, Academy of Sciences, Hlavni 1001, 25068 Husinec-Rez (Czech Republic); Ekberg, C. [Department of Chemical and Biochemical Engineering, Chalmers University of Technology, 41296 Gothenburg (Sweden)

    2016-07-01

    The highly selective nitrogen donor ligands CyMe{sub 4}BTBP and CyMe4{sub B}TPhen where γ-irradiated under identical experimental conditions in 1-octanol with and without contact to nitric acid solution. Subsequently, solvent extraction experiments were carried out to evaluate the stability of the extractants against γ-radiation monitoring Am(III) and Eu(III) distribution ratios. Generally, decreasing distribution ratios with increasing absorbed dose were detected for both molecules. Furthermore, qualitative mass spectrometric analyses were performed and ligand concentrations were determined by HPLC-DAD after irradiation to investigate the radiolysis mechanism. An exponential decrease with increasing absorbed dose was observed for both ligands with a faster rate for CyMe{sub 4}BTPhen. Main radiolysis products indicated the addition of one or more diluent molecules (1-octanol) to the ligand via prior production of α-hydroxy-octyl radicals from diluent radiolysis. The addition of nitric acid during the irradiation lead to a remarkable stabilization of the system, as the extraction of Am(III) and Eu(III) did not change significantly over the whole examined dose range. Quantification of the remaining ligand concentration on the other hand showed decreasing concentrations with increasing absorbed dose. The stabilization of D values is therefore explained by the formation of 1-octanol addition products which are also able to extract the studied metal ions. (authors)

  18. Radiolysis and defect structure in electron-irradiated α-quartz

    OpenAIRE

    Hobbs, L.; Pascucci, M.

    1980-01-01

    The defect microstructure of electron-irradiated α-quartz was studied by transmission electron microscopy. Formation of heterogeneously-nucleated disordered strain centers and a homogeneous crystalline → amorphous transformation of the surrounding matrix were observed. Both features are shown to be attributable to radiolysis, a mechanism for which is proposed.

  19. Radiolysis and corrosion of 238Pu-doped UO2 pellets in chloride brine

    Indian Academy of Sciences (India)

    M Kelm; E Bohnert

    2002-12-01

    Deaerated 5 M NaCl solution is irradiated in the presence of UO2 pellets with a-radiation from 238Pu. Experiments are conducted with 238Pu doped pellets and others with 238Pu dissolved in the brine. The radiolysis products and yields of mobilized U and Pu from the oxidative dissolution of UO2 are determined. Results found for radiolysis products and for the oxidation/dissolution of pellets immersed in Pu containing brine are similar to results for Pu doped pellets, where the radiation chemical processes occur only in the liquid layer of some 10 m thickness adjacent to the pellet. The yield of radiolysis products is comparable to earlier results, that of mobilized U from the pellets is < 1% of the total amount of oxidized species. Thus, the radiation chemical yield (-value) for mobilized hexavalent U is < 0.01 ions/100 eV. In spite of the low radiation yield for the corrosion, the rate of UO2 dissolution is higher than expected for the concentrations of long-lived oxidizing radiolysis compounds found in the solutions.

  20. Pulse radiolytic studies of electron transfer processes and applications to solar photochemistry. Progress report, [March 1992--March 1993

    Energy Technology Data Exchange (ETDEWEB)

    Neta, P.

    1993-04-01

    Electron transfer and other reactions of various short-lived intermediates have been studied by pulse radiolysis and laser flash photolysis. Highlights of results during the past year are summarized under two main sections: Metalloporphyrin electron transfer and associated reactions, and solvent effects on reactions of inorganic radicals and organic peroxyl radicals.

  1. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality...... a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, an anthropomorfized archive of a past intimacy and an all-encompassing immersive environment modulating continuously in real space-time....

  2. Study of the consequences of secondary water radiolysis within and surrounding a defective canister

    Energy Technology Data Exchange (ETDEWEB)

    Jinsong Liu; Neretnieks, I. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Chemical Engineering and Technology; Stroemberg, Bo [Swedish Nuclear Power Inspectorate, Stockholm (Sweden)

    2000-11-01

    Consequences of secondary water radiolysis, caused by dispersed radionuclides released from spent nuclear fuel, both inside a defective canister and in the bentonite buffer surrounding the canister have been studied. The dissolution rate of the spent fuel is assumed to be controlled by chemical kinetics. Several cases have been addressed. First a simple mass balance model is presented. Some very conservative assumptions like complete failure of the canister one thousand years after its deposition in the repository and instantaneous oxidation rate of the spent fuel are deliberately made, to explore the upper bound limit of the effect of the secondary water radiolysis on the spent fuel dissolution. The model results show that the spent fuel could possibly be oxidised in an ever-increasing rate with these very simplified assumptions. More realistic and less conservative cases are then considered. In these cases, the canister is assumed to be initially defective with a hole of a few millimeters on its wall. The small hole will considerably restrict the transport of oxidants through the canister wall and the release of radionuclides to the outside of the canister. The spent fuel dissolution is assumed to be controlled by chemical kinetics at rates extrapolated from experimental studies. The cases are modelled with progressive complication. In the first case the effect of the secondary radiolysis inside fuel canister is neglected. It is also assumed that secondary phases of radionuclides do not precipitate inside the canister. The model results show that a relatively large domain of the near-field can be oxidised by the oxidants of secondary radiolysis. In the second case it is assumed that the radionuclide concentration within the canister is controlled by its respective solubility limit. The amount of radionuclides released out of the canister will then be limited by the solubility of the secondary phases. The effect of the secondary radiolysis will be quite limited in

  3. Summary Report on Gamma Radiolysis of TBP/n-dodecane in the Presence of Nitric Acid Using the Radiolysis/Hydrolysis Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Dean R. Peterman; Bruce J. Mincher; Catherine L. Riddle; Richard D. Tillotson

    2010-08-01

    Design and installation has been completed for a state-of-the-art radiolysis/hydrolysis test loop system. The system is used to evaluate the effects of gamma radiolysis and acid hydrolysis on the stability and performance of solvent extraction process solvents. The test loop is comprised of two main sections; the solvent irradiation and hydrolysis loop and the solvent reconditioning loop. In the solvent irradiation and hydrolysis loop, aqueous and organic phases are mixed and circulated through a gamma irradiator until the desired absorbed dose is achieved. Irradiation of the mixed phases is more representative of actual conditions in a solvent extraction process. Additionally, the contact of the organic phase with the aqueous phase will subject the solvent components to hydrolysis. This hydrolysis can be accelerated by controlling the system at an elevated temperature. At defined intervals, the organic from the irradiation/hydrolysis loop will be transferred to the solvent reconditioning loop where the solvent is contacted with scrub, strip, and solvent wash solutions which simulate process flowsheet conditions. These two processes are repeated until the total desired dose is achieved. Since all viable solvent extraction components in an advanced fuel cycle must exhibit high radiolytic and hydrolytic stability, this test loop is not limited to any one solvent system but is applicable to all systems of interest. Also, the test loop is not limited to testing of process flowsheets. It is also a valuable tool in support of fundamental research on newly identified extractants/modifiers and the impact of gamma radiation on their stability in a dynamic environment. The investigation of the radiolysis of a TBP/n-dodecane process solvent in contact with aqueous nitric acid has been performed. These studies were intended to confirm/optimize the operability of the test loop system. Additionally, these data are directly applicable to numerous other solvent extraction

  4. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality......“Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... of the visitor’s beating heart to the blink of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the blinking light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant...

  5. Muon radiolysis affected by density inhomogeneity in near-critical fluids.

    Science.gov (United States)

    Cormier, P J; Alcorn, C; Legate, G; Ghandi, K

    2014-04-01

    In this article we show the significant tunability of radiation chemistry in supercritical ethane and to a lesser extent in near critical CO2. The information was obtained by studies of muonium (Mu = μ(+)e(-)), which is formed by the thermalization of positive muons in different materials. The studies of the proportions of three fractions of muon polarization, PMu, diamagnetic PD and lost fraction, PL provided the information on radiolysis processes involved in muon thermalization. Our studies include three different supercritical fluids, water, ethane and carbon dioxide. A combination of mobile electrons and other radiolysis products such as (•)C2H5 contribute to interesting behavior at densities ∼40% above the critical point in ethane. In carbon dioxide, an increase in electron mobility contributes to the lost fraction. The hydrated electron in water is responsible for the lost fraction and decreases the muonium fraction.

  6. Effect of Groundwater Radiolysis on the Wall—rock Alteration of Uranium Ore Deposits

    Institute of Scientific and Technical Information of China (English)

    闵茂中; 吴俊奇; 等

    1994-01-01

    Reported for the first time in this paper are the results of simulating experiments on the γ-irradiation-induced oxidation of Fe2+ under the physicochemical conditions(T=200℃,P=50MPa,Eh=-0.1V,pH=7.2)simial to those under which moderate-low temperature hydrothermal uranium deposits are formed.Evdence shows that the effect of groundwater radiolysis seems to be the major mechanism of wall-rock alteration(hematitizaton)of hydrothermal uranium deposits.Moreover,adiscussion was made of possible effects of radiolysis of the water-rock system on wall-rock alterations including argillization and decoloration of uranium ore deposits on the basis of the experimental results.

  7. Radiolysis as a solution for accelerated ageing studies of electrolytes in Lithium-ion batteries

    Science.gov (United States)

    Ortiz, Daniel; Steinmetz, Vincent; Durand, Delphine; Legand, Solène; Dauvois, Vincent; Maître, Philippe; Le Caër, Sophie

    2015-04-01

    Diethyl carbonate and dimethyl carbonate are prototype examples of eco-friendly solvents used in lithium-ion batteries. Nevertheless, their degradation products affect both the battery performance and its safety. Therefore, it is of paramount importance to understand the reaction mechanisms involved in the ageing processes. Among those, redox processes are likely to play a critical role. Here we show that radiolysis is an ideal tool to generate the electrolytes degradation products. The major gases detected after irradiation (H2, CH4, C2H6, CO and CO2) are identified and quantified. Moreover, the chemical compounds formed in the liquid phase are characterized by different mass spectrometry techniques. Reaction mechanisms are then proposed. The detected products are consistent with those of the cycling of Li-based cells. This demonstrates that radiolysis is a versatile and very helpful tool to better understand the phenomena occurring in lithium-ion batteries.

  8. EVIDENCE OF CORROSIVE GAS FORMED BY RADIOLYSIS OF CHLORIDE SALTS IN PLUTONIUM-BEARING MATERIALS

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, K.; Louthan, M.

    2010-02-01

    Corrosion and pitting have been observed in headspace regions of stainless steel containers enclosing plutonium oxide/salt mixtures. These observations are consistent with the formation of a corrosive gas, probably HCl, and transport of that gas to the headspace regions of sealed containers. The NH{sub 4}Cl films found on the walls of the sealed containers is also indicative of the presence of HCl gas. Radiolysis of hydrated alkaline earth salts is the probable source of HCl.

  9. The radiolysis of CMPO: effects of acid, metal complexation and alpha vs. gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bruce J. Mincher; Stephen P. Mezyk; Gary S. Groenewold

    2016-05-01

    Abstract The group actinide/lanthanide complexing agent octylphenylcarbamoylmethyl phosphine oxide (CMPO) has been examined for its radiation stability by measuring the kinetics of its reactions with free radicals in both the aqueous and organic phases for the free and metal-complexed ligand, identifying its degradation products for both alpha and gamma irradiation, measuring the effects on solvent extraction performance, and measuring the G-values for its degradation under various conditions. This includes the G-values for CMPO in the absence of, and in contact with the acidic aqueous phase, where it is shown that the acidic aqueous phase provides radio-protection for this ligand. It was found that both solvent and metal complexation affect the kinetics of the reaction of the •NO3 radical, a product of HNO3 radiolysis, with CMPO. For example, CMPO complexed with lanthanides has a rate constant for this reaction an order of magnitude higher than for the free ligand, and the reaction for the free ligand in the organic phase is about three times faster than in the aqueous phase. In steady state radiolysis kinetics it was determined that HNO3, although not NO3- anion, provides radio-protection to CMPO, with the G-value for its degradation decreasing with increasing acidity, until it was almost completely suppressed by irradiation in contact with 5 M HNO3. The same degradation products were produced by irradiation with alpha and gamma-sources, except that the relative abundances of these products varied. For example, the product of C-C bond scission was produced only in low amounts for gamma-radiolysis, but it was an important product for samples irradiated with a He ion beam. These results are compared to the new data appearing in the literature on DGA radiolysis, since CMPO and the DGAs both contain the amide functional group.

  10. Accelerated Monte Carlo simulation on the chemical stage in water radiolysis using GPU

    Science.gov (United States)

    Tian, Zhen; Jiang, Steve B.; Jia, Xun

    2017-04-01

    The accurate simulation of water radiolysis is an important step to understand the mechanisms of radiobiology and quantitatively test some hypotheses regarding radiobiological effects. However, the simulation of water radiolysis is highly time consuming, taking hours or even days to be completed by a conventional CPU processor. This time limitation hinders cell-level simulations for a number of research studies. We recently initiated efforts to develop gMicroMC, a GPU-based fast microscopic MC simulation package for water radiolysis. The first step of this project focused on accelerating the simulation of the chemical stage, the most time consuming stage in the entire water radiolysis process. A GPU-friendly parallelization strategy was designed to address the highly correlated many-body simulation problem caused by the mutual competitive chemical reactions between the radiolytic molecules. Two cases were tested, using a 750 keV electron and a 5 MeV proton incident in pure water, respectively. The time-dependent yields of all the radiolytic species during the chemical stage were used to evaluate the accuracy of the simulation. The relative differences between our simulation and the Geant4-DNA simulation were on average 5.3% and 4.4% for the two cases. Our package, executed on an Nvidia Titan black GPU card, successfully completed the chemical stage simulation of the two cases within 599.2 s and 489.0 s. As compared with Geant4-DNA that was executed on an Intel i7-5500U CPU processor and needed 28.6 h and 26.8 h for the two cases using a single CPU core, our package achieved a speed-up factor of 171.1-197.2.

  11. Effect of water radiolysis and complexing species on the leaching of zirconolite

    Energy Technology Data Exchange (ETDEWEB)

    Tribet, M. [Institut de Physique Nucleaire de Lyon (IPNL), Universite de Lyon, Universite Lyon1, CNRS/IN2P3, 4 Rue E. Fermi, 69622 Villeurbanne cedex (France); CEA/DEN/DTCD.SECM/LMPA, Marcoule, BP 17171, 30207 Bagnols sur Ceze cedex (France); Toulhoat, N. [CEA/DEN/Saclay, 91191 Gif sur Yvette cedex (France); Institut de Physique Nucleaire de Lyon (IPNL), Universite de Lyon, Universite Lyon1, CNRS/IN2P3, 4 Rue E. Fermi, 69622 Villeurbanne cedex (France); Moncoffre, N. [Institut de Physique Nucleaire de Lyon (IPNL), Universite de Lyon, Universite Lyon1, CNRS/IN2P3, 4 Rue E. Fermi, 69622 Villeurbanne cedex (France); Jegou, C.; Leturcq, G. [CEA/DEN/DTCD.SECM/LMPA, Marcoule, BP 17171, 30207 Bagnols sur Ceze cedex (France); Corbel, C. [CEA/DSM/DRECAM/LSI, Ecole Polytechnique, 91 128 Palaiseau (France); Toulhoat, P. [Universite de Lyon, Universite Lyon1, CNRS/ISA, UFR de Chimie Biochimie, 69622 Villeurbanne cedex (France); INERIS, Parc Technologique Alata, BP2 F-60550 Verneuil en Halatte (France)

    2008-07-01

    Zirconolite is one of the matrices considered for the confinement of minor actinides in case of deep geological disposal. Its chemical durability has been studied during dissolution under charged particle-induced water radiolysis (He{sup 2+} and proton external beams) to identify possible effects on dissolution rates and mechanisms. Two experimental geometries have been used to assess the influence of the solid irradiation on one hand and the total deposited energy into water on the other hand. These irradiations have been performed on polycrystalline zirconolite (Ca{sub 0.8}Nd{sub 0.2}ZrTi{sub 1.8}Al{sub 0.2}O{sub 7}) in pure water or in presence of complexing ions such as F{sup -}. The sample dissolution has been monitored through the release of cations. Under radiolysis, an increase in the Zr, Ti and Nd releases of one order of magnitude has been observed compared to results obtained without radiolysis. The presence of complexing species has induced an additional increase of two orders of magnitude in the Ti and Zr releases. (authors)

  12. Influence of alpha and gamma radiolysis on Pu retention in the solvent TBP/kerosene

    Directory of Open Access Journals (Sweden)

    Gao Yang

    2014-12-01

    Full Text Available In light of the issue of radiolysis of the solvent system in PUREX process, alpha and gamma radiation stability of tributyl phosphate (TBP/kerosene (OK have been studied in this paper, in which 238Pu dissolved in the organic phase and 60Co are selected as alpha and gamma irradiation sources, respectively. The amount of the degradation products not easily removed after the washing process has been measured by the plutonium retention. The effects of the absorbed dose, the TBP volume fraction, the cumulative absorbed dose and the presence of UO2 2+ and Zr4+ on the radiolysis of the solvents have been investigated. The results have indicated that the Pu retention increases with the increase of the absorbed dose after alpha or gamma irradiation, and is larger for the solvent containing less TBP. There is competition between UO2 2+ and Pu4+ to complex with the degradation products, and Zr4+ accelerates the radiolysis of the system.

  13. The influence of iron on water radiolysis in cement-based materials

    Energy Technology Data Exchange (ETDEWEB)

    Bouniol, P., E-mail: pascal.bouniol@cea.f [CEA, DEN, DPC, SCCME, Laboratoire d' Etude du Comportement des Betons et des Argiles, F-91991 Gif-Sur-Yvette (France)

    2010-08-15

    For the time being, assessing the H{sub 2} source term generated by {gamma} irradiated cement-based materials consists of simulating the radiolysis of the pore liquid on the only elementary reactions relating to the decomposition of alkaline water. Such incomplete description does not take into account the impurities contained in the cement and leads to underestimate the production of H{sub 2}. Systematically present in cement materials, iron is likely to influence radiolysis by the disturbance induced on radical chemistry throughout the irradiation period. The faster reactivity of e{sub aq}{sup -} and OH{sup {center_dot}} radicals on Fe(III) and Fe(II), respectively, than on H{sub 2}O{sub 2} and H{sub 2} is responsible for the lower recycling capability of the 'Allen's chain reaction', allowing for H{sub 2} to be preserved in a closed system. A critical review of reaction data about iron complexes (hydroxo-, peroxo-) is presented in order to build up an 'iron' database. Radiolysis simulations in cement porewater in the presence of Fe(OH){sub 3} (considered as a model phase) show, as expected, an increase in the effective production of radiolytic H{sub 2} and the co-existence of exotic valence Fe(IV) with Fe(II) and (III) during the irradiation period ({gamma}).

  14. Alternative Energy: Production of H2 by Radiolysis of Water in the Rocky Cores of Icy Bodies

    Science.gov (United States)

    Bouquet, Alexis; Glein, Christopher R.; Wyrick, Danielle; Waite, J. Hunter

    2017-05-01

    We applied a model of radiolysis in earthly rock-water mixtures to several known or suspected ocean worlds: Enceladus, Ceres, Europa, Titania, Oberon, Pluto, and Charon. In this model, radiation emitted by the long-lived radionuclides (40K, 232Th, 235U, and 238U) contained in the ordinary chondrite-like rocks is partly absorbed by the water permeating the material of each body’s core. The physical and chemical processes that follow release molecular hydrogen (H2), which is a molecule of astrobiological interest. We compared the calculated production of H2 by radiolysis in each body’s core to published estimates of production by serpentinization. This study presents production calculations over 4.5 Gyr for several values of rock porosity. We found that radiolysis can produce H2 quantities equivalent to a few percent of what is estimated from serpentinization. Higher porosity, which is unlikely at the scale of a body’s entire core but possible just under the seafloor, can increase radiolytic production by almost an order of magnitude. The products of water radiolysis also include several oxidants, allowing for production of life-sustaining sulfates. Though previously unrecognized in this capacity, radiolysis in an ocean world’s outer core could be a fundamental agent in generating the chemical energy that could support life.

  15. Identification of tetraphenylborate radiolysis products in a simulated feedstock for radioactive waste processing

    Energy Technology Data Exchange (ETDEWEB)

    Eibling, R.E. [Westinghouse Savannah River Co., Aiken, SC (United States); Bartlett, M.G.; Carlson, R.E.; Testino, S.A. Jr.; Kunkel, G.J.; Browner, R.F.; Busch, K.L. [Georgia Inst. of Tech., Atlanta, GA (United States). School of Chemistry and Biochemistry

    1994-10-01

    The first step towards immobilization of the soluble radioactive species in borosilicate glass is the addition of sodium tetraphenylborate (TPB) and sodium titanate to the radioactive aqueous solution. Initial studies of the TPB hydrolysis process have found that some component of the radiolysis mixture inactivates the Cu catalyst. The interaction of organic materials with the catalyst, and the subsequent interference with the hydrolysis process, would have presented problems with the use of the vitrification process. Prevention of the catalyst deactivation is obtained by washing the irradiated TPB precipitate in the Late Wash Facility prior to hydrolysis to remove the soluble radiolysis products. Identification of the organic radiolysis products, their distribution in the Late Wash Facility, and their interactions with the Cu catalyst has become an important analytical issue. To further investigate the reaction products of the TPB precipitation process, a simulated feedstock was created from compounds known to be present in the starting materials. This simulated feedstock was precipitated with sodium TPB and then exposed to Co-60 gamma radiation to simulate two years of additional storage time prior to the hydrolysis process. The irradiated product was divided into two parts, the filtered supernatant liquid and the precipitate slurry, which contains the TPB and the solid sodium titanate. Using gas chromatography/mass spectrometry, liquid secondary ion mass spectrometry, inductively coupled plasma/mass spectrometry, ion chromatography, and high performance liquid chromatography, over 50 organic and inorganic species have been identified in the aqueous portion of a simulated feedstock for TPB hydrolysis. The major organic species present are benzene, phenol, benzamide and a variety of substituted phenylphenols. The major inorganic species present are sodium, nitrite, and oxalate ions.

  16. A Potential Mechanism for Perchlorate Formation on Mars: Surface-Radiolysis-Initiated Atmospheric Chemistry

    Science.gov (United States)

    Wilson, Eric; Atreya, Sushil K.; Kaiser, Ralf-Ingo; Mahaffy, Paul

    2016-10-01

    Perchlorate (ClO4-) is prevalent on Earth, and with observations of perchlorate on lunar samples and chondrite meteorites, along with recent observations indicating the presence of perchlorate (ClO4-) in the Martian surface by the Phoenix lander and the Sample Analysis at Mars (SAM) on the Mars Science Laboratory (MSL) rover, it appears that the existence of perchlorate is widespread throughout the solar system. However, the abundance and isotopic composition of Martian perchlorate suggest that the perchlorate formation mechanism on Mars may involve a different path than perchlorate found elsewhere in the solar system. Motivated by this, we employ a one-dimensional chemical model to investigate the viability of perchlorate formation in the atmosphere of Mars, instigated by the radiolysis of the Martian surface by galactic cosmic rays. The surface-atmosphere interaction to produce Martian perchlorate involves the sublimation of chlorine oxides into the atmosphere, through surface radiolysis, and their subsequent synthesis to form perchloric acid (HClO4), followed by surface deposition and mineralization to form surface perchlorates. Considering the chlorine oxide, OClO, we find an OClO surface flux as low as 3.2x107 molecules cm-2 s-1, sublimated into the atmosphere from the surface could produce sufficient HClO4 to explain the perchlorate concentration on Mars, assuming an accumulation depth of 30 cm and integrated over the Amazonian period. Radiolysis provides an efficient pathway for the oxidation of chlorine, bypassing the efficient Cl/HCl recycling mechanism that characterizes HClO4 formation mechanisms proposed for the Earth but not Mars.

  17. A Review of Radiolysis Concerns for Water Shielding in Fission Surface Power Applications

    Science.gov (United States)

    Schoenfeld, Michael P.

    2008-01-01

    This paper presents an overview of radiolysis concerns with regard to water shields for fission surface power. A review of the radiolysis process is presented and key parameters and trends are identified. From this understanding of the radiolytic decomposition of water, shield pressurization and corrosion are identified as the primary concerns. Existing experimental and modeling data addressing concerns are summarized. It was found that radiolysis of pure water in a closed volume results in minimal, if any net decomposition, and therefore reduces the potential for shield pressurization and corrosion. With the space program focus m emphasize more on permanent return to the Moon and eventually manned exploration of Mars, there has been a renewed look at fission power to meet the difficult technical & design challenges associated with this effort. This is due to the ability of fission power to provide a power rich environment that is insensitive to solar intensity and related aspects such as duration of night, dusty environments, and distance from the sun, etc. One critical aspect in the utilization of fission power for these applications of manned exploration is shielding. Although not typically considered for space applications, water shields have been identified as one potential option due to benefits in mass savings and reduced development cost and technical risk (Poston, 2006). However, the water shield option requires demonstration of its ability to meet key technical challenges including such things as adequate natural circulation for thermal management and capability for operational periods up to 8 years. Thermal management concerns have begun to be addressed and are not expected to be a problem (Pearson, 2007). One significant concern remaining is the ability to maintain the shield integrity through its operational lifetime. Shield integrity could be compromised through shield pressurization and corrosion resulting from the radiolytic decomposition of water.

  18. The effect of temperature on radiolysis of iodide ion diluted aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Gorbovitskaya, T.; Tiliks, J. [Latvia Univ., Lab. of Radiation Chemistry, Riga (Latvia)

    1996-12-01

    To investigate the radiolysis of iodine containing aqueous solutions a flow type facility (ITF) has a possibility to irradiate aqueous solutions in the steel vessel with {sup 60}Co {gamma}-rays and continuously (on line) to analyze the products of radiolysis both in liquid and in gaseous phases. By means of ITF the formation of I{sub ox} (I{sub 2} + I{sub 3}{sup -} + HOI), IO{sub 3}{sup -}, H{sub 2}O{sub 2} was studied in 10{sup -5} - 10{sup -3} mol/dm{sup 3} CsI aqueous solutions by their radiolysis at dose rate 4.5 kGv/h for six hours in region of temperatures from 313 to 404 K. Some experiments in glass ampoules were also performed. The steady-state concentrations of I{sub ox} and IO{sub 3}{sup -} decreased with increasing temperature as linear function of inverted temperature. The effect decreased with decreasing concentration of iodide ion. As the result, at high temperatures (T{>=}380 K) the steady-state concentration of I{sub ox} does not depend essentially on the iodide ion initial concentration. Molecular iodine (I{sub 2}) released from the solution was the main radiolysis product in gaseous phase. Its steady-state concentration increased with increasing temperature because of iodine solubility in the water and decreased at the same time because the radiolytic iodine concentrations decreased. Therefore the most volatility of irradiated 10{sup -3} and 10{sup -4}M CsI solutions was observed at the temperature about 350 K. The volatility of 10{sup -5}M solutions gradually decreased with increasing temperature. The experimental data were explained on the base of the hypothesis that the reaction between I{sub 2} and radiolytic H{sub 2}O{sub 2} was the limit one determining the temperature dependence of I{sub ox} and IO{sub 3}{sup -}steady-state concentrations. Its activation energy was estimated to be 27,5 kcal.mol{sup -1}. The temperature dependence for reaction (IO{sup -} + H{sub 2}O{sub 2}) was also estimated. (author) 8 figs., 1 tab., 17 refs.

  19. The possible role of hydrothermal vents in chemical evolution: Succinic acid radiolysis and thermolysis

    Science.gov (United States)

    Cruz-Castañeda, J.; Colín-García, M.; Negrón-Mendoza, A.

    2014-07-01

    In this research, the behavior under a high radiation field or high temperature of succinic acid, a dicarboxylic acid clue in metabolic routes, is studied. For this purpose, the molecule was irradiated with gamma rays in oxygen-free aqueous solutions, and the thermal decomposition was studied in a static system at temperatures up to 90 °C, simulating a white hydrothermal vent. Our results indicate that a succinic acid is a relatively stable compound under irradiation. The gamma radiolysis yields carbon dioxide and di- and tricarboxylic acids such as malonic, carboxysuccinic, and citric acids. The main products obtained by the thermal treatment were CO2 and propionic acid.

  20. Gamma-radiolysis of TBP and DBPA in the presence of HNO/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Kulikov, I.A.; Kermanova, N.V.; Vladimirova, M.V.

    1985-09-01

    The authors show that DBPA, MBPA, H/sub 3/PO/sub 4/, polymer, nitration and oxidation products, hydrogen, and gaseous products (methane, ethane, etc.) are formed. When oxygen or air is bubbled through the two-phase system, the rate of formation of acidic radiolysis products is constant over gamma irradiation doses and is greater than the rate of formation in oxygen-deficient systems. It has been shown that /sup G/ DBPA and /sup G/ MBPA and the equilibrium concentrations of DBPA are greater. Other conditions being equal, the greater is the concentration of metal ions (Pu/sup 4 +/, UO/sup 2 +//sub 2/) in the extractant.

  1. Water radiolysis by low-energy carbon projectiles from first-principles molecular dynamics

    Science.gov (United States)

    Kohanoff, Jorge

    2017-01-01

    Water radiolysis by low-energy carbon projectiles is studied by first-principles molecular dynamics. Carbon projectiles of kinetic energies between 175 eV and 2.8 keV are shot across liquid water. Apart from translational, rotational and vibrational excitation, they produce water dissociation. The most abundant products are H and OH fragments. We find that the maximum spatial production of radiolysis products, not only occurs at low velocities, but also well below the maximum of energy deposition, reaching one H every 5 Å at the lowest speed studied (1 Bohr/fs), dissociative collisions being more significant at low velocity while the amount of energy required to dissociate water is constant and much smaller than the projectile’s energy. A substantial fraction of the energy transferred to fragments, especially for high velocity projectiles, is in the form of kinetic energy, such fragments becoming secondary projectiles themselves. High velocity projectiles give rise to well-defined binary collisions, which should be amenable to binary approximations. This is not the case for lower velocities, where multiple collision events are observed. H secondary projectiles tend to move as radicals at high velocity, as cations when slower. We observe the generation of new species such as hydrogen peroxide and formic acid. The former occurs when an O radical created in the collision process attacks a water molecule at the O site. The latter when the C projectile is completely stopped and reacts with two water molecules. PMID:28267804

  2. Radiolysis of TBP in the presence of plutonium and uranium. [Gamma radiation; alpha sources

    Energy Technology Data Exchange (ETDEWEB)

    Kulikov, I.A.; Kermanov, N.V.; Vladimirova, M.V.

    1983-01-01

    Using the methods of potentiometry, spectrophotometry and chromatography the yields of TBP decomposition products during ..cap alpha..- and ..gamma..-radiolysis in the two-phase system of 30% TBP in n-paraffin-3.0 mol/l HNO/sub 3/ in the presence of Pusup((4)) (10/sup -3/-10/sup -1/ mol/l) and Usup((6)) (0.01-0.3 mol/l) have been determined. Formation yields of Pusup((4)) complexes with dibutylphosphoric acid (DBPA) and monobutylphosphoric (MBPA) acid in the two-phase system studied are found. It is shown that, with an increase in (Me) from 0.01 to 0.3 mol/l, the G of DBPA increases from 1.9 to 3.0, and the G of MBPA - from 0.3 to 0.45 molecules/100 eV. Radiative gas evolution composition and yields of gaseous radiolysis products of the organic phase have been studied. Kinetics of DBPA formation in the presence of plutonium is considered. Constants of DBPA formation and decomposition rates are determined. On the basis of experimental data the maximum yield of the TBP decomposition is calculated to be equal to approximately 6.0 molecules/100 eV.

  3. Radiolysis of pyridoxine (vitamin B 6) in aqueous solution under different conditions

    Science.gov (United States)

    Albarrán, Guadalupe; Ramírez-Cahero, Fernando; Aliev, Roustam

    2008-05-01

    Aqueous solutions of pyridoxine (1 mM) without or with additive of K 3[Fe(CN) 6] (2.5 mM) were gamma-irradiated at different doses and dose rate of 2.16 kGy/h in the absence of air, in the presence of air or by their saturation with N 2O. The radiolytic products were analyzed with HPLC, mass spectrometry and UV spectroscopy. 2,4,5-Trihydroxymethyl-3-pyridinol, pyridoxal, isopyridoxal and 6-hydroxypyridoxine were formed by radiolysis in the absence of K 3[Fe(CN) 6], and their concentrations were much higher in samples saturated with N 2O. Pyridoxi-3,6-quinone was found by radiolysis under all the above-mentioned conditions but only in the presence of K 3[Fe(CN) 6]. Besides, the pyridoxal formation increased in the presence of this oxidizing agent. G values of pyridoxal formation and pyridoxine degradation were quantified. Some details of the radiolytic product formation were discussed.

  4. The radiolysis of CMPO: effects of acid, metal complexation and alpha vs. gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mincher, B.J.; Groenewold, G.S. [Idaho National Laboratory, PO Box 1625, Idaho Falls, ID 83415 (United States); Mezyk, S.P. [California State University at Long Beach, Long Beach, CA 90840 (United States)

    2016-07-01

    The organophosphorus amide octyl(phenyl)-N,N-diisobutyl-carbamoylmethyl phosphine oxide (CMPO) is proposed for use in fuel cycle separations as a group actinide/lanthanide extractant. Alternative compounds such as the mono-amides and diglycol amides (DGAs) proposed for actinide and/or actinide/lanthanide extraction also contain the amidic functional group, but do not contain the CMPO aromatic or phosphoryl groups. Their radiation stability is in the order mono-amides > CMPO > DGA for irradiation under similar conditions. Although they produce similar radiolysis products, the kinetics of degradation for CMPO are completely different than for the other amides. CMPO degradation occurs in a zero-order fashion, and the -G-value for the change in [CMPO] is much lower when in the presence of acid. The DGAs and mono-amides degrade with pseudo-first-order kinetics and are not protected by acidity. Possible mechanistic reasons for the differences between CMPO and the other amides are discussed, as are the effects of the diluent and metal complexation on CMPO free radical reaction rates. Finally, it is also shown that α-irradiation has much less adverse effects on CMPO degradation than β/γ irradiation, both with respect to -G-values, and radiolysis product generation. (authors)

  5. Semi-quantitative and quantitative studies on the gamma radiolysis of C5-BTBP

    Energy Technology Data Exchange (ETDEWEB)

    Fermvik, A.; Ekberg, C. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Nuclear Chemistry; Chalmers Univ. of Technology, Goeteborg (Sweden). Industrial Materials Recycling; Gruener, B.; Kvicalova, M. [Academy of Sciences of the Czech Republic, Husinec-Rez near Prague (Czech Republic). Inst. of Inorganic Chemistry

    2011-07-01

    An industrial liquid-liquid extraction process for reprocessing of spent nuclear fuel will inevitably lead to radiolysis of the phases, since the process streams contain highly radioactive species. Solvents containing one of the BTBP (6,6'-bis(5,6-dialkyl-[1,2,4]-triazin-3-yl)-2,2'-bipyridine) molecules intended for the separation of trivalent actinides (An) from lanthanides (Ln), the so called C5-BTBP, have shown a dramatic decrease in both distribution ratios and An/Ln separation factor when irradiated; hence, the molecule is highly unstable towards radiolysis. HPLC-, APCI(+)-MS and LC-MS analyses were performed on irradiated solvents containing initially 0.005 M C5-BTBP dissolved in either hexanol or cyclohexanone. The decrease in concentration of starting molecule as well as the increase in concentration of various degradation products were studied with quantitative and semi-quantitative measurements. Structures were suggested for the degradation products produced in highest yields and these were compared to previously proposed structures for the same products. (orig.)

  6. An ESR study of the gamma radiolysis of aromatic polyesters containing isomeric naphthalene links

    Science.gov (United States)

    Hill, David J. T.; Choi, Bong-Ku; Ahn, Hung-Kun; Choi, E.-Joon

    2001-07-01

    Six polyesters were synthesised from 4,4'-oxy-bis(benzoyl chloride) and 1,4-, 1,5-, 1,6-, 2,3-, 2,6-, and 2,7-naphthalenediol isomers. The structures of the polyesters were characterised by means of IR, inherent viscosities in tetrachloroethane (TCE), solutions at 303 K and thermal analysis. The glass transition temperatures were in the range of 425-494 K by DSC thermal analysis. All of the polyesters were irradiated in an AECL Gammacell 220 unit at a dose rate of approximately 6.7 kGy/h to doses in the range of 0-15 kGy at 77 and 300 K. ESR spectroscopy was used to examine the radicals formed during radiolysis and to measure their yields. The G-values for radical formation in the polyesters were found to be in the range 0.18-1.41 at 77 K and 0.19-0.78 at 300 K. At 77 K, up to 15% of the radicals formed on radiolysis were found to be photo-bleachable anion radicals. Annealing experiments were carried out in order to identify the neutral radicals, which were assigned to naphthyl- or phenyl- and phenoxyl-type radicals.

  7. Effects of the radiolysis products of sennoside A on HepG2 and PC-3 cell

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Ho; Jo, Min Ho [Research Division for Biotechnology, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2016-11-15

    Radiolysis of sennoside A was carried out by gamma irradiation and the anti-cancer activities of the radiolysis product were evaluated. An aqueous solution of sennoside A was exposed to 0.5-3 kGy of gamma irradiation and the radiolysis products were analyzed by HPLC. A fraction of radiolysis product (RLF) of sennoside A was isolated and the RLF was presumed as a rhein-8-β-D-glucoside. The anticancer effect of the RLF was compared with the sennoside and rhein using a in vitro assay system of human prostate cancer cells (PC-3) and human hepatoma HepG2 cells. The cell viability of PC-3 and HepG2 cell was significantly decreased to 12.4±1.2% and 32.4±2.1%, respectively, by the treatment of 0.6 μM of RLF. The sennoside A (range from 0 to 25 μM) had no cytotoxic effect on PC-3 and HepG2 cells, while the rhein had the effect on HepG2 cells with a LD{sub 50} at 80 μM.

  8. Aspects of the physics and chemistry of water radiolysis by fast neutrons and fast electrons in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    McCracken, D.R. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Tsang, K.T. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Laughton, P.J

    1998-09-01

    Detailed radiation physics calculations of energy deposition have been done for the coolant of CANDU reactors and Pressurized Water Reactors (PWRs). The geometry of the CANDU fuel channel was modelled in detail. Fluxes and energy-deposition rates for neutrons, recoil ions, photons, and fast electrons have been calculated using MCNP4B, WIMS-AECL, and specifically derived energy-transfer factors. These factors generate the energy/flux spectra of recoil ions from fast-neutron energy/flux spectra. The energy spectrum was divided into 89 discrete ranges (energy bins).The production of oxidizing species and net coolant radiolysis can be suppressed by the addition of hydrogen to the coolant of nuclear reactors. It is argued that the net dissociation of coolant by gamma rays is suppressed by lower levels of excess hydrogen than when dissociation is by ion recoils. This has consequences for the modelling of coolant radiolysis by homogeneous kinetics. More added hydrogen is required to stop water radiolysis by recoil ions acting alone than if recoil ions and gamma rays acted concurrently in space and time. Homogeneous kinetic models and experimental data suggest that track overlap is very inefficient in providing radicals from gamma-ray tracks to recombine molecular products in ion-recoil tracks. An inhomogeneous chemical model is needed that incorporates ionizing-particle track structure and track overlap. Such a model does not yet exist, but a number of limiting cases using homogeneous kinetics are discussed. There are sufficient uncertainties and contradictions in the data relevant to the radiolysis of reactor coolant that the relatively high CHC's (critical hydrogen concentration) observed in NRU reactor experiments (compared to model predictions) may be explainable by errors in fundamental data and understanding of water radiolysis under reactor conditions. The radiation chemistry program at CRL has been focused to generate quantitative water-radiolysis data in a

  9. A study of solute transport of radiolysis products in crud and its effects on crud growth on PWR fuel pin

    Energy Technology Data Exchange (ETDEWEB)

    Joe, Justin H. [BNF Consulting (United States); Kim, Seung Jun, E-mail: skim@lanl.gov [Mechanical and Thermal Engineering Group (AET-1), Los Alamos National Laboratory (United States); Jones, Barclay G. [Department of Nuclear Plasma Radiological Engineering, University of Illinois Urbana-Champaign (United States)

    2016-04-15

    Highlights: • We model a 3-D numerical solute transport within crud deposit on PWR fuel pin. • Source term effect from radiolysis yield and recombination is minimal. • Lower crud porosity leads substantially higher concentration of solutes. • Thicker crud deposit generates substantially higher concentration of solutes. • High concentration of radiolysis species (H{sub 2}, O{sub 2}, and H{sub 2}O{sub 2}) can be directly related to corrosion issues on fuel cladding. - Abstract: This research examines the concentration of radiolysis species (H{sub 2}, O{sub 2}, and H{sub 2}O{sub 2}) over the porous crud layer using a three dimensional time dependent solute transport model. A Monte Carlo random walk technique is adopted to simulate the transport behavior of the different species with various parametric studies of source term, crud thickness, and crud porosity. Particularly, this model employs a system of coupled mass transport and chemical interactions as the source term, which makes the problem non-linear. It is demonstrated that a negligible effect on radiolysis species concentrations change due to the consideration of source term. The crud thickness and porosity effect on the concentration distributions are notably observed. In general, higher concentration starts from the intersection of the heating surface with the chimney wall from the beginning and it reaches the equilibrium state within tens of seconds. The concentration profiles of the radiolysis species H{sub 2}, O{sub 2}, and H{sub 2}O{sub 2} can be directly related to corrosion issues. The direct application of this study to nuclear engineering research is to aid in the design of reactors with higher performance without experiencing an Axial Offset Anomaly (AOA), an unexpected measured shift in axial power distribution from predicted values.

  10. Coupling the Mixed Potential and Radiolysis Models for Used Fuel Degradation

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Edgar C.; Jerden, James L.; Ebert, William L.; Wittman, Richard S.

    2013-08-30

    The primary purpose of this report is to describe the strategy for coupling three process level models to produce an integrated Used Fuel Degradation Model (FDM). The FDM, which is based on fundamental chemical and physical principals, provides direct calculation of radionuclide source terms for use in repository performance assessments. The G-value for H2O2 production (Gcond) to be used in the Mixed Potential Model (MPM) (H2O2 is the only radiolytic product presently included but others will be added as appropriate) needs to account for intermediate spur reactions. The effects of these intermediate reactions on [H2O2] are accounted for in the Radiolysis Model (RM). This report details methods for applying RM calculations that encompass the effects of these fast interactions on [H2O2] as the solution composition evolves during successive MPM iterations and then represent the steady-state [H2O2] in terms of an “effective instantaneous or conditional” generation value (Gcond). It is anticipated that the value of Gcond will change slowly as the reaction progresses through several iterations of the MPM as changes in the nature of fuel surface occur. The Gcond values will be calculated with the RM either after several iterations or when concentrations of key reactants reach threshold values determined from previous sensitivity runs. Sensitivity runs with RM indicate significant changes in G-value can occur over narrow composition ranges. The objective of the mixed potential model (MPM) is to calculate the used fuel degradation rates for a wide range of disposal environments to provide the source term radionuclide release rates for generic repository concepts. The fuel degradation rate is calculated for chemical and oxidative dissolution mechanisms using mixed potential theory to account for all relevant redox reactions at the fuel surface, including those involving oxidants produced by solution radiolysis and provided by the radiolysis model (RM). The RM calculates

  11. Radiolysis compounds in bacon and chicken. Final report 18 Sep 81-20 Sep 82

    Energy Technology Data Exchange (ETDEWEB)

    Merritt, C. Jr.

    1984-01-01

    The results of this study are in agreement with the precepts established in studies published previously on beef, chicken, ham, and pork. The radiolysis compounds from bacon, chicken, ham, and pork are comparable in identity and amounts to those found in irradiated beef for comparable compositions and irradiation parameters (temperature, dose, etc.). The results of this study support the conclusions drawn in the CORC report of 'commonality in chemistry, predictability of products, and extrapolation of results.' Consequently, the same conclusions can be drawn concerning the wholesomeness of irradiated bacon, chicken, ham, and pork as for other irradiated meat products of similar composition and irradiation parameters as reported in the FASEB report and its supplements (I and II) on irradiated beef.

  12. Radiolysis of Boric Acid Solutions under Mixed Thermal and Fast Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Im, Heejung; Choi, Ke Chon; Yeon, Jeiwon; Song, Kyuseok; Jung Hoansung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The thermal neutron irradiation of water samples containing neutron absorbers has not been published except for a paper reporting the experimental data obtained at high temperatures. However, irradiation or simulations of water and voluminous liquid samples with fast neutrons and gamma rays are frequently discussed in several published papers. Several water samples containing {sup 10}B-enriched boric acid, and natural and {sup 10}B-enriched mixed boric acids in the range of 0 to 2000 μg/mL for the function of {sup 10}B concentration, were irradiated to study the radiolysis of the cooling water containing boric acid. The concentration of natural boron in the primary coolant of pressurized water reactors (PWRs) is known to start at 1500 μg/mL, and boric acid is used for the purpose of nuclear reaction control.

  13. Radiolysis of Amino Acids in Outer Solar-System Ice Analogs

    Science.gov (United States)

    Gerakines, Perry A.; Hudson, Reggie L.

    2011-01-01

    Amino acids have been found in cometary dust particles and in the organic component of meteorites. These molecules, important for pre-biotic chemistry and for active biological systems, might be formed in cold planetary or interstellar environments and then delivered to H20-rich surfaces in the outer solar system. Many models for the availability of organic species on Earth and elsewhere depend on the ability of these molecules to survive in radiation-rich space environments. This poster presents results of O.8-MeV proton radiolysis of ice films at lS-140K. using infrared spectroscopy, the destruction rates of glycine, alanine, and phenylalanine have been determined for both pure films and those containing amino acids diluted in H2o. our results are discussed in terms of the survivability of these molecules in the icy surfaces present in the outer solar system and the possibility of their detection by instruments on board the New Horizons spacecraft

  14. Monte Carlo simulation of indirect damage to biomolecules irradiated in aqueous solution: The radiolysis of glycylglycine

    Energy Technology Data Exchange (ETDEWEB)

    Bolch, W.E.; Turner, J.E.; Yoshida, H.; Jacobson, K.B.; Hamm, R.N.; Wright, H.A.; Ritchie, R.H.; Klots, C.E.

    1988-07-01

    A Monte Carlo computer code is developed for simulating the radiolysis of glycylglycine in both oxygenated and deoxygenated aqueous solution. Second, this model is used to calculate the yields of various products in solutions irradiated either by 250-kVp X-rays or by /sup 60/Co gamma rays. Third, calculated product yields are compared to measured yields where available. The Monte Carlo computer codes used in this study are modified and extended versions of three existing simulation codes, written at the Oak Ridge National Laboratory (ORNL), which simulate irradiations of pure liquid water. The ORNL codes calculate the formation, diffusion, and reaction of free radicals and other species along charged-particle tracks in liquid water. As part of this research, these codes are extended to simulate irradiation of pure oxygenated water, oxygenated glycylglycine solutions, and deoxygenated glycylglycine solutions. 80 refs., 38 figs., 8 tabs.

  15. Risk analysis for a radiolysis gas detonation in an in-pile loop with supercritical water; Risiko einer Radiolysegasdetonation in einem aktiven Versuchskreislauf mit ueberkritischem Wasser

    Energy Technology Data Exchange (ETDEWEB)

    Zeiger, T.; Raque, M.; Kuznetsov, M.; Redlinger, R.; Schulenberg, T. [Karlsruher Institut fuer Technologie (KIT), Eggenstein-Leopoldshafen (Germany). Inst. fuer Kern- und Energietechnik (IKET)

    2012-11-01

    The SCWR (supercritical water reactor) -FQT project is a cooperation between European and Chinese partners aimed to test the fuel SCWR elements under reactor conditions. In the frame of this work the risk of radiolysis gas production in the active range of the test track was assessed. The radiolysis gas could accumulate in an emergency cooling system with stagnating coolant. The ignition of this radiolysis gas could cause pressure peaks that are able to damage the primary coolant circuit. Pressure increase and deformations in case of ignition of accumulated gas were investigated. As piping material the Ti stabilized austenitic steel 08Ch18N10T was assumed, the simulation was performed using the ANSYS code. The results show that pipes without significant wall thickness enhancement cannot withstand the radiolysis gas detonation.

  16. One electron reduction and oxidation of 2-, 3- and 4-chlorobenzonitrile in aqueous solution: A pulse radiolysis study

    DEFF Research Database (Denmark)

    Geppert, W.D.; Getoff, N.; Sehested, K.

    2000-01-01

    Solvated electrons (e(aq)(-)) react with very high rates (k > 10(10) dm(3) mol(-1) s(-1)) with 2-, 3- and 4-monochlorbenzonitriles (2-, 3- and 4-C1BN) to yield the corresponding radical anions. The anions decay in neutral solution under dechlorination by a first-order reaction, where the k(1......)-values of 2- and 4-C1BN species are about three orders of magnitude higher than that of 3-C1BN. At low pHs, the 3-CIBN.- transient protonates k = 2.6 x 10(10) dm(3) mol(-1) s(-1) and the resulting species disappears by a second-order process (2k = 2 x 10(9) dm(3) mol(-1) s(-1)). The spectrum...... of the protonated 3-C1BN(.-) transient strongly differs from that of the H-adduct. Hence, the protonation of the radical anions seems to occur at the cyano group. The H-atoms form the respective adducts with rates from 2.2 to 3.4 x 10(9) dm(3) mol(-1) s(-1), which disappear by a second-order process with rate...

  17. Investigation of molecular mechanisms in photodynamic action and radiobiology with nanosecond flash photolysis and pulse radiolysis. Progress report, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Grossweiner, L.I.

    1983-01-01

    Liposomes have been employed as membrane models applicable to photosensitization in phototherapy procedures. The results with 8-methoxypsoralen, the sensitizer in PUVA therapy of psoriasis, show that singlet oxygen generated by near-uv (uv-A) irradiation induces membrane damage leading to lysis. A similar role of singlet oxygen has been shown for photosensitization of liposomes by methylene blue, with the new observation that hydrodynamic forces promote the lytic action initiated by singlet oxygen attack on an unsaturated site of phosphatidylcholine. Liposome photosensitization by hematoporphyrin follows a Type II mechanism mediated by singlet oxygen for low sensitizer concentrations, and a Type I, anoxic, mechanism when the hematoporphyrin is aggregated. Similar concentration effects obtain with hematoporphyrin derivative (hpd), the photosensitizer in photoradiation therapy of malignant tumors. Studies on the components of hpd separated by gel chromatography show that the putative biological active fraction can photosensitize membrane damage under oxic and anoxic conditions. The oxic pathway was suppressed by binding to human serum albumin, as involved in serum transport of hpd prior to localization in tumor tissue. A study on hematoporphyrin photosensitization of targets other than membranes has shown that singlet oxygen is responsible for the photosensitized inactivation of subtilisin BPN' and photooxidation of tryptophan in human and bovine serum albumin. In the case of the serum proteins, the singlet oxygen is generated by the sensitizer-protein complex and it may react with all protein in the system. 11 references.

  18. Measuring hydrogen peroxide due to water radiolysis using a modified horseradish peroxidase based biosensor as an alternative dosimetry method.

    Science.gov (United States)

    Tavakoli, Hassan; Baghbanan, Amin Azam

    2015-08-01

    H2O2 generated during water radiolysis was measured electrochemically as an alternative dosimetry method. A biosensor was fabricated by immobilising modified horseradish peroxidase (HRP) on a glassy carbon electrode (GCE) followed by evaluation of its analytical parameters. Anthraquinone 2-carboxylic acid was used to modify HRP. To assess sensor performance, phosphate buffer solutions were irradiated with 0.510 Gy of gamma ray emitted from (60)Co. The results showed that this sensor can detect low quantities of hydrogen peroxide in water radiolysis. Sensitivity, detection limit and linear range of the biosensor were 260 nA/Gy, 0.392 Gy and 0.5-5 Gy, respectively. Long term stability studies showed that sensor responses were stable for at least a month. The cathodic peak current, as biosensor response, subsequently decreased to 20% of its initial value.

  19. Radiolysis of D(+)-carnitine by /sup 60/Co-. gamma. -radiation and formation of L(+)-. beta. -methylcholine

    Energy Technology Data Exchange (ETDEWEB)

    Loester, Heinz; Strack, Erich; Seim, Hermann

    1986-06-01

    The radiolysis of D(+)-carnitine by /sup 60/Co-..gamma..-radiation was examined to obtain optically active ..beta..-methylcholine. It was found that the radiolysis leads to a number of trimethylammonium bases but to no other betaines. (+)-..beta..-Methylcholine and acetonyltrimethylammonium could be identified by means of common analytical methods. The amounts of methylamines formed by irradiation were very small. Racemization of the D(+)-carnitine did not occur during irradiation, L(-)-carnitine was not found when an enzymatical determination method was used. The fact that (+)-..beta..-methylcholine was formed from D(+)-carnitine is pharmacologically important, because acetyl-L(+)-..beta..-methylcholine has a strong interaction with muscarinic receptors.

  20. Pulsed laser excitation of phosphate stabilised silver nanoparticles

    Indian Academy of Sciences (India)

    Jyotirmayee Mohanty; Dipak K Palit; Laxminarayan V Shastri; Avinash V Sapre

    2000-02-01

    Laser flash photolysis studies were carried out on two types of silver nanoparticles prepared by -radiolysis of Ag+ solutions in the presence of polyphosphate as the stabiliser. Type I silver nanoparticles displayed a surface plasmon band at 390 nm. Type II silver nanoparticles showed a 390 nm surface plasmon band with a shoulder at 550 nm. On photoexcitation in the surface plasmon band region, using 35 picosecond laser pulses at 355 nm and 532 nm, the type II solutions showed transient bleaching and absorption signals in the 450-900 nm region, which did not decay appreciably up to 5 nanoseconds. These transient changes were found to get annealed in the interval where 5 ns < < 100 ns. Extended photolysis of the nanoparticle solutions with repetitive laser pulses resulted in a decrease in the values of the average particle size which were measured by employing the dynamic light scattering technique.

  1. Water radiolysis in exchanged-montmorillonites: the H2 production mechanisms.

    Science.gov (United States)

    Fourdrin, C; Aarrachi, H; Latrille, C; Esnouf, S; Bergaya, F; Le Caër, S

    2013-08-20

    The radiolysis of water confined in montmorillonites is studied as a function of the composition of the montmorillonite, the nature of the exchangeable cation, and the relative humidity by following the H2 production under electron irradiation. It is shown that the main factor influencing this H2 production is the water amount in the interlayer space. The effect of the exchangeable cation is linked to its hydration enthalpy. When the water amount is high enough to get a basal distance higher than 1.3 nm, then a total energy transfer from the montmorillonite sheets to the interlayer space occurs, and the H2 production measured is very similar to the one obtained in bulk water. For a basal distance smaller than 1.3 nm, the H2 production increases with the relative humidity and thus with the water amount. Lastly, electron paramagnetic resonance measurements evidence the formation of a new defect induced by ionizing radiation. It consists of a hydrogen radical (H2 precursor) trapped in the structure. This implies that structural hydroxyl bonds can be broken under irradiation, potentially accounting for the observed H2 production.

  2. Experimental evidence of the influence of iron on pore water radiolysis in cement-based materials

    Energy Technology Data Exchange (ETDEWEB)

    Bouniol, P., E-mail: pascal.bouniol@cea.fr [CEA, DEN, DPC, SECR, Laboratoire d’Etude du Comportement des Bétons et des Argiles, F-91991 Gif-Sur-Yvette (France); Muzeau, B. [CEA, DEN, DPC, SECR, Laboratoire d’Etude du Comportement des Bétons et des Argiles, F-91991 Gif-Sur-Yvette (France); Dauvois, V. [CEA, DEN, DPC, SECR, Laboratoire de Radiolyse et de la Matière Organique, F-91991 Gif-Sur-Yvette (France)

    2013-06-15

    Hydrated tricalcium silicate based cement pastes or mixes, with the addition or not of amorphous iron oxyhydroxide, were irradiated for 1 year in a closed system (γ radiation) with the aim of provoking radiolysis of the alkaline pore solution (pH > 13). The data collected (on-line monitoring of the total pressure and the H{sub 2} content in 500 cm{sup 3} mini-containers irradiated at 45 °C and 1.07 kGy/h with V{sub gas}/V{sub paste} ≈ 1) enable us to conclude that the addition of 1% of FeOOH{sub am} gives rise to about 26% of additional residual H{sub 2} after 1 year. This result appears to validate the hypothesis of a partial mobilisation of the e{sub aq}{sup -} and O{sup ·−} radicals in a continuous process of Fe(III) ↔ Fe(II) oxidation–reduction, at the expense of their action within the Allen type reaction chain that is responsible for the recycling of H{sub 2}. Despite the complexity of the porous material, the simulation of the experiment with the CHEMSIMUL application leads to a result that is quite close, and stresses the importance of the kinetic coupling between gas transport in the porous material and the reaction system.

  3. Pulse radiolytic studies of electron transfer processes and applications to solar photochemistry. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Neta, P.

    1995-02-01

    The pulse radiolysis technique is applied to the study of electron transfer processes in a variety of chemical systems. Reactive intermediates are produced in solution by electron pulse irradiation and the kinetics of their reactions are followed by time resolved absorption spectrophotometry. Complementary experiments are carried out with excimer laser flash photolysis. These studies are concerned with mechanisms, kinetics, and thermodynamics of reactions of organic and inorganic radicals and unstable oxidation states of metal ions. Reactions are studied in both aqueous and non-aqueous solutions. The studies focus on the unique ability of pulse radiolysis to provide absolute rate constants for reactions of many inorganic radicals and organic peroxyl radicals, species that are key intermediates in many chemical processes. A special concern of this work is the study of electron transfer reactions of metalloporphyrins, which permits evaluation of these molecules as intermediates in solar energy conversion. Metalloporphyrins react with free radicals via electron transfer, involving the ligand or the metal center, or via bonding to the metal, leading to a variety of chemical species whose behavior is also investigated. The highlights of the results during the past three years are summarized below under the following sections: (a) electron transfer reactions of peroxyl radicals, concentrating on the characterization of new peroxyl radicals derived from vinyl, phenyl, other aryl, and pyridyl; (b) solvent effects on electron transfer reactions of inorganic and organic peroxyl radicals, including reactions with porphyrins, and (c) electron transfer and alkylation reactions of metalloporphyrins and other complexes.

  4. Long term evolution of recycled DIAMEX solvent properties under hydrolysis and radiolysis with or without solvent clean-up

    Energy Technology Data Exchange (ETDEWEB)

    Cames, B.; Saucerotte, B.; Faucon, M.; Rudloff, D.; Gastaldi, M.; Bisel, I

    2004-07-01

    As part of the SPIN program, CEA has developed DIAMEX process allowing co-extraction of actinides(III) and lanthanides(III) thanks to a diamide extractant, the Di-Methyl Di-Octyl Hexyl-Ethoxy Malonamide, symbolized by DMDOHEMA. Along the different process steps, diamide undergoes radiolytic and hydrolytic degradation leading to reaction products changing extraction performances and hydrodynamic behavior of the solvent. If to be industrially used, extractant has to be recycled. Therefore an alkaline solvent clean-up step has been defined to remove acidic degradation products whose modifying extraction properties. Nevertheless long-term recycling may allow accumulation of amounts of products which can influence process operating and separation performances. MARCEL is a laboratory scale bench mark, simulating chemical and radiolytic conditions of the process, designed for the long term evolution studies of the recycled solvent properties. Extraction, scrubbing and stripping are performed in mixer-settlers whereas centrifugal contactors are used for solvent clean-up. Different flow-sheets have been tested through various runs during about 200 hours each: - Hydrolysis with or without solvent clean-up; - Hydrolysis coupled with radiolysis with solvent clean-up. For each solvent cycle, DMDOHEMA undergoes a 2.5 hours hydrolysis at 40 deg C and, if radiolysis is studied, a 8.5 kGy exposure. Solvent properties have been followed-up by steady tests (viscosity, density, surface tension, refraction index, phase settling time ratio (RTD), distribution coefficients of several cations) and quantitative analysis of the degradation products. The efficiency and correct hydrodynamic behavior of the alkaline treatment has been shown, remaining hydrolysis and radiolysis degradation products having no significant influence on solvent properties. (authors)

  5. Radiolysis of astrophysical ice analogs by energetic ions: the effect of projectile mass and ice temperature.

    Science.gov (United States)

    Pilling, Sergio; Duarte, Eduardo Seperuelo; Domaracka, Alicja; Rothard, Hermann; Boduch, Philippe; da Silveira, Enio F

    2011-09-21

    An experimental study of the interaction of highly charged, energetic ions (52 MeV (58)Ni(13+) and 15.7 MeV (16)O(5+)) with mixed H(2)O : C(18)O(2) astrophysical ice analogs at two different temperatures is presented. This analysis aims to simulate the chemical and the physicochemical interactions induced by cosmic rays inside dense, cold astrophysical environments, such as molecular clouds or protostellar clouds as well at the surface of outer solar system bodies. The measurements were performed at the heavy ion accelerator GANIL (Grand Accelerateur National d'Ions Lourds) in Caen, France. The gas samples were deposited onto a CsI substrate at 13 K and 80 K. In situ analysis was performed by a Fourier transform infrared (FTIR) spectrometer at different fluences. Radiolysis yields of the produced species were quantified. The dissociation cross section at 13 K of both H(2)O and CO(2) is about 3-4 times smaller when O ions are employed. The ice temperature seems to affect differently each species when the same projectile was employed. The formation cross section at 13 K of molecules such as C(18)O, CO (with oxygen from water), and H(2)O(2) increases when Ni ions are employed. The formation of organic compounds seems to be enhanced by the oxygen projectiles and at lower temperatures. In addition, because the organic production at 13 K is at least 4 times higher than the value at 80 K, we also expect that interstellar ices are more organic-rich than the surfaces of outer solar system bodies.

  6. Hazardous and Corrosive Gas Production in the Radiolysis of Water/Organic Mixtures in Model TRU Waste

    Energy Technology Data Exchange (ETDEWEB)

    LaVerne, Jay A.

    2005-06-01

    Experiments in combination with diffusion-kinetic modeling incorporating track structure simulations are used to examine the radiation chemistry of aqueous systems containing chlorinated hydrocarbons. Irradiations with both Co-60 gamma rays and alpha particles are employed in order to simulate typical mixed radiation environments encountered in waste management. The goal is to determine fundamental mechanisms, kinetics, and yields for the formation of potentially explosive gases and corrosive agents, such as H2 and HCl, respectively, in the radiolysis of water-organic mixtures. The radiation chemical systems studied are found throughout the DOE portfolio and are important in radioactive waste remediation and management.

  7. Impacts of glycolate and formate radiolysis and thermolysis on hydrogen generation rate calculations for the Savannah River Site tank farm

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); King, W. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-08-14

    Savannah River Remediation (SRR) personnel requested that the Savannah River National Laboratory (SRNL) evaluate available data and determine its applicability to defining the impact of planned glycolate anion additions to Savannah River Site (SRS) High Level Waste (HLW) on Tank Farm flammability (primarily with regard to H2 production). Flammability evaluations of formate anion, which is already present in SRS waste, were also needed. This report describes the impacts of glycolate and formate radiolysis and thermolysis on Hydrogen Generation Rate (HGR) calculations for the SRS Tank Farm.

  8. Alpha Radiolysis of Nuclear Solvent Extraction Ligands Used for An(III) and Ln(III) Separations

    Energy Technology Data Exchange (ETDEWEB)

    Mezyk, Stephen P. [California State Univ. (CalState), Long Beach, CA (United States); Mincher, Bruce J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Nilsson, Mikael [Univ. of California, Irvine, CA (United States)

    2016-08-01

    This document is the final report for the Nuclear Energy Universities Program (NEUP) grant 10-910 (DE-AC07-05ID14517) “Alpha Radiolysis of Nuclear Solvent Extraction Ligands used for An(III) and Ln(III) Separations”. The goal of this work was to obtain a quantitative understanding of the impacts of both low Linear Energy Transfer (LET, gamma-rays) and high LET (alpha particles) radiation chemistry occurring in future large-scale separations processes. This quantitative understanding of the major radiation effects on diluents and ligands is essential for optimal process implementation, and could result in significant cost savings in the future.

  9. Pulse Voltammetry.

    Science.gov (United States)

    Osteryoung, Janet

    1983-01-01

    Discusses the nature of pulse voltammetry, indicating that its widespread use arises from good sensitivity and detection limits and from ease of application and low cost. Provides analytical and mechanistic applications of the procedure. (JN)

  10. Radiolysis driven changes to oxide stability during irradiation-corrosion of 316L stainless steel in high temperature water

    Science.gov (United States)

    Raiman, Stephen S.; Bartels, David M.; Was, Gary S.

    2017-09-01

    316L stainless steel samples were irradiated with a proton beam while simultaneously exposed to high temperature water with hydrogen (320 °C, 3 wppm H2, neutral pH) to study the effect of radiation on corrosion. The inner oxides on irradiated samples were found to be depleted in chromium when compared to the inner oxides on unirradiated samples exposed to the same conditions. Additionally, hematite was found on the oxide surfaces of irradiated samples, but not on unirradiated samples. Sample areas which were not directly irradiated but were exposed to the flow of irradiated water also exhibited chromium-deficient inner oxides and had hematite on their surfaces, so it is concluded that water radiolysis is the primary driver of both effects. Thermodynamic calculations and radiolysis modeling were used to show that radiolytic production of hydrogen peroxide was sufficient to raise corrosion potential high enough to cause the dissolution of chromium-rich spinel oxides which make up the inner oxide layer on stainless steel in high temperature water.

  11. On the possibility of galactic cosmic ray-induced radiolysis-powered life in subsurface environments in the Universe.

    Science.gov (United States)

    Atri, Dimitra

    2016-10-01

    Photosynthesis is a mechanism developed by terrestrial life to utilize the energy from photons of solar origin for biological use. Subsurface regions are isolated from the photosphere, and consequently are incapable of utilizing this energy. This opens up the opportunity for life to evolve alternative mechanisms for harvesting available energy. Bacterium Candidatus Desulforudis audaxviator, found 2.8 km deep in a South African mine, harvests energy from radiolysis, induced by particles emitted from radioactive U, Th and K present in surrounding rock. Another radiation source in the subsurface environments is secondary particles generated by galactic cosmic rays (GCRs). Using Monte Carlo simulations, it is shown that it is a steady source of energy comparable to that produced by radioactive substances, and the possibility of a slow metabolizing life flourishing on it cannot be ruled out. Two mechanisms are proposed through which GCR-induced secondary particles can be utilized for biological use in subsurface environments: (i) GCRs injecting energy in the environment through particle-induced radiolysis and (ii) organic synthesis from GCR secondaries interacting with the medium. Laboratory experiments to test these hypotheses are also proposed. Implications of these mechanisms on finding life in the Solar System and elsewhere in the Universe are discussed.

  12. Radiolysis of C5-BTBP in cyclohexanone irradiated in the absence and presence of an aqueous phase

    Energy Technology Data Exchange (ETDEWEB)

    Fermvik, A.; Aneheim, E.; Kvicalova, M.; Ekberg, C. [Chalmers Univ. of Technology, Goeteborg (Sweden). Nuclear Chemistry; Chalmers Univ. of Technology, Goeteborg (Sweden). Industrial Materials Recycling; Gruener, B.; Hajkova, Z. [Academy of Sciences of the Czech Republic, Husinec-Rez (Czech Republic). Inst. of Inorganic Chemistry

    2012-07-01

    Spent nuclear fuel contains many highly radioactive species; hence solvents used in reprocessing will be subjected to radiolysis. In this study, solvents containing one of the BTBP molecules intended for the separation of trivalent actinides and lanthanides, the so called C5-BTBP, have been subjected to radiolysis and hydrolysis. We present here that this compound shows a dramatic decrease in both distribution ratios and separation factor when irradiated with higher doses up to 50 kGy; particularly in the presence of an aqueous phase. Furthermore, fast hydrolytic degradation is observed, which significantly contributes to the overall degree of decomposition. This is supported by speciation studies performed by HPLC and LC-MS methods. Proposed structures of the highest-yield degradation products are presented and they seem to confirm previously drawn structures for these products. From these studies it can be concluded that the presence of nitric acid or nitrate during irradiation leads to higher content of species containing keto groups. (orig.)

  13. Examination of the effect of alpha radiolysis on plutonium(V) sorption to quartz using multiple plutonium isotopes.

    Science.gov (United States)

    Hixon, Amy E; Arai, Yuji; Powell, Brian A

    2013-08-01

    The objective of this research was to determine if radiolysis at the mineral surface was a plausible mechanism for surface-mediated reduction of plutonium. Batch sorption experiments were used to monitor the amount of plutonium sorbed to high-purity quartz as a function of time, pH, and total alpha radioactivity. Three systems were prepared using both (238)Pu and (242)Pu in order to increase the total alpha radioactivity of the mineral suspensions while maintaining a constant plutonium concentration. The fraction of sorbed plutonium increased with increasing time and pH regardless of the total alpha radioactivity of the system. Increasing the total alpha radioactivity of the solution had a negligible effect on the sorption rate. This indicated that surface-mediated reduction of Pu(V) in these systems was not due to radiolysis. Additionally, literature values for the Pu(V) disproportionation rate constant did not describe the experimental results. Therefore, Pu(V) disproportionation was also not a main driver for surface-mediated reduction of plutonium. Batch desorption experiments and X-ray absorption near edge structure spectroscopy were used to show that Pu(IV) was the dominant oxidation state of sorbed plutonium. Thus, it appears that the observed surface-mediated reduction of Pu(V) in the presence of high-purity quartz was based on the thermodynamic favorability of a Pu(IV) surface complex.

  14. Room temperature synthesis of Ni-based alloy nanoparticles by radiolysis.

    Energy Technology Data Exchange (ETDEWEB)

    Nenoff, Tina Maria; Berry, Donald T.; Lu, Ping; Leung, Kevin; Provencio, Paula Polyak; Stumpf, Roland Rudolph; Huang, Jian Yu; Zhang, Zhenyuan

    2009-09-01

    Room temperature radiolysis, density functional theory, and various nanoscale characterization methods were used to synthesize and fully describe Ni-based alloy nanoparticles (NPs) that were synthesized at room temperature. These complementary methods provide a strong basis in understanding and describing metastable phase regimes of alloy NPs whose reaction formation is determined by kinetic rather than thermodynamic reaction processes. Four series of NPs, (Ag-Ni, Pd-Ni, Co-Ni, and W-Ni) were analyzed and characterized by a variety of methods, including UV-vis, TEM/HRTEM, HAADF-STEM and EFTEM mapping. In the first focus of research, AgNi and PdNi were studied. Different ratios of Ag{sub x}- Ni{sub 1-x} alloy NPs and Pd{sub 0.5}- Ni{sub 0.5} alloy NP were prepared using a high dose rate from gamma irradiation. Images from high-angle annular dark-field (HAADF) show that the Ag-Ni NPs are not core-shell structure but are homogeneous alloys in composition. Energy filtered transmission electron microscopy (EFTEM) maps show the homogeneity of the metals in each alloy NP. Of particular interest are the normally immiscible Ag-Ni NPs. All evidence confirmed that homogeneous Ag-Ni and Pd-Ni alloy NPs presented here were successfully synthesized by high dose rate radiolytic methodology. A mechanism is provided to explain the homogeneous formation of the alloy NPs. Furthermore, studies of Pd-Ni NPs by in situ TEM (with heated stage) shows the ability to sinter these NPs at temperatures below 800 C. In the second set of work, CoNi and WNi superalloy NPs were attempted at 50/50 concentration ratios using high dose rates from gamma irradiation. Preliminary results on synthesis and characterization have been completed and are presented. As with the earlier alloy NPs, no evidence of core-shell NP formation occurs. Microscopy results seem to indicate alloying occurred with the CoNi alloys. However, there appears to be incomplete reduction of the Na{sub 2}WO{sub 4} to form the W

  15. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  16. Radiolysis products and sensory properties of electron-beam-irradiated high-barrier food-packaging films containing a buried layer of recycled low-density polyethylene.

    Science.gov (United States)

    Chytiri, S D; Badeka, A V; Riganakos, K A; Kontominas, M G

    2010-04-01

    The aim was to study the effect of electron-beam irradiation on the production of radiolysis products and sensory changes in experimental high-barrier packaging films composed of polyamide (PA), ethylene-vinyl alcohol (EVOH) and low-density polyethylene (LDPE). Films contained a middle buried layer of recycled LDPE, while films containing 100% virgin LDPE as the middle buried layer were taken as controls. Irradiation doses ranged between zero and 60 kGy. Generally, a large number of radiolysis products were produced during electron-beam irradiation, even at the lower absorbed doses of 5 and 10 kGy (approved doses for food 'cold pasteurization'). The quantity of radiolysis products increased with irradiation dose. There were no significant differences in radiolysis products identified between samples containing a recycled layer of LDPE and those containing virgin LDPE (all absorbed doses), indicating the 'functional barrier' properties of external virgin polymer layers. Sensory properties (mainly taste) of potable water were affected after contact with irradiated as low as 5 kGy packaging films. This effect increased with increasing irradiation dose.

  17. Radiolysis ob benzene, toluene and phenol aqueous solutions utilizing high energy electron beam; Radiolisis de benceno, tolueno y fenol en solucion acuosa utilizando haces de electrones

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Vanderhaghen, D.E

    1998-12-31

    In a search for solutions to environmental pollution problems, radiolysis has proved to be an innovative technique for the removal of organic chemical pollutants in aqueous solution. Radiolysis has shown many advantages over many other techniques, as highly reactive species formed in water by ionizing radiation oxidize organic pollutants breaking down organic molecules to final simple products by oxidation to carbon dioxide and water in a complete oxidation. Our work consisted in doing some experiments in radiolysis with simulated polluted water to help us understand this technique and also develop, in a near future, a project for large scale water treatment. Our project includes the application of a Pelletron type Mexican made Electron Accelerator, which will affirm its capability and usefulness in performing investigation in this field of study. Experiments consisted in treating benzene, toluene and phenol aqueous solutions with an Electron Beam (0.48-0.55 MeV; 24 {mu}A). Two concentrations were used for each compound: 5 and 20 ppm (mg/l) for benzene and toluene; 10 and 50 ppm for phenol. Solutions were prepared with pure, mineral free water and two different p H (5.9), in order to study the effect of concentration and p H on removal efficiency, but avoiding the interference of radical scavengers. Results obtained coincide with the ones reported by Cooper, Nickelsen and Kurucz; highly efficient removal was achieved for benzene (>99.8%), toluene (>98.0%) and phenol (>88%). There was no visible important effect of p H on radiolysis efficiency for benzene nor toluene, phenol however, showed lower removal efficiency in acidic conditions. Concentration of aqueous solutions, nevertheless, did show an important effect at low doses for phenol. Results obtained reveal the importance of this technique in water pollution control and water remedial as expressed by Cooper, Nickelsen and Kurucz, who have studied radiolysis of organic compounds and apply this technique in water

  18. Non-equilibrium Thermodynamic Dissolution Theory for Multi-Component Solid/Liquid Surfaces Involving Surface Adsorption and Radiolysis Kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Stout, R B

    2001-04-01

    A theoretical expression is developed for the dissolution rate response for multi-component radioactive materials that have surface adsorption kinetics and radiolysis kinetics when wetted by a multi-component aqueous solution. An application for this type of dissolution response is the performance evaluation of multi-component spent nuclear fuels (SNFs) for long term interim storage and for geological disposition. Typically, SNF compositions depend on initial composition, uranium oxide and metal alloys being most common, and on reactor burnup which results in a wide range of fission product and actinide concentrations that decay by alpha, beta, and gamma radiation. These compositional/burnup ranges of SNFs, whether placed in interim storage or emplaced in a geologic repository, will potentially be wetted by multi-component aqueous solutions, and these solutions may be further altered by radiolytic aqueous species due to three radiation fields. The solid states of the SNFs are not thermodynamically stable when wetted and will dissolve, with or without radiolysis. The following development of a dissolution theory is based on a non-equilibrium thermodynamic analysis of energy reactions and energy transport across a solid-liquid phase change discontinuity that propagates at a quasi-steady, dissolution velocity. The integral form of the energy balance equation is used for this spatial surface discontinuity analysis. The integral formulation contains internal energy functional of classical thermodynamics for both the SNFs' solid state and surface adsorption species, and the adjacent liquid state, which includes radiolytic chemical species. The steady-state concentrations of radiolytic chemical species are expressed by an approximate analysis of the decay radiation transport equation. For purposes of illustration a modified Temkin adsorption isotherm was assumed for the surface adsorption kinetics on an arbitrary, finite area of the solid-liquid dissolution interface

  19. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    DEFF Research Database (Denmark)

    Draganic, Z.D.; Negrón-Mendoza, A.; Sehested, K.;

    1991-01-01

    Oxygen-free aqueous solutions of 0.05 mol dm-3 ammonium and sodium bicarbonate were studied after receiving various doses of Co-60 gammas (0.01-400 kGy) or 0.5-20 Gy pulses of 10 Mev electrons. Formate and oxalate were found to be the main radiolytic products, in addition to trace amounts of form...

  20. Pulsed thermoelectricity

    Science.gov (United States)

    Apostol, M.; Nedelcu, M.

    2010-07-01

    A special mechanism of thermoelectric transport is described, consisting of pulses of charge carriers which "fly" periodically through the external circuit from the hot end of the sample to the cold end, with a determined duration of the "on" and "off" times of the electric contacts, while maintaining continuously the thermal contacts. It is shown that such a "resonant" ideal thermogenerator may work cyclically, with the same efficiency quotient as the ideal efficiency quotient of the thermoelectric devices operated in the usual stationary transport regime but the electric flow and power are increased, as a consequence of the concentration of the charge carriers on pulses of small spatial extent. The process is reversible, in the sense that it can be operated either as a thermoelectric generator or as an electrothermal cooler.

  1. [Concentrations, distribution characteristics and electron beam radiolysis degradation of PCDD/Fs in waste water from a paper mill].

    Science.gov (United States)

    Qing, Xian; Huang, Jin-Qiong; Yu, Xiao-Wei; Zhang, Su-Kun; Yang, Yan-Yan; Ren, Ming-Zhong; Wen, Yu-Long

    2014-07-01

    Concentrations and distribution characteristics of 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofurans (2,3,7,8-PCDD/Fs) were analyzed in waste water from a paper mill. And concentrations of 2,3,7,8-PCDD/Fs in waste water before and after electron beam irradiation with different doses were compared. The feasibility, mechanism and rates of 2,3,7,8-PCDD/Fs degradation were discussed. The PCDD/Fs concentrations and corresponding I-TEQ (toxic equivalent quantity) values were 239 pg x L(-1) and 41.0 pg x L(-1), respectively, in the waste water. The concentrations of total 2,3,7,8-PCDD/Fs decreased after electron beam radiolysis at a dose of 30 kGy and 60 kGy with degradation rates of 5.27% and 23.6%, respectively.

  2. OH-radical induced degradation of hydroxybenzoic- and hydroxycinnamic acids and formation of aromatic products-A gamma radiolysis study

    Energy Technology Data Exchange (ETDEWEB)

    Krimmel, Birgit; Swoboda, Friederike [University of Vienna, Department of Nutritional Sciences, Section Radiation Biology (Austria); Solar, Sonja, E-mail: sonja.solar@univie.ac.a [University of Vienna, Department of Nutritional Sciences, Section Radiation Biology (Austria); Reznicek, Gottfried [Department of Pharmacognosy, Althanstrasse 14, A-1090 Vienna (Austria)

    2010-12-15

    The OH-radical induced degradation of hydroxybenzoic acids (HBA), hydroxycinnamic acids (HCiA) and methoxylated derivatives, as well as of chlorogenic acid and rosmarinic acid was studied by gamma radiolysis in aerated aqueous solutions. Primary aromatic products resulting from an OH-radical attachment to the ring (hydroxylation), to the position occupied by the methoxyl group (replacement -OCH{sub 3} by -OH) as well as to the propenoic acid side chain of the cinnamic acids (benzaldehyde formations) were analysed by HPLC-UV and LC-ESI-MS. A comparison of the extent of these processes is given for 3,4-dihydroxybenzoic acid, vanillic acid, isovanillic acid, syringic acid, cinnamic acid, 4-hydroxycinnamic acid, caffeic acid, ferulic acid, isoferulic acid, chlorogenic acid, and rosmarinic acid. For all cinnamic acids and derivatives benzaldehydes were significant oxidation products. With the release of caffeic acid from chlorogenic acid the cleavage of a phenolic glycoside could be demonstrated. Reaction mechanisms are discussed.

  3. OH-radical induced degradation of hydroxybenzoic- and hydroxycinnamic acids and formation of aromatic products—A gamma radiolysis study

    Science.gov (United States)

    Krimmel, Birgit; Swoboda, Friederike; Solar, Sonja; Reznicek, Gottfried

    2010-12-01

    The OH-radical induced degradation of hydroxybenzoic acids (HBA), hydroxycinnamic acids (HCiA) and methoxylated derivatives, as well as of chlorogenic acid and rosmarinic acid was studied by gamma radiolysis in aerated aqueous solutions. Primary aromatic products resulting from an OH-radical attachment to the ring (hydroxylation), to the position occupied by the methoxyl group (replacement -OCH 3 by -OH) as well as to the propenoic acid side chain of the cinnamic acids (benzaldehyde formations) were analysed by HPLC-UV and LC-ESI-MS. A comparison of the extent of these processes is given for 3,4-dihydroxybenzoic acid, vanillic acid, isovanillic acid, syringic acid, cinnamic acid, 4-hydroxycinnamic acid, caffeic acid, ferulic acid, isoferulic acid, chlorogenic acid, and rosmarinic acid. For all cinnamic acids and derivatives benzaldehydes were significant oxidation products. With the release of caffeic acid from chlorogenic acid the cleavage of a phenolic glycoside could be demonstrated. Reaction mechanisms are discussed.

  4. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  5. Two step formation of metal aggregates by surface X-ray radiolysis under Langmuir monolayers: 2D followed by 3D growth

    Directory of Open Access Journals (Sweden)

    Smita Mukherjee

    2015-12-01

    Full Text Available In order to form a nanostructured metallic layer below a Langmuir monolayer, radiolysis synthesis was carried out in an adapted geometry that we call surface X-ray radiolysis. In this procedure, an X-ray beam produced by a synchrotron beamline intercepts the surface of an aqueous metal-ion solution covered by a Langmuir monolayer at an angle of incidence below the critical angle for total internal reflection. Underneath the organic layer, the X-ray beam induces the radiolytic synthesis of a nanostructured metal–organic layer whose ultrathin thickness is defined by the vertical X-ray penetration depth. We have shown that increasing the X-ray flux on the surface, which considerably enhances the kinetics of the silver layer formation, results in a second growth regime of silver nanocrystals. Here the formation of the oriented thin layer is followed by the appearance of a 3D powder of silver clusters.

  6. An apparatus for the study of high temperature water radiolysis in a nuclear reactor: calibration of dose in a mixed neutron/gamma radiation field.

    Science.gov (United States)

    Edwards, Eric J; Wilson, Paul P H; Anderson, Mark H; Mezyk, Stephen P; Pimblott, Simon M; Bartels, David M

    2007-12-01

    The cooling water of nuclear reactors undergoes radiolytic decomposition induced by gamma, fast electron, and neutron radiation in the core. To model the process, recombination reaction rates and radiolytic yields for the water radical fragments need to be measured at high temperature and pressure. Yields for the action of neutron radiation are particularly hard to determine independently because of the beta/gamma field also present in any reactor. In this paper we report the design of an apparatus intended to measure neutron radiolysis yields as a function of temperature and pressure. A new methodology for separation of neutron and beta/gamma radiolysis yields in a mixed radiation field is proposed and demonstrated.

  7. LC-MS analysis in the e-beam and gamma radiolysis of metoprolol tartrate in aqueous solution: Structure elucidation and formation mechanism of radiolytic products

    Energy Technology Data Exchange (ETDEWEB)

    Slegers, Catherine [Unite d' Analyse Chimique et Physico-chimique des Medicaments, Universite Catholique de Louvain, CHAM 72.30, Avenue E. Mounier, 72, B-1200, Brussels (Belgium)]. E-mail: catherine.slegers@skynet.be; Maquille, Aubert [Unite d' Analyse Chimique et Physico-chimique des Medicaments, Universite Catholique de Louvain, CHAM 72.30, Avenue E. Mounier, 72, B-1200, Brussels (Belgium); Deridder, Veronique [Unite d' Analyse Chimique et Physico-chimique des Medicaments, Universite Catholique de Louvain, CHAM 72.30, Avenue E. Mounier, 72, B-1200, Brussels (Belgium); Sonveaux, Etienne [Unite de Chimie Pharmaceutique et de Radiopharmacie, Universite Catholique de Louvain, Brussels (Belgium); Habib Jiwan, Jean-Louis [Laboratoire de Spectrometrie de Masse, Universite Catholique de Louvain, Louvain-La-Neuve (Belgium); Tilquin, Bernard [Unite d' Analyse Chimique et Physico-chimique des Medicaments, Universite Catholique de Louvain, CHAM 72.30, Avenue E. Mounier, 72, B-1200, Brussels (Belgium)

    2006-09-15

    E-beam and gamma products from the radiolysis of aqueous solutions of ({+-})-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of ({+-})-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.

  8. Excimer Laser Pulse Compress With Pulse Feedback

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>To attain a shorter laser pulse, a compressing technique called pulse feedback was developed from the saturation gain switch applied to the amplification in a discharge pumping excimer laser cavity. It can

  9. Pulsed Optics

    Science.gov (United States)

    Hirlimann, C.

    Optics is the field of physics which comprises knowledge on the interaction between light and matter. When the superposition principle can be applied to electromagnetic waves or when the properties of matter do not depend on the intensity of light, one speaks of linear optics. This situation occurs with regular light sources such as light bulbs, low-intensity light-emitting diodes and the sun. With such low-intensity sources the reaction of matter to light can be characterized by a set of parameters such as the index of refraction, the absorption and reflection coefficients and the orientation of the medium with respect to the polarization of the light. These parameters depend only on the nature of the medium. The situation changed dramatically after the development of lasers in the early sixties, which allowed the generation of light intensities larger than a kilowatt per square centimeter. Actual large-scale short-pulse lasers can generate peak powers in the petawatt regime. In that large-intensity regime the optical parameters of a material become functions of the intensity of the impinging light. In 1818 Fresnel wrote a letter to the French Academy of Sciences in which he noted that the proportionality between the vibration of the light and the subsequent vibration of matter was only true because no high intensities were available. The intensity dependence of the material response is what usually defines nonlinear optics.

  10. Oxidizing dissolution of spent MOX47 fuel subjected to water radiolysis: Solution chemistry and surface characterization by Raman spectroscopy

    Science.gov (United States)

    Jégou, C.; Caraballo, R.; De Bonfils, J.; Broudic, V.; Peuget, S.; Vercouter, T.; Roudil, D.

    2010-04-01

    The mechanisms of oxidizing dissolution of spent MOX fuel (MIMAS TU2®) subjected to water radiolysis were investigated experimentally by leaching spent MOX47 fuel samples in pure water at 25 °C under different oxidizing conditions (with and without external gamma irradiation); the leached surfaces were characterized by Raman spectroscopy. The highly oxidizing conditions resulting from external gamma irradiation significantly increased the concentration of plutonium (Pu(V)) and uranium (U(VI)) compared with a benchmark experiment (without external irradiation). The oxidation behavior of the plutonium-enriched aggregates differed significantly from that of the UO 2 matrix after several months of leaching in water under gamma irradiation. The plutonium in the aggregates appears to limit fuel oxidation. The only secondary phases formed and identified to date by Raman spectroscopy are uranium peroxides that generally precipitate on the surface of the UO 2 grains. Concerning the behavior of plutonium, solution analysis results appear to be compatible with a conventional explanation based on an equilibrium with a Pu(OH) 4(am) phase. The fission product release - considered as a general indicator of matrix alteration - from MOX47 fuel also increases under external gamma irradiation and a change in the leaching mode is observed. Diffusive leaching was clearly identified, coinciding with the rapid onset of steady-state actinide concentrations in the bulk solution.

  11. Programmable pulse generator

    CERN Document Server

    Xue Zhi Hua; Duan Xiao Hui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  12. Investigation of molecular mechanisms in photodynamic action and radiobiology with nanosecond flash photolysis and pulse radiolysis. Progress report, October 1, 1980-September 30, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Grossweiner, L I

    1981-06-01

    Laser flash photolysis experiments have led to a new mechanism for the ultraviolet photolysis of aqueous tryptophan (Trp), indole (Ind) and certain indole derivatives. Excitation at 265 nm leads to photoionization via a pre-fluorescent state with thermal activation. A new formula is proposed for predicting enzyme inactivation quantum yields. The predictions are in good agreement with measurements on six important enzymes at 254 nm and 280 nm. Kinetics models have been developed and tested for important stages in the photosensitization of DNA to near-ultraviolet radiation by furocoumarin compounds currently used for PUVA therapy (psoralen plus UV-A) of psoriasis and other human skin diseases. Experiments on photobinding of psoralen (Ps) and 8-methoxypsoralen (8-MOP) to calf thymus DNA are consistent with the assumption that equilibrium dark complexing of the furocoumarin to the DNA is a precondition for the formation of covalent monoadducts and cross-links. Singlet oxygen generation by furocoumarins has been investigated with liposomes and human erythrocytes (rbc). Results obtained with 3-carbethoxypsoralen (3-CPs), an experimental alternate PUVA sensitizer claimed to be non-tumorigenic, show that 3-CPs interacts with liposome and rbc membranes in the dark. Studies on photosensitization of egg lecithin liposomes by methylene blue (MB) incorporated in the membrane have led to the new result that membrane lysis is a two-stage process. The first stage induced by red light irradiation leads to membrane damage initiated by O/sub 2/*. Membrane lysis takes place in the dark, second stage under the action of mild hydrodynamic stress, such as slow gas bubbling.

  13. Investigation of molecular mechanisms in photodynamic action and radiobiology with nanosecond flash photolysis and pulse radiolysis. Progress report, July 1, 1975--June 30, 1976

    Energy Technology Data Exchange (ETDEWEB)

    Grossweiner, L.I.

    1976-03-01

    Flash photolysis studies have shown that exposed tyrosyl or tryptophyl residues of enzymes are photoionized at approximately the same quantum efficiency as the aqueous amino acids. Comparisons with permanent damage indicate that this primary process contributes to inactivation when a photolyzed aromatic residue is essential or is located adjacent to a catalytic, non-chromoporic residue. Studies on sensitization by the phototherapeutic drug, 8-methoxypsoralen (8-MOP), show the triplet state can lead to singlet oxygen generation and that weak binding to poly (dA-dT) suppresses this process. 8-MOP was found to be potent sensitizer of yeast photoinactivation with negligible post-irradiation recovery. Spinlable ESR measurements made on yeast cells after photodynamic treatment show that the membrane damage generated by the penetrating dye Toluidine Blue 0 is more extensive than the external dye, Eosin Y. In related ionizing radiation studies, it was found that 8-MOP is an anoxic radiosensitizer of T7 phage, attributed to enhancement of crosslinks; that complexing of eosin to lysozyme sensitizes the enzyme to oxidizing radicals; that the reactions of Br/sub 2//sup -/ and (CNS)/sub 2//sup -/ with tryptophan generate the same initial radical as uv-excited photoionization.

  14. The oxidation of chromium(III) by hydroxyl radical in alkaline solution. A stopped-flow and pre-mix pulse radiolysis study

    DEFF Research Database (Denmark)

    Zhao, Zhongwei; Rush, J.D.; Holcman, J.

    1995-01-01

    The pK(a) for the equilibrium Cr(III)(H2O)3(OH)3(OH)3 reversible Cr(III)(H2O)2(OH)4- + H+ was determined to be 12.8 at 25-degrees-C. The dimerization of the two monomeric forms was studied in alkaline solutions using the stopped-flow method: k2[Cr(III)(H2O)3(OH)3 + Cr(III)(H2O)3(OH)3] = (2.5 +/- ......(VI)-(O-Cr(III))n]. Furthermore, a second-order reaction between two Cr(IV) monomers to yield a species which may be either a (Cr)2IV,IV or a (Cr)2III,V mixed-valence dimer was observed. The corresponding spectra in both the UV and visible range were determined....

  15. The oxidation of chromium(III) by hydroxyl radical in alkaline solution. A stopped-flow and pre-mix pulse radiolysis study

    DEFF Research Database (Denmark)

    Zhao, Zhongwei; Rush, J.D.; Holcman, J.

    1995-01-01

    The pK(a) for the equilibrium Cr(III)(H2O)3(OH)3(OH)3 reversible Cr(III)(H2O)2(OH)4- + H+ was determined to be 12.8 at 25-degrees-C. The dimerization of the two monomeric forms was studied in alkaline solutions using the stopped-flow method: k2[Cr(III)(H2O)3(OH)3 + Cr(III)(H2O)3(OH)3] = (2.5 +/- ......(VI)-(O-Cr(III))n]. Furthermore, a second-order reaction between two Cr(IV) monomers to yield a species which may be either a (Cr)2IV,IV or a (Cr)2III,V mixed-valence dimer was observed. The corresponding spectra in both the UV and visible range were determined....

  16. Effect of electron-withdrawing power of the substituted group on ${}^{\\bullet}$OH radical reaction with substituted aryl sulphides: A pulse radiolysis study

    Indian Academy of Sciences (India)

    Hari Mohan

    2002-12-01

    In neutral aqueous solution of (phenylthio)acetic acid, hydroxyl radical is observed to react with a bimolecular rate constant of 7.2 × 109 dm3 mol-1 s-1 and the transient absorption bands are assigned to ${}^{\\bullet}$OH radical addition to benzene and sulphur with a rough estimated values of 50 and 40% respectively. The reaction of the ${}^{\\bullet}$OH radical with diphenyl sulphide ( = 4.3 × 108 dm3 mol-1 s-1) is observed to take place with formation of solute radical cation, OH-adduct at sulphur and benzene with estimated values of about 12, 28 and 60% respectively. The transient absorption bands observed on reaction of ${}^{\\bullet}$OH radical, in neutral aqueous solution of 4-(methylthio) phenyl acetic acid, are assigned to solute radical cation (max = 550 and 730 nm), OH-adduct at sulphur (max = 360 nm) and addition at benzene ring (max = 320 nm). The fraction of ${}^{\\bullet}$OH radical reacting to form solute radical cation is observed to depend on the electron-withdrawing power of substituted group. In acidic solutions, depending on the concentration of acid and electron-withdrawing power, solute radical cation is the only transient species formed on reaction of ${}^{\\bullet}$OH radical with the sulphides studied.

  17. Pulse radiolysis study of CF3CFHO2 radicals in the gas phase at 298 K

    DEFF Research Database (Denmark)

    Wallington, T.J.; Nielsen, O.J.

    1991-01-01

    .34 +/- 1.08) x 10(-18) cm2 molecule-1. Errors represent statistical (2-sigma) and our estimate of potential systematic errors (15%). The rate constant for the reaction of CF3CFHO2 radicals with NO was then determined to be k6 = (1.28 +/- 0.36) x 10(-11) cm3 molecule-1 s-1. Errors represent statistical (2......-sigma) and our estimate of potential systematic errors (20%). As part of this work the rate constant for the reaction of F atoms with CF3CFH2 was measured and found to be (3.6 +/- 0.9) x 10(-12) cm3 molecules-1 s-1 at 298 K. Errors are 2-sigma.......The ultraviolet absorption spectrum of the CF3CHFO2 radical, and the kinetics of its reaction with NO, have been studied in the gas phase at 298 K. Absorption cross sections were quantified over the wavelength range 220-290 nm. The measured cross section at 220 nm is sigma-CF3CHFO2 (220 nm) = (5...

  18. Investigation of molecular mechanisms in photodynamic action and radiobiology with nanosecond flash photolysis and pulse radiolysis. Progress report, July 1, 1976--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Grossweiner, L.I.

    1977-06-01

    Laser flash photolysis investigations on aromatic amino acids and proteins have demonstrated that monophotonic electron ejection is the major initial act, leading to e/sup -//sub aq/ and the corresponding aromatic radicals, followed by back reactions limited by available e/sup -//sub aq/ scavengers. Results with ribonuclease A, lysozyme and carboxypeptidase A have led to information about the relationship of the photoionization efficiency of aromatic residues to the microenvironment. Measurements on the decay kinetics of photoelectrons have shown that the lifetimes and their dependence on scavenger concentrations and dose are inconsistent with homogeneous reactions. A new theory is proposed in which the photoelectron diffuses through the medium as a quasi-free particle, where original pair-recombination competes with scavenging and pair-pair interactions. This theory is in good agreement with laser flash photolysis studies on I/sup -/, FE(CN)/sub 6//sup 4 -/, tryptophan and tyrosine and consistent with earlier photochemical scavenging measurements. The general analysis of radition sensitivity has been extended to suspensions of large biological targets, such as vesicles, viruses and cells, particularly where the radical diffusion length is smaller than or comparable to the collision radius. The development is exemplified with new work on inactivation of T7 bacteriophag by 25 MeV electrons and photodynamic inactivation of Saccharomyces cerevisiae. Detailed studies on yeast have shown that the sensitivity to singlet oxygen attack depends on the temperature and the culture growth phase. Spin label ESR measurements indicate that he conditions of low photosensitivity parallel low membrane fluidity.

  19. The influence of radical transfer and scavenger materials in various concentrations on the gamma radiolysis of phenol

    Science.gov (United States)

    Kozmér, Zsuzsanna; Takács, Erzsébet; Wojnárovits, László; Alapi, Tünde; Hernádi, Klára; Dombi, András

    2016-07-01

    The influence of a radical scavenger (tert-butanol (t-BuOH)) and two radical transfer materials (formic acid (HCOOH) and formate anion (HCOO-)) on the radical set during radiolysis of a simple model compound, phenol (PhOH, 1.0×10-4 mol L-1) is discussed in this study. PhOH solutions were irradiated with γ-rays, in the presence of 1.0×10-3, 5.0×10-2 and 5.0×10-1 mol L-1t-BuOH, HCOOH or HCOONa under deoxygenated and O2-saturated reaction conditions. The rate of transformation of PhOH increased significantly in the presence of dissolved O2. The radical transfer or scavenger materials used reduced the rates of transformation of PhOH in O2-saturated solutions to a similar degree. The simultaneous presence of O2 and the organic additives in excess proportionally to PhOH results in the conversion of the radical set to less reactive intermediates (t-•OOBuOH, HO2• or O2•-), which made minor contribution to the transformation of PhOH. Under oxygenated conditions, t-BuOH and HCOOH in low concentrations slightly promoted the degradation, as opposed to HCOO- which reduced it. However, using higher additive concentrations, their competitive reactions for the primary intermediates came into prominence, thus they reduced the efficiency of PhOH decomposition. HO2• and O2•-, and also the carbon-centred radicals formed (order of their reactivity t-•BuOH>•COOH> CO2•-) have only a minor contribution to the degradation of PhOH, and the reactions of •OH+PhOH and eaq-+PhOH are the significant processes.

  20. Temperature Dependence of the Primary Species Yields of Liquid Water Radiolysis by 0.8-MeV Fast Neutrons

    Directory of Open Access Journals (Sweden)

    S.L. Butarbutar

    2016-04-01

    Full Text Available The yields of species such as e-aq, H•, •OH, H2 and H2O2, formed from the radiolysis of neutral liquid water by the incidence of 0.8-MeV neutrons at temperatures between 25 and 350°C, were calculated by using Monte Carlo simulations. The slowing down of these neutrons through elastic scattering produced recoil protons elastically of ~0.5057, 0.186, and 0.0684 MeV which had linear energy transfers (LETs of ~40, 67 and 76 keV/µm, respectively, at 25°C. The effects of neutron radiation can be predicted based on the contribution of those first three recoil protons by neglecting the radiation effects due to oxygen ion recoils. Then, the fast neutron yields could be estimated by summing the yields of contributing protons after corresponding weightings were used according to their energy. In this work, yields were calculated at 10-7 and 10-6 s after incidence of neutron radiation in water at the aforementioned temperature range. Overall, there is a reasonably good agreement between our calculated and existing experimental G-values for the entire temperature range. However, we proposed an hypothesis that the not very significant difference between experimental data and our calculated data is due to the different measuring time used in obtaining the experimental data as compared to the ones used in our calculation. Our computed yields for 0.8-MeV fast neutron radiation show an essentially similar temperature dependences over the range of temperature studied with 2-MeV fast neutron and low-LET radiation, but with lower values for yields of free radicals and higher values for molecular yields.

  1. Modeling the radiolysis of supercritical water by fast neutrons: density dependence of the yields of primary species at 400°c.

    Science.gov (United States)

    Butarbutar, Sofia Loren; Meesungnoen, Jintana; Guzonas, David A; Stuart, Craig R; Jay-Gerin, Jean-Paul

    2014-12-01

    A reliable understanding of radiolysis processes in supercritical water (SCW)-cooled reactors is crucial to developing chemistry control strategies that minimize the corrosion and degradation of materials. However, directly measuring the chemistry in reactor cores is difficult due to the extreme conditions of high temperature and pressure and mixed neutron and gamma-radiation fields, which are incompatible with normal chemical instrumentation. Thus, chemical models and computer simulations are an important route of investigation for predicting the detailed radiation chemistry of the coolant in a SCW reactor and the consequences for materials. Surprisingly, information on the fast neutron radiolysis of water at high temperatures is limited, and even more so for fast neutron irradiation of SCW. In this work, Monte Carlo simulations were used to predict the G values for the primary species e(-)aq, H(•), H2, (•)OH and H2O2 formed from the radiolysis of pure, deaerated SCW (H2O) by 2 MeV monoenergetic neutrons at 400°C as a function of water density in the range of ∼0.15-0.6 g/cm(3). The 2 MeV neutron was taken as representative of a fast neutron flux in a reactor. For light water, the moderation of these neutrons after knock-on collisions with water molecules generated mostly recoil protons of 1.264, 0.465, 0.171 and 0.063 MeV. Neglecting oxygen ion recoils and assuming that the most significant contribution to the radiolysis came from these first four recoil protons, the fast neutron yields were estimated as the sum of the G values for these protons after appropriate weightings were applied according to their energy. Calculated yields were compared with available experimental data and with data obtained for low-LET radiation. Most interestingly, the reaction of H(•) atoms with water was found to play a critical role in the formation yields of H2 and (•)OH at 400°C. Recent work has underscored the potential importance of this reaction above 200°C, but its

  2. Radiolysis of Salts and Long-Term Storage Issues for Both Pure and Impure PuO{sub 2} Materials in Plutonium Storage Containers

    Energy Technology Data Exchange (ETDEWEB)

    Lav Tandon

    2000-05-01

    The Material Identification and Surveillance (MIS) project sponsored a literature search on the effects of radiation on salts, with focus on alkali chlorides. The goal of the survey was to provide a basis for estimating the magnitude of {alpha} radiation effects on alkali chlorides that can accompany plutonium oxide (PuO{sub 2}) into storage. Chloride radiolysis can yield potentially corrosive gases in plutonium storage containers that can adversely affect long-term stability. This literature search was primarily done to provide a tutorial on this topic, especially for personnel with nonradiation chemistry backgrounds.

  3. Radial pulse (image)

    Science.gov (United States)

    ... heart. The arteries are the vessels with the "pulse", a rhythmic pushing of the blood in the ... a refilling of the heart chamber. To determine heart rate, one feels the beats at a pulse point ...

  4. Wrist pulse (image)

    Science.gov (United States)

    To measure the pulse at the wrist, place the index and middle finger over the underside of the opposite wrist, below the base ... firmly with flat fingers until you feel the pulse in the radial artery.

  5. Formation of nitrogen- and oxygen-bearing molecules from radiolysis of nitrous oxide ices - implications for Solar system and interstellar ices

    Science.gov (United States)

    de Barros, A. L. F.; da Silveira, E. F.; Fulvio, D.; Boduch, P.; Rothard, H.

    2017-03-01

    The radiolysis of pure N2O ice at 11 and 75 K by 90 MeV 136Xe23 + ion irradiation has been studied by Fourier-transformed infrared spectroscopy (FTIR). Six daughter molecular species have been observed: NO2, (NO)2, N2O3, N2O4, N2O5, and O3. The chemical evolution of the new molecules formed in the sample was followed by the measurement of the column densities of the precursor and products as a function of the beam fluence. This procedure allows the determination of their formation and dissociation cross-sections. Other processes monitored by FTIR were sublimation (non-existent at 11 K, but present at 75 K) and ice compaction by the ion beam. Comparison between results obtained for the 11 and 75 K ices shows that formation and destruction cross-sections are higher (for light products) or much higher (for heavy products) at 75 K. This enhancement of chemical activity at higher temperature should not be attributed to higher projectile ionization rate but rather to a higher mobility of the radiolysis products in an ice undergoing slow sublimation. Although N2O ice has not yet been observed in space, it is reasonable to expect its occurrence since N and O are very abundant and reactive. Furthermore, if this ice is actually absent, the knowledge of the chemical-physical processes induced by ion irradiation on N2O ice at low temperature is necessary to explain its depletion.

  6. Pulse-Width Jitter Measurement for Laser Diode Pulses

    Institute of Scientific and Technical Information of China (English)

    TANG Jun-Hua; WANG Yun-Cai

    2006-01-01

    @@ Theoretical analysis and experimental measurement of pulse-width jitter of diode laser pulses are presented. The expression of pulse power spectra with all amplitude jitter, timing jitter and pulse-width jitter is deduced.

  7. Degradation of naphthalene and fluorene by radiolysis using accelerated electrons; Degradacion de naftaleno y fluoreno por radiolisis empleando electrones acelerados

    Energy Technology Data Exchange (ETDEWEB)

    Flores de Jesus, I

    2003-07-01

    solution to the problems in this matter that faces our country. The experimentation made consisted of the irradiation of naphthalene and fluorene in liquid solution (acetone), preparing the solution to a well-known concentration, radiating of joint way to different doses, under conditions of operation of the accelerator as they are: emptiness, energy and constant current. An analytical method was established for the application of the analytical technique of gas chromatography/mass spectrometry (GC/MS), in order to determine the concentration compounds before and after its irradiation. The outcomes shows that a significant degradation was reached; 41.37 % for naphthalene and 31.29 % for the fluorene with a dose of 99.30 kGy in both, it was possible to appreciate that these do not keep one narrow relation as far as the degradation as increases the dose. Since it was demonstrated that a degradation exists and this is increased based on the dose, it is recommended to make studies applying greater doses of the amount used in this thesis, until finding the optimal point based on the dose, in addition to the radiolysis of the water. These results will be useful to propose that experiments will be made to obtain more efficient results for the solution of the contamination of organic compounds in residual waters. (Author)

  8. PulseSoar

    Energy Technology Data Exchange (ETDEWEB)

    Carter, P.; Peglow, S.

    1992-07-21

    This paper is an introduction to the PulseSoar concept. PulseSoar is a hypervelocity airplane that uses existing airport facilities and current technologies to fly at the very edge of space. It will be shown that PulseSoar can fly between any two points on the globe in less than two hours with fuel efficiency exceeding current state of the art commercial airliners. In addition, it will be shown that PulseSoar avoids environmental issues concerning the ozone layer and sonic booms because of its unique flight profile. All of this can be achieved with current technology. PulseSoar does not require the development of enabling technology. It is a concept which can be demonstrated today. The importance of this idea goes beyond the technical significance`s of PulseSoar in terms of feasibility and performance. PulseSoar could provide a crucial economic advantage to America`s largest export market: commercial aircraft. PulseSoar is a breakthrough concept for addressing the emerging markets of long range and high speed aircraft. Application of PulseSoar to commercial transport could provide the US Aerospace industry a substantial lead in offering high speed/long range aircraft to the world`s airlines. The rapid emergence of a US developed high speed aircraft could also be important to our competitiveness in the Pacific Rim and South American economies. A quick and inexpensive demonstration vehicle is proposed to bang the concept to reality within two years. This discussion will address all the major technical subjects encompassed by PulseSoar and identifies several near-term, and low risk, applications which may be further explored with the initial demonstration vehicle. What is PulseSoar? PulseSoar could enable high speed, high altitude and long range flight without many of the difficulties encountered by traditional hypersonic vehicles.

  9. In Situ Detection of Chlorine Dioxide (C1O2) in the Radiolysis of Perchlorates and Implications for the Stability of Organics on Mars

    Science.gov (United States)

    Góbi, Sándor; Bergantini, Alexandre; Kaiser, Ralf I.

    2016-12-01

    Magnesium perchlorate hexahydrate (Mg(ClO4)2 · 6H2O) samples were exposed to energetic electrons to investigate the products of the decomposition of perchlorates in the Martian soil and to infer their role in the degradation of organics on Mars. The samples were monitored online and in situ via infrared spectroscopy as well as electron impact (EI-QMS) and reflectron time-of-flight mass spectrometry coupled with single photon ionization (PI-ReTOF-MS). Our study reveals that besides chlorates ({{{ClO}}3}-) and molecular oxygen (O2), the chlorine dioxide radical (ClO2) was observed online and in situ for the first time as a radiolysis product of solid perchlorates. Chlorine dioxide, which is used on Earth as a strong oxidizing agent in water disinfection and bleaching, represents a proficient oxidizer—potentially more powerful than molecular oxygen—to explain the lack of abundant organics in the Martian soil.

  10. Structural characterisation of degradation products formed upon di-n-butyl phthalate radiolysis by high-performance liquid chromatography electro-spray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tintaru, A.; Charles, L. [Univ Aix Marseille 1, CNRS, Lab Chim Provence Spectrometries Appl Chim Struct, UMR 6264, F-13397 Marseille (France); Univ Aix Marseille 2, CNRS, Lab Chim Provence Spectrometries Appl Chim Struct, UMR 6264, F-13397 Marseille (France); Labed, V. [CEA Marcoule, DTCD SPDE L2ED, F-30207 Bagnols Sur Ceze (France)

    2010-07-01

    Complete text of publication follows: Structural characterisation of 15 degradation products, formed upon di-n-butyl phthalate (DBP) radiolysis, has been achieved using a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) coupling. The dissociation behaviour of protonated DBP was first established to be further used to characterise structural deviation in the degradation products. Based on accurate mass measurements, compounds shown by HPLC-MS analysis were all found to be DBP oxidation products, amongst which various sets of isomers could be distinguished. Collision-induced dissociation experiments performed on each electro-sprayed molecule first allowed unambiguous definition of the location of the additional oxygen atoms; that is, in the alkyl branch or on the aromatic ring. Although location of the oxygen atom in the alkyl branches could not always be precisely determined, relative abundances of some product ions allowed oxygenated functions to be identified

  11. A study of low-energy ion induced radiolysis of thiol-containing amino acid cysteine in the solid and aqueous solution states

    Energy Technology Data Exchange (ETDEWEB)

    Ke Zhigang [Key Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, 350 Shushanhu Road, P.O. Box 1126, Hefei 230031 (China); Huang Qing, E-mail: huangq@ipp.ac.c [Key Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, 350 Shushanhu Road, P.O. Box 1126, Hefei 230031 (China); Dang Bingrong [Institute of Modern Physics, Chinese Academy of Sciences, 509 Nanchang Road, Lanzhou 730000 (China); Lu Yilin [Key Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, 350 Shushanhu Road, P.O. Box 1126, Hefei 230031 (China); Department of Physics, Anhui University, Hefei 230031 (China); Yuan Hang; Zhang Shuqing; Yu Zengliang [Key Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, 350 Shushanhu Road, P.O. Box 1126, Hefei 230031 (China)

    2010-09-15

    The radiolysis of cysteine under plasma discharge and irradiation of low-energy ion beam was investigated. The damage of cysteine in aqueous solution under discharge was assessed via the acid ninhydrin reagent and the yield of cystine produced from the reaction was analyzed by FTIR. In addition, the generation of hydrogen sulfide was also identified. The destruction of solid cysteine under low-energy ion beam irradiation was estimated via monitoring IR bands of different functional groups (-SH, -NH{sub 3}, -COO{sup -}) of cysteine, and the production of cystine from ion-irradiated solid cysteine after dissolution in water was also verified. These results may help us to understand the inactivation of sulphydryl enzymes under direct and indirect interaction with the low-energy ion irradiation.

  12. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  13. Ultrashort Laser Pulse Phenomena

    CERN Document Server

    Diels, Jean-Claude

    2006-01-01

    Ultrashort Laser Pulse Phenomena, 2e serves as an introduction to the phenomena of ultra short laser pulses and describes how this technology can be used to examine problems in areas such as electromagnetism, optics, and quantum mechanics. Ultrashort Laser Pulse Phenomena combines theoretical backgrounds and experimental techniques and will serve as a manual on designing and constructing femtosecond (""faster than electronics"") systems or experiments from scratch. Beyond the simple optical system, the various sources of ultrashort pulses are presented, again with emphasis on the basic

  14. Structural changes caused by radiation-induced reduction and radiolysis: the effect of X-ray absorbed dose in a fungal multicopper oxidase

    Energy Technology Data Exchange (ETDEWEB)

    De la Mora, Eugenio [Universidad Nacional Autónoma de México, Avenida Universidad 2001, Cuernavaca, Morelos 62210 (Mexico); Lovett, Janet E. [University of Oxford, South Parks Road, Oxford OX1 3QR (United Kingdom); University of Oxford, South Parks Road, Oxford OX1 3RE (United Kingdom); EaStCHEM School of Chemistry, Joseph Black Building, The King’s Buildings, Edinburgh EH9 3JJ, Scotland (United Kingdom); Blanford, Christopher F. [University of Oxford, South Parks Road, Oxford OX1 3QR (United Kingdom); Manchester Interdisciplinary Biocentre, 131 Princess Street, Manchester M1 7DN (United Kingdom); Garman, Elspeth F. [University of Oxford, South Parks Road, Oxford OX1 3QU (United Kingdom); Valderrama, Brenda; Rudino-Pinera, Enrique, E-mail: rudino@ibt.unam.mx [Universidad Nacional Autónoma de México, Avenida Universidad 2001, Cuernavaca, Morelos 62210 (Mexico)

    2012-05-01

    Radiation-induced reduction, radiolysis of copper sites and the effect of pH value together with the concomitant geometrical distortions of the active centres were analysed in several fungal (C. gallica) laccase structures collected at cryotemperature. This study emphasizes the importance of careful interpretation when the crystallographic structure of a metalloprotein is described. X-ray radiation induces two main effects at metal centres contained in protein crystals: radiation-induced reduction and radiolysis and a resulting decrease in metal occupancy. In blue multicopper oxidases (BMCOs), the geometry of the active centres and the metal-to-ligand distances change depending on the oxidation states of the Cu atoms, suggesting that these alterations are catalytically relevant to the binding, activation and reduction of O{sub 2}. In this work, the X-ray-determined three-dimensional structure of laccase from the basidiomycete Coriolopsis gallica (Cg L), a high catalytic potential BMCO, is described. By combining spectroscopic techniques (UV–Vis, EPR and XAS) and X-ray crystallography, structural changes at and around the active copper centres were related to pH and absorbed X-ray dose (energy deposited per unit mass). Depletion of two of the four active Cu atoms as well as low occupancies of the remaining Cu atoms, together with different conformations of the metal centres, were observed at both acidic pH and high absorbed dose, correlating with more reduced states of the active coppers. These observations provide additional evidence to support the role of flexibility of copper sites during O{sub 2} reduction. This study supports previous observations indicating that interpretations regarding redox state and metal coordination need to take radiation effects explicitly into account.

  15. Pulsed Plasma Electron Sources

    Science.gov (United States)

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  16. PULSE AMPLITUDE DISTRIBUTION RECORDER

    Science.gov (United States)

    Cowper, G.

    1958-08-12

    A device is described for automatica1ly recording pulse annplitude distribution received from a counter. The novelty of the device consists of the over-all arrangement of conventional circuit elements to provide an easy to read permanent record of the pulse amplitude distribution during a certain time period. In the device a pulse analyzer separates the pulses according to annplitude into several channels. A scaler in each channel counts the pulses and operates a pen marker positioned over a drivable recorder sheet. Since the scalers in each channel have the sanne capacity, the control circuitry permits counting of the incoming pulses until one scaler reaches capacity, whereupon the input is removed and an internal oscillator supplies the necessary pulses to fill up the other scalers. Movement of the chart sheet is initiated wben the first scaler reaches capacity to thereby give a series of marks at spacings proportional to the time required to fill the remaining scalers, and accessory equipment marks calibration points on the recorder sheet to facilitate direct reading of the number of external pulses supplied to each scaler.

  17. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1990-01-01

    Florida State University is investigating the concept of pulsed electron beams for fly ash precipitation. This report describes the results and data on three of the subtasks of this project and preliminary work only on the remaining five subtasks. Described are the modification of precharger for pulsed and DC energization of anode; installation of the Q/A measurement system; and modification and installation of pulsed power supply to provide both pulsed and DC energization of the anode. The other tasks include: measurement of the removal efficiency for monodisperse simulated fly ash particles; measurement of particle charge; optimization of pulse energization schedule for maximum removal efficiency; practical assessment of results; and measurement of the removal efficiency for polydisperse test particles. 15 figs., 1 tab. (CK)

  18. Pulse Distortion in Saturated Fiber Optical Parametric Chirped Pulse Amplification

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Da Ros, Francesco; Rottwitt, Karsten

    2012-01-01

    Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation.......Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation....

  19. RF Pulsed Heating

    Energy Technology Data Exchange (ETDEWEB)

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  20. Efficient Pulsed Quadrupole

    CERN Document Server

    Petzenhauser, I.; Spiller, P.; Tenholt, C.

    2016-01-01

    In order to raise the focusing gradient in case of bunched beam lines, a pulsed quadrupole was designed. The transfer channels between synchrotrons as well as the final focusing for the target line are possible applications. The quadrupole is running in a pulsed mode, which means an immense saving of energy by avoiding standby operation. Still the high gradients demand high currents. Hence a circuit had to be developed which is able to recover a significant amount of the pulsing energy for following shots. The basic design of the electrical circuit of the quadrupole is introduced. Furthermore more energy efficient circuits are presented and the limits of adaptability are considered.

  1. Pulse joining cartridges

    Energy Technology Data Exchange (ETDEWEB)

    Golovashchenko, Sergey Fedorovich; Bonnen, John Joseph Francis

    2016-08-23

    A pulsed joining tool includes a tool body that defines a cavity that receives an inner tubular member and an outer tubular member and a pulse joining cartridge. The tubular members are nested together with the cartridge being disposed around the outer tubular member. The cartridge includes a conductor, such as a wire or foil, that extends around the outer tubular member and is insulated to separate a supply segment from a return segment. A source of stored electrical energy is discharged through the conductor to join the tubular members with an electromagnetic force pulse.

  2. DogPulse

    DEFF Research Database (Denmark)

    Skovgaard, Christoffer; Thomsen, Josephine Raun; Verdezoto, Nervo;

    2015-01-01

    This paper presents DogPulse, an ambient awareness system to support the coordination of dog walking among family members at home. DogPulse augments a dog collar and leash set to activate an ambient shape-changing lamp and visualize the last time the dog was taken for a walk. The lamp gradually...... changes its form and pulsates its lights in order to keep the family members aware of the dog walking activity. We report the iterative prototyping of DogPulse, its implementation and its preliminary evaluation. Based on our initial findings, we present the limitations and lessons learned as well...

  3. Detection of OH and O{sub 2}{sup -} radicals generated by water radiolysis of water; Detection des radicaux OH et O{sub 2}{sup -} issus de la radiolyse de l'eau par chimiluminescence resolue en temps

    Energy Technology Data Exchange (ETDEWEB)

    Wasselin-Trupin, V.; Baldacchino, G.; Hickel, B. [CEA/Saclay, Centre National de la Recherche Scientifique-CNRS, Gif sur Yvette CEDEX (France)

    2001-02-01

    A new method for the detection of low concentrations of hydroxyl and superoxide radicals, formed by water radiolysis, is described in this article. The method used is the time resolved chemiluminescence. It has been performed with an electron beam delivered by a Febetron 707 accelerator. This method allows to measure hydroxyl and superoxide radical concentrations in a large range of concentrations, between 10{sup -5} and 10{sup -8} M. (author)

  4. Impact of radiolysis and radiolytic corrosion on the release of {sup 13}C and {sup 37}Cl implanted into nuclear graphite: Consequences for the behaviour of {sup 14}C and {sup 36}Cl in gas cooled graphite moderated reactors

    Energy Technology Data Exchange (ETDEWEB)

    Moncoffre, N., E-mail: nathalie.moncoffre@ipnl.in2p3.fr [Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR5822, Institut de Physique Nucléaire de Lyon (IPNL) (France); Toulhoat, N. [Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR5822, Institut de Physique Nucléaire de Lyon (IPNL) (France); CEA/DEN, Centre de Saclay (France); Bérerd, N.; Pipon, Y. [Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR5822, Institut de Physique Nucléaire de Lyon (IPNL) (France); Université de Lyon, Université Lyon, IUT Lyon-1 département chimie (France); Silbermann, G. [Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR5822, Institut de Physique Nucléaire de Lyon (IPNL) (France); EDF – DPI - DIN – CIDEN, DIE - Division Environnement, Lyon (France); Blondel, A. [Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR5822, Institut de Physique Nucléaire de Lyon (IPNL) (France); Andra, Châtenay-Malabry (France); Galy, N. [Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR5822, Institut de Physique Nucléaire de Lyon (IPNL) (France); EDF – DPI - DIN – CIDEN, DIE - Division Environnement, Lyon (France); and others

    2016-04-15

    Graphite finds widespread use in many areas of nuclear technology based on its excellent moderator and reflector qualities as well as its strength and high temperature stability. Thus, it has been used as moderator or reflector in CO{sub 2} cooled nuclear reactors such as UNGG, MAGNOX, and AGR. However, neutron irradiation of graphite results in the production of {sup 14}C (dose determining radionuclide) and {sup 36}Cl (long lived radionuclide), these radionuclides being a key issue regarding the management of the irradiated waste. Whatever the management option (purification, storage, and geological disposal), a previous assessment of the radioactive inventory and the radionuclide's location and speciation has to be made. During reactor operation, the effects of radiolysis are likely to promote the radionuclide release especially at the gas/graphite interface. Radiolysis of the coolant is mainly initiated through γ irradiation as well as through Compton electrons in the graphite pores. Radiolysis can be simulated in laboratory using γ irradiation or ion irradiation. In this paper, {sup 13}C, {sup 37}Cl and {sup 14}N are implanted into virgin nuclear graphite in order to simulate respectively the presence of {sup 14}C, {sup 36}Cl and nitrogen, a {sup 14}C precursor. Different irradiation experiments were carried out using different irradiation devices on implanted graphite brought into contact with a gas simulating the coolant. The aim was to assess the effects of gas radiolysis and radiolytic corrosion induced by γ or He{sup 2+} irradiation at the gas/graphite interface in order to evaluate their role on the radionuclide release. Our results allow inferring that radiolytic corrosion has clearly promoted the release of {sup 14}C, {sup 36}Cl and {sup 14}N located at the graphite brick/gas interfaces and open pores.

  5. Radiolysis study of Sulfarlem, a sulfured antioxidant, in linoleic acid micellar system. Etude radiolytique d'un antioxydant soufre, le Sulfarlem, en milieu micellaire contenant de l'acide linoleique

    Energy Technology Data Exchange (ETDEWEB)

    Ruimy-Ifrah, P.; Jore, D.; Ferradini, C. (Paris-5 Univ., 75 (France)); Christen, M.O. (LTM France, 92 - Suresnes (France))

    1993-04-01

    Sulfarlem is a dithiol-thione derivative which exhibits antioxidant properties. The study of the possible radical mechanisms involved in this action have been studied by mean of steady state radiolysis in aerated linoleic acid micellar system. The experimental results indicate that the presence of Sulfarlem in the irradiated medium decreases the degradation of linoleic acid and the formation of conjugated dienes, sulfarlem being consumed proportionally to the absorbed dose.

  6. Pulsed radiation studies of carotenoid radicals and excited states

    Energy Technology Data Exchange (ETDEWEB)

    Burke, M

    2001-04-01

    The one-electron reduction potentials of the radical cations of five dietary carotenoids, in aqueous micellar environments, have been obtained from a pulse radiolysis study of electron transfer between the carotenoids and tryptophan radical cations as a function of pH, and lie in the range 980 to 1060 mV. The decays of the carotenoid radical cations suggest a distribution of exponential lifetimes. The radicals persist for up to about one second, depending on the medium and may re-orientate within a biological environment to react with other biomolecules, such as tyrosine, cysteine or ascorbic acid, which was indeed confirmed. Spectral information of carotenoid pigmented liposomes has been collected, subsequently pulse radiolysis was used to generate the radical cations of {beta}-carotene, zeaxanthin and lutein, in unilamellar vesicles of dipalmitoyl phosphatidyl choline. The rate constants for the 'repair' of these carotenoid radical cations by water-soluble vitamin C were found to be similar ({approx}1 x 10{sup 7} M{sup -1}s{sup -1}) for {beta}-carotene and zeaxanthin and somewhat lower ({approx}0.5 x 10{sup 7} M{sup -1}s{sup -1}) for lutein. The results are discussed in terms of the microenvironment of the carotenoids and suggest that for {beta}-carotene, a hydrocarbon carotenoid, the radical cation is able to interact with a water-soluble species even though the parent hydrocarbon carotenoid is probably entirely in the non-polar region of the liposome. Studies investigating the ability of ingested lycopene to protect human lymphoid cells against singlet oxygen and nitrogen dioxide radical mediated cell damage have shown that a high lycopene diet is beneficial in protecting human cells against reactive oxygen species. Triplet states of carotenoids were produced in benzene solvent and their triplet lifetimes were found to depend on the concentration of the parent molecule. The rate constants obtained for ground state quenching correlate with the number

  7. Pulse measurement apparatus and method

    Science.gov (United States)

    Marciante, John R.; Donaldson, William R.; Roides, Richard G.

    2011-10-25

    An embodiment of the invention is directed to a pulse measuring system that measures a characteristic of an input pulse under test, particularly the pulse shape of a single-shot, nano-second duration, high shape-contrast optical or electrical pulse. An exemplary system includes a multi-stage, passive pulse replicator, wherein each successive stage introduces a fixed time delay to the input pulse under test, a repetitively-gated electronic sampling apparatus that acquires the pulse train including an entire waveform of each replica pulse, a processor that temporally aligns the replicated pulses, and an averager that temporally averages the replicated pulses to generate the pulse shape of the pulse under test. An embodiment of the invention is directed to a method for measuring an optical or an electrical pulse shape. The method includes the steps of passively replicating the pulse under test with a known time delay, temporally stacking the pulses, and temporally averaging the stacked pulses. An embodiment of the invention is directed to a method for increasing the dynamic range of a pulse measurement by a repetitively-gated electronic sampling device having a rated dynamic range capability, beyond the rated dynamic range of the sampling device; e.g., enhancing the dynamic range of an oscilloscope. The embodied technique can improve the SNR from about 300:1 to 1000:1. A dynamic range enhancement of four to seven bits may be achieved.

  8. Pulse subtraction Doppler

    Science.gov (United States)

    Mahue, Veronique; Mari, Jean Martial; Eckersley, Robert J.; Caro, Colin G.; Tang, Meng-Xing

    2010-01-01

    Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation.

  9. Pulsed spallation Neutron Sources

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, J.M. [Argonne National Lab., IL (United States)

    1994-12-31

    This paper reviews the early history of pulsed spallation neutron source development at Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provides a few examples of applications in fundamental condensed matter physics, materials science and technology.

  10. Four pulse recoupling

    Science.gov (United States)

    Khaneja, Navin; Kumar, Ashutosh

    2016-11-01

    The paper describes a family of novel recoupling pulse sequences in magic angle spinning (MAS) solid state NMR, called four pulse recoupling. These pulse sequences can be employed for both homonuclear and heteronuclear recoupling experiments and are robust to dispersion in chemical shifts and rf-inhomogeneity. The homonuclear pulse sequence consists of a building block (π/2) 0 °(3π/2) ϕ°(π/2) 180 ° + ϕ°(3π/2) 180 ° where ϕ = π/n (ϕ° = 180°/n) , and n is number of blocks in a two rotor period. The heteronuclear recoupling pulse sequence consists of a building block (π/2) 0 °(3π/2) ϕ1 °(π/2) 180 ° +ϕ1 °(3π/2) 180 ° and (π/2) 0 °(3π/2) ϕ2 °(π/2) 180 ° +ϕ2 °(3π/2) 180 ° on channel I and S, where ϕ1 = 3π/2n, ϕ2 = π2/n and n is number of blocks in a two rotor period. The recoupling pulse sequences mix the y magnetization. We show that four pulse recoupling is more broadband compared to three pulse recoupling [1]. Experimental quantification of this method is shown for 13Cα-13CO, homonuclear recoupling in a sample of Glycine and 15N-13Cα, heteronuclear recoupling in Alanine. Application of this method is demonstrated on a sample of tripeptide N-formyl-[U-13C,15N]-Met-Leu-Phe-OH (MLF).

  11. HYDROGEN GENERATION FROM SLUDGE SAMPLE BOTTLES CAUSED BY RADIOLYSIS AND CHEMISTRY WITH CONCETNRATION DETERMINATION IN A STANDARD WASTE BOX (SWB) OR DRUM FOR TRANSPORT

    Energy Technology Data Exchange (ETDEWEB)

    RILEY DL; BRIDGES AE; EDWARDS WS

    2010-03-30

    A volume of 600 mL of sludge, in 4.1 L sample bottles (Appendix 7.6), will be placed in either a Super Pig (Ref. 1) or Piglet (Ref. 2, 3) based on shielding requirements (Ref. 4). Two Super Pigs will be placed in a Standard Waste Box (SWB, Ref. 5), as their weight exceeds the capacity of a drum; two Piglets will be placed in a 55-gallon drum (shown in Appendix 7.2). The generation of hydrogen gas through oxidation/corrosion of uranium metal by its reaction with water will be determined and combined with the hydrogen produced by radiolysis. The hydrogen concentration in the 55-gallon drum and SWB will be calculated to show that the lower flammability limit of 5% hydrogen is not reached. The inner layers (i.e., sample bottle, bag and shielded pig) in the SWB and drum will be evaluated to assure no pressurization occurs as the hydrogen vents from the inner containers (e.g., shielded pigs, etc.). The reaction of uranium metal with anoxic liquid water is highly exothermic; the heat of reaction will be combined with the source term decay heat, calculated from Radcalc, to show that the drum and SWB package heat load limits are satisfied. This analysis does five things: (1) Estimates the H{sub 2} generation from the reaction of uranium metal with water; (2) Estimates the H{sub 2} generation from radiolysis (using Radcalc 4.1); (3) Combines both H{sub 2} generation amounts, from Items 1 and 2, and determines the percent concentration of H{sub 2} in the interior of an SWB with two Super Pigs, and the interior of a 55-gallon drum with two Piglets; (4) From the combined gas generation rate, shows that the pressure at internal layers is minimal; and (5) Calculates the maximum thermal load of the package, both from radioactive decay of the source and daughter products as calculated/reported by Radcalc 4.1, and from the exothermic reaction of uranium metal with water.

  12. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  13. Production of a fluorescence probe in ion-beam radiolysis of aqueous coumarin-3-carboxylic acid solution-1: Beam quality and concentration dependences

    Science.gov (United States)

    Maeyama, Takuya; Yamashita, Shinichi; Baldacchino, Gérard; Taguchi, Mitsumasa; Kimura, Atsushi; Murakami, Takeshi; Katsumura, Yosuke

    2011-04-01

    Aqueous coumarin-3-carboxylic acid (3-CCA) solutions were irradiated with seven different ion beams covering LET range from 0.5 to above 2000 eV/nm. G-values of 7OH-CCA, one of hydroxylated products in radiolysis of the solutions, have been determined by fluorescence-HPLC technique in 3-CCA concentration range from 0.1 to 26 mM. The formation yield of 7OH-CCA increased with increase in concentration of 3-CCA while it decreased with increase in LET value of ion beam. Compared with our previous reports on G(•OH) at a scavenging capacity of 107 s-1 with absorption spectroscopy, it was found that G(7OH-CCA) is about (4.7±0.6)% of G(•OH), which is consistent for all of the ion beams used in the present study. However, 7OH-CCA yields in high 3-CCA concentration region, especially by using extremely high LET ions, were much higher than expected values based on the above conversion factor and G(•OH) value predicted in theoretical work.

  14. Geometrical α- and β-dose distributions and production rates of radiolysis products in water in contact with spent nuclear fuel

    Science.gov (United States)

    Nielsen, Fredrik; Jonsson, Mats

    2006-12-01

    A mathematical model for the dose distribution and production rates of radiolysis products in water surrounding spent nuclear fuel has been developed, based on the geometrical and energetic properties of radiation. The nuclear fuel particle is divided into layers, from which the radiation emits. The water is likewise divided into layers, where the doses are distributed. The doses are stored in vectors which are added to determine the total dose rate. A complete inventory with over 200 radionuclides has been used as input data for the model. The purpose of the model is to describe the geometrical dose distribution as a function of fuel age and burn-up, to be used as input data for kinetic modeling of the fuel dissolution. The results show that the β-dose contribution close to the spent fuel surface is negligible. Also, the variation in the relative α/β dose contribution between different ages and burn-ups is insignificant. The α- and β-dose rates vary between different burn-ups of the same age; the younger the fuel is, the larger is the difference. Exponential functions have been fitted to the relations between fuel age and average dose rate, giving useful expressions for determining average dose rates for fuel ages other than those covered in this work.

  15. Production of a fluorescence probe in ion-beam radiolysis of aqueous coumarin-3-carboxylic acid solution-2: Effects of nuclear fragmentation and its simulation with PHITS

    Energy Technology Data Exchange (ETDEWEB)

    Maeyama, Takuya [Department of Nuclear Engineering and Management, School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Yamashita, Shinichi; Taguchi, Mitsumasa [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Baldacchino, Gerard [CEA Saclay, IRAMIS, UMR 3299 CEA-CNRS SIS2M, Laboratoire de Radiolyse, F-91191 Gif sur Yvette Cedex (France); Sihver, Lembit [Department of Physics, University of Houston, Houston, TX 77204-5005 (United States); Department of Nuclear Engineering, Texas A and M University, TX 77843-3133 (United States); Department of Roanoke College, Salem, VA 24153 (United States); Department of Nuclear Engineering, Applied Physics, Chalmers University of Technology, SE-41296 Gothenburg (Sweden); Murakami, Takeshi [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Katsumura, Yosuke, E-mail: katsu@n.t.u-tokyo.ac.jp [Department of Nuclear Engineering and Management, School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Nuclear Professional School, School of Engineering, University of Tokyo, 2-22 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki 319-1188 (Japan)

    2011-12-15

    The G(OH) values in aqueous coumarin-3-carboxylic-acid (3-CCA) solutions irradiated with {sup 12}C{sup 6+} beams having the energies of 135, 290 and 400 MeV/u were measured by a fluorescent method around the Bragg peak, with 0.6 mm intervals, and quartz cells of 1 cm optical lengths, at the Heavy Ion Medical Accelerator in Chiba, National Institute of Radiological Sciences (NIRS). For each ion, the G(OH) has been calculated as a function of dose average LET and position. The calculated results have been compared to measurements, and the results, reproducibility and reliability of the calculations are discussed in the paper. - Highlights: > Therapeutic ion beam has energy of several hundred MeV/u because it is necessary for a few tens cm range. > With such high energy, nuclear fragmentations of carbon ions occur resulting in production of lighter ions. > In this study, OH yield in water radiolysis near the Bragg peak of therapeutic ion beams was measured. > Measured yields are discussed considering nuclear fragmentation by PHITS code.

  16. Electron paramagnetic resonance study of radicals formed by radiolysis at 77 K of nitroalkanes and of their solutions in organic glasses. Chromatography analysis of radiolysis products of nitromethane in ethanol solution in a vitreous medium; Etude par resonance paramagnetique electronique des radicaux formes par radiolyse a 77 K des nitroalcanes et de leurs solutions dans les verres organiques analyse par chromatographie des produits de la radiolyse du nitromethane en solution dans l'ethanol en milieux vitreux

    Energy Technology Data Exchange (ETDEWEB)

    Rosilio, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-05-01

    With a view to explaining the formation of the final products resulting from the photolysis and the radiolysis of nitro-alkanes, we have attempted to identify the paramagnetic species formed as intermediates during the radiolysis. Our work has covered the structure and the reactivity of the radicals formed by 7 irradiation of the nitrogen containing derivatives at 77 K, and on the mechanism of formation and of disappearance of these radicals in the various matrices used. The radicals resulting from the removal of a hydrogen atom in the {alpha} position of the NO{sub 2} group, and the radicals resulting from addition reactions on the nitrogen group characterized by an unpaired electron on the nitrogen have been identified, either during the radiolysis of pure nitroalkanes, or during the radiolysis of nitro-alkanes in solution in organic glasses at 77 K. A study has been made of the conformation and the movements of radicals in the matrices, and the mechanism of formation of the observed radicals produced generally by the capture by the nitro-alkanes of primary radiolysis species. The nitro-alkanes in ethanol solution can behave as traps both for electrons and for free radicals. The study of the radiolysis of nitro-alkanes in solution in a polar ethanol glass has been completed with chemical analyses on the final radiolysis products; it has been possible to deduce the capture efficiency of trapped electrons and of free radicals by nitro-alkanes in ethanol. For this we have determined the radio-chemical yields of hydrogen, acetaldehyde and glycol as a function of the capture agent concentration, for the nitro-methane-ethanol system. A mechanism for the disappearance of the observed radicals is proposed. (author) [French] Dans le but d'expliquer la formation des produits finals formes au cours de la photolyse et la radiolyse des nitroalcanes, nous nous sommes proposes d'identifier les especes paramagnetiques se formant intermediairement au cours de la

  17. Discharge pulse phenomenology

    Science.gov (United States)

    Frederickson, A. R.

    1985-01-01

    A model was developed which places radiation induced discharge pulse results into a unified conceptual framework. Only two phenomena are required to interpret all space and laboratory results: (1) radiation produces large electrostatic fields inside insulators via the trapping of a net space charge density; and (2) the electrostatic fields initiate discharge streamer plasmas similar to those investigated in high voltage electrical insulation materials; these streamer plasmas generate the pulsing phenomena. The apparent variability and diversity of results seen is an inherent feature of the plasma streamer mechanism acting in the electric fields which is created by irradiation of the dielectrics. The implications of the model are extensive and lead to constraints over what can be done about spacecraft pulsing.

  18. Pulsed ELDOR detected NMR

    Science.gov (United States)

    Schosseler, P.; Wacker, Th.; Schweiger, A.

    1994-07-01

    A pulsed EPR method for the determination of small hyperfine interactions in disordered systems is described. A selective preparation pulse of frequency ω mw(1) excites allowed and forbidden transitions, thereby burning spectral holes into the EPR line. The positions of the holes caused by the excitation of forbidden transitions correspond to the nuclear transition frequencies of the spin system. A selective detection pulse of frequency ω mw(2) creates an FID with integrated intensity proportional to the magnetization at frequency ω mw(2). The entire hole pattern is obtained by recording the integrated intensity of the FID while varying the frequency difference Δω mw=ω mw(1)-ω mw(2) step by step.

  19. Herophilus on pulse

    Directory of Open Access Journals (Sweden)

    Afonasin, Eugene

    2015-01-01

    Full Text Available The first detailed study of the pulse (sphygmology is associated in antiquity with Herophilus (the end of the 4th century BCE, an Alexandrian physician, renowned for his anatomical discoveries. The scholars also attribute to him a discovery of a portable and adjustable water-clock, used for measuring ‘natural’ and ‘unnatural’ pulse and, accordingly, temperature of the patient. In the article we translate the principal ancient evidences and comment upon them. We study both the practical aspects of ancient sphygmology and the theoretical speculations associated with it. Ancient theory of proportion and musical harmony allowed to build a classification of the pulses, but the medical experience did not fit well in the Procrustean bed of this rather simple theory.

  20. Pulsed Artificial Electrojet Generation

    Science.gov (United States)

    Papadopoulos, K.

    2008-12-01

    Traditional techniques for generating low frequency signals in the ULF/ELF range (.1-100 Hz) and rely on ground based Horizontal Electric Dipole (HED) antennas. It is, furthermore, well known that a Vertical Electric Dipole (VED) is by more than 50 dB more efficient than a HED with the same dipole current moment. However, the prohibitively long length of VED antennas in the ELF/ULF range coupled with voltage limitations due to corona discharge in the atmosphere make them totally impracticable. In this paper we discuss a novel concept, inspired by the physics of the equatorial electrojet, that allows for the conversion of a ground based HED to a VED in the E-region of the equatorial ionosphere with current moment comparable to the driving HED. The paper focuses in locations near the dip-equator, where the earth's magnetic is in predominantly in the horizontal direction. The horizontal electric field associated with a pulsed HED drives a large Hall current in the ionospheric E-region, resulting in a vertical current. It is shown that the pulsed vertical current in the altitude range 80-130 km, driven by a horizontal electric field of, approximately, .1 mV/m at 100 km altitude, is of the order of kA. This results in a pulsed VED larger than 106 A-m. Such a pulsed VED will drive ELF/ULF pulses with amplitude in excess of .1 nT at a lateral range larger than few hundred kilometers. This is by three orders of magnitude larger than the one expected by a HED with comparable current moment. The paper will conclude with the description of a sneak-through technique that allows for creating pulsed electric fields in the ionosphere much larger than expected from steady state oscillatory HED antennas.

  1. Two pulse recoupling

    Science.gov (United States)

    Khaneja, Navin; Kumar, Ashutosh

    2017-08-01

    The paper describes a family of novel recoupling pulse sequences in magic angle spinning (MAS) solid state NMR, called two pulse recoupling. These pulse sequences can be employed for both homonuclear and heteronuclear recoupling experiments and are robust to dispersion in chemical shifts and rf-inhomogeneity. The homonuclear pulse sequence consists of a building block (π)ϕ(π) - ϕ where ϕ =π/4n, and n is number of blocks in a rotor period. The recoupling block is made robust to rf-inhomogeneity by extending it to (π)ϕ(π) - ϕ(π) π + ϕ(π) π - ϕ . The heteronuclear recoupling pulse sequence consists of a building block (π)ϕ1(π)-ϕ1 and (π)ϕ2(π)-ϕ2 on channel I and S, where ϕ1 = 3π/8n, ϕ2 = π/8n and n is number of blocks in a rotor period. The recoupling block is made robust to rf-inhomogeneity by extending it to (π)ϕ1(π)-ϕ1(π) π +ϕ1(π) π -ϕ1 and (π)ϕ2(π)-ϕ2(π) π +ϕ2(π) π -ϕ2 on two channels respectively. The recoupling pulse sequences mix the z magnetization. Experimental quantification of this method is shown for 13Cα-13CO homonuclear recoupling in a sample of Glycine and 15N-13Cα heteronuclear recoupling in Alanine. Application of this method is demonstrated on a sample of tripeptide N-formyl-[U-13C,15N]-Met-Leu-Phe-OH (MLF). Compared to R-sequences (Levitt, 2002), these sequences are more robust to rf-inhomogeneity and give better sensitivity, as shown in Fig. 3.

  2. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  3. Pulsed Electron Holography

    CERN Document Server

    Germann, Matthias; Escher, Conrad; Fink, Hans-Werner

    2013-01-01

    A technique of pulsed low-energy electron holography is introduced that allows for recording highly resolved holograms within reduced exposure times. Therefore, stacks of holograms are accumulated in a pulsed mode with individual acquisition times as short as 50 {\\mu}s. Subsequently, these holograms are aligned and finally superimposed. The resulting holographic record reveals previously latent high-order interference fringes and thereby pushing interference resolution into the sub-nanometer regime. In view of the non-damaging character of low-energy electrons, the method is of particular interest for structural analysis of fragile biomolecules.

  4. SNMR pulse sequence phase cycling

    Science.gov (United States)

    Walsh, David O; Grunewald, Elliot D

    2013-11-12

    Technologies applicable to SNMR pulse sequence phase cycling are disclosed, including SNMR acquisition apparatus and methods, SNMR processing apparatus and methods, and combinations thereof. SNMR acquisition may include transmitting two or more SNMR pulse sequences and applying a phase shift to a pulse in at least one of the pulse sequences, according to any of a variety cycling techniques. SNMR processing may include combining SNMR from a plurality of pulse sequences comprising pulses of different phases, so that desired signals are preserved and indesired signals are canceled.

  5. Pulse distortion in single-mode fibers. 3: Chirped pulses.

    Science.gov (United States)

    Marcuse, D

    1981-10-15

    The theory of pulse distortion in single-mode fibers is extended to include laser sources that suffer a linear wavelength sweep (chirp) during the duration of the pulse. The transmitted pulse is expressed as a Fourier integral whose spectral function is given by an analytical expression in closed form. The rms width of the transmitted pulse is also expressed in closed form. Numerical examples illustrate the influence of the chirp on the shape and rms width of the pulse. A somewhat paradoxical situation exists. A given input pulse can be made arbitrarily short by a sufficiently large amount of chirping, and, after a given fiber length, this chirped pulse returns to its original width. But at this particular distance an unchirped pulse would be only [equiation] times longer. Thus chirping can improve the rate of data transmission by only 40%.

  6. Solid-state pulse forming module with adjustable pulse duration

    Science.gov (United States)

    Wang, Langning; Liu, Jinliang; Qiu, Yongfeng; Chu, Xu; Zhang, Qingmeng

    2017-03-01

    A new solid-state pulse forming module is described in this paper. The pulse forming module is fabricated on a glass ceramic substrate, with the dimension of 250 mm × 95 mm × 4 mm. By changing the copper strips used in the pulse forming modules, the pulse duration of the obtained pulsed can range from 80 ns to 140 ns. Both the simulation and tests show that the pulse forming module has a good pulse forming ability. Under a high voltage in microsecond's time, the new pulse forming modules can hold off a voltage up to 25 kV higher than that of the previous study. In addition, future optimization for the field enhancement near the thin electrode edge has been proposed and simulated.

  7. Ultrafast optomechanical pulse picking

    Science.gov (United States)

    Lilienfein, Nikolai; Holzberger, Simon; Pupeza, Ioachim

    2017-01-01

    State-of-the-art optical switches for coupling pulses into and/or out of resonators are based on either the electro-optic or the acousto-optic effect in transmissive elements. In high-power applications, the damage threshold and other nonlinear and thermal effects in these elements impede further improvements in pulse energy, duration, and average power. We propose a new optomechanical switching concept which is based solely on reflective elements and is suitable for switching times down to the ten-nanosecond range. To this end, an isolated section of a beam path is moved in a system comprising mirrors rotating at a high angular velocity and stationary imaging mirrors, without affecting the propagation of the beam thereafter. We discuss three variants of the concept and exemplify practical parameters for its application in regenerative amplifiers and stack-and-dump enhancement cavities. We find that optomechanical pulse picking has the potential to achieve switching rates of up to a few tens of kilohertz while supporting pulse energies of up to several joules.

  8. Pulsed electric fields

    Science.gov (United States)

    The concept of pulsed electric fields (PEF) was first proposed in 1967 to change the behavior or microorganisms. The electric field phenomenon was identified as membrane rupture theory in the 1980s. Increasing the membrane permeability led to the application of PEF assisted extraction of cellular co...

  9. Pulsed inductive HF laser

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  10. Downhole pulse tube refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.; Gardner, D. [Los Alamos National Lab., NM (United States). Condensed Matter and Thermal Physics Group

    1997-12-01

    This report summarizes a preliminary design study to explore the plausibility of using pulse tube refrigeration to cool instruments in a hot down-hole environment. The original motivation was to maintain Dave Reagor`s high-temperature superconducting electronics at 75 K, but the study has evolved to include three target design criteria: cooling at 30 C in a 300 C environment, cooling at 75 K in a 50 C environment, cooling at both 75 K and 30 C in a 250 C environment. These specific temperatures were chosen arbitrarily, as representative of what is possible. The primary goals are low cost, reliability, and small package diameter. Pulse-tube refrigeration is a rapidly growing sub-field of cryogenic refrigeration. The pulse tube refrigerator has recently become the simplest, cheapest, most rugged and reliable low-power cryocooler. The authors expect this technology will be applicable downhole because of the ratio of hot to cold temperatures (in absolute units, such as Kelvin) of interest in deep drilling is comparable to the ratios routinely achieved with cryogenic pulse-tube refrigerators.

  11. Study of the effect of water radiolysis on zirconolite dissolution; Etude de l'effet de la radiolyse de l'eau sur la livixation de la zirconolite

    Energy Technology Data Exchange (ETDEWEB)

    Tribet, M

    2007-09-15

    Zirconolite is one of the matrices foreseen for the confinement of minor actinides in case of deep geological disposal. Indeed, zirconolite (general formula: CaZr{sub x}Ti{sub 3-x}O{sub 7} (0.8 {<=} x {<=} 1.37)) is able to incorporate rare earth elements and actinides by substitution in calcium and zirconium sites and, moreover, its chemical durability into water is well known. However, in case of deep geological disposal, after a long period, water can reach the confinement matrix and can be radiolysed at the moment of the radionuclide alpha decays. In this work we have thus studied the effects of water radiolysis induced by charged particles (alphas or protons) on the dissolution of a synthetic sintered zirconolite. The formula of this zirconolite is Ca{sub 0,8}Nd{sub 0,2}ZrTi{sub 1,8}Al{sub 0,2}O{sub 7} where Nd simulates the presence of trivalent and tetravalent actinides. We performed the irradiations with external ion beams in two distinct geometries where the fluences ranged from 10{sup 15} to 10{sup 16} ions.cm{sup -2}. In the first geometry the beam stops into water before the surface/water interface. In the second one the beam gets through the sample before stopping at the surface/water interface. The use of these different configurations allows to study the respective influence of parameters such as sample irradiation, Linear Energy Transfer at the surface/water interface or total deposited energy. The irradiations were performed on both crystalline and amorphous zirconolites in pure water or with complexing species such as F{sup -}. The sample dissolution has been monitored through the release of cations. The radiolytic production of H{sub 2}O{sub 2} has also been measured. Our results show that the water radiolysis has an effect on the preferential release of Zr, Ti and Nd: for these elements, releases are one or two order of magnitude higher than releases out of radiolysis. Such preferential releases occur whatever the temperature (20 or 50 C), the

  12. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J.; Nelson, Scott D.; Poole, Brian R.

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  13. Bacterial inactivation using pulsed light

    OpenAIRE

    Elmnasser, Noura; Ritz, Magali; Leroi, Francoise; Orange, Nicole; Bakhrouf, Amina; Federighi, Michel

    2007-01-01

    Pulsed light is a new method intended for the decontamination of food surfaces using short, high frequency pulses of an intense broad spectrum. The effects of broad spectrum pulsed light on the survival of Listeria monocytogenes Scott A, Listeria monocytogenes CNL, Pseudomonas fluorescens MF37 and Photobacterium phosphoreum SF680 populations on agar and in a liquid medium were investigated during this study. The sterilisation system generated 1.5 J cm(-2) per pulse with eight lamps for 300 mu...

  14. State of knowledge on the water radiolysis in cemented wasteforms and its approach by simulation; Etat des connaissances sur la radiolyse de l'eau dans les colis de dechets cimentes et son approche par simulation

    Energy Technology Data Exchange (ETDEWEB)

    Bouniol, P

    2004-07-01

    The decomposition of water under radiation within the cementitious matrix is at the origin of a potential source of harmful effects in the wasteform and their environment (pressurization and emanation of di-hydrogen) which can have an impact on the safety. In the aim of a better evaluation of the 'H{sub 2}' risk induced by such a complex and heterogeneous system, this document is an analysis of the elements necessary for a global understanding of the radiolysis in the cemented wasteform to be achieved: - summary of the basic knowledge on water radiolysis with transposition to the cementitious medium, - critical review of the various phenomenologies at work in a wasteform (radioactive source-term, gas transport, mineral equilibria); description of their mutual couplings and of their feedback on radiolytic chemistry; identification of the determining parameters, - presentation of a selection of experimental facts putting in light some theoretical points, - presentation of an outline of operational model deriving from the global vision; presentation of an adapted tool for simulation (CHEMSIMUL) and study of the influence of the principal parameters, starting from a reference case. The main result of this work is that it is shown, in the case of a {beta}{gamma} source term, that the control of the pore fluid composition by calcium octo-hydrate peroxide constitutes an efficient regulating mechanism for the radiolysis and H{sub 2} production. Not likely possible in the case of an {alpha} source term, this suggests a separate management of the wasteform according to their radiological contents. The gaps and limits of the model which are also evoked are promising of a lot of research prospects, primarily of a fundamental nature (impact of the porous medium). (author)

  15. Development of hydrogen oxidizing bacteria using hydrogen from radiolysis or metal corrosion; Developpement de populations microbiennes oxydant l'hydrogene produit par radiolyse ou par corrosion des metaux

    Energy Technology Data Exchange (ETDEWEB)

    Libert, M.F.; Sellier, R.; Marty, V.; Camaro, S. [CEA Cadarache, Dept. d' Entreposage et de Stockage des Dechets (DCC/DESD/SEP), 13 - Saint-Paul-lez-Durance (France)

    2000-07-01

    The effect of many parameters need to be studied to characterize the long term behavior of nuclear waste in a deep repository. These parameters concern the chemical effects, radiolytic effects, mechanical properties, water composition, and microbiological activity. To evaluate microbial activity in such an environment, work was focused on an inventory of key nutrients (C, H, 0, N, P, S) and energy sources required for bacterial growth. The production of hydrogen in the nuclear waste environment leads to the growth of hydrogen oxidizing bacteria, which modify the gas production balance. A deep repository containing bituminized waste drums implies several sources of hydrogen: - water radiolysis; -corrosion of metal containers; - radiolysis of the embedding matrix (bitumen). Two deep geological disposal conditions leading to H{sub 2} production in a bituminized nuclear waste environment were simulated in the present study: - H{sub 2} production by iron corrosion under anaerobic conditions was simulated by adding 10% of H{sub 2} in the atmosphere; - H{sub 2} production by radiolysis of bitumen matrix was approached by subjecting this material to external gamma irradiation with a dose rate near real conditions (6 Gy/h). The presence of dissolved H{sub 2} in water allows the growth of hydrogen oxidizing bacteria leading to: - CO{sub 2} and N{sub 2} production; - H{sub 2} consumption; - lower NO{sub 3}{sup -} concentration caused by reduction to nitrogen. In the first case, hydrogen consumption is limited by the NO{sub 3}{sup -} release rate from the bitumen matrix. In the second case, however, under gamma radiation at a low dose rate, hydrogen production is weak, and the hydrogen is completely consumed by microorganisms. Knowledge about these hydrogen oxidizing bacteria is just beginning to emerge. Heterotrophic denitrifying bacteria adapt well to hydrogen metabolism (autotrophic metabolism) by oxidizing H{sub 2} instead of hydrocarbons. (authors)

  16. A THERMAL PULSE SHAPER MECHANISM.

    Science.gov (United States)

    A shaped pulse of intense thermal radiation, corresponding to the pulses from nuclear weapons, is obtained by the output of a QM carbon arc. A flywheel driven by a DC motor actuated a venetian blind shutter placed between a mirror and the target to control the flux. The combination produced reasonably good simulation and reproduction of the generalized field pulse.

  17. Noisy homoclinic pulse dynamics

    Science.gov (United States)

    Eaves, T. S.; Balmforth, Neil J.

    2016-04-01

    The effect of stochastic perturbations on nearly homoclinic pulse trains is considered for three model systems: a Duffing oscillator, the Lorenz-like Shimizu-Morioka model, and a co-dimension-three normal form. Using the Duffing model as an example, it is demonstrated that the main effect of noise does not originate from the neighbourhood of the fixed point, as is commonly assumed, but due to the perturbation of the trajectory outside that region. Singular perturbation theory is used to quantify this noise effect and is applied to construct maps of pulse spacing for the Shimizu-Morioka and normal form models. The dynamics of these stochastic maps is then explored to examine how noise influences the sequence of bifurcations that take place adjacent to homoclinic connections in Lorenz-like and Shilnikov-type flows.

  18. Computationally intelligent pulsed photoacoustics

    Science.gov (United States)

    Lukić, Mladena; Ćojbašić, Žarko; Rabasović, Mihailo D.; Markushev, Dragan D.

    2014-12-01

    In this paper, the application of computational intelligence in pulsed photoacoustics is discussed. Feedforward multilayer perception networks are applied for real-time simultaneous determination of the laser beam spatial profile and vibrational-to-translational relaxation time of the polyatomic molecules in gases. Networks are trained and tested with theoretical data adjusted for a given experimental set-up. Genetic optimization has been used for calculation of the same parameters, fitting the photoacoustic signals with a different number of generations. Observed benefits from the application of computational intelligence in pulsed photoacoustics and advantages over previously developed methods are discussed, such as real-time operation, high precision and the possibility of finding solutions in a wide range of parameters, similar to in experimental conditions. In addition, the applicability for practical uses, such as the real-time in situ measurements of atmospheric pollutants, along with possible further developments of obtained results, is argued.

  19. Micro pulse laser radar

    Science.gov (United States)

    Spinhirne, James D. (Inventor)

    1993-01-01

    An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering is disclosed. The transmitter of the micro pulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited to optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that micropulse lider systems are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

  20. Magnetic Pulse Welding Technology

    Directory of Open Access Journals (Sweden)

    Ahmad K. Jassim

    2011-12-01

    Full Text Available In this paper, the benefits of using Magnetic Pulse machine which is belong to Non-conventional machine instead of conventional machine. Magnetic Pulse Technology is used for joining dissimilar metals, and for forming and cutting metals. It is a non contact technique. Magnetic field is used to generate impact magnetic pressure for welding and forming the work piece by converted the electrical energy to mechanical energy. It is enable us to design previously not possible by welding dissimilar materials and allowing to welds light and stronger materials together. It can be used to weld metallic with non metallic materials to created mechanical lock on ceramics, polymers, rubbers and composites. It is green process; there is no heat, no radiation, no gas, no smoke and sparks, therefore the emissions are negligible.

  1. Measurement of pulse lengthening with pulse energy increase in picosecond Nd:YAG laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Cutolo, A.; Zeni, L.; Berardi, V.; Bruzzese, R.; Solimeno, S.; Spinelli, N.

    1989-03-15

    Taking advantage of a new technique, we have monitored the relative variations of time duration and mode size as a function of the pulse energy for 30-ps-long Nd:YAG laser pulses. In particular, by carrying out a statistical analysis, we have observed that the pulse time duration is an increasing function of the pulse energy, according to the theoretical modeling of passively mode-locked lasers. The measurements can be easily extended to the femtosecond regime.

  2. Twitter's visual pulse

    OpenAIRE

    Hare, Jonathon; Samangooei, Sina; Dupplaw, David; Lewis, Paul H.

    2013-01-01

    Millions of images are tweeted every day, yet very little research has looked at the non-textual aspect of social media communication. In this work we have developed a system to analyse streams of image data. In particular we explore trends in similar, related, evolving or even duplicated visual artefacts in the mass of tweeted image data — in short, we explore the visual pulse of Twitter.

  3. Pulse Portraiture: Pulsar timing

    Science.gov (United States)

    Pennucci, Timothy T.; Demorest, Paul B.; Ransom, Scott M.

    2016-06-01

    Pulse Portraiture is a wideband pulsar timing code written in python. It uses an extension of the FFTFIT algorithm (Taylor 1992) to simultaneously measure a phase (TOA) and dispersion measure (DM). The code includes a Gaussian-component-based portrait modeling routine. The code uses the python interface to the pulsar data analysis package PSRCHIVE (ascl:1105.014) and also requires the non-linear least-squares minimization package lmfit (ascl:1606.014).

  4. STUCTURE OF PULSED BED

    Directory of Open Access Journals (Sweden)

    I. A. Bokun

    2014-01-01

    Full Text Available The structure of pulsed layer is proposed which can be suggested as a state of particulates that is blown by intermittent gas flow with speed which has the force to start material moving. Layer during one cycle is in a suspension, falling down and immobile state resulting in changes of particles arrangement as well as ways of gas flowing through layer. Moreover, it allows carrying out effective interphase heat exchange even adamant real granulation.The process of formation of impact flows is considered aw well as their influence on formation of air bubbles in pulsed layer. At startup of air blast the balance between the force of hydro-dynamic resistance is broken, on one side, and forces of gravity, particles inertia and their links with walls on the other side. The layer is transferred in the state of pulsed pseudo-fluidization, and presents gas-disperse mixture, inside of which impulse of pressure increasing is spreading to all sides as pressure waves (compression. These waves are the sources of impact flows’ formation, the force of which is two times more than during the stationary flow.The waves of pressure are divided into weak and strong ones depending on movement velocity within gas-disperse system. Weak waves are moving with a sound speed and strong ones in active phase of pulsed layer are moving over the speed of sound limit within gas-disperse system. The peculiarity of strong wave is that parameters of system (pressure, density and others are changing in discrete steps.The article describes the regime of layer’s falling down in the passive stage of cycle, which begins after finishing of gas impulse action. And suspension layer of moving up granular material is transferred in the state of falling resulting in change of the layer structure.

  5. Downhole pulse radar

    Science.gov (United States)

    Chang, Hsi-Tien

    1987-09-28

    A borehole logging tool generates a fast rise-time, short duration, high peak-power radar pulse having broad energy distribution between 30 MHz and 300 MHz through a directional transmitting and receiving antennas having barium titanate in the electromagnetically active region to reduce the wavelength to within an order of magnitude of the diameter of the antenna. Radar returns from geological discontinuities are sampled for transmission uphole. 7 figs.

  6. Ptychographic ultrafast pulse reconstruction

    CERN Document Server

    Spangenberg, D; Brügmann, M H; Feurer, T

    2014-01-01

    We demonstrate a new ultrafast pulse reconstruction modality which is somewhat reminiscent of frequency resolved optical gating but uses a modified setup and a conceptually different reconstruction algorithm that is derived from ptychography. Even though it is a second order correlation scheme it shows no time ambiguity. Moreover, the number of spectra to record is considerably smaller than in most other related schemes which, together with a robust algorithm, leads to extremely fast convergence of the reconstruction.

  7. PULSE Pilot Certification Results

    Directory of Open Access Journals (Sweden)

    Pamela Pape-Lindstrom

    2015-08-01

    Full Text Available The pilot certification process is an ambitious, nationwide endeavor designed to motivate important changes in life sciences education that are in line with the recommendations of the 2011 Vision and Change Report: A Call to Action (American Association for the Advancement of Science [AAAS], 2011.  It is the goal of the certification process to acknowledge departments that have progressed towards full implementation of the tenets of Vision and Change and to motivate departments that have not begun to adopt the recommendations to consider doing so.  More than 70 life science departments applied to be part of the pilot certification process, funded by a National Science Foundation grant, and eight were selected based on initial evidence of transformed and innovative educational practices.  The programs chosen represent a wide variety of schools, including two-year colleges, liberal-arts institutions, regional comprehensive colleges, research universities and minority serving institutions.  Outcomes from this pilot were released June 1, 2015 (www.pulsecommunity.org, with all eight programs being recognized as having progressed along a continuum of change.  Five levels of achievement were defined as PULSE Pilot Progression Levels.  Of the eight departments in the pilot, one achieved “PULSE Progression Level III: Accomplished”.  Six departments achieved “PULSE Progression Level II: Developing” and one pilot department achieved “PULSE Progression Level I: Beginning”.  All of the schools have made significant movement towards the recommendations of Vision and Change relative to a traditional life sciences curriculum.  Overall, the response from the eight pilot schools has been positive. 

  8. Petawatt pulsed-power accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Stygar, William A. (Albuquerque, NM); Cuneo, Michael E. (Albuquerque, NM); Headley, Daniel I. (Albuquerque, NM); Ives, Harry C. (Albuquerque, NM); Ives, legal representative; Berry Cottrell (Albuquerque, NM); Leeper, Ramon J. (Albuquerque, NM); Mazarakis, Michael G. (Albuquerque, NM); Olson, Craig L. (Albuquerque, NM); Porter, John L. (Sandia Park, NM); Wagoner; Tim C. (Albuquerque, NM)

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  9. Pulse Distributing Manifold; Pulse Distributing Manifold

    Energy Technology Data Exchange (ETDEWEB)

    Schutting, Eberhard [Technische Univ. Graz (Austria); Sams, Theodor [AVL List GmbH, Graz (Austria); Glensvig, Michael [Forschungsgesellschaft mbH, Graz (AT). Kompetenzzentrum ' ' Das virtuelle Fahrzeug' ' (VIF)

    2011-07-01

    The Pulse Distributing Manifold is a new charge exchange method for turbocharged diesel engines with exhaust gas recirculation (EGR). The method is characterized in that the EGR mass flow is not diverted from the exhaust gas mass flow continuously, but over time broken into sub-streams. The temporal interruption is achieved by two phase-shifted outlet valves which are connected via separate manifolds only with the turbocharger or only with the EGR path. The time points of valve opening are chosen such that the turbocharger and the aftertreatment process of exhaust gas is perfused by high-energy exhaust gas of the blowdown phase while cooler and less energy-rich exhaust gas of the exhaust period is used for the exhaust gas recirculation. This increases the enthalpy for the turbocharger and the temperature for the exhaust gas treatment, while the cooling efficiency at the EGR cooler is reduced. The elimination of the continuous EGR valve has a positive effect on pumping losses. The principle functioning and the potential of this system could be demonstrated by means of a concept study using one-dimensional simulations. Without disadvantages in fuel consumption for the considered commercial vehicle engine, a reduction the EGR cooler performance by 15 % and an increase in exhaust temperature of 35 K could be achieved. The presented charge exchange method was developed, evaluated and patented within the scope of the research program 'K2-mobility' of the project partners AVL (Mainz, Federal Republic of Germany) and University of Technology Graz (Austria). The research project 'K2-Mobility' is supported by the competence center 'The virtual vehicle' Forschungsgesellschaft mbH (Graz, Austria).

  10. High-speed pulse-shape generator, pulse multiplexer

    Science.gov (United States)

    Burkhart, Scott C.

    2002-01-01

    The invention combines arbitrary amplitude high-speed pulses for precision pulse shaping for the National Ignition Facility (NIF). The circuitry combines arbitrary height pulses which are generated by replicating scaled versions of a trigger pulse and summing them delayed in time on a pulse line. The combined electrical pulses are connected to an electro-optic modulator which modulates a laser beam. The circuit can also be adapted to combine multiple channels of high speed data into a single train of electrical pulses which generates the optical pulses for very high speed optical communication. The invention has application in laser pulse shaping for inertial confinement fusion, in optical data links for computers, telecommunications, and in laser pulse shaping for atomic excitation studies. The invention can be used to effect at least a 10.times. increase in all fiber communication lines. It allows a greatly increased data transfer rate between high-performance computers. The invention is inexpensive enough to bring high-speed video and data services to homes through a super modem.

  11. Coiled transmission line pulse generators

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Kenneth Fox (Columbia, MO)

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  12. A pulsed electron beam synthesis of PEDOT conducting polymers by using sulfate radicals as oxidizing species

    Science.gov (United States)

    Coletta, Cecilia; Cui, Zhenpeng; Dazzi, Alexandre; Guigner, Jean-Michel; Néron, Stéphane; Marignier, Jean-Louis; Remita, Samy

    2016-09-01

    In this study, an original radiolytic method, based on pulsed electron beam irradiation, is used for the synthesis of conducting PEDOT in an aqueous solution containing EDOT monomers in the presence of potassium persulfate, K2S2O8, at 0 °C. At this low temperature, EDOT monomers are not chemically oxidized by S2O82- anions, initiating PEDOT polymerization, but are rather oxidized by sulfate radicals, SO4•-, which are radiolytically generated by the reaction of solvated electrons, produced by water radiolysis, with persulfate anions. Successfully, as demonstrated by UV-vis absorption spectrophotometry and ATR-FTIR spectroscopy, irradiating the aqueous solution, by using a series of accumulated electron pulses, enables complete EDOT oxidation and quantitative in situ PEDOT polymerization through a step-by-step oxidation mechanism. The morphology of PEDOT polymers, mixed with unreacted K2S2O8 salt, is characterized by Cryo-TEM microscopy in aqueous solution and by SEM after deposition. Successfully, in the absence of any washing step, high resolution AFM microscopy, coupled with infrared nanospectroscopy, is used to discriminate between the organic polymers and the inorganic salt and to probe the local chemical composition of PEDOT nanostructures. The results demonstrate that PEDOT polymers form globular self-assembled nanostructures which preferentially adsorb onto unreacted K2S2O8 solid nanoplates. The present results first demonstrate the efficiency of sulfate radicals as oxidizing species for the preparation of nanostructured PEDOT polymers and second highlight the promising potentiality of electron accelerators in the field of conducting polymers synthesis.

  13. Green Light Pulse Oximeter

    Energy Technology Data Exchange (ETDEWEB)

    Scharf, John Edward (Oldsmar, FL)

    1998-11-03

    A reflectance pulse oximeter that determines oxygen saturation of hemoglobin using two sources of electromagnetic radiation in the green optical region, which provides the maximum reflectance pulsation spectrum. The use of green light allows placement of an oximetry probe at central body sites (e.g., wrist, thigh, abdomen, forehead, scalp, and back). Preferably, the two green light sources alternately emit light at 560 nm and 577 nm, respectively, which gives the biggest difference in hemoglobin extinction coefficients between deoxyhemoglobin, RHb, and oxyhemoglobin, HbO.sub.2.

  14. Pulsed differential pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, G.N.; Bagautdinov, F.A.; Rybalov, S.V.

    1985-06-01

    A pulsed differential pumping system is described for extracting an electron beam from a shaping region at a pressure of 10/sup -5/ torr into a volume with a pressure of 10-100 torr. A fast valve is used with appropriate geometrical parameters to reduce the length of the outlet channel considerable while increasing its diameter. Test results are given. The pumping system has two sections which communicate one with the other and with the volume at the elevated pressure which is produced by gasdynamic nozzles.

  15. Pulse Field Gel Electrophoresis.

    Science.gov (United States)

    Sharma-Kuinkel, Batu K; Rude, Thomas H; Fowler, Vance G

    2016-01-01

    Pulse Field Gel Electrophoresis (PFGE) is a powerful genotyping technique used for the separation of large DNA molecules (entire genomic DNA) after digesting it with unique restriction enzymes and applying to a gel matrix under the electric field that periodically changes direction. PFGE is a variation of agarose gel electrophoresis that permits analysis of bacterial DNA fragments over an order of magnitude larger than that with conventional restriction enzyme analysis. It provides a good representation of the entire bacterial chromosome in a single gel with a highly reproducible restriction profile, providing clearly distinct and well-resolved DNA fragments.

  16. A Pulsed Sphere Tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, Dermott E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-01-30

    Here I attempt to explain what physically happens when we pulse an object with neutrons, specifically what we expect the time dependent behavior of the neutron population to look like. Emphasis is on the time dependent emission of both prompt and delayed neutrons. I also describe how the TART Monte Carlo transport code models this situation; see the appendix for a complete description of the model used by TART. I will also show that, as we expect, MCNP and MERCURY, produce similar results using the same delayed neutron model (again, see the appendix).

  17. COMPUTER BASED HEART PULSES MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Ali N. Hamoodi

    2013-05-01

    Full Text Available In this work the measurement and displays of blood oxygen saturation and pulse rate are investigated practically using computer.The analysis involves the variation in blood oxygen saturation ratio and pulse rate. The results obtained are compared with kontron pulse oximeter 7840 device. The value obtained for the same person pulse rate is approximately equal to that obtained by the konton pulse oximeter 7840 device. The sensor used in this work is the finger clip.The advantages of using computer over kontron pulse oximeter 7840 device is that the data of the patient can be saved in the computer for many years and also it can be display at any time so that the doctor get file contains all data for each patient. 

  18. Angular momentum of sound pulses.

    Science.gov (United States)

    Lekner, John

    2006-07-05

    Three-dimensionally localized acoustic pulses in an isotropic fluid medium necessarily have transverse components of momentum density. Those with an azimuthal component of momentum density can carry angular momentum. The component of total pulse angular momentum along the direction of the total momentum is an invariant (constant in time and independent of choice of origin). The pulse energy, momentum and angular momentum are evaluated analytically for a family of localized solutions of the wave equation. In the limit where the pulses have many oscillations within their spatial extent ([Formula: see text], where k is the wavenumber and a determines the size of a pulse), the energy, momentum and angular momentum are consistent with a multiphonon representation of the pulse, each phonon having energy [Formula: see text], momentum [Formula: see text] and angular momentum [Formula: see text] (with integer m).

  19. Bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  20. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  1. Assembly delay line pulse generators

    CERN Document Server

    1971-01-01

    Assembly of six of the ten delay line pulse generators that will power the ten kicker magnet modules. One modulator part contains two pulse generators. Capacitors, inductances, and voltage dividers are in the oil tank on the left. Triggered high-pressure spark gap switches are on the platforms on the right. High voltage pulse cables to the kicker magnet emerge under the spark gaps. In the centre background are the assembled master gaps.

  2. Multi pulse control of entanglement

    CERN Document Server

    Uchiyama, C; Uchiyama, Chikako; Aihara, Masaki

    2004-01-01

    We study the effectiveness of multi pulse control to suppress the degradation of entanglement. Based on a linearly interacting spin-boson model, we show that the multi pulse application recovers the decay of concurrence when an entangled pair of spins interacts with a reservoir that has the non-Markovian nature. We present the effectiveness of multi pulse control for both the common bath case and the individual bath case.

  3. Analysis of Pulse Modulated Control Systems (Ⅲ) Stability of Systems with Pulse Frequency Modulation and Systems with Combined Pulse Frequency and Pulse Width Modulation

    OpenAIRE

    OI,Shigemitsu

    1993-01-01

    Sufficient conditions for finite pulse stability of interconnected systems with combined pulse frequency and pulse width modulation are developed in this paper using a direct method. The stability criteria established provide upper bounds on the number of pulses emitted by each modulator. The results are also applicable to those systems which contain a finite number of pulse frequency modulators and a finite number of combined pulse frequency and pulse width modulators

  4. Population inversion by chirped pulses

    Energy Technology Data Exchange (ETDEWEB)

    Lu Tianshi [Department of Mathematics and Statistics, Wichita State University, Wichita, Kansas 67260-0033 (United States)

    2011-09-15

    In this paper, we analyze the condition for complete population inversion by a chirped pulse over a finite duration. The nonadiabatic transition probability is mapped in the two-dimensional parameter space of coupling strength and detuning amplitude. Asymptotic forms of the probability are derived by the interference of nonadiabatic transitions for sinusoidal and triangular pulses. The qualitative difference between the maps for the two types of pulses is accounted for. The map is used for the design of stable inversion pulses under specific accuracy thresholds.

  5. Double pulse laser wakefield accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Changbum [Department of Physics, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)], E-mail: chbkim@postech.ac.kr; Kim, Jin-Cheol B. [Department of Physics, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Kim, Kukhee [National Fusion Reserch Center, Daejeon 305-333 (Korea, Republic of); Ko, In Soo [Department of Physics, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Suk, Hyyong [Center for Advanced Accelerators, Korea Electrotechnology Research Institute, Changwon 641-120 (Korea, Republic of)

    2007-10-22

    Two-dimensional simulation studies are performed for modified laser wakefield acceleration. After one laser pulse, another identical laser pulse is sent to the plasma to amplify the wake wave resonantly. The simulation results show that the number of injected electrons is bigger than that of the single pulse case and the beam energy is higher as well. In addition, increase of the transverse amplitude is noticed in the wake wave after the second laser pulse. This shows that the transverse motion of the wake wave enhances the wave breaking for strong injection and acceleration of electron beams.

  6. Pulse oximetry in severe anaemia

    DEFF Research Database (Denmark)

    Ramsing, T; Rosenberg, J

    1992-01-01

    Measurement of arterial oxygen saturation by pulse oximetry was performed in two patients with acute and chronic anaemia (haemoglobin concentrations: 2.9 mmol/l (4.7 g/dl) and 1.9 mmol/l (3.0 g/dl), respectively) using a Radiometer OXI and a Nellcor N-200 pulse oximeter. The two oximeters read...... alternating different values in the two patients. In conclusion, pulse oximeters are able to give a value for oxygen saturation even at extreme anaemia, and when a high value is given, it possibly reflects arterial oxygen saturation. The value of pulse oximetry in severe anaemia is discussed....

  7. Theoretical Studies of the Output Pulse with Variation of the Pumping Pulse for RF Excited CO2 Pulsed Waveguide Laser

    Institute of Scientific and Technical Information of China (English)

    A Rauf; ZHOU Wei; XIN Jian-guo

    2006-01-01

    The behavior of a RF-excited waveguide CO2 laser in the pulse regime is studied theoretically. The output pulse evolution is studied by applying three types of pulses namely the square, sine and the triangular ones as the excitation pulses. The frequency dependence behavior of the output pulse is also presented.

  8. Pulse-shaping strategies in short-pulse fiber amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Schimpf, Damian Nikolaus

    2010-02-09

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  9. Pulsed plasma arc cladding

    Institute of Scientific and Technical Information of China (English)

    龙; 白钢; 李振民; 张赋升; 杨思乾

    2004-01-01

    A prototype of Pulsed Plasma Arc Cladding system was developed, in which single power source supplies both transferred plasma arc (TPA) and non-transferred plasma arc (N-TPA). Both plasmas work in turn in a high frequency controlled by an IGBT connecting nozzle and workpiece. The working frequency of IGBT ranges from 50 ~ 7000Hz, in which the plasmas can work in turn smoothly. Higher than 500 Hz of working frequency is suggested for promotion of cladding quality and protection of IGBT. Drag phenomenon of TPA intensifies as the frequency goes up, which tends to increase the current proportion of TPA and suppress N-TPA. The occupation ratio of IGBT can be regulated from 5% ~ 95%, which balances the power supplies of both plasmas. An occupation ratio higher than 50% gives adequate proportion of arc current for N-TPA to preheat powder.

  10. Nanofabrication with Pulsed Lasers

    Directory of Open Access Journals (Sweden)

    Kabashin AV

    2010-01-01

    Full Text Available Abstract An overview of pulsed laser-assisted methods for nanofabrication, which are currently developed in our Institute (LP3, is presented. The methods compass a variety of possibilities for material nanostructuring offered by laser–matter interactions and imply either the nanostructuring of the laser-illuminated surface itself, as in cases of direct laser ablation or laser plasma-assisted treatment of semiconductors to form light-absorbing and light-emitting nano-architectures, as well as periodic nanoarrays, or laser-assisted production of nanoclusters and their controlled growth in gaseous or liquid medium to form nanostructured films or colloidal nanoparticles. Nanomaterials synthesized by laser-assisted methods have a variety of unique properties, not reproducible by any other route, and are of importance for photovoltaics, optoelectronics, biological sensing, imaging and therapeutics.

  11. Nanosecond Pulse Technique

    Science.gov (United States)

    1989-03-17

    tunnel diodes, to ferrites, etc.) and to the need for the review of the methods of formation and converting the pulses, to a considerable degree...4n3l) 0 1 + 4n 21)2 + (4n2l) (.84) _ 4 nf tl 5 (I - 4n12/) 2 - (4nil)’ (1.85) " ( - 2o) l - 4’n2% 2 I3 (I + 4n =2/)2 + ( 41a2 )’ -arg + 4ni,21. + j4na,tJ...recirculator is borrowed from the article of Yu. I. Neymark, Yu. K. Maklakov and L. P. Yelkins [105]. ENDFOOTNOTE. DOC = 88076720 PAGE d a) t l I t S6) t�t

  12. Nanofabrication with pulsed lasers.

    Science.gov (United States)

    Kabashin, Av; Delaporte, Ph; Pereira, A; Grojo, D; Torres, R; Sarnet, Th; Sentis, M

    2010-02-24

    An overview of pulsed laser-assisted methods for nanofabrication, which are currently developed in our Institute (LP3), is presented. The methods compass a variety of possibilities for material nanostructuring offered by laser-matter interactions and imply either the nanostructuring of the laser-illuminated surface itself, as in cases of direct laser ablation or laser plasma-assisted treatment of semiconductors to form light-absorbing and light-emitting nano-architectures, as well as periodic nanoarrays, or laser-assisted production of nanoclusters and their controlled growth in gaseous or liquid medium to form nanostructured films or colloidal nanoparticles. Nanomaterials synthesized by laser-assisted methods have a variety of unique properties, not reproducible by any other route, and are of importance for photovoltaics, optoelectronics, biological sensing, imaging and therapeutics.

  13. Pulsed plasma electron sourcesa)

    Science.gov (United States)

    Krasik, Ya. E.; Yarmolich, D.; Gleizer, J. Z.; Vekselman, V.; Hadas, Y.; Gurovich, V. Tz.; Felsteiner, J.

    2009-05-01

    There is a continuous interest in research of electron sources which can be used for generation of uniform electron beams produced at E ≤105 V/cm and duration ≤10-5 s. In this review, several types of plasma electron sources will be considered, namely, passive (metal ceramic, velvet and carbon fiber with and without CsI coating, and multicapillary and multislot cathodes) and active (ferroelectric and hollow anodes) plasma sources. The operation of passive sources is governed by the formation of flashover plasma whose parameters depend on the amplitude and rise time of the accelerating electric field. In the case of ferroelectric and hollow-anode plasma sources the plasma parameters are controlled by the driving pulse and discharge current, respectively. Using different time- and space-resolved electrical, optical, spectroscopical, Thomson scattering and x-ray diagnostics, the parameters of the plasma and generated electron beam were characterized.

  14. Micro pulse lidar

    Science.gov (United States)

    Spinhirne, James D.

    1993-01-01

    An eye safe, compact, solid state lidar for profiling atmospheric cloud and aerosol scattering has been demonstrated. The transmitter of the micropulse lidar is a diode pumped micro-J pulse energy, high repetition rate Nd:YLF laser. Eye safety is obtained through beam expansion. The receiver employs a photon counting solid state Geiger mode avalanche photodiode detector. Data acquisition is by a single card multichannel scaler. Daytime background induced quantum noise is controlled by a narrow receiver field-of-view and a narrow bandwidth temperature controlled interference filter. Dynamic range of the signal is limited by optical geometric signal compression. Signal simulations and initial atmospheric measurements indicate that systems built on the micropulse lidar concept are capable of detecting and profiling all significant cloud and aerosol scattering through the troposphere and into the stratosphere. The intended applications are scientific studies and environmental monitoring which require full time, unattended measurements of the cloud and aerosol height structure.

  15. Capacitor discharge pulse analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Michael Sean; Griffiths, Stewart K.; Tanner, Danelle Mary

    2013-08-01

    Capacitors used in firing sets and other high discharge current applications are discharge tested to verify performance of the capacitor against the application requirements. Parameters such as capacitance, inductance, rise time, pulse width, peak current and current reversal must be verified to ensure that the capacitor will meet the application needs. This report summarizes an analysis performed on the discharge current data to extract these parameters by fitting a second-order system model to the discharge data and using this fit to determine the resulting performance metrics. Details of the theory and implementation are presented. Using the best-fit second-order system model to extract these metrics results in less sensitivity to noise in the measured data and allows for direct extraction of the total series resistance, inductance, and capacitance.

  16. Template Reproduction of GRB Pulse Light Curves

    Science.gov (United States)

    Hakkila, Jon E.; Preece, R. D.; Loredo, T. J.; Wolpert, R. L.; Broadbent, M. E.

    2014-01-01

    A study of well-isolated pulses in gamma ray burst light curves indicates that simple models having smooth and monotonic pulse rises and decays are inadequate. Departures from the Norris et al. (2005) pulse shape are in the form of a wave-like pre-peak residual that is mirrored and stretched following the peak. Pulse shape departures are present in GRB pulses of all durations, but placement of the departures relative to pulse peaks correlates with asymmetry. This establishes an additional link between temporal structure and spectral evolution, as pulse asymmetry is related to initial hardness while pulse duration indicates the rate of hard-to-soft pulse evolution.

  17. Research agenda shrimp pulse fishery

    NARCIS (Netherlands)

    Marlen, van B.; Rasenberg, M.M.M.; Verschueren, B.; Polet, H.

    2015-01-01

    In the recent decennia, many developments have taken place to improve the selectivity of the shrimp fishing gears. Recently, the development of a pulse gear for catching shrimps has taken up again as an opportunity to decrease discards, inspired by developments in the flatfish pulse fishery.

  18. Pulse oximetry for perioperative monitoring

    DEFF Research Database (Denmark)

    Pedersen, Tom; Møller, Ann Merete; Hovhannisyan, Karen

    2009-01-01

    Pulse oximetry is extensively used in the perioperative period and might improve patient outcomes by enabling an early diagnosis and, consequently, correction of perioperative events that might cause postoperative complications or even death. Only a few randomized clinical trials of pulse oximetry...

  19. A Single-Pulse Integrator

    DEFF Research Database (Denmark)

    Miller, Arne

    1974-01-01

    A single-pulse integrator is described. It gives a relative measure of the integral of the output signal from a coil monitor on the Risø 10 MeV linear accelerator, and displays the value on a digital voltmeter. The reproduccibility is found to be better than ±1% for an accelerated pulse charge...

  20. NMR in pulsed magnetic field

    KAUST Repository

    Abou-Hamad, Edy

    2011-09-01

    Nuclear magnetic resonance (NMR) experiments in pulsed magnetic fields up to 30.4 T focused on 1H and 93Nb nuclei are reported. Here we discuss the advantage and limitation of pulsed field NMR and why this technique is able to become a promising research tool. © 2011 Elsevier Inc. All Rights Reserved.

  1. Dexamethasone pulse therapy in pemphigus

    NARCIS (Netherlands)

    Toth, GG; van de Meer, JB; Jonkman, MF

    2002-01-01

    Pulse therapy with high-dose glucocorticoids was introduced 20 years ago as a treatment modality for autoimmune disease and transplant rejection. The most popular dermatological indication for pulse therapy is severe pemphigus. We reviewed the sequelae of 14 patients with pemphigus who were treated

  2. Pulse oximetry for perioperative monitoring

    DEFF Research Database (Denmark)

    Pedersen, Tom; Nicholson, Amanda; Hovhannisyan, Karen

    2014-01-01

    . Results indicated that hypoxaemia was reduced in the pulse oximetry group, both in the operating theatre and in the recovery room. During observation in the recovery room, the incidence of hypoxaemia in the pulse oximetry group was 1.5 to three times less. Postoperative cognitive function was independent...... postoperative complications or even death. Only a few randomized clinical trials of pulse oximetry during anaesthesia and in the recovery room have been performed that describe perioperative hypoxaemic events, postoperative cardiopulmonary complications and cognitive dysfunction. OBJECTIVES: To study the use...... checked the reference lists of trials and review articles. The original search was performed in January 2005, and a previous update was performed in May 2009. SELECTION CRITERIA: We included all controlled trials that randomly assigned participants to pulse oximetry or no pulse oximetry during...

  3. Neurostimulation using subnanosecond electric pulses

    Science.gov (United States)

    Xiao, Shu; Pakhomov, Andrei; Guo, Fei; Polisetty, Swetha; Schoenbach, Karl H.

    2013-02-01

    We have for the first time recorded action potentials in rat hippocampus neurons when they were stimulated by subnanosecond electric pulses. The preliminary results show that applying a series of pulses allowed the accumulation of depolarization before activating the voltage gated channels. The depolarization only occurred when the electric pulses were applied. It is unclear whether the depolarization is caused by the charge accumulation across the membrane or the cation influx due to the membrane permeabilization. We have also conducted an electromagnetic simulation of delivering subnanosecond pulses to tissues using an impulse radiating antenna. The results show that the pulses can be confined in the deep region in the brain but the amplitude is reduced significantly due to the attenuation of the tissues. A partially lossy dielectric lens may be used to reverse the decreasing trend of the electric field.

  4. Pre-earthquake Magnetic Pulses

    CERN Document Server

    Scoville, John; Freund, Friedemann

    2014-01-01

    A semiconductor model of rocks is shown to describe unipolar magnetic pulses, a phenomenon that has been observed prior to earthquakes. These pulses are observable because their extremely long wavelength allows them to pass through the Earth's crust. Interestingly, the source of these pulses may be triangulated to pinpoint locations where stress is building deep within the crust. We couple a semiconductor drift-diffusion model to a magnetic field in order to describe the electromagnetic effects associated with electrical currents flowing within rocks. The resulting system of equations is solved numerically and it is seen that a volume of rock may act as a diode that produces transient currents when it switches bias. These unidirectional currents are expected to produce transient unipolar magnetic pulses similar in form, amplitude, and duration to those observed before earthquakes, and this suggests that the pulses could be the result of geophysical semiconductor processes.

  5. Pulse radiolysis studies of intramolecular electron transfer in model peptides and proteins. 7. Trp -> TyrO radical transformation in hen egg-white lysozyme. Effects of pH, temperature, Trp62 oxidation and inhibitor binding

    DEFF Research Database (Denmark)

    Bobrowski, K.; Holcman, J.; Poznanski, J.

    1997-01-01

    (.). Arrhenius plots of the temperature-dependence of k(5) showed that the activation energy of LRET varies both with temperature and the protonation state of the enzyme. The activation energies are in the range 7.6-56.0 kJ mol(-1) and are similar to those for activation of amide hydrogen exchange in native HEWL...... below its denaturation temperature. Selective oxidation by ozone of the Trp62 indole side-chain in HEWL to N'-formylkynurenine (NFKyn62-HEWL) caused a large drop in the initial yield of Trp(.) radicals, G(Trp(.))(i). This was accompanied by a relatively small decrease in k(5) but selective oxidation...... by ozone had a pronounced effect on its temperature-dependence. Taken together these observations indicate that of the six tryptophans present in HEWL Trp62 contributes about 50% to the yield of the observed LRET. In the enzyme-inhibitor complex, HEWL(GlcNAc)(3), where Trp62 and Trp63 are completely...

  6. Pulse shaping using a spatial light modulator

    CSIR Research Space (South Africa)

    Botha, N

    2009-07-01

    Full Text Available Femtosecond pulse shaping can be done by different kinds of pulse shapers, such as liquid crystal spatial light modulators (LC SLM), acousto optic modulators (AOM) and deformable and movable mirrors. A few applications where pulse shaping...

  7. Pulse source requirements for OTDM systems

    DEFF Research Database (Denmark)

    Clausen, Anders; Poulsen, Henrik Nørskov; Oxenløwe, Leif Katsuo

    2003-01-01

    A simulation model for investigating the impact of incoherent crosstalk due to pulse tail overlapping is proposed. Requirements to pulse width and pulse tail extinction ratio introducing a maximum of 1 dB penalty is extracted....

  8. Pulse radiolytic studies on cis-dichlorobis(1,10-phenanthroline-5,6-dione)Cobalt(III) complex

    Indian Academy of Sciences (India)

    Vitthal A Kawade; Smita Ghosh; Avinash V Sapre; Avinash S Kumbhar

    2010-03-01

    Reactions of four reducing radical species namely $e^{-}_{\\text{aq}}$, H-atoms, (CH3)$_{2}^{\\bullet}$COH and $^{\\bullet}$CO$^-_2$ radicals with [Co(III)(phendione)2Cl2]Cl (complex) have been studied by electron pulse radiolysis. Time resolved transient absorption spectra for all the four species show two peaks which match with those of phendione anion radical produced by the reaction of e$^{-}_{\\text{aq}}$ with phendione. However, there are some differences in the spectral and kinetic features in the reactions of H-atoms and $^{\\bullet}CO^{-}_{2}$ radicals with the complex which are elaborated. Steady state absorption spectra on irradiation under reducing conditions indicate breakdown of the complex. The anion radical initially produced has fairly long lifetime of few 100 microseconds. Spectral studies show that initial site of attack for electron transfer is the phendione moiety. Subsequently the electron is transferred to other sites resulting in aquation/decomposition to metal ion. Conductometric studies show that conductance substantially increases on irradiation and could be attributed to aquation/de-ligation of the complex by intramolecular electron transfer.

  9. The {gamma} radiolysis at room temperature of liquid deaerated isopropanol; Radiolyse {gamma} a temperature ambiante de l'isopropanol liquide desaere

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, L. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-02-01

    The main products formed in the room temperature {gamma} radiolysis of liquid isopropanol, and their respective yields, are: hydrogen 3.8, methane 1.6, acetone 3.4, acetaldehyde 1.1, and pinacol 0.3. These results give a material balance in good agreement with the formula of isopropanol and lead to a value for the yield of decomposition: 5, 3. The absence of butanediol 2.3 shows that the acetaldehyde cannot come from the dismutation of hydroxyethyl radicals. The variations of the hydrogen yield in the neutral medium with the concentration of added electron scavengers may be explained in terms of the model proposed by Freeman and FAYADH which supposes the existence of spurs. The yield of solvated electrons diffusing into the bulk of the solution and also the ratios of rate constants for the reactions of the scavengers with the electrons may likewise be obtained on the basis of this model. Certain effects not foreseen by this model may result from the capture of electrons solvated or not, whose mode of disappearance in pure alcohol remains unknown. One may distinguish a yield of excited molecules of at least 2, of which 80 per cent lead to the production of molecular hydrogen and 20 per cent to that of molecular methane, and an ionization yield of 2. 2. The discussion of the various mechanisms which may lead to the formation of the products indicates that these yields may be higher than the values quoted. (author) [French] Les principaux produits formes a temperature ambiante dans la radiolyse {gamma} de l'isopropanol liquide sont: l'hydrogene, le methane, l'acetone, l'acetaldehyde et le pinacol avec des rendements respectifs de 3,8 - 1,6 - 3,4 - 1,1 - 0,3. Le bilan de masse deduit de ces resultats est en bon accord avec la formule brute de l'isopropanol dont le rendement de decomposition est 5,3. L'absence de butanediol 2,3 montre que l'acetaldehyde ne peut provenir de la reaction de dismutation des radicaux hydroxyethyles. Le

  10. Bomb pulse biology

    Energy Technology Data Exchange (ETDEWEB)

    Falso, Miranda J. Sarachine [Center for Accelerator Mass Spectrometry, Mail Stop L-397, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States); Buchholz, Bruce A., E-mail: buchholz2@llnl.gov [Center for Accelerator Mass Spectrometry, Mail Stop L-397, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States)

    2013-01-15

    The past decade has seen an explosion in use of the {sup 14}C bomb pulse to do fundamental cell biology. Studies in the 1960s used decay counting to measure tissue turnover when the atmospheric {sup 14}C/C concentration was changing rapidly. Today bulk tissue measurements are of marginal interest since most of the carbon in the tissue resides in proteins, lipids and carbohydrates that turn over rapidly. Specific cell types with specialized functions are the focus of cell turnover investigations. Tissue samples need to be fresh or frozen. Fixed or preserved samples contain petroleum-derived carbon that has not been successfully removed. Cell or nuclear surface markers are used to sort specific cell types, typically by fluorescence-activated cell sorting (FACS). Specific biomolecules need to be isolated with high purity and accelerator mass spectrometry (AMS) measurements must accommodate samples that generally contain less than 40 {mu}g of carbon. Furthermore, all separations must not add carbon to the sample. Independent means such as UV absorbance must be used to confirm molecule purity. Approaches for separating specific proteins and DNA and combating contamination of undesired molecules are described.

  11. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1990-01-01

    Electrostatic collection of a high resistivity aerosol using the Electron Beam Precipitator (EBP) collecting section was demonstrated during this reporting period (Quarter Five). Collection efficiency experiments were designed to confirm and extend some of the work performed under the previous contract. The reason for doing this was to attempt to improve upon the collection efficiency of the precipitator alone when testing with a very high resistivity, moderate-to-high concentration dust load. From the collector shakedown runs, a set of suitable operational parameters were determined for the downstream electrostatic collecting sections of the Electron Beam Precipitator wind tunnel. These parameters, along with those for the MINACC electron beam, will generally be held constant while the numerous precharging parameters are varied to produce an optimum particle charge. The electrostatic collector experiments were part of a larger, comprehensive investigation on electron beam precharging of high resistivity aerosol particles performed during the period covered by Quarters Five, Six, and Seven. This body of work used the same experimental apparatus and procedures and the experimental run period lasted nearly continuously for six months. A summary of the Quarter Five work is presented in the following paragraphs. Section II-A of TPR 5 contains a report on the continuing effort which was expended on the modification and upgrade of the pulsed power supply and the monitoring systems prior to the initiation of the electron beam precharging experimental work.

  12. Interaction study of water radiolysis products with Crotalus durissus terrificus miotoxin; Estudo das interacoes dos produtos de radiolise da agua com a miotoxina do veneno de Crotalus durissus terrificus

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Murilo Casare da

    2008-07-01

    Ionizing radiation has been satisfactorily employed for venoms detoxification. In this report, the radiation was employed to verify the effects caused by the radiolysis products of water on the Crotamine, toxin purified from Crotalus durissus terrificus venom. These effects were analyzed using some substances called 'scavengers', those substances competes for specific reactive species hindering them to act on the toxins molecules. In order to study the possible structural damages caused on the toxins, circular dichroism, fluorescence, nuclear magnetic resonance, amino acids analysis and intravital microscopy were employed. Our results indicate that ionizing radiation caused structure alterations, mainly, in secondary and tertiary structure of crotamine. In the irradiated crotamine, was not possible to determine tridimensional structure. And the crotamine toxic effect was removed by ionizing radiation. (author)

  13. Magnetic Alignment of Pulsed Solenoids Using the Pulsed Wire Method

    Energy Technology Data Exchange (ETDEWEB)

    Arbelaez, D.; Madur, A.; Lipton, T.M.; Waldron, W.L.; Kwan, J.W.

    2011-04-01

    A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 {micro}m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.

  14. Causality effects on accelerating light pulses

    National Research Council Canada - National Science Library

    Kaminer, Ido; Lumer, Yaakov; Segev, Mordechai; Christodoulides, Demetrios N

    2011-01-01

    .... We explore the effects of causality, and find that, whereas decelerating pulses can asymptotically reach zero group velocity, pulses that accelerate towards infinite group velocity inevitably break...

  15. Pulsed ultrasonic stir welding method

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    A method of performing ultrasonic stir welding uses a welding head assembly to include a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. In the method, the rod is rotated about its longitudinal axis during a welding operation. During the welding operation, a series of on-off ultrasonic pulses are applied to the rod such that they propagate parallel to the rod's longitudinal axis. At least a pulse rate associated with the on-off ultrasonic pulses is controlled.

  16. Hyper dispersion pulse compressor for chirped pulse amplification systems

    Science.gov (United States)

    Barty, Christopher P. J.

    2011-11-29

    A grating pulse compressor configuration is introduced for increasing the optical dispersion for a given footprint and to make practical the application for chirped pulse amplification (CPA) to quasi-narrow bandwidth materials, such as Nd:YAG. The grating configurations often use cascaded pairs of gratings to increase angular dispersion an order of magnitude or more. Increased angular dispersion allows for decreased grating separation and a smaller compressor footprint.

  17. Pulse-to-pulse Diagnostics at High Reprate

    Science.gov (United States)

    Green, Bertram; Kovalev, Sergey; Golz, Torsten; Stojanovich, Nikola; Fisher, Alan; Kampfrath, Tobias; Gensch, Michael

    2016-03-01

    Femtosecond level diagnostic and control of sub-picosecond electron bunches is an important topic in modern accelerator research. At the same time new linear electron accelerators based on quasi-CW SRF technology will be the drivers of many future 4th Generation lightsources such as X-ray free electron lasers. A high duty cycle, high stability and online pulse to pulse diagnostic at these new accelerators are crucial ingredients to the success of these large scale facilities. A novel THz based online monitor concept is presented that has the potential to give access to pulse to pulse information on bunch form, arrival time and energy at high repetition rate and down to sub pC charges. We furthermore show experimentally that pulse to pulse arrival time measurements can be used to perform pump-probe experiments with a temporal resolution in the few-fs regime and an exceptional dynamic range. Our scheme has been tested at the superradiant test facility TELBE, but can be readily transferred to other SRF accelerator driven photon sources, such as X-FELs.

  18. Pulsed light and pulsed electric field for foods and eggs.

    Science.gov (United States)

    Dunn, J

    1996-09-01

    Two new technologies for use in the food industry are described. The first method discussed uses intense pulse of light. This pulsed light (PureBright) process uses short duration flashes of broad spectrum "white" light to kill all exposed microorganisms, including vegetative bacteria, microbial and fungal spores, viruses, and protozoan oocysts. Each pulse, or flash, of light lasts only a few hundred millionths of a second (i.e., a few hundred microseconds). The intensity of each flash of light is about 20,000 times the intensity of sunlight at the earth's surface. The flashes are typically applied at a rate of about one to tens of flashes per second. For most applications, a few flashes applied in a fraction of a second provide an effective treatment. High microbial kill can be achieved, for example, on the surfaces of packaging materials, on packaging and processing equipment, foods, and medical devices as well as on many other surfaces. In addition, some bulk materials such as water and air that allow penetration of the light can be sterilized. The results of tests to measure the effects of pulsed light on Salmonella enteritiditis on eggs are presented. The second method discussed uses multiple, short duration, high intensity electric field pulses to kill vegetative microorganisms in pumpable products. This pulsed electric field (or CoolPure) process can be applied at modest temperatures at which no appreciable thermal damage occurs and the original taste, color, texture, and functionality of products can be retained.

  19. Treatment of Persistent Facial Postinflammatory Hyperpigmentation With Novel Pulse-in-Pulse Mode Intense Pulsed Light.

    Science.gov (United States)

    Park, Ji-Hye; Kim, Jung-In; Kim, Won-Serk

    2016-02-01

    Postinflammatory hyperpigmentation (PIH) is an acquired hypermelanosis induced by various causes including inflammatory dermatoses, injury, or cosmetic procedures, such as lasers or chemical peels, and it tends to affect dark-skinned people with greater frequency and severity. There are a variety of treatment options for PIH, including topical agents, chemical peels, laser, and light therapy. However, the results are not up to expectation. The purpose of this study was to examine the clinical efficacy and safety of novel pulse-in-pulse mode intense pulsed light (IPL) for the treatment of persistent facial PIH in Korean patients. Twenty-five Korean female patients (Fitzpatrick skin types III-V) with persistent facial PIH were enrolled in the study. The patients were treated with novel pulse-in-pulse mode IPL for 4 sessions at 1-week interval and 4 sessions at 2-week intervals. Treatment efficacy and patient satisfaction were evaluated using photographs and questionnaires. After 2 months of all treatments, 23 patients (92%) had more than 50% improvement and 22 patients (88%) were satisfied with the treatments. No adverse effects or aggravations were reported. The pulse-in-pulse mode IPL treatment is effective and safe for persistent facial PIH in dark-skinned patients.

  20. Intense pulsed neutron source

    Science.gov (United States)

    The IPNS Progress Report 10th Anniversary Edition is being published in recognition of the first ten years of successful IPNS operation. To emphasize the significance of this milestone, we wanted this report to stand apart from the previous IPNS Progress Reports, and the best way to do this, we thought, was to make the design and organization of the report significantly different. In their articles, authors were asked to emphasize not only advances made since IPNS began operating but also the groundwork that was laid at its predecessor facilities - Argonne's ZING-P and ZING-P' prototype pulsed neutron sources and CP-5 reactor. Each article stands as a separate chapter in the report, since each represents a particular instrument or class of instruments, system, technique, or area of research. In some cases, contributions were similar to review articles in scientific journals, complete with extensive lists of references. Ten-year cumulative lists of members of IPNS committees and of scientists who have visited or done experiments at IPNS were assembled. A list of published and 'in press' articles in journals, books, and conference proceedings, resulting from work done at IPNS during the past ten years, was compiled. And archival photographs of people and activities during the ten-year history of IPNS were located and were used liberally throughout the report. The titles of the chapters in this report are: accelerator; computer; radiation effects; powder; stress; single crystal; superconductivity; amorphous; small angle; reflection; quasielastic; inelastic; inelastic magnetic; deep inelastic; user program; the future; and publications.

  1. Next generation Chirped Pulse Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Nees, J.; Biswal, S.; Mourou, G. [Univ. Michigan, Center for Ultrafast Optical Science, Ann Arbor, MI (United States); Nishimura, Akihiko; Takuma, Hiroshi

    1998-03-01

    The limiting factors of Chirped Pulse Amplification (CPA) are discussed and experimental results of CPA in Yb:glass regenerative amplifier are given. Scaling of Yb:glass to the petawatt level is briefly discussed. (author)

  2. Rapidly pulsed helium droplet source

    Energy Technology Data Exchange (ETDEWEB)

    Pentlehner, Dominik; Riechers, Ricarda; Dick, Bernhard; Slenczka, Alkwin [Institute for Physical and Theoretical Chemistry, University of Regensburg, 93053 Regensburg (Germany); Even, Uzi; Lavie, Nachum; Brown, Raviv; Luria, Kfir [Sackler Faculty of Exact Sciences, School of Chemistry, Tel Aviv University, Ramat Aviv, 69978 Tel Aviv (Israel)

    2009-04-15

    A pulsed valve connected to a closed-cycle cryostat was optimized for producing helium droplets. The pulsed droplet beam appeared with a bimodal size distribution. The leading part of the pulse consists of droplets suitable for doping with molecules. The average size of this part can be varied between 10{sup 4} and 10{sup 6} helium atoms, and the width of the distribution is smaller as compared to a continuous-flow droplet source. The system has been tested in a single pulse mode and at repetition rates of up to 500 Hz with almost constant intensity. The droplet density was found to be increased by more than an order of magnitude as compared to a continuous-flow droplet source.

  3. Low-noise pulse conditioner

    Science.gov (United States)

    Bird, D.A.

    1981-06-16

    A low-noise pulse conditioner is provided for driving electronic digital processing circuitry directly from differentially induced input pulses. The circuit uses a unique differential-to-peak detector circuit to generate a dynamic reference signal proportional to the input peak voltage. The input pulses are compared with the reference signal in an input network which operates in full differential mode with only a passive input filter. This reduces the introduction of circuit-induced noise, or jitter, generated in ground referenced input elements normally used in pulse conditioning circuits, especially speed transducer processing circuits. This circuit may be used for conditioning the sensor signal from the Fidler coil in a gas centrifuge for separation of isotopic gaseous mixtures.

  4. Pulse tube refrigerator; Parusukan reitoki

    Energy Technology Data Exchange (ETDEWEB)

    Hozumi, Yoshikazu [University of Tsukuba, Tsukuba (Japan); Shiraishi, Masao [Hiroshima University, Hiroshima (Japan)

    1999-06-05

    In the cryogenic field, high temperature superconductivity and research and development of the peripheral technology are popular. Refrigerating machine development of the very low temperature is also one of the results. Research and development are mainly advanced as a refrigerating machine of the center for the aerospace plane installation. There is special and small very low temperature refrigerating machine called 'the pulse tube refrigerating machine' of which the practical application is also recently being attempted for the semiconductor cooling using high temperature superconductivity. At present, the basic research of elucidation of refrigeration phenomenon of pulse tube refrigerating machine and development of high-performance pulse tube refrigerating machine is carried out by experiment in the Ministry of International Trade and Industry Mechanical Engineering Lab., Agency of Industrial Sci. and Technology and numerical simulation in Chiyoda Corp. In this report, the pulse tube refrigerating machine is introduced, and the application in the chemical engineering field is considered. (NEDO)

  5. Pulsed ultrasonic stir welding system

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    An ultrasonic stir welding system includes a welding head assembly having a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. During a welding operation, ultrasonic pulses are applied to the rod as it rotates about its longitudinal axis. The ultrasonic pulses are applied in such a way that they propagate parallel to the longitudinal axis of the rod.

  6. Optical pulses, lasers, measuring techniques

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology: Volume II: Optical Pulses - Lasers - Measuring Techniques focuses on the theoretical and engineering problems that result from the capacitor discharge technique.This book is organized into three main topics: light flash production from a capacitive energy storage; signal transmission and ranging systems by capacitor discharges and lasers; and impulse measuring technique. This text specifically discusses the air spark under atmospheric conditions, industrial equipment for laser flashing, and claims for light transmitting system. The application of light impulse sign

  7. Pulsed feedback defers cellular differentiation.

    Directory of Open Access Journals (Sweden)

    Joe H Levine

    2012-01-01

    Full Text Available Environmental signals induce diverse cellular differentiation programs. In certain systems, cells defer differentiation for extended time periods after the signal appears, proliferating through multiple rounds of cell division before committing to a new fate. How can cells set a deferral time much longer than the cell cycle? Here we study Bacillus subtilis cells that respond to sudden nutrient limitation with multiple rounds of growth and division before differentiating into spores. A well-characterized genetic circuit controls the concentration and phosphorylation of the master regulator Spo0A, which rises to a critical concentration to initiate sporulation. However, it remains unclear how this circuit enables cells to defer sporulation for multiple cell cycles. Using quantitative time-lapse fluorescence microscopy of Spo0A dynamics in individual cells, we observed pulses of Spo0A phosphorylation at a characteristic cell cycle phase. Pulse amplitudes grew systematically and cell-autonomously over multiple cell cycles leading up to sporulation. This pulse growth required a key positive feedback loop involving the sporulation kinases, without which the deferral of sporulation became ultrasensitive to kinase expression. Thus, deferral is controlled by a pulsed positive feedback loop in which kinase expression is activated by pulses of Spo0A phosphorylation. This pulsed positive feedback architecture provides a more robust mechanism for setting deferral times than constitutive kinase expression. Finally, using mathematical modeling, we show how pulsing and time delays together enable "polyphasic" positive feedback, in which different parts of a feedback loop are active at different times. Polyphasic feedback can enable more accurate tuning of long deferral times. Together, these results suggest that Bacillus subtilis uses a pulsed positive feedback loop to implement a "timer" that operates over timescales much longer than a cell cycle.

  8. Artistic Representation with Pulsed Holography

    Science.gov (United States)

    Ishii, S.

    2013-02-01

    This thesis describes artistic representation through pulsed holography. One of the prevalent practical problems in making holograms is object movement. Any movement of the object or film, including movement caused by acoustic vibration, has the same fatal results. One way of reducing the chance of movement is by ensuring that the exposure is very quick; using a pulsed laser can fulfill this objective. The attractiveness of using pulsed laser is based on the variety of materials or objects that can be recorded (e.g., liquid material or instantaneous scene of a moving object). One of the most interesting points about pulsed holograms is that some reconstructed images present us with completely different views of the real world. For example, the holographic image of liquid material does not appear fluid; it looks like a piece of hard glass that would produce a sharp sound upon tapping. In everyday life, we are unfamiliar with such an instantaneous scene. On the other hand, soft-textured materials such as a feather or wool differ from liquids when observed through holography. Using a pulsed hologram, we can sense the soft touch of the object or material with the help of realistic three-dimensional (3-D) images. The images allow us to realize the sense of touch in a way that resembles touching real objects. I had the opportunity to use a pulsed ruby laser soon after I started to work in the field of holography in 1979. Since then, I have made pulsed holograms of activities, including pouring water, breaking eggs, blowing soap bubbles, and scattering feathers and popcorn. I have also created holographic art with materials and objects, such as silk fiber, fabric, balloons, glass, flowers, and even the human body. Whenever I create art, I like to present the spectator with a new experience in perception. Therefore, I would like to introduce my experimental artwork through those pulsed holograms.

  9. High Voltage Pulse Testing Survey.

    Science.gov (United States)

    1985-10-01

    Cryogenic 23 E. Liquids 26 F. Solids 28 1. Polyethylene 28 2. Cross-Linked Polyethylene ( XLPE ) 29 3. Polyimide and Polyvenylchloride (PVC) 31 VI Benefits 35 A...Strength of XLPE Cables 29 vii * 4" I PROGRAM OBJECTIVES The Pulse Test Survey summarizes government, industry, and technical reports on high voltage pulse...system of silicone oil on a XLPE (cross-linked polyethylene) spacer tends to lower the impulse breakdown by approximately 10 percent. The negative impulse

  10. Millijoule pulse energy picosecond fiber chirped-pulse amplification system

    Institute of Scientific and Technical Information of China (English)

    Zhi Yang; Xiaohong Hu; Yishan Wang; Wei Zhang; Wei Zhao

    2011-01-01

    @@ The efficient generation of a 1.17-mJ laser pul8e with 360 ps duration using an ytterbium (Yb)-doped fiber amplifier chain seeded by a homemade mode-locked fiber laser is demonstrated experimentally.A specially designed figure-of-eight fiber laser acts as the seed source of a chirped-pulse amplification (CPA) system and generates mode-locked pulse8 with hundreds of picosecond widths.Two kinds of large-mode-area (LMA) double-clad Yb-doped fibers are employed to construct the pre-amplifier and main amplifier, All of the adopted instruments help avoid severe nonlinearity in fibers to raise sub-nanosecond pulse energy with acceptable signal-to-noise ratio (SNR).The output spectrum of this fiber-based CPA system shows that amplified spontaneous emission (ASE) is suppressed to better than 30 dB, and the onset of stimulated Raman scattering is excluded.%The efficient generation of a 1.17-mJ laser pulse with 360 ps duration using an ytterbium (Yb)-doped fiber amplifier chain seeded by a homemade mode-locked fiber laser is demonstrated experimentally. A specially designed figure-of-eight fiber laser acts as the seed source of a chirped-pulse amplification (CPA) system and generates mode-locked pulses with hundreds of picosecond widths. Two kinds of large-mode-area (LMA) double-clad Yb-doped fibers are employed to construct the pre-amplifier and main amplifier. All of the adopted instruments help avoid severe nonlinearity in fibers to raise sub-nanosecond pulse energy with acceptable signal-to-noise ratio (SNR). The output spectrum of this fiber-based CPA system shows that amplified spontaneous emission (ASE) is suppressed to better than 30 dB, and the onset of stimulated Raman scattering is excluded.

  11. Square pulse linear transformer driver

    Directory of Open Access Journals (Sweden)

    A. A. Kim

    2012-04-01

    Full Text Available The linear transformer driver (LTD technological approach can result in relatively compact devices that can deliver fast, high current, and high-voltage pulses straight out of the LTD cavity without any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The usual LTD architecture [A. A. Kim, M. G. Mazarakis, V. A. Sinebryukhov, B. M. Kovalchuk, V. A. Vizir, S. N Volkov, F. Bayol, A. N. Bastrikov, V. G. Durakov, S. V. Frolov, V. M. Alexeenko, D. H. McDaniel, W. E. Fowler, K. LeCheen, C. Olson, W. A. Stygar, K. W. Struve, J. Porter, and R. M. Gilgenbach, Phys. Rev. ST Accel. Beams 12, 050402 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050402; M. G. Mazarakis, W. E. Fowler, A. A. Kim, V. A. Sinebryukhov, S. T. Rogowski, R. A. Sharpe, D. H. McDaniel, C. L. Olson, J. L. Porter, K. W. Struve, W. A. Stygar, and J. R. Woodworth, Phys. Rev. ST Accel. Beams 12, 050401 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050401] provides sine shaped output pulses that may not be well suited for some applications like z-pinch drivers, flash radiography, high power microwaves, etc. A more suitable power pulse would have a flat or trapezoidal (rising or falling top. In this paper, we present the design and first test results of an LTD cavity that generates such a type of output pulse by including within its circular array a number of third harmonic bricks in addition to the main bricks. A voltage adder made out of a square pulse cavity linear array will produce the same shape output pulses provided that the timing of each cavity is synchronized with the propagation of the electromagnetic pulse.

  12. High-Altitude Electromagnetic Pulse (HEMP) Testing

    Science.gov (United States)

    2015-07-09

    Electromagnetic Pulse Horizontal Electromagnetic Pulse Advanced Fast Electromagnetic Pulse Nuclear Weapons Effect Testing and Environments 16. SECURITY...TOP 01-2-620A 9 July 2015 G-1 APPENDIX G. ABBREVIATIONS. AFEMP Advanced Fast Electromagnetic ... Electromagnetic Pulse A burst of electromagnetic radiation from a nuclear explosion or a suddenly fluctuating magnetic field. The resulting electric and

  13. Intense ultrashort terahertz pulses: generation and applications

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Matthias C [Max Planck Research Department for Structural Dynamics, University of Hamburg, CFEL, 22607 Hamburg (Germany); Fueloep, Jozsef Andras, E-mail: matthias.c.hoffmann@mpsd.cfel.de, E-mail: fulop@fizika.ttk.pte.hu [Department of Experimental Physics, University of Pecs, Ifjusag u. 6, 7624 Pecs (Hungary)

    2011-03-02

    Ultrashort terahertz pulses derived from femtosecond table-top sources have become a valuable tool for time-resolved spectroscopy during the last two decades. Until recently, the pulse energies and field strengths of these pulses have been generally too low to allow for the use as pump pulses or the study of nonlinear effects in the terahertz range. In this review article we will describe methods of generation of intense single cycle terahertz pulses with emphasis on optical rectification using the tilted-pulse-front pumping technique. We will also discuss some applications of these intense pulses in the emerging field of nonlinear terahertz spectroscopy. (topical review)

  14. Pulse compression and prepulse suppression apparatus

    Science.gov (United States)

    Dane, C.B.; Hackel, L.A.; George, E.V.; Miller, J.L.; Krupke, W.F.

    1993-11-09

    A pulse compression and prepulse suppression apparatus (10) for time compressing the output of a laser (14). A pump pulse (46) is separated from a seed pulse (48) by a first polarized beam splitter (20) according to the orientation of a half wave plate (18). The seed pulse (48) is directed into an SBS oscillator (44) by two plane mirrors (22, 26) and a corner mirror (24), the corner mirror (24) being movable to adjust timing. The pump pulse (46) is directed into an SBS amplifier 34 wherein SBS occurs. The seed pulse (48), having been propagated from the SBS oscillator (44), is then directed through the SBS amplifier (34) wherein it sweeps the energy of the pump pulse (46) out of the SBS amplifier (34) and is simultaneously compressed, and the time compressed pump pulse (46) is emitted as a pulse output (52). A second polarized beam splitter (38) directs any undepleted pump pulse 58 away from the SBS oscillator (44).

  15. Consecutive Bright Pulses in the Vela Pulsar

    CERN Document Server

    Palfreyman, Jim L; Dickey, John M; Young, Timothy G; Hotan, Claire E; 10.1088/2041-8205/735/1/L17

    2011-01-01

    We report on the discovery of consecutive bright radio pulses from the Vela pulsar, a new phenomenon that may lead to a greater understanding of the pulsar emission mechanism. This results from a total of 345 hr worth of observations of the Vela pulsar using the University of Tasmania's 26 m radio telescope to study the frequency and statistics of abnormally bright pulses and sub-pulses. The bright pulses show a tendency to appear consecutively. The observations found two groups of six consecutive bright pulses and many groups of two to five bright pulses in a row. The strong radio emission process that produces the six bright pulses lasts between 0.4 and 0.6 s. The numbers of bright pulses in sequence far exceed what would be expected if individual bright pulses were independent random events. Consecutive bright pulses must be generated by an emission process that is long lived relative to the rotation period of the neutron star.

  16. High-voltage, short-risetime pulse generator based on a ferrite pulse sharpener

    Energy Technology Data Exchange (ETDEWEB)

    Seddon, N.; Thornton, E.

    1988-11-01

    A high-voltage, short-risetime pulse generator is described. The generator consists of a Marx bank, which produces an initial high-voltage pulse, and a ferrite pulse sharpener that reduces the risetime of the pulse. The generator delivers 70-kV, 350-ps risetime pulses into a 50-..cap omega.. load.

  17. The coherent artifact in modern pulse measurements

    CERN Document Server

    Ratner, Justin; Wong, Tsz Chun; Bartels, Randy; Trebino, Rick

    2012-01-01

    We simulate multi-shot intensity-and-phase measurements of unstable ultrashort-pulse trains using frequency-resolved-optical-gating (FROG) and spectral phase interferometry for direct electric-field reconstruction (SPIDER). Both techniques fail to reveal the pulse structure. FROG yields the average pulse duration and suggests the instability by exhibiting disagreement between measured and retrieved traces. SPIDER under-estimates the average pulse duration but retrieves the correct average pulse spectral phase. An analytical calculation confirms this behavior.

  18. Wide Range SET Pulse Measurement

    Science.gov (United States)

    Shuler, Robert L.; Chen, Li

    2012-01-01

    A method for measuring a wide range of SET pulses is demonstrated. Use of dynamic logic, faster than ordinary CMOS, allows capture of short pulses. A weighted binning of SET lengths allows measurement of a wide range of pulse lengths with compact circuitry. A pulse-length-conservative pulse combiner tree routes SETs from combinational logic to the measurement circuit, allowing SET measurements in circuits that cannot easily be arranged in long chains. The method is applied to add-multiplex combinational logic, and to an array of NFET routing switches, at .35 micron. Pulses are captured in a chain of Domino Logic AND gates. Propagation through the chain is frozen on the trailing edge by dropping low the second "enable" input to the AND gates. Capacitive loading is increased in the latter stages to create an approximately logarithmic weighted binning, so that a broad range of pulse lengths can be captured with a 10 stage capture chain. Simulations show pulses can be captured which are 1/5th the length of those typically captured with leading edge triggered latch methods, and less than the length of those captured with a trailing edge latch method. After capture, the pulse pattern is transferred to an SEU protected shift register for readout. 64 instances of each of two types of logic are used as targets. One is a full adder with a 4 to 1 mux on its inputs. The other is a 4 x 4 NFET routing matrix. The outputs are passed through buffered XNOR comparators to identify pulses, which are merged in a buffered not-nand (OR) tree designed to avoid pulse absorption as much as possible. The output from each of the two test circuits are input into separate pulse measurement circuits. Test inputs were provided so that the circuit could be bench tested and calibrated. A third SET measurement circuit with no inputs was used to judge the contribution from direct hits on the measurement circuit. Heavy ions were used with an LET range from 12 to 176. At LET of 21 and below, the very

  19. The pulsing CPSD method for subcritical assemblies with pulsed sources

    CERN Document Server

    Ballester, D; Ballester, Daniel; Munoz-Cobo, Jose L.

    2005-01-01

    Stochastic neutron transport theory is applied to the derivation of the two-neutron-detectors cross power spectral density for subcritical assemblies when external pulsed sources are used. A general relationship between the two-detector probability generating functions of the kernel and the source is obtained considering the contribution to detectors statistics of both the pulsed source and the intrinsic neutron source. An expansion in alpha-eigenvalues is derived for the final solution, which permits to take into account the effect of higher harmonics in subcritical systems. Further, expressions corresponding to the fundamental mode approximation are compared with recent results from experiments performed under the MUSE-4 European research project.

  20. High field rf superconductivity: to pulse or not to pulse

    Energy Technology Data Exchange (ETDEWEB)

    Campisi, I.E.

    1984-10-01

    Experimental data on the behavior of superconductors under the application of rf fields of amplitude comparable to their critical fields are sporadic and not always consistent. In many cases the field level at which breakdown in superconducting rf cavities should be expected has not been clearly established. Tests conducted with very short (approx. 1 ..mu..s) rf pulses indicate that in this mode of operation fields close to the critical values can be consistently reached in superconducting cavities without breakdown. The advantages and disadvantages of the pulsed method are discussed compared to those of the more standard continuous wave (cw) systems. 60 references.

  1. Development of pulsed positron beam line with compact pulsing system

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Masaki, E-mail: maekawa.masaki@jaea.go.jp [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Kawasuso, Atsuo [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2012-01-01

    We have developed a pulsed slow positron beam with a pulse width of less than 200 ps and a period of 25 ns. The beam apparatus is composed of a Munich-type pre-buncher, a chopper and a buncher. Instead of the conventional RF cavity, a simple double-cylinder electrode is used for the buncher. The beam will be used for positron lifetime measurements. The time resolution of the whole system including lifetime measurement circuits is 250 ps, which is adequate for studying semiconductors and metals.

  2. Pre-earthquake magnetic pulses

    Directory of Open Access Journals (Sweden)

    J. Scoville

    2014-12-01

    Full Text Available A semiconductor model of rocks is shown to describe unipolar magnetic pulses, a phenomenon that has been observed prior to earthquakes. These pulses are generated deep in the Earth's crust, in and around the Hypocentral volume, days or even weeks before Earthquakes. They are observable at the surface because their extremely long wavelength allows them to pass through kilometers of rock. Interestingly, the source of these pulses may be triangulated to pinpoint locations where stresses are building deep within the crust. We couple a semiconductor drift-diffusion model to a magnetic field in order to describe the electromagnetic effects associated with electrical currents flowing within rocks. The resulting system of equations is solved numerically and it is seen that a volume of rock may act as a diode that produces transient currents when it switches bias. These unidirectional currents are expected to produce transient unipolar magnetic pulses similar in form, amplitude, and duration to those observed before earthquakes, and this suggests that the pulses could be the result of geophysical semiconductor processes.

  3. Pulsed discharge production Ar* metastables

    Science.gov (United States)

    Han, Jiande; Heaven, Michael C.; Emmons, Daniel; Perram, Glen P.; Weeks, David E.; Bailey, William F.

    2016-03-01

    The production of relatively high densities of Ar* metastables (>1012 cm-3) in Ar/He mixtures, at total pressures close to 1 atm, is essential for the efficient operation of an optically pumped Ar* laser. We have used emission spectroscopy and diode laser absorption spectroscopy measurements to observe the production and decay of Ar* in a parallel plate pulsed discharge. With discharge pulses of 1 μs duration we find that metastable production is dominated by processes occurring within the first 100 ns of the gas break-down. Application of multiple, closely spaced discharge pulses yields insights concerning conditions that favor metastable production. This information has been combined with time-resolved measurements of voltage and current. The experimental results and preliminary modeling of the discharge kinetics are presented.

  4. Zeptosecond $\\gamma$-ray pulses

    CERN Document Server

    Klaiber, Michael; Keitel, Christoph H

    2007-01-01

    High-order harmonic generation (HHG) in the relativistic regime is employed to obtain zeptosecond pulses of $\\gamma$-rays. The harmonics are generated from atomic systems in counterpropagating strong attosecond laser pulse trains of linear polarization. In this setup recollisions of the ionized electrons can be achieved in the highly relativistic regime via a reversal of the commonly deteriorating drift and without instability of the electron dynamics such as in a standing laser wave. As a result, coherent attosecond $\\gamma$-rays in the 10 MeV energy range as well as coherent zeptosecond $\\gamma$-ray pulses of MeV photon energy for time-resolved nuclear spectroscopy become feasible.

  5. Dynamic parabolic pulse generation using temporal shaping of wavelength to time mapped pulses.

    Science.gov (United States)

    Nguyen, Dat; Piracha, Mohammad Umar; Mandridis, Dimitrios; Delfyett, Peter J

    2011-06-20

    Self-phase modulation in fiber amplifiers can significantly degrade the quality of compressed pulses in chirped pulse amplification systems. Parabolic pulses with linear frequency chirp are suitable for suppressing nonlinearities, and to achieve high peak power pulses after compression. In this paper, we present an active time domain technique to generate parabolic pulses for chirped pulse amplification applications. Pulses from a mode-locked laser are temporally stretched and launched into an amplitude modulator, where the drive voltage is designed using the spectral shape of the input pulse and the transfer function of the modulator, resulting in the generation of parabolic pulses. Experimental results of pulse shaping with a pulse train from a mode-locked laser are presented, with a residual error of less than 5%. Moreover, an extinction ratio of 27 dB is achieved, which is ideal for chirped pulse amplification applications.

  6. Liquid micro pulsed plasma thruster

    Directory of Open Access Journals (Sweden)

    Szelecka Agnieszka

    2015-06-01

    Full Text Available A new type of pulsed plasma thruster (PPT for small satellite propulsion is investigated, of which the most innovative aspect is the use of a non-volatile liquid propellant. The thruster is based on an open capillary design. The thruster achieved a thrust-to-power ratio above 45 μN/W, which constitutes a 5-fold improvement over the water-propelled pulsed plasma thruster, and which is also slightly above the performance of a similarly sized PPT with a solid propellant.

  7. Pulse compressor with aberration correction

    Energy Technology Data Exchange (ETDEWEB)

    Mankos, Marian [Electron Optica, Inc., Palo Alto, CA (United States)

    2015-11-30

    In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded

  8. High-speed pulse techniques

    CERN Document Server

    Coekin, J A

    1975-01-01

    High-Speed Pulse Techniques covers the many aspects of technique in digital electronics and encompass some of the more fundamental factors that apply to all digital systems. The book describes the nature of pulse signals and their deliberate or inadvertent processing in networks, transmission lines and transformers, and then examines the characteristics and transient performance of semiconductor devices and integrated circuits. Some of the problems associated with the assembly of these into viable systems operating at ultra high speed are also looked at. The book examines the transients and w

  9. Neuromuscular disruption with ultrashort electrical pulses

    Science.gov (United States)

    Pakhomov, Andrei; Kolb, Juergen F.; Joshi, Ravindra P.; Schoenbach, Karl H.; Dayton, Thomas; Comeaux, James; Ashmore, John; Beason, Charles

    2006-05-01

    Experimental studies on single cells have shown that application of pulsed voltages, with submicrosecond pulse duration and an electric field on the order of 10 kV/cm, causes sudden alterations in the intracellular free calcium concentration, followed by immobilization of the cell. In order to examine electrical stimulation and incapacitation with such ultrashort pulses, experiments on anesthetized rats have been performed. The effect of single, 450 nanosecond monopolar pulses have been compared with that of single pulses with multi-microsecond duration (TASER pulses). Two conditions were explored: 1. the ability to elicit a muscle twitch, and, 2. the ability to suppress voluntary movement by using nanosecond pulses. The second condition is relevant for neuromuscular incapacitation. The preliminary results indicate that for stimulation microsecond pulses are advantageous over nanosecond pulses, whereas for incapacitation, the opposite seems to apply. The stimulation effects seem to scale with electrical charge, whereas the disruption effects don't follow a simple scaling law. The increase in intensity (time of incapacitation) for a given pulse duration, is increasing with electrical energy, but is more efficient for nanosecond than for microsecond pulses. This indicates different cellular mechanisms for incapacitation, most likely subcellular processes, which have been shown to become increasingly important when the pulse duration is shortened into the nanosecond range. If further studies can confirm these initial results, consequences of reduced pulse duration are a reduction in weight and volume of the pulse delivery system, and likely, because of the lower required energy for neuromuscular incapacitation, reduced safety risks.

  10. Control of high power pulse extracted from the maximally compressed pulse in a nonlinear optical fiber

    CERN Document Server

    Yang, Guangye; Jia, Suotang; Mihalache, Dumitru

    2013-01-01

    We address the possibility to control high power pulses extracted from the maximally compressed pulse in a nonlinear optical fiber by adjusting the initial excitation parameters. The numerical results show that the power, location and splitting order number of the maximally compressed pulse and the transmission features of high power pulses extracted from the maximally compressed pulse can be manipulated through adjusting the modulation amplitude, width, and phase of the initial Gaussian-type perturbation pulse on a continuous wave background.

  11. Pulse Delay and Speed-up of Ultra Fast Pulses in an Absorbing Quantum Well Medium

    DEFF Research Database (Denmark)

    Hansen, Per Lunnemann; Poel, Mike van der; Yvind, Kresten;

    2008-01-01

    Slow down and speed-up of 180 fs pulses in an absorbing semiconductor beyond the exisitng models is observed. Cascading gainand absorbing sections give us significant temporal pulse shifting at almost constant output pulse energy.......Slow down and speed-up of 180 fs pulses in an absorbing semiconductor beyond the exisitng models is observed. Cascading gainand absorbing sections give us significant temporal pulse shifting at almost constant output pulse energy....

  12. Dynamic Characterization of Fiber Optical Chirped Pulse Amplification for Sub-ps Pulses

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Rishøj, Lars Søgaard

    2013-01-01

    We investigate experimentally the propagation of sub-picosecond pulses in fiber optical parametric chirped pulse amplifiers, showing a significant broadening of the pulses from 450 fs up to 720 fs due to dispersion and self-phase modulation.......We investigate experimentally the propagation of sub-picosecond pulses in fiber optical parametric chirped pulse amplifiers, showing a significant broadening of the pulses from 450 fs up to 720 fs due to dispersion and self-phase modulation....

  13. 35 Volt, 180 Ampere Pulse Generator with Droop Control for Pulsing Xenon Arcs

    DEFF Research Database (Denmark)

    Hviid, T.; Nielsen, S. O.

    1972-01-01

    The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light.......The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light....

  14. Generation of pulsed ion beams by an inductive storage pulsed power generator

    Science.gov (United States)

    Katsuki, Sunao; Akiyama, Hidenori; Maeda, Sadao

    1990-10-01

    A pulsed power generator by an inductive energy storage system is extremely compact and light in comparison with a conventional pulsed power generator, which consists of a Marx bank and a water pulse forming line. A compact and light pulse power generator is applied to the generation of pulsed ion beams. A thin copper fuse is used an an opening switch, which is necessary in the inductive storage pulsed power generator. A magnetically insulated diode is used for the generation of ion beams. The pulsed ion beams are successfully generated by the inductive storage pulsed power generator for the first time.

  15. Radiation chemical effects in the near-field environment of a radwaste repository: {gamma} radiolysis in 6 molal NaCl solutions; Strahlenchemische Effekte im Endlagernahbereich: {gamma}-Radiolyse in 6 molarer NaCl-Loesung

    Energy Technology Data Exchange (ETDEWEB)

    Kelm, M.; Bohnert, E.

    1997-12-01

    The radiation emitted from high-level radioactive wastes in a radwaste repository causes radiolysis products to be formed in brines resulting from water intrusion. The products may alter via redox and complexing reactions the mobilisation processes of radionuclides. The major products of {gamma} radiolysis determined in 6 molal NaCl solution as a function of radiation dose are hydrogen, oxygen, and chlorate. Hypochlorite and chlorite were found to have concentrations in the {mu}Mol/kg range. There was no dependence on dose rate. For the experiments under atmospheric pressure, which allowed radiolytic gas to escape from the solution, the G values measured are 0.46 (H{sub 2}), 0.16 (O{sub 2}), and 0.074 (ClO{sub 3}). In pressurized experiments, with radiolytic gas remaining contained in the solution, the radiolytic effect was much smaller. After approx. 100 days, at a dose of about 2 MGy, gas equilibrium concentrations of some mMol/kg were measured. The results can be qualitatively described by a system of parallel running reaction rate equations. As to quantitative analysis, the reaction model needs to be refined. (orig./CB) [Deutsch] Die Strahlung von hochradioaktiven Abfaellen in einem Endlager im Salz hat zur Folge, dass bei einem Wasserzutritt in den entstehenden Laugen Radiolyseprodukte gebildet werden. Die Radiolyseprodukte koennen durch Redox- und Komplexierungsreaktionen die Mobilisierbarkeit von Radionukliden veraendern. Als Hauptprodukte der {gamma}-Radiolyse wurden in 6 molaler NaCl-Loesung Wasserstoff, Sauerstoff und Chlorat in Abhaengigkeit von der Dosis bestimmt. Hypochlorit und Chlorit erreichten nur Konzentrationen im {mu}Mol/kg-Bereich. Eine Dosisleistungsabhaengigkeit war nicht festzustellen. Bei den Experimenten unter Normaldruck, bei denen die Radiolysegase aus der Loesung entweichen konnten, betrugen die G-Werte 0.46 (H{sub 2}), 0,16 (O{sub 2}) und 0,074 (ClO{sub 3}{sup -}). Bei den Experimenten unter Druck wurden die Radiolysegase in Loesung

  16. Cylindrically Polarized Nondiffracting Optical Pulses

    CERN Document Server

    Ornigotti, Marco; Szameit, Alexander

    2016-01-01

    We extend the concept of radially and azimuthally polarized optical beams to the polychromatic domain by introducing cylindrically polarized nondiffracting optical pulses. In particular, we discuss in detail the case of cylindrically polarized X-waves, both in the paraxial and nonparaxial regime. The explicit expressions for the electric and magnetic fields of cylindrically polarized X-waves is also reported.

  17. Nonparametric estimation of ultrasound pulses

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Leeman, Sidney

    1994-01-01

    An algorithm for nonparametric estimation of 1D ultrasound pulses in echo sequences from human tissues is derived. The technique is a variation of the homomorphic filtering technique using the real cepstrum, and the underlying basis of the method is explained. The algorithm exploits a priori...

  18. Wave equations for pulse propagation

    Science.gov (United States)

    Shore, B. W.

    1987-06-01

    Theoretical discussions of the propagation of pulses of laser radiation through atomic or molecular vapor rely on a number of traditional approximations for idealizing the radiation and the molecules, and for quantifying their mutual interaction by various equations of propagation (for the radiation) and excitation (for the molecules). In treating short-pulse phenomena it is essential to consider coherent excitation phenomena of the sort that is manifest in Rabi oscillations of atomic or molecular populations. Such processes are not adequately treated by rate equations for excitation nor by rate equations for radiation. As part of a more comprehensive treatment of the coupled equations that describe propagation of short pulses, this memo presents background discussion of the equations that describe the field. This memo discusses the origin, in Maxwell's equations, of the wave equation used in the description of pulse propagation. It notes the separation into lamellar and solenoidal (or longitudinal and transverse) and positive and negative frequency parts. It mentions the possibility of separating the polarization field into linear and nonlinear parts, in order to define a susceptibility or index of refraction and, from these, a phase and group velocity.

  19. All about Heart Rate (Pulse)

    Science.gov (United States)

    ... get a picture of your health. Learn more: Blood Pressure Vs. Heart Rate Target Heart Rate Arrhythmias (abnormal heart rhythms) This ... Healthy 6 What are the Symptoms of High Blood Pressure? 7 All About Heart Rate (Pulse) 8 Warning Signs of a Heart Attack ...

  20. Atomic collisions involving pulsed positrons

    DEFF Research Database (Denmark)

    Merrison, J. P.; Bluhme, H.; Field, D.

    2000-01-01

    Conventional slow positron beams have been widely and profitably used to study atomic collisions and have been instrumental in understanding the dynamics of ionization. The next generation of positron atomic collision studies are possible with the use of charged particle traps. Not only can large...... of accelerators for producing intense positron pulses will be discussed in the context of atomic physics experiments....

  1. Ptychographic reconstruction of attosecond pulses

    CERN Document Server

    Lucchini, M; Ludwig, A; Gallmann, L; Keller, U; Feurer, T

    2015-01-01

    We demonstrate a new attosecond pulse reconstruction modality which uses an algorithm that is derived from ptychography. In contrast to other methods, energy and delay sampling are not correlated, and as a result, the number of electron spectra to record is considerably smaller. Together with the robust algorithm, this leads to a more precise and fast convergence of the reconstruction.

  2. CSR Pulsed Switching Power Supplies

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In 2001, CSR power supply system made a great progress. Three prototypes were designed for CSR quadruple and correct magnet. Three different companies provided the three prototypes, but the same circuit-chopper were employed. The simplified diagram is showed in Fig.1. All pulsed switching power supply prototypes were tested successfully before the end of 2001.

  3. Temporal resolution beyond the average pulse duration in shaped noisy-pulse transient absorption spectroscopy.

    Science.gov (United States)

    Meyer, Kristina; Müller, Niklas; Liu, Zuoye; Pfeifer, Thomas

    2016-12-20

    In time-resolved spectroscopy, it is a widespread belief that the temporal resolution is determined by the laser pulse duration. Recently, it was observed and shown that partially coherent laser pulses as they are provided by free-electron-laser (FEL) sources offer an alternative route to reach a temporal resolution below the average pulse duration. Here, we demonstrate the generation of partially coherent light in the laboratory like we observe it at FELs. We present the successful implementation of such statistically fluctuating pulses by using the pulse-shaping technique. These pulses exhibit an average pulse duration about 10 times larger than their bandwidth limit. The shaped pulses are then applied to transient-absorption measurements in the dye IR144. Despite the noisy characteristics of the laser pulses, features in the measured absorption spectra occurring on time scales much faster than the average pulse duration are resolved, thus proving the universality of the described noisy-pulse concept.

  4. Cryosurgery with pulsed electric fields.

    Science.gov (United States)

    Daniels, Charlotte S; Rubinsky, Boris

    2011-01-01

    This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF) are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF) was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused PEFs could be used to

  5. Cryosurgery with pulsed electric fields.

    Directory of Open Access Journals (Sweden)

    Charlotte S Daniels

    Full Text Available This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused

  6. Cryosurgery with Pulsed Electric Fields

    Science.gov (United States)

    Daniels, Charlotte S.; Rubinsky, Boris

    2011-01-01

    This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF) are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF) was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused PEFs could be used to

  7. Wave equations for pulse propagation

    Energy Technology Data Exchange (ETDEWEB)

    Shore, B.W.

    1987-06-24

    Theoretical discussions of the propagation of pulses of laser radiation through atomic or molecular vapor rely on a number of traditional approximations for idealizing the radiation and the molecules, and for quantifying their mutual interaction by various equations of propagation (for the radiation) and excitation (for the molecules). In treating short-pulse phenomena it is essential to consider coherent excitation phenomena of the sort that is manifest in Rabi oscillations of atomic or molecular populations. Such processes are not adequately treated by rate equations for excitation nor by rate equations for radiation. As part of a more comprehensive treatment of the coupled equations that describe propagation of short pulses, this memo presents background discussion of the equations that describe the field. This memo discusses the origin, in Maxwell's equations, of the wave equation used in the description of pulse propagation. It notes the separation into lamellar and solenoidal (or longitudinal and transverse) and positive and negative frequency parts. It mentions the possibility of separating the polarization field into linear and nonlinear parts, in order to define a susceptibility or index of refraction and, from these, a phase and group velocity. The memo discusses various ways of characterizing the polarization characteristics of plane waves, that is, of parameterizing a transverse unit vector, such as the Jones vector, the Stokes vector, and the Poincare sphere. It discusses the connection between macroscopically defined quantities, such as the intensity or, more generally, the Stokes parameters, and microscopic field amplitudes. The material presented here is a portion of a more extensive treatment of propagation to be presented separately. The equations presented here have been described in various books and articles. They are collected here as a summary and review of theory needed when treating pulse propagation.

  8. Pulse frequency classification based on BP neural network

    Institute of Scientific and Technical Information of China (English)

    WANG Rui; WANG Xu; YANG Dan; FU Rong

    2006-01-01

    In Traditional Chinese Medicine (TCM), it is an important parameter of the clinic disease diagnosis to analysis the pulse frequency. This article accords to pulse eight major essentials to identify pulse type of the pulse frequency classification based on back-propagation neural networks (BPNN). The pulse frequency classification includes slow pulse, moderate pulse, rapid pulse etc. By feature parameter of the pulse frequency analysis research and establish to identify system of pulse frequency features. The pulse signal from detecting system extracts period, frequency etc feature parameter to compare with standard feature value of pulse type. The result shows that identify-rate attains 92.5% above.

  9. Developing classification indices for Chinese pulse diagnosis

    CERN Document Server

    Shu, Jian-Jun

    2014-01-01

    Aim: To develop classification criteria for Chinese pulse diagnosis and to objectify the ancient diagnostic technique. Methods: Chinese pulse curves are treated as wave signals. Multidimensional variable analysis is performed to provide the best curve fit between the recorded Chinese pulse waveforms and the collective Gamma density functions. Results: Chinese pulses can be recognized quantitatively by the newly-developed four classification indices, that is, the wave length, the relative phase difference, the rate parameter, and the peak ratio. The new quantitative classification not only reduces the dependency of pulse diagnosis on Chinese physician's experience, but also is able to interpret pathological wrist-pulse waveforms more precisely. Conclusions: Traditionally, Chinese physicians use fingertips to feel the wrist-pulses of patients in order to determine their health conditions. The qualitative theory of the Chinese pulse diagnosis is based on the experience of Chinese physicians for thousands of year...

  10. Dispersion compensation in chirped pulse amplification systems

    Science.gov (United States)

    Bayramian, Andrew James; Molander, William A.

    2014-07-15

    A chirped pulse amplification system includes a laser source providing an input laser pulse along an optical path. The input laser pulse is characterized by a first temporal duration. The system also includes a multi-pass pulse stretcher disposed along the optical path. The multi-pass pulse stretcher includes a first set of mirrors operable to receive input light in a first plane and output light in a second plane parallel to the first plane and a first diffraction grating. The pulse stretcher also includes a second set of mirrors operable to receive light diffracted from the first diffraction grating and a second diffraction grating. The pulse stretcher further includes a reflective element operable to reflect light diffracted from the second diffraction grating. The system further includes an amplifier, a pulse compressor, and a passive dispersion compensator disposed along the optical path.

  11. Linear transformer driver for pulse generation

    Science.gov (United States)

    Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A

    2015-04-07

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.

  12. Exact Solutions to Short Pulse Equation

    Institute of Scientific and Technical Information of China (English)

    FU Zun-Tao; ZHENG Ming-Hua; LIU Shi-Kuo

    2009-01-01

    In this paper, dependent and independent variable transformations are introduced to solve the short pulse equation. It is shown that different kinds of solutions can be obtained to the short pulse equation.

  13. Digital Communication Using Chaotic Pulse Generators

    CERN Document Server

    Rulkov, N F; Tsimring, L S; Volkovskii, A R; Abarbanel, Henry D I; Larson, L; Yao, K

    1999-01-01

    Utilization of chaotic signals for covert communications remains a very promising practical application. Multiple studies indicated that the major shortcoming of recently proposed chaos-based communication schemes is their susceptibility to noise and distortions in communication channels. In this talk we discuss a new approach to communication with chaotic signals, which demonstrates good performance in the presence of channel distortions. This communication scheme is based upon chaotic signals in the form of pulse trains where intervals between the pulses are determined by chaotic dynamics of a pulse generator. The pulse train with chaotic interpulse intervals is used as a carrier. Binary information is modulated onto this carrier by the pulse position modulation method, such that each pulse is either left unchanged or delayed by a certain time, depending on whether ``0'' or ``1'' is transmitted. By synchronizing the receiver to the chaotic pulse train we can anticipate the timing of pulses corresponding to ...

  14. Linear transformer driver for pulse generation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Alexander A; Mazarakis, Michael G; Sinebryukhov, Vadim A; Volkov, Sergey N; Kondratiev, Sergey S; Alexeenko, Vitaly M; Bayol, Frederic; Demol, Gauthier; Stygar, William A

    2015-04-07

    A linear transformer driver includes at least one ferrite ring positioned to accept a load. The linear transformer driver also includes a first power delivery module that includes a first charge storage devices and a first switch. The first power delivery module sends a first energy in the form of a first pulse to the load. The linear transformer driver also includes a second power delivery module including a second charge storage device and a second switch. The second power delivery module sends a second energy in the form of a second pulse to the load. The second pulse has a frequency that is approximately three times the frequency of the first pulse. The at least one ferrite ring is positioned to force the first pulse and the second pulse to the load by temporarily isolating the first pulse and the second pulse from an electrical ground.

  15. Treatment Pulse Application for Magnetic Stimulation

    Directory of Open Access Journals (Sweden)

    Sun-Seob Choi

    2011-01-01

    Full Text Available Treatment and diagnosis can be made in difficult areas simply by changing the output pulse form of the magnetic stimulation device. However, there is a limitation in the range of treatments and diagnoses of a conventional sinusoidal stimulation treatment pulse because the intensity, width, and form of the pulse must be changed according to the lesion type. This paper reports a multidischarge method, where the stimulation coils were driven in sequence via multiple switching control. The limitation of the existing simple sinusoidal pulse form could be overcome by changing the intensity, width, and form of the pulse. In this study, a new sequential discharge method was proposed to freely alter the pulse width. The output characteristics of the stimulation treatment pulse were examined according to the trigger signal delay applied to the switch at each stage by applying a range of superposition pulses to the magnetic simulation device, which is widely used in industry and medicine.

  16. Exawatt-Zettawatt Pulse Generation and Applications

    OpenAIRE

    Mourou, G. A.; Fisch, N. J.; Malkin, V. M.; Toroker, Z.; Khazanov, E. A.; Sergeev, A. M.; TAJIMA, T.

    2011-01-01

    A new amplification method, weaving the three basic compression techniques, Chirped Pulse Amplification (CPA), Optical Parametric Chirped Pulse Amplification (OPCPA) and Plasma Compression by Backward Raman Amplification (BRA) in plasma, is proposed. It is called C3 for Cascaded Conversion Compression. It has the capability to compress with good efficiency kilojoule to megajoule, nanosecond laser pulses into femtosecond pulses, to produce exawatt and beyond peak power. In the future, C3 could...

  17. High Power Picosecond Laser Pulse Recirculation

    Energy Technology Data Exchange (ETDEWEB)

    Shverdin, M Y; Jovanovic, I; Semenov, V A; Betts, S M; Brown, C; Gibson, D J; Shuttlesworth, R M; Hartemann, F V; Siders, C W; Barty, C P

    2010-04-12

    We demonstrate a nonlinear crystal-based short pulse recirculation cavity for trapping the second harmonic of an incident high power laser pulse. This scheme aims to increase the efficiency and flux of Compton-scattering based light sources. We demonstrate up to 36x average power enhancement of frequency doubled sub-millijoule picosecond pulses, and 17x average power enhancement of 177 mJ, 10 ps, 10 Hz pulses.

  18. High-power picosecond laser pulse recirculation.

    Science.gov (United States)

    Shverdin, M Y; Jovanovic, I; Semenov, V A; Betts, S M; Brown, C; Gibson, D J; Shuttlesworth, R M; Hartemann, F V; Siders, C W; Barty, C P J

    2010-07-01

    We demonstrate a nonlinear crystal-based short pulse recirculation cavity for trapping the second harmonic of an incident high-power laser pulse. This scheme aims to increase the efficiency and flux of Compton-scattering-based light sources. We demonstrate up to 40x average power enhancement of frequency-doubled submillijoule picosecond pulses, and 17x average power enhancement of 177 mJ, 10 ps, 10 Hz pulses.

  19. Nonlinear optics with stationary pulses of light

    OpenAIRE

    Andre, A.; Bajcsy, M.; Zibrov, A. S.; Lukin, M. D.

    2004-01-01

    We show that the recently demonstrated technique for generating stationary pulses of light [Nature {\\bf 426}, 638 (2003)] can be extended to localize optical pulses in all three spatial dimensions in a resonant atomic medium. This method can be used to dramatically enhance the nonlinear interaction between weak optical pulses. In particular, we show that an efficient Kerr-like interaction between two pulses can be implemented as a sequence of several purely linear optical processes. The resul...

  20. Chirped Pulse Microwave Spectroscopy in Pulsed Uniform Supersonic Flows

    Science.gov (United States)

    Abeysekera, Chamara; Oldham, James; Prozument, Kirill; Joalland, Baptiste; Park, Barratt; Field, Robert W.; Sims, Ian; Suits, Arthur; Zack, Lindsay

    2014-06-01

    We present preliminary results describing the development of a new instrument that combines two powerful techniques: Chirped Pulse-Fourier Transform MicroWave (CP-FTMW) spectroscopy and pulsed uniform supersonic flows. It promises a nearly universal detection method that can deliver quantitative isomer, conformer, and vibrational level specific detection, characterization of unstable reaction products and intermediates and perform unique spectroscopic, kinetics and dynamics measurements. We have constructed a new high-power K_a-band, 26-40 GHz, chirped pulse spectrometer with sub-MHz resolution, analogous to the revolutionary CP-FTMW spectroscopic technique developed in the Pate group at University of Virginia. In order to study smaller molecules, the E-band, 60-90 GHz, CP capability was added to our spectrometer. A novel strategy for generating uniform supersonic flow through a Laval nozzle is introduced. High throughput pulsed piezo-valve is used to produce cold (30 K) uniform flow with large volumes of 150 cm^3 and densities of 1014 molecules/cm3 with modest pumping facilities. The uniform flow conditions for a variety of noble gases extend as far as 20 cm from the Laval nozzle and a single compound turbo-molecular pump maintains the operating pressure. Two competing design considerations are critical to the performance of the system: a low temperature flow is needed to maximize the population difference between rotational levels, and high gas number densities are needed to ensure rapid cooling to achieve the uniform flow conditions. At the same time, collision times shorter than the chirp duration will give inaccurate intensities and reduced signal levels due to collisional dephasing of free induction decay. Details of the instrument and future directions and challenges will be discussed.

  1. Third Harmonic Imaging using a Pulse Inversion

    DEFF Research Database (Denmark)

    Rasmussen, Joachim; Du, Yigang; Jensen, Jørgen Arendt

    2011-01-01

    The pulse inversion (PI) technique can be utilized to separate and enhance harmonic components of a waveform for tissue harmonic imaging. While most ultrasound systems can perform pulse inversion, only few image the 3rd harmonic component. PI pulse subtraction can isolate and enhance the 3rd...

  2. Pulse crop diseases in the Pacific Northwest

    Science.gov (United States)

    The United Nations declared that 2016 is the International Year of Pulses (IYP). This UN declaration of IYP will certainly increase awareness of pulses and likely position pulses as a primary source of protein and other essential nutrients for human diets. The US Pacific Northwest region (Idaho, Or...

  3. REFLECTANCE PULSE OXIMETRY IN FETAL LAMBS

    NARCIS (Netherlands)

    DASSEL, AC; GRAAFF, R; AARNOUDSE, JG; ELSTRODT, JM; HEIDA, P; KOELINK, MH; DEMUL, FF; GREVE, J

    1992-01-01

    Transmission pulse oximetry is used for monitoring in many clinical settings. However, for fetal monitoring during labor and in situations with poor peripheral perfusion, transmission pulse oximetry cannot be used. Therefore, we developed a reflectance pulse oximeter, which uses the relative intensi

  4. Hg-Arc Lamp, Pulse Excitation.

    Science.gov (United States)

    1986-09-01

    References 1. "Pulsed Mercury Capillary Lamps .,"P. Dal Pozzo, R. Polloni, and 0. Svelto , J. Appi. Phys. 6, 342 (1975). * 2. "Pulsed High-Pressure Mercury...Capillary Lamps .. ,P. Dal Pozzo, R. Polloni, * and 0. Svelto , J. Appi. Phys. 6, 381 (1975). 3. "Characteristics of the Radiation Pulses of Very-High

  5. A self-consistent Maltsev pulse model

    Science.gov (United States)

    Buneman, O.

    1985-04-01

    A self-consistent model for an electron pulse propagating through a plasma is presented. In this model, the charge imbalance between plasma ions, plasma electrons and pulse electrons creates the travelling potential well in which the pulse electrons are trapped.

  6. High speed, high current pulsed driver circuit

    Energy Technology Data Exchange (ETDEWEB)

    Carlen, Christopher R.

    2017-03-21

    Various technologies presented herein relate to driving a LED such that the LED emits short duration pulses of light. This is accomplished by driving the LED with short duration, high amplitude current pulses. When the LED is driven by short duration, high amplitude current pulses, the LED emits light at a greater amplitude compared to when the LED is driven by continuous wave current.

  7. Nonspreading Light Pulses in Photonic Crystals

    OpenAIRE

    Staliunas, K.; Serrat, C.; Herrero, R; Cojocaru, C.; Trull, J.

    2005-01-01

    We investigate propagation of light pulses in photonic crystals in the vicinity of the zero-diffraction point. We show that Gaussian pulses due to nonzero width of their spectrum spread weakly in space and time during the propagation. We also find the family of nonspreading pulses, propagating invariantly in the vicinity of the zero diffraction point of photonic crystals.

  8. Double pulse Thomson scattering system at RTP

    NARCIS (Netherlands)

    Beurskens, M. N. A.; Barth, C. J.; Chu, C.C.; Donne, A. J. H.; Herranz, J. A.; Cardozo, N. J. L.; van der Meiden, H. J.; Pijper, F.J.

    1997-01-01

    In this article a double pulse multiposition Thomson scattering diagnostic, under construction at RTP, is discussed. Light from a double pulsed ruby laser (pulse separation: 10-800 mu s, max. 2x12.5 J) is scattered by the free electrons of the tokamak plasma and relayed to a Littrow polychromator fo

  9. <3> OMEGA pulse-forming network

    CERN Multimedia

    1974-01-01

    Adjustement of the 3 W pulse-forming network of the SPS beam dumping system. When charged at 60 kV, this PFN gives 10 kA, 25 ms current pulses, with oscillations, superimposed on the pulse flat top, of an amplitude of +/- 1 Ka.

  10. Perceptions of European stakeholders of pulse fishing

    NARCIS (Netherlands)

    Kraan, M.L.; Trapman, B.K.; Rasenberg, M.M.M.

    2015-01-01

    This research project examines the concerns and questions of European stakeholders about pulse fishing, in order to assess to what extent the knowledge agenda on pulse fishing covers these issues. To get a first impression of the concerns about pulse fishing, and to get an idea of the stakeholders t

  11. A Study of New Pulse Auscultation System

    Directory of Open Access Journals (Sweden)

    Ying-Yun Chen

    2015-04-01

    Full Text Available This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine’s pulsing techniques, where pulse signals at places called “cun”, “guan” and “chi” of the left hand were measured during lifting (100 g, searching (125 g and pressing (150 g actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners’ objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision.

  12. Combined effects of Fe(II) and oxidizing radiolysis products on UO2 and PuO2 dissolution in a system containing solid UO2 and PuO2

    Science.gov (United States)

    Amme, Marcus; Pehrman, Reijo; Deutsch, Rudolf; Roth, Olivia; Jonsson, Mats

    2012-11-01

    The stability of UO2 spent nuclear fuel in an oxygen-free geological repository depends on the absence of oxidizing reaction partners in the near field. This work investigates the reactions between the products of water radiolysis by alpha radiation and Fe(II) an the effect on UO2 dissolution. Solid 238PuO2 powder and UO2 pellet were allowed to react in Fe(II) solution in oxygen-free batch reactor tests and kinetics of the subsequent redox reactions were measured. Depending on the concentration of Fe(II) (tests with 10-5 and 10-4 mol L-1 were made), the induced redox reactions took place between 20 and 400 h. Dissolved uranium concentrations went first through a minimum caused by reduction, followed by a maximum caused by radiolytic oxidation, and eventually reached another minimum, probably due to sorption on precipitated Fe(III). Plutonium concentrations were decreasing steadily after going through a maximum about 70 h from the start of the experiments. The results show that in the presence of the strong alpha-radiolytic field induced by the presence of solid 238Pu, the behavior of the system is largely governed by Fe(II) as it controls the H2O2 concentration, reduces U(VI) in solution and drives the Fenton reaction leading to the oxidation of Pu(IV).

  13. A Monte-Carlo step-by-step simulation code of the non-homogeneous chemistry of the radiolysis of water and aqueous solutions. Part I: theoretical framework and implementation.

    Science.gov (United States)

    Plante, Ianik

    2011-08-01

    The importance of the radiolysis of water in irradiation of biological systems has motivated considerable theoretical and experimental work in the radiation chemistry of water and aqueous solutions. In particular, Monte-Carlo simulations of radiation track structure and non-homogeneous chemistry have greatly contributed to the understanding of experimental results in radiation chemistry of heavy ions. Actually, most simulations of the non-homogeneous chemistry are done using the Independent Reaction Time (IRT) method, a very fast technique. The main limitation of the IRT method is that the positions of the radiolytic species are not calculated as a function of time, which is needed to simulate the irradiation of more complex systems. Step-by-step (SBS) methods, which are able to provide such information, have been used only sparsely because these are time consuming in terms of calculation. Recent improvements in computer performance now allow the regular use of the SBS method in radiation chemistry. In the present paper, the first of a series of two, the SBS method is reviewed in detail. To these ends, simulation of diffusion of particles and chemical reactions in aqueous solutions is reviewed, and implementation of the program is discussed. Simulation of model systems is then performed to validate the adequacy of stepwise diffusion and reaction schemes. In the second paper, radiochemical yields of simulated radiation tracks calculated by the SBS program in different conditions of LET, pH, and temperature are compared with results from the IRT program and experimental data.

  14. Study of water radiolysis in relation with the primary cooling circuit of pressurized water reactors; Etude sur la radiolyse de l`eau en relation avec le circuit primaire de refroidissement des reacteurs nucleaires a eau sous pression

    Energy Technology Data Exchange (ETDEWEB)

    Pastina, B

    1997-07-01

    This memorandum shows a fundamental study on the water radiolysis in relation with the cooling primary circuit of PWR type reactors. The water of the primary circuit contains boric acid a soluble neutronic poison and also hydrogen that has for role to inhibit the water decomposition under radiation effect. In the aim to better understand the mechanism of dissolved hydrogen action and to evaluate the impact of several parameters on this mechanism, aqueous solutions with boric acid and hydrogen have been irradiated in a experimental nuclear reactor, at 30, 100 and 200 Celsius degrees. It has been found that, with hydrogen, the water decomposition under irradiation is a threshold phenomenon in function of the ratio between the radiation flux `1` B(n, )`7 Li and the gamma flux. When this ratio become too high, the number of radicals is not sufficient to participate at the chain reaction, and then water is decomposed in O{sub 2} and H{sub 2}O{sub 2} in a irreversible way. The temperature has a beneficial part on this mechanism. The iron ion and the copper ion favour the water decomposition. (N.C.). 83 refs.

  15. Isolated sub-10 attosecond pulse generation by a 6-fs driving pulse and a 5-fs subharmonic controlling pulse

    Directory of Open Access Journals (Sweden)

    Yunhui Wang

    2012-06-01

    Full Text Available We theoretically study high-order harmonic generation by quantum path control in a special two-color laser field, which is synthesized by a 6 fs/800 nm fundamental pulse and a weaker 5 fs/1600 nm subharmonic controlling pulse. Single quantum path is selected without optimizing any carrier phase, which not only broadens the harmonic bandwidth to 400 eV, but also enhances the harmonic conversion efficiency in comparison with the short-plus-long scheme, which is based on 5 fs/800 nm driving pulse and 6 fs/1600 nm control pulse. An isolated 8-attosecond pulse is produced with currently available ultrafast laser sources.

  16. Generation of few-cycle terawatt light pulses using optical parametric chirped pulse amplification

    NARCIS (Netherlands)

    Witte, S.; Zinkstok, R.T.; Hogervorst, W.; Eikema, K.S.E.

    2005-01-01

    We demonstrate the generation of 9.8 +/- 0.3 fs laser pulses with a peak power exceeding one terawatt at 30 Hz repetition rate, using optical parametric chirped pulse amplification. The amplifier is pumped by 140 mJ, 60 ps pulses at 532 nm, and amplifies seed pulses from a Ti: Sapphire oscillator to

  17. A Method for Distinguishing Attosecond Single Pulse from Attosecond Pulse Train

    Institute of Scientific and Technical Information of China (English)

    HUO Yi-Ping; ZENG Zhi-Nan; LI Ru-Xin; XU Zhi-Zhan

    2004-01-01

    @@ The driving laser field assisted attosecond soft-extreme-ultraviolet (XUV) photo-ionization was used successfully to measure the duration of the attosecond pulse based on the cross-correlation method. However, this method in principle cannot distinguish a single attosecond pulse from the attosecond pulse train. We propose a technique for directly distinguishing attosecond single pulse from attosecond pulse train based on the photo-ionization of atoms by attosecond XUV pulse in the presence of a two-colour strong laser pulse.

  18. CW seeded optical parametric amplifier providing wavelength and pulse duration tunable nearly transform limited pulses.

    Science.gov (United States)

    Hädrich, S; Gottschall, T; Rothhardt, J; Limpert, J; Tünnermann, A

    2010-02-01

    An optical parametric amplifier that delivers nearly transform limited pulses is presented. The center wavelength of these pulses can be tuned between 993 nm and 1070 nm and, at the same time, the pulse duration is varied between 206 fs and 650 fs. At the shortest pulse duration the pulse energy was increased up to 7.2 microJ at 50 kHz repetition rate. Variation of the wavelength is achieved by applying a tunable cw seed while the pulse duration can be varied via altering the pump pulse duration. This scheme offers superior flexibility and scaling possibilities.

  19. Unsplit bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2011-05-24

    A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  20. Pulsed Power Driven Fusion Energy

    Energy Technology Data Exchange (ETDEWEB)

    SLUTZ,STEPHEN A.

    1999-11-22

    Pulsed power is a robust and inexpensive technology for obtaining high powers. Considerable progress has been made on developing light ion beams as a means of transporting this power to inertial fusion capsules. However, further progress is hampered by the lack of an adequate ion source. Alternatively, z-pinches can efficiently convert pulsed power into thermal radiation, which can be used to drive an inertial fusion capsule. However, a z-pinch driven fusion explosion will destroy a portion of the transmission line that delivers the electrical power to the z-pinch. They investigate several options for providing standoff for z-pinch driven fusion. Recyclable Transmission Lines (RTLs) appear to be the most promising approach.

  1. Acoustic emission linear pulse holography

    Science.gov (United States)

    Collins, H.D.; Busse, L.J.; Lemon, D.K.

    1983-10-25

    This device relates to the concept of and means for performing Acoustic Emission Linear Pulse Holography, which combines the advantages of linear holographic imaging and Acoustic Emission into a single non-destructive inspection system. This unique system produces a chronological, linear holographic image of a flaw by utilizing the acoustic energy emitted during crack growth. The innovation is the concept of utilizing the crack-generated acoustic emission energy to generate a chronological series of images of a growing crack by applying linear, pulse holographic processing to the acoustic emission data. The process is implemented by placing on a structure an array of piezoelectric sensors (typically 16 or 32 of them) near the defect location. A reference sensor is placed between the defect and the array.

  2. Pulsed DEMO design assessment studies

    CERN Document Server

    Todd, T N

    2013-01-01

    Now that ITER is under construction, interest is increasing in the specification and design of the successor machine, a Demonstration Power Plant (DEMO), which in Europe is coordinated by the EFDA Power Plant Physics and Technology programme. This paper summarises the work carried out for EFDA in 2011-2012 on design issues pertinent to a pulsed version of DEMO, intended to be implemented with little or no extrapolation of technology available today. The work was carried out by the Euratom Fusion Associations CCFE, CEA, CRPP, ENEA and KIT, and in addition to a review of recent relevant literature addressed systems code analyses (pulse length vs. size), erosion of plasma facing components, thermomechanical fatigue in the blanket and first wall, a range of energy storage issues, and fatigue life improvements in Nb3Sn CICC superconductors.

  3. Optimal filter bandwidth for pulse oximetry

    Science.gov (United States)

    Stuban, Norbert; Niwayama, Masatsugu

    2012-10-01

    Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.

  4. Pulse amplitude modulated chlorophyll fluorometer

    Energy Technology Data Exchange (ETDEWEB)

    Greenbaum, Elias; Wu, Jie

    2015-12-29

    Chlorophyll fluorometry may be used for detecting toxins in a sample because of changes in micro algae. A portable lab on a chip ("LOAC") based chlorophyll fluorometer may be used for toxin detection and environmental monitoring. In particular, the system may include a microfluidic pulse amplitude modulated ("PAM") chlorophyll fluorometer. The LOAC PAM chlorophyll fluorometer may analyze microalgae and cyanobacteria that grow naturally in source drinking water.

  5. Ultrashort-pulse laser calligraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Weijia; Kazansky, Peter G. [Optoelectronics Research Centre, University of Southampton, SO17 1BJ (United Kingdom); Shimotsuma, Yasuhiko; Sakakura, Masaaki; Miura, Kiyotaka; Hirao, Kazuyuki [Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510 (Japan)

    2008-10-27

    Control of structural modifications inside silica glass by changing the front tilt of an ultrashort pulse is demonstrated, achieving a calligraphic style of laser writing. The phenomena of anisotropic bubble formation at the boundary of an irradiated region and modification transition from microscopic bubbles formation to self-assembled form birefringence are observed, and the physical mechanisms are discussed. The results provide the comprehensive evidence that the light beam with centrosymmetric intensity distribution can produce noncentrosymmetric material modifications.

  6. Ultrashort-pulse laser calligraphy

    Science.gov (United States)

    Yang, Weijia; Kazansky, Peter G.; Shimotsuma, Yasuhiko; Sakakura, Masaaki; Miura, Kiyotaka; Hirao, Kazuyuki

    2008-10-01

    Control of structural modifications inside silica glass by changing the front tilt of an ultrashort pulse is demonstrated, achieving a calligraphic style of laser writing. The phenomena of anisotropic bubble formation at the boundary of an irradiated region and modification transition from microscopic bubbles formation to self-assembled form birefringence are observed, and the physical mechanisms are discussed. The results provide the comprehensive evidence that the light beam with centrosymmetric intensity distribution can produce noncentrosymmetric material modifications.

  7. a Portable Pulsed Neutron Generator

    Science.gov (United States)

    Skoulakis, A.; Androulakis, G. C.; Clark, E. L.; Hassan, S. M.; Lee, P.; Chatzakis, J.; Bakarezos, M.; Dimitriou, V.; Petridis, C.; Papadogiannis, N. A.; Tatarakis, M.

    2014-02-01

    The design and construction of a pulsed plasma focus device to be used as a portable neutron source for material analysis such as explosive detection using gamma spectroscopy is presented. The device is capable of operating at a repetitive rate of a few Hz. When deuterium gas is used, up to 105 neutrons per shot are expected to be produced with a temporal pulse width of a few tens of nanoseconds. The pulsed operation of the device and its portable size are its main advantage in comparison with the existing continuous neutron sources. Parts of the device include the electrical charging unit, the capacitor bank, the spark switch (spark gap), the trigger unit and the vacuum-fuel chamber / anode-cathode. Numerical simulations are used for the simulation of the electrical characteristics of the device including the scaling of the capacitor bank energies with total current, the pinch current, and the scaling of neutron yields with energies and currents. The MCNPX code is used to simulate the moderation of the produced neutrons in a simplified geometry and subsequently, the interaction of thermal neutrons with a test target and the corresponding prompt γ-ray generation.

  8. Complicated Laser Pulse Generation With Pulse Stacking for D-D ICF

    Institute of Scientific and Technical Information of China (English)

    GAO; Zhi-xing; WANG; Lei-jian; LU; Ze; ZHANG; Hai-feng

    2012-01-01

    <正>For direct drive fusion, a pre-distorted pulse with the complicated temporal shape is necessary. It is generally accepted that the pulse for shock ignition should begin with a low energy pre-pulse spike (picket) followed by a long (about 10 ns) low intensity foot pulse, which ramps up to an intermediate pedestal (compression pulse) and ends with a short high intensity spike.

  9. Efficient High-Energy Pulse-Train Generation Using a 2 n-Pulse Michelson Interferometer.

    Science.gov (United States)

    Siders, C W; Siders, J L; Taylor, A J; Park, S G; Weiner, A M

    1998-08-01

    We demonstrate a novel, Michelson-based, ultrafast multiplexer with a throughput approaching 100% for a polarization-multiplexed train and 50% for a linearly polarized train, which is compatible with a high-energy pulse train and shaped-pulse generation. The interpulse spacings in the resultant 2(n)-pulse train can be adjusted continuously from multinanoseconds through zero. Using this interferometer, we also demonstrate generation of a 16-pulse train of terahertz pulses.

  10. Method for Generating a Compressed Optical Pulse

    DEFF Research Database (Denmark)

    2015-01-01

    There is presented a method of for generating a compressed optical pulse (112) comprising emitting from a wavelength tunable microcavity laser system (102), comprising an optical cavity (104) with a mechanically adjustable cavity length (L), a primary optical pulse (111) having a primary temporal...... width (Tl) while adjusting the optical cavity length (L) so that said primary optical pulse comprises temporally separated photons of different wavelengths, and transmitting said pulse through a dispersive medium (114), so as to generate a compressed optical pulse (112) with a secondary temporal width...

  11. Optimal pseudorandom pulse position modulation ladar waveforms.

    Science.gov (United States)

    Fluckiger, David U; Boland, Brian F; Marcus, Eran

    2015-03-20

    An algorithm for generating optimal pseudorandom pulse position modulation (PRPPM) waveforms for ladar ranging is presented. Bistatic ladar systems using Geiger-mode avalanche photodiodes require detection of several pulses in order to generate sufficient target statistics to satisfy some detection decision rule. For targets with large initial range uncertainty, it becomes convenient to transmit a pulse train with large ambiguity range. One solution is to employ a PRPPM waveform. An optimal PRPPM waveform will have minimal sidelobes: equivalent to 1 or 0 counts after the pulse correlation filter (compression). This can be accomplished by generating PRPPM pulse trains with optimal or minimal sidelobe autocorrelation.

  12. Progress in time transfer by laser pulses

    Science.gov (United States)

    Li, Xin; Yang, Fu-Min

    2004-03-01

    Time transfer by laser pulses is based on the propagation of light pulses between satellite and ground clocks or between remote clocks on earth. It will realize the synchronization of these clocks with high accuracy and stability. Several experiments of the time transfer by laser pulses had been successfully carried out in some countries. These experiments validate the feasibility of the synchronization of clocks by laser pulses. The paper describes the results of these experiments. The time comparison by laser pulses between atomic clocks on aircraft and ground ones in the United States, and the LASSO and T2L2 projects in France are introduced in detail.

  13. Ion Acceleration by Short Chirped Laser Pulses

    Directory of Open Access Journals (Sweden)

    Jian-Xing Li

    2015-02-01

    Full Text Available Direct laser acceleration of ions by short frequency chirped laser pulses is investigated theoretically. We demonstrate that intense beams of ions with a kinetic energy broadening of about 1% can be generated. The chirping of the laser pulse allows the particles to gain kinetic energies of hundreds of MeVs, which is required for hadron cancer therapy, from pulses of energies in the order of 100 J. It is shown that few-cycle chirped pulses can accelerate ions more efficiently than long ones, i.e., higher ion kinetic energies are reached with the same amount of total electromagnetic pulse energy.

  14. Ion Acceleration by Short Chirped Laser Pulses

    CERN Document Server

    Li, Jian-Xing; Keitel, Christoph H; Harman, Zoltán

    2015-01-01

    Direct laser acceleration of ions by short frequency-chirped laser pulses is investigated theoretically. We demonstrate that intense beams of ions with a kinetic energy broadening of about 1 % can be generated. The chirping of the laser pulse allows the particles to gain kinetic energies of hundreds of MeVs, which is required for hadron cancer therapy, from pulses of energies of the order of 100 J. It is shown that few-cycle chirped pulses can accelerate ions more efficiently than long ones, i.e. higher ion kinetic energies are reached with the same amount of total electromagnetic pulse energy.

  15. Nutritional and health benefits of pulses.

    Science.gov (United States)

    Mudryj, Adriana N; Yu, Nancy; Aukema, Harold M

    2014-11-01

    Pulses (beans, peas, and lentils) have been consumed for at least 10 000 years and are among the most extensively used foods in the world. A wide variety of pulses can be grown globally, making them important both economically as well as nutritionally. Pulses provide protein and fibre, as well as a significant source of vitamins and minerals, such as iron, zinc, folate, and magnesium, and consuming half a cup of beans or peas per day can enhance diet quality by increasing intakes of these nutrients. In addition, the phytochemicals, saponins, and tannins found in pulses possess antioxidant and anti-carcinogenic effects, indicating that pulses may have significant anti-cancer effects. Pulse consumption also improves serum lipid profiles and positively affects several other cardiovascular disease risk factors, such as blood pressure, platelet activity, and inflammation. Pulses are high in fibre and have a low glycemic index, making them particularly beneficial to people with diabetes by assisting in maintaining healthy blood glucose and insulin levels. Emerging research examining the effect of pulse components on HIV and consumption patterns with aging populations indicates that pulses may have further effects on health. In conclusion, including pulses in the diet is a healthy way to meet dietary recommendations and is associated with reduced risk of several chronic diseases. Long-term randomized controlled trials are needed to demonstrate the direct effects of pulses on these diseases.

  16. The Pulse Line Ion Accelerator Concept

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Richard J.

    2006-02-15

    The Pulse Line Ion Accelerator concept was motivated by the desire for an inexpensive way to accelerate intense short pulse heavy ion beams to regimes of interest for studies of High Energy Density Physics and Warm Dense Matter. A pulse power driver applied at one end of a helical pulse line creates a traveling wave pulse that accelerates and axially confines the heavy ion beam pulse. Acceleration scenarios with constant parameter helical lines are described which result in output energies of a single stage much larger than the several hundred kilovolt peak voltages on the line, with a goal of 3-5 MeV/meter acceleration gradients. The concept might be described crudely as an ''air core'' induction linac where the PFN is integrated into the beam line so the accelerating voltage pulse can move along with the ions to get voltage multiplication.

  17. Pulse detonation engines and components thereof

    Science.gov (United States)

    Tangirala, Venkat Eswarlu (Inventor); Rasheed, Adam (Inventor); Vandervort, Christian Lee (Inventor); Dean, Anthony John (Inventor)

    2009-01-01

    A pulse detonation engine comprises a primary air inlet; a primary air plenum located in fluid communication with the primary air inlet; a secondary air inlet; a secondary air plenum located in fluid communication with the secondary air inlet, wherein the secondary air plenum is substantially isolated from the primary air plenum; a pulse detonation combustor comprising a pulse detonation chamber, wherein the pulse detonation chamber is located downstream of and in fluid communication with the primary air plenum; a coaxial liner surrounding the pulse detonation combustor defining a cooling plenum, wherein the cooling plenum is in fluid communication with the secondary air plenum; an axial turbine assembly located downstream of and in fluid communication with the pulse detonation combustor and the cooling plenum; and a housing encasing the primary air plenum, the secondary air plenum, the pulse detonation combustor, the coaxial liner, and the axial turbine assembly.

  18. Plasma response to transient high voltage pulses

    Indian Academy of Sciences (India)

    S Kar; S Mukherjee

    2013-07-01

    This review reports on plasma response to transient high voltage pulses in a low pressure unmagnetized plasma. Mainly, the experiments are reviewed, when a disc electrode (metallic and dielectric) is biased pulsed negative or positive. The main aim is to review the electron loss in plasmas and particle balance during the negative pulse electrode biasing, when the applied pulse width is less than the ion plasma period. Though the applied pulse width is less than the ion plasma period, ion rarefaction waves are excited. The solitary electron holes are reviewed for positive pulsed bias to the electrode. Also the excitation of waves (solitary electron and ion holes) is reviewed for a metallic electrode covered by a dielectric material. The wave excitation during and after the pulse withdrawal, excitation and propagation characteristics of various electrostatic plasma waves are reviewed here.

  19. Phytochemicals for health, the role of pulses.

    Science.gov (United States)

    Rochfort, Simone; Panozzo, Joe

    2007-10-03

    Pulses are the seeds of legumes that are used for human consumption and include peas, beans, lentils, chickpeas, and fava beans. Pulses are an important source of macronutrients, containing almost twice the amount of protein compared to cereal grains. In addition to being a source of macronutrients and minerals, pulses also contain plant secondary metabolites that are increasingly being recognised for their potential benefits for human health. The best-studied legume is the soybean, traditionally regarded as an oilseed crop rather than a pulse. The potential health benefits of soy, particularly with respect to isoflavone content, have been the subject of much research and the focus of several reviews. By comparison, less is known about pulses. This review investigates the health potential of pulses, examining the bioactivity of pulse isoflavones, phytosterols, resistant starch, bioactive carbohydrates, alkaloids and saponins. The evidence for health properties is considered, as is the effect of processing and cooking on these potentially beneficial phytochemicals.

  20. Slow light pulse propagation in dispersive media

    DEFF Research Database (Denmark)

    Nielsen, Torben Roland; Mørk, Jesper; Lavrinenko, Andrei

    2009-01-01

    -difference-time-domain Maxwell-Bloch simulations and compared to analytic results. For long pulses the group index (transmission) for the combined system is significantly enhanced (reduced) relative to slow light based on purely material or waveguide dispersion. Shorter pulses are strongly distorted and depending on parameters......We present a theoretical and numerical analysis of pulse propagation in a semiconductor photonic crystal waveguide with embedded quantum dots in a regime where the pulse is subjected to both waveguide and material dispersion. The group index and the transmission are investigated by finite...... broadening or break-up of the pulse may be observed. The transition from linear to nonlinear pulse propagation is quantified in terms of the spectral width of the pulse. To cite this article: T.R. Nielsen et al., C. R. Physique 10 (2009). (C) 2009 Academie des sciences. Published by Elsevier Masson SAS. All...

  1. Pulse-Flow Microencapsulation System

    Science.gov (United States)

    Morrison, Dennis R.

    2006-01-01

    The pulse-flow microencapsulation system (PFMS) is an automated system that continuously produces a stream of liquid-filled microcapsules for delivery of therapeutic agents to target tissues. Prior microencapsulation systems have relied on batch processes that involve transfer of batches between different apparatuses for different stages of production followed by sampling for acquisition of quality-control data, including measurements of size. In contrast, the PFMS is a single, microprocessor-controlled system that performs all processing steps, including acquisition of quality-control data. The quality-control data can be used as real-time feedback to ensure the production of large quantities of uniform microcapsules.

  2. High-Precision Pulse Generator

    Science.gov (United States)

    Katz, Richard; Kleyner, Igor

    2011-01-01

    A document discusses a pulse generator with subnanosecond resolution implemented with a low-cost field-programmable gate array (FPGA) at low power levels. The method used exploits the fast carry chains of certain FPGAs. Prototypes have been built and tested in both Actel AX and Xilinx Virtex 4 technologies. In-flight calibration or control can be performed by using a similar and related technique as a time interval measurement circuit by measuring a period of the stable oscillator, as the delays through the fast carry chains will vary as a result of manufacturing variances as well as the result of environmental conditions (voltage, aging, temperature, and radiation).

  3. High-power pulsed lasers

    Energy Technology Data Exchange (ETDEWEB)

    Holzrichter, J.F.

    1980-04-02

    The ideas that led to the successful construction and operation of large multibeam fusion lasers at the Lawrence Livermore Laboratory are reviewed. These lasers are based on the use of Nd:glass laser materials. However, most of the concepts are applicable to any laser being designed for fusion experimentation. This report is a summary of lectures given by the author at the 20th Scottish University Summer School in Physics, on Laser Plasma Interaction. This report includes basic concepts of the laser plasma system, a discussion of lasers that are useful for short-pulse, high-power operation, laser design constraints, optical diagnostics, and system organization.

  4. FPGA based pulsed NQR spectrometer

    Science.gov (United States)

    Hemnani, Preeti; Rajarajan, A. K.; Joshi, Gopal; Motiwala, Paresh D.; Ravindranath, S. V. G.

    2014-04-01

    An NQR spectrometer for the frequency range of 1 MHz to 5 MHZ has been designed constructed and tested using an FPGA module. Consisting of four modules viz. Transmitter, Probe, Receiver and computer controlled (FPGA & Software) module containing frequency synthesizer, pulse programmer, mixer, detection and display, the instrument is capable of exciting nuclei with a power of 200W and can detect signal of a few microvolts in strength. 14N signal from NaNO2 has been observed with the expected signal strength.

  5. Generation of few-cycle terawatt light pulses using optical parametric chirped pulse amplification.

    Science.gov (United States)

    Witte, S; Zinkstok, R; Hogervorst, W; Eikema, K

    2005-06-27

    We demonstrate the generation of 9.8+/-0.3 fs laser pulses with a peak power exceeding one terawatt at 30 Hz repetition rate, using optical parametric chirped pulse amplification. The amplifier is pumped by 140 mJ, 60 ps pulses at 532 nm, and amplifies seed pulses from a Ti:Sapphire oscillator to 23 mJ/pulse, resulting in 10.5 mJ/pulse after compression while amplified fluorescence is kept below 1%. We employ grating-based stretching and compression in combination with an LCD phase-shaper, allowing compression close to the Fourier limit of 9.3 fs.

  6. Upconversion chirped pulse amplification of ultrashort pulses using a multimode Tm:ZBLAN fiber

    Energy Technology Data Exchange (ETDEWEB)

    Yang, L.M.; Sosnowski, T.; Stock, M.L.; Norris, T.B.; Squier, J.; Mourou, G. [Univ. of Michigan, Ann Arbor, MI (United States). Center for Ultrafast Optical Science; Dennis, M.L.; Duling, I.N. III [Naval Research Lab., Washington, DC (United States)

    1995-11-01

    Microjoule pulse energies are achieved from a single stage upconversion fiber amplifier for the first time in this demonstration of chirped pulse amplification using a multimode TM:ZBLAN fiber. A Ti:sapphire laser system provides the seed pulse for the upconversion fiber amplifier which produces subpicosecond pulse trains with energies as great as 16 {micro}J at repetition rate of 4.4 kHz. The compressed, pulse peak power is more than 1 MW, and the pulse is characterized both temporally and spatially.

  7. Effects of pulse-to-pulse residual species on discharges in repetitively pulsed discharges through packed bed reactors

    Science.gov (United States)

    Kruszelnicki, Juliusz; Engeling, Kenneth W.; Foster, John E.; Kushner, Mark J.

    2016-09-01

    Atmospheric pressure dielectric barrier discharges (DBDs) sustained in packed bed reactors (PBRs) are being investigated for conversion of toxic and waste gases, and CO2 removal. These discharges are repetitively pulsed having varying flow rates and internal geometries, which results in species from the prior pulse still being in the discharge zone at the time the following discharge pulse occurs. A non-negligible residual plasma density remains, which effectively acts as preionization. This residual charge changes the discharge properties of subsequent pulses, and may impact important PBR properties such as chemical selectivity. Similarly, the residual neutral reactive species produced during earlier pulses will impact the reaction rates on subsequent pulses. We report on results of a computational investigation of a 2D PBR using the plasma hydrodynamics simulator nonPDPSIM. Results will be discussed for air flowing though an array of dielectric rods at atmospheric pressure. The effects of inter-pulse residual species on PBR discharges will be quantified. Means of controlling the presence of residual species in the reactor through gas flow rate, pulse repetition, pulse width and geometry will be described. Comparisons will be made to experiments. Work supported by US DOE Office of Fusion Energy Science and the National Science Foundation.

  8. Magnetization reversal in ultrashort magnetic field pulses

    CERN Document Server

    Bauer, M; Fassbender, J; Hillebrands, B

    2000-01-01

    We report the switching properties of a thin magnetic film subject to an ultrashort, laterally localized magnetic field pulse, obtained by numerical investigations. The magnetization distribution in the film is calculated on a grid assuming Stoner-like coherent rotation within the grid square size. Perpendicularly and in-plane magnetized films exhibit a magnetization reversal due to a 4 ps magnetic field pulse. Outside the central region the pulse duration is short compared to the precession period. In this area the evolution of the magnetization during the field pulse does not depend strongly on magnetic damping and/or pulse shape. However, the final magnetization distribution is affected by the magnetic damping. Although the pulse duration is short compared to the precession period, the time needed for the relaxation of the magnetization to the equilibrium state is rather large. The influence of the different magnetic anisotropy contributions and the magnetic damping parameter enters into the magnetization ...

  9. Thermoluminescence measurement technique using millisecond temperature pulses.

    Science.gov (United States)

    Manfred, Michael E; Gabriel, Nicholas T; Yukihara, Eduardo G; Talghader, Joseph J

    2010-06-01

    A measurement technique, pulsed thermoluminescence, is described which uses short thermal pulses to excite trapped carriers leading to radiative recombination. The pulses are obtained using microstructures with approximately 500 micros thermal time constants. The technique has many of the advantages of pulsed optically stimulated luminescence without the need for optical sources and filters to isolate the luminescent signal. Charge carrier traps in alpha-Al(2)O(3):C particles on microheaters were filled using 205 nm light. Temperature pulses of 10 and 50 ms were applied to the heaters and compared with a standard thermoluminescence curve taken at a ramp rate of 5 K s(-1). This produced curves of intensity verses temperature similar to standard thermoluminescence except shifted to higher temperatures. The luminescence of single particles was read multiple times with negligible loss of population. The lower limit of the duration of useful pulses appears to be limited by particle size and thermal contact between the particle and heater.

  10. Binary-phase compression of stretched pulses

    Science.gov (United States)

    Lozovoy, Vadim V.; Nairat, Muath; Dantus, Marcos

    2017-10-01

    Pulse stretching and compression are essential for the energy scale-up of ultrafast lasers. Here, we consider a radical approach using spectral binary phases, containing only two values (0 and π) for stretching and compressing laser pulses. We numerically explore different strategies and present results for pulse compression of factors up to a million back to the transform limit and experimentally obtain results for pulse compression of a factor of one hundred, in close agreement with numerical calculations. Imperfections resulting from binary-phase compression are addressed by considering cross-polarized wave generation filtering, and show that this approach leads to compressed pulses with contrast ratios greater than ten orders of magnitude. This new concept of binary-phase stretching and compression, if implemented in a multi-layer optic, could eliminate the need for traditional pulse stretchers and more importantly expensive compressors.

  11. The nonparaxial property of chirped pulsed beam

    Institute of Scientific and Technical Information of China (English)

    Daquan Lu(陆大全); Wei Hu(胡巍); Yizhou Zheng(郑一周); Zhenjun Yang(杨振军)

    2003-01-01

    The nonparaxial property of the chirped pulsed beam is analyzed both quantitatively and qualitatively.Through the qualitative investigation of the paraxial approximation condition, we show there are chirpinduced changes in the nonparaxial propagation of the chirped pulsed beam. A quantitative nonparaxial correction was developed by use of the perturbational technic and the Fourier transform for a few-cycle chirped pulsed beam with relative small chirp parameter. It was shown that the nonparaxial corrections were enhanced near the leading or trailing edge of pulse depending on weather the chirp parameter is positive or negative. An example for pulsed Gaussian beam driven by a chirped Gaussian pulse is shown in the numerical result to confirm our analysis.

  12. Pulse profile stability of the Crab pulsar

    CERN Document Server

    Jain, Chetana

    2011-01-01

    We present an X-ray timing analysis of the Crab pulsar, PSR B0531+21, using the archival RXTE data. We have investigated the stability of the Crab pulse profile, in soft (2-20 keV) and hard (30-100 keV) X-ray energies, over the last decade of RXTE operation. The analysis includes measurement of the separation between the two pulse peaks; and intensity and the widths of the two peaks. We did not find any significant time dependency in the pulse shape. The two peaks are stable in phase, intensity and widths, for the last ten years. The first pulse is relatively stronger at soft X-rays. The first pulse peak is narrower than the second peak, in both, soft- and hard X-ray energies. Both the peaks show a slow rise and a steeper fall. The ratio of the pulsed photons in the two peaks is also constant in time.

  13. Ionization of atoms by chirped attosecond pulses

    Institute of Scientific and Technical Information of China (English)

    Tan Fang; Peng Liang-You; Gong Qi-Huang

    2009-01-01

    We investigate the ionization dynamics of atoms by chirped attosecond pulses using the strong field approximation method. The pulse parameters are carefully chosen in the regime where the strong field approximation method is valid. We analyse the effects of the chirp of attosecond pulses on the energy distributions and the corresponding left-right asymmetry of the ionized electrons. For a single chirped attosecond pulse, the ionized electrons can be redistributed and the left-right asymmetry shows oscillations because of the introduction of the chirp. For time-delayed double attosecond pulses at different intensities with the weaker one chirped, exchanging the order of the two pulses shows a relative shift of the energy spectra, which can be explained by the different effective time delays of different frequency components because of the chirp.

  14. Conditions for effects of radiation pulsing

    CERN Document Server

    Trinkaus, H

    2002-01-01

    The possibility of pulsing effects on radiation damage is due to differences in the delay times of relevant defect reactions and/or to the non-linear dependence of such reactions on defect production rates. Thus, significant pulsing effects require (1) proper relationships of the internal time scales of defect production and reaction to the time scales of pulsing and (2) sufficiently large pulsing induced fluctuations in relevant microstructural variables. We show that the first condition, which we quantify by a 'relative dynamic bias', is indeed fulfilled in wide ranges of the main irradiation parameters. The second condition, quantified by an 'absolute dynamic bias', is, however, found to restrict the parameter ranges of possible pulsing effects substantially. For planned spallation neutron sources and similar accelerator driven systems facilities we find, for instance, that, in the temperature range of interest, the defect yield of one pulse (controlling the absolute dynamic bias) is much too small to allo...

  15. Chaotic carrier pulse position modulation communication system and method

    Science.gov (United States)

    Abarbanel, Henry D. I.; Larson, Lawrence E.; Rulkov, Nikolai F.; Sushchik, Mikhail M.; Tsimring, Lev S.; Volkovskii, Alexander R.

    2001-01-01

    A chaotic carrier pulse position modulation communication system and method is disclosed. The system includes a transmitter and receiver having matched chaotic pulse regenerators. The chaotic pulse regenerator in the receiver produces a synchronized replica of a chaotic pulse train generated by the regenerator in the transmitter. The pulse train from the transmitter can therefore act as a carrier signal. Data is encoded by the transmitter through selectively altering the interpulse timing between pulses in the chaotic pulse train. The altered pulse train is transmitted as a pulse signal. The receiver can detect whether a particular interpulse interval in the pulse signal has been altered by reference to the synchronized replica it generates, and can therefore detect the data transmitted by the receiver. Preferably, the receiver predicts the earliest moment in time it can expect a next pulse after observation of at least two consecutive pulses. It then decodes the pulse signal beginning at a short time before expected arrival of a pulse.

  16. Near-fault ground motions with prominent acceleration pulses: pulse characteristics and ductility demand

    Institute of Scientific and Technical Information of China (English)

    Mai Tong; Vladimir Rzhevsky; Dai Junwu; George C Lee; Qi Jincheng; Qi Xiaozhai

    2007-01-01

    Major earthquakes of last 15 years (e.g., Northridge 1994, Kobe 1995 and Chi-Chi 1999) have shown that many near-fault ground motions possess prominent acceleration pulses. Some of the prominent ground acceleration pulses are related to large ground velocity pulses, others are caused by mechanisms that are totally different from those causing the velocity pulses or fling steps. Various efforts to model acceleration pulses have been reported in the literature. In this paper, research results from a recent study of acceleration pulse prominent ground motions and an analysis of structural damage induced by acceleration pulses are summarized. The main results of the study include: (1) temporal characteristics of acceleration pulses; (2) ductility demand spectrum of simple acceleration pulses with respect to equivalent classes of dynamic systems and pulse characteristic parameters; and (3) estimation of fundamental period change under the excitation of strong acceleration pulses. By using the acceleration pulse induced linear acceleration spectrum and the ductility demand spectrum,a simple procedure has been developed to estimate the ductility demand and the fundamental period change of a reinforced concrete (RC) structure under the impact of a strong acceleration pulse.

  17. Pulsed UV and VUV excilamps

    Science.gov (United States)

    Tarasenko, Victor F.; Erofeev, Mikhail V.; Kostyrja, Igor D.; Lomaev, Mikhail I.; Rybka, Dmitri V.

    2008-05-01

    Emission characteristics of a nanosecond discharge in nitrogen, inert gases and its halogenides without preionization of the gap from an auxiliary source have been investigated. A volume discharge, initiated by an avalanche electron beam (VDIAEB) was realized at pressures up to 12 atm. It has been shown that at VDIAEB excitation no less than 90% energy in the 120-850 nm range is emitted by Xe, Kr, Ar dimers. Xenon spectra in the range 120-850 nm and time-amplitude characteristics have been recorded and analyzed for various excitation regimes. In xenon at pressure of 1.2 atm, the energy of spontaneous radiation in the full solid angle was ~ 45 mJ/cm3, and the FWHM of a radiation pulse was ~ 110 ns. The spontaneous radiation power rise in xenon was observed at pressures up to 12 atm. Pulsed power densities of radiation of inert gases halogenides excited by VDIAEB was ~ 4.5 kW/cm2 at efficiency up to 5.5 %.

  18. Calorimeter for pulsed energy sources

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, J.W.; Edmonds, P.H.

    1979-01-01

    A common problem in plasma physics experiments is the measurement of the energy deposited on a water-cooled plate by a pulsed energy source. Examples of this are neutral-beam-line defining plate and targets and tokamak water-cooled limiters. One method of measuring this energy is to integrate the product of the temperature rise (..delta..T) and the flow rate (F) of the coolant over the interval between the pulses. The two input parameters ..delta..T and F are derived from a differential thermopile and a turbine flow meter, respectively. A simple digital readout circuit displays the deposited energy in a light-emitting diode display. The circuit uses a commercially available, dual-slope analog-to-digital converter (ADC) in a novel configuration that multiplies ..delta..T and F directly. Calibration of the readout circuit is quick and simple, and short-term accuracies of 5% are easily obtained. Over longer periods the accuracy becomes degraded, primarily by thermal drifts in the thermopile amplifier and in the thermopile connections and the wiring. This offset must be compensated for by a simple adjustment before each experimental run. This readout circuit has been used successfully on the Impurity Study Experiment (ISX-B) neutral beam lines and is most convenient for deposited energy measurements in applications in which computerized data acquisition is not available.

  19. Pulse compression by use of deformable mirrors.

    Science.gov (United States)

    Zeek, E; Maginnis, K; Backus, S; Russek, U; Murnane, M; Mourou, G; Kapteyn, H; Vdovin, G

    1999-04-01

    An electrostatically deformable, gold-coated, silicon nitride membrane mirror was used as a phase modulator to compress pulses from 92 to 15 fs. Both an iterative genetic algorithm and single-step dispersion compensation based on frequency-resolved optical gating calibration of the mirror were used to compress pulses to within 10% of the transform limit. Frequency-resolved optical gating was used to characterize the pulses and to test the range of the deformable-mirror-based compressor.

  20. New pulse modulator with low switching frequency

    Directory of Open Access Journals (Sweden)

    Golub V. S.

    2014-12-01

    Full Text Available The author presents an integrating pulse modulator (analog signal converter with the pulse frequency and duration modulation similar to sigma-delta modulation (with low switching frequency, without quantization. The modulator is characterized by the absence of the quantization noise inherent in sigma-delta modulator, and a low switching frequency, unlike the pulse-frequency modulator. The modulator is recommended, in particular, to convert signals at the input of the class D power amplifier.

  1. PULSE DRYING EXPERIMENT AND BURNER CONSTRUCTION

    Energy Technology Data Exchange (ETDEWEB)

    Robert States

    2006-07-15

    Non steady impingement heat transfer is measured. Impingement heating consumes 130 T-BTU/Yr in paper drying, but is only 25% thermally efficient. Pulse impingement is experimentally shown to enhance heat transfer by 2.8, and may deliver thermal efficiencies near 85%. Experimental results uncovered heat transfer deviations from steady theory and from previous investigators, indicating the need for further study and a better theoretical framework. The pulse burner is described, and its roll in pulse impingement is analyzed.

  2. One laser pulse generates two photoacoustic signals

    OpenAIRE

    Gao, Fei; Feng, Xiaohua; Bai, Linyi; Zhang, Ruochong; Liu, Siyu; Ding, Ran; Kishor, Rahul; Zhao, Yanli; Zheng, Yuanjin

    2016-01-01

    Photoacoustic sensing and imaging techniques have been studied widely to explore optical absorption contrast based on nanosecond laser illumination. In this paper, we report a long laser pulse induced dual photoacoustic (LDPA) nonlinear effect, which originates from unsatisfied stress and thermal confinements. Being different from conventional short laser pulse illumination, the proposed method utilizes a long square-profile laser pulse to induce dual photoacoustic signals. Without satisfying...

  3. Subthreshold pair production in short laser pulses

    OpenAIRE

    Nousch, T.; Seipt, D.; Kampfer, B.; Titov, A. I.

    2012-01-01

    The $e^+e^-$ pair production by a probe photon traversing a linearly polarized laser pulse is treated as generalized nonlinear Breit-Wheeler process. For short laser pulses with very few oscillations of the electromagnetic field we find below the perturbative weak-field threshold $\\sqrt{s} = 2m$ a similar enhancement of the pair production rate as for circular polarization. The strong subthreshold enhancement is traced back to the finite bandwidth of the laser pulse. A folding model is develo...

  4. Picosecond Pulse Laser Microstructuring of silicon

    Institute of Scientific and Technical Information of China (English)

    赵明; 尹钢; 朱京涛; 赵利

    2003-01-01

    We report the experimental results of picosecond pulse laser microstructuring (pulse duration 35ps, wavelength 1.06μm, repetition rate 10Hz) of silicon using the direct focusing technique. Arrays of sharp conical spikes located below the initial surface have been formed by cumulative picosecond pulsed laser irradiation of silicon in SF6. Irradiation of silicon surface in air, N2, or vacuum creates ripple-like patterns, but does not create the sharp conical spikes.

  5. Multiple-beam pulse shaping and preamplification

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, R.B.; VanWonterghem, B.W.; Burkhart, S.C.; Davin, J.M.

    1994-11-09

    Glass fusion laser systems typically use a master oscillator-power amplifier (MOPA) architecture, where control of the optical pulse temporal and spatial parameters is accomplished mainly in the master oscillator and low power optics. The pulses from this low power ``front end`` are amplified in the power amplifier, which modifies the pulse shape temporally and spatially. Nonlinear frequency conversion crystals following the amplifier further change the pulse before it reaches the target. To effectively control the optical pulse on target for different types of experiments, and compensate for nonlinearity in the preceding optics, the front end system must be versatile enough to easily control many pulse parameters over a large range. The front end pulse generation system described in this article represents a new approach to this problem. The proposed National Ignition Facility (NIF) has 192 beamlines, each of which requires an input pulse of up to 12 Joules in around 4 ns equivalent square pulse length. Considerations of laser architecture for supplying each of these beamlines from a central oscillator system were crucial in the design of the front end. Previous lasers have used bulk optics to split a single oscillator signal and report beams to multiple amplifier chains. A key idea in the current design is to replace bulk optic transport with fibers, eliminating large opto-mechanical subsystems. Another important concept is convenient pulse forming using low voltage integrated optic modulators. The integrated optic and fiber optic concepts resulted in the current pulse generation designs for NEF. An important advantage is that each of the beamlines can have an independently controlled temporal pulse shape, which provides for precise balance of instantaneous power on target.

  6. Investigation of pulsed voltage limiters characteristics

    Directory of Open Access Journals (Sweden)

    Karimov A. V.

    2012-06-01

    Full Text Available A new method for measuring the voltage limit is offered. It has been designed to measure high-power pulsed current of voltage limiters. The error of this method is half as much as the error of the known method of direct measurement. The investigation of dependence of power capability of single-crystal and double-crystal voltage limiters and of the pulsed operation time on pulse duration.

  7. Pulsed Single Frequency MOPA Laser Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Latest advances in semiconductor optoelectronics makes it possible to develop compact light weight robust sources of coherent optical pulses, demanded for numerous...

  8. Ultrashort Laser Pulses in Biology and Medicine

    CERN Document Server

    Braun, Markus; Zinth, Wolfgang

    2008-01-01

    Sources of ultrashort laser pulses are nowadays commercially available and have entered many areas of research and development. This book gives an overview of biological and medical applications of these laser pulses. The briefness of these laser pulses permits the tracing of the fastest processes in photo-active bio-systems, which is one focus of the book. The other focus is applications that rely on the high peak intensity of ultrashort laser pulses. Examples covered span non-linear imaging techniques, optical tomography, and laser surgery.

  9. Directed cell movement in pulsed electric fields.

    Science.gov (United States)

    Franke, K; Gruler, H

    1994-01-01

    Human granulocytes exposed to pulsed electric guiding fields were investigated. The trajectories were determined from digitized pictures (phase contrast). The basic results are: (i) No directed response was induced by pulsed electric guiding fields having a zero averaged field. (ii) A directed response was induced by pulsed electric guiding fields having a non-zero averaged field. (iii) The directed response was enhanced for pulse sequences having a repetition time of 8 s. (iv) The lag-time between signal recognition and cellular response was 8-10 s. The results are discussed in the framework of a self-ignition model.

  10. Subthreshold pair production in short laser pulses

    CERN Document Server

    Nousch, T; Kampfer, B; Titov, A I

    2012-01-01

    The $e^+e^-$ pair production by a probe photon traversing a linearly polarized laser pulse is treated as generalized nonlinear Breit-Wheeler process. For short laser pulses with very few oscillations of the electromagnetic field we find below the perturbative weak-field threshold $\\sqrt{s} = 2m$ a similar enhancement of the pair production rate as for circular polarization. The strong subthreshold enhancement is traced back to the finite bandwidth of the laser pulse. A folding model is developed which accounts for the interplay of the frequency spectrum and the intensity distribution in the course of the pulse.

  11. Pulse front control with adaptive optics

    Science.gov (United States)

    Sun, B.; Salter, P. S.; Booth, M. J.

    2016-03-01

    The focusing of ultrashort laser pulses is extremely important for processes including microscopy, laser fabrication and fundamental science. Adaptive optic elements, such as liquid crystal spatial light modulators or membrane deformable mirrors, are routinely used for the correction of aberrations in these systems, leading to improved resolution and efficiency. Here, we demonstrate that adaptive elements used with ultrashort pulses should not be considered simply in terms of wavefront modification, but that changes to the incident pulse front can also occur. We experimentally show how adaptive elements may be used to engineer pulse fronts with spatial resolution.

  12. MEDEA II two-pulse generator development

    Science.gov (United States)

    Bieniosek, F. M.; Honig, J.; Theby, E. A.

    1990-06-01

    This article discusses improvements in the efficiency, output power, and operational flexibility of MEDEA II, a double-pulse electron beam accelerator at McDonnell Douglas Research Laboratories. A modified charging circuit, based on the triple-resonance pulse transformer concept, was implemented on both of MEDEA II's two stages. The output switches were modified to increase maximum output voltages, and a new, second output switch with asymmetric breakdown characteristics was developed. To avoid degradation of the second-pulse output waveform at the diode, a keep-alive circuit was installed. The effects of diode closure on double-pulse operation are also discussed.

  13. Light Pulses to Photomultipliers from Extended Scintillators

    CERN Document Server

    Boemi, D; CERN. Geneva; Costa, S; Insolia, A; Panebianco, S; Potenza, R; Randazzo, N; Reito, S; Romanski, J; Russo, G V; Tuvé, C

    1994-01-01

    Light pulses received by photomultipliers coupled to scintillators are investigated in the cases of long scintillator slats or rods as well as large disc-shaped ones and compared with pulses from point-like scintillators. Results of experimental tests for the disc-shaped configuration performed with the single photon counting technique are presented and compared with numerical calculations. The calculations were done describing light pulse shape by means of a quite new general analytical method based on virtual light paths and images from geometrical optics. The associated electric pulses from the photomultipliers are then discussed and their dependence from source-photocathode distance are put in light.

  14. A Pulsed Spectrometer Designed for Feedback NQR

    Science.gov (United States)

    Schiano, J. L.; Ginsberg, M. D.

    2000-02-01

    A pulsed NQR spectrometer specifically designed to facilitate real-time tuning of pulse sequence parameters is described. A modular approach based on the interconnection of several rack-mounted blocks provides easy access to all spectrometer signals and simplifies the task of modifying the spectrometer design. We also present experimental data that demonstrates the ability of the spectrometer to increase the signal to noise ratio of NQR measurements by automatically adjusting the pulse width in the strong off-resonant comb pulse sequence.

  15. Group velocity and pulse lengthening of mismatched laser pulses in plasma channels

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Carl; Benedetti, Carlo; Esarey, Eric; van Tilborg, Jeroen; Leemans, Wim

    2011-07-07

    Analytic solutions are presented to the non-paraxial wave equation describing an ultra-short, low-power, laser pulse propagating in aplasma channel. Expressions for the laser pulse centroid motion and laser group velocity are derived, valid for matched and mismatchedpropagation in a parabolic plasma channel, as well as in vacuum, for an arbitrary Laguerre-Gaussian laser mode. The group velocity of amismatched laser pulse, for which the laser spot size is strongly oscillating, is found to be independent of propagation distance andsignificantly less than that of a matched pulse. Laser pulse lengthening of a mismatched pulse owing to laser mode slippage isexamined and found to dominate over that due to dispersive pulse spreading for sufficiently long pulses. Analytic results are shown tobe in excellent agreement with numerical solutions of the full Maxwell equations coupled to the plasma response. Implications for plasmachannel diagnostics are discussed.

  16. Generation of laser pulse trains for tests of multi-pulse laser wakefield acceleration

    Science.gov (United States)

    Shalloo, R. J.; Corner, L.; Arran, C.; Cowley, J.; Cheung, G.; Thornton, C.; Walczak, R.; Hooker, S. M.

    2016-09-01

    In multi-pulse laser wakefield acceleration (MP-LWFA) a plasma wave is driven by a train of low-energy laser pulses separated by the plasma period, an approach which offers a route to driving plasma accelerators with high efficiency and at high pulse repetition rates using emerging technologies such as fibre and thin-disk lasers. Whilst these laser technologies are in development, proof-of-principle tests of MP-LWFA require a pulse train to be generated from a single, high-energy ultrafast pulse. Here we demonstrate the generation of trains of up to 7 pulses with pulse separations in the range 150-170 fs from single 40 fs pulses produced by a Ti:sapphire laser.

  17. A Mutual Pulse Injection-Seeding Scheme for Optical Short Pulse Generation

    Institute of Scientific and Technical Information of China (English)

    D.; N.; Wang

    2003-01-01

    A mutual pulse injection-seeding scheme is developed to produce wavelength tunable optical short pulse generation. The sidemode suppression ratio obtained is more than 31 dB over the wavelength-tuning rang of 18 nm.

  18. Generation of laser pulse trains for tests of multi-pulse laser wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Shalloo, R.J., E-mail: robert.shalloo@physics.ox.ac.uk; Corner, L.; Arran, C.; Cowley, J.; Cheung, G.; Thornton, C.; Walczak, R.; Hooker, S.M.

    2016-09-01

    In multi-pulse laser wakefield acceleration (MP-LWFA) a plasma wave is driven by a train of low-energy laser pulses separated by the plasma period, an approach which offers a route to driving plasma accelerators with high efficiency and at high pulse repetition rates using emerging technologies such as fibre and thin-disk lasers. Whilst these laser technologies are in development, proof-of-principle tests of MP-LWFA require a pulse train to be generated from a single, high-energy ultrafast pulse. Here we demonstrate the generation of trains of up to 7 pulses with pulse separations in the range 150–170 fs from single 40 fs pulses produced by a Ti:sapphire laser.

  19. Generalized Short Pulse Equation for Propagation of Few-Cycle Pulses in Metamaterials

    CERN Document Server

    Pietrzyk, Monika E

    2016-01-01

    We show that propagation of ultrashort (few-cycle) pulses in nonlinear Drude metamaterials with both electric and magnetic Kerr nonlinearities is described by coupled generalized Short Pulse Equations. The resulting system of equations generalizes to the case of metamaterials both the Short Pulse Equation and its vector generalizations which describe the few-cycle pulses in dielectric optical fibers beyond the slowly varying envelope approximation leading to the nonlinear Schroedinger equation.

  20. Efficient chirped-pulse amplification of sub-20 fs laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Shinichi; Yamakawa, Koichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    We have developed a model for ultrabroadband and ultrashort pulse amplification including the effects of a pulse shaper for regenerative pulse shaping, gain narrowing and gain saturation in the amplifiers. Thin solid etalons are used to control both gain narrowing and gain saturation during amplification. This model has been used to design an optimized Ti:sapphire amplifier system for producing efficiently pulses of < 20-fs duration with approaching peak and average powers of 100 TW and 20 W. (author)