WorldWideScience

Sample records for pull-down abdominal flap

  1. The Pedicled LICAP Flap Combined with a Free Abdominal Flap In Autologous Breast Reconstructions

    Directory of Open Access Journals (Sweden)

    Thomas Sjøberg, MD

    2018-01-01

    Conclusion:. In selected patients with insufficient abdominal flap tissue, a combination of a free abdominal flap and a pedicled LICAP flap is a valuable option to increase breast size and cosmetic outcome. Additional symmetrizing surgery might still be necessary.

  2. Banking a hemi-abdominal DIEP flap: a pilot report of indications, technique, and utility.

    Science.gov (United States)

    Shridharani, Sachin M; Singh, Navin K; Taylor, Jesse A; Rosson, Gedge D

    2009-01-01

    We present a pilot report of "banking" the contralateral hemi-abdominal deep inferior epigastric perforator (DIEP) flap under the abdominal closure in patients undergoing unilateral autologous breast reconstruction when a hemi-abdominal flap suffices. Four patients undergoing unilateral autologous breast reconstruction with a hemi-abdominal DIEP or superficial inferior epigastric artery flap had their contralateral hemi-abdominal flap left in position, or "banked," under their abdominal closure to be used in case of failure. This novel method may be of assistance when a free microvascular hemi-abdominal flap is felt to be threatened or suspect. It provides a life-boat for the younger and experienced surgeon alike, and most importantly, for the breast cancer survivor. Economic analysis of the technique reveals that the contralateral hemi-abdominal flap should be banked more often than intuition alone would suggest. (c) 2009 Wiley-Liss, Inc.

  3. Lower abdominal wall reconstructions with pedicled rectus femoris flaps

    International Nuclear Information System (INIS)

    Arashiro, Ken; Nishizeki, Osamu; Ishida, Kunihiro

    2003-01-01

    During the past 10 years, seven pedicled rectus femoris muscle or musculocutaneous flaps were used to repair lower abdominal defects; three recalcitrant incisional hernias with previous radiotherapy, two long-standing wound infections after synthetic mesh reconstruction, one posttraumatic wall defect and one metastatic tumor. There were two flap complications, one skin paddle necrosis and one wound infection. There was no significant disability of the donor limb encountered. During the two-year and seven month average follow-up, there was no recurrence of the problems except for one minor fascial dehiscence in the patient with metastatic abdominal wall tumor. Easy approach, rapid harvest, relatively large and reliable overlying fascia lata, a single dominant neurovascular pedicle, easy primary closure of the donor site, and minimal donor site morbidity all make the rectus femoris flap a good alternative flap for lower abdominal wall reconstruction. It is especially useful in a condition where synthetic mesh would be unsuitable for defects with infection or recurrent incisional hernia after radiotherapy. (author)

  4. Internal Mammary Vessels’ Impact on Abdominal Skin Perfusion in Free Abdominal Flap Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Solveig Nergård, MD

    2017-12-01

    Conclusions:. Using the IMV in free abdominal flap breast reconstruction had a significant effect on abdominal skin perfusion and may contribute to abdominal wound healing problems. The reperfusion of the abdominal skin was a dynamic process showing an increase in perfusion in the affected areas during the postoperative days.

  5. Abdominal wall reconstruction using De-epithelialized dermal flap: A ...

    African Journals Online (AJOL)

    Abdominal wall reconstruction using De-epithelialized dermal flap: A new technique. ... Journal of Surgical Technique and Case Report ... Background: Although autogenous materials have been used in abdominal wall hernioplasty for a long time, the introduction of prosthetic materials diminished their popularity. However ...

  6. Fournier?s gangrene - delayed pedicle flap based upon the anterior abdominal wall

    Directory of Open Access Journals (Sweden)

    Ania Sliwinski

    2014-06-01

    Full Text Available Introduction Fournier’s gangrene is a poly-microbial necrotizing fasciitis that involves the perineum and/or external genitalia. Urgent surgical debridement is well recognized as essential acute treatment yet unique challenges arise for plastic surgical reconstruction to obtain a complete functional recovery. This case describes a successful delayed pedicle flap repair based upon the anterior abdominal wall. Case description A 24 year old man was admitted to ICU ten days after elective circumcision with Fournier’s gangrene. He underwent a number of surgical debridements, and was referred for plastic surgical management. He had penile reconstruction using a random pattern abdominal flap, which was performed as a three stage procedure including flap vascular delay technique. Discussion Perineal and penile skin loss can be significant and is difficult to repair. Various techniques have been used to reconstruct lost tissue: skin grafts, transposition of the testes and spermatic cords to the thigh, flaps, and other types of pediculated myocutaneous flaps. Muscle flap reconstruction provides an environment that allows for complete regeneration of the urethral epithelium but is bulky and unsightly. Skin grafts contract and may produce painful and dysfunctional reconstructions. This novel technique produces a functional, and aesthetic reconstruction. Conclusion Penile skin recovery following Fournier’s gangrene recovery is problematic. This case demonstrates the functionality of a delayed flap repair using the anterior abdominal wall.

  7. On-bead chemical synthesis and display of phosphopeptides for affinity pull-down proteomics

    DEFF Research Database (Denmark)

    Malene, Brandt; Madsen, Jens C.; Bunkenborg, Jakob

    2006-01-01

    We describe a new method for phosphopeptide proteomics based on the solid-phase synthesis of phosphopeptides on beads suitable for affinity pull-down experiments. Peptide sequences containing the Bad Ser112 and Ser136 phosphorylation motifs were used as bait in affinity pull-down experiments...... (aldehyde) at the C terminus for potential activity-based proteomics. The synthetic support-bound Bad phosphopeptides were able to pull down 14-3-3zeta. Furthermore, Bad phosphopeptides bound endogenous 14-3-3 proteins, and all seven members of the 14-3-3 family were identified by mass spectrometry....... In control experiments, none of the unphosphorylated Bad peptides bound transfected 14-3-3zeta or endogenous 14-3-3. We conclude that the combined synthesis and display of phosphopeptides on-bead is a fast and efficient method for affinity pull-down proteomics....

  8. The Use of Tensor Fascia Lata Pedicled Flap in Reconstructing Full Thickness Abdominal Wall Defects and Groin Defects Following Tumor Ablation

    International Nuclear Information System (INIS)

    Rifaat, M.A.; Abdel Gawad, W.S.

    2005-01-01

    The tensor fascia lata is a versatile flap with many uses in reconstructive plastic surgery. As a pedicled flap its reach to the lower abdomen and groin made it an attractive option for reconstructing soft tissue defects after tumor ablation. However, debate exists on the safe dimension of the flap, as distal tip necrosis is common. Also, the adequacy of the fascia lata as a sole substitute for abdominal wall muscles has been disputable. The aim of the current study is to report our experience and clinical observations with this flap in reconstructing those challenging defects and to discuss the possible options to minimize the latter disputable issues. Patients and Methods: From April 2001 to April 2004, 12 pedicled TFL flaps were used to reconstruct 5 central abdominal wall full thickness defects and 6 groin soft tissue defects following tumor resection. ]n one case, bilateral flaps were used to reconstruct a large central abdominal wall defect. There were 4 males and 7 females. Their age ranged from 19 to 60. From the abdominal wall defects group, all repairs were enforced primarily with a prolene mesh except for one patient who was the first in this study. Patients presenting with groin defects required coverage of exposed vessels following tumor resection. All patients in the current study underwent immediate reconstruction. The resulting soft tissue defects in this study were due to resection of 4 abdominal wall desmoid tumors, a colonic carcinoma infiltrating the abdominal wall, 4 primary groin soft developed in a flap used to cover a groin defect. In the former 3 cases, The flap was simply transposed without complete islanding of the flap. In the latter case, a very large flap was harvested beyond the safe limits with its distal edge just above the knee. In addition, wound dehiscence of the flap occurred in 2 other cases from the groin group. Nevertheless, all the wounds healed spontaneously with repeated dressings. Out of the 5 cases that underwent

  9. Patients' Aesthetic Concerns After Horizontally Placed Abdominal Free Flap Breast Reconstruction.

    Science.gov (United States)

    Kim, Eun Key; Suh, Young Chul; Maldonado, Andrés A; Yun, Jiyoung; Lee, Taik Jong

    2015-10-01

    The present study aimed to analyze patients' aesthetic concerns after breast reconstruction with abdominal free flap by reporting secondary cosmetic procedures performed based on the patients' request, and analyzed the effect of adjuvant therapies and other variables on such outcomes. All patients who underwent unilateral immediate reconstruction were enrolled prospectively. Free abdominal flaps were placed horizontally with little manipulation. Secondary procedures were actively recommended during the follow-up period to meet the patients' aesthetic concerns. The numbers and types of the secondary procedures and the effects of various factors were analyzed. 150 patients met the eligibility criteria. The average number of overall secondary surgeries per patient was 1.25. Patients with skin-sparing mastectomy required significantly higher number of secondary surgeries compared with those who underwent nipple-areolar skin-sparing mastectomy. When confined to the cosmetic procedures, 58 (38.7 %) patients underwent 75 operations. The most common procedures were flank dog ear revision, fat injection of the reconstructed breast, and breast liposuction. None of the radiated patients underwent liposuction of the flap. Most commonly liposuctioned regions were the central-lateral and lower-lateral, while fat was most commonly injected to the upper-medial and upper-central part of the breast. The present study delineated the numbers and types of the secondary operations after horizontally placed abdominal free flap transfer with analysis of the influence of various factors. Addressing such issues during the primary reconstruction would help to reduce the need and extent of the secondary operations and to maximize aesthetic outcome. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Decision making in double-pedicled DIEP and SIEA abdominal free flap breast reconstructions: An algorithmic approach and comprehensive classification.

    Directory of Open Access Journals (Sweden)

    Charles M Malata

    2015-10-01

    Full Text Available Introduction: The deep inferior epigastric artery perforator (DIEP free flap is the gold standard for autologous breast reconstruction. However, using a single vascular pedicle may not yield sufficient tissue in patients with midline scars or insufficient lower abdominal pannus. Double-pedicled free flaps overcome this problem using different vascular arrangements to harvest the entire lower abdominal flap. The literature is, however, sparse regarding technique selection. We therefore reviewed our experience in order to formulate an algorithm and comprehensive classification for this purpose. Methods: All patients undergoing unilateral double-pedicled abdominal perforator free flap breast reconstruction (AFFBR by a single surgeon (CMM over 40 months were reviewed from a prospectively collected database. Results: Of the 112 consecutive breast free flaps performed, 25 (22% utilised two vascular pedicles. The mean patient age was 45 years (range=27-54. All flaps but one (which used the thoracodorsal system were anastomosed to the internal mammary vessels using the rib-preservation technique. The surgical duration was 656 minutes (range=468-690 mins. The median flap weight was 618g (range=432-1275g and the mastectomy weight was 445g (range=220-896g. All flaps were successful and only three patients requested minor liposuction to reduce and reshape their reconstructed breasts.Conclusion: Bipedicled free abdominal perforator flaps, employed in a fifth of all our AFFBRs, are a reliable and safe option for unilateral breast reconstruction. They, however, necessitate clear indications to justify the additional technical complexity and surgical duration. Our algorithm and comprehensive classification facilitate technique selection for the anastomotic permutations and successful execution of these operations.

  11. Reconstruction of Abdominal Wall of a Chronically Infected Postoperative Wound with a Rectus Abdominis Myofascial Splitting Flap

    Directory of Open Access Journals (Sweden)

    Sung Kyu Bae

    2013-01-01

    Full Text Available Background If a chronically infected abdominal wound develops, complications such asperitonitis and an abdominal wall defect could occur. This could prolong the patient’s hospitalstay and increase the possibility of re-operation or another infection as well. For this reason,a solution for infection control is necessary. In this study, surgery using a rectus abdominismuscle myofascial splitting flap was performed on an abdominal wall defect.Methods From 2009 to 2012, 5 patients who underwent surgery due to ovarian rupture,cesarean section, or uterine myoma were chosen. In each case, during the first week afteroperation, the wound showed signs of infection. Surgery was chosen because the wounds didnot resolve with dressing. Debridement was performed along the previous operation woundand dissection of the skin was performed to separate the skin and subcutaneous tissue fromthe attenuated rectus muscle and Scarpa’s fascial layers. Once the anterior rectus sheath andmuscle were adequately mobilized, the fascia and muscle flap were advanced medially sothat the skin defect could be covered for reconstruction.Results Upon 3-week follow-up after a rectus abdominis myofascial splitting flap operation,no major complication occurred. In addition, all of the patients showed satisfaction in termsof function and esthetics at 3 to 6 months post-surgery.Conclusions Using a rectus abdominis myofascial splitting flap has many esthetic andfunctional benefits over previous methods of abdominal defect treatment, and notably, itenabled infection control by reconstruction using muscle.

  12. Reconstruction of Abdominal Wall of a Chronically Infected Postoperative Wound with a Rectus Abdominis Myofascial Splitting Flap

    Directory of Open Access Journals (Sweden)

    Sung Kyu Bae

    2013-01-01

    Full Text Available BackgroundIf a chronically infected abdominal wound develops, complications such as peritonitis and an abdominal wall defect could occur. This could prolong the patient's hospital stay and increase the possibility of re-operation or another infection as well. For this reason, a solution for infection control is necessary. In this study, surgery using a rectus abdominis muscle myofascial splitting flap was performed on an abdominal wall defect.MethodsFrom 2009 to 2012, 5 patients who underwent surgery due to ovarian rupture, cesarean section, or uterine myoma were chosen. In each case, during the first week after operation, the wound showed signs of infection. Surgery was chosen because the wounds did not resolve with dressing. Debridement was performed along the previous operation wound and dissection of the skin was performed to separate the skin and subcutaneous tissue from the attenuated rectus muscle and Scarpa's fascial layers. Once the anterior rectus sheath and muscle were adequately mobilized, the fascia and muscle flap were advanced medially so that the skin defect could be covered for reconstruction.ResultsUpon 3-week follow-up after a rectus abdominis myofascial splitting flap operation, no major complication occurred. In addition, all of the patients showed satisfaction in terms of function and esthetics at 3 to 6 months post-surgery.ConclusionsUsing a rectus abdominis myofascial splitting flap has many esthetic and functional benefits over previous methods of abdominal defect treatment, and notably, it enabled infection control by reconstruction using muscle.

  13. Successful Deep Inferior Epigastric Perforator Flap Harvest despite Preoperative Therapeutic Subcutaneous Heparin Administration into the Abdominal Pannus.

    Science.gov (United States)

    Duncumb, Joseph W; Miyagi, Kana; Forouhi, Parto; Malata, Charles M

    2016-01-01

    Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP) flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™) used for administering primary chemotherapy in breast cancer.

  14. Successful Deep Inferior Epigastric Perforator Flap Harvest despite Preoperative Therapeutic Subcutaneous Heparin Administration into the Abdominal Pannus

    Directory of Open Access Journals (Sweden)

    Joseph W. Duncumb

    2016-01-01

    Full Text Available Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™ used for administering primary chemotherapy in breast cancer.

  15. Relative quantification of protein-protein interactions using a dual luciferase reporter pull-down assay system.

    Directory of Open Access Journals (Sweden)

    Shuaizheng Jia

    Full Text Available The identification and quantitative analysis of protein-protein interactions are essential to the functional characterization of proteins in the post-proteomics era. The methods currently available are generally time-consuming, technically complicated, insensitive and/or semi-quantitative. The lack of simple, sensitive approaches to precisely quantify protein-protein interactions still prevents our understanding of the functions of many proteins. Here, we develop a novel dual luciferase reporter pull-down assay by combining a biotinylated Firefly luciferase pull-down assay with a dual luciferase reporter assay. The biotinylated Firefly luciferase-tagged protein enables rapid and efficient isolation of a putative Renilla luciferase-tagged binding protein from a relatively small amount of sample. Both of these proteins can be quantitatively detected using the dual luciferase reporter assay system. Protein-protein interactions, including Fos-Jun located in the nucleus; MAVS-TRAF3 in cytoplasm; inducible IRF3 dimerization; viral protein-regulated interactions, such as MAVS-MAVS and MAVS-TRAF3; IRF3 dimerization; and protein interaction domain mapping, are studied using this novel assay system. Herein, we demonstrate that this dual luciferase reporter pull-down assay enables the quantification of the relative amounts of interacting proteins that bind to streptavidin-coupled beads for protein purification. This study provides a simple, rapid, sensitive, and efficient approach to identify and quantify relative protein-protein interactions. Importantly, the dual luciferase reporter pull-down method will facilitate the functional determination of proteins.

  16. Paravertebral and Brachial plexus block for Abdominal flap to cover the upper limb wound

    Directory of Open Access Journals (Sweden)

    Narendra kumar

    2011-08-01

    Full Text Available We present a case report where thoracic paravertebral block and brachial plexus block were used in a sick elderly patient with poor cardiopulmonary reserve, to cover a post traumatic raw area of the upper limb by raising flap from lateral abdominal wall. The residual raw area of abdomen was then covered with the split skin graft taken from thigh.

  17. Single-molecule pull-down (SiMPull) for new-age biochemistry: methodology and biochemical applications of single-molecule pull-down (SiMPull) for probing biomolecular interactions in crude cell extracts.

    Science.gov (United States)

    Aggarwal, Vasudha; Ha, Taekjip

    2014-11-01

    Macromolecular interactions play a central role in many biological processes. Protein-protein interactions have mostly been studied by co-immunoprecipitation, which cannot provide quantitative information on all possible molecular connections present in the complex. We will review a new approach that allows cellular proteins and biomolecular complexes to be studied in real-time at the single-molecule level. This technique is called single-molecule pull-down (SiMPull), because it integrates principles of conventional immunoprecipitation with the powerful single-molecule fluorescence microscopy. SiMPull is used to count how many of each protein is present in the physiological complexes found in cytosol and membranes. Concurrently, it serves as a single-molecule biochemical tool to perform functional studies on the pulled-down proteins. In this review, we will focus on the detailed methodology of SiMPull, its salient features and a wide range of biological applications in comparison with other biosensing tools. © 2014 WILEY Periodicals, Inc.

  18. Management of Anterior Abdominal Wall Defect Using a Pedicled Tensor Fascia Lata Flap: A Case Report

    Directory of Open Access Journals (Sweden)

    K. D. Ojuka

    2012-01-01

    Full Text Available Degloving injuries to anterior abdominal wall are rare due to the mechanism of injury. Pedicled tensor fascia lata is known to be a versatile flap with ability to reach the lower anterior abdomen. A 34-year-old man who was involved in a road traffic accident presented with degloving injury and defect at the left inguinal region, sigmoid colon injury, and scrotal bruises. At investigation, he was found to have pelvic fracture. The management consisted of colostomy and tensor fascia lata to cover the defect at reversal. Though he developed burst abdomen on fifth postoperative day, the flap healed with no complications.

  19. Ring down artefacts on abdominal sonography to predict pulmonary abnormalities in the emergency department.

    Science.gov (United States)

    Tsai, C-L; Wang, H-P; Lien, W-C; Chen, C-C; Lai, T-I; Chen, W-J

    2005-10-01

    Ring down artefacts are sometimes found when emergency physicians perform abdominal ultrasound to differentiate between various abdominal problems. We describe a patient who presented with right upper quadrant abdominal pain and whose ultrasound examination showed ring down artefacts posterior to the right hemidiaphragm, which led to the eventual diagnosis of pneumonia. Ring down artefacts on ultrasound may be used to predict pulmonary abnormalities. Awareness of this sonographic finding may assist in accurate diagnosis and administration of appropriate treatment without delay.

  20. DIEP breast reconstruction following multiple abdominal liposuction procedures

    OpenAIRE

    Farid, Mohammed; Nicholson, Simon; Kotwal, Ashutosh; Akali, Augustine

    2014-01-01

    Objective: Previous abdominal wall surgery is viewed as a contraindication to abdominal free tissue transfer. We present two patients who underwent multiple abdominal liposuction procedures, followed by successful free deep inferior epigastric artery perforator flap. We review the literature pertaining to reliability of abdominal free flaps in those with previous abdominal surgery. Methods: Review of case notes and radiological investigations of two patients, and a PubMed search using the ter...

  1. Modifications of micro-pulling-down method for the growth of selected Li-containing crystals for neutron scintillator and VUV scintillation crystals

    Science.gov (United States)

    Pejchal, J.; Fujimoto, Y.; Chani, V.; Yanagida, T.; Yokota, Y.; Yoshikawa, A.; Nikl, M.; Beitlerova, A.

    2012-12-01

    To develop new and efficient neutron scintillator, Ti-doped LiAlO2 single crystal was grown by micro-pulling-down method. The X-ray excited radioluminescence spectra and neutron light yield were measured. Positive effect of Mg codoping on the overall scintillation efficiency was found. The BaLu2F8 single crystal was grown by micro-pulling-down method using low temperature gradient at growth interface and applying quenching immediately after growth process.

  2. Modelling of Spring Constant and Pull-down Voltage of Non-uniform RF MEMS Cantilever Incorporating Stress Gradient

    Directory of Open Access Journals (Sweden)

    Shimul Chandra SAHA

    2008-11-01

    Full Text Available We have presented a model for spring constant and pull-down voltage of a non-uniform radio frequency microelectromechanical systems (RF MEMS cantilever that works on electrostatic actuation. The residual stress gradient in the beam material that may arise during the fabrication process is also considered in the model. Using basic force deflection calculation of the suspended beam, a stand-alone model for the spring constant and pull-down voltage of the non-uniform cantilever is developed. To compare the model, simulation is performed using standard Finite Element Method (FEM analysis tolls from CoventorWare. The model matches very well with the FEM simulation results. The model will offer an efficient means of design, analysis, and optimization of RF MEMS cantilever switches.

  3. DIEP breast reconstruction following multiple abdominal liposuction procedures.

    Science.gov (United States)

    Farid, Mohammed; Nicholson, Simon; Kotwal, Ashutosh; Akali, Augustine

    2014-01-01

    Previous abdominal wall surgery is viewed as a contraindication to abdominal free tissue transfer. We present two patients who underwent multiple abdominal liposuction procedures, followed by successful free deep inferior epigastric artery perforator flap. We review the literature pertaining to reliability of abdominal free flaps in those with previous abdominal surgery. Review of case notes and radiological investigations of two patients, and a PubMed search using the terms "DIEP", "deep inferior epigastric", "TRAM", "transverse rectus abdominis", "perforator" and "laparotomy", "abdominal wall", "liposuction", "liposculpture", "fat graft", "pfannenstiel", with subsequent appraisal of relevant papers by the first and second authors. Patient 1 had 3 episodes of liposuction from the abdomen for fat grafting to a reconstructed breast. Subsequent revision reconstruction of the same breast with DIEP flap was preceded by CT angiography, which demonstrated normal perforator anatomy. The reconstruction healed well with no ischaemic complications. Patient 2 had 5 liposuction procedures from the abdomen to graft fat to a wide local excision defect. Recurrence of cancer led to mastectomy and immediate reconstruction with free DIEP flap. Preoperative MR angiography demonstrated a large perforator right of the umbilicus, with which the intraoperative findings were consistent. The patient had an uneventful recovery and good healing with no fat necrosis or wound dehiscence. We demonstrate that DIEP flaps can safely be raised without perfusion-related complications following multiple liposuction procedures to the abdomen. The safe interval between procedures is difficult to quantify, but we demonstrate successful free flap after 16 months.

  4. Delayed pull-in transitions in overdamped MEMS devices

    Science.gov (United States)

    Gomez, Michael; Moulton, Derek E.; Vella, Dominic

    2018-01-01

    We consider the dynamics of overdamped MEMS devices undergoing the pull-in instability. Numerous previous experiments and numerical simulations have shown a significant increase in the pull-in time under DC voltages close to the pull-in voltage. Here the transient dynamics slow down as the device passes through a meta-stable or bottleneck phase, but this slowing down is not well understood quantitatively. Using a lumped parallel-plate model, we perform a detailed analysis of the pull-in dynamics in this regime. We show that the bottleneck phenomenon is a type of critical slowing down arising from the pull-in transition. This allows us to show that the pull-in time obeys an inverse square-root scaling law as the transition is approached; moreover we determine an analytical expression for this pull-in time. We then compare our prediction to a wide range of pull-in time data reported in the literature, showing that the observed slowing down is well captured by our scaling law, which appears to be generic for overdamped pull-in under DC loads. This realization provides a useful design rule with which to tune dynamic response in applications, including state-of-the-art accelerometers and pressure sensors that use pull-in time as a sensing mechanism. We also propose a method to estimate the pull-in voltage based only on data of the pull-in times.

  5. Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.

    Science.gov (United States)

    Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M

    2016-02-01

    Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.

  6. A case of incisional hernia repair using Composix mesh prosthesis after antethoracic pedicled jejunal flap reconstruction following an esophagectomy.

    Science.gov (United States)

    Yasuda, Atsushi; Yasuda, Takushi; Kato, Hiroaki; Iwama, Mitsuru; Shiraishi, Osamu; Hiraki, Yoko; Tanaka, Yumiko; Shinkai, Masayuki; Imano, Motohiro; Kimura, Yutaka; Imamoto, Haruhiko

    2017-12-01

    An incisional hernia in a case of antethoracic pedicled jejunal flap esophageal reconstruction after esophagectomy is a very rare occurrence, and this hernia was distinctive in that the reconstructed jejunum had passed through the hernial orifice; a standard surgical treatment for such a presentation has not been established. Herein, we describe a case of repair using mesh prosthesis for an atypical and distinctive incisional hernia after antethoracic pedicled jejunal flap esophageal reconstruction. A 77-year-old woman with a history of subtotal esophagectomy who had undergone antethoracic pedicled jejunal flap reconstruction complained of epigastric prominence and discomfort without pain. On examination, she had an abdominal protrusion between the xiphoid process and the umbilicus that contained the small bowel. Computed tomography showed that the fenestration of the abdominal wall that was intentionally created for jejunum pull-up was dehisced in a region measuring 9 × 15 cm and the small intestine protruded through it into the subcutaneous space without strangulation. Because the hernial orifice was too large and the reconstructed jejunum was passing through the hernial orifice in this case, we applied a parastomal hernia repair method that was modified from the inguinal hernia repair using the Lichtenstein technique. After 3 years and 5 months following surgery, the patient has recovered without hernia recurrence or other complications. We consider this to be the first case of repair using Composix mesh prosthesis for repair of an atypical and distinctive incisional hernia after an antethoracic pedicled jejunal flap reconstruction. This method seems to be useful and could potentially be widely adopted as the surgical treatment for this condition.

  7. An affinity pull-down approach to identify the plant cyclic nucleotide interactome

    KAUST Repository

    Donaldson, Lara Elizabeth; Meier, Stuart Kurt

    2013-01-01

    Cyclic nucleotides (CNs) are intracellular second messengers that play an important role in mediating physiological responses to environmental and developmental signals, in species ranging from bacteria to humans. In response to these signals, CNs are synthesized by nucleotidyl cyclases and then act by binding to and altering the activity of downstream target proteins known as cyclic nucleotide-binding proteins (CNBPs). A number of CNBPs have been identified across kingdoms including transcription factors, protein kinases, phosphodiesterases, and channels, all of which harbor conserved CN-binding domains. In plants however, few CNBPs have been identified as homology searches fail to return plant sequences with significant matches to known CNBPs. Recently, affinity pull-down techniques have been successfully used to identify CNBPs in animals and have provided new insights into CN signaling. The application of these techniques to plants has not yet been extensively explored and offers an alternative approach toward the unbiased discovery of novel CNBP candidates in plants. Here, an affinity pull-down technique for the identification of the plant CN interactome is presented. In summary, the method involves an extraction of plant proteins which is incubated with a CN-bait, followed by a series of increasingly stringent elutions that eliminates proteins in a sequential manner according to their affinity to the bait. The eluted and bait-bound proteins are separated by one-dimensional gel electrophoresis, excised, and digested with trypsin after which the resultant peptides are identified by mass spectrometry - techniques that are commonplace in proteomics experiments. The discovery of plant CNBPs promises to provide valuable insight into the mechanism of CN signal transduction in plants. © Springer Science+Business Media New York 2013.

  8. An affinity pull-down approach to identify the plant cyclic nucleotide interactome

    KAUST Repository

    Donaldson, Lara Elizabeth

    2013-09-03

    Cyclic nucleotides (CNs) are intracellular second messengers that play an important role in mediating physiological responses to environmental and developmental signals, in species ranging from bacteria to humans. In response to these signals, CNs are synthesized by nucleotidyl cyclases and then act by binding to and altering the activity of downstream target proteins known as cyclic nucleotide-binding proteins (CNBPs). A number of CNBPs have been identified across kingdoms including transcription factors, protein kinases, phosphodiesterases, and channels, all of which harbor conserved CN-binding domains. In plants however, few CNBPs have been identified as homology searches fail to return plant sequences with significant matches to known CNBPs. Recently, affinity pull-down techniques have been successfully used to identify CNBPs in animals and have provided new insights into CN signaling. The application of these techniques to plants has not yet been extensively explored and offers an alternative approach toward the unbiased discovery of novel CNBP candidates in plants. Here, an affinity pull-down technique for the identification of the plant CN interactome is presented. In summary, the method involves an extraction of plant proteins which is incubated with a CN-bait, followed by a series of increasingly stringent elutions that eliminates proteins in a sequential manner according to their affinity to the bait. The eluted and bait-bound proteins are separated by one-dimensional gel electrophoresis, excised, and digested with trypsin after which the resultant peptides are identified by mass spectrometry - techniques that are commonplace in proteomics experiments. The discovery of plant CNBPs promises to provide valuable insight into the mechanism of CN signal transduction in plants. © Springer Science+Business Media New York 2013.

  9. Binding Assays Using Recombinant SH2 Domains: Far-Western, Pull-Down, and Fluorescence Polarization.

    Science.gov (United States)

    Machida, Kazuya; Liu, Bernard

    2017-01-01

    Recognition of phosphotyrosine-containing sequences by SH2 domains confers specificity in tyrosine kinase pathways. By assessing interactions between isolated SH2 domains and their binding proteins, it is possible to gain insight into otherwise inaccessible complex cellular systems. Far-Western, pull-down, and fluorescence polarization (FP) have been frequently used for characterization of phosphotyrosine signaling. Here, we outline standard protocols for these established assays using recombinant SH2 domain, emphasizing the importance of appropriate sample preparation and assay controls.

  10. Evaporation induced diameter control in fiber crystal growth by micro-pulling-down technique: Bi{sub 4}Ge{sub 3}O{sub 12}

    Energy Technology Data Exchange (ETDEWEB)

    Chani, V.; Lebbou, K.; Hautefeuille, B.; Tillement, O. [Physical Chemistry of Luminescent Materials, Claude Bernard Lyon1 University, CNRS UMR 5620, Bat. A. Kastler, 10 rue Ampere, 69622 Villeurbanne Cedex (France); Fourmigue, J.M. [FiberCryst, 23 rue Royale, F-69001 Lyon (France)

    2006-10-15

    Diameter self-control was established in Bi{sub 4}Ge{sub 3}O{sub 12} fiber crystal growth by micro-pulling-down technique. In accordance with Bi{sub 2}O{sub 3}-GeO{sub 2} phase diagram, the diameter was controlled due to compensation of solidification with evaporation of volatile Bi{sub 2}O{sub 3} self-flux charged into the crucible with excess. The crucibles had capillary channels of 310 or 650 {mu}m in outer diameter. The crystals up to 400 mm long and 50-300 {mu}m in diameter were grown at pulling-down rates of 0.04-1.00 mm/min. The melt composition and the pulling rate were generally only two parameters determining solidification rate. As a result, crystals with uniform ({+-} 10%) diameter and aspect ratio up to 10{sup 4} were produced without automation of the process. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Contralateral lumbo-umbilical flap: A versatile technique for volar finger coverage

    Directory of Open Access Journals (Sweden)

    Akram Hussain Bijli

    2017-01-01

    Full Text Available Background: While contemplating any difficult soft tissue reconstruction, patient comfort and compliance is of paramount importance. Reconstruction of the volar aspect of fingers and hand by the ipsilateral pedicled flaps (groin flap, abdominal flaps is demanding as the flap inset is difficult for the surgeon and very uncomfortable for the patient. This often leads to flap complications. For the comfort of the patient, better compliance and ease of complete inset, we planned to manage soft tissue defects of the volar aspect of fingers and hand by a new contralateral pedicled lumbo-umbilical flap. This flap is based on the paraumbilical perforators of deep inferior epigastric artery. Materials and Methods: The contralateral pedicled lumbo-umbilical flap was used in eight patients with high-tension electrical burn injuries involving the volar aspect of fingers and hand. The patients were closely observed for first 6 weeks for any flap or donor site complications and then followed monthly to assess donor and recipient site characteristics for 6 months to 2 years. Results and Conclusion: Large flaps up to 8 cm × 16 cm were raised. All but one flaps survived completely. All patients were mobilised within 48 h and five were discharged in less than a week after initial inset. The flap is reliable, easy to harvest and easy to inset on the volar aspect of fingers. The arm is positioned in a very comfortable position. The main disadvantage, however, is a conspicuous abdominal scar.

  12. A TRAM flap design refinement for use in delayed breast reconstruction.

    LENUS (Irish Health Repository)

    Patel, A J K

    2009-09-01

    Autologous breast reconstruction following mastectomy is commonly achieved using the free Transverse Rectus Abdominis Myocutaneous (TRAM) flap. Since its first description, refinements and modifications have resulted in improved operative techniques and more aesthetically pleasing reconstructions. Pre-operative flap design, however, is a relatively new concept that has not received much attention in the literature. Patients who undergo breast reconstruction may have large, ptotic contralateral breasts. In these patients there is a tendency to raise a large abdominal flap in an attempt to achieve symmetry, or simply a larger breast. This has the potential to lead to tight closure of the abdomen and the risk of subsequent wound problems. Reconstructions that are too small or have inadequate ptosis commit the patient to contralateral breast surgery to achieve symmetry. Pre-operatively designing the flap, using a template created from the opposite breast, can help achieve a good match, often reducing the need for contralateral breast surgery. Even when contralateral breast reduction surgery is planned in advance, many of these patients still require, and prefer, a large reconstruction in order to achieve a well-proportioned result. We present a design template that addresses these particular issues and in the senior author\\'s hands has proved to be a very effective technique. Our technique allows raising an abdominal flap of less vertical height than traditionally used (thus reducing the risk of tight abdominal closure) and incorporates an inverted V-shaped flap of skin from the inferior mastectomy skin flap into the reconstruction. This allows more flap tissue to be available to fill the upper poles of the reconstructed breast and at the same time produces good ptosis.

  13. A Rare Case of Giant Basal Cell Carcinoma of the Abdominal Wall: Excision and Immediate Reconstruction with a Pedicled Deep Inferior Epigastric Artery Perforator (DIEP) Flap.

    Science.gov (United States)

    Di Lorenzo, Sara; Zabbia, Giovanni; Corradino, Bartolo; Tripoli, Massimiliano; Pirrello, Roberto; Cordova, Adriana

    2017-12-04

    BACKGROUND Basal cell carcinoma (BCC) greater than 5 cm in diameter is called giant basal cell carcinoma (GBCC), or super giant basal cell carcinoma if it has a diameter larger than 20 cm. Giant BCC only accounts for 0.5% of BCCs and super giant BCC is exceedingly rare. On account of their rarity, there are no established guidelines for GBCC treatment. CASE REPORT We describe a peculiar case of an 82-year-old woman with a GBCC carcinoma of the lower abdominal wall. The tumor was surgically removed with ipsilateral inguinal lymph nodes and the abdominal wall was reconstructed immediately with a pedicled deep inferior epigastric artery perforator (DIEP) flap. CONCLUSIONS Treatment of giant basal cell carcinoma is often difficult, especially in elderly patients with poor general health and multiple pathologies. The pedicled DIEP flap is rotated to cover the loss of substance without tension, and it is easy to harvest and transfer. This flap allowed a good result without local or systemic complication. We present this report as a reminder of the occasional occurrence of extremely aggressive BCCs. We believe that, especially for rare tumors like these, it is very useful for the entire scientific community to publish these cases and the therapeutic strategies used to treat them.

  14. The rare sugar D-allose has a reducing effect against ischemia-reperfusion injury on the rat abdominal skin island flap model.

    Science.gov (United States)

    Muneuchi, Gan; Hossain, Akram; Yamaguchi, Fuminori; Ueno, Masaki; Tanaka, Yoshio; Suzuki, Shigehiko; Tokuda, Masaaki

    2013-08-01

    Recently, one of the rare sugars, D-allose, has received attention from many researchers because of its availability for mass production and its various physiological functions. Among these, an antioxidative effect has been strongly suggested. In this study, we investigated whether this effect is also applicable to the field of skin surgery. In ischemia-reperfusion injury model using the rat abdominal skin island flap (male Wistar rats, n = 110), D-allose was injected intravenously 15 min before 8-h ischemia. The survival area (%) was measured by digital photographic assessment 1 wk after surgery, and multiple comparisons (Fisher's protected least significant difference) were carried out. Histopathological examination (neutrophilic infiltration into dermis in hematoxylin and eosin stain) and immunostaining (of ectodermal dysplasia-1 (ED1)-positive cells/flap) were assessed. Myeloperoxidase (MPO) activity in the skin flap (sampling at the time of 8 h after reperfusion) was measured spectrophotometrically, and Student t-test was performed. D-allose extended the survival of the remaining flaps, and a dose greater than 30 mg (0.1 mg/g) was necessary to be effective. The flap survival rates in the 30, 60, and 150 mg groups were significantly higher than that in the control (saline) group: 75.87 ± 5.90, 79.27 ± 7.81, and 77.87 ± 6.20 versus 50.53 ± 9.66, respectively (P rare sugars are safer for our bodies as well as the environment; therefore, this rare sugar project is expected to lead to the development of a safer antioxidant for skin flap surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. A case of intractable gastrocutaneous fistula after gastric pull-up reconstruction of the pharynx and esophagus

    International Nuclear Information System (INIS)

    Wada, Tadahiko; Tanaka, Shinzo; Hiratsuka, Yasuyuki; Kumabe, Yohei; Yamahara, Kohei; Koyama, Taiji

    2012-01-01

    Pharyngocutaneous or esophagocutaneous fistula formation is not a rare complication after surgical treatment of head/neck cancer. In cases having developed such fistula, conservative treatment with local manipulation or surgical closure of the fistula using a local or pedicled flap is often possible. We recently encountered a case with an intractable gastrocutaneous fistula which occurred a long time after gastric pull-up reconstruction of the pharynx and esophagus. The patient was a 58-year-old female. As treatment for hypopharyngeal and thoracic esophageal cancers, the patient underwent total resections of the laryngopharynx and esophagus and gastric pull-up reconstruction of the esophagus. Postoperatively, 50 Gy radiation was applied to the neck. Although there was no recurrence of cancer, a salivary fistula above the tracheostomy occurred six years after surgery. Closure of the fistula with a local flap was attempted twice, but did not succeed. The fistula was then closed with a deltopectoral (DP) flap, but a fistula recurred five months later. Finally, by resecting the cervical segment of the pulled-up stomach, the esophagus was reconstructed successfully with a free jejunal graft. An intractable fistula should be replaced using tissue with rich blood flow, such as a free jejunal graft. (author)

  16. Preoperative TRAM free flap volume estimation for breast reconstruction in lean patients.

    Science.gov (United States)

    Minn, Kyung Won; Hong, Ki Yong; Lee, Sang Woo

    2010-04-01

    To obtain pleasing symmetry in breast reconstruction with transverse rectus abdominis myocutaneous (TRAM) free flap, a large amount of abdominal flap is elevated and remnant tissue is trimmed in most cases. However, elevation of abundant abdominal flap can cause excessive tension in donor site closure and increase the possibility of hypertrophic scarring especially in lean patients. The TRAM flap was divided into 4 zones in routine manner; the depth and dimension of the 4 zones were obtained using ultrasound and AutoCAD (Autodesk Inc., San Rafael, CA), respectively. The acquired numbers were then multiplied to obtain an estimate of volume of each zone and the each zone volume was added. To confirm the relation between the estimated volume and the actual volume, authors compared intraoperative actual TRAM flap volumes with preoperative estimated volumes in 30 consecutive TRAM free flap breast reconstructions. The estimated volumes and the actual elevated volumes of flap were found to be correlated by regression analysis (r = 0.9258, P Autodesk Inc.) allow the authors to attain the precise volume desired for elevation. This method provides advantages in terms of minimal flap trimming, easier closure of donor sites, reduced scar widening and symmetry, especially in lean patients.

  17. A role of abdomen in butterfly's flapping flight

    Science.gov (United States)

    Jayakumar, Jeeva; Senda, Kei; Yokoyama, Naoto

    2017-11-01

    Butterfly's forward flight with periodic flapping motion is longitudinally unstable, and control of the thoracic pitching angle is essential to stabilize the flight. This study aims to comprehend roles which the abdominal motion play in the pitching stability of butterfly's flapping flight by using a two-dimensional model. The control of the thoracic pitching angle by the abdominal motion is an underactuated problem because of the limit on the abdominal angle. The control input of the thorax-abdomen joint torque is obtained by the hierarchical sliding mode control in this study. Numerical simulations reveal that the control by the abdominal motion provides short-term pitching stabilization in the butterfly's flight. Moreover, the control input due to a large thorax-abdomen joint torque can counteract a quite large perturbation, and can return the pitching attitude to the periodic trajectory with a short recovery time. These observations are consistent with biologists' view that living butterflies use their abdomens as rudders. On the other hand, the abdominal control mostly fails in long-term pitching stabilization, because it cannot directly alter the aerodynamic forces. The control for the long-term pitching stabilization will also be discussed.

  18. White Roll Vermilion turn down flap in primary unilateral cleft lip repair: A novel approach

    Directory of Open Access Journals (Sweden)

    R K Mishra

    2015-01-01

    Full Text Available Aim: Numerous modifications of Millard′s technique of rotation - advancement repair have been described in literature. This article envisions a new modification in Millard′s technique of primary unilateral chieloplasty. Material and Methods: Eliminating or reducing the secondary deformities in children with cleft lip has been a motivating factor for the continual refinement of cleft lip surgical techniques through the years. Vermilion notching, visibility of paramedian scars and scar contracture along the white roll are quite noticeable in close-up view even in good repairs. Any scar is less noticeable if it is in midline or along the lines of embryological closure. White Roll Vermilion turn down Flap (WRV Flap, a modification in the Millard′s repair is an attempt to prevent these secondary deformities during the primary cleft lip sugery. This entails the use of white roll and the vermilion from the lateral lip segment for augmenting the medial lip vermilion with the final scar in midline at the vermilion. Result: With an experience of more than 100 cases of primary cleft lip repair with this technique, we have achieved a good symmetry and peaking of cupid′s bow with no vermilion notching of the lips. Conclusion: WRV flap aims to high light the importance of achieving a near normal look of the cleft patient with the only drawback of associated learning curve with this technique.

  19. Growth and luminescence properties of Eu:SrI.sub.2./sub. single crystals prepared by modified micro-pulling-down method

    Czech Academy of Sciences Publication Activity Database

    Král, Robert; Jarý, Vítězslav; Pejchal, Jan; Kurosawa, S.; Nitsch, Karel; Yokota, Y.; Nikl, Martin; Yoshikawa, A.

    2016-01-01

    Roč. 63, č. 2 (2016), s. 453-458 ISSN 0018-9499 R&D Projects: GA MŠk(CZ) LH14266 Institutional support: RVO:68378271 Keywords : Eu 2+ and Eu 3+ doping * crystal growth * luminescence * micro-pulling-down method * strontium iodide Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.171, year: 2016

  20. Bilateral simultaneous breast reconstruction with SGAP flaps.

    Science.gov (United States)

    Flores, Jaime I; Magarakis, Michael; Venkat, Raghunandan; Shridharani, Sachin M; Rosson, Gedge D

    2012-07-01

    Two work-horse approaches to postmastectomy breast reconstruction are the deep inferior epigastric perforator flap and the superior gluteal artery perforator (SGAP) flap [and its variation, the lateral septocutaneous superior gluteal artery perforator flap]. Our purpose was fourfold: 1) to analyze our experience with the SGAP flaps for simultaneous bilateral breast reconstruction; 2) to analyze our experience with lateral septocutaneous superior gluteal artery perforator flaps for that procedure; 3) to compare our results with those in the literature; and 4) to highlight the importance of preoperative three-dimensional computed tomographic angiography. A retrospective chart review was completed for 23 patients who underwent breast reconstruction between December 2005 and January 2010 via an SGAP flap (46 flaps). We reviewed flap weight, ischemia time, length of stay, overall flap survival, fat necrosis development, and emergency re-exploration. Mean weights were 571.2 ± 222.0 g (range 186-1,117 g) and 568.0 ± 237.5 g (range 209-1,115 g) for the left and right buttock flap, respectively. Mean ischemia time was 129.1 ± 15.7 and 177.7 ± 24.7 minutes for the first and second flap, respectively. Mean hospital stay was 5.3 ± 2.5 days. All flaps survived. Fat necrosis developed in five flaps (10.8%), and emergency re-exploration was required in three patients (three flaps). When harvesting abdominal tissue is a poor option, the SGAP flap is an efficacious procedure for patients desiring autologous breast reconstruction, and bilateral procedures can be performed simultaneously. Copyright © 2012 Wiley Periodicals, Inc.

  1. Identification of RNAIII-binding proteins in Staphylococcus aureus using tethered RNAs and streptavidin aptamers based pull-down assay.

    Science.gov (United States)

    Zhang, Xu; Zhu, Qing; Tian, Tian; Zhao, Changlong; Zang, Jianye; Xue, Ting; Sun, Baolin

    2015-05-15

    It has been widely recognized that small RNAs (sRNAs) play important roles in physiology and virulence control in bacteria. In Staphylococcus aureus, many sRNAs have been identified and some of them have been functionally studied. Since it is difficult to identify RNA-binding proteins (RBPs), very little has been known about the RBPs in S. aureus, especially those associated with sRNAs. Here we adopted a tRNA scaffold streptavidin aptamer based pull-down assay to identify RBPs in S. aureus. The tethered RNA was successfully captured by the streptavidin magnetic beads, and proteins binding to RNAIII were isolated and analyzed by mass spectrometry. We have identified 81 proteins, and expressed heterologously 9 of them in Escherichia coli. The binding ability of the recombinant proteins with RNAIII was further analyzed by electrophoresis mobility shift assay, and the result indicates that proteins CshA, RNase J2, Era, Hu, WalR, Pyk, and FtsZ can bind to RNAIII. This study suggests that some proteins can bind to RNA III in S. aureus, and may be involved in RNA III function. And tRSA based pull-down assay is an effective method to search for RBPs in bacteria, which should facilitate the identification and functional study of RBPs in diverse bacterial species.

  2. Bilateral Free Flap Breast Reconstruction Outcomes: Do Abdominal Scars Affect Bilateral Flaps?

    Directory of Open Access Journals (Sweden)

    Dmytro Unukovych, MD, PhD

    2017-09-01

    Conclusion:. Surgical outcomes of bilateral reconstructions in patients with abdominal scars are generally comparable with ones in patients without prior surgery; however, some problems have been identified. These procedures might have some intraoperative considerations and often require increased operative times. Apart from the traditional preoperative computed tomography angiography, intraoperative imaging (e.g., fluorescence angiography may be advocated in patients with abdominal scars.

  3. Reconstruction of the pelvic floor and the vagina after total pelvic exenteration using the transverse musculocutaneous gracilis flap.

    Science.gov (United States)

    Kaartinen, Ilkka S; Vuento, Maarit H; Hyöty, Marja K; Kallio, Jukka; Kuokkanen, Hannu O

    2015-01-01

    Total pelvic exenteration (TPE) is a rare operation in which the pelvic contents are removed entirely. Several options for pelvic floor and vaginal reconstruction have been described including transverse rectus abdominis musculocutaneous (TRAM) or deep inferior epigastric perforator (DIEP) flaps. The transverse musculocutaneous gracilis (TMG) flap has been introduced for breast reconstruction as a free flap. We adopted the pedicled TMG flap for reconstructions after TPE. To the best of our knowledge, this is the first report of this method in the literature. Between November 2011 and February 2014, 12 patients underwent TPE and reconstruction with unilateral (six patients) or bilateral (six patients) pedicled TMG flaps. Five patients underwent vaginal reconstruction with bilateral TMG flaps. We describe the operative procedure and the outcome of the operation in these patients. The total mean operative times for TPE with or without vaginal reconstruction were 467 ± 12 and 386 ± 59 min, respectively. The TMG flaps had enough vascular tissue and mobility for reconstructing the TPE defects. There was distal edge necrosis in one out of 18 flaps, while the rest survived completely. During the follow-up, complete wound healing with no signs of weakening of the pelvic floor was observed in all cases. Soft-tissue reconstructions are needed to reduce complications associated with TPE, to secure the pelvic floor and to reconstruct the vagina in select patients. The TMG flap is a logical flap choice that does not lead to functional deficits, complicate the abdominal ostomies or weaken the abdominal wall. It reduces the length of operation compared to that of abdominal flaps. IV, therapeutic. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Modifications of micro-pulling-down method for the growth of selected Li-containing crystals for neutron scintillator and VUV scintillation crystals

    Czech Academy of Sciences Publication Activity Database

    Pejchal, Jan; Fujimoto, Y.; Chani, V.; Yanagida, T.; Yokota, Y.; Yoshikawa, A.; Nikl, Martin; Beitlerová, Alena

    2012-01-01

    Roč. 360, SI (2012), 127–130 ISSN 0022-0248 R&D Projects: GA MŠk(CZ) 1M06002 Grant - others:AVČR(CZ) M100100910 Institutional research plan: CEZ:AV0Z10100521 Keywords : Ti-doping * micro-pulling-down * barium lutetium fluoride * lithium aluminate * neutron scintillator Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.552, year: 2012

  5. Jet-Like Flow and Thrust From a Flexible Flapping Foil in Stationary Fluid

    Science.gov (United States)

    2009-12-29

    considered as a movable hinge point which travels over the flap region resulting in differential flap portions, pulling and pushing the fluid about this 15...Fliegenflugel und Hypothesen uber zugeordnete instationare Stromungseffekte,” J. Comp. Physiol., vol. 133, pp. 351–355, 1979. [24] Rayner, J. M. V., “A vortex...ring by giving an impulse to a circular disk and then dissolving it away,” J. App. Phys., vol. 24, no. 1, pp. 104, 1953. 17 [28] Wagner H., “ Uber die

  6. Immediate Bilateral Breast Reconstruction with Unilateral Deep Superior Epigastric Artery and Superficial Circumflex Iliac Artery Flaps

    Directory of Open Access Journals (Sweden)

    Keith S. Hansen

    2016-09-01

    Full Text Available Autologous breast reconstruction utilizing a perforator flap is an increasingly popular method for reducing donor site morbidity and implant-related complications. However, aberrant anatomy not readily visible on computed tomography angiography is a rare albeit real risk when undergoing perforator flap reconstruction. We present an operative case of a patient who successfully underwent a bilateral breast reconstruction sourced from a unilateral abdominal flap divided into deep superior epigastric artery and superficial circumflex iliac artery flap segments.

  7. THORACO - ABDOMINAL FLAP FOR RESURFACING LARGE POST MASTECTOMY DEFECTS IN LOCALLY ADVANCED CA. BREAST

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao

    2015-02-01

    Full Text Available Covering of large wounds after mastectomy in locally advanced Ca breast with skin that can withstand radiotherapy is a challenge to the surgeon. Here this study we used a local advancement flap from the adjacent area called Thoraco - A bdominal F la p (TA flap for such giant defects. This is based on superficial and lumbar arteries and is thick to with stand consequent RT . MATERIALS AND METHODS: Of the total 107 cases of LABC 32 had post mastectomy defects of larger than 12 cm and could not be closed by simple approximation. Among the 32 cases 17 cases are covered by split thickness skin grafting. 15 cases are covered by TA flap. These cases are assessed for mean operating time, mean blood loss, post - operative stay, flap necrosis and viability of the f lap after radiotherapy. RESULTS: There is minimal extra time or blood loss in these cases . All the flaps healed well except for small edge necrosis in 4 cases. In all the patients we could start radiotherapy in the fourth week of surgery and all the flaps withstood RT well. After further evaluation probably this can be recommended as procedure for giant post mastectomy defects particularly for those who require RT early

  8. [Pedicled versus free TRAM flap for breast reconstruction].

    Science.gov (United States)

    Galla, T J; Lukas, B; Feller, A M

    1999-03-01

    In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.

  9. [The influence of estradiol on histomorphology of skin flaps with ischemia reperfusion injury].

    Science.gov (United States)

    Jianlong, Wu; Ruixing, Hou; Guangliang, Zhou; Jihui, Ju

    2015-09-01

    To study the influence of estradiol on histomorphology of skin flaps with ischemia reperfusion injury. 48 adult male Wistar rats aged 12-14 weeks old, were randomly divided into control group (group I), ischemia-reperfusion group (group II), saline group (group III), estradiol group (group IV). Superficial epigastric artery axial flap, 3 cm x 6 cm in size, was made in the left lower quadrant abdominal of each rat. Flap model with ischemia-reperfusion injury was established by using the nondestructive micro vascular clamp to clamp the superficial epigastric artery. The general condition of the flap was observed after operation. At 7 days after operation, the survival rate of the flap was detected, the flaps were harvested to receive histology and ultrastructural observation. The neutrophils level of the superficial epigastric vein were tested. 7 days after operation, the survival rate of the flap in group IV was significantly higher than that in group II, III (P organization structure in flap.

  10. Management of postirradiation recurrent enterocutaneous fistula by muscle flaps

    Energy Technology Data Exchange (ETDEWEB)

    Lui, R.C.; Friedman, R.; Fleischer, A.

    1989-07-01

    Occasionally surgeons have to operate on patients who have had previous abdominal or pelvic operations and irradiations for malignancies. Bowel resection with primary anastomosis under these circumstances is fraught with major complications such as anastomotic breakdown with intra-abdominal sepsis or recurrent enterocutaneous fistula, which are refractory to conventional management. New techniques for using vascularized muscle flaps from a distant nonirradiated field to achieve safe repair of the bowel defects in three such instances are presented.

  11. Infection of PTFE mesh 15 years following pedicled TRAM flap breast reconstruction: mechanism and aetiology.

    Science.gov (United States)

    Elfaki, A; Gkorila, A; Khatib, M; Malata, C M

    2018-01-01

    The pedicled transverse rectus abdominis myocutaneous (TRAM) flap procedure is still widely used for breast reconstruction. The repair of the flap harvest site in the transverse rectus abdominis muscle and sheath is often assisted by the use of prosthetic meshes. This decreases the risk of abdominal wall weakness and herniation but, being a foreign body, it also carries the risk of infection. In this report, we describe the case of a 63-year-old patient who, whilst receiving chemotherapy for metastatic breast cancer, presented with an infected polytetrafluoroethylene mesh 15 years after pedicled TRAM flap immediate breast reconstruction. This necessitated mesh removal to treat the infection. Following a thorough review of the English literature, this is the longest recorded presentation of an abdominal prosthetic mesh infection. The mechanism and aetiology of such a late complication are discussed.

  12. Three-dimensional computed tomographic angiography to predict weight and volume of deep inferior epigastric artery perforator flap for breast reconstruction.

    Science.gov (United States)

    Rosson, Gedge D; Shridharani, Sachin M; Magarakis, Michael; Manahan, Michele A; Stapleton, Sahael M; Gilson, Marta M; Flores, Jaime I; Basdag, Basak; Fishman, Elliot K

    2011-10-01

    Three-dimensional computed tomographic angiography (3D CTA) can be used preoperatively to evaluate the course and caliber of perforating blood vessels for abdominal free-flap breast reconstruction. For postmastectomy breast reconstruction, many women inquire whether the abdominal tissue volume will match that of the breast to be removed. Therefore, our goal was to estimate preoperative volume and weight of the proposed flap and compare them with the actual volume and weight to determine if diagnostic imaging can accurately identify the amount of tissue that could potentially to be harvested. Preoperative 3D CTA was performed in 15 patients, who underwent breast reconstruction using the deep inferior epigastric artery perforator flap. Before each angiogram, stereotactic fiducials were placed on the planned flap outline. The radiologist reviewed each preoperative angiogram to estimate the volume, and thus, weight of the flap. These estimated weights were compared with the actual intraoperative weights. The average estimated weight was 99.7% of the actual weight. The interquartile range (25th to 75th percentile), which represents the "middle half" of the patients, was 91-109%, indicating that half of the patients had an estimated weight within 9% of the actual weight; however, there was a large range (70-133%). 3D CTA with stereotactic fiducials allows surgeons to adequately estimate abdominal flap volume before surgery, potentially giving guidance in the amount of tissue that can be harvested from a patient's lower abdomen. Copyright © 2011 Wiley-Liss, Inc.

  13. Bridge flap technique as a single-step solution to mucogingival problems: A case series

    Directory of Open Access Journals (Sweden)

    Vivek Gupta

    2011-01-01

    Full Text Available Shallow vestibule, gingival recession, inadequate width of attached gingiva (AG and aberrant frenum pull are an array of mucogingival problems for which several independent and effective surgical solutions are reported in the literature. This case series reports the effectiveness of the bridge flap technique as a single-step surgical entity for increasing the depth of the vestibule, root coverage, increasing the width of the AG and solving the problem of abnormal frenum pull. Eight patients with 18 teeth altogether having Millers class I, II or III recession along with problems of shallow vestibule, inadequate width of AG and with or without frenum pull underwent this surgical procedure and were followed-up till 9 months post-operatively. The mean root coverage obtained was 55% and the mean average gain in width of the AG was 3.5 mm. The mean percentage gain in clinical attachment level was 41%. The bridge flap technique can be an effective single-step solution for the aforementioned mucogingival problems if present simultaneously in any case, and offers considerable advantages over other mucogingival surgical techniques in terms of simplicity, limited chair-time for the patient and the operator, single surgical intervention for manifold mucogingival problems and low morbidity because of the absence of palatal donor tissue.

  14. Diode-pumped laser with Yb:YAG single-crystal fiber grown by the micro-pulling down technique

    Science.gov (United States)

    Sangla, D.; Aubry, N.; Didierjean, J.; Perrodin, D.; Balembois, F.; Lebbou, K.; Brenier, A.; Georges, P.; Tillement, O.; Fourmigué, J.-M.

    2009-02-01

    Laser emission obtained from an Yb:YAG single-crystal fiber directly grown by the micro-pulling down technique is demonstrated for the first time. We achieved 11.2 W of continuous wave (CW) output power at 1031 nm for 55 W of incident pump power at 940 nm. In the Q-switched regime, we obtained pulses as short as 17 ns, for an average power of 2.3 W at 2 kHz corresponding to an energy of 1.15 mJ. In both cases, the M 2 factor was 2.5. This single-crystal fiber showed performance similar to a standard rod elaborated by the Czochralski method. The potential of Yb3+-doped single-crystal fibers is presented for scalable high-average and high-peak-power laser systems.

  15. Growth of Bi 12SiO 20 single crystals by the pulling-down method with continuous feeding

    Science.gov (United States)

    Maida, Shigeru; Higuchi, Mikio; Kodaira, Kohei

    1999-09-01

    Bi 12SiO 20 single crystals were successfully grown by the pulling-down method with continuous feeding. As-grown crystals were amber in color and transparent, and had no cracks or inclusions. A crystal with homogeneous composition was obtained from Bi-rich feed powder having a composition of 14.1 mol% SiO 2, whereas precipitates of Bi 4Si 3O 12 were observed on the surface of a crystal grown with stoichiometric powder. The shape of the solid-liquid interface during the crystal growth was estimated to be almost flat, which was favorable to avoid core formation. Average dislocation density was 4×10 3/cm 2, which was comparable to that of Bi 12SiO 20 crystals grown by the Czochralski method.

  16. Desferrioxamine: a practical method for improving neovascularization of prefabricated flaps.

    Science.gov (United States)

    Li, Bin; Li, Hua; Jin, Rui; Cheng, Chen; Wang, Jing; Zhu, Hainan; Zan, Tao; Li, Qingfeng; Hao, Lijun

    2015-02-01

    Prefabricated flaps are an ideal alternative to repair massive and complex tissue defects. Nevertheless, the risk of necrosis due to unpredictable blood supplies is a major obstacle to the application of prefabricated flaps. The survival of a prefabricated flap depends on the neovascularization between the vascular carrier and the donor tissue. Here, we proposed that the iron chelator, desferrioxamine (DFX), owned therapeutic effects that promoted the neovascularization of prefabricated flaps. An abdominal prefabricated flap model was created in rats via a 2-stage operation. The rats were allocated into 4 groups as follows: 2 groups of rats received DFX treatments during the first or the second stage of the operation, respectively; 1 group of rats received a delay procedure 1 week before the second operation; and the final group was used as a blank control. Flap survival rates and capillary densities were evaluated between groups. The influence of DFX on the dermal fibroblasts was also studied in vitro. Desferrioxamine treatment during the first stage of the operation greatly increased flap survival rate compared to the blank control. The results were similar to those produced by the delay treatment. The vessel count results were consistent with the flap survival rate findings. In vitro, DFX treatment up-regulated the expression levels of several angiogenic factors in the dermal fibroblasts. Nevertheless, DFX treatment during the second stage of the operation was therapeutically detrimental. The application of DFX around the time of vascular carrier implantation greatly promoted neovascularization of prefabricated flaps, but was therapeutically detrimental after the flaps had been elevated.

  17. Argonaute pull-down and RISC analysis using 2'-O-methylated oligonucleotides affinity matrices.

    Science.gov (United States)

    Jannot, Guillaume; Vasquez-Rifo, Alejandro; Simard, Martin J

    2011-01-01

    During the last decade, several novel small non-coding RNA pathways have been unveiled, which reach out to many biological processes. Common to all these pathways is the binding of a small RNA molecule to a protein member of the Argonaute family, which forms a minimal core complex called the RNA-induced silencing complex or RISC. The RISC targets mRNAs in a sequence-specific manner, either to induce mRNA cleavage through the intrinsic activity of the Argonaute protein or to abrogate protein synthesis by a mechanism that is still under investigation. We describe here, in details, a method for the affinity chromatography of the let-7 RISC starting from extracts of the nematode Caenorhabditis elegans. Our method exploits the sequence specificity of the RISC and makes use of biotinylated and 2'-O-methylated oligonucleotides to trap and pull-down small RNAs and their associated proteins. Importantly, this technique may easily be adapted to target other small RNAs expressed in different cell types or model organisms. This method provides a useful strategy to identify the proteins associated with the RISC, and hence gain insight in the functions of small RNAs.

  18. Study of Flapping Flight Using Discrete Vortex Method Based Simulations

    Science.gov (United States)

    Devranjan, S.; Jalikop, Shreyas V.; Sreenivas, K. R.

    2013-12-01

    In recent times, research in the area of flapping flight has attracted renewed interest with an endeavor to use this mechanism in Micro Air vehicles (MAVs). For a sustained and high-endurance flight, having larger payload carrying capacity we need to identify a simple and efficient flapping-kinematics. In this paper, we have used flow visualizations and Discrete Vortex Method (DVM) based simulations for the study of flapping flight. Our results highlight that simple flapping kinematics with down-stroke period (tD) shorter than the upstroke period (tU) would produce a sustained lift. We have identified optimal asymmetry ratio (Ar = tD/tU), for which flapping-wings will produce maximum lift and find that introducing optimal wing flexibility will further enhances the lift.

  19. Fingertip reconstruction with simultaneous flaps and nail bed grafts following amputation.

    Science.gov (United States)

    Hwang, Euna; Park, Byung Ho; Song, Seung Yong; Jung, Ho Sung; Kim, Chung Hun

    2013-07-01

    To report our technique and results with treating fingertip amputations with flaps and simultaneous nailbed grafts. We reconstructed 20 fingertip amputations with loss of bone and nail with flaps combined with nailbed grafts. We reconstructed the volar side of the fingertip with a flap, and the dorsal side of the fingertip with a nailbed grafted to the raw inner surface of the flap. We employed volar V-Y advancement flaps for transverse or dorsal oblique fingertip injuries and generally used abdominal flaps for volar oblique fingertip injuries. We harvested nailbeds from the amputated finger or from the patient's first toe. The length of the amputated fingertips was restored with the flaps, and the lost nailbeds were restored to their natural appearance with the nailbed grafts. We classified the results according to the length of the reconstructed fingertip and the appearance of the nail. Excellent or good results were achieved in 16 cases. Three cases had fair results and 1 had a poor result. We observed favorable results for distal fingertip amputations (Allen type II or III). In particular, most cases that were reconstructed with volar V-Y advancement flaps combined with nailbed grafts demonstrated favorable results. This method is useful for the restoration of dorsal oblique or transverse type fingertip amputations and is a good alternative when replantation is not an option. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Diaphragmatic hernia repair using a rectus abdominis muscle pedicle flap in three dogs.

    Science.gov (United States)

    Chantawong, P; Komin, K; Banlunara, W; Kalpravidh, M

    2013-01-01

    To report the clinical use of a pedicle flap from the rectus abdominis muscle to repair extensive diaphragmatic tears in dogs with diaphragmatic hernia. Three dogs with a combination of radial and circumferential diaphragmatic tears were studied. The circumferential tear was repaired by suturing the wound edge with the edge at the abdominal wall. A pedicle flap of the rectus abdominis muscle was used for repairing the radial tear. The dogs were examined radiographically for lung and diaphragm appearance and evidence of reherniation at 10 days, and at one, two, and four months after surgery, and fluoroscopically for paradoxical motion of the diaphragm at one and four months. The rectus abdominis muscle pedicle flap was successfully used in all three dogs. The animals recovered uneventfully without evidence of reherniation during the four follow-up months. Fluoroscopic examination revealed no paradoxical motion of the diaphragm. A rectus abdominis muscle pedicle flap can be used for repairing large diaphragmatic defects in dogs.

  1. Optimization of breast reconstruction results using TMG flap in 30 cases: Evaluation of several refinements addressing flap design, shaping techniques, and reduction of donor site morbidity.

    Science.gov (United States)

    Nickl, Stefanie; Nedomansky, Jakob; Radtke, Christine; Haslik, Werner; Schroegendorfer, Klaus F

    2018-01-31

    The transverse myocutaneous gracilis (TMG) flap is a widely used alternative to abdominal flaps in autologous breast reconstruction. However, secondary procedures for aesthetic refinement are frequently necessary. Herein, we present our experience with an optimized approach in TMG breast reconstruction to enhance aesthetic outcome and to reduce the need for secondary refinements. We retrospectively analyzed 37 immediate or delayed reconstructions with TMG flaps in 34 women, performed between 2009 and 2015. Four patients (5 flaps) constituted the conventional group (non-optimized approach). Thirty patients (32 flaps; modified group) underwent an optimized procedure consisting of modified flap harvesting and shaping techniques and methods utilized to reduce denting after rib resection and to diminish donor site morbidity. Statistically significant fewer secondary procedures (0.6 ± 0.9 versus 4.8 ± 2.2; P < .001) and fewer trips to the OR (0.4 ± 0.7 versus 2.3 ± 1.0 times; P = .001) for aesthetic refinement were needed in the modified group as compared to the conventional group. In the modified group, 4 patients (13.3%) required refinement of the reconstructed breast, 7 patients (23.3%) underwent mastopexy/mammoplasty or lipofilling of the contralateral breast, and 4 patients (13.3%) required refinement of the contralateral thigh. Total flap loss did not occur in any patient. Revision surgery was needed once. Compared to the conventional group, enhanced aesthetic results with consecutive reduction of secondary refinements could be achieved when using our modified flap harvesting and shaping techniques, as well as our methods for reducing contour deformities after rib resection and for overcoming donor site morbidities. © 2017 Wiley Periodicals, Inc.

  2. Directionally solidified Al2O3/GAP eutectic ceramics by micro-pulling-down method

    Science.gov (United States)

    Cao, Xue; Su, Haijun; Guo, Fengwei; Tan, Xi; Cao, Lamei

    2016-11-01

    We reported a novel route to prepare directionally solidified (DS) Al2O3/GAP eutectic ceramics by micro-pulling-down (μ-PD) method. The eutectic crystallizations, microstructure characters and evolutions, and their mechanical properties were investigated in detail. The results showed that the Al2O3/GAP eutectic composites can be successfully fabricated through μ-PD method, possessed smooth surface, full density and large crystal size (the maximal size: φ90 mm × 20 mm). At the process of Diameter, the as-solidified Al2O3/GAP eutectic presented a combination of "Chinese script" and elongated colony microstructure with complex regular structure. Inside the colonies, the rod-type or lamellar-type eutectic microstructures with ultra-fine GAP surrounded by the Al2O3 matrix were observed. At an appropriate solidificational rate, the binary eutectic exhibited a typical DS irregular eutectic structure of "chinese script" consisting of interpenetrating network of α-Al2O3 and GAP phases without any other phases. Therefore, the interphase spacing was refined to 1-2 µm and the irregular microstructure led to an outstanding vickers hardness of 17.04 GPa and fracture toughness of 6.3 MPa × m1/2 at room temperature.

  3. Reverse Abdominoplasty Flap in Reconstruction of Post-Bilateral Mastectomies Anterior Chest Wall Defect

    Directory of Open Access Journals (Sweden)

    William HC Tiong

    2014-01-01

    Full Text Available Reverse abdominoplasty was originally described for epigastric lift. Since the work by Baroudi and Huger in the 1970s, it has become clear that reverse abdominoplasty application can be extended beyond just aesthetic procedure. Through the knowledge of anterior abdominal wall vascularity, its application had included reconstructive prospect in the coverage of various chest wall defects. To date, reverse abdominoplasty flap has been used to reconstruct unilateral anterior chest wall defect or for larger defect but only in combination with other reconstructive techniques. Here, we presented a case where it is used as a standalone flap to reconstruct bilateral anterior chest wall soft tissue defect post-bilateral mastectomies in oncological resection. In conclusion, reverse abdominoplasty flap provided us with a simple, faster, and satisfactory reconstructive outcome.

  4. Pulling cylindrical particles using a soft-nonparaxial tractor beam

    DEFF Research Database (Denmark)

    Novitsky, Andrey; Ding, Weiqiang; Wang, Maoyan

    2017-01-01

    In order to pull objects towards the light source a single tractor beam inevitably needs to be strongly nonparaxial. This stringent requirement makes such a tractor beam somewhat hypothetical. Here we reveal that the cylindrical shape of dielectric particles can effectively mitigate the nonparaxi......In order to pull objects towards the light source a single tractor beam inevitably needs to be strongly nonparaxial. This stringent requirement makes such a tractor beam somewhat hypothetical. Here we reveal that the cylindrical shape of dielectric particles can effectively mitigate...... the nonparaxiality requirements, reducing the incidence angle of the partial plane waves of the light beam down to 45 degrees and even to 30 degrees for respectively dipole and dipole-quadrupole objects. The optical pulling force attributed to the interaction of magnetic dipole and magnetic quadrupole moments...... and sorting of targeted particles....

  5. Measurement of Vehicle Air Conditioning Pull-Down Period

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, John F [ORNL; Huff, Shean P [ORNL; Moore, Larry G [ORNL; West, Brian H [ORNL

    2016-08-01

    Air conditioner usage was characterized for high heat-load summer conditions during short driving trips using a 2009 Ford Explorer and a 2009 Toyota Corolla. Vehicles were parked in the sun with windows closed to allow the cabin to become hot. Experiments were conducted by entering the instrumented vehicles in this heated condition and driving on-road with the windows up and the air conditioning set to maximum cooling, maximum fan speed and the air flow setting to recirculate cabin air rather than pull in outside humid air. The main purpose was to determine the length of time the air conditioner system would remain at or very near maximum cooling power under these severe-duty conditions. Because of the variable and somewhat uncontrolled nature of the experiments, they serve only to show that for short vehicle trips, air conditioning can remain near or at full cooling capacity for 10-minutes or significantly longer and the cabin may be uncomfortably warm during much of this time.

  6. Unsteady Aerodynamics of Flapping Wing of a Bird

    Directory of Open Access Journals (Sweden)

    M. Agoes Moelyadi

    2013-04-01

    Full Text Available The unsteady flow behavior and time-dependent aerodynamic characteristics of the flapping motion of a bird’s wing were investigated using a computational method. During flapping, aerodynamic interactions between bird wing surfaces and surrounding flow may occur, generating local time-dependent flow changes in the flow field and aerodynamic load of birds. To study the effect of flapping speed on unsteady aerodynamic load, two kinds of computational simulations were carried out, namely a quasi-steady and an unsteady simulation. To mimic the movement of the down-stroke and the upstroke of a bird, the flapping path accorded to a sinus function, with the wing attitude changing in dihedral angle and time. The computations of time-dependent viscous flow were based on the solution of the Reynolds Averaged Navier-Stokes equations by applying the k-e turbulence model. In addition, the discretization for the computational domain around the model used multi-block structured grid to provide more accuracy in capturing viscous flow, especially in the vicinity of the wing and body surfaces, to obtain a proper wing-body geometry model. For this research, the seagull bird was chosen, which has high aspect ratio wings with pointed wing-tips and a high camber wing section. The results include mesh movement, velocity contours as well as aerodynamic coefficients of the flapping motion of the bird at various flapping frequencies.

  7. Abdominal wall reconstruction using De-epithelialized dermal flap: A ...

    African Journals Online (AJOL)

    Background: Although autogenous materials have been used in abdominal wall hernioplasty for a long time, the introduction of prosthetic materials diminished their popularity. However, these materials may be expensive, inappropriate or unavailable. The aim of this study is to determine the place of de-epithelialized dermal ...

  8. Magnitude of Myocutaneous Flaps and Factors Associated With Loss of Volume in Oral Cancer Reconstructive Surgery.

    Science.gov (United States)

    Sakamoto, Yuki; Yanamoto, Souichi; Ota, Yoshihide; Furudoi, Shungo; Komori, Takahide; Umeda, Masahiro

    2016-03-01

    Myocutaneous flaps are often used to repair oral and maxillofacial defects after surgery for oral cancer; however, their volume decreases during the postoperative period. To facilitate treatment planning, the authors measured the extent of such postoperative flap volume loss and identified associated factors in patients who underwent oral reconstruction with myocutaneous flaps. The authors designed and performed a retrospective observational study of patients who underwent reconstructive procedures involving rectus abdominal myocutaneous (RAM) or pectoralis major myocutaneous (PMMC) flaps at Tokai University Hospital, Kobe University Hospital, or Nagasaki University Hospital from April 2009 through March 2013. Flap type and other clinical variables were examined as potential predictors of flap loss. The primary outcome was flap loss at 6 months postoperatively. Correlations between each potential predictor and the primary outcome were examined using multiple regression analysis. The subjects were 75 patients whose oral defects were reconstructed with RAM flaps (n = 57) or PMMC flaps (n = 18). RAM flaps exhibited a mean volume shrinkage of 22% at 6 months postoperatively, which was less than the 27.5% displayed by the PMMC flaps, but the difference was not important. Renal failure, previous surgery of the oral region, postoperative radiotherapy, and postoperative serum albumin level were found to be meaningful risk factors for postoperative flap volume loss. The results of this study suggest that larger flaps should be used in patients who possess these risk factors or are scheduled to undergo postoperative radiotherapy. Future studies should examine the utility of postoperative nutritional management for preventing flap volume loss. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Free-style puzzle flap: the concept of recycling a perforator flap.

    Science.gov (United States)

    Feng, Kuan-Ming; Hsieh, Ching-Hua; Jeng, Seng-Feng

    2013-02-01

    Theoretically, a flap can be supplied by any perforator based on the angiosome theory. In this study, the technique of free-style perforator flap dissection was used to harvest a pedicled or free skin flap from a previous free flap for a second difficult reconstruction. The authors call this a free-style puzzle flap. For the past 3 years, the authors treated 13 patients in whom 12 pedicled free-style puzzle flaps were harvested from previous redundant free flaps and recycled to reconstruct soft-tissue defects at various anatomical locations. One free-style free puzzle flap was harvested from a previous anterolateral thigh flap for buccal cancer to reconstruct a foot defect. Total flap survival was attained in 12 of 13 flaps. One transferred flap failed completely. This patient had received postoperative radiotherapy after the initial cancer ablation and free anterolateral thigh flap reconstruction. Another free flap was used to close and reconstruct the wound. All the donor sites could be closed primarily. The free-style puzzle flap, harvested from a previous redundant free flap and used as a perforator flap to reconstruct a new defect, has proven to be versatile and reliable. When indicated, it is an alternative donor site for further reconstruction of soft-tissue defects.

  10. The vascularized groin lymph node flap (VGLN): Anatomical study and flap planning using multi-detector CT scanner. The golden triangle for flap harvesting.

    Science.gov (United States)

    Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha

    2017-09-01

    A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.

  11. Pulled Motzkin paths

    International Nuclear Information System (INIS)

    Janse van Rensburg, E J

    2010-01-01

    In this paper the models of pulled Dyck paths in Janse van Rensburg (2010 J. Phys. A: Math. Theor. 43 215001) are generalized to pulled Motzkin path models. The generating functions of pulled Motzkin paths are determined in terms of series over trinomial coefficients and the elastic response of a Motzkin path pulled at its endpoint (see Orlandini and Whittington (2004 J. Phys. A: Math. Gen. 37 5305-14)) is shown to be R(f) = 0 for forces pushing the endpoint toward the adsorbing line and R(f) = f(1 + 2cosh f))/(2sinh f) → f as f → ∞, for forces pulling the path away from the X-axis. In addition, the elastic response of a Motzkin path pulled at its midpoint is shown to be R(f) = 0 for forces pushing the midpoint toward the adsorbing line and R(f) = f(1 + 2cosh (f/2))/sinh (f/2) → 2f as f → ∞, for forces pulling the path away from the X-axis. Formal combinatorial identities arising from pulled Motzkin path models are also presented. These identities are the generalization of combinatorial identities obtained in directed paths models to their natural trinomial counterparts.

  12. Pulled Motzkin paths

    Energy Technology Data Exchange (ETDEWEB)

    Janse van Rensburg, E J, E-mail: rensburg@yorku.c [Department of Mathematics and Statistics, York University, Toronto, ON, M3J 1P3 (Canada)

    2010-08-20

    In this paper the models of pulled Dyck paths in Janse van Rensburg (2010 J. Phys. A: Math. Theor. 43 215001) are generalized to pulled Motzkin path models. The generating functions of pulled Motzkin paths are determined in terms of series over trinomial coefficients and the elastic response of a Motzkin path pulled at its endpoint (see Orlandini and Whittington (2004 J. Phys. A: Math. Gen. 37 5305-14)) is shown to be R(f) = 0 for forces pushing the endpoint toward the adsorbing line and R(f) = f(1 + 2cosh f))/(2sinh f) {yields} f as f {yields} {infinity}, for forces pulling the path away from the X-axis. In addition, the elastic response of a Motzkin path pulled at its midpoint is shown to be R(f) = 0 for forces pushing the midpoint toward the adsorbing line and R(f) = f(1 + 2cosh (f/2))/sinh (f/2) {yields} 2f as f {yields} {infinity}, for forces pulling the path away from the X-axis. Formal combinatorial identities arising from pulled Motzkin path models are also presented. These identities are the generalization of combinatorial identities obtained in directed paths models to their natural trinomial counterparts.

  13. Pulled Motzkin paths

    Science.gov (United States)

    Janse van Rensburg, E. J.

    2010-08-01

    In this paper the models of pulled Dyck paths in Janse van Rensburg (2010 J. Phys. A: Math. Theor. 43 215001) are generalized to pulled Motzkin path models. The generating functions of pulled Motzkin paths are determined in terms of series over trinomial coefficients and the elastic response of a Motzkin path pulled at its endpoint (see Orlandini and Whittington (2004 J. Phys. A: Math. Gen. 37 5305-14)) is shown to be R(f) = 0 for forces pushing the endpoint toward the adsorbing line and R(f) = f(1 + 2cosh f))/(2sinh f) → f as f → ∞, for forces pulling the path away from the X-axis. In addition, the elastic response of a Motzkin path pulled at its midpoint is shown to be R(f) = 0 for forces pushing the midpoint toward the adsorbing line and R(f) = f(1 + 2cosh (f/2))/sinh (f/2) → 2f as f → ∞, for forces pulling the path away from the X-axis. Formal combinatorial identities arising from pulled Motzkin path models are also presented. These identities are the generalization of combinatorial identities obtained in directed paths models to their natural trinomial counterparts.

  14. RECONSTRUCTION OF POST ELECTRIC BURN DEFECTS OF UPPER LIMB WITH DIFFERENT FLAPS

    Directory of Open Access Journals (Sweden)

    Satyajit

    2015-08-01

    Full Text Available INTRODUCTION: P ost electric burn defects are difficult to manage due to deep injury involving all the structures up to bony level. A good vascularized flap is required to resurface the defect for preventing the complication and for reconstruction of involved structures. AIM: Resurfacing the post electric burn defect with different flaps according to need of the defect. MATERIAL AND METHOD: All patients of electric burn hand and fore arm defect admitted to burn, p lastic and reconstructi ve department of SCB Medical College &hospital, Cuttack between January 2012 to December 2012 were included in the study. During this period the patients were followed up at weekly interval for first 2 month, then at 1 monthly interv al for next 6 - 8 month. OBSERVATION: Out of 40 cases of post electric burn forearm and hand reconstruction, 10 cases underwent groin flap cover, 6 cases underwent abdominal flap cover, 5 cases underwent cross finger flap cover 5 cases underwent free antero lateral thigh flap cover, 4 cases underwent free latissimus dorsi flap cover, 5 cases underwent first dorsal metacarpal artery flap cover, 5 cases reverse radial forearm flap cover. All the defects were resurfaced successfully with flaps. Four had marginal necrosis and six had wound infection. Eventually all flaps settled well without further intervention. Due to involvement of all important tendons & nerves, functional outcome is guarded. DISCUSSION: Hand and forearm are most commonly and most severely aff ected in electric burn injury because they are mostly first part of body to come in contact with electric circuit. Even though at initial part the injury appears to be superficial, deepe r structures like bone, tendon and neurovascular bundles are affected requiring flap cover for future reconstruction of these structures to get functional and sensate hand. CONCLUSION: Reconstruction of post electric burn defect of distal forearm and hand represents great challenge due to

  15. Optimization of Contact Force and Pull-in Voltage for Series based MEMS Switch

    Directory of Open Access Journals (Sweden)

    Abhijeet KSHIRSAGAR

    2010-04-01

    Full Text Available Cantilever based metal-to-metal contact type MEMS series switch has many applications namely in RF MEMS, Power MEMS etc. A typical MEMS switch consists of a cantilever as actuating element to make the contact between the two metal terminals of the switch. The cantilever is pulled down by applying a pull-in voltage to the control electrode that is located below the middle portion of the cantilever while only the tip portion of the cantilever makes contact between the two terminals. Detailed analysis of bending of the cantilever for different pull-in voltages reveals some interesting facts. At low pull-in voltage the cantilever tip barely touches the two terminals, thus resulting in very less contact area. To increase contact area a very high pull-in voltage is applied, but it lifts the tip from the free end due to concave curving of the cantilever in the middle region of the cantilever where the electrode is located. Again it results in less contact area. Furthermore, the high pull-in voltage produces large stress at the base of the cantilever close to the anchor. Therefore, an optimum, pull-in voltage must exist at which the concave curving is eliminated and contact area is maximum. In this paper authors report the finding of optimum contact force and pull-in voltage.

  16. PIV study of flow around unsteady airfoil with dynamic trailing-edge flap deflection

    Energy Technology Data Exchange (ETDEWEB)

    Gerontakos, P.; Lee, T. [McGill University, Department of Mechanical Engineering, Montreal, Quebec (Canada)

    2008-12-15

    The flow around an oscillating NACA 0015 airfoil with prescheduled trailing-edge flap motion control was investigated by using particle image velocimetry (PIV). Aerodynamic load coefficients, obtained via surface pressure measurements, were also acquired to supplement the PIV results. The results demonstrate that upward flap deflections led to an improved negative peak pitching moment coefficient C{sub m,peak}, mainly as a consequence of the increased suction pressure on the lower surface of the flap. The behavior of the leading-edge vortex (LEV) was largely unaffected. Its strength was, however, reduced slightly compared to that of the uncontrolled airfoil. No trailing-edge vortex was observed. For downward flap deflection, the strength of the LEV was found to be slightly increased. A favorable increase in C{sub l,max}, as a consequence of downward flap-induced positive camber effects, accompanied by a detrimental increase in the nose-down C{sub m,peak}, due to the large pressure increase on the lower surface of the flap, was also observed. (orig.)

  17. Abdominal- versus thigh-based reconstruction of perineal defects in patients with cancer.

    Science.gov (United States)

    Pang, John; Broyles, Justin M; Berli, Jens; Buretta, Kate; Shridharani, Sachin M; Rochlin, Danielle H; Efron, Jonathan E; Sacks, Justin M

    2014-06-01

    An abdominoperineal resection is an invasive procedure that leaves the patient with vast pelvic dead space. Traditionally, the vertical rectus abdominus myocutaneous flap is used to reconstruct these defects. Oftentimes, this flap cannot be used because of multiple ostomy placements or previous abdominal surgery. The anterolateral thigh flap can be used; however, the efficacy of this flap has been questioned. We report a single surgeon's experience with perineal reconstruction in patients with cancer with the use of either the vertical rectus abdominus myocutaneous flap or the anterolateral thigh flap to demonstrate acceptable outcomes with either repair modality. From 2010 to 2012, 19 consecutive patients with perineal defects secondary to cancer underwent flap reconstruction. A retrospective chart review of prospectively entered data was conducted to determine the frequency of short-term and long-term complications. This study was conducted at an academic, tertiary-care cancer center. Patients in the study were patients with cancer who were receiving perineal reconstruction. Interventions were surgical and included either abdomen- or thigh-based reconstruction. The main outcome measures included infection, flap failure, length of stay, and time to radiotherapy. Of the 19 patients included in our study, 10 underwent anterolateral thigh flaps and 9 underwent vertical rectus abdominus myocutaneous flaps for reconstruction. There were no significant differences in demographics between groups (p > 0.05). Surgical outcomes and complications demonstrated no significant differences in the rate of infection, hematoma, bleeding, or necrosis. The mean length of stay after reconstruction was 9.7 ± 3.4 days (± SD) in the anterolateral thigh flap group and 13.4 ± 7.7 days in the vertical rectus abdominus myocutaneous flap group (p > 0.05). The limitations of this study include a relatively small sample size and retrospective evaluation. This study suggests that the

  18. Management of the Sequelae of Severe Congenital Abdominal Wall Defects

    Directory of Open Access Journals (Sweden)

    Sara Fuentes

    2016-05-01

    Full Text Available BackgroundThe survival rate of newborns with severe congenital abdominal wall defects has increased. After successfully addressing life-threatening complications, it is necessary to focus on the cosmetic and functional outcomes of the abdominal wall.MethodsWe performed a chart review of five cases treated in our institution.ResultsFive patients, ranging from seven to 18 years of age, underwent the following surgical approaches: simple approximation of the rectus abdominis fascia, the rectus abdominis sheath turnover flap, the placement of submuscular tissue expanders, mesh repair, or a combination of these techniques depending on the characteristics of each individual case.ConclusionsPatients with severe congenital abdominal wall defects require individualized surgical treatment to address both the aesthetic and functional issues related to the sequelae of their defects.

  19. An evaluation of the fluoroscopy-guided percutaneous gastrostomy with the pull technique

    International Nuclear Information System (INIS)

    Uhm, Chang Wook; Won, Jong Yun; Yu, Jeong Sik; Ko, Heung Kyu; Lee, Kwang Hun; Lee, Do Yun; Lee, Jong Tae

    2008-01-01

    To evaluate the safety and usefulness of the fluoroscopy-guided percutaneous gastrostomy (FPG) using a large profile gastrostomy tube accompanied with the pull technique, and without the use of an endoscopy or a gastropexy. From March 2005 to February 2007, 25 patients underwent an FPG using a large profile gastrostomy tube accompanied by the pull technique, in which a 24F pull-type tube was inserted into a patient's mouth and was pulled to the upper abdominal puncture site using a snare, under fluoroscopy. The 18 patients with difficulty swallowing due to muscular atrophic lateral sclerosis or transitional myodystrophy included 5 cases of quadriplegia, 1 case of Parkinson's disease, and 1 metastatic mediastinal tumor. The technical success rate, occurrence of complications, and clinical outcomes were examined. The technical success rate was found to be 100%. In addition, the retention periods for the indwelling tube ranged from 1 to 24 months (mean: 6.5 months), with all tubes retained at a normal position with normal function. No procedure-related mortality occurred. One patient (4%) did however develop a complication in the form of ascites and ascitic fluid leakage around the tube, which was of hepatic origin and was ultimately resolved after the drainage of ascites. As a result of this study the FPG, accompanied with the pull technique using a 24F tube, should be considered as a safe and effective method for examining patients. It was found to have a high success rate and a low complication rate

  20. An evaluation of the fluoroscopy-guided percutaneous gastrostomy with the pull technique

    Energy Technology Data Exchange (ETDEWEB)

    Uhm, Chang Wook; Won, Jong Yun; Yu, Jeong Sik; Ko, Heung Kyu; Lee, Kwang Hun; Lee, Do Yun; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2008-04-15

    To evaluate the safety and usefulness of the fluoroscopy-guided percutaneous gastrostomy (FPG) using a large profile gastrostomy tube accompanied with the pull technique, and without the use of an endoscopy or a gastropexy. From March 2005 to February 2007, 25 patients underwent an FPG using a large profile gastrostomy tube accompanied by the pull technique, in which a 24F pull-type tube was inserted into a patient's mouth and was pulled to the upper abdominal puncture site using a snare, under fluoroscopy. The 18 patients with difficulty swallowing due to muscular atrophic lateral sclerosis or transitional myodystrophy included 5 cases of quadriplegia, 1 case of Parkinson's disease, and 1 metastatic mediastinal tumor. The technical success rate, occurrence of complications, and clinical outcomes were examined. The technical success rate was found to be 100%. In addition, the retention periods for the indwelling tube ranged from 1 to 24 months (mean: 6.5 months), with all tubes retained at a normal position with normal function. No procedure-related mortality occurred. One patient (4%) did however develop a complication in the form of ascites and ascitic fluid leakage around the tube, which was of hepatic origin and was ultimately resolved after the drainage of ascites. As a result of this study the FPG, accompanied with the pull technique using a 24F tube, should be considered as a safe and effective method for examining patients. It was found to have a high success rate and a low complication rate.

  1. In Planta Single-Molecule Pull-Down Reveals Tetrameric Stoichiometry of HD-ZIPIII:LITTLE ZIPPER Complexes.

    Science.gov (United States)

    Husbands, Aman Y; Aggarwal, Vasudha; Ha, Taekjip; Timmermans, Marja C P

    2016-08-01

    Deciphering complex biological processes markedly benefits from approaches that directly assess the underlying biomolecular interactions. Most commonly used approaches to monitor protein-protein interactions typically provide nonquantitative readouts that lack statistical power and do not yield information on the heterogeneity or stoichiometry of protein complexes. Single-molecule pull-down (SiMPull) uses single-molecule fluorescence detection to mitigate these disadvantages and can quantitatively interrogate interactions between proteins and other compounds, such as nucleic acids, small molecule ligands, and lipids. Here, we establish SiMPull in plants using the HOMEODOMAIN LEUCINE ZIPPER III (HD-ZIPIII) and LITTLE ZIPPER (ZPR) interaction as proof-of-principle. Colocalization analysis of fluorophore-tagged HD-ZIPIII and ZPR proteins provides strong statistical evidence of complex formation. In addition, we use SiMPull to directly quantify YFP and mCherry maturation probabilities, showing these differ substantially from values obtained in mammalian systems. Leveraging these probabilities, in conjunction with fluorophore photobleaching assays on over 2000 individual complexes, we determined HD-ZIPIII:ZPR stoichiometry. Intriguingly, these complexes appear as heterotetramers, comprising two HD-ZIPIII and two ZPR molecules, rather than heterodimers as described in the current model. This surprising result raises new questions about the regulation of these key developmental factors and is illustrative of the unique contribution SiMPull is poised to make to in planta protein interaction studies. © 2016 American Society of Plant Biologists. All rights reserved.

  2. Growth of Yb3+-doped Y2O3 single crystal rods by the micro-pulling-down method

    International Nuclear Information System (INIS)

    Mun, J.H.; Novoselov, A.; Yoshikawa, A.; Boulon, G.; Fukuda, T.

    2005-01-01

    The rare-earth sesquioxides (RE 2 O 3 , RE = Lu, Y and Sc) are very promising host crystals for advanced laser diode (LD)-pumped Yb 3+ -doped solid-state lasers due to unusual combination, almost unique of favourable structural, thermal and spectroscopic properties which are described. In spite of these favourable properties, the bulk single crystal growth technology for the rare-earth sesquioxides has not been established yet. The extremely high melting temperature at around 2400 deg. C has prevented it. However, we shall show that yttrium oxide crystals (Yb x Y 1-x ) 2 O 3 , x = 0.0, 0.005, 0.05, 0.08 and 0.15 of cylindrical shape as laser rods with 4.2 mm in diameter and 15-20 mm in length have been grown from rhenium crucibles by the micro-pulling-down method. The crystal quality characterisation of undoped Y 2 O 3 crystal was determined using X-ray rocking curve (XRC) analysis. Yb were homogeneously distributed in Y 2 O 3 host crystal

  3. Measurement of O-GlcNAcylated endothelial nitric oxide synthase by using 2',5'-ADP-Sepharose pull-down assay.

    Science.gov (United States)

    Long, Yang; Yan, Jianghong; Luo, Suxin; Liu, Zhenguo; Xia, Yong

    2017-11-15

    Endothelial nitric oxide synthase (eNOS) plays central roles in cardiovascular regulation and disease. eNOS function is critically affected by O-linked N-acetylglucosamine (O-GlcNAc) modification. The present method for measuring O-GlcNAcylated eNOS relies on immunoprecipitation. Such method exhibits low detection efficiency and is also costly. We here report a simplified assay by employing the high binding affinity of eNOS with the 2',5'-ADP-Sepharose resins. Together with the O-GlcNAc antibody, this assay readily allows the detection of O-GlcNAcylated eNOS in both cultured endothelial cells and rat vascular tissues. By using this assay, we demonstrate that eNOS O-GlcNAcylation is markedly elevated in the vessels of diabetic rats. Thus, a 2',5'-ADP-Sepharose-based pull-down assay is developed to measure O-GlcNAcylated eNOS. This assay is simple and efficient in detecting O-GlcNAcylated eNOS in cultured cells and animal tissues under both normal and disease conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Transversus Abdominis Plane Blocks with Single-Dose Liposomal Bupivacaine in Conjunction with a Nonnarcotic Pain Regimen Help Reduce Length of Stay following Abdominally Based Microsurgical Breast Reconstruction.

    Science.gov (United States)

    Jablonka, Eric M; Lamelas, Andreas M; Kim, Julie N; Molina, Bianca; Molina, Nathan; Okwali, Michelle; Samson, William; Sultan, Mark R; Dayan, Joseph H; Smith, Mark L

    2017-08-01

    Side effects associated with use of postoperative narcotics for pain control can delay recovery after abdominally based microsurgical breast reconstruction. The authors evaluated a nonnarcotic pain control regimen in conjunction with bilateral transversus abdominis plane blocks on facilitating early hospital discharge. A retrospective analysis was performed of consecutive patients who underwent breast reconstruction using abdominally based free flaps, with or without being included in a nonnarcotic protocol using intraoperative transversus abdominis plane blockade. During this period, the use of locoregional analgesia evolved from none (control), to continuous bupivacaine infusion transversus abdominis plane and catheters, to single-dose transversus abdominis plane blockade with liposomal bupivacaine solution. Demographic factors, length of stay, inpatient opioid consumption, and complications were reported for all three groups. One hundred twenty-eight consecutive patients (182 flaps) were identified. Forty patients (62 flaps) were in the infusion-liposomal bupivacaine group, 48 (66 flaps) were in the single-dose blockade-catheter group, and 40 (54 flaps) were in the control group. The infusion-liposomal bupivacaine patients had a significantly shorter hospital stay compared with the single-dose blockade-catheter group (2.65 ± 0.66 versus 3.52 ± 0.92 days; p plane blocks performed with single injections of liposomal bupivacaine help facilitate early hospital discharge after abdominally based microsurgical breast reconstruction. A trend toward consistent discharge by postoperative day 2 was seen. This could result in significant cost savings for health care systems. Therapeutic, III.

  5. Keystone flaps in coloured skin: Flap technology for the masses?

    Directory of Open Access Journals (Sweden)

    Satish P Bhat

    2013-01-01

    Full Text Available Introduction: Viscoelastic properties of skin in coloured ethnic groups are less favourable compared to Caucasians for executing Keystone flaps. Keystone flaps have so far been evaluated and reported only in Caucasians. The potential of Keystone flaps in a coloured ethnic group is yet unknown. Aim: This article reviews the experience to reconstruct skin defects presenting in a coloured ethnic group, by using Keystone flaps, with a review of existing literature. Design: Uncontrolled case series. Materials and Methods: This retrospective review involves 55 consecutive Keystone flaps used from 2009 to 2012, for skin defects in various locations. Patient demographic data, medical history, co-morbidity, surgical indication, defect features, complications, and clinical outcomes are evaluated and presented. Results: In this population group with Fitzpatrick type 4 and 5 skin, the average patient age was 35.73. Though 60% of flaps (33/55 in the series involved specific risk factors, only two flaps failed. Though seven flaps had complications, sound healing was achieved by suitable intervention giving a success rate of 96.36%. Skin grafts were needed in only four cases. Conclusions: Keystone flaps achieve primary wound healing for a wide spectrum of defects with an acceptable success rate in a coloured skin population with unfavorable biophysical properties. By avoiding conventional local flaps and at times even microsurgical flaps, good aesthetic outcome is achieved without additional skin grafts or extensive operative time. All advantages seen in previous studies were verified. These benefits can be most appreciated in coloured populations, with limited resources and higher proportion of younger patients and unfavorable defects.

  6. Pedicled perforator flaps

    DEFF Research Database (Denmark)

    Demirtas, Yener; Ozturk, Nuray; Kelahmetoglu, Osman

    2009-01-01

    Described in this study is a surgical concept that supports the "consider and use a pedicled perforator flap whenever possible and indicated" approach to reconstruct a particular skin defect. The operation is entirely free-style; the only principle is to obtain a pedicled perforator flap...... to reconstruct the defect. The perforators are marked with a hand-held Doppler probe and multiple flaps are designed. The appropriate flap is elevated after identifying the perforator(s). Dissection of the perforator(s) or complete incision of the flap margins are not mandatory if the flap is mobilized...... adequately to cover the defect. Defects measuring 3 x 3 cm up to 20 x 20 cm at diverse locations were successfully reconstructed in 20 of 21 patients with 26 flaps. Pedicled perforator flaps offer us reliable and satisfactory results of reconstruction at different anatomic territories of the body. It sounds...

  7. Growth and luminescent properties of the Ce, Pr doped NaCl single crystals grown by the modified micro-pulling-down method

    International Nuclear Information System (INIS)

    Yokota, Yuui; Yanagida, Takayuki; Fujimoto, Yutaka; Nikl, Martin; Yoshikawa, Akira

    2010-01-01

    We have investigated luminescent properties of nondope, Ce and Pr doped NaCl [nondope NaCl, Ce:NaCl, Pr:NaCl] single crystals grown by a modified micro-pulling-down method with a removable chamber system. Nondope, Ce 1% and Pr 1% doped NaCl crystals with a single phase of NaCl structure were obtained and the crystals indicated general crystal quality by the X-ray rocking curve measurement. For the nondope NaCl and Pr:NaCl crystals, the transmittance spectra indicated almost more than 60% in the wavelength from 200 to 800 nm and an absorption of Ce 3+ ion was observed in the transmittance spectrum of Ce:NaCl crystal. The emission spectrum originated from Ce 3+ 5d-4f transition appeared around 300 nm in the photoluminescence spectrum and the decay time was 19.7 ns.

  8. Trichotillomania (Hair-Pulling Disorder)

    Science.gov (United States)

    ... pulling Biting, chewing or eating pulled-out hair Playing with pulled-out hair or rubbing it across ... of trichotillomania: Family history. Genetics may play a role in the development of trichotillomania, and the disorder ...

  9. Head and neck reconstruction with pedicled flaps in the free flap era.

    Science.gov (United States)

    Mahieu, R; Colletti, G; Bonomo, P; Parrinello, G; Iavarone, A; Dolivet, G; Livi, L; Deganello, A

    2016-12-01

    Nowadays, the transposition of microvascular free flaps is the most popular method for management of head and neck defects. However, not all patients are suitable candidates for free flap reconstruction. In addition, not every defect requires a free flap transfer to achieve good functional results. The aim of this study was to assess whether pedicled flap reconstruction of head and neck defects is inferior to microvascular free flap reconstruction in terms of complications, functionality and prognosis. The records of consecutive patients who underwent free flap or pedicled flap reconstruction after head and neck cancer ablation from 2006 to 2015, from a single surgeon, in the AOUC Hospital, Florence Italy were analysed. A total of 93 patients, the majority with oral cancer (n = 59), were included, of which 64 were pedicled flap reconstructions (69%). The results showed no significant differences in terms of functional outcome, flap necrosis and complications in each type of reconstruction. Multivariate regression analysis of flap necrosis and functional impairments showed no associated factors. Multivariate regression analysis of complicated flap healing showed that only comorbidities remained an explaining factor (p = 0.019). Survival analysis and proportional hazard regression analysis regarding cancer relapse or distant metastasis, showed no significant differences in prognosis of patients concerning both types of reconstruction. In this retrospective, non-randomised study cohort, pedicled flaps were not significantly inferior to free flaps for reconstruction of head and neck defects, considering functionality, complications and prognosis. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  10. Analysis of high aspect ratio jet flap wings of arbitrary geometry.

    Science.gov (United States)

    Lissaman, P. B. S.

    1973-01-01

    Paper presents a design technique for rapidly computing lift, induced drag, and spanwise loading of unswept jet flap wings of arbitrary thickness, chord, twist, blowing, and jet angle, including discontinuities. Linear theory is used, extending Spence's method for elliptically loaded jet flap wings. Curves for uniformly blown rectangular wings are presented for direct performance estimation. Arbitrary planforms require a simple computer program. Method of reducing wing to equivalent stretched, twisted, unblown planform for hand calculation is also given. Results correlate with limited existing data, and show lifting line theory is reasonable down to aspect ratios of 5.

  11. Growth and luminescent properties of the Ce, Pr doped NaCl single crystals grown by the modified micro-pulling-down method

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Yuui, E-mail: y-yokota@tagen.tohoku.ac.j [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University/2-1-1, Katahira, Aoba-ku, Sendai (Japan); Yanagida, Takayuki; Fujimoto, Yutaka [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University/2-1-1, Katahira, Aoba-ku, Sendai (Japan); Nikl, Martin [Institute of Physics, Academy of Sciences of the Czech Republic/6253, Prague (Czech Republic); Yoshikawa, Akira [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University/2-1-1, Katahira, Aoba-ku, Sendai (Japan); New Industry Creation Hatchery Center (NICHe), Tohoku University/2-1-1, Katahira, Aoba-ku, Sendai (Japan)

    2010-03-15

    We have investigated luminescent properties of nondope, Ce and Pr doped NaCl [nondope NaCl, Ce:NaCl, Pr:NaCl] single crystals grown by a modified micro-pulling-down method with a removable chamber system. Nondope, Ce 1% and Pr 1% doped NaCl crystals with a single phase of NaCl structure were obtained and the crystals indicated general crystal quality by the X-ray rocking curve measurement. For the nondope NaCl and Pr:NaCl crystals, the transmittance spectra indicated almost more than 60% in the wavelength from 200 to 800 nm and an absorption of Ce{sup 3+} ion was observed in the transmittance spectrum of Ce:NaCl crystal. The emission spectrum originated from Ce{sup 3+} 5d-4f transition appeared around 300 nm in the photoluminescence spectrum and the decay time was 19.7 ns.

  12. Forward flight of swallowtail butterfly with simple flapping motion

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiroto [School of Engineering and Applied Sciences, Harvard University, 60 Oxford Street, Cambridge, MA 02138 (United States); Shimoyama, Isao, E-mail: isao@i.u-tokyo.ac.j [Department of Mechano-Informatics, Graduate School of Information Science and Technology, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 (Japan)

    2010-06-15

    Unlike other flying insects, the wing motion of swallowtail butterflies is basically limited to flapping because their fore wings partly overlap their hind wings, structurally restricting the feathering needed for active control of aerodynamic force. Hence, it can be hypothesized that the flight of swallowtail butterflies is realized with simple flapping, requiring little feedback control of the feathering angle. To verify this hypothesis, we fabricated an artificial butterfly mimicking the wing motion and wing shape of a swallowtail butterfly and analyzed its flights using images taken with a high-speed video camera. The results demonstrated that stable forward flight could be realized without active feathering or feedback control of the wing motion. During the flights, the artificial butterfly's body moved up and down passively in synchronization with the flapping, and the artificial butterfly followed an undulating flight trajectory like an actual swallowtail butterfly. Without feedback control of the wing motion, the body movement is directly affected by change of aerodynamic force due to the wing deformation; the degree of deformation was determined by the wing venation. Unlike a veinless wing, a mimic wing with veins generated a much higher lift coefficient during the flapping flight than in a steady flow due to the large body motion.

  13. Forward flight of swallowtail butterfly with simple flapping motion

    International Nuclear Information System (INIS)

    Tanaka, Hiroto; Shimoyama, Isao

    2010-01-01

    Unlike other flying insects, the wing motion of swallowtail butterflies is basically limited to flapping because their fore wings partly overlap their hind wings, structurally restricting the feathering needed for active control of aerodynamic force. Hence, it can be hypothesized that the flight of swallowtail butterflies is realized with simple flapping, requiring little feedback control of the feathering angle. To verify this hypothesis, we fabricated an artificial butterfly mimicking the wing motion and wing shape of a swallowtail butterfly and analyzed its flights using images taken with a high-speed video camera. The results demonstrated that stable forward flight could be realized without active feathering or feedback control of the wing motion. During the flights, the artificial butterfly's body moved up and down passively in synchronization with the flapping, and the artificial butterfly followed an undulating flight trajectory like an actual swallowtail butterfly. Without feedback control of the wing motion, the body movement is directly affected by change of aerodynamic force due to the wing deformation; the degree of deformation was determined by the wing venation. Unlike a veinless wing, a mimic wing with veins generated a much higher lift coefficient during the flapping flight than in a steady flow due to the large body motion.

  14. [Saphenous perforator flap].

    Science.gov (United States)

    Winkel, R; Tajsic, N; Husum, H; Schlageter, M; Hanebuth, G; Hoffmann, R

    2013-04-01

    Replacement of full thickness soft tissue defects in the lower leg and ankle, appropriate to the defect and following the course of blood vessels feeding the skin of a distally hinged fasciocutaneous flap most reliably based on the individual anatomy of distal perforators of the posterior tibial artery. Full thickness soft tissue defects, up to 12 cm in length and up to 8 cm in width. Sufficient vascularization of the foot required, in osteomyelitis, and when joints, fractures, implants and tendons are exposed and when a split skin graft, a local flap, a suralis perforator flap or a free flap is not indicated. For patients, in whom a 1-2 h operation is not possible; necessity of angioplasty; decollement or scars around the distal perforators of the posterior tibial artery; local infection or necrosis of soft tissues and/or bone, which cannot be totally excised. Radical debridement; flap dissection without tourniquet; microdissection; design of the flap on the skin: pivot point ~ 10 cm (6-14 cm) proximal of the tip of the medial malleolus; base ~ 5 cm in width, between the course of the saphenous nerve and of the great saphenous vein and the Achilles tendon; adipofascial pedicle up to 15 cm in length sited over the septum between soleus and flexor digitorum muscles, following the course of the saphenous nerve, with a central skin stripe, which expands into a proximal skin island; skin island is outlined similar to the defect, but larger by 1 to 2 cm, surrounded by an adipofascial border: adjustment of the planning as well as of the elevation of these flaps according to the individual position and the caliber of perforators requires in each case the search for a perforator at the estimated pivot point. Delay of transposition, if the division of more than one perforator proximal to the pivot point obviously diminishes circulation. No "tunnelling "of the pedicle; defects of skin due to the elevation of the flap are replaced by split and meshed skin grafts or temporary

  15. Analysis on the Interaction Domain of VirG and Apyrase by Pull-Down Assay

    Directory of Open Access Journals (Sweden)

    Yu Wang

    2014-11-01

    Full Text Available VirG is outer membrane protein of Shigella and affects the spread of Shigella. Recently it has been reported that apyrase influences the location of VirG, although the underlying mechanism remains poorly understood. The site of interaction between apyrase and VirG is the focus of our research. First we constructed recombinant plasmid pHIS-phoN2 and pS-(v1–1102, v53–758, v759–1102, v53–319, v320–507, v507–758 by denaturation-renaturation, the phoN2:kan mutant of Shigella flexneri 5a M90T by a modified version of the lambda red recombination protocol originally described by Datsenko and Wanner and the complemented strain M90TΔphoN2/pET24a(PhisphoN2. Second, the recombinant plasmid pHIS-phoN2 and the pS-(v1–1102, v53–758, v759–1102, v53–319, v320–507, v507–758 were transformed into E. coli BL21 (DE3 and induced to express the fusion proteins. Third, the fusion proteins were purified and the interaction of VirG and apyrase was identified by pull-down. Fourth, VirG was divided and the interaction site of apyrase and VirG was determined. Finally, how apyrase affects the function of VirG was analyzed by immunofluorescence. Accordingly, the results provided the data supporting the fact that apyrase combines with the α-domain of VirG to influence the function of VirG.

  16. Hair Pulling (Trichotillomania)

    Science.gov (United States)

    ... for Families - Vietnamese Spanish Facts for Families Guide Hair Pulling (Trichotillomania) No. 96; Reviewed July 2013 It ... for children and adolescents to play with their hair. However, frequent or obsessive hair pulling can lead ...

  17. Abdominal elephantiasis: a case report.

    Science.gov (United States)

    Hanna, Dominique; Cloutier, Richard; Lapointe, Roch; Desgagné, Antoine

    2004-01-01

    Elephantiasis is a well-known condition in dermatology usually affecting the legs and external genitalia. It is characterized by chronic inflammation and obstruction of the lymphatic channels and by hypertrophy of the skin and subcutaneous tissues. The etiology is either idiopathic or caused by a variety of conditions such as chronic filarial disease, leprosy, leishmaniasis, and chronic recurrent cellulites. Elephantiasis of the abdominal wall is very rare. A complete review of the English and French literature showed only two cases reported in 1966 and 1973, respectively. We report a third case of abdominal elephantiasis and we briefly review this entity. We present the case of a 51-year-old woman who had progressively developed an enormous pediculated abdominal mass hanging down her knees. The skin was thickened, hyperpigmented, and fissured. She had a history of multiple abdominal cellulites. She underwent an abdominal lipectomy. Histopathology of the specimen confirmed the diagnosis of abdominal elephantiasis. Abdominal elephantiasis is a rare disease that represents end-stage failure of lymph drainage. Lipectomy should be considered in the management of this condition.

  18. Cost analysis of postmastectomy reconstruction: A comparison of two staged implant reconstruction using tissue expander and acellular dermal matrix with abdominal-based perforator free flaps.

    Science.gov (United States)

    Tran, Bao Ngoc N; Fadayomi, Ayotunde; Lin, Samuel J; Singhal, Dhruv; Lee, Bernard T

    2017-09-01

    Two staged tissue expander-implant with acellular dermal matrix (TE/I + ADM) and deep inferior epigastric perforator (DIEP) flap are the most common implant and autologous methods of reconstruction in the U.S. Implant-based techniques are disproportionally more popular, partially due to its presumed cost effectiveness. We performed a comprehensive cost analysis to compare TE/I + ADM and DIEP flap. A comparative cost analysis of TE/I + ADM and DIEP flap was performed. Medicare reimbursement costs for each procedure and their associated complications were calculated. Pooled probabilities of complications including cellulitis, seroma, skin necrosis, implant removal, flap loss, partial flap loss, and fat necrosis, were calculated using published studies from 2010 to 2016. Average actual cost for successful TE/I + ADM and DIEP flap were $13 304.55 and $10 237.13, respectively. Incorporating pooled complication data from published literature resulted in an increase in cost to $13 963.46 for TE/I + ADM and $12 624.29 for DIEP flap. The expected costs for successful TE/I + ADM and DIEP flap were $9700.35 and $8644.23, which are lower than the actual costs. DIEP flap breast reconstruction incurs lower costs compared to TE/I + ADM. These costs are lower at baseline and when additional costs from pooled complications are incorporated. © 2017 Wiley Periodicals, Inc.

  19. Recipient vessel selection in immediate breast reconstruction with free abdominal tissue transfer after nipple-sparing mastectomy.

    Science.gov (United States)

    Yang, Sung Jun; Eom, Jin Sup; Lee, Taik Jong; Ahn, Sei Hyun; Son, Byung Ho

    2012-05-01

    Nipple-sparing mastectomy (NSM) is gaining popularity due to its superior aesthetic results. When reconstructing the breast with free abdominal tissue transfer, we must readdress the recipient vessel, because NSM can cause difficulty in access to the chest vessel. Between June 2006 and March 2011, a total of 92 women underwent NSM with free abdominal tissue transfer. A lateral oblique incision was used for the nipple-sparing mastectomy. For recipient vessels, the internal mammary vessels were chosen if the mastectomy flap did not block access to the vessels. If it did, the thoracodorsal vessels were used. Age, degree of breast ptosis, weight of the mastectomy specimen, and related complications of the internal mammary vessel group and the thoracodorsal vessel group were compared. Thoracodorsal vessels were used as recipient vessels in 59 cases, and internal mammary vessels in 33 cases including 4 cases with perforators of the internal mammary vessels. Breast reconstruction was successful in all cases except one case involving a total flap failure, which was replaced by a silicone gel implant. The internal mammary group and the thoracodorsal group were similar in terms of age, height, breast weight, and degree of ptosis. The flap related complications such as flap loss and take-back operation rates were not significantly different between the two groups. The rate of nipple necrosis was higher in the internal mammary group. The thoracodorsal vessels could produce comparable outcomes in breast reconstruction after nipple-sparing mastectomies. If access to internal mammary vessels is difficult, the thoracodorsal vessel can be a better choice.

  20. Recipient Vessel Selection in Immediate Breast Reconstruction with Free Abdominal Tissue Transfer after Nipple-Sparing Mastectomy

    Directory of Open Access Journals (Sweden)

    Sung Jun Yang

    2012-05-01

    Full Text Available BackgroundNipple-sparing mastectomy (NSM is gaining popularity due to its superior aesthetic results. When reconstructing the breast with free abdominal tissue transfer, we must readdress the recipient vessel, because NSM can cause difficulty in access to the chest vessel.MethodsBetween June 2006 and March 2011, a total of 92 women underwent NSM with free abdominal tissue transfer. A lateral oblique incision was used for the nipple-sparing mastectomy. For recipient vessels, the internal mammary vessels were chosen if the mastectomy flap did not block access to the vessels. If it did, the thoracodorsal vessels were used. Age, degree of breast ptosis, weight of the mastectomy specimen, and related complications of the internal mammary vessel group and the thoracodorsal vessel group were compared.ResultsThoracodorsal vessels were used as recipient vessels in 59 cases, and internal mammary vessels in 33 cases including 4 cases with perforators of the internal mammary vessels. Breast reconstruction was successful in all cases except one case involving a total flap failure, which was replaced by a silicone gel implant. The internal mammary group and the thoracodorsal group were similar in terms of age, height, breast weight, and degree of ptosis. The flap related complications such as flap loss and take-back operation rates were not significantly different between the two groups. The rate of nipple necrosis was higher in the internal mammary group.ConclusionsThe thoracodorsal vessels could produce comparable outcomes in breast reconstruction after nipple-sparing mastectomies. If access to internal mammary vessels is difficult, the thoracodorsal vessel can be a better choice.

  1. An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions.

    Science.gov (United States)

    Hummelink, S; Verhulst, Arico C; Maal, Thomas J J; Hoogeveen, Yvonne L; Schultze Kool, Leo J; Ulrich, Dietmar J O

    2017-07-01

    Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available nowadays, we can combine information to preoperatively plan the optimal flap volume to be harvested. In this proof-of-concept, we investigated whether projection of a virtual flap planning onto the patient's abdomen using a projection method could result in harvesting the correct flap volume. In six patients (n = 9 breasts), 3D stereophotogrammetry and CTA data were combined from which a virtual flap planning was created comprising perforator locations, blood vessel trajectory and flap size. All projected perforators were verified with Doppler ultrasound. Intraoperative flap measurements were collected to validate the determined flap delineation volume. The measured breast volume using 3D stereophotogrammetry was 578 ± 127 cc; on CTA images, 527 ± 106 cc flap volumes were planned. The nine harvested flaps weighed 533 ± 109 g resulting in a planned versus harvested flap mean difference of 5 ± 27 g (flap density 1.0 g/ml). In 41 out of 42 projected perforator locations, a Doppler signal was audible. This proof-of-concept shows in small numbers that flap volumes can be included into a virtual DIEP flap planning, and transferring the virtual planning to the patient through a projection method results in harvesting approximately the same volume during surgery. In our opinion, this innovative approach is the first step in consequently achieving symmetric breast volumes in DIEP flap breast reconstructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Blowing Flap Experiment: PIV Measurements

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.; Bremmer, David M.

    2004-01-01

    PIV measurements of the flow in the region of a flap side edge are presented for several flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the flap vortex system. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

  3. Experimental Study of Wake / Flap Interaction Noise and the Reduction of Flap Side Edge Noise

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.; Plassman, Gerald E.

    2016-01-01

    The effects of the interaction of a wake with a half-span flap on radiated noise are examined. The incident wake is generated by bars of various widths and lengths or by a simplified landing gear model. Single microphone and phased array measurements are used to isolate the effects of the wake interaction on the noise radiating from the flap side edge and flap cove regions. The effects on noise of the wake generator's geometry and relative placement with respect to the flap are assessed. Placement of the wake generators upstream of the flap side edge is shown to lead to the reduction of flap side edge noise by introducing a velocity deficit and likely altering the instabilities in the flap side edge vortex system. Significant reduction in flap side edge noise is achieved with a bar positioned directly upstream of the flap side edge. The noise reduction benefit is seen to improve with increased bar width, length and proximity to the flap edge. Positioning of the landing gear model upstream of the flap side edge also leads to decreased flap side edge noise. In addition, flap cove noise levels are significantly lower than when the landing gear is positioned upstream of the flap mid-span. The impact of the local flow velocity on the noise radiating directly from the landing gear is discussed. The effects of the landing gear side-braces on flap side edge, flap cove and landing gear noise are shown.

  4. Trunk response and stability in standing under sagittal-symmetric pull-push forces at different orientations, elevations and magnitudes.

    Science.gov (United States)

    El Ouaaid, Z; Shirazi-Adl, A; Plamondon, A

    2018-03-21

    To reduce lifting and associated low back injuries, manual material handling operations often involve pulling-pushing of carts at different weights, orientations, and heights. The loads on spine and risk of injury however need to be investigated. The aim of this study was to evaluate muscle forces, spinal loads and trunk stability in pull-push tasks in sagittal-symmetric, static upright standing posture. Three hand-held load magnitudes (80, 120 and 160 N) at four elevations (0, 20, 40 and 60 cm to the L5-S1) and 24 force directions covering all pull/push orientations were considered. For this purpose, a musculoskeletal finite element model with kinematics measured earlier were used. Results demonstrated that peak spinal forces occur under inclined pull (lift) at upper elevations but inclined push at the lowermost one. Minimal spinal loads, on the other hand, occurred at and around vertical pull directions. Overall, spinal forces closely followed variations in the net external moment of pull-push forces at the L5-S1. Local lumbar muscles were most active in pulls while global extensor muscles in lifts. The trunk stability margin decreased with load elevation except at and around horizontal push; it peaked under pulls and reached minimum at vertical lifts. It also increased with antagonist activity in muscles and intra-abdominal pressure. Results provide insight into the marked effects of variation in the load orientation and elevation on muscle forces, spinal loads and trunk stability and hence offer help in rehabilitation, performance enhancement training and design of safer workplaces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. PushPull++

    KAUST Repository

    Lipp, Markus

    2014-07-22

    PushPull tools are implemented in most commercial 3D modeling suites. Their purpose is to intuitively transform a face, edge, or vertex, and then to adapt the polygonal mesh locally. However, previous approaches have limitations: Some allow adjustments only when adjacent faces are orthogonal; others support slanted surfaces but never create new details. Moreover, self-intersections and edge-collapses during editing are either ignored or work only partially for solid geometry. To overcome these limitations, we introduce the PushPull++ tool for rapid polygonal modeling. In our solution, we contribute novel methods for adaptive face insertion, adjacent face updates, edge collapse handling, and an intuitive user interface that automatically proposes useful drag directions. We show that PushPull++ reduces the complexity of common modeling tasks by up to an order of magnitude when compared with existing tools. Copyright © ACM.

  6. Electromyographic assessment of trunk and shoulder muscles during a Pilates pull-up exercise

    Directory of Open Access Journals (Sweden)

    Isabel C.N. Sacco

    2014-06-01

    Full Text Available This study compares surface electromyographic activity of the internal oblique, rectus abdominis, multifidus, iliocostalis, anterior deltoids during the pull-up on a lower and on a higher difficulty level. We assessed nine adults with previous experience in Pilates. The root mean square (RMS values were normalized by maximum isometric contraction for each participant. During the ascent phase, the low spring position showed a significantly higher RMS than the high spring position of 8.9% for deltoid, 17.2% for internal oblique, 22.3% for rectus abdominis, 4.1% for iliocostalis, and 5.6% for multifidus, and in the descent phase, the RMS in the lower spring exceeded significantly the high spring position in 1.6% for the deltoid, 10% for internal oblique, 31.4% for rectus abdominis and 11.4% for iliocostalis. There was no predominance of abdominal muscles over the shoulder muscle in any spring position. The pull-up exercise can be a useful choice for the core and anterior deltoid muscles strengthening.

  7. Combined Continuous Paravertebral and TAP Blocks for Pain Management after TRAM Flap Breast Reconstruction: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    V. RaoKadam

    2015-03-01

    Full Text Available Transverse Rectus Abdominis Musculocutaneous (TRAM flap surgery is a prolonged and extensive procedure that requires multiple incisions. Recently, Transverse Abdominis Plane (TAP blocks have been found to be reliable method of providing regional analgesia for lower abdominal surgery and paravertebral block for pain management after breast surgery. Since the TRAM flap surgery involves both abdomen and thorax, the combination of these two blocks to manage post operative pain could be effective. This manuscript is one of the initial cases reporting of the use of these techniques in which triple catheters with ropivacaine infusion in breast reconstruction surgery were successfully used with reduced pain scores and opioid consumption.

  8. The transverse musculocutaneous gracilis flap for breast reconstruction: guidelines for flap and patient selection.

    Science.gov (United States)

    Schoeller, Thomas; Huemer, Georg M; Wechselberger, Gottfried

    2008-07-01

    The transverse musculocutaneous gracilis (TMG) flap has received little attention in the literature as a valuable alternative source of donor tissue in the setting of breast reconstruction. The authors give an in-depth review of their experience with breast reconstruction using the TMG flap. A retrospective review of 111 patients treated with a TMG flap for breast reconstruction in an immediate or a delayed setting between August of 2002 and July of 2007 was undertaken. Of these, 26 patients underwent bilateral reconstruction and 68 underwent unilateral reconstruction, and 17 patients underwent reconstruction unilaterally with a double TMG flap. Patient age ranged between 24 and 65 years (mean, 37 years). Twelve patients had to be taken back to the operating room because of flap-related problems and nine patients underwent successful revision microsurgically, resulting in three complete flap losses in a series of 111 patients with 154 transplanted TMG flaps. Partial flap loss was encountered in two patients, whereas fat tissue necrosis was managed conservatively in six patients. Donor-site morbidity was an advantage of this flap, with a concealed scar and minimal contour irregularities of the thigh, even in unilateral harvest. Complications included delayed wound healing (n = 10), hematoma (n = 5), and transient sensory deficit over the posterior thigh (n = 49). The TMG flap is more than an alternative to the deep inferior epigastric perforator (DIEP) flap in microsurgical breast reconstruction in selected patients. In certain indications, such as bilateral reconstructions, it possibly surpasses the DIEP flap because of a better concealed donor scar and easier harvest.

  9. Colgajos de perforantes de las arterias epigástricas inferiores profunda y superficial Deep and superficial inferior epigastric artery perforator flaps

    Directory of Open Access Journals (Sweden)

    A. R. Gagnon

    2006-12-01

    Full Text Available Con el desarrollo de los colgajos miocutáneos de recto abdominal (TRAM, el abdomen inferior ha sido reconocido como la principal área dadora de tejidos autólogos de alta calidad, especialmente útiles en reconstrucción mamaria. Más recientemente la habilidad para obtener componentes adiposocutáneos similares sin sacrificar el músculo recto ha revolucionado el campo de la Cirugía Reconstructiva. El advenimiento de los colgajos de perforantes ha permitido a los cirujanos plásticos lograr los mismos buenos resultados estéticos que con los colgajos miocutáneos tradicionales, pero con un considerable descenso en la morbilidad del área donante. Con los colgajos de perforantes de la arteria epigástrica inferior profunda (DIEP y de la arteria epigástrica inferior superficial (SIEA, los pacientes han incrementado sus opciones de reconstrucción. Este artículo revisa la anatomía quirúrgica de la pared abdominal relativa a los colgajos SIEA y DIEP. Se explican detalladamente los pasos principales para la preparación preoperatoria, la técnica quirúrgica y los cuidados postoperatorios. Se discuten las ventajas y desventajas y se presen- tan los trucos técnicos que pueden ayudar a mejorar el resultado final. Además se ilustran con ayuda de casos clínicos las indicaciones típicas y atípicas.Following the development of the transverse rectus abdominis myocutaneous (TRAM flap, the lower abdomen has been recognized as a prime source of high quality autogenous tissue, especially useful in breast reconstruction. More recently, the ability to harvest a similar adipocutaneous component without sacrifice of the rectus muscle has revolutionized the field of reconstructive surgery. The advent of perforator flaps has allowed plastic surgeons to achieve the same highly esthetic results as with the former myocutaneous flaps while significantly decreasing the donor site morbidity. With the deep inferior epigastric artery perforator (DIEP flap and

  10. Curative effect observation of n-flap and off-flap EPi-LASIK in ametropia

    Directory of Open Access Journals (Sweden)

    Chao Liu

    2015-11-01

    Full Text Available AIM:To observe the clinical effect of on-flap and off-flap epipolis laser in situ keratomileusis(EPi-LASIKin ametropia.METHODS: Sixty-eight myopia patients(136 eyesreceiving surgical treatment were selected and divided into research group and control group according to different therapies. The patients in research group adopted off-flap EPi-LASIK and those in control group adopted on-flap EPi-LASIK. The index like uncorrected visual acuity, diopter and Haze of two groups before surgery, 1wk, 1 and 4mo after surgery was observed. RESULTS: One month after surgery, the uncorrected visual acuity of research group was 1.33±0.22 while that of control group was 1.22±0.19(PPPCONCLUSION:On-flap and off-flap EPi-LASIK are safe and effective surgery approaches in the clinical treatment of ametropia. The presence of corneal epithelial flap has a certain effect in the postoperative clinical outcome at early stage. The impact will be gradually reduced over time.

  11. Pedicled Temporalis Muscle Flap for Craniofacial Reconstruction: A 35-Year Clinical Experience with 366 Flaps.

    Science.gov (United States)

    Spanio di Spilimbergo, Stefano; Nordera, Paolo; Mardini, Samir; Castiglione, Giusy; Chim, Harvey; Pinna, Vittore; Brunello, Massimo; Cusino, Claudio; Roberto, Squaquara; Baciliero, Ugo

    2017-02-01

    In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. Therapeutic, IV.

  12. Head and neck reconstruction with pedicled flaps in the free flap era

    NARCIS (Netherlands)

    Mahieu, R.; Colletti, G.; Bonomo, P.; Parrinello, G.; Iavarone, A.; Dolivet, G.; Livi, L.; Deganello, A.

    2016-01-01

    Nowadays, the transposition of microvascular free flaps is the most popular method for management of head and neck defects. However, not all patients are suitable candidates for free flap reconstruction. In addition, not every defect requires a free flap transfer to achieve good functional results.

  13. Aerodynamics power consumption for mechanical flapping wings undergoing flapping and pitching motion

    Science.gov (United States)

    Razak, N. A.; Dimitriadis, G.; Razaami, A. F.

    2017-07-01

    Lately, due to the growing interest in Micro Aerial Vehicles (MAV), interest in flapping flight has been rekindled. The reason lies in the improved performance of flapping wing flight at low Reynolds number regime. Many studies involving flapping wing flight focused on the generation of unsteady aerodynamic forces such as lift and thrust. There is one aspect of flapping wing flight that received less attention. The aspect is aerodynamic power consumption. Since most mechanical flapping wing aircraft ever designed are battery powered, power consumption is fundamental in improving flight endurance. This paper reports the results of experiments carried out on mechanical wings under going active root flapping and pitching in the wind tunnel. The objective of the work is to investigate the effect of the pitch angle oscillations and wing profile on the power consumption of flapping wings via generation of unsteady aerodynamic forces. The experiments were repeated for different airspeeds, flapping and pitching kinematics, geometric angle of attack and wing sections with symmetric and cambered airfoils. A specially designed mechanical flapper modelled on large migrating birds was used. It will be shown that, under pitch leading conditions, less power is required to overcome the unsteady aerodnamics forces. The study finds less power requirement for downstroke compared to upstroke motion. Overall results demonstrate power consumption depends directly on the unsteady lift force.

  14. Single port-assisted fully laparoscopic abdominoperineal resection (APR) with immediate V-RAM flap reconstruction of the perineal defect.

    LENUS (Irish Health Repository)

    Ali, Sayid

    2012-09-01

    Abdominoperineal resection (APR) of anorectal cancers after neoadjuvant chemoradiotherapy may incur significant perineal morbidity. While vertical rectus abdominis muscle (V-RAM) flaps can fill the pelvic resection space with health tissue, their use has previously been described predominantly in association with laparotomy. Here, we describe a means of combination laparoscopic APR with V-RAM flap reconstruction that allows structural preservation of the entire abdominal wall throughout the oncological resection and of the deep parietal layers after V-RAM donation. Furthermore, a single port access device used at the end colostomy site allows a second senior surgeon assist with an additional two working instruments for the purpose of improved pelvic tissue retraction, especially useful in obese patients.

  15. Internal limiting membrane flap transposition for surgical repair of macular holes in primary surgery and in persistent macular holes.

    Science.gov (United States)

    Leisser, Christoph; Hirnschall, Nino; Döller, Birgit; Varsits, Ralph; Ullrich, Marlies; Kefer, Katharina; Findl, Oliver

    2018-03-01

    Classical or temporal internal limiting membrane (ILM) flap transposition with air or gas tamponade are current trends with the potential to improve surgical results, especially in cases with large macular holes. A prospective case series included patients with idiopathic macular holes or persistent macular holes after 23-G pars plana vitrectomy (PPV) and ILM peeling with gas tamponade. In all patients, 23-G PPV and ILM peeling with ILM flap transposition with gas tamponade and postoperative face-down position was performed. In 7 of 9 eyes, temporal ILM flap transposition combined with pedicle ILM flap could be successfully performed and macular holes were closed in all eyes after surgery. The remaining 2 eyes were converted to pedicle ILM flap transposition with macular hole closure after surgery. Three eyes were scheduled as pedicle ILM flap transposition due to previous ILM peeling. In 2 of these eyes, the macular hole could be closed with pedicle ILM flap transposition. In 3 eyes, free ILM flap transposition was performed and in 2 of these eyes macular hole could be closed after surgery, whereas in 1 eye a second surgery, performed as pedicle ILM flap transposition, was performed and led to successful macular hole closure. Use of ILM flaps in surgical repair of macular hole surgery is a new option of treatment with excellent results independent of the diameter of macular holes. For patients with persistent macular holes, pedicle ILM flap transposition or free ILM flap transposition are surgical options.

  16. PIV Measurements on a Blowing Flap

    Science.gov (United States)

    Hutcheson, Florence V.; Stead, Daniel J.

    2004-01-01

    PIV measurements of the flow in the region of a flap side edge are presented for several blowing flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main-element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the vortex system or accelerated the merging of the side vortex to the flap top surface. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

  17. Friction Pull Plug and Material Configuration for Anti-Chatter Friction Pull Plug Weld

    Science.gov (United States)

    Littell, Justin Anderson (Inventor)

    2016-01-01

    A friction pull plug is provided for use in forming a plug weld in a hole in a material. The friction pull plug includes a shank and a series of three frustoconical sections. The relative sizes of the sections assure that a central one of the sections defines the initial contact point between the hole's sides. The angle defined by the central one of the sections reduces or eliminates chatter as the plug is pulled into the hole.

  18. Recurrent, nonmalignant tracheoesophageal fistulas and the need for surgical improvisation.

    Science.gov (United States)

    Altorjay, Aron; Mucs, Mihály; Rüll, Miklós; Tihanyi, Zoltán; Hamvas, Balázs; Madácsy, László; Paál, Balázs

    2010-06-01

    Despite the many recent advances in thoracic surgery, the management of patients with recurrent, nonmalignant tracheoesophageal fistulas remains problematic, controversial, and challenging. Between 1998 and 2008, we treated 8 patients with RTEF. Closure of the original tracheoesophageal fistula had been attempted once in 5 patients, twice in 2 patients, and 4 times in 1 patient, all in different institutions. Four cases necessitated right posterolateral thoracotomy and cervical exposure, 2 cases cervical and abdominal incision, and 1 case right posterolateral thoracotomy, with abdominal and cervical exposure. With the exception of the 2 patients whose excluded esophagus was used to substitute for the trachea membranous wall, the damaged tracheal segment was removed. In general, a pedicled mediastinal pleural flap was pulled into the neck to increase the safety of the tracheal anastomosis formed with the trachea, and (or) to separate the suture lines of the two organs. A single intervention was sufficient for all 8 patients: no reoperation was necessary, and there was no perioperative mortality. Transient reflux, abdominal distention, and dyspnea in response to forced physical exertion occurred in 1 case each. Only 1 patient subsequently takes medication regularly for reflux disease. Separation initiated from the tracheal bifurcation, a pedicled mediastinal pleural flap pulled into the neck, a tracheal anastomosis sewn onto the cricoid cartilage with avoidance of its posterolateral elbow, a shaped Dumon stent (Novatech, Plan de Grasse, France) with an individually fenestrated tracheostomy cannula, and endoscopy-assisted, transhiatal vagal-preserving esophageal exclusion all served as successful elements of our surgical procedures. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Rescue of Primary Incomplete Microkeratome Flap with Secondary Femtosecond Laser Flap in LASIK

    Directory of Open Access Journals (Sweden)

    E. A. Razgulyaeva

    2014-01-01

    Full Text Available For laser-assisted in situ keratomileusis (LASIK retreatments with a previous unsuccessful mechanical microkeratome-assisted surgery, some surgical protocols have been described as feasible, such as relifting of the flap or the creation of a new flap and even the change to a surface ablation procedure (photorefractive keratectomy (PRK. This case shows the use of femtosecond technology for the creation of a secondary flap to perform LASIK in a cornea with a primary incomplete flap obtained with a mechanical microkeratome. As we were unable to characterize the interface of the first partial lamellar cut, a thick flap was planned and created using a femtosecond laser platform. As the primary cut was very thick in the nasal quadrant, a piece of loose corneal tissue appeared during flap lifting which was fitted in its position and not removed. Despite this condition and considering the regularity of the new femtosecond laser cut, the treatment was uneventful. This case report shows the relevance of a detailed corneal analysis with an advanced imaging technique before performing a secondary flap in a cornea with a primary incomplete flap. The femtosecond laser technology seems to be an excellent tool to manage such cases successfully.

  20. Innovation in the planning of V-Y rotation advancement flaps: A template for flap design

    Directory of Open Access Journals (Sweden)

    Utku Can Dölen

    2018-01-01

    Full Text Available Local flaps exhibit excellent color matching that no other type of flap can compete with. Moreover, surgery using a local flap is easier and faster than surgery using a distant or free flap. However, local flaps can be much more difficult to design. We designed 2 templates to plan a V-Y rotation advancement flap. The template for a unilateral V-Y rotation advancement flap was used on the face (n=5, anterior tibia (n=1, posterior axilla (n=1, ischium (n=1, and trochanter (n=2. The template for a bilateral flap was used on the sacrum (n=8, arm (n=1, and anterior tibia (n=1. The causes of the defects were meningocele (n=3, a decubitus ulcer (n=5, pilonidal sinus (n=3, and skin tumor excision (n=10. The meningocele patients were younger than 8 days. The mean age of the adult patients was 50.4 years (range, 19–80 years. All the donor areas of the flaps were closed primarily. None of the patients experienced wound dehiscence or partial/total flap necrosis. The templates guided surgeons regarding the length and the placement of the incision for a V-Y rotation advancement flap according to the size of the wound. In addition, they could be used for the training of residents.

  1. An experimental study of the unsteady vortex structures in the wake of a root-fixed flapping wing

    Science.gov (United States)

    Hu, Hui; Clemons, Lucas; Igarashi, Hirofumi

    2011-08-01

    An experimental study was conducted to characterize the evolution of the unsteady vortex structures in the wake of a root-fixed flapping wing with the wing size, stroke amplitude, and flapping frequency within the range of insect characteristics for the development of novel insect-sized nano-air-vehicles (NAVs). The experiments were conducted in a low-speed wing tunnel with a miniaturized piezoelectric wing (i.e., chord length, C = 12.7 mm) flapping at a frequency of 60 Hz (i.e., f = 60 Hz). The non-dimensional parameters of the flapping wing are chord Reynolds number of Re = 1,200, reduced frequency of k = 3.5, and non-dimensional flapping amplitude at wingtip h = A/C = 1.35. The corresponding Strouhal number (Str) is 0.33 , which is well within the optimal range of 0.2 flying insects and birds and swimming fishes for locomotion. A digital particle image velocimetry (PIV) system was used to achieve phased-locked and time-averaged flow field measurements to quantify the transient behavior of the wake vortices in relation to the positions of the flapping wing during the upstroke and down stroke flapping cycles. The characteristics of the wake vortex structures in the chordwise cross planes at different wingspan locations were compared quantitatively to elucidate underlying physics for a better understanding of the unsteady aerodynamics of flapping flight and to explore/optimize design paradigms for the development of novel insect-sized, flapping-wing-based NAVs.

  2. The Omental Pedicle Flap in Dogs Revised and Refined: A Cadaver Study.

    Science.gov (United States)

    Doom, Marjan; Cornillie, Pieter; Simoens, Paul; Huyghe, Stephanie; de Rooster, Hilde

    2016-08-01

    To expand current knowledge on the canine omental vasculature and refine the existing lengthening technique of the canine omentum. Ex vivo study. Canine cadavers (n=20). In 10 canine cadavers the omental arteries were mapped using intravascular latex injection and these results were used to create an omental pedicle flap based on the splenic artery in 10 additional cadavers. The operating range of the flap was recorded with particular attention to the main regions of interest for omental transposition in dogs (axillary and inguinal regions). The superficial and deep omental leaves were each predominantly supplied by a left and a right marginal omental artery that anastomosed near the caudal omental border into a superficial and a deep omental arch, respectively. Anastomoses between arteries of the superficial and the deep omental leaves were weak and inconsistent, except for 1 anastomosis that was found in 8 of 10 dogs. By transposing the intact omentum, the right axilla could be reached in 3 dogs, both axillae in 1 dog, and both groins in all cadavers. In all cases, the omental pedicle reached to and beyond the axillary and inguinal regions. By unfolding the pedicle leaves, the width of the pedicle tip could be doubled. When lengthening the omentum is necessary to reach extra-abdominal structures, the omental pedicle flap based on the splenic artery appears to preserve the omental vascular supply. These observations warrant further clinical trials to evaluate this new omtental flap technique in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.

  3. Navier-Stokes Computations of a Wing-Flap Model With Blowing Normal to the Flap Surface

    Science.gov (United States)

    Boyd, D. Douglas, Jr.

    2005-01-01

    A computational study of a generic wing with a half span flap shows the mean flow effects of several blown flap configurations. The effort compares and contrasts the thin-layer, Reynolds averaged, Navier-Stokes solutions of a baseline wing-flap configuration with configurations that have blowing normal to the flap surface through small slits near the flap side edge. Vorticity contours reveal a dual vortex structure at the flap side edge for all cases. The dual vortex merges into a single vortex at approximately the mid-flap chord location. Upper surface blowing reduces the strength of the merged vortex and moves the vortex away from the upper edge. Lower surface blowing thickens the lower shear layer and weakens the merged vortex, but not as much as upper surface blowing. Side surface blowing forces the lower surface vortex farther outboard of the flap edge by effectively increasing the aerodynamic span of the flap. It is seen that there is no global aerodynamic penalty or benefit from the particular blowing configurations examined.

  4. The Versatile Modiolus Perforator Flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Thomsen, Jorn Bo

    2016-01-01

    BACKGROUND: Perforator flaps are well established, and their usefulness as freestyle island flaps is recognized. The whereabouts of vascular perforators and classification of perforator flaps in the face are a debated subject, despite several anatomical studies showing similar consistency. In our...... experience using freestyle facial perforator flaps, we have located areas where perforators are consistently found. This study is focused on a particular perforator lateral to the angle of the mouth; the modiolus and the versatile modiolus perforator flap. METHODS: A cohort case series of 14 modiolus...... perforator flap reconstructions in 14 patients and a color Doppler ultrasonography localization of the modiolus perforator in 10 volunteers. RESULTS: All 14 flaps were successfully used to reconstruct the defects involved, and the location of the perforator was at the level of the modiolus as predicted...

  5. Cost-efficient demand-pull policies for multi-purpose technologies – The case of stationary electricity storage

    International Nuclear Information System (INIS)

    Battke, Benedikt; Schmidt, Tobias S.

    2015-01-01

    Highlights: • A definition of multi-purpose technologies (MPTs) is proposed. • Opportunities for a cost-efficient demand-pull policy strategy for MPTs are derived. • The multi-purpose character of stationary electricity storage (SES) is shown. • An exemplary profitability assessment of one SES technology supports the argument. - Abstract: Stationary electricity storage technologies (SES) allow to increase the shares of intermittent renewable energy technologies in electricity networks. As SES currently exhibit high costs, policy makers have started introducing demand-pull policies in order to foster their diffusion and drive these technologies further down the learning curve. However, as observed in the case of renewable energy technologies, demand-pull policies for technologies can come at high costs in cases where the profitability gap that needs to be covered by the policy support is large. Yet, SES can create value in multiple distinct applications in the power system – making it a “multi-purpose technology”. We argue that policy makers can make use of the multi-purpose character of SES to limit costs of demand-pull policies. We propose a policy strategy which grants support based on the profitability gap in the different applications, thereby moving down the learning curve efficiently. To support our argumentation, we firstly conduct a comprehensive literature review of SES applications exemplifying the multi-purpose character of these technologies. Second, we assess the profitability of one SES technology (vanadium redox flow battery) in five SES applications, highlighting a strong variation of the profitability gap across these applications

  6. MR imaging of the entry, the abdominal communicating orifice, and the retrograde dissection in aortic dissections

    International Nuclear Information System (INIS)

    Yoshida, Y.; Mukohara, N.; Nakamura, K.; Sugimura, K.; Kono, M.

    1986-01-01

    MR imaging (1.5 T) was performed on 41 patients with aortic dissection. Entries were clearly visualized on the MR images as partial defects of the intimal flap in 18 of 21 patients (85.7%). In eight of ten patients, the locations of abdominal communicating orifices corresponded to the lowest signal intensities of the false lumina. Retrograde disections were diagnosed in all six patients from gradual increases in signal intensities of the false lumina toward the heart. MR imaging was very useful in diagnosing entries of the thoracic aorta, abdominal communicating orifices between true and false lumina, and retrograde dissections

  7. Venous coupler use for free-flap breast reconstructions: specific analyses of TMG and DIEP flaps.

    Science.gov (United States)

    Bodin, Frédéric; Brunetti, Stefania; Dissaux, Caroline; Erik, A Sauleau; Facca, Sybille; Bruant-Rodier, Catherine; Liverneaux, Philippe

    2015-05-01

    The purpose of this report was to present the results of comparisons of anastomotic data and flap complications in the use of venous coupler in breast reconstruction with the transverse musculocutaneous gracilis (TMG) flap and the deep inferior epigastric perforator (DIEP) flap. Over a three-year period, 95 patients suffering from breast cancer were treated with mastectomy and breast reconstruction using free flaps. We performed 121 mechanical venous anastomoses for 105 flap procedures (80 DIEP and 25 TMG). The coupler size, anastomotic duration, number of anastomoses and postoperative complications were assessed for the entire series. The coupling device was perfectly suitable for all end-to-end anastomoses between the vein(s) of the flap and the internal mammary vein(s). No venous thrombosis occurred. The mean anastomotic time did not significantly differ between the DIEP (330 seconds) and TMG flap procedures (352 seconds) (P = 0.069). Additionally, there were no differences in coupling time observed following a comparison of seven coupler sizes (P = 0.066). The mean coupler size used during the TMG flap procedure was smaller than that used with the DIEP (2.4 mm versus 2.8 mm) (P TMG flap (28%) than with the DIEP flap (11%). The coupler size used was smaller for the TMG procedure and when double venous anastomosis was performed. Additionally, anastomotic time was not affected by the flap type or coupler size used or by anastomosis number. © 2014 Wiley Periodicals, Inc.

  8. Face resurfacing using a cervicothoracic skin flap prefabricated by lateral thigh fascial flap and tissue expander.

    Science.gov (United States)

    Li, Qingfeng; Zan, Tao; Gu, Bin; Liu, Kai; Shen, Guoxiong; Xie, Yun; Weng, Rui

    2009-01-01

    Resurfacing of facial massive soft tissue defect is a formidable challenge because of the unique character of the region and the limitation of well-matched donor site. In this report, we introduce a technique for using the prefabricated cervicothoracic skin flap for facial resurfacing, in an attempt to meet the principle of flap selection in face reconstructive surgery for matching the color and texture, large dimension, and thinner thickness (MLT) of the recipient. Eleven patients with massive facial scars underwent resurfacing procedures with prefabricated cervicothoracic flaps. The vasculature of the lateral thigh fascial flap, including the descending branch of the lateral femoral circumflex vessels and the surrounding muscle fascia, was used as the vascular carrier, and the pedicles of the fascial flap were anastomosed to either the superior thyroid or facial vessels in flap prefabrication. A tissue expander was placed beneath the fascial flap to enlarge the size and reduce the thickness of the flap. The average size of the harvested fascia flap was 6.5 x 11.7 cm. After a mean interval of 21.5 weeks, the expanders were filled to a mean volume of 1,685 ml. The sizes of the prefabricated skin flaps ranged from 12 x 15 cm to 15 x 32 cm. The prefabricated skin flaps were then transferred to the recipient site as pedicled flaps for facial resurfacing. All facial soft tissue defects were successfully covered by the flaps. The donor sites were primarily closed and healed without complications. Although varied degrees of venous congestion were developed after flap transfers, the marginal necrosis only occurred in two cases. The results in follow-up showed most resurfaced faces restored natural contour and regained emotional expression. MLT is the principle for flap selection in resurfacing of the massive facial soft tissue defect. Our experience in this series of patients demonstrated that the prefabricated cervicothoracic skin flap could be a reliable alternative

  9. Comparison of gluteal perforator flaps and gluteal fasciocutaneous rotation flaps for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chen, Yen-Chou; Huang, Eng-Yen; Lin, Pao-Yuan

    2014-03-01

    The gluteus maximus myocutaneous flap was considered the workhorse that reconstructed sacral pressure sores, but was gradually replaced by fasciocutaneous flap because of several disadvantages. With the advent of the perforator flap technique, gluteal perforator (GP) flap has gained popularity nowadays. The aim of this study was to compare the complications and outcomes between GP flaps and gluteal fasciocutaneous rotation (FR) flaps in the treatment of sacral pressure sores. Between April 2007 and June 2012, 63 patients underwent sacral pressure sore reconstructions, with a GP flap used in 31 cases and an FR flap used in 32 cases. Data collected on the patients included patient age, gender, co-morbidity for being bedridden and follow-up time. Surgical details collected included the defect size, operative time and estimated blood loss. Complications recorded included re-operation, dehiscence, flap necrosis, wound infection, sinus formation, donor-site morbidity and recurrence. The complications and clinical outcomes were compared between these two groups. We found that there was no significant difference in patient demographics, surgical complications and recurrence between these two groups. In gluteal FR flap group, all recurrent cases (five) were treated by reuse of previous flaps. Both methods are comparable, good and safe in treating sacral pressure sores. Gluteal FR flap can be performed without microsurgical dissection, and re-rotation is feasible in recurrent cases. The authors suggest using gluteal FR flaps in patients with a high risk of sore recurrence. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Investigación de seromas postliposucción y dermolipectomía abdominal Investigation about seromas in liposuction and abdominal dermolipectomy

    Directory of Open Access Journals (Sweden)

    E. Moretti

    2006-09-01

    Full Text Available El seroma es una de las complicaciones de los procedimientos estéticos de la pared abdominal. Este líquido contenido en el tejido celular subcutáneo y en el espacio supraaponeurótico es frecuente tema de discusión debido a que hay opiniones divergentes y contradictorias con respecto a los factores etiológicos, los elementos que contribuyen a su formación y a su tratamiento. El presente estudio de 2 años de duración, fue diseñado para investigar la incidencia de seromas en liposucciones y dermolipectomías abdominales aisladas, y cuando ambos procedimientos se realizan directamente en el colgajo abdominal. Se estudió esta complicación desde diferentes aspectos: experimental (15 conejos albinos de Nueva Zelanda, histopatológico y mediante análisis restropectivo en 60 casos. Se concluye, desde el punto de vista experimental, que los seromas son exudados. Su origen linfático se demostró por la presencia de linfangiectasias en las biopsias de los animales. El análisis retrospectivo de los casos clínicos y los resultados de laboratorio determinaron que cuando la dermolipectomía y liposucción se realizan en forma aislada el riesgo de desarrollar seromas es menor (13,04% que cuando ambos procedimientos se realizan juntos sobre el colgajo (50%. La aparición de células polimorfomucleares en el líquido indica la contaminación del seroma.Seroma is one of the complications of the aesthetic procedures in the abdominal wall. This fluid collected in the subcutaneous cellular tissue and in the supraaponeurotic space is a frequent subject of discussion since there are many divergent and contradictory opinions with regard to the etiologic factors and the elements that contribute in its formation and or its treatment. A two-year study was conducted to investigate incidence of seromas in liposuction and abdominal dermolipectomy and when both procedures was performed in the abdominal flap. We studied this complication from different aspects

  11. Experience with peroneus brevis muscle flaps for reconstruction of distal leg and ankle defects

    Directory of Open Access Journals (Sweden)

    Babu Bajantri

    2013-01-01

    Full Text Available Objective: Peroneus brevis is a muscle in the leg which is expendable without much functional deficit. The objective of this study was to find out its usefulness in coverage of the defects of the lower leg and ankle. Patients and Methods: A retrospective analysis of the use of 39 pedicled peroneus brevis muscle flaps used for coverage of defects of the lower leg and ankle between November 2010 and December 2012 was carried out. The flaps were proximally based for defects of the lower third of the leg in 12 patients and distally based for reconstruction of defects of the ankle in 26 patients, with one patient having flaps on both ankles. Results: Partial flap loss in critical areas was found in four patients requiring further flap cover and in non-critical areas in two patients, which were managed with a skin graft. Three of the four critical losses occurred when we used it for covering defects over the medial malleolus. There was no complete flap loss in any of the patients. Conclusion: This flap has a unique vascular pattern and fails to fit into the classification of the vasculature of muscles by Mathes and Nahai. The unusual feature is an axial vessel system running down the deep aspect of the muscle and linking the perforators from the peroneal artery and anterior tibial artery, which allows it to be raised proximally or distally on a single perforator. The flap is simple to raise and safe for the reconstruction of small-to moderate-sized skin defects of the distal third of the tibia and all parts of the ankle except the medial malleolus, which is too far from the pedicle of the distally based flap. The donor site can be closed primarily to provide a linear scar. The muscle flap thins with time to provide a good result aesthetically at the primary defect.

  12. Management of Vortices Trailing Flapped Wings via Separation Control

    Science.gov (United States)

    Greenblatt, David

    2005-01-01

    A pilot study was conducted on a flapped semi-span model to investigate the concept and viability of near-wake vortex management via separation control. Passive control was achieved by means of a simple fairing and active control was achieved via zero mass-flux blowing slots. Vortex sheet strength, estimated by integrating surface pressure ports, was used to predict vortex characteristics by means of inviscid rollup relations. Furthermore, vortices trailing the flaps were mapped using a seven-hole probe. Separation control was found to have a marked effect on vortex location, strength, tangential velocity, axial velocity and size over a wide range of angles of attack and control conditions. In general, the vortex trends were well predicted by the inviscid rollup relations. Manipulation of the separated flow near the flap edges exerted significant control over both outboard and inboard edge vortices while producing negligible lift excursions. Dynamic separation and attachment control was found to be an effective means for dynamically perturbing the vortex from arbitrarily long wavelengths down to wavelengths less than a typical wingspan. In summary, separation control has the potential for application to time-independent or time-dependent wake alleviation schemes, where the latter can be deployed to minimize adverse effects on ride-quality and dynamic structural loading.

  13. Comparison of Dorsal Intercostal Artery Perforator Propeller Flaps and Bilateral Rotation Flaps in Reconstruction of Myelomeningocele Defects.

    Science.gov (United States)

    Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar

    2018-04-09

    Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.

  14. The Pedicled Buccal Fat Pad: Anatomical Study of the New Flap for Skull Base Defect Reconstruction After Endoscopic Endonasal Transpterygoid Surgery

    Science.gov (United States)

    Golbin, Denis A.; Lasunin, Nikolay V.; Cherekaev, Vasily A.; Polev, Georgiy A.

    2016-01-01

    Objectives To evaluate the efficacy and safety of using a buccal fat pad for endoscopic skull base defect reconstruction. Design Descriptive anatomical study with an illustrative case presentation. Setting Anatomical study was performed on 12 fresh human cadaver specimens with injected arteries (24 sides). Internal carotid artery was exposed in the coronal plane via the endoscopic transpterygoid approach. The pedicled buccal fat pad was used for reconstruction. Participants: 12 human cadaver head specimens; one patient operated using the proposed technique. Main outcome measures: Proximity of the buccal fat pad flap to the defect, compliance of the flap, comfort and safety of harvesting procedure, and compatibility with the Hadad–Bassagasteguy nasoseptal flap. Results: Harvesting procedure was performed using anterior transmaxillary corridor. The pedicled buccal fat pad flap can be used to pack the sphenoid sinus or cover the internal carotid artery from cavernous to upper parapharyngeal segment. Conclusion The buccal fat pad can be safely harvested through the same approach without external incisions and is compliant enough to conform to the skull base defect. The proposed pedicled flap can replace free abdominal fat in central skull base reconstruction. The volume of the buccal fat pad allows obliteration of the sphenoid sinus or upper parapharyngeal space. PMID:28180047

  15. Systematic review and meta-analysis of enterocolitis after one-stage transanal pull-through procedure for Hirschsprung's disease.

    LENUS (Irish Health Repository)

    Ruttenstock, Elke

    2012-02-01

    PURPOSE: The transanal one-stage pull-through procedure (TERPT) has gained worldwide popularity over open and laparoscopic-assisted one-stage techniques in children with Hirschsprung\\'s disease (HD). It offers the advantages of avoiding laparotomy, laparoscopy, scars, abdominal contamination, and adhesions. However, enterocolitis associated with Hirschsprung\\'s disease (HAEC) still remains to be a potentially life-threatening complication after pull-through operation. The reported incidence of HAEC ranges from 4.6 to 54%. This meta-analysis was designed to evaluate postoperative incidence of HAEC following TERPT procedure. METHODS: A meta-analysis of cases of TERPT reported between 1998 and 2009 was performed. Detailed information was recorded regarding intraoperative details and postoperative complications with particular emphasis on incidence of HAEC. Diagnosis of HAEC in a HD patient was based on the clinical presentation of diarrhoea, abdominal distension, and fever. RESULTS: Of the 54 published articles worldwide, 27 articles, including 899 patients were identified as reporting entirely TERPT procedure. Postoperative HAEC occurred in 92 patients (10.2%). Recurrent episodes of HAEC were reported in 18 patients (2%). Conservative treatment of HAEC was successful in 75 patients (81.5%), whereas in 17 patients (18.5%) surgical treatment was needed. CONCLUSIONS: This systematic review reveals that TERPT is a safe and less-invasive procedure with a low incidence of postoperative HAEC.

  16. Pull-pull position control of dual motor wire rope transmission.

    Science.gov (United States)

    Guo, Quan; Jiao, Zongxia; Yan, Liang; Yu, Qian; Shang, Yaoxing

    2016-08-01

    Wire rope transmission is very efficient because of the small total moving object mass. The wire rope could only transmit pulling force. Therefore it has to be kept in a tightened state during transmission; in high speed applications the dynamic performance depends on the rope's stiffness, which can be adjusted by the wire rope tension. To improve the system dynamic performance output, this paper proposes a novel pull-pull method based on dual motors connected by wire ropes, for precise, high speed position control applications. The method can regulate target position and wire rope tension simultaneously. Wire ropes remain in a pre-tightening state at all times, which prevents the influence of elasticity and reduces the position tracking error in the changing direction process. Simulations and experiments were conducted; the results indicate that both position precision and superior dynamic performance can be synchronously achieved. The research is relevant to space craft precision pointing instruments.

  17. Total endoscopic free flap harvest of a serratus anterior fascia flap for microsurgical lower leg reconstruction

    Directory of Open Access Journals (Sweden)

    Erdmann, Alfons

    2014-04-01

    Full Text Available [english] Background: A tremendous number of free flaps have been developed in the past. As the surgical result depends not only on a successful flap transfer but also on the harvest, this paper details the procedures for undertaking the first total endoscopic harvest of a serratus fascia flap for free flap transplantation to the lower leg. Patient and methods: In September 2012 we performed the first total endoscopic serratus anterior fascia free flap harvest. The incision of 2.5 cm length was made 10 cm in front of anterior muscle border of the latissimus dorsi at level with the midthorax. After insertion of a flexible laparoscopic single port system we started CO gas insufflation. We used this setting to meticulously prepare a neo cavity between atissimus dorsi and M. serratus anterior. The vessels were dissected and the thoraco-dorsal nerve was separated. With a second auxiliary incision we used a clamp to support the raising of the fascia flap from the underlying muscle. Finally we clipped the vessels to the latissimus dorsi muscle and the flap vessels at the Arteria and Vena axillaris. The flap was extracted via the 2.5 cm incision.Results: We were able to perform a total endoscopic harvest of a serratus fascia flap for free flap reconstruction of soft tissues. With this new operative technique we were able to avoid a long skin incision, which in our view lowers the morbidity at the harvest area.Conclusion: We describe a new method for the total endoscopic harvest of the serratus fascia flap for free flap transfer. The flap was harvested within reasonable time and following surgery leaves the patient with minimal donor site morbidity compared to the open technique.

  18. Propeller Flaps: A Literature Review.

    Science.gov (United States)

    Sisti, Andrea; D'Aniello, Carlo; Fortezza, Leonardo; Tassinari, Juri; Cuomo, Roberto; Grimaldi, Luca; Nisi, Giuseppe

    2016-01-01

    Since their introduction in 1991, propeller flaps are increasingly used as a surgical approach to loss of substance. The aim of this study was to evaluate the indications and to verify the outcomes and the complication rates using this reconstructing technique through a literature review. A search on PubMed was performed using "propeller flap", "fasciocutaneous flap", "local flap" or "pedicled flap" as key words. We selected clinical studies using propeller flaps as a reconstructing technique. We found 119 studies from 1991 to 2015. Overall, 1,315 propeller flaps were reported in 1,242 patients. Most frequent indications included loss of substance following tumor excision, repair of trauma-induced injuries, burn scar contractures, pressure sores and chronic infections. Complications were observed in 281/1242 patients (22.6%) occurring more frequently in the lower limbs (31.8%). Partial flap necrosis and venous congestion were the most frequent complications. The complications' rate was significantly higher in infants (70 years old) but there was not a significant difference between the sexes. Trend of complication rate has not improved during the last years. Propeller flaps showed a great success rate with low morbidity, quick recovery, good aesthetic outcomes and reduced cost. The quality and volume of the transferred soft tissue, the scar orientation and the possibility of direct donor site closure should be considered in order to avoid complications. Indications for propeller flaps are small- or medium-sized defects located in a well-vascularized area with healthy surrounding tissues. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  19. Staged abdominal closure with intramuscular tissue expanders and modified components separation technique of a giant incisional hernia after repair of a ruptured omphalocele

    Directory of Open Access Journals (Sweden)

    Yukihiro Tatekawa

    2016-07-01

    Full Text Available In patients with omphalocele, several different techniques are performed for repair of the abdominal wall defect. We present the case of a staged abdominal closure of a giant incisional hernia after repair of a ruptured omphalocele. At birth, skin flap coverage associated with silo formation occurred, but the abdominal wall defect remained, resulting in a giant abdominal hernia. To expand the layers of the abdominal wall, tissue expanders were placed between the bilateral internal oblique and transverses abdominis muscles. Postoperatively, a modified components separation technique was performed. The abdominal wall was closed in the midline. Upon closure of the skin in the midline, bilateral relaxing incisions were performed, covering the remaining defect with artificial dermis. At the age of one year and 7 months, the patient had no recurrent incisional hernia nor any wound complications.

  20. The freestyle pedicle perforator flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Jackson, Ian T; Westvik, Tormod S

    2015-01-01

    BACKGROUND: Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally...... not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. METHODS: We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled...... perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects...

  1. Pulled elbow in children.

    Science.gov (United States)

    Yamanaka, Syunsuke; Goldman, Ran D

    2018-06-01

    Question Our practice is seeing children with relatively minor injuries to their elbows, with a history of "swinging" them when their hands are being held to cross the road. Nothing is usually found on a physical examination. I know that this is likely a "pulled elbow." Can we manage this in the clinic setting rather than sending the family to the emergency department? What would be the best course of action in the clinic setting? Answer Pulled elbow, also called nursemaid's elbow , is a radial head subluxation caused by axial traction or a sudden pull of the extended pronated arm, and it is a very common phenomenon. The practice of swinging children while holding their hands should be abandoned. In the case of pulled elbow, the child usually avoids moving the affected arm, holding it close to his or her body, without considerable pain, and no obvious swelling or deformity can be seen. While a fracture should be excluded, pulled elbow can usually be identified based on this presentation. The reduction procedure can easily be done in the office setting, with an 80% success rate and no complications. The hyperpronation maneuver (holding the elbow at 90° and then firmly pronating the wrist) to reduce pulled elbow has been found to be better than a supination-flexion maneuver (holding the elbow at 90° with one hand, supinating and flexing the elbow rapidly with the other) and should be exercised first. When 2 trials of reduction are unsuccessful, the child's arm should be splinted and the family should be sent for further evaluation. Copyright© the College of Family Physicians of Canada.

  2. Optimal propulsive flapping in Stokes flows.

    Science.gov (United States)

    Was, Loïc; Lauga, Eric

    2014-03-01

    Swimming fish and flying insects use the flapping of fins and wings to generate thrust. In contrast, microscopic organisms typically deform their appendages in a wavelike fashion. Since a flapping motion with two degrees of freedom is able, in theory, to produce net forces from a time-periodic actuation at all Reynolds numbers, we compute in this paper the optimal flapping kinematics of a rigid spheroid in a Stokes flow. The hydrodynamics for the force generation and energetics of the flapping motion is solved exactly. We then compute analytically the gradient of a flapping efficiency in the space of all flapping gaits and employ it to derive numerically the optimal flapping kinematics as a function of the shape of the flapper and the amplitude of the motion. The kinematics of optimal flapping are observed to depend weakly on the flapper shape and are very similar to the figure-eight motion observed in the motion of insect wings. Our results suggest that flapping could be a exploited experimentally as a propulsion mechanism valid across the whole range of Reynolds numbers.

  3. Optimal propulsive flapping in Stokes flows

    International Nuclear Information System (INIS)

    Was, Loïc; Lauga, Eric

    2014-01-01

    Swimming fish and flying insects use the flapping of fins and wings to generate thrust. In contrast, microscopic organisms typically deform their appendages in a wavelike fashion. Since a flapping motion with two degrees of freedom is able, in theory, to produce net forces from a time-periodic actuation at all Reynolds numbers, we compute in this paper the optimal flapping kinematics of a rigid spheroid in a Stokes flow. The hydrodynamics for the force generation and energetics of the flapping motion is solved exactly. We then compute analytically the gradient of a flapping efficiency in the space of all flapping gaits and employ it to derive numerically the optimal flapping kinematics as a function of the shape of the flapper and the amplitude of the motion. The kinematics of optimal flapping are observed to depend weakly on the flapper shape and are very similar to the figure-eight motion observed in the motion of insect wings. Our results suggest that flapping could be a exploited experimentally as a propulsion mechanism valid across the whole range of Reynolds numbers. (paper)

  4. [A variant of island flaps for the covering of pressure sores: the hatchet flap. Apropos of 31 cases].

    Science.gov (United States)

    Quillot, M; Lodde, J P; Pegorier, O; Reynaud, J P; Cormerais, A

    1994-08-01

    The authors propose a modification of the classical design of island flaps for cover of pressure sores, applied to gluteus maximus and tensor fascia lata muscles: the hatchet flap. 31 flaps have been used including 13 gluteus maximus superior flaps for sacral pressure sores, 9 gluteal inferior flaps for ischial pressure sores and 9 tensor fascia lata flaps for trochanteric pressure sores. A small partial necrosis and two cases of sepsis were observed in this series, but did not require surgical revision. The authors emphasize the value of this modification of the classical flap design, which preserves an even better musculocutaneous capital in these patients, who are often already multi-operated. The very rapid recovery of patients supports the authors' application of hatchet flaps to the surgery of pressure sores, and suggests the extension to other musculocutaneous flaps in the future.

  5. Self-Induced Backaction Optical Pulling Force

    Science.gov (United States)

    Zhu, Tongtong; Cao, Yongyin; Wang, Lin; Nie, Zhongquan; Cao, Tun; Sun, Fangkui; Jiang, Zehui; Nieto-Vesperinas, Manuel; Liu, Yongmin; Qiu, Cheng-Wei; Ding, Weiqiang

    2018-03-01

    We achieve long-range and continuous optical pulling in a periodic photonic crystal background, which supports a unique Bloch mode with the self-collimation effect. Most interestingly, the pulling force reported here is mainly contributed by the intensity gradient force originating from the self-induced backaction of the object to the self-collimation mode. This force is sharply distinguished from the widely held conception of optical tractor beams based on the scattering force. Also, this pulling force is insensitive to the angle of incidence and can pull multiple objects simultaneously.

  6. Power performance optimization and loads alleviation with active flaps using individual flap control

    DEFF Research Database (Denmark)

    Pettas, Vasilis; Barlas, Athanasios; Gertz, Drew Patrick

    2016-01-01

    the sensor inputs. The AEP is increased due to the upscaling but also further due to the flap system while the fatigue loads in components of interest (blade, tower, nacelle and main bearing) are reduced close to the level of the original turbine. The aim of this study is to demonstrate a simple....... In an industrial-oriented manner the baseline rotor is upscaled by 5% and the ATEFs are implemented in the outer 30% of the blades. The flap system is kept simple and robust with a single flap section and control with wind speed, rotor azimuth, root bending moments and angle of attack in flap's mid-section being...

  7. [Aesthetic effect of wound repair with flaps].

    Science.gov (United States)

    Tan, Qian; Zhou, Hong-Reng; Wang, Shu-Qin; Zheng, Dong-Feng; Xu, Peng; Wu, Jie; Ge, Hua-Qiang; Lin, Yue; Yan, Xin

    2012-08-01

    To investigate the aesthetic effect of wound repair with flaps. One thousand nine hundred and ninety-six patients with 2082 wounds hospitalized from January 2004 to December 2011. These wounds included 503 deep burn wounds, 268 pressure sores, 392 soft tissue defects caused by trauma, 479 soft tissue defects due to resection of skin cancer and mole removal, 314 soft tissue defects caused by scar excision, and 126 other wounds. Wound area ranged from 1.5 cm x 1.0 cm to 30.0 cm x 22.0 cm. Sliding flaps, expanded flaps, pedicle flaps, and free flaps were used to repair the wounds in accordance with the principle and timing of wound repair with flaps. Five flaps showed venous congestion within 48 hours post-operation, 2 flaps of them improved after local massage. One flap survived after local heparin wet packing and venous bloodletting. One flap survived after emergency surgical embolectomy and bridging with saphenous vein graft. One flap showed partial necrosis and healed after skin grafting. The other flaps survived well. One thousand three hundred and twenty-one patients were followed up for 3 months to 2 years, and flaps of them were satisfactory in shape, color, and elasticity, similar to that of normal skin. Some patients underwent scar revision later with good results. Application of suitable flaps in wound repair will result in quick wound healing, good function recovery, and satisfactory aesthetic effect.

  8. Laser resurfacing of skin flaps: an experimental comparison

    Directory of Open Access Journals (Sweden)

    Srdan Babovic

    2011-05-01

    Full Text Available Objective. The influence of Coherent Ultrapulse, TruPulse and Erbium: YAG laser skin resurfacing on survival of the skin flaps when performed simultaneously was evaluated. Material and methods. We used twelve female Yucatan minipigs in the study. Skin flaps including paniculus carnosus were raised on the animals’ back. The flaps were sutured into the defect under tension. We designed 4 experimental groups: Control-Flaps only, Group 2-Flaps + 4 immediate TruPulse laser passes, Group 3-Flaps + 2 immediate Coherent UltraPulse laser passes, Group 4-Flaps – immediate 50J/cm2 total fluence with Erbium: YAG laser. Results. Flap survival in Control group was 98.8%. There was no flap in Group 2 with complete survival. Survival of the flaps in Group 2 (Tru-Pulse ranged from 75-90%, with average flap survival area of 85.2%. In Group 3 (UltraPulse all 24 flaps had some area of necrosis. Flap survival in Group 3 ranged from 75-95%, with an average of 85.6%. In Group 4 (Erbium: YAG flap survival area ranged from 70-95%, with all 24 flaps with some area of necrosis, with average flap survival area of 87.3%. There is a significant statistical difference in flap survival area between groups 2, 3 and 4 versus Control (p<0.001. Conclusion. The results of our study suggest that laser resurfacing of skin flaps sutured under tension in the same operative session is detrimental for skin flap survival. We also found no significant difference in flap survival area between TruPulse, Coherent UltraPulse and Erbium: YAG laser treated flaps.

  9. Propeller TAP flap

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Bille, Camilla; Wamberg, Peter

    2013-01-01

    major complications needing additional surgery. One flap was lost due to a vascular problem. Breast reconstruction can be performed by a propeller TAP flap without cutting the descending branch of the thoracodorsal vessels. However, the authors would recommend that a small cuff of muscle is left around...

  10. Active Control of Long Bridges Using Flaps

    DEFF Research Database (Denmark)

    Hansen, H. I.; Thoft-Christensen, Palle

    The main problem in designing ultra-long span suspension bridges is flutter. A solution to this problem might be to introduce an active flap control system to increase the flutter wind velocity. The investigated flap control system consists of flaps integrated in the bridge girder so each flap...... is the streamlined part of the edge of the girder. Additional aerodynamic derivatives are shown for the flaps and it is shown how methods already developed can be used to estimate the flutter wind velocity for a bridge section with flaps. As an example, the flutter wind velocity is calculated for different flap...... configurations for a bridge section model by using aerodynamic derivatives for a flat plate. The example shows that different flap configurations can either increase or decrease the flutter wind velocity. for optimal flap configurations flutter will not occur....

  11. Treatment of ischial pressure sores with both profunda femoris artery perforator flaps and muscle flaps.

    Science.gov (United States)

    Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun; Lee, Won Jai

    2014-07-01

    Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  12. Treatment of Ischial Pressure Sores with Both Profunda Femoris Artery Perforator Flaps and Muscle Flaps

    Directory of Open Access Journals (Sweden)

    Chae Min Kim

    2014-07-01

    Full Text Available Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50% had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years. The mean follow-up period was 27.9 months (range, 3-57 months. In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%, wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%, but resolved with conservative treatment. Among 16 cases, there was only one (6% recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.

  13. Foot placement strategy in pushing and pulling.

    Science.gov (United States)

    Lee, Tzu-Hsien

    2018-01-01

    Pushing and pulling tasks are very common in daily and industrial workplaces. They are one major source of musculoskeletal complaints. This study aimed to examine the foot placement strategy while pushing and pulling. Thirteen young males and ten young females were recruited as participants. A two (pushing and pulling) by four (48 cm, 84 cm, 120 cm, and 156 cm) factorial design was used. Exertion direction and exertion height significantly affected foot placement strategy. Pushing task needed more anteroposterior space than pulling task. The percentages of female/male for trailing foot position ranged from 77% to 90% (pushing) and from 80% to 93% (pulling) across the exertion heights. Practitioners should provide an anteroposterior space approximately to 70% body stature for workers to exert their maximum pulling and pushing strengths.

  14. Free Boomerang-shaped Extended Rectus Abdominis Myocutaneous flap: The longest possible skin/myocutaneous free flap for soft tissue reconstruction of extremities.

    Science.gov (United States)

    Koul, Ashok R; Nahar, Sushil; Prabhu, Jagdish; Kale, Subhash M; Kumar, Praveen H P

    2011-09-01

    A soft tissue defect requiring flap cover which is longer than that provided by the conventional "long" free flaps like latissimus dorsi (LD) and anterolateral thigh (ALT) flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free "Boomerang-shaped" Extended Rectus Abdominis Myocutaneous (BERAM) flap. This flap is the slightly modified and "free" version of a similar flap described by Ian Taylor in 1983. This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs.

  15. DIEP flap customization using Fluobeam® indocyanine green tissue perfusion assessment with large previous abdominal scar

    Directory of Open Access Journals (Sweden)

    Michael A. Fallucco

    2017-06-01

    Full Text Available The Fluobeam® is a portable, near-infrared camera that is held and controlled by the surgeon to visualize tissue perfusion using indocyanine green (ICG fluorescence imaging. This case report describes how data obtained from ICG imaging allows intraoperative customization in a previously surgically scarred abdomen during autologous Deep Inferior Epigastric Artery Perforator (DIEP flap bilateral breast reconstruction. The outcome was successful breast mound recreation without fat necrosis.

  16. Chimeric superficial temporal artery based skin and temporal fascia flap plus temporalis muscle flap - An alternative to free flap for suprastructure maxillectomy with external skin defect

    Directory of Open Access Journals (Sweden)

    Dushyant Jaiswal

    2011-01-01

    Full Text Available Flaps from temporal region have been used for mid face, orbital and peri-orbital reconstruction. The knowledge of the vascular anatomy of the region helps to dissect and harvest the muscle/fascia/skin/combined tissue flaps from that region depending upon the requirement. Suprastructure maxillectomy defects are usually covered with free flaps to fill the cavity. Here we report an innovative idea in which a patient with a supra structure maxillectomy with external skin defect was covered with chimeric flap based on the parietal and frontal branches of superficial temporal artery and the temporalis muscle flap based on deep temporal artery.

  17. Is a pulling sensation in the anteroposterior direction associated with otolith dysfunction?

    Science.gov (United States)

    Saka, Naoki; Seo, Toru; Ohta, Shigeto; Sakagami, Masafumi

    2014-03-01

    A pulling sensation in the anteroposterior direction is suggested to originate from a dysfunction of the otolith organs. Previous study with vestibular evoked myogenic potential (VEMP) confirmed that a falling sensation (in an up or down direction) and a lateral tilt sensation (in a right or left direction) were caused by otolith lesions. The purpose of this study was to clarify whether a pulling sensation in the anteroposterior (forward or backward) direction originates from otolith dysfunction. The otolith function was assessed by cervical and ocular VEMPs (cVEMPs and oVEMPs) in 12 patients who complained of a forward or backward pulling sensation. cVEMPs were evaluated by the asymmetry ratio (AR) of the amplitude of the p13-n23 wave and the peak latencies of the p13 and n23 waves. oVEMPs were evaluated by the AR of the amplitude of the n1-p1 wave and the peak latency of the n1 and p1 waves. Abnormal ARs on cVEMP were observed in 7 of 12 patients. Nine of 12 patients had abnormal oVEMP results including 3 bilateral absent responses. Most (10 of 12) patients had abnormal cVEMP and/or oVEMP results. The latency of each detected wave was within the normal ranges.

  18. Successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia: A rare case report.

    Science.gov (United States)

    Liu, Yu; Wang, Yi-Feng

    2017-07-01

    We report a case of successful vaginal delivery after vaginal reconstruction with labium minus flaps in a 23-year-old patient with congenital vaginal atresia. The patient primarily presented with amenorrhea and cyclic abdominal pain; transabdominal ultrasonography revealed an enlarged uterus due to hematometra and absence of the lower segment of the vagina. Eight years ago, she had undergone an unsuccessful attempt at canalization at a local hospital. Upon referral to our hospital, she underwent vaginal reconstruction with labium minus flaps. Four months after this procedure, she became pregnant and, subsequently, successfully and safely vaginally delivered a healthy female baby weighing 3250 g at 38 +1 weeks' gestation. The delivery did not involve perineal laceration by lateral episiotomy. To the best of our knowledge, this is the first reported case of successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia. © 2017 Japan Society of Obstetrics and Gynecology.

  19. Free Boomerang-shaped Extended Rectus Abdominis Myocutaneous flap: The longest possible skin/myocutaneous free flap for soft tissue reconstruction of extremities

    Directory of Open Access Journals (Sweden)

    Ashok R Koul

    2011-01-01

    Full Text Available Background: A soft tissue defect requiring flap cover which is longer than that provided by the conventional "long" free flaps like latissimus dorsi (LD and anterolateral thigh (ALT flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free "Boomerang-shaped" Extended Rectus Abdominis Myocutaneous (BERAM flap. This flap is the slightly modified and "free" version of a similar flap described by Ian Taylor in 1983. Materials and Methods: This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Results: Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. Conclusion: BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs.

  20. Non-slipping domains of a pulled spool

    International Nuclear Information System (INIS)

    Wagner, Clemens; Vaterlaus, Andreas

    2014-01-01

    We have investigated the pulled spool by considering pulling angles up to 360 ∘ . Our focus was on downward pulling forces with pulling angles in the range of 180 ∘ to 360 ∘ . In this range we have found a domain of pulling angles where the spool never starts to slip independent of the strength of the pulling force. The size of the domain depends on the static friction coefficient and on the moment of inertia of the spool. The non-slipping domain is mainly formed around the critical angle where the static friction force becomes zero. For low static friction the non-slipping domain decays into two different domains. We have determined the limiting angles of the non-slipping domains and explored the transitions from a single domain to two separated domains in parameter space. (paper)

  1. Anatomical basis of the lateral superior gluteal artery perforator (LSGAP) flap and role in bilateral breast reconstruction.

    Science.gov (United States)

    Fade, Geraldine; Gobel, Fabienne; Pele, Eric; Chaput, Benoit; Garrido, Ignacio; Pinsolle, Vincent; Pelissier, Philippe; Sinna, Raphael

    2013-06-01

    Deep inferior epigastric perforator (DIEP) flap is one of the gold standards in autologous breast reconstruction. When the abdominal tissue is not available, the superior gluteal artery perforator (SGAP) is often a second option with its drawback, especially the donor-site deformity. Reports have highlighted that a higher and more lateral SGAP flap can be harvested to overcome several drawbacks of the classical SGAP, allowing in the same procedure a body-contouring procedure. In order to set the anatomical basis of this flap, we proposed to study the characteristics of a reliable and easily identifiable superior and lateral perforator of the superior gluteal artery (lateral SGAP (LSGAP)) situated in the region of the lower body-lift resection allowing to perform bilateral breast reconstruction at the same time. The anatomical study of 50 scans (or 100 buttocks) allows us to set forth a diagnostic assumption on the localisation of the perforator with respect to osseous landmarks (coccyx, iliac crest and great trochanter) which will be verified during the dissection of 10 cadavers (or 20 buttocks) and during the 20 colour Doppler examination (or 40 buttocks). In our computed tomography (CT) scan study, in 96% of cases, the perforator was situated in a circle with a radius≤3 cm with a 95% confidence interval and located at the junction of the proximal third-middle third of the distance summit of the posterior iliac crest (point B), most lateral point of the greater trochanter (point C). This assumption was verified by the cadaveric dissection and in vivo studies. Our study sets the anatomical landmarks of the LSGAP flap. This option allows the raising of an SGAP flap avoiding the main drawbacks of this flap and allows harvesting a flap with the tissue that is often discarded during the body-lift procedure. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Cost-effectiveness of monitoring free flaps.

    Science.gov (United States)

    Subramaniam, Shiva; Sharp, David; Jardim, Christopher; Batstone, Martin D

    2016-06-01

    Methods of free flap monitoring have become more sophisticated and expensive. This study aims to determine the cost of free flap monitoring and examine its cost effectiveness. We examined a group of patients who had had free flaps to the head and neck over a two-year period, and combined these results with costs obtained from business managers and staff. There were 132 free flaps with a success rate of 99%. The cost of monitoring was Aus $193/flap. Clinical monitoring during this time period cost Aus$25 476 and did not lead to the salvage of any free flaps. Cost equivalence is reached between monitoring and not monitoring only at a failure rate of 15.8%. This is to our knowledge the first study to calculate the cost of clinical monitoring of free flaps, and to examine its cost-effectiveness. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  3. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats.

    Science.gov (United States)

    Sá, Jairo Zacchê de; Aguiar, José Lamartine de Andrade; Cruz, Adriana Ferreira; Schuler, Alexandre Ricardo Pereira; Lima, José Ricardo Alves de; Marques, Olga Martins

    2012-12-01

    To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005), 1 and 4 (p=0.024), 2 and 3 (p=0.003), 2 and 4 (p=0.001). These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.

  4. Solar cell contact pull strength as a function of pull-test temperature

    Science.gov (United States)

    Yasui, R. K.; Berman, P. A.

    1972-01-01

    Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.

  5. Effects of irradiation of skin flaps

    International Nuclear Information System (INIS)

    Sumi, Y.; Ueda, M.; Oka, T.; Torii, S.

    1984-01-01

    The reaction of skin flaps to irradiation and the optimum postoperative time for irradiation was studied in the rat. Flaps showed different reactions depending on the time of irradiation. There was a correlation between the radiosensitivity and the vascularity of the flap. Those flaps in the marginal hypovascular stage of revascularization showed reactions similar to normal skin. However, severe adverse reactions were observed in the marginal hypervascular stage

  6. Flap Lymphedema after Successful Reconstruction of the Chronic Inguinal Wound with a Vertical Rectus Abdominis Flap (VRAM

    Directory of Open Access Journals (Sweden)

    Yalcin Kulahci

    2012-07-01

    Full Text Available The reconstruction of extensive and complex wounds represents a challenging problem for reconstructive surgeon. The reconstructive options to provide cover-age following debridment of these complicated wounds are local, distant flaps, or freetissue transfer. Vertical rectus abdominis flaps have been used succes-sully to repair defects in the groin, hip, perineal, trunk, and breast regions. We encountered flap lymphedema after successful reconstruction of the chronic in-guinal wound with a vertical rectus abdominis (VRAM flap. As far as were able to ascertain, there is no report in the literature related to flap lymphedema.

  7. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap.

    Science.gov (United States)

    Hekner, Dominique D; Abbink, Jan H; van Es, Robert J; Rosenberg, Antoine; Koole, Ronald; Van Cann, Ellen M

    2013-08-01

    Donor-site morbidity following harvest of the radial forearm free flap was compared with that following harvest of the ulnar forearm free flap. Twenty-eight radial forearm and 27 ulnar forearm flaps were harvested in 55 patients with head and neck defects. Pressure perception was measured with Semmes-Weinstein monofilaments. Cold perception was tested with chloroethyl. Donor-site healing was evaluated. Patients were interviewed about grip and pinch strength and donor-site appearance. In the radial forearm free flap group, pressure perception and cold perception were reduced in the donor hand, whereas in the ulnar group, no differences were observed between the donor and unoperated hands. In the radial forearm group, 15 percent of patients experienced reduced strength in the donor hand, whereas in the ulnar forearm group, none of the patients reported reduced strength in the donor hand. In the radial forearm group, 14 percent had partial or complete loss of the skin graft, whereas in the ulnar forearm group, 4 percent had partial loss of the skin graft. In the radial forearm group, 18 percent of patients were dissatisfied with the appearance of the donor site, and no complaints were reported in the ulnar forearm group. The authors' study shows less donor site-morbidity following harvest of the ulnar forearm free flap than following harvest of the radial forearm free flap. These results emphasize that the ulnar forearm free flap should be considered as an alternative for the radial forearm free flap for reconstruction of soft-tissue defects. Therapeutic, III.

  8. Development of a morphing flap using shape memory alloy actuators: the aerodynamic characteristics of a morphing flap

    International Nuclear Information System (INIS)

    Ko, Seung-Hee; Bae, Jae-Sung; Rho, Jin-Ho

    2014-01-01

    The discontinuous contour of a wing with conventional flaps diminishes the aerodynamic performance of an aircraft. A wing with a continuous contour does not experience extreme flow stream fluctuations during flight, and consequently has good aerodynamic characteristics. In this study, a morphing flap using shape memory alloy actuators is proposed, designed and fabricated, and its aerodynamic characteristics are investigated using aerodynamic analyses and wind tunnel tests. The ribs of the morphing flap are designed and fabricated with multiple elements joined together in a way that allows relative rotations of adjacent elements and forms a smooth contour of the morphing flap. The aerodynamic analyses of this multiple-element morphing-flap wing are performed using XFLR pro; its aerodynamic performance is compared with that of a mechanical-flap wing, and is measured through wind-tunnel tests. (papers)

  9. Median forehead flap - beyond classic indication

    Directory of Open Access Journals (Sweden)

    Cristian R. Jecan

    2016-11-01

    Full Text Available Introduction. The paramedian forehead flap is one of the best options for reconstruction of the median upper two-thirds of the face due to its vascularity, color, texture match and ability to resurface all or part of the reconstructed area. The forehead flap is the gold standard for nasal soft tissue reconstruction and the flap of choice for larger cutaneous nasal defects having a robust pedicle and large amount of tissue. Materials and Methods. We are reporting a clinical series of cutaneous tumors involving the nose, medial canthus, upper and lower eyelid through a retrospective review of 6 patients who underwent surgical excision of the lesion and primary reconstruction using a paramedian forehead flap. Results. The forehead flap was used for total nose reconstruction, eyelids and medial canthal reconstruction. All flaps survived completely and no tumor recurrence was seen in any of the patients. Cosmetic and functional results were favorable. Conclusions. The forehead flap continues to be one of the best options for nose reconstruction and for closure of surgical defects of the nose larger than 2 cm. Even though is not a gold standard, median forehead flap can be an advantageous technique in periorbital defects reconstruction.

  10. Hyperbaric oxygen therapy and surgical delay improve flap survival of reverse pedicle flaps for lower third leg and foot reconstruction

    Directory of Open Access Journals (Sweden)

    Pradeoth Mukundan Korambayil

    2015-06-01

    Full Text Available Aim: The purpose of the study is to present a management protocol for various types of soft tissue defects of the distal third region of leg and foot treated with pedicle flaps, by including hyperbaric oxygen (HBO therapy in the treatment regimen with flap delay. Methods: We present a prospective study of 23 patients with various types of soft tissue defects of the foot, and lower third of leg managed in our institution from December 2012 to December 2013. All soft tissue defects were treated by a reverse pedicle flap. Twelve patients were managed with flap delay with HBO therapy and 11 patients with immediate flaps without HBO therapy. The postoperative period, hospital course, and follow-up were documented. Results: Of 12 patients with flap delay and HBO, 10 patients did not suffer any complications secondary to flap transfer. One patient had discoloration of the tip of the flap, which settled without the intervention, and 1 patient had recurrent abscess formation, which required debridement and closure. Of 11 patients with direct transfer, 6 patients presented with complications including flap congestion, partial flap loss, and tip necrosis, which required secondary intervention. Conclusion: HBO therapy is a useful adjunct in flap delay of the reverse pedicle flap for soft tissue reconstruction of the lower third of the leg and foot regions.

  11. The Temporalis Muscle Flap in Maxillofacial Reconstruction

    International Nuclear Information System (INIS)

    ElSheikh, M; Zeitoun, I; ElMassry, M A K

    1991-01-01

    The temporalis muscle flap is a very versatile and valuable axial flap, which could be used in various reconstructive procedures in and around the oro-maxillofacial region. The surgical anatomy, vascular pattern and technique of elevation of the flap are described, together with our experience in different reconstructive situations. The advantages and disadvantages of the use of this flap are thoroughly discussed taking into consideration the potentiality of cancer recurrence under cover of the flap. (author)

  12. Tensor fascia lata flap versus tensor fascia lata perforator-based island flap for the coverage of extensive trochanteric pressure sores.

    Science.gov (United States)

    Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon

    2013-06-01

    Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.

  13. PushPull++

    KAUST Repository

    Lipp, Markus; Wonka, Peter; Mü ller, Pascal

    2014-01-01

    PushPull tools are implemented in most commercial 3D modeling suites. Their purpose is to intuitively transform a face, edge, or vertex, and then to adapt the polygonal mesh locally. However, previous approaches have limitations: Some allow

  14. Rate-determining Step of Flap Endonuclease 1 (FEN1) Reflects a Kinetic Bias against Long Flaps and Trinucleotide Repeat Sequences.

    Science.gov (United States)

    Tarantino, Mary E; Bilotti, Katharina; Huang, Ji; Delaney, Sarah

    2015-08-21

    Flap endonuclease 1 (FEN1) is a structure-specific nuclease responsible for removing 5'-flaps formed during Okazaki fragment maturation and long patch base excision repair. In this work, we use rapid quench flow techniques to examine the rates of 5'-flap removal on DNA substrates of varying length and sequence. Of particular interest are flaps containing trinucleotide repeats (TNR), which have been proposed to affect FEN1 activity and cause genetic instability. We report that FEN1 processes substrates containing flaps of 30 nucleotides or fewer at comparable single-turnover rates. However, for flaps longer than 30 nucleotides, FEN1 kinetically discriminates substrates based on flap length and flap sequence. In particular, FEN1 removes flaps containing TNR sequences at a rate slower than mixed sequence flaps of the same length. Furthermore, multiple-turnover kinetic analysis reveals that the rate-determining step of FEN1 switches as a function of flap length from product release to chemistry (or a step prior to chemistry). These results provide a kinetic perspective on the role of FEN1 in DNA replication and repair and contribute to our understanding of FEN1 in mediating genetic instability of TNR sequences. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. Tubularized Penile-Flap Urethroplasty Using a Fasciocutaneous Random Pedicled Flap for Recurrent Anterior Urethral Stricture

    Directory of Open Access Journals (Sweden)

    Yong Jig Lee

    2012-05-01

    Full Text Available This report describes the use of a tubularized random flap for the curative treatment of recurrent anterior urethral stricture. Under the condition of pendulous lithotomy and suprapubic cystostomy, the urethral stricture was removed via a midline ventral penile incision followed by elevation of the flap and insertion of an 18-Fr catheter. Subcutaneous buried interrupted sutures were used to reapproximate the waterproof tubularized neourethra and to coapt with the neourethra and each stump of the urethra, first proximally and then distally. The defect of the penile shaft was covered by advancement of the surrounding scrotal flap. The indwelling catheter was maintained for 21 days. A 9 month postoperative cystoscopy showed no flap necrosis, no mechanical stricture, and no hair growth on the lumen of the neourethra. The patient showed no voiding discomfort 6 months after the operation. The advantages of this procedure are the lack of need for microsurgery, shortening of admission, the use of only spinal anesthesia (no general anesthesia, and a relatively short operative time. The tubularized unilateral penile fasciocutaneous flap should be considered an option for initial flap urethroplasty as a curative technique.

  16. Reconstruction of the Lower Extremity Using Free Flaps

    Directory of Open Access Journals (Sweden)

    Min Jo Kang

    2013-09-01

    Full Text Available Background The aim of lower-extremity reconstruction has focused on wound coverage andfunctional recovery. However, there are limitations in the use of a local flap in cases of extensivedefects of the lower-extremities. Therefore, free flap is a useful option in lower-extremityreconstruction.Methods We performed a retrospective review of 49 patients (52 cases who underwentlower-extremity reconstruction at our institution during a 10-year period. In these patients,we evaluated causes and sites of defects, types of flaps, recipient vessels, types of anastomosis,survival rate, and complications.Results There were 42 men and 10 women with a mean age of 32.7 years (range, 3-72years. The sites of defects included the dorsum of the foot (19, pretibial area (17, ankle(7, heel (5 and other sites (4. The types of free flap included latissimus dorsi muscle flap(10, scapular fascial flap (6, anterolateral thigh flap (6, and other flaps (30. There werefour cases of vascular complications, out of which two flaps survived after intervention. Theoverall survival of the flaps was 96.2% (50/52. There were 19 cases of other complications atrecipient sites such as partial graft loss (8, partial flap necrosis (6 and infection (5. However,these complications were not notable and were resolved with skin grafts.Conclusions The free flap is an effective method of lower-extremity reconstruction. Goodoutcomes can be achieved with complete debridement and the selection of appropriaterecipient vessels and flaps according to the recipient site.

  17. Free flap reconstruction for diabetic foot limb salvage.

    Science.gov (United States)

    Sato, Tomoya; Yana, Yuichiro; Ichioka, Shigeru

    2017-12-01

    Although free flap is gaining popularity for the reconstruction of diabetic foot ulcers, it is unclear whether free flap reconstruction increases the chances of postoperative independent ambulation. The aim of this study is to evaluate the relationship between free flap success and postoperative ambulation. This study reviewed 23 cases of free flap reconstruction for diabetic foot ulcers between January 2007 and March 2014. Free rectus abdominis, latissimus dorsi, and anterolateral thigh flaps were used in ten, eight, and five patients, respectively. A comparison was made between free flap success and postoperative independent ambulation using Fisher's exact test. Two patients developed congestive heart failure with fatal consequences within 14 days postoperatively, resulting in an in-hospital mortality rate of 8.7%. Five patients lost their flaps (21.7%). Of the 16 patients who had flap success, 12 achieved independent ambulation. Five patients with flap loss did not achieve independent ambulation, except one patient who underwent secondary flap reconstruction using a distally based sural flap. Fisher's exact test revealed that independent ambulation was associated with free flap success (p = 0.047). The present study indicates that free flap reconstruction may increase the possibility of independent ambulation for patients with extensive tissue defects due to diabetic ulcers. Intermediate limb salvage rates and independent ambulation rates were favourable in patients with successful reconstruction. The use of foot orthoses and a team approach with pedorthists were effective to prevent recurrence.

  18. Use if a soecuak sokubt ub reverse syrak artery flap to reduce venous congestion and flap necrosis

    International Nuclear Information System (INIS)

    Masood, T.; Ahmed, R.; Obaidullah, M.

    2016-01-01

    Background: Distally based sural fascio-cutaneous flap is a commonly performed plastic surgery procedure for the coverage of distal third of leg, ankle and foot defects. However congestion is the main complication of this flap which results into partial or complete loss of the flap. We devised a special splint to reduce this complication and retrospectively reviewed its effect on this complication between two groups. Methods: This retrospective study was carried out at Northwest General hospital between 1995 and 2012. Group-A included 30 patients who were managed without the splint between 1995 and 2005 and group B comprised of 35 patients were treated with the splint between 2006 and 2012. Complications like venous congestion, epidermolysis, and partial and complete flap failure were documented. Data were analyzed by SPSS.16.5 software. Chi- square test was used for data analysis. P value less than 0.05 was considered as the level of significance. Results: Total 65 patients were operated. Age of the patients ranged from 7 to 60 years. Road traffic accident and spoke wheel injury was the main cause of soft tissue loss in our patients. In group A 12 patients suffered from venous congestion. Out of 12, three patients had epidermolysis while partial flap necrosis occurred in 9 patients. Only 3 patients had venous congestion in group B. Two patients suffered from epidermolysis and one had partial flap necrosis. None of patient suffered from complete flap loss in both groups. Conclusion: Reverse sural artery flap continues to be a versatile flap for distal lower extremity reconstruction. By using a special splint to reduce pressure on the pedicle site as a modification, flap complication rate can be decreased significantly. (author)

  19. Use of the Anterolateral Thigh and Vertical Rectus Abdominis Musculocutaneous Flaps as Utility Flaps in Reconstructing Large Groin Defects

    Directory of Open Access Journals (Sweden)

    Edwin Jonathan Aslim

    2014-09-01

    Full Text Available BackgroundGroin dissections result in large wounds with exposed femoral vessels requiring soft tissue coverage, and the reconstructive options are diverse. In this study we reviewed our experience with the use of the pedicled anterolateral thigh and vertical rectus abdominis musculocutaneous flaps in the reconstruction of large groin wounds.MethodsGroin reconstructions performed over a period of 10 years were evaluated, with a mean follow up of two years. We included all cases with large or complex (involving perineum defects, which were reconstructed with the pedicled anterolateral thigh musculocutaneous or the vertical rectus abdominis musculocutaneous (VRAM flaps. Smaller wounds which were covered with skin grafts, locally based flaps and pedicled muscle flaps were excluded.ResultsTwenty-three reconstructions were performed for large or complex groin defects, utilising the anterolateral thigh (n=10 and the vertical rectus abdominis (n=13 pedicled musculocutaneous flaps. Femoral vein reconstruction with a prosthetic graft was required in one patient, and a combination flap (VRAM and gracilis muscle flap was performed in another. Satisfactory coverage was achieved in all cases without major complications. No free flaps were used in our series.ConclusionsThe anterolateral thigh and vertical rectus abdominis pedicled musculocutaneous flaps yielded consistent results with little morbidity in the reconstruction of large and complex groin defects. A combination of flaps can be used in cases requiring extensive cover.

  20. Identification of Flap Motion Parameters for Vibration Reduction in Helicopter Rotors with Multiple Active Trailing Edge Flaps

    Directory of Open Access Journals (Sweden)

    Uğbreve;ur Dalli

    2011-01-01

    Full Text Available An active control method utilizing the multiple trailing edge flap configuration for rotorcraft vibration suppression and blade loads control is presented. A comprehensive model for rotor blade with active trailing edge flaps is used to calculate the vibration characteristics, natural frequencies and mode shapes of any complex composite helicopter rotor blade. A computer program is developed to calculate the system response, rotor blade root forces and moments under aerodynamic forcing conditions. Rotor blade system response is calculated using the proposed solution method and the developed program depending on any structural and aerodynamic properties of rotor blades, structural properties of trailing edge flaps and properties of trailing edge flap actuator inputs. Rotor blade loads are determined first on a nominal rotor blade without multiple active trailing edge flaps and then the effects of the active flap motions on the existing rotor blade loads are investigated. Multiple active trailing edge flaps are controlled by using open loop controllers to identify the effects of the actuator signal output properties such as frequency, amplitude and phase on the system response. Effects of using multiple trailing edge flaps on controlling rotor blade vibrations are investigated and some design criteria are determined for the design of trailing edge flap controller that will provide actuator signal outputs to minimize the rotor blade root loads. It is calculated that using the developed active trailing edge rotor blade model, helicopter rotor blade vibrations can be reduced up to 36% of the nominal rotor blade vibrations.

  1. Burn Scar Reconstruction of the Neck with FTSG Obtained from Lower Abdominal Skin

    Directory of Open Access Journals (Sweden)

    Sadrollah Motamed

    2011-05-01

    Full Text Available Burns account for a significant proportion of injuries, and of these the face, neck, and anterior torso are commonly affected. Burn scars remain a lasting reminder of the insult both for the patient and the outside world. There is little doubt that the change in appearance and the limitation imposed by a burn scar contribute to negative body image. Treatment of hypertrophic scars in the neck has been quite challenging if there is no intact tissue for local flaps. So application of full-thickness skin grafts could be of great value. We applied full-thickness grafts obtained from lower abdominal skin for treatment of severe neck contractures in four patients when other treatment modalities such as local flaps could not be used. Full-thickness skin graft of the neck is a safe and reliable treatment option with fairly good functional and aesthetic results. It has little donor site morbidity in spite of providing a large surface area of full-thickness skin.

  2. August A. Pulle. 1878-1955

    NARCIS (Netherlands)

    Lanjouw, J.

    1955-01-01

    On the 28th of February 1955 Prof. Dr A. A. Pulle died at Utrecht after a long and painful illness. August Adriaan Pulle was born on the 10th of January 1878 at Arnhem, where he also attended the primary and the secundary school. During the later years at the high school his interest in plants was

  3. Energy management - The delayed flap approach

    Science.gov (United States)

    Bull, J. S.

    1976-01-01

    Flight test evaluation of a Delayed Flap approach procedure intended to provide reductions in noise and fuel consumption is underway using the NASA CV-990 test aircraft. Approach is initiated at a high airspeed (240 kt) and in a drag configuration that allows for low thrust. The aircraft is flown along the conventional ILS glide slope. A Fast/Slow message display signals the pilot when to extend approach flaps, landing gear, and land flaps. Implementation of the procedure in commercial service may require the addition of a DME navigation aid co-located with the ILS glide slope transmitter. The Delayed Flap approach saves 250 lb of fuel over the Reduced Flap approach, with a 95 EPNdB noise contour only 43% as large.

  4. Reconstruction of the Lower Extremity Using Free Flaps

    Directory of Open Access Journals (Sweden)

    Min Jo Kang

    2013-09-01

    Full Text Available BackgroundThe aim of lower-extremity reconstruction has focused on wound coverage and functional recovery. However, there are limitations in the use of a local flap in cases of extensive defects of the lower-extremities. Therefore, free flap is a useful option in lower-extremity reconstruction.MethodsWe performed a retrospective review of 49 patients (52 cases who underwent lower-extremity reconstruction at our institution during a 10-year period. In these patients, we evaluated causes and sites of defects, types of flaps, recipient vessels, types of anastomosis, survival rate, and complications.ResultsThere were 42 men and 10 women with a mean age of 32.7 years (range, 3-72 years. The sites of defects included the dorsum of the foot (19, pretibial area (17, ankle (7, heel (5 and other sites (4. The types of free flap included latissimus dorsi muscle flap (10, scapular fascial flap (6, anterolateral thigh flap (6, and other flaps (30. There were four cases of vascular complications, out of which two flaps survived after intervention. The overall survival of the flaps was 96.2% (50/52. There were 19 cases of other complications at recipient sites such as partial graft loss (8, partial flap necrosis (6 and infection (5. However, these complications were not notable and were resolved with skin grafts.ConclusionsThe free flap is an effective method of lower-extremity reconstruction. Good outcomes can be achieved with complete debridement and the selection of appropriate recipient vessels and flaps according to the recipient site.

  5. [COMPARISON OF REPAIR EFFECT BETWEEN CHIMERIC ANTEROLATERAL THIGH FLAP AND SERIES-WOUND FLAPS FOR DEFECT AFTER RESECTION OF ORAL AND MAXILLOFACIAL CANCER].

    Science.gov (United States)

    Yang, Heping; Zhang, Hongwu; Chen, Haidi; Yang, Shuxiong; Wang, Jun; Hu, Dawang

    2016-04-01

    To compare the effectiveness of complex defects repair between using chimeric anterolateral thigh flap and series-wound flaps after resection of oral and maxillofacial cancer. After resection of oral and maxillofacial cancer, defect was repaired with chimeric anterolateral thigh flap in 39 patients between January 2011 and July 2014 (chimeric anterolateral thigh flap group); and defect was repaired with series-wound flaps in 35 patients between January 2009 and December 2010 (series-wound flaps group). There was no significant difference in gender, age, duration of disease, tumor type, tumor staging, defect location, and defect area between 2 groups (P > 0.05). The operation time, flap harvesting and microvascular anastomosis time, stomach tube extraction time, and oral feeding time were recorded and compared between 2 groups, and postoperative complications were observed; the effectiveness was evaluated according to clinical efficacy evaluation table of bone and soft tissue defects reconstruction surgery in oral and maxillofacial region. Vascular crisis occurred in 2 cases of chimeric anterolateral thigh flap group, and 4 cases of series-wound flaps group. Partial necrosis appeared at distal end of a series-wound flaps, and oral fistula and infection developed in 3 series-wound flaps. The other flaps and the grafted skin at donor site survived; wounds at recipient site healed by first intention. The operation time, stomach tube extraction time, and oral feeding time of chimeric anterolateral thigh flap group were significantly shorter than those of series-wound flaps group (P oral closure function, chew, language performance, and swallowing scores of the chimeric anterolateral thigh-flap group were significantly better than those of the series-wound flaps group (P oral cavity holding water test, and occlusion scores between the 2 groups (P > 0.05). Using chimeric anterolateral thigh flap for defect repair after resection of oral and maxillofacial cancer can

  6. Using Metaheuristic and Fuzzy System for the Optimization of Material Pull in a Push-Pull Flow Logistics Network

    Directory of Open Access Journals (Sweden)

    Afshin Mehrsai

    2013-01-01

    Full Text Available Alternative material flow strategies in logistics networks have crucial influences on the overall performance of the networks. Material flows can follow push, pull, or hybrid systems. To get the advantages of both push and pull flows in networks, the decoupling-point strategy is used as coordination mean. At this point, material pull has to get optimized concerning customer orders against pushed replenishment-rates. To compensate the ambiguity and uncertainty of both dynamic flows, fuzzy set theory can practically be applied. This paper has conceptual and mathematical parts to explain the performance of the push-pull flow strategy in a supply network and to give a novel solution for optimizing the pull side employing Conwip system. Alternative numbers of pallets and their lot-sizes circulating in the assembly system are getting optimized in accordance with a multi-objective problem; employing a hybrid approach out of meta-heuristics (genetic algorithm and simulated annealing and fuzzy system. Two main fuzzy sets as triangular and trapezoidal are applied in this technique for estimating ill-defined waiting times. The configured technique leads to smoother flows between push and pull sides in complex networks. A discrete-event simulation model is developed to analyze this thesis in an exemplary logistics network with dynamics.

  7. Innervated boomerang flap for finger pulp reconstruction.

    Science.gov (United States)

    Chen, Shao-Liang; Chiou, Tai-Fung

    2007-11-01

    The boomerang flap originates from the dorsolateral aspect of the proximal phalanx of an adjacent digit and is supplied by the retrograde blood flow through the vascular arcades between the dorsal and palmar digital arteries. To provide sensation of the boomerang flap for finger pulp reconstruction, the dorsal sensory branch of the proper digital nerve and the superficial sensory branch of the corresponding radial or ulnar nerve are included within the skin flap. After transfer of the flap to the injured site, epineural neurorrhaphies are done between the digital nerves of the pulp and the sensory branches of the flap. We used this sensory flap in five patients, with more than 1 year follow-up, and all patients achieved measurable two-points discrimination. The boomerang flap not only preserves the proper palmar digital artery but also provides an extended and innervated skin paddle. It seems to be an alternative choice for one-stage reconstruction of major pulp defect.

  8. Reconstruction of Facial Defect Using Deltopectoral Flap.

    Science.gov (United States)

    Aldelaimi, Tahrir N; Khalil, Afrah A

    2015-11-01

    Reconstruction of the head and neck is a challenge for otolarygology surgeons, maxillofacial surgeons as well as plastic surgeons. Defects caused by the resection and/or trauma should be closed with flaps which match in color, texture and hair bearing characteristics with the face. Deltopectoral flap is a one such flap from chest and neck skin mainly used to cover the facial defects. This study report a patient presenting with tragic Road Traffic Accident (RTA) admitted to maxillofacial surgery department at Ramadi Teaching Hospital, Anbar province, Iraq. An incision, medially based, was done and deltopectoral fascio-cutaneous flap was used for surgical exposure and closure of defects after RTA. There was no major complication. Good aesthetic and functional results were achieved. Deltopectoral flap is an excellent alternative for the reconstruction of head and neck. Harvesting and application of the flap is rapid and safe. Only a single incision is sufficient for dissection and flap elevation.

  9. Refining the intrinsic chimera flap: a review.

    Science.gov (United States)

    Agarwal, Jayant P; Agarwal, Shailesh; Adler, Neta; Gottlieb, Lawrence J

    2009-10-01

    Reconstruction of complex tissue deficiencies in which each missing component is in a different spatial relationship to each other can be particularly challenging, especially in patients with limited recipient vessels. The chimera flap design is uniquely suited to reconstruct these deformities. Chimera flaps have been previously defined in many ways with 2 main categories: prefabricated or intrinsic. Herein we attempt to clarify the definition of a true intrinsic chimeric flap and provide examples of how these constructs provide a method for reconstruction of complex defects. The versatility of the intrinsic chimera flap and its procurement from 7 different vascular systems is described. A clarification of the definition of a true intrinsic chimera flap is described. In addition, construction of flaps from the lateral femoral circumflex, deep circumflex iliac, inferior gluteal, peroneal, subscapular, thoracodorsal, and radial arterial systems is described to showcase the versatility of these chimera flaps. A true intrinsic chimera flap must consist of more than a single tissue type. Each of the tissue components receives its blood flow from separate vascular branches or perforators that are connected to a single vascular source. These vascular branches must be of appropriate length to allow for insetting with 3-dimensional spatial freedom. There are a multitude of sites from which true intrinsic chimera flaps may be harvested.

  10. The role of postoperative hematoma on free flap compromise.

    Science.gov (United States)

    Ahmad, Faisal I; Gerecci, Deniz; Gonzalez, Javier D; Peck, Jessica J; Wax, Mark K

    2015-08-01

    Hematomas may develop in the postoperative setting after free tissue transfer. When hematomas occur, they can exert pressure on surrounding tissues. Their effect on the vascular pedicle of a free flap is unknown. We describe our incidence of hematoma in free flaps and outcomes when the flap is compromised. Retrospective chart review of 1,883 free flaps performed between July 1998 and June 2014 at a tertiary referral center. Patients with free flap compromise due to hematoma were identified. Etiology, demographic data, and outcomes were evaluated. Eighty-eight (4.7%) patients developed hematomas. Twenty (22.7%) of those had flap compromise. Twelve compromises (60%) showed evidence of pedicle thrombosis. The salvage rate was 75% versus 54% in 79 flaps with compromise from other causes (P = .12). Mean time to detection of the hematoma was 35.3 hours in salvaged flaps compared to 91.6 hours in unsalvageable flaps (P = .057). Time to operating room (OR) from detection was 2.8 hours in salvageable flaps compared to 12.4 hours in nonsalvageable flaps (P = .053). The salvage rate for flaps that returned to the OR in hematomas developed rarely. When they did, 23% went on to develop flap compromise. Prompt recognition and re-exploration allowed for a high salvage rate. Vessel thrombosis predicted inability to salvage the flap. 4 © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  11. An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions

    NARCIS (Netherlands)

    Hummelink, S.L.; Verhulst, A.C.; Maal, T.J.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Ulrich, D.J.O.

    2017-01-01

    BACKGROUND: Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available

  12. STRENGTH ANALYSIS METHODS OF CIRCULAR PULL BROACH COGS

    Directory of Open Access Journals (Sweden)

    Cosmin MIRIŢOIU

    2010-10-01

    Full Text Available A very big importance in a pull broach designing is represented by its mechanic computation, which trots out the pull broach resistance on various blank tooling, pull broach productivity and also the loadings which is subdued to and the stresses that appear during the chipping process. The pull broach geometric complexity leads to one difficulty concerning the resistance computing methods application (and implicitly, simplifying assumptions application. This present study presents a resistance computing of pull broach cogs, which dresses a circular hole trotting out more methods which can be used in this computing, and the teoretic aspects are then trotted out by an example of a numerical computation for a particular case.

  13. Elbow Reconstruction Using Island Flap for Burn Patients

    Directory of Open Access Journals (Sweden)

    Gi Yeun Hur

    2012-11-01

    Full Text Available BackgroundDeep burns of the elbow lead to soft tissue necrosis and infection, with exposure of deep structures. Adequate wound coverage of this area requires thin, pliable, and durable tissue, while optimal functional recovery requires early coverage and functional rehabilitation. We have found 3 types of island flaps that provide reliable coverage for the elbow.MethodsA retrospective study was performed on all patients who underwent flap coverage of an elbow defect at our hospital. The patients' data including age, sex, cause of injury, wound dimensions, timing of flap coverage, postoperative elbow motion, and complications were investigated.ResultsBetween 2001 and 2012, 16 patients were treated at our hospital. The mean age was 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral arm flaps, and 4 radial forearm flaps. The average defect size was 183.5 cm2 (range, 28 to 670 cm2. Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days. The mean postoperative active elbow flexion was 98° (range, 85° to 115°. Partial flap failure occurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%, hematoma (23.5%, seroma (35.3%, and wound infection (5.9%.ConclusionsFlap selection for elbow reconstruction is determined by the defect size and the extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a single-staged, reliable, and relatively simple procedure that permits initiation of early rehabilitation, thereby improving a patient's functional outcome.

  14. Customized Pull Systems for Single-Product Flow Lines

    NARCIS (Netherlands)

    Gaury, E.G.A.; Kleijnen, J.P.C.; Pierreval, H.

    1998-01-01

    Traditionally pull production systems are managed through classic control systems such as Kanban, Conwip, or Base stock, but this paper proposes ‘customized’ pull control. Customization means that a given production line is managed through a pull control system that in principle connects each stage

  15. Retention of a reconstructed nipple using a C-V flap with different layer thicknesses in the C-flap.

    Science.gov (United States)

    Sowa, Yoshihiro; Itsukage, Sizu; Sakaguchi, Kouichi; Taguchi, Tetsuya; Numajiri, Toshiaki

    2018-04-01

    The C-V flap for nipple reconstruction is now one of standard surgical techniques. But decreased projection is still a problem. In recent years, it has been suggested that projection can be more easily maintained when raising of the C-flap is performed with a split thickness dermis. In this study, we examined whether decrease of projection can be prevented by raising of a C-flap with a split dermis rather than with full dermis. A total of 49 consecutive patients who underwent reconstruction of a nipple using the C-V flap technique were enrolled. The patients included 22 who underwent surgery using a C-flap with a full thickness dermis (Group F), and 27 who underwent surgery with raising of a flap with a split thickness dermis (Group S). The size of the reconstructed nipple was measured at 2 weeks, 6 months and 1 year postoperatively for comparison between Groups F and S. Partial necrosis of the C-flap end occurred in 4 subjects in only Group S. The decrease in projection after 1 year postoperatively in Group S was significantly lower than that in Group F. In contrast, the teat base size in Group F tended to be greater than that in Group S, suggesting a tendency for an expanded base using a flap with a full dermis. Our results indicated that it is recommended to use a C-flap with a split dermis for cases with high projection of the nipple on the contralateral side.

  16. Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.

    Science.gov (United States)

    Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng

    2015-07-01

    Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.

  17. Import-push or Export-pull?

    DEFF Research Database (Denmark)

    Jäkel, Ina Charlotte

    2014-01-01

    predictions regarding the export market and the role of product differentiation. Empirical results for a sample of Danish manufacturing industries confirm the import- "push" hypothesis as well as the export- "pull" hypothesis, but also reveal differences across industries. The selection effect of trade...... is mainly driven by the "import-push" if product differentiation is high, whereas it is driven by the "export-pull" if goods are homogeneous....

  18. Import-push or Export-pull?

    DEFF Research Database (Denmark)

    Jäkel, Ina Charlotte

    predictions regarding the export market and the role of product differentiation. Empirical results for a sample of Danish manufacturing industries confirm the import-"push" hypothesis as well as the export-"pull" hypothesis, but also reveal differences across industries. The selection effect of trade...... is mainly driven by the "import-push" if product differentiation is high, whereas it is driven by the "export-pull" if goods are homogeneous....

  19. Energy requirements of tire pulling.

    Science.gov (United States)

    Fredriksen, Per M; Mamen, Asgeir

    2017-10-01

    We have investigated the effect using walking poles and pulling tires at 4 and 6 km·h-1 (1.11 and 1.67 m·s-1) speeds on oxygen uptake (V̇O2) and heart rate. Eleven subjects, 6 males, with a mean (SD) age of 25.2 (6.9) years participated in field tests involving walking without poles, walking with poles and tire pulling with poles. Increasing the load caused the largest increases in energy demand, more than 4 MET. Speed increase also caused substantial energy increase, approximately 4 MET. Increasing the inclination only modestly increased the oxygen uptake, approximately 2 MET. In both level walking and uphill walking, using poles marginally increased oxygen uptake compared to working without poles. Pulling one tire (12.5 kg) required an oxygen uptake of 27 (4) mL·kg-1·min-1 at 4 km·h-1 and 0% inclination. Adding one more tire (6 kg) drove the oxygen uptake further up to 39 (4) mL·kg-1·min-1. This is close to the requirement of level running at 10.5 km·h-1. Pulling both tires at 6 km·h-1 and 5% inclination required a V̇O2 of 54 (6) mL·kg-1·min-1, equal to running uphill at 5% inclination and 12.5 km·h-1 speed. Heart rate rose comparably with oxygen uptake. At 4 km·h-1 and 0% inclination the increase was 29 bpm, from 134 (21) to 163 (22) bpm when going from pulling one tire to two tires. In the hardest exercise, 6 km·h-1 and 5% inclination, heart rate reached 174 (14) bpm. The study showed that tire pulling even at slow speeds has an energy requirement that is so large that the activity may be feasible as endurance training.

  20. Modified cup flap for volar oblique fingertip amputations

    Directory of Open Access Journals (Sweden)

    Ahmadli, A.

    2016-02-01

    Full Text Available We describe a modified volar “V-Y cup” flap for volar fingertip defects that do not exceed more than half of the distal phalanx for better aesthetic and functional outcome. In seven cases out of eight, the flap was elevated with a subdermal pedicle, whereas in one case, the flap was elevated as an island on the bilateral neurovascular bundle. The fingertips have been evaluated for sensibility using standard tests, hook nail deformity and patient satisfaction. Seven flaps have survived completely. The flap with skeletonized bilateral digital neurovascular bundle has shown signs of venous insufficiency on the 5 postoperative day with consecutive necrosis. Suturing the distal edges of the flap in a “cupping” fashion provided a normal pulp contour. The modified flap can be used for defects as mentioned above. Subdermally dissected pedicle-based flap is safe and easy to elevate. The aesthetic and functional outcomes have been reported to be satisfactory.

  1. "The Practical Perforator Flap": the sural artery flap for lower extremity soft tissue reconstruction in wounds of war

    NARCIS (Netherlands)

    O.J.F. van Waes (Oscar); J.A. Halm (Jens); J. Vermeulen (Jefrey); S. Ashford (Sofie)

    2012-01-01

    textabstractBackground: Sural artery perforator flaps have been described for use as both local flaps and in free tissue transfer. We present the use of this flap for compound soft tissue defects of the lower limb in civilian casualties of armed conflict in Afghanistan. Methods/results: Detailed

  2. The adverse effect of selective cyclooxygenase-2 inhibitor on random skin flap survival in rats.

    Directory of Open Access Journals (Sweden)

    Haiyong Ren

    Full Text Available BACKGROUND: Cyclooxygenase-2(COX-2 inhibitors provide desired analgesic effects after injury or surgery, but evidences suggested they also attenuate wound healing. The study is to investigate the effect of COX-2 inhibitor on random skin flap survival. METHODS: The McFarlane flap model was established in 40 rats and evaluated within two groups, each group gave the same volume of Parecoxib and saline injection for 7 days. The necrotic area of the flap was measured, the specimens of the flap were stained with haematoxylin-eosin(HE for histologic analysis. Immunohistochemical staining was performed to analyse the level of VEGF and COX-2 . RESULTS: 7 days after operation, the flap necrotic area ratio in study group (66.65 ± 2.81% was significantly enlarged than that of the control group(48.81 ± 2.33%(P <0.01. Histological analysis demonstrated angiogenesis with mean vessel density per mm(2 being lower in study group (15.4 ± 4.4 than in control group (27.2 ± 4.1 (P <0.05. To evaluate the expression of COX-2 and VEGF protein in the intermediate area II in the two groups by immunohistochemistry test .The expression of COX-2 in study group was (1022.45 ± 153.1, and in control group was (2638.05 ± 132.2 (P <0.01. The expression of VEGF in the study and control groups were (2779.45 ± 472.0 vs (4938.05 ± 123.6(P <0.01.In the COX-2 inhibitor group, the expressions of COX-2 and VEGF protein were remarkably down-regulated as compared with the control group. CONCLUSION: Selective COX-2 inhibitor had adverse effect on random skin flap survival. Suppression of neovascularization induced by low level of VEGF was supposed to be the biological mechanism.

  3. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME THREE: MARKET & TEAM

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  4. Release of hand burn contracture: comparing the ALT perforator flap with the gracilis free flap with split skin graft.

    Science.gov (United States)

    Misani, M; Zirak, C; Hau, Lê Thua Trung; De Mey, A; Boeckx, W

    2013-08-01

    The use of microsurgery in the management of burn sequelae is not a new idea. According to the properties of various types of free flaps different goals can be achieved or various additional procedures have to be combined. We report the comparison of two different free flaps on a single patient for reconstruction of both upper extremities for burn sequelae. A 1-year-old child sustained severe burns on both hands, arms and thorax and was initially only treated conservatively. This resulted in severe contractures. At the age of 4-years a free gracilis flap was selected for reconstruction of his left hand and a free anterolateral thigh flap for the right hand. We noticed a better functional and esthetic result for the gracilis flap associated with a shorter operative time and a minor donor site morbidity. The intraoperative technique and time, postoperative complications, functional and esthetic results and donor site morbidities were studied in the two types of flaps chosen. A review of literature was also performed. Our experience reported a better success of the gracilis muscle flap covered with a split skin graft compared to the anterolateral thigh flap in the reconstruction of hand function after severe burn sequelae. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  5. Dorsal hand coverage with free serratus fascia flap

    DEFF Research Database (Denmark)

    Fotopoulos, Peter; Holmer, Per; Leicht, Pernille

    2003-01-01

    in the flap, leaving the long thoracic nerve intact on the serratus muscle. Coverage of the flap with split-thickness skin graft is done immediately. The free serratus fascia flap is an ideal flap for dorsal hand coverage when the extensor tendons are exposed, especially because of low donor-site morbidity....

  6. Transanal pull-through procedure for Hirschsprung's disease: a 5-year experience.

    Science.gov (United States)

    Jester, I; Holland-Cunz, S; Loff, S; Hosie, S; Reinshagen, K; Wirth, H; Ali, M; Waag, K-L

    2009-04-01

    Transanal endorectal pull-through (TEPT) has become a widely used approach for the treatment of Hirschsprung's Disease. The technique is safe and, according to previous reports, it has a good clinical outcome. In this study our experience with TEPT in the early postoperative period is evaluated. The clinical course of 34 children (28 boys and 6 girls) who underwent one-stage pull-through operation according to De la Torre for Hirschsprung's disease from January 2003 to December 2007 was reviewed. Their ages ranged from 2 months to 4 years. Complications occurring within the first four weeks after operation were analyzed. Eight of 34 children (24 %) had early complications in the form of dehiscences of the anastomosis. Two children (6 %) had symptomatic anastomotic dehiscences. One child had an almost full retraction of the colon that had to be pulled down and resutured. One child developed a retrorectal abscess three weeks postoperatively due to anastomotic leakage. The dehiscences of 6 children (18 %) were asymptomatic. These dehiscences were detected only with standardized routine examination. The dehiscences healed uneventfully after resuturing. Two other patients (6 %) developed an anastomotic stricture that could be treated with rectal dilatations. Four children (12 %) showed a single episode of postoperative enterocolitis. The rate of early clinical and particularly subclinical complications such as anastomotic dehiscences after TEPT is higher than previously estimated. Patients should be monitored carefully during the early postoperative period. Severe complications can only be avoided with a thorough examination. Early resuturing of dehiscences might be helpful to prevent hazardous sequelae.

  7. Impact of pulling down regulatory state barriers on uranium in Australia: Is there a need in order to maintain and increase Australia’s global market share of uranium?

    Directory of Open Access Journals (Sweden)

    Ikhlaas Gurrib

    2013-10-01

    Full Text Available This paper sets a prospective framework to study the impact of opening more mines to meet future growing demand on Australia’s economy. The structure is aimed at decomposing investments and exports variables into Uranium exports and Uranium Exploration expenditure and analyse their impacts on each State GSP (Goods State Product and for Australia as a nation. The demand and supply factors affecting the uranium market are defragmented before providing the research methodology and data specifics. Later analysis is expected to have policy implications by serving as a guide to pull down State Regulatory barriers like those imposed currently in Queensland, which is rich with uranium deposits and allow only uranium exploration but no uranium mining. Empirical findings would suggest whether exporting the carbon free energy would add value to Australia’s different competing states and as a whole globalized economy.

  8. Dermatosurgery Rounds - The Island SKIN Infraorbital Flap

    Directory of Open Access Journals (Sweden)

    Georgi Tchernev

    2017-07-01

    Full Text Available The main objective in dermatologic surgery is complete excision of the tumour while achieving the best possible functional and cosmetic outcome. Also we must take into account age, sex, and tumour size and site. We should also consider the patient's expectations, the preservation of the different cosmetic units, and the final cosmetic outcome. Various reconstructive methods ranging from secondary healing to free flap applications are usedfor the reconstruction of perinasal or facial defects caused by trauma or tumour surgery. Herein, we describe the nasal infraorbital island skin flap for the reconstruction in a patient with basal cell carcinoma. No complications were observed in operation field. The infraorbital island skin flap which we describe for the perinasal area reconstruction is a safe, easily performed and versatile flap. The multidimensional use of this flap together with a relatively easy reconstruction plan and surgical procedure would be effective in flap choice.

  9. Elbow Reconstruction Using Island Flap for Burn Patients

    Directory of Open Access Journals (Sweden)

    Gi Yeun Hur

    2012-11-01

    Full Text Available Background Deep burns of the elbow lead to soft tissue necrosis and infection, with exposureof deep structures. Adequate wound coverage of this area requires thin, pliable, and durabletissue, while optimal functional recovery requires early coverage and functional rehabilitation.We have found 3 types of island flaps that provide reliable coverage for the elbow.Methods A retrospective study was performed on all patients who underwent flap coverageof an elbow defect at our hospital. The patients’ data including age, sex, cause of injury, wounddimensions, timing of flap coverage, postoperative elbow motion, and complications wereinvestigated.Results Between 2001 and 2012, 16 patients were treated at our hospital. The mean agewas 53.3 years. Three kinds of flaps were performed: 9 latissimus dorsi flaps, 4 lateral armflaps, and 4 radial forearm flaps. The average defect size was 183.5 cm2 (range, 28 to 670cm2. Wound coverage was performed at mean duration of 45.9 days (range, 14 to 91 days.The mean postoperative active elbow flexion was 98° (range, 85° to 115°. Partial flap failureoccurred in 1 latissimus dorsi flap. Minor complications included partial flap loss (11.8%,hematoma (23.5%, seroma (35.3%, and wound infection (5.9%.Conclusions Flap selection for elbow reconstruction is determined by the defect size andthe extent of the adjacent tissue injury. Elbow reconstruction using an island flap is a singlestaged,reliable, and relatively simple procedure that permits initiation of early rehabilitation,thereby improving a patient’s functional outcome.

  10. Single crystal fibers growth of double lithium, lanthanium molybdate and adjustment of a micro-pulling down furnace for high vacuum setup; Crescimento de fibras de molibdato duplo de litio e lantanio e adaptacao de sistema de alto vacuo para micro pulling-down

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Fernando Rodrigues da

    2013-07-01

    In this work we investigated crystal growth procedures aiming the development of single crystal fiber (SCF) for laser applications. For quality optimization in the fabrication of fluorides SCF a new growth chamber for a micro-pulling down furnace ({mu}-PD) was constructed targeting the fibers fabrication with strict atmosphere control (high vacuum, gas flux and static atmospheres). Simultaneously, the SCF growth process of rare earth double molybdates was studied. The growth of pure and Nd{sup 3+}-doped SCF of LiLa(MoO{sub 4}){sub 2} (LLM) was studied in the range of 0,5 - 10mol% doping. The designed furnace growth chamber with controlled atmosphere was successfully constructed and tested under different conditions. Specially, it was tested with the growth of LiF SFC under CF{sub 4} atmosphere showing the expected results. Transparent and homogeneous SCF of Nd:LLM were grown. In the pure fibers was observed facets formation, however, these defects were minimized after tuning of the growth parameters and additionally with the fibers doping. X-ray analysis showed the crystallization of a single phase (space group I4{sub 1}/a); the optical coherence tomography showed the presence of scattering centers only in regions were some growth stability occurred due to the manual process control. The measured Nd{sup 3+} distribution showed uniform incorporation, indicative of a segregation coefficient close to unity in LLM. The potential laser gain of the system was determined using a numerical solution of the rate equations system for the 805nm, CW pumping regime, showing the maximum laser emission gain at 1.064 {mu}m for a Nd{sup 3+}-doping of 5mol%. (author)

  11. Prospective evaluation of outcome measures in free-flap surgery.

    LENUS (Irish Health Repository)

    Kelly, John L

    2004-08-01

    Free-flap failure is usually caused by venous or arterial thrombosis. In many cases, lack of experience and surgical delay also contribute to flap loss. The authors prospectively analyzed the outcome of 57 free flaps over a 28-month period (January, 1999 to April, 2001). The setting was a university hospital tertiary referral center. Anastomotic technique, ischemia time, choice of anticoagulant, and the grade of surgeon were recorded. The type of flap, medications, and co-morbidities, including preoperative radiotherapy, were also documented. Ten flaps were re-explored (17 percent). There were four cases of complete flap failure (6.7 percent) and five cases of partial failure (8.5 percent). In patients who received perioperative systemic heparin or dextran, there was no evidence of flap failure (p = .08). The mean ischemia time was similar in flaps that failed (95 +\\/- 29 min) and in those that survived (92 +\\/- 34 min). Also, the number of anastomoses performed by trainees in flaps that failed (22 percent), was similar to the number in flaps that survived (28 percent). Nine patients received preoperative radiotherapy, and there was complete flap survival in each case. This study reveals that closely supervised anastomoses performed by trainees may have a similar outcome to those performed by more senior surgeons. There was no adverse effect from radiotherapy or increased ischemia time on flap survival.

  12. Efficient flapping flight of pterosaurs

    Science.gov (United States)

    Strang, Karl Axel

    In the late eighteenth century, humans discovered the first pterosaur fossil remains and have been fascinated by their existence ever since. Pterosaurs exploited their membrane wings in a sophisticated manner for flight control and propulsion, and were likely the most efficient and effective flyers ever to inhabit our planet. The flapping gait is a complex combination of motions that sustains and propels an animal in the air. Because pterosaurs were so large with wingspans up to eleven meters, if they could have sustained flapping flight, they would have had to achieve high propulsive efficiencies. Identifying the wing motions that contribute the most to propulsive efficiency is key to understanding pterosaur flight, and therefore to shedding light on flapping flight in general and the design of efficient ornithopters. This study is based on published results for a very well-preserved specimen of Coloborhynchus robustus, for which the joints are well-known and thoroughly described in the literature. Simplifying assumptions are made to estimate the characteristics that can not be inferred directly from the fossil remains. For a given animal, maximizing efficiency is equivalent to minimizing power at a given thrust and speed. We therefore aim at finding the flapping gait, that is the joint motions, that minimize the required flapping power. The power is computed from the aerodynamic forces created during a given wing motion. We develop an unsteady three-dimensional code based on the vortex-lattice method, which correlates well with published results for unsteady motions of rectangular wings. In the aerodynamic model, the rigid pterosaur wing is defined by the position of the bones. In the aeroelastic model, we add the flexibility of the bones and of the wing membrane. The nonlinear structural behavior of the membrane is reduced to a linear modal decomposition, assuming small deflections about the reference wing geometry. The reference wing geometry is computed for

  13. Cannula-Assisted Flap Elevation (CAFE): a novel technique for developing flaps during skin-sparing mastectomies.

    Science.gov (United States)

    Grant, Michael D

    2015-02-01

    One of the most challenging procedures in breast surgery is the skin-sparing mastectomy (SSM). Various techniques and incisions have evolved that characterize this procedure; however, what is common in all of them is the smaller the incision, the more difficult it is to develop the skin flaps. A procedure was developed that incorporates the use of liposuction cannulas (without suction) to create the skin flaps. The technique and results are described in this manuscript. From October of 2012 to April 2014, 289 mastectomies (171 patients) were performed using the CAFE procedure on women of all shapes and sizes. Postoperatively, no problems were experienced with flap viability using this technique. The main difference in side effects between the CAFE technique and other standard techniques for developing flaps in SSMs was more bruising than normal, but this resolved rapidly. The results for use of this technique were consistently impressive. The learning curve for this procedure is very short, especially for those who perform SSMs using sharp technique (scissors). Residents and fellows became proficient with the CAFE technique in a relatively short amount of time. Plastic surgeons were pleased with the cosmetic outcomes of their reconstructions that follow this type of mastectomy. Patients were extremely satisfied with their reconstructions as well. Incorporating the use of liposuction cannulas (without suction) makes the creation of flaps for SSM a relatively simple and rapid method. It is especially useful to assist in developing skin flaps with even the smallest of skin incisions.

  14. The prepuce free flap in 10 patients : modifications in flap design and surgical technique

    NARCIS (Netherlands)

    Werker, Paul M N

    The prepuce free flap was used in 10 oral and oropharyngeal reconstructions. During the course of this study, various modifications took place. Residual penile skin necrosis and skin island necrosis early in the series led to modification of flap design. This solved the donor-site problem by placing

  15. Emergency repair of upper extremity large soft tissue and vascular injuries with flow-through anterolateral thigh free flaps.

    Science.gov (United States)

    Zhan, Yi; Fu, Guo; Zhou, Xiang; He, Bo; Yan, Li-Wei; Zhu, Qing-Tang; Gu, Li-Qiang; Liu, Xiao-Lin; Qi, Jian

    2017-12-01

    Complex extremity trauma commonly involves both soft tissue and vascular injuries. Traditional two-stage surgical repair may delay rehabilitation and functional recovery, as well as increase the risk of infections. We report a single-stage reconstructive surgical method that repairs soft tissue defects and vascular injuries with flow-through free flaps to improve functional outcomes. Between March 2010 and December 2016 in our hospital, 5 patients with severe upper extremity trauma received single-stage reconstructive surgery, in which a flow-through anterolateral thigh free flap was applied to repair soft tissue defects and vascular injuries simultaneously. Cases of injured artery were reconstructed with the distal trunk of the descending branch of the lateral circumflex femoral artery. A segment of adjacent vein was used if there was a second artery injury. Patients were followed to evaluate their functional recoveries, and received computed tomography angiography examinations to assess peripheral circulation. Two patients had post-operative thumb necrosis; one required amputation, and the other was healed after debridement and abdominal pedicle flap repair. The other 3 patients had no major complications (infection, necrosis) to the recipient or donor sites after surgery. All the patients had achieved satisfactory functional recovery by the end of the follow-up period. Computed tomography angiography showed adequate circulation in the peripheral vessels. The success of these cases shows that one-step reconstructive surgery with flow-through anterolateral thigh free flaps can be a safe and effective treatment option for patients with complex upper extremity trauma with soft tissue defects and vascular injuries. Copyright © 2017. Published by Elsevier Ltd.

  16. Dual omental flap in obliterating post-pneumonectomy ...

    African Journals Online (AJOL)

    Background: Post-pneumonectomy bronchopleural fistulae is associated with high mortality and morbidity. The omental flap has been widely used to manage this condition either through laparoscopic or open surgery with varied degrees of success. We present a modification of the omental flap by using two flaps of the ...

  17. Vascularized Fibula Flaps for Mandibular Reconstruction: An ...

    African Journals Online (AJOL)

    For decades, osseous vascularised flaps have been used for reconstruction of the mandible with the vascularised fibula flap (VFF) remaining the commonly used osseous free flap, reasons ranging from its adequate bone and pedicle length to its receptive dental implant placement quality. This report considers a modest use ...

  18. Casing pull tests for directionally drilled environmental wells

    International Nuclear Information System (INIS)

    Staller, G.E.; Wemple, R.P.; Layne, R.R.

    1994-11-01

    A series of tests to evaluate several types of environmental well casings have been conducted by Sandia National Laboratories (SNL) and it's industrial partner, The Charles Machine Works, Inc. (CMW). A test bed was constructed at the CMW test range to model a typical shallow, horizontal, directionally drilled wellbore. Four different types of casings were pulled through this test bed. The loads required to pull the casings through the test bed and the condition of the casing material were documented during the pulling operations. An additional test was conducted to make a comparison of test bed vs actual wellbore casing pull loads. A directionally drilled well was emplaced by CMW to closely match the test bed. An instrumented casing was installed in the well and the pull loads recorded. The completed tests are reviewed and the results reported

  19. Casing pull tests for directionally drilled environmental wells

    Energy Technology Data Exchange (ETDEWEB)

    Staller, G.E.; Wemple, R.P. [Sandia National Labs., Albuquerque, NM (United States); Layne, R.R. [Charles Machine Works, Inc., Perry, OK (United States)

    1994-11-01

    A series of tests to evaluate several types of environmental well casings have been conducted by Sandia National Laboratories (SNL) and it`s industrial partner, The Charles Machine Works, Inc. (CMW). A test bed was constructed at the CMW test range to model a typical shallow, horizontal, directionally drilled wellbore. Four different types of casings were pulled through this test bed. The loads required to pull the casings through the test bed and the condition of the casing material were documented during the pulling operations. An additional test was conducted to make a comparison of test bed vs actual wellbore casing pull loads. A directionally drilled well was emplaced by CMW to closely match the test bed. An instrumented casing was installed in the well and the pull loads recorded. The completed tests are reviewed and the results reported.

  20. Reconstruction of pressure sores with perforator-based propeller flaps.

    Science.gov (United States)

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  1. Colgajo perforante tóracodorsal Toracodorsal perforator flap

    Directory of Open Access Journals (Sweden)

    C. Angrigiani

    2006-12-01

    Full Text Available La espalda es una excelente zona dadora de colgajos. El colgajo perforante tóracodorsal basado en ramas cutáneas de la arteria y vena tóracodorsales que perforan el músculo dorsal ancho, es una modifica ción del tradicional colgajo musculocutáneo de dorsal ancho que permite lograr una mayor flexibilidad en su traslado y una disminución de su volumen. Puede emplearse como colgajo libre o en isla. Presentamos su anatomía, disección e indicaciones.Back is an excellent donor site for flaps. The tora codorsal perforator flap, based on cutaneous vessels from toracodorsal artery and vein that pass through Latissimus Dorsi muscle, is a modified conventional musculocutaneous Latissimus Dorsi flap that allows easier movility and a volume reduction. This flap can be used both, free flap or island flap. We present the anatomy, dissection and applica tions of this flap.

  2. Posture-dependent aphasia: Focal cortical dysfunction in the sinking scalp flap syndrome

    Directory of Open Access Journals (Sweden)

    Prasad Krishnan

    2015-01-01

    Full Text Available Decompressive craniotomies are being increasingly used in the treatment of raised intracranial pressure due to a variety of reasons like large infarcts, hypertensive hemorrhages and contusions. Though effective in decreasing raised intracranial pressure, they have certain complications like the sinking scalp flap syndrome that is caused by cortical dysfunction of the area below the craniotomy which is exposed to the effects of atmospheric pressure. We describe a 60-year-old patient who underwent decompressive craniotomy for acute subdural hematoma and after an initial uneventful postoperative period developed incontinence, irrelevant verbalization and ataxia. He was found to have hydrocephalus and underwent a ventriculo-peritoneal shunt with resolution of his symptoms. Three weeks later his flap had sunk in deeply and the skin was non-pinchable and he was noted to have headaches, vomiting and retching when he sat up. In addition he became aphasic when seated and the symptoms subsided on lying down. A diagnosis of focal cortical dysfunction due to sinking scalp flap syndrome was made. We highlight the incidence and pathophysiology of this unusual complication of decompressive craniotomy and stress the need to be aware of this entity particularly in patients who do not show an initial improvement after decompressive craniotomy as the cause of their poor neurological status may not be explained by any other mechanism.

  3. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME ONE: PRELIMINARY DESIGN REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.; Chow, Ray [Zimitar, Inc.; Nordenholz, Thomas R. [The California Maritime Academy; Wamble, John Lee [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  4. Lift production through asymmetric flapping

    Science.gov (United States)

    Jalikop, Shreyas; Sreenivas, K. R.

    2009-11-01

    At present, there is a strong interest in developing Micro Air Vehicles (MAV) for applications like disaster management and aerial surveys. At these small length scales, the flight of insects and small birds suggests that unsteady aerodynamics of flapping wings can offer many advantages over fixed wing flight, such as hovering-flight, high maneuverability and high lift at large angles of attack. Various lift generating mechanims such as delayed stall, wake capture and wing rotation contribute towards our understanding of insect flight. We address the effect of asymmetric flapping of wings on lift production. By visualising the flow around a pair of rectangular wings flapping in a water tank and numerically computing the flow using a discrete vortex method, we demonstrate that net lift can be produced by introducing an asymmetry in the upstroke-to-downstroke velocity profile of the flapping wings. The competition between generation of upstroke and downstroke tip vortices appears to hold the key to understanding this lift generation mechanism.

  5. Versatality of Nasolabial Flap in Orofacial Reconstruction

    Directory of Open Access Journals (Sweden)

    Nandesh Shetty

    2015-01-01

    Materials and Methods: A total of 10 patients were selected based on the size of surgical defect. Nasolabial flap was used to reconstruct defects of small to moderate size in the oro-facial region and post-operative follow up was done. Results: All of the patients underwent inferiorly based Transposition Island flap for reconstruction of different oro-facial defects. Few complications like bulky size of the flap, slight donor site distortion (scar formation and intra-oral hair growth were seen in six patients. Two incidences of infection in the transferred flap were seen. Conclusion: It is a safe minor procedure done under general anesthesia with good reconstructive results over small or moderately sized maxillofacial defects. Proper attention to flap design, operative technique and post - operative management are useful in reducing the incidence of complications.

  6. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available BackgroundRobots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction.MethodsWe investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated.ResultsAmong five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes, and complications including flap necrosis, hematoma, and wound dehiscence did not occur.ConclusionsThis study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

  7. Flow field of flexible flapping wings

    Science.gov (United States)

    Sallstrom, Erik

    The agility and maneuverability of natural fliers would be desirable to incorporate into engineered micro air vehicles (MAVs). However, there is still much for engineers to learn about flapping flight in order to understand how such vehicles can be built for efficient flying. The goal of this study is to develop a methodology for capturing high quality flow field data around flexible flapping wings in a hover environment and to interpret it to gain a better understanding of how aerodynamic forces are generated. The flow field data was captured using particle image velocimetry (PIV) and required that measurements be taken around a repeatable flapping motion to obtain phase-averaged data that could be studied throughout the flapping cycle. Therefore, the study includes the development of flapping devices with a simple repeatable single degree of freedom flapping motion. The acquired flow field data has been examined qualitatively and quantitatively to investigate the mechanisms behind force production in hovering flight and to relate it to observations in previous research. Specifically, the flow fields have been investigated around a rigid wing and several carbon fiber reinforced flexible membrane wings. Throughout the whole study the wings were actuated with either a sinusoidal or a semi-linear flapping motion. The semi-linear flapping motion holds the commanded angular velocity nearly constant through half of each half-stroke while the sinusoidal motion is always either accelerating or decelerating. The flow fields were investigated by examining vorticity and vortex structures, using the Q criterion as the definition for the latter, in two and three dimensions. The measurements were combined with wing deflection measurements to demonstrate some of the key links in how the fluid-structure interactions generated aerodynamic forces. The flow fields were also used to calculate the forces generated by the flapping wings using momentum balance methods which yielded

  8. Laparoscopically assisted anorectal pull-through for rectovestibular ...

    African Journals Online (AJOL)

    Laparoscopically assisted anorectal pull-through for rectovestibular fistula. Taha Alkhatrawi, Radi Elsherbini, Waheed Alturkistani. Abstract. Purpose Laparoscopically assisted anorectal pull-through (LAARP) has been described as an alternative to posterior sagittal anorectoplasty for the surgical treatment of rectourethral ...

  9. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction

    NARCIS (Netherlands)

    Hekner, D.D.; Roeling, TAP; van Cann, EM

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were

  10. Perforator plus flaps: Optimizing results while preserving function and esthesis

    Directory of Open Access Journals (Sweden)

    Mehrotra Sandeep

    2010-01-01

    Full Text Available Background: The tenuous blood supply of traditional flaps for wound cover combined with collateral damage by sacrifice of functional muscle, truncal vessels, or nerves has been the bane of reconstructive procedures. The concept of perforator plus flaps employs dual vascular supply to flaps. By safeguarding perforators along with supply from its base, robust flaps can be raised in diverse situations. This is achieved while limiting collateral damage and preserving nerves, vessels, and functioning muscle with better function and aesthesis. Materials and Methods: The perforator plus concept was applied in seven different clinical situations. Functional muscle and fasciocutaneous flaps were employed in five and adipofascial flaps in two cases, primarily involving lower extremity defects and back. Adipofascial perforator plus flaps were employed to provide cover for tibial fracture in one patients and chronic venous ulcer in another. Results: All flaps survived without any loss and provided long-term stable cover, both over soft tissue and bone. Functional preservation was achieved in all cases where muscle flaps were employed with no clinical evidence of loss of power. There was no sensory loss or significant oedema in or distal to the flap in both cases where neurovascular continuity was preserved during flap elevation. Fracture union and consolidation were satisfactory. One patient had minimal graft loss over fascia which required application of stored grafts with subsequent take. No patient required re-operation. Conclusions: Perforator plus concept is holistic and applicable to most flap types in varied situations. It permits the exercise of many locoregional flap options while limiting collateral functional damage. Aesthetic considerations are also addressed while raising adipofascial flaps because of no appreciable donor defects. With quick operating times and low failure risk, these flaps can be a better substitute to traditional flaps and at

  11. A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft.

    Science.gov (United States)

    Lim, Hyoseob; Han, Dae Hee; Lee, Il Jae; Park, Myong Chul

    2014-03-01

    Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.

  12. A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft

    Directory of Open Access Journals (Sweden)

    Hyoseob Lim

    2014-03-01

    Full Text Available Background Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. Methods We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Results Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. Conclusions A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.

  13. Repair of nostril stenosis using a triple flap combination: boomerang, nasolabial, and vestibular rotation flaps.

    Science.gov (United States)

    Bozkurt, Mehmet; Kapi, Emin; Kuvat, Samet Vasfi; Selçuk, Caferi Tayyar

    2012-11-01

    Tissue losses within the nose due to various reasons result in the loss of normal anatomy and function. The external nasal valve area is one of the most important functional components of the nose. The columella, lobule, nostril, and alar region are among the components forming the external nasal valve area. Deformities of the nostrils are among the most frequently observed features that interfere with the functional anatomy of the nose. Malformations of the nostrils often emerge subsequent to cleft lip repairs. Stenoses are a common type of pathology among nostril deformities. In cases where a stenosis has formed, breathing problems and developmental anomalies may occur. In the patient with nostril stenosis presented in this report, there was a serious alar collapse and contracture subsequent to a cleft lip repair. In order to repair the nostril stenosis, a "boomerang flap" was chosen. This boomerang flap was used in combination with a nasolabial flap, a vestibular rotation flap, and a conchal cartilage graft to achieve a satisfactory repair.

  14. Positioning the 5'-flap junction in the active site controls the rate of flap endonuclease-1-catalyzed DNA cleavage

    KAUST Repository

    Song, Bo

    2018-02-09

    Flap endonucleases catalyze cleavage of single-stranded DNA flaps formed during replication, repair and recombination, and are therefore essential for genome processing and stability. Recent crystal structures of DNA-bound human flap endonuclease (hFEN1) offer new insights into how conformational changes in the DNA and hFEN1 may facilitate the reaction mechanism. For example, previous biochemical studies of DNA conformation performed under non-catalytic conditions with Ca2+ have suggested that base unpairing at the 5\\'-flap:template junction is an important step in the reaction, but the new structural data suggest otherwise. To clarify the role of DNA changes in the kinetic mechanism, we measured a series of transient steps - from substrate binding to product release - during the hFEN1-catalyzed reaction in the presence of Mg2+. We found that while hFEN1 binds and bends DNA at a fast, diffusion-limited rate, much slower Mg2+-dependent conformational changes in DNA around the active site are subsequently necessary and rate-limiting for 5\\'-flap cleavage. These changes are reported overall by fluorescence of 2-aminopurine at the 5\\'-flap:template junction, indicating that local DNA distortion (e.g., disruption of base stacking observed in structures), associated with positioning the 5\\'-flap scissile phosphodiester bond in the hFEN1 active site, controls catalysis. hFEN1 residues with distinct roles in the catalytic mechanism, including those binding metal ions (Asp-34, Asp-181), steering the 5\\'-flap through the active site and binding the scissile phosphate (Lys-93, Arg-100), and stacking against the base 5\\' to the scissile phosphate (Tyr-40), all contribute to these rate-limiting conformational changes, ensuring efficient and specific cleavage of 5\\'-flaps.

  15. Positioning the 5'-flap junction in the active site controls the rate of flap endonuclease-1-catalyzed DNA cleavage

    KAUST Repository

    Song, Bo; Hamdan, Samir; Hingorani, Manju M

    2018-01-01

    Flap endonucleases catalyze cleavage of single-stranded DNA flaps formed during replication, repair and recombination, and are therefore essential for genome processing and stability. Recent crystal structures of DNA-bound human flap endonuclease (hFEN1) offer new insights into how conformational changes in the DNA and hFEN1 may facilitate the reaction mechanism. For example, previous biochemical studies of DNA conformation performed under non-catalytic conditions with Ca2+ have suggested that base unpairing at the 5'-flap:template junction is an important step in the reaction, but the new structural data suggest otherwise. To clarify the role of DNA changes in the kinetic mechanism, we measured a series of transient steps - from substrate binding to product release - during the hFEN1-catalyzed reaction in the presence of Mg2+. We found that while hFEN1 binds and bends DNA at a fast, diffusion-limited rate, much slower Mg2+-dependent conformational changes in DNA around the active site are subsequently necessary and rate-limiting for 5'-flap cleavage. These changes are reported overall by fluorescence of 2-aminopurine at the 5'-flap:template junction, indicating that local DNA distortion (e.g., disruption of base stacking observed in structures), associated with positioning the 5'-flap scissile phosphodiester bond in the hFEN1 active site, controls catalysis. hFEN1 residues with distinct roles in the catalytic mechanism, including those binding metal ions (Asp-34, Asp-181), steering the 5'-flap through the active site and binding the scissile phosphate (Lys-93, Arg-100), and stacking against the base 5' to the scissile phosphate (Tyr-40), all contribute to these rate-limiting conformational changes, ensuring efficient and specific cleavage of 5'-flaps.

  16. Triple flap technique for vulvar reconstruction.

    Science.gov (United States)

    Mercut, R; Sinna, R; Vaucher, R; Giroux, P A; Assaf, N; Lari, A; Dast, S

    2018-04-09

    Perineal defects are encountered ever more frequently, in the treatment of vulvar cancers or abdominoperineal resection. The surgical treatment of vulvar cancer leads to significant skin defect. The aim of the reconstruction is not to provide volume but rather to resurface perineum. We propose a new solution to cover the extensive skin defect remaining after excision. We report 3 patients who underwent large excision for vulvar cancer, with lymph node dissection. For reconstruction, we performed 3 advancement flaps. Two V-Y flaps cantered on the infra-gluteal folds and based on pudendal perforator arteries were used to cover the postero-lateral parts of the defect. The third advancement flap from the superior aspect of the defect was a Y-V Mons pubis flap. The defects were successfully covered by the 3 flap technique. The first patient suffered a non-union that slowly healed by secondary intention. For the other cases, we used the same technique, but applied negative pressure wound therapy on the sutures, with excellent results. The 3 flap technique is a simple and reliable method and the donor site morbidity is minimal. It can be realised without changing the position of the patient after tumour excision, and does not require delicate perforator dissection. This surgical option can be easily applied, allowing better management of these cases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  17. "Internet of Things" Real-Time Free Flap Monitoring.

    Science.gov (United States)

    Kim, Sang Hun; Shin, Ho Seong; Lee, Sang Hwan

    2018-01-01

    Free flaps are a common treatment option for head and neck reconstruction in plastic reconstructive surgery, and monitoring of the free flap is the most important factor for flap survival. In this study, the authors performed real-time free flap monitoring based on an implanted Doppler system and "internet of things" (IoT)/wireless Wi-Fi, which is a convenient, accurate, and efficient approach for surgeons to monitor a free flap. Implanted Doppler signals were checked continuously until the patient was discharged by the surgeon and residents using their own cellular phone or personal computer. If the surgeon decided that a revision procedure or exploration was required, the authors checked the consumed time (positive signal-to-operating room time) from the first notification when the flap's status was questioned to the determination for revision surgery according to a chart review. To compare the efficacy of real-time monitoring, the authors paired the same number of free flaps performed by the same surgeon and monitored the flaps using conventional methods such as a physical examination. The total survival rate was greater in the real-time monitoring group (94.7% versus 89.5%). The average time for the real-time monitoring group was shorter than that for the conventional group (65 minutes versus 86 minutes). Based on this study, real-time free flap monitoring using IoT technology is a method that surgeon and reconstruction team can monitor simultaneously at any time in any situation.

  18. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. EXTENDED REVERSE SURAL FLAP FOR LOWER LIMB COVERAGE

    Directory of Open Access Journals (Sweden)

    Biswajit Mishra

    2018-12-01

    Full Text Available BACKGROUND The reverse sural artery flap has been a workhorse for the reconstruction of distal third of leg, ankle, sole and foot. Major limitation of reverse sural flap has been venous congestion particularly when harvested from proximal third of the leg. Objective- To evaluate the efficacy, safety of the extended reverse sural flap from proximal third of the leg. MATERIALS AND METHODS A prospective study was conducted at the department of plastic surgery on twenty patients who needed soft tissue reconstruction in the distal third of the leg, ankle, heel, forefoot and midfoot due to various cause. In all cases flap was extended proximally to the upper third of the calf and neurovenoadipo fascial pedicled sural fasciocutaneous flap was harvested. RESULTS There were only two cases of marginal necrosis. None of the patients had complete necrosis. Two patients developed hypertrophy of the flap margin. CONCLUSION Distally based neuroveno adipofascial pedicled sural fasciocutaneous flap can be safely extended to proximal third of the leg and is a reliable option for reconstruction of the defects in the foot, ankle and sole.

  20. Flap Edge Noise Reduction Fins

    Science.gov (United States)

    Khorrami, Mehdi R. (Inventor); Choudhan, Meelan M. (Inventor)

    2015-01-01

    A flap of the type that is movably connected to an aircraft wing to provide control of an aircraft in flight includes opposite ends, wherein at least a first opposite end includes a plurality of substantially rigid, laterally extending protrusions that are spaced apart to form a plurality of fluidly interconnected passageways. The passageways have openings adjacent to upper and lower sides of the flap, and the passageways include a plurality of bends such that high pressure fluid flows from a high pressure region to a low pressure region to provide a boundary condition that inhibits noise resulting from airflow around the end of the flap.

  1. Phosphate steering by Flap Endonuclease 1 promotes 5′-flap specificity and incision to prevent genome instability

    KAUST Repository

    Tsutakawa, Susan E.

    2017-06-27

    DNA replication and repair enzyme Flap Endonuclease 1 (FEN1) is vital for genome integrity, and FEN1 mutations arise in multiple cancers. FEN1 precisely cleaves single-stranded (ss) 5\\'-flaps one nucleotide into duplex (ds) DNA. Yet, how FEN1 selects for but does not incise the ss 5\\'-flap was enigmatic. Here we combine crystallographic, biochemical and genetic analyses to show that two dsDNA binding sites set the 5\\'polarity and to reveal unexpected control of the DNA phosphodiester backbone by electrostatic interactions. Via phosphate steering\\', basic residues energetically steer an inverted ss 5\\'-flap through a gateway over FEN1\\'s active site and shift dsDNA for catalysis. Mutations of these residues cause an 18,000-fold reduction in catalytic rate in vitro and large-scale trinucleotide (GAA) repeat expansions in vivo, implying failed phosphate-steering promotes an unanticipated lagging-strand template-switch mechanism during replication. Thus, phosphate steering is an unappreciated FEN1 function that enforces 5\\'-flap specificity and catalysis, preventing genomic instability.

  2. Reconstructive Surgery for Severe Penile Inadequacy: Phalloplasty with a Free Radial Forearm Flap or a Pedicled Anterolateral Thigh Flap

    Directory of Open Access Journals (Sweden)

    N. Lumen

    2008-01-01

    Full Text Available Objectives. Severe penile inadequacy in adolescents is rare. Phallic reconstruction to treat this devastating condition is a major challenge to the reconstructive surgeon. Phallic reconstruction using the free radial forearm flap (RFF or the pedicled anterolateral thigh flap (ALTF has been routinely used in female-to-male transsexuals. Recently we started to use these techniques in the treatment of severe penile inadequacy. Methods. Eleven males (age 15 to 42 years were treated with a phallic reconstruction. The RFF is our method of choice; the ALTF is an alternative when a free flap is contraindicated or less desired by the patient. The RFF was used in 7 patients, the ALTF in 4 patients. Mean followup was 25 months (range: 4–49 months. Aesthetic and functional results were evaluated. Results. There were no complications related to the flap. Aesthetic results were judged as “good” in 9 patients and “moderate” in 2 patients. Sensitivity in the RFF was superior compared to the ALTF. Four patients developed urinary complications (stricture and/or fistula. Six patients underwent erectile implant surgery. In 2 patients the erectile implant had to be removed due to infection or erosion. Conclusion. In case of severe penile inadequacy due to whatever condition, a phalloplasty is the preferred treatment nowadays. The free radial forearm flap is still the method of choice. The anterolateral thigh flap can be a good alternative, especially when free flaps are contraindicated, but sensitivity is markedly inferior in these flaps.

  3. A Review Of Pectoralis Major Musculocutaneous Island Flap In ...

    African Journals Online (AJOL)

    Like microvascular free flaps, pectoralis major flaps can be transferred in a single stage and have largely replaced deltepectoral (Bakanjiam) flap in head and neck reconstruction. This retrospective study was carried out to highlight the usefulness of this flap in different situations. Ten patients, aged six to 55 years operated ...

  4. The effect of laterally positioned flap-revised technique and 24% ethylenediaminetetraacetic acid root conditioning on root coverage: A case report

    Directory of Open Access Journals (Sweden)

    Jagmohan Singh

    2014-07-01

    Full Text Available Complete root coverage is considered the true goal of treatment of gingival recession defects because only complete coverage assures recovery from the hypersensitivity and esthetic defects associated with recession areas. Previous studies have shown that the laterally positioned flap (LPF technique or root surface biomodification yields a higher percentage of complete root coverage upon gingival recession treatment. This article highlights the use of the laterally positioned pedicle flap-revised technique (LPFRT as a modification of the LPF technique, along with 24% EDTA gel as a root surface biomodification agent, in the management of localized gingival recession defects. Clinical examination revealed a Miller class II recession defect on the buccal aspect of the lower right central incisor, as well as the presence of aberrant frenum pull adjacent to the recession defect. The LPFRT, together with 24% EDTA gel, was speculated to cover the gingival recession defect. The frenectomy, along with periosteal fenestration, was planned simultaneously with LPFRT. After 6 months of therapy, the clinical condition was stable with complete root coverage and satisfactory healing of the gingival tissues at both the donor and recipient sites with no signs of inflammation.

  5. Aerodynamics, sensing and control of insect-scale flapping-wing flight

    Science.gov (United States)

    Shyy, Wei; Kang, Chang-kwon; Chirarattananon, Pakpong; Ravi, Sridhar; Liu, Hao

    2016-01-01

    There are nearly a million known species of flying insects and 13 000 species of flying warm-blooded vertebrates, including mammals, birds and bats. While in flight, their wings not only move forward relative to the air, they also flap up and down, plunge and sweep, so that both lift and thrust can be generated and balanced, accommodate uncertain surrounding environment, with superior flight stability and dynamics with highly varied speeds and missions. As the size of a flyer is reduced, the wing-to-body mass ratio tends to decrease as well. Furthermore, these flyers use integrated system consisting of wings to generate aerodynamic forces, muscles to move the wings, and sensing and control systems to guide and manoeuvre. In this article, recent advances in insect-scale flapping-wing aerodynamics, flexible wing structures, unsteady flight environment, sensing, stability and control are reviewed with perspective offered. In particular, the special features of the low Reynolds number flyers associated with small sizes, thin and light structures, slow flight with comparable wind gust speeds, bioinspired fabrication of wing structures, neuron-based sensing and adaptive control are highlighted. PMID:27118897

  6. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available Background  Robots have allowed head and neck surgeons to extirpate oropharyngealtumors safely without the need for lip-split incision or mandibulotomy. Using robots inoropharyngealreconstruction is newbut essentialfor oropharyngeal defectsthatresultfromrobotic tumor excision. We report our experience with robotic free-flap reconstruction ofhead and neck defectsto exemplify the necessity forrobotic reconstruction.Methods  We investigated head and neck cancer patients who underwent ablation surgeryand free-flap reconstruction by robot. Between July 1, 2011 andMarch 31, 2012, 5 caseswereperformed and patient demographics, location of tumor, pathologic stage, reconstructionmethods, flap size, recipient vessel, necessary pedicle length, and operation time wereinvestigated.Results  Among five free-flap reconstructions, four were radial forearm free flaps and onewas an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and oneflap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flapinsetting and microanastomosis were achieved using a specially manufactured roboticinstrument. The total operation timewas 1,041.0 minutes(range, 814 to 1,132 minutes, andcomplicationsincluding flap necrosis, hematoma, andwound dehiscence did not occur.Conclusions  Thisstudy demonstratesthe clinically applicable use ofrobotsin oropharyngealreconstruction, especially using a free flap. A robot can assist the operator in insettingthe flap at a deep portion of the oropharynx without the need to perform a traditionalmandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methodsand is accepted asthemost up-to-datemethod.

  7. Analytical Model for Hook Anchor Pull-Out

    DEFF Research Database (Denmark)

    Brincker, Rune; Ulfkjær, Jens Peder; Adamsen, Peter

    1995-01-01

    A simple analytical model for the pull-out of a hook anchor is presented. The model is based on a simplified version of the fictitious crack model. It is assumed that the fracture process is the pull-off of a cone shaped concrete part, simplifying the problem by assuming pure rigid body motions...... allowing elastic deformations only in a layer between the pull-out cone and the concrete base. The derived model is in good agreement with experimental results, it predicts size effects and the model parameters found by calibration of the model on experimental data are in good agreement with what should...

  8. Analytical Model for Hook Anchor Pull-out

    DEFF Research Database (Denmark)

    Brincker, Rune; Ulfkjær, J. P.; Adamsen, P.

    A simple analytical model for the pull-out of a hook anchor is presented. The model is based on a simplified version of the fictitious crack model. It is assumed that the fracture process is the pull-off of a cone shaped concrete part, simplifying the problem by assuming pure rigid body motions...... allowing elastic deformations only in a layer between the pull-out cone and the concrete base. The derived model is in good agreement with experimental results, it predicts size effects and the model parameters found by calibration of the model on experimental data are in good agreement with what should...

  9. Problem solving capabilities of Peach-fronted Conures (Eupsittula aurea) studied by the string-pulling test

    DEFF Research Database (Denmark)

    Ortiz, Sara Torres; Larsen, Ole Næsbye; Wahlberg, Magnus

    Many studies have indicated advanced cognitive abilities in different species of parrots and ravens. Here we investigated basic cognitive skills of Peach-fronted Conures (Eupsittula aurea) using the string-pulling test. These small Middle-American parrots are often compared to dolphins due...... not be obtained by flying or reached from the ground. By varying different spatial configurations of strings and rewards, different cognitive skills could be investigated. Four conures (two females and two males) were tested. All four individuals solved three out of four tested string configurations (four...... straight strings, two slant strings, two contact-no contact strings) within 14 seconds on average, but all failed in a crossed two-string test. Subsequently we tested the birds with a vertical pulley that required the birds to pull the string down to get the food reward within reach from below...

  10. Revisit of Nasolabial flap in the reconstruction of defects involving ...

    African Journals Online (AJOL)

    Conclusion: Data from this study suggest that NL flap is a reliable option for reconstruction of the oral floor, in form as well as function, without esthetic compromise and has a major role even in this era of free flaps. Keywords: Floor of mouth defects, local flaps, nasolabail flap, oral cavity defects, reconstruction, regional flaps ...

  11. Hair loss and hair-pulling in rhesus macaques (Macaca mulatta).

    Science.gov (United States)

    Lutz, Corrine K; Coleman, Kristine; Worlein, Julie; Novak, Melinda A

    2013-07-01

    Alopecia is a common problem in rhesus macaque colonies. A possible cause of this condition is hair-pulling; however the true relationship between hair-pulling and alopecia is unknown. The purpose of this study was to examine the relationship between hair loss and hair-pulling in 1258 rhesus macaques housed in 4 primate colonies across the United States. Alopecia levels ranged from 34.3% to 86.5% (mean, 49.3%) at the primate facilities. At facilities reporting a sex-associated difference, more female macaques were reported to exhibit alopecia than were males. In contrast, more males were reported to hair-pull. Animals reported to hair-pull were significantly more likely to have some amount of alopecia, but rates of hair-pulling were substantially lower than rates of alopecia, ranging from 0.6% to 20.5% (mean, 7.7%) of the populations. These results further demonstrate that hair-pulling plays only a small role in alopecia in rhesus macaques.

  12. Temporalis myo-osseous flap: an experimental study

    International Nuclear Information System (INIS)

    Antonyshyn, O.; Colcleugh, R.G.; Hurst, L.N.; Anderson, C.

    1986-01-01

    The present paper investigates the anatomy and vascularization of the temporalis myo-osseous flap. This is a calvarial bone flap that employs temporalis muscle and its distal pericranial extension as a pedicle. In six human cadavers the flap was raised as an island on the anterior deep temporal artery after transecting the zygomatic arch and coronoid process. Maximal mobilization was thus obtained, allowing rotation of the flap into the mouth for intraoral reconstruction. The arc of rotation and potential surgical applications were noted. A comparative study of the temporalis myo-osseous flap and free calvarial bone graft was then conducted in a rabbit model. Vascularization of the calvarial bone flap was confirmed by technetium scintigraphy performed on the first postoperative day. The uptake of fluorochrome labels immediately after transfer verified the adequacy of the periosteal circulation in maintaining viability and new osteoid formation throughout the full thickness of calvarial bone. The transplantation of free calvarial bone grafts was followed by necrosis of most cellular elements. This was demonstrated by an absence of fluorochrome uptake up to 19 days postoperatively and a predominance of empty lacunae and nonviable marrow

  13. Adipofascial Anterolateral Thigh Flap Safety: Applications and Complications

    Directory of Open Access Journals (Sweden)

    Tommaso Agostini

    2013-03-01

    Full Text Available BackgroundA thinned anterolateral thigh (ALT flap is often harvested to achieve optimal skin resurfacing. Several techniques have been described to thin an ALT flap including an adipocutaneous flap, an adipofascial flap and delayed debulking.MethodsBy systematically reviewing all of the available literature in English and French, the present manuscript attempts to identify the common surgical indications, complications and donor site morbidity of the adipofascial variant of the ALT flap. The studies were identified by performing a systematic search on Medline, Ovid, EMBASE, the Cochrane Database of Systematic Reviews, Current Contents, PubMed, Google, and Google Scholar.ResultsThe study selection process was adapted from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, and 15 articles were identified using the study inclusion criteria. These articles were then reviewed for author name(s, year of publication, flap dimensions and thickness following defatting, perforator type, type of transfer, complications, thinning technique, number of cases with a particular area of application and donor site morbidity.ConclusionsThe adipofascial variant of the ALT flap provides tissue to fill large defects and improve pliability. Its strong and safe blood supply permits adequate immediate or delayed debulking without vascular complications. The presence of the deep fascia makes it possible to prevent sagging by suspending and fixing the flap for functional reconstructive purposes (e.g., the intraoral cavity. Donor site morbidity is minimal, and thigh deformities can be reduced through immediate direct closure or liposuction and direct closure. A safe blood supply was confirmed by the rate of secondary flap debulking.

  14. Reconstruction of eyelids with Washio flap in anophthalmia.

    Science.gov (United States)

    Tvrdek, M; Kozák, J

    2014-01-01

    The authors present a case report of a patient with anophthalmia in whom retroauriculo-temporal flap (Washio flap) was used for reconstruction of eyelids. This flap, which is mostly used for reconstructions of nasal defects, was not used in this way according to available literature.

  15. 急诊手外科中腹部任意型皮瓣的应用%Application of Abdominal Randomy Skin flap in the Acute Operation for hand

    Institute of Scientific and Technical Information of China (English)

    杨建勋; 王宁

    2002-01-01

    Objective To present the means and effect of repairing hand soft tissue defect. Methods To transplate from 45 patients'randomy skin flap to hand defect area, and cut off the peduncle. Result The survival of skin flap is satisfactory with softness and colorfamiliar to normal skin 1 ~ 3 years after operation. Conclusion Therapy is simple reliable and effective.

  16. Reconstruction of cica-contracture on the face and neck with skin flap and expanded skin flap pedicled by anterior branch of transverse cervical artery.

    Science.gov (United States)

    Chen, Baoguo; Song, Huifeng; Xu, Minghuo; Gao, Quanwen

    2016-09-01

    A high-quality flap is necessary for repairing faciocervical scar contractures. The supraclavicular region and chest wall are the preferred choices for reconstruction. The supraclavicular island flap (SIF) pedicled by the transverse cervical artery (TCA) has been reported. Compared to the traditional SIF flap, another type of flap pedicled by the anterior perforator of transverse cervical artery (ap-TCA) is more convenient for transfer to the faciocervical area. In this article, we use this type of perforator flap and expanded perforator flap to repair the faciocervical contracture. In this study, 10 cases (deformity caused by burn or trauma to the face and neck sites) with an average age of 32 years-old, were treated by ap-TCA flap and this type of expanded flap. In between, the flap was pre-expanded for approximately 3 months prior to transfer in 6 patients. Another 4 cases did not want the expander because of the long duration required for saline filling and potential complications of the expander. Bilateral prefabricated flaps were designed in two female cases. All 12 flaps in 10 patients were transferred tension-free to the defects and no flap was lost. The size of the flap ranged from 12 cm × 8 cm to 15 cm × 20 cm. All 12 flaps survived completely. The donor sites were closed directly in the above 6 patients where an expander had been used and reconstructed by split skin graft in 4 patients where no expander had been employed. Through a mean time of 6 months' follow-up, only one female patient was disappointed with the cicatrix that presented on the upper polar skin of both breasts, the other 9 patients were satisfied with both recipient function and appearance. The color and the texture matched well with the recipient area. The ap-TCA flap and expanded ap-TCA flap can be considered reliable options for faciocervical deformities as it can be easily elevated and it matches well with faciocervical area in color. With regards to the expanded flap, we

  17. Flexible wings in flapping flight

    Science.gov (United States)

    Moret, Lionel; Thiria, Benjamin; Zhang, Jun

    2007-11-01

    We study the effect of passive pitching and flexible deflection of wings on the forward flapping flight. The wings are flapped vertically in water and are allowed to move freely horizontally. The forward speed is chosen by the flapping wing itself by balance of drag and thrust. We show, that by allowing the wing to passively pitch or by adding a flexible extension at its trailing edge, the forward speed is significantly increased. Detailed measurements of wing deflection and passive pitching, together with flow visualization, are used to explain our observations. The advantage of having a wing with finite rigidity/flexibility is discussed as we compare the current results with our biological inspirations such as birds and fish.

  18. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME ZERO: OVERVIEW AND COMMERCIAL PATH

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  19. HIGH EFFICIENCY STRUCTURAL FLOWTHROUGH ROTOR WITH ACTIVE FLAP CONTROL: VOLUME TWO: INNOVATION & COST OF ENERGY

    Energy Technology Data Exchange (ETDEWEB)

    Zuteck, Michael D. [Zimitar, Inc.; Jackson, Kevin L. [Zimitar, Inc.; Santos, Richard A. [Zimitar, Inc.

    2015-05-16

    The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.

  20. Comparison of 5468 retreatments after laser in situ keratomileusis by lifting the flap or performing photorefractive keratectomy on the flap.

    Science.gov (United States)

    Ortega-Usobiaga, J; Llovet-Osuna, F; Katz, T; Djodeyre, M R; Druchkiv, V; Bilbao-Calabuig, R; Baviera, J

    2018-02-01

    To assess visual outcomes of retreatment after laser in situ keratomileusis (LASIK) by lifting the flap or performing photorefractive keratectomy (PRK) on the flap, as well as to establish whether there was an increased risk of epithelial ingrowth (EIG) when LASIK and lifting of the flap are separated by a long time interval and to determine the incidence of corneal haze after PRK. Retrospective study of 4077 patients (5468 eyes) who underwent LASIK and subsequent retreatment were reviewed in order to study their visual results and identify cases of EIG and corneal haze. Enhancements included 5196 eyes from 3876 patients that were retreated by lifting the flap, and 272 eyes from 201 patients that were retreated by PRK on the flap. No statistically significant differences were found between the retreatments in terms of predictability, efficacy, and safety. A total of 704 cases of EIG were found after lifting the flap, for which surgical cleansing was necessary in 70. Surgical cleansing decreased the efficacy index when compared with patients with EIG who did not need cleansing (P=.01). Differences in terms of safety and predictability were not statistically significant. The incidence of corneal haze after ablation of the surface of the previous flap was 14.34%, although none of these cases were clinically relevant. Visual outcomes were similar between patients who were retreated by lifting the flap and those who underwent PRK. The incidence of EIG when the flap was lifted was 13.55%. The incidence of EIG increases with the time elapsed between the primary procedure and retreatment. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Soft Palate Reconstruction Using Bilateral Palatal Mucomuscular Flap and Pharyngeal Flap after Resection of Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Jun Sik Kim

    2012-11-01

    Full Text Available Squamous cell carcinoma infrequently occurs at the soft palate. Although various methodscan be used for reconstruction of soft palate defects that occur after resecting squamous cellcarcinoma, it is difficult to obtain satisfactory results from the perspective of the functionalrestoration of the soft palate. A combination of bilateral palatal mucomuscular flap for theoral side and superiorly based posterior pharyngeal flap for the nasal side were performed ontwo patients who were diagnosed with squamous cell carcinoma of the soft palate in orderto reconstruct the soft palate defects after surgical resection. After surgery, the patients werefollowed-up for a mean period of 11 months. The flaps were well maintained in both patients.The donor site defects were epithelialized and completely recovered. Additionally, no recurrenceof the primary sites was shown. Slight hyponasality was observed in the voice assessmentsthat were conducted 6 months after surgery. No food regurgitation or aspiration was observedin the swallowing tests. We used a combination of bilateral palatal mucomuscular flap andsuperiorly based posterior pharyngeal flap to reconstruct the soft palate defects that occurredafter resecting the squamous cell carcinomas. We reduced the donor site complications andachieved functionally satisfactory outcomes.

  2. Defining the Role of Free Flaps in Partial Breast Reconstruction.

    Science.gov (United States)

    Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H

    2018-03-01

     Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer.  A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction.  There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap.  Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Medial canthal reconstruction with multiple local flaps

    Directory of Open Access Journals (Sweden)

    Akihiro Ogino

    2018-03-01

    Conclusion: This method is somewhat complicated compared to reconstruction with a single flap, but it is a combination of standard local flaps and is a simple reconstructive procedure. By adding additional resection, the suture line is consistent with the border of the facial unit, so postoperative scarring is inconspicuous. This technique is aesthetically useful because of the continuity of colour and texture resulting from the use of adjacent flaps.

  4. Young entrepreneurs pushed by necessity and pulled by opportunity

    DEFF Research Database (Denmark)

    Cheraghi, Maryam

    2017-01-01

    The vocational choice to be an entrepreneur is made in a social context of institutions in society, which channel, regulate, enable and constrain life, with pushes and pulls. The necessity to make a living may push the entrepreneur, or an opportunity for business may pull the entrepreneur to start....... The push by necessity and pull by opportunity are exerted by institutions in society such as its economy and culture. The purpose here is to account for how young entrepreneurs' experiences of opportunity-pull and necessity-push are influenced by society's economic wealth and culture, as traditional versus...... secular-rational culture and as survival versus self-expression culture. - A sample of 41,281 young entrepreneurs in 93 countries was surveyed in Global Entrepreneurship Monitor. - Analyses show that young entrepreneurs' experience of opportunity-pull rather than necessity-push is not distinctly...

  5. Clear Cell Adenocarcinoma Arising from Endometriosis in the Groin: Wide Resection and Reconstruction with a Fascia Lata Tensor Muscle Skin Flap

    Directory of Open Access Journals (Sweden)

    Shozo Yoshida

    2018-01-01

    Full Text Available We herein report a case of clear cell carcinoma arising from endometriosis in the groin in a 53-year-old woman. The findings of MRI and FDG/PET-CT indicated a malignant tumor, and surgical biopsy confirmed adenocarcinoma of the female genital tract. The tumor including a part of the abdominal rectus muscle and rectus sheath, subcutaneous fat, skin, and the right inguinal ligament was resected en bloc. The defect in the abdominal wall was reconstructed with a fascia lata tensor muscle skin flap. The tumor was composed of clear cell adenocarcinoma arising from extrapelvic endometriosis. The patient received chemotherapy with gemcitabine and carboplatin for 6 cycles and had no evidence of recurrence 7 months after the treatment. We herein described the diagnosis and surgical management of endometriosis-associated carcinoma in the groin.

  6. Accuracy of Visual Estimation of LASIK Flap Thickness.

    Science.gov (United States)

    Brenner, Jason E; Fadlallah, Ali; Hatch, Kathryn M; Choi, Catherine; Sayegh, Rony R; Kouyoumjian, Paul; Wu, Simon; Frangieh, George T; Melki, Samir A

    2017-11-01

    To assess the accuracy of surgeons' visual estimation of LASIK flap thickness when created by a femtosecond laser by comparing it to ultrasound measurements. Surgeons were asked to visually estimate the thickness of a femtosecond flap during the procedure. Total corneal thickness was measured by ultrasound pachymetry prior to the procedure and the stromal bed was similarly measured after flap lifting. The estimates from three experienced surgeons (cornea fellowship trained and more than 5 years in practice) were compared to those of three cornea fellows, with each surgeon evaluating 20 eyes (120 total). Surgeons were not told the thickness of the flaps unless required for safety reasons. The average difference between visual and ultrasonic estimation of LASIK flap thickness was 15.20 μm. The flap was 10 μm thicker than estimated in 37% of eyes, 20 μm thicker in 17% of eyes, and 30 μm thicker in 10% of eyes. The largest deviation was 53 μm. There was no statistically significant difference between the accuracy of experienced surgeons and fellows (P = .51). There are significant differences between surgeons' visual estimates and ultrasonic measurements of LASIK flap thickness. Relying on these visual estimates may lead to deeper excimer laser ablation than intended. This could lead to thinner residual stromal beds and higher percent tissue altered than planned. The authors recommend that surgeons measure flaps intraoperatively to maximize accuracy and safety. [J Refract Surg. 2017;33(11):765-767.]. Copyright 2017, SLACK Incorporated.

  7. Folding in and out: passive morphing in flapping wings.

    Science.gov (United States)

    Stowers, Amanda K; Lentink, David

    2015-03-25

    We present a new mechanism for passive wing morphing of flapping wings inspired by bat and bird wing morphology. The mechanism consists of an unactuated hand wing connected to the arm wing with a wrist joint. Flapping motion generates centrifugal accelerations in the hand wing, forcing it to unfold passively. Using a robotic model in hover, we made kinematic measurements of unfolding kinematics as functions of the non-dimensional wingspan fold ratio (2-2.5) and flapping frequency (5-17 Hz) using stereo high-speed cameras. We find that the wings unfold passively within one to two flaps and remain unfolded with only small amplitude oscillations. To better understand the passive dynamics, we constructed a computer model of the unfolding process based on rigid body dynamics, contact models, and aerodynamic correlations. This model predicts the measured passive unfolding within about one flap and shows that unfolding is driven by centrifugal acceleration induced by flapping. The simulations also predict that relative unfolding time only weakly depends on flapping frequency and can be reduced to less than half a wingbeat by increasing flapping amplitude. Subsequent dimensional analysis shows that the time required to unfold passively is of the same order of magnitude as the flapping period. This suggests that centrifugal acceleration can drive passive unfolding within approximately one wingbeat in small and large wings. Finally, we show experimentally that passive unfolding wings can withstand impact with a branch, by first folding and then unfolding passively. This mechanism enables flapping robots to squeeze through clutter without sophisticated control. Passive unfolding also provides a new avenue in morphing wing design that makes future flapping morphing wings possibly more energy efficient and light-weight. Simultaneously these results point to possible inertia driven, and therefore metabolically efficient, control strategies in bats and birds to morph or recover

  8. Pull-Through Capacity in Plywood and OSB

    DEFF Research Database (Denmark)

    Munch-Andersen, Jørgen; Sørensen, John Dalsgaard

    The characteristic pull-through capacity of heads of nails and screws is needed to determine the rope effect for laterally loaded fasteners used to fix sheathing to timberframes. There is no values given in EN 1995 (Eurocode 5) but data for the pull through capacity of nail and screw heads has be...

  9. Dynamic properties of blood flow and leukocyte mobilization in infected flaps

    International Nuclear Information System (INIS)

    Feng, L.J.; Price, D.C.; Mathes, S.J.; Hohn, D.

    1990-01-01

    Two aspects of the inflammatory response to infection--blood flow alteration and leukocyte mobilization--are investigated in the canine model. The elevation of paired musculocutaneous (MC) and random pattern (RP) flaps allowed comparison of healing flaps with significant differences in blood flow (lower in random pattern flaps) and resistance to infection (greater in musculocutaneous flaps). Blood flow changes as determined by radioactive xenon washout were compared in normal skin and distal flap skin both after elevation and following bacterial inoculation. Simultaneous use of In-111 labeled leukocytes allowed determination of leukocyte mobilization and subsequent localization in response to flap infection. Blood flow significantly improved in the musculocutaneous flap in response to infection. Although total leukocyte mobilization in the random pattern flap was greater, the leukocytes in the musculocutaneous flap were localized around the site of bacterial inoculation within the dermis. Differences in the dynamic blood flow and leukocyte mobilization may, in part, explain the greater reliability of musculocutaneous flaps when transposed in the presence of infection

  10. Análisis de controversias en reconstrucción mamaria con colgajo DIEP Analysis of debated uses in mammary reconstruction with DIEP flap

    Directory of Open Access Journals (Sweden)

    C. Casado Sánchez

    2008-12-01

    Full Text Available La reconstrucción mamaria mediante colgajo DIEP (Deep Inferior Epigastric Perforator se encuentra condicionada en muchas ocasiones por características de la paciente o del tratamiento oncológico recibido, de tal forma que diversos grupos de trabajo contraindican este método en caso de existir alguno de esos factores. Nosotros hemos realizado un estudio de los mismos, analizando su impacto sobre la viabilidad del colgajo y su correlación con las complicaciones postoperatorias, para optimizar así su indicación. Los condicionantes analizados son el tabaco, las intervenciones quirúrgicas previas que afecten en alguna medida la pared abdominal, el sobrepeso u obesidad de la paciente, el volumen de la mama contralateral, el tratamiento radioterápico anterior o posterior a la reconstrucción, y finalmente el gasto sanitario que supone. Estas controversias son a su vez las más discutidas en la literatura al respecto. Se valoran los resultados obtenidos tras 55 reconstrucciones mamarias mediante colgajo DIEP entre enero de 2000 y noviembre de 2005, así como los estudios y publicaciones más recientes existentes sobre esta materia. Hemos encontrado una pobre correlación entre los índices de fracaso del colgajo y las controversias estudiadas, determinando así dos contraindicaciones absolutas para que una paciente pudiese beneficiarse de un colgajo DIEP: abdominoplastia previa y radioterapia adyuvante tras reconstrucción inmediata. Los excelentes resultados que se obtienen globalmente, nos llevan a recomendar este colgajo por encima de otras opciones terapéuticas.The use of DIEP (Deep Inferior Epigastric Perforator flap surgery in breast reconstruction is often conditioned by the patient and the oncologic treatment characteristics to such an extent that several working groups advise against this surgical procedure when any of these factors is present. In the study of this interaction, an analysis of its impact on the flap feasibility and its

  11. Boomerang flap reconstruction for the breast.

    Science.gov (United States)

    Baumholtz, Michael A; Al-Shunnar, Buthainah M; Dabb, Richard W

    2002-07-01

    The boomerang-shaped latissimus dorsi musculocutaneous flap for breast reconstruction offers a stable platform for breast reconstruction. It allows for maximal aesthetic results with minimal complications. The authors describe a skin paddle to obtain a larger volume than either the traditional elliptical skin paddle or the extended latissimus flap. There are three specific advantages to the boomerang design: large volume, conical shape (often lacking in the traditional skin paddle), and an acceptable donor scar. Thirty-eight flaps were performed. No reconstruction interfered with patient's ongoing oncological regimen. The most common complication was seroma, which is consistent with other latissimus reconstructions.

  12. The effect of a slack-pulling device in reducing operator physiological workload during log winching operations.

    Science.gov (United States)

    Spinelli, Raffaele; Aalmo, Giovanna Ottaviani; Magagnotti, Natascia

    2015-01-01

    The authors conducted a comparative test to determine whether the introduction of a hydraulic slack puller allowed reducing the physiological workload of operators assigned to log winching tasks. The tests were conducted in northern Italy, on the mountains near Como. The study involved five volunteer subjects, considered representatives of the regional logging workforce. Physiological workload was determined by measuring the operators' heart rate upon completion of specific tasks. The slack puller improved the efficiency of downhill winching, since it allowed a single operator to pull out the cable on his own, without requiring the assistance of a colleague. However, introduction of the slack puller did not result in any reductions of operator physiological workload. The main stressor when working on a steep slope is moving up and down the slope: pulling a cable is only a secondary stressor. Any measures targeting secondary stressors are unlikely to produce dramatic reductions of operator workload.

  13. Tracer gas evaluations of push-pull ventilation system performance.

    Science.gov (United States)

    Ojima, Jun

    2009-01-01

    A push-pull ventilation system is effective for hazardous material exhaustion. Although a push-pull ventilation system has advantages over a local exhaust hood, some laborious adjustments are required. The pertinence of the adjustments is uncertain because it is difficult to evaluate the performance of a push-pull ventilation system quantitatively. In this study, a measurement of the capture efficiency of a push-pull ventilation system was carried out by means of a tracer gas method. The capture efficiency decreased to 39.3-78.5% when blockage material, a dummy worker and a cross draft, were set in the ventilation zone, but the efficiency was 95.1-97.9% when the cross draft was stopped. The results suggest that the uniform flow of a push-pull ventilation system will detour a blockage and the performance of the system will not be reduced unless a cross draft disturbs the uniform flow.

  14. Wavefront aberrometry and refractive outcomes of flap amputation after LASIK

    NARCIS (Netherlands)

    Al Saady, Rana L.; van der Meulen, Ivanka J.; Nieuwendaal, Carla P.; Engelbrecht, Leonore A.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    Laser in situ keratomileusis flap amputation was performed in 3 eyes of 2 patients because of flap melt and surface irregularity. In the first patient, a 34-year-old man, flaps were excised after a photorefractive keratectomy retreatment procedure on a previous LASIK flap had been done, secondary to

  15. Pulled elbow in infancy: diagnostic role of imaging

    International Nuclear Information System (INIS)

    Scapinelli, Raffaele; Borgo, Andrea

    2005-01-01

    Purpose. Pulled elbow is a common injury in infancy. Typically the child, after a sudden pull, refuses to use the arm. The history and clinical findings are sufficient to make the diagnosis, and radiography or ultrasonography are not necessary. When imaging procedures are performed, a few small signs are useful to confirm the diagnosis of pulled elbow. Materials and methods. The authors reviewed the radiographic and ultrasonographic signs reported to be suggestive of pulled elbow (increased radio-condylar distance, increased radio-coronoid distance, proximal radio-ulnar diastasis, deviation of the radio-condylar line) and attempted to confirm their presence in children affected by this trauma. Results. Increased radio-condylar and radio-coronoid distance were present in 8 of 8 cases: proximal radio-ulnar diastasis and deviation of the radio-condylar line were inconsistently present. Ultrasonography gave contradictory results. Conclusions. In typical cases of pulled elbow, radiography or ultrasonography are not necessary for diagnosis and treatment. imaging procedures are recommended only in the case of non typical history, in the presence of deformity or traumatic skin lesions and in children over six years of age. Increased radio-coronoid distance on the affected side is the most frequent and visible sign, which can confirm the diagnosis of pulled elbow. Increased radio-condylar distance is also present, but it is not easy to visualize. Proximal radio-ulnar diastasis and deviation of the radio-condylar line are inconstant. Ultrasonography is difficult to standardize [it

  16. Reconstruction of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma by vascular anastomosed free dorsalis pedis flaps' transplantation.

    Science.gov (United States)

    Bi, Xiaoping; Fan, Xianqun; Zhou, Huifang; Shi, Wodong; Xiao, Caiwen; Lin, Min; Li, Zhenkang

    2011-05-01

    Retinoblastoma is a common malignant intraocular tumor in childhood, and most patients require enucleation or exenteration even with irradiation. Severe anophthalmic orbits and atresic eye sockets are not rare. We conducted a retrospective study to evaluate the results of surgical management of reconstruction of severe anophthalmic orbits and atresic eye sockets with vascular anastomosed free dorsalis pedis flap transplantation. There were 5 patients (5 eyes) who underwent reconstructive surgery of severe anophthalmic orbits and atresic eye sockets after enucleation and irradiation of retinoblastoma in our hospital during the 3 years. All patients had enucleation and irradiation immediately after the retinoblastoma was diagnosed and had never worn artificial eyes because of the atresic eye sockets. Vascular anastomosed free dorsalis pedis flaps, whose dimensions were typically 6.5 × 5.5 cm(2), were transplanted to reconstruct the severe anophthalmic orbits and atresic eye sockets. The donor sites were covered by free abdominal skin flaps. All the vascular anastomosed free dorsalis pedis flaps were valid after more than 6 months of follow-up. And then all the 5 patients underwent secondary autogenous dermal fat implantation to augment the supraorbital area depression. After the 2-stage reconstruction surgery, the dimensions of the eye sockets were adequate, and all patients were able to wear their prosthesis and had a satisfactory cosmetic result. Implantation of alloplastic materials is not recommended because of insufficient blood supply of the irradiated orbital area.

  17. The Internal Pudendal Artery Perforator Thigh Flap: A New Freestyle Pedicle Flap for the Ischial Region

    Directory of Open Access Journals (Sweden)

    Ichiro Hashimoto, MD

    2014-05-01

    Conclusions: The perforator vessels of the internal pudendal artery are very close to the ischial tuberosity. Blood flow to the flap is reliable when careful debridement of the pressure sore is performed. The iPap thigh flap is a new option for soft-tissue defects in the ischial region, including ischial pressure sores.

  18. Psychophysical basis for maximum pushing and pulling forces: A review and recommendations.

    Science.gov (United States)

    Garg, Arun; Waters, Thomas; Kapellusch, Jay; Karwowski, Waldemar

    2014-03-01

    The objective of this paper was to perform a comprehensive review of psychophysically determined maximum acceptable pushing and pulling forces. Factors affecting pushing and pulling forces are identified and discussed. Recent studies show a significant decrease (compared to previous studies) in maximum acceptable forces for males but not for females when pushing and pulling on a treadmill. A comparison of pushing and pulling forces measured using a high inertia cart with those measured on a treadmill shows that the pushing and pulling forces using high inertia cart are higher for males but are about the same for females. It is concluded that the recommendations of Snook and Ciriello (1991) for pushing and pulling forces are still valid and provide reasonable recommendations for ergonomics practitioners. Regression equations as a function of handle height, frequency of exertion and pushing/pulling distance are provided to estimate maximum initial and sustained forces for pushing and pulling acceptable to 75% male and female workers. At present it is not clear whether pushing or pulling should be favored. Similarly, it is not clear what handle heights would be optimal for pushing and pulling. Epidemiological studies are needed to determine relationships between psychophysically determined maximum acceptable pushing and pulling forces and risk of musculoskeletal injuries, in particular to low back and shoulders.

  19. The Versatile Extended Thoracodorsal Artery Perforator Flap for Breast Reconstruction

    DEFF Research Database (Denmark)

    Jacobs, Jordan; Børsen-Koch, Mikkel; Gunnarsson, Gudjon L.

    2016-01-01

    complications occurred in 10 of 106 (10%) cases and included hematoma (1/108), venous congestion (2/108), and partial flap necrosis (7/108). The reconstructive goal was achieved in 103 of 106 (97%) flaps. CONCLUSIONS: The TAP flap is a pedicled, fasciocutaneous flap that can be used for total breast...

  20. Suspension Bridge Flutter for Girder with Separate Control Flaps

    DEFF Research Database (Denmark)

    Huynh, T.; Thoft-Christensen, Palle

    Active vibration control of long span suspension bridge flutter using separated control flaps (SFSC) has shown to increase effectively the critical wind speed of bridges. In this paper, an SFSC calculation based on modal equations of the vertical and torsional motions of the bridge girder including...... the flaps is presented. The length of the flaps attached to the girder, the flap configuration and the flap rotational angles are parameters used to increase the critical wind speed of the bridge. To illustrate the theory a numerical example is shown for a suspension bridge of 1000m+2500m+1000m span based...... on the Great Belt Bridge streamlined girder....

  1. Soave transanal one-stage endorectal pull-through in the treatment of Hirschsprung′s disease of the child above two-year-old: A report of 20 cases

    Directory of Open Access Journals (Sweden)

    Amine Ksia

    2013-01-01

    Full Text Available Background: The definitive treatment of Hirschsprung′s disease is the removal of the aganglionic bowel by a pull-through surgery. In most cases, this surgery is performed in infancy or in the neonatal period as presentation in older children and adulthood is uncommon. Materials and Methods: It is a retrospective study of 20 patients above two-year-old who underwent a transanal Soave one-stage endorectal pull-through procedure for Hirschsprung′s disease between January 2002 and December 2010. Results: Twenty patients were recruited in this study. Fourteen were males and six were females. Patient ages ranged from 2 to 14 years (median age: five years and three months. All patients presented with persistent constipation and abdominal distension. Two of them had an intestinal obstruction that required colostomy. Ten patients (50% had a recto-sigmoid Hirschsprung′s disease. All patients were operated on using a Soave one-stage endorectal pull-through procedure. The laparoscopy was necessary during the pull-through in three cases. The average duration of the intervention was 240 minutes. That represents almost the double of the duration of the same procedure in newborns and infants in our department (130 minutes. Early postoperative complications included one case of anastomosis leakage and one case of intussusception. Late postoperative complications were perineum irritation in five cases (25%, anal stenosis in four cases (20% and enterocolitis in one case (5%. None of our patients developed fecal incontinence. Soiling was reported in four cases (20%. There was no death. Conclusion: Soave transanal one-stage endorectal pull-through is safely feasible in children of more than two years of age. Laparoscopy may be necessary whenever there are difficulties in the pull-through.

  2. Push-pull quinoidal porphyrins.

    Science.gov (United States)

    Smith, Martin J; Blake, Iain M; Clegg, William; Anderson, Harry L

    2018-05-01

    A family of push-pull quinoidal porphyrin monomers has been prepared from a meso-formyl porphyrin by bromination, thioacetal formation, palladium-catalyzed coupling with malononitrile and oxidation with DDQ. Attempts at extending this synthesis to a push-pull quinoidal/cumulenic porphyrin dimer were not successful. The crystal structures of the quinoidal porphyrins indicate that there is no significant contribution from singlet biradical or zwitterionic resonance forms. The crystal structure of an ethyne-linked porphyrin dimer shows that the torsion angle between the porphyrin units is only about 3°, in keeping with crystallographic results on related compounds, but contrasting with the torsion angle of about 35° predicted by computational studies. The free-base quinoidal porphyrin monomers form tightly π-stacked layer structures, despite their curved geometries and bulky aryl substituents.

  3. Reconstruction of radionecrotic ulcer using a myocutaneous flap

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Okano, Shinji; Iwasaki, Yasumasa; Mori, Tamotsu; Miyamoto, Yoshihiro; Shigeki, Sadayuki

    1990-01-01

    Problems in the surgical treatment of radionecrotic ulcers, using a myocutaneous flap, have been reviewed in 21 patients. These problems included poor wound healing, radiation damage to important nerves and vessels there by making dissection difficult, malignant changes, infections, continuing necrosis of the tissue, and bleeding during surgery and secondary hemorrhaging. The use of a myocutaneous flap has many advantages when compared with conventional flaps and free skin grafts in the reconstruction of radionecrotic ulcers. Flap survival was good, but an incomplete excision of the ulcer delayed primary wound healing. Therefore, complete excision of the radionecrotic ulcer is imperative. (author)

  4. Pushing and pulling in relation to musculoskeletal complaints

    NARCIS (Netherlands)

    Hoozemans, M. J M; Van Der Beek, Allard J.; Frings-Dresen, M. H. W.

    2000-01-01

    The first cross-sectional analyses are presented of a longitudinal study regarding the relationship between pushing and pulling and musculoskeletal disorders. Workers exposed to pushing and pulling and workers who had administrative tasks received a questionnaire. A significant association between

  5. [Design on tester of pull-out force for orthodontic micro implant].

    Science.gov (United States)

    Su, He; Wu, Pei; Wang, Huiyuan; Chen, Yan; Bao, Xuemei

    2013-09-01

    A special device for measuring the pull-out force of orthodontic micro implant was designed, which has the characteristics of simple construction and easy operation, and can be used to detect the pull-out-force of orthodontic micro implant. The tested data was stored and analyzed by a computer, and as the results, the pull-out-force curve, maximum pull-out force as well as average pull-out force were outputted, which was applied in analyzing or investigating the initial stability and immediate loading property of orthodontic micro implant.

  6. Island Latissimus Dorsi Muscle Flap and a Perforator Flap in Repairing Post-Gunshot Thoracic Spine CSF Fistula: Case Presentation

    Directory of Open Access Journals (Sweden)

    Nangole F. Wanjala

    2015-01-01

    Full Text Available Persistent posttraumatic CSF fluid leakage may present a challenge to manage. Failure to address the leakage may result in complications such as meningitis, septicemia, radiculopathy, muscle weakness, and back pains. While the majority of the leakages may be managed conservatively, large dura defects as a result of gunshot wounds or motor vehicle accidents are best managed by surgical interventions. This may range from primary closure of the defect to fascial grafts, adhesive glues, and flaps. We present our experience with the use of flaps in a patient who had sustained such wounds in the thoracic spine. An island latissimus dorsal flap and a perforator fasciocutaneous flap were used to close the defect. Postoperatively the patient recovered well and the wounds healed without any complications.

  7. [Repair of pressure sores over ischial tuberosity with long head of biceps femoris muscle flap combined with semi-V posterior thigh fasciocutaneous flap].

    Science.gov (United States)

    Hai, Heng-lin; Shen, Chuan-an; Chai, Jia-ke; Li, Hua-tao

    2012-02-01

    To explore the clinical effect of transplantation of the long head of biceps femoris muscle flap in combination with semi-V posterior thigh fasciocutaneous flap for repair of pressure sores over ischial tuberosity. Eight patients with 10 deep pressure sores over ischial tuberosity were admitted to the First Affiliated Hospital to the PLA General Hospital and the 98th Hospital of PLA from April 2004 to June 2010. The wounds measured from 2 cm × 2 cm to 6 cm × 4 cm were covered with the long head of biceps femoris muscle flap and semi-V posterior thigh fasciocutaneous flap (ranged from 10 cm × 6 cm to 13 cm × 8 cm). The condition of flaps was observed and followed up for a long time. All flaps survived. Nine wounds healed by first intention. Subcutaneous accumulation of fluids occurred in one wound with formation of a sinus at drainage site, and it healed after dressing change for 25 days. Patients were followed up for 7 to 34 months. Sore recurred in one patient 9 months after surgery, and it was successfully repaired with the same flap for the second time. Flaps in the other 7 patients appeared satisfactory with soft texture and without ulceration. This combined flap is easy in formation and transfer, and it causes little side injury with good resistance against pressure. It is a new method for repair of pressure sore over sacral region.

  8. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).

    Science.gov (United States)

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.

  9. An Elongated Leading Edge Facilitates Rotation Flap Closure: In Vivo Demonstration.

    Science.gov (United States)

    Lichon, Vanessa; Barbosa, Naiara; Gomez, Doug; Goldman, Glenn

    2016-01-01

    Variation in the design of a rotation flap may affect wound closure tension. Lengthening the leading edge of a rotation flap has been a method of reducing the tension of closure in the primary motion. An in vitro study negating this tenant has been published. The authors set out to design an in vivo experiment to determine if lengthening the leading edge of a rotation flap has the effect of reducing closure tension in the primary motion of the repair. An animal study approved by Institutional Animal Care and Use Committee was undertaken in a pig model. A tension-measuring apparatus was designed using Teflon-coated wires and digital tensiometers. Rotation flaps of a standard design and with elongated leading edges were incised on the flanks of pigs under general anesthesia. Flap closure tensions were measured at points along the leading edge of the flap and in the secondary motion. Elongating the leading edge of a flap led to a statistically significant reduction in closure tension in the primary motion of the flap and at the flap tip. The secondary motion closure tensions were essentially unaffected. The authors confirm that elongating the leading edge of a standard rotation flap will reduce closure tension in the primary flap motion.

  10. The effect of atorvastatin on survival of rat ischemic flap

    Directory of Open Access Journals (Sweden)

    Jian-Xun Chen

    2013-04-01

    Full Text Available Management of skin avulsion with tissue exposure is a challenge for plastic surgeons. Clinical observations have suggested that longer survival of skin flap prevents further contamination and infection. Less well known is the role of atorvastatin in avulsion skin flap. Therefore, we attempted to determine whether atorvastatin could alleviate avulsion skin flap in a rat model. Twenty male Sprague–Dawley rats were randomized into two groups: the atorvastatin group and the control. Before operation, each rat received an initial blood perfusion scan as baseline data. Then, each rat received an operation of skin flap incision, elevation, and resuturing to the original position under general anesthesia. Another blood perfusion scan was performed on each rat 30 minutes, 4 days, and 7 days postoperatively. On the 7th postoperative day, the necrotic area of skin flap was measured as the skin flap viability. The skin flap tissues at 2.5 and 5 cm distal to the skin flap base were collected for histopathological analysis, as well as measurement of vascular endothelial growth factor (VEGF mRNA expression, and vascular density. Compared with 30 minutes postoperation, there was a significant increase in the ratio of skin flap blood perfusion on the 4th and 7th days postoperation in both control and atorvastatin groups (p<0.05. Compared with the control group, there was a significant decrease in necrotic area, significant increase in ratio of skin flap blood perfusion on postoperation days 4 and 7, and significant increase in vascular density under high field at 2.5 cm distal to the base of skin flap in the atorvastatin group (p<0.05. The VEGF121 and VEGF165 mRNA expression at 2.5 cm distal to the base of skin flap differed significantly between the two groups (p<0.05. Compared with the control group, atorvastatin treatment improved skin flap blood perfusion, vascular density, and necrotic area dependent on VEGF mRNA expression.

  11. Postirradiation flap infection about the oral cavity

    International Nuclear Information System (INIS)

    Cabbabe, E.B.; Herbold, D.R.; Sunwoo, Y.C.; Baroudi, I.F.

    1983-01-01

    Postirradiation alteration of oral flora is well documented in the literature. Infection as a complication leading to partial or complete loss of a flap used to reconstruct a defect in the oral cavity is a worrisome outcome. We describe how a flap that was judged clinically to be viable became overwhelmingly infected with the Klebsiella oxytoca, an oral cavity pathogen encountered in this patient following irradiation. Local and systemic changes led to detachment of the flap. This complication may be explained, in view of the absence of venous congestion or arterial ischemia both clinically and pathologically, by the proven contamination of the flap by the Klebsiella pathogen. Local factors resulted in lower resistance and subsequent overwhelming infection. Discussion of the case, review of pertinent literature, and proposed solutions are presented

  12. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK

    Directory of Open Access Journals (Sweden)

    Tsai TH

    2017-04-01

    Full Text Available Tsung-Han Tsai,1 Kai-Ling Peng,1 Chien-Jen Lin2 1Department of Ophthalmology, 2Department of Radiology, Chi Mei Medical Center, Tainan, Taiwan Background: Laser in situ keratomileusis (LASIK is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK.Case presentation: A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of −0.75 D to 1.0 D ×175° in her right eye 1 month later.Literature review: We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014.Conclusion: Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could

  13. A Single Amino Acid Difference between Mouse and Human 5-Lipoxygenase Activating Protein (FLAP) Explains the Speciation and Differential Pharmacology of Novel FLAP Inhibitors.

    Science.gov (United States)

    Blevitt, Jonathan M; Hack, Michael D; Herman, Krystal; Chang, Leon; Keith, John M; Mirzadegan, Tara; Rao, Navin L; Lebsack, Alec D; Milla, Marcos E

    2016-06-10

    5-Lipoxygenase activating protein (FLAP) plays a critical role in the metabolism of arachidonic acid to leukotriene A4, the precursor to the potent pro-inflammatory mediators leukotriene B4 and leukotriene C4 Studies with small molecule inhibitors of FLAP have led to the discovery of a drug binding pocket on the protein surface, and several pharmaceutical companies have developed compounds and performed clinical trials. Crystallographic studies and mutational analyses have contributed to a general understanding of compound binding modes. During our own efforts, we identified two unique chemical series. One series demonstrated strong inhibition of human FLAP but differential pharmacology across species and was completely inactive in assays with mouse or rat FLAP. The other series was active across rodent FLAP, as well as human and dog FLAP. Comparison of rodent and human FLAP amino acid sequences together with an analysis of a published crystal structure led to the identification of amino acid residue 24 in the floor of the putative binding pocket as a likely candidate for the observed speciation. On that basis, we tested compounds for binding to human G24A and mouse A24G FLAP mutant variants and compared the data to that generated for wild type human and mouse FLAP. These studies confirmed that a single amino acid mutation was sufficient to reverse the speciation observed in wild type FLAP. In addition, a PK/PD method was established in canines to enable preclinical profiling of mouse-inactive compounds. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  14. Blood Perfusion in Human Eyelid Skin Flaps Examined by Laser Speckle Contrast Imaging-Importance of Flap Length and the Use of Diathermy.

    Science.gov (United States)

    Nguyen, Cu Dinh; Hult, Jenny; Sheikh, Rafi; Tenland, Kajsa; Dahlstrand, Ulf; Lindstedt, Sandra; Malmsjö, Malin

    2017-10-11

    It is well known that blood perfusion is important for the survival of skin flaps. As no study has been conducted to investigate how the blood perfusion in human eyelid skin flaps is affected by the flap length and diathermy, the present study was carried out to investigate these in patients. Fifteen upper eyelids were dissected as part of a blepharoplastic procedure, releasing a 30-mm long piece of skin, while allowing the 5 mm wide distal part of the skin to remain attached, to mimic a skin flap (hereafter called a "skin flap"). Blood perfusion was measured before and after repeated diathermy, using laser speckle contrast imaging. Blood perfusion decreased from the base to the tip of the flap: 5 mm from the base, the perfusion was 69%, at 10 mm it was 40%, at 15 mm it was 20%, and at 20 mm it was only 13% of baseline values. Diathermy further decreased blood perfusion (measured 15 mm from the base) to 13% after applying diathermy for the first time, to 6% after the second and to 4% after the third applications of diathermy. Blood perfusion falls rapidly with distance from the base of skin flaps on the human eyelid, and diathermy reduces blood perfusion even further. Clinically, it may be advised that flaps with a width of 5 mm be no longer than 15 mm (i.e., a width:length ratio of 1:3), and that the use of diathermy should be carefully considered.

  15. Electromyographical Comparison of a Traditional, Suspension Device, and Towel Pull-Up

    Directory of Open Access Journals (Sweden)

    Snarr Ronald L.

    2017-08-01

    Full Text Available Strengthening muscles of the back may have various implications for improving functions of daily living, aiding in the transfer of power in throwing, and assist in injury prevention of the shoulder complex. While several versions of the pull-up exist, there is currently no literature comparing their differences. The purpose of this investigation was to compare the electromyographical activity of the latissimus dorsi, posterior deltoid, middle trapezius, and biceps brachii while performing three variations of the pull-up. Resistance-trained men and women (n =15, age = 24.87 ± 6.52 years participated in this study by performing traditional pull-ups, suspension device pull-ups, and towel pull-ups in a randomized fashion. Each pull-up was performed for three repetitions with a 1.5 bi-acromial grip-width for each participant. Normalized (%MVC electromyographical values were recorded for each muscle group during each pull-up variation. No significant differences existed within the latissimus dorsi, biceps brachii or posterior deltoid between any of the exercises. For the middle trapezius, towel pull-ups provided significantly lower muscle activity than the traditional pull-up, while no differences between suspension pull-ups and the other variations occurred. In conclusion, only one muscular difference existed between the exercise variations and all versions examined provided electromyographical values, determined by current literature, to invoke a sufficient stimulus to promote increases in muscle strength and hypertrophy. Although further research is needed, practitioners can be confident when programming any of the movement variations examined when attempting to elicit adaptations of muscular strength and hypertrophy.

  16. "Apron" flap and re-creation of the inframammary fold following TRAM flap breast reconstruction.

    Science.gov (United States)

    Amir, A; Silfen, R; Hauben, D J

    2000-03-01

    To the best of our knowledge, the recreation of an inframammary fold after TRAM flap breast reconstruction has not yet been described. This article offers a technique for the creation of an inframammary fold as a secondary procedure. The technique has been performed thus far in two patients with good aesthetic outcomes and no postoperative complications. It may also be suitable for adding bulk to the TRAM flap, especially in bilateral breast reconstruction, and for other minor chest deformities.

  17. A standardized model for predicting flap failure using indocyanine green dye

    Science.gov (United States)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  18. Clinical application of scrotal flap on penis lengthening.

    Science.gov (United States)

    Zhuo, Qinqiang; Li, Shirong; Wu, Julong; Wang, Zhenxiang; Yang, Dongyun; Tao, Ling

    2009-03-01

    To investigate the clinical application of the scrotal flap on penis lengthening. One hundred and fifty-two patients were operated using the scrotal flap from July 1998 to January 2008 at the Department of Plastic and Aesthetic, Surgery Southwest Hospital, Chongqing, China. The procedure consisted of designing a positive sign shaped incision 1.5cm above the root of the penis, dissect and release the superficial suspensory ligament and part of the deep suspensory ligament, then cover the elongated cavernosum with proper scrotal flap. Six-month to 5-year follow-up showed that all patients were satisfied with the good contour and function of the penis. The operation was successful. The method of using scrotal flap on penis lengthening has the following advantages: simple operation, reliable blood supply of the flap, one-stage operation, and satisfactory postoperative results. It is a preferable operation technique for penis lengthening.

  19. Digital artery perforator (DAP) flaps: modifications for fingertip and finger stump reconstruction.

    Science.gov (United States)

    Mitsunaga, Narushima; Mihara, Makoto; Koshima, Isao; Gonda, Koichi; Takuya, Iida; Kato, Harunosuke; Araki, Jun; Yamamoto, Yushuke; Yuhei, Otaki; Todokoro, Takeshi; Ishikawa, Shoichi; Eri, Uehara; Mundinger, Gerhard S

    2010-08-01

    Various fingertip reconstructions have been reported for situations where microsurgical finger replantation is impossible. One method is the digital artery perforator (DAP) flap. Herein we report 13 DAP flaps for fingertip and finger stump reconstruction following traumatic finger amputations, highlighting modifications to the originally described DAP flap. From October 1998 to December 2007, a total of 13 fingers (11 patients) underwent fingertip and finger stump reconstruction with modified DAP flaps following traumatic finger amputations. We performed six adipocutaneous flaps, three adipose-only flaps, two supercharged flaps and two extended flaps. Flap size ranged from 1.44 to 8 cm(2) (average 3.25 cm(2)). All flaps survived completely with the exception of partial skin necrosis in two cases. One of these cases required debridement and skin grafting. Our initial three cases used donor-site skin grafting. The donor site was closed primarily in the 10 subsequent cases. No patients showed postoperative hypersensitivity of repaired fingertips. Semmes-Weinstein (SW) test result for flaps including a digital nerve branch did not differ from those without (average 4.07 vs. 3.92). Modified DAP flaps allow for preservation of digital length, volume and finger function. They can be raised as adiposal-only flaps or extended flaps and supercharged through perforator-to-perforator anastomoses. The donor defect on the lateral pulp can be closed primarily or by skin grafting. For traumatic fingertip and finger stump reconstructions, DAP flaps deliver consistent aesthetic and functional results. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Biomechanical corneal changes induced by different flap thickness created by femtosecond laser

    Directory of Open Access Journals (Sweden)

    Fabricio W. Medeiros

    2011-01-01

    Full Text Available OBJECTIVE: To evaluate the impact of the creation of corneal flaps at different thicknesses on the biomechanical properties of swine corneas. METHOD: Twelve swine eyes were obtained to form two groups: 100 μm flap thickness and 300 μm flap thickness. Each eye was submitted to the following examinations: raster topography to investigate corneal curvature alterations, ocular response analyzer to investigate corneal hysteresis change, optical coherence tomography to measure central corneal and flap thickness and sonic wave propagation velocity as a measure of stiffness, before and immediately after flap creation. After flap amputation, surface wave velocity measurements were repeated. RESULTS: Measured flap thicknesses were statistically different for thin and thick flap groups, with an average of 108.5 + 6.9 and 307.8 + 11.5 μm respectively. Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group. With thicker flaps, both parameters decreased significantly from 8.0 +1.0 to 5.1 +1.5 mmHg and from 8.2 + 1.6 to 4.1 +2.5 mmHg respectively. Simulated keratometry values increased in the thick flap group (from 39.5 + 1 D to 45.9+1.2 D after flap creation but not in the thin flap group (from 40.6 + 0.6 D to 41.4+ 1.0 D. Regarding surface wave velocity analysis, the surgical procedures induced statistically lower results in some positions. CONCLUSION: In the experimental conditions established by this model, thicker flaps presented a greater biomechanical impact on the cornea.

  1. Tuberculosis abdominal Abdominal tuberculosis

    OpenAIRE

    T. Rubio; M. T. Gaztelu; A. Calvo; M. Repiso; H. Sarasíbar; F. Jiménez Bermejo; A. Martínez Echeverría

    2005-01-01

    La tuberculosis abdominal cursa con un cuadro inespecífico, con difícil diagnóstico diferencial respecto a otras entidades de similar semiología. Presentamos el caso de un varón que ingresa por presentar dolor abdominal, pérdida progresiva y notoria de peso corporal y fiebre de dos meses de evolución. El cultivo de la biopsia de colon mostró presencia de bacilo de Koch.Abdominal tuberculosis develops according to a non-specific clinical picture, with a difficult differential diagnosis with re...

  2. Characteristics and phenomenology of hair-pulling: an exploration of subtypes.

    Science.gov (United States)

    du Toit, P L; van Kradenburg, J; Niehaus, D J; Stein, D J

    2001-01-01

    This study was designed to detail the demographic and phenomenological features of adult chronic hair-pullers. Key possible subtypes were identified a priori. On the basis of the phenomenological data, differences between the following possible subtypes were investigated: hair-pullers with and without DSM-IV trichotillomania (TTM), oral habits, automatic versus focused hair-pulling, positive versus negative affective cues prior to hair-pulling, comorbid self-injurious habits, obsessive-compulsive disorder (OCD), and tics. Forty-seven participants were drawn from an outpatient population of chronic adult hair-pullers. A structured interview that focused on hair-pulling and associated behaviors was administered to participants. Six of the participants (12.8%) were male, and 41 (87.7%) were female. A large number of hair-pullers (63.8%) had comorbid self-injurious habits. A greater proportion of male hair-pullers had comorbid tics when compared with females. Certain subgroups of chronic hair-pullers (e.g., hairpullers with or without automatic/focused hair-pulling, comorbid self-injurious habits, and oral habits) were found to differ on a number of phenomenological and hair-pulling characteristics. However, differences between other possible subgroups (e.g., hair-pullers with or without DSM-IV TTM, comorbid OCD, and negative versus positive affective cues) may reflect greater severity in hair-pulling symptomatology rather than distinct subtypes of chronic hair-pulling. The findings of the present study also indicated that chronic hair-pulling (even in cases where DSM-IV criteria for TTM were not met) has a significant impact on quality of life. The present study provided limited support for the existence of possible subtypes of chronic hair-pulling. Recommendations are made for further investigations into such subtypes. Copyright 2001 by W.B. Saunders Company

  3. Ornithopter Type Flapping Wings for Autonomous Micro Air Vehicles

    Directory of Open Access Journals (Sweden)

    Sutthiphong Srigrarom

    2015-05-01

    Full Text Available In this paper, an ornithopter prototype that mimics the flapping motion of bird flight is developed, and the lift and thrust generation characteristics of different wing designs are evaluated. This project focused on the spar arrangement and material used for the wings that could achieves improved performance. Various lift and thrust measurement techniques are explored and evaluated. Various wings of insects and birds were evaluated to understand how these natural flyers with flapping wings are able to produce sufficient lift to fly. The differences in the flapping aerodynamics were also detailed. Experiments on different wing designs and materials were conducted and a paramount wing was built for a test flight. The first prototype has a length of 46.5 cm, wing span of 88 cm, and weighs 161 g. A mechanism which produced a flapping motion was fabricated and designed to create flapping flight. The flapping flight was produced by using a single motor and a flexible and light wing structure. A force balance made of load cell was then designed to measure the thrust and lift force of the ornithopter. Three sets of wings varying flexibility were fabricated, therefore lift and thrust measurements were acquired from each different set of wings. The lift will be measured in ten cycles computing the average lift and frequency in three different speeds or frequencies (slow, medium and fast. The thrust measurement was measure likewise but in two cycles only. Several observations were made regarding the behavior of flexible flapping wings that should aid in the design of future flexible flapping wing vehicles. The wings angle or phase characteristic were analyze too and studied. The final ornithopter prototype weighs only 160 g, has a wing span of 88.5 cm, that could flap at a maximum flapping frequency of 3.869 Hz, and produce a maximum thrust and lift of about 0.719 and 0.264 N respectively. Next, we proposed resonance type flapping wing utilizes the near

  4. KOMPARASI SISTEM MANUFAKTUR PUSH DAN PULL MELALUI PENDEKATAN SIMULASI

    Directory of Open Access Journals (Sweden)

    Eric Wibisono

    2004-01-01

    Full Text Available Manufacturing systems that are often classified as push and pull often invite question: "How far do the differences between those two systems exist?" Many researches have been carried out but succinct answer to the above question is always difficult to reach. The difficulty roots from the variety of definition of the push and pull systems itself and also from the variety of complexity of a manufacturing system. This paper attempts to study the differences in performance between push and pull systems in a relatively simple model that consists of 4 serial processors with buffers located between these processors. Variations being modelled is on the setting of the system's load (high and low and the buffer size with performance being measured include machine utilization, number of outputs and mean flow time of jobs. The approach used is simulation using ProModel software as the tool. From the experiments it can be derived that buffer size turns out to be a very critical factor in system performance. Moreover, it is also proved that when the buffer size is large, push and pull systems do not differ significantly. Abstract in Bahasa Indonesia : Sistem manufaktur yang umumnya dikategorikan menjadi sistem push dan pull sering mengundang pertanyaan: "Seberapa jauh perbedaan dari kedua sistem tersebut ada?" Banyak penelitian telah dilakukan namun jawaban yang lugas atas pertanyaan tersebut sulit diperoleh. Kesulitan ini umumnya berakar dari beragamnya definisi sistem push dan pull itu sendiri serta variasi dari kompleksitas suatu sistem manufaktur. Makalah ini mencoba melihat perbedaan antara kinerja sistem push dan pull dalam suatu model sederhana yang terdiri dari 4 prosesor serial dengan buffer yang diletakkan di antara masing-masing prosesor tersebut. Variasi yang dilakukan adalah pada setting beban kerja sistem (padat dan ringan dan ukuran buffer dengan kinerja yang diukur adalah utilisasi mesin, jumlah output dan rata-rata waktu tinggal job

  5. Droplet ejection and sliding on a flapping film

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2017-03-01

    Full Text Available Water recovery and subsequent reuse are required for human consumption as well as industrial, and agriculture applications. Moist air streams, such as cooling tower plumes and fog, represent opportunities for water harvesting. In this work, we investigate a flapping mechanism to increase droplet shedding on thin, hydrophobic films for two vibrational cases (e.g., ± 9 mm and 11 Hz; ± 2 mm and 100 Hz. Two main mechanisms removed water droplets from the flapping film: vibrational-induced coalescence/sliding and droplet ejection from the surface. Vibrations mobilized droplets on the flapping film, increasing the probability of coalescence with neighboring droplets leading to faster droplet growth. Droplet departure sizes of 1–2 mm were observed for flapping films, compared to 3–4 mm on stationary films, which solely relied on gravity for droplet removal. Additionally, flapping films exhibited lower percentage area coverage by water after a few seconds. The second removal mechanism, droplet ejection was analyzed with respect to surface wave formation and inertia. Smaller droplets (e.g., 1-mm diameter were ejected at a higher frequency which is associated with a higher acceleration. Kinetic energy of the water was the largest contributor to energy required to flap the film, and low energy inputs (i.e., 3.3 W/m2 were possible. Additionally, self-flapping films could enable novel water collection and condensation with minimal energy input.

  6. The Versatile Naso-Labial Flaps in Facial Reconstruction

    International Nuclear Information System (INIS)

    El-Marakby, H.H.

    2005-01-01

    Surgical excision of tumors from the face may create a defect that is difficult to restore. Skin grafts can only cover superficial defects and has a natural tendency to contract and may not take properly. Also, because of the colour mismatch, it is not cosmetically identical to the face. The use of regional flaps such as the median forehead flaps are usually bulky, can not cover a wide range of facial reconstruction and usually require the donor area to be grafted. The naso-labial flaps are very useful and versatile local flaps, with robust vascularity that can be readily elevated without a delay. The flap can be superiorly based to reconstruct defects on the cheek, side wall or the dorsum of the nose, alae, collumula and the lower eye lid. Inferiorly based flaps can be used to reconstruct defects in the upper lip, anterior floor of the mouth and the lower lip. The flap can be turned over and used as a lining of the nose and the lip. Aim of the Study: In the current study we present our experience with utilization of the nasolabial flaps in facial reconstruction. We evaluated the indications, flap designs, technique, and complications. We will also assess the final functional and aesthetic results. Material and Methods: The study included 20 patients (12 males and 8 females) presented at the surgical department, National Cancer Institute (NCl) Cairo University with skin cancer at different areas of the face. Preoperative assessment includes. Assessment of the stage of the disease, the flap design and patient general condition. The mean age of the patients was 56.3±6 years (range ]6-62 years). Fifteen patients presented with basal cell carcinoma, 2 squamous cell carcinoma, one malignant melanoma, one keratoacanthoma, and one xeroderma pigmentosa. Nasal defects constituted 75% of cases, the rest were lower eye lid (2), one upper lip and one oral commisure beside a case of cheek reconstruction. There was no major complication; only one patient suffered a reactionary

  7. Edaravone enhances the viability of ischemia/reperfusion flaps.

    Science.gov (United States)

    Zhang, Dong-Yi; Kang, Shen-Song; Zhang, Zheng-Wen; Wu, Rui

    2017-02-01

    The purpose of the experiment was to study the efficacy of edaravone in enhancing flap viability after ischemia/reperfusion (IR) and its mechanism. Forty-eight adult male SD rats were randomly divided into 3 groups: control group (n=16), IR group (n=16), and edaravone-treated IR group (n=16). An island flap at left lower abdomen (6.0 cm×3.0 cm in size), fed by the superficial epigastric artery and vein, was created in each rat of all the three groups. The arterial blood flow of flaps in IR group and edaravone-treated IR group was blocked for 10 h, and then the blood perfusion was restored. From 15 min before reperfusion, rats in the edaravone-treated IR group were intraperitoneally injected with edaravone (10 mg/kg), once every 12 h, for 3 days. Rats in the IR group and control group were intraperitoneally injected with saline, with the same method and frequency as the rats in the edaravone-treated IR group. In IR group and edaravone-treated IR group, samples of flaps were harvested after reperfusion of the flaps for 24 h. In the control group, samples of flaps were harvested 34 h after creation of the flaps. The content of malondialdehyde (MDA) and activity of superoxide dismutase (SOD) were determined, and changes in organizational structure and infiltration of inflammatory cells were observed by hematoxylin-eosin (HE) staining, apoptotic cells of vascular wall were marked by terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) assay, and the apoptotic rate of cells in vascular wall was calculated. The ultrastructural changes of vascular endothelial cells were observed by transmission electron microscopy (TEM). Seven days after the operation, we calculated the flap viability of each group, and marked vessels of flaps by immunohistochemical staining for calculating the average number of subcutaneous vessels. The results showed that the content of MDA, the number of multicore inflammatory cells and apoptotic rate of cells in vascular wall

  8. Scrotal reconstruction with superomedial fasciocutaneous thigh flap

    Directory of Open Access Journals (Sweden)

    DANIEL FRANCISCO MELLO

    2018-02-01

    Full Text Available ABSTRACT Objective: to describe the use of a superomedial fasciocutaneous thigh flap for scrotal reconstruction in open areas secondary to the surgical treatment of perineal necrotizing fasciitis (Fournier’s gangrene. Methods: retrospective analysis of cases treated at the Plastic Surgery Service of Santa Casa de Misericórdia, São Paulo, from 2009 to 2015. Results: fifteen patients underwent scrotal reconstruction using the proposed flap. The mean age was 48.9 years (28 to 66. Skin loss estimates in the scrotal region ranged from 60 to 100%. Definitive reconstruction was performed on average 30.6 days (22 to 44 after the initial surgical treatment. The mean surgical time was 76 minutes (65 to 90 to obtain the flaps, bilateral in all cases. Flap size ranged from 10cm to 13cm in the longitudinal direction and 8cm to 10cm in the cross-sectional direction. The complication rate was 26.6% (four cases, related to the occurrence of segmental and partial dehiscence. Conclusion: the superomedial fasciocutaneous flap of thigh is a reliable and versatile option for the reconstruction of open areas in the scrotal region, showing adequate esthetic and functional results.

  9. Distally based sural neuro-fasciocutaneous perforator flap for foot and ankle reconstruction: Surgical modifications for flap pedicle and donor site closure without skin graft.

    Science.gov (United States)

    Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan

    2018-02-01

    The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.

  10. The Reliability of Pectorals Major Myocutaneous Flap in Head and Neck Reconstruction

    International Nuclear Information System (INIS)

    El-Marakby, H.H.

    2006-01-01

    Background: The pectorals major myocutaneous pedicle flap (PMMPF) has been considered to be the workhorse of pedicled flaps in head and neck reconstruction. Several series of PMMPF procedures in head and neck reconstruction have been reported in the literature. Even with the worldwide use of free flaps, the flap is still considered the mainstay head and neck reconstructive procedures in many centers. However, the flap is usually associated with a high incidence of complications in addition 10 its large bulk compared with the free fasciocutaneous flaps. Also the final functional and the aesthetic results are not comparable to free flaps head and neck reconstruction. Aim of the Study: The aim of the study is to evaluate the reliability of such flap in selected cases of head and neck reconstruction. The indications, technique, complications and the functional as well as the aesthetic results of the flap utilization were evaluated. Patients and Methods: Between May 2002 and May 2005 a 26 consecutive head and neck reconstruction procedures using the PMMPF were carried out on 25 patients at the Department of Surgery, National Cancer Institute, Cairo University. The indications for the flap use were defects due to resection of stage II-IV cancer in the head and neck region. The site, stage of the disease and the presence or absence of distant metastasis were assessed. Also preoperative assessment included the fitness of patients for such an extensive procedure. The total operative time, the need for blood transfusion, the postoperative complications, were all documented. The length of hospital stay, the follow-up of patients as well as the incidence of local recurrence underneath the flap were all evaluated. Results: Pectorals major myocutaneous pedicled flap reconstructions were used to reconstruct defects in the following sites: oral cavity (LO patients); oropharynx/hypopharynx, (5 patients); and neck or face (10 patients). Of the 26 PMMPF reconstructions. 22 flaps were

  11. Effects of hyperbaric oxygen and irradiation on experimental skin flaps in rats

    International Nuclear Information System (INIS)

    Nemiroff, P.M.; Merwin, G.E.; Brant, T.; Cassisi, N.J.

    1985-01-01

    This study investigated the effects of hyperbaric oxygen (HBO) and irradiation (RT) on experimental skin flaps in rats under varying conditions. Animals were assigned at random to 1 of 15 groups that represented all possible ordering effects of HBO, RT, and flap, as well as controls that included flap-only, RT-only, and HBO-only groups. Cranially based skin flaps measuring 3 x 9 cm were elevated on the dorsum. The surviving length was evaluated with fluorescein dye 7 days after the operation. Depending on the treatment condition, HBO was given either 48 hours or 24 hours before flap elevation, or within 4 hours or 48 hours after flap elevation. Rats receiving RT ( 60 Co) were given a single dose of 1000 rads to the dorsum. Results showed that all groups receiving HBO within 4 hours after flap elevation had significantly greater flap survival length, with as much as a 22% greater length of surviving flap. HBO given 48 hours before flap elevation also significantly improved flap survival over controls. RT appeared to have no immediate significant effect on flap survival. However, rats receiving RT, regardless of other factors, gained significantly less weight than did controls. Findings clearly indicate that, to be effective, HBO needs to be given as soon after surgery as possible

  12. Single crystal fibers growth of double lithium, lanthanium molybdate and adjustment of a micro-pulling down furnace for high vacuum setup

    International Nuclear Information System (INIS)

    Silva, Fernando Rodrigues da

    2013-01-01

    In this work we investigated crystal growth procedures aiming the development of single crystal fiber (SCF) for laser applications. For quality optimization in the fabrication of fluorides SCF a new growth chamber for a micro-pulling down furnace (μ-PD) was constructed targeting the fibers fabrication with strict atmosphere control (high vacuum, gas flux and static atmospheres). Simultaneously, the SCF growth process of rare earth double molybdates was studied. The growth of pure and Nd 3+ -doped SCF of LiLa(MoO 4 ) 2 (LLM) was studied in the range of 0,5 - 10mol% doping. The designed furnace growth chamber with controlled atmosphere was successfully constructed and tested under different conditions. Specially, it was tested with the growth of LiF SFC under CF 4 atmosphere showing the expected results. Transparent and homogeneous SCF of Nd:LLM were grown. In the pure fibers was observed facets formation, however, these defects were minimized after tuning of the growth parameters and additionally with the fibers doping. X-ray analysis showed the crystallization of a single phase (space group I4 1 /a); the optical coherence tomography showed the presence of scattering centers only in regions were some growth stability occurred due to the manual process control. The measured Nd 3+ distribution showed uniform incorporation, indicative of a segregation coefficient close to unity in LLM. The potential laser gain of the system was determined using a numerical solution of the rate equations system for the 805nm, CW pumping regime, showing the maximum laser emission gain at 1.064 μm for a Nd 3+ -doping of 5mol%. (author)

  13. INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.

    Science.gov (United States)

    Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J

    2016-02-01

    Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and

  14. Pull remanufacturing: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Levine, L.O.

    1992-09-01

    This paper describes how pull production methods have been applied to a manual transmission remanufacturing line at Tooele Army Depot in Utah. The paper emphasizes techniques for linking the control of disassembly and cleaning operations to the repair and assembly portions of the production system (PP&C). The primary objective is to show that production planning and control can be simplified when pull mechanisms are combined with shop floor improvements. One approach to applying MRP II to remanufacturing is to use a separate production schedule for the disassembly and assembly portions of the operation. This approach is primarily needed when managing the delivery and inventory of cores is critical to the successful operation of a remanufacturing organization. Because Army depots frequently have an adequate inventory of cores on hand (somewhere on-site), this requirement is usually less significant. Therefore, it is possible to eliminate the use of a master production schedule for disassembly and rely on pull linkages from the repair and assembly operations to control the activity of the disassembly and cleaning operations. In remanufacturing environments having multiple products and adequate buffers of core inventory, effective coordination of disassembly and cleaning functions with assembly production requirements becomes a key production control issue.

  15. Pull remanufacturing: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Levine, L.O.

    1992-09-01

    This paper describes how pull production methods have been applied to a manual transmission remanufacturing line at Tooele Army Depot in Utah. The paper emphasizes techniques for linking the control of disassembly and cleaning operations to the repair and assembly portions of the production system (PP C). The primary objective is to show that production planning and control can be simplified when pull mechanisms are combined with shop floor improvements. One approach to applying MRP II to remanufacturing is to use a separate production schedule for the disassembly and assembly portions of the operation. This approach is primarily needed when managing the delivery and inventory of cores is critical to the successful operation of a remanufacturing organization. Because Army depots frequently have an adequate inventory of cores on hand (somewhere on-site), this requirement is usually less significant. Therefore, it is possible to eliminate the use of a master production schedule for disassembly and rely on pull linkages from the repair and assembly operations to control the activity of the disassembly and cleaning operations. In remanufacturing environments having multiple products and adequate buffers of core inventory, effective coordination of disassembly and cleaning functions with assembly production requirements becomes a key production control issue.

  16. Aesthetic refinements and reoperative procedures following 370 consecutive DIEP and SIEA flap breast reconstructions: important considerations for patient consent.

    Science.gov (United States)

    Enajat, Morteza; Smit, Jeroen M; Rozen, Warren M; Hartman, Ed H M; Liss, Anders; Kildal, Morten; Audolfsson, Thorir; Acosta, Rafael

    2010-06-01

    Breast reconstruction often requires multiple operations. In addition to potential complications requiring reoperation, additional procedures are frequently essential in order to complete the reconstructive process, with aesthetic outcome and breast symmetry shown to be the most important factors in patient satisfaction. Despite the importance of these reoperations in decision-making and the consent process, a thorough review of the need for such operations has not been definitively explored. A review of 370 consecutive autologous breast reconstructions (326 patients) was undertaken, comprising 365 deep inferior epigastric artery perforator (DIEP) flaps and 5 superficial inferior epigastric artery (SIEA) flaps. The need for additional procedures for either complications or aesthetic refinement following initial breast reconstruction was assessed. Overall, there was an average of 1.06 additional interventions for every patient carried out after primary reconstructive surgery. Of 326 patients, 46 underwent early postoperative operations for surgical complications (0.17 additional operations per patient as a consequence of complications). Procedures for aesthetic refinement included those performed on the reconstructed breast, contralateral breast, or abdominal donor site. Procedures for aesthetic refinement included nipple reconstruction, nipple-areola complex tattooing, dog-ear correction, liposuction, lipofilling, scar revision, mastopexy, and reduction mammaplasty. While DIEP flap surgery for breast reconstruction provides favorable results, patients frequently require additional procedures to improve aesthetic outcomes. The need for reoperation is an important part of the consent process prior to reconstructive surgery, and patients should recognize the likelihood of at least one additional procedure following initial reconstruction.

  17. Staged abdominal re-operation for abdominal trauma.

    Science.gov (United States)

    Taviloglu, Korhan

    2003-07-01

    To review the current developments in staged abdominal re-operation for abdominal trauma. To overview the steps of damage control laparotomy. The ever increasing importance of the resuscitation phase with current intensive care unit (ICU) support techniques should be emphasized. General surgeons should be familiar to staged abdominal re-operation for abdominal trauma and collaborate with ICU teams, interventional radiologists and several other specialties to overcome this entity.

  18. Comparison of fluoroscopy-guided pull-type percutaneous radiological gastrostomy (pull-type-PRG) with conventional percutaneous radiological gastrostomy (push-type-PRG): clinical results in 253 patients

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang; Schneider, J.; Dueber, C.; Pitton, M.B. [University Medical Center of the Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany)

    2011-11-15

    To analyze the clinical results and complications of fluoroscopy guided internal-external pull-type percutaneous radiological gastrostomy (pull-type-PRG) and conventional external-internal percutaneous radiological gastrostomy (push-type-PRG). A total of 253 patients underwent radiological gastrostomy between January 2002 and January 2010. Data were collected retrospectively from radiology reports, Chart review of clinical notes, procedure reports, discharge summaries and subsequent hospital visits. Statistical analysis was performed to compare the two methods for gastrostomy with respect to peri-interventional aspects and clinical results. 128 patients received the Pull-type-PRG whereas the other 125 patients were served with the Push-type-PRG. Indications for gastrostomy were similar in these two groups. The most frequent indications for the both methods were stenotic oesophageal tumors or head/neck tumors (54.7% in pull-type-PRG, 68% in push-type-PRG). Gastrostomy procedures were successful in 98.3% in pull-type-PRG compared to 92% in push-type-PRG. There was no procedure-related mortality. Compared to Push-type-PRG, the peri-interventional complication rate was significantly reduced in pull-type-PRG (14.8% versus 34.4%, P = 0.002). Compared to the external-internal push-type-PRG, the internal-external Pull-type-PRG showed a high primary success rate and a decreased incidence of peri-interventional complications. (orig.)

  19. Comparison of fluoroscopy-guided pull-type percutaneous radiological gastrostomy (pull-type-PRG) with conventional percutaneous radiological gastrostomy (push-type-PRG): clinical results in 253 patients

    International Nuclear Information System (INIS)

    Yang, Yang; Schneider, J.; Dueber, C.; Pitton, M.B.

    2011-01-01

    To analyze the clinical results and complications of fluoroscopy guided internal-external pull-type percutaneous radiological gastrostomy (pull-type-PRG) and conventional external-internal percutaneous radiological gastrostomy (push-type-PRG). A total of 253 patients underwent radiological gastrostomy between January 2002 and January 2010. Data were collected retrospectively from radiology reports, Chart review of clinical notes, procedure reports, discharge summaries and subsequent hospital visits. Statistical analysis was performed to compare the two methods for gastrostomy with respect to peri-interventional aspects and clinical results. 128 patients received the Pull-type-PRG whereas the other 125 patients were served with the Push-type-PRG. Indications for gastrostomy were similar in these two groups. The most frequent indications for the both methods were stenotic oesophageal tumors or head/neck tumors (54.7% in pull-type-PRG, 68% in push-type-PRG). Gastrostomy procedures were successful in 98.3% in pull-type-PRG compared to 92% in push-type-PRG. There was no procedure-related mortality. Compared to Push-type-PRG, the peri-interventional complication rate was significantly reduced in pull-type-PRG (14.8% versus 34.4%, P = 0.002). Compared to the external-internal push-type-PRG, the internal-external Pull-type-PRG showed a high primary success rate and a decreased incidence of peri-interventional complications. (orig.)

  20. Accurate electrostatic and van der Waals pull-in prediction for fully clamped nano/micro-beams using linear universal graphs of pull-in instability

    Science.gov (United States)

    Tahani, Masoud; Askari, Amir R.

    2014-09-01

    In spite of the fact that pull-in instability of electrically actuated nano/micro-beams has been investigated by many researchers to date, no explicit formula has been presented yet which can predict pull-in voltage based on a geometrically non-linear and distributed parameter model. The objective of present paper is to introduce a simple and accurate formula to predict this value for a fully clamped electrostatically actuated nano/micro-beam. To this end, a non-linear Euler-Bernoulli beam model is employed, which accounts for the axial residual stress, geometric non-linearity of mid-plane stretching, distributed electrostatic force and the van der Waals (vdW) attraction. The non-linear boundary value governing equation of equilibrium is non-dimensionalized and solved iteratively through single-term Galerkin based reduced order model (ROM). The solutions are validated thorough direct comparison with experimental and other existing results reported in previous studies. Pull-in instability under electrical and vdW loads are also investigated using universal graphs. Based on the results of these graphs, non-dimensional pull-in and vdW parameters, which are defined in the text, vary linearly versus the other dimensionless parameters of the problem. Using this fact, some linear equations are presented to predict pull-in voltage, the maximum allowable length, the so-called detachment length, and the minimum allowable gap for a nano/micro-system. These linear equations are also reduced to a couple of universal pull-in formulas for systems with small initial gap. The accuracy of the universal pull-in formulas are also validated by comparing its results with available experimental and some previous geometric linear and closed-form findings published in the literature.

  1. Treatment of ischial pressure sores with double adipofascial turnover flaps.

    Science.gov (United States)

    Lin, Haodong; Hou, Chunlin; Xu, Zhen; Chen, Aiming

    2010-01-01

    Despite a variety of flap reconstruction options, the ischium remains the most difficult pressure sore site to treat. This article describes the authors' successful surgical procedure for coverage of ischial ulcers using double adipofascial turnover flaps.After debridement, the adipofascial flaps are harvested both cephalad and caudal to the defect. The flaps are then turned over to cover the exposed bone in a manner so as to overlap the 2 flaps. The skin is then closed with sutures in 2 layers. A total of 15 patients with ischial sores were treated using this surgical procedure.The follow-up period ranged from 11 to 159 months, with a mean of 93.6 months. Overall, 86.7% of the flaps (13 of 15) healed primarily. One patient had a recurrent grade II ischial pressure sore again 11 months after the operation. The other 14 patients did not have a recurrence.Treatment of ischial pressure sores with adipofascial turnover flaps provides an easy, minimally invasive procedure, with preservation of future flap options, and a soft-tissue supply sufficient for covering the bony prominence and filling dead space. This technique is a reliable and safe reconstructive modality for the management of minor ischial pressure sores.

  2. Pushing, pulling and manoeuvring an industrial cart: a psychophysiological study.

    Science.gov (United States)

    Giagloglou, Evanthia; Radenkovic, Milan; Brankovic, Sasa; Antoniou, Panagiotis; Zivanovic-Macuzic, Ivana

    2017-09-18

    One of the most frequent manual occupational tasks involves the pushing and pulling of a cart. Although several studies have associated health risks with pushing and pulling, the effects are not clear since occupational tasks have social, cognitive and physical components. The present work investigates a real case of a pushing and pulling occupational task from a manufacturing company. The study initially characterizes the case in accordance with Standard No. ISO 11228-2:2007 as low risk. An experiment with 14 individuals during three modalities of pushing and pulling was performed in order to further investigate the task with the application of electrophysiology. At the end, a simple questionnaire was given. The results show electrophysiological differences among the three modalities of pushing and pulling, with a major difference between action with no load and fully loaded with a full range of motions on the cart to handle.

  3. Development of an Extracorporeal Perfusion Device for Small Animal Free Flaps.

    Directory of Open Access Journals (Sweden)

    Andreas M Fichter

    Full Text Available Extracorporeal perfusion (ECP might prolong the vital storage capabilities of composite free flaps, potentially opening a wide range of clinical applications. Aim of the study was the development a validated low-cost extracorporeal perfusion model for further research in small animal free flaps.After establishing optimal perfusion settings, a specially designed extracorporeal perfusion system was evaluated during 8-hour perfusion of rat epigastric flaps followed by microvascular free flap transfer. Controls comprised sham-operation, ischemia and in vivo perfusion. Flaps and perfusate (diluted blood were closely monitored by blood gas analysis, combined laser Doppler flowmetry and remission spectroscopy and Indocyanine-Green angiography. Evaluations were complemented by assessment of necrotic area and light microscopy at day 7.ECP was established and maintained for 8 hours with constant potassium and pH levels. Subsequent flap transfer was successful. Notably, the rate of necrosis of extracorporeally perfused flaps (27% was even lower than after in vivo perfusion (49%, although not statistically significant (P = 0,083. After sham-operation, only 6% of the total flap area became necrotic, while 8-hour ischemia led to total flap loss (98%. Angiographic and histological findings confirmed these observations.Vital storage capabilities of microvascular flaps can be prolonged by temporary ECP. Our study provides important insights on the pathophysiological processes during extracorporeal tissue perfusion and provides a validated small animal perfusion model for further studies.

  4. Long-term follow-up of changing practice patterns in breast reconstruction due to increased use of tissue expanders and perforator flaps.

    Science.gov (United States)

    Manahan, Michele A; Prucz, Roni B; Shridharani, Sachin M; Baltodano, Pablo A; Rosson, Gedge D

    2014-11-01

    As the science of breast reconstruction evolves, significant changes in reconstruction strategies and outcomes are expected. The purpose of this study is to determine the changes in breast reconstruction trends and outcomes that occurred at a multidisciplinary academic institution during the last decade. We compared 265 patients over two distinct 6-month intervals separated by 5 years (2002 vs. 2007) and performed long-term follow-up (4.75 ± 3.38 years 2002, 2.99 ± 2.25 years 2007). We studied patients seeking prophylactic mastectomy, patients with early breast cancer, and patients with locally advanced disease. We analyzed demographic data, breast cancer history and treatment, type and timing of reconstruction, and complications. Implant to flap reconstruction ratio was 48:49 in 2002 and 76:102 in 2007. Use of transverse rectus abdominis myocutaneous flap declined from 57 to 4%; conversely, deep inferior epigastric perforator flap increased from 27 to 91% (P < 0.001). Correspondingly, donor site chronic pain (4 vs. 0, P = 0.012) and postoperative abdominal wall bulge (9 vs. 3, P = 0.004) rates decreased. Timing of reconstruction showed increased staged cases in 2007 compared to 2002 (P = 0.045). Post-final reconstruction radiation therapy was reduced in 2007 (P = 0.016), with subsequent lower rates of implant rupture (P < 0.001). At our institution and over the last decade, increasing staged reconstructions have successfully reduced the rates of post-final reconstruction radiotherapy with optimized outcomes. Contrary to national trends, the rates of autologous flap reconstructions have increased with reduced donor site morbidity. This suggests that academic breast reconstruction trends are independent from national trends. © 2014 Wiley Periodicals, Inc.

  5. A lining vomer flap for palate pushback in unilateral cleft palate repair.

    Science.gov (United States)

    Clavin, H D; Owsley, J Q

    1978-01-01

    A combinaation vomer mucoperiosteal flap and nasal floor mucoperiosteal flap is described which is used to achieve nasal coverage in unilateral cleft palate patients requiring pushbacks. A posteriorly based readily accessible vomer flap is raised on the cleft side and used as nasal lining for the palatal mucoperiosteal flap on the non-cleft side. On the cleft side, a symmetrically sized nasal floor flap is easily elevated under direct vision and used to cover the nasal aspect of the corresponding mucoperiosteal palatal flap.

  6. Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging

    NARCIS (Netherlands)

    Stemkens, Bjorn; Benkert, Thomas; Chandarana, Hersh; Bittman, Mark E.; Van den Berg, Cornelis A.T.; Lagendijk, Jan J.W.; Sodickson, Daniel K.; Tijssen, Rob H.N.; Block, Kai Tobias

    2017-01-01

    Non-Cartesian magnetic resonance imaging (MRI) sequences have shown great promise for abdominal examination during free breathing, but break down in the presence of bulk patient motion (i.e. voluntary or involuntary patient movement resulting in translation, rotation or elastic deformations of the

  7. Abdominal Tuberculosis Mimicking Intra-abdominal Malignancy: A ...

    African Journals Online (AJOL)

    TNHJOURNALPH

    BACKGROUND. Abdominal TB usually presents with nonspecific findings and may thus m.,mw a multitude of gastrointestinal disorders. Abdominal tuberculosis may therefore present as large and palpable intra-abdominal masses usually arising from lymphadenopathy which may mimic lymphomas and other malignancies.

  8. Abdominal tuberculosis mimicking intra-abdominal malignancy: A ...

    African Journals Online (AJOL)

    Background: Abdominal TB usually presents with nonspecific findings and may thus mimic a multitude of gastrointestinal disorders. Abdominal tuberculosis may therefore present as large and palpable intra-abdominal masses usually arising from lymphadenopathy which may mimic lymphomas and other malignancies.

  9. Freestyle multiple propeller flap reconstruction (jigsaw puzzle approach) for complicated back defects.

    Science.gov (United States)

    Park, Sung Woo; Oh, Tae Suk; Eom, Jin Sup; Sun, Yoon Chi; Suh, Hyun Suk; Hong, Joon Pio

    2015-05-01

    The reconstruction of the posterior trunk remains to be a challenge as defects can be extensive, with deep dead space, and fixation devices exposed. Our goal was to achieve a tension-free closure for complex defects on the posterior trunk. From August 2006 to May 2013, 18 cases were reconstructed with multiple flaps combining perforator(s) and local skin flaps. The reconstructions were performed using freestyle approach. Starting with propeller flap(s) in single or multilobed design and sequentially in conjunction with adjacent random pattern flaps such as fitting puzzle. All defects achieved tensionless primary closure. The final appearance resembled a jigsaw puzzle-like appearance. The average size of defect was 139.6 cm(2) (range, 36-345 cm(2)). A total of 26 perforator flaps were used in addition to 19 random pattern flaps for 18 cases. In all cases, a single perforator was used for each propeller flap. The defect and the donor site all achieved tension-free closure. The reconstruction was 100% successful without flap loss. One case of late infection was noted at 12 months after surgery. Using multiple lobe designed propeller flaps in conjunction with random pattern flaps in a freestyle approach, resembling putting a jigsaw puzzle together, we can achieve a tension-free closure by distributing the tension to multiple flaps, supplying sufficient volume to obliterate dead space, and have reliable vascularity as the flaps do not need to be oversized. This can be a viable approach to reconstruct extensive defects on the posterior trunk. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Experience with Perforator Based Flaps for Wound Cover of the Leg ...

    African Journals Online (AJOL)

    Background: Open fractures of the distal third of the tibia and fibular offer a challenge to the orthopedic surgeon because of skin coverage. The reconstructive surgeon's help is often required in trying to achieve this. There are several options: - local flap, free flap or a cross leg flap. Local flaps have always had limitations ...

  11. Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.

    Science.gov (United States)

    Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen

    2011-05-01

    To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  12. Nontraumatic abdominal emergencies: acute abdominal pain: diagnostic strategies

    International Nuclear Information System (INIS)

    Marincek, B.

    2002-01-01

    Common causes of acute abdominal pain include appendicitis, cholecystitis, bowel obstruction, urinary colic, perforated peptic ulcer, pancreatitis, diverticulitis, and nonspecific, nonsurgical abdominal pain. The topographic classification of acute abdominal pain (pain in one of the four abdominal quadrants, diffuse abdominal pain, flank or epigastric pain) facilitates the choice of the imaging technique. The initial radiological evaluation often consists of plain abdominal radiography, despite significant diagnostic limitations. The traditional indications for plain films - bowel obstruction, pneumoperitoneum, and the search of ureteral calculi - are questioned by helical computed tomography (CT). Although ultrasonography (US) is in many centers the modality of choice for imaging the gallbladder and the pelvis in children and women of reproductive age, CT is considered to be one of the most valued tools for triaging patients with acute abdominal pain. CT is particularly beneficial in patients with marked obesity, unclear US findings, bowel obstruction, and multiple lesions. The introduction of multidetector row CT (MDCT) has further enhanced the utility of CT in imaging patients with acute abdominal pain. (orig.)

  13. Nontraumatic abdominal emergencies: acute abdominal pain: diagnostic strategies

    Energy Technology Data Exchange (ETDEWEB)

    Marincek, B. [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2002-09-01

    Common causes of acute abdominal pain include appendicitis, cholecystitis, bowel obstruction, urinary colic, perforated peptic ulcer, pancreatitis, diverticulitis, and nonspecific, nonsurgical abdominal pain. The topographic classification of acute abdominal pain (pain in one of the four abdominal quadrants, diffuse abdominal pain, flank or epigastric pain) facilitates the choice of the imaging technique. The initial radiological evaluation often consists of plain abdominal radiography, despite significant diagnostic limitations. The traditional indications for plain films - bowel obstruction, pneumoperitoneum, and the search of ureteral calculi - are questioned by helical computed tomography (CT). Although ultrasonography (US) is in many centers the modality of choice for imaging the gallbladder and the pelvis in children and women of reproductive age, CT is considered to be one of the most valued tools for triaging patients with acute abdominal pain. CT is particularly beneficial in patients with marked obesity, unclear US findings, bowel obstruction, and multiple lesions. The introduction of multidetector row CT (MDCT) has further enhanced the utility of CT in imaging patients with acute abdominal pain. (orig.)

  14. Biomechanical study of the final push-pull in archery.

    Science.gov (United States)

    Leroyer, P; Van Hoecke, J; Helal, J N

    1993-02-01

    The purpose of this study was to analyse archery performance among eight archers of different abilities by means of displacement pull-hand measurements during the final push-pull phase of the shoot. The archers showed an irregular displacement negatively related to their technical level. Displacement signal analysis showed high power levels in both the 0-5 Hz and 8-12 Hz ranges. The latter peak corresponds to electromyographic tremor observed during a prolonged push-pull effort. The results are discussed in relation to some potentially helpful training procedures such as biofeedback and strength conditioning.

  15. The forked flap repair for hypospadias

    Directory of Open Access Journals (Sweden)

    Anil Chadha

    2012-01-01

    Full Text Available Context: Despite the abundance of techniques for the repair of Hypospadias, its problems still persist and a satisfactory design to correct the penile curvature with the formation of neourethra from the native urethral tissue or genital or extragenital tissues, with minimal postoperative complications has yet to evolve. Aim: Persisting with such an endeavor, a new technique for the repair of distal and midpenile hypospadias is described. Materials and Methods: The study has been done in 70 cases over the past 11 years. The "Forked-Flap" repair is a single stage method for the repair of such Hypospadias with chordee. It takes advantage of the rich vascular communication at the corona and capitalizes on the established reliability of the meatal based flip-flap. The repair achieves straightening of the curvature of the penis by complete excision of chordee tissue from the ventral surface of the penis beneath the urethral plate. The urethra is reconstructed using the native plate with forked flap extensions and genital tissue relying on the concept of meatal based flaps. Water proofing by dartos tissue and reinforcement by Nesbit′s prepucial tissue transfer completes the one stage procedure. Statistical Analysis: An analysis of 70 cases of this single stage technique of repair of penile hypospadias with chordee, operated at 3 to 5 years of age over the past 11 years is presented. Results and Conclusion: The Forked Flap gives comparable and replicable results; except for a urethrocutaneous fistula rate of 4% no other complications were observed.

  16. Initial atomic coherences and Ramsey frequency pulling in fountain clocks

    Science.gov (United States)

    Gerginov, Vladislav; Nemitz, Nils; Weyers, Stefan

    2014-09-01

    In the uncertainty budget of primary atomic cesium fountain clocks, evaluations of frequency-pulling shifts of the hyperfine clock transition caused by unintentional excitation of its nearby transitions (Rabi and Ramsey pulling) have been based so far on an approach developed for cesium beam clocks. We re-evaluate this type of frequency pulling in fountain clocks and pay particular attention to the effect of initial coherent atomic states. We find significantly enhanced frequency shifts caused by Ramsey pulling due to sublevel population imbalance and corresponding coherences within the state-selected hyperfine component of the initial atom ground state. Such shifts are experimentally investigated in an atomic fountain clock and quantitative agreement with the predictions of the model is demonstrated.

  17. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Science.gov (United States)

    Thankappan, Krishnakumar; Trivedi, Nirav P.; Sharma, Mohit; Kuriakose, Moni A.; Iyer, Subramania

    2009-01-01

    A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome. PMID:19881028

  18. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Directory of Open Access Journals (Sweden)

    Thankappan Krishnakumar

    2009-01-01

    Full Text Available A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome.

  19. Development of a Wind Turbine Test Rig and Rotor for Trailing Edge Flap Investigation: Static Flap Angles Case

    International Nuclear Information System (INIS)

    Abdelrahman, Ahmed; Johnson, David A

    2014-01-01

    One of the strategies used to improve performance and increase the life-span of wind turbines is active flow control. It involves the modification of the aerodynamic characteristics of a wind turbine blade by means of moveable aerodynamic control surfaces. Trailing edge flaps are relatively small moveable control surfaces placed at the trailing edge of a blade's airfoil that modify the lift of a blade or airfoil section. An instrumented wind turbine test rig and rotor were specifically developed to enable a wide-range of experiments to investigate the potential of trailing edge flaps as an active control technique. A modular blade based on the S833 airfoil was designed to allow accurate instrumentation and customizable settings. The blade is 1.7 meters long, had a constant 178mm chord and a 6° pitch. The modular aerodynamic parts were 3D printed using plastic PC-ABS material. The blade design point was within the range of wind velocities in the available large test facility. The wind facility is a large open jet wind tunnel with a maximum velocity of 11m/s in the test area. The capability of the developed system was demonstrated through an initial study of the effect of stationary trailing edge flaps on blade load and performance. The investigation focused on measuring the changes in flapwise bending moment and power production for different trailing edge flap spanwise locations and deflection angles. The relationship between the load reduction and deflection angle was linear as expected from theory and the highest reduction was caused by the flap furthest from the rotor center. Overall, the experimental setup proved to be effective in measuring small changes in flapwise bending moment within the wind turbine blade and will provide insight when (active) flap control is targeted

  20. 50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 1...

  1. Association of Down's syndrome and testicular cancer.

    Science.gov (United States)

    Dieckmann, K P; Rübe, C; Henke, R P

    1997-05-01

    We present additional clinical evidence for the suspected association of Down's syndrome and testicular germ cell tumors. Four cases of Down's syndrome and testicular cancer are reported. The literature was reviewed for previous cases and analysis regarding common features. The 4 patients were 29 to 35 years old and had clinical stage I seminoma of the testis. Two patients received prophylactic abdominal radiotherapy, 1 is being followed and 1 received adjuvant carboplatin treatment. There was no relapse at followup of 1 to 8 years. One patient also had contralateral cryptorchidism. A total of 16 cases with the association of Down's syndrome and testicular germ cell cancer was documented previously. Evidence for the suspected association of Down's syndrome and testicular cancer is now accumulating. Etiologically it is suspected that, along with genetically determined malformations in many other organs in trisomy 21, the gonads also undergo maldevelopment, thus creating the conditions for step 1 of germ cell tumor oncogenesis in utero. Physicians caring for patients with Down's syndrome should be aware of the possible association with testicular neoplasms.

  2. Medial circumflex femoral artery flap for ischial pressure sore

    Directory of Open Access Journals (Sweden)

    Palanivelu S

    2009-01-01

    Full Text Available A new axial pattern flap based on the terminal branches of the medial circumflex femoral artery is described for coverage of ischial pressure sore. Based on the terminal branches of the transverse branch of medial circumflex femoral artery, which exit through the gap between the quadratus femoris muscle above and the upper border of adductor magnus muscle below, this fascio cutaneous flap is much smaller than the posterior thigh flap but extremely useful to cover ischeal pressure sores. The skin redundancy below the gluteal fold allows a primary closure of the donor defect. It can also be used in combination with biceps femoris muscle flap.

  3. Aerodynamic optimization and mechanism design of flexible variable camber trailing-edge flap

    Directory of Open Access Journals (Sweden)

    Weishuang LU

    2017-06-01

    Full Text Available Trailing-edge flap is traditionally used to improve the takeoff and landing aerodynamic performance of aircraft. In order to improve flight efficiency during takeoff, cruise and landing states, the flexible variable camber trailing-edge flap is introduced, capable of changing its shape smoothly from 50% flap chord to the rear of the flap. Using a numerical simulation method for the case of the GA (W-2 airfoil, the multi-objective optimization of the overlap, gap, deflection angle, and bending angle of the flap under takeoff and landing configurations is studied. The optimization results show that under takeoff configuration, the variable camber trailing-edge flap can increase lift coefficient by about 8% and lift-to-drag ratio by about 7% compared with the traditional flap at a takeoff angle of 8°. Under landing configuration, the flap can improve the lift coefficient at a stall angle of attack about 1.3%. Under cruise state, the flap helps to improve the lift-to-drag ratio over a wide range of lift coefficients, and the maximum increment is about 30%. Finally, a corrugated structure–eccentric beam combination bending mechanism is introduced in this paper to bend the flap by rotating the eccentric beam.

  4. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    Science.gov (United States)

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is

  5. Risk Assessment of Abdominal Wall Thickness Measured on Pre-Operative Computerized Tomography for Incisional Surgical Site Infection after Abdominal Surgery.

    Science.gov (United States)

    Tongyoo, Assanee; Chatthamrak, Putipan; Sriussadaporn, Ekkapak; Limpavitayaporn, Palin; Mingmalairak, Chatchai

    2015-07-01

    The surgical site infection (SSI) is a common complication of abdominal operation. It relates to increased hospital stay, increased healthcare cost, and decreased patient's quality of life. Obesity, usually defined by BMI, is known as one of the risks of SSI. However, the thickness of subcutaneous layers of abdominal wall might be an important local factor affecting the rate of SSI after the abdominal operations. The objective of this study is to assess the importance of the abdominal wall thickness on incisional SSI rate. The subjects of the present study were patients who had undergone major abdominal operations at Thammasat University Hospital between June 2013 and May 2014, and had been investigated with CT scans before their operations. The demographic data and clinical information of these patients were recorded. The thickness ofsubcutaneous fatty tissue from skin down to the most superficial layer of abdominal wall muscle at the surgical site was measured on CT images. The wound infectious complication was reviewed and categorized as superficial and deep incisional SSIfollowing the definition from Centersfor Disease Control and Prevention (CDC) guidelines. The significance ofeach potentialfactors on SSI rates was determined separately with student t-test for quantitative data and χ2-test for categorical data. Then all factors, which had p operative CTscans. Post-operative SSI was 25.2% (35/139), superficial and deep types in 27 and 8 patients, respectively. The comparison of abdominal wall thickness between patients with and without infection was significantly different (20.0 ± 8.4 mm and 16.0 ± 7.2 mm, respectively). When the thickness at 20 mm was used as the cut-off value, 43 of 139 patients had abdominal wall thickness ≥ 20 mm. The incidence of SSI of the thickness ±20 mm group was 37.2% (16/43) and of the less thickness group was 19.8% (19/96), with p operation. However, only abdominal wall thickness and wound classification were still significant

  6. Microstructure and crystallography of Al2O3-Y3Al5O12-ZrO2 ternary eutectic oxide grown by the micropulling down technique

    Science.gov (United States)

    Benamara, Omar; Cherif, Maya; Duffar, Thierry; Lebbou, Kheirreddine

    2015-11-01

    The directional solidification of Al2O3-YAG-ZrO2 eutectic ceramic by a micro-pulling down (μ-PD) technique is investigated. The effect of the pulling rate (0.1-1 mm min-1) on the crystallography and the microstructure is discussed. This ternary eutectic system has a Chinese script microstructure and the eutectic spacing λ depends on the pulling rate υ following the law: λ = 6.5υ-1/2 where λ is in μm and υ in μm/s as derived from the Jackson-Hunt model. With the lower pulling rates, all phases are oriented with the direction parallel to the growth direction; however other orientations appear at the higher pulling rates. The Cr3+ ions R-lines emission in the sapphire phase in the ternary eutectic composite is measured to estimate the stress in the alumina phase which is also shown to depend on the pulling rate.

  7. LASIK flap buttonhole treated immediately by PRK with mitomycin C.

    Science.gov (United States)

    Kymionis, George D; Portaliou, Dimitra M; Karavitaki, Alexandra E; Krasia, Maria S; Kontadakis, Georgios A; Stratos, Aimilianos; Yoo, Sonia H

    2010-03-01

    To describe the visual outcomes of three patients who had LASIK flap buttonhole and were treated immediately with photorefractive keratectomy (PRK) and topical mitomycin C (MMC) 0.02%. Three patients underwent bilateral LASIK with the SCHWIND Carriazo-Pendula 90 microm head microkeratome. In all three cases, a buttonhole flap occurred in the left eye. The flap was repositioned and phototherapeutic keratectomy for 50 microm was used for epithelial removal while immediate PRK with MMC was performed to treat the buttonhole flap. Three months after the procedure, uncorrected distance visual acuity and corrected distance visual acuity were 20/20 with regular topographic findings. Using PRK with MCC immediately after the occurrence of the LASIK flap buttonhole may be an effective treatment.

  8. Long-term Outcomes After Flap Reconstruction in Pediatric Pressure Ulcers.

    Science.gov (United States)

    Firriolo, Joseph M; Ganske, Ingrid M; Pike, Carolyn M; Caillouette, Catherine; Faulkner, Heather R; Upton, Joseph; Labow, Brian I

    2018-02-01

    Pressure ulcers refractory to nonoperative management may undergo flap reconstruction. This study aims to evaluate the long-term outcomes and recurrence rates of flap reconstruction for pediatric pressure ulcers. We reviewed the records of patients who underwent flap reconstruction for pressure ulcer(s) from 1995 to 2013. Twenty-four patients with 30 pressure ulcers, requiring 52 flaps were included. Ulcers were stages III and IV and mostly involved either the ischia (15/30) or sacrum (8/30). Flaps were followed for a median of 4.9 years. Twenty-three patients were wheelchair dependent, and 20 had sensory impairment at their ulcer site(s). Ten patients had a history of noncompliance with preoperative management, 8 of whom experienced ulcer recurrence. Twenty-one ulcers had underlying osteomyelitis, associated with increased admissions (P = 0.019) and cumulative length of stay (P = 0.031). Overall, there was a 42% recurrence rate in ulceration after flap reconstruction. Recurrence was associated with a preoperative history of noncompliance with nonoperative therapy (P = 0.030), but not with flap type or location, age, sex, body mass index, osteomyelitis, or urinary/fecal incontinence (P > 0.05, all). Flap reconstruction can be beneficial in the management of pediatric pressure ulcers. Although high rates of long-term success with this intervention have been reported in children, we found rates of ulcer recurrence similar to that seen in adults. Poor compliance with nonoperative care and failure to modify the biopsychosocial perpetuators of pressure ulcers will likely eventuate in postoperative recurrence. Despite the many comorbidities observed in our patient sample, compliance was the best indicator of long-term skin integrity and flap success.

  9. Effect of topically applied minoxidil on the survival of rat dorsal skin flap.

    Science.gov (United States)

    Gümüş, Nazım; Odemiş, Yusuf; Yılmaz, Sarper; Tuncer, Ersin

    2012-12-01

    Flap necrosis still is a challenging problem in reconstructive surgery that results in irreversible tissue loss. This study evaluated the effect of topically applied minoxidil on angiogenesis and survival of a caudally based dorsal rat skin flap. For this study, 24 male Wistar rats were randomly divided into three groups of eight each. A caudally based dorsal skin flap with the dimensions of 9 × 3 cm was raised. After elevation of the flaps, they were sutured back into their initial positions. In group 1 (control group), 1 ml of isotonic saline was applied topically to the flaps of all the animals for 14 days. In group 2, minoxidil solution was spread uniformly over the flap surface for 7 days after the flap elevation. In group 3, minoxidil solution was applied topically to the flap surface during a 14-day period. On day 7 after the flap elevation, the rats were killed. The average area of flap survival was determined for each rat. Subdermal vascular architecture and angiogenesis were evaluated under a light microscope after two full-thickness skin biopsy specimens had been obtained from the midline of the flaps. The lowest flap survival rate was observed in group 1, and no difference was observed between groups 1 and 2. Compared with groups 1 and 2, group 3 had a significantly increased percentage of flap survival (P minoxidil is vasodilation and that prolonged use before flap elevation leads to angiogenesis, increasing flap viability. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Ipsilateral fasciocutaneous flaps for leg and foot defects

    Directory of Open Access Journals (Sweden)

    Bhattacharya V

    2003-01-01

    Full Text Available It was a revolutionary enhancement for lower limb reconstruction when fasciocutaneous flaps were first described and used in clinical practice in 1981. Subsequently persistent studies were made to emphasize and confirm the rich vascular network associated with deep fascia. Thereafter studies were directed to identify the various types of perforators supplying the deep fascia and the overlying subcutaneous tissue and skin. Accordingly the scientists classified these flaps keeping in mind their clinical applications. The authors of this article have also performed extensive research on various aspects. This has led to better understanding about the finer details of vascularity. Based on this various modifications have been made for safe application of reconstruction for defects extending from knee to sole. To avoid complications the clinician should be able to select the proper procedure as regards the donor site and the possible preoperative and postoperative technical faults. A well-designed and meticulously executed flap usually has smooth recovery. Both Colour Doppler and Audio Doppler are useful tools in planning a safe flap. Now these flaps have proved to be standard technique without requiring a special set up extensive training.

  11. Workload balancing capability of pull systems in MTO production

    NARCIS (Netherlands)

    Germs, R.; Riezebos, J.

    2010-01-01

    Pull systems focusing on throughput time control and applicable in situations with high variety and customisation are scarce. This paper compares three unit-based pull systems that can cope with such situations: POLCA, CONWIP and m-CONWIP. These systems control the shop floor throughput time of

  12. Surgeon-Based 3D Printing for Microvascular Bone Flaps.

    Science.gov (United States)

    Taylor, Erin M; Iorio, Matthew L

    2017-07-01

    Background  Three-dimensional (3D) printing has developed as a revolutionary technology with the capacity to design accurate physical models in preoperative planning. We present our experience in surgeon-based design of 3D models, using home 3D software and printing technology for use as an adjunct in vascularized bone transfer. Methods  Home 3D printing techniques were used in the design and execution of vascularized bone flap transfers to the upper extremity. Open source imaging software was used to convert preoperative computed tomography scans and create 3D models. These were printed in the surgeon's office as 3D models for the planned reconstruction. Vascularized bone flaps were designed intraoperatively based on the 3D printed models. Results  Three-dimensional models were created for intraoperative use in vascularized bone flaps, including (1) medial femoral trochlea (MFT) flap for scaphoid avascular necrosis and nonunion, (2) MFT flap for lunate avascular necrosis and nonunion, (3) medial femoral condyle (MFC) flap for wrist arthrodesis, and (4) free fibula osteocutaneous flap for distal radius septic nonunion. Templates based on the 3D models allowed for the precise and rapid contouring of well-vascularized bone flaps in situ, prior to ligating the donor pedicle. Conclusions  Surgeon-based 3D printing is a feasible, innovative technology that allows for the precise and rapid contouring of models that can be created in various configurations for pre- and intraoperative planning. The technology is easy to use, convenient, and highly economical as compared with traditional send-out manufacturing. Surgeon-based 3D printing is a useful adjunct in vascularized bone transfer. Level of Evidence  Level IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Minilaparotomy with a gasless laparoscopic-assisted procedure by abdominal wall lifting for ileorectal anastomosis in patients with slow transit constipation.

    Science.gov (United States)

    Tomita, Ryouichi; Fujisak, Shigeru

    2009-01-01

    Total colectomy with ileorectal anastomosis (IRA) is the most widely adopted procedure. The aim of this study was to introduce a minimally invasive procedure, i.e., minilaparotomy with laparoscopic-assisted procedure, by abdominal wall lifting for IRA in patients with slow transit constipation (STC). Six STC patients (6 women, aged 40-69 years, mean age 56.3 years) underwent minilaparotomy with gasless laparoscopic-assisted approach by abdominal wall lifting for IRA. The present procedure involved a 7-cm lower abdominal median incision made at the beginning of the operation. 12 mm ports were also placed in the right and left upper abdominal quadrant positions. The upper abdominal wall was lifted by a subcutaneous Kirshner wire. The small wound was pulled upward and/or laterally by retractors (abdominal lifting) and conventional surgical instruments were used through the wound. Occasionally laparoscopic assistance was employed. The terminal ileum with total colon was brought out through the small wound and transected, approximately 5 cm from the ileocecal valve. The colon was also resected at the level of promontrium. Then, IRA was performed in the instruments. The total surgical time was 197.7 +/- 33.9 min and the mean estimated blood loss was 176.8 +/- 42.2 ml. There was no surgical mortality. Post-operative hospitalization was 8.1 +/- 2.1 days. Six months after surgery, they defecated 1.8 +/- 2.1 times daily, have no abdominal distension, pain, and incontinence. The patients also take no laxatives. All subjects were satisfied with this procedure. Minilaparotomy with gasless laparoscopic-assisted IRA by abdominal wall lifting could be a safe and efficient technique in the treatment of STC.

  14. Reconstruction of various perinasal defects using facial artery perforator-based nasolabial island flaps.

    Science.gov (United States)

    Yoon, Tae Ho; Yun, In Sik; Rha, Dong Kyun; Lee, Won Jai

    2013-11-01

    Classical flaps for perinasal defect reconstruction, such as forehead or nasolabial flaps, have some disadvantages involving limitations of the arc of rotation and two stages of surgery. However, a perforator-based flap is more versatile and allows freedom in flap design. We introduced our experience with reconstruction using a facial artery perforator-based propeller flap on the perinasal area. We describe the surgical differences between different defect subtypes. Between December 2005 and August 2013, 10 patients underwent perinasal reconstruction in which a facial artery perforator-based flap was used. We divided the perinasal defects into types A and B, according to location. The operative results, including flap size, arc of rotation, complications, and characteristics of the perforator were evaluated by retrospective chart review and photographic evaluation. Eight patients were male and 2 patients were female. Their mean age was 61 years (range, 35-75 years). The size of the flap ranged from 1 cm×1.5 cm to 3 cm×6 cm. Eight patients healed uneventfully, but 2 patients presented with mild flap congestion. However, these 2 patients healed by conservative management without any additional surgery. All of the flaps survived completely with aesthetically pleasing results. The facial artery perforator-based flap allowed for versatile customized flaps, and the donor site scar was concealed using the natural nasolabial fold.

  15. Identification of Flap Motion Parameters for Vibration Reduction in Helicopter Rotors with Multiple Active Trailing Edge Flaps

    OpenAIRE

    Dalli, Uğbreve;ur; Yüksel, Şcedilefaatdin

    2011-01-01

    An active control method utilizing the multiple trailing edge flap configuration for rotorcraft vibration suppression and blade loads control is presented. A comprehensive model for rotor blade with active trailing edge flaps is used to calculate the vibration characteristics, natural frequencies and mode shapes of any complex composite helicopter rotor blade. A computer program is developed to calculate the system response, rotor blade root forces and moments under aerodynamic forcing condit...

  16. Unit Advancement Flap for Lower Lip Reconstruction.

    Science.gov (United States)

    Ogino, Akihiro; Onishi, Kiyoshi; Okada, Emi; Nakamichi, Miho

    2018-05-01

    Lower lip reconstruction requires consideration of esthetic and functional outcome in selecting a surgical procedure, and reconstruction with local tissue is useful. The authors reconstructed full-thickness defects with a unit advancement flap. Reconstruction was performed using this method in 4 patients with lower lip squamous cell carcinoma in whom tumor resection with preservation of the mouth angle was possible. The lower lip resection width was 30 to 45 mm, accounting for 50% to 68% of the entire width of the lower lip. The flap was prepared by lateral extension from above the mental unit and matched with the potential wrinkle line of the lower lip in order to design a unit morphology surrounded by the anterior margin of the depressor labii inferioris muscle. It was elevated as a full-thickness flap composed of the orbicularis oris muscle, skin, and mucosa of the residual lower lip from the bilateral sides, and advanced to the defect. Flap transfer was adjusted by small triangular resection of the skin on the lateral side of the mental unit. The postoperative scar was inconspicuous in all patients and there was no impairment of the mouth opening-closing or articulation functions. This was a relatively simple surgical procedure. A blood supply of the flap was stable, and continuity of the orbicularis oris muscle was reconstructed by transferred the residual lower lip advancement flap from the bilateral sides. The postoperative mouth opening-closing function was sufficient, and dentures could be placed from an early phase in elderly patients. The postoperative scar was consistent with the lip unit morphology, being esthetically superior. This procedure may be applicable for reconstruction of defects approximately 1/3 to 2/3 the width of the lower lip where the mouth angle is preserved.

  17. Extending the use of the gracilis muscle flap in perineal reconstruction surgery.

    Science.gov (United States)

    Goldie, Stephen J; Almasharqah, Riyadh; Fogg, Quentin A; Anderson, William

    2016-08-01

    Reconstruction of the perineum is required following oncological resections. Plastic surgical techniques can be used to restore the aesthetics and function of the perineum. The gracilis myocutaneous flap provides a substantial skin paddle, with minimal donor site morbidity. The flap is pedicled on a perforator from the medial circumflex femoral artery, giving it limited reach across the perineum. Tunnelling the flap under the adductor longus muscle may free up more of the arterial pedicle, increasing its reach. On three female cadavers, bilateral gracilis flaps were raised in the standard surgical manner, giving six flaps in total. With the flaps pedicled across the perineum, the distance from the tip of each flap was measured to the anterior superior iliac spine (ASIS). The flaps were then tunnelled under the adductor longus muscle. The distances to the ASIS were measured again. The average pedicle length was greater than 7 cm. Tunnelling the flap under the adductor longus muscle increased the reach by more than 4 cm on average. Cadaveric dissection has shown that tunnelling of the flap in a novel way increase its reach across the perineum. This additional flexibility improves its use clinically and is of benefit to plastic surgeons operating in perineal reconstruction. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Free tissue transfer versus pedicled flap reconstruction of head and neck malignancy defects.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    BACKGROUND: With the advent of microsurgery the pedicled flap is considered by many to be an outdated surgical option. AIMS: To explore the relationship between flap survival and pre-morbid risk factors, conduct a comparative analysis of flap and systemic morbidities and complete a cosmesis and functionality assessment for oral and oropharyngeal reconstruction patients. METHODS: 114 patients, over a 13-year period, who had a one-stage reconstructive procedure employing the pectoralis major myocutaneous flap (PMMF) or radial forearm-free flap (RFFF). RESULTS: Variables, including age, smoking and radiation exposure were not statistically significant predictors of flap survival probability. Atelectasis was a significant post-op finding of RFFF patients. Flap dehiscence of >50% was a significant morbidity of PMMF. No statistical difference in cosmetic deformity, diet and socialisation was noted. CONCLUSIONS: Pectoralis major myocutaneous flap remains an enduring and safe flap; however, the RFFF has markedly improved speech performance over the PMMF.

  19. Development of Bird-like Micro Aerial Vehicle with Flapping and Feathering Wing Motions

    Science.gov (United States)

    Maglasang, Jonathan; Goto, Norihiro; Isogai, Koji

    To investigate the feasibility of a highly efficient flapping system capable of avian maneuvers, such as rapid takeoff, hover and gliding, a full scale bird-like (ornithopter) flapping-wing micro aerial vehicle (MAV) shaped and patterned after a typical pigeon (Columba livia) has been designed and constructed. Both numerical and experimental methods have been used in the development of this vehicle. This flapping-wing micro aerial vehicle utilizes both the flapping and feathering motions of an avian wing by employing a novel flapping-feathering mechanism, which has been synthesized and constructed so as to best describe the properly coordinated flapping and feathering wing motions at phase angle difference of 90° in a horizontal steady level flight condition. This design allows high flapping and feathering amplitudes and is configurable for asymmetric wing motions which are desirable in high-speed flapping flight and maneuvering. The preliminary results indicate its viability as a practical and an efficient flapping-wing micro aerial vehicle.

  20. The distally-based island ulnar artery perforator flap for wrist defects

    Directory of Open Access Journals (Sweden)

    Karki Durga

    2007-01-01

    Full Text Available Background: Reconstruction of soft tissue defects around the wrist with exposed tendons, joints, nerves and bone represents a challenge to plastic surgeons, and such defects necessitate flap coverage to preserve hand functions and to protect its vital structures. We evaluated the use of a distally-based island ulnar artery perforator flap in patients with volar soft tissue defects around the wrist. Materials and Methods: Between June 2004 and June 2006, seven patients of soft tissue defects on the volar aspect of the wrist underwent distally-based island ulnar artery perforator flap. Out of seven patients, five were male and two patients were female. This flap was used in the reconstruction of the post road traffic accident defects in four patients and post electric burn defects in three patients. Flap was raised on one or two perforators and was rotated to 180°. Results: All flaps survived completely. Donor sites were closed primarily without donor site morbidity. Conclusion: The distally-based island Ulnar artery perforator flap is convenient, reliable, easy to manage and is a single-stage technique for reconstructing soft tissue defects of the volar aspect of the wrist. Early use of this flap allows preservation of vital structures, decreases morbidity and allows for early rehabilitation.

  1. Rectus muscle flap tear as an independent cause of restricted motility.

    Science.gov (United States)

    Raab, Edward L; Ackert, Jessica M; Ostrovsky, Ann

    2012-08-01

    Most published cases of rectus muscle flap tear have been associated with orbital trauma of various degrees of severity. When they accompany an orbital fracture, however, it is difficult to determine whether the flap tear is merely an incidental additional finding or a major contributing cause of the resulting restriction. How to treat the flap itself remains an open question. We report a 24-year-old man with an inferior rectus muscle flap tear caused by direct laceration of the muscle. The major finding was a "reverse leash" vertical restriction. Discarding the flap instead of reattaching it did not prevent a successful result. Our case supports the proposition that rectus muscle flap tear can be a restriction-producing entity. Copyright © 2012 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  2. Experimental Investigations on the Pull-Out Behavior of Tire Strips Reinforced Sands.

    Science.gov (United States)

    Li, Li-Hua; Chen, Yan-Jun; Ferreira, Pedro Miguel Vaz; Liu, Yong; Xiao, Heng-Lin

    2017-06-27

    Waste tires have excellent mechanical performance and have been used as reinforcing material in geotechnical engineering; however, their interface properties are poorly understood. To further our knowledge, this paper examines the pull-out characteristics of waste tire strips in a compacted sand, together with uniaxial and biaxial geogrids also tested under the same conditions. The analysis of the results shows that the interlocking effect and pull-out resistance between the tire strip and the sand is very strong and significantly higher than that of the geogrids. In the early stages of the pull-out test, the resistance is mainly provided by the front portion of the embedded tire strips, as the pull-out test continues, more and more of the areas towards the end of the tire strips are mobilized, showing a progressive failure mechanism. The deformations are proportional to the frictional resistance between the tire-sand interface, and increase as the normal stresses increase. Tire strips of different wear intensities were tested and presented different pull-out resistances; however, the pull-out resistance mobilization patterns were generally similar. The pull-out resistance values obtained show that rubber reinforcement can provide much higher pull-out forces than the geogrid reinforcements tested here, showing that waste tires are an excellent alternative as a reinforcing system, regardless of the environmental advantages.

  3. Free-flap surgical correction of facial deformity after anteromedial maxillectomy.

    Science.gov (United States)

    Sarukawa, Shunji; Kamochi, Hideaki; Noguchi, Tadahide; Sunaga, Ataru; Uda, Hirokazu; Mori, Yoshiyuki; Nishino, Hiroshi; Yoshimura, Kotaro

    2017-09-01

    Anteromedial maxillectomy is typically performed in conjunction with low-dose radiotherapy and intraarterial chemotherapy. In doing so, the extent of surgical defects is reduced. However, nasal deviation and oral incompetence may ensue, due to cicatricial contracture of wounds, and may be distressing to these patients. Herein, we report a series of eight free perforator flap procedures (anterolateral thigh [ALT] flap, 6; thoracodorsal artery perforator [TAP] flap, 2) used to correct such deformities. The TAP flap was combined with scapular tip [ST] osseous flap in patients with added zygomatic prominence defects. Three adipocutaneous parts developed from each perforator flap were applied as follows: two to reconstruct nasal lining and oral vestibule, and one to augment cheek volume. All aesthetic results proved satisfactory, although orbital dystopia and contracture of mimic muscles were not resolved completely. These secondary interventions are suitable for sequelae of simple anteromedial maxillectomy. Immediate reconstruction should be considered if orbital floor and mimic muscles are involved. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Internal-external flow integration for a thin ejector-flapped wing section

    Science.gov (United States)

    Woolard, H. W.

    1979-01-01

    Thin airfoil theories of an ejector flapped wing section are reviewed. The global matching of the external airfoil flow with the ejector internal flow and the overall ejector flapped wing section aerodynamic performance are examined. Mathematical models of the external and internal flows are presented. The delineation of the suction flow coefficient characteristics are discussed. The idealized lift performance of an ejector flapped wing relative to a jet augmented flapped wing are compared.

  6. Reverse Saphenous Conduit Flap in 19 Dogs and 1 Cat.

    Science.gov (United States)

    Cavalcanti, Jacqueline V J; Barry, Sabrina L; Lanz, Otto I; Barnes, Katherine; Coutin, Julia V

    2018-05-14

    The purpose of this retrospective study was to report the outcomes of 19 dogs and 1 cat undergoing reverse saphenous conduit flap between 1999 and 2016. Reverse saphenous conduit flap was used to treat traumatic wounds and wounds resulting from tumor excision in the hind limb; the majority of cases had medial shearing injuries. All animals had complete flap survival. In five animals (20%), minor donor site dehiscence occurred, which did not require surgery. Other postoperative complications included signs of severe venous congestion in one dog. Reverse saphenous conduit flap is a useful technique to repair skin defects of the distal hind limb.

  7. Chronic abdominal wall pain misdiagnosed as functional abdominal pain.

    Science.gov (United States)

    van Assen, Tijmen; de Jager-Kievit, Jenneke W A J; Scheltinga, Marc R; Roumen, Rudi M H

    2013-01-01

    The abdominal wall is often neglected as a cause of chronic abdominal pain. The aim of this study was to identify chronic abdominal wall pain syndromes, such as anterior cutaneous nerve entrapment syndrome (ACNES), in a patient population diagnosed with functional abdominal pain, including irritable bowel syndrome, using a validated 18-item questionnaire as an identification tool. In this cross-sectional analysis, 4 Dutch primary care practices employing physicians who were unaware of the existence of ACNES were selected. A total of 535 patients ≥18 years old who were registered with a functional abdominal pain diagnosis were approached when they were symptomatic to complete the questionnaire (maximum 18 points). Responders who scored at least the 10-point cutoff value (sensitivity, 0.94; specificity, 0.92) underwent a diagnostic evaluation to establish their final diagnosis. The main outcome was the presence and prevalence of ACNES in a group of symptomatic patients diagnosed with functional abdominal pain. Of 535 patients, 304 (57%) responded; 167 subjects (31%) recently reporting symptoms completed the questionnaire. Of 23 patients who scored above the 10-point cutoff value, 18 were available for a diagnostic evaluation. In half of these subjects (n = 9) functional abdominal pain (including IBS) was confirmed. However, the other 9 patients were suffering from abdominal wall pain syndrome, 6 of whom were diagnosed with ACNES (3.6% prevalence rate of symptomatic subjects; 95% confidence interval, 1.7-7.6), whereas the remaining 3 harbored a painful lipoma, an abdominal herniation, and a painful scar. A clinically relevant portion of patients previously diagnosed with functional abdominal pain syndrome in a primary care environment suffers from an abdominal wall pain syndrome such as ACNES.

  8. Efficiency of Lift Production in Flapping and Gliding Flight of Swifts

    Science.gov (United States)

    Henningsson, Per; Hedenström, Anders; Bomphrey, Richard J.

    2014-01-01

    Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord) and/or twist from root to tip (reducing local angle of attack). We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag. PMID:24587260

  9. Efficiency of lift production in flapping and gliding flight of swifts.

    Directory of Open Access Journals (Sweden)

    Per Henningsson

    Full Text Available Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord and/or twist from root to tip (reducing local angle of attack. We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag.

  10. Blood flow autoregulation in pedicled flaps

    DEFF Research Database (Denmark)

    Bonde, Christian T; Holstein-Rathlou, Niels-Henrik; Elberg, Jens J

    2009-01-01

    was to evaluate if, and to what extent, a tissue flap could compensate a reduction in blood flow due to an acute constriction of the feed artery. Further, we wanted to examine the possible role of smooth muscle L-type calcium channels in the autoregulatory mechanism by pharmacological intervention with the L......, the flow in the pedicle was reduced and the flow was recorded. RESULTS: The flaps showed a strong autoregulatory response with complete compensation for flow reductions of up to 70-80%. Infusion of nimodipine caused a 28+/-10% increase in blood flow and removed the autoregulation. Papaverine caused...... a further increase in blood flow by 61+/-19%. The time control experiments proved that the experimental procedure was reproducible and stable over time. CONCLUSIONS: A tissue flap can nearly completely compensate for repeated flow reductions of up to 70-80%. This is due to a decrease in the peripheral...

  11. Scapula kinematics of pull-up techniques: Avoiding impingement risk with training changes.

    Science.gov (United States)

    Prinold, Joe A I; Bull, Anthony M J

    2016-08-01

    Overhead athletic activities and scapula dyskinesia are linked with shoulder pathology; pull-ups are a common training method for some overhead sports. Different pull-up techniques exist: anecdotally some are easier to perform, and others linked to greater incidences of pathology. This study aims to quantify scapular kinematics and external forces for three pull-up techniques, thus discussing potential injury implications. An observational study was performed with eleven participants (age=26.8±2.4 years) who regularly perform pull-ups. The upward motions of three pull-up techniques were analysed: palms facing anterior, palms facing posterior and wide-grip. A skin-fixed scapula tracking technique with attached retro-reflective markers was used. High intra-participant repeatability was observed: mean coefficients of multiple correlations of 0.87-1.00 in humerothoracic rotations and 0.77-0.90 for scapulothoracic rotations. Standard deviations of hand force was low: kinematics were observed between the pull-up techniques. The reverse technique has extreme glenohumeral internal-external rotation and large deviation from the scapula plane. The wide technique has a reduced range of pro/retraction in the same HT plane of elevation and 90° of arm abduction with 45° external rotation was observed. All these factors suggest increased sub-acromial impingement risk. The scapula tracking technique showed high repeatability. High arm elevation during pull-ups reduces sub-acromial space and increases pressure, increasing the risk of impingement injury. Wide and reverse pull-ups demonstrate kinematics patterns linked with increased impingement risk. Weight-assisted front pull-ups require further investigation and could be recommended for weaker participants. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  12. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Jessica K.; Vinson, Emily N. [Duke University Hospital, Department of Radiology, Durham, NC (United States); Taylor, Dean C. [Duke University Hospital, Department of Orthopaedic Surgery, Durham, NC (United States)

    2017-08-15

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  13. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    International Nuclear Information System (INIS)

    Stewart, Jessica K.; Vinson, Emily N.; Taylor, Dean C.

    2017-01-01

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  14. "Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.

    Science.gov (United States)

    Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng

    2008-12-01

    Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.

  15. Combination of Nasolabial V-Y Advancement Flap and Glabellar Subcutaneous Pedicled Flap for Reconstruction of Medial Canthal Defect

    Directory of Open Access Journals (Sweden)

    Hiromichi Matsuda

    2014-02-01

    Full Text Available A 77-year-old woman presented with a 1-year history of a right medial canthal tumor, which was histopathologically diagnosed as a basal cell carcinoma. After removal of the tumor with a 4-mm safety margin, the defect occupied the areas superior and inferior to the medial canthal tendon. We first reconstructed the lower part of the defect using a nasolabial V-Y advancement flap to make an elliptic defect in the upper part. We then created a glabellar subcutaneous pedicled flap to match the residual upper elliptic defect with the major axis set along a relaxed skin tension line. The pedicled glabellar flap was passed through a subcutaneous tunnel to the upper residual defect. At 6 months postoperatively, the patient showed no tumor recurrence and a good cosmetic outcome.

  16. Flapping wing flight can save aerodynamic power compared to steady flight.

    Science.gov (United States)

    Pesavento, Umberto; Wang, Z Jane

    2009-09-11

    Flapping flight is more maneuverable than steady flight. It is debated whether this advantage is necessarily accompanied by a trade-off in the flight efficiency. Here we ask if any flapping motion exists that is aerodynamically more efficient than the optimal steady motion. We solve the Navier-Stokes equation governing the fluid dynamics around a 2D flapping wing, and determine the minimal aerodynamic power needed to support a specified weight. While most flapping wing motions are more costly than the optimal steady wing motion, we find that optimized flapping wing motions can save up to 27% of the aerodynamic power required by the optimal steady flight. We explain the cause of this energetic advantage.

  17. Reconstruction of Nasal Skin Cancer Defects with Local Flaps

    Directory of Open Access Journals (Sweden)

    A. C. Salgarelli

    2011-01-01

    Full Text Available Reconstruction of nasal defects must preserve the integrity of complex facial functions and expressions, as well as facial symmetry and a pleasing aesthetic outcome. The reconstructive modality of choice will depend largely on the location, size, and depth of the surgical defect. Individualized therapy is the best course, and numerous flaps have been designed to provide coverage of a variety of nasal-specific defects. We describe our experience in the aesthetic reconstruction of nasal skin defects following oncological surgery. The use of different local flaps for nasal skin cancer defects is reported in 286 patients. Complications in this series were one partial flap dehiscence that healed by secondary intention, two forehead flaps, and one bilobed flap with minimal rim necrosis that resulted in an irregular scar requiring revision. Aesthetic results were deemed satisfactory by all patients and the operating surgeons. The color and texture matches were aesthetically good, and the nasal contour was distinct in all patients. All scars were inconspicuous and symmetrical. No patient had tenting or a flat nose.

  18. Reconstruction of Nasal Skin Cancer Defects with Local Flaps

    International Nuclear Information System (INIS)

    Salgarelli, A. C.; Bellini, P.; Multinu, A.; Consolo, U.; Magnoni, C.; Francomano, M.; Fantini, F.; Seidenari, S.

    2011-01-01

    Reconstruction of nasal defects must preserve the integrity of complex facial functions and expressions, as well as facial symmetry and a pleasing aesthetic outcome. The reconstructive modality of choice will depend largely on the location, size, and depth of the surgical defect. Individualized therapy is the best course, and numerous flaps have been designed to provide coverage of a variety of nasal-specific defects. We describe our experience in the aesthetic reconstruction of nasal skin defects following oncological surgery. The use of different local flaps for nasal skin cancer defects is reported in 286 patients. Complications in this series were one partial flap dehiscence that healed by secondary intention, two forehead flaps, and one bilobed flap with minimal rim necrosis that resulted in an irregular scar requiring revision. Aesthetic results were deemed satisfactory by all patients and the operating surgeons. The color and texture matches were aesthetically good, and the nasal contour was distinct in all patients. All scars were inconspicuous and symmetrical. No patient had tenting or a flat nose.

  19. Parametric study of fluid flow manipulation with piezoelectric macrofiber composite flaps

    Science.gov (United States)

    Sadeghi, O.; Tarazaga, P.; Stremler, M.; Shahab, S.

    2017-04-01

    Active Fluid Flow Control (AFFC) has received great research attention due to its significant potential in engineering applications. It is known that drag reduction, turbulence management, flow separation delay and noise suppression through active control can result in significantly increased efficiency of future commercial transport vehicles and gas turbine engines. In microfluidics systems, AFFC has mainly been used to manipulate fluid passing through the microfluidic device. We put forward a conceptual approach for fluid flow manipulation by coupling multiple vibrating structures through flow interactions in an otherwise quiescent fluid. Previous investigations of piezoelectric flaps interacting with a fluid have focused on a single flap. In this work, arrays of closely-spaced, free-standing piezoelectric flaps are attached perpendicular to the bottom surface of a tank. The coupling of vibrating flaps due to their interacting with the surrounding fluid is investigated in air (for calibration) and under water. Actuated flaps are driven with a harmonic input voltage, which results in bending vibration of the flaps that can work with or against the flow-induced bending. The size and spatial distribution of the attached flaps, and the phase and frequency of the input actuation voltage are the key parameters to be investigated in this work. Our analysis will characterize the electrohydroelastic dynamics of active, interacting flaps and the fluid motion induced by the system.

  20. VACUUM THERAPY VERSUS ABDOMINAL EXERCISES ON ABDOMINAL OBESITY

    Directory of Open Access Journals (Sweden)

    Nevein Mohammed Mohammed Gharib

    2016-06-01

    Full Text Available Background: Obesity is a medical condition that may adversely affect wellbeing and leading to increased incidence of many health problems. Abdominal obesity tends to be associated with weight gain and obesity and it is significantly connected with different disorders like coronary heart disease and type II diabetes mellitus.This study was conducted to investigate the efficacy of vacuum therapy as compared to abdominal exercises on abdominal obesity in overweight and obese women. Methods: Thirtyoverweight and obese women participated in this study with body mass index > 25 kg/m2andwaist circumference ≥ 85 cm. Their ages ranged from 28 - 40 years old.The subjects were excluded if they have diabetes, abdominal infection diseases or any physical limitation restricting exercise ability. They were randomly allocated into two equal groups; group I and group II. Group I received vacuum therapy sessions (by the use of LPG device in addition to aerobic exercise training. Group II received abdominal exercises in addition to the same aerobic exercisesgiven to group I. This study was extended for successive 8 weeks (3 sessions/ week. All subjects were assessed for thickness ofnthe abdominal skin fold, waist circumference and body mass index. Results: The results of this study showeda significant difference between group I and group II post-interventionas regarding to the mean values of waist circumference and abdominal skin fold thickness (p<0.05. Conclusion: It can be concluded that aerobic exercises combined with vacuum therapy (for three sessions/week for successive 8 weeks have a positive effect on women with abdominal obesity in terms of reducing waist circumference and abdominal skin fold thickness.

  1. Palatoplasty: suturing the mucoperiosteal flaps to the hard palate through hole.

    Science.gov (United States)

    Hwang, Kun; Lee, Ji Hun; Kim, Yu Jin; Le, Se Il

    2009-05-01

    We satisfactorily repaired a wide cleft palate using a method of V-Y pushback and anchoring the oral mucoperiosteal flap onto the bony ridge of the cleft. An 8-year-old Vietnamese girl had a wide incomplete bilateral posterior cleft palate associated with congenital cardiac malformations. The gap of the posterior cleft was 2.5 cm, which exceeded the total widths of the palatal shelves. We applied V-Y pushback and used a vomer flap to close the wide cleft palate. The posterior two thirds of the nasal mucosae from the cleft margins were sutured to the vomer flap. The nasal side of the anterior one third of the bony cleft was uncovered. The elevated bilateral mucoperiosteal flaps were brought together to the midline and sutured to the anterior triangular flap in a V-Y pushback fashion. Four holes were drilled 5 mm lateral to each bony cleft margin. The lateral sides of the mucoperiosteal flaps were fixed to the palate bone with 3-0 Vicryl through the hole. This method reduces the tension of the flap which might frequently cause oronasal fistula and also improve viability.

  2. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  3. Experimental and numerical study of an autonomous flap

    NARCIS (Netherlands)

    Bernhammer, L.O.; Navalkar, S.T.; Sodja, J.; De Breuker, R.; Karpel, M.

    2015-01-01

    This paper presents the experimental and numerical study of an autonomous load alleviation concept using trailing edge flaps. The flaps are autonomous units, which for instance can be used for gust load alleviation. The unit is self-powered and self-actuated through trailing edge tabs which are

  4. A simple concept for covering pressure sores: wound edge-based propeller perforator flap.

    Science.gov (United States)

    Kelahmetoglu, Osman; Van Landuyt, Koenraad; Yagmur, Caglayan; Sommeling, Casper E; Keles, Musa K; Tayfur, Volkan; Simsek, Tekin; Demirtas, Yener; Guneren, Ethem

    2017-12-01

    We present a new surgical modification to allow propeller perforator flaps to cover pressure sores at various locations. We used a propeller perforator flap concept based on the detection of newly formed perforator vessels located 1 cm from the wound margin and stimulated by the chronic inflammation process. Between January 2009 and January 2017, 33 wound edge-based propeller perforator flaps were used to cover pressure sores at various locations in 28 patients. In four cases more than one flap was used on the same patient. The patients comprised 18 males and 10 females with a mean age of 41·25 (range, 16-70) years. All patients underwent follow-up for 0-12 months. The mean follow-up duration was 5·03 months. Venous congestion was observed in three flaps that were rotated by 180° (9·1%). However, there was a significant difference between flaps rotated by 90° and 180° according to the complication rate (P = 0·034). Out of 33 flaps, 29 flaps healed uneventfully. Patients were able to sit and lie on their flaps three weeks after surgery. In our study, we were able to obtain satisfying final results using these novel flaps. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Variability of extreme flap loads during turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Ronold, K O [Det Norske Veritas, Hoevik (Norway); Larsen, G C [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1999-03-01

    The variability of extreme flap loads is of utmost importance for design of wind-turbine rotor blades. The flap loads of interest consist of the flap-wise bendin moment response at the blade root whose variability in the short-term, for a given wind climate, can be represented by a stationary process. A model for the short-term bending moment process is presented, and the distribution of its associated maxima is derived. A model for the wind climate is given in terms of the probability distributions for the 10-minute mean wind speed and the standard deviation of the arbitrary wind speed. This is used to establish the distribution of the largest flap-wise bending moment in a specific reference period, and it is outlined how a characteristic bending moment for use in design can be extracted from this distribution. The application of the presented distribution models is demonstrated by a numerical example for a site-specific wind turbine. (au)

  6. Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2 and two different femtosecond lasers (FS60 and FS200

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2013-04-01

    Full Text Available A John Kanellopoulos,1,2 George Asimellis1 1Laservision.gr Institute, Athens, Greece; 2NYU Medical School, New York, USA Purpose: To evaluate programmed versus achieved laser-assisted in situ keratomileusis (LASIK flap central thickness and investigate topographic flap thickness variability, as well as the effect of potential epithelial remodeling interference on flap thickness variability. Patients and methods: Flap thickness was investigated in 110 eyes that had had bilateral myopic LASIK several years ago (average 4.5 ± 2.7 years; range 2–7 years. Three age-matched study groups were formed, based on the method of primary flap creation: Group A (flaps made by the Moria Surgical M2 microkeratome [Antony, France], Group B (flaps made by the Abbott Medical Optics IntraLase™ FS60 femtosecond laser [Santa Ana, CA, USA], and Group C (flaps made by the Alcon WaveLight® FS200 femtosecond laser [Fort Worth, TX, USA]. Whole-cornea topographic maps of flap and epithelial thickness were obtained by scanning high-frequency ultrasound biomicroscopy. On each eye, topographic flap and epithelial thickness variability was computed by the standard deviation of thickness corresponding to 21 equally spaced points over the entire corneal area imaged. Results: The average central flap thickness for each group was 138.33 ± 12.38 µm (mean ± standard deviation in Group A, 128.46 ± 5.72 µm in Group B, and 122.00 ± 5.64 µm in Group C. Topographic flap thickness variability was 9.73 ± 4.93 µm for Group A, 8.48 ± 4.23 µm for Group B, and 4.84 ± 1.88 µm for Group C. The smaller topographic flap thickness variability of Group C (FS200 was statistically significant compared with that of Group A (M2 (P = 0.004, indicating improved topographic flap thickness consistency – that is, improved precision – over the entire flap area affected. Conclusions: The two femtosecond lasers produced a smaller flap thickness and reduced variability than the mechanical

  7. Structural and mechanism design of an active trailing-edge flap blade

    DEFF Research Database (Denmark)

    Lee, Jae Hwan; Natarajan, Balakumaran; Eun, Won Jong

    2013-01-01

    , as the blade is able to withstand increased centrifugal force. The cross-section of the active blade is designed first. A stress/strain recovery analysis is then conducted to verify its structural integrity. A one-dimensional beam analysis is also carried out to assist with the construction of the fan diagram...... of the rotor through modification of unsteady aerodynamic loads. Piezoelectric actuators installed inside the blade manipulate the motion of the trailing edge flap. The proposed blade rotates at higher speed and additional structures are included to support the actuators and the flap. This improves the design....... To select the actuator and design the flap actuation region, the flap hinge moment is estimated via a CFD analysis. To obtain the desired flap deflection of ±4°, three actuators are required. The design of the flap actuation region is validated using a test bed with a skin hinge. However, because the skin...

  8. Method to measure the force to pull and to break pin bones of fish.

    Science.gov (United States)

    Balaban, Murat O; Jie, Hubert; Yin Yee, Yin; Alçiçek, Zayde

    2015-02-01

    A texture measurement device was modified to measure the force required to pull pin bones from King salmon (Oncorhynchus tshawytscha), snapper (Pagrus auratus), and kahawai (Arripis trutta). Pulled bones were also subjected to tension to measure the breaking force. For all fish, the pulling force depended on the size of the fish, and on the length of the pin bone (P bones. For example, fresh small salmon (about 1500 g whole) required 600 g on average to pull pin bones, and large fish (about 3700 g whole) required 850 g. Longer bones required greater pulling force. The breaking force followed the same trend. In general, the breaking force was greater than the pulling force. This allows the removal of the bones without breaking them. There was no statistically significant (P > 0.05) difference between the forces (both pulling and breaking) from fresh and frozen/thawed samples, although in general frozen/thawed samples required less force to pull. With the quantification of pulling and breaking forces for pin bones, it is possible to design and build better, "more intelligent" pin bone removal equipment. © 2015 Institute of Food Technologists®

  9. Nasoseptal flap for palatal reconstruction after hemi-maxillectomy: case report.

    Science.gov (United States)

    Alwashahi, M K; Battaglia, P; Turri-Zanoni, M; Castelnuovo, P

    2018-01-01

    Palatal reconstruction following maxillectomy is a surgical challenge, and a nasoseptal flap is a feasible approach. This paper reports the first known successful clinical case of a nasoseptal pedicle flap applied for the reconstruction of maxillary bone following hemi-maxillectomy. This report describes hemi-maxillectomy in a 60-year-old Italian male diagnosed with stage IV squamous cell carcinoma of the left maxilla. Endoscopic transnasal extended medial maxillectomy was performed, followed by a transoral modified midfacial degloving technique for removal of the maxillary bone. The contralateral nasoseptal pedicle flap was used to reconstruct the defect. The case was followed up prospectively for the assessment of flap reception and healing. The locally accessible nasoseptal flap is a viable alternative for palatal reconstruction; therefore, a second surgical procedure with its associated donor site morbidity can be avoided. Large-scale studies may help in establishing the cosmetic and functional outcomes.

  10. Frobenius Pull Backs of Vector Bundles in Higher Dimensions

    Indian Academy of Sciences (India)

    We prove that for a smooth projective variety of arbitrary dimension and for a vector bundle over , the Harder–Narasimhan filtration of a Frobenius pull back of is a refinement of the Frobenius pull back of the Harder–Narasimhan filtration of , provided there is a lower bound on the characteristic (in terms of rank of ...

  11. The Anconeus Muscle Free Flap: Clinical Application to Lesions on the Hand

    Directory of Open Access Journals (Sweden)

    Byung-Joon Jeon

    2017-09-01

    Full Text Available Background It can be difficult to select an appropriate flap for various defects on the hand. Although defects of the hand usually must be covered with a skin flap, some defects require a flap with rich blood supply and adequate additive soft tissue volume. The authors present their experience with the anconeus muscle free flap in the reconstruction of various defects and the release of scar contractures of the hand. Methods Ten patients underwent reconstruction of the finger or release of the first web space using the anconeus muscle free flap from May 1998 to October 2013. Adequate bed preparations with thorough debridement or contracture release were performed. The entire anconeus muscle, located at the elbow superficially, was harvested, with the posterior recurrent interosseous artery as a pedicle. The defects were covered with a uniformly trimmed anconeus muscle free flap. Additional debulking of the flap and skin coverage using a split-thickness skin graft were performed 3 weeks after the first operation. Results The average flap size was 18.7 cm2 (range, 13.5–30 cm2. All flaps survived without significant complications. Vein grafts for overcoming a short pedicle were necessary in 4 cases. Conclusions The anconeus muscle free flap can be considered a reliable reconstructive option for small defects on the hand or contracture release of the web space, because it has relatively consistent anatomy, provides robust blood supply within the same operative field, and leads to no functional loss at the donor site.

  12. A comparison of surgical outcome of fasciocutaneous V–Y advancement flap and Limberg transposition flap for recurrent sacrococcygeal pilonidal sinus disease

    Directory of Open Access Journals (Sweden)

    Bahadır Öz

    2017-05-01

    Conclusion: Limberg transposition flap may be use in recurrent cases of PSD, because of the lower recurrence rate and less hospital stay time, early return to work. Most important advantage of fasciocutaneous V–Y advancement flap is the ability to close larger defects in recurrent cases.

  13. Primary Observations on the Influence of 60Co Local Irradiation on Free Skin Flaps

    Institute of Scientific and Technical Information of China (English)

    杨建荣; 张园

    2002-01-01

    Objective To study the effect of postoperative radiation on free skin flaps.Methods Twenty-nine patients with free skin flaps applied to the plerosis of the postoperative defectwere followed up. Twenty-eight out of 29 patients received forearm free flaps while 1 had anterolater-al femoris skin flaps in a size ranging from 14 cm× 6 cm to 8 cm× 4 cm. These flaps were exposedto 60Co radiation ranging 40-69 Gy. Results Observation during irradiation: no visible changes ofskin flaps and oral mucous membrane were detected when irradiation dose was within 40 Gy; somechanges may be detected over 40 Gy. Observation 1 - 4 months after irradiation: pigmentations werefound in areas of erosion epidermis; skin flaps got dark but without evidence of necrosis. Observation2 years after irradiation: no necrosis happened in 29 skin flaps. Hairs were found on 15 of 29flaps. Sensation occurred within the margin of 1 cm. Conclusion Free skin flap can endure irradi-ation at the dose of 60 Gy.

  14. Seromuscular Colonic Flap for Intrapelvic Soft-Tissue Coverage: A Reconstructive Option for Plastic Surgeons When Traditionally Used Flaps Are Not Available

    Directory of Open Access Journals (Sweden)

    Johnathon Aho

    2015-01-01

    Full Text Available Background. Reconstruction of intrapelvic defects can be a challenging problem in patients with limited regional muscle flap options and previously resected omentum. In such situations, alternative methods of mobilizing vascularized tissue may be required. Methods. A case of a patient that underwent pelvic extirpation for recurrent rectal cancer who had limited donor sites for flap reconstruction is presented. The mucosa was removed from a blind loop of colon, and a pedicled seromuscular flap based on the colonic mesentery was placed into the pelvis for vascularized soft-tissue coverage and elimination of dead space. Results. The postoperative course was only complicated by a small subcutaneous fluid collection beneath the sacrectomy skin incision, which was drained with radiological assistance. The patient recovered without any major postoperative complications. Conclusion. Seromuscular colonic flap is a useful option for soft-tissue coverage after pelvic extirpation and should be considered by plastic surgeons when other reconstruction options are not available.

  15. Yarn Pull-Out as a Mechanism for Dissipation of Ballistic Impact Energy in Kevlar KM-2 Fabric, Part 1: Quasi-Static Characterization of Yarn Pull-Out

    National Research Council Canada - National Science Library

    Kirkwood, Keith

    2004-01-01

    .... This study reports the effects of fabric length, number of yarns pulled, arrangement of yarns, and transverse tension on the force-displacement curves for yarn pull-out tests on Kevlar KM-2 fabric...

  16. Stress reactivity in childhood functional abdominal pain or irritable bowel syndrome.

    Science.gov (United States)

    Gulewitsch, M D; Weimer, K; Enck, P; Schwille-Kiuntke, J; Hautzinger, M; Schlarb, A A

    2017-01-01

    Frequent abdominal pain (AP) in childhood has been shown to be associated with elevated experience of stress and with deficits in stress coping, but psychophysiological stress reactivity has been studied rarely. We examined whether children with frequent AP show altered reactions of the parasympathetic nervous system and the hypothalamic-pituitary-adrenal (HPA) axis during and following an afternoon laboratory social stress task in comparison to healthy children and children with anxiety disorders. Twenty-four children with frequent AP (18 with functional AP and six with irritable bowel syndrome; M = 9.9 years), and 24 healthy controls underwent stressful free speech and arithmetic tasks. Twelve children with anxiety disorders served as second comparison sample. Groups were compared regarding parasympathetic reaction and saliva cortisol concentration. We found no differences in parasympathetic withdrawal between the groups. Concerning the HPA axis, we detected an attenuated cortisol reactivity in children with AP compared to both other groups. This study provides preliminary evidence that childhood AP is not associated with altered parasympathetic withdrawal during stress. It seems to be related to a down-regulated reactivity of the HPA axis. This pattern was ascertained in comparison to healthy children and also in comparison to children with anxiety disorders. Childhood abdominal pain could be related to down-regulated HPA axis reactivity to stress but not to altered parasympathetic reaction. Children with abdominal pain and children with anxiety disorders exhibit a divergent stress-related HPA axis reaction. © 2016 European Pain Federation - EFIC®.

  17. Optical pulling force and conveyor belt effect in resonator-waveguide system.

    Science.gov (United States)

    Intaraprasonk, Varat; Fan, Shanhui

    2013-09-01

    We present the theoretical condition and actual numerical design that achieves an optical pulling force in resonator-waveguide systems, where the direction of the force on the resonator is in the opposite direction to the input light in the waveguide. We also show that this pulling force can occur in conjunction with the lateral optical equilibrium effect, such that the resonator is maintained at the fixed distance from the waveguide while experiencing the pulling force.

  18. Microvascular free flaps in the management of war wounds with tissue defects

    Directory of Open Access Journals (Sweden)

    Kozarski Jefta

    2003-01-01

    Full Text Available Background. War wounds caused by modern infantry weapons or explosive devices are very often associated with the defects of soft and bone tissue. According to their structure, tissue defects can be simple or complex. In accordance with war surgical doctrine, at the Clinic for Plastic Surgery and Burns of the Military Medical Academy, free flaps were used in the treatment of 108 patients with large tissue defects. With the aim of closing war wounds, covering deep structures, or making the preconditions for reconstruction of deep structures, free flaps were applied in primary, delayed, or secondary term. The main criteria for using free flaps were general condition of the wounded, extent, location, and structure of tissue defects. The aim was also to point out the advantages and disadvantages of the application of free flaps in the treatment of war wounds. Methods. One hundred and eleven microvascular free flaps were applied, both simple and complex, for closing the war wounds with extensive tissue defects. The main criteria for the application of free flaps were: general condition of the wounded, size, localization, and structure of tissue defects. For the extensive defects of the tissue, as well as for severely contaminated wounds latissimus dorsi free flaps were used. For tissue defects of distal parts of the lower extremities, scapular free flaps were preferred. While using free tissue transfer for recompensation of bone defects, free vascularized fibular grafts were applied, and in skin and bone defects complex free osteoseptocutaneous fibular, free osteoseptocutaneous radial forearm, and free skin-bone scapular flaps were used. Results. After free flap transfer 16 (14,4% revisions were performed, and after 8 unsuccessful revisions another free flaps were utilized in 3 (37,5% patients, and cross leg flaps in 5 (62,5% patients. Conclusion. The treatment of war wounds with large tissue defects by the application of free microvascular flaps

  19. Structural and mechanism design of an active trailing-edge flap blade

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hwan [Samsung Techwin R and D Center, Seongnam (Korea, Republic of); Natarajan, Balakumaran; Eun, Won Jong; Shin, Sang Joon [Seoul National University, Seoul (Korea, Republic of); R, Viswamurthy S. [National Aerospace Laboratories, Bangalore (India); Park, Jae Sang [Agency for Defense Development, Daejeon (Korea, Republic of); Kim, Tae Song [Technical University of Denmark, Risoe Campus, Roskilde (Denmark)

    2013-09-15

    A conventional rotor control system restricted at 1/rev frequency component is unable to vary the hub vibratory loads and the aero acoustic noise, which exist in high frequency components. Various active rotor control methodologies have been examined in the literature to alleviate the problem of excessive hub vibratory loads and noise. The active control device manipulates the blade pitch angle with arbitrary higher harmonic frequencies individually. In this paper, an active trailing-edge flap blade, which is one of the active control methods, is developed to reduce vibratory loads and noise of the rotor through modification of unsteady aerodynamic loads. Piezoelectric actuators installed inside the blade manipulate the motion of the trailing edge flap. The proposed blade rotates at higher speed and additional structures are included to support the actuators and the flap. This improves the design, as the blade is able to withstand increased centrifugal force. The cross-section of the active blade is designed first. A stress/strain recovery analysis is then conducted to verify its structural integrity. A one-dimensional beam analysis is also carried out to assist with the construction of the fan diagram. To select the actuator and design the flap actuation region, the flap hinge moment is estimated via a CFD analysis. To obtain the desired flap deflection of ±4 .deg. , three actuators are required. The design of the flap actuation region is validated using a test bed with a skin hinge. However, because the skin hinge induces additional flap hinge moment, it does not provide sufficient deflection angle. Therefore, the flap hinge is replaced by a pin-type hinge, and the results are evaluated.

  20. Technology and trend management at the interface of technology push and market pull

    DEFF Research Database (Denmark)

    Maier, Maximilian; Hofmann, Maximilian; Brem, Alexander

    2016-01-01

    Technology push and market pull innovation strategies are playing an important role for the effective management of ideas, technologies, and trends. The coexistence of these two approaches led to many debates and the focus switched several times from putting more effort into technology push aspects...... to fostering market pull approaches in the last decades. Still, there is no in-depth exploration of the interface of technology push and market pull and only few conceptual models are dealing with the connection between technology push and market pull in particular. Therefore, this study puts an exploratory...... focus on the innovation management processes of a global outdoor manufacturer with a special emphasis on the interface between technology push and market pull. From the case findings and our literature we conceptualise a non-linear innovation model that systematically integrates market pull...

  1. Reconstruction in extensive axillary Hidradenitis suppurativa with local fasciocutaneous V-Y advancement flaps

    Directory of Open Access Journals (Sweden)

    Sharma Ramesh

    2006-01-01

    Full Text Available We present our experience with the use of local fasciocutaneous V-Y advancement flaps in the reconstruction of 10 axillae in 6 patients for large defects following wide excision of long-standing Hidradenitis suppurativa of the axilla. The defects were closed with local V-Y subcutaneous island flaps. A single flap from the chest wall was sufficient for moderate defects. However, for larger defects, an additional flap was taken from the medial side of the ipsilateral arm. The donor defects could be closed primarily in all the patients. The local areas of the lateral chest wall and the medial side of the arm have a plentiful supply of cutaneous perforators and the flaps can be designed in a V-Y fashion without resorting to preoperative marking of the perforator. The flaps were freed sufficiently to allow adequate movement for closure of the defects. Although no attempt was made to identify the perforators specifically, many perforators were seen entering the flap. Some perforators can be safely divided to increase reach of the flap. All the flaps survived completely. A follow up of 2.5 years is presented.

  2. Push-pull alkenes: structure and p-electron distribution

    Directory of Open Access Journals (Sweden)

    ERICH KLEINPETER

    2006-01-01

    Full Text Available Push-pull alkenes are substituted alkenes with one or two electron-donating substituents on one end of C=C double bond and with one or two electron-accepting substituents at the other end. Allowance for p-electron delocalization leads to the central C=C double bond becoming ever more polarized and with rising push-pull character, the p-bond order of this double bond is reduced and, conversely, the corresponding p-bond orders of the C–Don and C–Acc bonds are accordingly increased. This push-pull effect is of decisive influence on both the dynamic behavior and the chemical reactivity of this class of compounds and thus it is of considerable interest to both determine and to quantify the inherent push-pull effect. Previously, the barriers to rotation about the C=C, C–Don and/or C–Acc partial double bonds (DG±, as determined by dynamic NMR spectroscopy or the 13C chemical shift difference of the polarized C=C partial double bond (DdC=C were employed for this purpose. However, these parameters can have serious limitations, viz. the barriers can be immeasurable on the NMR timescale (either by being too high or too low; heavily-biased conformers are present, etc. or DdC=C behaves in a non-additive manner with respect to the combination of the four substituents. Hence, a general parameter to quantify the push-pull effect is not yet available. Ab initio MO calculations on a collection of compounds, together with NBO analysis, provided valuable information on the structure, bond energies, electron occupancies and bonding/antibonding interactions. In addition to DG±C=C (either experimentally determined or theoretically calculated and DdC=C, the bond length of the C=C partial double bond was also examined and it proved to be a reliable parameter to quantify the push-pull effect. Equally so, the quotient of the occupation numbers of the antibonding andbonding p orbitals of the central C=C partial double bond ( p*C=C/ pC=C could also be employed for

  3. Propeller Flap for Complex Distal Leg Reconstruction: A Versatile ...

    African Journals Online (AJOL)

    equipment, cost, steep learning curve, and prolonged operating ... A Versatile Alternative when Reverse Sural Artery Flap is .... He had wound debridement, fracture reduction, and .... flaps that were raised in the patient and the logistics of limb.

  4. Versatility of the Angularis Oris Axial Pattern Flap for Facial Reconstruction.

    Science.gov (United States)

    Losinski, Sara L; Stanley, Bryden J; Schallberger, Sandra P; Nelson, Laura L; Towle Millard, Heather A M

    2015-11-01

    To describe the versatility of the axial pattern flap based on the cutaneous perforating branch of the angularis oris artery for reconstruction of large facial defects in dogs, including complications and clinical outcomes. Retrospective clinical case series. Client-owned dogs (n = 8). Facial flaps (n = 9) based at the commissure of the lip with a caudodorsal orientation were utilized, with established anatomical borders. Flaps were elevated deep to the panniculus carnosus in a caudal to rostral direction, preserving the angularis oris artery, its cutaneous perforator, and surrounding cutaneous vasculature. Flaps were rotated dorsally or ventrally to cover the defect. Primary closure of the donor site was by direct apposition in all cases. Angularis oris axial pattern flaps were most commonly used to close large defects of the nasomaxillary area rostral to the eyes (6 dogs), followed by orbital (2) and intermandibular (1) defects. Defects occurred because of tumor resection (6 dogs), trauma (2), and a chronic, non-healing wounding (1). All flaps healed with acceptable functional and cosmetic outcomes without major complications. Followup ranged from 10 days to 16 months. Minor postoperative complications included flap edema (8 dogs), partial incisional dehiscence (3), distal tip necrosis (2), and oroantral fistula recurrence (1). Angularis oris axial pattern flaps provided hirsute, full-thickness skin coverage of a variety of large facial defects with minor complications, and should be considered when restructuring large defects of the rostral face or chin. © Copyright 2015 by The American College of Veterinary Surgeons.

  5. Osteoradionecrosis of the olecranon: treatment by radial forearm flap

    International Nuclear Information System (INIS)

    Thornton, J.W.; Stevenson, T.R.; VanderKolk, C.A.

    1987-01-01

    Osteoradionecrosis of the olecranon is an unusual pathologic entity, treated best by debridement and wound closure using vascularized tissue. Local skin is often unavailable for flap design and transposition. The radial forearm flap can be isolated on a proximal vascular pedicle and transposed to cover the wound. In the case presented, healing was brisk and complete, allowing early elbow mobilization. Although the donor site is not easily concealed, no functional impairment results from flap elevation and all full-thickness wounds are confined to the involved extremity

  6. Late Onset of CSF Rhinorrhea in a Postoperative Transsphenoidal Surgery Patient Following Robotic-Assisted Abdominal Hysterectomy

    Directory of Open Access Journals (Sweden)

    Justin T. Dowdy MD

    2014-01-01

    Full Text Available Cerebrospinal fluid (CSF leak is the most commonly encountered perioperative complication in transsphenoidal surgery for pituitary lesions. Direct closure with a combination of autologous fat, local bone, and/or synthetic grafts remains the standard of care for leaks encountered at the time of surgery as well as postoperatively. The development of the vascularized nasoseptal flap as a closure technique has increased the surgeon’s capacity to correct even larger openings in the dura of the sella as well as widely exposed anterior skull base defects. Yet these advances in the technical nuances for management of post-transsphenoidal CSF leak are useless without the ability to recognize a CSF leak by physical examination, clinical history, biochemical testing, or radiographic assessment. Here, we report a case of a patient who developed a CSF leak 28 years after transsphenoidal surgery, precipitated by a robotic-assisted hysterectomy during which increased intra-abdominal pressure and steep Trendelenberg positioning were both factors. Given the remote nature of the patient’s transsphenoidal surgery and relative paucity of data regarding such a complication, the condition went unrecognized for several months. We review the available literature regarding risk and pathophysiology of CSF leak following abdominal surgery and propose the need for increased vigilance in identification of such occurrences with the increasing acceptance and popularity of minimally invasive abdominal and pelvic surgeries as standards in the field.

  7. Repair of large palatal fistula using tongue flap

    Directory of Open Access Journals (Sweden)

    Fejjal Nawfal

    2014-01-01

    Full Text Available Large palatal fistulas are a challenging problem in cleft surgery. Many techniques are used to close the defect. The tongue flap is an easy and reproductible procedure for managing this complication. The authors report a case of a large palatal fistula closure with anteriorly based tongue flap.

  8. Regional Myocutaneous Flaps for Head and Neck Reconstruction ...

    African Journals Online (AJOL)

    Regional myocutaneous pedicle flaps (RMF) are known to be relevant in the reconstruction of major head and neck oncologic defects with pectoralis major myocutaneous pedicle flap (PMMC) being the best-known RMF. For over three decades, since first described by Ariyan in 1979, PMMC has continually been used in the ...

  9. Lithospheric-scale centrifuge models of pull-apart basins

    Science.gov (United States)

    Corti, Giacomo; Dooley, Tim P.

    2015-11-01

    We present here the results of the first lithospheric-scale centrifuge models of pull-apart basins. The experiments simulate relative displacement of two lithospheric blocks along two offset master faults, with the presence of a weak zone in the offset area localising deformation during strike-slip displacement. Reproducing the entire lithosphere-asthenosphere system provides boundary conditions that are more realistic than the horizontal detachment in traditional 1 g experiments and thus provide a better approximation of the dynamic evolution of natural pull-apart basins. Model results show that local extension in the pull-apart basins is accommodated through development of oblique-slip faulting at the basin margins and cross-basin faults obliquely cutting the rift depression. As observed in previous modelling studies, our centrifuge experiments suggest that the angle of offset between the master fault segments is one of the most important parameters controlling the architecture of pull-apart basins: the basins are lozenge shaped in the case of underlapping master faults, lazy-Z shaped in case of neutral offset and rhomboidal shaped for overlapping master faults. Model cross sections show significant along-strike variations in basin morphology, with transition from narrow V- and U-shaped grabens to a more symmetric, boxlike geometry passing from the basin terminations to the basin centre; a flip in the dominance of the sidewall faults from one end of the basin to the other is observed in all models. These geometries are also typical of 1 g models and characterise several pull-apart basins worldwide. Our models show that the complex faulting in the upper brittle layer corresponds at depth to strong thinning of the ductile layer in the weak zone; a rise of the base of the lithosphere occurs beneath the basin, and maximum lithospheric thinning roughly corresponds to the areas of maximum surface subsidence (i.e., the basin depocentre).

  10. The expanded "BAT" flap for treatment of male pattern baldness.

    Science.gov (United States)

    Anderson, R D

    1993-11-01

    A new combination of expanded simultaneous transposition and advancement flaps is reported for the treatment of extensive male pattern baldness. Although vertical transposition and parieto-occipital advancement flaps in themselves are not new, their combination and simultaneous bilateral use combined with the use of expansion is new. The advantages of the expanded bilateral advancement transposition flap procedure are presented, along with the technique and results. The results are predictable, providing a more pleasing result, with a natural immediate temporal recession, avoidance of temporal dog-ears, and desirable anterior-superior direction of hair growth. Although flaps do require surgical skill and training, and there are risks and possible complications involved, the results are achieved in a relatively short time compared with grafting techniques. Flaps also provide the advantages of a full and natural hairline contrasted with the sparse look afforded by multiple grafts. The described procedures are very effective and reliable when properly planned and properly executed.

  11. Orbital floor reconstruction with free flaps after maxillectomy.

    Science.gov (United States)

    Sampathirao, Leela Mohan C S R; Thankappan, Krishnakumar; Duraisamy, Sriprakash; Hedne, Naveen; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania

    2013-06-01

    Background The purpose of this study is to evaluate the outcome of orbital floor reconstruction with free flaps after maxillectomy. Methods This was a retrospective analysis of 34 consecutive patients who underwent maxillectomy with orbital floor removal for malignancies, reconstructed with free flaps. A cross-sectional survey to assess the functional and esthetic outcome was done in 28 patients who were alive and disease-free, with a minimum of 6 months of follow-up. Results Twenty-six patients had bony reconstruction, and eight had soft tissue reconstruction. Free fibula flap was the commonest flap used (n = 14). Visual acuity was normal in 86%. Eye movements were normal in 92%. Abnormal globe position resulted in nine patients. Esthetic satisfaction was good in 19 patients (68%). Though there was no statistically significant difference in outcome of visual acuity, eye movement, and patient esthetic satisfaction between patients with bony and soft tissue reconstruction, more patients without bony reconstruction had abnormal globe position (p = 0.040). Conclusion Free tissue transfer has improved the results of orbital floor reconstruction after total maxillectomy, preserving the eye. Good functional and esthetic outcome was achieved. Though our study favors a bony orbital reconstruction, a larger study with adequate power and equal distribution of patients among the groups would be needed to determine this. Free fibula flap remains the commonest choice when a bony reconstruction is contemplated.

  12. Mucoperiosteal Flap Necrosis after Primary Palatoplasty in Patients with Cleft Palate

    Science.gov (United States)

    Cotrina-Rabanal, Omar; Barrenechea-Tarazona, Luis; Vargas-Chanduvi, Roberto; Paredes-Aponte, Luis; Romero-Narvaez, Carolina

    2017-01-01

    Background The prevalence of flap necrosis after palatoplasty in patients with cleft palate. The prevalence of mucoperiosteal flap necrosis after palatoplasty remains unknown, and this complication is rare. This event is highly undesirable for both the patient and the surgeon. We present here a new scale to evaluate the degree of hypoplasia of the palate and identify patients with cleft palate at high risk for the development of this complication. Methods In this case series, a 20-year retrospective analysis (1994–2014) identified patients from our records (medical records and screening day registries) with nonsyndromic cleft palate who underwent operations at 3 centers. All of these patients underwent operations using 2-flap palatoplasty and also underwent a physical examination with photographs and documentation of the presence of palatal flap necrosis after primary palatoplasty. Results Palatal flap necrosis was observed in 4 cases out of 1,174 palatoplasties performed at these centers. The observed prevalence of palatal flap necrosis in these groups was 0.34%. Conclusions The prevalence of flap necrosis can be reduced by careful preoperative planning, and prevention is possible. The scale proposed here may help to prevent this complication; however, further studies are necessary to validate its utility. PMID:28573096

  13. Mucoperiosteal Flap Necrosis after Primary Palatoplasty in Patients with Cleft Palate

    Directory of Open Access Journals (Sweden)

    Percy Rossell-Perry

    2017-05-01

    Full Text Available BackgroundThe prevalence of flap necrosis after palatoplasty in patients with cleft palate. The prevalence of mucoperiosteal flap necrosis after palatoplasty remains unknown, and this complication is rare. This event is highly undesirable for both the patient and the surgeon. We present here a new scale to evaluate the degree of hypoplasia of the palate and identify patients with cleft palate at high risk for the development of this complication.MethodsIn this case series, a 20-year retrospective analysis (1994–2014 identified patients from our records (medical records and screening day registries with nonsyndromic cleft palate who underwent operations at 3 centers. All of these patients underwent operations using 2-flap palatoplasty and also underwent a physical examination with photographs and documentation of the presence of palatal flap necrosis after primary palatoplasty.ResultsPalatal flap necrosis was observed in 4 cases out of 1,174 palatoplasties performed at these centers. The observed prevalence of palatal flap necrosis in these groups was 0.34%.ConclusionsThe prevalence of flap necrosis can be reduced by careful preoperative planning, and prevention is possible. The scale proposed here may help to prevent this complication; however, further studies are necessary to validate its utility.

  14. An international comparison of reimbursement for DIEAP flap breast reconstruction.

    Science.gov (United States)

    Reid, A W N; Szpalski, C; Sheppard, N N; Morrison, C M; Blondeel, P N

    2015-11-01

    The deep inferior epigastric artery perforator (DIEAP) flap is currently considered the gold standard for autologous breast reconstruction. With the current economic climate and health cutbacks, we decided to survey reimbursement for DIEAP flaps performed at the main international centres in order to assess whether they are funded consistently. Data were collected confidentially from the main international centres by an anonymous questionnaire. Our results illustrate the wide disparity in international DIEAP flap breast reconstruction reimbursement: a unilateral DIEAP flap performed in New York, USA, attracts €20,759, whereas the same operation in Madrid, Spain, will only be reimbursed for €300. Only 35.7% of the surgeons can set up their own fee. Moreover, 85.7% of the participants estimated that the current fees are insufficient, and most of them feel that we are evolving towards an even lower reimbursement rate. In 55.8% of the countries represented, there is no DIEAP-specific coding; in comparison, 74.4% of the represented countries have a specific coding for transverse rectus abdominis (TRAM) flaps. Finally, despite the fact that DIEAP flaps have become the gold standard for breast reconstruction, they comprise only a small percentage of all the total number of breast reconstruction procedures performed (7-15%), with the only exception being Belgium (40%). Our results demonstrate that DIEAP flap breast reconstruction is inconsistently funded. Unfortunately though, it appears that the current reimbursement offered by many countries may dissuade institutions and surgeons from offering this procedure. However, substantial evidence exists supporting the cost-effectiveness of perforator flaps for breast reconstruction, and, in our opinion, the long-term clinical benefits for our patients are so important that this investment of time and money is absolutely essential. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons

  15. Therapy of deep radiation ulcer after the mammacarcinoma operation

    International Nuclear Information System (INIS)

    Nabeshima, Kengo; Imai, Susumu; Makino, Koreo; Koike, Makoto; Hayata, Yoshiharu.

    1976-01-01

    Eight cases of deep radiation ulcer after mammacarcinoma operations were treated in our clinic in the past 10 years. Four of them were treated by the large thoracic-abdominal flap after bony chest wall resection. Referring to these experiences we considered that the following four points were important. 1. Ulcers should be repaired in one stage if possible. 2. Necrotic mass and injured tissues should be resected completely. 3. The large tissue defect after the debridement can be covered directly with the opposite large thoracic-abdominal flap. 4. The I. II. III perforating branches of the internal mammary arteries should be kept intract in constructing the thoracic-abdominal flap. (auth.)

  16. Plantar flaps based on perforators of the plantar metatarsal/common digital arteries.

    Science.gov (United States)

    Valentin, Georgescu Alexandru; Rodica, Matei Ileana; Manuel, Llusa

    2014-09-01

    Because of the unique characteristics of its integument, the affirmation "replacing like with like" becomes more than evident in the reconstruction of defects of the ultraspecialized plantar skin. But, the paucity of local resources, and especially in the forefoot, transforms this attempt in a very challenging problem. Many techniques, including skin grafts and various types of flaps were used in the management of defects in the forefoot. We present a new useful flap in the reconstruction of skin defects in the forefoot, based on small perforator vessels originating either from the plantar metatarsal arteries or plantar common digital arteries. Starting with June 2011, this flap was performed, as plantar transposition perforator flap, plantar propeller flap, or plantar propeller perforator plus flap, in seven patients with ulcers over the plantar forefoot. During a follow-up of 7 to 17 months (mean, 9.8 months), the local evolution regarding flap integration, pain, relapse, sensitive recovery, donor site, and footwear quality was analyzed. We registered a 100% survival rate of the flaps, with delayed healing in only one case. The gait resumption was possible after 6 weeks in all cases. This new flap, based on small perforator vessels from the plantar metatarsal or common digital arteries, and which provides a good, stable, and sensory recovery, seems to be a promising method in the reconstruction of plantar skin defects over the metatarsal heads. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Obesity Should Not Prevent from TRAM Flap Breast Reconstruction in Developing Countries.

    Science.gov (United States)

    Alipour, Sadaf; Omranipour, Ramesh; Akrami, Rahim

    2015-12-01

    Transverse rectus abdominis musculocutaneous (TRAM) flap is the most common procedure performed for breast reconstruction after mastectomy for breast cancer. Obesity is a relative contraindication, and complex modifications have been proposed in the pedicled technique for obese patients. We studied ischemic complications in our patients to investigate the effect of body weight on the outcome of TRAM flap breast reconstruction. Pertinent data from medical records of patients receiving a TRAM flap surgery from 1986 to 2011 were extracted. Patients were divided into three groups based on the body mass index (BMI): normal (obese (>30 kg/m(2)). Flap necrosis is defined as any visible nonviable tissue in the reconstructed breast. It was observed that 117 patients had received TRAM flap reconstruction. Fifty-eight patients were excluded. Of the remaining 59 cases, 24 had normal BMI, 21 were overweight, and 14 were obese. No patient was found to develop flap necrosis. Outcome of TRAM flap breast reconstruction in obese patients is similar to nonobese patients. No major necrosis in need of reoperation was identified in the studied obese patients. It was concluded that categorizing obesity as a relative contraindication to TRAM flap breast reconstruction should be revisited based on larger cohort studies.

  18. Dual-dermal-barrier fashion flaps for the treatment of sacral pressure sores.

    Science.gov (United States)

    Hsiao, Yen-Chang; Chuang, Shiow-Shuh

    2015-02-01

    The sacral region is one of the most vulnerable sites for the development of pressure sores. Even when surgical reconstruction is performed, there is a high chance of recurrence. Therefore, the concept of dual-dermal-barrier fashion flaps for sacral pressure sore reconstruction was proposed. From September 2007 to June 2010, nine patients with grade IV sacral pressures were enrolled. Four patients received bilateral myocutaneous V-Y flaps, four patients received bilateral fasciocutaneous V-Y flaps, and one patient received bilateral rotation-advanced flaps for sacral pressure reconstruction. The flaps were designed based on the perforators of the superior gluteal artery in one patient's reconstructive procedure. All flaps' designs were based on dual-dermal-barrier fashion. The mean follow-up time was 16 months (range = 12-25). No recurrence was noted. Only one patient had a complication of mild dehiscence at the middle suture line, occurring 2 weeks after the reconstructive surgery. The dual-dermal fashion flaps are easily duplicated and versatile. The study has shown minimal morbidity and a reasonable outcome.

  19. Pulling an intruder from a granular material: a novel depinning experiment

    Directory of Open Access Journals (Sweden)

    Zhang Yue

    2017-01-01

    Full Text Available Two-dimensional impact experiments by Clark et al. [2] identified the source of inertial drag to be caused by ‘collisions’ with a latent force network, leading to large fluctuations of the force experienced by the impactor. These collisions provided the major drag on an impacting intruder until the intruder was nearly at rest. As a complement, we consider controlled pull-out experiments where a buried intruder is pulled out of a material, starting from rest. This provides a means to better understand the non-inertial part of the drag force, and to explore the mechanisms associated with the force fluctuations. To some extent, the pull out process is a time reversed version of the impact process. In order to visualize this pulling process, we use 2D photoelastic disks from which circular intruders of different radii are pulled out. We present results about the dynamics of the intruder and the structures of the force chains inside the granular system as captured by slow and high speed imaging.

  20. Reconstruction of hand contracture by reverse ulnar perforator flap

    Directory of Open Access Journals (Sweden)

    Cengiz Eser

    2016-04-01

    Full Text Available Hand burn scar contractures affect patients in aesthetic and functional aspects. After releasing these scars, the defects should be repaired. The reconstruction methods include primary suturation, Z plasty, skin grafting, local or free flaps, etc. All methods have their own advantages and disadvantages. One of the most useful flaps is the reverse ulnar perforator flap. We performed a two-staged procedure for repairing a post-burn contracture release defect in a 40-year-old male. In the first stage we applied reverse ulnar perforator flap for the hand defect, and ulnar artery and vein repair in the second stage. In conclusion, this two-staged procedure is a non-primary but useful option for hand and finger defects and prevents major vascular structure damage of the forearm. [Hand Microsurg 2016; 5(1.000: 40-43

  1. Reconstruction of palatal defect using mucoperiosteal hinge flap and pushback palatoplasty.

    Science.gov (United States)

    Lee, S I; Lee, H S; Hwang, K

    2001-11-01

    This article describes a simple, new surgical technique to provide a complete two-layer closure of palatal defect resulting from a surgical complication of trans palatal resection of skull base chordoma. The nasal layer was reconstructed with triangular shape oral mucoperiosteal turn over hinge flap based on anterior margin of palatal defect and rectangular shaped lateral nasal mucosal hinge flaps. The oral layer was reconstructed with conventional pushback V-Y advancement 2-flaps palatoplasty. Each layer of the flaps were secured with two key mattress suture for flap coaptation. This technique has some advantages: simple, short operation time, one-stage procedure, no need of osteotomy. It can close small- to medium-sized palatal defect of palate or wide cleft palate and can prevent common complication of oronasal fistula, which could be caused by tension.

  2. Oil pulling: A traditional method on the edge of evidence

    Directory of Open Access Journals (Sweden)

    H Mythri

    2017-01-01

    Full Text Available Introduction: Oil pulling is an ancient, traditional folk remedy that has been practiced for centuries in India and southern Asia as a holistic Ayurvedic technique. The practice of oil pulling involves placing a tablespoon of an edible oil (e.g. sesame, olive, sunflower, coconut inside the mouth, and swishing or “pulling” the oil through the teeth and oral cavity for anywhere from 1–5 minutes to up to 20 minutes or longer. Materials and Methods: Articles related to oil pulling were collected by using oil pulling as Keyword in Google and Medline. Out of the 21 related articles published till 2016, 6 articles with the proper study designs were used for analysis. Results: The studies were unreliable for many reasons, including the misinterpretation of results due to small sample size and improper study design. Conclusion: Though the promoters claim it as one of the best method to be as adjuvant to mechanical control methods, scientific evidences are lacking.

  3. Airfoil-Wake Modification with Gurney Flap at Low Reynolds Number

    Science.gov (United States)

    Gopalakrishnan Meena, Muralikrishnan; Taira, Kunihiko; Asai, Keisuke

    2018-04-01

    The complex wake modifications produced by a Gurney flap on symmetric NACA airfoils at low Reynolds number are investigated. Two-dimensional incompressible flows over NACA 0000 (flat plate), 0006, 0012 and 0018 airfoils at a Reynolds number of $Re = 1000$ are analyzed numerically to examine the flow modifications generated by the flaps for achieving lift enhancement. While high lift can be attained by the Gurney flap on airfoils at high angles of attack, highly unsteady nature of the aerodynamic forces are also observed. Analysis of the wake structures along with the lift spectra reveals four characteristic wake modes (steady, 2S, P and 2P), influencing the aerodynamic performance. The effects of the flap over wide range of angles of attack and flap heights are considered to identify the occurrence of these wake modes, and are encapsulated in a wake classification diagram. Companion three-dimensional simulations are also performed to examine the influence of three-dimensionality on the wake regimes. The spanwise instabilities that appear for higher angles of attack are found to suppress the emergence of the 2P mode. The use of the wake classification diagram as a guidance for Gurney flap selection at different operating conditions to achieve the required aerodynamic performance is discussed.

  4. Reverse saphenous conduit flap in small animals: Clinical applications and outcomes

    Directory of Open Access Journals (Sweden)

    Ross C. Elliott

    2014-08-01

    Full Text Available Due to the lack of skin elasticity defects of the distal hind limb can be a challenge to close. This article assesses a well-described, but completely under-used technique for closure of wounds on the distal tarsus. The technique was used with good success in six cases presenting to the Bryanston Veterinary Hospital with a wide range of underlying pathology ranging from trauma to neoplastic disease of the tarsus. All six cases were treated with a reverse saphenous conduit flap and two of them underwent radiation therapy with no adverse side effects. All cases showed excellent results with a very low degree of flap necrosis that never exceeded 15% of the total flap area. This skin flap provides an excellent treatment method that is reliable in closure of defects of the distal tarsus with few adverse effects. To the author’s knowledge there has been only one previously published report on the clinical use of this type of skin flap,even though the flap is well described in most texts.

  5. Pull-production in repetitive remanufacturing

    Energy Technology Data Exchange (ETDEWEB)

    McCaskey, D.W. Jr.

    1992-09-01

    In the past, production activity control practices in most repetitive remanufacturing facilities resembled those used in intermittent production operations. These operations were characterized by large amounts of work-in-process (WIP), frequent work stoppages due to part shortages, excessive overtime, low product velocity, informal scheduling between dependent operations, low employee and management moral, and a lot of wasted time, material, labor, and space. Improvement in production activity control (PAC) methods for repetitive remanufactures has been hampered by uncertainty in: supply of incoming assets, configuration of assets, process times to refurbish assets, and yields in reclamation processes. collectively these uncertainties make shop floor operations seem uncontrollable. However, one United States Army depot has taken on the challenge. Through management supported, cross-functional teams, the Tooele Army Depot has designed and implemented pull-production systems for two of its major products, with several others to follow. This article presents a generalized version of Tooele`s pull-production system and highlights design characteristics which are specific to remanufacturing applications.

  6. Pull-production in repetitive remanufacturing

    Energy Technology Data Exchange (ETDEWEB)

    McCaskey, D.W. Jr.

    1992-09-01

    In the past, production activity control practices in most repetitive remanufacturing facilities resembled those used in intermittent production operations. These operations were characterized by large amounts of work-in-process (WIP), frequent work stoppages due to part shortages, excessive overtime, low product velocity, informal scheduling between dependent operations, low employee and management moral, and a lot of wasted time, material, labor, and space. Improvement in production activity control (PAC) methods for repetitive remanufactures has been hampered by uncertainty in: supply of incoming assets, configuration of assets, process times to refurbish assets, and yields in reclamation processes. collectively these uncertainties make shop floor operations seem uncontrollable. However, one United States Army depot has taken on the challenge. Through management supported, cross-functional teams, the Tooele Army Depot has designed and implemented pull-production systems for two of its major products, with several others to follow. This article presents a generalized version of Tooele's pull-production system and highlights design characteristics which are specific to remanufacturing applications.

  7. Aerodynamic characteristics of NACA 4412 airfoil section with flap in extreme ground effect

    Directory of Open Access Journals (Sweden)

    Alex E. Ockfen

    2009-09-01

    Full Text Available Wing-in-Ground vehicles and aerodynamically assisted boats take advantage of increased lift and reduced drag of wing sections in the ground proximity. At relatively low speeds or heavy payloads of these craft, a flap at the wing trailing-edge can be applied to boost the aerodynamic lift. The influence of a flap on the two-dimensional NACA 4412 airfoil in viscous ground-effect flow is numerically investigated in this study. The computational method consists of a steady-state, incompressible, finite volume method utilizing the Spalart-Allmaras turbulence model. Grid generation and solution of the Navier-Stokes equations are completed using computer program Fluent. The code is validated against published experimental and numerical results of unbounded flow with a flap, as well as ground-effect motion without a flap. Aerodynamic forces are calculated, and the effects of angle of attack, Reynolds number, ground height, and flap deflection are presented for a split and plain flap. Changes in the flow introduced with the flap addition are also discussed. Overall, the use of a flap on wings with small attack angles is found to be beneficial for small flap deflections up to 5% of the chord, where the contribution of lift augmentation exceeds the drag increase, yielding an augmented lift-to-drag ratio.

  8. Comparative study of 2 commissural dorsal flap techniques for the treatment of congenital syndactyly.

    Science.gov (United States)

    Mallet, Cindy; Ilharreborde, Brice; Jehanno, Pascal; Litzelmann, Estelle; Valenti, Philippe; Mazda, Keyvan; Penneçot, Georges-François; Fitoussi, Franck

    2013-03-01

    Many commissural reconstruction techniques have been described for the treatment of syndactyly. This study is the first to compare long-term results of 2 commissural dorsal flap procedures (T-flap and omega-flap). Fifty-nine web-spaces in 39 patients, operated on between 1991 and 2008, were retrospectively analyzed. Thirty-six T-flap and 23 omega-flap procedures were performed using full-thickness skin graft in every case for digital resurfacing. Factors that could affect the long-term outcome were collected, including development of web-creep, clinodactyly, and flexion contracture. Patients were reviewed with a mean follow-up of 5 years and 8 months. Preoperative complexity of syndactyly influenced the development of clinodactyly and flexion contracture. Among the patients who developed clinodactyly, 96% had surgery for complex syndactyly. No difference was found between the 2 flap methods concerning digital deformation and mobility. However, web-creep occurred more frequently after T-flap than after omega-flap procedures (17% vs. 5%). The combination of either dorsal commissural T-flaps or omega-flaps with full-thickness graft to resurface digits is a reliable technique for the treatment of syndactyly with satisfactory functional and cosmetic results. Long-term results are not influenced by the type of flap. Nevertheless, the omega-flap technique, using 2 triangular lateral-palmar flaps, avoids use of skin graft to cover lateral-palmar aspects of the new commissure, consequently reducing the incidence of web-creep. In cases of syndactyly, the primary prognostic factor is whether the patient has simple or complex syndactyly. In complex syndactyly, the risk of long-term unfavorable results is higher. When complex complicated syndactyly is involved, postoperative complication rates increase. Level III.

  9. Station Program Note Pull Automation

    Science.gov (United States)

    Delgado, Ivan

    2016-01-01

    Upon commencement of my internship, I was in charge of maintaining the CoFR (Certificate of Flight Readiness) Tool. The tool acquires data from existing Excel workbooks on NASA's and Boeing's databases to create a new spreadsheet listing out all the potential safety concerns for upcoming flights and software transitions. Since the application was written in Visual Basic, I had to learn a new programming language and prepare to handle any malfunctions within the program. Shortly afterwards, I was given the assignment to automate the Station Program Note (SPN) Pull process. I developed an application, in Python, that generated a GUI (Graphical User Interface) that will be used by the International Space Station Safety & Mission Assurance team here at Johnson Space Center. The application will allow its users to download online files with the click of a button, import SPN's based on three different pulls, instantly manipulate and filter spreadsheets, and compare the three sources to determine which active SPN's (Station Program Notes) must be reviewed for any upcoming flights, missions, and/or software transitions. Initially, to perform the NASA SPN pull (one of three), I had created the program to allow the user to login to a secure webpage that stores data, input specific parameters, and retrieve the desired SPN's based on their inputs. However, to avoid any conflicts with sustainment, I altered it so that the user may login and download the NASA file independently. After the user has downloaded the file with the click of a button, I defined the program to check for any outdated or pre-existing files, for successful downloads, to acquire the spreadsheet, convert it from a text file to a comma separated file and finally into an Excel spreadsheet to be filtered and later scrutinized for specific SPN numbers. Once this file has been automatically manipulated to provide only the SPN numbers that are desired, they are stored in a global variable, shown on the GUI, and

  10. Optimal placement of trailing-edge flaps for helicopter vibration reduction using response surface methods

    Science.gov (United States)

    Viswamurthy, S. R.; Ganguli, Ranjan

    2007-03-01

    This study aims to determine optimal locations of dual trailing-edge flaps to achieve minimum hub vibration levels in a helicopter, while incurring low penalty in terms of required trailing-edge flap control power. An aeroelastic analysis based on finite elements in space and time is used in conjunction with an optimal control algorithm to determine the flap time history for vibration minimization. The reduced hub vibration levels and required flap control power (due to flap motion) are the two objectives considered in this study and the flap locations along the blade are the design variables. It is found that second order polynomial response surfaces based on the central composite design of the theory of design of experiments describe both objectives adequately. Numerical studies for a four-bladed hingeless rotor show that both objectives are more sensitive to outboard flap location compared to the inboard flap location by an order of magnitude. Optimization results show a disjoint Pareto surface between the two objectives. Two interesting design points are obtained. The first design gives 77 percent vibration reduction from baseline conditions (no flap motion) with a 7 percent increase in flap power compared to the initial design. The second design yields 70 percent reduction in hub vibration with a 27 percent reduction in flap power from the initial design.

  11. Closed-Loop Control of Constrained Flapping Wing Micro Air Vehicles

    Science.gov (United States)

    2014-03-27

    predicts forces and moments for the class of flapping wing fliers that makes up most insects and hummingbirds. Large bird and butterfly “clap- and...Closed-Loop Control of Constrained Flapping Wing Micro Air Vehicles DISSERTATION Garrison J. Lindholm, Captain, USAF AFIT-ENY-DS-14-M-02 DEPARTMENT...States Air Force, Department of Defense, or the United States Government. AFIT-ENY-DS-14-M-02 Closed-Loop Control of Constrained Flapping Wing Micro Air

  12. Surgical revirgination: Four vaginal mucosal flaps for reconstruction of a hymen

    Directory of Open Access Journals (Sweden)

    Hemant A Saraiya

    2015-01-01

    Full Text Available Introduction: Over centuries, virginity has been given social, religious and moral importance. It is widely believed as a state of a female who has never engaged in sexual intercourse, and her hymen is intact. Hymenoplasty for torn hymen is carried out not only for the sake of cultural and religious traditions but also for the social status and interpersonal relationships. Materials and Methods: 2.5 cm long and 1 cm wide four vaginal mucosal flaps were raised from the anterior vaginal wall just behind labia minora. Two flaps were based proximally, and their two opposing flaps were based distally. These flaps were overlapped in a crisscross fashion and were sutured with 5/0 Polyglactin (Vicryl® sutures leaving no area raw. The donor area was closed primarily. When some remains of a torn hymen were found, one to three vaginal mucosal flaps were added to its remains as per the need for reconstruction. Results: We operated upon 11 patients. In nine cases, the hymen was reconstructed with four flaps. In remaining two, it was reconstructed from the remains using vaginal mucosal flaps. All flaps healed without any infection or disruption. Sutures got absorbed in 25-35 days. In all cases, this newly constructed barrier broke with only moderate pressure at the time of penetrative sex serving the purpose of the surgery completely. Conclusion: Erasing evidence of the sexual history simply by ′Surgical Revirgination′ is extremely important to women contemplating marriage in cultures where a high value is placed on virginity.

  13. Reconstruction of fingers after electrical injury using lateral tarsal artery flap

    Directory of Open Access Journals (Sweden)

    Zhang MH

    2017-07-01

    Full Text Available Minghua Zhang, Mitao Huang, Pihong Zhang, Pengfei Liang, Licheng Ren, Jizhang Zeng, Jie Zhou, Xiong Liu, Tinghong Xie, Xiaoyuan Huang Department of Burns Reconstruction Surgery, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of China Objective: Electrical injuries to the fingers account for the majority of total severe burns that occur each year. While several types of flaps have been used in covering finger defects, all have limitations or disadvantages. The purpose of this study was to introduce our clinical experiences of using the lateral tarsal artery (LTA flap to successfully restore fingers after electrical injury.Patients and methods: From 2005 to 2012, 10 patients with 14 severe electrical burns to their fingers, including six thumbs and four index and four middle fingers, were treated with LTA flap. The wound size ranged from 2.0×3.0 cm to 3.5×5.0 cm. The flap with free tendon graft was used to repair the tendon defect in four cases, free nerve graft was used to repair the feeling defect in two cases, and the flap with nerve was used to repair the feeling defect in two cases. All the patients were followed up for 3 months to 2 years.Results: All skin flaps adhered successfully and there were no complications. All patients were satisfied with the esthetic appearance and functional outcome of the finger reconstruction.Conclusion: LTA flap is a reliable method to restore fingers after severe electrical injuries. Keywords: electrical injuries to fingers, lateral tarsal artery flap

  14. Affective and Sensory Correlates of Hair Pulling in Pediatric Trichotillomania

    Science.gov (United States)

    Meunier, Suzanne A.; Tolin, David F.; Franklin, Martin

    2009-01-01

    Hair pulling in pediatric populations has not received adequate empirical study. Investigations of the affective and sensory states contributing to the etiology and maintenance of hair pulling may help to elucidate the classification of trichotillomania (TTM) as an impulse control disorder or obsessive-compulsive spectrum disorder. The current…

  15. Force direction in pushing and pulling and Musculo-Skeletal load

    NARCIS (Netherlands)

    Looze, M.P. de; Kuijer, P.P.F.M.

    1999-01-01

    In pushing and pulling wheeled objects, the effect of the exerted force on local musculo-skeletal loads depends on the direction of force exertion. Several questions about the direction of force exertion in pushing and pulling, the effects of handle height and force level on force direction, and the

  16. Application of Indocyanine Green in Flap Surgery: A Systematic Review.

    Science.gov (United States)

    Li, Ke; Zhang, Zheng; Nicoli, Fabio; D'Ambrosia, Christopher; Xi, Wenjing; Lazzeri, Davide; Feng, Shaoqing; Su, Weijie; Li, Hua; Ciudad, Pedro; Tremp, Mathias; Zhang, Yi Xin

    2018-02-01

     The vascularization of the distal portions of transferred tissue represents the most critical factor in the success of reconstructive surgery. In recent years, indocyanine green (ICG) fluorescence imaging techniques have been applied during surgery to evaluate flap perfusion. However, this investigation has found that there is little consensus regarding the standard dose of ICG as well as the pre-operative requirements of ICG allergy testing. The aim of this study is to summarize the applications of ICG to tissue transfers and safe dosing practices and to provide insight to the possible adverse effects of ICG on flap surgery with the goal of helping clinicians apply ICG safely and efficiently to tissue transfer procedures.  A literature search was performed using, Wiley InterScience, and Springer with the key words, 'Flap,' 'indocyanine green,' 'surgery,' and related mesh words for all publications between 2005 and 2015. Title and abstract screening was performed using predefined in- and exclusion criteria.  Seventy-three articles were included. These were classified as "application of ICG in flap surgery" and "the security of applying ICG in flap surgery".  ICG fluorescence imaging preoperatively facilitates the detection of perforators in tissue flaps with thickness <20 mm, aids in the evaluation of flap microcirculation and perfusion, and allows surgeons to select dominant cutaneous nerves while evaluating the quality of vascular anastomoses and locating thromboses. The literature also concluded that potential allergic reactions to ICG should be taken into consideration. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. The anatomy of forearm free flap phalloplasty for transgender surgery.

    Science.gov (United States)

    Kim, S; Dennis, M; Holland, J; Terrell, M; Loukas, M; Schober, J

    2018-03-01

    Transgender surgeries are becoming more frequent and visual interpretation of anatomy is essential for both surgeons and patients. Since the forearm free flap phalloplasty was introduced in 1984, it has been known to provide reliable cosmetic and functional results for transitioning men compared with phalloplasty by different flaps. Surgical text descriptions were enhanced by the creation of new anatomic illustrations. The forearm free flap consists of the anterior forearm skin, subcutaneous tissue, fascia containing the radial artery as the perforator and its venae comitantes, cephalic and basilic veins, and lateral and medial antebrachial cutaneous nerves are demonstrated in relation to the surgically derived flap. Song's forearm free flap phalloplasty requires two surgical stages with a three-month interval between the stages: prelamination of a neourethra and construction of a neophallus. The neophallus created by forearm flap phalloplasty is reported to achieve acceptable aesthetical and psychological satisfaction, appropriate size and shape, and satisfying sexual intercourse. Despite increasing experiences in gender confirming surgery with modifications made by many authors, urethral complications including fistula and/or stricture formation are the leading causes of reoperation. The poor esthetic outcome of the forearm donor site and a decrease in rigidity of the neophallus are the main limitations. Illustrations of anatomy help inform surgical choice and understanding of risks and benefits by patients. The anatomy of the free forearm flap phalloplasty supports creation of a neophallus for transsexual anatomy revision. Clin. Anat. 31:145-151, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    Science.gov (United States)

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  19. Versatality of supraclavicular flap in neck, face, and upper chest region coverage

    International Nuclear Information System (INIS)

    Almas, D.; Masood, T.; Dar, M.F.; Noman, B.

    2015-01-01

    The objective is to analyze the utility of the island supraclavicular flap in a region where skin graft cannot be used and free flap is not feasible. We assessed complications and functional outcomes. Study Design: Prospective descriptive study. Place and Duration of Study: The study was done at plastic and reconstructive surgery department CMH Rawalpindi during the period of 03 year from October 2011 to October 2014. Material and Patients: An island supraclavicular artery flap was used to reconstruct oncologic, and post burn neck contractures release defects. 30 patients were included in the study. Doppler probe was used to help with localization of vascular pedicle. All the patients with scarring in both shoulder regions, history of radiation to neck and undergoing radical neck dissection were excluded. Results: A total of 30 patients were included 20 (66.6%) male and 10 (33.3%) were female. Oncologicre section was followed by immediate reconstruction with island supraclavicular artery flap. Post burn contractures were released and covered by a pedicled supraclavicular artery flap. The recipient sites were neck, face, oral and upper chest region. The average harvest time was 1 and half hour. Donor site was closed primarily in 22 (73.3%) while 8 (26.6%) require skin grafting. Post burn contractures needed scar management with intralesional steroid, pressure garments and scar revision with Z-plasty in 4(13.3%) cases. 1 (3.3%) flap failed completely and the defect was covered with a skin graft. We had 01 (3.3%) mortality due to respiratory obstruction, despite adequate flap perfusion for 24 hours. Minor complications included, partial flap loss, seroma, and haematoma formation. In addition hypertrophied scar, spreading scar and keloid formation occurred at the donor site 18 (60%). Conclusion: Island supraclavicular artery flap with an easy learning curve is a reliable flap. It has a good colour and texture match with minimal donor site morbidity. It is an excellent

  20. Detour technique, Dipping technique, or IIeal bladder flap technique for surgical correction of uretero-ileal anastomotic stricture in orthotopic ileal neobladder

    Directory of Open Access Journals (Sweden)

    Mohamed Wishahi

    2015-08-01

    Full Text Available ABSTRACTBackground:Uretero-ileal anastomotic stricture (UIAS is a urological complication after ileal neobladder, the initial management being endourological intervention. If this fails or stricture recurs, surgical intervention will be indicated.Design and Participants:From 1994 to 2013, 129 patients were treated for UIAS after unsuccessful endourological intervention. Unilateral UIAS was present in 101 patients, and bilateral in 28 patients; total procedures were 157. The previous ileal neobladder techniques were Hautmann neobladder, detubularized U shape, or spherical shape neobladder.Surgical procedures:Dipping technique was performed in 74 UIAS. Detour technique was done in 60 renal units. Ileal Bladder flap was indicated in 23 renal units. Each procedure ended with insertion of double J, abdominal drain, and indwelling catheter.Results:Follow-up was done for 12 to 36 months. Patency of the anastomosis was found in 91.7 % of cases. Thirteen patients (8.3% underwent antegrade dilatation and insertion of double J.Conclusion:After endourological treatment for uretero-ileal anastomotic failure, basically three techniques may be indicated: dipping technique, detour technique, and ileal bladder flap. The indications are dependent on the length of the stenotic/dilated ureteral segment. Better results for long length of stenotic ureter are obtained with detour technique; for short length stenotic ureter dipping technique; when the stenotic segment is 5 cm or more with a short ureter, the ileal tube flap is indicated. The use of double J stent is mandatory in the majority of cases. Early intervention is the rule for protecting renal units from progressive loss of function.

  1. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-07-07

    Jul 7, 2015 ... muscle flaps, such as gracillis muscle flap, transverse abdominal muscle flap, and tensor fascia lata flap, and fascia cutaneous flaps, such as medial ... The artificial vagina. Am J Obstet Gynecol. 1967 Dec. 1;99(7):944-51. PubMed | Google Scholar. 2. Mclndoe AH, Banister JB. An operation for the cure of.

  2. Reliability of Free Radial Forearm Flap for Tongue Reconstruction Following Oncosurgical Resection

    Directory of Open Access Journals (Sweden)

    Gaurab Ranjan Chaudhuri

    2015-08-01

    Full Text Available Introduction Primary closure following oncosurgical resection of carcinoma tongue has been found to compromise tongue function in regards to speech and swallowing very badly. In contrast, reconstruction of tongue with free radial forearm flap following oncosurgical resection has shown promising functional outcome. Materials and Methods Thirteen patients (ten male and three female with squamous cell carcinoma involving anterior 2/3rd of tongue had undergone either hemiglossectomy or subtotal glossectomy. Reconstruction was done with free radial forearm flap following oncosurgical resection and neck dissection. All of them received postoperative radiotherapy. Follow-up ranged from 2 months to 2 years. The age of the patients ranged between 32 and 65 years. Flap dimension ranged from 7x6 cm to 10x8 cm. Vascular anastomosis performed in an end-to-end manner with 8-0 Ethilon® under loupe magnifiacation. Results Venous congestion occurred in one patient after 48 hours postoperatively and the flap underwent complete necrosis on postoperative day 5. Postoperative hematoma was found in one patient within first 24 hours of reconstruction. Re-exploration was done immediately, blood clots were removed. No fresh bleeding point was seen and the flap survived. In this series, 12 out of 13 flaps survived completely (92%. Conclusion The free radial forearm flap has become a workhorse flap in head and reconstruction due to its lack of extra bulk, relative ease of dissection, long vascular pedicle, good calibre vessels, malleability and minimal donor site morbidity. Furthermore its low flap loss and complication rate offer the best choice for tongue reconstruction.

  3. Facial reconstruction with a unique osteomyocutaneous DCIA perforator flap variant: a case report.

    Science.gov (United States)

    Wechselberger, G; Schwaiger, K; Hachleitner, J; Oberascher, G; Ensat, F; Larcher, L

    Anatomical variance of the deep circumflex iliac artery is of high clinical value in facial reconstruction using a deep circumflex iliac artery perforator (DCIAP) flap. We present the case of a 76-year-old woman treated with an osteomyocutaneous DCIAP flap variant for facial reconstruction. We also review here the literature on DCIA perforator flaps and the different anatomical variances, which might bring clinical benefits. The observed anatomy in our patient offered the possibility to raise a free flap variant with high mobility of a large skin paddle and a long vascular pedicle combined with a variable osteomuscular portion. The characteristics of the flap thus raised help overcome the disadvantages of the conventional DCIAP flap and offer excellent options for facial reconstruction.

  4. A Comparative Study of Simulated and Measured Gear-Flap Flow Interaction

    Science.gov (United States)

    Khorrami, Mehdi R.; Mineck, Raymond E.; Yao, Chungsheng; Jenkins, Luther N.; Fares, Ehab

    2015-01-01

    The ability of two CFD solvers to accurately characterize the transient, complex, interacting flowfield asso-ciated with a realistic gear-flap configuration is assessed via comparison of simulated flow with experimental measurements. The simulated results, obtained with NASA's FUN3D and Exa's PowerFLOW® for a high-fidelity, 18% scale semi-span model of a Gulfstream aircraft in landing configuration (39 deg flap deflection, main landing gear on and off) are compared to two-dimensional and stereo particle image velocimetry measurements taken within the gear-flap flow interaction region during wind tunnel tests of the model. As part of the bench-marking process, direct comparisons of the mean and fluctuating velocity fields are presented in the form of planar contour plots and extracted line profiles at measurement planes in various orientations stationed in the main gear wake. The measurement planes in the vicinity of the flap side edge and downstream of the flap trailing edge are used to highlight the effects of gear presence on tip vortex development and the ability of the computational tools to accurately capture such effects. The present study indicates that both computed datasets contain enough detail to construct a relatively accurate depiction of gear-flap flow interaction. Such a finding increases confidence in using the simulated volumetric flow solutions to examine the behavior of pertinent aer-odynamic mechanisms within the gear-flap interaction zone.

  5. The effects of epinephrine and dobutamine on skin flap viability in rats

    DEFF Research Database (Denmark)

    Krammer, Caspar W; Ibrahim, Rami Mossad; Hansen, Tom G

    2015-01-01

    BACKGROUND: Intraoperative reduction in arterial pressure may cause hypoperfusion of skin flaps, which may increase the risk of flap failure. There is no international consensus regarding the use of vasoactive or inotropic agents to restore or maintain flap perfusion. The purpose of this study...

  6. [Contribution of the scrotal flap for the coverage of ischial and perineal pressure ulcers].

    Science.gov (United States)

    Vantomme, M; Viard, R; Aimard, R; Vincent, P-L; Comparin, J-P; Voulliaume, D

    2018-04-11

    The ischiatric pressure sore is a common pathology in rehabilitated spinal cord injured people, despite careful prevention. Medical treatment by discharge and directed healing is not always sufficient and surgery using local musculocutaneous flaps is often essential. Unfortunately, recidivism is frequent and the availability of local flaps is limited. The scrotal flap is an excellent complement to classic flaps, gluteal flaps or hamstrings. It can be used alone or in addition to another musculocutaneous flap, in first or second intention. The scrotal flap is a musculocutaneous flap, using the Dartos, the platys muscle of the scrotum. It is richly vascularized, extensible and resistant. Its great plasticity makes it adaptable to any form of loss of substance, with an arc of rotation that can reach the anal margin. It can also be desepidermized and buried to fill a deep defect. Ten cases of scrotal flaps and their different indications are reviewed: some are used in first intention, others in addition to musculocutaneous flaps. The removal of a scrotal flap is fast and extremely easy. The simple closure of the donor site allows the sampling of half of the scrotum due to the great local laxity. The scrotal flaps achieved quickly healed, as well as the donor sites. Only one recurrence was observed after an inappropriate treatment of underlying osteitis. No complications have occurred. The scrotal musculocutaneous flap, reliable, resistant, quick and easy to remove is an excellent means of coverage of the perineal region. It can be used for the treatment of any loss of perineal substance in humans, but remains particularly useful for the treatment of ischial or perineal pressure sores. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  7. Sudden shrinkage of free rectus abdominis musculocutaneous flap 15 years after maxilla reconstruction

    Directory of Open Access Journals (Sweden)

    Yasushi Mochizuki

    2018-03-01

    Full Text Available A 60-year-old male displayed sudden shrinkage of a left free rectus abdominis musculocutaneous flap, which had been grafted to his left maxilla 15 years previously. No post-reconstructive irradiation had been performed, and no late occlusion of the vascular anastomosis, local infection, recurrence of the maxillary cancer, or body weight loss was observed. However, the shrinkage amounted to approximately 50%. This is considerably more than previously reported cases of shrinkage of various free flaps, which ranged between 10% and 25%. The resultant depression was successfully augmented with a right free deep inferior epigastric artery perforator flap. The residual fat volume of the previously grafted shrunken flap was revealed to be compatible with that of the newly harvested contralateral perforator flap. Thus, the volume of the previously grafted flap may reflect the status of the intact contralateral donor site, although the mechanism of sudden flap shrinkage is unclear.

  8. A histopathological study of bulbar conjunctival flaps occurring in 2 contact lens wearers.

    Science.gov (United States)

    Markoulli, Maria; Francis, Ian C; Yong, Jim; Jalbert, Isabelle; Carnt, Nicole; Cole, Nerida; Papas, Eric

    2011-09-01

    To study the histopathology of paralimbal bulbar conjunctival flaps occurring secondary to soft contact lens wear. Slit-lamp biomicroscopy using sodium fluorescein, cobalt blue light, and a Wratten filter was used to observe the presence, location, and dimensions of bulbar conjunctival flaps presenting in a cohort of contact lens wearers. Two subjects who exhibited such flaps agreed to undergo conjunctival biopsy. Tissue samples, obtained from the region of the flap, and an adjacent unaffected area were processed by standard histopathological methods. In the first subject, analysis of the flap tissue showed even collagen distribution and overall normal histology. The flap of the second subject displayed a mild focal increase in collagen and mild degeneration of collagen, but no increase in elastic tissue. Conjunctival epithelium was normal in both cases. In these 2 subjects, conjunctival flap tissue either was normal or showed only minimal abnormality. There is insufficient evidence for significant pathological change on the time scale of this study.

  9. Versatility of radial forearm free flap for intraoral reconstruction

    Directory of Open Access Journals (Sweden)

    Jeremić Jelena V.

    2015-01-01

    Full Text Available Introduction. The radial forearm free flap has an important role in reconstruction of the oncologic defects in the region of head and neck. Objective. The aim was to present and evaluate clinical experience and results in the radial forearm free transfer for intraoral reconstructions after resections due to malignancies. Methods. This article illustrates the versatility and reliability of forearm single donor site in 21 patients with a variety of intraoral oncologic defects who underwent immediate (19 patients, 90.5% or delayed (2 patients, 9.5% reconstruction using free flaps from the radial forearm. Fascio-cutaneous flaps were used in patients with floor of the mouth (6 cases, buccal mucosa (5 cases, lip (1 case and a retromolar triangle (2 cases defects, or after hemiglossectomy (7 cases. In addition, the palmaris longus tendon was included with the flap in 2 patients that required oral sphincter reconstruction. Results. An overall success rate was 90.5%. Flap failures were detected in two (9.5% patients, in one patient due to late ischemic necrosis, which appeared one week after the surgery, and in another patient due to venous congestion, which could not be salvaged after immediate re-exploration. Two patients required re-exploration due to vein thrombosis. The donor site healed uneventfully in all patients, except one, who had partial loss of skin graft. Conclusion. The radial forearm free flap is, due to multiple advantages, an acceptable method for reconstructions after resection of intraoral malignancies. [Projekat Ministarstva nauke Republike Srbije, br. 41006

  10. Use of various free flaps in progressive hemifacial atrophy.

    Science.gov (United States)

    Baek, Rongmin; Heo, Chanyeong; Kim, Baek-kyu

    2011-11-01

    Romberg disease is an uncommon condition manifested by progressive hemifacial atrophy of the skin, soft tissue, and bone. Facial asymmetry with soft tissue deficiency in Romberg disease causes a significant disability affecting the social life and can bring about many psychological problems. The aim of surgical treatment is cosmetic amelioration of the defect. Several conventional reconstructive procedures have been used for correcting facial asymmetry. They include fat injections, dermal fat grafts, filler injections, cartilage and bone grafts, and pedicled and free flaps. We report our experiences with 11 patients involving 11 free flaps with a minimum 1-year follow-up. All patients were classified as having moderate to severe atrophy. The average age at disease onset was 4.5 years; the average duration of atrophy was 5.2 years. No patients were operated on with a quiescent interval of less than 1 year. The average age at operation was 20.1 years, ranging from 10 to 55 years. Reconstruction was performed using 4 groin dermofat free flaps, 4 latissimus dorsi muscle free flaps, and 3 other perforator flaps. To achieve the finest symmetrical and aesthetic results, several ancillary procedures were performed in 4 patients. These procedures included Le Fort I leveling osteotomy, sagittal split ramus osteotomy, reduction malarplasty and angle plasty, rib and calvarial bone graft, correction of alopecia, and additional fat graft. All patients were satisfied with the results. We believe that a free flap transfer is the requisite treatment modality for severe degree of facial asymmetry in Romberg disease.

  11. Extended Islanded Reverse Sural Artery Flap for Staged Reconstruction of Foot Defects Proximal to Toes

    International Nuclear Information System (INIS)

    Yousaf, M.A.; Abidin, Z.U.; Khalid, K.; Haq, A.U.; Tarar, F.A.; Asif, M.U.; Tarar, M.N.

    2018-01-01

    To assess the outcome of extended delayed reverse sural artery flap for reconstruction of foot defects proximal to toes in terms of flap survival, complication and extended area. Study Design:Case series. Place and Duration of Study:Jinnah Burn and Reconstructive Surgery Centre, Lahore, from February 2015 to April 2017. Methodology:Cases who underwent delayed sural artery flap were inducted. Preoperative hand-held doppler was done to confirm the location of perforator. Two suitable perforators were chosen to raise the extended flap by crossing the proximal limit in all cases. The pedicle was kept minimum 3 cm wide and perfusion was assessed. Flap was delayed for one week and vaccum-assisted closure (VAC) dressing was applied over wound. The second surgery was performed after one week. Proximal perforator was clamped and ligated after checking adequate perfusion of flap. Flap was insetted into defect. Results:Thirty-two patients were reconstructed with delayed reverse sural artery flap. The mean age of the patients was 26.5 +12.2 years. Twenty-four (75%) patients were males and 8 (25%) were females. Twenty-two (68.7%) cases were degloving wounds after road traffic accidents (RTA), 6 (18.7%) were diabetic foot wounds, 4 (12.5%) sustained injury after falling from height and 7 (21.8%) patients had fracture of metatarsals. Twenty-eight flaps were transferred after one week delay, and only in 4 cases, flap were transferred after two weeks. All flaps survived completely. Complications of infection noted in 3 (9.3%) flaps, 3 (9.3%) flaps showed tip necrosis, 2 (6.2%) flaps undergone epidermolysis and only 2 (6.2%) showed venous congestion. Conclusion:Delayed islanded reverse sural artery perforator flap is a reliable and versatile option for resurfacing soft tissue defects of lower limb proximal to the toes with lesser complications and extended coverage area. (author)

  12. Extended Islanded Reverse Sural Artery flap for Staged Reconstruction of Foot Defects Proximal to Toes.

    Science.gov (United States)

    Yousaf, Muhammad Amin; Abidin, Zain Ul; Khalid, Kamran; Haq, Ata Ul; Khalid, Farrukh Aslam; Tarar, Faraz Ahmad; Asif, Muhammad Umar; Tarar, Moazzam Nazeer

    2018-02-01

    Obective:To assess the outcome of extended delayed reverse sural artery flap for reconstruction of foot defects proximal to toes in terms of flap survival, complication and extended area. Case series. Jinnah Burn and Reconstructive Surgery Centre, Lahore, from February 2015 to April 2017. Cases who underwent delayed sural artery flap were inducted. Preoperative hand-held doppler was done to confirm the location of perforator. Two suitable perforators were chosen to raise the extended flap by crossing the proximal limit in all cases. The pedicle was kept minimum 3 cm wide and perfusion was assessed. Flap was delayed for one week and vaccum-assisted closure (VAC) dressing was applied over wound. The second surgery was performed after one week. Proximal perforator was clamped and ligated after checking adequate perfusion of flap. Flap was insetted into defect. Thirty-two patients were reconstructed with delayed reverse sural artery flap. The mean age of the patients was 26.5 12.2 years. Twenty-four (75%) patients were males and 8 (25%) were females. Twenty-two (68.7%) cases were degloving wounds after road traffic accidents (RTA), 6 (18.7%) were diabetic foot wounds, 4 (12.5%) sustained injury after falling from height and 7 (21.8%) patients had fracture of metatarsals. Twenty-eight flaps were transferred after one week delay, and only in 4 cases, flap were transferred after two weeks. All flaps survived completely. Complications of infection noted in 3 (9.3%) flaps, 3 (9.3%) flaps showed tip necrosis, 2 (6.2%) flaps undergone epidermolysis and only 2 (6.2%) showed venous congestion. Delayed islanded reverse sural artery perforator flap is a reliable and versatile option for resurfacing soft tissue defects of lower limb proximal to the toes with lesser complications and extended coverage area.

  13. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p < 0.05), intra- or peri-flap air collection > 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery.

  14. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    International Nuclear Information System (INIS)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon

    2017-01-01

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery

  15. Vertical Profunda Artery Perforator Flap for Plantar Foot Wound Closure: A New Application.

    Science.gov (United States)

    Alfonso, Allyson R; Mayo, James L; Sharma, Vishal K; Allen, Robert J; Chiu, Ernest S

    2018-02-01

    Plantar foot reconstruction requires special consideration of both form and function. There are several fasciocutaneous flap options, each with indications and reservations. This case presents a new application of the vertical profunda artery perforator flap for definitive closure of a neuropathic foot ulcer in a young woman with spina bifida. The postoperative course was uneventful, and the flap survived completely. The surgical and donor sites were without wound recurrence at 5-month follow-up. Understanding the variability of foot flap options is important because of unique cases such as the one presented where the wound was caused by specific and less commonly observed foot anatomy. The specific choice to use the vertical profunda artery perforator flap for this patient and her neuropathic wound type was made based on its excellent flexibility, durability, and donor site appeal. The vertical profunda artery perforator flap has adequate surface area and bulk and a favorable pedicle length and caliber, can be thinned, and leaves a donor scar in a less conspicuous area than other popular free flaps for lower-extremity reconstruction. For these reasons, it should be considered a first-line therapy for free flap coverage of selected foot wounds.

  16. An abdominal tuberculosis case mimicking an abdominal mass

    African Journals Online (AJOL)

    An abdominal tuberculosis case mimicking an abdominal mass. Derya Erdog˘ an a. , Yasemin Ta ¸scı Yıldız b. , Esin Cengiz Bodurog˘lu c and Naciye Go¨nu¨l Tanır d. Abdominal tuberculosis is rare in childhood. It may be difficult to diagnose as it mimics various disorders. We present a 12-year-old child with an unusual ...

  17. Free Flap Reconstruction Monitoring Techniques and Frequency in the Era of Restricted Resident Work Hours.

    Science.gov (United States)

    Patel, Urjeet A; Hernandez, David; Shnayder, Yelizaveta; Wax, Mark K; Hanasono, Matthew M; Hornig, Joshua; Ghanem, Tamer A; Old, Matthew; Jackson, Ryan S; Ledgerwood, Levi G; Pipkorn, Patrik; Lin, Lawrence; Ong, Adrian; Greene, Joshua B; Bekeny, James; Yiu, Yin; Noureldine, Salem; Li, David X; Fontanarosa, Joel; Greenbaum, Evan; Richmon, Jeremy D

    2017-08-01

    Free flap reconstruction of the head and neck is routinely performed with success rates around 94% to 99% at most institutions. Despite experience and meticulous technique, there is a small but recognized risk of partial or total flap loss in the postoperative setting. Historically, most microvascular surgeons involve resident house staff in flap monitoring protocols, and programs relied heavily on in-house resident physicians to assure timely intervention for compromised flaps. In 2003, the Accreditation Council for Graduate Medical Education mandated the reduction in the hours a resident could work within a given week. At many institutions this new era of restricted resident duty hours reshaped the protocols used for flap monitoring to adapt to a system with reduced resident labor. To characterize various techniques and frequencies of free flap monitoring by nurses and resident physicians; and to determine if adapted resident monitoring frequency is associated with flap compromise and outcome. This multi-institutional retrospective review included patients undergoing free flap reconstruction to the head and/or neck between January 2005 and January 2015. Consecutive patients were included from different academic institutions or tertiary referral centers to reflect evolving practices. Technique, frequency, and personnel for flap monitoring; flap complications; and flap success. Overall, 1085 patients (343 women [32%] and 742 men [78%]) from 9 institutions were included. Most patients were placed in the intensive care unit postoperatively (n = 790 [73%]), while the remaining were placed in intermediate care (n = 201 [19%]) or in the surgical ward (n = 94 [7%]). Nurses monitored flaps every hour (q1h) for all patients. Frequency of resident monitoring varied, with 635 patients monitored every 4 hours (q4h), 146 monitored every 8 hours (q8h), and 304 monitored every 12 hours (q12h). Monitoring techniques included physical examination (n = 949 [87

  18. Reconstruction of the anterior floor of the mouth with the inferiorly based nasolabial flap

    NARCIS (Netherlands)

    van Wijk, MP; Damen, A; Nauta, JM; Lichtendahl, DHE; Dhar, BK

    The results of reconstruction of the anterior floor of the mouth, using 105 nasolabial flaps in 79 patients were reviewed in a retrospective study. Of those flaps, 82% healed uneventfully; flap survival was 95%. Considerable flap loss occurred in 5%. Primary dehiscence was observed in 5% of all

  19. The transverse musculo-cutaneous gracilis flap for breast reconstruction: How to avoid complications.

    Science.gov (United States)

    Bodin, Frédéric; Dissaux, Caroline; Dupret-Bories, Agnes; Schohn, Thomas; Fiquet, Caroline; Bruant-Rodier, Catherine

    2016-01-01

    The transverse musculocutaneous gracilis (TMG) flap has become a common solution for breast reconstruction. However, the safe skin paddle limits are not yet understood. In this study, we attempted to address this issue based on our experiences with inferior and posterior skin paddle extension. Forty-four breast reconstructions with TMG flaps performed between November 2010 and January 2014 were analyzed retrospectively. For the first 20 cases, the flap skin paddle was extended 3 cm posteriorly to the middle thigh (group 1). For the next 20 flaps (group 2), the posterior tip was limited to this line, whereas more fat was recruited inferiorly. In the four cases of group 3, the skin flap was extended posteriorly with a second vascular pedicle from the profunda artery perforator (PAP) flap. The weights and the dimensions of the flaps, operating durations, and postoperative complications of the entire series were analyzed. Groups 1 and 2 were statistically compared. Flap complications were statistically more frequent in group 1 compared with group 2 (45 vs. 0%, P = 0.0012); 40% posterior flap tip necrosis was observed in group 1. Conversely, donor site complications were statistically more frequent in group 2 than in group 1 (40 vs. 5%, P = 0.019) with 35% inner thigh dehiscence. In the TMG with extended PAP flap group, the operating duration was 77 min longer compared with the rest of the series with no donor site complications. In one case, limited necrosis occurred at the anterior skin tip. Harvesting the posterior portion of the TMG up to the middle of the posterior thigh may lead to partial flap necrosis. Extending subcutaneous fat removal under the inferior skin incision may increase the risk of donor site complications. Adding a second vascular pedicle from the PAP flap may improve posterior TMG tip perfusion at the expense of a longer operation. © 2015 Wiley Periodicals, Inc.

  20. Experimental validation of a true-scale morphing flap for large civil aircraft applications

    Science.gov (United States)

    Pecora, R.; Amoroso, F.; Arena, M.; Noviello, M. C.; Rea, F.

    2017-04-01

    Within the framework of the JTI-Clean Sky (CS) project, and during the first phase of the Low Noise Configuration Domain of the Green Regional Aircraft - Integrated Technological Demonstration (GRA-ITD, the preliminary design and technological demonstration of a novel wing flap architecture were addressed. Research activities were carried out to substantiate the feasibility of morphing concepts enabling flap camber variation in compliance with the demanding safety requirements applicable to the next generation green regional aircraft, 130- seats with open rotor configuration. The driving motivation for the investigation on such a technology was found in the opportunity to replace a conventional double slotted flap with a single slotted camber-morphing flap assuring similar high lift performances -in terms of maximum attainable lift coefficient and stall angle- while lowering emitted noise and system complexity. Studies and tests were limited to a portion of the flap element obtained by slicing the actual flap geometry with two cutting planes distant 0.8 meters along the wing span. Further activities were then addressed in order to increase the TRL of the validated architecture within the second phase of the CS-GRA. Relying upon the already assessed concept, an innovative and more advanced flap device was designed in order to enable two different morphing modes on the basis of the A/C flight condition / flap setting: Mode1, Overall camber morphing to enhance high-lift performances during take-off and landing (flap deployed); Mode2, Tab-like morphing mode. Upwards and downwards deflection of the flap tip during cruise (flap stowed) for load control at high speed. A true-scale segment of the outer wing flap (4 meters span with a mean chord of 0.9 meters) was selected as investigation domain for the new architecture in order to duly face the challenges posed by real wing installation. Advanced and innovative solutions for the adaptive structure, actuation and control

  1. Generating an Engineered Adipose Tissue Flap Using an External Suspension Device.

    Science.gov (United States)

    Wan, Jinlin; Dong, Ziqing; Lei, Chen; Lu, Feng

    2016-07-01

    The tissue-engineering chamber technique can generate large volumes of adipose tissue, which provides a potential solution for the complex reconstruction of large soft-tissue defects. However, major drawbacks of this technique are the foreign-body reaction and the volume limitation imposed by the chamber. In this study, the authors developed a novel tissue-engineering method using a specially designed external suspension device that generates an optimized volume of adipose flap and avoids the implantation of foreign material. The rabbits were processed using two different tissue-engineering methods, the external suspension device technique and the traditional tissue-engineering chamber technique. The adipose flaps generated by the external suspension device had a normal adipose tissue structure that was as good as that generated by the traditional tissue-engineering chamber, but the flap volume was much larger. The final volume of the engineered adipose flap grew between weeks 0 and 36 from 5.1 ml to 30.7 ml in the traditional tissue-engineering chamber group and to 80.5 ml in the external suspension device group. During the generation process, there were no marked differences between the two methods in terms of structural and cellular changes of the flap, except that the flaps in the traditional tissue-engineering chamber group had a thicker capsule at the early stage. In addition, the enlarged flaps generated by the external suspension device could be reshaped into specific shapes by the implant chamber. This minimally invasive external suspension device technique can generate large-volume adipose flaps. Combined with a reshaping method, this technique should facilitate clinical application of adipose tissue engineering.

  2. Human exonuclease 1 (EXO1) activity characterization and its function on FLAP structures

    DEFF Research Database (Denmark)

    Keijzers, Guido; Bohr, Vilhelm A; Juel Rasmussen, Lene

    2015-01-01

    structures, we determined factors essential for the thermodynamic stability of EXO1. We show that enzymatic activity and stability of EXO1 on DNA is modulated by temperature. By characterization of EXO1 flap activity using various DNA flap substrates, we show that EXO1 has a strong capacity for degrading...... double stranded DNA and has a modest endonuclease or 5' flap activity. Furthermore, we report novel mechanistic insights into the processing of flap structures, showing that EXO1 preferentially cleaves one nucleotide inwards in a double stranded region of a forked and nicked DNA flap substrates...

  3. Possibility of management of lower leg war burns with free flaps

    Directory of Open Access Journals (Sweden)

    Panajotović Ljubomir

    2003-01-01

    Full Text Available Free flaps are used in the surgical treatment of burns for wound closure where the burn is too deep, and in case, when after necrotic tissue excision, the bones, tendons, nerves, and blood vessels remain bare. Covering of the exposed structures is commonly performed in the primary delayed, or in the secondary wound treatment. The possibilities of covering the defects of the lower leg with local flaps are limited. Free flaps are used when all the possibilities of the other reconstructive procedures have been exhausted. The defect of the soft tissue of the lower leg was covered with free flaps in the injured soldiers with deep burns, treated at the Clinic for Plastic Surgery and Burns, Military Medical Academy, Belgrade. In one patient the wound closing was performed immediately after excision of necrotic tissues, and in the other two in the secondary management. The application of free microvascular flaps enabled the closure of large post excision defects of the lower leg in one operation. Our experience in the treatment of these soldiers point to the possibility of coverage of the exposed deep structures with free flaps as early as possible.

  4. Treatment of ischial pressure sores using a modified gracilis myofasciocutaneous flap.

    Science.gov (United States)

    Lin, Haodong; Hou, Chunlin; Chen, Aimin; Xu, Zhen

    2010-04-01

    Despite the availability of a variety of flap reconstruction options, ischial pressure sores continue to be the most difficult pressure sores to treat. This article describes a successful surgical procedure for the coverage of ischial ulcers using a modified gracilis myofasciocutaneous flap. From August 2000 to April 2004, 12 patients with ischial sores were enrolled in the study. All patients underwent early aggressive surgical debridement followed by surgical reconstruction with a modified gracilis myofasciocutaneous flap. The follow-up period ranged from 13 to 86 months, with a mean of 44 months. Overall, 91.7% of the flaps (11 of 12) survived primarily. Partial flap necrosis occurred in one patient. Primary wound healing occurred without complications at both the donor and recipient sites in all cases. In one patient, grade II ischial pressure sores recurred 13 months after the operation. There was no recurrence in other 11 patients. A modified gracilis myofasciocutaneous flap provides a good cover for ischial pressure sores. Because it is easy to use and has favorable results, it can be used in the primary treatment for large and deep ischial pressure sores. Copyright Thieme Medical Publishers.

  5. Improving esthetic results in benign parotid surgery: statistical evaluation of facelift approach, sternocleidomastoid flap, and superficial musculoaponeurotic system flap application.

    Science.gov (United States)

    Bianchi, Bernardo; Ferri, Andrea; Ferrari, Silvano; Copelli, Chiara; Sesenna, Enrico

    2011-04-01

    The purpose of this article was to analyze the efficacy of facelift incision, sternocleidomastoid muscle flap, and superficial musculoaponeurotic system flap for improving the esthetic results in patients undergoing partial parotidectomy for benign parotid tumor resection. The usefulness of partial parotidectomy is discussed, and a statistical evaluation of the esthetic results was performed. From January 1, 1996, to January 1, 2007, 274 patients treated for benign parotid tumors were studied. Of these, 172 underwent partial parotidectomy. The 172 patients were divided into 4 groups: partial parotidectomy with classic or modified Blair incision without reconstruction (group 1), partial parotidectomy with facelift incision and without reconstruction (group 2), partial parotidectomy with facelift incision associated with sternocleidomastoid muscle flap (group 3), and partial parotidectomy with facelift incision associated with superficial musculoaponeurotic system flap (group 4). Patients were considered, after a follow-up of at least 18 months, for functional and esthetic evaluation. The functional outcome was assessed considering the facial nerve function, Frey syndrome, and recurrence. The esthetic evaluation was performed by inviting the patients and a blind panel of 1 surgeon and 2 secretaries of the department to give a score of 1 to 10 to assess the final cosmetic outcome. The statistical analysis was finally performed using the Mann-Whitney U test for nonparametric data to compare the different group results. P less than .05 was considered significant. No recurrence developed in any of the 4 groups or in any of the 274 patients during the follow-up period. The statistical analysis, comparing group 1 and the other groups, revealed a highly significant statistical difference (P esthetic results in benign parotid surgery. The evaluation of functional complications and the recurrence rate in this series of patients has confirmed that this technique can be safely

  6. RECONSTRUCTION OF FACIAL SKIN DEFECT BY VARIOUS FLAPS : OUR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    Atishkumar B.

    2015-08-01

    Full Text Available INTRODUCTION : Face represents complete personality of human being. Cosmetically it is very important part of a person especially for woman. There are many situations when due to disease or trauma, facial defect arises, which requires reconstruction by either local or distant surgical flaps . METHODS AND MATERIALS : In rural places, we come across many patients suffering from trauma and skin malignancy of face. These patients require reconstruction done esthetically with local flaps. Objective of this study is to share our exper ience of providing esthetically good results at our secondary referral care center. Hereby, we present case series of 14 patients operated at our institute. These patients were analyzed according to the age, sex, nature of injury and anatomical location of lesion on the face. All these patients were operated and reconstruction of defect was done with various local flaps best suited for respective lesion, under local anesthesia or sedation. Post - operative nature of wound was analyzed for flap viability or fl ap necrosis . RESULTS : Amongst them were 7 male and 7 female, ages ranging from 4 to 80 years. 7out of 14 patients were of basal cell carcinoma, 4 were due to trauma, 2 were due to dog bite and 1 case of recurrent pleomorphic adenoma at root of nose. All patients had excellent flap viability at end of 6 months and flap achieving almost similar color and contour as that of surrounding skin. CONCLUSION : Reconstruction of facial defects by local flaps is very easy and cost effective technique. This can be don e even at secondary referral care centre with minimal availability of facilities

  7. Push-pull optical pumping of pure superposition states

    International Nuclear Information System (INIS)

    Jau, Y.-Y.; Miron, E.; Post, A.B.; Kuzma, N.N.; Happer, W.

    2004-01-01

    A new optical pumping method, 'push-pull pumping', can produce very nearly pure, coherent superposition states between the initial and the final sublevels of the important field-independent 0-0 clock resonance of alkali-metal atoms. The key requirement for push-pull pumping is the use of D1 resonant light which alternates between left and right circular polarization at the Bohr frequency of the state. The new pumping method works for a wide range of conditions, including atomic beams with almost no collisions, and atoms in buffer gases with pressures of many atmospheres

  8. 14 mrad Extraction Line Optics for Push-Pull

    International Nuclear Information System (INIS)

    Nosochkov, Y.; Moffeit, K.; Seryi, A.; Morse, W.; Parker, B.

    2007-01-01

    The ILC design is based on a single Interaction Region (IR) with 14 mrad crossing angle and two detectors in the 'push-pull' configuration, where the detectors can alternately occupy the Interaction Point (IP). Consequently, the IR optics must be compatible with different size detectors designed for different distance L* between the IP and the nearest quadrupole. This paper presents the push-pull optics for the ILC extraction line compatible with L*= 3.5 m to 4.5 m, and the simulation results of extraction beam loss at 500 GeV CM with detector solenoid

  9. Double papilla flap technique for dual purpose

    Directory of Open Access Journals (Sweden)

    P Mohan Kumar

    2012-01-01

    Full Text Available Marginal tissue recession exposes the anatomic root on the teeth, which gives rise to -common patient complaints. It is associated with sensitivity, tissue irritation, cervical abrasions, and esthetic concerns. Various types of soft tissue grafts may be performed when recession is deep and marginal tissue health cannot be maintained. Double papilla flap is an alternative technique to cover isolated recessions and correct gingival defects in areas of insufficient attached gingiva, not suitable for a lateral sliding flap. This technique offers the advantages of dual blood supply and denudation of interdental bone only, which is less susceptible to permanent damage after surgical exposure. It also offers the advantage of quicker healing in the donor site and reduces the risk of facial bone height loss. This case report presents the advantages of double papilla flap in enhancing esthetic and functional outcome of the patient.

  10. Modelling the behaviour of the push-pull gel dosimeter

    International Nuclear Information System (INIS)

    Bosi, S.G.; Davies, J.B.; Gorjiara, T.; Baldock, C.

    2010-01-01

    Full text: Recent development of a gel dosimeter based on the radiobleaching pigment, genipin, allows development of a new 3D optically scanned gel dosimeter-the p ush-pull g el. This gel would contain two spectrally complementary pigments, one which darkens with dose and another (e.g. genipin) which bleaches. The two pigments deal separately with the high and low dose ends of the dosimeter's dynamic range. The bleaching pigment would be optimised for high sensitivity and the darkening pigment for low. Employing dual pigments, optimised independently, relaxes the need for compromise between sensitivity at low dose and accuracy at high dose. Such a gel, after exposure, would be read using two successive optical CT scans, at two different wavelengths. The reduction in sensitivity of the darkening pigment (allowed by the use of push-pull) would reduce the occurrence of regions of high optical attenuation which can generate optical CT artefacts. Simulated optical CT reconstructions of the optical density map (Fig. La) scanned at the darkening pigment wavelength of a hypothetical push-pull gel, confirms the reduction in susceptibility to artefacts. Fig. I b shows a profile through the map with no stray light added. The centre of the profile in Fig. I d shows a cupping artefact produced by 10 ppm of stray light. The similarity of Fig. Ic and b show that a 30% sensitivity reduction allowed by push-pull, renders the artefact negligible. This paper presents the results of' these simulations of a push-pull gel scanned using optical CT and also some results of experiments with genipin gel. (author)

  11. Modeling of Airfoil Trailing Edge Flap with Immersed Boundary Method

    DEFF Research Database (Denmark)

    Zhu, Wei Jun; Shen, Wen Zhong; Sørensen, Jens Nørkær

    2011-01-01

    The present work considers incompressible flow over a 2D airfoil with a deformable trailing edge. The aerodynamic characteristics of an airfoil with a trailing edge flap is numerically investigated using computational fluid dynamics. A novel hybrid immersed boundary (IB) technique is applied...... to simulate the moving part of the trailing edge. Over the main fixed part of the airfoil the Navier-Stokes (NS) equations are solved using a standard body-fitted finite volume technique whereas the moving trailing edge flap is simulated with the immersed boundary method on a curvilinear mesh. The obtained...... results show that the hybrid approach is an efficient and accurate method for solving turbulent flows past airfoils with a trailing edge flap and flow control using trailing edge flap is an efficient way to regulate the aerodynamic loading on airfoils....

  12. Model predictive control of trailing edge flaps on a wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Castaignet, D.B.

    2011-11-15

    Trailing edge flaps on wind turbine blades have been investigated for several years. Aero-servoelastic simulations carried out with different simulation tools, trailing edge flaps configurations and controller designs proved that trailing edge flaps are a suitable solution for reducing some of the wind turbine fatigue and extreme loads. This potential was confirmed with wind tunnel tests made on blade sections with trailing edge flaps and on a scaled two-bladed wind turbine in a wind tunnel. The work presented in this thesis includes a full-scale test run on a Vestas V27 wind turbine equipped with three trailing edge flaps on one blade, located on DTU's Risoe Campus in Roskilde, Denmark. This thesis is divided into three parts: the controller design, results from simulations, and results from the experiments. The trailing edge flaps controller designed for this project is based on a frequency-weighted model predictive control, tuned in order to target only the flapwise blade root loads at the frequencies contributing the most to blade root fatigue damage (the 1P, 2P and 3P frequencies), and to avoid unnecessary wear and tear of the actuators at high frequencies. A disturbance model consisting in periodic disturbances at the rotor speed harmonic frequencies and a quasi-steady input disturbance is aggregated to an analytical model of a spinning blade with trailing edge flaps. Simulations on a multi-megawatt wind turbine show the potential of the trailing edge flaps to reduce the flapwise blade root fatigue loads by 23%, but also the main shaft and the tower fatigue loads by up to 32%. Extreme loads during normal production also benefit from the trailing edge flaps. At last, the same controller was run on the Vestas V27 wind turbine located at the Risoe Campus of the Technical University of Denmark, in Roskilde, Denmark. One blade of the turbine was equipped with three independent trailing edge flaps. In spite of the failure of several sensors and actuators, the

  13. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  14. Free toe pulp flap for finger pulp and volar defect reconstruction

    Directory of Open Access Journals (Sweden)

    Jyoshid R Balan

    2016-01-01

    Full Text Available Background: Fingertip injury requiring flap cover is very common in the modern era. The ideal cover should fulfill both functional and aesthetic improvement. Materials and Methods: From June 2015 to April 2016, we performed seven free toe pulp flaps for finger defect reconstruction. All patients were males. Five flaps were done in emergency post-traumatic cases, and two were done in elective set up. The cases included reconstruction of three thumbs, one index and one ring finger in an emergency set up and two ring fingers in the elective. Thumb reconstruction was done with great toe lateral pulp and the other digits reconstructed with second toe pulp flap. Follow-up evaluation included both functional and aesthetic assessment. Results: Five flaps survived completely, one suffered partial loss, and one flap failed completely. The median follow-up period was 9 months. The median duration of surgery was 255 min (range 210 to 300 min. The median two-point discrimination was 6.5 mm (range 4–8 mm. There was the return of temperature sensation in all patients; two had cold intolerance. The Semmes-Weinstein monofilament score varied from 3.61 to 5.07 (median filament index value 4.31/pressure value of 2 g/mm2. Three patients had delayed donor site wound healing. Conclusions: The free toe pulp flap is an efficient choice for fingertip and volar finger defects reconstruction with an excellent tissue match.

  15. Propeller flaps for lower-limb trauma | Rogers | South African ...

    African Journals Online (AJOL)

    The propeller flap has become a versatile and important component in our reconstructive algorithm following complex lower limb trauma. First described by Hyakusoku in 1991, it has since been adapted and modified by Hallock and Teo. This article outlines our experience specifically with perforator pedicled propeller flaps ...

  16. Free vascularized flaps for reconstruction of the mandible: complications, success, and dental rehabilitation.

    Science.gov (United States)

    van Gemert, Johannes T M; van Es, Robert J J; Rosenberg, Antoine J W P; van der Bilt, Andries; Koole, Ron; Van Cann, Ellen M

    2012-07-01

    To evaluate complications and success of mandibular reconstruction with free fibula flaps, iliac crest flaps, and forearm flaps with reconstruction plates and to evaluate dental rehabilitation after these reconstructions. Eighty-three patients with segmental mandibular defects were included. Correlation analyses were used to determine the relationship between reconstruction type and clinical parameters with recipient-site complications and success. The dental rehabilitation was evaluated in successfully reconstructed survivors. Multivariate analyses showed significant correlations between flap type and success (P < .0001). Of the patients, 51 (61%) were alive 2 years after the reconstruction. Mandibular reconstruction with a free forearm flap and reconstruction plate was associated with higher complication rates at the recipient site and higher failure rates compared with reconstruction with free vascularized bone flaps. Of the 32 successfully reconstructed survivors, 14 (44%) had a complete dental rehabilitation, of which 10 had dental implants and 4 did not. Only 6 (29%) of the edentulous survivors ultimately had an implant-supported prosthesis. Reconstruction of the mandible with a free vascularized bone flap is superior to reconstruction with a free forearm flap with a reconstruction plate. Complete dental rehabilitation was reached in fewer than half of the surviving patients. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Intra-abdominal hypertension and abdominal compartment syndrome in association with ruptured abdominal aortic aneurysm in the endovascular era: vigilance remains critical.

    Science.gov (United States)

    Bozeman, Matthew C; Ross, Charles B

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  18. Wake Measurement Downstream of a Hybrid Wing Body Model with Blown Flaps

    Science.gov (United States)

    Lin, John C.; Jones, Gregory S.; Allan, Brian G.; Westra, Bryan W.; Collins, Scott W.; Zeune, Cale H.

    2010-01-01

    Flow-field measurements were obtained in the wake of a full-span Hybrid Wing Body model with internally blown flaps. The test was performed at the NASA Langley 14 x 22 Foot Subsonic Tunnel at low speeds. Off-body measurements were obtained with a 7-hole probe rake survey system. Three model configurations were investigated. At 0deg angle of attack the surveys were completed with 0deg and 60deg flap deflections. At 10deg angle of attack the wake surveys were completed with a slat and a 60deg flap deflection. The 7-hole probe results further quantified two known swirling regions (downstream of the outboard flap edge and the inboard/outboard flap juncture) for the 60deg flap cases with blowing. Flowfield results and the general trends are very similar for the two blowing cases at nozzle pressure ratios of 1.37 and 1.56. High downwash velocities correlated with the enhanced lift for the 60deg flap cases with blowing. Jet-induced effects are the largest at the most inboard station for all (three) velocity components due in part to the larger inboard slot height. The experimental data are being used to improve computational tools for high-lift wings with integrated powered-lift technologies.

  19. Management of a Traumatic Flap Dislocation Seven Years after LASIK

    Directory of Open Access Journals (Sweden)

    Majid Moshirfar

    2011-01-01

    Full Text Available Seven years after uneventful laser in situ keratomileusis (LASIK, a 48-year-old woman presented one week after being hit with an iron cord with blurry vision, pain, and irritation. The injury resulted in traumatic flap dislocation, epithelial ingrowth, and macrostriae. Following epithelial removal, the flap was refloated and repositioned. Nine interrupted sutures were used to secure the flap. Three-weeks after surgery with no sutures remaining, the epithelial ingrowth and macrostriae had resolved with a visual acuity of 20/20.

  20. The use of free musculocutaneous flaps to cover chronic radiation ulcers

    International Nuclear Information System (INIS)

    Tsujiguchi, Kounosuke; Tajima, Sadao; Tanaka, Yoshio; Hira, Michiya; Imai, Keisuke; Fukae, Eiichi; Omiya, Yuka.

    1992-01-01

    Three patients with chronic radiation ulcer treated with free musculocutaneous flap transfer are described. The first patient was a 66-year-old woman who developed sacral ulcer 7 years after radiation combined with surgery for uterine cancer. After debridement of this ulcer, interpositional vein grafts 30 cm in length was used to reconstruct an 'extended' latissimus dorsi musculocutaneous flap. The second patient was a 62-year-old woman. She developed ulcer on her chest 15 years after postoperative irradiation for breast cancer. Radiation damage extended to the myocardium and pulmonary parenchyma. After careful debridement, reconstruction was performed by using the free rectus abdominis musculocutaneous flap. The last patient was a 72-year-old woman. Ulcer of the right axilla developed 19 years after postoperative irradiation for breast cancer. Reconstruction was performed by using a free rectus abdominis musculocutaneous flap. In these patients in whom radiation-damaged tissue was not completely excised, favorable results could be attained by using the transfer of the free musculocutaneous flaps. (N.K.)

  1. Expanded flap to repair facial scar left by radiotherapy of hemangioma.

    Science.gov (United States)

    Zhao, Donghong; Ma, Xinrong; Li, Jiang; Zhang, Lingfeng; Zhu, Baozhen

    2014-09-01

    This study explored the feasibility and clinical efficacy of expanded flap to repair facial scar left by radiotherapy of hemangioma. From March 2000 to April 2011, 13 cases of facial cicatrices left by radiotherapy of hemangioma have been treated with implantation surgery of facial skin dilator under local anesthesia. After water flood expansion for 1-2 months, resection of facial scar was performed, and wound repairing with expansion flap transfer was done. Thirteen patients were followed up from 5 months to 3 years. All patients tolerated flap transfer well; no contracture occurred during the facial expansion flap transfer. The incision scar was not obvious, and its color and texture were identical to surrounding skin. In conclusion, the use of expanded flap transfer to repair the facial scar left by radiotherapy of hemangioma is advantageous due to its simplicity, flexibility, and large area of repairing. This method does not affect the subsequent facial appearance.

  2. Effect of Reynolds Number on Aerodynamics of Airfoil with Gurney Flap

    Directory of Open Access Journals (Sweden)

    Shubham Jain

    2015-01-01

    Full Text Available Steady state, two-dimensional computational investigations performed on NACA 0012 airfoil to analyze the effect of variation in Reynolds number on the aerodynamics of the airfoil without and with a Gurney flap of height of 3% chord are presented in this paper. RANS based one-equation Spalart-Allmaras model is used for the computations. Both lift and drag coefficients increase with Gurney flap compared to those without Gurney flap at all Reynolds numbers at all angles of attack. The zero lift angle of attack seems to become more negative as Reynolds number increases due to effective increase of the airfoil camber. However the stall angle of attack decreased by 2° for the airfoil with Gurney flap. Lift coefficient decreases rapidly and drag coefficient increases rapidly when Reynolds number is decreased below critical range. This occurs due to change in flow pattern near Gurney flap at low Reynolds numbers.

  3. The effect of topical minoxidil pretreatment on nonsurgical delay of rat cutaneous flaps: further studies.

    Science.gov (United States)

    Gümüş, Nazım; Odemiş, Yusuf; Tuncer, Ersin; Yılmaz, Sarper

    2013-08-01

    The purpose of this study was to determine the effectiveness of topically applied minoxidil in the pharmacological delay phenomenon and to demonstrate the comparable microscopic and macroscopic changes between minoxidil-pretreated flaps and surgically delayed flaps. A modified version of the McFarlane flap was used. Group 1 rats, in which a caudally based dorsal skin flap was raised and sutured back, were the control group. In group II, minoxidil solution was spread over the marked skin flap area for 7 days. On the 7th day, a caudally based dorsal skin flap was elevated and then sutured back. Group III rats underwent a surgical delay procedure alone. On the 7th day after flap elevation, evaluation was done by histologic examination and calculation of the flap survival areas in all groups. The lowest flap survival rate appeared in group I and was statistically different from groups II and III. The mean surviving skin flap area in the minoxidil-pretreated group was significantly larger than that in the control group. After histologic evaluation, moderate angiogenesis was also detected in group II. We also found that surgical delay significantly reduced flap necrosis when compared to the minoxidil pretreatment group. According to our study, minoxidil may be considered an effective vasoactive agent for the stimulation of angiogenesis in rat cutaneous flaps and capable of achieving pharmacological delay and increasing flap survival. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Saphenous vein grafts for perforator flap salvage in autologous breast reconstruction.

    Science.gov (United States)

    Flores, Jaime I; Rad, Ariel N; Shridharani, Sachin M; Stapleton, Sahael M; Rosson, Gedge D

    2009-01-01

    Although the use of saphenous vein grafts in free-flap salvage and extremity replantation is relatively common, their use in breast reconstruction is rare. These two case reports represent extreme alternatives for breast reconstruction flap salvage. In our normal daily practice, the overwhelming majority of elective breast reconstructions proceed smoothly. However, the occasional patient may require saphenous vein graft flap rescue for completion of the reconstruction. (c) 2008 Wiley-Liss, Inc.

  5. Microsurgical free flap reconstructions of head and neck region in 406 cases: a 13-year experience.

    Science.gov (United States)

    Gerressen, Marcus; Pastaschek, Claudia Inge; Riediger, Dieter; Hilgers, Ralf-Dieter; Hölzle, Frank; Noroozi, Nelson; Ghassemi, Alireza

    2013-03-01

    The reconstruction of extended soft tissue and bony defects in the maxillofacial region with microsurgical flaps is considered to be the therapy of first choice. The aim of this retrospective study was to detect different influencing factors concerning flap survival. We examined the data of 406 patient cases (121 female and 285 male cases; mean age, 57 years) undergoing reconstruction with a microsurgical flap in our facility between 1998 and 2010. In these cases 326 soft tissue flaps (radial forearm flap, scapula flap, latissimus dorsi flap, anterolateral thigh flap, lateral arm flap, and jejunum flap) and 80 bony flaps (fibula flap and deep circumflex iliac artery flap) were examined. Evaluated parameters were, among others, the timing of reconstruction, defect localization, and recipient vessels used (external vs internal jugular system), as well as anticoagulative management. We statistically analyzed data by means of a χ(2) test, taking account of the odds ratio with P < .05, which was deemed significant. The overall flap survival rate was approximately 92%, without any gender- or age-specific differences. Primary reconstructions proceeded distinctly more successfully than secondary reconstructions (P < .01). Likewise, the defect localization exerted a significant effect on the survival rate (P = .01), with a more caudal localization affecting flap survival positively. Finally, neither the anticoagulation regimen nor the choice of recipient vein system exercised an influence on the survival rate. Microsurgical tissue transfer is a convenient and reliable method in maxillofacial surgery, provided that one is aware of the determining factors for success. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Increased Flap Weight and Decreased Perforator Number Predict Fat Necrosis in DIEP Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Carolyn L. Mulvey, BS

    2013-05-01

    Conclusions: Flaps with increasing weight have increased risk of fat necrosis. These data suggest that inclusion of more than 1 perforator may decrease odds of fat necrosis in large flaps. Perforator flap breast reconstruction can be performed safely; however, considerations concerning race, body mass index, staging with tissue expanders, perforator number, and flap weight may optimize outcomes.

  7. The management of pelvic pressure ulcers by myocutaneous flaps ...

    African Journals Online (AJOL)

    Pressure ulcers or ischaemic necrosis of tissues over bony eminences due to pressure, heal very slowly. Vascularised tissues such as myocutaneous flaps are necessary to cover the ulcer and accelerate healing. This study was done to share our experience with methods of myocutaneous flaps in the treatment of pressure ...

  8. Scrotal Reconstruction with a Pedicled Gracilis Muscle Flap after ...

    African Journals Online (AJOL)

    Several scrotal reconstructive options are available including split thickness skin grafts, scrotal advancement flaps, local fasciocutaneous, muscle or myocutaneous flaps, and free tissue transfer. We report a case of a 34 year old African male who presented as a referral from a district hospital with a scrotal defect and ...

  9. Abdominal trauma

    International Nuclear Information System (INIS)

    Giordany, B.R.

    1985-01-01

    Abdominal injury is an important cause of morbidity and mortality in childhood. Ten percent of trauma-related deaths are due to abdominal injury. Thousands of children are involved in auto accidents annually; many suffer severe internal injury. Child abuse is a second less frequent but equally serious cause of internal abdominal injury. The descriptions of McCort and Eisenstein and their associates in the 1960s first brought to attention the frequency and severity of visceral injury as important manifestations of the child abuse syndrome. Blunt abdominal trauma often causes multiple injuries; in the past, many children have been subjected to exploratory surgery to evaluate the extent of possible hidden injury. Since the advent of noninvasive radiologic imaging techniques including radionuclide scans and ultrasound and, especially, computed tomography (CT), the radiologist has been better able to assess (accurately) the extent of abdominal injury and thus allow conservative therapy in many cases. Penetrating abdominal trauma occurs following gunshot wounds, stabbing, and other similar injury. This is fortunately, a relatively uncommon occurrence in most pediatric centers and will not be discussed specifically here, although many principles of blunt trauma diagnosis are valid for evaluation of penetrating abdominal trauma. If there is any question that a wound has extended intraperitonelly, a sinogram with water-soluble contrast material allows quick, accurate diagnosis. The presence of large amounts of free intraperitoneal gas suggests penetrating injury to the colon or other gas-containing viscus and is generally considered an indication for surgery

  10. Effect of intradermal human recombinant copper-zinc superoxide dismutase on random pattern flaps in rats.

    Science.gov (United States)

    Schein, Ophir; Westreich, Melvyn; Shalom, Avshalom

    2013-09-01

    Studies have focused on enhancing flap viability using superoxide dismutase (SOD), but only a few used SOD from human origin, and most gave the compound systemically. We evaluated the ability of SOD to improve random skin flap survival using human recombinant copper-zinc superoxide dismutase (Hr-CuZnSOD) in variable doses, injected intradermally into the flap. Seventy male Sprague Dawley rats were randomly assigned into 4 groups. Cephalic random pattern flaps were elevated on their backs and intradermal injections of different dosages of Hr-CuZnSOD were given 15 minutes before surgery. Flap survival was evaluated by fluorescein fluorescence. Analysis of variance (ANOVA) and t test statistical analyses were performed. Flap survival in all treated groups was significantly better than in the controls. The beneficial effect of HR-CuZnSOD on flap survival is attained when it is given intradermally into the flap tissue. Theoretically, Hr-CuZnSOD delivered with local anesthetics used in flap elevation may be a valuable clinical tool. Copyright © 2012 Wiley Periodicals, Inc.

  11. RANS Simulations of Aerodynamic Performance of NACA 0015 Flapped Airfoil

    Directory of Open Access Journals (Sweden)

    Sohaib Obeid

    2017-01-01

    Full Text Available An analysis of 2D subsonic flow over an NACA 0015 airfoil with a 30% trailing edge flap at a constant Reynolds number of 106 for various incidence angles and a range of flap deflections is presented. The steady-state governing equations of continuity and momentum conservation are solved combined with the realizable k-ε turbulence model using the ANSYS-Fluent code (Version 13.7, ANSYS, Inc., Canonsburg, PA, USA. The primary objective of the study is to provide a comprehensive understanding of flow characteristics around the NACA 0015 airfoil as a function of the angle of attack and flap deflection at Re = 106 using the realizable k-ε turbulence model. The results are validated through comparison of the predictions with the free field experimental measurements. Consistent with the experimental observations, the numerical results show that increased flap deflections increase the maximum lift coefficient, move the zero-lift angle of attack (AoA to a more negative value, decrease the stall AoA, while the slope of the lift curve remains unchanged and the curve just shifts upwards. In addition, the numerical simulations provide limits for lift increment Δ C l and Cl, max values to be 1.1 and 2.2, respectively, obtained at a flap deflection of 50°. This investigation demonstrates that the realizable k-ε turbulence model is capable of predicting flow features over an airfoil with and without flap deflections with reasonable accuracy.

  12. Anatomical Basis and Clinical Application of Synovial Flaps in the Wrist and Distal Forearm.

    Science.gov (United States)

    Colen, David L; Yeh, Jiun-Ting; Colen, Lawrence B

    2017-05-01

    Neuropathic symptoms after median nerve repair at the wrist or secondary to refractory carpal tunnel syndrome may become debilitating. These symptoms develop because of perineural adhesions, intraneural fibrosis, and fixation of the nerve to the transverse carpal ligament after surgery, and often require neurolysis. Interposition of vascularized soft tissue over the median nerve at the time of neurolysis prevents recurrence of such adhesions. The synovial flap, fashioned from the synovial lining of the flexor tendon sheath, is an ideal tissue for this purpose. Previous authors have described the surgical technique of the synovial flap, but the anatomical basis and design of the flap have not been previously discussed. Twenty fresh cadaver upper extremities were injected with Microfil to analyze the arterial anatomy, flap dimensions, and arc of rotation of the flexor tendon synovium mobilized as a flap suitable for coverage of the median nerve at the wrist. The authors determined that both radial and ulnar-based flaps are clinically useful for providing coverage in the wrist and distal forearm. This flap was used in 18 patients with complicated median nerve lesions in this region. All patients had an uncomplicated postoperative course. Of 13 patients treated for posttraumatic median nerve neuromas, all but two had significant resolution of symptoms. When used as a vascularized flap, the flexor tendon synovium provides adequate protection of the median nerve. Flap dimensions and vascularity of this tissue make it an ideal local flap option when performing reoperative surgery on the median nerve.

  13. Effect of vitrification on number of inner cell mass in mouse blastocysts in conventional straw, closed pulled straw, open pulled straw and cryoloop carriers

    International Nuclear Information System (INIS)

    Ghasem, S.; Negar, K.

    2013-01-01

    Objective: To compare the effect of using open and closed carriers on count of inner cell mass in vitrified mouse blastocyst after warming. Methods: The experimental study was conducted at Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, from April to September 2010. Forty female NMRI (Naval Medical Research Institute, USA) mice were injected with pregnant mares serum gonadotropin and human chorionic gonadotropin in order to induce super ovulation. Following the latter injection, two or three females were caged with the same-breed male mice. The presence of vaginal plug was examined the following morning. To collect blastocyst embryos, the pregnant females were sacrificed by cervical dislocation at 88-90 hours after the injection and dissected. Blastocysts were collected in phosphate-buffered saline and allocated to four groups: vitrification in conventional straw, closed pulled straw, open pulled straw and cryoloop. The vitrification solution was ethylene glycol, Ficol and sucrose (EFS) 20% and 40%. After storage for 1 month in liquid nitrogen, the blastocysts were thawed in 0.5 M sucrose then cultured in M16 medium. After 6 hours of culture, the number of expanded blastocysts was recorded and stained by double-dye technique. After staining, the number of total cell and inner cell mass was calculated. Results: The re-expansion rate of blastocysts in the cryoloop group (n=90; 78.26%) was significantly higher (p<0.05) than open pulled straw (n=83; 69.16%), closed pulled straw (n=68; 54.83%) and conventional straws (n=63; 51.21%) groups. Significant differences (p<0.05) in the number of inner cell mass in blastocysts vitrified in open pulled straws, closed straws and cryoloop with blastocysts cryopreserved in conventional straws. Conclusion: The re-expansion rate and total cell number of mouse blastocysts vitrified using open system had a better result compared with the closed system. The value of cryoloop and open pulled straws as carriers in

  14. Flapping-wing mechanical butterfly on a wheel

    Science.gov (United States)

    Godoy-Diana, Ramiro; Thiria, Benjamin; Pradal, Daniel

    2009-11-01

    We examine the propulsive performance of a flapping-wing device turning on a ``merry-go-round'' type base. The two-wing flapper is attached to a mast that is ball-bearing mounted to a central shaft in such a way that the thrust force produced by the wings makes the flapper turn around this shaft. The oscillating lift force produced by the flapping wings is aligned with the mast to avoid vibration of the system. A turning contact allows to power the motor that drives the wings. We measure power consumption and cruising speed as a function of flapping frequency and amplitude as well as wing flexibility. The design of the wings permits to change independently their flexibility in the span-wise and chord-wise directions and PIV measurements in various planes let us examine the vorticity field around the device. A complete study of the effect of wing flexibility on the propulsive performance of the system will be presented at the conference.

  15. [Clinical application of modified upper gluteal rhomboid fasciocutaneous flap in repairing sacrococcygeal pressure sores].

    Science.gov (United States)

    Jiang, Maohua; Yang, Xiaoliang; Wei, Bangmin; Li, Yinghao

    2012-03-01

    To investigate the method and effectiveness of repairing sacrococcygeal pressure sores with modified upper gluteal rhomboid fasciocutaneous flap. Between January 2004 and March 2011, 43 patients with sacrococcygeal pressure sores were treated. There were 25 males and 18 females with an average age of 63 years (range, 38-95 years). The disease duration was 3 months to 2 years and 6 months (mean, 8.5 months). The size of pressure sores ranged from 6 cm x 5 cm to 18 cm x 13 cm. According to the extent and lesion degree of pressure scores, 23 pressure sores were rated as degree III and 20 pressure sores as degree IV. The modified upper gluteal rhomboid flap was designed, one-side upper gluteal fasciocutaneous flaps were transplanted to repair sacrococcygeal pressure sores in 19 cases and two-side flaps in 24 cases. The size of one side flap ranged from 6.5 cm x 4.5 cm to 18.0 cm x 11.5 cm. Fluid under flap occurred in 1 case and edge necrosis of the flaps in 3 cases at 7 days after operation, which were cured after drainage and dressing change; the other flaps survived, and incisions healed by first intention. All patients were followed up 6 months to 3 years with an average of 11 months. Two patients relapsed at 5 months and 8 months, respectively; the other patients had no recurrence. The color of the flaps was normal, and the appearance and elasticity of the flaps were good. The modified upper gluteal rhomboid fasciocutaneous flap has the advantages of simple design and operation, less injury, and reliable effect in repairing sacrococcygeal pressure sores.

  16. Danish experience with free flaps in war wounds

    DEFF Research Database (Denmark)

    Holmgaard, Rikke; Duffy, Jonas; Warburg, Finn Edgar

    2016-01-01

    of 11). Flap-loss occurred in one patient, presumably due to leakage at the anastomotic site, which necessitated another free flap procedure. All patients received rehabilitation services following discharge from the inpatient unit, including prosthetic fitting. The mean follow-up time was 26 months....... CONCLUSIONS: This report is the first to detail the reconstructive procedures in soldiers treated at a public hospital in Denmark. The treatment of war casualties has not only been a challenge to the surgeons tasked with managing these devastating injuries, but also to Danish healthcare in general....... The outcome of multidisciplinary treatment, combining the expertise of various specialties, is highly encouraging. The rate of complications was low, and the aesthetic appearance of the reconstructed limbs and the functional recovery were satisfactory. We therefore recommend the use of free flaps...

  17. Detached Eddy Simulation of Flap Side-Edge Flow

    Science.gov (United States)

    Balakrishnan, Shankar K.; Shariff, Karim R.

    2016-01-01

    Detached Eddy Simulation (DES) of flap side-edge flow was performed with a wing and half-span flap configuration used in previous experimental and numerical studies. The focus of the study is the unsteady flow features responsible for the production of far-field noise. The simulation was performed at a Reynolds number (based on the main wing chord) of 3.7 million. Reynolds Averaged Navier-Stokes (RANS) simulations were performed as a precursor to the DES. The results of these precursor simulations match previous experimental and RANS results closely. Although the present DES simulations have not reached statistical stationary yet, some unsteady features of the developing flap side-edge flowfield are presented. In the final paper it is expected that statistically stationary results will be presented including comparisons of surface pressure spectra with experimental data.

  18. Mechanism of oil-pulling therapy - in vitro study.

    Science.gov (United States)

    Asokan, Sharath; Rathinasamy, T K; Inbamani, N; Menon, Thangam; Kumar, S Senthil; Emmadi, Pamela; Raghuraman, R

    2011-01-01

    Oil pulling has been used extensively as a traditional Indian folk remedy without scientific proof for many years for strengthening teeth, gums and jaws and to prevent decay, oral malodor, bleeding gums and dryness of throat and cracked lips. The aim of this study was to evaluate the antibacterial activity of sesame oil and lignans isolated from sesame oil on oral microorganisms and to check whether saponification or emulsification occurs during oil-pulling therapy. The in vitro study was carried out in three different phases: (1) Antibacterial activity of the lignans and sesame oil were tested by minimum inhibitory concentration assay by agar dilution method and agar well diffusion method, respectively. (2) Increase in free fatty acid level of oil and the quantity of sodium hydroxide (NaOH) used up in the titration are good indicators of saponification process. This was assessed using analytical tests for vegetable oils. (3) Swished oil was observed under light microscope to assess the status of the oil, presence of microorganisms, oral debris and foreign bodies. Sesamin and sesamolin isolated from sesame oil did not have any antibacterial effect against oral microorganisms like Streptococcus mutans, Streptococcus mitis and Streptococcus viridans. Emulsification of sesame oil occurs during oil-pulling therapy. Increased consumption of NaOH in titration is a definite indication of a possible saponification process. The myth that the effect of oil-pulling therapy on oral health was just a placebo effect has been broken and there are clear indications of possible saponification and emulsification process, which enhances its mechanical cleaning action.

  19. Duodenal Obstruction after Elective Abdominal Aortic Aneurysm Repair: A Case Report

    Directory of Open Access Journals (Sweden)

    Chun-Yao Lin

    2004-10-01

    Full Text Available Gastrointestinal tract complications after abdominal aortic aneurysm (AAA repair are well known. The reported frequency ranges from 6.6% to 21%. However, the incidence of duodenal obstruction following AAA has probably been underestimated. This report concerns a 78-year-old male who was admitted for elective repair of an infrarenal AAA. On the ninth postoperative day, the patient presented with large quantities of bile-stained vomitus despite passing flatus per rectum. Metoclopramide and ranitidine were given under the initial impression of paralytic ileus. However, the upper gastrointestinal obstruction persisted, and on day 12, computerized tomography (CT revealed marked distension of the gastric tube and duodenum, down to the level of the third portion, with abrupt change of caliber at the point of the superior mesenteric artery (SMA. SMA syndrome was diagnosed. After nasogastric tube aspiration, parenteral nutrition, and 11 days of conservative treatment, abdominal CT and upper gastrointestinal series showed no apparent duodenal obstruction. The patient was discharged on the 29th postoperative day; follow-up abdominal CT 4 months later was unremarkable.

  20. Push and pull strategies: applications for health care marketing.

    Science.gov (United States)

    Kingsley, B R

    1987-08-01

    As health care markets mature and expand, strategies available in other industries become useful. This article examines how traditional push-pull strategies apply to health care. Marketers using a push strategy recognize that the sale of their services or goods is dependent upon the endorsement of a middleman and promote their product through the middleman. Those using a pull strategy market directly to the consumer. In this article, the author outlines the advantages and disadvantages of using each strategy.