WorldWideScience

Sample records for providing release time

  1. Disestablishing Sex: The Case for Released-Time Sex Education

    Science.gov (United States)

    Glanzer, Perry L.

    2011-01-01

    Allowing nonschool organizations to provide sex education in a released-time format would disestablish state-funded sex education and give families a choice in the sex education that would be provided for their children. Released-time programs, as originally conceived and currently practiced, allow students to be released for a period of time…

  2. 49 CFR 236.790 - Release, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Release, time. 236.790 Section 236.790... Release, time. A device used to prevent the operation of an operative unit until after the expiration of a predetermined time interval after the device has been actuated. ...

  3. Modified-release hydrocortisone to provide circadian cortisol profiles.

    Science.gov (United States)

    Debono, Miguel; Ghobadi, Cyrus; Rostami-Hodjegan, Amin; Huatan, Hiep; Campbell, Michael J; Newell-Price, John; Darzy, Ken; Merke, Deborah P; Arlt, Wiebke; Ross, Richard J

    2009-05-01

    Cortisol has a distinct circadian rhythm regulated by the brain's central pacemaker. Loss of this rhythm is associated with metabolic abnormalities, fatigue, and poor quality of life. Conventional glucocorticoid replacement cannot replicate this rhythm. Our objectives were to define key variables of physiological cortisol rhythm, and by pharmacokinetic modeling test whether modified-release hydrocortisone (MR-HC) can provide circadian cortisol profiles. The study was performed at a Clinical Research Facility. Using data from a cross-sectional study in healthy reference subjects (n = 33), we defined parameters for the cortisol rhythm. We then tested MR-HC against immediate-release hydrocortisone in healthy volunteers (n = 28) in an open-label, randomized, single-dose, cross-over study. We compared profiles with physiological cortisol levels, and modeled an optimal treatment regimen. The key variables in the physiological cortisol profile included: peak 15.5 microg/dl (95% reference range 11.7-20.6), acrophase 0832 h (95% confidence interval 0759-0905), nadir less than 2 microg/dl (95% reference range 1.5-2.5), time of nadir 0018 h (95% confidence interval 2339-0058), and quiescent phase (below the mesor) 1943-0531 h. MR-HC 15 mg demonstrated delayed and sustained release with a mean (sem) maximum observed concentration of 16.6 (1.4) microg/dl at 7.41 (0.57) h after drug. Bioavailability of MR-HC 5, 10, and 15 mg was 100, 79, and 86% that of immediate-release hydrocortisone. Modeling suggested that MR-HC 15-20 mg at 2300 h and 10 mg at 0700 h could reproduce physiological cortisol levels. By defining circadian rhythms and using modern formulation technology, it is possible to allow a more physiological circadian replacement of cortisol.

  4. An oral multiparticulate, modified-release, hydrocortisone replacement therapy that provides physiological cortisol exposure.

    Science.gov (United States)

    Whitaker, Martin; Debono, Miguel; Huatan, Hiep; Merke, Deborah; Arlt, Wiebke; Ross, Richard J

    2014-04-01

    It is not possible with current hydrocortisone replacement to mimic the diurnal cortisol profile in patients with adrenal insufficiency. Previous attempts with modified-release technology were unsuccessful. Our objective was to develop hydrocortisone formulations that recreate the diurnal cortisol profile using multiparticulate technology. Screening by in vitro dissolution profiles, pharmacokinetic (PK) testing in dexamethasone-suppressed dogs and humans, and comparison with a reference population. Field laboratories and clinical research facility. Formulations were generated using an enteric (delayed release) design configuration with an extended (sustained release) dissolution profile. In vitro dissolution confirmed delayed and sustained hydrocortisone release. However, in dogs and humans, sustained release resulted in reduced bioavailability. A formulation, DIURF-006, was developed that maintained delayed release but omitted the sustained-release functionality. PK characterization of DIURF-006 showed that, despite absence of a sustained-release component, absorption was sufficiently sustained to deliver extended hydrocortisone absorption. In dexamethasone-suppressed volunteers (n = 16) receiving a twice-daily 'toothbrush' regimen (20 mg at 23:00 h and 10 mg at 07:00 h), DIURF-006 gave a similar cortisol profile to physiological cortisol levels: DIURF-006 vs physiological, Geomean AUC 5610 vs 4706 h * nmol/l, Geomean Cmax 665 vs 594 nmol/l and Median Tmax 8·5 h vs clock time 08:12 h for peak cortisol. The relative bioavailability of DIURF-006 vs hydrocortisone was 89%, and cortisol levels increased linearly with doses between 5 and 30 mg. A multiparticulate oral hydrocortisone formulation with only an enteric coat provides delayed and sustained absorption and when given in a 'toothbrush' regimen provides physiological cortisol exposure. © 2013 John Wiley & Sons Ltd.

  5. An oral multi-particulate, modified release, hydrocortisone replacement therapy that provides physiological cortisol exposure

    Science.gov (United States)

    Huatan, Hiep; Merke, Deborah; Arlt, Wiebke; Ross, Richard J.

    2013-01-01

    Objective It is not possible with current hydrocortisone replacement to mimic the diurnal cortisol profile in patients with adrenal insufficiency. Previous attempts with modified release technology were unsuccessful. Our objective was to develop hydrocortisone formulations that recreate the diurnal cortisol profile using multi-particulate technology. Design and Measurements Screening by in-vitro dissolution profiles, pharmacokinetic testing in dexamethasone suppressed dogs and humans, and comparison to a reference population. Setting Field laboratories and clinical research facility. Results Formulations were generated using an enteric (delayed-release) design configuration with an extended (sustained-release) dissolution profile. In-vitro dissolution confirmed delayed and sustained hydrocortisone release. However, in dogs and humans, sustained release resulted in reduced bioavailability. A formulation, DIURF-006, was developed that maintained delayed release but omitted the sustained release functionality. Pharmacokinetic characterisation of DIURF-006 showed that, despite absence of a sustained release component, absorption was sufficiently sustained to deliver extended hydrocortisone absorption. In dexamethasone-suppressed volunteers (n=16) receiving a twice daily ‘toothbrush’ regimen (20mg at 23:00h and 10mg at 07:00h), DIURF-006 gave a similar cortisol profile to physiological cortisol levels: DIURF-006 vs physiological, Geomean AUC 5610 vs 4706 hr*nmol/l, Geomean Cmax 665 vs 594 nmol/l and Median Tmax 8.5h vs clock time 08:12 hours for peak cortisol. The relative bioavailability of DIURF-006 vs hydrocortisone was 89% and cortisol levels increased linearly with doses between 5 and 30mg. Conclusion A multi-particulate oral hydrocortisone formulation with only an enteric coat provides delayed and sustained absorption and when given in a ‘toothbrush’ regimen provides physiological cortisol exposure. PMID:23980724

  6. Implementation of Releasing Time to Care - the productive ward.

    Science.gov (United States)

    Wilson, Gwyneth

    2009-07-01

    This paper describes the implementation of the NHS Institute for Innovation and Improvement Productive Ward - releasing time to care programme. It will discuss the benefits and key successes and provides advice for those wishing to implement the programme. In Lord Darzi's Next Stage Review, he advocates an ambitious vision of patient centred - clinician led, locally driven NHS. The Releasing Time to Care programme is a unique opportunity for everyone working within the NHS to improve effectiveness, safety and reliability of the services we provide. Whilst being situated within a National Health Service policy environment learning from this work can be translated nationally and internationally, as the principles underpin the provision of high quality care. Evaluation is currently in relation to each of the 15 modules rather than as the programme as a whole. It uses various methods including audit, observation, activity follow through, satisfaction surveys and process mapping. Each month data is colated for each of the 11 metrics which has shown a reduction in falls, drug administration errors and improvement in the recording of patient observations. One of the key issues is that an essential component for the success of the programme lies in the tangible support of the Trust Board/Board of Directors. Evidence shows that this programme improves patient satisfaction as it enables the provision of an increase in direct patient care by staff and subsequently improved clinical and safety outcomes. Ward Sister/Charge Nurse development includes Leadership, Project management and Lean Methodology techniques. The Releasing Time to Care programme is a key component of the Next Stage Review. It will create productive organisations by being a catalyst for the transformation of Trust services, enabling staff to spend more time caring for patients and users. This release in time will result in better outcomes and subsequent improvement with patient and staff satisfaction and

  7. Timing crisis information release via television.

    Science.gov (United States)

    Wei, Jiuchang; Zhao, Dingtao; Yang, Feng; Du, Shaofu; Marinova, Dora

    2010-10-01

    When and how often to release information on television are important issues in crisis and emergency risk communication. There is a lot of crisis information, including warnings and news, to which people should have access, but most of it is not significantly urgent to interrupt the broadcasting of television programmes. Hence, the right timing for the release of crisis information should be selected based on the importance of the crisis and any associated communication requirements. Using recursive methods, this paper builds an audience coverage model of crisis information release. Based on 2007 Household Using TV (HUT) data for Hefei City, China, the optimal combination of broadcasting sequence (with frequencies between one and eight times) is obtained using the implicit enumeration method. The developed model is applicable to effective transmission of crisis information, with the aim of reducing interference with the normal television transmission process and decreasing the psychological effect on audiences. The same model can be employed for other purposes, such as news coverage and weather and road information. © 2010 The Author(s). Journal compilation © Overseas Development Institute, 2010.

  8. A systematic literature review of Releasing Time to Care: The Productive Ward.

    Science.gov (United States)

    Wright, Stella; McSherry, Wilfred

    2013-05-01

    This systematic review provides an overview of the literature published on Releasing Time to Care: The Productive Ward between 2005 and June 2011. Releasing Time to Care: The Productive Ward programme was developed by the NHS Institute for Innovation and Improvement and launched in England in 2007. The programme comprises thirteen modules that aim to increase time for direct patient care, improve the patient and staff experience and make changes to the ward environment to improve efficiency. A systematic literature review. The terms 'Releasing Time to Care' and 'Productive Ward' were applied to key healthcare databases; CINAHL, Medline, Science Direct, ProQuest, Health Business Elite, British Nursing Index, Embase, Health Management Information Consortium and PsychInfo. All papers were read and subject to a quality assessment. The literature search identified 95 unique sources. A lack of research on The Productive Ward programme meant it was necessary to include non-empirical literature. In total, 18 articles met the inclusion criteria. Seven key themes were identified: the patient and staff experience, direct care time, patient safety, financial impact, embedding and sustainability, executive support and leadership, and common barriers and determinants of success. It also highlighted areas that require further exploration such as long-term sustainability of the programme and consistent data measurement between organisations. The review tentatively reports how The Productive Ward programme has been used to transform nursing practice for the benefit of patients and frontline staff, and how it resulted in cost savings. The literature review identified a potential positive results bias in the current literature whereby favourable outcomes were reported. This paper summarises the types of evidence and current literature on The Productive Ward providing a reference for frontline staff implementing the programme. © 2013 Blackwell Publishing Ltd.

  9. Phytantriol based liquid crystal provide sustained release of anticancer drug as a novel embolic agent.

    Science.gov (United States)

    Qin, Lingzhen; Mei, Liling; Shan, Ziyun; Huang, Ying; Pan, Xin; Li, Ge; Gu, Yukun; Wu, Chuanbin

    2016-01-01

    Phytantriol has received increasing amount of attention in drug delivery system, however, the ability of the phytantriol based liquid crystal as a novel embolic agent to provide a sustained release delivery system is yet to be comprehensively demonstrated. The purpose of this study was to prepare a phytantriol-based cubic phase precursor solution loaded with anticancer drug hydroxycamptothecine (HCPT) and evaluate its embolization properties, in vitro drug release and cytotoxicity. Phase behavior of the phytantriol-solvent-water system was investigated by visual inspection and polarized light microscopy, and no phase transition was observed in the presence of HCPT within the studied dose range. Water uptake by the phytantriol matrices was determined gravimetrically, suggesting that the swelling complied with the second order kinetics. In vitro evaluation of embolic efficacy indicated that the isotropic solution displayed a satisfactory embolization effect. In vitro drug release results showed a sustained-release up to 30 days and the release behavior was affected by the initial composition and drug loading. Moreover, the in vitro cytotoxicity and anticancer activity were evaluated by MTT assay. No appreciable mortality was observed for NIH 3T3 cells after 48 h exposure to blank formulations, and the anticancer activity of HCPT-loaded formulations to HepG2 and SMMC7721 cells was strongly dependent on the drug loading and treatment time. Taken together, these results indicate that phytantriol-based cubic phase embolic gelling solution is a promising potential carrier for HCPT delivery to achieve a sustained drug release by vascular embolization, and this technology may be potential for clinical applications.

  10. Dual turn-on fluorescence signal-based controlled release system for real-time monitoring of drug release dynamics in living cells and tumor tissues.

    Science.gov (United States)

    Kong, Xiuqi; Dong, Baoli; Song, Xuezhen; Wang, Chao; Zhang, Nan; Lin, Weiying

    2018-01-01

    Controlled release systems with capabilities for direct and real-time monitoring of the release and dynamics of drugs in living systems are of great value for cancer chemotherapy. Herein, we describe a novel dual turn-on fluorescence signal-based controlled release system ( CDox ), in which the chemotherapy drug doxorubicin ( Dox ) and the fluorescent dye ( CH ) are conjugated by a hydrazone moiety, a pH-responsive cleavable linker. CDox itself shows nearly no fluorescence as the fluorescence of CH and Dox is essentially quenched by the C=N isomerization and N-N free rotation. However, when activated under acidic conditions, CDox could be hydrolyzed to afford Dox and CH , resulting in dual turn-on signals with emission peaks at 595 nm and 488 nm, respectively. Notably, CDox exhibits a desirable controlled release feature as the hydrolysis rate is limited by the steric hindrance effect from both the Dox and CH moieties. Cytotoxicity assays indicate that CDox shows much lower cytotoxicity relative to Dox , and displays higher cell inhibition rate to cancer than normal cells. With the aid of the dual turn-on fluorescence at different wavelengths, the drug release dynamics of CDox in living HepG2 and 4T-1 cells was monitored in double channels in a real-time fashion. Importantly, two-photon fluorescence imaging of CDox in living tumor tissues was also successfully performed by high-definition 3D imaging. We expect that the unique controlled release system illustrated herein could provide a powerful means to investigate modes of action of drugs, which is critical for development of much more robust and effective chemotherapy drugs.

  11. Real-time UV imaging of nicotin release from transdermal patch

    DEFF Research Database (Denmark)

    Østergaard, Jesper; Meng-Lund, Emil; Larsen, Susan Weng

    2010-01-01

    PURPOSE: This study was conducted to characterize UV imaging as a platform for performing in vitro release studies using Nicorette® nicotine patches as a model drug delivery system. METHODS: The rate of nicotine release from 2 mm diameter patch samples (Nicorette®) into 0.067 M phosphate buffer, p......H 7.40, was studied by UV imaging (Actipix SDI300 dissolution imaging system) at 254 nm. The release rates were compared to those obtained using the paddle-over-disk method. RESULTS: Calibration curves were successfully established which allowed temporally and spatially resolved quantification...... of nicotine. Release profiles obtained from UV imaging were in qualitative agreement with results from the paddle-over-disk release method. CONCLUSION: Visualization as well as quantification of nicotine concentration gradients was achieved by UV imaging in real time. UV imaging has the potential to become...

  12. Micromagnetic Cancer Cell Immobilization and Release for Real-Time Single Cell Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jaiswal, Devina; Rad, Armin Tahmasbi [Department of Biomedical Engineering, University of Connecticut, Storrs, CT, 06269 (United States); Nieh, Mu-Ping [Department of Biomedical Engineering, University of Connecticut, Storrs, CT, 06269 (United States); Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, CT 06269 (United States); Polymer Program, Institute of Materials Science, University of Connecticut, Storrs, CT 06269 (United States); Claffey, Kevin P. [Department of Cell Biology, University of Connecticut Health Center, Farmington, CT 06030 (United States); Hoshino, Kazunori, E-mail: hoshino@engr.uconn.edu [Department of Biomedical Engineering, University of Connecticut, Storrs, CT, 06269 (United States)

    2017-04-01

    Understanding the interaction of live cells with macromolecules is crucial for designing efficient therapies. Considering the functional heterogeneity found in cancer cells, real-time single cell analysis is necessary to characterize responses. In this study, we have designed and fabricated a microfluidic channel with patterned micromagnets which can temporarily immobilize the cells during analysis and release them after measurements. The microchannel is composed of plain coverslip top and bottom panels to facilitate easy microscopic observation and undisturbed application of analytes to the cells. Cells labeled with functionalized magnetic beads were immobilized in the device with an efficiency of 90.8±3.6%. Since the micromagnets are made of soft magnetic material (Ni), they released cells when external magnetic field was turned off from the channel. This allows the reuse of the channel for a new sample. As a model drug analysis, the immobilized breast cancer cells (MCF7) were exposed to fluorescent lipid nanoparticles and association and dissociation were measured through fluorescence analysis. Two concentrations of nanoparticles, 0.06 µg/ml and 0.08 µg/ml were tested and time lapse images were recorded and analyzed. The microfluidic device was able to provide a microenvironment for sample analysis, making it an efficient platform for real-time analysis.

  13. Towards more physiological manipulations of hormones in field studies: comparing the release dynamics of three kinds of testosterone implants, silastic tubing, time-release pellets and beeswax.

    Science.gov (United States)

    Quispe, Rene; Trappschuh, Monika; Gahr, Manfred; Goymann, Wolfgang

    2015-02-01

    Hormone manipulations are of increasing interest in the areas of physiological ecology and evolution, because hormones are mediators of complex phenotypic changes. Often, however, hormone manipulations in field settings follow the approaches that have been used in classical endocrinology, potentially using supra-physiological doses. To answer ecological and evolutionary questions, it may be important to manipulate hormones within their physiological range. We compare the release dynamics of three kinds of implants, silastic tubing, time-release pellets, and beeswax pellets, each containing 3mg of testosterone. These implants were placed into female Japanese quail, and plasma levels of testosterone measured over a period of 30 days. Testosterone in silastic tubing led to supraphysiological levels. Also, testosterone concentrations were highly variable between individuals. Time-release pellets led to levels of testosterone that were slightly supraphysiological during the first days. Over the period of 30 days, however, testosterone concentrations were more consistent. Beeswax implants led to a physiological increase in testosterone and a relatively constant release. The study demonstrated that hormone implants in 10mm silastic tubing led to a supraphysiological peak in female quail. Thus, the use of similar-sized or even larger silastic implants in males or in other smaller vertebrates needs careful assessment. Time-release pellets and beeswax implants provide a more controlled release and degrade within the body. Thus, it is not necessary to recapture the animal to remove the implant. We propose beeswax implants as an appropriate procedure to manipulate testosterone levels within the physiological range. Hence, such implants may be an effective alternative for field studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Time scales of solar microwave bursts and scenarios of flare enregy release

    International Nuclear Information System (INIS)

    Krueger, A.; Kliem, B.; Hildebrandt, J.

    1989-01-01

    Based on earlier observational evidence that characteristic time scales of different solar microwave burst types are distributed over a wide range (10 -3 -10 4 sec), different mechanisms of energy release have been considered to account for the impulsive flux increase (time scale 3 sec). Among different competing processes the coalescence instability is found to be a promising candidate to combine sufficiently short time scales with substantial energy release. (author). 20 refs.; 1 fig

  15. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    Directory of Open Access Journals (Sweden)

    Mingrong Zhang

    2016-05-01

    Full Text Available The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-deep waveforms were matched within reasonable accuracy. Finally, with the help of dynamic image processing, the aerosol-release time (Tr was carefully measured and fully discussed, including the switch-on time (Ts, the mechatronics-hysteresis (Tm and the intentional-delay (Ti. Under slow-deep inhalation condition which is suitable for metered dose inhaler medicine delivery, the switch-on flow-rate could reach as low as 10 L/min, and the corresponding switch-on time was approximately 0.20 s. While the mechatronics-hysteresis depended on the brand of metered dose inhaler, assuming there was no intentional-delay, the aerosol-release time could be as low as 0.40 and 0.60 s, respectively, for two commercially available metered dose inhalers studied in this article. Therefore, this newly developed mechatronic adapter system could ensure aerosol-release time (Tr within satisfactory range for metered dose inhalers.

  16. Accelerated in-vitro release testing methods for extended-release parenteral dosage forms.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-07-01

    This review highlights current methods and strategies for accelerated in-vitro drug release testing of extended-release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in-situ depot-forming systems and implants. Extended-release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, 'real-time' in-vitro release tests for these dosage forms are often run over a long time period. Accelerated in-vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in-vitro release methods using United States Pharmacopeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended-release parenteral dosage forms, along with the accelerated in-vitro release testing methods currently employed are discussed. Accelerated in-vitro release testing methods with good discriminatory ability are critical for quality control of extended-release parenteral products. Methods that can be used in the development of in-vitro-in-vivo correlation (IVIVC) are desirable; however, for complex parenteral products this may not always be achievable. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.

  17. Time-oriented experimental design method to optimize hydrophilic matrix formulations with gelation kinetics and drug release profiles.

    Science.gov (United States)

    Shin, Sangmun; Choi, Du Hyung; Truong, Nguyen Khoa Viet; Kim, Nam Ah; Chu, Kyung Rok; Jeong, Seong Hoon

    2011-04-04

    A new experimental design methodology was developed by integrating the response surface methodology and the time series modeling. The major purposes were to identify significant factors in determining swelling and release rate from matrix tablets and their relative factor levels for optimizing the experimental responses. Properties of tablet swelling and drug release were assessed with ten factors and two default factors, a hydrophilic model drug (terazosin) and magnesium stearate, and compared with target values. The selected input control factors were arranged in a mixture simplex lattice design with 21 experimental runs. The obtained optimal settings for gelation were PEO, LH-11, Syloid, and Pharmacoat with weight ratios of 215.33 (88.50%), 5.68 (2.33%), 19.27 (7.92%), and 3.04 (1.25%), respectively. The optimal settings for drug release were PEO and citric acid with weight ratios of 191.99 (78.91%) and 51.32 (21.09%), respectively. Based on the results of matrix swelling and drug release, the optimal solutions, target values, and validation experiment results over time were similar and showed consistent patterns with very small biases. The experimental design methodology could be a very promising experimental design method to obtain maximum information with limited time and resources. It could also be very useful in formulation studies by providing a systematic and reliable screening method to characterize significant factors in the sustained release matrix tablet. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Time-dependent histamine release from stored human blood products

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørgen; Edvardsen, L; Vangsgaard, K

    1996-01-01

    .0 (range 176.0-910.0) nmol/l in whole blood and 475.0 (range 360.0-1560.0) nmol/l in plasma-reduced whole blood, while it was undetectable in SAGM blood. Spontaneous histamine release increased in a time-dependent manner from a median of 6.7 (range 2.2-17.4) nmol/l at the time of storage to 175.0 (range 33...

  19. Release kinetics of tocopherol and quercetin from binary antioxidant controlled-release packaging films.

    Science.gov (United States)

    Chen, Xi; Lee, Dong Sun; Zhu, Xuntao; Yam, Kit L

    2012-04-04

    This paper investigated the feasibility of manipulating packaging polymers with various degrees of hydrophobicity to release two antioxidants, tocopherol and quercetin, at rates suitable for long-term inhibition of lipid oxidation in food. For example, one antioxidant can be released at a fast rate to provide short-term/intermediate protection, whereas the other antioxidant can be released at a slower rate to provide intermediate/long-term protection of lipid oxidation. Controlled-release packaging films containing tocopherol and quercetin were produced using ethylene vinyl alcohol (EVOH), ethylene vinyl acetate (EVA), low-density polyethylene (LDPE), and polypropylene (PP) polymers; the release of these antioxidants to 95% ethanol (a fatty food simulant) was measured using UV-vis spectrophotometry, and Fickian diffusion models with appropriate initial and boundary conditions were used to fit the data. For films containing only quercetin, the results show that the release of quercetin was much faster but lasted for a much shorter time for hydrophilic polymers (EVOH and EVA) than for hydrophobic polymers (LDPE and PP). For binary antioxidant films containing tocopherol and quercetin, the results show that tocopherol released more rapidly but for a shorter period of time than quercetin in LDPE and EVOH films, and the difference is more pronounced for LDPE films than EVOH films. The results also show the presence of tocopherol can accelerate the release of quercetin. Although none of the films produced is acceptable for long-term lipid oxidation inhibition, the study provides encouraging results suggesting that acceptable films may be produced in the future using polymer blend films.

  20. 28 CFR 571.22 - Release clothing and transportation.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Release clothing and transportation. 571... AND RELEASE RELEASE FROM CUSTODY Release Gratuities, Transportation, and Clothing § 571.22 Release clothing and transportation. (a) Staff shall provide release clothing appropriate for the time of year and...

  1. Atmospheric plume progression as a function of time and distance from the release point for radioactive isotopes.

    Science.gov (United States)

    Eslinger, Paul W; Bowyer, Ted W; Cameron, Ian M; Hayes, James C; Miley, Harry S

    2015-10-01

    The radionuclide network of the International Monitoring System comprises up to 80 stations around the world that have aerosol and xenon monitoring systems designed to detect releases of radioactive materials to the atmosphere from nuclear explosions. A rule of thumb description of plume concentration and duration versus time and distance from the release point is useful when designing and deploying new sample collection systems. This paper uses plume development from atmospheric transport modeling to provide a power-law rule describing atmospheric dilution factors as a function of distance from the release point. Consider the plume center-line concentration seen by a ground-level sampler as a function of time based on a short-duration ground-level release of a nondepositing radioactive tracer. The concentration C (Bq m(-3)) near the ground varies with distance from the source with the relationship C=R×A(D,C) ×e (-λ(-1.552+0.0405×D)) × 5.37×10(-8) × D(-2.35) where R is the release magnitude (Bq), D is the separation distance (km) from the ground level release to the measurement location, λ is the decay constant (h(-1)) for the radionuclide of interest and AD,C is an attenuation factor that depends on the length of the sample collection period. This relationship is based on the median concentration for 10 release locations with different geographic characteristics and 365 days of releases at each location, and it has an R(2) of 0.99 for 32 distances from 100 to 3000 km. In addition, 90 percent of the modeled plumes fall within approximately one order of magnitude of this curve for all distances. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Effect of Coating Solvent Ratio on the Drug Release Lag Time of ...

    African Journals Online (AJOL)

    Erah

    Research Article ... Lag Time of Coated Theophylline Osmotic Tablets ... Key words: Coating solvent, Drug release, Lag time, Osmotic tablet, HPMC, .... following composition (w/w): theophylline ... tablets was measured by UV absorption.

  3. Radiation shielding provided by residential houses in Japan in reactor accidents accompanied with atmospheric release

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro; Minami, Kentaro

    1991-01-01

    The present report describes the radiation shielding effect of houses in Japan against the radioactive cloud resulting from a major reactor accident accompanied with atmospheric release. The shielding factor of houses, the ratio of indoor exposure rate to outdoor one, has been studied for the semi-infinite and finite clouds which contain γ-emitting radionuclides released from a reactor facility. The shielding factor of houses against γ-rays from the radioactive cloud decreases gradually with release delay time and keeps a minimum during the period from 50 to 1000 hours after reactor shutdown while 133 Xe predominates in the cloud. Radioiodines mixed in the cloud raise slightly the shielding factor, and the factor depends little on the shape of the cloud. A set of shielding factors for the use of emergency planning was consequently proposed as 0.4 for simple ferroconcrete residential house and 0.9 for other ordinary ones. (author)

  4. Colon-specific pulsatile drug release provided by electrospun shellac nanocoating on hydrophilic amorphous composites.

    Science.gov (United States)

    Yang, Yao-Yao; Liu, Zhe-Peng; Yu, Deng-Guang; Wang, Ke; Liu, Ping; Chen, Xiaohong

    2018-01-01

    Colon-specific pulsatile drug release, as a combined drug controlled-release model, is a useful drug delivery manner for a series of diseases. New nanomedicines and related preparation methods are highly desired. With diclofenac sodium (DS) as a model drug, a new type of structural nanocomposite (SC), in which composite polyvinylpyrrolidone (PVP)-DS core was coated by shellac, was fabricated via modified coaxial electrospinning. For comparison, traditional PVP-DS monolithic hydrophilic nanocomposites (HCs) were generated using a traditional blending process. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), attenuated total reflectance-Fourier transform infrared (ATR-FTIR), water contact angle (WCA), and in vitro dissolution and ex vivo permeation tests were conducted to characterize the composites. SEM images demonstrated that both composites were linear nanofibers with smooth surface morphology and cross sections. TEM disclosed that the SCs had a thin shellac sheath layer of approximately 12 nm. XRD and ATR-FTIR results demonstrated that the crystalline DS was converted into amorphous composites with PVP because of favorable secondary interactions. WCA and in vitro dissolution tests demonstrated that the sheath shellac layers in SC could resist acid conditions and provide typical colon-specific pulsatile release, rather than a pulsatile release of HC under acid conditions. Ex vivo permeation results demonstrated that the SCs were able to furnish a tenfold drug permeation rate than the DS particles on the colon membrane. A new SC with a shellac coating on hydrophilic amorphous nanocomposites could furnish a colon-specific pulsatile drug release profile. The modified coaxial process can be exploited as a useful tool to create nanocoatings.

  5. Caffeinated nitric oxide-releasing lozenge improves cycling time trial performance.

    Science.gov (United States)

    Lee, J; Kim, H T; Solares, G J; Kim, K; Ding, Z; Ivy, J L

    2015-02-01

    Boosting nitric oxide production during exercise by various means has been found to improve exercise performance. We investigated the effects of a nitric oxide releasing lozenge with added caffeine (70 mg) on oxygen consumption during steady-state exercise and cycling time trial performance using a double-blinded randomized, crossover experimental design. 15 moderately trained cyclists (7 females and 8 males) were randomly assigned to ingest the caffeinated nitric oxide lozenge or placebo 5 min before exercise. Oxygen consumption and blood lactate were assessed at rest and at 50%, 65% and 75% maximal oxygen consumption. Exercise performance was assessed by time to complete a simulated 20.15 km cycling time-trial course. No significant treatment effects for oxygen consumption or blood lactate at rest or during steady-state exercise were observed. However, time-trial performance was improved by 2.1% (p<0.01) when participants consumed the nitric oxide lozenge (2,424±69 s) compared to placebo (2,476±78 s) and without a significant difference in rating of perceived exertion. These results suggest that acute supplementation with a caffeinated nitric oxide releasing lozenge may be a practical and effective means of improving aerobic exercise performance. © Georg Thieme Verlag KG Stuttgart · New York.

  6. The timing statistics of spontaneous calcium release in cardiac myocytes.

    Directory of Open Access Journals (Sweden)

    Mesfin Asfaw

    Full Text Available A variety of cardiac arrhythmias are initiated by a focal excitation that disrupts the regular beating of the heart. In some cases it is known that these excitations are due to calcium (Ca release from the sarcoplasmic reticulum (SR via propagating subcellular Ca waves. However, it is not understood what are the physiological factors that determine the timing of these excitations at both the subcellular and tissue level. In this paper we apply analytic and numerical approaches to determine the timing statistics of spontaneous Ca release (SCR in a simplified model of a cardiac myocyte. In particular, we compute the mean first passage time (MFPT to SCR, in the case where SCR is initiated by spontaneous Ca sparks, and demonstrate that this quantity exhibits either an algebraic or exponential dependence on system parameters. Based on this analysis we identify the necessary requirements so that SCR occurs on a time scale comparable to the cardiac cycle. Finally, we study how SCR is synchronized across many cells in cardiac tissue, and identify a quantitative measure that determines the relative timing of SCR in an ensemble of cells. Using this approach we identify the physiological conditions so that cell-to-cell variations in the timing of SCR is small compared to the typical duration of an SCR event. We argue further that under these conditions inward currents due to SCR can summate and generate arrhythmogenic triggered excitations in cardiac tissue.

  7. Accelerated in vitro release testing methods for extended release parenteral dosage forms

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J.

    2012-01-01

    Objectives This review highlights current methods and strategies for accelerated in vitro drug release testing of extended release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in situ depot-forming systems, and implants. Key findings Extended release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, “real-time” in vitro release tests for these dosage forms are often run over a long time period. Accelerated in vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in vitro release methods using United States Pharmacopoeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended release parenteral dosage forms, along with the accelerated in vitro release testing methods currently employed are discussed. Conclusions Accelerated in vitro release testing methods with good discriminatory ability are critical for quality control of extended release parenteral products. Methods that can be used in the development of in vitro-in vivo correlation (IVIVC) are desirable, however for complex parenteral products this may not always be achievable. PMID:22686344

  8. Reported implementation lessons from a national quality improvement initiative; Productive Ward: Releasing Time to Care™. A qualitative, ward-based team perspective.

    Science.gov (United States)

    White, Mark; Butterworth, Tony; Wells, John S G

    2017-10-01

    To explore the experiences of participants involved in the implementation of the Productive Ward: Releasing Time to Care™ initiative in Ireland, identifying key implementation lessons. A large-scale quality improvement programme Productive Ward: Releasing Time to Care™ was introduced nationwide into Ireland in 2011. We captured accounts from ward-based teams in an implementation phase during 2013-14 to explore their experiences. Semi-structured, in-depth interviews with a purposive sample of 24 members of ward-based teams from nine sites involved in the second national phase of the initiative were conducted. Interviews were analysed and coded under themes, using a seven-stage iterative process. The predominant theme identified was associated with the implementation and management of the initiative and included: project management; training; preparation; information and communication; and participant's negative experiences. The most prominent challenge reported related to other competing clinical priorities. Despite the structured approach of Productive Ward: Releasing Time to Care™, it appears that overstretched and busy clinical environments struggle to provide the right climate and context for ward-based teams to engage and interact actively with quality improvement tools, methods and activities. Findings highlight five key aspects of implementation and management that will help facilitate successful adoption of large-scale, ward-based quality improvement programmes such as Productive Ward: Releasing Time to Care™. Utilising pre-existing implementation or quality frameworks to assess each ward/unit for 'readiness' prior to commencing a quality improvement intervention such as Productive Ward: Releasing Time to Care™ should be considered. © 2017 John Wiley & Sons Ltd.

  9. Does Endoscopic Piriformis Tenotomy Provide Safe and Complete Tendon Release? A Cadaver Study.

    Science.gov (United States)

    Coulomb, Rémy; Khelifi, Anis; Bertrand, Martin; Mares, Olivier; May, Olivier; Marchand, Philippe; Kouyoumdjian, Pascal

    2018-05-28

    Endoscopic piriformis release (EPR) is among the available treatments for piriformis syndrome. This procedure typically involves dividing the muscle near the sciatic nerve in the sub-gluteal space, which contains numerous blood vessels and nerves. The objectives of this prospective cadaver study were: 1) to assess the reproducibility and quality of endoscopic piriformis tenotomy near the greater trochanter; 2) to detect iatrogenic injuries to the lateral hip rotators, nerves, and vessels; 3) and to define the surgical safety margins relative to the sciatic nerve and inferior gluteal bundle. EPR at the greater trochanter ensures full release of the muscle with a limited risk of neuro-vascular injury. EPR was performed via two portals on 10 cadaver hips preserved in zinc chloride and placed in the prone position. A third, ancillary portal was required in 7 cases. The area was then dissected with the Kocher-Langenbeck approach to allow an assessment of the tenotomy, detect iatrogenic injuries, and measure the distances separating the tenotomy site from the sciatic nerve and inferior gluteal artery. Complete tenotomy was achieved in 9 (90%) cases. The tendon adhered to the capsule in 2 (20%) cases and showed acquired avulsion in 1 case. No injuries to the sciatic nerve or inferior gluteal artery occurred. Mean distances from the tenotomy site were 5.21±0.59cm (range, 4.5-6.6cm) for the sciatic nerve and 7.1±0.89cm (range, 5.4-8.5cm) for the inferior gluteal artery. EPR by a tenotomy at the greater trochanter without sciatic nerve release provides full release of the muscle with satisfactory safety margins and a short learning curve. III, prospective cadaver case-control study. Copyright © 2018. Published by Elsevier Masson SAS.

  10. Possible chaoticity for the time series of the amount of nuclear information released by the newsmedia

    International Nuclear Information System (INIS)

    Ohnishi, T.

    1995-01-01

    The amount of information concerning nuclear problems was time analysed which has been released by three types of the newsmedia in Japan, the press, television and magazines during the past 20 years. The time series of the logarithmic value of the amount released by some of the newsmedia was found to be possibly chaotic, or at least to be non-stochastic. Such a characteristic of time series can be interpreted as a result of the exertion of a certain sort of selection process in the interior of the newsmedia in deciding an event as news to be released. (author)

  11. A REVIEW ON CONTROLLED DRUG RELEASE FORMULATION: SPANSULES

    OpenAIRE

    Rinky Maurya; Dr. Pramod Kumar Sharma; Rishabha Malviya

    2014-01-01

    Spansules are a dosage form which was considered as one of the Advanced Drug Delivery System. Multidrug preparations can be delivered easily by spansules or granules in capsule technology. This type of delivery system designed to release a drug or a medicament at two or more different rates or in different span of time. A quick/slow release system provides an initial release of drug followed by a constant rate of drug release over a extended period or a defined period of time and in slow/quic...

  12. Nonlinearities in Drug Release Process from Polymeric Microparticles: Long-Time-Scale Behaviour

    Directory of Open Access Journals (Sweden)

    Elena Simona Bacaita

    2012-01-01

    Full Text Available A theoretical model of the drug release process from polymeric microparticles (a particular type of polymer matrix, through dispersive fractal approximation of motion, is built. As a result, the drug release process takes place through cnoidal oscillations modes of a normalized concentration field. This indicates that, in the case of long-time-scale evolutions, the drug particles assemble in a lattice of nonlinear oscillators occur macroscopically, through variations of drug concentration. The model is validated by experimental results.

  13. SU-F-19A-08: Optimal Time Release Schedule of In-Situ Drug Release During Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Cormack, R; Ngwa, W; Makrigiorgos, G; Tangutoori, S; Rajiv, K; Sridhar, S

    2014-01-01

    Purpose: Permanent prostate brachytherapy spacers can be used to deliver sustained doses of radiosentitizing drug directly to the target, in order to enhance the radiation effect. Implantable nanoplatforms for chemo-radiation therapy (INCeRTs) have a maximum drug capacity and can be engineered to control the drug release schedule. The optimal schedule for sensitization during continuous low dose rate irradiation is unknown. This work studies the optimal release schedule of drug for both traditional sensitizers, and those that work by suppressing DNA repair processes. Methods: Six brachytherapy treatment plans were used to model the anatomy, implant geometry and calculate the spatial distribution of radiation dose and drug concentrations for a range of drug diffusion parameters. Three state partial differential equations (cells healthy, damaged or dead) modeled the effect of continuous radiation (radiosensitivities α,β) and cellular repair (time tr) on a cell population. Radiosensitization was modeled as concentration dependent change in α,β or tr which with variable duration under the constraint of fixed total drug release. Average cell kill was used to measure effectiveness. Sensitization by means of both enhanced damage and reduced repair were studied. Results: Optimal release duration is dependent on the concentration of radiosensitizer compared to the saturation concentration (csat) above which additional sensitization does not occur. Long duration drug release when enhancing α or β maximizes cell death when drug concentrations are generally over csat. Short term release is optimal for concentrations below saturation. Sensitization by suppressing repair has a similar though less distinct trend that is more affected by the radiation dose distribution. Conclusion: Models of sustained local radiosensitization show potential to increase the effectiveness of radiation in permanent prostate brachytherapy. INCeRTs with high drug capacity produce the greatest

  14. Building an Efficient Model for Afterburn Energy Release

    Energy Technology Data Exchange (ETDEWEB)

    Alves, S; Kuhl, A; Najjar, F; Tringe, J; McMichael, L; Glascoe, L

    2012-02-03

    Many explosives will release additional energy after detonation as the detonation products mix with the ambient environment. This additional energy release, referred to as afterburn, is due to combustion of undetonated fuel with ambient oxygen. While the detonation energy release occurs on a time scale of microseconds, the afterburn energy release occurs on a time scale of milliseconds with a potentially varying energy release rate depending upon the local temperature and pressure. This afterburn energy release is not accounted for in typical equations of state, such as the Jones-Wilkins-Lee (JWL) model, used for modeling the detonation of explosives. Here we construct a straightforward and efficient approach, based on experiments and theory, to account for this additional energy release in a way that is tractable for large finite element fluid-structure problems. Barometric calorimeter experiments have been executed in both nitrogen and air environments to investigate the characteristics of afterburn for C-4 and other materials. These tests, which provide pressure time histories, along with theoretical and analytical solutions provide an engineering basis for modeling afterburn with numerical hydrocodes. It is toward this end that we have constructed a modified JWL equation of state to account for afterburn effects on the response of structures to blast. The modified equation of state includes a two phase afterburn energy release to represent variations in the energy release rate and an afterburn energy cutoff to account for partial reaction of the undetonated fuel.

  15. A real-time PUFF-model for accidental releases in complex terrain

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Mikkelsen, T.; Larsen, S.E.; Troen, I.; Baas, A.F. de; Kamada, R.; Skupniewicz, C.; Schacher, G.

    1990-01-01

    LINCOM-RIMPUFF, a combined flow/puff model, was developed at Riso National Laboratory for the Vandenberg AFB Meteorology and Plume Dispersion Handbook and is suitable as is for real time response to emergency spills and vents of gases and radionuclides. LINCOM is a linear, diagnostic, spectral, potential flow model which extends the Jackson-Hunt theory of non-hydrostatic, adiabatic wind flow over hills to the mesoscale domain. It is embedded in a weighted objective analysis (WOA) of real-time Vandenberg tower winds and may be used in ultra-high speed lookup table mode. The mesoscale dispersion model RIMPUFF is a flexible Gaussian puff model equipped with computer-time effective features for terrain and stability-dependent dispersion parameterization, plume rise formulas, inversion and ground-level reflection capabilities and wet/dry (source) depletion. It can treat plume bifurcation in complex terrain by using a puff-splitting scheme. It allows the flow-model to compute the larger scale wind field, reserving turbulent diffusion calculations for the sub-grid scale. In diagnostic mode toxic exposure are well assessed via the release of a single initial puff. With optimization, processing time for RIMPUFF should be on the order of 2 CPU minutes or less on a PC-system. In prognostic mode with shifting winds, multiple puff releases may become necessary, thereby lengthening processing time

  16. Air exposure and sample storage time influence on hydrogen release from tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Moshkunov, K.A., E-mail: moshkunov@gmail.co [National Research Nuclear University ' MEPhI' , Kashirskoe sh. 31, 115409 Moscow (Russian Federation); Schmid, K.; Mayer, M. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Kurnaev, V.A.; Gasparyan, Yu.M. [National Research Nuclear University ' MEPhI' , Kashirskoe sh. 31, 115409 Moscow (Russian Federation)

    2010-09-30

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D{sub 2}O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of {approx}300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  17. Air exposure and sample storage time influence on hydrogen release from tungsten

    International Nuclear Information System (INIS)

    Moshkunov, K.A.; Schmid, K.; Mayer, M.; Kurnaev, V.A.; Gasparyan, Yu.M.

    2010-01-01

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D 2 O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of ∼300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  18. Air exposure and sample storage time influence on hydrogen release from tungsten

    Science.gov (United States)

    Moshkunov, K. A.; Schmid, K.; Mayer, M.; Kurnaev, V. A.; Gasparyan, Yu. M.

    2010-09-01

    In investigations of hydrogen retention in first wall components the influence of the conditions of the implanted target storage prior to analysis and the storage time is often neglected. Therefore we have performed a dedicated set of experiments. The release of hydrogen from samples exposed to ambient air after irradiation was compared to samples kept in vacuum. For air exposed samples significant amounts of HDO and D 2O are detected during TDS. Additional experiments have shown that heavy water is formed by recombination of releasing D and H atoms with O on the W surface. This water formation can alter hydrogen retention results significantly, in particular - for low retention cases. In addition to the influence of ambient air exposure also the influence of storage time in vacuum was investigated. After implantation at 300 K the samples were stored in vacuum for up to 1 week during which the retained amount decreased significantly. The subsequently measured TDS spectra showed that D was lost from both the high and low energy peaks during storage at ambient temperature of ˜300 K. An attempt to simulate this release from both peaks during room temperature storage by TMAP 7 calculations showed that this effect cannot be explained by conventional diffusion/trapping models.

  19. Timing of insertion of levonorgestrel-releasing intrauterine system : a randomised controlled trial

    NARCIS (Netherlands)

    van der Heijden, Pahh; Geomini, Pmaj; Herman, M C; Veersema, S; Bongers, M Y

    OBJECTIVE: The objective was to assess whether patient-perceived pain during the insertion of the levonorgestrel-releasing intrauterine system (LNG-IUS) depends on the timing during the menstrual cycle. DESIGN: A stratified two-armed non-inferiority randomised controlled trial. SETTING: Large

  20. Simplified method for measuring the response time of scram release electromagnet in a nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Patri, Sudheer, E-mail: patri@igcar.gov.in; Mohana, M.; Kameswari, K.; Kumar, S. Suresh; Narmadha, S.; Vijayshree, R.; Meikandamurthy, C.; Venkatesan, A.; Palanisami, K.; Murthy, D. Thirugnana; Babu, B.; Prakash, V.; Rajan, K.K.

    2015-04-15

    Highlights: • An alternative method for estimating the electromagnet clutch release time. • A systematic approach to develop a computer based measuring system. • Prototype tests on the measurement system. • Accuracy of the method is ±6% and repeatability error is within 2%. - Abstract: The delay time in electromagnet clutch release during a reactor trip (scram action) is an important safety parameter, having a bearing on the plant safety during various design basis events. Generally, it is measured using current decay characteristics of electromagnet coil and its energising circuit. A simplified method of measuring the same in a Sodium cooled fast reactors (SFR) is proposed in this paper. The method utilises the position data of control rod to estimate the delay time in electromagnet clutch release. A computer based real time measurement system for measuring the electromagnet clutch delay time is developed and qualified for retrofitting in prototype fast breeder reactor. Various stages involved in the development of the system are principle demonstration, experimental verification of hardware capabilities and prototype system testing. Tests on prototype system have demonstrated the satisfactory performance of the system with intended accuracy and repeatability.

  1. Application of time release electron donors and electron acceptors for accelerated bioremediation

    International Nuclear Information System (INIS)

    Joksimovich, V.; Koenigsberg, S.

    2002-01-01

    Currently, there are limited options for cost effective approaches to soil and groundwater contamination. One technology that has proven its potential involves the use of time release electron acceptors to accelerate the natural bioattenuation of aerobically degradable compounds and time release electron donors to accelerate the natural bioattenuation of anaerobic compounds. This technology enjoys its reputations as a sensible strategy for engineering accelerated bioattenuation, because it delivers results while 1) limiting or eliminating design, capital and management costs and 2) allowing for the engineering of a low-impact application and a subsequently invisible remediation process. Oxygen Release Compound (ORC ) is proprietary formulation of intercalated magnesium peroxide that releases oxygen slowly, for about a year, and facilitates the aerobic degradation of a range of environmental contaminants including petroleum hydrocarbons, certain chlorinated hydrocarbons, ether oxygenates and nitroaromatics. The history of ORC's introduction and acceptance represents a model for the evolution of an innovative technology. This statement comes by virtue of the fact that since 1994 ORC has been used on over 7000 sites worldwide and has been the subject of an extensive body of literature. Hydrogen Release Compound (HRC) is also a proprietary polylactate ester that is food grade and, upon being deposited into the aquifer, is slowly hydrolyzed to release lactic acid and other organic acid derivatives for about one to two years. The organic acids are fermented to hydrogen, which in turn donates electrons that drive reductive bioattenuation processes. This is primarily directed at a wide range of chlorinated hydrocarbons, but can be applied to the remediation of metals by redox induced precipitation. HRC has now been used on over 220 sites, which we believe make it the most widely used electron donor for accelerating bioattenuation. ORC and HRC can be configured as a

  2. Real-time modeling of complex atmospheric releases in urban areas

    International Nuclear Information System (INIS)

    Baskett, R.L.; Ellis, J.S.; Sullivan, T.J.

    1994-08-01

    If a nuclear installation in or near an urban area has a venting, fire, or explosion, airborne radioactivity becomes the major concern. Dispersion models are the immediate tool for estimating the dose and contamination. Responses in urban areas depend on knowledge of the amount of the release, representative meteorological data, and the ability of the dispersion model to simulate the complex flows as modified by terrain or local wind conditions. A centralized dispersion modeling system can produce realistic assessments of radiological accidents anywhere in a country within several minutes if it is computer-automated. The system requires source-term, terrain, mapping and dose-factor databases, real-time meteorological data acquisition, three-dimensional atmospheric transport and dispersion models, and experienced staff. Experience with past responses in urban areas by the Atmospheric Release Advisory Capability (ARAC) program at Lawrence Livermore National Laboratory illustrate the challenges for three-dimensional dispersion models

  3. Real-time modelling of complex atmospheric releases in urban areas

    International Nuclear Information System (INIS)

    Baskett, R.L.; Ellis, J.S.; Sullivan, T.J.

    2000-01-01

    If a nuclear installation in or near an urban area has a venting, fire, or explosion, airborne radioactivity becomes the major concern. Dispersion models are the immediate tool for estimating the dose and contamination. Responses in urban areas depend on knowledge of the amount of the release, representative meteorological data, and the ability of the dispersion model to simulate the complex flows as modified by terrain or local wind conditions. A centralised dispersion modelling system can produce realistic assessments of radiological accidents anywhere in a country within several minutes if it is computer-automated. The system requires source-term, terrain, mapping and dose-factor databases, real-time meteorological data acquisition, three-dimensional atmospheric transport and dispersion models, and experienced staff. Experience with past responses in urban areas by the Atmospheric Release Advisory Capability (ARAC) program at Lawrence Livermore National Laboratory illustrate the challenges for three-dimensional dispersion models. (author)

  4. Effect of increased exposure times on amount of residual monomer released from single-step self-etch adhesives.

    Science.gov (United States)

    Altunsoy, Mustafa; Botsali, Murat Selim; Tosun, Gonca; Yasar, Ahmet

    2015-10-16

    The aim of this study was to evaluate the effect of increased exposure times on the amount of residual Bis-GMA, TEGDMA, HEMA and UDMA released from single-step self-etch adhesive systems. Two adhesive systems were used. The adhesives were applied to bovine dentin surface according to the manufacturer's instructions and were polymerized using an LED curing unit for 10, 20 and 40 seconds (n = 5). After polymerization, the specimens were stored in 75% ethanol-water solution (6 mL). Residual monomers (Bis-GMA, TEGDMA, UDMA and HEMA) that were eluted from the adhesives (after 10 minutes, 1 hour, 1 day, 7 days and 30 days) were analyzed by high-performance liquid chromatography (HPLC). The data were analyzed using 1-way analysis of variance and Tukey HSD tests. Among the time periods, the highest amount of released residual monomers from adhesives was observed in the 10th minute. There were statistically significant differences regarding released Bis-GMA, UDMA, HEMA and TEGDMA between the adhesive systems (p<0.05). There were no significant differences among the 10, 20 and 40 second polymerization times according to their effect on residual monomer release from adhesives (p>0.05). Increasing the polymerization time did not have an effect on residual monomer release from single-step self-etch adhesives.

  5. Fight and air exposure times of caught and released salmonids from the South Fork Snake River

    Science.gov (United States)

    Roth, Curtis J.; Schill, Daniel J.; Quist, Michael C.

    2018-01-01

    Catch-and-release regulations are among the most common types of fishing regulations. In recent years, concerns have arisen regarding the exposure of fish to air during catch-and-release angling. The purpose of our study was to quantify the length of time angled fish were exposed to air by anglers in a typical catch-and-release fishery and relate it to the lengths of time reported to produce negative effects. In total, 312 individual anglers were observed on the South Fork Snake River, Idaho, from May through August 2016. Fight time varied from 1.1 s to 230.0 s, and average fight time was 40.0 s (SD = 36.8). Total air exposure times varied from 0.0 s to 91.8 s and averaged 19.3 s (SD = 15.0). Though not statistically significant, a trend in reduced fight times was observed when anglers were guided and increased air exposure times when a net was used and a picture was taken. Results of the current study suggest that anglers expose fish to air for periods that are much less than those reported to cause mortality.

  6. A smart hydrogel-based time bomb triggers drug release mediated by pH-jump reaction

    Directory of Open Access Journals (Sweden)

    Prapatsorn Techawanitchai, Naokazu Idota, Koichiro Uto, Mitsuhiro Ebara and Takao Aoyagi

    2012-01-01

    Full Text Available We demonstrate a timed explosive drug release from smart pH-responsive hydrogels by utilizing a phototriggered spatial pH-jump reaction. A photoinitiated proton-releasing reaction of o-nitrobenzaldehyde (o-NBA was integrated into poly(N-isopropylacrylamide-co-2-carboxyisopropylacrylamide (P(NIPAAm-co-CIPAAm hydrogels. o-NBA-hydrogels demonstrated the rapid release of protons upon UV irradiation, allowing the pH inside the gel to decrease to below the pKa value of P(NIPAAm-co-CIPAAm. The generated protons diffused gradually toward the non-illuminated area, and the diffusion kinetics could be controlled by adjusting the UV irradiation time and intensity. After irradiation, we observed the enhanced release of entrapped L-3,4-dihydroxyphenylalanine (DOPA from the gels, which was driven by the dissociation of DOPA from CIPAAm. Local UV irradiation also triggered the release of DOPA from the non-illuminated area in the gel via the diffusion of protons. Conventional systems can activate only the illuminated region, and their response is discontinuous when the light is turned off. The ability of the proposed pH-jump system to permit gradual activation via proton diffusion may be beneficial for the design of predictive and programmable devices for drug delivery.

  7. 77 FR 34010 - Notice of Opportunity To Submit Comment on the Public Release Time of Several Major USDA...

    Science.gov (United States)

    2012-06-08

    ... Statistics Service and Office of the Chief Economist, Department of Agriculture. ACTION: Notice and request... the Chief Economist are currently accepting stakeholder input on the public release time and... the Chief Economist are seeking comments on the release time of several of their major statistical...

  8. Timing of pollen release and stigma receptivity period of Piper vicosanum: New insights into sexual reproduction of the genus.

    Science.gov (United States)

    Valentin-Silva, Adriano; Coelho, Victor Peçanha de Miranda; Ventrella, Marília Contin; Vieira, Milene Faria

    2015-04-01

    Dichogamy is a common characteristic among angiosperms, including Piper species. In this genus, the tiny flowers are morphologically similar and have an asynchronous stamen development. However, there is no information on the duration of stigma receptivity and whether it overlaps with pollen release. To better understand mechanisms of floral function in Piper vicosanum, we provide a detailed characterization of the timing of pollen release from the four stamens and the period of stigma receptivity and exposure mode of the receptive areas. We investigated plants of a natural population in a semideciduous seasonal forest (Viçosa, Minas Gerais State, southeastern Brazil), based on chemical tests, light microscopy, and scanning electron microscopy analyses. Incomplete protogyny-a mechanism that favors outcrossing-was recorded. The period of stigma receptivity was long (14 d), and the sequential exposure and senescence of stigmatic papillae occurred gradually and in a basipetal direction. Pollen release began 2-6 d after the beginning of the pistillate phase, with an average pollen viability of 87.7%, during the bisexual flower phase. Pollen was released for up to 6 d and occurred in one stamen at a time. The fruit set observed in tests of self-pollination indicated self-compatibility. The gradual and sequential exposure of stigmatic papillae in P. vicosanum flowers is described here as the mechanism for the long duration of receptivity. Anther development and pollen release were also sequential. These findings are yet unreported reproductive characteristics of the genus and offer new perspectives for future studies on the floral biology of other Piper species. © 2015 Botanical Society of America, Inc.

  9. A New Perspective on Binaural Integration Using Response Time Methodology: Super Capacity Revealed in Conditions of Binaural Masking Release

    Directory of Open Access Journals (Sweden)

    Jennifer eLentz

    2014-08-01

    Full Text Available This study applied reaction-time based methods to assess the workload capacity of binaural integration by comparing reaction time distributions for monaural and binaural tone-in-noise detection tasks. In the diotic contexts, an identical tone + noise stimulus was presented to each ear. In the dichotic contexts, an identical noise was presented to each ear, but the tone was presented to one of the ears 180o out of phase with respect to the other ear. Accuracy-based measurements have demonstrated a much lower signal detection threshold for the dichotic versus the diotic conditions, but accuracy-based techniques do not allow for assessment of system dynamics or resource allocation across time. Further, reaction times allow comparisons between these conditions at the same signal-to-noise ratio. Here, we apply a reaction-time based capacity coefficient, which provides an index of workload efficiency and quantifies the resource allocations for single ear versus two ear presentations. We demonstrate that the release from masking generated by the addition of an identical stimulus to one ear is limited-to-unlimited capacity (efficiency typically less than 1, consistent with less gain than would be expected by probability summation. However, the dichotic presentation leads to a significant increase in workload capacity (increased efficiency – most specifically at lower signal-to-noise ratios. These experimental results provide further evidence that configural processing plays a critical role in binaural masking release, and that these mechanisms may operate more strongly when the signal stimulus is difficult to detect, albeit still with nearly 100% accuracy.

  10. Single-machine scheduling with release dates, due dates and family setup times

    NARCIS (Netherlands)

    Schutten, Johannes M.J.; van de Velde, S.L.; van de Velde, S.L.; Zijm, Willem H.M.

    1996-01-01

    We address the NP-hard problem of scheduling n independent jobs with release dates, due dates, and family setup times on a single machine to minimize the maximum lateness. This problem arises from the constant tug-of-war going on in manufacturing between efficient production and delivery

  11. Ratiometric two-photon excited photoluminescence of quantum dots triggered by near-infrared-light for real-time detection of nitric oxide release in situ

    International Nuclear Information System (INIS)

    Jin, Hui; Gui, Rijun; Sun, Jie; Wang, Yanfeng

    2016-01-01

    Probe-donor integrated nanocomposites were developed from conjugating silica-coated Mn"2"+:ZnS quantum dots (QDs) with MoS_2 QDs and photosensitive nitric oxide (NO) donors (Fe_4S_3(NO)_7"−, RBS). Under excitation with near-infrared (NIR) light at 808 nm, the Mn"2"+:ZnS@SiO_2/MoS_2-RBS nanocomposites showed the dual-emissive two-photon excited photoluminescence (TPEPL) that induced RBS photolysis to release NO in situ. NO caused TPEPL quenching of Mn"2"+:ZnS QDs, but it produced almost no impact on the TPEPL of MoS_2 QDs. Hence, the nanocomposites were developed as a novel QDs-based ratiometric TPEPL probe for real-time detection of NO release in situ. The ratiometric TPEPL intensity is nearly linear (R"2 = 0.9901) with NO concentration in the range of 0.01∼0.8 μM, which corresponds to the range of NO release time (0∼15 min). The detection limit was calculated to be approximately 4 nM of NO. Experimental results confirmed that this novel ratiometric TPEPL probe possessed high selectivity and sensitivity for the detection of NO against potential competitors, and especially showed high detection performance for NIR-light triggered NO release in tumor intracellular microenvironments. These results would promote the development of versatile probe-donor integrated systems, also providing a facile and efficient strategy to real-time detect the highly controllable drug release in situ, especially in physiological microenvironments. - Highlights: • Mn"2"+:ZnS@SiO_2/MoS_2-RBS nanocomposites were developed as a novel ratiometric two-photon excited fluorescence probe. • This probe could conduct real-time detection of nitric oxide release in situ. • High feasibility of this probe was confirmed in tumor intracellular microenvironments.

  12. Single-machine scheduling with release dates, due dates, and family setup times

    NARCIS (Netherlands)

    J.M.J. Schutten (Marco); S.L. van de Velde (Steef); W.H.M. Zijm

    1996-01-01

    textabstractWe address the NP-hard problem of scheduling n independent jobs with release dates, due dates, and family setup times on a single machine to minimize the maximum lateness. This problem arises from the constant tug-of-war going on in manufacturing between efficient production and delivery

  13. Effect of the timing of tourniquet release on postoperative hematoma formation: an experimental animal study

    Energy Technology Data Exchange (ETDEWEB)

    Himel, H.N.; Ahmad, M.; Parmett, S.R.; Strauss, H.W.; May, J.W. Jr.

    1989-04-01

    There is a controversy over when to release a pneumatic tourniquet after completing a hand surgical procedure. To study this controversy, we performed a standardized operation with tourniquet inflow occlusion on both lower legs of a series of rabbits. Total tourniquet time and the procedure performed, including intraoperative Bovie electrocautery of actual and potential bleeding points identified with 2.5 X loupe magnification, were identical on the two sides, except for the method of tourniquet release. On one leg, the tourniquet was released and all new bleeding points were controlled prior to wound closure. On the other leg, the tourniquet was released after the wound had been closed and dressed. Animals were injected with technetium-99m-labeled red blood cells and scanned to measure hematoma formation. Qualitatively, we observed more label in the leg whose tourniquet was released after wound closure in 17 of the 20 animals (p less than 0.005). Quantitatively, we also measured more mean label in the leg whose tourniquet was released after the wound was closed (p less than 0.001). Tourniquet release after wound closure was associated with greater hematoma formation.

  14. Effect of the timing of tourniquet release on postoperative hematoma formation: an experimental animal study

    International Nuclear Information System (INIS)

    Himel, H.N.; Ahmad, M.; Parmett, S.R.; Strauss, H.W.; May, J.W. Jr.

    1989-01-01

    There is a controversy over when to release a pneumatic tourniquet after completing a hand surgical procedure. To study this controversy, we performed a standardized operation with tourniquet inflow occlusion on both lower legs of a series of rabbits. Total tourniquet time and the procedure performed, including intraoperative Bovie electrocautery of actual and potential bleeding points identified with 2.5 X loupe magnification, were identical on the two sides, except for the method of tourniquet release. On one leg, the tourniquet was released and all new bleeding points were controlled prior to wound closure. On the other leg, the tourniquet was released after the wound had been closed and dressed. Animals were injected with technetium-99m-labeled red blood cells and scanned to measure hematoma formation. Qualitatively, we observed more label in the leg whose tourniquet was released after wound closure in 17 of the 20 animals (p less than 0.005). Quantitatively, we also measured more mean label in the leg whose tourniquet was released after the wound was closed (p less than 0.001). Tourniquet release after wound closure was associated with greater hematoma formation

  15. A real-time positron monitor for the estimation of stack effluent releases from PET medical cyclotron facilities

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar.

    2002-01-01

    Large activities of short-lived positron emitting radiopharmaceuticals are routinely manufactured by modern Medical Cyclotron facilities for positron emission tomography (PET) applications. During radiochemical processing, a substantial fraction of the volatile positron emitting radiopharmaceuticals are released into the atmosphere. An inexpensive, fast response positron detector using a simple positron-annihilation chamber has been developed for real-time assessment of the stack release of positron emitting effluents at the Australian National Medical Cyclotron. The positron detector was calibrated by using a 3.0 ml (1.50 MBq) aliquot of 18 FDG and interfaced to an industrial standard datalogger for the real-time acquisition of stack release data

  16. A new perspective on binaural integration using response time methodology: super capacity revealed in conditions of binaural masking release.

    Science.gov (United States)

    Lentz, Jennifer J; He, Yuan; Townsend, James T

    2014-01-01

    This study applied reaction-time based methods to assess the workload capacity of binaural integration by comparing reaction time (RT) distributions for monaural and binaural tone-in-noise detection tasks. In the diotic contexts, an identical tone + noise stimulus was presented to each ear. In the dichotic contexts, an identical noise was presented to each ear, but the tone was presented to one of the ears 180° out of phase with respect to the other ear. Accuracy-based measurements have demonstrated a much lower signal detection threshold for the dichotic vs. the diotic conditions, but accuracy-based techniques do not allow for assessment of system dynamics or resource allocation across time. Further, RTs allow comparisons between these conditions at the same signal-to-noise ratio. Here, we apply a reaction-time based capacity coefficient, which provides an index of workload efficiency and quantifies the resource allocations for single ear vs. two ear presentations. We demonstrate that the release from masking generated by the addition of an identical stimulus to one ear is limited-to-unlimited capacity (efficiency typically less than 1), consistent with less gain than would be expected by probability summation. However, the dichotic presentation leads to a significant increase in workload capacity (increased efficiency)-most specifically at lower signal-to-noise ratios. These experimental results provide further evidence that configural processing plays a critical role in binaural masking release, and that these mechanisms may operate more strongly when the signal stimulus is difficult to detect, albeit still with nearly 100% accuracy.

  17. Secure information release in timed automata

    DEFF Research Database (Denmark)

    Vasilikos, Panagiotis; Nielson, Flemming; Nielson, Hanne Riis

    2018-01-01

    . In this paper, we develop a formal approach of information flow for timed automata that allows intentional information leaks. The security of a timed automaton is then defined using a bisimulation relation that takes account of the non-determinism and the clocks of timed automata. Finally, we define...... of security goals for confidentiality and integrity. Notions of security based on Information flow control, such as non-interference, provide strong guarantees that no information is leaked; however, many cyberphysical systems leak intentionally some information in order to achieve their purposes...... an algorithm that traverses a timed automaton and imposes information flow constraints on it and we prove that our algorithm is sound with respect to our security notion....

  18. Time-dependent histamine release from stored human blood products

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørgen; Edvardsen, L; Vangsgaard, K

    1996-01-01

    storage. Whole blood (six units), plasma-reduced whole blood (six units), and plasma- and buffy coat-reduced (saline-adenine-glucose-mannitol) (SAGM) blood (six units) from unpaid healthy donors were stored in the blood bank for 35 days at 4 degrees C. Plasma histamine and total cell-bound histamine......Perioperative transfusion of whole blood has been shown to amplify trauma-induced immunosuppression, which could be attenuated by perioperative administration of histamine2 receptor antagonists. Supernatants from different blood products were, therefore, analysed for histamine content during.......0 (range 176.0-910.0) nmol/l in whole blood and 475.0 (range 360.0-1560.0) nmol/l in plasma-reduced whole blood, while it was undetectable in SAGM blood. Spontaneous histamine release increased in a time-dependent manner from a median of 6.7 (range 2.2-17.4) nmol/l at the time of storage to 175.0 (range 33...

  19. Pramipexole Extended Release: A Novel Treatment Option in Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Wolfram Eisenreich

    2010-01-01

    Full Text Available Pramipexole, the most commonly prescribed dopamine agonist worldwide, meanwhile serves as a reference substance for evaluation of new drugs. Based on numerous clinical data and vast experiences, efficacy and safety profiles of this non-ergoline dopamine agonist are well characterized. Since October 2009, an extended-release formulation of pramipexole has been available for symptomatic treatment of Parkinson's disease. Pramipexole administration can be cut down from three times to once a day due to the newly developed extended-release formulation. This is considerable progress in regard to minimizing pill burden and enhancing compliance. Moreover, the 24 h continuous drug release of the once-daily extended-release formulation results in fewer fluctuations in plasma concentrations over time compared to immediate-release pramipexole, given three times daily. The present study summarizes pharmacokinetics and all essential pharmacological and clinical characteristics of the extended-release formulation. In addition, it provides all study data, available so far, with regard to transition and de-novo administration of extended-release formulation for patients with Parkinson's disease. It further compares efficacy and safety data of immediate-release pramipexole with the extended-release formulation of pramipexole.

  20. Fabrication of thin SU-8 cantilevers: initial bending, release and time stability

    International Nuclear Information System (INIS)

    Keller, Stephan; Boisen, Anja; Haefliger, Daniel

    2010-01-01

    SU-8 cantilevers with a thickness of 2 µm were fabricated using a dry release method and two steps of SU-8 photolithography. The processing of the thin SU-8 film defining the cantilevers was experimentally optimized to achieve low initial bending due to residual stress gradients. In parallel, the rotational deformation at the clamping point allowed a qualitative assessment of the device release from the fluorocarbon-coated substrate. The change of these parameters during several months of storage at ambient temperature was investigated in detail. The introduction of a long hard bake in an oven after development of the thin SU-8 film resulted in reduced cantilever bending due to removal of residual stress gradients. Further, improved time-stability of the devices was achieved due to the enhanced cross-linking of the polymer. A post-exposure bake at a temperature T PEB = 50 °C followed by a hard bake at T HB = 90 °C proved to be optimal to ensure low cantilever bending and low rotational deformation due to excellent device release and low change of these properties with time. With the optimized process, the reproducible fabrication of arrays with 2 µm thick cantilevers with a length of 500 µm and an initial bending of less than 20 µm was possible. The theoretical spring constant of these cantilevers is k = 4.8 ± 2.5 mN m −1 , which is comparable to the value for Si cantilevers with identical dimensions and a thickness of 500 nm.

  1. Ratiometric two-photon excited photoluminescence of quantum dots triggered by near-infrared-light for real-time detection of nitric oxide release in situ

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hui [Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Collaborative Innovation Center for Marine Biomass Fiber Materials and Textiles, College of Chemistry and Chemical Engineering, Laboratory of Fiber Materials and Modern Textile, The Growing Base for State Key Laboratory, Qingdao University, Shandong 266071 (China); Gui, Rijun, E-mail: guirijun@qdu.edu.cn [Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Collaborative Innovation Center for Marine Biomass Fiber Materials and Textiles, College of Chemistry and Chemical Engineering, Laboratory of Fiber Materials and Modern Textile, The Growing Base for State Key Laboratory, Qingdao University, Shandong 266071 (China); Sun, Jie; Wang, Yanfeng [Institute of Materia Medica, Shandong Academy of Medical Sciences, Jinan 250062 (China)

    2016-05-30

    Probe-donor integrated nanocomposites were developed from conjugating silica-coated Mn{sup 2+}:ZnS quantum dots (QDs) with MoS{sub 2} QDs and photosensitive nitric oxide (NO) donors (Fe{sub 4}S{sub 3}(NO){sub 7}{sup −}, RBS). Under excitation with near-infrared (NIR) light at 808 nm, the Mn{sup 2+}:ZnS@SiO{sub 2}/MoS{sub 2}-RBS nanocomposites showed the dual-emissive two-photon excited photoluminescence (TPEPL) that induced RBS photolysis to release NO in situ. NO caused TPEPL quenching of Mn{sup 2+}:ZnS QDs, but it produced almost no impact on the TPEPL of MoS{sub 2} QDs. Hence, the nanocomposites were developed as a novel QDs-based ratiometric TPEPL probe for real-time detection of NO release in situ. The ratiometric TPEPL intensity is nearly linear (R{sup 2} = 0.9901) with NO concentration in the range of 0.01∼0.8 μM, which corresponds to the range of NO release time (0∼15 min). The detection limit was calculated to be approximately 4 nM of NO. Experimental results confirmed that this novel ratiometric TPEPL probe possessed high selectivity and sensitivity for the detection of NO against potential competitors, and especially showed high detection performance for NIR-light triggered NO release in tumor intracellular microenvironments. These results would promote the development of versatile probe-donor integrated systems, also providing a facile and efficient strategy to real-time detect the highly controllable drug release in situ, especially in physiological microenvironments. - Highlights: • Mn{sup 2+}:ZnS@SiO{sub 2}/MoS{sub 2}-RBS nanocomposites were developed as a novel ratiometric two-photon excited fluorescence probe. • This probe could conduct real-time detection of nitric oxide release in situ. • High feasibility of this probe was confirmed in tumor intracellular microenvironments.

  2. AEROS: a real-time emergency response system for atmospheric releases of toxic material

    International Nuclear Information System (INIS)

    Nasstrom, J.S.; Greenly, G.D.

    1986-01-01

    The Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory has developed a sophisticated computer-based real-time emergency response system for radiotoxic releases into the atmosphere. The ARAC Emergency Response Operating System (AEROS) has a centralized computer facility linked to remote site computers, meteorological towers, and meteorological data sources. The system supports certain fixed sites, but has the ability to respond to accidents at arbitrary locations. Product quality and response time are optimized by using complex three-dimensional dispersion models; extensive on-line data bases; automated data processing; and an efficient user interface, employing graphical computer displays and computer-displayed forms. Upon notification, the system automatically initiates a response to an emergency and proceeds through preliminary calculations, automatically processing accident information, meteorological data, and model parameters. The model calculations incorporate mass-consistent three-dimensional wind fields, terrain effects, and particle-in-cell diffusion. Model products are color images of dose or deposition contours overlaid on a base map

  3. Influence of Actively Controlled Heat Release Timing on the Performance and Operational Characteristics of a Rotary Valve, Acoustically Resonant Pulse Combustor

    KAUST Repository

    Lisanti, Joel; Roberts, William L.

    2017-01-01

    The influence of heat release timing on the performance and operational characteristics of a rotary valve, acoustically resonant pulse combustor is investigated both experimentally and numerically. Simulation results are obtained by solving the quasi-1D Navier-Stokes equations with forced volumetric heat addition. Experimental efforts modify heat release timing through modulated fuel injection and modification of the fluid dynamic mixing. Results indicate that the heat release timing has a profound effect on the operation and efficiency of the pulse combustor and that this timing can be difficult to control experimentally.

  4. Influence of Actively Controlled Heat Release Timing on the Performance and Operational Characteristics of a Rotary Valve, Acoustically Resonant Pulse Combustor

    KAUST Repository

    Lisanti, Joel

    2017-01-05

    The influence of heat release timing on the performance and operational characteristics of a rotary valve, acoustically resonant pulse combustor is investigated both experimentally and numerically. Simulation results are obtained by solving the quasi-1D Navier-Stokes equations with forced volumetric heat addition. Experimental efforts modify heat release timing through modulated fuel injection and modification of the fluid dynamic mixing. Results indicate that the heat release timing has a profound effect on the operation and efficiency of the pulse combustor and that this timing can be difficult to control experimentally.

  5. Minimizing Total Completion Time For Preemptive Scheduling With Release Dates And Deadline Constraints

    Directory of Open Access Journals (Sweden)

    He Cheng

    2014-02-01

    Full Text Available It is known that the single machine preemptive scheduling problem of minimizing total completion time with release date and deadline constraints is NP- hard. Du and Leung solved some special cases by the generalized Baker's algorithm and the generalized Smith's algorithm in O(n2 time. In this paper we give an O(n2 algorithm for the special case where the processing times and deadlines are agreeable. Moreover, for the case where the processing times and deadlines are disagreeable, we present two properties which could enable us to reduce the range of the enumeration algorithm

  6. Radiological effluents released from US continental tests, 1961 through 1992. Revision 1

    International Nuclear Information System (INIS)

    Schoengold, C.R.; DeMarre, M.E.; Kirkwood, E.M.

    1996-08-01

    This report documents all continental tests from September 15, 1961, through September 23, 1992, from which radioactive effluents were released. The report includes both updated information previously published in the publicly available May, 1990 report, DOE/NV-317, ''Radiological Effluents Released from Announced US Continental Tests 1961 through 1988'', and effluent release information on formerly unannounced tests. General information provided for each test includes the date, time, location, type of test, sponsoring laboratory and/or agency or other sponsor, depth of burial, purpose, yield or yield range, extent of release (onsite only or offsite), and category of release (detonation-time versus post-test operations). Where a test with simultaneous detonations is listed, location, depth of burial and yield information are given for each detonation if applicable, as well as the specific source of the release. A summary of each release incident by type of release is included. For a detonation-time release, the effluent curies are expressed at R+12 hours. For a controlled releases from tunnel-tests, the effluent curies are expressed at both time of release and at R+12 hours. All other types are listed at the time of the release. In addition, a qualitative statement of the isotopes in the effluent is included for detonation-time and controlled releases and a quantitative listing is included for all other types. Offsite release information includes the cloud direction, the maximum activity detected in the air offsite, the maximum gamma exposure rate detected offsite, the maximum iodine level detected offsite, and the maximum distance radiation was detected offsite. A release summary incudes whatever other pertinent information is available for each release incident. This document includes effluent release information for 433 tests, some of which have simultaneous detonations. However, only 52 of these are designated as having offsite releases

  7. Radiological effluents released from US continental tests, 1961 through 1992. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Schoengold, C.R.; DeMarre, M.E.; Kirkwood, E.M.

    1996-08-01

    This report documents all continental tests from September 15, 1961, through September 23, 1992, from which radioactive effluents were released. The report includes both updated information previously published in the publicly available May, 1990 report, DOE/NV-317, ``Radiological Effluents Released from Announced US Continental Tests 1961 through 1988``, and effluent release information on formerly unannounced tests. General information provided for each test includes the date, time, location, type of test, sponsoring laboratory and/or agency or other sponsor, depth of burial, purpose, yield or yield range, extent of release (onsite only or offsite), and category of release (detonation-time versus post-test operations). Where a test with simultaneous detonations is listed, location, depth of burial and yield information are given for each detonation if applicable, as well as the specific source of the release. A summary of each release incident by type of release is included. For a detonation-time release, the effluent curies are expressed at R+12 hours. For a controlled releases from tunnel-tests, the effluent curies are expressed at both time of release and at R+12 hours. All other types are listed at the time of the release. In addition, a qualitative statement of the isotopes in the effluent is included for detonation-time and controlled releases and a quantitative listing is included for all other types. Offsite release information includes the cloud direction, the maximum activity detected in the air offsite, the maximum gamma exposure rate detected offsite, the maximum iodine level detected offsite, and the maximum distance radiation was detected offsite. A release summary incudes whatever other pertinent information is available for each release incident. This document includes effluent release information for 433 tests, some of which have simultaneous detonations. However, only 52 of these are designated as having offsite releases.

  8. Fabrication of thin SU-8 cantilevers: initial bending, release and time stability

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Haefliger, D.; Boisen, Anja

    2010-01-01

    SU-8 cantilevers with a thickness of 2 mu m were fabricated using a dry release method and two steps of SU-8 photolithography. The processing of the thin SU-8 film defining the cantilevers was experimentally optimized to achieve low initial bending due to residual stress gradients. In parallel......, the rotational deformation at the clamping point allowed a qualitative assessment of the device release from the fluorocarbon-coated substrate. The change of these parameters during several months of storage at ambient temperature was investigated in detail. The introduction of a long hard bake in an oven after...... development of the thin SU-8 film resulted in reduced cantilever bending due to removal of residual stress gradients. Further, improved time-stability of the devices was achieved due to the enhanced cross-linking of the polymer. A post-exposure bake at a temperature T-PEB = 50 degrees C followed by a hard...

  9. A comparison of the cytotoxic activity of eosinophils and other cells by 51chromium release and time lapse microcinematography

    International Nuclear Information System (INIS)

    Sanderson, C.J.; Thomas, J.A.

    1978-01-01

    Antibody dependent cytotoxicity of chicken erythrocytes by purified rat eosinophils, neutrophils, macrophages and K cells has been compared by 51 Cr release and time lapse microcinematography. Techniques have been developed for purifying these effector cell types. Both eosinophils and neutrophils caused rapid release of 51 Cr from erythrocytes. Time lapse observations indicated that this was the result of phagocytosis. Eosinophils showed rapid membrane movement and repeatedly engulfed and regurgitated the erythrocytes. On the other hand, neutrophils became quiescent after phagocytosing erythrocytes, and remained quiescent until the remains of the cell were expelled. Neutrophils presumably have a mechanism for the release of soluble material, as 51 Cr was released rapidly. Macrophages showed a similar quiescence after phagocytosis, but in these cells there was apparently no rapid mechanism to expel material, as there was no significant 51 Cr release over 20 h. K cells appeared to damage chicken erythrocytes more slowly than they destroyed tumour cells. Mast cells caused antibody-independent cytotoxicity which can be attributed to the release of toxic materials. None of these effector cells produced the type of lysis seen with antibody and complement. (author)

  10. Time-domain study of tectonic strain-release effects on seismic waves from underground nuclear explosions

    International Nuclear Information System (INIS)

    Nakanishi, K.K.; Sherman, N.W.

    1982-09-01

    Tectonic strain release affects both the amplitude and phase of seismic waves from underground nuclear explosions. Surface wave magnitudes are strongly affected by the component of tectonic strain release in the explosion. Amplitudes and radiation patterns of surface waves from explosions with even small tectonic components change magnitudes significantly and show a strong dependence on receiver locations. A thrust-slip source superimposed on an isotropic explosion can explain observed reversals in waveform at different azimuths and phase delays between normal and reversed Rayleigh waves. The mechanism of this reversal is due to the phase relationship between reasonable explosion and tectonic release sources. Spallation or an unusual source time function are not required. The observations of Shagan River events imply thrust-slip motion along faults in a northwest-southeast direction, which is consistent with regional tectonics

  11. Assessment of consequences from airborne releases of radioactive material

    International Nuclear Information System (INIS)

    McGrath, P.E.; Blond, R.M.

    1976-01-01

    Over the past several years, the manner in which assessments have been made of the consequences of large airborne releases of radioactive material has not changed much conceptually. The models to describe the atmospheric dispersion of the radioactive material have generally been time-invariant, i.e., the meteorological conditions (thermal stability, wind speed, and precipitation) are invariant during release and the subsequent period of radiation exposure of the population to the airborne material. The frequency distribution of the meteorological conditions are determined by analyzing several years of weather data from the appropriate geographical location. In reality, weather is continuously changing over short time periods (hours) following the release. It is to be expected that the changing meteorological conditions would have important effects on the potential consequences of the release. A time-dependent atmospheric dispersion model was developed and implemented in the Reactor Safety Study. This paper provides a description of the model and the nature of the results generated. Emphasis is given to an explanation of how, and why, these results differ from those estimated with time-invariant models

  12. Real-time water quality monitoring and providing water quality ...

    Science.gov (United States)

    EPA and the U.S. Geological Survey (USGS) have initiated the “Village Blue” research project to provide real-time water quality monitoring data to the Baltimore community and increase public awareness about local water quality in Baltimore Harbor and the Chesapeake Bay. The Village Blue demonstration project complements work that a number of state and local organizations are doing to make Baltimore Harbor “swimmable and fishable” 2 by 2020. Village Blue is designed to build upon EPA’s “Village Green” project which provides real-time air quality information to communities in six locations across the country. The presentation, “Real-time water quality monitoring and providing water quality information to the Baltimore Community”, summarizes the Village Blue real-time water quality monitoring project being developed for the Baltimore Harbor.

  13. Analysis of Silicones Released from Household Items and Baby Articles by Direct Analysis in Real Time-Mass Spectrometry

    Science.gov (United States)

    Gross, Jürgen H.

    2015-03-01

    Direct analysis in real time-mass spectrometry (DART-MS) enables screening of articles of daily use made of polydimethylsiloxanes (PDMS), commonly known as silicone rubber, to assess their tendency to release low molecular weight silicone oligomers. DART-MS analyses were performed on a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Flexible silicone baking molds, a watch band, and a dough scraper, as baby articles different brands of pacifiers, nipples, and a teething ring have been examined. While somewhat arbitrarily chosen, the set can be regarded as representative of household items, baby articles, and other objects made of silicone rubber. For comparison, two brands of silicone septa and as blanks a glass slide and a latex pacifier were included. Differences between the objects were mainly observed in terms of molecular weight distribution and occasional release of other compounds in addition to PDMS. Other than that, all objects made of silicone rubber released significant amounts of PDMS during DART analysis. To provide a coarse quantification, a calibration based on silicone oil was established, which delivered PDMS losses from 20 μg to >100 μg during the 16-s period per measurement. Also, the extraction of baking molds in rapeseed oil demonstrated a PDMS release at the level of 1 μg mg-1. These findings indicate a potential health hazard from frequent or long-term use of such items. This work does not intend to blame certain brands of such articles. Nonetheless, a higher level of awareness of this source of daily silicone intake is suggested.

  14. Controlled release of tocopherols from polymer blend films

    Science.gov (United States)

    Obinata, Noe

    Controlled release packaging has great potential to increase storage stability of foods by releasing active compounds into foods continuously over time. However, a major limitation in development of this technology is the inability to control the release and provide rates useful for long term storage of foods. Better understanding of the factors affecting active compound release is needed to overcome this limitation. The objective of this research was to investigate the relationship between polymer composition, polymer processing method, polymer morphology, and release properties of active compounds, and to provide proof of principle that compound release is controlled by film morphology. A natural antioxidant, tocopherol was used as a model active compound because it is natural, effective, heat stable, and soluble in most packaging polymers. Polymer blend films were produced from combination of linear low density polyethylene (LLDPE) and high density polyethylene (HDPE), polypropylene (PP), or polystyrene (PS) with 3000 ppm mixed tocopherols using conventional blending method and innovative blending method, smart blending with a novel mixer using chaotic advection. Film morphologies were visualized with scanning electron microscopy (SEM). Release of tocopherols into 95% ethanol as a food simulant was measured by UV/Visible spectrophotometry or HPLC, and diffusivity of tocopherols in the polymers was estimated from this data. Polymer composition (blend proportions) and processing methods have major effects on film morphology. Four different types of morphologies, dispersed, co-continuous, fiber, and multilayer structures were developed by either conventional extrusion or smart blending. With smart blending of fixed polymer compositions, different morphologies were progressively developed with fixed polymer composition as the number of rod rotations increased, providing a way to separate effects of polymer composition and morphology. The different morphologies

  15. Dormancy release and flowering time in Ziziphus jujuba Mill., a "direct flowering" fruit tree, has a facultative requirement for chilling.

    Science.gov (United States)

    Meir, Michal; Ransbotyn, Vanessa; Raveh, Eran; Barak, Simon; Tel-Zur, Noemi; Zaccai, Michele

    2016-03-15

    In deciduous fruit trees, the effect of chilling on flowering has mostly been investigated in the "indirect flowering" group, characterized by a period of rest between flower bud formation and blooming. In the present study, we explored the effects of chilling and chilling deprivation on the flowering of Ziziphus jujuba, a temperate deciduous fruit tree belonging to the "direct flowering" group, in which flower bud differentiation, blooming and fruit development occur after dormancy release, during a single growing season. Dormancy release, vegetative growth and flowering time in Z. jujuba cv. Ben-Li were assessed following several treatments of chilling. Chilling treatments quantitatively decreased the timing of vegetative bud dormancy release, thereby accelerating flowering, but had no effect on the time from dormancy release to flowering. Trees grown at a constant temperature of 25°C, without chilling, broke dormancy and flowered, indicating the facultative character of chilling in this species. We measured the expression of Z. jujuba LFY and AP1 homologues (ZjLFY and ZjAP1). Chilling decreased ZjLFY expression in dormant vegetative buds but had no effect on ZjAP1expression, which reached peak expression before dormancy release and at anthesis. In conclusion, chilling is not obligatory for dormancy release of Z. jujuba cv. Ben-Li vegetative buds. However, the exposure to chilling during dormancy does accelerate vegetative bud dormancy release and flowering. Copyright © 2016 Elsevier GmbH. All rights reserved.

  16. Drug release kinetic analysis and prediction of release data via polymer molecular weight in sustained release diltiazem matrices.

    Science.gov (United States)

    Adibkia, K; Ghanbarzadeh, S; Mohammadi, G; Khiavi, H Z; Sabzevari, A; Barzegar-Jalali, M

    2014-03-01

    This study was conducted to investigate the effects of HPMC (K4M and K100M) as well as tragacanth on the drug release rate of diltiazem (DLTZ) from matrix tablets prepared by direct compression method.Mechanism of drug transport through the matrices was studied by fitting the release data to the 10 kinetic models. 3 model independent parameters; i. e., mean dissolution time (MDT), mean release rate (MRR) and release rate efficacy (RE) as well as 5 time point approaches were established to compare the dissolution profiles. To find correlation between fraction of drug released and polymer's molecular weight, dissolution data were fitted into two proposed equations.All polymers could sustain drug release up to 10 h. The release data were fitted best to Peppas and Higuchi square root kinetic models considering squared correlation coefficient and mean percent error (MPE). RE and MRR were decreased when polymer to drug ratio was increased. Conversely, t60% was increased with raising polymer /drug ratio. The fractions of drug released from the formulations prepared with tragacanth were more than those formulated using the same amount of HPMC K4M and HPMC K100M.Preparation of DLTZ matrices applying HPMCK4M, HPMC K100M and tragacanth could effectively extend the drug release. © Georg Thieme Verlag KG Stuttgart · New York.

  17. PHEBUS FP release analysis using a microstructure-based code

    International Nuclear Information System (INIS)

    Carlucci, L.N.

    1992-03-01

    The results of pre-test fission-product (FP) release analyses of the first two PHEBUS FP experiments, FPT0 and FPT1, indicate that the FREEDOM microstructure-based code predicts significant differences in both the timing and percent of gaseous FP releases for the two tests. To provide an indication of its predictive capability, FREEDOM was also used to model the high-burnup fuel tested in the Oak Ridge National Laboratory experiments VI-2 and VI-3. For these, the code was found to overpredict releases during the early stages of the tests and to underpredict releases during the later stages. The release kinetics in both tests were reasonably predicted, however. In view of the above, it is likely that the FREEDOM predictions of the final cumulative releases for the first two PHEBUS FP tests are lower-bound estimates. However, the significant difference in the predicted timing of initial releases for the two tests is felt to be indicative of what will occur. Therefore, this difference should be considered in the planning and conduct of the two tests, particularly aspects related to on-line measurements

  18. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    OpenAIRE

    Mingrong Zhang; Songhao Wang; Yu-Ching Yang

    2016-01-01

    The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-de...

  19. Effect of centrifugation time on growth factor and MMP release of an experimental platelet-rich fibrin-type product.

    Science.gov (United States)

    Eren, Gülnihal; Gürkan, Ali; Atmaca, Harika; Dönmez, Ayhan; Atilla, Gül

    2016-07-01

    Platelet-rich fibrin (PRF) has a controlled release of growth factors due to the fibrin matrix structure. Different centrifugation protocols were suggested for PRF preparation. Since the derivation method of PRF can alter its contents, in the present study it is aimed to investigate the cell contents and transforming growth factor beta-1 (TGF-β1), platelet-derived growth factor (PDGF-AB), vascular endothelial growth factor (VEGF), matrix metalloproteinase (MMP)-1 and-8 release from experimental PRF-type membranes obtained with different centrifugation times at 400 gravity. Three blood samples were collected from 20 healthy non-smoker volunteers. One tube was used for whole blood analyses. The other two tubes were centrifuged at 400 g for 10 minutes (group A) or 12 minutes (group B). Each experimental PRF-type membrane was placed in Dulbecco's Modified Eagle's Medium (DMEM)and at 1, 24 and 72 hours, TGF-β1, PDGF-AB, VEGF, MMP-1 and -8 release amounts were analysed by enzyme-linked immunosorbent assay (ELISA). The blood cell count of membranes was determined by subtracting plasma supernatant and red blood cell (RBC) mixture from the whole blood cell counts. At 72 hours, the VEGF level of group B was statistically higher than that of group A (p = 0.040). The centrifugation time was not found to influence the release of other growth factors, enzymes and cell counts. Within the limits of the present study, it might be suggested that centrifugation time at a constant gravity has a significant effect on the VEGF levels released from experimental PRF-type membrane. It can be concluded that due to the importance of VEGF in the tissue healing process, membranes obtained at 12-minute centrifugation time may show a superior potential in wound healing.

  20. Flash release an alternative for releasing complex MEMS devices

    NARCIS (Netherlands)

    Deladi, S.; Krijnen, Gijsbertus J.M.; Elwenspoek, Michael Curt

    2004-01-01

    A novel time-saving and cost-effective release technique has been developed and is described. The physical nature of the process is explained in combination with experimental observations. The results of the flash release process are compared with those of freeze-drying and supercritical CO2

  1. Three-dimensional, two-species magnetohydrodynamic studies of the early time behaviors of the Combined Release and Radiation Effects Satellite G2 barium release

    International Nuclear Information System (INIS)

    Xie, Lianghai; Li, Lei; Wang, Jingdong; Zhang, Yiteng

    2014-01-01

    We present a three-dimensional, two-species (Ba + and H + ) MHD model to study the early time behaviors of a barium release at about 1 R E like Combined Release and Radiation Effects Satellite G2, with emphasis placed on the three-dimensional evolution of the barium cloud and its effects on the ambient plasma environment. We find that the perturbations caused by the cloud are the combined results of the initial injection, the radial expansion, and the diamagnetic effect and propagate as fast MHD waves in the magnetosphere. In return, the transverse expansion and the cross-B motion of barium ions are constrained by the magnetic force, which lead to a field-aligned striation of ions and the decoupling of these ions from the neutrals. Our simulation shows the formation and collapse of the diamagnetic cavity in the barium cloud. The estimated time scale for the cavity evolution might be much shorter if photoionization time scale and field aligned expansion of barium ions are considered. In addition, our two species MHD simulation also finds the snowplow effect resulting from the momentum coupling between barium ions and background H + , which creates density hole and bumps in the background H + when barium ions expanding along the magnetic field lines

  2. Patient Satisfaction Is Associated With Time With Provider But Not Clinic Wait Time Among Orthopedic Patients.

    Science.gov (United States)

    Patterson, Brendan M; Eskildsen, Scott M; Clement, R Carter; Lin, Feng-Chang; Olcott, Christopher W; Del Gaizo, Daniel J; Tennant, Joshua N

    2017-01-01

    Clinic wait time is considered an important predictor of patient satisfaction. The goal of this study was to determine whether patient satisfaction among orthopedic patients is associated with clinic wait time and time with the provider. The authors prospectively enrolled 182 patients at their outpatient orthopedic clinic. Clinic wait time was defined as the time between patient check-in and being seen by the surgeon. Time spent with the provider was defined as the total time the patient spent in the examination room with the surgeon. The Consumer Assessment of Healthcare Providers and Systems survey was used to measure patient satisfaction. Factors associated with increased patient satisfaction included patient age and increased time with the surgeon (P=.024 and P=.037, respectively), but not clinic wait time (P=.625). Perceived wait time was subject to a high level of error, and most patients did not accurately report whether they had been waiting longer than 15 minutes to see a provider until they had waited at least 60 minutes (P=.007). If the results of the current study are generalizable, time with the surgeon is associated with patient satisfaction in orthopedic clinics, but wait time is not. Further, the study findings showed that patients in this setting did not have an accurate perception of actual wait time, with many patients underestimating the time they waited to see a provider. Thus, a potential strategy for improving patient satisfaction is to spend more time with each patient, even at the expense of increased wait time. [Orthopedics. 2017; 40(1):43-48.]. Copyright 2016, SLACK Incorporated.

  3. Dating gasoline releases using ground-water chemical analyses: Case studies

    International Nuclear Information System (INIS)

    Worthington, M.A.; Perez, E.J.

    1993-01-01

    This paper presents case studies where geochemical data were analyzed in spatial and temporal relation to documented gasoline releases at typical service station sites. In particular, the authors present ground-water analytical data for sites where (1) the date of the gasoline release is known with a good degree of confidence, (2) the release is confined to a relatively short period of time so as to be considered essentially instantaneous, (3) antecedent geochemical condition are known or can be reasonably expected to have been either unaffected by previous hydrocarbon impacts or minor in comparison to known release events, and (4) where geologic materials can be classified as to structure and composition. The authors' intent is to provide empirical data regarding the hydrogeological fate of certain gasoline components, namely the compounds benzene, toluene, ethylbenzene and xylene isomers (BTEX) and methyl-tertiary-butyl ether (MTBE). Particular emphasis is placed on analysis of gasoline weathering as a means of comparing releases in given hydrogeologic environments. Trends seen in a variety of comparative hydrocarbon compound ratios may provide a basis for evaluating relative release dates

  4. Savannah River release: test of the new ARAC capability

    International Nuclear Information System (INIS)

    Dickerson, M.H.

    1977-01-01

    Working jointly from opposite sides of the nation Lawrence Livermore Laboratory (LLL) and the Savannah River Laboratory (SRL) quickly assessed the consequences of an early-morning tritium release in May 1974 from the Savannah River Plant, in South Carolina. Measurements confirmed the accuracy of the LLL predictions. Due to the small quantity involved and to the release location (well within the plant confines), the release was not dangerous to the public. The emergency provided a dramatic test of procedures and capabilities of the new Atmospheric Release Advisory Capability (ARAC) center at Livermore, which was not yet operational, demonstrating the capacity for quick response, and the feasibility of real-time data acquisition and transmittal across the continent

  5. Analysis of drug effects on neurotransmitter release

    International Nuclear Information System (INIS)

    Rowell, P.; Garner, A.

    1986-01-01

    The release of neurotransmitter is routinely studied in a superfusion system in which serial samples are collected and the effects of drugs or other treatments on the amount of material in the superfusate is determined. With frequent sampling interval, this procedure provides a mechanism for dynamically characterizing the release process itself. Using automated data collection in conjunction with polyexponential computer analysis, the equation which describes the release process in each experiment is determined. Analysis of the data during the nontreated phase of the experiment allows an internal control to be used for accurately assessing any changes in neurotransmitter release which may occur during a subsequent treatment phase. The use of internal controls greatly improves the signal to noise ratio and allows determinations of very low concentrations of drugs on small amounts of tissue to be made. In this presentation, the effects of 10 μM nicotine on 3 H-dopamine release in rat nucleus accumbens is described. The time course, potency and efficacy of the drug treatment is characterized using this system. Determinations of the exponential order of the release as well as the rate constants allow one to study the mechanism of the release process. A description of 3 H-dopamine release in normal as well as Ca ++ -free medium is presented

  6. Opportunities and challenges of real-time release testing in biopharmaceutical manufacturing.

    Science.gov (United States)

    Jiang, Mo; Severson, Kristen A; Love, John Christopher; Madden, Helena; Swann, Patrick; Zang, Li; Braatz, Richard D

    2017-11-01

    Real-time release testing (RTRT) is defined as "the ability to evaluate and ensure the quality of in-process and/or final drug product based on process data, which typically includes a valid combination of measured material attributes and process controls" (ICH Q8[R2]). This article discusses sensors (process analytical technology, PAT) and control strategies that enable RTRT for the spectrum of critical quality attributes (CQAs) in biopharmaceutical manufacturing. Case studies from the small-molecule and biologic pharmaceutical industry are described to demonstrate how RTRT can be facilitated by integrated manufacturing and multivariable control strategies to ensure the quality of products. RTRT can enable increased assurance of product safety, efficacy, and quality-with improved productivity including faster release and potentially decreased costs-all of which improve the value to patients. To implement a complete RTRT solution, biologic drug manufacturers need to consider the special attributes of their industry, particularly sterility and the measurement of viral and microbial contamination. Continued advances in on-line and in-line sensor technologies are key for the biopharmaceutical manufacturing industry to achieve the potential of RTRT. Related article: http://onlinelibrary.wiley.com/doi/10.1002/bit.26378/full. © 2017 Wiley Periodicals, Inc.

  7. Investigation of delayed fission gas release

    International Nuclear Information System (INIS)

    Cayet, Nicolas

    1996-05-01

    The study of the fission gas release process in the high burnup rig IFA-562 has revealed a particular fuel behaviour: a delay in the fission gas release process. It appeared that an important release of gas was measured by the pressure transducers once the power had decreased, whereas, during steady-state operation, the pressure did not increase very much. After examinations, the gap size has been concluded to be the main parameter involving this delay. However the burnup could have been a potential factor, its role is mainly to close the gap by swelling. The observations of low burnup rods have shown the same delayed fission gas release, the gap being small by design and closed essentially by thermal expansion. The study of the kinetics has demonstrated the time-independency of the phenomenon. Thus the proposed mechanism driving this delayed fission gas release would involve three consecutives stages. During steady-state, the gas is released into the interlinkage network of grain boundary bubbles and cracks. Due to the closed gap, the gas is trapped in some void volumes, unable to escape the pellet. During power reduction, the gap and some old/new cracks open, immediately providing a path for the gas to the pressure transducers and explaining this delay in the fission gas release. (author)

  8. Development and evaluation of accelerated drug release testing methods for a matrix-type intravaginal ring.

    Science.gov (United States)

    Externbrink, Anna; Eggenreich, Karin; Eder, Simone; Mohr, Stefan; Nickisch, Klaus; Klein, Sandra

    2017-01-01

    Accelerated drug release testing is a valuable quality control tool for long-acting non-oral extended release formulations. Currently, several intravaginal ring candidates designed for the long-term delivery of steroids or anti-infective drugs are being in the developing pipeline. The present article addresses the demand for accelerated drug release methods for these formulations. We describe the development and evaluation of accelerated release methods for a steroid releasing matrix-type intravaginal ring. The drug release properties of the formulation were evaluated under real-time and accelerated test conditions. Under real-time test conditions drug release from the intravaginal ring was strongly affected by the steroid solubility in the release medium. Under sufficient sink conditions that were provided in release media containing surfactants drug release was Fickian diffusion driven. Both temperature and hydro-organic dissolution media were successfully employed to accelerate drug release from the formulation. Drug release could be further increased by combining the temperature effect with the application of a hydro-organic release medium. The formulation continued to exhibit a diffusion controlled release kinetic under the investigated accelerated conditions. Moreover, the accelerated methods were able to differentiate between different prototypes of the intravaginal ring that exhibited different release profiles under real-time test conditions. Overall, the results of the present study indicate that both temperature and hydro-organic release media are valid parameters for accelerating drug release from the intravaginal ring. Variation of either a single or both parameters yielded release profiles that correlated well with real-time release. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Evaluation of radioxenon releases in Australia using atmospheric dispersion modelling tools

    International Nuclear Information System (INIS)

    Tinker, Rick; Orr, Blake; Grzechnik, Marcus; Hoffmann, Emmy; Saey, Paul; Solomon, Stephen

    2010-01-01

    The origin of a series of atmospheric radioxenon events detected at the Comprehensive Test Ban Treaty Organisation (CTBTO) International Monitoring System site in Melbourne, Australia, between November 2008 and February 2009 was investigated. Backward tracking analyses indicated that the events were consistent with releases associated with hot commission testing of the Australian Nuclear Science Technology Organisation (ANSTO) radiopharmaceutical production facility in Sydney, Australia. Forward dispersion analyses were used to estimate release magnitudes and transport times. The estimated 133 Xe release magnitude of the largest event (between 0.2 and 34 TBq over a 2 d window), was in close agreement with the stack emission releases estimated by the facility for this time period (between 0.5 and 2 TBq). Modelling of irradiation conditions and theoretical radioxenon emission rates were undertaken and provided further evidence that the Melbourne detections originated from this radiopharmaceutical production facility. These findings do not have public health implications. This is the first comprehensive study of atmospheric radioxenon measurements and releases in Australia.

  10. Simulated atmospheric disperison of radioactive material released in an urban area

    International Nuclear Information System (INIS)

    Akins, R.E.; Church, H.W.; Tierney, M.S.

    1977-01-01

    A combination of Gaussian plume and particle-in-cell techniques is used to simulate the atmospheric transport and dispersion of a puff release of radioactive material. The release is caused by an accident that is assumed to occur during the shipment of the radioactive material through central New York City. The simulation provides estimates of volumetric and surface concentrations of the dispersed material that are used to predict radiation doses incurred by the City's population in the event of an accidental release. In the simulation, the release point is arbitrary and the material is assumed to be either a gas or fine particles. The Gaussian plume model follows cloud concentrations from the release time until times when transport over distances up to 500 m has been achieved. The released cloud may stabilize at street level or above the mean buildings height; at a street intersection or in the middle of the block. The possibility of the formation of multiple clouds, owing to circumstances of wind flow direction and street geometry, is allowed

  11. Apparatus for dynamic measurement of gases released from materials heated under programmed temperature-time control

    International Nuclear Information System (INIS)

    Early, J.W.; Abernathey, R.M.

    1982-04-01

    This apparatus, a prototype of one being constructed for hotcell examination of irradiated nuclear materials, measures dynamic release rates and integrated volumes of individual gases from materials heated under controlled temperature-time programs. It consists of an inductively heated vacuum furnace connected to a quadrupole mass spectrometer. A computerized control system with data acquisition provides scanning rates down to 1s and on-line tabular and graphic displays. Heating rates are up to 1300 0 C/min to a maximum temperature of 2000 0 C. The measurement range is about 10 -6 to 10 -2 torr-liter/s for H 2 , CH 4 , H 2 O, N 2 , and CO and 10 -8 to 10 -2 torr-liter/s for He, Kr, and Xe. Applications are described for measurements of Kr and Xe in mixed oxide fuel, various gases in UO 2 pellets, and He in 238 PuO 2 power and heat sources

  12. Release Early, Release Often: Predicting Change in Versioned Knowledge Organization Systems on the Web

    OpenAIRE

    Meroño-Peñuela, Albert; Guéret, Christophe; Schlobach, Stefan

    2015-01-01

    The Semantic Web is built on top of Knowledge Organization Systems (KOS) (vocabularies, ontologies, concept schemes) that provide a structured, interoperable and distributed access to Linked Data on the Web. The maintenance of these KOS over time has produced a number of KOS version chains: subsequent unique version identifiers to unique states of a KOS. However, the release of new KOS versions pose challenges to both KOS publishers and users. For publishers, updating a KOS is a knowledge int...

  13. A review of mathematical modeling and simulation of controlled-release fertilizers.

    Science.gov (United States)

    Irfan, Sayed Ameenuddin; Razali, Radzuan; KuShaari, KuZilati; Mansor, Nurlidia; Azeem, Babar; Ford Versypt, Ashlee N

    2018-02-10

    Nutrients released into soils from uncoated fertilizer granules are lost continuously due to volatilization, leaching, denitrification, and surface run-off. These issues have caused economic loss due to low nutrient absorption efficiency and environmental pollution due to hazardous emissions and water eutrophication. Controlled-release fertilizers (CRFs) can change the release kinetics of the fertilizer nutrients through an abatement strategy to offset these issues by providing the fertilizer content in synchrony with the metabolic needs of the plants. Parametric analysis of release characteristics of CRFs is of paramount importance for the design and development of new CRFs. However, the experimental approaches are not only time consuming, but they are also cumbersome and expensive. Scientists have introduced mathematical modeling techniques to predict the release of nutrients from the CRFs to elucidate fundamental understanding of the dynamics of the release processes and to design new CRFs in a shorter time and with relatively lower cost. This paper reviews and critically analyzes the latest developments in the mathematical modeling and simulation techniques that have been reported for the characteristics and mechanisms of nutrient release from CRFs. The scope of this review includes the modeling and simulations techniques used for coated, controlled-release fertilizers. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Time providing care outside visits in a home-based primary care program.

    Science.gov (United States)

    Pedowitz, Elizabeth J; Ornstein, Katherine A; Farber, Jeffrey; DeCherrie, Linda V

    2014-06-01

    To assess how much time physicians in a large home-based primary care (HBPC) program spend providing care outside of home visits. Unreimbursed time and patient and provider-related factors that may contribute to that time were considered. Mount Sinai Visiting Doctors (MSVD) providers filled out research forms for every interaction involving care provision outside of home visits. Data collected included length of interaction, mode, nature, and with whom the interaction was for 3 weeks. MSVD, an academic home-visit program in Manhattan, New York. All primary care physicians (PCPs) in MSVD (n = 14) agreed to participate. Time data were analyzed using a comprehensive estimate and conservative estimates to quantify unbillable time. Data on 1,151 interactions for 537 patients were collected. An average 8.2 h/wk was spent providing nonhome visit care for a full-time provider. Using the most conservative estimates, 3.6 h/wk was estimated to be unreimbursed per full-time provider. No significant differences in interaction times were found between patients with and without dementia, new and established patients, and primary-panel and covered patients. Home-based primary care providers spend substantial time providing care outside home visits, much of which goes unrecognized in the current reimbursement system. These findings may help guide practice development and creation of new payment systems for HBPC and similar models of care. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  15. Pollutant Release and Transfer Register

    International Nuclear Information System (INIS)

    2008-01-01

    Since 1974 a number of organisations have been working closely together in this pollutant register (PRTR) project to collect and formally establish the yearly releases of pollutants to air, water and soil in the Netherlands. Results of this project serve to underpin the national environmental policy. Data is in this way also provided for the many environmental reports to international organisations such as the European Union and the United Nations, e.g. the National Inventory Report for the Kyoto Protocol. This website shows the yearly releases (emissions) of the most important pollutants in the Netherlands. You can explore the emission data through various channels, such as maps, graphs and tables. But you can also download all the details into your own database. The data shown in this website is updated 2 to 3 times a year. The current release shows emissions for 1990, 1995, 2000, 2004, 2005 and 2006 The 2006 emissions are preliminary data and not yet shown in the maps. We expect to add an extra year in August 2008 [nl

  16. Designing Process Improvement of Finished Good On Time Release and Performance Indicator Tool in Milk Industry Using Business Process Reengineering Method

    Science.gov (United States)

    Dachyar, M.; Christy, E.

    2014-04-01

    To maintain position as a major milk producer, the Indonesian milk industry should do some business development with the purpose of increasing customer service level. One strategy is to create on time release conditions for finished goods which will be distributed to customers and distributors. To achieve this condition, management information systems of finished goods on time release needs to be improved. The focus of this research is to conduct business process improvement using Business Process Reengineering (BPR). The deliverable key of this study is a comprehensive business strategy which is the solution of the root problems. To achieve the goal, evaluation, reengineering, and improvement of the ERP system are conducted. To visualize the predicted implementation, a simulation model is built by Oracle BPM. The output of this simulation showed that the proposed solution could effectively reduce the process lead time and increase the number of quality releases.

  17. Ultrasound enhanced release of therapeutics from drug-releasing implants based on titania nanotube arrays.

    Science.gov (United States)

    Aw, Moom Sinn; Losic, Dusan

    2013-02-25

    A non-invasive and external stimulus-driven local drug delivery system (DDS) based on titania nanotube (TNT) arrays loaded with drug encapsulated polymeric micelles as drug carriers and ultrasound generator is described. Ultrasound waves (USW) generated by a pulsating sonication probe (Sonotrode) in phosphate buffered saline (PBS) at pH 7.2 as the medium for transmitting pressure waves, were used to release drug-loaded nano-carriers from the TNT arrays. It was demonstrated that a very rapid release in pulsatile mode can be achieved, controlled by several parameters on the ultrasonic generator. This includes pulse length, time, amplitude and power intensity. By optimization of these parameters, an immediate drug-micelles release of 100% that spans a desirable time of 5-50 min was achieved. It was shown that stimulated release can be generated and reproduced at any time throughout the TNT-Ti implant life, suggesting considerable potential of this approach as a feasible and tunable ultrasound-mediated drug delivery system in situ via drug-releasing implants. It is expected that this concept can be translated from an in vitro to in vivo regime for therapeutic applications using drug-releasing implants in orthopedic and coronary stents. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  18. Real time in vitro studies of doxorubicin release from PHEMA nanoparticles

    Directory of Open Access Journals (Sweden)

    Bajpai AK

    2009-10-01

    Full Text Available Abstract Background Many anticancer agents have poor water solubility and therefore the development of novel delivery systems for such molecules has received significant attention. Nanocarriers show great potential in delivering therapeutic agents into the targeted organs or cells and have recently emerged as a promising approach to cancer treatments. The aim of this study was to prepare and use poly-2-hydroxyethyl methacrylate (PHEMA nanoparticles for the controlled release of the anticancer drug doxorubicin. Results PHEMA nanoparticles have been synthesized and characterized using FTIR and scanning electron microscopy (SEM, particle size analysis and surface charge measurements. We also studied the effects of various parameters such as percent loading of drugs, chemical architecture of the nanocarriers, pH, temperature and nature of the release media on the release profiles of the drug. The chemical stability of doxorubicin in PBS was assessed at a range of pH. Conclusion Suspension polymerization of 2-hydroxyethyl methacrylate (HEMA results in the formation of swellable nanoparticles of defined composition. PHEMA nanoparticles can potentially be used for the controlled release of the anticancer drug doxorubicin.

  19. Statistical Optimization of Sustained Release Venlafaxine HCI Wax Matrix Tablet.

    Science.gov (United States)

    Bhalekar, M R; Madgulkar, A R; Sheladiya, D D; Kshirsagar, S J; Wable, N D; Desale, S S

    2008-01-01

    The purpose of this research was to prepare a sustained release drug delivery system of venlafaxine hydrochloride by using a wax matrix system. The effects of bees wax and carnauba wax on drug release profile was investigated. A 3(2) full factorial design was applied to systemically optimize the drug release profile. Amounts of carnauba wax (X(1)) and bees wax (X(2)) were selected as independent variables and release after 12 h and time required for 50% (t(50)) drug release were selected as dependent variables. A mathematical model was generated for each response parameter. Both waxes retarded release after 12 h and increases the t(50) but bees wax showed significant influence. The drug release pattern for all the formulation combinations was found to be approaching Peppas kinetic model. Suitable combination of two waxes provided fairly good regulated release profile. The response surfaces and contour plots for each response parameter are presented for further interpretation of the results. The optimum formulations were chosen and their predicted results found to be in close agreement with experimental findings.

  20. Nanomedicine for glaucoma: liposomes provide sustained release of latanoprost in the eye

    Directory of Open Access Journals (Sweden)

    Natarajan JV

    2012-01-01

    Full Text Available Jayaganesh V Natarajan1*, Marcus Ang2*, Anastasia Darwitan1, Sujay Chattopadhyay3, Tina T Wong2, Subbu S Venkatraman1 1Materials Science and Engineering, Nanyang Technological University, Singapore; 2Singapore Eye Research Institute, Singapore; 3Polymer Division, Indian Institute of Technology Roorkee, India*These authors contributed equally to this workPurpose: To report the development and therapeutic evaluation of a liposomal nanocarrier for sustained release of latanoprost, in the rabbit eye.Methods: We fabricated latanoprost-loaded egg-phosphatidylcholine (EggPC liposomes using the film hydration technique. The delivery vehicles were nano-sized (Z avg = 109 ± 18 nm, had a narrow poly dispersity index (PDI = 0.19 ± 0.04, and a very high loading efficiency (94% ± 5%. Based on in vitro data, we evaluated this formulation for lowering intraocular pressure (IOP in rabbit eyes. Following a single subconjunctival injection of the latanoprost loaded formulation, the eyes were clinically monitored and the IOP recorded.Results: Latanoprost-loaded EggPC liposomes demonstrated a high drug/lipid mole ratio of 0.181, remained stable for at least 6 months on storage (4°C, and at least 1 month at 25°C. A slow and sustained release of 60% of latanoprost was achieved by 14 days in the in vitro release study. The same formulation demonstrated a greater sustained IOP lowering effect compared with daily administration of topical latanoprost beyond 90 days (4.8 ± 1.5 vs 2.5 ± 0.9 mmHg; P < 0.001. No signs of inflammation were evident in the eyes from slit-lamp examination analysis.Conclusion: The loading required for a long-term sustained delivery of latanoprost for up to 90 days in the rabbit eyes was achieved with EggPC liposomes. A single injection of latanoprost-loaded EggPC liposomes can lower the IOP for up to 90 days, with a greater IOP lowering effect than daily topical administration of latanoprost.Keywords: nanomedicine, nanoliposomes, Egg

  1. Effect of in ovo injection of corticotropin-releasing hormone on the timing of hatching in broiler chickens.

    Science.gov (United States)

    Watanabe, Yugo; Grommen, Sylvia V H; De Groef, Bert

    2017-09-01

    In chicken embryos, intravenous injection of corticotropin-releasing hormone (CRH) causes the release of both corticosteroids and thyroid hormones. These hormones initiate and enhance the hatching process, raising the possibility that CRH treatment of the late chicken embryo could accelerate hatching and/or decrease the spread of hatching. We performed a series of exploratory tests to investigate whether in ovo delivery methods of CRH other than intravenous injection that are more practical in a commercial setting, affect hatching time in broilers. Corticotropin-releasing hormone was injected into the air cell, albumen, or amniotic fluid of broiler breeder eggs, in the last week of embryonic development. Average incubation duration was significantly decreased by 22 h when 2 μg of CRH was injected into the air cell on embryonic day 18 (E18) of Cobb eggs. Acceleration of hatching (but only by 8 h) was also seen for Ross chicks when CRH was injected daily into the albumen between E10 and E18. However, repeats of both experiments did not show consistent effects of CRH on hatching time; in most experiments performed, CRH did not affect hatching time. We speculate that the effectiveness of CRH uptake via these delivery methods and/or the duration and magnitude of the thyroxine and corticosterone response to CRH is not sufficient to have a substantial effect on hatching time. We therefore conclude that in ovo CRH treatment does not seem a feasible option as a practical tool to increase hatchery productivity or to investigate the effects of CRH agonists and antagonists on hatching. © 2017 Poultry Science Association Inc.

  2. Solvent-free biodegradable scleral plugs providing sustained release of vancomycin, amikacin, and dexamethasone--an in vivo study.

    Science.gov (United States)

    Peng, Yi-Jie; Kau, Yi-Chuan; Wen, Chin-Wei; Liu, Kuo-Sheng; Liu, Shih-Jung

    2010-08-01

    Delivering effective drugs at sufficiently high concentrations to the area of infection is a standard treatment for infectious disease, such as endophthalmitis. This is currently done by empirical trans pars plana intravitreal injection of both antibiotics directed against gram-positive and gram-negative microorganisms and steroids. However, injections by needles repeatedly may increase the risks of intraocular infection and hemorrhage, as well as retinal detachment. This article explores the alternative of using biodegradable polymers as scleral plugs for a long-term drug release in vivo. To manufacture plugs, poly(lactide-glycolide) copolymers were first mixed with vancomycin, amikacin, and dexamethasone. The mixture was compressed and sintered at 55 degrees C to form scleral plugs 1.4 mm in diameter. Biodegradable scleral plugs released high concentrations of antibiotics (well above the minimum inhibitory concentrations, MIC) and steroids in vivo for the period of time needed to treat intraocular infection. In addition, no major complications such as infectious or sterile endophthalmitis, retinal detachment, ocular phthisis, or uvea protrusion at sclerotomy site were observed throughout the experiment. The sclerotomy wound healed after total degradation of the scleral implants without leakage or local necrosis. Antibiotic/steroid-impregnated biodegradable scleral plugs may have a potential role in the treatment of various intraocular infections. (c) 2010 Wiley Periodicals, Inc.

  3. Estimating the location and spatial extent of a covert anthrax release.

    Directory of Open Access Journals (Sweden)

    Judith Legrand

    2009-01-01

    Full Text Available Rapidly identifying the features of a covert release of an agent such as anthrax could help to inform the planning of public health mitigation strategies. Previous studies have sought to estimate the time and size of a bioterror attack based on the symptomatic onset dates of early cases. We extend the scope of these methods by proposing a method for characterizing the time, strength, and also the location of an aerosolized pathogen release. A back-calculation method is developed allowing the characterization of the release based on the data on the first few observed cases of the subsequent outbreak, meteorological data, population densities, and data on population travel patterns. We evaluate this method on small simulated anthrax outbreaks (about 25-35 cases and show that it could date and localize a release after a few cases have been observed, although misspecifications of the spore dispersion model, or the within-host dynamics model, on which the method relies can bias the estimates. Our method could also provide an estimate of the outbreak's geographical extent and, as a consequence, could help to identify populations at risk and, therefore, requiring prophylactic treatment. Our analysis demonstrates that while estimates based on the first ten or 15 observed cases were more accurate and less sensitive to model misspecifications than those based on five cases, overall mortality is minimized by targeting prophylactic treatment early on the basis of estimates made using data on the first five cases. The method we propose could provide early estimates of the time, strength, and location of an aerosolized anthrax release and the geographical extent of the subsequent outbreak. In addition, estimates of release features could be used to parameterize more detailed models allowing the simulation of control strategies and intervention logistics.

  4. Time-integrated thyroid dose for accidental releases from Pakistan Research Reactor-1

    International Nuclear Information System (INIS)

    Raza, S Shoaib; Iqbal, M; Salahuddin, A; Avila, R; Pervez, S

    2004-01-01

    The two-hourly time-integrated thyroid dose due to radio-iodines released to the atmosphere through the exhaust stack of Pakistan Research Reactor-1 (PARR-1), under accident conditions, has been calculated. A computer program, PAKRAD (which was developed under an IAEA research grant, PAK/RCA/8990), was used for the dose calculations. The sensitivity of the dose results to different exhaust flow rates and atmospheric stability classes was studied. The effect of assuming a constant activity concentration (as a function of time) within the containment air volume and an exponentially decreasing air concentration on the time-integrated dose was also studied for various flow rates (1000-50,000 m 3 h -1 ). The comparison indicated that the results were insensitive to the containment air exhaust rates up to or below 2000 m 3 h -1 , when the prediction with the constant activity concentration assumption was compared to an exponentially decreasing activity concentration model. The results also indicated that the plume touchdown distance increases with increasing atmospheric stability. (note)

  5. Fission-product energy release for times following thermal-neutron fission of 235U between 2 and 14000 seconds

    International Nuclear Information System (INIS)

    Dickens, J.K.; Emery, J.F.; Love, T.A.; McConnell, J.W.; Northcutt, K.J.; Peelle, R.W.; Weaver, H.

    1977-10-01

    Fission-product decay energy-releases rates were measured for thermal-neutron fission of 235 U. Samples of mass 1 to 10 μg were irradiated for 1 to 100 sec by use of the fast pneumatic-tube facility at the Oak Ridge Research Reactor. The resulting beta- and gamma-ray emissions were counted for times-after-fission between 2 and 14,000 seconds. The data were obtained for beta and gamma rays separately as spectral distributions, N(E/sub γ/) vs E/sub γ/ and N(E/sub beta/) vs E/sub β/. For the gamma-ray data the spectra were obtained by using a NaI detector, while for the beta-ray data the spectra were obtained by using an NE-110 detector with an anticoincidence mantle. The raw data were unfolded to provide spectral distributions of modest resolution. These were integrated over E/sub γ/ and E/sub β/ to provide total yield and energy integrals as a function of time after fission. Results are low compared to the present 1973 ANS Decay-heat standard. A complete description of the experimental apparatus and data-reduction techniques is presented. The final integral data are given in tabular and graphical form and are compared with published data. 41 figures, 13 tables

  6. The ATP hydrolysis and phosphate release steps control the time course of force development in rabbit skeletal muscle.

    Science.gov (United States)

    Sleep, John; Irving, Malcolm; Burton, Kevin

    2005-03-15

    The time course of isometric force development following photolytic release of ATP in the presence of Ca(2+) was characterized in single skinned fibres from rabbit psoas muscle. Pre-photolysis force was minimized using apyrase to remove contaminating ATP and ADP. After the initial force rise induced by ATP release, a rapid shortening ramp terminated by a step stretch to the original length was imposed, and the time course of the subsequent force redevelopment was again characterized. Force development after ATP release was accurately described by a lag phase followed by one or two exponential components. At 20 degrees C, the lag was 5.6 +/- 0.4 ms (s.e.m., n = 11), and the force rise was well fitted by a single exponential with rate constant 71 +/- 4 s(-1). Force redevelopment after shortening-restretch began from about half the plateau force level, and its single-exponential rate constant was 68 +/- 3 s(-1), very similar to that following ATP release. When fibres were activated by the addition of Ca(2+) in ATP-containing solution, force developed more slowly, and the rate constant for force redevelopment following shortening-restretch reached a maximum value of 38 +/- 4 s(-1) (n = 6) after about 6 s of activation. This lower value may be associated with progressive sarcomere disorder at elevated temperature. Force development following ATP release was much slower at 5 degrees C than at 20 degrees C. The rate constant of a single-exponential fit to the force rise was 4.3 +/- 0.4 s(-1) (n = 22), and this was again similar to that after shortening-restretch in the same activation at this temperature, 3.8 +/- 0.2 s(-1). We conclude that force development after ATP release and shortening-restretch are controlled by the same steps in the actin-myosin ATPase cycle. The present results and much previous work on mechanical-chemical coupling in muscle can be explained by a kinetic scheme in which force is generated by a rapid conformational change bracketed by two

  7. Multimodal sensory integration during sequential eating--linking chewing activity, aroma release, and aroma perception over time.

    Science.gov (United States)

    Leclercq, Ségolène; Blancher, Guillaume

    2012-10-01

    The respective effects of chewing activity, aroma release from a gelled candy, and aroma perception were investigated. Specifically, the study aimed at 1) comparing an imposed chewing and swallowing pattern (IP) and free protocol (FP) on panelists for in vivo measurements, 2) investigating carryover effects in sequential eating, and 3) studying the link between instrumental data and their perception counterpart. Chewing activity, in-nose aroma concentration, and aroma perception over time were measured by electromyography, proton transfer reaction-mass spectrometry, and time intensity, respectively. Model gel candies were flavored at 2 intensity levels (low-L and high-H). The panelists evaluated 3 sequences (H then H, H then L, and L then H) in duplicates with both IP and FP. They scored aroma intensity over time while their in-nose aroma concentrations and their chewing activity were measured. Overall, only limited advantages were found in imposing a chewing and swallowing pattern for instrumental and sensory data. In addition, the study highlighted the role of brain integration on perceived intensity and dynamics of perception, in the framework of sequential eating without rinsing. Because of the presence of adaptation phenomena, contrast effect, and potential taste and texture cross-modal interaction with aroma perception, it was concluded that dynamic in-nose concentration data provide only one part of the perception picture and therefore cannot be used alone in prediction models.

  8. Heat release, time required, and cleaning ability of MTwo R and ProTaper universal retreatment systems in the removal of filling material.

    Science.gov (United States)

    Bramante, Clovis Monteiro; Fidelis, Natasha Siqueira; Assumpção, Tatiana Santos; Bernardineli, Norberti; Garcia, Roberto Brandão; Bramante, Alexandre Silva; de Moraes, Ivaldo Gomes

    2010-11-01

    This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 °C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, α = 0.05). None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Music therapy with imminently dying hospice patients and their families: facilitating release near the time of death.

    Science.gov (United States)

    Krout, Robert E

    2003-01-01

    Hospice care seeks to address the diverse needs of terminally ill patients in a number of physical, psychosocial, and spiritual areas. Family members of the patient often are included in the care and services provided by the hospice team, and hospice clinicians face a special challenge when working with families of patients who are imminently dying. When loved ones are anticipating the patient's impending death, they may find it difficult to express feelings, thoughts, and last wishes. Music therapy is a service modality that can help to facilitate such communication between the family and the patient who is actively dying, while also providing a comforting presence. Music therapy as a way to ease communication and sharing between dying patients and their loved ones is discussed in this article. The ways in which music therapy can facilitate a means of release for both patients and family members in an acute care unit of a large US hospice organization are specifically described. Case descriptions illustrate how music therapy functioned to allow five patients and their families to both come together and let go near the time of death. Elements to consider when providing such services to imminently dying patients and their families are discussed.

  10. Guidance for Evaluating the Safety of Experimental Releases of Mosquitoes, Emphasizing Mark-Release-Recapture Techniques.

    Science.gov (United States)

    Benedict, Mark Q; Charlwood, J Derek; Harrington, Laura C; Lounibos, L Philip; Reisen, William K; Tabachnick, Walter J

    2018-01-01

    Experimental releases of mosquitoes are performed to understand characteristics of populations related to the biology, ability to transmit pathogens, and ultimately their control. In this article, we discuss considerations related to the safety of experimental releases of living mosquitoes, applying principles of good practice in vector biology that protect human health and comfort. We describe specific factors of experimental releases of mosquitoes that we believe are critical to inform institutional biosafety committees and similar review boards to which proposals to conduct mosquito release experiments have been submitted. In this study, "experimental releases" means those that do not significantly increase vector capacity or nuisance biting relative to the unperturbed natural baseline. This document specifically does not address releases of mosquitoes for ongoing control programs or trials of new control methods for which broader assessments of risk are required. It also does not address releases of transgenic or exotic (non-native) mosquito species, both of which require particular regulatory approval. Experimental releases may include females and males and evaluation must consider their effects based on the number released, their genotype and phenotype, the environment into which they are released, and postrelease collection activities. We consider whether increases of disease transmission and nuisance biting might result from proposed experimental releases against the backdrop of natural population size variation. We recommend that experimental releases be conducted in a manner that can be reasonably argued to have insignificant negative effects. Reviewers of proposals for experimental releases should expect applicants to provide such an argument based on evidence from similar studies and their planned activities. This document provides guidance for creating and evaluating such proposals.

  11. Environmental releases for calendar year 1996

    International Nuclear Information System (INIS)

    Greager, E.M.

    1997-01-01

    This report presents data on radioactive and nonradioactive materials released into the environment during calendar year 1996 from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (formerly the Westinghouse Hanford Company) and Bechtel Hanford, Incorporated. Fluor Daniel Hanford, Incorporated provides effluent monitoring services for Bechtel Hanford, Incorporated, which includes release reporting. Both summary and detailed presentations of the environmental releases are provided. When appropriate, comparisons to data from previous years are made

  12. Environmental releases for calendar year 1996

    Energy Technology Data Exchange (ETDEWEB)

    Greager, E.M.

    1997-07-31

    This report presents data on radioactive and nonradioactive materials released into the environment during calendar year 1996 from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (formerly the Westinghouse Hanford Company) and Bechtel Hanford, Incorporated. Fluor Daniel Hanford, Incorporated provides effluent monitoring services for Bechtel Hanford, Incorporated, which includes release reporting. Both summary and detailed presentations of the environmental releases are provided. When appropriate, comparisons to data from previous years are made.

  13. In vitro studies of copper release from powder particles in synthetic biological media

    International Nuclear Information System (INIS)

    Midander, Klara; Wallinder, Inger Odnevall; Leygraf, Christofer

    2007-01-01

    The aim of this paper is to provide quantitative data on copper release from powder particles of different copper materials, including artificial copper patina, Cu 2 O and metallic Cu, when exposed to different synthetic biological media to simulate an inhalation scenario and/or skin contact. Generated data may contribute in risk assessment of potential health effects following exposure to and handling of various copper materials. All tests were performed in vitro to determine total copper concentrations, release rates of total copper, and to elucidate its time-dependence. The copper release process was interpreted in terms of specific surface area, surface morphology-, and composition. All powder materials show a time-dependent release process with total copper release rates less than 3 μg/cm 2 per hour at steady state conditions, for all media investigated. The importance of using relevant test media when simulating different interstitial lung conditions and difficulties encountered when comparing powder particles of essentially different properties are thoroughly discussed. - Copper release rates from particles are essential to assess potential health aspects

  14. Modelling vesicular release at hippocampal synapses.

    Directory of Open Access Journals (Sweden)

    Suhita Nadkarni

    2010-11-01

    Full Text Available We study local calcium dynamics leading to a vesicle fusion in a stochastic, and spatially explicit, biophysical model of the CA3-CA1 presynaptic bouton. The kinetic model for vesicle release has two calcium sensors, a sensor for fast synchronous release that lasts a few tens of milliseconds and a separate sensor for slow asynchronous release that lasts a few hundred milliseconds. A wide range of data can be accounted for consistently only when a refractory period lasting a few milliseconds between releases is included. The inclusion of a second sensor for asynchronous release with a slow unbinding site, and thereby a long memory, affects short-term plasticity by facilitating release. Our simulations also reveal a third time scale of vesicle release that is correlated with the stimulus and is distinct from the fast and the slow releases. In these detailed Monte Carlo simulations all three time scales of vesicle release are insensitive to the spatial details of the synaptic ultrastructure. Furthermore, our simulations allow us to identify features of synaptic transmission that are universal and those that are modulated by structure.

  15. Dose rates as a function of time due to postulated radionuclide releases from the U.S. Yucca Mountain high-level radioactive waste repository

    International Nuclear Information System (INIS)

    Moeller, Dade W.; Sun, Lin-Shen C.; Cherry, Robert

    2008-01-01

    The Yucca Mountain repository, which is located in a remote area in the State of Nevada, is being constructed for the long-term care and disposal of spent nuclear fuel and vitrified high-level radioactive waste. In accordance with U.S. law, the U.S. Environmental Protection Agency (USEPA) promulgated Standards that limit the dose rates to members of the public due to the consumption of ground water, alone, and the consumption of ground water plus agricultural products irrigated with the contaminated ground water, and other exposures, such as those from external sources and the inhalation of airborne radioactive materials. As part of this exercise, the USEPA identified eight specific radionuclides to which their Standards are to apply. These are: 14 C, 99 Tc, 129 I, 226 Ra, 228 Ra, 237 Np, 239 Pu, and 241 Am. For purposes of the associated dose rate estimates, a range of conservative assumptions have been applied, all of which are designed to assure that the estimated dose rates are well above what might be expected under 'real-world' conditions. As a first step, it was assumed that: (1) at 10 4 year after repository closure, a fractional release of 10 -5 of the entire repository radionuclide inventory occurred; (2) the only prior reduction in the inventory was that due to radioactive decay; and (3) the sole path of exposure to neighboring population groups was through the consumption of 2 L d -1 of contaminated ground water. The accompanying analyses revealed that, of the eight radionuclides, only 226 Ra, 237 Np, and 239 Pu, will represent a significant source of dose at that time. To provide perspective and insights, the next step was to estimate the committed effective dose rates for all eight radionuclides based on an assumed fractional release each year of 10 -5 of the inventory from the time of repository closure up through the 10 6 year. For purposes of providing perspective, it was assumed that each dose rate estimate was independent, that is, no releases

  16. A New Application of Lipid Nanoemulsions as Coating Agent, Providing Zero-Order Hydrophilic Drug Release from Tablets

    Directory of Open Access Journals (Sweden)

    Nicolas Anton

    2012-01-01

    Full Text Available The objective of the present investigation was to evaluate potential of nanoemulsions as a coating material for the tablets. The nanoemulsion of size less than 100 nm was prepared using a simple and low-energy spontaneous emulsification method. Conventional tablets containing theophylline as a model hydrophilic drug were prepared. The theophylline tablets were coated with the nanoemulsion using a fluid bed coater. The effect of different levels of the nanoemulsion coating on the theophylline release was evaluated. The theophylline tablets containing different levels of the nanoemulsion coating could be successfully prepared. Interestingly, the coating of tablet with the nanoemulsion resulted in zero-order release of theophylline from the tablets. The noncoated theophylline tablets release the entire drug in less than 2 minutes, whereas nanoemulsion coating delayed the release of theophylline from tablets. This investigation establishes the proof of concept for the potential of nanoemulsions as a coating material for tablets.

  17. Allegheny County Toxics Release Inventory

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Toxics Release Inventory (TRI) data provides information about toxic substances released into the environment or managed through recycling, energy recovery, and...

  18. Accelerating protein release from microparticles for regenerative medicine applications

    Energy Technology Data Exchange (ETDEWEB)

    White, Lisa J., E-mail: lisa.white@nottingham.ac.uk; Kirby, Giles T.S.; Cox, Helen C.; Qodratnama, Roozbeh; Qutachi, Omar; Rose, Felicity R.A.J.; Shakesheff, Kevin M.

    2013-07-01

    There is a need to control the spatio-temporal release kinetics of growth factors in order to mitigate current usage of high doses. A novel delivery system, capable of providing both structural support and controlled release kinetics, has been developed from PLGA microparticles. The inclusion of a hydrophilic PLGA–PEG–PLGA triblock copolymer altered release kinetics such that they were decoupled from polymer degradation. A quasi zero order release profile over four weeks was produced using 10% w/w PLGA–PEG–PLGA with 50:50 PLGA whereas complete and sustained release was achieved over ten days using 30% w/w PLGA–PEG–PLGA with 85:15 PLGA and over four days using 30% w/w PLGA–PEG–PLGA with 50:50 PLGA. These three formulations are promising candidates for delivery of growth factors such as BMP-2, PDGF and VEGF. Release profiles were also modified by mixing microparticles of two different formulations providing another route, not previously reported, for controlling release kinetics. This system provides customisable, localised and controlled delivery with adjustable release profiles, which will improve the efficacy and safety of recombinant growth factor delivery. Highlights: ► A new delivery system providing controlled release kinetics has been developed. ► Inclusion of hydrophilic PLGA–PEG–PLGA decoupled release kinetics from degradation. ► Using 10% triblock copolymer produced quasi zero order release over four weeks. ► Mixing microparticle formulations provided another route for controlling release. ► This system provides customisable, localised and controlled delivery of growth factors.

  19. Improved cortisol exposure-time profile and outcome in patients with adrenal insufficiency: a prospective randomized trial of a novel hydrocortisone dual-release formulation.

    Science.gov (United States)

    Johannsson, G; Nilsson, A G; Bergthorsdottir, R; Burman, P; Dahlqvist, P; Ekman, B; Engström, B E; Olsson, T; Ragnarsson, O; Ryberg, M; Wahlberg, J; Biller, B M K; Monson, J P; Stewart, P M; Lennernäs, H; Skrtic, S

    2012-02-01

    Patients with treated adrenal insufficiency (AI) have increased morbidity and mortality rate. Our goal was to improve outcome by developing a once-daily (OD) oral hydrocortisone dual-release tablet with a more physiological exposure-time cortisol profile. The aim was to compare pharmacokinetics and metabolic outcome between OD and the same daily dose of thrice-daily (TID) dose of conventional hydrocortisone tablets. We conducted an open, randomized, two-period, 12-wk crossover multicenter trial with a 24-wk extension at five university hospital centers. The trial enrolled 64 adults with primary AI; 11 had concomitant diabetes mellitus (DM). The same daily dose of hydrocortisone was administered as OD dual-release or TID. We evaluated cortisol pharmacokinetics. Compared with conventional TID, OD provided a sustained serum cortisol profile 0-4 h after the morning intake and reduced the late afternoon and the 24-h cortisol exposure. The mean weight (difference = -0.7 kg, P = 0.005), systolic blood pressure (difference = -5.5 mm Hg, P = 0.0001) and diastolic blood pressure (difference: -2.3 mm Hg; P = 0.03), and glycated hemoglobin (absolute difference = -0.1%, P = 0.0006) were all reduced after OD compared with TID at 12 wk. Compared with TID, a reduction in glycated hemoglobin by 0.6% was observed in patients with concomitant DM during OD (P = 0.004). The OD dual-release tablet provided a more circadian-based serum cortisol profile. Reduced body weight, reduced blood pressure, and improved glucose metabolism were observed during OD treatment. In particular, glucose metabolism improved in patients with concomitant DM.

  20. Aluminum corrosion product release kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Matt, E-mail: Matthew.Edwards@cnl.ca; Semmler, Jaleh; Guzonas, Dave; Chen, Hui Qun; Toor, Arshad; Hoendermis, Seanna

    2015-07-15

    Highlights: • Release of Al corrosion product was measured in simulated post-LOCA sump solutions. • Increased boron was found to enhance Al release kinetics at similar pH. • Models of Al release as functions of time, temperature, and pH were developed. - Abstract: The kinetics of aluminum corrosion product release was examined in solutions representative of post-LOCA sump water for both pressurized water and pressurized heavy-water reactors. Coupons of AA 6061 T6 were exposed to solutions in the pH 7–11 range at 40, 60, 90 and 130 °C. Solution samples were analyzed by inductively coupled plasma atomic emission spectroscopy, and coupon samples were analyzed by secondary ion mass spectrometry. The results show a distinct “boron effect” on the release kinetics, expected to be caused by an increase in the solubility of the aluminum corrosion products. New models were developed to describe both sets of data as functions of temperature, time, and pH (where applicable)

  1. Massive radiological releases profoundly differ from controlled releases

    International Nuclear Information System (INIS)

    Pascucci-Cahen, Ludivine; Patrick, Momal

    2012-11-01

    Preparing for a nuclear accident implies understanding potential consequences. While many specialized experts have been working on different particular aspects, surprisingly little effort has been dedicated to establishing the big picture and providing a global and balanced image of all major consequences. IRSN has been working on the cost of nuclear accidents, an exercise which must strive to be as comprehensive as possible since any omission obviously underestimates the cost. It therefore provides (ideally) an estimate of all cost components, thus revealing the structure of accident costs, and hence sketching a global picture. On a French PWR, it appears that controlled releases would cause an 'economical' accident with limited radiological consequences when compared to other costs; in contrast, massive releases would trigger a major crisis with strong radiological consequences. The two types of crises would confront managers with different types of challenges. (authors)

  2. Modelling and assessment of accidental oil release from damaged subsea pipelines.

    Science.gov (United States)

    Li, Xinhong; Chen, Guoming; Zhu, Hongwei

    2017-10-15

    This paper develops a 3D, transient, mathematical model to estimate the oil release rate and simulate the oil dispersion behavior. The Euler-Euler method is used to estimate the subsea oil release rate, while the Eulerian-Lagrangian method is employed to track the migration trajectory of oil droplets. This model accounts for the quantitative effect of backpressure and hole size on oil release rate, and the influence of oil release rate, oil density, current speed, water depth and leakage position on oil migration is also investigated in this paper. Eventually, the results, e.g. transient release rate of oil, the rise time of oil and dispersion distance are determined by above-mentioned model, and the oil release and dispersion behavior under different scenarios is revealed. Essentially, the assessment results could provide a useful guidance for detection of leakage positon and placement of oil containment boom. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Performance and first results of fission product release and transport provided by the VERDON facility

    Energy Technology Data Exchange (ETDEWEB)

    Gallais-During, A., E-mail: annelise.gallais-during@cea.fr [CEA, DEN, DEC, F-13108 Saint-Paul-lez-Durance (France); Bonnin, J.; Malgouyres, P.-P. [CEA, DEN, DEC, F-13108 Saint-Paul-lez-Durance (France); Morin, S. [IRSN, F-13108 Saint-Paul-lez-Durance (France); Bernard, S.; Gleizes, B.; Pontillon, Y.; Hanus, E.; Ducros, G. [CEA, DEN, DEC, F-13108 Saint-Paul-lez-Durance (France)

    2014-10-01

    Highlights: • A new facility to perform experimental LWR severe accidents sequences is evaluated. • In the furnace a fuel sample is heated up to 2600 °C under a controlled gas atmosphere. • Innovative thermal gradient tubes are used to study fission product transport. • The new VERDON facility shows an excellent consistency with results from VERCORS. • Fission product re-vapourization results confirm the correct functioning of the gradient tubes. - Abstract: One of the most important areas of research concerning a hypothetical severe accident in a light water reactor (LWR) is determining the source term, i.e. quantifying the nature, release kinetics and global released fraction of the fission products (FPs) and other radioactive materials. In line with the former VERCORS programme to improve source term estimates, the new VERDON laboratory has recently been implemented at the CEA Cadarache Centre in the LECA-STAR facility. The present paper deals with the evaluation of the experimental equipment of this new VERDON laboratory (furnace, release and transport loops) and demonstrates its capability to perform experimental sequences representative of LWR severe accidents and to supply the databases necessary for source term assessments and FP behaviour modelling.

  4. Release of DNA from polyelectrolyte multilayers fabricated using 'charge-shifting' cationic polymers: tunable temporal control and sequential, multi-agent release.

    Science.gov (United States)

    Sun, Bin; Lynn, David M

    2010-11-20

    promote the sequential release of two different DNA constructs with separate and distinct release profiles (e.g., the release of a first construct over a period of ~3 days, followed by the sustained release of a second for a period of ~70 days). With further development, this approach could contribute to the design of functional thin films and surface coatings that provide sophisticated control over the timing and the order of the release of two or more DNA constructs (or other agents) of interest in a range of biomedical contexts. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Intelligibility and Clarity of Reverberant Speech: Effects of Wide Dynamic Range Compression Release Time and Working Memory

    Science.gov (United States)

    Reinhart, Paul N.; Souza, Pamela E.

    2016-01-01

    Purpose: The purpose of this study was to examine the effects of varying wide dynamic range compression (WDRC) release time on intelligibility and clarity of reverberant speech. The study also considered the role of individual working memory. Method: Thirty older listeners with mild to moderately-severe sloping sensorineural hearing loss…

  6. Controlled release systems containing solid dispersions: strategies and mechanisms.

    Science.gov (United States)

    Tran, Phuong Ha-Lien; Tran, Thao Truong-Dinh; Park, Jun Bom; Lee, Beom-Jin

    2011-10-01

    In addition to a number of highly soluble drugs, most new chemical entities under development are poorly water-soluble drugs generally characterized by an insufficient dissolution rate and a small absorption window, leading to the low bioavailability. Controlled-release (CR) formulations have several potential advantages over conventional dosage forms, such as providing a uniform and prolonged therapeutic effect to improve patient compliance, reducing the frequency of dosing, minimizing the number of side effects, and reducing the strength of the required dose while increasing the effectiveness of the drug. Solid dispersions (SD) can be used to enhance the dissolution rate of poorly water-soluble drugs and to sustain the drug release by choosing an appropriate carrier. Thus, a CR-SD comprises both functions of SD and CR for poorly water-soluble drugs. Such CR dosage forms containing SD provide an immediately available dose for an immediate action followed by a gradual and continuous release of subsequent doses to maintain the plasma concentration of poorly water-soluble drugs over an extended period of time. This review aims to summarize all currently known aspects of controlled release systems containing solid dispersions, focusing on the preparation methods, mechanisms of action and characterization of physicochemical properties of the system.

  7. Deployable Plume and Aerosol Release Prediction and Tracking System. Nuclear Non-Proliferation Task 1. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Kleppe, John; Norris, William; Etezadi, Mehdi

    2006-07-19

    This contract was awarded in response to a proposal in which a deployable plume and aerosol release prediction and tracking system would be designed, fabricated, and tested. The system would gather real time atmospheric data and input it into a real time atmospheric model that could be used for plume predition and tracking. The system would be able to be quickly deployed by aircraft to points of interest or positioned for deployment by vehicles. The system would provide three dimensional (u, v, and w) wind vector data, inversion height measurements, surface wind information, classical weather station data, and solar radiation. The on-board real time computer model would provide the prediction of the behavior of plumes and released aerosols.

  8. 131I release from a HTGR during the LOFC accident

    International Nuclear Information System (INIS)

    Foley, J.E.

    1975-03-01

    The time-dependent release of 131 I from both the core and the containment building of a high temperature gas-cooled (HTGR) reactor during the loss of forced coolant (LOFC) accident is studied. A simplified core release model is combined with a containment building release model so that the total amount of the isotope released to the environment can be calculated. The time-dependent release of 131 I from the core during the LOFC accident is primarily a function of the time-dependent core temperatures and the failed fuel release constants. The most important factor in calculating the amount of the isotope released to the environment is the total amount released into the containment building. (U.S.)

  9. Real time imaging of live cell ATP leaking or release events by chemiluminescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yun [Iowa State Univ., Ames, IA (United States)

    2008-12-18

    The purpose of this research was to expand the chemiluminescence microscopy applications in live bacterial/mammalian cell imaging and to improve the detection sensitivity for ATP leaking or release events. We first demonstrated that chemiluminescence (CL) imaging can be used to interrogate single bacterial cells. While using a luminometer allows detecting ATP from cell lysate extracted from at least 10 bacterial cells, all previous cell CL detection never reached this sensitivity of single bacteria level. We approached this goal with a different strategy from before: instead of breaking bacterial cell membrane and trying to capture the transiently diluted ATP with the firefly luciferase CL assay, we introduced the firefly luciferase enzyme into bacteria using the modern genetic techniques and placed the CL reaction substrate D-luciferin outside the cells. By damaging the cell membrane with various antibacterial drugs including antibiotics such as Penicillins and bacteriophages, the D-luciferin molecules diffused inside the cell and initiated the reaction that produces CL light. As firefly luciferases are large protein molecules which are retained within the cells before the total rupture and intracellular ATP concentration is high at the millmolar level, the CL reaction of firefly luciferase, ATP and D-luciferin can be kept for a relatively long time within the cells acting as a reaction container to generate enough photons for detection by the extremely sensitive intensified charge coupled device (ICCD) camera. The result was inspiring as various single bacterium lysis and leakage events were monitored with 10-s temporal resolution movies. We also found a new way of enhancing diffusion D-luciferin into cells by dehydrating the bacteria. Then we started with this novel single bacterial CL imaging technique, and applied it for quantifying gene expression levels from individual bacterial cells. Previous published result in single cell gene expression quantification

  10. [3H]Serotonin release: an improved method to measure mast cell degranulation

    International Nuclear Information System (INIS)

    Mazingue, C.; Dessaint, J.-P.; Capron, A.

    1978-01-01

    A method based on the release of tritium-labelled serotonin by activated mast cells in rodents is described. Mast cells incorporate labelled serotonin selectively and released the label after activation by non-specific stimulators (compound 48/80, polymyxin B sulphate, ATP, bovine chymotrypsin and L-α-lysophosphatidylcholine) or anaphylactic antibody and the corresponding antigen. These two types of activation were investigated in comparison with the toluidine blue microscopic rat mast cell degranulation test, and a methodological study of the release of [ 3 H] serotonin is described. The measurement of labelled serotonin release provides a simple and quick assay of mast cell degranulation compared to the time required for the classical rat mast cell degranulation technique and achieves a greater sensitivity. (Auth.)

  11. Press Oil Final Release Survey

    Energy Technology Data Exchange (ETDEWEB)

    Whicker, Jeffrey Jay [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ruedig, Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-11

    There are forty-eight 55 gallon barrels filled with hydraulic oil that are candidates for release and recycle. This oil needs to be characterized prior to release. Principles of sampling as provided in MARSAME/MARSSIM approaches were used as guidance for sampling.

  12. Corrosion Tests of LWR Fuels - Nuclide Release

    International Nuclear Information System (INIS)

    P.A. Finn; Y. Tsai; J.C. Cunnane

    2001-01-01

    Two BWR fuels [64 and 71 (MWd)/kgU], one of which contained 2% Gd, and two PWR fuels [30 and 45 (MWd)/kgU], are tested by dripping groundwater on the fuels under oxidizing and hydrologically unsaturated conditions for times ranging from 2.4 to 8.2 yr at 90 C. The 99 Tc, 129 I, 137 Cs, 97 Mo, and 90 Sr releases are presented to show the effects of long reaction times and of gadolinium on nuclide release. This investigation showed that the five nuclides at long reaction times have similar fractional release rates and that the presence of 2% Gd reduced the 99 Tc cumulative release fraction by about an order of magnitude over that of a fuel with a similar burnup

  13. Sterile insect supply, emergence, and release

    International Nuclear Information System (INIS)

    Dowell, R.V.; Worley, J.; Gomes, P.J.

    2005-01-01

    Insect mass-rearing for a sterile insect technique (SIT) programme is designed to move beyond the large-scale rearing of insects in a laboratory to the industrial production of consistently high-quality insects for sterilization and release. Each facility reflects the unique biology of the insect reared within it, but there are some generalities for all rearing facilities. Rearing insects in self-contained modules offers flexibility, and increased safety from catastrophic occurrences, compared with using a single building which houses all facets of the rearing process. Although mechanizing certain aspects of the rearing steps helps provide a consistently high-quality insect, successful mass-rearing and delivery depends largely upon the human component. Besides production in centralized facilities, insects can be produced from purchased eggs, or nowadays, adult insects are often obtained from specialized satellite emergence/collection facilities. Interest in commercializing insect production and release is increasing. Shipping sterile insects, sometimes over long distances, is now common practice. Procedures for handling and chilling adult insects, and providing food and water prior to release, are continually being improved. Sterile insects are released via static-release receptacles, ground-release systems, or most commonly from the air. The aerial release of chilled sterile insects is the most efficient method of release, especially when aircraft flight paths are guided by a Global Positioning System (GPS) linked to a computer-controlled release mechanism. (author)

  14. Radionuclide releases to the atmosphere from Hanford Operations, 1944--1972. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Heeb, C.M.

    1994-05-01

    The purpose of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation dose that individuals could have received as a result of radionuclide emissions since 1944 from the Hanford Site. The first step in determining dose is to estimate the amount and timing of radionuclide releases to air and water. This report provides the air release information.

  15. Analysis of in-pile tritium release experiments

    International Nuclear Information System (INIS)

    Kopasz, J.P.; Tam, S.W.; Johnson, C.E.

    1992-01-01

    The objective of this work is to characterize tritium release behavior from lithium ceramics and develop insight into the underlying tritium release mechanisms. Analysis of tritium release data from recent laboratory experiments with lithium aluminate has identified physical processes which were previously unaccounted for in tritium release models. A new model that incorporates the recent data and provides for release from multiple sites rather than only one site was developed. Calculations of tritium release using this model are in excellent agreement with the tritium release behavior reported for the MOZART experiment

  16. Research and development of controlled release technology for agrochemicals using isotopes

    International Nuclear Information System (INIS)

    1986-01-01

    In recent years, increasing investment has been made into development of measures to reduce pesticide contamination of food and the environment while at the same time protecting crops and livestock from pest attack. Studies to develop controlled-release technology are frequently carried out with labelled compounds. Radiotracer techniques provide a unique tool in measuring the release rate of the chemical, the stability of the chemical within the formulation and evaluating the effect of environmental factors on the release rate. These technologies and pesticide residue problems were the theme of the Seminar. The Seminar has illustrated the potential value of isotope techniques and has reviewed information on current developments in this field and their relevance to agriculture in developing countries

  17. Device provides controlled gas leaks

    Science.gov (United States)

    Kami, S. K.; King, H. J.

    1968-01-01

    Modified palladium leak device provides a controlled release /leak/ of very small quantities of gas at low or medium pressures. It has no moving parts, requires less than 5 watts to operate, and is capable of releasing the gas either continuously or in pulses at adjustable flow rates.

  18. Sustained release of antibiotics from injectable and thermally responsive polypeptide depots.

    Science.gov (United States)

    Adams, Samuel B; Shamji, Mohammed F; Nettles, Dana L; Hwang, Priscilla; Setton, Lori A

    2009-07-01

    Biodegradable polymeric scaffolds are of interest for delivering antibiotics to local sites of infection in orthopaedic applications, such as bone and diarthrodial joints. The objective of this study was to develop a biodegradable scaffold with ease of drug loading in aqueous solution, while providing for drug depot delivery via syringe injection. Elastin-like polypeptides (ELPs) were used for this application, biopolymers of repeating pentapeptide sequences that were thermally triggered to undergo in situ depot formation at body temperature. ELPs were modified to enable loading with the antibiotics, cefazolin, and vancomycin, followed by induction of the phase transition in vitro. Cefazolin and vancomycin concentrations were monitored, as well as bioactivity of the released antibiotics, to test an ability of the ELP depot to provide for prolonged release of bioactive drugs. Further tests of formulation viscosity were conducted to test suitability as an injectable drug carrier. Results demonstrate sustained release of therapeutic concentrations of bioactive antibiotics by the ELP, with first-order time constants for drug release of approximately 25 h for cefazolin and approximately 500 h for vancomycin. These findings illustrate that an injectable, in situ forming ELP depot can provide for sustained release of antibiotics with an effect that varies across antibiotic formulation. ELPs have important advantages for drug delivery, as they are known to be biocompatible, biodegradable, and elicit no known immune response. These benefits suggest distinct advantages over currently used carriers for antibiotic drug delivery in orthopedic applications. (c) 2008 Wiley Periodicals, Inc.

  19. PAVAN, Atmospheric Dispersion of Radioactive Releases from Nuclear Power Plants

    International Nuclear Information System (INIS)

    2001-01-01

    1 - Description of program or function: PAVAN estimates down-wind ground-level air concentrations for potential accidental releases of radioactive material from nuclear facilities. Options can account for variation in the location of release points, additional plume dispersion due to building wakes, plume meander under low wind speed conditions, and adjustments to consider non-straight trajectories. It computes an effective plume height using the physical release height which can be reduced by inputted terrain features. 2 - Method of solution: Using joint frequency distributions of wind direction and wind speed by atmospheric stability, the program provides relative air concentration (X/Q) values as functions of direction for various time periods at the exclusion area boundary (EAB) and the outer boundary of the low population zone (LPZ). Calculations of X/Q values can be made for assumed ground-level releases or evaluated releases from free-standing stacks. The X/Q calculations are based on the theory that material released to the atmosphere will be normally distributed (Gaussian) about the plume centerline. A straight-line trajectory is assumed between the point of release and all distances for which X/Q values are calculated. 3 - Restrictions on the complexity of the problem: - The code cannot handle multiple emission sources

  20. Residence time of contaminants released in surface coal mines -- a wind-tunnel study

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, R.S. [Environmental Protection Agency, Research Triangle Park, NC (United States)

    1994-12-31

    Surface coal mining operations (blasting, shoveling, loading, trucking, etc.) are sources of airborne particles. The 1990 Clean Air Act Amendments direct the EPA to analyze the accuracy of the Industrial Source Complex model and the AP-42 emission factors, and to make revisions as may be necessary to eliminate any significant over-prediction of air concentration of fugitive particles from surface coal mines. A wind-tunnel study was performed at the US EPA`s Fluid Modeling Facility to investigate dispersion from surface coal mines in support of the dispersion modeling activities. Described here is the portion of the study directed at determining the residence time that material released near the floor of a mine will stay within the mine.

  1. RAVEN Beta Release

    International Nuclear Information System (INIS)

    Rabiti, Cristian; Alfonsi, Andrea; Cogliati, Joshua Joseph; Mandelli, Diego; Kinoshita, Robert Arthur; Wang, Congjian; Maljovec, Daniel Patrick; Talbot, Paul William

    2016-01-01

    This documents the release of the Risk Analysis Virtual Environment (RAVEN) code. A description of the RAVEN code is provided, and discussion of the release process for the M2LW-16IN0704045 milestone. The RAVEN code is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN has now increased in maturity enough for the Beta 1.0 release.

  2. RAVEN Beta Release

    Energy Technology Data Exchange (ETDEWEB)

    Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cogliati, Joshua Joseph [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mandelli, Diego [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kinoshita, Robert Arthur [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wang, Congjian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Maljovec, Daniel Patrick [Idaho National Lab. (INL), Idaho Falls, ID (United States); Talbot, Paul William [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This documents the release of the Risk Analysis Virtual Environment (RAVEN) code. A description of the RAVEN code is provided, and discussion of the release process for the M2LW-16IN0704045 milestone. The RAVEN code is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN has now increased in maturity enough for the Beta 1.0 release.

  3. Nanoscale distribution of presynaptic Ca(2+) channels and its impact on vesicular release during development.

    Science.gov (United States)

    Nakamura, Yukihiro; Harada, Harumi; Kamasawa, Naomi; Matsui, Ko; Rothman, Jason S; Shigemoto, Ryuichi; Silver, R Angus; DiGregorio, David A; Takahashi, Tomoyuki

    2015-01-07

    Synaptic efficacy and precision are influenced by the coupling of voltage-gated Ca(2+) channels (VGCCs) to vesicles. But because the topography of VGCCs and their proximity to vesicles is unknown, a quantitative understanding of the determinants of vesicular release at nanometer scale is lacking. To investigate this, we combined freeze-fracture replica immunogold labeling of Cav2.1 channels, local [Ca(2+)] imaging, and patch pipette perfusion of EGTA at the calyx of Held. Between postnatal day 7 and 21, VGCCs formed variable sized clusters and vesicular release became less sensitive to EGTA, whereas fixed Ca(2+) buffer properties remained constant. Experimentally constrained reaction-diffusion simulations suggest that Ca(2+) sensors for vesicular release are located at the perimeter of VGCC clusters (<30 nm) and predict that VGCC number per cluster determines vesicular release probability without altering release time course. This "perimeter release model" provides a unifying framework accounting for developmental changes in both synaptic efficacy and time course. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. TOXRISK, Toxic Gas Release Accident Analysis

    International Nuclear Information System (INIS)

    Bennett, D.E.; Chanin, D.I.; Shiver, A.W.

    1993-01-01

    1 - Description of program or function: TOXRISK is an interactive program developed to aid in the evaluation of nuclear power plant control room habitability in the event of a nearby toxic material release. The program uses a model which is consistent with the approach described in the NRC Regulatory Guide 1.78. Release of the gas is treated as an initial puff followed by a continuous plume. The relative proportions of these as well as the plume release rate are supplied by the user. Transport of the gas is modeled as a Gaussian distribution and occurs through the action of a constant velocity, constant direction wind. Great flexibility is afforded the user in specifying the release description, meteorological conditions, relative geometry of the accident and plant, and the plant ventilation system characteristics. Two types of simulation can be performed: multiple case (parametric) studies and probabilistic analyses. Upon execution, TOXRISK presents a menu, and the user chooses between the Data Base Manager, the Multiple Case program, and the Probabilistic Study Program. The Data Base Manager provides a convenient means of storing, retrieving, and modifying blocks of data required by the analysis programs. The Multiple Case program calculates resultant gas concentrations inside the control room and presents a summary of information that describes the event for each set of conditions given. Optimally, a time history profile of inside and outside concentrations can also be produced. The Probabilistic Study program provides a means for estimating the annual probability of operator incapacitation due to toxic gas accidents on surrounding transportation routes and storage sites. 2 - Method of solution: Dispersion or diffusion of the gas during transport is described by modified Pasquill-Gifford dispersion coefficients

  5. Pharmacokinetics of prolonged-release tacrolimus and implications for use in solid organ transplant recipients.

    Science.gov (United States)

    Tanzi, Maria G; Undre, Nasrullah; Keirns, James; Fitzsimmons, William E; Brown, Malcolm; First, M Roy

    2016-08-01

    Prolonged-release tacrolimus was developed as a once-daily formulation with ethylcellulose as the excipient, resulting in slower release and reduction in peak concentration (Cmax ) for a given dose compared with immediate-release tacrolimus, which is administered twice daily. This manuscript reviews pharmacokinetic information on prolonged-release tacrolimus in healthy subjects, in transplant recipients converted from immediate-release tacrolimus, and in de novo kidney and liver transplant recipients. As with the immediate-release formulation, prolonged-release tacrolimus shows a strong correlation between trough concentration (Cmin ) and area under the 24-hour time-concentration curve (AUC24 ), indicating that trough whole blood concentrations provide an accurate measure of drug exposure. We present the pharmacokinetic similarities and differences between the two formulations, so that prescribing physicians will have a better understanding of therapeutic drug monitoring in patients receiving prolonged-release tacrolimus. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Workload Control with Continuous Release

    NARCIS (Netherlands)

    Phan, B. S. Nguyen; Land, M. J.; Gaalman, G. J. C.

    2009-01-01

    Workload Control (WLC) is a production planning and control concept which is suitable for the needs of make-to-order job shops. Release decisions based on the workload norms form the core of the concept. This paper develops continuous time WLC release variants and investigates their due date

  7. Near-infrared remotely triggered drug-release strategies for cancer treatment

    Science.gov (United States)

    Goodman, Amanda M.; Neumann, Oara; Nørregaard, Kamilla; Henderson, Luke; Choi, Mi-Ran; Clare, Susan E.; Halas, Naomi J.

    2017-11-01

    Remotely controlled, localized drug delivery is highly desirable for potentially minimizing the systemic toxicity induced by the administration of typically hydrophobic chemotherapy drugs by conventional means. Nanoparticle-based drug delivery systems provide a highly promising approach for localized drug delivery, and are an emerging field of interest in cancer treatment. Here, we demonstrate near-IR light-triggered release of two drug molecules from both DNA-based and protein-based hosts that have been conjugated to near-infrared-absorbing Au nanoshells (SiO2 core, Au shell), each forming a light-responsive drug delivery complex. We show that, depending upon the drug molecule, the type of host molecule, and the laser illumination method (continuous wave or pulsed laser), in vitro light-triggered release can be achieved with both types of nanoparticle-based complexes. Two breast cancer drugs, docetaxel and HER2-targeted lapatinib, were delivered to MDA-MB-231 and SKBR3 (overexpressing HER2) breast cancer cells and compared with release in noncancerous RAW 264.7 macrophage cells. Continuous wave laser-induced release of docetaxel from a nanoshell-based DNA host complex showed increased cell death, which also coincided with nonspecific cell death from photothermal heating. Using a femtosecond pulsed laser, lapatinib release from a nanoshell-based human serum albumin protein host complex resulted in increased cancerous cell death while noncancerous control cells were unaffected. Both methods provide spatially and temporally localized drug-release strategies that can facilitate high local concentrations of chemotherapy drugs deliverable at a specific treatment site over a specific time window, with the potential for greatly minimized side effects.

  8. Hypsometric Amplification of Greenland Ice Sheet Meltwater Release

    Science.gov (United States)

    van As, D.; Hasholt, B.; Mikkelsen, A. B.; Holtegaard Nielsen, M.; Box, J.; Claesson Liljedahl, L.; Lindback, K.; Pitcher, L. H.

    2017-12-01

    Proglacial discharge monitoring provides valuable insights in Greenland ice sheet meltwater release. We use a 2006-2016 discharge time series from the Watson River draining 12000 km2 of the ice sheet in southwest Greenland to investigate the large variability in catchment-total meltwater production. An observationally-constrained reconstruction of past discharge shows that meltwater release has on average increased by a factor of 1.5 since 2003 compared to the 1949-2002 period, and that interannual variability has disproportionally increased by a factor of 2.1, suggesting that melt amplifiers are at play. We derive a hypsometric amplification factor of 1.6, which is the result of the exponential melt area increase with rising temperature. Peak meltwater discharge events such as during the July 2012 flooding are due to this and other melt amplifiers, but also require intense melting over a period exceeding the multi-day transit time for high-elevation meltwater to pass through the glacial drainage system.

  9. Kinetics of drug release from ointments: Role of transient-boundary layer.

    Science.gov (United States)

    Xu, Xiaoming; Al-Ghabeish, Manar; Krishnaiah, Yellela S R; Rahman, Ziyaur; Khan, Mansoor A

    2015-10-15

    In the current work, an in vitro release testing method suitable for ointment formulations was developed using acyclovir as a model drug. Release studies were carried out using enhancer cells on acyclovir ointments prepared with oleaginous, absorption, and water-soluble bases. Kinetics and mechanism of drug release was found to be highly dependent on the type of ointment bases. In oleaginous bases, drug release followed a unique logarithmic-time dependent profile; in both absorption and water-soluble bases, drug release exhibited linearity with respect to square root of time (Higuchi model) albeit differences in the overall release profile. To help understand the underlying cause of logarithmic-time dependency of drug release, a novel transient-boundary hypothesis was proposed, verified, and compared to Higuchi theory. Furthermore, impact of drug solubility (under various pH conditions) and temperature on drug release were assessed. Additionally, conditions under which deviations from logarithmic-time drug release kinetics occur were determined using in situ UV fiber-optics. Overall, the results suggest that for oleaginous ointments containing dispersed drug particles, kinetics and mechanism of drug release is controlled by expansion of transient boundary layer, and drug release increases linearly with respect to logarithmic time. Published by Elsevier B.V.

  10. Optimal Release Time and Sensitivity Analysis Using a New NHPP Software Reliability Model with Probability of Fault Removal Subject to Operating Environments

    Directory of Open Access Journals (Sweden)

    Kwang Yoon Song

    2018-05-01

    Full Text Available With the latest technological developments, the software industry is at the center of the fourth industrial revolution. In today’s complex and rapidly changing environment, where software applications must be developed quickly and easily, software must be focused on rapidly changing information technology. The basic goal of software engineering is to produce high-quality software at low cost. However, because of the complexity of software systems, software development can be time consuming and expensive. Software reliability models (SRMs are used to estimate and predict the reliability, number of remaining faults, failure intensity, total and development cost, etc., of software. Additionally, it is very important to decide when, how, and at what cost to release the software to users. In this study, we propose a new nonhomogeneous Poisson process (NHPP SRM with a fault detection rate function affected by the probability of fault removal on failure subject to operating environments and discuss the optimal release time and software reliability with the new NHPP SRM. The example results show a good fit to the proposed model, and we propose an optimal release time for a given change in the proposed model.

  11. Mechanical properties and modeling of drug release from chlorhexidine-containing etch-and-rinse adhesives.

    Science.gov (United States)

    Stanislawczuk, Rodrigo; Reis, Alessandra; Malaquias, Pamela; Pereira, Fabiane; Farago, Paulo Vitor; Meier, Marcia Margarete; Loguercio, Alessandro D

    2014-04-01

    To evaluate the effects of chlorhexidine (CHX) addition in different concentrations into simplified etch-and-rinse adhesives on the ultimate tensile strength (UTS), water sorption (WS), solubility (SO) and the rate of CHX release over time. We added CHX diacetate to Ambar [AM] (FGM) and XP Bond [XP] (Dentsply) in concentrations of 0, 0.01, 0.05, 0.1 and 0.2 wt%. For UTS (n=10 for each group), adhesive specimens were constructed in an hourglass shape metallic matrix with cross-sectional area of 0.8 mm(2). Half of specimens were tested after 24 h and the other half after 28 days of water storage in tension of 0.5 mm/min. For WS and SO (n=10 for each group), adhesive discs (5.8 mm×1.0 mm) were prepared into a mold. After desiccation, we weighed and stored the cured adhesive specimens in distilled water for evaluation of the WS, SO and the cumulative release of CHX over a 28-day period. For CHX release (n=10 for each group), spectrophotometric measurements of storage solution were performed to examine the release kinetics of CHX. We subjected data from each test to ANOVA and Tukey' test (α=0.05). XP Bond adhesive showed significantly more WS and SO and lower UTS than Ambar. In general, the addition of CHX did not alter WS, SO and UTS of the adhesives. XP showed a higher CHX release than AM (p<0.05) in all concentrations and the final amount of CHX release was directly proportional to the initial CHX concentration added to the adhesives. After 28 days of water storage, approximately 20% of CHX was released from XP and 8.0-12.0% from AM. Addition of CHX to commercial adhesive is a feasible method to provide a controlled release of CHX over time without jeopardizing WS, SO and UTS of the adhesives. Manufacturers should consider adding CHX to commercial adhesives to provide a controlled release of CHX over time. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Toxic releases from power plants

    International Nuclear Information System (INIS)

    Rubin, E.S.

    1999-01-01

    Beginning in 1998, electric power plants burning coal or oil must estimate and report their annual releases of toxic chemicals listed in the Toxics Release Inventory (TRI) published by the US Environmental Protection Agency (EPA). This paper identifies the toxic chemicals of greatest significance for the electric utility sector and develops quantitative estimates of the toxic releases reportable to the TRI for a representative coal-fired power plant. Key factors affecting the magnitude and types of toxic releases for individual power plants also are discussed. A national projection suggests that the magnitude of electric utility industry releases will surpass those of the manufacturing industries which current report to the TRI. Risk communication activities at the community level will be essential to interpret and provide context for the new TRI results

  13. The influence of source term release parameters on health effects

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Ha, Jae Joo

    1998-08-01

    In this study, the influence of source term release parameters on the health effects was examined. This is very useful in identifying the relative importance of release parameters and can be an important factor in developing a strategy for reducing offsite risks. The release parameters investigated in this study are release height, heat content, fuel burnup, release time, release duration, and warning time. The health effects affected by the change of release parameters are early fatalities, cancer fatalities, early injuries, cancer injuries, early fatality risk, population weighted early fatality risk, population weighted cancer fatality risk, effective whole body population dose, population exceeding an early acute red bone marrow dose of 1.5 Sv, and distance at which early fatalities are expected to occur. As release height increases, the values of early health effects such as early fatalities and injuries decrease. However, the release height dose not have significant influences on late health effects. The values of both early and late health effects decrease as heat content increases. The increase fuel burnup, i.e., the increase of core inventories increases the late health effects, however, has small influence on the early health effects. But, the number of early injuries increases as the fuel burnup increases. The effects of release time increase shows very similar influence on both the early and late health effects. As the release time increases to 2 hours, the values of health effects increase and then decrease rapidly. As release duration increases, the values of late health effects increase slightly, however, the values of early health effects decrease. As warning time increases to 2 hours, the values of late health effects decrease and then shows no variation. The number of early injuries decreases rapidly as the warning time increases to 2 hours. However, the number of early fatalities and the early fatality risk increase as the warning time increases

  14. Classification of H2O2 as a Neuromodulator that Regulates Striatal Dopamine Release on a Subsecond Time Scale

    Science.gov (United States)

    2012-01-01

    Here we review evidence that the reactive oxygen species, hydrogen peroxide (H2O2), meets the criteria for classification as a neuromodulator through its effects on striatal dopamine (DA) release. This evidence was obtained using fast-scan cyclic voltammetry to detect evoked DA release in striatal slices, along with whole-cell and fluorescence imaging to monitor cellular activity and H2O2 generation in striatal medium spiny neurons (MSNs). The data show that (1) exogenous H2O2 suppresses DA release in dorsal striatum and nucleus accumbens shell and the same effect is seen with elevation of endogenous H2O2 levels; (2) H2O2 is generated downstream from glutamatergic AMPA receptor activation in MSNs, but not DA axons; (3) generation of modulatory H2O2 is activity dependent; (4) H2O2 generated in MSNs diffuses to DA axons to cause transient DA release suppression by activating ATP-sensitive K+ (KATP) channels on DA axons; and (5) the amplitude of H2O2-dependent inhibition of DA release is attenuated by enzymatic degradation of H2O2, but the subsecond time course is determined by H2O2 diffusion rate and/or KATP-channel kinetics. In the dorsal striatum, neuromodulatory H2O2 is an intermediate in the regulation of DA release by the classical neurotransmitters glutamate and GABA, as well as other neuromodulators, including cannabinoids. However, modulatory actions of H2O2 occur in other regions and cell types, as well, consistent with the widespread expression of KATP and other H2O2-sensitive channels throughout the CNS. PMID:23259034

  15. A multifunctional multimaterial system for on-demand protein release.

    Science.gov (United States)

    Tuncaboylu, Deniz Ceylan; Friess, Fabian; Wischke, Christian; Lendlein, Andreas

    2018-06-15

    In order to provide best control of the regeneration process for each individual patient, the release of protein drugs administered during surgery may need to be timely adapted and/or delayed according to the progress of healing/regeneration. This study aims to establish a multifunctional implant system for a local on-demand release, which is applicable for various types of proteins. It was hypothesized that a tubular multimaterial container kit, which hosts the protein of interest as a solution or gel formulation, would enable on-demand release if equipped with the capacity of diameter reduction upon external stimulation. Using devices from poly(ɛ-caprolactone) networks, it could be demonstrated that a shape-memory effect activated by heat or NIR light enabled on-demand tube shrinkage. The decrease of diameter of these shape-memory tubes (SMT) allowed expelling the payload as demonstrated for several proteins including SDF-1α, a therapeutically relevant chemotactic protein, to achieve e.g. continuous release with a triggered add-on dosing (open tube) or an on-demand onset of bolus or sustained release (sealed tube). Considering the clinical relevance of protein factors in (stem) cell attraction to lesions and the progress in monitoring biomarkers in body fluids, such on-demand release systems may be further explored e.g. in heart, nerve, or bone regeneration in the future. Copyright © 2018. Published by Elsevier B.V.

  16. Quantifying Ca2+ release and inactivation of Ca2+ release in fast- and slow-twitch muscles.

    Science.gov (United States)

    Barclay, C J

    2012-12-01

    The aims of this study were to quantify the Ca(2+) release underlying twitch contractions of mammalian fast- and slow-twitch muscle and to comprehensively describe the transient inactivation of Ca(2+) release following a stimulus. Experiments were performed using bundles of fibres from mouse extensor digitorum longus (EDL) and soleus muscles. Ca(2+) release was quantified from the amount of ATP used to remove Ca(2+) from the myoplasm following stimulation. ATP turnover by crossbridges was blocked pharmacologically (N-benzyl-p-toluenesulphonamide for EDL, blebbistatin for soleus) and muscle heat production was used as an index of Ca(2+) pump ATP turnover. At 20°C, Ca(2+) release in response to a single stimulus was 34 and 84 μmol (kg muscle)(-1) for soleus and EDL, respectively, and increased with temperature (30°C: soleus, 61 μmol kg(-1); EDL, 168 μmol kg(-1)). Delivery of another stimulus within 100 ms of the first produced a smaller Ca(2+) release. The maximum magnitude of the decrease in Ca(2+) release was greater in EDL than soleus. Ca(2+) release recovered with an exponential time course which was faster in EDL (mean time constant at 20°C, 32.1 ms) than soleus (65.6 ms) and faster at 30°C than at 20°C. The amounts of Ca(2+) released and crossbridge cycles performed are consistent with a scheme in which Ca(2+) binding to troponin-C allowed an average of ∼1.7 crossbridge cycles in the two muscles.

  17. Encapsulation of naproxen in lipid-based matrix microspheres: characterization and release kinetics.

    Science.gov (United States)

    Bhoyar, P K; Morani, D O; Biyani, D M; Umekar, M J; Mahure, J G; Amgaonkar, Y M

    2011-04-01

    The objective of this study was to microencapsulate the anti-inflammatory drug (naproxen) to provide controlled release and minimizing or eliminating local side effect by avoiding the drug release in the upper gastrointestinal track. Naproxen was microencapsulated with lipid-like carnauba wax, hydrogenated castor oil using modified melt dispersion (modified congealable disperse phase encapsulation) technique. Effect of various formulation and process variables such as drug-lipid ratio, concentration of modifier, concentration of dispersant, stirring speed, stirring time, temperature of external phase, on evaluatory parameters such as size, entrapment efficiency, and in vitro release of naproxen were studied. The microspheres were characterized for particle size, scanning electron microscopy (SEM), FT-IR spectroscopy, drug entrapment efficiency, in vitro release studies, for in vitro release kinetics. The shape of microspheres was found to be spherical by SEM. The drug entrapment efficiency of various batches of microspheres was found to be ranging from 60 to 90 %w/w. In vitro drug release studies were carried out up to 24 h in pH 7.4 phosphate buffer showing 50-65% drug release. In vitro drug release from all the batches showed better fitting with the Korsmeyer-Peppas model, indicating the possible mechanism of drug release to be by diffusion and erosion of the lipid matrix.

  18. Precision Departure Release Capability (PDRC): NASA to FAA Research Transition

    Science.gov (United States)

    Engelland, Shawn; Davis, Thomas J.

    2013-01-01

    After takeoff, aircraft must merge into en route (Center) airspace traffic flows which may be subject to constraints that create localized demand-capacity imbalances. When demand exceeds capacity, Traffic Management Coordinators (TMCs) and Frontline Managers (FLMs) often use tactical departure scheduling to manage the flow of departures into the constrained Center traffic flow. Tactical departure scheduling usually involves use of a Call for Release (CFR) procedure wherein the Tower must call the Center to coordinate a release time prior to allowing the flight to depart. In present-day operations release times are computed by the Center Traffic Management Advisor (TMA) decision support tool based upon manual estimates of aircraft ready time verbally communicated from the Tower to the Center. The TMA-computed release time is verbally communicated from the Center back to the Tower where it is relayed to the Local controller as a release window that is typically three minutes wide. The Local controller will manage the departure to meet the coordinated release time window. Manual ready time prediction and verbal release time coordination are labor intensive and prone to inaccuracy. Also, use of release time windows adds uncertainty to the tactical departure process. Analysis of more than one million flights from January 2011 indicates that a significant number of tactically scheduled aircraft missed their en route slot due to ready time prediction uncertainty. Uncertainty in ready time estimates may result in missed opportunities to merge into constrained en route flows and lead to lost throughput. Next Generation Air Transportation System plans call for development of Tower automation systems capable of computing surface trajectory-based ready time estimates. NASA has developed the Precision Departure Release Capability (PDRC) concept that improves tactical departure scheduling by automatically communicating surface trajectory-based ready time predictions and

  19. Sustained release nimesulide microparticles: evaluation of release modifying property of ethy

    International Nuclear Information System (INIS)

    Khan, S.A.; Ahmed, M.; Nisar-ur-Rehman; Madni, A.U.; Aamir, M.N.; Murtaza, G.

    2011-01-01

    Microencapsulated controlled-release preparations of nimesulide were formulated. Microparticles were prepared by modified phase separation (non-solvent addition) technique using different ratios of ethylcellulose. The microparticles (M/sub 1/, M/sub 2/, and M/sub 3/) were yellow, free flowing and spherical in shape with the particle size varying from 93.62 +- 14.15 to 104.19 +- 18.15 mu m. The t/sub 60%/of nimesulide release from microparticles was found to be 3 +- 0.6, 5 +- 0.6 and 8 +- 0.8 h for formulations M/sub 1/, M/sub 2/, and M/sub 3/, respectively. FT-IR, XRD, and thermal analysis were done which showed that there is no interaction between the polymer and drug. The mechanism of drug release from nimesulide microparticles was studied by using Higuchi and Korsmeyer-Peppas models. The value of coefficient of determination (R/sup 2/) for M/sub 1/, M/sub 2/, and M/sub 3/ indicates anomalous and case-II transport release mechanism. The dissolution data of designed system verified its ability to maintain plasma concentration without the need of frequent dosing. The Nimesulide microparticles prolonged drug release for 12 hours or longer. Based on the results of release studies, M/sub 3/ was opted as a suitable microparticulate formulation allowing the controlled release of nimesulide over a prolonged period of time. Moreover, its encapsulation efficiency was also comparable to the other two formulations (M/sub 1/ and M/sub 2/). In conclusion, the influence of polymer concentration should be considered during formulation development. (author)

  20. Time- and dose-related effects of a gonadotropin-releasing hormone agonist and dopamine antagonist on reproduction in the Northern leopard frog (Lithobates pipiens).

    Science.gov (United States)

    Vu, Maria; Weiler, Bradley; Trudeau, Vance L

    2017-12-01

    Gonadotropin-releasing hormone (GnRH) stimulates luteinizing hormone release to control ovulation and spermiation in vertebrates. Dopamine (DA) has a clear inhibitory role in the control of reproduction in numerous teleosts, and emerging evidence suggests that similar mechanisms may exist in amphibians. The interactions between GnRH and DA on spawning success and pituitary gene expression in the Northern leopard frog (Lithobates pipiens) were therefore investigated. Frogs were injected during the natural breeding season with a GnRH agonist [GnRH-A; (Des-Gly 10 , D-Ala 6 , Pro-NHEt 9 )-LHRH; 0.1μg/g and 0.4μg/g] alone and in combination with the dopamine receptor D2 antagonist metoclopramide (MET; 5μg/g and 10μg/g). Injected animals were allowed to breed in outdoor mesocosms. Time to amplexus and oviposition were assessed, and egg mass release, incidences of amplexus, egg mass weight, total egg numbers and fertilization rates were measured. To examine gene expression, female pituitaries were sampled at 12, 24 and 36h following injection of GnRH-A (0.4μg/g) alone and in combination with MET (10μg/g). The mRNA levels of the genes lhb, fshb, gpha, drd2 and gnrhr1 were measured using quantitative real-time PCR. Data were analyzed by a two-way ANOVA. Both GnRH-A doses increased amplexus, oviposition and fertilization alone. Co-injection of MET with GnRH-A did not further enhance spawning success. Injection of GnRH-A alone time-dependently increased expression of lhb, fshb, gpha and gnrhr1. The major effect of MET alone was to decrease expression of drd2. Importantly, the stimulatory effects of GnRH-A on lhb, gpha and gnrhr1 were potentiated by the co-injection of MET at 36h. At this time, expression of fshb was increased only in animals injected with both GnRH-A and MET. Spawning success was primarily driven by the actions of GnRH-A. The hypothesized inhibitory action of DA was supported by pituitary gene expression analysis. The results from this study provide a

  1. Cumulative release to the accessible environment

    International Nuclear Information System (INIS)

    Kanehiro, B.

    1985-01-01

    The Containment and Isolation Working Group considered issues related to the postclosure behavior of repositories in crystalline rock. This working group was further divided into subgroups to consider the progress since the 1978 GAIN Symposium and identify research needs in the individual areas of regional ground-water flow, ground-water travel time, fractional release, and cumulative release. The analysis and findings of the Fractional Release Subgroup are presented

  2. Recidivism Among Licensed-Released Prisoners Who Participated in the EM Program in Israel.

    Science.gov (United States)

    Shoham, Efrat; Yehosha-Stern, Shirley; Efodi, Rotem

    2015-08-01

    Toward the end of 2006, a pilot program was launched in Israel wherein licensed-released prisoners were put under electronic monitoring (EM). In addition to EM, the pilot program, operated by the Prisoners' Rehabilitation Authority, provides programs of occupational supervision and personal therapy and is designed to allow for early release of those prisoners who, without increased supervision, would have been found unsuitable for early release. The aim of this study was to ascertain whether participation in the EM program among licensed-released prisoners in Israel might bring about lessened recidivism. For that matter, rates of arrests and incarceration were examined during a follow-up period of up to 4 years, among the entirety of licensed-released prisoners participating in the EM program between the years 2007 and 2009 (n = 155). To compare recidivism rates, a control group was assembled from among the entirety of released prisoners who were found unsuitable for early release in judicial conditions, and had therefore served the full term of their incarceration, to be released between the years 2005 and 2006 (a period of time during which an EM program was not yet operated among licensed-released prisoners in Israel). Study findings clearly show that while among the control group, 42% of released prisoners were re-incarcerated, at the end of a 4-year follow-up period, only 15% among the study group had returned to prison. These findings can be explained by combining the Social Control theory and the Self-Control theory which consider the period of time under EM program and the occupational and familial integration tools for reducing criminal connections and enhancing pro-social behavior. © The Author(s) 2014.

  3. Meteorological data assimilation for real-time emergency response

    International Nuclear Information System (INIS)

    Sugiyama, G.; Chan, S.T.

    1996-11-01

    The US Department of Energy's Atmospheric Release Advisory Capability (ARAC) provides real-time dose assessments of airborne pollutant releases. Diverse data assimilation techniques are required to meet the needs of a new generation of ARAC models and to take advantage of the rapidly expanding availability of meteorological data. We are developing a hierarchy of algorithms to provide gridded meteorological fields which can be used to drive dispersion codes or to provide initial fields for mesoscale models. Data to be processed include winds, temperature, moisture, and turbulence

  4. Real-time investigation of antibiotics-induced oxidative stress and superoxide release in bacteria using an electrochemical biosensor.

    Science.gov (United States)

    Liu, Xiaobo; Marrakchi, Mouna; Jahne, Michael; Rogers, Shane; Andreescu, Silvana

    2016-02-01

    The involvement of oxidative stress in the mechanism of antibiotics-meditated cell death is unclear and subject to debate. The kinetic profile and a quantitative relationship between the release of reactive oxygen species (ROS), bacteria and antibiotic type remain elusive. Here we report direct measurements and analytical quantification of the release of superoxide radicals (O2(·-)), a major contributor to ROS, in antibiotics-treated bacterial cultures using a cytochrome c electrochemical biosensor. The specificity of electrochemical measurements was established by the addition of superoxide dismutase (SOD) which decreased the O2(·-) signal. Measurements using a general ROS-specific fluorescence dye and colony forming units (CFU) assays were performed side-by-side to determine the total ROS and establish the relationship between ROS and the degree of lethality. Exposure of Escherichia coli and Listeria monocytogenes cultures to antibiotics increased the release of O2(·-) radicals in a dose-dependent manner, suggesting that the transmembrane generation of ROS may occur as part of the antibiotic action. The study provides a quantitative methodology and fundamental knowledge to further explore the role of oxidative stress in antibiotics-meditated bacterial death and to assess physiological changes associated with the complex metabolic events related to oxidative stress and bacterial resistance. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Ultrafast release and capture of carriers in InGaAs/GaAs quantum dots observed by time-resolved terahertz spectroscopy

    DEFF Research Database (Denmark)

    Porte, Henrik; Jepsen, Peter Uhd; Daghestani, N.

    2009-01-01

    We observe ultrafast release and capture of charge carriers in InGaAs/GaAs quantum dots in a room-temperature optical pump-terahertz probe experiment sensitive to the population dynamics of conducting states. In case of resonant excitation of the quantum dot ground state, the maximum conductivity...... is achieved at approximately 35 ps after photoexcitation, which is assigned to release of carriers from the quantum dots. When exciting carriers into the conduction band of the barriers, depletion of the conductivity via carrier capture into the quantum dots with a few picosecond pump fluence-dependent time...

  6. Time course and predictors of median nerve conduction after carpal tunnel release.

    Science.gov (United States)

    Rotman, Mitchell B; Enkvetchakul, Bobby V; Megerian, J Thomas; Gozani, Shai N

    2004-05-01

    To identify predictors of outcome and of electrophysiologic recovery in patients with carpal tunnel syndrome (CTS) treated by endoscopic carpal tunnel release using a nerve conduction testing system (NC-Stat; NEUROMetrix, Inc, Waltham, MA). Validity of the automated nerve conduction testing system was shown by comparing presurgical distal motor latencies (DMLs) against a reference obtained by referral to an electromyography laboratory. The DML was evaluated in 48 patients with CTS. Measurements were obtained within 1 hour of surgery and at 2 weeks, 6 weeks, 3 months, and 6 months after carpal tunnel release. Presurgical and postsurgical DMLs were then compared and correlated with variables and possible predictors of outcome including age, body mass index, gender, and presurgical DMLs. The automated nerve conduction testing system DMLs matched those of reference electromyography/nerve conduction study values with high correlation. Sensitivity of the automated nerve conduction testing system when compared with a standardized CTS case definition was 89%, with a specificity of 95%. A significant correlation was found between the DML before release and the DML 1 hour after release. Moreover, maximal postsurgical DML improvement was highly dependent on the presurgical DML, with no improvement shown for the 6-ms group. Among the clinical variables of age, gender, and body mass index only age was mildly predictive of postrelease DML changes at 6 months. No other correlations between clinical variables and postsurgical DMLs were significant. In addition the predictive value of age was lost when combined with the presurgical DML in a multivariate analysis. Postsurgical changes in the median nerve DML were highly dependent on the prerelease latency. The sensitivity and specificity of a nerve conduction monitoring system in detecting and aiding in the diagnosis of CTS is useful in the long-term management of patients with CTS and can aid in determining the level of improvement

  7. Releases of radioactivity at the Savannah River Plant, 1954--1985

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Lawrimore, I.B.

    1988-07-01

    Radioactive releases from Savannah River Plant (SRP) facilities to air, water and earthen seepage basins have been monitored and tabulated throughout the history of the site. The purpose of this report is to provide a source of data on routine releases of radioactivity to air, water and seepage basins that can be used for analyses of trends, environmental impact, etc. As used in this report, routine radioactive releases means radioactive materials that are released through established effluents from process facilities. This report provides a summary of radioactive releases that inflects the release values contained m records and documents from startup through 1985

  8. Inverse modelling for real-time estimation of radiological consequences in the early stage of an accidental radioactivity release.

    Science.gov (United States)

    Pecha, Petr; Šmídl, Václav

    2016-11-01

    A stepwise sequential assimilation algorithm is proposed based on an optimisation approach for recursive parameter estimation and tracking of radioactive plume propagation in the early stage of a radiation accident. Predictions of the radiological situation in each time step of the plume propagation are driven by an existing short-term meteorological forecast and the assimilation procedure manipulates the model parameters to match the observations incoming concurrently from the terrain. Mathematically, the task is a typical ill-posed inverse problem of estimating the parameters of the release. The proposed method is designated as a stepwise re-estimation of the source term release dynamics and an improvement of several input model parameters. It results in a more precise determination of the adversely affected areas in the terrain. The nonlinear least-squares regression methodology is applied for estimation of the unknowns. The fast and adequately accurate segmented Gaussian plume model (SGPM) is used in the first stage of direct (forward) modelling. The subsequent inverse procedure infers (re-estimates) the values of important model parameters from the actual observations. Accuracy and sensitivity of the proposed method for real-time forecasting of the accident propagation is studied. First, a twin experiment generating noiseless simulated "artificial" observations is studied to verify the minimisation algorithm. Second, the impact of the measurement noise on the re-estimated source release rate is examined. In addition, the presented method can be used as a proposal for more advanced statistical techniques using, e.g., importance sampling. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Building Adjustable Pre-storm Reservoir Flood-control Release Rules

    Science.gov (United States)

    Yang, Shun-Nien; Chang, Li-Chiu; Chang, Fi-John; Hsieh, Cheng-Daw

    2017-04-01

    Typhoons hit Taiwan several times every year, which could cause serious flood disasters. Because mountainous terrains and steep landforms can rapidly accelerate the speed of flood flow during typhoon events, rivers cannot be a stable source of water supply. Reservoirs become the most effective floodwater storage facilities for alleviating flood damages in Taiwan. The pre-storm flood-control release can significantly increase reservoir storage capacity available to store floodwaters for reducing downstream flood damage, while the uncertainties of total forecasted rainfalls are very high in different stages of an oncoming typhoon, which may cause the risk of water shortage in the future. This study proposes adjustable pre-storm reservoir flood-control release rules in three designed operating stages with various hydrological conditions in the Feitsui Reservoir, a pivot reservoir for water supply to Taipei metropolitan in Taiwan, not only to reduce the risk of reservoir flood control and downstream flooding but also to consider water supply. The three operating stages before an oncoming typhoon are defined upon the timings when: (1) typhoon news is issued (3-7days before typhoon hit); (2) the sea warning is issued (2-4 days before typhoon hit); and (3) the land warning is issued (1-2 days before typhoon hit). We simulate 95 historical typhoon events with 3000 initial water levels and build some pre-storm flood-control release rules to adjust the amount of pre-release based on the total forecasted rainfalls at different operating stages. A great number of simulations (68.4 millions) are conducted to extract their major consequences and then build the adjustable pre-storm reservoir flood-control release rules. Accordingly, given a total forecasted rainfall and a water level, reservoir decision makers can easily identify the corresponding rule to tell the amount of pre-release in any stage. The results show that the proposed adjustable pre-release rules can effectively

  10. Creep rupture behavior of polypropylene suture material and its applications as a time-release mechanism

    International Nuclear Information System (INIS)

    Kusy, R.P.; Whitley, J.Q.

    1983-01-01

    The controlled failure of polypropylene (PP) sutures is studied via creep rupture tests. From plots of log time (tB) vs. stress (sigma), linear relationships are generated over the failure times of 1-1000 h. Results show that as a function of stress, the time dependence varies with irradiation dose (15, 20, 25, and 50 Mrad), irradiation atmosphere (air and vacuum), suture diameter (7-0, 6-0, 5-0, and 4-0), and test temperature (26 and 37 degrees C). For a given stress, the time to failure is least for the greatest dose in the presence of air and at the highest temperature. When suture loops are wrapped around a small wire sheave, however, failure occurs in the largest suture as much as two decades sooner than the smallest suture studied. Within the limitations stated herein, they are independent of test method, loop diameter, aging, and humidity. Consequently, after irradiation in vacuum and postirradiation heat treatment, the processed material may be stored at room temperature for at least 1 month. Such materials are advocated when the time release of a dental or medical device is required, for example, in the self-activating cleft palate appliance

  11. Calcitonin gene-related peptide and somatostatin releases correlated with the area under the lafutidine concentration-time curve in human plasma.

    Science.gov (United States)

    Ikawa, K; Shimatani, T; Azuma, Y; Inoue, M; Morikawa, N

    2006-08-01

    To examine the effects of the histamine H(2)-receptor antagonist, lafutidine, at clinical dosage (10 mg tablet after a standardized meal) on plasma levels of the gastrointestinal peptides, calcitonin gene-related peptide (CGRP), somatostatin and gastrin. Six healthy male volunteers ate a standardized meal, and received either lafutidine orally at a dose of 10 mg or water only (control). Blood samples were taken before and up to 4 h after the drug administration. Plasma lafutidine concentrations were determined by high pressure liquid chromatography. Pharmacokinetic analysis of lafutidine was performed using one-compartmental model. The levels of immunoreactive substances of plasma CGRP, somatostatin and gastrin were measured by enzyme immunoassay, and the amount of peptide release was calculated by the trapezoidal method. Lafutidine significantly increased plasma CGRP levels at 1, 1.5, 2.5 and 4 h and the total amount of CGRP release (192 +/- 14.0 pg.h/mL) compared with the control group (128 +/- 21.5 pg.h/mL). Lafutidine significantly increased the plasma somatostatin levels at 1 and 1.5 h, and the total amount of somatostatin released (107 +/- 18.2 pg.h/mL) compared with the control (78.4 +/- 7.70 pg.h/mL). The area under the drug concentration-time curve (AUC) from 0 to 4 h after administration correlated well with the Delta-CGRP and Delta-somatostatin release but not with total amount of gastrin released. However, plasma gastrin levels were significantly elevated at 1.5 h after drug administration. Lafutidine at clinical dosage increases plasma CGRP and the somatostatin. The amounts released correlated with the AUC of lafutidine in humans. These results suggest that the increased release of CGRP and somatostatin may contribute to its gastroprotective and anti-acid secretory effect.

  12. Colloid Release from Soil Aggregates

    DEFF Research Database (Denmark)

    Vendelboe, Anders Lindblad; Møldrup, Per; Schjønning, Per

    2012-01-01

    The content of water-dispersible colloids (WDC) has a major impact on soil functions and structural stability. In addition, the presence of mobile colloids may increase the risk of colloid-facilitated transport of strongly sorbing environmental contaminants. The WDC content was measured in 39 soils......, using laser diffraction, by agitating the samples using a wet-dispersion unit. This approach eliminated the need for long sedimentation times required by the more classical end-over-end shaking approach and provided information about the time-dependent release of WDC. The total clay content of the soils...... ranged from 0.1 to 0.44 kg kg−1. The WDC content was measured on air-dry and moist 1- to 2-mm aggregates. The WDC content at a reference time was highly correlated to the total clay content (r > 0.91, P soils. Only for two sites was the WDC content correlated to the content of clay...

  13. Fiber-optic triggered release of liposome in vivo: implication of personalized chemotherapy.

    Science.gov (United States)

    Huang, Huei-Ling; Lu, Pei-Hsuan; Yang, Hung-Chih; Lee, Gi-Da; Li, Han-Ru; Liao, Kuo-Chih

    2015-01-01

    The aim of this research is to provide proof of principle by applying the fiber-optic triggered release of photo-thermally responsive liposomes embedded with gold nanoparticles (AuNPs) using a 200 μm fiber with 65 mW and 532 nm excitation for topical release in vivo. The tunable delivery function can be paired with an apoptosis biosensor based on the same fiber-optic configuration for providing real-time evaluation of chemotherapy efficacy in vivo to perform as a personalized chemotherapy system. The pattern of topical release triggered by laser excitation conveyed through optical fibers was monitored by the increase in fluorescence resulting from the dilution of self-quenching (75 mM) fluorescein encapsulated in liposomes. In in vitro studies (in 37°C phosphate buffer saline), the AuNP-embedded liposomes showed a more efficient triggered release (74.53%±1.63% in 40 minutes) than traditional temperature-responsive liposomes without AuNPs (14.53%±3.17%) or AuNP-liposomes without excitation (21.92%±2.08%) by spectroscopic measurements. Using the mouse xenograft studies, we first demonstrated that the encapsulation of fluorescein in liposomes resulted in a more substantial content retention (81%) in the tumor than for free fluorophores (14%) at 120 minutes after administration from in vivo fluorescence imaging. Furthermore, the preliminary results also suggested the tunable release capability of the system by demonstrating consecutive triggered releases with fiber-optic guided laser excitation.

  14. Simulation model for transcervical laryngeal injection providing real-time feedback.

    Science.gov (United States)

    Ainsworth, Tiffiny A; Kobler, James B; Loan, Gregory J; Burns, James A

    2014-12-01

    This study aimed to develop and evaluate a model for teaching transcervical laryngeal injections. A 3-dimensional printer was used to create a laryngotracheal framework based on de-identified computed tomography images of a human larynx. The arytenoid cartilages and intrinsic laryngeal musculature were created in silicone from clay casts and thermoplastic molds. The thyroarytenoid (TA) muscle was created with electrically conductive silicone using metallic filaments embedded in silicone. Wires connected TA muscles to an electrical circuit incorporating a cell phone and speaker. A needle electrode completed the circuit when inserted in the TA during simulated injection, providing real-time feedback of successful needle placement by producing an audible sound. Face validation by the senior author confirmed appropriate tactile feedback and anatomical realism. Otolaryngologists pilot tested the model and completed presimulation and postsimulation questionnaires. The high-fidelity simulation model provided tactile and audio feedback during needle placement, simulating transcervical vocal fold injections. Otolaryngology residents demonstrated higher comfort levels with transcervical thyroarytenoid injection on postsimulation questionnaires. This is the first study to describe a simulator for developing transcervical vocal fold injection skills. The model provides real-time tactile and auditory feedback that aids in skill acquisition. Otolaryngologists reported increased confidence with transcervical injection after using the simulator. © The Author(s) 2014.

  15. Infrared spectroscopic characterization of monocytic microvesicles (microparticles) released upon lipopolysaccharide stimulation.

    Science.gov (United States)

    Lee, Joonsup; Wen, Beryl; Carter, Elizabeth A; Combes, Valery; Grau, Georges E R; Lay, Peter A

    2017-07-01

    Microvesicles (MVs) are involved in cell-cell interactions, including disease pathogenesis. Nondestructive Fourier-transform infrared (FTIR) spectra from MVs were assessed as a technique to provide new biochemical insights into a LPS-induced monocyte model of septic shock. FTIR spectroscopy provided a quick method to investigate relative differences in biomolecular content of different MV populations that was complementary to traditional semiquantitative omics approaches, with which it is difficult to provide information on relative changes between classes (proteins, lipids, nucleic acids, carbohydrates) or protein conformations. Time-dependent changes were detected in biomolecular contents of MVs and in the monocytes from which they were released. Differences in phosphatidylcholine and phosphatidylserine contents were observed in MVs released under stimulation, and higher relative concentrations of RNA and α-helical structured proteins were present in stimulated MVs compared with MVs from resting cells. FTIR spectra of stimulated monocytes displayed changes that were consistent with those observed in the corresponding MVs they released. LPS-stimulated monocytes had reduced concentrations of nucleic acids, α-helical structured proteins, and phosphatidylcholine compared with resting monocytes but had an increase in total lipids. FTIR spectra of MV biomolecular content will be important in shedding new light on the mechanisms of MVs and the different roles they play in physiology and disease pathogenesis.-Lee, J., Wen, B., Carter, E. A., Combes, V., Grau, G. E. R., Lay, P. A. Infrared spectroscopic characterization of monocytic microvesicles (microparticles) released upon lipopolysaccharide stimulation. © FASEB.

  16. Results of development and field tests of a radar-tracer system providing meteorological support to modeling hazardous technological releases

    International Nuclear Information System (INIS)

    Shershakov, V.M.; Zukov, G.P.; Kosykh, V.S.

    2003-01-01

    radiation monitoring laboratory and the LDU was on the bank of the cooling pond. The main characteristics of a cloud of substances are standard deviations in the spatial concentration distributions in the cloud along mutually perpendicular directions, which are representative spatial scales of the cloud in these directions. The squares of these values are relative variances of the cloud. These characteristics were the first to determine and are among the most important input parameters in different models assessing transport and dispersion of hazardous substances. Dispersion of a cloud of substances is influenced by turbulence and vertical shifts of the mean wind speed, with the patterns of dispersion being different depending an diffusion time (or distance to a source). The results of the conducted experiments have revealed an important advantage of the used radar complex in terms of support to predictions of possible contamination in case of release of hazardous materials. As the chaff cloud moves with the wind and is dispersed, it echoes the meteorological situation at a given time moment (vertical wind distribution and air temperature, turbulence level, boundary layer thickness, type of underlying surface) and any changes occurring in the conditions on its way. Based on obtained radar data, the radar complex is capable of assessing the dispersion parameters which can then be used in the mathematical transport and dispersion models. What's more, determination of these parameters does not require any meteorological measurements. In addition, using data about movement of the cloud centroid, the wind speed and direction is estimated at the release height by the radar complex itself. The conducted experiments have shown that the developed technology makes possible measuring key parameters of a cloud of substances at the height of dispersion and taking into account local features of the distribution of meteorological quantities occurring in the vicinity of a source. This

  17. The ALICE Software Release Validation cluster

    International Nuclear Information System (INIS)

    Berzano, D; Krzewicki, M

    2015-01-01

    One of the most important steps of software lifecycle is Quality Assurance: this process comprehends both automatic tests and manual reviews, and all of them must pass successfully before the software is approved for production. Some tests, such as source code static analysis, are executed on a single dedicated service: in High Energy Physics, a full simulation and reconstruction chain on a distributed computing environment, backed with a sample “golden” dataset, is also necessary for the quality sign off. The ALICE experiment uses dedicated and virtualized computing infrastructures for the Release Validation in order not to taint the production environment (i.e. CVMFS and the Grid) with non-validated software and validation jobs: the ALICE Release Validation cluster is a disposable virtual cluster appliance based on CernVM and the Virtual Analysis Facility, capable of deploying on demand, and with a single command, a dedicated virtual HTCondor cluster with an automatically scalable number of virtual workers on any cloud supporting the standard EC2 interface. Input and output data are externally stored on EOS, and a dedicated CVMFS service is used to provide the software to be validated. We will show how the Release Validation Cluster deployment and disposal are completely transparent for the Release Manager, who simply triggers the validation from the ALICE build system's web interface. CernVM 3, based entirely on CVMFS, permits to boot any snapshot of the operating system in time: we will show how this allows us to certify each ALICE software release for an exact CernVM snapshot, addressing the problem of Long Term Data Preservation by ensuring a consistent environment for software execution and data reprocessing in the future. (paper)

  18. Release plan for Big Pete

    International Nuclear Information System (INIS)

    Edwards, T.A.

    1996-11-01

    This release plan is to provide instructions for the Radiological Control Technician (RCT) to conduct surveys for the unconditional release of ''Big Pete,'' which was used in the removal of ''Spacers'' from the N-Reactor. Prior to performing surveys on the rear end portion of ''Big Pete,'' it shall be cleaned (i.e., free of oil, grease, caked soil, heavy dust). If no contamination is found, the vehicle may be released with the permission of the area RCT Supervisor. If contamination is found by any of the surveys, contact the cognizant Radiological Engineer for decontamination instructions

  19. The hazard to man of accidental releases of tritium

    International Nuclear Information System (INIS)

    Brearley, I.R.

    1985-03-01

    Some aspects of the atmospheric dispersion of tritium are discussed, followed by consideration of the dosimetric pathways. In order to assess the significance of a tritium release the doses from various pathways are estimated and compared with the doses estimated from a similar release of iodine-131. The major hazard from tritium is the ingestion of contaminated food products. For similar releases of tritium and I 131 the ingestion hazard can be comparable if the release occurs near and before the end of the harvest season. However, in the tritium release case the agricultural season influences the consequences markedly and, at other times during the year, the ingestion hazard from tritium may be approximately 20 times less. The dose from inhalation of tritium is sensitive to its chemical form and for similar releases of tritiated water and tritium gas then the dose from tritiated water is approximately 10 4 greater than the dose from tritium gas. For similar releases of tritiated water and iodine-131 then a comparison of the inhalation shows that the dose from the iodine is approximately 300 times greater. (author)

  20. Effect of firing conditions & release height on terminal performance of submunitions and conditions for optimum height of release

    Directory of Open Access Journals (Sweden)

    L.K. Gite

    2017-06-01

    Full Text Available Submunitions should exhibit optimum terminal performance at target end when released from certain pre-determined height. Selection of an optimum height of release of the submunitions depends on the terminal parameters like forward throw, remaining velocity, impact angle and flight time. In this paper, the effects of initial firing conditions and height of release on terminal performance of submunitions discussed in detail. For different height of release, the relation between range and forward throw is also established & validated for a number of firing altitude and rocket configurations.

  1. Effect of ozonolysis pretreatment parameters on the sugar release, ozone consumption and ethanol production from sugarcane bagasse.

    Science.gov (United States)

    Travaini, Rodolfo; Barrado, Enrique; Bolado-Rodríguez, Silvia

    2016-08-01

    A L9(3)(4) orthogonal array (OA) experimental design was applied to study the four parameters considered most important in the ozonolysis pretreatment (moisture content, ozone concentration, ozone/oxygen flow and particle size) on ethanol production from sugarcane bagasse (SCB). Statistical analysis highlighted ozone concentration as the highest influence parameter on reaction time and sugars release after enzymatic hydrolysis. The increase on reaction time when decreasing the ozone/oxygen flow resulted in small differences of ozone consumptions. Design optimization for sugars release provided a parameters combination close to the best experimental run, where 77.55% and 56.95% of glucose and xylose yields were obtained, respectively. When optimizing the grams of sugar released by gram of ozone, the highest influence parameter was moisture content, with a maximum yield of 2.98gSUGARS/gO3. In experiments on hydrolysates fermentation, Saccharomyces cerevisiae provided ethanol yields around 80%, while Pichia stipitis was completely inhibited. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Atmospheric dispersion models of radioactivity releases

    International Nuclear Information System (INIS)

    Oza, R.B.

    2016-01-01

    In view of the rapid industrialization in recent time, atmospheric dispersion models have become indispensible 'tools' to ensure that the effects of releases are well within the acceptable limits set by the regulatory authority. In the case of radioactive releases from the nuclear facility, though negligible in quantity and many a times not even measurable, it is required to demonstrate the compliance of these releases to the regulatory limits set by the regulatory authority by carrying out radiological impact assessment. During routine operations of nuclear facility, the releases are so low that environmental impact is usually assessed with the help of atmospheric dispersion models as it is difficult to distinguish negligible contribution of nuclear facility to relatively high natural background radiation. The accidental releases from nuclear facility, though with negligible probability of occurrence, cannot be ruled out. In such cases, the atmospheric dispersion models are of great help to emergency planners for deciding the intervention actions to minimize the consequences in public domain and also to workout strategies for the management of situation. In case of accidental conditions, the atmospheric dispersion models are also utilized for the estimation of probable quantities of radionuclides which might have got released to the atmosphere. Thus, atmospheric dispersion models are an essential tool for nuclear facility during routine operation as well as in the case of accidental conditions

  3. Controlled release of diuron from an alginate-bentonite formulation: water release kinetics and soil mobility study.

    Science.gov (United States)

    Fernández-Pérez, M; Villafranca-Sánchez, M; González-Pradas, E; Flores-Céspedes, F

    1999-02-01

    The herbicide diuron was incorporated in alginate-based granules to obtain controlled release (CR) properties. The standard formulation (alginate-herbicide-water) was modified by the addition of different sorbents. The effect on diuron release rate caused by incorporation of natural and acid-treated bentonites in alginate formulation was studied by immersion of the granules in water under static conditions. The release of diuron was diffusion-controlled. The time taken for 50% release of active ingredient to be released into water, T(50), was calculated for the comparison of formulations. The addition of bentonite to the alginate-based formulation produced the higher T(50) values, indicating slower release of the diuron. The mobility of technical and formulated diuron was compared by using soil columns. The use of alginate-based CR formulations containing bentonite produced a less vertical distribution of the active ingredient as compared to the technical product and commercial formulation. Sorption capacities of the various soil constituents for diuron were also determined using batch experiments.

  4. A Smart Europium-Ruthenium Complex as Anticancer Prodrug: Controllable Drug Release and Real-Time Monitoring under Different Light Excitations.

    Science.gov (United States)

    Li, Hongguang; Xie, Chen; Lan, Rongfeng; Zha, Shuai; Chan, Chi-Fai; Wong, Wing-Yan; Ho, Ka-Lok; Chan, Brandon Dow; Luo, Yuxia; Zhang, Jing-Xiang; Law, Ga-Lai; Tai, William C S; Bünzli, Jean-Claude G; Wong, Ka-Leung

    2017-11-09

    A unique, dual-function, photoactivatable anticancer prodrug, RuEuL, has been tailored that features a ruthenium(II) complex linked to a cyclen-europium chelate via a π-conjugated bridge. Under irradiation at 488 nm, the dark-inactive prodrug undergoes photodissociation, releasing the DNA-damaging ruthenium species. Under evaluation-window irradiation (λ irr = one-photon 350 nm or two-photon 700 nm), the drug delivery process can be quantitatively monitored in real-time because of the long-lived red europium emission. Linear relationships between released drug concentration and ESI-MS or luminescence responses are established. Finally, the efficiency of the new prodrug is demonstrated both in vitro RuEuL anticancer prodrug over some existing ones and open the way for decisive improvements in multipurpose prodrugs.

  5. Evaluation of Release-05 GRACE time-variable gravity coefficients over the ocean

    Directory of Open Access Journals (Sweden)

    D. P. Chambers

    2012-10-01

    Full Text Available The latest release of GRACE (Gravity Recovery and Climate Experiment gravity field coefficients (Release-05, or RL05 are evaluated for ocean applications. Data have been processed using the current methodology for Release-04 (RL04 coefficients, and have been compared to output from two different ocean models. Results indicate that RL05 data from the three Science Data Centers – the Center for Space Research (CSR, GeoForschungsZentrum (GFZ, and Jet Propulsion Laboratory (JPL – are more consistent among themselves than the previous RL04 data. Moreover, the variance of residuals with the output of an ocean model is 50–60% lower for RL05 data than for RL04 data. A more optimized destriping algorithm is also tested, which improves the results slightly. By comparing the GRACE maps with two different ocean models, we can better estimate the uncertainty in the RL05 maps. We find the standard error to be about 1 cm (equivalent water thickness in the low- and mid-latitudes, and between 1.5 and 2 cm in the polar and subpolar oceans, which is comparable to estimated uncertainty for the output from the ocean models.

  6. In vitro evaluation of extemporaneously compounded slow-release capsules containing morphine sulfate or oxycodone hydrochloride.

    Science.gov (United States)

    Glowiak, Dana L; Green, Julie L; Bowman, Bill J

    2005-01-01

    The in vitro performance of extemporaneously compounded morphine sulfate and oxycodone hydrochloride slow-release capsules was evaluated. Capsules containing varying amoutns of morphine sulfate (15, 60, 200 mg) or oxycodone hydrochloride (10, 80, 200 mg) were prepared and provided by a Phoenix, Arizona, pharmacy. The capsules also contained 40% Methocel E4M Premium to slow the release of their active ingredient and sufficient lactose to fill the capsules. Three batches of each capsule strength were prepared, and replicates from each batch were evlauated using United Stated Pharmacopeia dissolution apparatus II. Samples were taken at regular time intervals over 24 hours. After 1 hour the pH of the dissolution medium was adjusted form 1.2 to 4.0, and after 2 hours the pH was adjusted to 6.8. The amount of drug released at each time point was determined spectrophotometrically. The compounded capsules released 14% to 23%, 67% to 85% and 93% to 98% of their active ingredient after 0.5, 4 and 12 hours, respectively. The relative standard deviations between the replicates from each batch were less than 10% for most time points. The percent of drug released over the first 4 hours was linear (r squared = 0.9409-0.9999) when plotted versus time 1/2, indicating adherence to the simplified Higuchi model. Statistical analysis of the Higuchi dissolution constants indicated a significant difference (P less than 0.05) between batch No.3 and the other two batches of 200-mg oxycodone hydrochloride capsules. There was also a statistical difference between most of the Higuchi dissolution constants for the different-strength slow-release capsules and most slow-release capsules and equivalent strength controlled-release manufactured tablets (P less than 0.05). Using 40% Methocel E4M Premium slowed the release of morphine sulfate and oxycodone hydrochloride from extemporaneously compounded capsules. The in vitro performance of the slow-release capsules showed little intrabatch variation

  7. FIRST TIME ONLINE LEARNERS’ PERCEPTIONS OF SUPPORT SERVICES PROVIDED

    Directory of Open Access Journals (Sweden)

    Stephanie HUNTE

    2012-04-01

    Full Text Available The number of online continuous education and training initiatives continues to increase in Caribbean Small Island Developing States (SIDS and by extension, the number of adult learners who are unfamiliar with the peculiarities of the online teaching and learning environment. The extent to which these learners can derive maximum benefit from these initiatives depends on the rate at which they can adapt to the new circumstances and, as a result, function effectively in this type of teaching and learning environment. To this end, while supporting learners is recognized as a critical success factor little has been explored or documented specific to the Caribbean-SIDS context. The purpose of this study therefore was to describe the support services provided first time online learners in the context of Caribbean-SIDS and examine what if any benefit learners derived from them through their perceptions of these services. The findings reveal that participants’ overall perception of the support services was high. They also reveal that although participants’ awareness of ongoing support services was variable, their rating of the need for and importance of this type of support was also high. The findings suggest that providing support for first time online learners in the context of Caribbean SIDS positively impacts their performance in the online teaching and learning environment.

  8. Providing Survivable Real-Time Communication Service for Distributed Mission Critical Systems

    National Research Council Canada - National Science Library

    Zhao, Wei; Bettati, Riccardo; Vaidya, Nitin

    2005-01-01

    This document is the final report for Providing Survivable Real-Time Communication Service for Distributed Mission Critical Systems, a Texas A AND M project funded through the DARPA Fault Tolerant Networks Program...

  9. Fiber-optic triggered release of liposome in vivo: implication of personalized chemotherapy

    Directory of Open Access Journals (Sweden)

    Huang HL

    2015-08-01

    Full Text Available Huei-Ling Huang,1 Pei-Hsuan Lu,1 Hung-Chih Yang,1 Gi-Da Lee,1,2 Han-Ru Li,1 Kuo-Chih Liao1 1Graduate Institute of Biomedical Engineering, National Chung Hsing University, 2Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan Abstract: The aim of this research is to provide proof of principle by applying the fiber-optic triggered release of photo-thermally responsive liposomes embedded with gold nanoparticles (AuNPs using a 200 µm fiber with 65 mW and 532 nm excitation for topical release in vivo. The tunable delivery function can be paired with an apoptosis biosensor based on the same fiber-optic configuration for providing real-time evaluation of chemotherapy efficacy in vivo to perform as a personalized chemotherapy system. The pattern of topical release triggered by laser excitation conveyed through optical fibers was monitored by the increase in fluorescence resulting from the dilution of self-quenching (75 mM fluorescein encapsulated in liposomes. In in vitro studies (in 37°C phosphate buffer saline, the AuNP-embedded liposomes showed a more efficient triggered release (74.53%±1.63% in 40 minutes than traditional temperature-responsive liposomes without AuNPs (14.53%±3.17% or AuNP-liposomes without excitation (21.92%±2.08% by spectroscopic measurements. Using the mouse xenograft studies, we first demonstrated that the encapsulation of fluorescein in liposomes resulted in a more substantial content retention (81% in the tumor than for free fluorophores (14% at 120 minutes after administration from in vivo fluorescence imaging. Furthermore, the preliminary results also suggested the tunable release capability of the system by demonstrating consecutive triggered releases with fiber-optic guided laser excitation. Keywords: fiber-optic guided excitation, light excitation triggered release, photo-thermal responsive liposome, gold nanoparticles, tunable release in vivo

  10. Controlled release of insect sex pheromones from paraffin wax and emulsions.

    Science.gov (United States)

    Atterholt, C A; Delwiche, M J; Rice, R E; Krochta, J M

    1999-02-22

    Paraffin wax and aqueous paraffin emulsions can be used as controlled release carriers for insect sex pheromones for mating disruption of orchard pests. Paraffin can be applied at ambient temperature as an aqueous emulsion, adheres to tree bark or foliage, releases pheromone for an extended period of time, and will slowly erode from bark and biodegrade in soil. Pheromone emulsions can be applied with simple spray equipment. Pheromone release-rates from paraffin were measured in laboratory flow-cell experiments. Pheromone was trapped from an air stream with an adsorbent, eluted periodically, and quantified by gas chromatography. Pheromone release from paraffin was partition-controlled, providing a constant (zero-order) release rate. A typical paraffin emulsion consisted of 30% paraffin, 4% pheromone, 4% soy oil, 1% vitamin E, 2% emulsifier, and the balance water. Soy oil and vitamin E acted as volatility suppressants. A constant release of oriental fruit moth pheromone from paraffin emulsions was observed in the laboratory for more than 100 days at 27 degreesC, with release-rates ranging from 0.4 to 2 mg/day, depending on the concentration and surface area of the dried emulsion. The use of paraffin emulsions is a viable method for direct application of insect pheromones for mating disruption. Sprayable formulations can be designed to release insect pheromones to the environment at a rate necessary for insect control by mating disruption. At temperatures below 38 degreesC, zero-order release was observed. At 38 degreesC and higher, pheromone oxidation occurred. A partition-controlled release mechanism was supported by a zero-order pheromone release-rate, low air/wax partition coefficients, and pheromone solubility in paraffin.

  11. Modulating drug release from gastric-floating microcapsules through spray-coating layers.

    Directory of Open Access Journals (Sweden)

    Wei Li Lee

    Full Text Available Floating dosage forms with prolonged gastric residence time have garnered much interest in the field of oral delivery. However, studies had shown that slow and incomplete release of hydrophobic drugs during gastric residence period would reduce drug absorption and cause drug wastage. Herein, a spray-coated floating microcapsule system was developed to encapsulate fenofibrate and piroxicam, as model hydrophobic drugs, into the coating layers with the aim of enhancing and tuning drug release rates. Incorporating fenofibrate into rubbery poly(caprolactone (PCL coating layer resulted in a complete and sustained release for up to 8 h, with outermost non-drug-holding PCL coating layer serving as a rate-controlling membrane. To realize a multidrug-loaded system, both hydrophilic metformin HCl and hydrophobic fenofibrate were simultaneously incorporated into these spray-coated microcapsules, with metformin HCl and fenofibrate localized within the hollow cavity of the capsule and coating layer, respectively. Both drugs were observed to be completely released from these coated microcapsules in a sustained manner. Through specific tailoring of coating polymers and their configurations, piroxicam loaded in both the outer polyethylene glycol and inner PCL coating layers was released in a double-profile manner (i.e. an immediate burst release as the loading dose, followed by a sustained release as the maintenance dose. The fabricated microcapsules exhibited excellent buoyancy in simulated gastric fluid, and provided controlled and sustained release, thus revealing its potential as a rate-controlled oral drug delivery system.

  12. 14C release from failed spent fuel containers

    International Nuclear Information System (INIS)

    Pescatore, C.

    1990-01-01

    Partially failed containers may provide a meaningful barrier to the release of gaseous radionuclides. A modeling approach is outlined and sample calculations are provided that show the effects on release due to a limited perforation area, to decreasing temperature, and to the partial occlusion of the perforated area by corrosion products. 8 refs., 2 tabs

  13. PCDD/PCDF release inventories

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, H. [UNEP Chemicals, Chatelaine (Switzerland)

    2004-09-15

    The Stockholm Convention on Persistent Organic Pollutants (POPs) entered into force on 17 May 2004 with 50 Parties. In May 2004, 59 countries had ratified or acceded the Convention. The objective of the Convention is ''to protect human health and the environment from persistent organic pollutants''. For intentionally produced POPs, e.g., pesticides and industrial chemicals such as hexachlorobenzene and polychlorinated biphenyls, this will be achieved by stop of production and use. For unintentionally generated POPs, such as polychlorinated dibenzo-pdioxins (PCDD) and polychlorinated dibenzofurans (PCDF), measures have to be taken to ''reduce the total releases derived from anthropogenic sources''; the final goal is ultimate elimination, where feasible. Under the Convention, Parties have to establish and maintain release inventories to prove the continuous release reduction. Since many countries do not have the technical and financial capacity to measure all releases from all potential PCDD/PCDF sources, UNEP Chemicals has developed the ''Standardized Toolkit for the Identification of Quantification of Dioxin and Furan Releases'' (''Toolkit'' for short), a methodology to estimate annual releases from a number of sources. With this methodology, annual releases can be estimated by multiplying process-specific default emission factors provided in the Toolkit with national activity data. At the seventh session of the Intergovernmental Negotiating Committee, the Toolkit was recommended to be used by countries when reporting national release data to the Conference of the Parties. The Toolkit is especially used by developing countries and countries with economies in transition where no measured data are available. Results from Uruguay, Thailand, Jordan, Philippines, and Brunei Darussalam have been published.

  14. Calculations in support of a potential definition of large release

    International Nuclear Information System (INIS)

    Hanson, A.L.; Davis, R.E.; Mubayi, V.

    1994-05-01

    The Nuclear Regulatory Commission has stated a hierarchy of safety goals with the qualitative safety goals as Level I of the hierarchy, backed up by the quantitative health objectives as Level II and the large release guideline as Level III. The large release guideline has been stated in qualitative terms as a magnitude of release of the core inventory whose frequency should not exceed 10 -6 per reactor year. However, the Commission did not provide a quantitative specification of a large release. This report describes various specifications of a large release and focuses, in particular, on an examination of releases which have a potential to lead to one prompt fatality in the mean. The basic information required to set up the calculations was derived from the simplified source terms which were obtained from approximations of the NUREG-1150 source terms. Since the calculation of consequences is affected by a large number of assumptions, a generic site with a (conservatively determined) population density and meteorology was specified. At this site, various emergency responses (including no response) were assumed based on information derived from earlier studies. For each of the emergency response assumptions, a set of calculations were performed with the simplified source terms; these included adjustments to the source terms, such as the timing of the release, the core inventory, and the release fractions of different radionuclides, to arrive at a result of one mean prompt fatality in each case. Each of the source terms, so defined, has the potential to be a candidate for a large release. The calculations show that there are many possible candidate source terms for a large release depending on the characteristics which are felt to be important

  15. Study on large release frequency of nuclear power plants

    International Nuclear Information System (INIS)

    Chen Yan; Song Wei; Li Chaojun; Fu Zhiwei; Wang Zhe; Zuo Jiaxu; Tong Jiejuan

    2014-01-01

    There are several definitions of large release frequency of nuclear power plant. This paper reviews the meanings of large release and requirement of large release frequency provided by IAEA, NRC and WENRA, analyses the relationship between the meanings of large release, compares the calculations of several large release frequencies, It is different frequency that the definition of LRF is not same. Last we discuss the difference between large release frequency and large early release frequency and explore the suitable definitions of LRF for nuclear power plants in China. (authors)

  16. Quick release latch for reactor scram

    International Nuclear Information System (INIS)

    Johnson, M.L.; Shawver, B.M.

    1976-01-01

    A simple, reliable, and fast-acting means for releasing a control element and allowing it to be inserted rapidly into the core region of a nuclear reactor for scram purposes is described. A latch mechanism grips a coupling head on a nuclear control element to connect the control element to the control drive assembly. The latch mechanism is closed by tensioning a cable or rod with an actuator. The control element is released by de-energizing the actuator, providing fail-safe, rapid release of the control element to effect reactor shutdown. A sensing rod provides indication that the control element is properly positioned in the latch. Two embodiments are illustrated, one involving a collet-type latch mechanism, the other a pliers-type latch mechanism with the actuator located inside the reactor vessel

  17. Quick release latch for reactor scram

    International Nuclear Information System (INIS)

    Johnson, M.L.; Shawver, B.M.

    1975-01-01

    A simple, reliable, and fast-acting means for releasing a control element and allowing it to be inserted rapidly into the core region of a nuclear reactor for scram purposes is described. A latch mechanism grips a coupling head on a nuclear control element to connect the control element to the control drive assembly. The latch mechanism is closed by tensioning a cable or rod with an actuator. The control element is released by de-energizing the actuator, providing fail-safe, rapid release of the control element to effect reactor shutdown. A sensing rod provides indication that the control element is properly positioned in the latch. Two embodiments are illustrated, one involving a collet-type latch mechanism, the other a pliers-type latch mechanism with the actuator located inside the reactor vessel

  18. Butyrate-Loaded Chitosan/Hyaluronan Nanoparticles: A Suitable Tool for Sustained Inhibition of ROS Release by Activated Neutrophils

    DEFF Research Database (Denmark)

    Sacco, Pasquale; Decleva, Eva; Tentor, Fabio

    2017-01-01

    that butyrate inhibits neutrophil ROS release in a dose and time-dependent fashion. Given the short half-life of butyrate, chitosan/hyaluronan nanoparticles are next designed and developed as controlled release carriers able to provide cells with a long-lasting supply of this SCFA. Notably, while the inhibition...... of neutrophil ROS production by free butyrate declines over time, that of butyrate-loaded chitosan/hyaluronan nanoparticles (B-NPs) is sustained. Additional valuable features of these nanoparticles are inherent ROS scavenger activity, resistance to cell internalization, and mucoadhesiveness. B-NPs appear...

  19. Continuous operation of RODOS in case of long lasting releases

    International Nuclear Information System (INIS)

    Raskob, W.; Paesler-Sauer, J.; Rafat, M.

    2003-01-01

    Full text: Under the auspices of its RTD (Research and Technological Development) Framework Programmes, the European Commission has supported the development of the RODOS (Real-time On-line DecisiOn Support) system for off-site emergency management after nuclear accidents since the end of 1989. Significant additional funds have been provided by many national RTD programmes, research institutes and industrial collaborators. In particular, the German Ministry of Environment, Nature Conservation and Reactor Safety (BMU) financially contributed to the project with emphasis an early emergency response. The ongoing RTD work under the EC's 5 th Framework Programme lead to significant extensions, modifications and new developments of both the system and the application software integrated in the RODOS system. All new functions and software components, which have been successfully tested, build the content of RODOD version PV5.0, which has been released in April 2003. One of the new key features of the RODOS system is its capability to deal with release scenarios longer than 24 hours in all its modes of application: in automatic use, the release duration is unlimited; for interactive calculations, the release has to be limited to 47 days. The environmental contamination and the corresponding doses are calculated on a daily basis and add up to get the total values. When calculating early emergency actions (such as sheltering, administration of stable iodine tablets, and evacuation), the time sequence of potential doses from previous days are used to determine weather a certain intervention level has been or will be exceeded at any time during the release and, in that way, to define areas where potential actions might have been initiated in the past. In case of long term countermeasures, the user has been given the option to consider a number of countermeasures which could be implemented during the release phase. This has increased the flexibility of the module for those

  20. Babesiosis for Health Care Providers

    Centers for Disease Control (CDC) Podcasts

    2012-04-25

    This podcast will educate health care providers on diagnosing babesiosis and providing patients at risk with tick bite prevention messages.  Created: 4/25/2012 by Center for Global Health, Division of Parasitic Diseases and Malaria.   Date Released: 4/25/2012.

  1. Effects of Time-Release Caffeine Containing Supplement on Metabolic Rate, Glycerol Concentration and Performance

    Directory of Open Access Journals (Sweden)

    Adam M. Gonzalez, Jay R. Hoffman, Adam J. Wells, Gerald T. Mangine, Jeremy R. Townsend, Adam R. Jajtner, Ran Wang, Amelia A. Miramonti, Gabriel J. Pruna, Michael B. LaMonica, Jonathan D. Bohner, Mattan W. Hoffman, Leonardo P. Oliveira, David H. Fukuda, Maren S. Fragala, Jeffrey R. Stout

    2015-06-01

    Full Text Available This study compared caffeine pharmacokinetics, glycerol concentrations, metabolic rate, and performance measures following ingestion of a time-release caffeine containing supplement (TR-CAF versus a regular caffeine capsule (CAF and a placebo (PL. Following a double-blind, placebo-controlled, randomized, cross-over design, ten males (25.9 ± 3.2 y who regularly consume caffeine ingested capsules containing either TR-CAF, CAF, or PL. Blood draws and performance measures occurred at every hour over an 8-hour period. Plasma caffeine concentrations were significantly greater (p < 0.05 in CAF compared to TR-CAF during hours 2-5 and significantly greater (p = 0.042 in TR-CAF compared to CAF at hour 8. There were no significant differences between trials in glycerol concentrations (p = 0.86 or metabolic measures (p = 0.17-0.91. Physical reaction time was significantly improved for CAF at hour 5 (p=0.01 compared to PL. Average upper body reaction time was significantly improved for CAF and TR-CAF during hours 1-4 (p = 0.04 and p = 0.01, respectively and over the 8-hour period (p = 0.04 and p = 0.001, respectively compared to PL. Average upper body reaction time was also significantly improved for TR-CAF compared to PL during hours 5-8 (p = 0.004. TR-CAF and CAF showed distinct pharmacokinetics yielding modest effects on reaction time, yet did not alter glycerol concentration, metabolic measures, or other performance measures.

  2. Release of ultrafine particles from three simulated building processes

    International Nuclear Information System (INIS)

    Kumar, Prashant; Mulheron, Mike; Som, Claudia

    2012-01-01

    Building activities are recognised to produce coarse particulate matter but less is known about the release of airborne ultrafine particles (UFPs; those below 100 nm in diameter). For the first time, this study has investigated the release of particles in the 5–560 nm range from three simulated building activities: the crushing of concrete cubes, the demolition of old concrete slabs, and the recycling of concrete debris. A fast response differential mobility spectrometer (Cambustion DMS50) was used to measure particle number concentrations (PNC) and size distributions (PNDs) at a sampling frequency of 10 Hz in a confined laboratory room providing controlled environment and near–steady background PNCs. The sampling point was intentionally kept close to the test samples so that the release of new UFPs during these simulated processes can be quantified. Tri–modal particle size distributions were recorded for all cases, demonstrating different peak diameters in fresh nuclei ( 4 cm −3 . These background modal peaks shifted towards the larger sizes during the work periods (i.e. actual experiments) and the total PNCs increased between 2 and 17 times over the background PNCs for different activities. After adjusting for background concentrations, the net release of PNCs during cube crushing, slab demolition, and ‘dry’ and ‘wet’ recycling events were measured as ∼0.77, 19.1, 22.7 and 1.76 (×10 4 ) cm −3 , respectively. The PNDs were converted into particle mass concentrations (PMCs). While majority of new PNC release was below 100 nm (i.e. UFPs), the bulk of new PMC emissions were constituted by the particles over 100 nm; ∼95, 79, 73 and 90% of total PNCs, and ∼71, 92, 93 and 91% of total PMCs, for cube crushing, slab demolition, dry recycling and wet recycling, respectively. The results of this study firmly elucidate the release of UFPs and raise a need for further detailed studies and designing health and safety related exposure guidelines for

  3. 14C release from failed spent fuel containers

    International Nuclear Information System (INIS)

    Pescatore, C.

    1989-01-01

    Partially failed containers may provide a meaningful barrier to the release of gaseous 14 CO 2 . A modeling approach is outlined and sample calculations are provided that show the effect on release due to a limited perforation area, to decreasing temperature, and to partial occlusion of the perforated area by corrosion products. 5 refs., 4 tabs

  4. Acceptability of Extended-Release Naltrexone by Heroin-Dependent Patients and Addiction Treatment Providers in the Netherlands

    NARCIS (Netherlands)

    Zaaijer, Eline; Goudriaan, Anna E.; Koeter, Maarten W. J.; Booij, Jan; van den Brink, Wim

    2016-01-01

    Background: Extended-release naltrexone (XRNT) was developed to overcome poor treatment compliance with oral naltrexone in alcohol and opioid-dependent patients. XRNT injections are registered in the United States and Russia, but not in The Netherlands. However, XRNT can be obtained for individual

  5. Overview study of LNG release prevention and control systems

    Energy Technology Data Exchange (ETDEWEB)

    Pelto, P.J.; Baker, E.G.; Holter, G.M.; Powers, T.B.

    1982-03-01

    The liquefied natural gas (LNG) industry employs a variety of release prevention and control techniques to reduce the likelihood and the consequences of accidental LNG releases. A study of the effectiveness of these release prevention and control systems is being performed. Reference descriptions for the basic types of LNG facilities were developed. Then an overview study was performed to identify areas that merit subsequent and more detailed analyses. The specific objectives were to characterize the LNG facilities of interest and their release prevention and control systems, identify possible weak links and research needs, and provide an analytical framework for subsequent detailed analyses. The LNG facilities analyzed include a reference export terminal, marine vessel, import terminal, peakshaving facility, truck tanker, and satellite facility. A reference description for these facilities, a preliminary hazards analysis (PHA), and a list of representative release scenarios are included. The reference facility descriptions outline basic process flows, plant layouts, and safety features. The PHA identifies the important release prevention operations. Representative release scenarios provide a format for discussing potential initiating events, effects of the release prevention and control systems, information needs, and potential design changes. These scenarios range from relatively frequent but low consequence releases to unlikely but large releases and are the principal basis for the next stage of analysis.

  6. Mechanistic modelling of drug release from polymer-coated and swelling and dissolving polymer matrix systems.

    Science.gov (United States)

    Kaunisto, Erik; Marucci, Mariagrazia; Borgquist, Per; Axelsson, Anders

    2011-10-10

    The time required for the design of a new delivery device can be sensibly reduced if the release mechanism is understood and an appropriate mathematical model is used to characterize the system. Once all the model parameters are obtained, in silico experiments can be performed, to provide estimates of the release from devices with different geometries and compositions. In this review coated and matrix systems are considered. For coated formulations, models describing the diffusional drug release, the osmotic pumping drug release, and the lag phase of pellets undergoing cracking in the coating due to the build-up of a hydrostatic pressure are reviewed. For matrix systems, models describing pure polymer dissolution, diffusion in the polymer and drug release from swelling and eroding polymer matrix formulations are reviewed. Importantly, the experiments used to characterize the processes occurring during the release and to validate the models are presented and discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Evaluation of sodium diclofenac release using natural rubber latex as carrier

    International Nuclear Information System (INIS)

    Aielo, Patricia B.; Borges, Felipe A.; Romeira, Karoline M.; Herculano, Rondinelli D.; Miranda, Matheus Carlos Romeiro; Arruda, Larisa B. de; Lisboa Filho, Paulo Noronha; Drago, Bruno de C.

    2014-01-01

    Sodium Diclofenac is a non-steroidal anti-inflammatory drug (NSAID) taken to reduce inflammation and, as an analgesic, reduce pain. Although this drug is widely used in the general population, properties such as the short half-time and some side effects restrict its clinical use. The most common side effects are: gastric irritation, gastritis, peptic ulcer and bleeding. Studies involving biomaterials as carrier for drug release have been proving their efficiency in overcoming those problems and better controlling the release rate and targeting of the drug. Natural rubber latex (NRL) has been proven excellent for its biocompatibility and ability to stimulate angiogenesis, cellular adhesion and the formation of extracellular matrix, promoting the replacement and regeneration of tissue. In this work, a NRL membrane is used to deliver sodium diclofenac. Sodium diclofenac (NaDic) was found to be adsorbed on the NRL membrane, with little or no incorporation into the membrane bulk, according to energy dispersive Scanning Electron Microscopy with X-Ray microanalysis (SEM-EDS) spectroscopy. In addition, FT-IR shows that there is no molecular-level interaction between drug and NRL. Already, the X-Ray Diffraction (XRD) of NaDic-NRL shows a broader one spectrum than the sharper halo (amorphous characteristic XRD spectrum) of pure NRL. More importantly, the release time of diclofenac in a NRL membrane in vitro was increased from the typical 2-3 h for oral tablets to ca. 74 h. The kinetics of the drug release could be fitted with a double exponential function, with two characteristic times of 0.899 and 32.102 h. In this study, we demonstrated that the interesting properties provided by NRL membranes combined with a controlled release of drug is relevant for biomedical applications.(author)

  8. Evaluation of sodium diclofenac release using natural rubber latex as carrier

    Energy Technology Data Exchange (ETDEWEB)

    Aielo, Patricia B.; Borges, Felipe A.; Romeira, Karoline M.; Herculano, Rondinelli D., E-mail: rond@assis.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Assis, SP (Brazil). Fac. de Ciencias e Letras. Dept. de Ciencias Biologicas; Miranda, Matheus Carlos Romeiro [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Araraquara, SP (Brazil). Inst. de Quimica; Arruda, Larisa B. de; Lisboa Filho, Paulo Noronha; Drago, Bruno de C. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Bauru, SP (Brazil). Fac. de Ciencias. Dept. de Fisica

    2014-08-15

    Sodium Diclofenac is a non-steroidal anti-inflammatory drug (NSAID) taken to reduce inflammation and, as an analgesic, reduce pain. Although this drug is widely used in the general population, properties such as the short half-time and some side effects restrict its clinical use. The most common side effects are: gastric irritation, gastritis, peptic ulcer and bleeding. Studies involving biomaterials as carrier for drug release have been proving their efficiency in overcoming those problems and better controlling the release rate and targeting of the drug. Natural rubber latex (NRL) has been proven excellent for its biocompatibility and ability to stimulate angiogenesis, cellular adhesion and the formation of extracellular matrix, promoting the replacement and regeneration of tissue. In this work, a NRL membrane is used to deliver sodium diclofenac. Sodium diclofenac (NaDic) was found to be adsorbed on the NRL membrane, with little or no incorporation into the membrane bulk, according to energy dispersive Scanning Electron Microscopy with X-Ray microanalysis (SEM-EDS) spectroscopy. In addition, FT-IR shows that there is no molecular-level interaction between drug and NRL. Already, the X-Ray Diffraction (XRD) of NaDic-NRL shows a broader one spectrum than the sharper halo (amorphous characteristic XRD spectrum) of pure NRL. More importantly, the release time of diclofenac in a NRL membrane in vitro was increased from the typical 2-3 h for oral tablets to ca. 74 h. The kinetics of the drug release could be fitted with a double exponential function, with two characteristic times of 0.899 and 32.102 h. In this study, we demonstrated that the interesting properties provided by NRL membranes combined with a controlled release of drug is relevant for biomedical applications.(author)

  9. Uniformity of Peptide Release Is Maintained by Methylation of Release Factors

    Directory of Open Access Journals (Sweden)

    William E. Pierson

    2016-09-01

    Full Text Available Termination of protein synthesis on the ribosome is catalyzed by release factors (RFs, which share a conserved glycine-glycine-glutamine (GGQ motif. The glutamine residue is methylated in vivo, but a mechanistic understanding of its contribution to hydrolysis is lacking. Here, we show that the modification, apart from increasing the overall rate of termination on all dipeptides, substantially increases the rate of peptide release on a subset of amino acids. In the presence of unmethylated RFs, we measure rates of hydrolysis that are exceptionally slow on proline and glycine residues and approximately two orders of magnitude faster in the presence of the methylated factors. Structures of 70S ribosomes bound to methylated RF1 and RF2 reveal that the glutamine side-chain methylation packs against 23S rRNA nucleotide 2451, stabilizing the GGQ motif and placing the side-chain amide of the glutamine toward tRNA. These data provide a framework for understanding how release factor modifications impact termination.

  10. DETERMINATION OF METAL IONS RELEASED BY STAINLESS ...

    African Journals Online (AJOL)

    Preferred Customer

    The study indicated that the reused wires released more ions than new ones at all time points. ... recycled brackets released more ions than the new ones, reduction of the pH of artificial saliva resulted in ... Nickel(II) and vanadium(V) reduce.

  11. Effect of methylmercury on histamine release from rat mast cells

    Energy Technology Data Exchange (ETDEWEB)

    Graevskaya, Elizabeth E.; Rubin, Andrew B. [Moscow State University, Biological Faculty, Department of Biophysics, 119899, Vorobjovy Gory, Moscow (Russian Federation); Yasutake, Akira; Aramaki, Ryoji [National Institute for Minamata Disease, 4058-18 Hama, Minamata, Kumamoto 867-0008 (Japan)

    2003-01-01

    Methylmercury chloride (MeHgCl) is well known as a significant environmental hazard, particularly as a modulator of the immune system. As it is acknowledged that the critical effector cells in the host response participating in various biological responses are mast cells, we tried to define the possible contribution of mast cells in the development of methylmercury-evoked effects. We investigated the effects of methylmercury on the rat mast cell degranulation induced by non-immunological stimuli (the selective liberator of histamine, compound 48/80, and calcium ionophore A23187) both in vivo and in vitro. Using the cells prepared from methylmercury-intoxicated rats through a 5-day treatment of MeHgCl (10 mg/kg/day), we observed the suppression of calcium ionophore A23187- and 48/80-induced histamine release, which was enhanced with time after treatment. Similar suppression was observed in the ionophore-stimulated release, when cells were prepared from rat with a single treatment of MeHgCl (20 mg/kg). It should be noted that when cells from the control rat were pre-incubated with methylmercury in vitro at a 10{sup -8} M concentration for 10 min, A23187 and compound 48/80-stimulated histamine release was significantly enhanced. However, when the pre-incubation period was prolonged to 30 min, the release was suppressed. An increase in the methylmercury concentration to 10{sup -6} M also suppressed the histamine release. These results show that methylmercury treatment can modify mast cell function depending on concentration and time, and might provide an insight into the role of mast cells in the development of methylmercury-stimulated effects. (orig.)

  12. Controlled drug release for tissue engineering.

    Science.gov (United States)

    Rambhia, Kunal J; Ma, Peter X

    2015-12-10

    Tissue engineering is often referred to as a three-pronged discipline, with each prong corresponding to 1) a 3D material matrix (scaffold), 2) drugs that act on molecular signaling, and 3) regenerative living cells. Herein we focus on reviewing advances in controlled release of drugs from tissue engineering platforms. This review addresses advances in hydrogels and porous scaffolds that are synthesized from natural materials and synthetic polymers for the purposes of controlled release in tissue engineering. We pay special attention to efforts to reduce the burst release effect and to provide sustained and long-term release. Finally, novel approaches to controlled release are described, including devices that allow for pulsatile and sequential delivery. In addition to recent advances, limitations of current approaches and areas of further research are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Model to estimate radiation dose commitments to the world population from the atmospheric release of radionuclides (LWBR development program)

    International Nuclear Information System (INIS)

    Rider, J.L.; Beal, S.K.

    1978-02-01

    The equations developed for use in the LWBR environmental statement to estimate the dose commitment over a given time interval to a given organ of the population in the entire region affected by the atmospheric releases of a radionuclide are presented and may be used for any assessment of dose commitments in these regions. These equations define the dose commitments to the world resulting from a released radionuclide and each of its daughters and the sum of these dose commitments provides the total dose commitment accrued from the release of a given radionuclide. If more than one radionuclide is released from a facility, then the sum of the dose commitments from each released nuclide and from each daughter of each released nuclide is the total dose commitment to the world from that facility. Furthermore, if more than one facility is considered as part of an industry, then the sum of the dose commitments from the individual facilities represents the total world dose commitment associated with that industry. The actual solutions to these equations are carried out by the AIRWAY computer program. The writing of this computer program entailed defining in detail the specific representations of the various parameters such as scavenging coefficients, resuspension factors, deposition velocities, dose commitment conversion factors, and food uptake factors, in addition to providing specific numerical values for these types of parameters. The program permits the examination of more than one released nuclide at a time and performs the necessary summing to obtain the total dose commitment to the world accrued from the specified releases

  14. Microgels produced using microfluidic on-chip polymer blending for controlled released of VEGF encoding lentivectors.

    Science.gov (United States)

    Madrigal, Justin L; Sharma, Shonit N; Campbell, Kevin T; Stilhano, Roberta S; Gijsbers, Rik; Silva, Eduardo A

    2018-03-15

    Alginate hydrogels are widely used as delivery vehicles due to their ability to encapsulate and release a wide range of cargos in a gentle and biocompatible manner. The release of encapsulated therapeutic cargos can be promoted or stunted by adjusting the hydrogel physiochemical properties. However, the release from such systems is often skewed towards burst-release or lengthy retention. To address this, we hypothesized that the overall magnitude of burst release could be adjusted by combining microgels with distinct properties and release behavior. Microgel suspensions were generated using a process we have termed on-chip polymer blending to yield composite suspensions of a range of microgel formulations. In this manner, we studied how alginate percentage and degradation relate to the release of lentivectors. Whereas changes in alginate percentage had a minimal impact on lentivector release, microgel degradation led to a 3-fold increase, and near complete release, over 10 days. Furthermore, by controlling the amount of degradable alginate present within microgels the relative rate of release can be adjusted. A degradable formulation of microgels was used to deliver vascular endothelial growth factor (VEGF)-encoding lentivectors in the chick chorioallantoic membrane (CAM) assay and yielded a proangiogenic response in comparison to the same lentivectors delivered in suspension. The utility of blended microgel suspensions may provide an especially appealing platform for the delivery of lentivectors or similarly sized therapeutics. Genetic therapeutics hold considerable potential for the treatment of diseases and disorders including ischemic cardiovascular diseases. To realize this potential, genetic vectors must be precisely and efficiently delivered to targeted regions of the body. However, conventional methods of delivery do not provide sufficient spatial and temporal control. Here, we demonstrate how alginate microgels provide a basis for developing systems for

  15. Using Time-Driven Activity-Based Costing as a Key Component of the Value Platform: A Pilot Analysis of Colonoscopy, Aortic Valve Replacement and Carpal Tunnel Release Procedures.

    Science.gov (United States)

    Martin, Jacob A; Mayhew, Christopher R; Morris, Amanda J; Bader, Angela M; Tsai, Mitchell H; Urman, Richard D

    2018-04-01

    Time-driven activity-based costing (TDABC) is a methodology that calculates the costs of healthcare resources consumed as a patient moves along a care process. Limited data exist on the application of TDABC from the perspective of an anesthesia provider. We describe the use of TDABC, a bottom-up costing strategy and financial outcomes for three different medical-surgical procedures. In each case, a multi-disciplinary team created process maps describing the care delivery cycle for a patient encounter using the TDABC methodology. Each step in a process map delineated an activity required for delivery of patient care. The resources (personnel, equipment and supplies) associated with each step were identified. A per minute cost for each resource expended was generated, known as the capacity cost rate, and multiplied by its time requirement. The total cost for an episode of care was obtained by adding the cost of each individual resource consumed as the patient moved along a clinical pathway. We built process maps for colonoscopy in the gastroenterology suite, calculated costs of an aortic valve replacement by comparing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR) techniques, and determined the cost of carpal tunnel release in an operating room versus an ambulatory procedure room. TDABC is central to the value-based healthcare platform. Application of TDABC provides a framework to identify process improvements for health care delivery. The first case demonstrates cost-savings and improved wait times by shifting some of the colonoscopies scheduled with an anesthesiologist from the main hospital to the ambulatory facility. In the second case, we show that the deployment of an aortic valve via the transcatheter route front loads the costs compared to traditional, surgical replacement. The last case demonstrates significant cost savings to the healthcare system associated with re-organization of staff required to execute a

  16. Feeding Releases Endogenous Opioids in Humans.

    Science.gov (United States)

    Tuulari, Jetro J; Tuominen, Lauri; de Boer, Femke E; Hirvonen, Jussi; Helin, Semi; Nuutila, Pirjo; Nummenmaa, Lauri

    2017-08-23

    The endogenous opioid system supports a multitude of functions related to appetitive behavior in humans and animals, and it has been proposed to govern hedonic aspects of feeding thus contributing to the development of obesity. Here we used positron emission tomography to investigate whether feeding results in hedonia-dependent endogenous opioid release in humans. Ten healthy males were recruited for the study. They were scanned with the μ-opioid-specific ligand [ 11 C]carfentanil three times, as follows: after a palatable meal, a nonpalatable meal, and after an overnight fast. Subjective mood, satiety, and circulating hormone levels were measured. Feeding induced significant endogenous opioid release throughout the brain. This response was more pronounced following a nonpalatable meal versus a palatable meal, and independent of the subjective hedonic responses to feeding. We conclude that feeding consistently triggers cerebral opioid release even in the absence of subjective pleasure associated with feeding, suggesting that metabolic and homeostatic rather than exclusively hedonic responses play a role in the feeding-triggered cerebral opioid release. SIGNIFICANCE STATEMENT The endogenous opioid system supports both hedonic and homeostatic functions. It has been proposed that overeating and concomitant opioid release could downregulate opioid receptors and promote the development of obesity. However, it remains unresolved whether feeding leads to endogenous opioid release in humans. We used in vivo positron emission tomography to test whether feeding triggers cerebral opioid release and whether this response is associated with pleasurable sensations. We scanned volunteers using the μ-opioid receptor-specific radioligand [ 11 C]carfentanil three times, as follows: after an overnight fast, after consuming a palatable meal, and after consuming a nonpalatable meal. Feeding led to significant endogenous opioid release, and this occurred also in the absence of feeding

  17. Environmental releases for calendar year 1994

    International Nuclear Information System (INIS)

    Gleckler, B.P.

    1995-07-01

    This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Orders. This report provides supplemental information to the Hanford Site Environmental Report. The Hanford Site Environmental Report provides an update on the environmental status of the entire Hanford Site. The sitewide annual report summarizes the degree of compliance of the Hanford Site with applicable environmental regulations and informs the public about the impact of Hanford operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities managed by the Westinghouse Hanford Company (WHC) and monitored by Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data on air emissions, liquid effluents, and hazardous substances released to the environment during calendar year 1994 from these facilities

  18. An approach for estimating toxic releases of H{sub 2}S-containing natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Jianwen, Zhang, E-mail: zhangjw@mail.buct.edu.cn [Lab of Fluid Flow and Heat Transfer, Beijing University of Chemical Technology, Beijing 100029 (China); Institute of Safety Management, Beijing University of Chemical Technology, Beijing 100029 (China); Da, Lei [Lab of Fluid Flow and Heat Transfer, Beijing University of Chemical Technology, Beijing 100029 (China); College of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Wenxing, Feng [Pipeline Research Center of PetroChina Company Lmited, 51 Golden Road, Langfang 065000 (China)

    2014-01-15

    Highlights: • Behavior of H{sub 2}S-containing natural gas exhibits appearance of neutral gas by CFD. • The poisoning hazards of H{sub 2}S by gas pipeline releases are successfully estimated. • An assessment method for available safe egress time is proposed. -- Abstract: China is well known being rich in sulfurous natural gas with huge deposits widely distributed all over the country. Due to the toxic nature, the release of hydrogen sulfide-containing natural gas from the pipelines intends to impose serious threats to the human, society and environment around the release sources. CFD algorithm is adopted to simulate the dispersion process of gas, and the results prove that Gaussian plume model is suitable for determining the affected region of the well blowout of sulfide hydrogen-containing natural gas. In accordance with the analysis of release scenarios, the present study proposes a new approach for estimating the risk of hydrogen sulfide poisoning hazards, as caused by sulfide-hydrogen-containing natural gas releases. Historical accident-statistical data from the EGIG (European Gas Pipeline Incident Data Group) and the Britain Gas Transco are integrated into the approach. Also, the dose-load effect is introduced to exploit the hazards’ effects by two essential parameters – toxic concentration and exposure time. The approach was applied to three release scenarios occurring on the East-Sichuan Gas Transportation Project, and the individual risk and societal risk are classified and discussed. Results show that societal risk varies significantly with different factors, including population density, distance from pipeline, operating conditions and so on. Concerning the dispersion process of hazardous gas, available safe egress time was studied from the perspective of individual fatality risks. The present approach can provide reliable support for the safety management and maintenance of natural gas pipelines as well as evacuations that may occur after

  19. Stimuli responsive nanomaterials for controlled release applications

    KAUST Repository

    Li, Song

    2012-01-01

    The controlled release of therapeutics has been one of the major challenges for scientists and engineers during the past three decades. Coupled with excellent biocompatibility profiles, various nanomaterials have showed great promise for biomedical applications. Stimuli-responsive nanomaterials guarantee the controlled release of cargo to a given location, at a specific time, and with an accurate amount. In this review, we have combined the major stimuli that are currently used to achieve the ultimate goal of controlled and targeted release by "smart" nanomaterials. The most heavily explored strategies include (1) pH, (2) enzymes, (3) redox, (4) magnetic, and (5) light-triggered release.

  20. Radioactive iodine releases from nuclear power plant, (2)

    International Nuclear Information System (INIS)

    Naritomi, Mitsuo

    1974-01-01

    Internal radiation dose through the respiratory intake of fission products is predominantly due to radioactive iodine not only at the time of reactor accidents but also in normal operation of nuclear facilities. Technological studies in this field have thus been quite active to this day. With the rapid advance of nuclear power generation in recent years, the efforts to reduce environmental release of radioactive iodine and to enhance environmental safety are all the more emphasized. Experiences in the Japan Atomic Energy Research Institute during past about six years are described concerning the radioactive iodine release to the atmosphere in 131 I production and the measures taken to reduce the release. Then, problems are expounded regarding the radioactive iodine release at the time of reactor accidents and in spent fuel reprocessing. (Mori, K.)

  1. Alizarin Complexone Functionalized Mesoporous Silica Nanoparticles: A Smart System Integrating Glucose-Responsive Double-Drugs Release and Real-Time Monitoring Capabilities.

    Science.gov (United States)

    Zou, Zhen; He, Dinggeng; Cai, Linli; He, Xiaoxiao; Wang, Kemin; Yang, Xue; Li, Liling; Li, Siqi; Su, Xiaoya

    2016-04-06

    The outstanding progress of nanoparticles-based delivery systems capable of releasing hypoglycemic drugs in response to glucose has dramatically changed the outlook of diabetes management. However, the developed glucose-responsive systems have not offered real-time monitoring capabilities for accurate quantifying hypoglycemic drugs released. In this study, we present a multifunctional delivery system that integrates both delivery and monitoring issues using glucose-triggered competitive binding scheme on alizarin complexone (ALC) functionalized mesoporous silica nanoparticles (MSN). In this system, ALC is modified on the surface of MSN as the signal reporter. Gluconated insulin (G-Ins) is then introduced onto MSN-ALC via benzene-1,4-diboronic acid (BA) mediated esterification reaction, where G-Ins not only blocks drugs inside the mesopores but also works as a hypoglycemic drug. In the absence of glucose, the sandwich-type boronate ester structure formed by BA binding to the diols of ALC and G-Ins remains intact, resulting in an fluorescence emission peak at 570 nm and blockage of pores. Following a competitive binding, the presence of glucose cause the dissociation of boronate ester between ALC and BA, which lead to the pores opening and disappearance of fluorescence. As proof of concept, rosiglitazone maleate (RSM), an insulin-sensitizing agent, was doped into the MSN to form a multifunctional MSN (RSM@MSN-ALC-BA-Ins), integrating with double-drugs loading, glucose-responsive performance, and real-time monitoring capability. It has been demonstrated that the glucose-responsive release behaviors of insulin and RSM in buffer or in human serum can be quantified in real-time through evaluating the changes of fluorescence signal. We believe that this developed multifunctional system can shed light on the invention of a new generation of smart nanoformulations for optical diagnosis, individualized treatment, and noninvasive monitoring of diabetes management.

  2. Release fraction of PWR after severe accidents. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    Aziz, M; El-Messeiry, A M [National Center for Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    Fission fragments and gases are emitted after accidents as a result of core meltdown and core concrete interactions. These aerosols are transported and fill the reactor containment. With increasing the pressure above pressure design bases, a failure of containment may occur and subsequently these aerosols will release into the external environment leading to a source term of radioactivity that affects the safety of workers and public. The amount of aerosol which escapes to the environment can be described by the release fraction which is defined as the total accumulated aerosol which initially enters the containment. The factors that affect the release fraction is studied, and the aerosol dynamics equation is used to model the release of aerosol to the outside atmosphere. These factors are containment pressure, failure time,break area, the size of aerosol particle. It found that early failure time and higher pressure increase the release fraction, also the release faction is affected by the area and the aerosol particle size. 7 figs., 2 tabs.

  3. Release fraction of PWR after severe accidents. Vol. 4

    International Nuclear Information System (INIS)

    Aziz, M.; El-Messeiry, A.M.

    1996-01-01

    Fission fragments and gases are emitted after accidents as a result of core meltdown and core concrete interactions. These aerosols are transported and fill the reactor containment. With increasing the pressure above pressure design bases, a failure of containment may occur and subsequently these aerosols will release into the external environment leading to a source term of radioactivity that affects the safety of workers and public. The amount of aerosol which escapes to the environment can be described by the release fraction which is defined as the total accumulated aerosol which initially enters the containment. The factors that affect the release fraction is studied, and the aerosol dynamics equation is used to model the release of aerosol to the outside atmosphere. These factors are containment pressure, failure time,break area, the size of aerosol particle. It found that early failure time and higher pressure increase the release fraction, also the release faction is affected by the area and the aerosol particle size. 7 figs., 2 tabs

  4. Continuous-release formulation for environmental doses to moving receptors

    International Nuclear Information System (INIS)

    Piepho, M.G.

    1981-01-01

    Atmospheric dispersion models frequently assume a puff release or several puff releases, each of which are described separately. A dispersion model should better describe a continuous release as more puffs are assumed, but the computational cost and bookkeeping difficulty increases with additional puffs. A new formulism is derived in this work which replaces the puff approximation. With the new continuous release formulation, radioactive dose calculations to moving receptors are more accurately calculated without any great additional computation. There are several advantages of a continuous release formulation. With this formulation, a dose rate to a moving receptor is calculated as a function of time. The dose-rate will increase (decrease) as the bulk of the release gets closer (farther) to (from) the receptor which is at position x(t), y(t). The receptor may follow any x, y trajectory as a function of time, and the dose rate will be calculated along the path

  5. Predicting hydrocarbon release from soil

    International Nuclear Information System (INIS)

    Poppendieck, D.; Loehr, R.C.

    2002-01-01

    'Full text:' The remediation of hazardous chemicals from soils can be a lengthy and costly process. As a result, recent regulatory initiatives have focused on risk-based corrective action (RBCA) approaches. Such approaches attempt to identify the amount of chemical that can be left at a site with contaminated soil and still be protective of human health and the environment. For hydrocarbons in soils to pose risk to human heath and the environment, the hydrocarbons must be released from the soil and accessible to microorganisms, earthworms, or other higher level organisms. The sorption of hydrocarbons to soil can reduce the availability of the hydrocarbon to receptors. Typically in soils and sediments, there is an initial fast release of a hydrocarbon from the soil to the aqueous phase followed by a slower release of the remaining hydrocarbon to the aqueous phase. The rate and extent of slow release can influence aqueous hydrocarbon concentrations and the fate and transport of hydrocarbons in the subsurface. Once the fast fraction of the chemical has been removed from the soil, the remaining fraction of a chemical may desorb at a rate that natural mechanisms can attenuate the released hydrocarbon. Hence, active remediation may be needed only until the fast fraction has been removed. However, the fast fraction is a soil and chemical specific parameter. This presentation will present a tier I type protocol that has been developed to quickly estimate the fraction of hydrocarbons that are readily released from the soil matrix to the aqueous phase. Previous research in our laboratory and elsewhere has used long-term desorption (four months) studies to determine the readily released fraction. This research shows that a single short-term (less than two weeks) batch extraction procedure provides a good estimate of the fast released fraction derived from long-term experiments. This procedure can be used as a tool to rapidly evaluate the release and bioavailability of

  6. COMMERCIAL SNF ACCIDENT RELEASE FRACTIONS

    Energy Technology Data Exchange (ETDEWEB)

    S.O. Bader

    1999-10-18

    The purpose of this design analysis is to specify and document the total and respirable fractions for radioactive materials that are released from an accident event at the Monitored Geologic Repository (MGR) involving commercial spent nuclear fuel (CSNF) in a dry environment. The total and respirable release fractions will be used to support the preclosure licensing basis for the MGR. The total release fraction is defined as the fraction of total CSNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. The radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses. This subset of the total release fraction is referred to as the respirable release fraction. Potential accidents may involve waste forms that are characterized as either bare (unconfined) fuel assemblies or confined fuel assemblies. The confined CSNF assemblies at the MGR are contained in shipping casks, canisters, or disposal containers (waste packages). In contrast to the bare fuel assemblies, the container that confines the fuel assemblies has the potential of providing an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. However, this analysis will not take credit for this additional bamer and will establish only the total release fractions for bare unconfined CSNF assemblies, which may however be

  7. COMMERCIAL SNF ACCIDENT RELEASE FRACTIONS

    International Nuclear Information System (INIS)

    S.O. Bader

    1999-01-01

    The purpose of this design analysis is to specify and document the total and respirable fractions for radioactive materials that are released from an accident event at the Monitored Geologic Repository (MGR) involving commercial spent nuclear fuel (CSNF) in a dry environment. The total and respirable release fractions will be used to support the preclosure licensing basis for the MGR. The total release fraction is defined as the fraction of total CSNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. The radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses. This subset of the total release fraction is referred to as the respirable release fraction. Potential accidents may involve waste forms that are characterized as either bare (unconfined) fuel assemblies or confined fuel assemblies. The confined CSNF assemblies at the MGR are contained in shipping casks, canisters, or disposal containers (waste packages). In contrast to the bare fuel assemblies, the container that confines the fuel assemblies has the potential of providing an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. However, this analysis will not take credit for this additional bamer and will establish only the total release fractions for bare unconfined CSNF assemblies, which may however be

  8. Precision Neutron Time-of-Flight Detectors Provide Insight into NIF Implosion Dynamics

    Science.gov (United States)

    Schlossberg, David; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R.; Moore, A. S.; Waltz, C. S.

    2017-10-01

    During inertial confinement fusion, higher-order moments of neutron time-of-flight (nToF) spectra can provide essential information for optimizing implosions. The nToF diagnostic suite at the National Ignition Facility (NIF) was recently upgraded to include novel, quartz Cherenkov detectors. These detectors exploit the rapid Cherenkov radiation process, in contrast with conventional scintillator decay times, to provide high temporal-precision measurements that support higher-order moment analyses. Preliminary measurements have been made on the NIF during several implosions and initial results are presented here. Measured line-of-sight asymmetries, for example in ion temperatures, will be discussed. Finally, advanced detector optimization is shown to advance accessible physics, with possibilities for energy discrimination, gamma source identification, and further reduction in quartz response times. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.

  9. Matrix and reservoir-type multipurpose vaginal rings for controlled release of dapivirine and levonorgestrel.

    Science.gov (United States)

    Boyd, Peter; Fetherston, Susan M; McCoy, Clare F; Major, Ian; Murphy, Diarmaid J; Kumar, Sandeep; Holt, Jonathon; Brimer, Andrew; Blanda, Wendy; Devlin, Brid; Malcolm, R Karl

    2016-09-10

    A matrix-type silicone elastomer vaginal ring providing 28-day continuous release of dapivirine (DPV) - a lead candidate human immunodeficiency virus type 1 (HIV-1) microbicide compound - has recently demonstrated moderate levels of protection in two Phase III clinical studies. Here, next-generation matrix and reservoir-type silicone elastomer vaginal rings are reported for the first time offering simultaneous and continuous in vitro release of DPV and the contraceptive progestin levonorgestrel (LNG) over a period of between 60 and 180days. For matrix-type vaginal rings comprising initial drug loadings of 100, 150 or 200mg DPV and 0, 16 or 32mg LNG, Day 1 daily DPV release values were between 4132 and 6113μg while Day 60 values ranged from 284 to 454μg. Daily LNG release ranged from 129 to 684μg on Day 1 and 2-91μg on Day 60. Core-type rings comprising one or two drug-loaded cores provided extended duration of in vitro release out to 180days, and maintained daily drug release rates within much narrower windows (either 75-131μg/day or 37-66μg/day for DPV, and either 96-150μg/day or 37-57μg/day for LNG, depending on core ring configuration and ignoring initial lag release effect for LNG) compared with matrix-type rings. The data support the continued development of these devices as multi-purpose prevention technologies (MPTs) for HIV prevention and long-acting contraception. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Accelerated in vitro release testing method for naltrexone loaded PLGA microspheres.

    Science.gov (United States)

    Andhariya, Janki V; Choi, Stephanie; Wang, Yan; Zou, Yuan; Burgess, Diane J; Shen, Jie

    2017-03-30

    The objective of the present study was to develop a discriminatory and reproducible accelerated release testing method for naltrexone loaded parenteral polymeric microspheres. The commercially available naltrexone microsphere product (Vivitrol ® ) was used as the testing formulation in the in vitro release method development, and both sample-and-separate and USP apparatus 4 methods were investigated. Following an in vitro drug stability study, frequent media replacement and addition of anti-oxidant in the release medium were used to prevent degradation of naltrexone during release testing at "real-time" (37°C) and "accelerated" (45°C), respectively. The USP apparatus 4 method was more reproducible than the sample-and-separate method. In addition, the accelerated release profile obtained using USP apparatus 4 had a shortened release duration (within seven days), and good correlation with the "real-time" release profile. Lastly, the discriminatory ability of the developed accelerated release method was assessed using compositionally equivalent naltrexone microspheres with different release characteristics. The developed accelerated USP apparatus 4 release method was able to detect differences in the release characteristics of the prepared naltrexone microspheres. Moreover, a linear correlation was observed between the "real-time" and accelerated release profiles of all the formulations investigated, suggesting that the release mechanism(s) may be similar under both conditions. These results indicate that the developed accelerated USP apparatus 4 method has the potential to be an appropriate fast quality control tool for long-acting naltrexone PLGA microspheres. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Flavour release of aldehydes and diacetyl in oil/water systems

    DEFF Research Database (Denmark)

    Haahr, Anne-Mette; Bredie, W. L. P.; Stahnke, Louise Heller

    2000-01-01

    from the pure oil. The release over time for diacetyl and (E,E)-2,4-hexadienal showed a linear relationship in all systems. The other compounds followed an exponential relationship between the time and the fraction released in the aqueous systems. It was demonstrated that the release of the volatile...... compounds was dependent on the chain length, the degree of unsaturation as well as the characteristics of the model system. (C) 2000 Elsevier Science Ltd. All rights reserved.......The concentration- and time-dependent release of three C-6-aldehydes, six C-9-aldehydes and diacetyl was studied in model systems. The systems were water, rapeseed oil and oil-in-water emulsions. Dynamic headspace sampling was used to collect the volatile compounds. In the concentration...

  12. MCNP Version 6.2 Release Notes

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Christopher John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bull, Jeffrey S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Solomon, C. J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Forrest B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McKinney, Gregg Walter [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rising, Michael Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martz, Roger Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry G. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cox, Lawrence James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zukaitis, Anthony J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Armstrong, J. C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Forster, Robert Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Casswell, Laura [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-02-05

    Monte Carlo N-Particle or MCNP® is a general-purpose Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP Version 6.2 follows the MCNP6.1.1 beta version and has been released in order to provide the radiation transport community with the latest feature developments and bug fixes for MCNP. Since the last release of MCNP major work has been conducted to improve the code base, add features, and provide tools to facilitate ease of use of MCNP version 6.2 as well as the analysis of results. These release notes serve as a general guide for the new/improved physics, source, data, tallies, unstructured mesh, code enhancements and tools. For more detailed information on each of the topics, please refer to the appropriate references or the user manual which can be found at http://mcnp.lanl.gov. This release of MCNP version 6.2 contains 39 new features in addition to 172 bug fixes and code enhancements. There are still some 33 known issues the user should familiarize themselves with (see Appendix).

  13. Global analysis and parametric dependencies for potential unintended hydrogen-fuel releases

    Energy Technology Data Exchange (ETDEWEB)

    Harstad, Kenneth; Bellan, Josette [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, M/S 125-109, Pasadena, CA 91109-8099 (United States)

    2006-01-01

    Global, simplified analyses of gaseous-hydrogen releases from a high-pressure vessel and liquid-hydrogen pools are conducted for two purposes: (1) establishing order-of-magnitude values of characteristic times and (2) determining parametric dependencies of these characteristic times on the physical properties of the configuration and on the thermophysical properties of hydrogen. According to the ratio of the characteristic release time to the characteristic mixing time, two limiting configurations are identified: (1) a rich cloud exists when this ratio is much smaller than unity, and (2) a jet exists when this ratio is much larger than unity. In all cases, it is found that the characteristic release time is proportional to the total released mass and inversely proportional to a characteristic area. The approximate size, convection velocity, and circulation time of unconfined burning-cloud releases scale with the cloud mass at powers 1/3, 1/6, and 1/6, respectively, multiplied by an appropriately dimensional constant; the influence of cross flow can only be important if its velocity exceeds that of internal convection. It is found that the fireball lifetime is approximately the maximum of the release time and thrice the convection-associated characteristic time. Transition from deflagration to detonation can occur only if the size of unconfined clouds exceeds by a factor of O(10) that of a characteristic detonation cell, which ranges from 0.015 m under stoichiometric conditions to approximately 1 m under extreme rich/lean conditions. For confined vapor pockets, transition occurs only for pocket sizes larger than the cell size. In jets, the release time is inversely proportional to the initial vessel pressure and has a square root dependence on the vessel temperature. Jet velocities are a factor of 10 larger than convective velocities in fireballs and combustion is possible only in the subsonic, downstream region where entrainment may occur.

  14. Time-resolved diffraction of shock-released SiO2 and diaplectic glass formation

    International Nuclear Information System (INIS)

    Gleason, A. E.; Bolme, C. A.; Lee, H. J.; Nagler, B.

    2017-01-01

    Understanding how rock-forming minerals transform under shock loading is critical for modeling collisions between planetary bodies, interpreting the significance of shock features in minerals and for using them as diagnostic indicators of impact conditions, such as shock pressure. To date, our understanding of the formation processes experienced by shocked materials is based exclusively on ex situ analyses of recovered samples. Formation mechanisms and origins of commonly observed mesoscale material features, such as diaplectic (i.e., shocked) glass, remain therefore controversial and unresolvable. Here in this paper we show in situ pump-probe X-ray diffraction measurements on fused silica crystallizing to stishovite on shock compression and then converting to an amorphous phase on shock release in only 2.4 ns from 33.6 GPa. Recovered glass fragments suggest permanent densification. These observations of real-time diaplectic glass formation attest that it is a back-transformation product of stishovite with implications for revising traditional shock metamorphism stages.

  15. Precision Departure Release Capability (PDRC) Overview and Results: NASA to FAA Research Transition

    Science.gov (United States)

    Engelland, Shawn; Davis, Tom.

    2013-01-01

    NASA researchers developed the Precision Departure Release Capability (PDRC) concept to improve the tactical departure scheduling process. The PDRC system is comprised of: 1) a surface automation system that computes ready time predictions and departure runway assignments, 2) an en route scheduling automation tool that uses this information to estimate ascent trajectories to the merge point and computes release times and, 3) an interface that provides two-way communication between the two systems. To minimize technology transfer issues and facilitate its adoption by TMCs and Frontline Managers (FLM), NASA developed the PDRC prototype using the Surface Decision Support System (SDSS) for the Tower surface automation tool, a research version of the FAA TMA (RTMA) for en route automation tool and a digital interface between the two DSTs to facilitate coordination.

  16. Experimental composite guidance conduits for peripheral nerve repair: An evaluation of ion release

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.F. [Department of Biological Sciences and Medical Engineering Design and Innovation Centre, Cork Institute of Technology, Cork (Ireland); Coughlan, A. [Inamori School of Engineering, Alfred University, Alfred, NY. 14802 (United States); O' Shea, H. [Department of Biological Sciences and Medical Engineering Design and Innovation Centre, Cork Institute of Technology, Cork (Ireland); Towler, M.R. [Inamori School of Engineering, Alfred University, Alfred, NY. 14802 (United States); Kehoe, S., E-mail: sharonkehoe@dal.ca [Department of Applied Oral Sciences, Dalhousie University, Halifax, NS, B3H 4R2 (Canada); School of Biomedical Engineering, Dalhousie University, Halifax, NS, B3H 4R2 (Canada); Boyd, D., E-mail: d.boyd@dal.ca [Department of Applied Oral Sciences, Dalhousie University, Halifax, NS, B3H 4R2 (Canada); School of Biomedical Engineering, Dalhousie University, Halifax, NS, B3H 4R2 (Canada)

    2012-08-01

    Poly (lactide-co-glycolide) (PLGA) - Pluronic F127 - glass composites have demonstrated excellent potential, from the perspective of controlled mechanical properties and cytocompatibility, for peripheral nerve regeneration. In addition to controlling the mechanical properties and cytotoxicity for such composite devices, the glass component may mediate specific responses upon implantation via degradation in the physiological environment and release of constituent elements. However, research focused on quantifying the release levels of such therapeutic ions from these experimental medical devices has been limited. To redress the balance, this paper explores the ion release profiles for Si{sup 4+}, Ca{sup 2+}, Na{sup +}, Zn{sup 2+}, and Ce{sup 4+} from experimental composite nerve guidance conduits (CNGC) comprising PLGA (at 12.5, and 20 wt.%), F127 (at 0, 2.5 and 5 wt.%) and various loadings of Si-Ca-Na-Zn-Ce glass (at 20 and 40 wt.%) for incubation periods of up to 28 days. The concentration of each ion, at various time points, was determined using Inductively Coupled Plasma-Atomic Emission Spectrometry (Perkin Elmer Optima 3000). It was observed that the Si{sup 4+}, Na{sup +}, Ca{sup 2+}, Zn{sup 2+} release from CNGCs in this study ranged from 0.22 to 6.477 ppm, 2.307 to 3.277 ppm, 40 to 119 ppm, and 45 to 51 ppm, respectively. The Ce{sup 4+} concentrations were under the minimum detection limits for the ICP instrument utilized. The results indicate that the ion release levels may be appropriate to mediate therapeutic effects with respect to peripheral nerve regeneration. The data generated in this paper provides requisite evidence to optimize composition for pre-clinical evaluation of the experimental composite. - Graphical abstract: Highlights: Black-Right-Pointing-Pointer Time-dependent degradation studies of PLGA/glass composite nerve guidance conduits (NGCs). Black-Right-Pointing-Pointer Si{sup 4+}, Na{sup +}, Ca{sup 2+} and Zn{sup 2+} release levels for the

  17. Integrating Behavioral Health into Pediatric Primary Care: Implications for Provider Time and Cost.

    Science.gov (United States)

    Gouge, Natasha; Polaha, Jodi; Rogers, Rachel; Harden, Amy

    2016-12-01

    Integrating a behavioral health consultant (BHC) into primary care is associated with improved patient outcomes, fewer medical visits, and increased provider satisfaction; however, few studies have evaluated the feasibility of this model from an operations perspective. Specifically, time and cost have been identified as barriers to implementation. Our study aimed to examine time spent, patient volume, and revenue generated during days when the on-site BHC was available compared with days when the consultant was not. Data were collected across a 10-day period when a BHC provided services and 10 days when she was not available. Data included time stamps of patient direct care; providers' direct reports of problems raised; and a review of medical and administrative records, including billing codes and reimbursement. This study took place in a rural, stand-alone private pediatric primary care practice. The participants were five pediatric primary care providers (PCPs; two doctors of medicine, 1 doctor of osteopathy, 2 nurse practitioners) and two supervised doctoral students in psychology (BHCs). Pediatric patients (N = 668) and their parents also participated. On days when a BHC was present, medical providers spent 2 fewer minutes on average for every patient seen, saw 42% more patients, and collected $1142 more revenue than on days when no consultant was present. The time savings demonstrated on days when the consultant was available point to the efficiency and potential financial viability of this model. These results have important implications for the feasibility of hiring behavioral health professionals in a fee-for-service system. They have equally useful implications for the utility of moving to a bundled system of care in which collaborative practice is valued.

  18. Training Materials for Release 3

    DEFF Research Database (Denmark)

    Wake, Jo Dugstad; Hansen, Cecilie; Debus, Kolja

    This document, D7.4 – training materials for release 3, provides an overview of the training material for version 3 of the NEXT-TELL tools and methods. Previous documents submitted as part of work package 7, which is about teacher training, are D7.1 – Training Concept, D7.2 – Training Materials...... for Release 1 and D7.3 – Training Materials for Release 2. D7.4 builds on D7.1 and D7.2 and D7.3. D7.4 contains further development of previous work within WP7, essentially a revised theoretical approach to the teacher training, and expansion of the notion of tool training. The media in use have been expanded...

  19. Modeling the wind-fields of accidental releases with an operational regional forecast model

    International Nuclear Information System (INIS)

    Albritton, J.R.; Lee, R.L.; Sugiyama, G.

    1995-01-01

    The Atmospheric Release Advisory Capability (ARAC) is an operational emergency preparedness and response organization supported primarily by the Departments of Energy and Defense. ARAC can provide real-time assessments of atmospheric releases of radioactive materials at any location in the world. ARAC uses robust three-dimensional atmospheric transport and dispersion models, extensive geophysical and dose-factor databases, meteorological data-acquisition systems, and an experienced staff. Although it was originally conceived and developed as an emergency response and assessment service for nuclear accidents, the ARAC system has been adapted to also simulate non-radiological hazardous releases. For example, in 1991 ARAC responded to three major events: the oil fires in Kuwait, the eruption of Mt. Pinatubo in the Philippines, and the herbicide spill into the upper Sacramento River in California. ARAC's operational simulation system, includes two three-dimensional finite-difference models: a diagnostic wind-field scheme, and a Lagrangian particle-in-cell transport and dispersion scheme. The meteorological component of ARAC's real-time response system employs models using real-time data from all available stations near the accident site to generate a wind-field for input to the transport and dispersion model. Here we report on simulation studies of past and potential release sites to show that even in the absence of local meteorological observational data, readily available gridded analysis and forecast data and a prognostic model, the Navy Operational Regional Atmospheric Prediction System, applied at an appropriate grid resolution can successfully simulate complex local flows

  20. Calculation of tritium release from reactor's stack

    International Nuclear Information System (INIS)

    Akhadi, M.

    1996-01-01

    Method for calculation of tritium release from nuclear to environment has been discussed. Part of gas effluent contain tritium in form of HTO vapor released from reactor's stack was sampled using silica-gel. The silica-gel was put in the water to withdraw HTO vapor absorbed by silica-gel. Tritium concentration in the water was measured by liquid scintillation counter of Aloka LSC-703. Tritium concentration in the gas effluent and total release of tritium from reactor's stack during certain interval time were calculated using simple mathematic formula. This method has examined for calculation of tritium release from JRR-3M's stack of JAERI, Japan. From the calculation it was obtained the value of tritium release as much as 4.63 x 10 11 Bq during one month. (author)

  1. Mechanisms of iodine release from iodoapatite in aqueous solution

    Science.gov (United States)

    Zhang, Z.; Wang, J.

    2017-12-01

    Immobilization of iodine-129 with waste forms in geological setting is challenging due to its extremely long half-life and high volatility in the environment. To evaluate the long-term performance of waste form, it is imperative to determine the release mechanism of iodine hosted in the waste form materials. This study investigated the iodine released from apatite structured waste form Pb9.85 (VO4)6 I1.7 to understand how diffusion and dissolution control the durability of apatite waste form. A standard semi-dynamic leach test was adopted in this study. Samples were exposed in fresh leachant periodically and the leachant was replaced after each interval. Each experiment was carried out in cap-sealed Teflon vessels under constant temperature (e.g. 90 °C). ICP-MS analysis on the reacted leachates shows that Pb and V were released constantly and congruently with the stoichiometric ratio of Pb/V. However, iodine release is incongruent and time dependent. The iodine release rate starts significantly higher than the corresponding stoichiometric value and gradually decreases, approaching the stoichiometric value. Therefore, a dual-mode mechanism is proposed to account for the iodine release from apatite, which is dominated by short-term diffusion and long-term dissolution processes. Additional tests show that the element release rates depend on a number of test parameters, including sample surface to solution volume ratio (m-1), interval (day), temperature (°C), and solution pH. This study provides a quantitative characterization of iodine release mechanism. The activation energy of iodine leaching 21±1.6 kJ/mol was obtained by varying the test temperature. At the test conditions of to neutral pH and 90 °C, the long-term iodine release rate 3.3 mg/(m2 • day) is projected by normalizing sample surface area to solution volume ratio (S/V) to 1.0 m-1 and interval to 1 day. These findings demonstrate i) the feasibility of our approach to quantify the release mechanism

  2. GEWEX SRB Shortwave Release 4

    Science.gov (United States)

    Cox, S. J.; Stackhouse, P. W., Jr.; Mikovitz, J. C.; Zhang, T.

    2017-12-01

    The NASA/GEWEX Surface Radiation Budget (SRB) project produces shortwave and longwave surface and top of atmosphere radiative fluxes for the 1983-near present time period. Spatial resolution is 1 degree. The new Release 4 uses the newly processed ISCCP HXS product as its primary input for cloud and radiance data. The ninefold increase in pixel number compared to the previous ISCCP DX allows finer gradations in cloud fraction in each grid box. It will also allow higher spatial resolutions (0.5 degree) in future releases. In addition to the input data improvements, several important algorithm improvements have been made since Release 3. These include recalculated atmospheric transmissivities and reflectivities yielding a less transmissive atmosphere. The calculations also include variable aerosol composition, allowing for the use of a detailed aerosol history from the Max Planck Institut Aerosol Climatology (MAC). Ocean albedo and snow/ice albedo are also improved from Release 3. Total solar irradiance is now variable, averaging 1361 Wm-2. Water vapor is taken from ISCCP's nnHIRS product. Results from GSW Release 4 are presented and analyzed. Early comparison to surface measurements show improved agreement.

  3. Methane release

    International Nuclear Information System (INIS)

    Seifert, M.

    1999-01-01

    The Swiss Gas Industry has carried out a systematic, technical estimate of methane release from the complete supply chain from production to consumption for the years 1992/1993. The result of this survey provided a conservative value, amounting to 0.9% of the Swiss domestic output. A continuation of the study taking into account new findings with regard to emission factors and the effect of the climate is now available, which provides a value of 0.8% for the target year of 1996. These results show that the renovation of the network has brought about lower losses in the local gas supplies, particularly for the grey cast iron pipelines. (author)

  4. Commercial SNF Accident Release Fractions

    Energy Technology Data Exchange (ETDEWEB)

    J. Schulz

    2004-11-05

    container that confines the fuel assemblies could provide an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. This analysis, however, does not take credit for the additional barrier and establishes only the total release fractions for bare unconfined intact commercial SNF assemblies, which may be conservatively applied to confined intact commercial I SNF assemblies.

  5. Commercial SNF Accident Release Fractions

    International Nuclear Information System (INIS)

    Schulz, J.

    2004-01-01

    container that confines the fuel assemblies could provide an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. This analysis, however, does not take credit for the additional barrier and establishes only the total release fractions for bare unconfined intact commercial SNF assemblies, which may be conservatively applied to confined intact commercial I SNF assemblies

  6. Drug-releasing shape-memory polymers - the role of morphology, processing effects, and matrix degradation.

    Science.gov (United States)

    Wischke, Christian; Behl, Marc; Lendlein, Andreas

    2013-09-01

    Shape-memory polymers (SMPs) have gained interest for temporary drug-release systems that should be anchored in the body by self-sufficient active movements of the polymeric matrix. Based on the so far published scientific literature, this review highlights three aspects that require particular attention when combining SMPs with drug molecules: i) the defined polymer morphology as required for the shape-memory function, ii) the strong effects that processing conditions such as drug-loading methodologies can have on the drug-release pattern from SMPs, and iii) the independent control of drug release and degradation by their timely separation. The combination of SMPs with a drug-release functionality leads to multifunctional carriers that are an interesting technology for pharmaceutical sciences and can be further expanded by new materials such as thermoplastic SMPs or temperature-memory polymers. Experimental studies should include relevant molecules as (model) drugs and provide a thermomechanical characterization also in an aqueous environment, report on the potential effect of drug type and loading levels on the shape-memory functionality, and explore the potential correlation of polymer degradation and drug release.

  7. Barrier and operational risk analysis of hydrocarbon releases (BORA-Release)

    International Nuclear Information System (INIS)

    Sklet, Snorre; Vinnem, Jan Erik; Aven, Terje

    2006-01-01

    This paper presents results from a case study carried out on an offshore oil and gas production platform with the purpose to apply and test BORA-Release, a method for barrier and operational risk analysis of hydrocarbon releases. A description of the BORA-Release method is given in Part I of the paper. BORA-Release is applied to express the platform specific hydrocarbon release frequencies for three release scenarios for selected systems and activities on the platform. The case study demonstrated that the BORA-Release method is a useful tool for analysing the effect on the release frequency of safety barriers introduced to prevent hydrocarbon releases, and to study the effect on the barrier performance of platform specific conditions of technical, human, operational, and organisational risk influencing factors (RIFs). BORA-Release may also be used to analyse the effect on the release frequency of risk reducing measures

  8. Emergency response capability for pollutant releases to streams and rivers

    International Nuclear Information System (INIS)

    Buckner, M.R.; Hayes, D.W.; Watts, J.R.

    1975-01-01

    Stream-river models have been developed which provide an accurate prediction of normal and accidental pollutant releases to streams and rivers. Stream parameters are being developed for the Savannah River Plant streams and the Savannah River to allow quick response in case of an accidental release of radioactive material. These data are stored on permanent disk storage for quick access via the JOSHUA operating system. This system provides an efficient and flexible emergency response capability for pollutant releases to streams and rivers

  9. Operational control of material release and discharges from nuclear power plant

    International Nuclear Information System (INIS)

    Szabo, I. C.; Ranga, T.; Daroczi, L.; Deme, S.; Kerekes, A.

    2003-01-01

    The operational control of radioactive materials during atmospheric release and aquatic discharge from nuclear power plant is a licensing criterion for NPPs. Originally at the Paks NPP the release control was based on activity limits for four groups of elements. These groups were noble gases, long living radio-aerosols, radioiodine and radiostrontium for atmospheric release and specified activity limit for beta emitters, strontium and tritium for aquatic discharge into Danube. These groups were controlled with proper sampling and/or measuring instrumentation. The limit for atmospheric release was given as a 30-day moving average, for liquid discharges the annual limit was stipulated. The new release and discharge limitation system is based on the environmental dose limitation. The dose constraint for Paks NPP is 90 Sv/year of the critical group for all release pathways and the investigation dose limit is equal to 27 Sv/year. The regulation did not subdivide the dose limit for atmospheric and liquid components but for operational control subdivision of dose limits for atmospheric release and aquatic discharge and shorter time period (one day-one month) seems to be useful. The subdivision can be based on past release data and/or previous activity limits. To satisfy dose below the investigation dose limit there should be a proper operation control level for each separately measured component and pathway belonging to reasonable time interval significantly shorter than one year. The main task of the NPP staff is elaboration of reasonable control levels and reference time intervals for different radionuclide and element groups to be used in operational control. Operational control levels are based on measured daily or monthly release rates. In case of noble gases, aerosols and iodine the daily release rates have several sharp peaks per year. Operational control levels give opportunity to detect these peaks for internal investigation purposes. Investigation release limits

  10. Iron oxide nanoparticle-based magnetic resonance method to monitor release kinetics from polymeric particles with high resolution.

    Science.gov (United States)

    Chan, Minnie; Schopf, Eric; Sankaranarayanan, Jagadis; Almutairi, Adah

    2012-09-18

    A new method to precisely monitor rapid release kinetics from polymeric particles using super paramagnetic iron oxide nanoparticles, specifically by measuring spin-spin relaxation time (T(2)), is reported. Previously, we have published the formulation of logic gate particles from an acid-sensitive poly-β-aminoester ketal-2 polymer. Here, a series of poly-β-aminoester ketal-2 polymers with varying hydrophobicities were synthesized and used to formulate particles. We attempted to measure fluorescence of released Nile red to determine whether the structural adjustments could finely tune the release kinetics in the range of minutes to hours; however, this standard technique did not differentiate each release rate of our series. Thus, a new method based on encapsulation of iron oxide nanoparticles was developed, which enabled us to resolve the release kinetics of our particles. Moreover, the kinetics matched the relative hydrophobicity order determined by octanol-water partition coefficients. To the best of our knowledge, this method provides the highest resolution of release kinetics to date.

  11. Historical Doses from Tritiated Water and Tritiated Hydrogen Gas Released to the Atmosphere from Lawrence Livermore National Laboratory (LLNL). Part 5. Accidental Releases

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, S

    2007-08-15

    Over the course of fifty-three years, LLNL had six acute releases of tritiated hydrogen gas (HT) and one acute release of tritiated water vapor (HTO) that were too large relative to the annual releases to be included as part of the annual releases from normal operations detailed in Parts 3 and 4 of the Tritium Dose Reconstruction (TDR). Sandia National Laboratories/California (SNL/CA) had one such release of HT and one of HTO. Doses to the maximally exposed individual (MEI) for these accidents have been modeled using an equation derived from the time-dependent tritium model, UFOTRI, and parameter values based on expert judgment. All of these acute releases are described in this report. Doses that could not have been exceeded from the large HT releases of 1965 and 1970 were calculated to be 43 {micro}Sv (4.3 mrem) and 120 {micro}Sv (12 mrem) to an adult, respectively. Two published sets of dose predictions for the accidental HT release in 1970 are compared with the dose predictions of this TDR. The highest predicted dose was for an acute release of HTO in 1954. For this release, the dose that could not have been exceeded was estimated to have been 2 mSv (200 mrem), although, because of the high uncertainty about the predictions, the likely dose may have been as low as 360 {micro}Sv (36 mrem) or less. The estimated maximum exposures from the accidental releases were such that no adverse health effects would be expected. Appendix A lists all accidents and large routine puff releases that have occurred at LLNL and SNL/CA between 1953 and 2005. Appendix B describes the processes unique to tritium that must be modeled after an acute release, some of the time-dependent tritium models being used today, and the results of tests of these models.

  12. Controlled release of tetracycline-HCl from halloysite-polymer composite films.

    Science.gov (United States)

    Ward, Christopher J; Song, Shang; Davis, Edward W

    2010-10-01

    The first direct comparison between two common methods for loading halloysite with a small molecule for controlled release is presented. While the methods differ in the degree of simplicity, they provide essentially the same level of loading and release kinetics. A tentative explanation of the "burst" effect often seen in the release of low molecular weight molecules from halloysite is provided. The ability of halloysite to mediate the release rate of a water soluble drug, tetracycline, from solution cast polyvinyl alcohol and polymethyl methacrylate films was evaluated. In some films, montmorillonite was also incorporated. The addition of montmorillonite to solutions used to cast tetracycline containing films significantly reduced the release rate from the dried films. The same overall effect was seen when the drug was loaded into halloysite prior to preparation of the films. In both cases, the release was best fit with the simple Higuchi model. However, when montmorillonite was added to solutions of polyvinyl alcohol and drug loaded halloysite the release profiles were better fit by the Ritgar-Peppas model for anomalous transport. Release from polymethyl methacrylate was reduced by a factor of three by incorporating the drug in halloysite prior to producing the films.

  13. TIME-BASED COMPETITION IN THE SUPPLY-CHAIN: THE ROLE OF THE LOGISTICS SERVICE PROVIDERS

    Directory of Open Access Journals (Sweden)

    Judit OLÁH

    2018-05-01

    Full Text Available Among the service industries, the analysis logistics as an academic field which has a great influence on firms’ creation of value and competitiveness, and within this the analysis of firms providing logistics services (3PLP, has become more relevant than in previous years. Among the expectations of logistics service providers, and among the sources of competitive advantage, are timeliness and flexibility, which can only be handled and measured together, because of the integration of services. At the same time, when supply chains (not corporations compete with each other, we must create the opportunity to manage chains beyond company boundaries. Our aim is to investigate the time-related problems of supply chains (and sections and logistics service providers, and their consequences and solutions. We have found that the development of time factors which appear and can be measured in the realization of logistics services contributes to the competitiveness of a logistics service company. The performance provided by companies that are integrated into the supply chain’s member companies and operate as flexible logistics service providers can have a significant impact on the (full operation and efficiency of the supply chain.

  14. Developmental checkpoints and feedback circuits time insect maturation

    DEFF Research Database (Denmark)

    Rewitz, Kim Furbo; Yamanaka, Naoki; O'Connor, Michael B.

    2013-01-01

    as external cues, to time production and release of ecdysone. Based on results discussed here, we suggest that developmental progression to adulthood is controlled by checkpoints that regulate the genetic timing program enabling it to adapt to different environmental conditions. These checkpoints utilize...... a number of signaling pathways to modulate ecdysone production in the prothoracic gland. Release of ecdysone activates an autonomous cascade of both feedforward and feedback signals that determine the duration of the ecdysone pulse at each developmental transitions. Conservation of the genetic mechanisms...... that coordinate the juvenile-adult transition suggests that insights from the fruit fly Drosophila will provide a framework for future investigation of developmental timing in metazoans....

  15. Zero-order release of poorly water-soluble drug from polymeric films made via aqueous slurry casting.

    Science.gov (United States)

    Zhang, Lu; Alfano, Joy; Race, Doran; Davé, Rajesh N

    2018-05-30

    In spite of significant recent interest in polymeric films containing poorly water-soluble drugs, dissolution mechanism of thicker films has not been investigated. Consequently, release mechanisms of poorly water-soluble drugs from thicker hydroxypropyl methylcellulose (HPMC) films are investigated, including assessing thickness above which they exhibit zero-order drug release. Micronized, surface modified particles of griseofulvin, a model drug of BSC class II, were incorporated into aqueous slurry-cast films of different thicknesses (100, 500, 1000, 1500 and 2000 μm). Films 1000 μm and thicker were formed by either stacking two or more layers of ~500 μm, or forming a monolithic thick film. Compared to monolithic thick films, stacked films required simpler manufacturing process (easier casting, short drying time) and resulted in better critical quality attributes (appearance, uniformity of thickness and drug per unit area). Both the film forming approaches exhibited similar release profiles and followed the semi-empirical power law. As thickness increased from 100 μm to 2000 μm, the release mechanism changed from Fickian diffusion to zero-order release for films ≥1000 μm. The diffusional power law exponent, n, achieved value of 1, confirming zero-order release, whereas the percentage drug release varied linearly with sample surface area, and sample thickness due to fixed sample diameter. Thus, multi-layer hydrophilic polymer aqueous slurry-cast thick films containing poorly water-soluble drug particles provide a convenient dosage form capable of zero-order drug release with release time modulated through number of layers. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Dynamics of shear-induced ATP release from red blood cells.

    Science.gov (United States)

    Wan, Jiandi; Ristenpart, William D; Stone, Howard A

    2008-10-28

    Adenosine triphosphate (ATP) is a regulatory molecule for many cell functions, both for intracellular and, perhaps less well known, extracellular functions. An important example of the latter involves red blood cells (RBCs), which help regulate blood pressure by releasing ATP as a vasodilatory signaling molecule in response to the increased shear stress inside arterial constrictions. Although shear-induced ATP release has been observed widely and is believed to be triggered by deformation of the cell membrane, the underlying mechanosensing mechanism inside RBCs is still controversial. Here, we use an in vitro microfluidic approach to investigate the dynamics of shear-induced ATP release from human RBCs with millisecond resolution. We demonstrate that there is a sizable delay time between the onset of increased shear stress and the release of ATP. This response time decreases with shear stress, but surprisingly does not depend significantly on membrane rigidity. Furthermore, we show that even though the RBCs deform significantly in short constrictions (duration of increased stress <3 ms), no measurable ATP is released. This critical timescale is commensurate with a characteristic membrane relaxation time determined from observations of the cell deformation by using high-speed video. Taken together our results suggest a model wherein the retraction of the spectrin-actin cytoskeleton network triggers the mechanosensitive ATP release and a shear-dependent membrane viscosity controls the rate of release.

  17. Release strategies for making transferable semiconductor structures, devices and device components

    Science.gov (United States)

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  18. The atmospheric release advisory capability (ARAC): A federal emergency response capability

    International Nuclear Information System (INIS)

    Dickerson, M.H.; Sullivan, T.J.

    1988-03-01

    The Atmospheric Release Capability (ARAC) is a Department of Energy (DOE)-sponsored emergency-response service set up to provide real-time prediction of the dose levels and the extent of surface contamination resulting from a broad range of possible occurrences (accidents, spills, extortion threats involving nuclear material, reentry of nuclear-powered satellites, and atmospheric nuclear tests) that could involve the release of airborne radioactive material. During the past decade, ARAC has responded to more than 150 real-time situations, including exercises. The most notable responses include the Three Mile Island accident in Pennsylvania, the Titan II missile accident in Arkansas, the reentry of the USSR's COSMOS-954 into the atmosphere over Canada, the accidental release of uranium hexafluoride from the Sequoyah Facility accident in Oklahoma, and, most recently, the Chernobyl reactor accident in the Soviet Union. ARAC currently supports the emergency-preparedness plans at 50 Department of Defense (DOD) and DOE sites within the US and also responds to accidents that happen elsewhere. Our ARAC center serves as the focal point for data acquisition, data analysis and assessments during a response, using a computer-based communication network to acquire real-time weather data from the accident site and the surrounding region, as well as pertinent accident information. Its three-dimensional computer models for atmospheric dispersion, MATHEW and ADPIC, digest all this information and produce the predictions used in accident assessment. 9 refs., 6 figs., 1 tab

  19. Mimicking Neurotransmitter Release in Chemical Synapses via Hysteresis Engineering in MoS2 Transistors.

    Science.gov (United States)

    Arnold, Andrew J; Razavieh, Ali; Nasr, Joseph R; Schulman, Daniel S; Eichfeld, Chad M; Das, Saptarshi

    2017-03-28

    Neurotransmitter release in chemical synapses is fundamental to diverse brain functions such as motor action, learning, cognition, emotion, perception, and consciousness. Moreover, improper functioning or abnormal release of neurotransmitter is associated with numerous neurological disorders such as epilepsy, sclerosis, schizophrenia, Alzheimer's disease, and Parkinson's disease. We have utilized hysteresis engineering in a back-gated MoS 2 field effect transistor (FET) in order to mimic such neurotransmitter release dynamics in chemical synapses. All three essential features, i.e., quantal, stochastic, and excitatory or inhibitory nature of neurotransmitter release, were accurately captured in our experimental demonstration. We also mimicked an important phenomenon called long-term potentiation (LTP), which forms the basis of human memory. Finally, we demonstrated how to engineer the LTP time by operating the MoS 2 FET in different regimes. Our findings could provide a critical component toward the design of next-generation smart and intelligent human-like machines and human-machine interfaces.

  20. An approach for estimating toxic releases of H2S-containing natural gas.

    Science.gov (United States)

    Jianwen, Zhang; Da, Lei; Wenxing, Feng

    2014-01-15

    China is well known being rich in sulfurous natural gas with huge deposits widely distributed all over the country. Due to the toxic nature, the release of hydrogen sulfide-containing natural gas from the pipelines intends to impose serious threats to the human, society and environment around the release sources. CFD algorithm is adopted to simulate the dispersion process of gas, and the results prove that Gaussian plume model is suitable for determining the affected region of the well blowout of sulfide hydrogen-containing natural gas. In accordance with the analysis of release scenarios, the present study proposes a new approach for estimating the risk of hydrogen sulfide poisoning hazards, as caused by sulfide-hydrogen-containing natural gas releases. Historical accident-statistical data from the EGIG (European Gas Pipeline Incident Data Group) and the Britain Gas Transco are integrated into the approach. Also, the dose-load effect is introduced to exploit the hazards' effects by two essential parameters - toxic concentration and exposure time. The approach was applied to three release scenarios occurring on the East-Sichuan Gas Transportation Project, and the individual risk and societal risk are classified and discussed. Results show that societal risk varies significantly with different factors, including population density, distance from pipeline, operating conditions and so on. Concerning the dispersion process of hazardous gas, available safe egress time was studied from the perspective of individual fatality risks. The present approach can provide reliable support for the safety management and maintenance of natural gas pipelines as well as evacuations that may occur after release incidents. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Health care providers under pressure: making the most of challenging times.

    Science.gov (United States)

    Davis, Scott B; Robinson, Phillip J

    2010-01-01

    Whether the slowing economic recovery, tight credit markets, increasing costs, or the uncertainty surrounding health care reform, the health care industry faces some sizeable challenges. These factors have put considerable strain on the industry's traditional financing options that the industry has relied on in the past--bonds, banks, finance companies, private equity, venture capital, real estate investment trusts, private philanthropy, and grants. At the same time, providers are dealing with rising costs, lower reimbursement rates, shrinking demand for elective procedures, higher levels of charitable care and bad debt, and increased scrutiny of tax-exempt hospitals. Providers face these challenges against a back ground of uncertainty created by health care reform.

  2. Validation of software releases for CMS

    International Nuclear Information System (INIS)

    Gutsche, Oliver

    2010-01-01

    The CMS software stack currently consists of more than 2 Million lines of code developed by over 250 authors with a new version being released every week. CMS has setup a validation process for quality assurance which enables the developers to compare the performance of a release to previous releases and references. The validation process provides the developers with reconstructed datasets of real data and MC samples. The samples span the whole range of detector effects and important physics signatures to benchmark the performance of the software. They are used to investigate interdependency effects of all CMS software components and to find and fix bugs. The release validation process described here is an integral part of CMS software development and contributes significantly to ensure stable production and analysis. It represents a sizable contribution to the overall MC production of CMS. Its success emphasizes the importance of a streamlined release validation process for projects with a large code basis and significant number of developers and can function as a model for future projects.

  3. Canadian pollutant releases and transfers : NPRI data 1998

    International Nuclear Information System (INIS)

    2001-03-01

    A large, two-sided fold-out poster showing pollution hotspots throughout Canada, has been released by the Canadian Institute for Environmental Law and Policy (CIELAP). The poster is based on the maps and tables of the National Pollutant Release Inventory (NPRI) 1998. It presents the top on-site releases and off-site transfers of pollutants by facilities across Canada, and provides a summary of releases, transfers and recycling of pollutants by province. The map depicts the facilities with the five largest quantities of individual pollutants released to each medium, i. e. water, air, land, underground. The crude oil and gas, other utilities, primary metal, paper and chemical industrial sectors are responsible for the largest on-site releases, while the business services, fabricated metal. primary metal and chemical industrial sectors account for the largest off-site transfers. Twenty-five of the 176 substances whose releases and transfers are reported under the NPRI are classified as 'toxic' or 'carcinogenic'. tabs., maps

  4. 38 CFR 36.4327 - Release of security.

    Science.gov (United States)

    2010-07-01

    ... this section or in paragraphs (e) and (f) of § 36.4822, the holder shall not release a lien or other right in or to real property held as security for a guaranteed or insured loan, or grant a fee or other... approval of the Secretary, release the lien on a portion of the property securing the loan provided: (i...

  5. Flavor release measurement by atmospheric pressure chemical ionization ion trap mass spectrometry, construction of interface and mathematical modeling of release profiles

    DEFF Research Database (Denmark)

    Haahr, Anne-Mette; Madsen, Henrik; Smedsgaard, Jørn

    2003-01-01

    and the method can be used to measure breath from the nose. A mathematical model of the data was developed to give a quantitative method for description and characterization of the release of flavor compounds. The release profiles consisted of two sequences, one for a chewing period, and one for a phasing out...... process. The proposed method for modeling provided a reasonable description of the release process. In addition to flavor compounds, this new interface and mathematical application could provide information on chemicals in the human breath which could be interesting, for example, within medical diagnosis....... with that of the flavor detection threshold. An application study on the release of menthone and menthol from chewing gum by a group of six test persons was performed. Flavored chewing gum was used as a model matrix because of the long chewing periods and the simplicity of the system. It is concluded that the interface...

  6. Moss antheridia are desiccation tolerant: Rehydration dynamics influence sperm release in Bryum argenteum.

    Science.gov (United States)

    Stark, Lloyd R; McLetchie, D Nicholas; Greenwood, Joshua L; Eppley, Sarah M

    2016-05-01

    Free-living sperm of mosses are known to be partially desiccation tolerant. We hypothesized that mature moss antheridia should also tolerate desiccation and that rehydration to partial turgor (prehydration) or rehydration to full turgor (rehydration) before immersion in water is required for full recovery from any damaging effects of prior desiccation. Bryum argenteum (silvery-thread moss) was grown in continuous culture for several months, produced mature perigonia (clusters of antheridia), and these were subjected to a slow rate of drying (∼36 h from full turgor to desiccation) and equilibration with 50% relative humidity. Perigonia were prehydrated (exposed to a saturated atmosphere) or rehydrated (planted upright in saturated media) for 0, 45, 90, 135, 180, and 1440 min, then immersed in sterile water. Time to first sperm mass release, number of antheridia releasing sperm masses, and the integrity of the first sperm mass released were assessed. Rehydration of dried antheridia for at least 3 h before immersion in water resulted in antheridia functioning similar to control undried antheridia. Compared with rehydration, prehydration was not effective in the recovery of antheridia from desiccation. For the first time, moss antheridia are shown to be fully desiccation tolerant at a functional level, capable of releasing fully functional sperm following a slow drying event provided the antheridia are allowed to rehydrate at least 3 h before immersion in water. © 2016 Botanical Society of America.

  7. Underground Nuclear Explosions and Release of Radioactive Noble Gases

    Science.gov (United States)

    Dubasov, Yuri V.

    2010-05-01

    Over a period in 1961-1990 496 underground nuclear tests and explosions of different purpose and in different rocks were conducted in the Soviet Union at Semipalatinsk and anovaya Zemlya Test Sites. A total of 340 underground nuclear tests were conducted at the Semipalatinsk Test Site. One hundred seventy-nine explosions (52.6%) among them were classified as these of complete containment, 145 explosions (42.6%) as explosions with weak release of radioactive noble gases (RNG), 12 explosions (3.5%) as explosions with nonstandard radiation situation, and four excavation explosions with ground ejection (1.1%). Thirty-nine nuclear tests had been conducted at the Novaya Zemlya Test Site; six of them - in shafts. In 14 tests (36%) there were no RNG release. Twenty-three tests have been accompanied by RNG release into the atmosphere without sedimental contamination. Nonstandard radiation situation occurred in two tests. In incomplete containment explosions both early-time RNG release (up to ~1 h) and late-time release from 1 to 28 h after the explosion were observed. Sometimes gas release took place for several days, and it occurred either through tunnel portal or epicentral zone, depending on atmospheric air temperature.

  8. MoS2/Pt nanocomposite-functionalized microneedle for real-time monitoring of hydrogen peroxide release from living cells.

    Science.gov (United States)

    Zhou, Jin-Xiu; Tang, Li-Na; Yang, Fan; Liang, Feng-Xia; Wang, Hua; Li, Yu-Tao; Zhang, Guo-Jun

    2017-11-06

    This work describes the adaptive use of a conventional stainless steel acupuncture needle as the electrode substrate for construction of a molybdenum disulfide (MoS 2 ) and platinum nanoparticles (PtNPs) layer-modified microneedle sensor for real-time monitoring of hydrogen peroxide (H 2 O 2 ) release from living cells. To construct the nanocomposite-functionalized microneedle, the needle surface was first coated with a gold film by ion sputtering to enhance the conductivity. Subsequently, an electrochemical deposition method was successfully employed to deposit MoS 2 nanosheet and Pt nanoparticles on the needle tip as the sensing interface. Electrochemical study demonstrated that the MoS 2 /PtNPs nanocomposite-modified needle exhibited excellent catalytic performance and low over-potential toward the reduction of H 2 O 2 . Not only did the microneedle achieve a wide linear range from 1 to 100 μmol L -1 with a limit of detection down to 0.686 μmol L -1 , but it also realized the highly specific detection of H 2 O 2 . Owing to these remarkable analytical advantages, the prepared microneedle was applied to determine H 2 O 2 release from living cells with satisfactory results. The MoS 2 /PtNPs nanocomposite-functionalized microneedle sensor is simple and affordable, and can serve as a promising electrochemical nonenzymatic sensing platform. Moreover, this superfine needle sensor shows great potential for real-time monitoring of reactive oxygen species in vivo with minimal damage.

  9. Using Time-Driven Activity-Based Costing as a Key Component of the Value Platform: A Pilot Analysis of Colonoscopy, Aortic Valve Replacement and Carpal Tunnel Release Procedures

    Science.gov (United States)

    Martin, Jacob A.; Mayhew, Christopher R.; Morris, Amanda J.; Bader, Angela M.; Tsai, Mitchell H.; Urman, Richard D.

    2018-01-01

    Background Time-driven activity-based costing (TDABC) is a methodology that calculates the costs of healthcare resources consumed as a patient moves along a care process. Limited data exist on the application of TDABC from the perspective of an anesthesia provider. We describe the use of TDABC, a bottom-up costing strategy and financial outcomes for three different medical-surgical procedures. Methods In each case, a multi-disciplinary team created process maps describing the care delivery cycle for a patient encounter using the TDABC methodology. Each step in a process map delineated an activity required for delivery of patient care. The resources (personnel, equipment and supplies) associated with each step were identified. A per minute cost for each resource expended was generated, known as the capacity cost rate, and multiplied by its time requirement. The total cost for an episode of care was obtained by adding the cost of each individual resource consumed as the patient moved along a clinical pathway. Results We built process maps for colonoscopy in the gastroenterology suite, calculated costs of an aortic valve replacement by comparing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR) techniques, and determined the cost of carpal tunnel release in an operating room versus an ambulatory procedure room. Conclusions TDABC is central to the value-based healthcare platform. Application of TDABC provides a framework to identify process improvements for health care delivery. The first case demonstrates cost-savings and improved wait times by shifting some of the colonoscopies scheduled with an anesthesiologist from the main hospital to the ambulatory facility. In the second case, we show that the deployment of an aortic valve via the transcatheter route front loads the costs compared to traditional, surgical replacement. The last case demonstrates significant cost savings to the healthcare system associated with re

  10. Physical and Release Properties of Metronidazole Suppositories ...

    African Journals Online (AJOL)

    80, sodium salicylate and methylcellulose as adjuvants. The setting time, solidification point and melting range of the suppositories were determined, along with their crushing strength, disintegration time and the time for 80% of metronidazole to be released from the suppositories (t80). Results: The ranking of setting time for ...

  11. Zippered release from polymer-gated carbon nanotubes

    KAUST Repository

    Mashat, Afnan

    2012-01-01

    A thermosensitive drug delivery system based on polymer-gated carbon nanotubes (CNTs) that are loaded with the anticancer drug doxorubicin (DOX) is herein reported. The development of carbon nanotubes for various biomedical applications is the research focus of many research groups and holds great promise. The major drawback of these materials is the toxicity that is associated with conjugated carbon systems. Functionalization of CNTs with polymers has proved very successful in lowering the toxicity and improving the pharmacokinetic profile. In this work, CNTs are coated with polyethylenimine (PEI) and polyvinyl alcohol (PVA) via the "zipper effect" that provides both support and control over drug release. PEI/PVA provides excellent support to increase DOX loading on the nanocarrier. The system is controlled by changes in temperature due to the complexation (low temperature) and decomplexation (high temperature) of PEI and PVA via hydrogen bonding. The release of DOX was tested in three cell lines (Lung fibroblast (LF), Breast Adenocarcinoma (BA), and HeLa). It was further tested in primary cell lines (Human Dermal Fibroblast adult (HDFa) and Human Dermal Fibroblast neonatal (HDFn)). When the bonds between PEI and PVA are decomplexed at high temperature (≥40 °C), drug release was observed as verified by fluorescence microscopy. There was no drug release at room temperature (25 °C) and a slow release at normal body temperature (37 °C). This system represents a promising method for incorporating stimuli triggered polymer-gated CNTs in future controlled release applications. © 2012 The Royal Society of Chemistry.

  12. Solubility and fluoride release in ionomers and compomers.

    Science.gov (United States)

    Bertacchini, S M; Abate, P F; Blank, A; Baglieto, M F; Macchi, R L

    1999-03-01

    The degree of solubility and the fluoride release of glass-ionomer cements and "compomers" were determined as a function of time. Three conventional glass-ionomer cements, three hybrid ionomers, and two compomers were included in the study. Disk-shaped specimens were prepared and immersed in a lactic acid solution. Solubility was evaluated from determinations of loss of mass as a function of time. To evaluate fluoride release, similar specimens were immersed in 50 mL of deionized water to which 50 mL of buffer solution was added. A fluoride ion detector was used to read the concentration of fluoride ion in the overall solution at different times after immersion. Material and time factors had a significant influence on results. The compomers showed less corrosion and fluoride release than the ionomers. Some correlation was found between solubility and fluoride leakage values. Components of both the ionomers and compomers that were studied can dissolve in water. The materials leak fluoride ions in amounts that differ according to the characteristics of the individual products.

  13. Elastic energy release in great earthquakes and eruptions

    Directory of Open Access Journals (Sweden)

    Agust eGudmundsson

    2014-05-01

    Full Text Available The sizes of earthquakes are measured using well-defined, measurable quantities such as seismic moment and released (transformed elastic energy. No similar measures exist for the sizes of volcanic eruptions, making it difficult to compare the energies released in earthquakes and eruptions. Here I provide a new measure of the elastic energy (the potential mechanical energy associated with magma chamber rupture and contraction (shrinkage during an eruption. For earthquakes and eruptions, elastic energy derives from two sources: (1 the strain energy stored in the volcano/fault zone before rupture, and (2 the external applied load (force, pressure, stress, displacement on the volcano/fault zone. From thermodynamic considerations it follows that the elastic energy released or transformed (dU during an eruption is directly proportional to the excess pressure (pe in the magma chamber at the time of rupture multiplied by the volume decrease (-dVc of the chamber, so that . This formula can be used as a basis for a new eruption magnitude scale, based on elastic energy released, which can be related to the moment-magnitude scale for earthquakes. For very large eruptions (>100 km3, the volume of the feeder-dike is negligible, so that the decrease in chamber volume during an eruption corresponds roughly to the associated volume of erupted materials , so that the elastic energy is . Using a typical excess pressures of 5 MPa, it is shown that the largest known eruptions on Earth, such as the explosive La Garita Caldera eruption (27-28 million years ago and largest single (effusive Colombia River basalt lava flows (15-16 million years ago, both of which have estimated volumes of about 5000 km3, released elastic energy of the order of 10EJ. For comparison, the seismic moment of the largest earthquake ever recorded, the M9.5 1960 Chile earthquake, is estimated at 100 ZJ and the associated elastic energy release at 10EJ.

  14. 49 CFR 236.16 - Electric lock, main track releasing circuit.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock, main track releasing circuit. 236... Rules and Instructions: All Systems General § 236.16 Electric lock, main track releasing circuit. When an electric lock releasing circuit is provided on the main track to permit a train or an engine to...

  15. Controlled Release from Recombinant Polymers

    Science.gov (United States)

    Price, Robert; Poursaid, Azadeh; Ghandehari, Hamidreza

    2014-01-01

    Recombinant polymers provide a high degree of molecular definition for correlating structure with function in controlled release. The wide array of amino acids available as building blocks for these materials lend many advantages including biorecognition, biodegradability, potential biocompatibility, and control over mechanical properties among other attributes. Genetic engineering and DNA manipulation techniques enable the optimization of structure for precise control over spatial and temporal release. Unlike the majority of chemical synthetic strategies used, recombinant DNA technology has allowed for the production of monodisperse polymers with specifically defined sequences. Several classes of recombinant polymers have been used for controlled drug delivery. These include, but are not limited to, elastin-like, silk-like, and silk-elastinlike proteins, as well as emerging cationic polymers for gene delivery. In this article, progress and prospects of recombinant polymers used in controlled release will be reviewed. PMID:24956486

  16. A GTPase chimera illustrates an uncoupled nucleotide affinity and release rate, Providing insight into the activation mechanism

    DEFF Research Database (Denmark)

    Guilfoyle, Amy P.; Deshpande, Chandrika N.; Font Sadurni, Josep

    2014-01-01

    , biophysical studies on both the eukaryotic Gα proteins and the GTPase domain (NFeoB) of prokaryotic FeoB proteins have revealed conformational changes in the G5 loop that accompany nucleotide binding and release. However, it is unclear whether this conformational change in the G5 loop is a prerequisite...

  17. Ririe Dam Release Test Assessment

    Science.gov (United States)

    2013-06-01

    Notes HEC - RAS Location Station (ft) Observation Notes 1420 Ririe Dam Ririe Dam 119,880 Gates opened and initial release started. 1455 115th St...16°F air temperature. Table A2. Observations made on 11 February 2013. Time Location Notes HEC - RAS Location Station (ft) Observation Notes...ERDC/CRREL TR-13-10 52 Time Location Notes HEC - RAS Location Station (ft) Observation Notes Travel Time* (sec) Vel.** (fps) 1224 5th

  18. Controlled release studies of calcium alginate hydrogels

    International Nuclear Information System (INIS)

    Rendevski, S.; Andonovski, A.; Mahmudi, N.

    2012-01-01

    Controlled release of substances in many cases may be achieved from calcium alginate hydrogels. In this research, the time dependence of the mass of released model substance bovine serum albumin (BSA) from calcium alginate spherical hydrogels of three different types (G/M ratio) have been investigated. The hydrogels were prepared with the drop-wise method of sodium alginate aqueous solutions with concentration of 0.02 g/cm 3 with 0.01 g/cm 3 BSA and a gelling water bath of chitosan in 0.2 M CH 3 COOH/0.4 M CH 3 COONa with added 0.2 M CaCl 2 .The hydrogel structures were characterized by dynamic light scattering and scanning electron microscopy. The controlled release studies were conducted by UV-Vis spectrophotometry of the released medium with p H=7 at 37 °C. The results showed that the model of osmotic pumping is the dominant mechanism of the release. Also, large dependences of the release profile on the homogeneity of the hydrogels were found. (Author)

  19. Controlled release of curcumin from poly(HEMA-MAPA) membrane.

    Science.gov (United States)

    Caka, Müşerref; Türkcan, Ceren; Aktaş Uygun, Deniz; Uygun, Murat; Akgöl, Sinan; Denizli, Adil

    2017-05-01

    In this work, poly(HEMA-MAPA) membranes were prepared by UV-polymerization technique. These membranes were characterized by SEM, FTIR, and swelling studies. Synthesized membranes had high porous structure. These membranes were used for controlled release of curcumin which is already used as folk remedy and used as drug for some certain diseases and cancers. Curcumin release was investigated for various pHs and temperatures. Optimum drug release yield was found to be as 70% at pH 7.4 and 37 °C within 2 h period. Time-depended release of curcumin was also investigated and its slow release from the membrane demonstrated within 48 h.

  20. Metal release from simulated fixed orthodontic appliances.

    Science.gov (United States)

    Hwang, C J; Shin, J S; Cha, J Y

    2001-10-01

    Most orthodontic appliances and archwires are stainless steel or nickel-titanium (NiTi) alloys that can release metal ions, with saliva as the medium. To measure metal released from the fixed orthodontic appliances currently in use, we fabricated simulated fixed orthodontic appliances that corresponded to half of the maxillary arch and soaked them in 50 mL of artificial saliva (pH 6.75 +/- 0.15, 37 degrees C) for 3 months. We used brackets, tubes, and bands made by Tomy (Tokyo, Japan). Four groups were established according to the appliance manufacturer and the type of metal in the .016 x .022-in archwires. Groups A and B were stainless steel archwires from Ormco (Glendora, Calif) and Dentaurum (Ispringen, Germany), respectively, and groups C and D were both NiTi archwires with Ormco's copper NiTi and Tomy's Bioforce sentalloy, respectively. Stainless steel archwires were heat treated in an electric furnace at 500 degrees C for 1 minute and quenched in water. We measured the amount of metal released from each group by immersion time. Our conclusions were as follows: (1) there was no increase in the amount of chromium released after 4 weeks in group A, 2 weeks in group B, 3 weeks in group C, and 8 weeks in group D; (2) there was no increase in the amount of nickel released after 2 weeks in group A, 3 days in group B, 7 days in group C, and 3 weeks in group D; and (3) there was no increase in the amount of iron released after 2 weeks in group A, 3 days in group B, and 1 day in groups C and D. In our 3-month-long investigation, we saw a decrease in metal released as immersion time increased.

  1. Controlled release system for ametryn using polymer microspheres: Preparation, characterization and release kinetics in water

    International Nuclear Information System (INIS)

    Grillo, Renato; Pereira, Anderson do Espirito Santo; Ferreira Silva de Melo, Nathalie; Porto, Raquel Martins; Feitosa, Leandro Oliveira; Tonello, Paulo Sergio; Dias Filho, Newton L.; Rosa, Andre Henrique; Lima, Renata; Fraceto, Leonardo Fernandes

    2011-01-01

    The purpose of this work was to develop a modified release system for the herbicide ametryn by encapsulating the active substance in biodegradable polymer microparticles produced using the polymers poly(hydroxybutyrate) (PHB) or poly(hydroxybutyrate-valerate) (PHBV), in order to both improve the herbicidal action and reduce environmental toxicity. PHB or PHBV microparticles containing ametryn were prepared and the efficiencies of herbicide association and loading were evaluated, presenting similar values of approximately 40%. The microparticles were characterized by scanning electron microscopy (SEM), which showed that the average sizes of the PHB and PHBV microparticles were 5.92 ± 0.74 μm and 5.63 ± 0.68 μm, respectively. The ametryn release profile was modified when it was encapsulated in the microparticles, with slower and more sustained release compared to the release profile of pure ametryn. When ametryn was associated with the PHB and PHBV microparticles, the amount of herbicide released in the same period of time was significantly reduced, declining to 75% and 87%, respectively. For both types of microparticle (PHB and PHBV) the release of ametryn was by diffusion processes due to anomalous transport (governed by diffusion and relaxation of the polymer chains), which did not follow Fick's laws of diffusion. The results presented in this paper are promising, in view of the successful encapsulation of ametryn in PHB or PHBV polymer microparticles, and indications that this system may help reduce the impacts caused by the herbicide, making it an environmentally safer alternative.

  2. Bioactive Glass Nanoparticles as a New Delivery System for Sustained 5-Fluorouracil Release: Characterization and Evaluation of Drug Release Mechanism

    Directory of Open Access Journals (Sweden)

    Abeer M. El-Kady

    2015-01-01

    Full Text Available Bioactive glass nanoparticles were synthesized and tested for the first time as a new delivery system for sustained 5-fluorouracil (5-FU release. They were characterized by TEM, DTA, TGA, and FT-IR. The porosity % and specific surface area of glass nanoparticles were 85.59% and 378.36 m2/g, respectively. The in vitro bioactivity evaluation confirmed that bioactive glass disks prepared from these nanoparticles could induce hydroxyapatite layer over their surfaces in simulated body fluid. The in vitro drug release experiment indicated that glass nanoparticles could serve as long-term local delivery vehicles for sustained 5-FU release. The release profile of 5-FU showed an initial fast release stage followed by a second stage of slower release. The initial burst release of 5-FU in the first day was about 23% (28.92 mg·L−1 of the total amount of loaded 5-FU, while the final cumulative percentage of the 5-FU released after 32 days was about 45.6% (57.31 mg·L−1 of the total amount of loaded 5-FU. The application of different mathematical models indicated that 5-FU was released by diffusion controlled mechanism and suggested that its release rate was dependent on glass particles dissolution, changes of surface area as well as diameter of glass particles, and concentration of loaded drug.

  3. Drug release from core-shell PVA/silk fibroin nanoparticles fabricated by one-step electrospraying.

    Science.gov (United States)

    Cao, Yang; Liu, Fengqiu; Chen, Yuli; Yu, Tao; Lou, Deshuai; Guo, Yuan; Li, Pan; Wang, Zhigang; Ran, Haitao

    2017-09-20

    Silk fibroin (SF), a FDA-approved natural protein, is renowned for its great biocompatibility, biodegradability, and mechanical properties. SF-based nanoparticles provide new options for drug delivery with their tunable drug loading and release properties. To take advantage of the features of carrier polymers, we present a one-step electrospraying method that combines SF, polyvinyl alcohol (PVA) and therapeutic drugs without an emulsion process. A distinct core-shell structure was obtained with the PVA core and silk shell after the system was properly set up. The model drug, doxorubicin, was encapsulated in the core with a greater than 90% drug encapsulation efficiency. Controllable drug release profiles were achieved by alternating the PVA/SF ratio. Although the initial burst release of the drug was minimized by the SF coating, a large number of drug molecules remained entrapped by the carrier polymers. To promote and trigger drug release on demand, low intensity focused ultrasound (US) was applied. The US was especially advantageous for accelerating the drug diffusion and release. The apoptotic activity of MDA-MB-231 cells incubated with drug-loaded nanoparticles was found to increase with time. In addition, we also observed PVA/SF nanoparticles that could elicit a drug release in response to pH.

  4. Amount and timing of permafrost carbon release in response to climate warming

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Kevin; Zhang, Tingjun; Barrett, Andrew P. (National Snow and Ice Data Center, Cooperative Inst. for Research in Environmental Sciences, Univ. of Colorado at Boulder, Boulder (United States)), e-mail: kevin.schaefer@nsidc.org; Bruhwiler, Lori (National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Boulder (United States))

    2011-04-15

    The thaw and release of carbon currently frozen in permafrost will increase atmospheric CO{sub 2} concentrations and amplify surface warming to initiate a positive permafrost carbon feedback (PCF) on climate.We use surface weather from three global climate models based on the moderate warming, A1B Intergovernmental Panel on Climate Change emissions scenario and the SiBCASA land surface model to estimate the strength and timing of the PCF and associated uncertainty. By 2200, we predict a 29-59% decrease in permafrost area and a 53-97 cm increase in active layer thickness. By 2200, the PCF strength in terms of cumulative permafrost carbon flux to the atmosphere is 190 +- 64 Gt C. This estimate may be low because it does not account for amplified surface warming due to the PCF itself and excludes some discontinuous permafrost regions where SiBCASA did not simulate permafrost. We predict that the PCF will change the arctic from a carbon sink to a source after the mid-2020s and is strong enough to cancel 42-88% of the total global land sink. The thaw and decay of permafrost carbon is irreversible and accounting for the PCF will require larger reductions in fossil fuel emissions to reach a target atmospheric CO{sub 2} concentration

  5. Benchmarking of fast-running software tools used to model releases during nuclear accidents

    Energy Technology Data Exchange (ETDEWEB)

    Devitt, P.; Viktorov, A., E-mail: Peter.Devitt@cnsc-ccsn.gc.ca, E-mail: Alex.Viktorov@cnsc-ccsn.gc.ca [Canadian Nuclear Safety Commission, Ottawa, ON (Canada)

    2015-07-01

    Fukushima highlighted the importance of effective nuclear accident response. However, its complexity greatly impacted the ability to provide timely and accurate information to national and international stakeholders. Safety recommendations provided by different national and international organizations varied notably. Such differences can partially be attributed to different methods used in the initial assessment of accident progression and the amount of radioactivity release.Therefore, a comparison of methodologies was undertaken by the NEA/CSNI and its highlights are presented here. For this project, the prediction tools used by various emergency response organizations for estimating the source terms and public doses were examined. Those organizations that have a capability to use such tools responded to a questionnaire describing each code's capabilities and main algorithms. Then the project's participants analyzed five accident scenarios to predict the source term, dispersion of releases and public doses. (author)

  6. Medicare Provider Utilization and Payment Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — CMS has released a series of publicly available data files that summarize the utilization and payments for procedures, services, and prescription drugs provided to...

  7. Recent salmon declines: a result of lost feeding opportunities due to bad timing?

    Directory of Open Access Journals (Sweden)

    Cedar M Chittenden

    Full Text Available As the timing of spring productivity blooms in near-shore areas advances due to warming trends in global climate, the selection pressures on out-migrating salmon smolts are shifting. Species and stocks that leave natal streams earlier may be favoured over later-migrating fish. The low post-release survival of hatchery fish during recent years may be in part due to static release times that do not take the timing of plankton blooms into account. This study examined the effects of release time on the migratory behaviour and survival of wild and hatchery-reared coho salmon (Oncorhynchus kisutch using acoustic and coded-wire telemetry. Plankton monitoring and near-shore seining were also conducted to determine which habitat and food sources were favoured. Acoustic tags (n = 140 and coded-wire tags (n = 266,692 were implanted into coho salmon smolts at the Seymour and Quinsam Rivers, in British Columbia, Canada. Differences between wild and hatchery fish, and early and late releases were examined during the entire lifecycle. Physiological sampling was also carried out on 30 fish from each release group. The smolt-to-adult survival of coho salmon released during periods of high marine productivity was 1.5- to 3-fold greater than those released both before and after, and the fish's degree of smoltification affected their downstream migration time and duration of stay in the estuary. Therefore, hatchery managers should consider having smolts fully developed and ready for release during the peak of the near-shore plankton blooms. Monitoring chlorophyll a levels and water temperature early in the spring could provide a forecast of the timing of these blooms, giving hatcheries time to adjust their release schedule.

  8. Comparative evaluation of the calcium release from mineral trioxide aggregate and its mixture with glass ionomer cement in different proportions and time intervals – An in vitro study

    Directory of Open Access Journals (Sweden)

    Surbhi Sawhney

    2015-10-01

    Conclusions: Adding GIC to improve the setting time and handling properties of the MTA powder can be detrimental to the calcium-releasing ability of the resultant mixture, depending on the proportion of GIC added. Adding MTA and GIC at a proportion of 2:1 by volume did not impact calcium release from the mixture. These findings should be verified through further clinical studies.

  9. The cholinergic system, circadian rhythmicity, and time memory

    NARCIS (Netherlands)

    Hut, R. A.; Van der Zee, E. A.

    2011-01-01

    This review provides an overview of the interaction between the mammalian cholinergic system and circadian system, and its possible role in time memory. Several studies made clear that circadian (daily) fluctuations in acetylcholine (ACh) release, cholinergic enzyme activity and cholinergic receptor

  10. Fission gas release from fuel at high burnup

    International Nuclear Information System (INIS)

    Meyer, R.O.; Beyer, C.E.; Voglewede, J.C.

    1978-03-01

    The release of fission gas from fuel pellets at high burnup is reviewed in the context of the safety analysis performed for reactor license applications. Licensing actions are described that were taken to correct deficient gas release models used in these safety analyses. A correction function, which was developed by the Nuclear Regulatory Commission staff and its consultants, is presented. Related information, which includes some previously unpublished data, is also summarized. The report thus provides guidance for the analysis of high burnup gas release in licensing situations

  11. Nature's Notebook Provides Phenology Observations for NASA Juniper Phenology and Pollen Transport Project

    Science.gov (United States)

    Luval, J. C.; Crimmins, T. M.; Sprigg, W. A.; Levetin, E.; Huete, A.; Nickovic, S.; Prasad, A.; Vukovic, A.; VandeWater, P. K.; Budge, A. M.; hide

    2014-01-01

    Phenology Network has been established to provide national wide observations of vegetation phenology. However, as the Network is still in the early phases of establishment and growth, the density of observers is not yet adequate to sufficiently document the phenology variability over large regions. Hence a combination of satellite data and ground observations can provide optimal information regarding juniperus spp. pollen phenology. MODIS data was to observe Juniperus supp. pollen phenology. The MODIS surface reflectance product provided information on the Juniper supp. cone formation and cone density. Ground based observational records of pollen release timing and quantities were used as verification. Approximately 10, 818 records of juniper phenology for male cone formation Juniperus ashei., J. monosperma, J. scopulorum, and J. pinchotti were reported by Nature's Notebook observers in 2013 These observations provided valuable information for the analysis of satellite images for developing the pollen concentration masks for input into the PREAM (Pollen REgional Atmospheric Model) pollen transport model. The combination of satellite data and ground observations allowed us to improve our confidence in predicting pollen release and spread, thereby improving asthma and allergy alerts.

  12. Probabilistic consequence model of accidenal or intentional chemical releases.

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y.-S.; Samsa, M. E.; Folga, S. M.; Hartmann, H. M.

    2008-06-02

    In this work, general methodologies for evaluating the impacts of large-scale toxic chemical releases are proposed. The potential numbers of injuries and fatalities, the numbers of hospital beds, and the geographical areas rendered unusable during and some time after the occurrence and passage of a toxic plume are estimated on a probabilistic basis. To arrive at these estimates, historical accidental release data, maximum stored volumes, and meteorological data were used as inputs into the SLAB accidental chemical release model. Toxic gas footprints from the model were overlaid onto detailed population and hospital distribution data for a given region to estimate potential impacts. Output results are in the form of a generic statistical distribution of injuries and fatalities associated with specific toxic chemicals and regions of the United States. In addition, indoor hazards were estimated, so the model can provide contingency plans for either shelter-in-place or evacuation when an accident occurs. The stochastic distributions of injuries and fatalities are being used in a U.S. Department of Homeland Security-sponsored decision support system as source terms for a Monte Carlo simulation that evaluates potential measures for mitigating terrorist threats. This information can also be used to support the formulation of evacuation plans and to estimate damage and cleanup costs.

  13. Integrated Scheduling of Production and Distribution with Release Dates and Capacitated Deliveries

    Directory of Open Access Journals (Sweden)

    Xueling Zhong

    2016-01-01

    Full Text Available This paper investigates an integrated scheduling of production and distribution model in a supply chain consisting of a single machine, a customer, and a sufficient number of homogeneous capacitated vehicles. In this model, the customer places a set of orders, each of which has a given release date. All orders are first processed nonpreemptively on the machine and then batch delivered to the customer. Two variations of the model with different objective functions are studied: one is to minimize the arrival time of the last order plus total distribution cost and the other is to minimize total arrival time of the orders plus total distribution cost. For the former one, we provide a polynomial-time exact algorithm. For the latter one, due to its NP-hard property, we provide a heuristic with a worst-case ratio bound of 2.

  14. Can Pulsed Electromagnetic Fields Trigger On-Demand Drug Release from High-Tm Magnetoliposomes?

    Directory of Open Access Journals (Sweden)

    Martina Nardoni

    2018-03-01

    Full Text Available Recently, magnetic nanoparticles (MNPs have been used to trigger drug release from magnetoliposomes through a magneto-nanomechanical approach, where the mechanical actuation of the MNPs is used to enhance the membrane permeability. This result can be effectively achieved with low intensity non-thermal alternating magnetic field (AMF, which, however, found rare clinic application. Therefore, a different modality of generating non-thermal magnetic fields has now been investigated. Specifically, the ability of the intermittent signals generated by non-thermal pulsed electromagnetic fields (PEMFS were used to verify if, once applied to high-transition temperature magnetoliposomes (high-Tm MLs, they could be able to efficiently trigger the release of a hydrophilic model drug. To this end, hydrophilic MNPs were combined with hydrogenated soybean phosphatidylcholine and cholesterol to design high-Tm MLs. The release of a dye was evaluated under the effect of PEMFs for different times. The MNPs motions produced by PEMF could effectively increase the bilayer permeability, without affecting the liposomes integrity and resulted in nearly 20% of release after 3 h exposure. Therefore, the current contribution provides an exciting proof-of-concept for the ability of PEMFS to trigger drug release, considering that PEMFS find already application in therapy due to their anti-inflammatory effects.

  15. Can Pulsed Electromagnetic Fields Trigger On-Demand Drug Release from High-Tm Magnetoliposomes?

    Science.gov (United States)

    Nardoni, Martina; Della Valle, Elena; Liberti, Micaela; Relucenti, Michela; Casadei, Maria Antonietta; Paolicelli, Patrizia; Apollonio, Francesca; Petralito, Stefania

    2018-03-27

    Recently, magnetic nanoparticles (MNPs) have been used to trigger drug release from magnetoliposomes through a magneto-nanomechanical approach, where the mechanical actuation of the MNPs is used to enhance the membrane permeability. This result can be effectively achieved with low intensity non-thermal alternating magnetic field (AMF), which, however, found rare clinic application. Therefore, a different modality of generating non-thermal magnetic fields has now been investigated. Specifically, the ability of the intermittent signals generated by non-thermal pulsed electromagnetic fields (PEMFS) were used to verify if, once applied to high-transition temperature magnetoliposomes (high-Tm MLs), they could be able to efficiently trigger the release of a hydrophilic model drug. To this end, hydrophilic MNPs were combined with hydrogenated soybean phosphatidylcholine and cholesterol to design high-Tm MLs. The release of a dye was evaluated under the effect of PEMFs for different times. The MNPs motions produced by PEMF could effectively increase the bilayer permeability, without affecting the liposomes integrity and resulted in nearly 20% of release after 3 h exposure. Therefore, the current contribution provides an exciting proof-of-concept for the ability of PEMFS to trigger drug release, considering that PEMFS find already application in therapy due to their anti-inflammatory effects.

  16. Extended-release naltrexone for pre-release prisoners: A randomized trial of medical mobile treatment

    Science.gov (United States)

    Gordon, Michael S.; Vocci, Frank J.; Fitzgerald, Terrence T.; O'Grady, Kevin E.; O'Brien, Charles P.

    2017-01-01

    Background Extended-release naltrexone (XR-NTX), is an effective treatment for opioid use disorder but is rarely initiated in US prisons or with criminal justice populations. Mobile treatment for chronic diseases have been implemented in a variety of settings. Mobile treatment may provide an opportunity to expand outreach to parolees to surmount barriers to traditional clinic treatment. Methods Male and female prisoners (240) with pre-incarceration histories of opioid use disorder who are within one month of release from prison will be enrolled in this randomized clinical trial. Participants are randomized to one of two study arms: 1) [XR-NTX-OTx] One injection of long-acting naltrexone in prison, followed by 6 monthly injections post-release at a community opioid treatment program; or 2) [XR-NTX+ MMTx] One injection of long-acting naltrexone in prison followed by 6 monthly injections post-release at the patient's place of residence utilizing mobile medical treatment. The primary outcomes are: treatment adherence; opioid use; criminal activity; re-arrest; reincarceration; and HIV risk-behaviors. Results We describe the background and rationale for the study, its aims, hypotheses, and study design. Conclusions The use of long-acting injectable naltrexone may be a promising form of treatment for pre-release prisoners. Finally, as many individuals in the criminal justice system drop out of treatment, this study will assess whether treatment at their place of residence will improve adherence and positively affect treatment outcomes. PMID:28011389

  17. Extended-release naltrexone for pre-release prisoners: A randomized trial of medical mobile treatment.

    Science.gov (United States)

    Gordon, Michael S; Vocci, Frank J; Fitzgerald, Terrence T; O'Grady, Kevin E; O'Brien, Charles P

    2017-02-01

    Extended-release naltrexone (XR-NTX), is an effective treatment for opioid use disorder but is rarely initiated in US prisons or with criminal justice populations. Mobile treatment for chronic diseases has been implemented in a variety of settings. Mobile treatment may provide an opportunity to expand outreach to parolees to surmount barriers to traditional clinic treatment. Male and female prisoners (240) with pre-incarceration histories of opioid use disorder who are within one month of release from prison will be enrolled in this randomized clinical trial. Participants are randomized to one of two study arms: 1) [XR-NTX-OTx] One injection of long-acting naltrexone in prison, followed by 6 monthly injections post-release at a community opioid treatment program; or 2) [XR-NTX+ MMTx] One injection of long-acting naltrexone in prison followed by 6 monthly injections post-release at the patient's place of residence utilizing mobile medical treatment. The primary outcomes are: treatment adherence; opioid use; criminal activity; re-arrest; reincarceration; and HIV risk-behaviors. We describe the background and rationale for the study, its aims, hypotheses, and study design. The use of long-acting injectable naltrexone may be a promising form of treatment for pre-release prisoners. Finally, as many individuals in the criminal justice system drop out of treatment, this study will assess whether treatment at their place of residence will improve adherence and positively affect treatment outcomes. ClinicalTrials.gov: NCT02867124. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-01-17

    Dexamethasone loaded poly(lactic-co-glycolic acid) (PLGA) microsphere/PVA hydrogel composites have been investigated as an outer drug-eluting coating for implantable devices such as glucose sensors to counter negative tissue responses to implants. The objective of this study was to develop a discriminatory, accelerated in vitro release testing method for this drug-eluting coating using United States Pharmacopeia (USP) apparatus 4. Polymer degradation and drug release kinetics were investigated under "real-time" and accelerated conditions (i.e. extreme pH, hydro-alcoholic solutions and elevated temperatures). Compared to "real-time" conditions, the initial burst and lag phases were similar using hydro-alcoholic solutions and extreme pH conditions, while the secondary apparent zero-order release phase was slightly accelerated. Elevated temperatures resulted in a significant acceleration of dexamethasone release. The accelerated release data were able to predict "real-time" release when applying the Arrhenius equation. Microsphere batches with faster and slower release profiles were investigated under "real-time" and elevated temperature (60°C) conditions to determine the discriminatory ability of the method. The results demonstrated both the feasibility and the discriminatory ability of this USP apparatus 4 method for in vitro release testing of drug loaded PLGA microsphere/PVA hydrogel composites. This method may be appropriate for similar drug/device combination products and drug delivery systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Perception of CPR quality: Influence of CPR feedback, Just-in-Time CPR training and provider role.

    Science.gov (United States)

    Cheng, Adam; Overly, Frank; Kessler, David; Nadkarni, Vinay M; Lin, Yiqun; Doan, Quynh; Duff, Jonathan P; Tofil, Nancy M; Bhanji, Farhan; Adler, Mark; Charnovich, Alex; Hunt, Elizabeth A; Brown, Linda L

    2015-02-01

    Many healthcare providers rely on visual perception to guide cardiopulmonary resuscitation (CPR), but little is known about the accuracy of provider perceptions of CPR quality. We aimed to describe the difference between perceived versus measured CPR quality, and to determine the impact of provider role, real-time visual CPR feedback and Just-in-Time (JIT) CPR training on provider perceptions. We conducted secondary analyses of data collected from a prospective, multicenter, randomized trial of 324 healthcare providers who participated in a simulated cardiac arrest scenario between July 2012 and April 2014. Participants were randomized to one of four permutations of: JIT CPR training and real-time visual CPR feedback. We calculated the difference between perceived and measured quality of CPR and reported the proportion of subjects accurately estimating the quality of CPR within each study arm. Participants overestimated achieving adequate chest compression depth (mean difference range: 16.1-60.6%) and rate (range: 0.2-51%), and underestimated chest compression fraction (0.2-2.9%) across all arms. Compared to no intervention, the use of real-time feedback and JIT CPR training (alone or in combination) improved perception of depth (pCPR quality was poor for chest compression depth (0-13%), rate (5-46%) and chest compression fraction (60-63%). Perception of depth is more accurate in CPR providers versus team leaders (27.8% vs. 7.4%; p=0.043) when using real-time feedback. Healthcare providers' visual perception of CPR quality is poor. Perceptions of CPR depth are improved by using real-time visual feedback and with prior JIT CPR training. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Myocardial myoglobin release after acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, P S; Saltissi, S; Coltart, D J; Croft, D N [Saint Thomas' Hospital, London (UK)

    1980-03-01

    The magnitude and time course of myoglobin release from the myocardium following infarction was assessed by radioimmunoassay. The assay showed acceptable precision over a working range from 50 to 750 ng cm/sup -3/, provided careful control of the assay temperature was maintained. The use of this radioimmunoassay as an early diagnostic test for infarction and as a potential measure of the extent of necrosis is considered and comparison made with the release of CK-MB, the myocardial specific isoenzyme of creatine kinase. Of the twenty patients studied with myocardial infarction, all had elevated levels of serum myoglobin including those admitted within 3 hours of the onset of pain. In contrast, CK-MB was not detected in the serum within 5 hours of the onset of pain. Peak serum levels of myoglobin (mean 852 +- 365 ng cm/sup -3/) and CK-MB (mean 71 +- 25 mIU cm/sup -3/) were detected at 8-16 hours and 20-24 hours respectively after the onset of pain. A comparison of peak serum levels of myoglobin and CK-MB showed a good correlation (r = 0.84).

  1. Scaling up ATLAS Database Release Technology for the LHC Long Run

    International Nuclear Information System (INIS)

    Borodin, M; Nevski, P; Vaniachine, A

    2011-01-01

    To overcome scalability limitations in database access on the Grid, ATLAS introduced the Database Release technology replicating databases in files. For years Database Release technology assured scalable database access for Monte Carlo production on the Grid. Since previous CHEP, Database Release technology was used successfully in ATLAS data reprocessing on the Grid. Frozen Conditions DB snapshot guarantees reproducibility and transactional consistency isolating Grid data processing tasks from continuous conditions updates at the 'live' Oracle server. Database Release technology fully satisfies the requirements of ATLAS data reprocessing and Monte Carlo production. We parallelized the Database Release build workflow to avoid linear dependency of the build time on the length of LHC data-taking period. In recent data reprocessing campaigns the build time was reduced by an order of magnitude thanks to a proven master-worker architecture used in the Google MapReduce. We describe further Database Release optimizations scaling up the technology for the LHC long run.

  2. Experimental study of PLLA/INH slow release implant fabricated by three dimensional printing technique and drug release characteristics in vitro.

    Science.gov (United States)

    Wu, Gui; Wu, Weigang; Zheng, Qixin; Li, Jingfeng; Zhou, Jianbo; Hu, Zhilei

    2014-07-19

    Local slow release implant provided long term and stable drug release in the lesion. The objective of this study was to fabricate biodegradable slow release INH/PLLA tablet via 3 dimensional printing technique (3DP) and to compare the drug release characteristics of three different structured tablets in vitro. Three different drug delivery systems (columnar-shaped tablet (CST), doughnut-shaped tablet (DST) and multilayer doughnut-shaped tablet (MDST)) were manufactured by the three dimensional printing machine and isoniazid was loaded into the implant. Dynamic soaking method was used to study the drug release characteristics of the three implants. MTT cytotoxicity test and direct contact test were utilized to study the biocompatibility of the implant. The microstructures of the implants' surfaces were observed with electron microscope. The PLLA powder in the tablet could be excellently combined through 3DP without disintegration. Electron microscope observations showed that INH distributed evenly on the surface of the tablet in a "nest-shaped" way, while the surface of the barrier layer in the multilayer doughnut shaped tablet was compact and did not contain INH. The concentration of INH in all of the three tablets were still higher than the effective bacteriostasis concentration (Isoniazid: 0.025 ~ 0.05 μg/ml) after 30 day's release in vitro. All of the tablets showed initial burst release of the INH in the early period. Drug concentration of MDST became stable and had little fluctuation starting from the 6th day of the release. Drug concentration of DST and CST decreased gradually and the rate of decrease in concentration was faster in DST than CST. MTT cytotoxicity test and direct contact test indicated that the INH-PLLA tablet had low cytotoxicity and favorable biocompatibility. Three dimensional printing technique was a reliable technique to fabricate complicated implants. Drug release pattern in MDST was the most stable among the three implants. It was

  3. Development and Validation of a National System for Routine Monitoring of Mortality in People Recently Released from Prison.

    Directory of Open Access Journals (Sweden)

    Stuart A Kinner

    Full Text Available People released from prison are at increased risk of death. However, no country has established a system for routine monitoring of mortality in this population. The aims of this study were to (a evaluate a system for routine monitoring of deaths after release from prison in Australia and (b estimate the number of deaths annually within 28 and 365 days of prison release from 2000 to 2013.Persons released from prison and deaths were identified in records held by Centrelink, Australia's national provider of unemployment benefits. Estimates generated in this manner were compared with those from a study that probabilistically linked correctional records with the National Death Index (NDI, for each calendar year 2000 to 2007. Using Centrelink data, national estimates of mortality within 28 and 365 days of release were produced for each calendar year 2000 to 2013.Compared with estimates based on linkage with the NDI, the estimated crude mortality rate based on Centrelink records was on average 52% lower for deaths within 28 days of release and 24% lower for deaths within 365 days of release. Nationally, over the period 2000 to 2013, we identified an average of 32 deaths per year within 28 days of release and 188 deaths per year within 365 days of release. The crude mortality rate for deaths within both 28 and 365 days of release increased over this time.Using routinely collected unemployment benefits data we detected the majority of deaths in people recently released from prison in Australia. These data may be sufficient for routine monitoring purposes and it may be possible to adopt a similar approach in other countries. Routine surveillance of mortality in ex-prisoners serves to highlight their extreme vulnerability and provides a basis for evaluating policy reforms designed to reduce preventable deaths.

  4. Comparative study of some mechanical and release properties of ...

    African Journals Online (AJOL)

    The mechanical and release properties of paracetamol tablets formulated with cashew gum (CAG), povidone (PVP) and gelatin (GEL) as binders were studied and compared. The parameters studied were tensile strength (TS), brittle fracture index (BFI), friability (F), disintegration time (DT) and percentage drug released ...

  5. Polymeric nanoparticles containing diazepam: preparation, optimization, characterization, in-vitro drug release and release kinetic study

    Science.gov (United States)

    Bohrey, Sarvesh; Chourasiya, Vibha; Pandey, Archna

    2016-03-01

    Nanoparticles formulated from biodegradable polymers like poly(lactic-co-glycolic acid) (PLGA) are being extensively investigated as drug delivery systems due to their two important properties such as biocompatibility and controlled drug release characteristics. The aim of this work to formulated diazepam loaded PLGA nanoparticles by using emulsion solvent evaporation technique. Polyvinyl alcohol (PVA) is used as stabilizing agent. Diazepam is a benzodiazepine derivative drug, and widely used as an anticonvulsant in the treatment of various types of epilepsy, insomnia and anxiety. This work investigates the effects of some preparation variables on the size and shape of nanoparticles prepared by emulsion solvent evaporation method. These nanoparticles were characterized by photon correlation spectroscopy (PCS), transmission electron microscopy (TEM). Zeta potential study was also performed to understand the surface charge of nanoparticles. The drug release from drug loaded nanoparticles was studied by dialysis bag method and the in vitro drug release data was also studied by various kinetic models. The results show that sonication time, polymer content, surfactant concentration, ratio of organic to aqueous phase volume, and the amount of drug have an important effect on the size of nanoparticles. Hopefully we produced spherical shape Diazepam loaded PLGA nanoparticles with a size range under 250 nm with zeta potential -23.3 mV. The in vitro drug release analysis shows sustained release of drug from nanoparticles and follow Korsmeyer-Peppas model.

  6. Dual-controlled release system of drugs for bone regeneration.

    Science.gov (United States)

    Kim, Yang-Hee; Tabata, Yasuhiko

    2015-11-01

    Controlled release systems have been noted to allow drugs to enhance their ability for bone regeneration. To this end, various biomaterials have been used as the release carriers of drugs, such as low-molecular-weight drugs, growth factors, and others. The drugs are released from the release carriers in a controlled fashion to maintain their actions for a long time period. Most research has been focused on the controlled release of single drugs to demonstrate the therapeutic feasibility. Controlled release of two combined drugs, so-called dual release systems, are promising and important for tissue regeneration. This is because the tissue regeneration process of bone formation is generally achieved by multiple bioactive molecules, which are produced from cells by other molecules. If two types of bioactive molecules, (i.e., drugs), are supplied in an appropriate fashion, the regeneration process of living bodies will be efficiently promoted. This review focuses on the bone regeneration induced by dual-controlled release of drugs. In this paper, various dual-controlled release systems of drugs aiming at bone regeneration are overviewed explaining the type of drugs and their release materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. PAVAN: an atmospheric-dispersion program for evaluating design-basis accidental releases of radioactive materials from nuclear power stations

    International Nuclear Information System (INIS)

    Bander, T.J.

    1982-11-01

    This report provides a user's guide for the NRC computer program, PAVAN, which is a program used by the US Nuclear Regulatory Commission to estimate downwind ground-level air concentrations for potential accidental releases of radioactive material from nuclear facilities. Such an assessment is required by 10 CFR Part 100 and 10 CFR Part 50. The program implements the guidance provided in Regulatory Guide 1.145, Atmospheric Dispersion Models for Potential Accident Consequence Assessments at Nuclear Power Plants. Using joint frequency distributions of wind direction and wind speed by atmospheric stability, the program provides relative air concentration (X/Q) values as functions of direction for various time periods at the exclusion area boundary (EAB) and the outer boundary of the low population zone (LPZ). Calculations of X/Q values can be made for assumed ground-level releases (e.g., through building penetrations and vents) or elevated releases from free-standing stacks. Various options may be selected by the user. They can account for variation in the location of release points, additional plume dispersion due to building wakes, plume meander under low wind speed conditions, and adjustments to consider non-straight trajectories. It computes an effective plume height using the physical release height which can be reduced by inputted terrain features. It cannot handle multiple emission sources. A description of the main program and all subroutines is provided. Also included as appendices are a complete listing of the program and two test cases with the required data inputs and the resulting program outputs

  8. Stereoselectivity of presynaptic autoreceptors modulating dopamine release

    International Nuclear Information System (INIS)

    Arbilla, S.; Langer, S.Z.

    1981-01-01

    The effects of the (R)- and (S)-enantiomers of sulpiride and butaclamol were studied on the spontaneous and field stimulation-evoked release of total radioactivity from slices of rabbit caudate nucleus prelabelled with [ 3 H]dopamine. (S)-Sulpiride in concentrations ranging from 0.01-1μM enhanced the electrically evoked release of [ 3 H]dopamine while (R)-sulpiride was 10 times less potent than (S)-sulpiride. Exposure to (S)-butaclamol (0.1-1 μM) but not to (R)-butaclamol (0.1-10μM) enhanced the field-stimulated release of [ 3 H]dopamine. The facilitatory effects of (S)- and (R)-sulpiride and (S)-butaclamol on the stimulated release of the labelled neurotransmitter were observed under conditions in which these drugs did not modify the spontaneous outflow of radioactivity. Only the active enantiomers of sulpiride and butaclamol antagonized the inhibition by apomorphine (1μM) of the stimulated release of [ 3 H]dopamine. Our results indicate that the presynaptic inhibitory dopamine autoreceptors modulating the stimulation-evoked release of [ 3 H]dopamine in the caudate nucleus are, like the classical postsynaptic dopamine receptors, chemically stereoselective. (Auth.)

  9. Effect of Latent Heat Released by Freezing Droplets during Frost Wave Propagation.

    Science.gov (United States)

    Chavan, Shreyas; Park, Deokgeun; Singla, Nitish; Sokalski, Peter; Boyina, Kalyan; Miljkovic, Nenad

    2018-05-21

    Frost spreads on nonwetting surfaces during condensation frosting via an interdroplet frost wave. When a supercooled condensate water droplet freezes on a hydrophobic or superhydrophobic surface, neighboring droplets still in the liquid phase begin to evaporate. Two possible mechanisms govern the evaporation of neighboring water droplets: (1) The difference in saturation pressure of the water vapor surrounding the liquid and frozen droplets induces a vapor pressure gradient, and (2) the latent heat released by freezing droplets locally heats the substrate, leading to evaporation of nearby droplets. The relative significance of these two mechanisms is still not understood. Here, we study the significance of the latent heat released into the substrate by freezing droplets, and its effect on adjacent droplet evaporation, by studying the dynamics of individual water droplet freezing on aluminum-, copper-, and glass-based hydrophobic and superhydrophobic surfaces. The latent heat flux released into the substrate was calculated from the measured droplet sizes and the respective freezing times ( t f ), defined as the time from initial ice nucleation within the droplet to complete droplet freezing. To probe the effect of latent heat release, we performed three-dimensional transient finite element simulations showing that the transfer of latent heat to neighboring droplets is insignificant and accounts for a negligible fraction of evaporation during microscale frost wave propagation. Furthermore, we studied the effect of substrate thermal conductivity on the transfer of latent heat transfer to neighboring droplets by investigating the velocity of ice bridge formation. The velocity of the ice bridge was independent of the substrate thermal conductivity, indicating that adjacent droplet evaporation during condensation frosting is governed solely by vapor pressure gradients. This study not only provides key insights into the individual droplet freezing process but also

  10. Transcriptome of extracellular vesicles released by hepatocytes.

    Directory of Open Access Journals (Sweden)

    Felix Royo

    Full Text Available The discovery that the cells communicate through emission of vesicles has opened new opportunities for better understanding of physiological and pathological mechanisms. This discovery also provides a novel source for non-invasive disease biomarker research. Our group has previously reported that hepatocytes release extracellular vesicles with protein content reflecting the cell-type of origin. Here, we show that the extracellular vesicles released by hepatocytes also carry RNA. We report the messenger RNA composition of extracellular vesicles released in two non-tumoral hepatic models: primary culture of rat hepatocytes and a progenitor cell line obtained from a mouse foetal liver. We describe different subpopulations of extracellular vesicles with different densities and protein and RNA content. We also show that the RNA cargo of extracellular vesicles released by primary hepatocytes can be transferred to rat liver stellate-like cells and promote their activation. Finally, we provide in vitro and in vivo evidence that liver-damaging drugs galactosamine, acetaminophen, and diclofenac modify the RNA content of these vesicles. To summarize, we show that the extracellular vesicles secreted by hepatocytes contain various RNAs. These vesicles, likely to be involved in the activation of stellate cells, might become a new source for non-invasive identification of the liver toxicity markers.

  11. A prominent anchoring effect on the kinetic control of drug release from mesoporous silica nanoparticles (MSNs).

    Science.gov (United States)

    Tran, Vy Anh; Lee, Sang-Wha

    2018-01-15

    This work demonstrated kinetically controlled release of model drugs (ibuprofen, FITC) from well-tailored mesoporous silica nanoparticles (MSNs) depending on the surface charges and molecular sizes of the drugs. The molecular interactions between entrapped drugs and the pore walls of MSNs controlled the release of the drugs through the pore channels of MSNs. Also, polydopamine (PDA) layer-coated MSNs (MSNs@PDA) was quite effective to retard the release of large FITC, in contrast to a slight retardation effect on relatively small Ibuprofen. Of all things, FITC (Fluorescein isothiocyanate)-labeled APTMS (3-aminopropyltrimethoxysilane) (APTMS-FITC conjugates) grafted onto the MSNs generate a pinch-effect on the pore channel (so-called a prominent anchoring effect), which was highly effective in trapping (or blocking) drug molecules at the pore mouth of the MSNs. The anchored APTMS-FITC conjugates provided not only tortuous pathways to the diffusing molecules, but also sustained release of the ibuprofen over a long period of time (∼7days). The fast release kinetics was predicted by an exponential equation based on Fick's law, while the slow release kinetics was predicted by Higuchi model. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Iodine-131 releases from the Hanford Site, 1944--1947

    International Nuclear Information System (INIS)

    Heeb, C.M.

    1992-10-01

    Detailed results of the Hanford Environmental Dose Reconstruction (HEDR) iodine-131 release reconstruction are presented in this volume. Included are daily data on B, D, and F Plant, reactor operations from the P-Department Daily Reports (General Electric Company 1947). Tables of B and T Plant material processed from the three principal sources on separations plant operations: The Jaech report (Jaech undated), the 200 Area Report (Acken and Bird 1945; Bird and Donihee 1945), and the Metal History Reports (General Electric Company 1946). A transcription of the Jaech report is also provided because it is computer-generated and is not readily readable in its original format. The iodine-131 release data are from the STRM model. Cut-by-cut release estimates are provided, along with daily, monthly, and yearly summations. These summations are based on the hourly release estimates. The hourly data are contained in a 28 megabyte electronic file. Interested individuals may request a copy

  13. Extended‐Release Once‐Daily Formulation of Tofacitinib: Evaluation of Pharmacokinetics Compared With Immediate‐Release Tofacitinib and Impact of Food

    Science.gov (United States)

    Wang, Rong; Fletcher, Tracey; Alvey, Christine; Kushner, Joseph; Stock, Thomas C.

    2016-01-01

    Abstract Tofacitinib is an oral Janus kinase inhibitor for the treatment of rheumatoid arthritis. An extended‐release (XR) formulation has been designed to provide a once‐daily (QD) dosing option to patients to achieve comparable pharmacokinetic (PK) parameters to the twice‐daily immediate‐release (IR) formulation. We conducted 2 randomized, open‐label, phase 1 studies in healthy volunteers. Study A characterized single‐dose and steady‐state PK of tofacitinib XR 11 mg QD and intended to demonstrate equivalence of exposure under single‐dose and steady‐state conditions to tofacitinib IR 5 mg twice daily. Study B assessed the effect of a high‐fat meal on the bioavailability of tofacitinib from the XR formulation. Safety and tolerability were monitored in both studies. In study A (N = 24), the XR and IR formulations achieved time to maximum plasma concentration at 4 hours and 0.5 hours postdose, respectively; terminal half‐life was 5.9 hours and 3.2 hours, respectively. Area under plasma concentration‐time curve (AUC) and maximum plasma concentration (Cmax) after single‐ and multiple‐dose administration were equivalent between the XR and IR formulations. In study B (N = 24), no difference in AUC was observed for fed vs fasted conditions. Cmax increased by 27% under the fed state. On repeat administration, negligible accumulation (Tofacitinib administration as an XR or IR formulation was generally well tolerated in these studies. PMID:26970526

  14. Dry release of suspended nanostructures

    DEFF Research Database (Denmark)

    Forsén, Esko Sebastian; Davis, Zachary James; Dong, M.

    2004-01-01

    , the technique enables long time storage and transportation of produced devices without the risk of stiction. By combining the dry release method with a plasma deposited anti-stiction coating both fabrication induced stiction, which is mainly caused by capillary forces originating from the dehydration...

  15. Tech-X Corporation releases simulation code for solving complex problems in plasma physics : VORPAL code provides a robust environment for simulating plasma processes in high-energy physics, IC fabrications and material processing applications

    CERN Multimedia

    2005-01-01

    Tech-X Corporation releases simulation code for solving complex problems in plasma physics : VORPAL code provides a robust environment for simulating plasma processes in high-energy physics, IC fabrications and material processing applications

  16. Protocol for development of authorized release limits for concrete at U.S. Department of Energy sites

    International Nuclear Information System (INIS)

    Arnish, J.; Kamboj, S.; Chen, S.-Y.; Parker, F. L.; Smith, A. M.; Meservey, R. H.; Tripp, J. L.

    2000-01-01

    The purpose of this protocol is to assist US Department of Energy (DOE) sites in releasing concrete for reuse. Current regulations allow the sites to release surface-contaminated materials if their radioactivity falls below certain levels and to possibly release materials with volumetric contamination or higher levels of surface contamination on a case-by-case basis. In all cases, an ALARA (as low as reasonably achievable) analysis that evaluates the risks of releasing volumetrically contaminated concrete or concrete with higher levels of surface contamination is required as a basis for proposing and setting new release limits that allow for reuse of the concrete material. To evaluate the dose impacts of reusing radioactively contaminated material, the measured radiation levels (pCi/g or disintegrations per minute [dpm]/100 cm 2 ) must be converted to the estimated dose (mrem/yr) that would be received by affected individuals. The dose depends on the amounts and types of isotopes present and the time, distance, and method of exposure (e.g., inhalation or external exposure). For each disposition alternative, the protocol provides a systematic method to evaluate the impact of the dose on the affected individuals. The cost impacts of reusing concrete also need to be evaluated. They too depend on the disposition alternative and the extent and type of contamination. The protocol provides a method to perform a detailed analysis of these factors and evaluate the dose and cost impacts for various disposition alternatives. Once the dose and cost impacts of the various alternatives have been estimated, the protocol outlines the steps required to propose new release standards that allow release and reuse of the concrete material

  17. 7 CFR 2902.36 - Concrete and asphalt release fluids.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Concrete and asphalt release fluids. 2902.36 Section... PROCUREMENT Designated Items § 2902.36 Concrete and asphalt release fluids. (a) Definition. Products that are designed to provide a lubricating barrier between the composite surface materials (e.g., concrete or...

  18. Sparse Bayesian learning machine for real-time management of reservoir releases

    Science.gov (United States)

    Khalil, Abedalrazq; McKee, Mac; Kemblowski, Mariush; Asefa, Tirusew

    2005-11-01

    Water scarcity and uncertainties in forecasting future water availabilities present serious problems for basin-scale water management. These problems create a need for intelligent prediction models that learn and adapt to their environment in order to provide water managers with decision-relevant information related to the operation of river systems. This manuscript presents examples of state-of-the-art techniques for forecasting that combine excellent generalization properties and sparse representation within a Bayesian paradigm. The techniques are demonstrated as decision tools to enhance real-time water management. A relevance vector machine, which is a probabilistic model, has been used in an online fashion to provide confident forecasts given knowledge of some state and exogenous conditions. In practical applications, online algorithms should recognize changes in the input space and account for drift in system behavior. Support vectors machines lend themselves particularly well to the detection of drift and hence to the initiation of adaptation in response to a recognized shift in system structure. The resulting model will normally have a structure and parameterization that suits the information content of the available data. The utility and practicality of this proposed approach have been demonstrated with an application in a real case study involving real-time operation of a reservoir in a river basin in southern Utah.

  19. Hypoxic enhancement of exosome release by breast cancer cells

    International Nuclear Information System (INIS)

    King, Hamish W; Michael, Michael Z; Gleadle, Jonathan M

    2012-01-01

    Exosomes are nanovesicles secreted by tumour cells which have roles in paracrine signalling during tumour progression, including tumour-stromal interactions, activation of proliferative pathways and bestowing immunosuppression. Hypoxia is an important feature of solid tumours which promotes tumour progression, angiogenesis and metastasis, potentially through exosome-mediated signalling. Breast cancer cell lines were cultured under either moderate (1% O 2 ) or severe (0.1% O 2 ) hypoxia. Exosomes were isolated from conditioned media and quantitated by nanoparticle tracking analysis (NTA) and immunoblotting for the exosomal protein CD63 in order to assess the impact of hypoxia on exosome release. Hypoxic exosome fractions were assayed for miR-210 by real-time reverse transcription polymerase chain reaction and normalised to exogenous and endogenous control genes. Statistical significance was determined using the Student T test with a P value of < 0.05 considered significant. Exposure of three different breast cancer cell lines to moderate (1% O 2 ) and severe (0.1% O 2 ) hypoxia resulted in significant increases in the number of exosomes present in the conditioned media as determined by NTA and CD63 immunoblotting. Activation of hypoxic signalling by dimethyloxalylglycine, a hypoxia-inducible factor (HIF) hydroxylase inhibitor, resulted in significant increase in exosome release. Transfection of cells with HIF-1α siRNA prior to hypoxic exposure prevented the enhancement of exosome release by hypoxia. The hypoxically regulated miR-210 was identified to be present at elevated levels in hypoxic exosome fractions. These data provide evidence that hypoxia promotes the release of exosomes by breast cancer cells, and that this hypoxic response may be mediated by HIF-1α. Given an emerging role for tumour cell-derived exosomes in tumour progression, this has significant implications for understanding the hypoxic tumour phenotype, whereby hypoxic cancer cells may release

  20. Sustained-release progesterone vaginal suppositories 1--development of sustained-release granule--.

    Science.gov (United States)

    Nakayama, Ayako; Sunada, Hisakazu; Okamoto, Hirokazu; Furuhashi, Kaoru; Ohno, Yukiko; Ito, Mikio

    2009-02-01

    Progesterone (P) is an important hormone for the establishment of pregnancy, and its administration is useful for luteal insufficiency. Considering the problems of commercially available oral and injection drugs, hospital-formulated vaginal suppositories are clinically used. However, since the half-life of P suppositories is short, it is difficult to maintain its constant blood concentration. To sustain drug efficacy and prevent side-effects, we are attempting to develop sustained-release suppositories by examining the degree of sustained-release of active ingredients. In this study, we examined the combinations of granulation methods and release systems for the preparation of sustained-release granules of P, and produced 13 types of sustained-release granules. We also examined the diameter, content, and dissolution of each type of granules, and confirmed that the sustained-release of all types of granules was satisfactory. Among the sustained-release granules, we selected granules with a content and a degree of sustained-release suitable for sustained-release suppositories.

  1. Evaluation of hydrophobic materials as matrices for controlled-release drug delivery.

    Science.gov (United States)

    Quadir, Mohiuddin Abdul; Rahman, M Sharifur; Karim, M Ziaul; Akter, Sanjida; Awkat, M Talat Bin; Reza, Md Selim

    2003-07-01

    The present study was undertaken to evaluate the effect of different insoluble and erodable wax-lipid based materials and their content level on the release profile of drug from matrix systems. Matrix tablets of theophylline were prepared using carnauba wax, bees wax, stearic acid, cetyl alcohol, cetostearyl alcohol and glyceryl monostearate as rate-retarding agents by direct compression process. The release of theophylline from these hydrophobic matrices was studied over 8-hours in buffer media of pH 6.8. Statistically significant difference was found among the drug release profile from different matrices. The release kinetics was found to be governed by the type and content of hydrophobic materials in the matrix. At lower level of wax matrices (25%), a potential burst release was observed with all the materials being studied. Bees wax could not exert any sustaining action while an extensive burst release was found with carnauba wax at this hydrophobic load. Increasing the concentration of fat-wax materials significantly decreased the burst effect of drug from the matrix. At higher hydrophobic level (50% of the matrix), the rate and extent of drug release was significantly reduced due to increased tortuosity and reduced porosity of the matrix. Cetostearyl alcohol imparted the strongest retardation of drug release irrespective of fat-wax level. Numerical fits indicate that the Higuchi square root of time model was the most appropriate one for describing the release profile of theophylline from hydrophobic matrices. The release mechanism was also explored and explained with biexponential equation. Application of this model indicates that Fickian or case I kinetics is the predominant mechanism of drug release from these wax-lipid matrices. The mean dissolution time (MDT) was calculated for all the formulations and the highest MDT value was obtained with cetostearyl matrix. The greater sustaining activity of cetostearyl alcohol can be attributed to some level of

  2. Mathematical modeling of drug release from lipid dosage forms.

    Science.gov (United States)

    Siepmann, J; Siepmann, F

    2011-10-10

    Lipid dosage forms provide an interesting potential for controlled drug delivery. In contrast to frequently used poly(ester) based devices for parenteral administration, they do not lead to acidification upon degradation and potential drug inactivation, especially in the case of protein drugs and other acid-labile active agents. The aim of this article is to give an overview on the current state of the art of mathematical modeling of drug release from this type of advanced drug delivery systems. Empirical and semi-empirical models are described as well as mechanistic theories, considering diffusional mass transport, potentially limited drug solubility and the leaching of other, water-soluble excipients into the surrounding bulk fluid. Various practical examples are given, including lipid microparticles, beads and implants, which can successfully be used to control the release of an incorporated drug during periods ranging from a few hours up to several years. The great benefit of mechanistic mathematical theories is the possibility to quantitatively predict the effects of different formulation parameters and device dimensions on the resulting drug release kinetics. Thus, in silico simulations can significantly speed up product optimization. This is particularly useful if long release periods (e.g., several months) are targeted, since experimental trial-and-error studies are highly time-consuming in these cases. In the future it would be highly desirable to combine mechanistic theories with the quantitative description of the drug fate in vivo, ideally including the pharmacodynamic efficacy of the treatments. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Statistical sampling method for releasing decontaminated vehicles

    International Nuclear Information System (INIS)

    Lively, J.W.; Ware, J.A.

    1996-01-01

    Earth moving vehicles (e.g., dump trucks, belly dumps) commonly haul radiologically contaminated materials from a site being remediated to a disposal site. Traditionally, each vehicle must be surveyed before being released. The logistical difficulties of implementing the traditional approach on a large scale demand that an alternative be devised. A statistical method (MIL-STD-105E, open-quotes Sampling Procedures and Tables for Inspection by Attributesclose quotes) for assessing product quality from a continuous process was adapted to the vehicle decontamination process. This method produced a sampling scheme that automatically compensates and accommodates fluctuating batch sizes and changing conditions without the need to modify or rectify the sampling scheme in the field. Vehicles are randomly selected (sampled) upon completion of the decontamination process to be surveyed for residual radioactive surface contamination. The frequency of sampling is based on the expected number of vehicles passing through the decontamination process in a given period and the confidence level desired. This process has been successfully used for 1 year at the former uranium mill site in Monticello, Utah (a CERCLA regulated clean-up site). The method forces improvement in the quality of the decontamination process and results in a lower likelihood that vehicles exceeding the surface contamination standards are offered for survey. Implementation of this statistical sampling method on Monticello Projects has resulted in more efficient processing of vehicles through decontamination and radiological release, saved hundreds of hours of processing time, provided a high level of confidence that release limits are met, and improved the radiological cleanliness of vehicles leaving the controlled site

  4. A comparison of the extended-release and standard-release formulations of tacrolimus in de novo kidney transplant recipients: a 12-month outcome study.

    Science.gov (United States)

    Fanous, Helen; Zheng, Rebecca; Campbell, Carolyn; Huang, Michael; Nash, Michelle M; Rapi, Lindita; Zaltzman, Jeffrey S; Prasad, G V Ramesh

    2013-02-01

    BACKGROUND: Limited comparative data are available on the outcomes between extended-release and standard-release tacrolimus when used de novo in kidney transplant recipients (KTRs). METHODS: We identified KTRs transplanted at our institution during 2009-10 routinely prescribed extended-release tacrolimus and compared them with those transplanted during 2008-09 prescribed standard-release tacrolimus. Graft function (eGFR by MDRD-7 equation) at 12 months post-transplant (primary outcome); new-onset diabetes and other cardiovascular risk factors, BK viremia incidence, acute rejection, and graft survival to 12 months (secondary outcomes) were compared by intent-to-treat analysis. Time-to-steady-state concentration and number of dose adjustments required to attain steady state were recorded. RESULTS: There were no important demographic differences between the extended-release (N = 106) and standard-release (N = 95) cohorts. The estimated glomerular filtration rate (eGFR) at 12 months was similar (58.8 ± 17 versus 59.2 ± 18 mL/min/1.73 m(2), P = 0.307). There was no difference in new-onset diabetes (17 versus 20%, P = 0.581), BK viremia (10 versus 7%, P = 0.450), acute rejection (7 versus 16%, P = 0.067) or graft survival (97 versus 95%, P = 0.301). Time-to-steady state was similar (9.2 ± 1.1 versus 8.1 ± 4.7 days, P = 0.490) although extended-release patients required fewer adjustments to attain steady state (1.2 ± 1.7 [0-8] versus 1.7 ± 1.5 [0-7], P = 0.030) but a similar dose (7.2 ± 2.4 [2-17] versus 7 ± 2.7 [2-16] mg/day, P = 0.697). CONCLUSION: De novo KTRs prescribed extended-release or standard-release tacrolimus demonstrate similar 12-month outcomes.

  5. Comparison of the release of constituents from granular materials under batch and column testing.

    Science.gov (United States)

    Lopez Meza, Sarynna; Garrabrants, Andrew C; van der Sloot, Hans; Kosson, David S

    2008-01-01

    Column leaching testing can be considered a better basis for assessing field impact data than any other available batch test method and thus provides a fundamental basis from which to estimate constituent release under a variety of field conditions. However, column testing is time-intensive compared to the more simplified batch testing, and may not always be a viable option when making decisions for material reuse. Batch tests are used most frequently as a simple tool for compliance or quality control reasons. Therefore, it is important to compare the release that occurs under batch and column testing, and establish conservative interpretation protocols for extrapolation from batch data when column data are not available. Five different materials (concrete, construction debris, aluminum recycling residue, coal fly ash and bottom ash) were evaluated via batch and column testing, including different column flow regimes (continuously saturated and intermittent unsaturated flow). Constituent release data from batch and column tests were compared. Results showed no significant difference between the column flow regimes when constituent release data from batch and column tests were compared. In most cases batch and column testing agreed when presented in the form of cumulative release. For arsenic in carbonated materials, however, batch testing underestimates the column constituent release for most LS ratios and also on a cumulative basis. For cases when As is a constituent of concern, column testing may be required.

  6. The Dark Energy Survey First Data Release

    Science.gov (United States)

    Carrasco Kind, Matias

    2018-01-01

    In this talk I will announce and highlight the main components of the first public data release (DR1) coming from the Dark Energy Survey (DES).In January 2016, the DES survey made available, in a simple unofficial release to the astronomical community, the first set of products. This data was taken and studied during the DES Science Verification period consisting on roughly 250 sq. degrees and 25 million objects at a mean depth of i=23.7 that led to over 80 publications from DES scientist.The DR1 release is the first official release from the main survey and it consists on the observations taken during the first 3 seasons from August 2013 to February 2016 (about 100 nights each season) of the survey which cover the entire DES footprint. All of the Single Epoch Images and the Year 3 Coadded images distributed in 10223 tiles are available for download in this release. The catalogs provide astrometry, photometry and basic classification for near 400M objects in roughly 5000 sq. degrees on the southern hemisphere with a approximate mean depth of i=23.3. Complementary footprint, masking and depth information is also available. All of the software used during the generation of these products are open sourced and have been made available through the Github DES Organization. Images, data and other sub products have been possible through the international and collaborative effort of all 25 institutions involved in DES and are available for exploration and download through the interfaces provided by a partnership between NCSA, NOAO and LIneA.

  7. Modelling flow phenomena in time dependent store release from transonic aircraft

    CSIR Research Space (South Africa)

    MacLucas, David A

    2014-07-01

    Full Text Available Center (AEDC) [3] at angle of attack α=0° and Mach number M = 0.95. In the carriage position the separation distance of the store from the pylon was 0.070 inches. Data corrections may be found in the original report. The test case was conducted at a...-generated store grid through a background grid attached to the wing. Grids are illustrated in Figure 2 below. Refinement zones were also generated for both the parent and the release corridor. These assist with increasing the grid resolution in these areas...

  8. Release model for black liquor droplet; Mustalipeaepisaran vapautumismalli

    Energy Technology Data Exchange (ETDEWEB)

    Saastamoinen, J. [VTT Energy, Espoo (Finland)

    1997-10-01

    The release of sodium, potassium, chlorine and sulphur from black liquor droplets during pyrolysis, combustion and gasification is studied by modelling work. A model for drying, pyrolysis and swelling of black liquor has been developed earlier. A submodel for the release of sulphur, which takes place at temperatures below 500 deg C has been incorporated to this model. A previous model for the combustion and gasification of char particles has been further developed to account for the effect of sodium, potassium and chlorine. A model for the release of these components as function of time has been developed. (orig.)

  9. Medicare Referring Provider (DMEPOS) Data CY2013

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Centers for Medicare and Medicaid Services (CMS) released a new dataset, the Referring Provider Durable Medical Equipment, Prosthetics, Orthotics and Supplies...

  10. Atmospheric Release Advisory Capability (ARAC)

    International Nuclear Information System (INIS)

    Dickerson, M.H.

    1975-01-01

    The chief purpose of ARAC data acquisition program is to provide site officials, who are responsible for ensuring maximum health protection for the endangered site personnel and public, with estimates of the effects of atmospheric releases of hazardous material as rapidly and accurately as possible. ARAC is in the initial stages of being implemented and is therefore susceptible to changes before it reaches its final form. However the concept of ARAC is fully developed and was successfully demonstrated during a feasibility study conducted in June 1974, as a joint effort between the Savannah River Laboratory (SRL) and Lawrence Livermore Laboratory (LLL). Additional tests between SRL and LLL are scheduled for December 1975. While the immediate goal is the application of ARAC to assist a limited number of ERDA sites, the system is designed with sufficient flexibility to permit expanding the service to a large number of sites. Success in ARAC application should provide nuclear facilities with a means to handle better the urgent questions concerning the potential accidental hazards from atmospheric releases in addition to providing the sites with a capability to assess the effort of their normal operations

  11. Taking inventory on VOC releases from Amoco's Yorktown refinery

    International Nuclear Information System (INIS)

    Klee, H.H. Jr.; Schmitt, R.E.; Harrass, M.C.; Podar, M.K.

    1996-01-01

    Amoco's Yorktown, Virginia, refinery is a 35-year-old, 53,000 bbl/day facility that manufacturers gasoline, heating oil, liquid petroleum gas, sulfur, and coke. In a cooperative and voluntary effort, Amoco Corporation and the US Environmental Protection Agency conducted a joint project to study pollution prevention opportunities at an operating industrial facility. Source reduction efforts--key to pollution prevention strategies--require knowledge of specific sources of releases. However, data on releases from individual process units are limited in favor of data to monitor existing end-of-pipe pollution control requirements. The study's sampling program sought to portray the distribution of releases within the refinery, their management within the refinery, and ultimate releases leaving the refinery. Subsequent tests of blowdown stack and fugitive emissions further improved total release estimates. The initial study estimated that the refinery generates about 25,000 metric tons (t)/year of potential pollutants. Of these, about half are released from the refinery as airborne, waterborne, or land-disposed releases. Airborne releases comprise the majority of releases by mass, about 12,000 t/year. Most of the airborne releases are volatile organic compound hydrocarbons. The inventory sampling project and subsequent work identified differences with Toxic Release Inventory (TRI) values and standard emission factors (AP-42). The inventory and other data provided an opportunity to consider options for, and limitations of, specific pollution prevention or source reduction strategies

  12. Microemulsion-Based Mucoadhesive Buccal Wafers: Wafer Formation, In Vitro Release, and Ex Vivo Evaluation.

    Science.gov (United States)

    Pham, Minh Nguyet; Van Vo, Toi; Tran, Van-Thanh; Tran, Phuong Ha-Lien; Tran, Thao Truong-Dinh

    2017-10-01

    Microemulsion has the potentials to enhance dissolution as well as facilitate absorption and permeation of poorly water-soluble drugs through biological membranes. However, its application to govern a controlled release buccal delivery for local treatment has not been discovered. The aim of this study is to develop microemulsion-based mucoadhesive wafers for buccal delivery based on an incorporation of the microemulsion with mucoadhesive agents and mannitol. Ratio of oil to surfactant to water in the microemulsion significantly impacted quality of the wafers. Furthermore, the combination of carbopol and mannitol played a key role in forming the desired buccal wafers. The addition of an extra 50% of water to the formulation was suitable for wafer formation by freeze-drying, which affected the appearance and distribution of carbopol in the wafers. The amount of carbopol was critical for the enhancement of mucoadhesive properties and the sustained drug release patterns. Release study presented a significant improvement of the drug release profile following sustained release for 6 h. Ex vivo mucoadhesive studies provided decisive evidence to the increased retention time of wafers along with the increased carbopol content. The success of this study indicates an encouraging strategy to formulate a controlled drug delivery system by incorporating microemulsions into mucoadhesive wafers.

  13. 77 FR 1708 - Cooperative Research and Development Agreement: Technology To Provide Wireless Precise Time...

    Science.gov (United States)

    2012-01-11

    ... Systems (GPS) as a means of providing precise time. The alternative under consideration is a wireless... authorized by the Federal Technology Transfer Act of 1986 (Pub. L. 99- 502, codified at 15 U.S.C. 3710(a)). A..., and document at least one alternative to Global Positioning Systems (GPS) as a means of providing...

  14. Impact of a narrative medicine programme on healthcare providers' empathy scores over time.

    Science.gov (United States)

    Chen, Po-Jui; Huang, Chien-Da; Yeh, San-Jou

    2017-07-05

    The cultivation of empathy for healthcare providers is an important issue in medical education. Narrative medicine (NM) has been shown to foster empathy. To our knowledge, there has been no research that examines whether a NM programme affects multi-professional healthcare providers' empathy. Our study aims to fill this gap by investigating whether a NM programme effects multi-professional healthcare providers' empathy. A pre-post questionnaire method was used.142 participants (n = 122 females) who attended the NM programme were divided into single (n = 58) and team groups (n = 84) on the basis of inter-professional education during a period of 2 months. Perceptions of the NM programme were collected using our developed questionnaire. Empathy levels were measured using the Chinese version of Jefferson Scale of Empathy - Healthcare Providers Version (JSE-HP) - at three time points: prior to (Time 1), immediately after (T2), and 1.5 years (T3) after the programme. Participants' perceptions about the NM programme (n = 116; n = 96 females) suggested an in enhancement of empathy (90.5%). Empathy scores via the JSE-HP increased after the NM programme (T1 mean 111.05, T2 mean 116.19) and were sustainable for 1.5 years (T3 mean 116.04) for all participants (F(2297) = 3.74, p empathy scores was found (F(1298) = 5.33, p empathy scores at T2, sustaining at T3, but males demonstrating a slow rise in empathy scores over time. NM programme as an educational tool for empathy is feasible. However, further research is needed to examine gender difference as it might be that males and females respond differently to a NM programme intervention.

  15. National Atmospheric Release Advisory Center (NARAC) Capabilities for Homeland Security

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, G; Nasstrom, J; Baskett, R; Simpson, M

    2010-03-08

    The Department of Energy's National Atmospheric Release Advisory Center (NARAC) provides critical information during hazardous airborne releases as part of an integrated national preparedness and response strategy. Located at Lawrence Livermore National Laboratory, NARAC provides 24/7 tools and expert services to map the spread of hazardous material accidentally or intentionally released into the atmosphere. NARAC graphical products show affected areas and populations, potential casualties, and health effect or protective action guideline levels. LLNL experts produce quality-assured analyses based on field data to assist decision makers and responders. NARAC staff and collaborators conduct research and development into new science, tools, capabilities, and technologies in strategically important areas related to airborne transport and fate modeling and emergency response. This paper provides a brief overview of some of NARAC's activities, capabilities, and research and development.

  16. 2015 TRI National Analysis: Toxics Release Inventory Releases at Various Summary Levels

    Science.gov (United States)

    The TRI National Analysis is EPA's annual interpretation of TRI data at various summary levels. It highlights how toxic chemical wastes were managed, where toxic chemicals were released and how the 2015 TRI data compare to data from previous years. This dataset reports US state, county, large aquatic ecosystem, metro/micropolitan statistical area, and facility level statistics from 2015 TRI releases, including information on: number of 2015 TRI facilities in the geographic area and their releases (total, water, air, land); population information, including populations living within 1 mile of TRI facilities (total, minority, in poverty); and Risk Screening Environmental Indicators (RSEI) model related pounds, toxicity-weighted pounds, and RSEI score. The source of administrative boundary data is the 2013 cartographic boundary shapefiles. Location of facilities is provided by EPA's Facility Registry Service (FRS). Large Aquatic Ecosystems boundaries were dissolved from the hydrologic unit boundaries and codes for the United States, Puerto Rico, and the U.S. Virgin Islands. It was revised for inclusion in the National Atlas of the United States of America (November 2002), and updated to match the streams file created by the USGS National Mapping Division (NMD) for the National Atlas of the United States of America.

  17. Release properties of UC sub x and molten U targets

    CERN Document Server

    Roussière, B; Sauvage, J; Bajeat, O; Barre, N; Clapier, F; Cottereau, E; Donzaud, C; Ducourtieux, M; Essabaa, S; Guillemaud-Müller, D; Lau, C; Lefort, H; Liang, C F; Le Blanc, F; Müller, A C; Obert, J; Pauwels, N; Potier, J C; Pougheon, F; Proust, J; Sorlin, O; Verney, D; Wojtasiewicz, A

    2002-01-01

    The release properties of UC sub x and molten U thick targets associated with a Nier-Bernas ion source have been studied. Two experimental methods are used to extract the release time. Results are presented and discussed for Kr, Cd, I and Xe.

  18. Release of suppressed red spruce using canopy gap creation—Ecological restoration in the Central Appalachians

    Science.gov (United States)

    Rentch, J.S.; Ford, W. Mark; Schuler, T.S.; Palmer, J.; Diggins, Corinne A.

    2016-01-01

    Red spruce (Picea rubens) and red spruce-northern hardwood mixed stands once covered as much as 300,000 ha in the Central Appalachians, but now comprise no more than 21,000 ha. Recently, interest in restoration of this forest type has increased because red spruce forests provide habitat for a number of rare animal species. Our study reports the results of an understory red spruce release experiment in hardwood-dominated stands that have a small component of understory red spruce. In 2005, 188 target spruce were identified in sample plots at six locations in central West Virginia. We projected a vertical cylinder above the crown of all target spruces, and in 2007, we performed a release treatment whereby overtopping hardwoods were treated with herbicide using a stem injection technique. Release treatments removed 0–10% (Control), 11–50% (Low), 51–89% (Medium), and ≤90% (High) of the basal area of overtopping trees. We also took canopy photographs at the time of each remeasurement in 2007, 2010, and 2013, and compared basal removal treatments and resulting 2010 canopy openness and understory light values. The high treatment level provided significantly greater six-year dbh and height growth than the other treatment levels. Based on these results, we propose that a tree-centered release approach utilizing small canopy gaps that emulate the historical, gap-phase disturbance regime provides a good strategy for red spruce restoration in hardwood forests where overstory spruce are virtually absent, and where red spruce is largely relegated to the understory.

  19. Nanodiamond-based injectable hydrogel for sustained growth factor release: Preparation, characterization and in vitro analysis.

    Science.gov (United States)

    Pacelli, Settimio; Acosta, Francisca; Chakravarti, Aparna R; Samanta, Saheli G; Whitlow, Jonathan; Modaresi, Saman; Ahmed, Rafeeq P H; Rajasingh, Johnson; Paul, Arghya

    2017-08-01

    Nanodiamonds (NDs) represent an emerging class of carbon nanomaterials that possess favorable physical and chemical properties to be used as multifunctional carriers for a variety of bioactive molecules. Here we report the synthesis and characterization of a new injectable ND-based nanocomposite hydrogel which facilitates a controlled release of therapeutic molecules for regenerative applications. In particular, we have formulated a thermosensitive hydrogel using gelatin, chitosan and NDs that provides a sustained release of exogenous human vascular endothelial growth factor (VEGF) for wound healing applications. Addition of NDs improved the mechanical properties of the injectable hydrogels without affecting its thermosensitive gelation properties. Biocompatibility of the generated hydrogel was verified by in vitro assessment of apoptotic gene expressions and anti-inflammatory interleukin productions. NDs were complexed with VEGF and the inclusion of this complex in the hydrogel network enabled the sustained release of the angiogenic growth factor. These results suggest for the first time that NDs can be used to formulate a biocompatible, thermosensitive and multifunctional hydrogel platform that can function both as a filling agent to modulate hydrogel properties, as well as a delivery platform for the controlled release of bioactive molecules and growth factors. One of the major drawbacks associated with the use of conventional hydrogels as carriers of growth factors is their inability to control the release kinetics of the loaded molecules. In fact, in most cases, a burst release is inevitable leading to diminished therapeutic effects and unsuccessful therapies. As a potential solution to this issue, we hereby propose a strategy of incorporating ND complexes within an injectable hydrogel matrix. The functional groups on the surface of the NDs can establish interactions with the model growth factor VEGF and promote a prolonged release from the polymer network

  20. Oral matrix tablet formulations for concomitant controlled release of anti-tubercular drugs: design and in vitro evaluations.

    Science.gov (United States)

    Hiremath, Praveen S; Saha, Ranendra N

    2008-10-01

    The aim of the present investigation was to develop controlled release (C.R.) matrix tablet formulations of rifampicin and isoniazid combination, to study the design parameters and to evaluate in vitro release characteristics. In the present study, a series of formulations were developed with different release rates and duration using hydrophilic polymers hydroxypropyl methylcellulose (HPMC) and hydroxypropyl cellulose (HPC). The duration of rifampicin and isoniazid release could be tailored by varying the polymer type, polymer ratio and processing techniques. Further, Eudragit L100-55 was incorporated in the matrix tablets to compensate for the pH-dependent release of rifampicin. Rifampicin was found to follow linear release profile with time from HPMC formulations. In case of formulations with HPC, there was an initial higher release in simulated gastric fluid (SGF) followed by zero order release profiles in simulated intestinal fluid (SIFsp) for rifampicin. The release of isoniazid was found to be predominantly by diffusion mechanism in case of HPMC formulations, and with HPC formulations release was due to combination of diffusion and erosion. The initial release was sufficiently higher for rifampicin from HPC thus ruling out the need to incorporate a separate loading dose. The initial release was sufficiently higher for isoniazid in all formulations. Thus, with the use of suitable polymer or polymer combinations and with the proper optimization of the processing techniques it was possible to design the C.R. formulations of rifampicin and isoniazid combination that could provide the sufficient initial release and release extension up to 24h for both the drugs despite of the wide variations in their physicochemical properties.

  1. Optimal advanced credit releases in ecosystem service markets.

    Science.gov (United States)

    BenDor, Todd K; Guo, Tianshu; Yates, Andrew J

    2014-03-01

    Ecosystem service markets are popular policy tools for ecosystem protection. Advanced credit releases are an important factor affecting the supply side of ecosystem markets. Under an advanced credit release policy, regulators give ecosystem suppliers a fraction of the total ecosystem credits generated by a restoration project before it is verified that the project actually achieves the required ecological thresholds. In spite of their prominent role in ecosystem markets, there is virtually no regulatory or research literature on the proper design of advanced credit release policies. Using U.S. aquatic ecosystem markets as an example, we develop a principal-agent model of the behavior of regulators and wetland/stream mitigation bankers to determine and explore the optimal degree of advance credit release. The model highlights the tension between regulators' desire to induce market participation, while at the same time ensuring that bankers successfully complete ecological restoration. Our findings suggest several simple guidelines for strengthening advanced credit release policy.

  2. Diffusive spatio-temporal noise in a first-passage time model for intracellular calcium release

    KAUST Repository

    Flegg, Mark B.; Rüdiger, Sten; Erban, Radek

    2013-01-01

    The intracellular release of calcium from the endoplasmic reticulum is controlled by ion channels. The resulting calcium signals exhibit a rich spatio-temporal signature, which originates at least partly from microscopic fluctuations. While

  3. Kinetics of extracellular release of 14C-labelled organic carbon by submerged macrophytes

    International Nuclear Information System (INIS)

    Soendergaard, M.

    1981-01-01

    The release of extracellular organic carbon (EOC) by six submerged freswater macrophytes was measured in time course studies with a 14 C-technique. Incubation in light in an open water-flow system made it possible to assay the time courses of 14 C-fixation and the simultaneous release of labelled EOC. Heterotrophic utilization of the released products by epiphytic communities was measured. Two patterns of release kinetics were found: (1) Constant rates of release occurred during the incubations, (2) The rates still increased after 24 h of incubation. During the first hours of incubation the rates of release increased in all species. Elodea reached constant rates after 2-4 h and Littorella and Ceratophyllum demersum after about 20 h. In the experiments with C. submersum and Nitella the rates of release increased almost linearly during the entire incubation period. The kinetics of release were in agreement with the molecular weight distribution of the dissolved EOC measured with gel chromatography. Low molecular weight products ( 10000 Daltons) dominated the dissolved EOC released by C. submersum and Nitella. A large fraction (18-60%) of the total EOC could be recovered on filters with a pore size of 0.2 μm. This particulate fraction probably represents some abiotic removal. The quantities of relase were low in all species and did not exceed 0.9% of the photosynthetic carbon fixation. Heterotrophic uptake by the epiphytic communities was less than 10% of the EOC released. The results emphasize that the 14 C-labelling of extracellular products is a time dependent process. (author)

  4. Preliminary evaluation of an aqueous wax emulsion for controlled-release coating.

    Science.gov (United States)

    Walia, P S; Stout, P J; Turton, R

    1998-02-01

    The purpose of this work was to evaluate the use of an aqueous carnauba wax emulsion (Primafresh HS, Johnson Wax) in a spray-coating process. This involved assessing the effectiveness of the wax in sustaining the release of the drug, theophylline. Second, the process by which the drug was released from the wax-coated pellets was modeled. Finally, a method to determine the optimum blend of pellets with different wax thicknesses, in order to yield a zero-order release profile of the drug, was addressed. Nonpareil pellets were loaded with theophylline using a novel powder coating technique. These drug-loaded pellets were then coated with different levels of carnauba wax in a 6-in. diameter Plexiglas fluid bed with a 3.5-in. diameter Wurster partition. Drug release was measured using a spin-filter dissolution device. The study resulted in continuous carnauba wax coatings which showed sustained drug release profile characteristics typical of a barrier-type, diffusion-controlled system. The effect of varying wax thickness on the release profiles was investigated. It was observed that very high wax loadings would be required to achieve long sustained-release times. The diffusion model, developed to predict the release of the drug, showed good agreement with the experimental data. However, the data exhibited an initial lag-time for drug release which could not be predicted a priori based on the wax coating thickness. A method of mixing pellets with different wax thicknesses was proposed as a way to approximate zero-order release.

  5. Release mitigation spray safety systems for chemical demilitarization applications.

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jonathan; Tezak, Matthew Stephen; Brockmann, John E.; Servantes, Brandon; Sanchez, Andres L.; Tucker, Mark David; Allen, Ashley N.; Wilson, Mollye C.; Lucero, Daniel A.; Betty, Rita G.

    2010-06-01

    Sandia National Laboratories has conducted proof-of-concept experiments demonstrating effective knockdown and neutralization of aerosolized CBW simulants using charged DF-200 decontaminant sprays. DF-200 is an aqueous decontaminant, developed by Sandia National Laboratories, and procured and fielded by the US Military. Of significance is the potential application of this fundamental technology to numerous applications including mitigation and neutralization of releases arising during chemical demilitarization operations. A release mitigation spray safety system will remove airborne contaminants from an accidental release during operations, to protect personnel and limit contamination. Sandia National Laboratories recently (November, 2008) secured funding from the US Army's Program Manager for Non-Stockpile Chemical Materials Agency (PMNSCMA) to investigate use of mitigation spray systems for chemical demilitarization applications. For non-stockpile processes, mitigation spray systems co-located with the current Explosive Destruction System (EDS) will provide security both as an operational protective measure and in the event of an accidental release. Additionally, 'tented' mitigation spray systems for native or foreign remediation and recovery operations will contain accidental releases arising from removal of underground, unstable CBW munitions. A mitigation spray system for highly controlled stockpile operations will provide defense from accidental spills or leaks during routine procedures.

  6. Toxic chemical considerations for tank farm releases. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Van Keuren, J.C.

    1995-11-01

    This document provides a method of determining the toxicological consequences of accidental releases from Hanford Tank Farms. A determination was made of the most restrictive toxic chemicals that are expected to be present in the tanks. Concentrations were estimated based on the maximum sample data for each analyte in all the tanks in the composite. Composite evaluated were liquids and solids from single shell tanks, double shell tanks, flammable gas watch list tanks, as well as all solids, all liquids, head space gases, and 241-C-106 solids. A sum of fractions of the health effects was computed for each composite for unit releases based emergency response planning guidelines (ERPGs). Where ERPGs were not available for chemical compounds of interest, surrogate guidelines were established. The calculation method in this report can be applied to actual release scenarios by multiplying the sum of fractions by the release rate for continuous releases, or the release amount for puff releases. Risk guidelines are met if the product is less than for equal to one.

  7. Toxic chemical considerations for tank farm releases. Revision 1

    International Nuclear Information System (INIS)

    Van Keuren, J.C.

    1995-11-01

    This document provides a method of determining the toxicological consequences of accidental releases from Hanford Tank Farms. A determination was made of the most restrictive toxic chemicals that are expected to be present in the tanks. Concentrations were estimated based on the maximum sample data for each analyte in all the tanks in the composite. Composite evaluated were liquids and solids from single shell tanks, double shell tanks, flammable gas watch list tanks, as well as all solids, all liquids, head space gases, and 241-C-106 solids. A sum of fractions of the health effects was computed for each composite for unit releases based emergency response planning guidelines (ERPGs). Where ERPGs were not available for chemical compounds of interest, surrogate guidelines were established. The calculation method in this report can be applied to actual release scenarios by multiplying the sum of fractions by the release rate for continuous releases, or the release amount for puff releases. Risk guidelines are met if the product is less than for equal to one

  8. Optimization of ISOL targets based on Monte-Carlo simulations of ion release curves

    International Nuclear Information System (INIS)

    Mustapha, B.; Nolen, J.A.

    2003-01-01

    A detailed model for simulating release curves from ISOL targets has been developed. The full 3D geometry is implemented using Geant-4. Produced particles are followed individually from production to release. The delay time is computed event by event. All processes involved: diffusion, effusion and decay are included to obtain the overall release curve. By fitting to the experimental data, important parameters of the release process (diffusion coefficient, sticking time, ...) are extracted. They can be used to improve the efficiency of existing targets and design new ones more suitable to produce beams of rare isotopes

  9. Optimization of ISOL targets based on Monte-Carlo simulations of ion release curves

    CERN Document Server

    Mustapha, B

    2003-01-01

    A detailed model for simulating release curves from ISOL targets has been developed. The full 3D geometry is implemented using Geant-4. Produced particles are followed individually from production to release. The delay time is computed event by event. All processes involved: diffusion, effusion and decay are included to obtain the overall release curve. By fitting to the experimental data, important parameters of the release process (diffusion coefficient, sticking time, ...) are extracted. They can be used to improve the efficiency of existing targets and design new ones more suitable to produce beams of rare isotopes.

  10. INITIAL DATA RELEASE OF THE KEPLER-INT SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Greiss, S.; Steeghs, D.; Gaensicke, B. T. [Department of Physics, Astronomy and Astrophysics group, University of Warwick, CV4 7AL Coventry (United Kingdom); Martin, E. L. [INTA-CSIC Centro de Astrobiologia, Carretera de Ajalvir km 4, 28550 Torrejon de Ardoz (Spain); Groot, P. J.; Verbeek, K.; Jonker, P. G.; Scaringi, S. [Department of Astrophysics/IMAPP, Radboud University Nijmegen, P.O. Box 9010, 6500 GL Nijmegen (Netherlands); Irwin, M. J.; Gonzalez-Solares, E. [Cambridge Astronomy Survey Unit, Institute of Astronomy, University of Cambridge, Madingley Road, CB3 0HA Cambridge (United Kingdom); Greimel, R. [Institut fuer Physik, Karl-Franzen Universitaet Graz, Universitaetsplatz 5, 8010 Graz (Austria); Knigge, C. [School of Physics and Astronomy, University of Southampton, Southampton, Hampshire SO17 1BJ (United Kingdom); Ostensen, R. H. [Instituut voor Sterrenkunde, KU Leuven, Celestijnenlaan 200D, 3001 Leuven (Belgium); Drew, J. E.; Farnhill, H. [Centre for Astrophysics Research, University of Hertfordshire, College Lane, Hatfield AL10 9AB (United Kingdom); Drake, J.; Wright, N. J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Ripepi, V. [INAF-Osservatorio Astronomico di Capodimonte, via Moiariello 16, Naples I-80131 (Italy); Southworth, J. [Astrophysics Group, Keele University, Newcastle-under-Lyme ST5 5BG (United Kingdom); Still, M., E-mail: s.greiss@warwick.ac.uk [NASA Ames Research Center, M/S 244-40, Moffett Field, CA 94035 (United States); and others

    2012-07-15

    This paper describes the first data release of the Kepler-INT Survey (KIS) that covers a 116 deg{sup 2} region of the Cygnus and Lyra constellations. The Kepler field is the target of the most intensive search for transiting planets to date. Despite the fact that the Kepler mission provides superior time-series photometry, with an enormous impact on all areas of stellar variability, its field lacks optical photometry complete to the confusion limit of the Kepler instrument necessary for selecting various classes of targets. For this reason, we follow the observing strategy and data reduction method used in the IPHAS and UVEX galactic plane surveys in order to produce a deep optical survey of the Kepler field. This initial release concerns data taken between 2011 May and August, using the Isaac Newton Telescope on the island of La Palma. Four broadband filters were used, U, g, r, i, as well as one narrowband one, H{alpha}, reaching down to a 10{sigma} limit of {approx}20th mag in the Vega system. Observations covering {approx}50 deg{sup 2}, thus about half of the field, passed our quality control thresholds and constitute this first data release. We derive a global photometric calibration by placing the KIS magnitudes as close as possible to the Kepler Input Catalog (KIC) photometry. The initial data release catalog containing around 6 million sources from all the good photometric fields is available for download from the KIS Web site (www.astro.warwick.ac.uk/research/kis/) as well as via MAST (KIS magnitudes can be retrieved using the MAST enhanced target search page http://archive.stsci.edu/kepler/kepler{sub f}ov/search.php and also via Casjobs at MAST Web site http://mastweb.stsci.edu/kplrcasjobs/).

  11. INITIAL DATA RELEASE OF THE KEPLER-INT SURVEY

    International Nuclear Information System (INIS)

    Greiss, S.; Steeghs, D.; Gänsicke, B. T.; Martín, E. L.; Groot, P. J.; Verbeek, K.; Jonker, P. G.; Scaringi, S.; Irwin, M. J.; González-Solares, E.; Greimel, R.; Knigge, C.; Østensen, R. H.; Drew, J. E.; Farnhill, H.; Drake, J.; Wright, N. J.; Ripepi, V.; Southworth, J.; Still, M.

    2012-01-01

    This paper describes the first data release of the Kepler-INT Survey (KIS) that covers a 116 deg 2 region of the Cygnus and Lyra constellations. The Kepler field is the target of the most intensive search for transiting planets to date. Despite the fact that the Kepler mission provides superior time-series photometry, with an enormous impact on all areas of stellar variability, its field lacks optical photometry complete to the confusion limit of the Kepler instrument necessary for selecting various classes of targets. For this reason, we follow the observing strategy and data reduction method used in the IPHAS and UVEX galactic plane surveys in order to produce a deep optical survey of the Kepler field. This initial release concerns data taken between 2011 May and August, using the Isaac Newton Telescope on the island of La Palma. Four broadband filters were used, U, g, r, i, as well as one narrowband one, Hα, reaching down to a 10σ limit of ∼20th mag in the Vega system. Observations covering ∼50 deg 2 , thus about half of the field, passed our quality control thresholds and constitute this first data release. We derive a global photometric calibration by placing the KIS magnitudes as close as possible to the Kepler Input Catalog (KIC) photometry. The initial data release catalog containing around 6 million sources from all the good photometric fields is available for download from the KIS Web site (www.astro.warwick.ac.uk/research/kis/) as well as via MAST (KIS magnitudes can be retrieved using the MAST enhanced target search page http://archive.stsci.edu/kepler/kepler_fov/search.php and also via Casjobs at MAST Web site http://mastweb.stsci.edu/kplrcasjobs/).

  12. The release of silver nanoparticles from commercial toothbrushes

    Energy Technology Data Exchange (ETDEWEB)

    Mackevica, Aiga, E-mail: aima@env.dtu.dk; Olsson, Mikael Emil; Hansen, Steffen Foss

    2017-01-15

    Highlights: • Ag and Ag nanoparticle release was measured from two types of toothbrushes. • Maximum release for entire intended product use period was 10 ng Ag per toothbrush. • Released Ag nanoparticles had median sizes from 42 to 47 nm. • Up to 2.8% of total Ag released was detected in nanoparticulate form. - Abstract: The use of silver nanoparticles (NPs) in commercial products has become increasingly common in the past decade, mostly due to their antimicrobial properties. Using Ag NP-containing articles may lead to particle release, which raises concern of human and environmental safety. The published literature addressing particle release is scarce, especially when it comes to quantifying exposure to NPs specifically. In this study, we have experimentally investigated the release of total Ag and Ag NP from commercially available toothbrushes i.e. biodegradable toothbrushes for adults and toothbrushes for children. Toothbrushes were immersed and abraded in tap water for 24 h corresponding to more than the whole intended usage time of a toothbrush. The total amount of released Ag was quantified by inductively coupled plasma—mass spectrometry (ICP-MS) analysis, and the Ag NPs were characterized by single particle ICP-MS and transmission electron microscopy (TEM). The median size of the released Ag NPs ranged from 42 to 47 nm, and the maximum total Ag release was 10.2 ng per toothbrush. The adult toothbrushes were generally releasing more total Ag and NPs than children toothbrushes. In conclusion, our results indicate that the use of Ag NP-impregnated toothbrushes can cause consumer as well as environmental exposure to Ag NPs.

  13. The release of silver nanoparticles from commercial toothbrushes

    International Nuclear Information System (INIS)

    Mackevica, Aiga; Olsson, Mikael Emil; Hansen, Steffen Foss

    2017-01-01

    Highlights: • Ag and Ag nanoparticle release was measured from two types of toothbrushes. • Maximum release for entire intended product use period was 10 ng Ag per toothbrush. • Released Ag nanoparticles had median sizes from 42 to 47 nm. • Up to 2.8% of total Ag released was detected in nanoparticulate form. - Abstract: The use of silver nanoparticles (NPs) in commercial products has become increasingly common in the past decade, mostly due to their antimicrobial properties. Using Ag NP-containing articles may lead to particle release, which raises concern of human and environmental safety. The published literature addressing particle release is scarce, especially when it comes to quantifying exposure to NPs specifically. In this study, we have experimentally investigated the release of total Ag and Ag NP from commercially available toothbrushes i.e. biodegradable toothbrushes for adults and toothbrushes for children. Toothbrushes were immersed and abraded in tap water for 24 h corresponding to more than the whole intended usage time of a toothbrush. The total amount of released Ag was quantified by inductively coupled plasma—mass spectrometry (ICP-MS) analysis, and the Ag NPs were characterized by single particle ICP-MS and transmission electron microscopy (TEM). The median size of the released Ag NPs ranged from 42 to 47 nm, and the maximum total Ag release was 10.2 ng per toothbrush. The adult toothbrushes were generally releasing more total Ag and NPs than children toothbrushes. In conclusion, our results indicate that the use of Ag NP-impregnated toothbrushes can cause consumer as well as environmental exposure to Ag NPs.

  14. Ultrasound-assisted endoscopic partial plantar fascia release.

    Science.gov (United States)

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  15. Time-resolved x-ray diffraction from frog skeletal muscle during shortening against an inertial load and a quick release

    International Nuclear Information System (INIS)

    Amemiya, Yoshiyuki; Hashizume, Hiroo; Tameyasu, Tsukasa; Tanaka, Hidehiro; Sugi, Haruo.

    1980-01-01

    A group of Japanese researchers conducted, for the first time in this field, experiments on time-resolved x-ray diffraction of frog (bullfrog, Rana catesbeiana) skeletal muscle in conditions where both the force and the muscle length change with time. During an isotonic twitch under a load of about 0.3 P 0 , the intensity ratio started falling on stimulation and reached a minimum value of 0.5 - 0.6 at the early shortening phase, which was maintained until the beginning of relaxation. Except that the minimum value was not retained until the start of relaxation, the same was observed during a twitch against an inertial load whereby the peak force exerted by the muscle was about 0.4 P 0 . The results may be taken to indicate that the change in the intensity ratio reflects not the time course of shortening but that of force generation. When a quick release (3 - 4% of muscle length) was applied during the rising phase of an isometric twitch, the intensity ratio showed no distinct change. Judging from tentative calculation results, however, the foregoing result is subject to further experiments with a much improved time resolution of the measurements. (Kitajima, A.)

  16. Stimuli-Responsive Materials for Controlled Release Applications

    KAUST Repository

    Li, Song

    2015-04-01

    The controlled release of therapeutics has been one of the major challenges for scientists and engineers during the past three decades. To address this outstanding problem, the design and fabrication of stimuli-responsive materials are pursued to guarantee the controlled release of cargo at a specific time and with an accurate amount. Upon applying different stimuli such as light, magnetic field, heat, pH change, enzymes or redox, functional materials change their physicochemical properties through physical transformation or chemical reactions, allowing the release of payload agents on demand. This dissertation studied three stimuli-responsive membrane systems for controlled release from films of macro sizes to microcapsules of nano sizes. The first membrane system is a polymeric composite film which can decrease and sustain diffusion upon light irradiation. The photo-response of membranes is based on the photoreaction of cinnamic derivatives. The second one is composite membrane which can improve diffusion upon heating. The thermo-response of membranes comes from the volume phase transition ability of hydrogels. The third one is microcapsule which can release encapsulated agents upon light irradiation. The photo-response of capsules results from the photoreaction of nitrobenzyl derivatives. The study on these membrane systems reveals that stimuli-responsive release can be achieved by utilizing different functional materials on either macro or micro level. Based on the abundant family of smart materials, designing and fabricating stimuli-responsive systems shall lead to various advanced release processes on demand for biomedical applications.

  17. Novel Caffeic Acid Nanocarrier: Production, Characterization, and Release Modeling

    Directory of Open Access Journals (Sweden)

    Milad Fathi

    2013-01-01

    Full Text Available This paper deals with the development of novel nanocarriers using layer by layer carbohydrate coating of caffeic acid loaded solid lipid nanoparticles (SLNs to improve stability and colon delivery of the poorly water-soluble caffeic acid. Three biopolymers (chitosan, alginate, and pectin in different concentrations (0.1, 0.25, and 0.5% were electrostatically coated over the SLN surface. The size and zeta potential of produced nanocarriers were measured using photon correlation spectroscopy. Mathematical models (i.e., zero-order, first-order, Higuchi, Ritger-Peppas, reciprocal powered time, Weibull, and quadratic models were used to describe the release and kinetic modeling in gastrointestinal solution (GIS. Also, antioxidant activity of caffeic acid during the release in GIS was investigated using DPPH and reducing activity methods. The prepared treatments coated by alginate-chitosan as well as pectin-chitosan coated SLN at the concentration of 0.1% showed nanosized bead; the latter efficiently retarded the release of caffeic acid in gastric media up to 2.5 times higher than that of SLN. Zeta potential values of coated samples were found to significantly increase in comparison to SLN indicating the higher stability of produced nanocarriers. Antioxidant activity of caffeic acid after gastric release did not result in the same trend as observed for caffeic acid release from different treatments; however, in line with less caffeic acid release in the intestine solution by the effect of coating, lower antioxidant activity was determined at the end stage of the experiment.

  18. News/Press Releases

    Data.gov (United States)

    Office of Personnel Management — A press release, news release, media release, press statement is written communication directed at members of the news media for the purpose of announcing programs...

  19. Comparison of monaural (CMR) and binaural (BMLD) masking release

    NARCIS (Netherlands)

    Par, van de S.L.J.D.E.; Kohlrausch, A.G.

    1998-01-01

    Release of masking for a sinusoidal signal of 5 kHz masked by a 25-Hz-wide noise band centered around 5 kHz was measured. The masking release was provided by a second noise band that was comodulated with the on-frequency masker band. For CMR configurations the second noise band was centered at 3 kHz

  20. Critical review of controlled release packaging to improve food safety and quality.

    Science.gov (United States)

    Chen, Xi; Chen, Mo; Xu, Chenyi; Yam, Kit L

    2018-03-19

    Controlled release packaging (CRP) is an innovative technology that uses the package to release active compounds in a controlled manner to improve safety and quality for a wide range of food products during storage. This paper provides a critical review of the uniqueness, design considerations, and research gaps of CRP, with a focus on the kinetics and mechanism of active compounds releasing from the package. Literature data and practical examples are presented to illustrate how CRP controls what active compounds to release, when and how to release, how much and how fast to release, in order to improve food safety and quality.

  1. Optimal selection of the time of hazardous operations, and prediction of consequences of atmospheric releases of harmful matter: the 'Kursk' submarine study

    International Nuclear Information System (INIS)

    Baklanov, A.; Havskov Sorensen, J.; Mahura, A.

    2003-01-01

    accidental 'Kursk' nuclear submarine. On 12 August 2000, after an accident during exercises of the Russian Northern Fleet (RNF), Kursk sunk with its 118 crew members in the Barents Sea. The following operations of lifting, transportation and decommissioning of Kursk (after the preparation stage) involved phases with different risk levels. It would probably have been helpful to the operation management to carry out a risk assessment before the phases started, as well as to forecast and evaluate the possible airborne contamination and consequences using operational dispersion modelling during the high and medium risk phases of the Operation. It is clear now that the risk of a severe accident with a large atmospheric release from Kursk was quite low, but at the moment of the accident and during stages of the operational forecasting such analysis of possible risk were not available. An example of the maximum reaching distance, which might be reached during the first day of atmospheric transport, and the maximum possible impact zone indicating the boundaries of a territory with the highest probability of being reached during the first day of transport from the site is provided as well as an example of the average time integrated concentration of 137 CS within the surface layer. fig. 1 (author)

  2. Estradiol potentiation of gonadotropin-releasing hormone responsiveness in the anterior pituitary is mediated by an increase in gonadotropin-releasing hormone receptors

    International Nuclear Information System (INIS)

    Menon, M.; Peegel, H.; Katta, V.

    1985-01-01

    In order to investigate the mechanism by which 17 beta-estradiol potentiates the action of gonadotropin-releasing hormone on the anterior pituitary in vitro, cultured pituitary cells from immature female rats were used as the model system. Cultures exposed to estradiol at concentrations ranging from 10(-10) to 10(-6) mol/L exhibited a significant augmentation of luteinizing hormone release in response to a 4-hour gonadotropin-releasing hormone (10 mumol/L) challenge at a dose of 10(-9) mol/L compared to that of control cultures. The estradiol augmentation of luteinizing hormone release was also dependent on the duration of estradiol exposure. When these cultures were incubated with tritium-labeled L-leucine, an increase in incorporation of radiolabeled amino acid into total proteins greater than that in controls was observed. A parallel stimulatory effect of estradiol on iodine 125-labeled D-Ala6 gonadotropin-releasing hormone binding was observed. Cultures incubated with estradiol at different concentrations and various lengths of time showed a significant increase in gonadotropin-releasing hormone binding capacity and this increase was abrogated by cycloheximide. Analysis of the binding data showed that the increase in gonadotropin-releasing hormone binding activity was due to a change in the number of gonadotropin-releasing hormone binding sites rather than a change in the affinity. These results suggest that (1) estradiol treatment increases the number of pituitary receptors for gonadotropin-releasing hormone, (2) the augmentary effect of estradiol on luteinizing hormone release at the pituitary level might be mediated, at least in part, by the increase in the number of binding sites of gonadotropin-releasing hormone, and (3) new protein synthesis may be involved in estradiol-mediated gonadotropin-releasing hormone receptor induction

  3. Extended-Release Once-Daily Formulation of Tofacitinib: Evaluation of Pharmacokinetics Compared With Immediate-Release Tofacitinib and Impact of Food.

    Science.gov (United States)

    Lamba, Manisha; Wang, Rong; Fletcher, Tracey; Alvey, Christine; Kushner, Joseph; Stock, Thomas C

    2016-11-01

    Tofacitinib is an oral Janus kinase inhibitor for the treatment of rheumatoid arthritis. An extended-release (XR) formulation has been designed to provide a once-daily (QD) dosing option to patients to achieve comparable pharmacokinetic (PK) parameters to the twice-daily immediate-release (IR) formulation. We conducted 2 randomized, open-label, phase 1 studies in healthy volunteers. Study A characterized single-dose and steady-state PK of tofacitinib XR 11 mg QD and intended to demonstrate equivalence of exposure under single-dose and steady-state conditions to tofacitinib IR 5 mg twice daily. Study B assessed the effect of a high-fat meal on the bioavailability of tofacitinib from the XR formulation. Safety and tolerability were monitored in both studies. In study A (N = 24), the XR and IR formulations achieved time to maximum plasma concentration at 4 hours and 0.5 hours postdose, respectively; terminal half-life was 5.9 hours and 3.2 hours, respectively. Area under plasma concentration-time curve (AUC) and maximum plasma concentration (C max ) after single- and multiple-dose administration were equivalent between the XR and IR formulations. In study B (N = 24), no difference in AUC was observed for fed vs fasted conditions. C max increased by 27% under the fed state. On repeat administration, negligible accumulation (Tofacitinib administration as an XR or IR formulation was generally well tolerated in these studies. © 2016, The Authors. The Journal of Clinical Pharmacology published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.

  4. Diffusive spatio-temporal noise in a first-passage time model for intracellular calcium release

    KAUST Repository

    Flegg, Mark B.

    2013-01-01

    The intracellular release of calcium from the endoplasmic reticulum is controlled by ion channels. The resulting calcium signals exhibit a rich spatio-temporal signature, which originates at least partly from microscopic fluctuations. While stochasticity in the gating transition of ion channels has been incorporated into many models, the distribution of calcium is usually described by deterministic reaction-diffusion equations. Here we test the validity of the latter modeling approach by using two different models to calculate the frequency of localized calcium signals (calcium puffs) from clustered IP3 receptor channels. The complexity of the full calcium system is here limited to the basic opening mechanism of the ion channels and, in the mathematical reduction simplifies to the calculation of a first passage time. Two models are then studied: (i) a hybrid model, where channel gating is treated stochastically, while calcium concentration is deterministic and (ii) a fully stochastic model with noisy channel gating and Brownian calcium ion motion. The second model utilises the recently developed two-regime method [M. B. Flegg, S. J. Chapman, and R. Erban, "The two-regime method for optimizing stochastic reaction-diffusion simulations," J. R. Soc., Interface 9, 859-868 (2012)] in order to simulate a large domain with precision required only near the Ca2+ absorbing channels. The expected time for a first channel opening that results in a calcium puff event is calculated. It is found that for a large diffusion constant, predictions of the interpuff time are significantly overestimated using the model (i) with a deterministic non-spatial calcium variable. It is thus demonstrated that the presence of diffusive noise in local concentrations of intracellular Ca2+ ions can substantially influence the occurrence of calcium signals. The presented approach and results may also be relevant for other cell-physiological first-passage time problems with small ligand concentration

  5. Externally controlled triggered-release of drug from PLGA micro and nanoparticles.

    Directory of Open Access Journals (Sweden)

    Xin Hua

    Full Text Available Biofilm infections are extremely hard to eradicate and controlled, triggered and controlled drug release properties may prolong drug release time. In this study, the ability to externally control drug release from micro and nanoparticles was investigated. We prepared micro/nanoparticles containing ciprofloxacin (CIP and magnetic nanoparticles encapsulated in poly (lactic-co-glycolic acid PLGA. Both micro/nanoparticles were observed to have narrow size distributions. We investigated and compared their passive and externally triggered drug release properties based on their different encapsulation structures for the nano and micro systems. In passive release studies, CIP demonstrated a fast rate of release in first 2 days which then slowed and sustained release for approximately 4 weeks. Significantly, magnetic nanoparticles containing systems all showed ability to have triggered drug release when exposed to an external oscillating magnetic field (OMF. An experiment where the OMF was turned on and off also confirmed the ability to control the drug release in a pulsatile manner. The magnetically triggered release resulted in a 2-fold drug release increase compared with normal passive release. To confirm drug integrity following release, the antibacterial activity of released drug was evaluated in Pseudomonas aeruginosa biofilms in vitro. CIP maintained its antimicrobial activity after encapsulation and triggered release.

  6. Externally controlled triggered-release of drug from PLGA micro and nanoparticles.

    Science.gov (United States)

    Hua, Xin; Tan, Shengnan; Bandara, H M H N; Fu, Yujie; Liu, Siguo; Smyth, Hugh D C

    2014-01-01

    Biofilm infections are extremely hard to eradicate and controlled, triggered and controlled drug release properties may prolong drug release time. In this study, the ability to externally control drug release from micro and nanoparticles was investigated. We prepared micro/nanoparticles containing ciprofloxacin (CIP) and magnetic nanoparticles encapsulated in poly (lactic-co-glycolic acid) PLGA. Both micro/nanoparticles were observed to have narrow size distributions. We investigated and compared their passive and externally triggered drug release properties based on their different encapsulation structures for the nano and micro systems. In passive release studies, CIP demonstrated a fast rate of release in first 2 days which then slowed and sustained release for approximately 4 weeks. Significantly, magnetic nanoparticles containing systems all showed ability to have triggered drug release when exposed to an external oscillating magnetic field (OMF). An experiment where the OMF was turned on and off also confirmed the ability to control the drug release in a pulsatile manner. The magnetically triggered release resulted in a 2-fold drug release increase compared with normal passive release. To confirm drug integrity following release, the antibacterial activity of released drug was evaluated in Pseudomonas aeruginosa biofilms in vitro. CIP maintained its antimicrobial activity after encapsulation and triggered release.

  7. A space release/deployment system actuated by shape memory wires

    Science.gov (United States)

    Fragnito, Marino; Vetrella and, Sergio

    2002-11-01

    In this paper, the design of an innovative hold down/release and deployment device actuated by shape memory wires, to be used for the first time for the S MA RT microsatellite solar wings is shown. The release and deployment mechanisms are actuated by a Shape Memory wire (Nitinol), which allows a complete symmetrical and synchronous release, in a very short time, of the four wings in pairs. The hold down kinematic mechanism is preloaded to avoid vibration nonlinearities and unwanted deployment at launch. The deployment mechanism is a simple pulley system. The stiffness of the deployed panel-hinge system needs to be dimensioned in order to meet the on-orbit requirement for attitude control. One-way roller clutches are used to keep the panel at the desired angle during the mission. An ad hoc software has been developed to simulate both the release and deployment operations, coupling the SMA wire behavior with the system mechanics.

  8. Drug Release from Phase-Changeable Nanodroplets Triggered by Low-Intensity Focused Ultrasound

    Science.gov (United States)

    Cao, Yang; Chen, Yuli; Yu, Tao; Guo, Yuan; Liu, Fengqiu; Yao, Yuanzhi; Li, Pan; Wang, Dong; Wang, Zhigang; Chen, Yu; Ran, Haitao

    2018-01-01

    Background: As one of the most effective triggers with high tissue-penetrating capability and non-invasive feature, ultrasound shows great potential for controlling the drug release and enhancing the chemotherapeutic efficacy. In this study, we report, for the first time, construction of a phase-changeable drug-delivery nanosystem with programmable low-intensity focused ultrasound (LIFU) that could trigger drug-release and significantly enhance anticancer drug delivery. Methods: Liquid-gas phase-changeable perfluorocarbon (perfluoropentane) and an anticancer drug (doxorubicin) were simultaneously encapsulated in two kinds of nanodroplets. By triggering LIFU, the nanodroplets could be converted into microbubbles locally in tumor tissues for acoustic imaging and the loaded anticancer drug (doxorubicin) was released after the microbubble collapse. Based on the acoustic property of shell materials, such as shell stiffness, two types of nanodroplets (lipid-based nanodroplets and PLGA-based nanodroplets) were activated by different acoustic pressure levels. Ultrasound irradiation duration and power of LIFU were tested and selected to monitor and control the drug release from nanodroplets. Various ultrasound energies were introduced to induce the phase transition and microbubble collapse of nanodroplets in vitro (3 W/3 min for lipid nanodroplets; 8 W/3 min for PLGA nanodroplets). Results: We detected three steps in the drug-releasing profiles exhibiting the programmable patterns. Importantly, the intratumoral accumulation and distribution of the drug with LIFU exposure were significantly enhanced, and tumor proliferation was substantially inhibited. Co-delivery of two drug-loaded nanodroplets could overcome the physical barriers of tumor tissues during chemotherapy. Conclusion: Our study provides a new strategy for the efficient ultrasound-triggered chemotherapy by nanocarriers with programmable LIFU capable of achieving the on-demand drug release. PMID:29507623

  9. An investigation of effects of modification processes on physical properties and mechanism of drug release for sustaining drug release from modified rice

    Energy Technology Data Exchange (ETDEWEB)

    Ngo, Vuong Duy; Luu, Thinh Duc; Van Vo, Toi [Pharmaceutical Engineering Laboratory, Biomedical Engineering Department, International University, Vietnam National University, Ho Chi Minh City (Viet Nam); Tran, Van-Thanh [Faculty of Pharmacy, University of Medicine and Pharmacy, Ho Chi Minh City (Viet Nam); Duan, Wei [School of Medicine, Deakin University, Pigdons Road, Waurn Ponds, Victoria (Australia); Tran, Phuong Ha-Lien, E-mail: phuong.tran1@deakin.edu.au [School of Medicine, Deakin University, Pigdons Road, Waurn Ponds, Victoria (Australia); Tran, Thao Truong-Dinh, E-mail: ttdthao@hcmiu.edu.vn [Pharmaceutical Engineering Laboratory, Biomedical Engineering Department, International University, Vietnam National University, Ho Chi Minh City (Viet Nam)

    2016-10-01

    The aim of this study was to investigate the effect of modification processes on physical properties and explain the mechanism of sustained drug release from modified rice (MR). Various types of Vietnamese rice were introduced in the study as the matrices of sustained release dosage form. Rice was thermally modified in water for a determined temperature at different times with a simple process. Then tablets containing MR and isradipine, the model drug, were prepared to investigate the capability of sustained drug release. Scanning electron microscopy (SEM) was used to determine different morphologies between MR formulations. Flow property of MR was analyzed by Hausner ratio and Carr's indices. The dissolution rate and swelling/erosion behaviors of tablets were evaluated at pH 1.2 and pH 6.8 at 37 ± 0.5 °C. The matrix tablet containing MR showed a sustained release as compared to the control. The SEM analyses and swelling/erosion studies indicated that the morphology as well as swelling/erosion rate of MR were modulated by modification time, drying method and incubation. It was found that the modification process was crucial because it could highly affect the granule morphologies and hence, leading to the change of flowability and swelling/erosion capacity for sustained release of drug. - Highlights: • Modification process affected granule morphologies and flowability of modified rice. • Modification process affected swelling/erosion capacity for drug sustained release. • Freeze-drying could decrease the erosion as well as increase the swelling rate.

  10. An investigation of effects of modification processes on physical properties and mechanism of drug release for sustaining drug release from modified rice

    International Nuclear Information System (INIS)

    Ngo, Vuong Duy; Luu, Thinh Duc; Van Vo, Toi; Tran, Van-Thanh; Duan, Wei; Tran, Phuong Ha-Lien; Tran, Thao Truong-Dinh

    2016-01-01

    The aim of this study was to investigate the effect of modification processes on physical properties and explain the mechanism of sustained drug release from modified rice (MR). Various types of Vietnamese rice were introduced in the study as the matrices of sustained release dosage form. Rice was thermally modified in water for a determined temperature at different times with a simple process. Then tablets containing MR and isradipine, the model drug, were prepared to investigate the capability of sustained drug release. Scanning electron microscopy (SEM) was used to determine different morphologies between MR formulations. Flow property of MR was analyzed by Hausner ratio and Carr's indices. The dissolution rate and swelling/erosion behaviors of tablets were evaluated at pH 1.2 and pH 6.8 at 37 ± 0.5 °C. The matrix tablet containing MR showed a sustained release as compared to the control. The SEM analyses and swelling/erosion studies indicated that the morphology as well as swelling/erosion rate of MR were modulated by modification time, drying method and incubation. It was found that the modification process was crucial because it could highly affect the granule morphologies and hence, leading to the change of flowability and swelling/erosion capacity for sustained release of drug. - Highlights: • Modification process affected granule morphologies and flowability of modified rice. • Modification process affected swelling/erosion capacity for drug sustained release. • Freeze-drying could decrease the erosion as well as increase the swelling rate.

  11. A comparison of N-methyl-D-aspartate-evoked release of adenosine and [3H]norepinephrine from rat cortical slices

    International Nuclear Information System (INIS)

    Hoehn, K.; Craig, C.G.; White, T.D.

    1990-01-01

    Tetrodotoxin reduced N-methyl-D-aspartate (NMDA)-evoked release of adenosine by 35% but virtually abolished [3H]norepinephrine release. Although [3H]norepinephrine release from rat cortical slices evoked by 500 microM NMDA was abolished by 1.2 mM Mg++, which produces a voltage-sensitive, uncompetitive block of NMDA-channels, adenosine release was increased in the presence of Mg++. Partial depolarization with 12 mM K+ relieved the Mg++ block of 500 microM NMDA-evoked [3H]norepinephrine release but did not affect adenosine release, indicating that a Mg++ requirement for the adenosine release process per se cannot account for this discrepancy. NMDA was 33 times more potent in releasing adenosine than [3H]norepinephrine. At submaximal concentrations of NMDA (10 and 20 microM), adenosine release was augmented in Mg+(+)-free medium. Although a high concentration of the uncompetitive NMDA antagonist MK-801 [(+)-5-methyl-10,11,dihydro-5H-dibenzo[a,d]cyclohepten-5-10-imine maleate] (3 microM) blocked NMDA-evoked release of [3H]norepinephrine and adenosine, a lower concentration (300 nM) decreased NMDA-evoked [3H]norepinephrine release by 66% without affecting adenosine release. These findings suggest that maximal adenosine release occurs when relatively few NMDA receptors are activated, raising the possibility that spare receptors exist for NMDA-evoked adenosine release. Rather than acting as a protectant against excessive NMDA excitation, released adenosine might provide an inhibitory threshold which must be overcome for NMDA-mediated neurotransmission to proceed

  12. Electrochemically controlled release of anticancer drug methotrexate using nanostructured polypyrrole modified with cetylpyridinium: Release kinetics investigation

    International Nuclear Information System (INIS)

    Alizadeh, Naader; Shamaeli, Ehsan

    2014-01-01

    A new simple strategy for direct electrochemical incorporation of chemotherapeutic methotrexate (MTX) into conductive polypyrrole (PPy) has been suggested for an electrochemically controlled loading and release system. Electropolymerization of MTX doped polypyrrole yielded poor quality with low efficiency of doping, but a well-doped, nanostructure and increased capacity of drug loading (24.5 mg g −1 ) has been obtained in the presence of cetylpyridinium (CP) as a modifier. When CP was preloaded onto PPy, the hydrophobic surface of the PPy serves as a backbone to which the hydrophobic chain of the CP can be attached. Electrostatic interaction between cationic CP with anionic MTX and aromatic interaction between pyridinium head of CP with pyrimidine and pyrazine rings of MTX increases drug doping. Then release kinetics were investigated at various applied potentials and temperatures. Kinetics analysis based on Avrami's equation showed that the drug release was controlled and accelerated by increasing temperature and negative potential and sustained by increasing positive potential. At open circuit condition, the release parameter (n) represented a diffusive mechanism and at applying electrochemical potentials, a first-order mode. Activation energy parameters (E a , ΔG ≠ , ΔH ≠ and ΔS ≠ ) and half-life time (t 1/2 ) of drug release are also analyzed as a function of applied potential. The nanostructured polymer films (PPy/CP/MTX) were characterized by several techniques: scanning electron microscopy, Furrier transforms Infrared, UV-vis spectroscopy. Overall, our results demonstrate that the PPy/CP/MTX films, combined with electrical stimulation, permit a programmable release of MTX by altering the interaction strength between the PPy/CP and MTX

  13. Metallic ion release from biocompatible cobalt-based alloy

    Directory of Open Access Journals (Sweden)

    Dimić Ivana D.

    2014-01-01

    Full Text Available Metallic biomaterials, which are mainly used for the damaged hard tissue replacements, are materials with high strength, excellent toughness and good wear resistance. The disadvantages of metals as implant materials are their susceptibility to corrosion, the elastic modulus mismatch between metals and human hard tissues, relatively high density and metallic ion release which can cause serious health problems. The aim of this study was to examine metallic ion release from Co-Cr-Mo alloy in artificial saliva. In that purpose, alloy samples were immersed into artificial saliva with different pH values (4.0, 5.5 and 7.5. After a certain immersion period (1, 3 and 6 weeks the concentrations of released ions were determined using Inductively Coupled Plasma - Mass Spectrophotometer (ICP-MS. The research findings were used in order to define the dependence between the concentration of released metallic ions, artificial saliva pH values and immersion time. The determined released metallic ions concentrations were compared with literature data in order to describe and better understand the phenomenon of metallic ion release from the biocompatible cobalt-based alloy. [Projekat Ministarstva nauke Republike Srbije, br. III 46010 i br. ON 174004

  14. Heat release rate from the combustion of uranium

    International Nuclear Information System (INIS)

    Solbrig, C.W.

    1995-01-01

    Fuel treatment is planned at the Argonne National Laboratory on EBR-II spent fuel. The electrochemical treatment process is carried out in a cell with an argon atmosphere to prevent any reaction. The amount of fuel processed at any time is limited by the amount of energy which could be released by metal combustion if air is inadvertently allowed into the cell since the heat release would increase the cell pressure. The cell pressure is required to be below atmospheric even if combustion occurs to ensure no cell gas/aerosol is released to the environment. Metal fires can release large amounts of heat. In certain configurations such as fine particulate, metal can be pyrophoric at room temperature. When the metal is a nuclear fuel, it is important to be able to predict the reaction/heat release rate if the metal is inadvertently exposed to air. A realistic combustion model is needed to predict heat release rates for the many different flow and transport configurations which exist in the various fuel processing steps. A model for the combustion of uranium is developed here which compares satisfactorily to experimental data

  15. 78 FR 38949 - Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response

    Science.gov (United States)

    2013-06-28

    ... exposed to various forms of cyber attack. In some cases, attacks can be thwarted through the use of...-3383-01] Computer Security Incident Coordination (CSIC): Providing Timely Cyber Incident Response... systems will be successfully attacked. When a successful attack occurs, the job of a Computer Security...

  16. Multi-unit dosage formulations of theophylline for controlled release applications.

    Science.gov (United States)

    Uhumwangho, Michael U; Okor, Roland S

    2007-01-01

    The study was carried out to investigate the drug release profiles of multi-unit dosage formulations of theophylline consisting of both the fast and slow release components in a unit dose. The fast release component consisted of conventional granules of theophylline formed by mixing the drug powder with starch mucilage (20% w/v) while the slow release component consisted of wax granulations of theophylline formed by triturating the drug powder with a melted Carnauba wax (drug:wax ratio, 4:1). The granules were either filled into capsules or tabletted. In the study design, the drug release characteristics of the individual fast or slow release particles were first determined separately and then mixed in various proportions for the purpose of optimizing the drug release profiles. The evaluating parameters were the prompt release in the first 1 h (mp), the maximum release (m infinity) and the time to attain it (t infinity). Total drug content in each capsule or tablet was 300 mg and two of such were used in dissolution studies. The release kinetics and hence the release mechanism was confirmed by measuring the linear regression coefficient (R2 values) of the release data. The release kinetics was generally most consistent with the Higuchi square root of time relationship (R2 = 0.95). indicating a diffusion-controlled mechanism. The mp (mg) and t infinity (h) values for capsules and tablets of the conventional granules were (420 mg, 3 h) and (348 mg, 5 h), respectively, while for the capsules and tablets of the wax granulations mp and t infinity values were (228 mg, 9 h) and (156 mg, 12 h), respectively, indicating that a combination of wax granulation and tableting markedly retarded drug release. In the multi-unit dose formulations where the conventional and wax granulations were mixed in the ratios 2:1, 1:1 and 1:2 (conventional: matrix), the m infinity and t infinity values for the capsules were (378 mg, 6 h), (326 mg, 6 h) and (272 mg, 7 h), reSpectively. The

  17. Risk-informed assessment of radionuclide release from dissolution of spent nuclear fuel and high-level waste glass

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Tae M., E-mail: tae.ahn@nrc.gov

    2017-06-15

    Highlights: • Dissolution of HLW waste form was assessed with long-term risk informed approach. • The radionuclide release rate decreases with time from the initial release rate. • Fast release radionuclides can be dispersed with discrete container failure time. • Fast release radionuclides can be restricted by container opening area. • Dissolved radionuclides may be further sequestered by sorption or others means. - Abstract: This paper aims to detail the different parameters to be considered for use in an assessment of radionuclide release. The dissolution of spent nuclear fuel and high-level nuclear waste glass was considered for risk and performance insights in a generic disposal system for more than 100,000 years. The probabilistic performance assessment includes the waste form, container, geology, and hydrology. Based on the author’s previous extended work and data from the literature, this paper presents more detailed specific cases of (1) the time dependence of radionuclide release, (2) radionuclide release coupled with container failure (rate-limiting process), (3) radionuclide release through the opening area of the container and cladding, and (4) sequestration of radionuclides in the near field after container failure. These cases are better understood for risk and performance insights. The dissolved amount of waste form is not linear with time but is higher at first. The radionuclide release rate from waste form dissolution can be constrained by container failure time. The partial opening area of the container surface may decrease radionuclide release. Radionuclides sequestered by various chemical reactions in the near field of a failed container may become stable with time as the radiation level decreases with time.

  18. Fluoride-releasing restorative materials and secondary caries.

    Science.gov (United States)

    Hicks, John; Garcia-Godoy, Franklin; Donly, Kevin; Flaitz, Catherine

    2003-03-01

    Secondary caries is responsible for 60 percent of all replacement restorations in the typical dental practice. Risk factors for secondary caries are similar to those for primary caries development. Unfortunately, it is not possible to accurately predict which patients are at risk for restoration failure. During the past several decades, fluoride-releasing dental materials have become a part of the dentist's armamentarium. Considerable fluoride is released during the setting reaction and for periods up to eight years following restoration placement. This released fluoride is readily taken up by the cavosurface tooth structure, as well as the enamel and root surfaces adjacent to the restoration. Resistance against caries along the cavosurface and the adjacent smooth surface has been shown in both in vitro and in vivo studies. Fluoride-releasing dental materials provide for improved resistance against primary and secondary caries in coronal and root surfaces. Plaque and salivary fluoride levels are elevated to a level that facilitates remineralization. In addition, the fluoride released to dental plaque adversely affects the growth of lactobacilli and mutans streptococci by interference with bacterial enzyme systems. Fluoride recharging of these dental materials is readily achieved with fluoridated toothpastes, fluoride mouthrinses, and other sources of topical fluoride. This allows fluoride-releasing dental materials to act as intraoral fluoride reservoirs. The improvement in the properties of dental materials with the ability to release fluoride has improved dramatically in the past decade, and it is anticipated that in the near future the vast majority of restorative procedures will employ fluoride-releasing dental materials as bonding agents, cavity liners, luting agents, adhesives for orthodontic brackets, and definitive restoratives.

  19. Radionuclide release calculations for SAR-08

    International Nuclear Information System (INIS)

    Thomson, Gavin; Miller, Alex; Smith, Graham; Jackson, Duncan

    2008-04-01

    Following a review by the Swedish regulatory authorities of the post-closure safety assessment of the SFR 1 disposal facility for low and intermediate waste (L/ILW), SAFE, the SKB has prepared an updated assessment called SAR-08. This report describes the radionuclide release calculations that have been undertaken as part of SAR-08. The information, assumptions and data used in the calculations are reported and the results are presented. The calculations address issues raised in the regulatory review, but also take account of new information including revised inventory data. The scenarios considered include the main case of expected behaviour of the system, with variants; low probability releases, and so-called residual scenarios. Apart from these scenario uncertainties, data uncertainties have been examined using a probabilistic approach. Calculations have been made using the AMBER software. This allows all the component features of the assessment model to be included in one place. AMBER has been previously used to reproduce results the corresponding calculations in the SAFE assessment. It is also used in demonstration of the IAEA's near surface disposal assessment methodology ISAM and has been subject to very substantial verification tests and has been used in verifying other assessment codes. Results are presented as a function of time for the release of radionuclides from the near field, and then from the far field into the biosphere. Radiological impacts of the releases are reported elsewhere. Consideration is given to each radionuclide and to each component part of the repository. The releases from the entire repository are also presented. The peak releases rates are, for most scenarios, due to organic C-14. Other radionuclides which contribute to peak release rates include inorganic C-14, Ni-59 and Ni-63. (author)

  20. Radionuclide release calculations for SAR-08

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, Gavin; Miller, Alex; Smith, Graham; Jackson, Duncan (Enviros Consulting Ltd, Wolverhampton (United Kingdom))

    2008-04-15

    Following a review by the Swedish regulatory authorities of the post-closure safety assessment of the SFR 1 disposal facility for low and intermediate waste (L/ILW), SAFE, the SKB has prepared an updated assessment called SAR-08. This report describes the radionuclide release calculations that have been undertaken as part of SAR-08. The information, assumptions and data used in the calculations are reported and the results are presented. The calculations address issues raised in the regulatory review, but also take account of new information including revised inventory data. The scenarios considered include the main case of expected behaviour of the system, with variants; low probability releases, and so-called residual scenarios. Apart from these scenario uncertainties, data uncertainties have been examined using a probabilistic approach. Calculations have been made using the AMBER software. This allows all the component features of the assessment model to be included in one place. AMBER has been previously used to reproduce results the corresponding calculations in the SAFE assessment. It is also used in demonstration of the IAEA's near surface disposal assessment methodology ISAM and has been subject to very substantial verification tests and has been used in verifying other assessment codes. Results are presented as a function of time for the release of radionuclides from the near field, and then from the far field into the biosphere. Radiological impacts of the releases are reported elsewhere. Consideration is given to each radionuclide and to each component part of the repository. The releases from the entire repository are also presented. The peak releases rates are, for most scenarios, due to organic C-14. Other radionuclides which contribute to peak release rates include inorganic C-14, Ni-59 and Ni-63. (author)

  1. Accidental releases of radionuclides: a preliminary study of the consequences of land contamination

    International Nuclear Information System (INIS)

    Simmonds, J.R.; Haywood, S.M.; Linsley, G.S.

    1982-10-01

    The long term consequences of land contamination from accidental releases of activity from thermal reactors are examined. The radiological consequences are assessed using an analysis of the exposure of individuals and the population to ground deposits of the radionuclides released. The contribution of the different nuclides in the release by their various exposure routes to the irradiation of man are calculated as a function of time after release and the most radiologically important are identified. A preliminary assessment is made of off-site economic and social consequences of accidental releases by estimating the areas of land which would be affected by the introduction of countermeasures to control individual radiation exposure due to external irradiation from ground deposits (relocation of populations), and the intake of radionuclides contained in locally produced foodstuffs (restrictions on food production). The areas where administrative controls would be necessary decline in size with time after the release; estimates are made of this time-dependent behaviour using dynamic environmental transfer models. Finally, the collective doses saved by the introduction of countermeasures are estimated using population and agricultural distribution data for a rural location in the United Kingdom. (author)

  2. Tritium release from neutron irradiated beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Scaffidi-Argentina, F.; Werle, H. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reactortechnik

    1998-01-01

    One of the most important open issues related to beryllium for fusion applications refers to the kinetics of the tritium release as a function of neutron fluence and temperature. The EXOTIC-7 as well as the `Beryllium` experiments carried out in the HFR reactor in Petten are considered as the most detailed and significant tests for investigating the beryllium response under neutron irradiation. This paper reviews the present status of beryllium post-irradiation examinations performed at the Forschungszentrum Karlsruhe with samples from the above mentioned irradiation experiments, trying to elucidate the tritium release controlling processes. In agreement with previous studies it has been found that release starts at about 500-550degC and achieves a maximum at about 700-750degC. The observed release at about 500-550degC is probably due to tritium escaping from chemical traps, while the maximum release at about 700-750degC is due to tritium escaping from physical traps. The consequences of a direct contact between beryllium and ceramics during irradiation, causing tritium implanting in a surface layer of beryllium up to a depth of about 40 mm and leading to an additional inventory which is usually several times larger than the neutron-produced one, are also presented and the effects on the tritium release are discussed. (author)

  3. Correlation of recent fission product release data

    International Nuclear Information System (INIS)

    Kress, T.S.; Lorenz, R.A.; Nakamura, T.; Osborne, M.F.

    1989-01-01

    For the calculation of source terms associated with severe accidents, it is necessary to model the release of fission products from fuel as it heats and melts. Perhaps the most definitive model for fission product release is that of the FASTGRASS computer code developed at Argonne National Laboratory. There is persuasive evidence that these processes, as well as additional chemical and gas phase mass transport processes, are important in the release of fission products from fuel. Nevertheless, it has been found convenient to have simplified fission product release correlations that may not be as definitive as models like FASTGRASS but which attempt in some simple way to capture the essence of the mechanisms. One of the most widely used such correlation is called CORSOR-M which is the present fission product/aerosol release model used in the NRC Source Term Code Package. CORSOR has been criticized as having too much uncertainty in the calculated releases and as not accurately reproducing some experimental data. It is currently believed that these discrepancies between CORSOR and the more recent data have resulted because of the better time resolution of the more recent data compared to the data base that went into the CORSOR correlation. This document discusses a simple correlational model for use in connection with NUREG risk uncertainty exercises. 8 refs., 4 figs., 1 tab

  4. Tritium behavior intentionally released in the room

    International Nuclear Information System (INIS)

    Kobayashi, K.; Hayashi, T.; Iwai, Y.; Yamanishi, T.; Willms, R. S.; Carlson, R. V.

    2008-01-01

    To construct a fusion reactor with high safety and acceptability, it is necessary to establish and to ensure tritium safe handling technology. Tritium should be well-controlled not to be released to the environment excessively and to prevent workers from excess exposure. It is especially important to grasp tritium behavior in the final confinement area, such as the room and/or building. In order to obtain data for actual tritium behavior in a room and/or building, a series of intentional Tritium Release Experiments (TREs) were planned and carried out within a radiologically controlled area (main cell) at Tritium System Test Assembly (TSTA) in Los Alamos National Laboratory (LANL) under US-JAPAN collaboration program. These experiments were carried out three times. In these experiments, influence of a difference in the tritium release point and the amount of hydrogen isotope for the initial tritium behavior in the room were suggested. Tritium was released into the main cell at TSTA/LANL. The released tritium reached a uniform concentration about 30 - 40 minutes in all the experiments. The influence of the release point and the amount of hydrogen isotope were not found to be important in these experiments. The experimental results for the initial tritium behavior in the room were also simulated well by the modified three-dimensional eddy flow analysis code FLOW-3D. (authors)

  5. NAMMU (Release 6.1) for the Sun: installation and running

    International Nuclear Information System (INIS)

    Cliffe, K.A.

    1993-12-01

    NAMMU is a software package for modelling groundwater flow and transport in porous media. The package can be used to model steady-state and time-dependent behaviour, including unsaturated flow and the transport of heat and mass. An option is available for modelling radioactive decay and transport of chains of radionuclides. The software is based on an efficient implementation of the finite-element method that provides many options for modelling complex geological strata. This report describes how to install and run Release 6.1 of NAMMU on a Sun SparcStation using version 6.1.4 of the job submission script. (Author)

  6. Ultrasound stimulated release of gallic acid from chitin hydrogel matrix

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Huixin; Kobayashi, Takaomi, E-mail: takaomi@nagaokaut.ac.jp

    2017-06-01

    Ultrasound (US) stimulated drug release was examined in this study using a chitin hydrogel matrix loaded with gallic acid (GA), a drug used for wound healing and anticancer. Using phase inversion, GA-chitin hydrogels were prepared from chitin-dimethylacetamide (DMAc)/lithium chloride (LiCl) solution in the presence of GA, with 24 h exposure of the solution to water vapor. The GA release from the GA-chitin hydrogel was examined under different US powers of 0–30 W at 43 kHz. The effects of GA loading amounts in the hydrogels (0.54, 0.43, and 0.25 mg/cm{sup 3}) and chitin concentrations (0.1, 0.5, and 1 wt%) on the release behaviors were recorded under 43 kHz US exposure at 30 W. Results show that US accelerated the release efficiencies for all samples. Furthermore, the release efficiency increased concomitantly with increasing US power, GA loading amount, and decrease of the chitin concentration. The highest release rate of 0.74 μg/mL·min was obtained from 0.54 mg/cm{sup 3} of GA-loaded hydrogel fabricated from a 0.1 wt% chitin mixture solution under 43 kHz US exposure at 30 W: nine times higher than that of the sample without US exposure. The hydrogel viscoelasticity demonstrated that the US irradiation rigidified the material. FT-IR showed that US can break the hydrogen bonds in the GA-chitin hydrogels. - Highlights: • Ultrasound (US) stimulated Gallic acid (GA) release from chitin hydrogel was studied. • The release efficiency of GA from chitin hydrogel increased nine times when irradiated by 43 kHz US compared with the sample without US. • Generalized 2D correlation and deconvolution study of FT-IR showed that US could promote the GA release by breaking hydrogen bonds.

  7. Ultrasound stimulated release of gallic acid from chitin hydrogel matrix

    International Nuclear Information System (INIS)

    Jiang, Huixin; Kobayashi, Takaomi

    2017-01-01

    Ultrasound (US) stimulated drug release was examined in this study using a chitin hydrogel matrix loaded with gallic acid (GA), a drug used for wound healing and anticancer. Using phase inversion, GA-chitin hydrogels were prepared from chitin-dimethylacetamide (DMAc)/lithium chloride (LiCl) solution in the presence of GA, with 24 h exposure of the solution to water vapor. The GA release from the GA-chitin hydrogel was examined under different US powers of 0–30 W at 43 kHz. The effects of GA loading amounts in the hydrogels (0.54, 0.43, and 0.25 mg/cm 3 ) and chitin concentrations (0.1, 0.5, and 1 wt%) on the release behaviors were recorded under 43 kHz US exposure at 30 W. Results show that US accelerated the release efficiencies for all samples. Furthermore, the release efficiency increased concomitantly with increasing US power, GA loading amount, and decrease of the chitin concentration. The highest release rate of 0.74 μg/mL·min was obtained from 0.54 mg/cm 3 of GA-loaded hydrogel fabricated from a 0.1 wt% chitin mixture solution under 43 kHz US exposure at 30 W: nine times higher than that of the sample without US exposure. The hydrogel viscoelasticity demonstrated that the US irradiation rigidified the material. FT-IR showed that US can break the hydrogen bonds in the GA-chitin hydrogels. - Highlights: • Ultrasound (US) stimulated Gallic acid (GA) release from chitin hydrogel was studied. • The release efficiency of GA from chitin hydrogel increased nine times when irradiated by 43 kHz US compared with the sample without US. • Generalized 2D correlation and deconvolution study of FT-IR showed that US could promote the GA release by breaking hydrogen bonds.

  8. Calcium modified edible Canna (Canna edulis L) starch for controlled released matrix

    Science.gov (United States)

    Putri, A. P.; Ridwan, M.; Darmawan, T. A.; Darusman, F.; Gadri, A.

    2017-07-01

    Canna edulis L starch was modified with calcium chloride in order to form controlled released matrix. Present study aim to analyze modified starch characteristic. Four different formulation of ondansetron granules was used to provide dissolution profile of controlled released, two formula consisted of 15% and 30% modified starch, one formula utilized matrix reference standards and the last granules was negative control. Methocel-hydroxypropyl methyl cellulose was used as controlled released matrix reference standards in the third formula. Calcium starch was synthesized in the presence of sodium hydroxide to form gelatinized mass and calcium chloride as the cross linking agent. Physicochemical and dissolution properties of modified starch for controlled released application were investigated. Modified starch has higher swelling index, water solubility and compressibility index. Three of four different formulation of granules provide dissolution profile of controlled released. The profiles indicate granules which employed calcium Canna edulis L starch as matrix are able to resemble controlled drug released profile of matrix reference, however their bigger detain ability lead to lower bioavailability.

  9. Design of a new type of coating for the controlled release of heparin

    NARCIS (Netherlands)

    Hinrichs, W.L.J.; Hinrichs, W.L.J.; ten Hoopen, Hermina W.M.; Wissink, M.J.B.; Engbers, G.H.M.; Feijen, Jan

    1997-01-01

    Thrombus formation at the surface of blood contacting devices can be prevented by local release of heparin. Preferably, the release rate should be constant for prolonged periods of time. The minimum heparin release rate to achieve thromboresistance will be different for various applications and

  10. Kepler Data Release 25 Notes (Q0-Q17)

    Science.gov (United States)

    Mullally, Susan E.; Caldwell, Douglas A.; Barclay, Thomas Stewart; Barentsen, Geert; Clarke, Bruce Donald; Bryson, Stephen T.; Burke, Christopher James; Campbell, Jennifer Roseanna; Catanzarite, Joseph H.; Christiansen, Jessie; hide

    2016-01-01

    These Data Release Notes provide information specific to the current reprocessing and re-export of the Q0-Q17 data. The data products included in this data release include target pixel files, light curve files, FFIs,CBVs, ARP, Background, and Collateral files. This release marks the final processing of the Kepler Mission Data. See Tables 1 and 2 for a list of the reprocessed Kepler cadence data. See Table 3 for a list of the available FFIs. The Long Cadence Data, Short Cadence Data, and FFI data are documented in these data release notes. The ancillary files (i.e., cotrending basis vectors, artifact removal pixels, background, and collateral data) are described in the Archive Manual (Thompson et al., 2016).

  11. Localized sequence-specific release of a chemopreventive agent and an anticancer drug in a time-controllable manner to enhance therapeutic efficacy.

    Science.gov (United States)

    Pan, Wen-Yu; Lin, Kun-Ju; Huang, Chieh-Cheng; Chiang, Wei-Lun; Lin, Yu-Jung; Lin, Wei-Chih; Chuang, Er-Yuan; Chang, Yen; Sung, Hsing-Wen

    2016-09-01

    Combination chemotherapy with multiple drugs commonly requires several injections on various schedules, and the probability that the drug molecules reach the diseased tissues at the proper time and effective therapeutic concentrations is very low. This work elucidates an injectable co-delivery system that is based on cationic liposomes that are adsorbed on anionic hollow microspheres (Lipos-HMs) via electrostatic interaction, from which the localized sequence-specific release of a chemopreventive agent (1,25(OH)2D3) and an anticancer drug (doxorubicin; DOX) can be thermally driven in a time-controllable manner by an externally applied high-frequency magnetic field (HFMF). Lipos-HMs can greatly promote the accumulation of reactive oxygen species (ROS) in tumor cells by reducing their cytoplasmic expression of an antioxidant enzyme (superoxide dismutase) by 1,25(OH)2D3, increasing the susceptibility of cancer cells to the cytotoxic action of DOX. In nude mice that bear xenograft tumors, treatment with Lipos-HMs under exposure to HFMF effectively inhibits tumor growth and is the most effective therapeutic intervention among all the investigated. These empirical results demonstrate that the synergistic anticancer effects of sequential release of 1,25(OH)2D3 and DOX from the Lipos-HMs may have potential for maximizing DOX cytotoxicity, supporting more effective cancer treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. New trends in combined use of gonadotropin-releasing hormone antagonists with gonadotropins or pulsatile gonadotropin-releasing hormone in ovulation induction and assisted reproductive technologies.

    Science.gov (United States)

    Gordon, K; Danforth, D R; Williams, R F; Hodgen, G D

    1992-10-01

    The use of gonadotropin-releasing hormone agonists as adjunctive therapy with gonadotropins for ovulation induction in in vitro fertilization and other assisted reproductive technologies has become common clinical practice. With the recent advent of potent gonadotropin-releasing hormone antagonists free from the marked histamine-release effects that stymied earlier compounds, an attractive alternative method may be available. We have established the feasibility of combining gonadotropin-releasing hormone antagonist-induced inhibition of endogenous gonadotropins with exogenous gonadotropin therapy for ovulation induction in a nonhuman primate model. Here, the principal benefits to be gained from using the gonadotropin-releasing hormone antagonist rather than the gonadotropin-releasing hormone agonist are the immediate inhibition of pituitary gonadotropin secretion without the "flare effect," which brings greater safety and convenience for patients and the medical team and saves time and money. We have also recently demonstrated the feasibility of combining gonadotropin-releasing hormone antagonist with pulsatile gonadotropin-releasing hormone therapy for the controlled restoration of gonadotropin secretion and gonadal steroidogenesis culminating in apparently normal (singleton) ovulatory cycles. This is feasible only with gonadotropin-releasing hormone antagonists because, unlike gonadotropin-releasing hormone agonists, they achieve control of the pituitary-ovarian axis without down regulation of the gonadotropin-releasing hormone receptor system. This capacity to override gonadotropin-releasing hormone antagonist-induced suppression of pituitary-ovarian function may allow new treatment modalities to be employed for women who suffer from chronic hyperandrogenemia with polycystic ovarian disease.

  13. Release of silver nanoparticles from outdoor facades

    International Nuclear Information System (INIS)

    Kaegi, Ralf; Sinnet, Brian; Zuleeg, Steffen; Hagendorfer, Harald; Mueller, Elisabeth; Vonbank, Roger; Boller, Markus; Burkhardt, Michael

    2010-01-01

    In this study we investigate the release of metallic silver nanoparticles (Ag-NP) from paints used for outdoor applications. A facade panel mounted on a model house was exposed to ambient weather conditions over a period of one year. The runoff volume of individual rain events was determined and the silver and titanium concentrations of 36 out of 65 runoff events were measured. Selected samples were prepared for electron microscopic analysis. A strong leaching of the Ag-NP was observed during the initial runoff events with a maximum concentration of 145 μ Ag/l. After a period of one year, more than 30% of the Ag-NP were released to the environment. Particles were mostly 2 S. - We provide direct evidence for the release of silver nanoparticles from exterior paints to the aquatic environment.

  14. Altered elementary calcium release events and enhanced calcium release by thymol in rat skeletal muscle.

    Science.gov (United States)

    Szentesi, Péter; Szappanos, Henrietta; Szegedi, Csaba; Gönczi, Monika; Jona, István; Cseri, Julianna; Kovács, László; Csernoch, László

    2004-03-01

    The effects of thymol on steps of excitation-contraction coupling were studied on fast-twitch muscles of rodents. Thymol was found to increase the depolarization-induced release of calcium from the sarcoplasmic reticulum, which could not be attributed to a decreased calcium-dependent inactivation of calcium release channels/ryanodine receptors or altered intramembrane charge movement, but rather to a more efficient coupling of depolarization to channel opening. Thymol increased ryanodine binding to heavy sarcoplasmic reticulum vesicles, with a half-activating concentration of 144 micro M and a Hill coefficient of 1.89, and the open probability of the isolated and reconstituted ryanodine receptors, from 0.09 +/- 0.03 to 0.22 +/- 0.04 at 30 micro M. At higher concentrations the drug induced long-lasting open events on a full conducting state. Elementary calcium release events imaged using laser scanning confocal microscopy in the line-scan mode were reduced in size, 0.92 +/- 0.01 vs. 0.70 +/- 0.01, but increased in duration, 56 +/- 1 vs. 79 +/- 1 ms, by 30 micro M thymol, with an increase in the relative proportion of lone embers. Higher concentrations favored long events, resembling embers in control, with duration often exceeding 500 ms. These findings provide direct experimental evidence that the opening of a single release channel will generate an ember, rather than a spark, in mammalian skeletal muscle.

  15. Percutaneous carpal tunnel release compared with mini-open release using ultrasonographic guidance for both techniques.

    Science.gov (United States)

    Nakamichi, Ken-ichi; Tachibana, Shintaro; Yamamoto, Seizo; Ida, Masayoshi

    2010-03-01

    To compare the outcomes of percutaneous carpal tunnel release (PCTR) and mini-open carpal tunnel release (mini-OCTR) using ultrasonographic guidance for both techniques. We included 74 hands of 65 women with idiopathic carpal tunnel syndrome (age, 52-71 y; mean, 58 y). Thirty-five hands of 29 women had the PCTR (release with a device consisting of an angled blade, guide, and holder, along a line midway between the median nerve and ulnar artery (safe line) under ultrasonography (incision, 4 mm), and 39 hands of 36 women had the mini-OCTR (release along the safe line, distally under direct vision (incision, 1-1.5 cm) and proximally under ultrasonography, using a device consisting of a basket punch and outer tube. Assessments at 3, 6, 13, 26, 52, and 104 weeks showed no significant differences in neurologic recovery between the groups (p > .05). The PCTR group had significantly less pain, greater grip and key-pinch strengths, and better satisfaction scores at 3 and 6 weeks (p < .05), and less scar sensitivity at 3, 6, and 13 weeks (p < .05). There were no complications. The PCTR provides the same neurologic recovery as does the mini-OCTR. The former leads to less postoperative morbidity and earlier functional return and achievement of satisfaction. Therapeutic III. Copyright 2010. Published by Elsevier Inc.

  16. Formulation and evaluation of controlled-release of telmisartan microspheres: In vitro/in vivo study

    Directory of Open Access Journals (Sweden)

    Praveen Kumar Gaur

    2014-12-01

    Full Text Available The aim of this work was to design a controlled-release drug-delivery system for the angiotensin-II receptor antagonist drug telmisartan. Telmisartan was encapsulated with different EUDRAGIT polymers by an emulsion solvent evaporation technique and the physicochemical properties of the formulations were characterized. Using a solvent evaporation method, white spherical microspheres with particle sizes of 629.9–792.1 μm were produced. The in vitro drug release was studied in three different pH media (pH 1.2 for 2 hours, pH 6.8 for 4 hours, and pH 7.4 for 18 hours. The formulations were then evaluated for their pharmacokinetic parameters. The entrapment efficiency of these microspheres was between 58.6% and 90.56%. The obtained microspheres showed good flow properties, which were evaluated in terms of angle of repose (15.29–26.32, bulk and tapped densities (0.37–0.53 and 0.43–0.64, respectively, Carr indices and Hausner ratio (12.94–19.14% and 1.14–1.23, respectively. No drug release was observed in the simulated gastric medium up to 2 hours; however, a change in pH from 1.2 to 6.8 increased the drug release. At pH 7.4, formulations with EUDRAGIT RS 100 showed a steady drug release. The microsphere formulation TMRS-3 (i.e., microspheres containing 2-mg telmisartan gave the highest Cmax value (6.8641 μg/mL at 6 hours, which was three times higher than Cmax for telmisartan oral suspension (TOS. Correspondingly, the area under the curve for TMRS-3 was 8.5 times higher than TOS. Particle size and drug release depended on the nature and content of polymer used. The drug release mechanism of the TMRS-3 formulation can be explained using the Higuchi model. The controlled release of drug from TMRS-3 also provides for higher plasma drug content and improved bioavailability.

  17. Preliminary evaluation of the potential for plutonium release from burial grounds at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Wheeler, M.L.; Smith, W.J.; Gallegos, A.F.

    1977-02-01

    An analysis was made of a number of natural phenomena which could result in the release of plutonium from radioactive wastes buried at the Los Alamos Scientific Laboratory (LASL). Background information concerning the history and practice of radioactive waste disposal at LASL is provided. The potential impact of buried radioactive wastes on the environment is addressed through the mechanisms and rates by which the radionuclides can enter the environment. Only mechanisms independent of human activity are considered. They are divided into two classes, acute and chronic. The acute release mechanisms considered are earthquakes, meteorite impacts, and tornadoes. These have been typified by low occurrence probabilities (10 -6 to 10 -7 /yr). The chronic mechanisms that have been considered are release through uptake by plant roots, exposure by soil erosion, and transport by soil water. The rates of these processes are low, but may result in radionuclide release over long time periods. The analysis of uptake by plant roots was made using an environmental model currently under development; the model is discussed in some detail

  18. Nuclear magnetic resonance provides a quantitative description of protein conformational flexibility on physiologically important time scales.

    Science.gov (United States)

    Salmon, Loïc; Bouvignies, Guillaume; Markwick, Phineus; Blackledge, Martin

    2011-04-12

    A complete description of biomolecular activity requires an understanding of the nature and the role of protein conformational dynamics. In recent years, novel nuclear magnetic resonance-based techniques that provide hitherto inaccessible detail concerning biomolecular motions occurring on physiologically important time scales have emerged. Residual dipolar couplings (RDCs) provide precise information about time- and ensemble-averaged structural and dynamic processes with correlation times up to the millisecond and thereby encode key information for understanding biological activity. In this review, we present the application of two very different approaches to the quantitative description of protein motion using RDCs. The first is purely analytical, describing backbone dynamics in terms of diffusive motions of each peptide plane, using extensive statistical analysis to validate the proposed dynamic modes. The second is based on restraint-free accelerated molecular dynamics simulation, providing statistically sampled free energy-weighted ensembles that describe conformational fluctuations occurring on time scales from pico- to milliseconds, at atomic resolution. Remarkably, the results from these two approaches converge closely in terms of distribution and absolute amplitude of motions, suggesting that this kind of combination of analytical and numerical models is now capable of providing a unified description of protein conformational dynamics in solution.

  19. EPICS release 3.11.6 specific documentation -- Release notes for EPICS 3.11.6

    International Nuclear Information System (INIS)

    1994-01-01

    These notes cover the following: (1) directions for switching to production APS release R3.11.6; (2) unbundling of channel access clients; (3) access security; (4) channel access additions; synchronous time support; and (5) description of major differences between R3.11.3 and R3.11.6 Also included is a list of new and/or updated documentation for the program

  20. The Atmospheric Release Advisory Capability Site Workstation System

    International Nuclear Information System (INIS)

    Foster, K.T.; Sumikawa, D.A.; Foster, C.S.; Baskett, R.L.

    1993-01-01

    The Atmospheric Release Advisory Capability (ARAC) is a centralized emergency response service that assesses the consequences that may result from an atmospheric release of toxic material. ARAC was developed by the Lawrence Livermore National Laboratory (LLNL) for the Departments of Energy (DOE) and Defense (DOD) and responds principally to radiological accidents. ARAC provides radiological health and safety guidance to decision makers in the form of computer-generated estimates of the effects of an actual, or potential release of radioactive material into the atmosphere. Upon receipt of the release scenario, the ARAC assessment staff extracts meteorological, topographic, and geographic data from resident world-wide databases for use in complex, three-dimensional transport and diffusion models. These dispersion models generate air concentration (or dose) and ground deposition contour plots showing estimates of the contamination patterns produced as the toxic material is carried by the prevailing winds. To facilitate the ARAC response to a release from specific DOE and DOD sites and to provide these sites with a local emergency response tool, a remote Site Workstation System (SWS) is being placed at various ARAC-supported facilities across the country.. This SWS replaces the existing antiquated ARAC Site System now installed at many of these sites. The new system gives users access to complex atmospheric dispersion models that may be run either by the ARAC staff at LLNL, or (in a later phase of the system) by site personnel using the computational resources of the SWS. Supporting this primary function are a variety of SWS-resident supplemental capabilities that include meteorological data acquisition, manipulation of release-specific databases, computer-based communications, and the use of a simpler Gaussian trajectory puff model that is based on Environmental Protection Agency's INPUFF code

  1. Single- and multiple-dose pharmacokinetics of biphasic immediate-release/extended-release hydrocodone bitartrate/acetaminophen (MNK-155 compared with immediate-release hydrocodone bitartrate/ibuprofen and immediate-release tramadol HCl/acetaminophen

    Directory of Open Access Journals (Sweden)

    Devarakonda K

    2015-09-01

    Full Text Available Krishna Devarakonda,1 Kenneth Kostenbader,2 Michael J Giuliani,3 Jim L Young41Department of Clinical Pharmacology, Mallinckrodt Pharmaceuticals, 2Mallinckrodt Pharmaceuticals, 3Research and Development, Mallinckrodt Pharmaceuticals, 4Department of Clinical Affairs and Program Management, Mallinckrodt Pharmaceuticals, Hazelwood, MO, USAObjective: To characterize the single-dose and steady-state pharmacokinetics (PK of biphasic immediate-release/extended-release hydrocodone bitartrate/acetaminophen (IR/ER HB/APAP, IR HB/ibuprofen, and IR tramadol HCl/APAP.Methods: In this single-center, open-label, randomized, four-period crossover study, healthy participants received four treatments under fasted conditions: 1 a single dose of two IR/ER HB/APAP 7.5/325 mg tablets (15/650 mg total dose on day 1, followed by two tablets every 12 hours (q12h beginning on day 3; 2 a single dose of IR HB/ibuprofen 15/400 mg (divided as one 7.5/200 mg tablet at hour 0 and 6, followed by one tablet every 6 hours (q6h beginning on day 3; 3 a single dose of IR tramadol HCl/APAP 75/650 mg (divided as one 37.5/325 mg tablet at hour 0 and 6, followed by one tablet q6h beginning on day 3; and 4 a single dose of three IR/ER HB/APAP 7.5/325 mg tablets (22.5/975 mg total dose on day 1, a three-tablet initial dose at 48 hours followed by two-tablet doses q12h beginning on day 3. Hydrocodone and APAP single-dose and steady-state PK were assessed. Adverse events were monitored.Results: The PK analysis was carried out on 29 of 48 enrolled participants who completed all treatment periods. Single-dose hydrocodone exposure was similar for IR/ER HB/APAP 22.5/975 mg and IR HB/ibuprofen 15/400 mg; time to maximum observed plasma concentration was shorter and half-life was longer for IR/ER HB/APAP (22.5/975 mg and 15/650 mg vs IR HB/ibuprofen. Single-dose APAP exposure was similar for IR/ER HB/APAP 15/650 mg and IR tramadol HCl/APAP 75/650 mg. Steady-state hydrocodone and APAP exposures

  2. Mathematical modeling of radionuclide release through a borehole in a radioactive waste repository

    International Nuclear Information System (INIS)

    Choi, Heui Joo

    1996-02-01

    The effects of inadvertent human intrusion as a form of direct drilling into a radioactive waste repository are discussed in this thesis. It has been mentioned that the inadvertent direct drilling into the repository could provide a release pathway for radionuclides even with its low occurrence probability. The following analyses are carried out regarding the problem. The maximum concentration in a water-filled borehole penetrating a repository is computed with a simple geometry. The modeling is based upon the assumption of the diffusive mass transfer in the waste forms and the complete mixing in the borehole. It is shown that the maximum concentrations of six radionuclides in the borehole could exceed the Maximum Permissible Concentration. Also, the diffusive mass transport in a water-filled borehole is investigated with a solubility-limited boundary condition. An analytic solution is derived for this case. Results show that the diffusive mass transport is fast enough to justify the assumption of the complete mixing compared with the considered time span. The axial diffusive mass transport along a water-filled borehole is modeled to compute the release rate taking account of the rock matrix diffusion. The results show that the release of short-lived radionuclides are negligible due to the low concentration gradient in early time and the rock matrix diffusion. The release rates of four long-lived radionuclides are computed. It is also shown that the model developed could be applied to a borehole at a non-cylindrically shaped repository and the off-center drilling of a cylindrical repository. The release rates of long-lived nuclides through a porous material-filled borehole are computed. The results show that the release of all the long-lived nuclides is negligible up to half million years in the case that the borehole is filled with the porous material. The radiological effects of the nuclides released through the borehole penetrating the repository are computed

  3. Atmospheric Release Advisory Capability

    International Nuclear Information System (INIS)

    Dickerson, M.H.; Gudiksen, P.H.; Sullivan, T.J.

    1983-02-01

    The Atmospheric Release Advisory Capability (ARAC) project is a Department of Energy (DOE) sponsored real-time emergency response service available for use by both federal and state agencies in case of a potential or actual atmospheric release of nuclear material. The project, initiated in 1972, is currently evolving from the research and development phase to full operation. Plans are underway to expand the existing capability to continuous operation by 1984 and to establish a National ARAC Center (NARAC) by 1988. This report describes the ARAC system, its utilization during the past two years, and plans for its expansion during the next five to six years. An integral part of this expansion is due to a very important and crucial effort sponsored by the Defense Nuclear Agency to extend the ARAC service to approximately 45 Department of Defense (DOD) sites throughout the continental US over the next three years

  4. A Web Based Framework for Pre-release Testing of Mobile Applications

    Directory of Open Access Journals (Sweden)

    Hamdy Abeer

    2016-01-01

    Full Text Available Mobile applications are becoming an integral part of daily life and of business’s marketing plan. They are helpful in promoting for the business, attracting and retaining customers. Software testing is vital to ensure the delivery of high quality mobile applications that could be accessed across different platforms and meet business and technical requirements. This paper proposes a web based tool, namely Pons, for the distribution of pre-release mobile applications for the purpose of manual testing. Pons facilities building, running, and manually testing Android applications directly in the browser. It gets the developers and end users engaged in testing the applications in one place, alleviates the tester’s burden of installing and maintaining testing environments, and provides a platform for developers to rapidly iterate on the software and integrate changes over time. Thus, it speeds up the pre-release testing process, reduces its cost and increases customer satisfaction.

  5. Study of applying the Atmospheric Release Advisory Capability to nuclear power plants

    International Nuclear Information System (INIS)

    Orphan, R.C.

    1978-06-01

    Each utility licensee for a nuclear power reactor is required to minimize the adverse effects from an accidental radionuclide release into the atmosphere. In the past the ability to forecast quantitatively the extent of the hazard from such a release has been limited. Now powerful atmospheric modeling techniques are available to assist nuclear reactor site officials with greatly improved assessments. Lawrence Livermore Laboratory (LLL) has developed a prototype system called the Atmospheric Release Advisory Capability (ARAC) which is designed to integrate the modeling with advanced sensors, data handling techniques, and weather data in order to provide timely, usable advisories to the site officials. The purpose of this project is to examine the ways and means of adapting ARAC for application to many nuclear power reactors widely dispersed across the nation. The project will emphasize the management aspects, including government-industry relationships, technology transfer, organizational structure, staffing, implementing procedures, and costs. Benefits and costs for several alternative systems will be compared. The results will be reviewed and evaluated by the management and staff of the ARAC project at LLL and also by selected staff members of the sponsoring government agency

  6. Deglacial climate modulated by the storage and release of Arctic sea ice

    Science.gov (United States)

    Condron, A.; Coletti, A. J.; Bradley, R. S.

    2017-12-01

    Periods of abrupt climate cooling during the last deglaciation (20 - 8 kyr ago) are often attributed to glacial outburst floods slowing the Atlantic meridional overturning circulation (AMOC). Here, we present results from a series of climate model simulations showing that the episodic break-up and mobilization of thick, perennial, Arctic sea ice during this time would have released considerable volumes of freshwater directly to the Nordic Seas, where processes regulating large-scale climate occur. Massive sea ice export events to the North Atlantic are generated whenever the transport of sea ice is enhanced, either by changes in atmospheric circulation, rising sea level submerging the Bering land bridge, or glacial outburst floods draining into the Arctic Ocean from the Mackenzie River. We find that the volumes of freshwater released to the Nordic Seas are similar to, or larger than, those estimated to have come from terrestrial outburst floods, including the discharge at the onset of the Younger Dryas. Our results provide the first evidence that the storage and release of Arctic sea ice helped drive deglacial climate change by modulating the strength of the AMOC.

  7. Manual of dose evaluation from atmospheric releases

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Abrol, V [Health Physics Division, Bhabha Atomic Research Centre, Bombay (India)

    1978-07-01

    The problem of dose evaluation from atmospheric releases is reduced to simple arithmetic by giving tables of concentrations and time integrated concentrations for instantaneous plumes and long time (1 year), sector averaged plumes for distances upto 10 km, effective release heights of upto 200 m and the six Pasquill stability classes. Correction factors for decay, depletion due to deposition and rainout are also given. Inhalation doses, immersion doses and contamination levels can be obtained from these by using multiplicative factors tabulated for various isotopes of significance. Tables of external gamma doses from plume are given separately for various gamma energies. Tables are also given to evaluate external beta and gamma dose rates from contaminated surfaces. The manual also discusses the basic diffusion model relevant to the problem. (author)

  8. Sintering of wax for controlling release from pellets.

    Science.gov (United States)

    Singh, Reena; Poddar, S S; Chivate, Amit

    2007-09-14

    The purpose of the present study was to investigate incorporation of hydrophobic (ie, waxy) material into pellets using a thermal sintering technique and to evaluate the pellets in vitro for controlled release. Pellets prepared by extrusion-spheronization technology were formulated with a water-soluble drug, microcrystalline cellulose, and carnauba wax. Powdered carnauba wax (4%-20%) prepared by grinding or by emulsification was studied with an attempt to retard the drug release. The inclusion of ground or emulsified carnauba wax did not sustain the release of theophylline for more than 3 hours. Matrix pellets of theophylline prepared with various concentrations of carnauba wax were sintered thermally at various times and temperatures. In vitro drug release profiles indicated an increase in drug release retardation with increasing carnauba wax concentration. Pellets prepared with ground wax showed a higher standard deviation than did those prepared with emulsified wax. There was incomplete release at the end of 12 hours for pellets prepared with 20% ground or emulsified wax. The sintering temperature and duration were optimized to allow for a sustained release lasting at least 12 hours. The optimized temperature and duration were found to be 100 degrees C and 140 seconds, respectively. The sintered pellets had a higher hydrophobicity than did the unsintered pellets. Scanning electron micrographs indicated that the carnauba wax moved internally, thereby increasing the surface area of wax within the pellets.

  9. Xyce parallel electronic simulator release notes.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R; Hoekstra, Robert John; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Thornquist, Heidi K.; Rankin, Eric Lamont; Coffey, Todd S; Pawlowski, Roger P; Santarelli, Keith R.

    2010-05-01

    The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. Specific requirements include, among others, the ability to solve extremely large circuit problems by supporting large-scale parallel computing platforms, improved numerical performance and object-oriented code design and implementation. The Xyce release notes describe: Hardware and software requirements New features and enhancements Any defects fixed since the last release Current known defects and defect workarounds For up-to-date information not available at the time these notes were produced, please visit the Xyce web page at http://www.cs.sandia.gov/xyce.

  10. Hydraulic running and release tool with mechanical emergency release

    International Nuclear Information System (INIS)

    Baker, S.F.

    1991-01-01

    This patent describes a setting tool for connection in a well string to position a tubular member in a well bore. It comprises: a mandrel adapted to be connected to the well string; an outer sleeve surrounding the mandrel and releasably secured thereto; a latch nut releasably connected to the outer sleeve; piston means sealingly engaging the mandrel; shear means releasably securing the piston to the latch nut to maintain the latch nut releasably connected to the tubular member; the mandrel having port means for conducting fluid pressure from the well string to release the piston means from and the latch nut; cooperating engageable surfaces on the piston and latch nut to reengage them together after the piston moves a predetermined longitudinal distance relative to the latch nut; and additional cooperating engageable surfaces on the latch nut and the outer sleeve which are engageable when the piston and engaged latch nut are moved a predetermined additional longitudinal distance by fluid pressure to secure the engaged piston and latch nut with the outer sleeve for retrieval along with the mandrel from the well bore

  11. Study of the components of evacuation times

    International Nuclear Information System (INIS)

    Mills, G.S.; Neuhauser, K.S.; Smith, J.D.

    1997-11-01

    The magnitudes of accident dose risks calculated by the RADTRAN code depend directly on the time span between an accidental release and evacuation of the affected area surrounding potential radionuclide releases. In a previous study of truck and rail transportation accidents, and other incidents requiring evacuations, a lognormal distribution of evacuation times (time span from decision to evacuate until complete) was developed, which provided a better model for this parameter than the practice of using a highly conservative value of 24 hours. However, the distribution did not account for time required for responders to arrive on the scene, to evaluate the hazards to surrounding population and to initiate an evacuation. Data from US Department of Transportation (DOT) accident statistics have been collected and their distribution functions determined. The separate distribution functions were combined into a single, comprehensive distribution which may be sampled to supply values of the RADTRAN input parameter, EVACUATION. A sample RADTRAN calculation illustrating the effect on risks of using the distribution versus the original (24 hour), conservative point-estimate are also presented

  12. Study of the components of evacuation times

    International Nuclear Information System (INIS)

    Mills, G.S.; Neuhauser, K.S.; Smith, J.D.

    1998-01-01

    The magnitudes of accident dose-risks calculated by the RADTRAN code depend directly on the time span between an accidental release and evacuation of the affected area surrounding potential radionuclide releases. In a previous study of truck and rail transportation accidents, and other incidents requiring evacuations (Mills et al., 1995) a lognormal distribution of evacuation times (time span from decision to evacuate until complete) was developed, which provided a better model for this parameter than the practice of using a highly conservative value of 24 hours. However, the distribution did not account for time required for responders to arrive on the scene, to evaluate the hazards to surrounding population and to initiate an evacuation. Data from U.S. Department of Transportation (DOT) accident statistics have been collected and their distribution functions determined. The separate distribution functions were combined into a single, comprehensive distribution which may be sampled to supply values of the RADTRAN input parameter, EVACUATION. A sample RADTRAN calculation illustrating the effect on risks of using the distribution versus the original (24 hours), conservative point-estimate are also presented. (authors)

  13. Determination of metal ions released by stainless steel arch bar into bio-fluids

    Directory of Open Access Journals (Sweden)

    Lori A. Joseph

    2009-04-01

    Full Text Available The amounts of cobalt, iron, manganese, nickel and chromium ions released from new and reused stainless steel arch bar used for maxillomandibular fixation was determined in Hank’s solutions of different hydrogen and chloride ions concentrations, whole blood serum and phosphate buffered saline (PBS in vitro, over a six-week immersion time at 37 oC, by atomic absorption spectrophotometry. The corrosion levels of the wires due to effects of media and incubation times in the bio-fluids were compared by Duncan’s two-way ANOVA (P less than 0.05. Pearson’s correlation was used in establishing relationship in the amounts of metal ions released by new and reused arch bars. The study indicated that the reused wires released more ions than new ones at all time points. The variation of pH and chloride ions of the bio-fluids had a significant effect on the amount of Ni, Mn and Cr ions released. Ageing prior use of arch bars significantly increased Ni ions released into the bio-fluids.

  14. Correlative scanning-transmission electron microscopy reveals that a chimeric flavivirus is released as individual particles in secretory vesicles.

    Directory of Open Access Journals (Sweden)

    Julien Burlaud-Gaillard

    Full Text Available The intracellular morphogenesis of flaviviruses has been well described, but flavivirus release from the host cell remains poorly documented. We took advantage of the optimized production of an attenuated chimeric yellow fever/dengue virus for vaccine purposes to study this phenomenon by microscopic approaches. Scanning electron microscopy (SEM showed the release of numerous viral particles at the cell surface through a short-lived process. For transmission electron microscopy (TEM studies of the intracellular ultrastructure of the small number of cells releasing viral particles at a given time, we developed a new correlative microscopy method: CSEMTEM (for correlative scanning electron microscopy - transmission electron microscopy. CSEMTEM analysis suggested that chimeric flavivirus particles were released as individual particles, in small exocytosis vesicles, via a regulated secretory pathway. Our morphological findings provide new insight into interactions between flaviviruses and cells and demonstrate that CSEMTEM is a useful new method, complementary to SEM observations of biological events by intracellular TEM investigations.

  15. Controlled release from aspirin based linear biodegradable poly(anhydride esters) for anti-inflammatory activity.

    Science.gov (United States)

    Dasgupta, Queeny; Movva, Sahitya; Chatterjee, Kaushik; Madras, Giridhar

    2017-08-07

    This work reports the synthesis of a novel, aspirin-loaded, linear poly (anhydride ester) and provides mechanistic insights into the release of aspirin from this polymer for anti-inflammatory activity. As compared to conventional drug delivery systems that rely on diffusion based release, incorporation of bioactives in the polymer backbone is challenging and high loading is difficult to achieve. In the present study, we exploit the pentafunctional sugar alcohol (xylitol) to provide sites for drug (aspirin) attachment at its non-terminal OH groups. The terminal OH groups are polymerized with a diacid anhydride. The hydrolysis of the anhydride and ester bonds under physiological conditions release aspirin from the matrix. The resulting poly(anhydride ester) has high drug loading (53%) and displays controlled release kinetics of aspirin. The polymer releases 8.5 % and 20%, of the loaded drug in one and four weeks, respectively and has a release rate constant of 0.0035h -0.61 . The release rate is suitable for its use as an anti-inflammatory agent without being cytotoxic. The polymer exhibits good cytocompatibility and anti-inflammatory properties and may find applications as injectable or as an implantable bioactive material. The physical insights into the release mechanism can provide development of other drug loaded polymers. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Formulation of Dipyridamole Sustained Release Tablet Using Floating System

    Directory of Open Access Journals (Sweden)

    Lenny Mauilida Valentina

    2011-06-01

    Full Text Available Dipyridamole is a drug for prevention of postoperative thromboembolic complication of heart valve replacement and long term therapy of angina pectoris will be well absorbed in stomach. To maintain therapeutic plasma concentration in long time and to increase bioavalaibility is needed a sustained release dosage form having the long residence time in the stomach. The objective of this research was to make floating sustained release tablet of dipyridamole conforming to the requirement that was set up by dipyridamol therapeutic concentration. Tablets were made by wet granulation method using aquadest as a liquid binder, HPMC K4M, Ac-di-sol, Avicel PH 102, talk, and Mg stearat. Dissolution assay was carried out using type 2 release tester at rotation speed of 50 rpm in medium 900 mL HCl 0.1 N at 37 ± 0.5 °C for 8 hours. The formulation containing of 50 mg dipirydamole, HPMC K4M (30%, Ac-di-sol (20%, Avicel PH 102 (37%, talk (2%, and Mg stearat (1% released 59.61 ± 6.73% and 89.34 ± 5.87% of dipyridamole respectively after 4 and 8 hours that conformed to the requirement.

  17. To bind or not to bind? Different temporal binding effects from voluntary pressing and releasing actions.

    Science.gov (United States)

    Zhao, Ke; Chen, Yu-Hsin; Yan, Wen-Jing; Fu, Xiaolan

    2013-01-01

    Binding effect refers to the perceptual attraction between an action and an outcome leading to a subjective compression of time. Most studies investigating binding effects exclusively employ the "pressing" action without exploring other types of actions. The present study addresses this issue by introducing another action, releasing action or the voluntary lifting of the finger/wrist, to investigate the differences between voluntary pressing and releasing actions. Results reveal that releasing actions led to robust yet short-lived temporal binding effects, whereas pressing condition had steady temporal binding effects up to super-seconds. The two actions also differ in sensitivity to changes in temporal contiguity and contingency, which could be attributed to the difference in awareness of action. Extending upon current models of "willed action," our results provide insights from a temporal point of view and support the concept of a dual system consisting of predictive motor control and top-down mechanisms.

  18. Fission gas release of MOX with heterogeneous structure

    International Nuclear Information System (INIS)

    Nakae, N.; Akiyama, H.; Kamimura, K; Delville, R.; Jutier, F.; Verwerft, M.; Miura, H.; Baba, T.

    2015-01-01

    It is very useful for fuel integrity evaluation to accumulate knowledge base on fuel behavior of uranium and plutonium mixed oxide (MOX) fuel used in light water reactors (LWRs). Fission gas release is one of fuel behaviors which have an impact on fuel integrity evaluation. Fission gas release behavior of MOX fuels having heterogeneous structure is focused in this study. MOX fuel rods with a heterogeneous fuel microstructure were irradiated in Halden reactor (IFA-702) and the BR-3/BR-2 CALLISTO Loop (CHIPS program). The 85 Kr gamma spectrometry measurements were carried out in specific cycles in order to examine the concerned LHR (Linear Heat Rate) for fission gas release in the CHIPS program. The concerned LHR is defined in this paper to be the LHR at which a certain additional fission gas release thermally occurs. Post-irradiation examination was performed to understand the fission gas release behavior in connection with the pellet microstructure. The followings conclusions can be made from this study. First, the concerned LHR for fission gas release is estimated to be in the range of 20-23 kW/m with burnup over 37 GWd/tM. It is moreover guessed that the concerned LHR for fission gas release tends to decrease with increasing burnup. Secondly It is observed that FGR (fission gas release rate) is positively correlated with LHR when the LHR exceeds the concerned value. Thirdly, when burnup dependence of fission gas release is discussed, effective burnup should be taken into account. The effective burnup is defined as the burnup at which the LHR should be exceed the concerned value at the last time during all the irradiation period. And fourthly, it appears that FGR inside Pu spots is higher than outside and that retained (not released) fission gases mainly exist in the fission gas bubbles. Since fission gases in bubbles are considered to be easily released during fuel temperature increase, this information is very important to estimate fission gas release behavior

  19. Development of Bilayer Tablets with Modified Release of Selected Incompatible Drugs.

    Science.gov (United States)

    Dhiman, Neha; Awasthi, Rajendra; Jindal, Shammy; Khatri, Smriti; Dua, Kamal

    2016-01-01

    The oral route is considered to be the most convenient and commonly-employed route for drug delivery. When two incompatible drugs need to be administered at the same time and in a single formulation, bilayer tablets are the most appropriate dosage form to administer such incompatible drugs in a single dose. The aim of the present investigation was to develop bilayered tablets of two incompatible drugs; telmisartan and simvastatin. The bilayer tablets were prepared containing telmisartan in a conventional release layer using croscarmellose sodium as a super disintegrant and simvastatin in a slow-release layer using HPMC K15M, Carbopol 934P and PVP K 30 as matrix forming polymers. The tablets were evaluated for various physical properties, drug-excipient interactions using FTIR spectroscopy and in vitro drug release using 0.1M HCl (pH 1.2) for the first hour and phosphate buffer (pH 6.8) for the remaining period of time. The release kinetics of simvastatin from the slow release layer were evaluated using the zero order, first order, Higuchi equation and Peppas equation. All the physical parameters (such as hardness, thickness, disintegration, friability and layer separation tests) were found to be satisfactory. The FTIR studies indicated the absence of interactions between the components within the individual layers, suggesting drug-excipient compatibility in all the formulations. No drug release from the slow-release layer was observed during the first hour of the dissolution study in 0.1M HCl. The release-controlling polymers had a significant effect on the release of simvastatin from the slow-release layer. Thus, the formulated bilayer tablets avoided incompatibility issues and proved the conventional release of telmisartan (85% in 45 min) and slow release of simvastatin (80% in 8 h). Stable and compatible bilayer tablets containing telmisartan and simvastatin were developed with better patient compliance as an alternative to existing conventional dosage forms.

  20. Postsynaptic Depolarization Enhances GABA Drive to Dorsomedial Hypothalamic Neurons through Somatodendritic Cholecystokinin Release.

    Science.gov (United States)

    Crosby, Karen M; Baimoukhametova, Dinara V; Bains, Jaideep S; Pittman, Quentin J

    2015-09-23

    Somatodendritically released peptides alter synaptic function through a variety of mechanisms, including autocrine actions that liberate retrograde transmitters. Cholecystokinin (CCK) is a neuropeptide expressed in neurons in the dorsomedial hypothalamic nucleus (DMH), a region implicated in satiety and stress. There are clear demonstrations that exogenous CCK modulates food intake and neuropeptide expression in the DMH, but there is no information on how endogenous CCK alters synaptic properties. Here, we provide the first report of somatodendritic release of CCK in the brain in male Sprague Dawley rats. CCK is released from DMH neurons in response to repeated postsynaptic depolarizations, and acts in an autocrine fashion on CCK2 receptors to enhance postsynaptic NMDA receptor function and liberate the retrograde transmitter, nitric oxide (NO). NO subsequently acts presynaptically to enhance GABA release through a soluble guanylate cyclase-mediated pathway. These data provide the first demonstration of synaptic actions of somatodendritically released CCK in the hypothalamus and reveal a new form of retrograde plasticity, depolarization-induced potentiation of inhibition. Significance statement: Somatodendritic signaling using endocannabinoids or nitric oxide to alter the efficacy of afferent transmission is well established. Despite early convincing evidence for somatodendritic release of neurohypophysial peptides in the hypothalamus, there is only limited evidence for this mode of release for other peptides. Here, we provide the first evidence for somatodendritic release of the satiety peptide cholecystokinin (CCK) in the brain. We also reveal a new form of synaptic plasticity in which postsynaptic depolarization results in enhancement of inhibition through the somatodendritic release of CCK. Copyright © 2015 the authors 0270-6474/15/3513160-11$15.00/0.

  1. Gaia Data Release 1. Catalogue validation

    NARCIS (Netherlands)

    Arenou, F.; Luri, X.; Babusiaux, C.; Fabricius, C.; Helmi, A.; Robin, A. C.; Vallenari, A.; Blanco-Cuaresma, S.; Cantat-Gaudin, T.; Findeisen, K.; Reylé, C.; Ruiz-Dern, L.; Sordo, R.; Turon, C.; Walton, N. A.; Shih, I.-C.; Antiche, E.; Barache, C.; Barros, M.; Breddels, M.; Carrasco, J. M.; Costigan, G.; Diakité, S.; Eyer, L.; Figueras, F.; Galluccio, L.; Heu, J.; Jordi, C.; Krone-Martins, A.; Lallement, R.; Lambert, S.; Leclerc, N.; Marrese, P. M.; Moitinho, A.; Mor, R.; Romero-Gómez, M.; Sartoretti, P.; Soria, S.; Soubiran, C.; Souchay, J.; Veljanoski, J.; Ziaeepour, H.; Giuffrida, G.; Pancino, E.; Bragaglia, A.

    Context. Before the publication of the Gaia Catalogue, the contents of the first data release have undergone multiple dedicated validation tests. Aims: These tests aim to provide in-depth analysis of the Catalogue content in order to detect anomalies and individual problems in specific objects or in

  2. Release of dissolved 85Kr by standing

    International Nuclear Information System (INIS)

    Ootsuka, Norikatsu; Yamamoto, Tadatoshi; Tsukui, Kohei

    1986-01-01

    The experiments on the release of dissolved 85 Kr by standing at room temperature were carried out to examine the influence of liquid level in a sampler and properties of solvent on the release efficiency. Six kinds of organic solvents as well as water were taken as solvents. The half-life period in case of the decrease in concentration of the dissolved 85 Kr which was used as an index of release efficiency, was proportional to the liquid level in the sampler and was inversely proportional to the diffusion coefficient of Kr gas in solvent. For organic solvents belonging to homologous series, the half-life period became longer with increasing the carbon number of solvent molecule. From the relationship between the half-life period and the carbon number, the release efficiency in the dissolved 85 Kr can be predicted for any commonly used solvent as a practical application. This method was found to be an effective means of removing the dissolved 85 Kr of low level though it takes rather long time. (author)

  3. A new release of the S3M code

    International Nuclear Information System (INIS)

    Pavlovic, M.; Bokor, J.; Regodic, M.; Sagatova, A.

    2015-01-01

    This paper presents a new release of the code that contains some additional routines and advanced features of displaying the results. Special attention is paid to the processing of the SRIM range file, which was not included in the previous release of the code. Examples of distributions provided by the S 3 M code for implanted ions in thyroid and iron are presented. (authors)

  4. Experimental evaluation of structural integrity of scram release electromagnet

    International Nuclear Information System (INIS)

    Patri, Sudheer; Ruhela, S.P.; Punniyamoorthy, R.; Vijayashree, R.; Chandramouli, S.; Kumar, P. Madan; Rajendraprasad, R.; Rao, P. Vijayamohana; Narmadha, S.; Sreedhar, B.K.; Rajan, K.K.

    2014-01-01

    Highlights: • The structural integrity of scram release electromagnet is evaluated against thermal shocks. • A simple test facility, employed for simulating the thermal shocks in a typical FBR, is presented. • The cold shock experienced by electromagnet during scram is simulated. • The testing qualified electromagnet for 11.6 yr of reactor operation. - Abstract: Prototype fast breeder reactor (PFBR), under construction at Kalpakkam, India, plays an important role in the commercialisation of fast breeder reactors (FBR) in India. It consists of two independent, fast acting and diverse shutdown systems. An electromagnet (EM) immersed in sodium acts as scram release device for the second shutdown system of prototype fast breeder reactor. The inside of EM is sealed from the sodium to achieve the required response time and to prevent the exposure of EM coil to sodium. As the EM response time is an important parameter for reactor safety, the integrity of EM is to be maintained under all anticipated loadings. The EM experiences thermal shocks and thermal stresses during reactor transients such as scram. The dissimilar weld joint present in EM is more susceptible to fatigue failure due to these thermal stresses. Failure of weld joint results in the entry of sodium into the EM, increasing its response time with associated safety implications. In this connection, the structural integrity of EM against thermal shocks was experimentally evaluated in Thermal Shock Test Facility. The EM was subjected to 1000 cycles of thermal shocks, which constitutes 29% of total number of shocks required to qualify the EM for 40 years of reactor operation, thus qualifying it for 11.6 yr of reactor operation. The testing has enhanced the confidence level for safe and reliable operation of EM of DSRDM in PFBR. The testing not only qualified the EM for use in reactor but also provided input for licensing the erection of DSRDM on reactor pile. Moreover, it provided a direction for

  5. Release rates of soluble species at Yucca Mountain

    International Nuclear Information System (INIS)

    Lee, W.W.-L.; Pigford, T.H.

    1989-02-01

    Experimental leaching of spent fuel shows that some fission product species are preferentially released upon contact with water. We analyze the conservative case of bare spent fuel in contact with saturated tuff using diffusional mass transfer analysis. For the parameter values used, the USNRC release rate limit is not exceeded, except for 99 Tc. The presence of a container and the distribution of water contact over time will assist in meeting this criterion. 6 figs., 2 tabs

  6. Studies on renin release in vitro

    DEFF Research Database (Denmark)

    Skøtt, O

    1989-01-01

    1) Measurements of renin secretion from single arterioles at time intervals down to 20 seconds showed that the renin secretion is episodic, the amount of renin released during each episode corresponding to the estimated content of one secretory granule. 2) A decrease in osmolality elicits episodi...

  7. Up-to-date, real-time localized ITS services provided on a mobile platform

    DEFF Research Database (Denmark)

    Tadayoni, Reza; Kloch, Christian

    2011-01-01

    and connection to the mobile platform, the smart phone provides the technologies and power to become the platform to provide and access up-to-date, real time infor-mation as requested by the drivers and becomes a central point for networking and coordinated actions. The purpose of this paper is to provide......-to-date infrastructure technology and is carried by lay-mans, like the smart-phones (with GPS receiver, Wi-Fi, Bluetooth, high speed cellular data connection and a large touch screen). With an 18 month replacement rate [1], and possibilities of combining navigational system, one-to-one communication, broadcast receiver...... in order to avoid local based solutions and to avoid proprietary solutions, a support that also shall be supported by political willingness above local level in order to realize the benefit of ITS....

  8. Hydrophobic ion pairing of a minocycline/Ca(2+)/AOT complex for preparation of drug-loaded PLGA nanoparticles with improved sustained release.

    Science.gov (United States)

    Holmkvist, Alexander Dontsios; Friberg, Annika; Nilsson, Ulf J; Schouenborg, Jens

    2016-02-29

    Polymeric nanoparticles is an established and efficient means to achieve controlled release of drugs. Incorporation of minocycline, an antibiotic with anti-inflammatory and neuroprotective properties, into biodegradable nanoparticles may therefore provide an efficient means to combat foreign body reactions to implanted electrodes in the brain. However, minocycline is commonly associated with poor encapsulation efficiencies and/or fast release rates due to its high solubility in water. Moreover, minocycline is unstable under conditions of low and high pH, heat and exposure to light, which exacerbate the challenges of encapsulation. In this work drug loaded PLGA nanoparticles were prepared by a modified emulsification-solvent-diffusion technique and characterized for size, drug encapsulation and in vitro drug release. A novel hydrophobic ion pair complex of minocycline, Ca(2+) ions and the anionic surfactant AOT was developed to protect minocycline from degradation and prolong its release. The optimized formulation resulted in particle sizes around 220 nm with an entrapment efficiency of 43% and showed drug release over 30 days in artificial cerebrospinal fluid. The present results constitute a substantial increase in release time compared to what has hitherto been achieved for minocycline and indicate that such particles might provide useful for sustained drug delivery in the CNS. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Release of corrosion products from construction materials containing cobalt. Pt.2: Inconel X750

    International Nuclear Information System (INIS)

    Falk, I.

    1978-02-01

    This report describes experimental work aimed at determining the release rate for corrosion products from 18Cr8Ni steel and Inconel X750 in BWR environments. For test purposes these environments were simulated in a high pressure loop, where irradiated samples of the materials were exposed for 720 hours. The amounts of released products were determined using gamma spectrometric analysis. The results show that the release from Inconel X750 is higher than that from 18Cr8Ni steel. The release calculated from Co58 measurements is 7 times higher and from Co60 measurements it is 1.5 times higher. Both the filtered and the deposited fractions of the released corrosion products exhibit the same relative concentrations of Co58 and Co60. (author)

  10. Time-dependent effect of orchidectomy on vascular nitric oxide and thromboxane A2 release. Functional implications to control cell proliferation through activation of the epidermal growth factor receptor.

    Directory of Open Access Journals (Sweden)

    Marta del Campo

    Full Text Available This study analyzes whether the release of nitric oxide (NO and thromboxane A2 (TXA2 depends on the time lapsed since gonadal function is lost, and their correlation with the proliferation of vascular smooth muscle cells (VSMC mediated by the epidermal growth factor receptor (EGFR. For this purpose, aortic and mesenteric artery segments from control and 6-weeks or 5-months orchidectomized rats were used to measure NO and TXA2 release. The results showed that the basal and acetylcholine (ACh-induced NO release were decreased 6 weeks post-orchidectomy both in aorta and mesenteric artery, but were recovered 5 months thereafter up to levels similar to those found in arteries from control rats. The basal and ACh-induced TXA2 release increased in aorta and mesenteric artery 6 weeks post-orchidectomy, and was maintained at high levels 5 months thereafter. Since we previously observed that orchidectomy, which decreased testosterone level, enlarged the muscular layer of mesenteric arteries, the effect of testosterone on VSMC proliferation was analyzed. The results showed that treatment of cultured VSMC with testosterone downregulated mitogenic signaling pathways initiated by the ligand-dependent activation of the EGFR. In contrast, the EGFR pathways were constitutively active in mesenteric arteries of long-term orchidectomized rats. Thus, the exposure of mesenteric arteries from control rats to epidermal growth factor (EGF induced the activation of EGFR signaling pathways. However, the addition of EGF to arteries from orchidectomized rats failed to induce a further activation of these pathways. In conclusion, this study shows that the release of NO depends on the time lapsed since the gonadal function is lost, while the release of TXA2 is already increased after short periods post-orchidectomy. The alterations in these signaling molecules could contribute to the constitutive activation of the EGFR and its downstream signaling pathways after long period

  11. Protective action evaluation, Part 1. Effectiveness of sheltering as a protective action against nuclear accidents involving gaseous releases

    International Nuclear Information System (INIS)

    Anno, G.H.; Dore, M.A.

    1978-04-01

    In an airborne release of radioactive material from a nuclear power plant accident, sheltering of individuals is of importance in emergency protective action planning. An analysis to estimate the effectiveness or benefit that might be derived from sheltering is described. The objective of this effort is the development of sheltering effectiveness information for those responsible for formulating required emergency plans for nuclear power plant siting. Shelter effectiveness is specifically defined as the dose reduction factor (DRF). DRF estimates for different conditions of source release, shelter structure assumptions, and operational time parameters are made for both whole-body and thyroid doses separately, based on a single-compartment structural model of the time-varying outside and inside gaseous radionuclide sources of krypton, zenon, and iodine. Design basis accident (DBA) assumptions are made for the gaseous radionuclide release. The magnitude of the release and dose estimates are based on radionuclide data from The Reactor Safety Study (WASH-1400). Source release time and duration assumptions are related to release categories PWR 1, PWR 3, and PWR 4, for which release times range from 1.5 to 2.5 hr and the release duration ranges from 0.5 to 3 hr. The basic shelter model characteristics considered are gamma ray attentuation, source geometry, gaseous fission-product ingress, and air change rate. Temporal parameters considered are source release time and duration, cloud travel time, and time spent in the shelter structure. Also, the analysis of shelter effectiveness is based on a time-frame model, which can be conveniently related to other operational times important for emergency planning. In addition to developing shelter-effectiveness estimates parametrically, the advantage of exiting and evacuating the vicinity of the shelter area after some initial time in the shelter is analyzed from the standpoint of the DRF and temporal considerations

  12. Quantification of nanoparticle release from polymer nanocomposite coatings due to environmental stressing.

    Science.gov (United States)

    Kim, Yeon Seok; Davis, Rick; Uddin, Nasir; Nyden, Marc; Rabb, Savelas A

    2016-01-01

    Certain engineered nanoparticles (ENP) reduce the flammability of components used in soft furnishings (mattresses and upholstered furniture). However, because of the ENP's small size and ability to interact with biological molecules, these fire retardant ENPs may pose a health and environmental risks, if they are released sometime during the life cycle of the soft furnishing. Quantifying the released amount of these ENPs under normal end-use circumstances provides a basis for assessing their potential health and environmental impact. In this article, we report on efforts to identify suitable methodologies for quantifying the release of carbon nanofibers, carbon nanotubes, and sodium montmorillonites from coatings applied to the surfaces of barrier fabric and polyurethane foam. The ENPs released in simulated chewing and mechanical stressing experiments were collected in aqueous solution and quantified using Ultraviolet-Visible and inductively coupled plasma-optical emission spectroscopy. The microstructures of the released ENPs were characterized using scanning electron microscopy. The reported methodology and results provide important milestones to estimate the impact and toxicity of the ENP release during the life cycle of the nanocomposites. To our knowledge, this is the first study of ENP release from the soft furnishing coating, something that can be important application area for fire safety.

  13. Tailored sequential drug release from bilayered calcium sulfate composites

    International Nuclear Information System (INIS)

    Orellana, Bryan R.; Puleo, David A.

    2014-01-01

    The current standard for treating infected bony defects, such as those caused by periodontal disease, requires multiple time-consuming steps and often multiple procedures to fight the infection and recover lost tissue. Releasing an antibiotic followed by an osteogenic agent from a synthetic bone graft substitute could allow for a streamlined treatment, reducing the need for multiple surgeries and thereby shortening recovery time. Tailorable bilayered calcium sulfate (CS) bone graft substitutes were developed with the ability to sequentially release multiple therapeutic agents. Bilayered composite samples having a shell and core geometry were fabricated with varying amounts (1 or 10 wt.%) of metronidazole-loaded poly(lactic-co-glycolic acid) (PLGA) particles embedded in the shell and simvastatin directly loaded into either the shell, core, or both. Microcomputed tomography showed the overall layered geometry as well as the uniform distribution of PLGA within the shells. Dissolution studies demonstrated that the amount of PLGA particles (i.e., 1 vs. 10 wt.%) had a small but significant effect on the erosion rate (3% vs. 3.4%/d). Mechanical testing determined that introducing a layered geometry had a significant effect on the compressive strength, with an average reduction of 35%, but properties were comparable to those of mandibular trabecular bone. Sustained release of simvastatin directly loaded into CS demonstrated that changing the shell to core volume ratio dictates the duration of drug release from each layer. When loaded together in the shell or in separate layers, sequential release of metronidazole and simvastatin was achieved. By introducing a tunable, layered geometry capable of releasing multiple drugs, CS-based bone graft substitutes could be tailored in order to help streamline the multiple steps needed to regenerate tissue in infected defects. - Highlights: • Bilayered CS composites were fabricated as potential bone graft substitutes. • The shell

  14. Tailored sequential drug release from bilayered calcium sulfate composites

    Energy Technology Data Exchange (ETDEWEB)

    Orellana, Bryan R.; Puleo, David A., E-mail: puleo@uky.edu

    2014-10-01

    The current standard for treating infected bony defects, such as those caused by periodontal disease, requires multiple time-consuming steps and often multiple procedures to fight the infection and recover lost tissue. Releasing an antibiotic followed by an osteogenic agent from a synthetic bone graft substitute could allow for a streamlined treatment, reducing the need for multiple surgeries and thereby shortening recovery time. Tailorable bilayered calcium sulfate (CS) bone graft substitutes were developed with the ability to sequentially release multiple therapeutic agents. Bilayered composite samples having a shell and core geometry were fabricated with varying amounts (1 or 10 wt.%) of metronidazole-loaded poly(lactic-co-glycolic acid) (PLGA) particles embedded in the shell and simvastatin directly loaded into either the shell, core, or both. Microcomputed tomography showed the overall layered geometry as well as the uniform distribution of PLGA within the shells. Dissolution studies demonstrated that the amount of PLGA particles (i.e., 1 vs. 10 wt.%) had a small but significant effect on the erosion rate (3% vs. 3.4%/d). Mechanical testing determined that introducing a layered geometry had a significant effect on the compressive strength, with an average reduction of 35%, but properties were comparable to those of mandibular trabecular bone. Sustained release of simvastatin directly loaded into CS demonstrated that changing the shell to core volume ratio dictates the duration of drug release from each layer. When loaded together in the shell or in separate layers, sequential release of metronidazole and simvastatin was achieved. By introducing a tunable, layered geometry capable of releasing multiple drugs, CS-based bone graft substitutes could be tailored in order to help streamline the multiple steps needed to regenerate tissue in infected defects. - Highlights: • Bilayered CS composites were fabricated as potential bone graft substitutes. • The shell

  15. Understanding and Predicting the Process of Software Maintenance Releases

    Science.gov (United States)

    Basili, Victor; Briand, Lionel; Condon, Steven; Kim, Yong-Mi; Melo, Walcelio L.; Valett, Jon D.

    1996-01-01

    One of the major concerns of any maintenance organization is to understand and estimate the cost of maintenance releases of software systems. Planning the next release so as to maximize the increase in functionality and the improvement in quality are vital to successful maintenance management. The objective of this paper is to present the results of a case study in which an incremental approach was used to better understand the effort distribution of releases and build a predictive effort model for software maintenance releases. This study was conducted in the Flight Dynamics Division (FDD) of NASA Goddard Space Flight Center(GSFC). This paper presents three main results: 1) a predictive effort model developed for the FDD's software maintenance release process; 2) measurement-based lessons learned about the maintenance process in the FDD; and 3) a set of lessons learned about the establishment of a measurement-based software maintenance improvement program. In addition, this study provides insights and guidelines for obtaining similar results in other maintenance organizations.

  16. Effect of gas release in hot molding on flexural strength of composite friction brake

    Science.gov (United States)

    Rusdja, Andy Permana; Surojo, Eko; Muhayat, Nurul; Raharjo, Wijang Wisnu

    2018-02-01

    Composite friction brake is a vital part of braking system which serves to reduce the speed of vehicle. To fulfill the requirement of brake performance, composite friction brake must have friction and mechanical characteristic as required. The characteristics of composite friction brake are affected by brake material formulation and manufacturing parameter. In the beginning of hot molding, intermittent hot pressing was carried out to release the gases that consist of ammonia gas and water vapor. In composite friction brake, phenolic resin containing hexamethylenetetramine (HMTA) is often used as a binder. During hot molding, the reaction of phenolic resin and HMTA forms ammonia gas. Hot molding also generates water vapor because raw materials absorb moisture from environment when they are placed in storage. The gas release in hot molding is supposed affecting mechanical properties because it avoid entrapped gas in composite, so that this research investigated effect of gas release on flexural strength. Manufacturing of composite specimen was carried out as follow: mixing of raw materials, cold molding, and hot molding. In this research, duration of intermittent hot pressing and number of gas release were varied. The flexural strength of specimen was measured using three point bending test. The results showed that flexural strength specimens that were manufactured without gas release, using 4 times gas release with intermittent hot pressing for 5 and 10 seconds were not remarkably different. Conversely, hot molding using 4 times gas release with intermittent hot pressing for 15 seconds decreased flexural strength of composite. Hot molding using 2, 4, and 8 times gas release with intermittent hot pressing for 10 seconds also had no effect on increasing flexural strength. Increasing of flexural strength of composite was obtained only by using 6 times gas release with intermittent hot pressing for 10 seconds.

  17. Large scientific releases

    International Nuclear Information System (INIS)

    Pongratz, M.B.

    1981-01-01

    The motivation for active experiments in space is considered, taking into account the use of active techniques to obtain a better understanding of the natural space environment, the utilization of the advantages of space as a laboratory to study fundamental plasma physics, and the employment of active techniques to determine the magnitude, degree, and consequences of artificial modification of the space environment. It is pointed out that mass-injection experiments in space plasmas began about twenty years ago with the Project Firefly releases. Attention is given to mass-release techniques and diagnostics, operational aspects of mass release active experiments, the active observation of mass release experiments, active perturbation mass release experiments, simulating an artificial modification of the space environment, and active experiments to study fundamental plasma physics

  18. Regulation of somatostatin release in the nervous system of the rat

    International Nuclear Information System (INIS)

    Sheppard, M.

    1979-08-01

    This thesis represents the work done to study the release of somatostatin from the rat central nervous system in vitro, providing some evidence for a physiological role for somatostatin. Somatostatin was measured by a sensitive and specific radioimmunoassay devoloped in the laboratory. Chapter 2 reviews the literature on hypothalamic peptides and control of an anterior pituitary function, somatostatin, other central nervous system peptides and neurosecretion. Chapter 3 describes the central nervous system tissue dissection technique, the radioimmunoassay for somatostatin and the tissue levels of somatostatin immunoreactivity in different areas of the central nervous system. Chapter 4 deals with the release of immunoreactive somatostatin from incubated rat hypothalamus in vitro and the influence of other hormones and neuropeptides on this release. Chapter 5 describes the preparation of isolated nerve endings (synaptosomes) from four different areas of rat brain, the localisation of somatostatin to the synaptosome fraction of brain homogenates and the release of somatostatin from these synaptosomes. Chapter 6 deals with the release of somatostatin from incubated rat spinal cord in vitro. Chapter 7 presents the results of the characterisation of released immunoreactive material, the technique utilised being serial dilution of immunoreactive material and comparison to the standard curve, Sephadex gel chromatography, affinity chromatography, and the effect of released immunoreactive somatostatin on growth hormone release from perifused hemipituitaries in vitro, i.e. biological activity. Chapter 8 provides a summary of the main conclusions reached in this study and is followed by the Appendix describing chemical and biochemical methods, histological techniques, and statistical methods

  19. Stimulatory effects of neuronally released norepinephrine on renin release in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Yasuo; Kawazoe, Shinka; Ichihara, Toshio; Shinyama, Hiroshi; Kageyama, Masaaki; Morimoto, Shiro (Osaka Univ. of Pharmaceutical Sciences (Japan))

    1988-10-01

    Extracellular high potassium inhibits renin release in vitro by increasing calcium concentrations in the juxtaglomerular cells. The authors found that the decreased response of renin release from rat kidney cortical slices in high potassium solution changed to a strikingly increased one in the presence of nifedipine at doses over 10{sup {minus}6} M. They then examined the stimulatory effect of extracellular high potassium in the presence of nifedipine on renin release. The enhancement of release was significantly suppressed either by propranolol or by metoprolol but not by prazosin. High potassium plus nifedipine-induced increase in renin release was markedly attenuated by renal denervation. The enhancing effect was not observed when the slices were incubated in calcium-free medium. Divalent cations such as Cd{sup 2+}, Co{sup 2+}, and Mn{sup 2+} blocked this enhancement in a concentration-dependent manner. High potassium elicited an increase in {sup 3}H efflux from the slices preloaded with ({sup 3}H)-norepinephrine. The increasing effect was not influenced by nifedipine but was abolished by the removal of extracellular calcium or by the addition of divalent cations. These observations suggest to us that the high potassium plus nifedipine-induced increase in renin release from the slices is mediated by norepinephrine derived from renal sympathetic nerves and that this neuronally released norepinephrine stimulates renin release via activation of {beta}-adrenoceptors.

  20. Scenarios and analytical methods for UF6 releases at NRC-licensed fuel cycle facilities

    International Nuclear Information System (INIS)

    Siman-Tov, M.; Dykstra, J.; Holt, D.D.; Huxtable, W.P.; Just, R.A.; Williams, W.R.

    1984-06-01

    This report identifies and discusses potential scenarios for the accidental release of UF 6 at NRC-licensed UF 6 production and fuel fabrication facilities based on a literature review, site visits, and DOE enrichment plant experience. Analytical tools needed for evaluating source terms for such releases are discussed, and the applicability of existing methods is reviewed. Accident scenarios are discussed under the broad headings of cylinder failures, UF 6 process system failures, nuclear criticality events, and operator errors and are categorized by location, release source, phase of UF 6 prior to release, release flow characteristics, release causes, initiating events, and UF 6 inventory at risk. At least three types of releases are identified for further examination: (1) a release from a liquid-filled cylinder outdoors, (2) a release from a pigtail or cylinder in a steam chest, (3) an indoor release from either (a) a pigtail or liquid-filled cylinder or (b) other indoor source depending on facility design and operating procedures. Indoor release phenomena may be analyzed to determine input terms for a ventilation model by using a time-dependent homogeneous compartment model or a more complex hydrodynamic model if time-dependent, spatial variations in concentrations, temperature, and pressure are important. Analytical tools for modeling directed jets and explosive releases are discussed as well as some of the complex phenomena to be considered in analyzing UF 6 releases both indoors and outdoors

  1. Comment on linking the sex difference in PCB concentrations of fish to release of eggs at spawning: Time to jettison the dogma

    Science.gov (United States)

    Madenjian, Charles P.

    2017-01-01

    For the past 20 years or so, a commonly used explanation in the scientific literature for higher polychlorinated biphenyl (PCB) concentrations in male fish than in female fish has been that females lose a high proportion of their PCB body burden by releasing eggs at spawning time, and therefore the females undergo a substantial decrease in their PCB concentration immediately after spawning due to shedding of their eggs [1]. Indeed, this explanation can be viewed as the conventional wisdom used by toxicologists to account for differences in PCB concentrations between the sexes of fish. On the surface, this explanation seems plausible. PCBs are lipid soluble, and eggs are thought to be relatively high in lipid concentration. If a sufficiently high proportion of the PCB body burden within a female fish is transferred to the eggs, then the release of eggs at spawning would be expected to result in a dramatic decrease in the PCB concentration of the female.

  2. Nutrient Release from Disturbance of Infiltration System Soils during Construction

    Directory of Open Access Journals (Sweden)

    Daniel P. Treese

    2012-01-01

    Full Text Available Subsurface infiltration and surface bioretention systems composed of engineered and/or native soils are preferred tools for stormwater management. However, the disturbance of native soils, especially during the process of adding amendments to improve infiltration rates and pollutant removal, may result in releases of nutrients in the early life of these systems. This project investigated the nutrient release from two soils, one disturbed and one undisturbed. The disturbed soil was collected intact, but had to be air-dried, and the columns repacked when soil shrinkage caused bypassing of water along the walls of the column. The undisturbed soil was collected and used intact, with no repacking. The disturbed soil showed elevated releases of nitrogen and phosphorus compared to the undisturbed soil for approximately 0.4 and 0.8 m of runoff loading, respectively. For the undisturbed soil, the nitrogen release was delayed, indicating that the soil disturbance accelerated the release of nitrogen into a very short time period. Leaving the soil undisturbed resulted in lower but still elevated effluent nitrogen concentrations over a longer period of time. For phosphorus, these results confirm prior research which demonstrated that the soil, if shown to be phosphorus-deficient during fertility testing, can remove phosphorus from runoff even when disturbed.

  3. Role of hemolysis in potassium release by iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, K.; Nakamura, T.; Shimizu, Y. [Department of Radiology, Kyoto City Hospital (Japan)

    1999-09-01

    It has been demonstrated that an iodinated contrast medium (CM) causes release of potassium into blood vessel lumina, resulting in an increase in serum potassium. The purpose of the present study was to assess whether this potassium release is due to hemolysis. Fresh human blood was mixed in vitro with CM at a ratio of 10:2. Potassium release rates were determined, and serum haptoglobin and free hemoglobin were measured after 30 min of exposure to CM. To compare the potassium release curve between CM exposure and true hemolysis induced by distilled water, fresh human blood was also mixed with distilled water. The level of serum haptoglobin decreased due to hemodilution. Changes in haptoglobin were not correlated with potassium release rates. The serum free hemoglobin level did not increase significantly, and there was no correlation between changes in the free hemoglobin level and the rate of potassium release. Hemolysis caused by water occurred instantaneously, whereas potassium release caused by CM was a slow response, which was linearly correlated with exposure time. Potassium release from blood cannot be explained by hemolysis. (orig.) With 4 figs., 4 tabs., 3 refs.

  4. THE STUDY ON THE EFFECT OF FORMULATION VARIABLES ON IN VITRO FLOATING TIME AND THE RELEASE PROPERTIES OF A FLOATING DRUG DELIVERY SYSTEM BY A STATISTICAL OPTIMIZATION TECHNIQUE

    Directory of Open Access Journals (Sweden)

    C. NARENDRA

    2008-03-01

    Full Text Available The present investigation concerns the evaluation of the effect of formulation variables on in vitro floating time and the release properties in developing a floating drug delivery system (FDDS containing a highly water soluble drug metoprolol tartrate (MT in the presence of a gas generating agent. A 32 full factorial design was employed in formulating the FDDS containing hydroxyl propylmethylcellulose (HPMC K4M and sodium carboxymethylcellulose (NaCMC as swellable polymers. Drug-to-polymer ratio and polymer-to-polymer ratio were included as independent variables. The main effect and the interaction terms were quantitatively evaluated by a quadratic model to predict formulations with the floating time desired, and the release properties. It was found that only drug-to-polymer ratio and its quadratic term were found to be significantly affective for all the response variables. Non-Fickian transport was confirmed as a release mechanism from the optimized formulations. The desirability function was used to optimize the response variables, each having a different target, and the observed responses were highly agreed with experimental values. The results demonstrate the feasibility of the model in the development of FDDS containing a highly water-soluble drug MT.

  5. Light-Regulated Release of Entrapped Drugs from Photoresponsive Gold Nanoparticles

    Directory of Open Access Journals (Sweden)

    Kaniknun Sreejivungsa

    2016-01-01

    Full Text Available Release of a payload in a spatiotemporal fashion has a substantial impact on increasing therapeutic efficacy. In this work, a novel monolayer of gold nanoparticles (AuNPs featuring light-responsive ligands was investigated as a potential drug carrier whose drug release can be triggered by UV light. Hydrophobic molecules were noncovalently entrapped in the compartments of its monolayers. Once irradiated with UV light, the dinitrobenzyl linker was cleaved, leading to release of the entrapped agent. AuNPs were characterized using UV spectrophotometry, TEM, and a zetasizer. A naturally occurring compound extracted from Goniothalamus elegans Ast was chosen as a hydrophobic model drug. Entrapment and release of dye were monitored using fluorimetry. The percent encapsulation of dye was of 13.53%. Entrapped dye can be released upon UV irradiation and can be regulated by changing irradiation time. Up to 83.95±2.2% entrapped dye can be released after irradiation for 20 minutes. In the absence of UV light, dye release was only 19.75%. For comparison purposes, AuNPs having no dinitrobenzyl groups showed a minimal release of 12.23% and 11.69% with and without UV light, respectively. This demonstrated an alternative strategy to encapsulate drugs using a noncovalent approach followed by their controlled release upon UV irradiation.

  6. On Expansion Of The Circle Of Norms Providing Special Types Of Release From Criminal Liability In The Chapter 22 Of The Criminal Code Of The Russian Federation

    Directory of Open Access Journals (Sweden)

    Farid A. Musaev

    2014-06-01

    Full Text Available In the article author conducts analysis of the circle of the criminal code of the Russian Federation (Charter 22 norms expansion, providing special types of release from criminal liability. Analyzes of the foreign legislation allowed author to draw a conclusion that the majority of the stimulating legal analogs to the Chapter 22 of the Criminal Code of the Russian Federation are present in the legislation of the CIS countries – Azerbaijan, Georgia, Tajikistan, Turkmenistan, Ukraine and some other, and also that release from the criminal liability on the tax crimes – is not less widespread stimulating norm in the foreign legislation. Special attention is paid to the questions of the positive post criminal behavior of persons who committed economic crime stimulation. According to the author it appears to be reasonable to include into the alternative condition of the release from criminal liability a sign of the voluntary statement of the crime commission or giving criminal income and also an alternative sign of the "active contribution to the disclosure and/or crime investigation". Author comes to the conclusion that a problem of the expansion of the stimulating norms in the Chapter 22 of the Criminal Codes of the Russian Federation action is interesting and actual in the conditions of criminal legislation in the economic sphere liberalization. In particular, in the foreshortening of the economic amnesty questions author believes that introduction of the stimulating norms of the Chapter 186 of the Criminal Code of the Russian Federation isn't expected soon.

  7. Development of New Gonadotropin-Releasing Hormone-Modified Dendrimer Platforms with Direct Antiproliferative and Gonadotropin Releasing Activity.

    Science.gov (United States)

    Varamini, Pegah; Rafiee, Amirreza; Giddam, Ashwini Kumar; Mansfeld, Friederike M; Steyn, Frederik; Toth, Istvan

    2017-10-26

    Gonadotropin-releasing hormone (GnRH) agonists (e.g., triptorelin) are used for androgen suppression therapy. They possess improved stability as compared to the natural GnRH, yet they suffer from a poor pharmacokinetic profile. To address this, we used a GnRH peptide-modified dendrimer platform with and without lipidation strategy. Dendrimers were synthesized on a polylysine core and bore either native GnRH (1, 2, and 5) or lipid-modified GnRH (3 and 4). Compound 3, which bore a lipidic moiety in a branched tetramer structure, showed approximately 10-fold higher permeability and metabolic stability and 39 times higher antitumor activity against hormone-resistant prostate cancer cells (DU145) relative to triptorelin. In gonadotropin-release experiments, dendrimer 3 was shown to be the most potent construct. Dendrimer 3 showed similar luteinizing hormone (LH)-release activity to triptorelin in mice. Our findings indicate that dendrimer 3 is a promising analog with higher potency for the treatment of hormone-resistant prostate cancer than the currently available GnRH agonists.

  8. Profile of extended-release oxycodone/acetaminophen for acute pain

    Directory of Open Access Journals (Sweden)

    Bekhit MH

    2015-10-01

    Full Text Available Mary Hanna Bekhit1–51David Geffen School of Medicine, 2Ronald Reagan UCLA Medical Center, 3UCLA Ambulatory Surgery Center, 4UCLA Wasserman Eye Institute, 5UCLA Martin Luther King Community Hospital, University of California Los Angeles, Los Angeles, CA, USA Abstract: This article provides a historical and pharmacological overview of a new opioid analgesic that boasts an extended-release (ER formulation designed to provide both immediate and prolonged analgesia for up to 12 hours in patients who are experiencing acute pain. This novel medication, ER oxycodone/acetaminophen, competes with current US Food and Drug Administration (FDA-approved opioid formulations available on the market in that it offers two benefits concurrently: a prolonged duration of action, and multimodal analgesia through a combination of an opioid (oxycodone with a nonopioid component. Current FDA-approved combination analgesics, such as Percocet (oxycodone/acetaminophen, are available solely in immediate-release (IR formulations. Keywords: opioid, analgesic, xartemis, acute postsurgical pain, substance abuse, acetaminophen, extended release 

  9. Contact: Releasing the news

    Science.gov (United States)

    Pinotti, Roberto

    The problem of mass behavior after man's future contacts with other intelligences in the universe is not only a challenge for social scientists and political leaders all over the world, but also a cultural time bomb as well. In fact, since the impact of CETI (Contact with Extraterrestrial Intelligence) on human civilization, with its different cultures, might cause a serious socio-anthropological shock, a common and predetermined worldwide strategy is necessary in releasing the news after the contact, in order to keep possible manifestations of fear, panic and hysteria under control. An analysis of past studies in this field and of parallel historical situations as analogs suggests a definite "authority crisis" in the public as a direct consequence of an unexpected release of the news, involving a devastating "chain reaction" process (from both the psychological and sociological viewpoints) of anomie and maybe the collapse of today's society. The only way to prevent all this is to prepare the world's public opinion concerning contact before releasing the news, and to develop a long-term strategy through the combined efforts of scientists, political leaders, intelligence agencies and the mass media, in order to create the cultural conditions in which a confrontation with ETI won't affect mankind in a traumatic way. Definite roles and tasks in this multi-level model are suggested.

  10. Field demonstration of CO2 leakage detection in potable aquifers with a pulselike CO2-release test.

    Science.gov (United States)

    Yang, Changbing; Hovorka, Susan D; Delgado-Alonso, Jesus; Mickler, Patrick J; Treviño, Ramón H; Phillips, Straun

    2014-12-02

    This study presents two field pulselike CO2-release tests to demonstrate CO2 leakage detection in a shallow aquifer by monitoring groundwater pH, alkalinity, and dissolved inorganic carbon (DIC) using the periodic groundwater sampling method and a fiber-optic CO2 sensor for real-time in situ monitoring of dissolved CO2 in groundwater. Measurements of groundwater pH, alkalinity, DIC, and dissolved CO2 clearly deviated from their background values, showing responses to CO2 leakage. Dissolved CO2 observed in the tests was highly sensitive in comparison to groundwater pH, DIC, and alkalinity. Comparison of the pulselike CO2-release tests to other field tests suggests that pulselike CO2-release tests can provide reliable assessment of geochemical parameters indicative of CO2 leakage. Measurements by the fiber-optic CO2 sensor, showing obvious leakage signals, demonstrated the potential of real-time in situ monitoring of dissolved CO2 for leakage detection at a geologic carbon sequestration (GCS) site. Results of a two-dimensional reactive transport model reproduced the geochemical measurements and confirmed that the decrease in groundwater pH and the increases in DIC and dissolved CO2 observed in the pulselike CO2-release tests were caused by dissolution of CO2 whereas alkalinity was likely affected by carbonate dissolution.

  11. The current status of ARAC [Atmospheric Release Advisory Capability] and its application to the Chernobyl event

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Sullivan, T.J.; Harvey, T.F.

    1986-10-01

    The Atmospheric Release Advisory Capability (ARAC) project, developed by the Lawrence Livermore National Laboratory (LLNL), provides real-time dose assessments and estimates of the extent of surface contamination that may result from an atmospheric release of radioactivity. It utilizes advanced computer-based data communication and processing systems to acquire the meteorological and source term information needed by the three-dimensional atmospheric dispersion models to derive the consequence assessments. The ARAC responded to the recent Chernobyl reactor accident in the Soviet Union by estimating the source term and the radiation dose distribution due to exposure to the radioactive cloud over Europe and the Northern Hemisphere. This analysis revealed that approximately 50% of the estimated core inventories of I-131 and Cs-137 were released. The estimated committed effective dose equivalent due to inhalation of radioactivty during cloud passage is of the order of 10 mrem within parts of Scandinavia and eastern Europe, while most of the populations within central Europe were exposed to levels ranging from 1 to 10 mrem. The amount of Cs-137 released by the Chernobyl accident far exceeds that released by previous reactor accidents, but is only about 6% of the Cs-137 produced by the atmospheric weapon testing programs. 9 refs., 4 figs., 2 tabs

  12. Lateral Cricoarytenoid Release: Development of a Novel Surgical Treatment Option for Adductor Spasmodic Dysphonia in a Canine Laryngeal Model.

    Science.gov (United States)

    Park, Andrea M; Paniello, Randal C

    2016-09-01

    To investigate the efficacy of a novel adductor muscle-releasing technique designed to decrease the force of vocal fold adduction, as a potential surgical therapy for patients with adductor spasmodic dysphonia (ADSD). Experimental animal study. A canine laryngeal model was used to assess the acute and sustained efficacy of a lateral cricoarytenoid (LCA) muscle release. A total of 34 canine hemilaryngeal preparations were divided among 7 experimental groups. The LCA muscle was separated from its cricoid cartilage origin via an open, anterior, submucosal approach. The laryngeal adductory pressures (LAP) were assessed pre- and post-muscle release via direct recurrent laryngeal nerve stimulation. Measurements were repeated at 1.5, 3, or 6 months postoperatively. Another study evaluated release of the thyroarytenoid (TA) muscle from its thyroid cartilage origin. Releasing the LCA muscle demonstrated a significant decrease in LAP acutely and was maintained at all 3 time points with the aid of a barrier (P < .05). Without the barrier, the LCA muscle reattached to the cricoid. Acute release of the TA muscle did not significantly decrease the LAP. The proposed LCA release procedure may provide patients with a permanent treatment option for ADSD. However, longer-term studies and human trials are needed. © The Author(s) 2016.

  13. SRNL EMERGENCY RESPONSE CAPABILITY FOR ATMOSPHERIC CONTAMINANT RELEASES

    International Nuclear Information System (INIS)

    Koffman, L; Chuck Hunter, C; Robert Buckley, R; Robert Addis, R

    2006-01-01

    Emergency response to an atmospheric release of chemical or radiological contamination is enhanced when plume predictions, field measurements, and real-time weather information are integrated into a geospatial framework. The Weather Information and Display (WIND) System at Savannah River National Laboratory (SRNL) utilizes such an integrated framework. The rapid availability of predictions from a suite of atmospheric transport models within this geospatial framework has proven to be of great value to decision makers during an emergency involving an atmospheric contaminant release

  14. Early and late histamine release induced by albumin, hetastarch and polygeline: some unexpected findings.

    Science.gov (United States)

    Celik, I; Duda, D; Stinner, B; Kimura, K; Gajek, H; Lorenz, W

    2003-10-01

    The perioperative use of colloidal plasma substitutes is still under discussion. We therefore conducted a prospective randomised study with three commonly used plasma substitutes to examine their histamine releasing effects in 21 volunteers. MATERIAL OR SUBJETS: 21 male volunteers were enrolled in this prospective, randomised, controlled clinical study. Endpoints were the incidence of early and late histamine release and the time course of the release kinetics. Normovolemic hemodilution technique was used with hydroxyethyl starch (n = 6), human albumin (n = 6) and polygeline (n = 9). Measurement and observation period was 240 min after the start of the plasma substitute infusion. Heart rate, blood pressure, SaO(2), clinical symptoms/signs and plasma histamine were measured during the observation period. The incidence of histamine release over the whole observation period in all three groups was 100%. Histamine release occurred frequently in all three groups until 30 min (50%-78%) and up to 240 min (late release reaction: 67%-83%) after the start of infusion. Surprisingly even hydroxyethyl starch, which is regarded as a generally safe and effective plasma substitute, caused high incidences of late histamine release (67%). Histamine release is a well known side effect of polygeline and - to a lesser extent - also of albumin, but was a novel finding for hydroxyethyl starch. We demonstrated for the first time histamine releasing effects of hydroxyethyl starch over a long period of time after administration. This perioperatively and for intensive care possibly relevant finding should make clinicians aware of late side effects not yet connected with the clinical use of these colloidal plasma substitutes.

  15. Balancing Time-to-Market and Quality in Embedded Systems

    NARCIS (Netherlands)

    van der Spek, P.; Verhoef, C.

    2014-01-01

    Finding a balance between the time-to-market and quality of a delivered product is a daunting task. The optimal release moment is not easily found. We propose to use historical project data to monitor the progress of running projects. From the data we inferred a formula providing a rough indication

  16. MISTRAL V1.1.1: assessing doses from atmospheric releases in normal and off-normal conditions

    International Nuclear Information System (INIS)

    David Kerouanton; Patrick Devin; Malvina Rennesson

    2006-01-01

    Protecting the environment and the public from radioactive and chemical hazards has always been a top priority for all companies operating in the nuclear domain. In this scope, SGN provides all the services the nuclear industry needs in environmental studies especially in relation to the impact assessment in normal operating conditions and risk assessment in off-normal conditions. In order to quantify dose impact on members of the public due to atmospheric releases, COGEMA and SGN developed MISTRAL V1.1.1 code. Dose impact depends strongly on dispersion of radionuclides in atmosphere. The main parameters involved in dispersion characterization are wind velocity and direction, rain, diffusion conditions, coordinates of the point of observation and stack elevation. MISTRAL code implements DOURY and PASQUILL Gaussian plume models which are widely used in the scientific community. These models, applicable for distances of transfer ranging from 100 m up to 30 km, are used to calculate atmospheric concentration and deposit at different distances from the point of release. MISTRAL allows the use of different dose regulations or dose coefficient databases such as: - ICRP30 and ICPR71 for internal doses (inhalation, ingestion) - Despres/Kocher database or US-EPA Federal Guidance no.12 (ICPR72 for noble gases) for external exposure (from plume or ground). The initial instant of the release can be considered as the origin of time or a date format can be specified (could be useful in a crisis context). While the context is specified, the user define the meteorological conditions of the release. In normal operating mode (routine releases), the user gives the annual meteorological scheme. The data can be recorded in the MISTRAL meteorological database. In off-normal conditions mode, MISTRAL V1.1 allows the use of successive release stages for which the user gives the duration, the meteorological conditions, that is to say stability class, wind speed and direction and rainfall

  17. Estimation of cobalt release from feed water heater tubes of BWRs

    International Nuclear Information System (INIS)

    Uchida, S.; Kitamura, M.; Ozawa, Y.

    1983-01-01

    To evaluate the release source of cobalt from heater tubes of the feed water line, release rate measurements were carried out by detecting 60 Co released from irradiated stainless steel in contact with neutral water at an oxygen concentration of 20 ppb. The dependences of cobalt release rate on temperature, flow velocity and exposure time were studied after 670 hours of release experiments, and an empirical equation (which is presented) was obtained in the temperature range from 150 to 240 deg C. A decrease in the cobalt release rate above 250 deg C was considered due to the formation of a protective oxide layer. From these data, the amount of cobalt released from individual feed water heaters was evaluated. It was demonstrated that low cobalt containing stainless steel was economically applied only in the higher temperature region of the heater (20% of the total surface) to reduce cobalt feed rate into the reactor (to approx. 1/2). (author)

  18. PWR-GALE, Radioactive Gaseous Release and Liquid Release from PWR

    International Nuclear Information System (INIS)

    Chandrasekaran, T.; Lee, J.Y.; Willis, C.A.

    1988-01-01

    1 - Description of program or function: The PWR-GALE (Boiling Water Reactor Gaseous and Liquid Effluents) Code is a computerized mathematical model for calculating the release of radioactive material in gaseous and liquid effluents from pressurized water reactors (PWRs). The calculations are based on data generated from operating reactors, field tests, laboratory tests, and plant-specific design considerations incorporated to reduce the quantity of radioactive materials that may be released to the environment. 2 - Method of solution: GALE calculates expected releases based on 1) standardized coolant activities derived from ANS Standards 18.1 Working Group recommendations, 2) release and transport mechanisms that result in the appearance of radioactive material in liquid and gaseous waste streams, 3) plant-specific design features used to reduce the quantities of radioactive materials ultimately released to the environs, and 4) information received on the operation of nuclear power plants. 3 - Restrictions on the complexity of the problem: The liquid release portion of GALE uses subroutines taken from the ORIGEN (CCC-217) to calculate radionuclide buildup and decay during collection, processing, and storage of liquid radwaste. Memory requirements for this part of the program are determined by the large nuclear data base accessed by these subroutines

  19. Modulation of precipitation by conditional symmetric instability release

    Science.gov (United States)

    Glinton, Michael R.; Gray, Suzanne L.; Chagnon, Jeffrey M.; Morcrette, Cyril J.

    2017-03-01

    Although many theoretical and observational studies have investigated the mechanism of conditional symmetric instability (CSI) release and associated it with mesoscale atmospheric phenomena such as frontal precipitation bands, cloud heads in rapidly developing extratropical cyclones and sting jets, its climatology and contribution to precipitation have not been extensively documented. The aim of this paper is to quantify the contribution of CSI release, yielding slantwise convection, to climatological precipitation accumulations for the North Atlantic and western Europe. Case studies reveal that CSI release could be common along cold fronts of mature extratropical cyclones and the North Atlantic storm track is found to be a region with large CSI according to two independent CSI metrics. Correlations of CSI with accumulated precipitation are also large in this region and CSI release is inferred to be occurring about 20% of the total time over depths of over 1 km. We conclude that the inability of current global weather forecast and climate prediction models to represent CSI release (due to insufficient resolution yet lack of subgrid parametrization schemes) may lead to errors in precipitation distributions, particularly in the region of the North Atlantic storm track.

  20. Extended Release of an Anti–Heparan Sulfate Peptide From a Contact Lens Suppresses Corneal Herpes Simplex Virus-1 Infection

    Science.gov (United States)

    Jaishankar, Dinesh; Buhrman, Jason S.; Valyi-Nagy, Tibor; Gemeinhart, Richard A.; Shukla, Deepak

    2016-01-01

    Purpose To prolong the release of a heparan sulfate binding peptide, G2-C, using a commercially available contact lens as a delivery vehicle and to demonstrate the ability of the released peptide to block herpes simplex virus-1 (HSV-1) infection using in vitro, ex vivo, and in vivo models of corneal HSV-1 infection. Methods Commercially available contact lenses were immersed in peptide solution for 5 days prior to determining the release of the peptide at various time points. Cytotoxicity of the released samples was determined by MTT and cell cycle analysis, and the functional activity of the released samples were assessed by viral entry, and viral spread assay using human corneal epithelial cells (HCE). The ability to suppress infection in human and pig cornea ex vivo and mouse in vivo models were also assessed. Results Peptide G2-C was released through the contact lens. Following release for 3 days, the peptide showed significant activity by inhibiting HSV-1 viral entry and spread in HCE cells. Significant suppression of infection was also observed in the ex vivo and in vivo experiments involving corneas. Conclusions Extended release of an anti–HS peptide through a commercially available contact lens can generate significant anti–HSV-1 activity and provides a new and effective way to control corneal herpes. PMID:26780322

  1. Tritium release of titan-tritium layers in air, aqueous solutions and living organisms of animals

    International Nuclear Information System (INIS)

    Biro, J.; Feher, I.; Mate, L.; Varga, L.

    1978-01-01

    Samples containing 400-1100 MBq (10-30 mCi) tritium were prepared and the effect of storage time on tritium release was followed. In 250 days one thousandth of the tritium was released in aqueous solution; in air the ratio of release per hour fell in the range of 10 -6 -10 -7 . Ti-T plates with different storage times were surgically placed in the abdomen of rats. Their tritium release dropped with time and the activity appearing in the circulation was lower than that of plates with 5-6 orders of magnitude. Checking the tritium incorporation of neutron generator operators it must be held in mind that only a minor part of tritium can be detected by the measurement of the tritium content of urine. (author)

  2. Stimuli responsive nanomaterials for controlled release applications

    KAUST Repository

    Li, Song; Li, Wengang; Khashab, Niveen M.

    2012-01-01

    applications. Stimuli-responsive nanomaterials guarantee the controlled release of cargo to a given location, at a specific time, and with an accurate amount. In this review, we have combined the major stimuli that are currently used to achieve the ultimate

  3. Press releases — the new trend in science communication

    DEFF Research Database (Denmark)

    Autzen, Charlotte

    2014-01-01

    Scientific institutions have for a long time known the importance of framing and owning stories about science They also know the effective way of communicating science in a press release This is part of the institution’s public relations. Enhanced competition among research institutions has led...... to a buildup of communicative competences and professionalization of public relations inside the institutions and the press release has become an integrated part of science communication from these institutions. Changing working conditions in the media, where fewer people have to publish more, have made press...... releases from trustworthy scientific institutions into free and easily copied content for the editors. In this commentary I investigate and discuss the communicative ecosystem of the university press release. I especially take a close look at the role of the critical and independent science journalist...

  4. Decontamination and management of human remains following incidents of hazardous chemical release.

    Science.gov (United States)

    Hauschild, Veronique D; Watson, Annetta; Bock, Robert

    2012-01-01

    To provide specific guidance and resources for systematic and orderly decontamination of human remains resulting from a chemical terrorist attack or accidental chemical release. A detailed review and health-based decision criteria protocol is summarized. Protocol basis and logic are derived from analyses of compound-specific toxicological data and chemical/physical characteristics. Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present, such as sites of transportation accidents, terrorist operations, or medical examiner processing points. Guidance is developed from data-characterizing controlled experiments with laboratory animals, fabrics, and materiel. Logic and specific procedures for decontamination and management of remains, protection of mortuary affairs personnel, and decision criteria to determine when remains are sufficiently decontaminated are presented. Established procedures as well as existing materiel and available equipment for decontamination and verification provide reasonable means to mitigate chemical hazards from chemically exposed remains. Unique scenarios such as those involving supralethal concentrations of certain liquid chemical warfare agents may prove difficult to decontaminate but can be resolved in a timely manner by application of the characterized systematic approaches. Decision criteria and protocols to "clear" decontaminated remains for transport and processing are also provided. Once appropriate decontamination and verification have been accomplished, normal procedures for management of remains and release can be followed.

  5. An Investigation on Metallic Ion Release from Four Dental Casting Alloys

    Directory of Open Access Journals (Sweden)

    F. Nejatidanesh

    2005-12-01

    Full Text Available Statement of Problem: Element release from dental casting alloys into the oral environment is of clinical concern and is considered to be a potential health problem to all patients.Purpose: The aim of this study was to investigate the metallic ion release of four base metal alloys.Materials and Methods: Two Ni-Cr (Minalux and Supercast and two Co-Cr alloys (Minalia and Wironit were examined. Nine specimens of each type were prepared in 13×11×1.4 mm dimensions and each of the four alloys (3 specimens per group were conditioned in artificial saliva at 37 c for one, three and seven days.The conditioning media were analyzed for element-release using Inductive CoupledPlasma Atomic Emission Spectrophotometer (ICPAES. Collected data were statistically analyzed using ANOVA and Duncan multiple range test (P< 0.05.Results: The greatest amount of element release was seen after seven days (134.9 ppb Supercast, 159.2 ppb Minalux, 197.2 ppb Minalia, and 230.2 ppb Wironit. There was a significant difference between the released elements from the alloys after the three conditioning times (p<0.001.Conclusion: Element release from the studied alloys is proportional to the conditioning time. The Ni-Cr alloys tested in this investigation were more resistant to corrosion as compared to the Co-Cr alloys in artificial saliva. Supercast had the highest corrosion resistance.

  6. Probabilistic consequence assessment of hydrogen sulphide releases from a heavy water plant

    International Nuclear Information System (INIS)

    1983-06-01

    This report is the second in a series concerned with the evaluation of the consequences to the public of an accidental release of hydrogen sulphide (H 2 S) to the atmosphere following a pipe or pressure envelope failure, or some other process upset, at a heavy water plant. It consists of documentation of the code GASPROB, which has been developed to provide consequence probabilities for a range of postulated releases. The code includes mathematical simulations of initial gas behaviour upon release to the atmosphere, such as gravitational settling of a cold release and the rise of jets and flares, subsequent atmospheric dispersion under a range of weather conditions, and the toxic effects on the exposed population. The code makes use of the site-specific dispersion climatology, topography and population distribution, as well as the probabilistic lethal dose data for the released gas. Output for a given postulated release can be provided in terms of the concentration of the gas at ground level around the point of release, projected numbers of fatalities within specified areas and the projected total fatalities regardless of location. This report includes a general description of GASPROB, and specifics of the code structure, the function of each subroutine, input and output data, and the permanent data files established. Three appendices to the report contain a complete code listing, detailed subroutine descriptions and a sample output

  7. Effects of release procedures on the primary stress response and post-release survival and growth of hatchery-reared spotted seatrout Cynoscion nebulosus.

    Science.gov (United States)

    Guest, T W; Rakocinski, C F; Evans, A N; Blaylock, R B

    2017-03-01

    To help explain the apparent poor post-release success of hatchery-reared (HR) spotted seatrout Cynoscion nebulosus, this study examined the effects of handling, transport and release procedures on the stress response of two age classes [48 and 80 day post-hatch (dph)] of HR C. nebulosus, as measured by cortisol concentrations and the post-release survival and growth of 48 and 80 dph HR C. nebulosus. As a proxy for stress, tissue cortisol was measured at various times during the handling, tagging (80 dph), transport, acclimation and release process. To consider the implications of the pre-release stressors, growth and survival were monitored in separate field experiments for each age class of acclimated post-transport C. nebulosus using control C. nebulosus that only experienced anaesthesia, transport, acclimation and a net release v. experimental C. nebulosus that underwent the entire routine procedure, including anaesthesia, tagging, transport, acclimation and gravity release through a pipe. For 48 dph C. nebulosus, mean cortisol varied significantly throughout handling and transport, increasing more than six-fold from controls before decreasing in mean concentration just prior to release. For 80 dph C. nebulosus, cortisol varied throughout handling, tagging and transport, first increasing more than three-fold compared with control C. nebulosus, before decreasing and rising slightly just prior to release. For 48 dph C. nebulosus within field enclosures, survival was high and similar for control and experimental groups; experimental C. nebulosus, however, were shorter, lighter and lower in condition than control C. nebulosus. For 80 dph C. nebulosus within field enclosures, fewer experimental C. nebulosus survived and those that did survive were of lower condition than C. nebulosus from the control group. Small untagged C. nebulosus may survive the release procedure better than larger C. nebulosus carrying a coded-wire tag. These findings document

  8. Limits for the release of uranium compounds to the environment

    International Nuclear Information System (INIS)

    Lopez, F.; Ferruz, P.; Aguayo, A.

    1987-01-01

    A conservative criteria to be be followed by a Regulatory Body, in order to provide the limits of radioactive material release in the environment, When all the parameters are not available for the optimization of radiation protection is presented. This criteria can be applied to stablishment of radioactive release limits for uranium compounds from the nuclear fuel cycle facilities. (author)

  9. Pollutant Release and Transfer Register; Emissieregistratie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    Since 1974 a number of organisations have been working closely together in this pollutant register (PRTR) project to collect and formally establish the yearly releases of pollutants to air, water and soil in the Netherlands. Results of this project serve to underpin the national environmental policy. Data is in this way also provided for the many environmental reports to international organisations such as the European Union and the United Nations, e.g. the National Inventory Report for the Kyoto Protocol. This website shows the yearly releases (emissions) of the most important pollutants in the Netherlands. You can explore the emission data through various channels, such as maps, graphs and tables. But you can also download all the details into your own database. The data shown in this website is updated 2 to 3 times a year. The current release shows emissions for 1990, 1995, 2000, 2004, 2005 and 2006 The 2006 emissions are preliminary data and not yet shown in the maps. We expect to add an extra year in August 2008. [Dutch] Sinds 1974 werkt een groot aantal organisaties hecht samen in het project Emissieregistratie. Doel is het jaarlijks verzamelen en vaststellen van de uitstoot van verontreinigende stoffen naar lucht, water en bodem. Het project levert zo de emissiegegevens voor onderbouwing van milieubeleid. Het vormt de basis voor vele rapportages, bijvoorbeeld die in het kader van het Kyoto protocol. Deze website toont de geregionaliseerde uitstoot (emissie) van ruim 300 verontreinigende stoffen in Nederland. U vindt deze emissies op diverse manieren: als kaart, grafiek en tabel maar ook in de vorm van een database voor eigen gebruik. U vindt hier de emissies uit de inventarisatieronde vastgesteld in juli 2007 voor de emissiejaren 1990, 1995, 2000, 2004, 2005 en de voorlopige cijfers van 2006. De emissies uit 2006 zijn wel gedetailleerd per bron aanwezig maar u vindt ze nog niet op de kaart gepresenteerd. In augustus 2008 verwachten we de volgende ronde te

  10. Fluoride release from fluoride varnishes under acidic conditions.

    Science.gov (United States)

    Lippert, F

    2014-01-01

    The aim was to investigate the in vitro fluoride release from fluoride varnishes under acidic conditions. Poly(methyl methacrylate) blocks (Perspex, n=3 per group) were painted with 80 ± 5 mg fluoride varnish (n=10) and placed into artificial saliva for 30 min. Then, blocks were placed into either 1% citric acid (pH 2.27) or 0.3% citric acid (pH 3.75) solutions (n=3 per solution and varnish) for 30 min with the solutions being replaced every 5 min. Saliva and acid solutions were analyzed for fluoride content. Data were analyzed using three-way ANOVA (varnish, solution, time). The three-way interaction was significant (p>0.0001). Fluoride release and release patterns varied considerably between varnishes. Fluoride release in saliva varied by a factor of more than 10 between varnishes. Some varnishes (CavityShield, Nupro, ProFluorid, Vanish) showed higher fluoride release in saliva than during the first 5 min of acid exposure, whereas other varnishes (Acclean, Enamel-Pro, MI Varnish, Vella) showed the opposite behavior. There was little difference between acidic solutions. Fluoride release from fluoride varnishes varies considerably and also depends on the dissolution medium. Bearing in mind the limitations of laboratory research, the consumption of acidic drinks after fluoride varnish application should be avoided to optimize the benefit/risk ratio.

  11. Metal release behavior of surface oxidized stainless steels into flowing high temperature pure water

    International Nuclear Information System (INIS)

    Fujiwara, Kazuo; Tomari, Haruo; Nakayama, Takenori; Shimogori, Kazutoshi; Ishigure, Kenkichi; Matsuura, Chihiro; Fujita, Norihiko; Ono, Shoichi.

    1987-01-01

    In order to clarify the effect of oxidation treatment of Type 304 SS on the inhibition of metal release into high temperature pure water, metal release rate of individual alloying element into flowing deionized water containing 50 ppb dissolved oxygen was measured as the function of exposure time on representative specimens oxidized in air and steam. The behavior of metal release was also discussed in relation to the structure of surface films. Among the alloying elements the amount of Fe ion, Cr ion and Fe crud in high temperature pure water tended to saturate with the exposure time and that of Ni ion and Co ion tended to increase monotonously with the exposure time for all specimens tested. And the treatment of steam-oxidation was the most effective to decrease the metal release of alloying elements and the treatment by air-oxidation also decreased the metal release. These tendencies were confirmed to correlate well with the structure of the surface films as it was in the results in the static autoclave test. (author)

  12. Heat release from wood wall assemblies using oxygen consumption method

    Science.gov (United States)

    Hao C. Tran; Robert E. White

    1990-01-01

    The concept of heat release rate is gaining acceptance in the evaluation of fire performance of materials and assemblies. However, this concept has not been incorporated into fire endurance testing such as the ASTM E-119 test method. Heat release rate of assemblies can be useful in determining the time at which the assemblies start to contribute to the controlled fire...

  13. Noble Gas Release Signal as a Precursor to Fracture

    Science.gov (United States)

    Bauer, S. J.; Lee, H.; Gardner, W. P.

    2017-12-01

    We present empirical results of rock strain, microfracturing, acoustic emissions, and noble gas release from laboratory triaxial experiments for a granite, basalt, shale and bedded rock salt. Noble gases are released and measured real-time during deformation using mass spectrometry. The gas release represents a precursive signal to macrofracture. Gas release is associated with increased acoustic emissions indicating that microfracturing is required to release gas and create pathways for the gas to be sensed. The gas released depends on initial gas content, pore structure and its evolution during deformation, the deformation amount, matrix permeability, deformation style and the stress/strain history. Gases are released from inter and intracrystalline sites; release rate increases as strain and microfracturing increases. The gas composition depends on lithology, geologic history and age, fluids present, and radioisotope concentrations that affect radiogenic noble gas isotope (e.g. 4He,40Ar) production. Noble gas emission and its relationship to crustal processes such as seismicity and volcanism, tectonic velocities, qualitative estimates of deep permeability, age dating of groundwater, and a signature of nuclear weapon detonation. Our result show that mechanical deformation of crustal materials is an important process controlling gas release from rocks and minerals, and should be considered in techniques which utilize gas release and/or accumulation. We propose using noble gas release to signal rock deformation in boreholes, mines and waste repositories. We postulate each rock exhibits a gas release signature which is microstructure, stress, strain, and/or permanent deformation dependent. Calibration of such relationships, for example relating gas release per rock unit volume to strain may be used to quantify rock deformation and develop predictive models.Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and

  14. Nitric Oxide Release for Improving Performance of Implantable Chemical Sensors - A Review.

    Science.gov (United States)

    Cha, Kyoung Ha; Wang, Xuewei; Meyerhoff, Mark E

    2017-12-01

    Over the last three decades, there has been extensive interest in developing in vivo chemical sensors that can provide real-time measurements of blood gases (oxygen, carbon dioxide, and pH), glucose/lactate, and potentially other critical care analytes in the blood of hospitalized patients. However, clot formation with intravascular sensors and foreign body response toward sensors implanted subcutaneously can cause inaccurate analytical results. Further, the risk of bacterial infection from any sensor implanted in the human body is another major concern. To solve these issues, the release of an endogenous gas molecule, nitric oxide (NO), from the surface of such sensors has been investigated owing to NO's ability to inhibit platelet activation/adhesion, foreign body response and bacterial growth. This paper summarizes the importance of NO's therapeutic potential for this application and reviews the publications to date that report on the analytical performance of NO release sensors in laboratory testing and/or during in vivo testing.

  15. Production Planning with Load Dependent Lead Times

    DEFF Research Database (Denmark)

    Pahl, Julia

    2005-01-01

    Lead times impact the performance of the supply chain significantly. Although there is a large literature concerning queuing models for the analysis of the relationship between capacity utilization and lead times, and there is a substantial literature concerning control and order release policies...... that take lead times into consideration, there have been only few papers describing models at the aggregate planning level that recognize the relationship between the planned utilization of capacity and lead times. In this paper we provide an in-depth discussion of the state-of-the art in this literature......, with particular attention to those models that are appropriate at the aggregate planning level....

  16. In Vivo Imaging of the Stability and Sustained Cargo Release of an Injectable Amphipathic Peptide-Based Hydrogel.

    Science.gov (United States)

    Oyen, Edith; Martin, Charlotte; Caveliers, Vicky; Madder, Annemieke; Van Mele, Bruno; Hoogenboom, Richard; Hernot, Sophie; Ballet, Steven

    2017-03-13

    Hydrogels are promising materials for biomedical applications such as tissue engineering and controlled drug release. In the past two decades, the peptide hydrogel subclass has attracted an increasing level of interest from the scientific community because of its numerous advantages, such as biocompatibility, biodegradability, and, most importantly, injectability. Here, we report on a hydrogel consisting of the amphipathic hexapeptide H-FEFQFK-NH 2 , which has previously shown promising in vivo properties in terms of releasing morphine. In this study, the release of a small molecule, a peptide, and a protein cargo as representatives of the three major drug classes is directly visualized by in vivo fluorescence and nuclear imaging. In addition, the in vivo stability of the peptide hydrogel system is investigated through the use of a radiolabeled hydrogelator sequence. Although it is shown that the hydrogel remains present for several days, the largest decrease in volume takes place within the first 12 h of subcutaneous injection, which is also the time frame wherein the cargos are released. Compared to the situation in which the cargos are injected in solution, a prolonged release profile is observed up to 12 h, showing the potential of our hydrogel system as a scaffold for controlled drug delivery. Importantly, this study elucidates the release mechanism of the peptide hydrogel system that seems to be based on erosion of the hydrogel providing a generally applicable controlled release platform for small molecule, peptide, and protein drugs.

  17. H2S release rate assessment guidelines and audit forms

    International Nuclear Information System (INIS)

    Johnson, S.; Wilson, T.; Long, R.; Shewan, K.; Nchkalo, H.; Nelson, R.; Morand, M.

    1998-01-01

    Development of a process to evaluate and calculate potential hydrogen sulfide release has been recommended by the Canadian Association of Petroleum Producers' Drilling and Completion Committee, and the Alberta Energy and Utilities Board. To facilitate the process, CAPP has released guidelines describing a methodology and standard for the industry to calculate the potential hydrogen sulfide release rates of a well, and a standardized format for the documentation and retention of data. The Guidelines describe a four-step process, with each step having an increasing degree of complexity. Step One describes the zone hydrogen sulfide exclusion area maps, defining when reporting is to be used (based on well location and distance from inhabited areas). Step Two provides details of the recommended method for determining hydrogen sulfide release through a data search process. Step Three consists of a series of instructions in the use of geologic analogs, data editing and wellbore design to further refine the cumulative hydrogen sulfide release rate. Step Four contains information designed to assist in detailed geological and reservoir modeling. It is not necessary to use all four steps in all cases. The user, however, is advised to use sound engineering judgement and due diligence in the calculation decisions. Sample calculations are provided for a variety of different situations. Measurement techniques are described in an appendix. A completed example of an audit form is attached. 10 + 6 refs., tabs

  18. Operators guide: Atmospheric Release Advisory Capability (ARAC) site facility

    International Nuclear Information System (INIS)

    Lawver, B.S.

    1977-01-01

    In this report capabilities and services are described for the Atmospheric Release Advisory Capability (ARAC). The ARAC site system and its operating procedures and interactions with the ARAC central facility located at LLL is outlined. ARAC is designed to help officials at designated ERDA sites and other locations in estimating the effects of atmospheric releases of radionuclides or other hazardous materials by issuing real-time advisories to guide them in their planning

  19. Operators guide: Atmospheric Release Advisory Capability (ARAC) site facility

    International Nuclear Information System (INIS)

    Cassaro, E.; Lomonaco, L.

    1979-01-01

    The Atmospheric Release Advisory Capability (ARAC) is designed to help officials at designated DOE sites and other locations in estimating the effects of atmospheric releases of radionuclides or other hazardous materials by issuing real-time advisories to guide them in their planning. This report outlines the capabilities and sources of ARAC, and in more detail describes an ARAC Site Facility, its operating procedures and interactions with the ARAC Central Facility (ACF) located at LLL

  20. Release of CFC-11 from disposal of polyurethane foam waste

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Jensen, M.H.

    2001-01-01

    The halocarbon CFC-11 has extensively been used as a blowing agent for polyurethane (PUR) insulation foams in home appliances and for residential and industrial construction. Release of CFCs is an important factor in the depletion of the ozone layer. For CFC-11 the future atmospheric concentrations...... will mainly depend on the continued release from PUR foams. Little is known about rates and time frames of the CFC release from foams especially after treatment and disposal of foam containing waste products. The CFC release is mainly controlled by slow diffusion out through the PUR. From the literature...... and by reevaluation of an old reported experiment, diffusion coefficients in the range of 0.05-1.7.10(-14) m(2) s(-1) were found reflecting differences in foam properties and experimental designs. Laboratory experiments studying the distribution of CFC in the foam and the short-term releases after shredding showed...

  1. Readily releasable pool of synaptic vesicles measured at single synaptic contacts.

    Science.gov (United States)

    Trigo, Federico F; Sakaba, Takeshi; Ogden, David; Marty, Alain

    2012-10-30

    To distinguish between different models of vesicular release in brain synapses, it is necessary to know the number of vesicles of transmitter that can be released immediately at individual synapses by a high-calcium stimulus, the readily releasable pool (RRP). We used direct stimulation by calcium uncaging at identified, single-site inhibitory synapses to investigate the statistics of vesicular release and the size of the RRP. Vesicular release, detected as quantal responses in the postsynaptic neuron, showed an unexpected stochastic variation in the number of quanta from stimulus to stimulus at high intracellular calcium, with a mean of 1.9 per stimulus and a maximum of three or four. The results provide direct measurement of the RRP at single synaptic sites. They are consistent with models in which release proceeds from a small number of vesicle docking sites with an average occupancy around 0.7.

  2. A PC parallel port button box provides millisecond response time accuracy under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  3. Multi-kinetics and site-specific release of gabapentin and flurbiprofen from oral fixed-dose combination: in vitro release and in vivo food effect.

    Science.gov (United States)

    Sonvico, Fabio; Conti, Chiara; Colombo, Gaia; Buttini, Francesca; Colombo, Paolo; Bettini, Ruggero; Barchielli, Marco; Leoni, Barbara; Loprete, Luca; Rossi, Alessandra

    2017-09-28

    In this work, a fixed-dose combination of gabapentin and flurbiprofen formulated as multilayer tablets has been designed, developed and studied in vitro and in vivo. The aim was to construct a single dosage form of the two drugs, able to perform a therapeutic program involving three release kinetics and two delivery sites, i.e., immediate release of gabapentin, intra-gastric prolonged release of gabapentin and intestinal (delayed) release of flurbiprofen. An oblong three-layer tablet was manufactured having as top layer a floating hydrophilic polymeric matrix for gastric release of gabapentin, as middle layer a disintegrating formulation for immediate release of a gabapentin loading dose and as bottom layer, an uncoated hydrophilic polymeric matrix, swellable but insoluble in gastric fluids, for delayed and prolonged release of flurbiprofen in intestinal environment. The formulations were studied in vitro and in vivo in healthy volunteers. The in vitro release rate assessment confirmed the programmed delivery design. A significant higher bioavailability of gabapentin administered 30min after meal, compared to fasting conditions or to dose administration 10min before meal, argued in favor of the gastro-retention of gabapentin prolonged release layer. The two drugs were delivered at different anatomical sites, since the food presence prolonged the gastric absorption of gabapentin from the floating layer and delayed the flurbiprofen absorption. The attainment of a successful delayed release of flurbiprofen was realized by a matrix based on a polymers' combination. The combined use of three hydrophilic polymers with different pH sensitivity provided the dosage form layer containing flurbiprofen with gastro-resistant characteristics without the use of film coating. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Effect of Nisin's Controlled Release on Microbial Growth as Modeled for Micrococcus luteus.

    Science.gov (United States)

    Balasubramanian, Aishwarya; Lee, Dong Sun; Chikindas, Michael L; Yam, Kit L

    2011-06-01

    The need for safe food products has motivated food scientists and industry to find novel technologies for antimicrobial delivery for improving food safety and quality. Controlled release packaging is a novel technology that uses the package to deliver antimicrobials in a controlled manner and sustain antimicrobial stress on the targeted microorganism over the required shelf life. This work studied the effect of controlled release of nisin to inhibit growth of Micrococcus luteus (a model microorganism) using a computerized syringe pump system to mimic the release of nisin from packaging films which was characterized by an initially fast rate and a slower rate as time progressed. The results show that controlled release of nisin was strikingly more effective than instantly added ("formulated") nisin. While instant addition experiments achieved microbial inhibition only at the beginning, controlled release experiments achieved complete microbial inhibition for a longer time, even when as little as 15% of the amount of nisin was used as compared to instant addition.

  5. The release of elements from dental casting alloy into cell-culture medium and artificial saliva.

    Science.gov (United States)

    Can, Gülşen; Akpınar, Gül; Aydın, Ahmet

    2007-04-01

    The biocompatibility of dental casting alloys is a critical issue because these alloys are in long-term intimate contact with oral tissues. Since the biocompatibility of alloys is not completely known; the release of elements from the alloys has been studied. The aim of this study was to compare the elemental release from dental casting alloy during exposure to artificial saliva and cell-culture medium. Twenty specimens made from Ni-Cr alloy were provided in the form of 5 mm diameter discs, 2 mm in thickness with a 7 mm stem attached to one face to facilitate handling. Ten of twenty samples were polished separately using a conventional technique. The remaining ten samples were left sandblasted with 50 mum Al(2)0(3). Ten samples (5 polished, 5 sandblasted) were separately placed into cell-culture wells with Dulbecco's Modified Eagle's Medium. The other ten samples were placed separately into cell-culture wells with artificial saliva. The samples were subjected in contact with these medium for 30 days. These medium were collected every 7 days. The cell-culture medium and artificial saliva without alloy samples were subjected to elemental analyses as a control. At the end of the exposure time, Atomic Absorption Spectrometry (AAS) was used to determine the release of elements from the alloys into all collected medium. Statistical analyses were assessed with two-way ANOVA. In general, the elemental release occurred with in all medium. The elemental releases of sandblasted alloys were higher than polished alloys. Artificial saliva was found to cause more release from the samples. In both media, Ni released from polished and sandblasted alloys were higher than Cr and Mo. The results suggest that the release of elements from the alloys might have correlated with the environments and the surface of dental alloy.

  6. Controlled release of bioactive PDGF-AA from a hydrogel/nanoparticle composite.

    Science.gov (United States)

    Elliott Donaghue, Irja; Shoichet, Molly S

    2015-10-01

    Polymer excipients, such as low molar mass poly(ethylene glycol) (PEG), have shown contradictory effects on protein stability when co-encapsulated in polymeric nanoparticles. To gain further insight into these effects, platelet-derived growth factor (PDGF-AA) was encapsulated in polymeric nanoparticles with vs. without PEG. PDGF-AA is a particularly compelling protein, as it has been demonstrated to promote cell survival and induce the oligodendrocyte differentiation of neural stem/progenitor cells (NSPCs) both in vitro and in vivo. Here we show, for the first time, the controlled release of bioactive PDGF-AA from an injectable nanoparticle/hydrogel drug delivery system (DDS). PDGF-AA was encapsulated, with high efficiency, in poly(lactide-co-glycolide) nanoparticles, and its release from the drug delivery system was followed over 21 d. Interestingly, the co-encapsulation of low molecular weight poly(ethylene glycol) increased the PDGF-AA loading but, unexpectedly, accelerated the aggregation of PDGF-AA, resulting in reduced activity and detection by enzyme-linked immunosorbent assay (ELISA). In the absence of PEG, released PDGF-AA remained bioactive as demonstrated with NSPC oligodendrocyte differentiation, similar to positive controls, and significantly different from untreated controls. This work presents a novel delivery method for differentiation factors, such as PDGF-AA, and provides insights into the contradictory effects reported in the literature of excipients, such as PEG, on the loading and release of proteins from polymeric nanoparticles. Previously, the polymer poly(ethylene glycol) (PEG) has been used in many biomaterials applications, from surface coatings to the encapsulation of proteins. In this work, we demonstrate that, unexpectedly, low molecular weight PEG has a deleterious effect on the release of the encapsulated protein platelet-derived growth factor AA (PDGF-AA). We also demonstrate release of bioactive PDGF-AA (in the absence of PEG

  7. Understanding release kinetics of biopolymer drug delivery microcapsules for biomedical applications

    International Nuclear Information System (INIS)

    Desai, Salil; Perkins, Jessica; Harrison, Benjamin S.; Sankar, Jag

    2010-01-01

    Drug delivery and dosage concentrations are considered as major focal points in conventional as well as battlefield emergency medicine. The concept of localizing drug delivery via microcapsules is an evolving field to confine the adverse side effects of high concentration drug doses. This paper focuses on understanding release kinetics through biopolymer microcapsules for time-dependent drug release. Calcium alginate microcapsules were manufactured using a direct-write inkjet technique. Rhodamine 6G was used as the release agent to observe the release kinetics from calcium alginate beads in distilled water. A design of experiments was constructed to compare the effect of the microcapsule diameter and different concentrations of calcium chloride (M) and sodium alginate (%, w/v) solutions on the release kinetics profiles of the microcapsules. This research gives insight to identify favorable sizes of microcapsules and concentrations of sodium alginate and calcium chloride solutions for controlled release behavior of drug delivery microcapsules.

  8. Evaluation of Controlled Release Urea on the Dynamics of Nitrate, Ammonium, and Its Nitrogen Release in Black Soils of Northeast China

    Directory of Open Access Journals (Sweden)

    Xin Tong

    2018-01-01

    Full Text Available Controlled release urea (CRU is considered to enhance crop yields while alleviating negative environmental problems caused by the hazardous gas emissions that are associated with high concentrations of ammonium (NH4+ and nitrate (NO3− in black soils. Short-term effects of sulfur-coated urea (SCU and polyurethane-coated urea (PCU, compared with conventional urea, on NO3− and NH4+ in black soils were studied through the buried bag experiment conducted in an artificial climate chamber. We also investigated nitrogen (N release kinetics of CRU and correlations between the cumulative N release rate and concentrations of NO3− and NH4+. CRU can reduce concentrations of NO3− and NH4+, and PCU was more effective in maintaining lower soil NO3−/NH4+ ratios than SCU and U. Parabolic equation could describe the kinetics of NO3− and NH4+ treated with PCU. The Elovich equation could describe the kinetics of NO3− and NH4+ treated with SCU. The binary linear regression model was established to predict N release from PCU because of significant correlations between the cumulative N release rate and concentrations of NO3− and NH4+. These results provided a methodology and data support for characterizing and predicting the N release from PCU in black soils.

  9. Development of Real-Time Coal Monitoring Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Rajan Gurjar, Ph.D.

    2010-06-17

    Relying on coal for energy requires optimizing the extraction of heat content from various blends of coal fuel and reducing harmful constituents and byproducts. Having a real-time measurement instrument provides relevant information about toxic constituents released in the atmosphere from burning coal and optimizes the performance of a power plant. A few commercial instruments exist and have been in operation for more than a decade. However, most of these instruments are based on radioactive sources and are bulky, expensive and time-consuming. The proposed instrument is based on the Laser Induced Breakdown Spectroscopy (LIBS). The advantage of LIBS is that it is a standoff instrument, does not require sample preparation and provides precise information about sample constituents.

  10. Subtask 1.16-Slow-Release Bioremediation Accelerators

    International Nuclear Information System (INIS)

    Marc D. Kurz; Edwin S. Olson

    2006-01-01

    Low-cost methods are needed to enhance various bioremediation technologies, from natural attenuation to heavily engineered remediation of subsurface hydrocarbon contamination. Many subsurface sites have insufficient quantities of nitrogen and phosphorus, resulting in poor bioactivity and increased remediation time and costs. The addition of conventional fertilizers can improve bioactivity, but often the nutrients dissolve quickly and migrate away from the contaminant zone before being utilized by the microbes. Through this project, conducted by the Energy and Environmental Research Center, polymers were developed that slowly release nitrogen and phosphorus into the subsurface. Conceptually, these polymers are designed to adhere to soil particles in the subsurface contamination zone where they slowly degrade and release nutrients over longer periods of time compared to conventional fertilizer applications. Tests conducted during this study indicate that some of the developed polymers have excellent potential to satisfy the microbial requirements for enhanced bioremediation

  11. Subtask 1.16-Slow-Release Bioremediation Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Marc D. Kurz; Edwin S. Olson

    2006-07-31

    Low-cost methods are needed to enhance various bioremediation technologies, from natural attenuation to heavily engineered remediation of subsurface hydrocarbon contamination. Many subsurface sites have insufficient quantities of nitrogen and phosphorus, resulting in poor bioactivity and increased remediation time and costs. The addition of conventional fertilizers can improve bioactivity, but often the nutrients dissolve quickly and migrate away from the contaminant zone before being utilized by the microbes. Through this project, conducted by the Energy & Environmental Research Center, polymers were developed that slowly release nitrogen and phosphorus into the subsurface. Conceptually, these polymers are designed to adhere to soil particles in the subsurface contamination zone where they slowly degrade and release nutrients over longer periods of time compared to conventional fertilizer applications. Tests conducted during this study indicate that some of the developed polymers have excellent potential to satisfy the microbial requirements for enhanced bioremediation.

  12. Biosensor cell assay for measuring real-time aldosterone-induced release of histamine from mesenteric arteries

    DEFF Research Database (Denmark)

    Dalgaard, Emil G; Andersen, Kenneth; Svenningsen, Per

    2017-01-01

    as a sensitive biosensor assay for histamine release from isolated mouse mesenteric arteries. Activation of the H1 receptor by histamine was measured as an increased number of intracellular Ca(2+) transient peaks using fluorescence imaging RESULTS: The developed biosensor was sensitive to histamine...... in physiological relevant concentrations and responded to substances released by the artery preparation. Aldosterone treatment of mesenteric arteries from wild type mice for 50 minutes resulted in an increased number of intracellular Ca(2+) transient peaks in the biosensor cells, which was significantly inhibited...... by the histamine H1 blocker pyrilamine. Mesenteric arteries from mast cell deficient SASH mice induced similar pyrilamine-sensitive Ca(2+) transient response in the biosensor cells. Mesenteric arteries from wild type and SASH mice expressed histamine decarboxylase mRNA, indicating that mast cells are not the only...

  13. Savannah River Site radioiodine atmospheric releases and offsite maximum doses

    International Nuclear Information System (INIS)

    Marter, W.L.

    1990-01-01

    Radioisotopes of iodine have been released to the atmosphere from the Savannah River Site since 1955. The releases, mostly from the 200-F and 200-H Chemical Separations areas, consist of the isotopes, I-129 and 1-131. Small amounts of 1-131 and 1-133 have also been released from reactor facilities and the Savannah River Laboratory. This reference memorandum was issued to summarize our current knowledge of releases of radioiodines and resultant maximum offsite doses. This memorandum supplements the reference memorandum by providing more detailed supporting technical information. Doses reported in this memorandum from consumption of the milk containing the highest I-131 concentration following the 1961 1-131 release incident are about 1% higher than reported in the reference memorandum. This is the result of using unrounded 1-131 concentrations of I-131 in milk in this memo. It is emphasized here that this technical report does not constitute a dose reconstruction in the same sense as the dose reconstruction effort currently underway at Hanford. This report uses existing published data for radioiodine releases and existing transport and dosimetry models

  14. Multi-purposable filaments of HPMC for 3D printing of medications with tailored drug release and timed-absorption.

    Science.gov (United States)

    Kadry, Hossam; Al-Hilal, Taslim A; Keshavarz, Ali; Alam, Farzana; Xu, Changxue; Joy, Abraham; Ahsan, Fakhrul

    2018-04-20

    Three-dimensional printing (3DP), though developed for nonmedical applications and once regarded as futuristic only, has recently been deployed for the fabrication of pharmaceutical products. However, the existing feeding materials (inks and filaments) that are used for printing drug products have various shortcomings, including the lack of biocompatibility, inadequate extrudability and printability, poor drug loading, and instability. Here, we have sought to develop a filament using a single pharmaceutical polymer, with no additives, which can be multi-purposed and manipulated by computational design for the preparation of tablets with desired release and absorption patterns. As such, we have used hydroxypropyl-methylcellulose (HPMC) and diltiazem, a model drug, to prepare both drug-free and drug-impregnated filaments, and investigated their thermal and crystalline properties, studied the cytotoxicity of the filaments, designed and printed tablets with various infill densities and patterns. By alternating the drug-free and drug-impregnated filaments, we fabricated various types of tablets, studied the drug release profiles, and assessed oral absorption in rats. Both diltiazem and HPMC were stable at extrusion and printing temperatures, and the drug loading was 10% (w/w). The infill density, as well as infill patterns, influenced the drug release profile, and thus, when the infill density was increased to 100%, the percentage of drug released dramatically declined. Tablets with alternating drug-free and drug-loaded layers showed delayed and intermittent drug release, depending on when the drug-loaded layers encountered the dissolution media. Importantly, the oral absorption patterns accurately reproduced the drug release profiles and showed immediate, extended, delayed and episodic absorption of the drug from the rat gastrointestinal tract (GIT). Overall, we have demonstrated here that filaments for 3D printers can be prepared from a pharmaceutical polymer with no

  15. A reappraisal of drug release laws using Monte Carlo simulations: the prevalence of the Weibull function.

    Science.gov (United States)

    Kosmidis, Kosmas; Argyrakis, Panos; Macheras, Panos

    2003-07-01

    To verify the Higuchi law and study the drug release from cylindrical and spherical matrices by means of Monte Carlo computer simulation. A one-dimensional matrix, based on the theoretical assumptions of the derivation of the Higuchi law, was simulated and its time evolution was monitored. Cylindrical and spherical three-dimensional lattices were simulated with sites at the boundary of the lattice having been denoted as leak sites. Particles were allowed to move inside it using the random walk model. Excluded volume interactions between the particles was assumed. We have monitored the system time evolution for different lattice sizes and different initial particle concentrations. The Higuchi law was verified using the Monte Carlo technique in a one-dimensional lattice. It was found that Fickian drug release from cylindrical matrices can be approximated nicely with the Weibull function. A simple linear relation between the Weibull function parameters and the specific surface of the system was found. Drug release from a matrix, as a result of a diffusion process assuming excluded volume interactions between the drug molecules, can be described using a Weibull function. This model, although approximate and semiempirical, has the benefit of providing a simple physical connection between the model parameters and the system geometry, which was something missing from other semiempirical models.

  16. Model for Microcapsule Drug Release with Ultrasound-Activated Enhancement.

    Science.gov (United States)

    Tsao, Nadia H; Hall, Elizabeth A H

    2017-11-14

    Microbubbles and microcapsules of silane-polycaprolactone (SiPCL) have been filled with a fluorescent acridium salt (lucigenin) as a model for a drug-loaded delivery vehicle. The uptake and delivery were studied and compared with similar microbubbles and microcapsules of silica/mercaptosilica (S/M/S). Positively charged lucigenin was encapsulated through an electrostatic mechanism, following a Type I Langmuir isotherm as expected, but with an additional multilayer uptake that leads to a much higher loading for the SiPCL system (∼280 μg/2.4 × 10 9 microcapsules compared with ∼135 μg/2.4 × 10 9 microcapsules for S/M/S). Whereas the lucigenin release from the S/M/S bubbles and capsules loaded below the solubility limit is consistent with diffusion from a monolithic structure, the SiPCL structures show distinct release patterns; the Weibull function predicts a general trend for diffusion from normal Euclidean space at short times tending toward diffusion out of fractal spaces with increasing time. As a slow release system, the dissolution time (T d ) increases from 1 to 2 days for the S/M/S and for the low concentration, loaded SiPCl vehicles to ∼10 days for the high loaded microcapsules. However, T d can be reduced on insonation to 2 days, indicating the potential to gain control over the local enhanced release with ultrasound. This was tested for a docetaxel model and its effect on C4-2B prostate cancer cells, showing improved cell toxicity for concentrations below the normal EC 50 in solution.

  17. Dynamic microvesicle release and clearance within the cardiovascular system: triggers and mechanisms.

    Science.gov (United States)

    Ayers, Lisa; Nieuwland, Rienk; Kohler, Malcolm; Kraenkel, Nicolle; Ferry, Berne; Leeson, Paul

    2015-12-01

    Interest in cell-derived microvesicles (or microparticles) within cardiovascular diagnostics and therapeutics is rapidly growing. Microvesicles are often measured in the circulation at a single time point. However, it is becoming clear that microvesicle levels both increase and decrease rapidly in response to certain stimuli such as hypoxia, acute cardiac stress, shear stress, hypertriglyceridaemia and inflammation. Consequently, the levels of circulating microvesicles will reflect the balance between dynamic mechanisms for release and clearance. The present review describes the range of triggers currently known to lead to microvesicle release from different cellular origins into the circulation. Specifically, the published data are used to summarize the dynamic impact of these triggers on the degree and rate of microvesicle release. Secondly, a summary of the current understanding of microvesicle clearance via different cellular systems, including the endothelial cell and macrophage, is presented, based on reported studies of clearance in experimental models and clinical scenarios, such as transfusion or cardiac stress. Together, this information can be used to provide insights into potential underlying biological mechanisms that might explain the increases or decreases in circulating microvesicle levels that have been reported and help to design future clinical studies. © 2015 Authors; published by Portland Press Limited.

  18. Electrospun Blank Nanocoating for Improved Sustained Release Profiles from Medicated Gliadin Nanofibers

    Directory of Open Access Journals (Sweden)

    Xinkuan Liu

    2018-03-01

    Full Text Available Nanomaterials providing sustained release profiles are highly desired for efficacious drug delivery. Advanced nanotechnologies are useful tools for creating elaborate nanostructure-based nanomaterials to achieve the designed functional performances. In this research, a modified coaxial electrospinning was explored to fabricate a novel core-sheath nanostructure (nanofibers F2, in which a sheath drug-free gliadin layer was successfully coated on the core ketoprofen (KET-gliadin nanocomposite. A monolithic nanocomposite (nanofibers F1 that was generated through traditional blending electrospinning of core fluid was utilized as a control. Scanning electron microscopy demonstrated that both nanofibers F1 and F2 were linear. Transmission electron microscopy verified that nanofibers F2 featured a clear core-sheath nanostructure with a thin sheath layer about 25 nm, whereas their cores and nanofibers F1 were homogeneous KET-gliadin nanocomposites. X-ray diffraction patterns verified that, as a result of fine compatibility, KET was dispersed in gliadin in an amorphous state. In vitro dissolution tests demonstrated that the thin blank nanocoating in nanofibers F2 significantly modified drug release kinetics from a traditional exponential equation of nanofibers F1 to a zero-order controlled release model, linearly freeing 95.7 ± 4.7% of the loaded cargoes over a time period of 16 h.

  19. Electrospun Blank Nanocoating for Improved Sustained Release Profiles from Medicated Gliadin Nanofibers.

    Science.gov (United States)

    Liu, Xinkuan; Shao, Wenyi; Luo, Mingyi; Bian, Jiayin; Yu, Deng-Guang

    2018-03-22

    Nanomaterials providing sustained release profiles are highly desired for efficacious drug delivery. Advanced nanotechnologies are useful tools for creating elaborate nanostructure-based nanomaterials to achieve the designed functional performances. In this research, a modified coaxial electrospinning was explored to fabricate a novel core-sheath nanostructure (nanofibers F2), in which a sheath drug-free gliadin layer was successfully coated on the core ketoprofen (KET)-gliadin nanocomposite. A monolithic nanocomposite (nanofibers F1) that was generated through traditional blending electrospinning of core fluid was utilized as a control. Scanning electron microscopy demonstrated that both nanofibers F1 and F2 were linear. Transmission electron microscopy verified that nanofibers F2 featured a clear core-sheath nanostructure with a thin sheath layer about 25 nm, whereas their cores and nanofibers F1 were homogeneous KET-gliadin nanocomposites. X-ray diffraction patterns verified that, as a result of fine compatibility, KET was dispersed in gliadin in an amorphous state. In vitro dissolution tests demonstrated that the thin blank nanocoating in nanofibers F2 significantly modified drug release kinetics from a traditional exponential equation of nanofibers F1 to a zero-order controlled release model, linearly freeing 95.7 ± 4.7% of the loaded cargoes over a time period of 16 h.

  20. In-vitro release of anti-proliferative paclitaxel from novel balloon-expandable polycaprolactone stents

    International Nuclear Information System (INIS)

    Liu, Shih-Jung; Hsiao, Chao-Ying; Chen, Jan-Kan; Liu, Kuo-Sheng; Lee, Cheng-Hung

    2011-01-01

    This report investigated the in-vitro release characteristics of paclitaxel from novel balloon-expandable polycaprolactone stents. Polycaprolactone stents were first manufactured by a lab-made micro-injection molding machine. Paclitaxel and polylactide-polyglycolide (PLGA) copolymer were dissolved in acetonitrile and were coated onto the surface of the stents by a spray coating device, which was designed and built especially for this study. An elution method was utilized to characterize the in-vitro release characteristics of paclitaxel. The high performance liquid chromatography (HPLC) analysis showed that biodegradable stents could provide sustained release of paclitaxel for more than 70 days. Various process parameters that controlled the release rate of paclitaxel were studied. The experimental results suggested that the total period of drug release could be prolonged by adopting 75:25 PLGA copolymers, employing multi-layer coatings, and increasing the drug loading. In addition, the effectiveness of eluted paclitaxel on cell behavior was examined. The results showed that the eluted drug could effectively inhibit the proliferation of smooth muscle cells. - Research Highlights: → We investigate the in-vitro release characteristics of paclitaxel from polycaprolactone stents. → Biodegradable stents provide sustained release of paclitaxel for more than 70 days. → The eluted drug effectively inhibits the proliferation of smooth muscle cells.