WorldWideScience

Sample records for providing high accuracy

  1. MALDI-TOF mass spectrometry provides high accuracy in identification of Salmonella at species level but is limited to type or subtype Salmonella serovars.

    Science.gov (United States)

    Kang, Lin; Li, Nan; Li, Ping; Zhou, Yang; Gao, Shan; Gao, Hongwei; Xin, Wenwen; Wang, Jinglin

    2017-04-01

    Salmonella can cause global foodborne illnesses in humans and many animals. The current diagnostic gold standard used for detecting Salmonella infection is microbiological culture followed by serological confirmation tests. However, these methods are complicated and time-consuming. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis offers some advantages in rapid identification, for example, simple and fast sample preparation, fast and automated measurement, and robust and reliable identification up to genus and species levels, possibly even to the strain level. In this study, we established a reference database for species identification using whole-cell MALDI-TOF MS; the database consisted of 12 obtained main spectra of the Salmonella culture collection strains belonged to seven serotypes. Eighty-two clinical isolates of Salmonella were identified using established database, and partial 16S rDNA gene sequencing and serological method were used as comparison. We found that MALDI-TOF mass spectrometry provided high accuracy in identification of Salmonella at species level but was limited to type or subtype Salmonella serovars. We also tried to find serovar-specific biomarkers and failed. Our study demonstrated that (a) MALDI-TOF MS was suitable for identification of Salmonella at species level with high accuracy and (b) that MALDI-TOF MS method presented in this study was not useful for serovar assignment of Salmonella currently, because of its low matching with serological method and (c) MALDI-TOF MS method presented in this study was not suitable to subtype S. typhimurium because of its low discriminatory ability.

  2. Accuracy of marketing claims by providers of stereotactic radiation therapy.

    Science.gov (United States)

    Narang, Amol K; Lam, Edwin; Makary, Martin A; Deweese, Theodore L; Pawlik, Timothy M; Pronovost, Peter J; Herman, Joseph M

    2013-01-01

    Direct-to-consumer advertising by industry has been criticized for encouraging overuse of unproven therapies, but advertising by health care providers has not been as carefully scrutinized. Stereotactic radiation therapy is an emerging technology that has sparked controversy regarding the marketing campaigns of some manufacturers. Given that this technology is also being heavily advertised on the Web sites of health care providers, the accuracy of providers' marketing claims should be rigorously evaluated. We reviewed the Web sites of all U.S. hospitals and private practices that provide stereotactic radiation using two leading brands of stereotactic radiosurgery technology. Centers were identified by using data from the manufacturers. Centers without Web sites were excluded. The final study population consisted of 212 centers with online advertisements for stereotactic radiation. Web sites were evaluated for advertisements that were inconsistent with advertising guidelines provided by the American Medical Association. Most centers (76%) had individual pages dedicated to the marketing of their brand of stereotactic technology that frequently contained manufacturer-authored images (50%) or text (55%). Advertising for the treatment of tumors that have not been endorsed by professional societies was present on 66% of Web sites. Centers commonly claimed improved survival (22%), disease control (20%), quality of life (17%), and toxicity (43%) with stereotactic radiation. Although 40% of Web sites championed the center's regional expertise in delivering stereotactic treatments, only 15% of Web sites provided data to support their claims. Provider advertisements for stereotactic radiation were prominent and aggressive. Further investigation of provider advertising, its effects on quality of care, and potential oversight mechanisms is needed.

  3. Accuracy of Marketing Claims by Providers of Stereotactic Radiation Therapy

    Science.gov (United States)

    Narang, Amol K.; Lam, Edwin; Makary, Martin A.; DeWeese, Theodore L.; Pawlik, Timothy M.; Pronovost, Peter J.; Herman, Joseph M.

    2013-01-01

    Purpose: Direct-to-consumer advertising by industry has been criticized for encouraging overuse of unproven therapies, but advertising by health care providers has not been as carefully scrutinized. Stereotactic radiation therapy is an emerging technology that has sparked controversy regarding the marketing campaigns of some manufacturers. Given that this technology is also being heavily advertised on the Web sites of health care providers, the accuracy of providers' marketing claims should be rigorously evaluated. Methods: We reviewed the Web sites of all US hospitals and private practices that provide stereotactic radiation using two leading brands of stereotactic radiosurgery technology. Centers were identified by using data from the manufacturers. Centers without Web sites were excluded. The final study population consisted of 212 centers with online advertisements for stereotactic radiation. Web sites were evaluated for advertisements that were inconsistent with advertising guidelines provided by the American Medical Association. Results: Most centers (76%) had individual pages dedicated to the marketing of their brand of stereotactic technology that frequently contained manufacturer-authored images (50%) or text (55%). Advertising for the treatment of tumors that have not been endorsed by professional societies was present on 66% of Web sites. Centers commonly claimed improved survival (22%), disease control (20%), quality of life (17%), and toxicity (43%) with stereotactic radiation. Although 40% of Web sites championed the center's regional expertise in delivering stereotactic treatments, only 15% of Web sites provided data to support their claims. Conclusion: Provider advertisements for stereotactic radiation were prominent and aggressive. Further investigation of provider advertising, its effects on quality of care, and potential oversight mechanisms is needed. PMID:23633973

  4. High Accuracy Transistor Compact Model Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hembree, Charles E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Mar, Alan [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Robertson, Perry J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspond- ingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantifi- cation of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transis- tors have been developed and are described in this report.

  5. High accuracy 3-D laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a mono-static staring 3-D laser radar based on gated viewing with range accuracy below 1 m at 10 m and 1 cm at 100. We use a high sensitivity, fast, intensified CCD camera, and a Nd:Yag passively Q-switched 32.4 kHz pulsed green laser at 532 nm. The CCD has 752x582 pixels. Camer...

  6. STRAP IV - High accuracy, low drift attitude control system.

    Science.gov (United States)

    Shrewsberry, D. J.; Budney, T. J.; Riley, D. C.; Schuler, B. C.

    1973-01-01

    The STRAP IV attitude control system was designed, tested, and successfully launched to provide stable high accuracy pointing at nontrackable X-ray sources. On its initial flight (May 19, 1972), the STRAP IV control system updated its high accuracy, rate integrating gyros on two successive stellar targets and then maneuvered the rocket body to point the experimental payload at two separate X-ray sources and an X-ray-free background location. The third axis, which remained under the control of a coarse free gyro, was updated by a technique of successive star-target coordinate transformation to ensure the correct fine-axis azimuth alignment for the high accuracy inertial maneuvers. Pointing accuracies of 4 arc min with limit cycle stability of less than 20 arc sec peak to peak were obtained on all targets.

  7. HEAT: High accuracy extrapolated ab initio thermochemistry.

    Science.gov (United States)

    Tajti, Attila; Szalay, Péter G; Császár, Attila G; Kállay, Mihály; Gauss, Jürgen; Valeev, Edward F; Flowers, Bradley A; Vázquez, Juana; Stanton, John F

    2004-12-15

    A theoretical model chemistry designed to achieve high accuracy for enthalpies of formation of atoms and small molecules is described. This approach is entirely independent of experimental data and contains no empirical scaling factors, and includes a treatment of electron correlation up to the full coupled-cluster singles, doubles, triples and quadruples approach. Energies are further augmented by anharmonic zero-point vibrational energies, a scalar relativistic correction, first-order spin-orbit coupling, and the diagonal Born-Oppenheimer correction. The accuracy of the approach is assessed by several means. Enthalpies of formation (at 0 K) calculated for a test suite of 31 atoms and molecules via direct calculation of the corresponding elemental formation reactions are within 1 kJ mol(-1) to experiment in all cases. Given the quite different bonding environments in the product and reactant sides of these reactions, the results strongly indicate that even greater accuracy may be expected in reactions that preserve (either exactly or approximately) the number and types of chemical bonds. (c) 2004 American Institute of Physics

  8. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  9. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate

  10. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1998-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with realtime information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate flight

  11. Accuracy Enhancement of Inertial Sensors Utilizing High Resolution Spectral Analysis

    Directory of Open Access Journals (Sweden)

    Michael Korenberg

    2012-08-01

    Full Text Available In both military and civilian applications, the inertial navigation system (INS and the global positioning system (GPS are two complementary technologies that can be integrated to provide reliable positioning and navigation information for land vehicles. The accuracy enhancement of INS sensors and the integration of INS with GPS are the subjects of widespread research. Wavelet de-noising of INS sensors has had limited success in removing the long-term (low-frequency inertial sensor errors. The primary objective of this research is to develop a novel inertial sensor accuracy enhancement technique that can remove both short-term and long-term error components from inertial sensor measurements prior to INS mechanization and INS/GPS integration. A high resolution spectral analysis technique called the fast orthogonal search (FOS algorithm is used to accurately model the low frequency range of the spectrum, which includes the vehicle motion dynamics and inertial sensor errors. FOS models the spectral components with the most energy first and uses an adaptive threshold to stop adding frequency terms when fitting a term does not reduce the mean squared error more than fitting white noise. The proposed method was developed, tested and validated through road test experiments involving both low-end tactical grade and low cost MEMS-based inertial systems. The results demonstrate that in most cases the position accuracy during GPS outages using FOS de-noised data is superior to the position accuracy using wavelet de-noising.

  12. Two blackbody radiometers of high accuracy.

    Science.gov (United States)

    Kendall, J M; Berdahl, C M

    1970-05-01

    Two cavity-type radiometers have been developed, based on first principles, having the capability of measuring an irradiance with an indicated error 0.3%. The prerequisites for this accuracy are a measuredaperture area, a measurement of electric voltages, and an effective absorptance of its blackbody cavity from 0.998 to 0.999 throughout the uv, visible, and ir spectral ranges. The first cavity-type radiometer is designed to operate only in a vacuum of radiometer in an evacuated cold chamber, an experimental determination of the Stefan-Boltzmann constant is obtained at a value that differs from the theoretical value by 0.3%, which indicates the degree of confidence that can be expected in measurements made with blackbody cavity radiometers. The second type of radiometer is designed to operate in either air or vacuum. Although its aperture opening is windowless, it is unaffected by wind. The range of intensities accurately measurable is from about 10 mW cm(-2) to 800 mW cm(-2); the indicated accuracy is also 0.3%.

  13. The effect of accuracy motivation on anchoring and adjustment: do people adjust from provided anchors?

    Science.gov (United States)

    Simmons, Joseph P; LeBoeuf, Robyn A; Nelson, Leif D

    2010-12-01

    Increasing accuracy motivation (e.g., by providing monetary incentives for accuracy) often fails to increase adjustment away from provided anchors, a result that has led researchers to conclude that people do not effortfully adjust away from such anchors. We challenge this conclusion. First, we show that people are typically uncertain about which way to adjust from provided anchors and that this uncertainty often causes people to believe that they have initially adjusted too far away from such anchors (Studies 1a and 1b). Then, we show that although accuracy motivation fails to increase the gap between anchors and final estimates when people are uncertain about the direction of adjustment, accuracy motivation does increase anchor-estimate gaps when people are certain about the direction of adjustment, and that this is true regardless of whether the anchors are provided or self-generated (Studies 2, 3a, 3b, and 5). These results suggest that people do effortfully adjust away from provided anchors but that uncertainty about the direction of adjustment makes that adjustment harder to detect than previously assumed. This conclusion has important theoretical implications, suggesting that currently emphasized distinctions between anchor types (self-generated vs. provided) are not fundamental and that ostensibly competing theories of anchoring (selective accessibility and anchoring-and-adjustment) are complementary. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  14. Operating a real time high accuracy positioning system

    Science.gov (United States)

    Johnston, G.; Hanley, J.; Russell, D.; Vooght, A.

    2003-04-01

    The paper shall review the history and development of real time DGPS services prior to then describing the design of a high accuracy GPS commercial augmentation system and service currently delivering over a wide area to users of precise positioning products. The infrastructure and system shall be explained in relation to the need for high accuracy and high integrity of positioning for users. A comparison of the different techniques for the delivery of data shall be provided to outline the technical approach taken. Examples of the performance of the real time system shall be shown in various regions and modes to outline the current achievable accuracies. Having described and established the current GPS based situation, a review of the potential of the Galileo system shall be presented. Following brief contextual information relating to the Galileo project, core system and services, the paper will identify possible key applications and the main user communities for sub decimetre level precise positioning. The paper will address the Galileo and modernised GPS signals in space that are relevant to commercial precise positioning for the future and will discuss the implications for precise positioning performance. An outline of the proposed architecture shall be described and associated with pointers towards a successful implementation. Central to this discussion will be an assessment of the likely evolution of system infrastructure and user equipment implementation, prospects for new applications and their effect upon the business case for precise positioning services.

  15. SHAPES - Spatial, high-accuracy, position-encoding sensor

    Science.gov (United States)

    Nerheim, Noble M.; Blue, Randel C.

    1992-01-01

    Future space systems will require control sensors capable of real-time measurements of position coordinates of many structural locations. Applications for such a sensor include figure and vibration control, rendezvous and docking, and structure assembly verification. The paper discusses an experimental study of SHAPES (spatial, high-accuracy, position-encoding sensor), a 3D position sensor that provides range and two angular positions of laser-illuminated retroreflector targets that mark the locations to be measured. Simultaneous range measurements to multiple targets by a time-of-flight corelation of short laser pulses are made with a CCD-equipped streak tube. Angular positions are measured with a CCD camera. Position measurements of 24 targets with sub-millimeter range accuracy at a 10 Hz update rate have been demonstrated.

  16. High speed high dynamic range high accuracy measurement system

    Science.gov (United States)

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  17. Compact, High Accuracy CO2 Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase I proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  18. Compact, High Accuracy CO2 Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase II proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  19. High-accuracy theoretical thermochemistry of fluoroethanes.

    Science.gov (United States)

    Nagy, Balázs; Csontos, Botond; Csontos, József; Szakács, Péter; Kállay, Mihály

    2014-07-03

    A highly accurate coupled-cluster-based ab initio model chemistry has been applied to calculate the thermodynamic functions including enthalpies of formation and standard entropies for fluorinated ethane derivatives, C2HxF6-x (x = 0-5), as well as ethane, C2H6. The invoked composite protocol includes contributions up to quadruple excitations in coupled-cluster (CC) theory as well as corrections beyond the nonrelativistic and Born-Oppenheimer approximations. For species CH2F-CH2F, CH2F-CHF2, and CHF2-CHF2, where anti/gauche isomerism occurs due to the hindered rotation around the C-C bond, conformationally averaged enthalpies and entropies at 298.15 K are also calculated. The results obtained here are in reasonable agreement with previous experimental and theoretical findings, and for all fluorinated ethanes except CH2FCH3 and C2F6 this study delivers the best available theoretical enthalpy and entropy estimates.

  20. High accuracy & long timescale light curves

    Directory of Open Access Journals (Sweden)

    Hodgkin S.

    2013-04-01

    Full Text Available We present a theoretical analysis of the optical light curves (LCs for short-period high-mass transiting extrasolar planet systems. Our method considers the primary transit, the secondary eclipse, and the overall phase shape of the LC between the occultations. Phase variations arise from (i reflected and thermally emitted light by the planet, (ii the ellipsoidal shape of the star due to the gravitational pull of the planet, and (iii the Doppler shift of the stellar light as the star orbits the center of mass of the system. Our full model of the out-of-eclipse variations contains information about the planetary mass, orbital eccentricity, the orientation of periastron and the planet's albedo. For a range of hypothetical systems we demonstrate that the ellipsoidal variations (ii. can be large enough to be distinguished from the remaining components and that this effect can be used to constrain the planet's mass. As an example we presend KOI-13b (candidate exoplanet system included in the September 2011 Kepler data release. The Kepler light curve shows both primary and secondary eclipses, as well as significant out-of-eclipse light curve variations. We model the relative contributions from (i thermal emission from the companion, (ii planetary reflected light, (iii doppler beaming, and (iv ellipsoidal variations in the host-star arising from the tidal distortion of the host star by its companion. Our analysis, based on the light curve alone, enables us to constrain the mass of the KOI-13.01 companion to be MC = 8.3 ± 1.25 MJ and thus demonstrates that the transiting companion is a planet. The teqnique is useful for current and future space missions such as Kepler and PLATO.

  1. High accuracy & long timescale light curves

    Science.gov (United States)

    Mislis, D.; Hodgkin, S.

    2013-04-01

    We present a theoretical analysis of the optical light curves (LCs) for short-period high-mass transiting extrasolar planet systems. Our method considers the primary transit, the secondary eclipse, and the overall phase shape of the LC between the occultations. Phase variations arise from (i) reflected and thermally emitted light by the planet, (ii) the ellipsoidal shape of the star due to the gravitational pull of the planet, and (iii) the Doppler shift of the stellar light as the star orbits the center of mass of the system. Our full model of the out-of-eclipse variations contains information about the planetary mass, orbital eccentricity, the orientation of periastron and the planet's albedo. For a range of hypothetical systems we demonstrate that the ellipsoidal variations (ii.) can be large enough to be distinguished from the remaining components and that this effect can be used to constrain the planet's mass. As an example we presend KOI-13b (candidate exoplanet system) included in the September 2011 Kepler data release. The Kepler light curve shows both primary and secondary eclipses, as well as significant out-of-eclipse light curve variations. We model the relative contributions from (i) thermal emission from the companion, (ii) planetary reflected light, (iii) doppler beaming, and (iv) ellipsoidal variations in the host-star arising from the tidal distortion of the host star by its companion. Our analysis, based on the light curve alone, enables us to constrain the mass of the KOI-13.01 companion to be MC = 8.3 ± 1.25 MJ and thus demonstrates that the transiting companion is a planet. The teqnique is useful for current and future space missions such as Kepler and PLATO.

  2. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units

    Directory of Open Access Journals (Sweden)

    Qingzhong Cai

    2016-06-01

    Full Text Available An inertial navigation system (INS has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10−6°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs using common turntables, has a great application potential in future atomic gyro INSs.

  3. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units.

    Science.gov (United States)

    Cai, Qingzhong; Yang, Gongliu; Song, Ningfang; Liu, Yiliang

    2016-06-22

    An inertial navigation system (INS) has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10(-6)°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs) using common turntables, has a great application potential in future atomic gyro INSs.

  4. Correlation between provider computer experience and accuracy of electronic anesthesia charting A pilot study and performance improvement project

    Science.gov (United States)

    2017-03-20

    Anesthesia recordkeeping: Accuracy of recall with computerized and manual entry recordkeeping. CORRELATION BETWEEN PROVIDER COMPUTER EXPERIENCE 39...Unexpected increased mortality after implementation of a CORRELATION BETWEEN PROVIDER COMPUTER EXPERIENCE 40 commercially sold computerized physician...Correlation between provider computer experience and accuracy of electronic anesthesia charting – A pilot study and performance improvement

  5. Stabilized high-accuracy optical tracking system (SHOTS)

    Science.gov (United States)

    Ruffatto, Donald; Brown, H. Donald; Pohle, Richard H.; Reiley, Michael F.; Haddock, Delmar D.

    2001-08-01

    This paper describes an 0.75 meter aperture, Stabilized High-accuracy Optical Tracking System (SHOTS), two of which are being developed by Textron Systems Corporation, under contract to the Navy's Space and Naval Warfare Systems Center, San Diego (SPAWAR-SD). The SHOTS design is optimized to meet the requirements of the Navy's Theater Ballistic Missile Defense (TBMD) testing program being conducted at the Kauai Pacific Missile Range Facility (PMRF). The SHOTS utilizes a high-precision, GPS aided inertial navigation unit (INU) coupled with a 3-axis, rate gyro stabilized mount which allows precision pointing to be achieved on either land or sea-based platforms. The SHOTS mount control system architecture, acquisition, tracking and pointing (ATP) functionality and methodology which allows the system to meet the TBMD mission data collection requirements are discussed. High frame rate visible and MWIR sensors are incorporated into the system design to provide the capability of capturing short duration events, e.g., missile-target intercepts. These sensors along with the supporting high speed data acquisition, recording and control subsystems are described. Simulations of the SHOTS imaging performance in TBMD measurement scenarios are presented along with an example of the image improvement being achieved with post-processing image reconstruction algorithms.

  6. High accuracy mantle convection simulation through modern numerical methods

    KAUST Repository

    Kronbichler, Martin

    2012-08-21

    Numerical simulation of the processes in the Earth\\'s mantle is a key piece in understanding its dynamics, composition, history and interaction with the lithosphere and the Earth\\'s core. However, doing so presents many practical difficulties related to the numerical methods that can accurately represent these processes at relevant scales. This paper presents an overview of the state of the art in algorithms for high-Rayleigh number flows such as those in the Earth\\'s mantle, and discusses their implementation in the Open Source code Aspect (Advanced Solver for Problems in Earth\\'s ConvecTion). Specifically, we show how an interconnected set of methods for adaptive mesh refinement (AMR), higher order spatial and temporal discretizations, advection stabilization and efficient linear solvers can provide high accuracy at a numerical cost unachievable with traditional methods, and how these methods can be designed in a way so that they scale to large numbers of processors on compute clusters. Aspect relies on the numerical software packages deal.II and Trilinos, enabling us to focus on high level code and keeping our implementation compact. We present results from validation tests using widely used benchmarks for our code, as well as scaling results from parallel runs. © 2012 The Authors Geophysical Journal International © 2012 RAS.

  7. A PC parallel port button box provides millisecond response time accuracy under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  8. Automatic, high-accuracy image registration in confocal microscopy.

    Science.gov (United States)

    Liu, Jian; Li, Yong; Wang, Weibo; Wang, Yuhang; Zhang, He; Tan, Jiubin

    2017-11-10

    We proposed a high-accuracy image registration method of confocal microscopy for a large field of view and high resolution. The spatial information (edge information) and the entropy correlation coefficient have been both taken into account for higher accuracy of registration. The edge information is introduced to calculate the normalization correlation coefficient of the image. Then the normalization correlation coefficient and the entropy correlation coefficient of the original image have been used to improve the proposed similarity measures, the normalized mutual information with edge information (called EMI). Meanwhile, a parallel particle swarm optimization (pa-PSO) with the idea of conditional initialization and parallel cooperation is developed to speed up the convergence rate and further reduce the mismatch. Experiments verified that the registration accuracy can be up to 0.2 pixel and has better robustness to the noise.

  9. High-accuracy polynomial solutions of the classical Stefan problem

    Science.gov (United States)

    Kot, V. A.

    2017-09-01

    High-accuracy polynomial solutions of the Stefan problem for a semi-infinite medium with Dirichlet and Neumann boundary conditions and boundary conditions of general form are presented. The initial temperature of the medium was assumed to be equal to its phase-transition temperature. With the use of the integral method of boundary characteristics, based on the multiple integration of the heat-conduction equation, sequences of identical equalities with different boundary conditions were obtained. On the basis of these equalities, polynomial solutions of different degrees were constructed. High efficiency of the approach proposed was demonstrated by different examples. The polynomial solutions of the second and third degrees surpass in approximation accuracy the analogous known solutions. The accuracy of the calculations of the interphase boundary with the use of the fourth- and fifth-degree polynomials is higher by several orders of magnitude then that of numerical methods.

  10. Accuracy of pediatric primary care providers' screening and referral for early childhood caries.

    Science.gov (United States)

    Pierce, Kate M; Rozier, R Gary; Vann, William F

    2002-05-01

    Tooth decay is one of the more common diseases of childhood. Slightly >40% of US children are already affected by the time they reach kindergarten. Primary care physicians can play an important role in prevention and control of this disease because of their ready access to this population. Unlike dentists, they see a large percentage of children during their infant and toddler years. However, few studies have been conducted on oral screenings and referrals by primary care physicians or the effectiveness of their oral health preventive activities. The purpose of this study was to determine the accuracy of pediatric primary care providers' screening and referral for Early Childhood Caries. We sought to compare independent, blinded oral screening results and referral recommendations made by primary care providers with those of a pediatric dentist, considered for purposes of the study to be the reference gold standard. The study was conducted at a private pediatric group practice in North Carolina. The practice was selected because it serves a large volume of Medicaid patients and includes a large number of pediatric primary care providers (11 pediatricians and 1 nurse practitioner). Study participants included Medicaid-eligible children younger than 36 months of age with erupted teeth. The pediatric primary care providers in this practice received 2 hours of training in infant oral health. The training consisted of a review of the study methods and clinical slides illustrating dental caries in various stages of progression. Specific instructions were given to the providers on how to recognize a cavitated carious lesion and how to determine when a dental referral is needed. Providers were instructed to refer any child with 1 or more cavitated carious lesions, soft tissue pathology, or evidence of trauma to the teeth or mouth. Before commencing the study, calibration and a comparative analysis were performed to establish reliability and validity of the examinations

  11. High Accuracy, Miniature Pressure Sensor for Very High Temperatures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — SiWave proposes to develop a compact, low-cost MEMS-based pressure sensor for very high temperatures and low pressures in hypersonic wind tunnels. Most currently...

  12. High-accuracy brain-machine interfaces using feedback information.

    Directory of Open Access Journals (Sweden)

    Hong Gi Yeom

    Full Text Available Sensory feedback is very important for movement control. However, feedback information has not been directly used to update movement prediction model in the previous BMI studies, although the closed-loop BMI system provides the visual feedback to users. Here, we propose a BMI framework combining image processing as the feedback information with a novel prediction method. The feedback-prediction algorithm (FPA generates feedback information from the positions of objects and modifies movement prediction according to the information. The FPA predicts a target among objects based on the movement direction predicted from the neural activity. After the target selection, the FPA modifies the predicted direction toward the target and modulates the magnitude of the predicted vector to easily reach the target. The FPA repeats the modification in every prediction time points. To evaluate the improvements of prediction accuracy provided by the feedback, we compared the prediction performances with feedback (FPA and without feedback. We demonstrated that accuracy of movement prediction can be considerably improved by the FPA combining feedback information. The accuracy of the movement prediction was significantly improved for all subjects (P<0.001 and 32.1% of the mean error was reduced. The BMI performance will be improved by combining feedback information and it will promote the development of a practical BMI system.

  13. A high-accuracy map of global terrain elevations

    Science.gov (United States)

    Yamazaki, Dai; Ikeshima, Daiki; Tawatari, Ryunosuke; Yamaguchi, Tomohiro; O'Loughlin, Fiachra; Neal, Jeffery C.; Sampson, Christopher C.; Kanae, Shinjiro; Bates, Paul D.

    2017-06-01

    Spaceborne digital elevation models (DEMs) are a fundamental input for many geoscience studies, but they still include nonnegligible height errors. Here we introduce a high-accuracy global DEM at 3″ resolution ( 90 m at the equator) by eliminating major error components from existing DEMs. We separated absolute bias, stripe noise, speckle noise, and tree height bias using multiple satellite data sets and filtering techniques. After the error removal, land areas mapped with ±2 m or better vertical accuracy were increased from 39% to 58%. Significant improvements were found in flat regions where height errors larger than topography variability, and landscapes such as river networks and hill-valley structures, became clearly represented. We found the topography slope of previous DEMs was largely distorted in most of world major floodplains (e.g., Ganges, Nile, Niger, and Mekong) and swamp forests (e.g., Amazon, Congo, and Vasyugan). The newly developed DEM will enhance many geoscience applications which are terrain dependent.

  14. High accuracy operon prediction method based on STRING database scores.

    Science.gov (United States)

    Taboada, Blanca; Verde, Cristina; Merino, Enrique

    2010-07-01

    We present a simple and highly accurate computational method for operon prediction, based on intergenic distances and functional relationships between the protein products of contiguous genes, as defined by STRING database (Jensen,L.J., Kuhn,M., Stark,M., Chaffron,S., Creevey,C., Muller,J., Doerks,T., Julien,P., Roth,A., Simonovic,M. et al. (2009) STRING 8-a global view on proteins and their functional interactions in 630 organisms. Nucleic Acids Res., 37, D412-D416). These two parameters were used to train a neural network on a subset of experimentally characterized Escherichia coli and Bacillus subtilis operons. Our predictive model was successfully tested on the set of experimentally defined operons in E. coli and B. subtilis, with accuracies of 94.6 and 93.3%, respectively. As far as we know, these are the highest accuracies ever obtained for predicting bacterial operons. Furthermore, in order to evaluate the predictable accuracy of our model when using an organism's data set for the training procedure, and a different organism's data set for testing, we repeated the E. coli operon prediction analysis using a neural network trained with B. subtilis data, and a B. subtilis analysis using a neural network trained with E. coli data. Even for these cases, the accuracies reached with our method were outstandingly high, 91.5 and 93%, respectively. These results show the potential use of our method for accurately predicting the operons of any other organism. Our operon predictions for fully-sequenced genomes are available at http://operons.ibt.unam.mx/OperonPredictor/.

  15. Generation of an Optimum High Speed High Accuracy Operational Amplifier.

    Science.gov (United States)

    1985-09-01

    certainly will have gains and emitter resistances that are not identical. In mono- lithic op-amps, it is highly desirable that all of the tran- sistors on a...external resistances ( a and K . altered). In general, w and Q are functions of a and K. p .p , "It is desirable to select these values such that the...220),OMEGA(220) COMPLEX HH,S,DENOM REAL K,ANUM c THE FOLLOWING ARE CONSTANTS TO BE UTILIZED:A01=>DC GAIN OF FIRST c OPAMP ;A02=>DC GAIN OF SECOND OPAMP

  16. Classification accuracy of claims-based methods for identifying providers failing to meet performance targets

    Science.gov (United States)

    Hubbard, Rebecca A.; Benjamin-Johnson, Rhondee; Onega, Tracy; Smith-Bindman, Rebecca; Zhu, Weiwei; Fenton, Joshua J.

    2014-01-01

    Summary Quality assessment is critical for healthcare reform but data sources are lacking for measurement of many important healthcare outcomes. With over 49 million people covered by Medicare as of 2010, Medicare claims data offer a potentially valuable source that could be used in targeted health care quality improvement efforts. However, little is known about the operating characteristics of provider profiling methods using claims-based outcome measures that may estimate provider performance with error. Motivated by the example of screening mammography performance, we compared approaches to identifying providers failing to meet guideline targets using Medicare claims data. We used data from the Breast Cancer Surveillance Consortium and linked Medicare claims to compare claims-based and clinical estimates of cancer detection rate. We then demonstrated the performance of claim-based estimates across a broad range of operating characteristics using simulation studies. We found that identification of poor performing providers was extremely sensitive to algorithm specificity, with no approach identifying more than 65% of poorly performing providers when claims-based measures had specificity of 0.995 or less. We conclude that claims have the potential to contribute important information on healthcare outcomes to quality improvement efforts. However, to achieve this potential, development of highly accurate claims-based outcome measures should remain a priority. PMID:25302935

  17. Can Providing Rubrics for Writing Tasks Improve Developing Writers' Calibration Accuracy?

    Science.gov (United States)

    Hawthorne, Katrice A.; Bol, Linda; Pribesh, Shana

    2017-01-01

    Rubric-referenced calibration and the interaction between writing achievement and calibration, a measure of the relationship between one's performance and the accuracy of one's judgments, were investigated. Undergraduate students (N = 596) were assigned to one of three calibration conditions: (a) global, (b) global and general criteria, or (c)…

  18. A high accuracy land use/cover retrieval system

    Directory of Open Access Journals (Sweden)

    Alaa Hefnawy

    2012-03-01

    Full Text Available The effects of spatial resolution on the accuracy of mapping land use/cover types have received increasing attention as a large number of multi-scale earth observation data become available. Although many methods of semi automated image classification of remotely sensed data have been established for improving the accuracy of land use/cover classification during the past 40 years, most of them were employed in single-resolution image classification, which led to unsatisfactory results. In this paper, we propose a multi-resolution fast adaptive content-based retrieval system of satellite images. Through our proposed system, we apply a Super Resolution technique for the Landsat-TM images to have a high resolution dataset. The human–computer interactive system is based on modified radial basis function for retrieval of satellite database images. We apply the backpropagation supervised artificial neural network classifier for both the multi and single resolution datasets. The results show significant improved land use/cover classification accuracy for the multi-resolution approach compared with those from single-resolution approach.

  19. Two high accuracy digital integrators for Rogowski current transducers

    Science.gov (United States)

    Luo, Pan-dian; Li, Hong-bin; Li, Zhen-hua

    2014-01-01

    The Rogowski current transducers have been widely used in AC current measurement, but their accuracy is mainly subject to the analog integrators, which have typical problems such as poor long-term stability and being susceptible to environmental conditions. The digital integrators can be another choice, but they cannot obtain a stable and accurate output for the reason that the DC component in original signal can be accumulated, which will lead to output DC drift. Unknown initial conditions can also result in integral output DC offset. This paper proposes two improved digital integrators used in Rogowski current transducers instead of traditional analog integrators for high measuring accuracy. A proportional-integral-derivative (PID) feedback controller and an attenuation coefficient have been applied in improving the Al-Alaoui integrator to change its DC response and get an ideal frequency response. For the special design in the field of digital signal processing, the improved digital integrators have better performance than analog integrators. Simulation models are built for the purpose of verification and comparison. The experiments prove that the designed integrators can achieve higher accuracy than analog integrators in steady-state response, transient-state response, and temperature changing condition.

  20. High-accuracy mass spectrometry for fundamental studies.

    Science.gov (United States)

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions.

  1. Improving the Accuracy of High-Order Nodal Transport Methods

    Energy Technology Data Exchange (ETDEWEB)

    Azmy, Y.Y.; Buscaglia, G.C.; Zamonsky, O.M.

    1999-09-27

    This paper outlines some recent advances towards improving the accuracy of neutron transport calculations using the Arbitrarily High Order Transport-Nodal (AHOT-N) Method. These advances consist of several contributions: (a) A formula for the spatial weights that allows for the polynomial order to be raised arbitrarily high without suffering adverse effects from round-off error; (b) A reconstruction technique for the angular flux, based upon a recursive formula, that reduces the pointwise error by one ordeq (c) An a posterior error indicator that estimates the true error and its distribution throughout the domain, so that it can be used for adaptively refining the approximation. Present results are mainly for ID, extension to 2D-3D is in progress.

  2. Improving the Accuracy of High-Order Nodal Transport Methods

    Energy Technology Data Exchange (ETDEWEB)

    Azmy, Y.Y.; Buscaglia, G.C.; Zamonsky, O.M.

    1999-09-27

    This paper outlines some recent advances towards improving the accuracy of neutron calculations using the Arbitrarily High Order Transport-Nodal (AHOT-N) Method. These transport advances consist of several contributions: (a) A formula for the spatial weights that allows for the polynomial order to be raised arbitrarily high without suffering from pollution from round-off, error; (b) A reconstruction technique for the angular flux, based upon a recursive formula, that reduces the pointwise error by one order; (c) An a posterior error indicator that estimates the true error and its distribution throughout the domain, so that it can be used for adaptively reftig the approximation. Present results are mainly for ID, extension to 2D-3D is in progress.

  3. Read-only high accuracy volume holographic optical correlator

    Science.gov (United States)

    Zhao, Tian; Li, Jingming; Cao, Liangcai; He, Qingsheng; Jin, Guofan

    2011-10-01

    A read-only volume holographic correlator (VHC) is proposed. After the recording of all of the correlation database pages by angular multiplexing, a stand-alone read-only high accuracy VHC will be separated from the VHC recording facilities which include the high-power laser and the angular multiplexing system. The stand-alone VHC has its own low power readout laser and very compact and simple structure. Since there are two lasers that are employed for recording and readout, respectively, the optical alignment tolerance of the laser illumination on the SLM is very sensitive. The twodimensional angular tolerance is analyzed based on the theoretical model of the volume holographic correlator. The experimental demonstration of the proposed read-only VHC is introduced and discussed.

  4. Design and analysis of a high-accuracy flexure hinge.

    Science.gov (United States)

    Liu, Min; Zhang, Xianmin; Fatikow, Sergej

    2016-05-01

    This paper designs and analyzes a new kind of flexure hinge obtained by using a topology optimization approach, namely, a quasi-V-shaped flexure hinge (QVFH). Flexure hinges are formed by three segments: the left and right segments with convex shapes and the middle segment with straight line. According to the results of topology optimization, the curve equations of profiles of the flexure hinges are developed by numerical fitting. The in-plane dimensionless compliance equations of the flexure hinges are derived based on Castigliano's second theorem. The accuracy of rotation, which is denoted by the compliance of the center of rotation that deviates from the midpoint, is derived. The equations for evaluating the maximum stresses are also provided. These dimensionless equations are verified by finite element analysis and experimentation. The analytical results are within 8% uncertainty compared to the finite element analysis results and within 9% uncertainty compared to the experimental measurement data. Compared with the filleted V-shaped flexure hinge, the QVFH has a higher accuracy of rotation and better ability of preserving the center of rotation position but smaller compliance.

  5. High-accuracy identification and bioinformatic analysis of in vivo protein phosphorylation sites in yeast

    DEFF Research Database (Denmark)

    Gnad, Florian; de Godoy, Lyris M F; Cox, Jürgen

    2009-01-01

    Protein phosphorylation is a fundamental regulatory mechanism that affects many cell signaling processes. Using high-accuracy MS and stable isotope labeling in cell culture-labeling, we provide a global view of the Saccharomyces cerevisiae phosphoproteome, containing 3620 phosphorylation sites ma...

  6. 76 FR 1126 - Wireless E911 Location Accuracy Requirements; E911 Requirements for IP-Enabled Service Providers

    Science.gov (United States)

    2011-01-07

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 20 Wireless E911 Location Accuracy Requirements; E911 Requirements for IP-Enabled Service Providers AGENCY: Federal Communications Commission. ACTION: Proposed rule; extension of comment...

  7. Neocentromeres Provide Chromosome Segregation Accuracy and Centromere Clustering to Multiple Loci along a Candida albicans Chromosome.

    Directory of Open Access Journals (Sweden)

    Laura S Burrack

    2016-09-01

    Full Text Available Assembly of kinetochore complexes, involving greater than one hundred proteins, is essential for chromosome segregation and genome stability. Neocentromeres, or new centromeres, occur when kinetochores assemble de novo, at DNA loci not previously associated with kinetochore proteins, and they restore chromosome segregation to chromosomes lacking a functional centromere. Neocentromeres have been observed in a number of diseases and may play an evolutionary role in adaptation or speciation. However, the consequences of neocentromere formation on chromosome missegregation rates, gene expression, and three-dimensional (3D nuclear structure are not well understood. Here, we used Candida albicans, an organism with small, epigenetically-inherited centromeres, as a model system to study the functions of twenty different neocentromere loci along a single chromosome, chromosome 5. Comparison of neocentromere properties relative to native centromere functions revealed that all twenty neocentromeres mediated chromosome segregation, albeit to different degrees. Some neocentromeres also caused reduced levels of transcription from genes found within the neocentromere region. Furthermore, like native centromeres, neocentromeres clustered in 3D with active/functional centromeres, indicating that formation of a new centromere mediates the reorganization of 3D nuclear architecture. This demonstrates that centromere clustering depends on epigenetically defined function and not on the primary DNA sequence, and that neocentromere function is independent of its distance from the native centromere position. Together, the results show that a neocentromere can form at many loci along a chromosome and can support the assembly of a functional kinetochore that exhibits native centromere functions including chromosome segregation accuracy and centromere clustering within the nucleus.

  8. Algorithm of control systems required accuracy providing under the undetermined external disturbances

    OpenAIRE

    Zbrutskyi, O.; Zagirska, I.; Stetsenko, T.

    2011-01-01

    New control algorithm and algorithm for providing required quality are defined. It based on comparison the forecast system condition, allowance conditions value, dynamic system properties and undetermined external disturbances compensation.

  9. A high-accuracy DCO with hybrid architecture

    Science.gov (United States)

    Sun, Yapeng; Zhao, Huidong; Qiao, Shushan; Hei, Yong; Zhang, Fuhai

    2017-07-01

    In this paper, a novel hybrid digital-controlled oscillator (DCO) is proposed, which is used to improve the accuracy of the all-digital clock generator without reference source. The DCO with hybrid architecture consists of two parts: DCO_high and DCO_low. The DCO_high decides the coarse output frequency of DCO, and adopts the cascade structure to decrease the area. The DCO_low adopts the chain structure with three-state buffer, and decides the fine output frequency of DCO. Compared with traditional cascade DCO, the proposed hybrid DCO features higher precision with less inherent delay. Therefore the clock generator can tolerate process, voltage and temperature (PVT) variation and meet the needs of different conditions. The DCO is designed in SMIC 180 nm CMOS process with 0.021 mm2 chip area. The output frequency is adjusted from 15-120 MHz. The frequency error is less than 0.83% at 25 MHz with 1.6-1.8 V supply voltage and 0-80 °C temperature variations in TT, FF, SS corners. Project supported by the National Natural Science Foundation of China (Nos. 61306025, 61474135).

  10. Monitoring techniques for high accuracy interference fit assembly processes

    Science.gov (United States)

    Liuti, A.; Vedugo, F. Rodriguez; Paone, N.; Ungaro, C.

    2016-06-01

    In the automotive industry, there are many assembly processes that require a high geometric accuracy, in the micrometer range; generally open-loop controllers cannot meet these requirements. This results in an increased defect rate and high production costs. This paper presents an experimental study of interference fit process, aimed to evaluate the aspects which have the most impact on the uncertainty in the final positioning. The press-fitting process considered, consists in a press machine operating with a piezoelectric actuator to press a plug into a sleeve. Plug and sleeve are designed and machined to obtain a known interference fit. Differential displacement and velocity measurements of the plug with respect to the sleeve are measured by a fiber optic differential laser Doppler vibrometer. Different driving signals of the piezo actuator allow to have an insight into the differences between a linear and a pulsating press action. The paper highlights how the press-fit assembly process is characterized by two main phases: the first is an elastic deformation of the plug and sleeve, which produces a reversible displacement, the second is a sliding of the plug with respect to the sleeve, which results in an irreversible displacement and finally realizes the assembly. The simultaneous measurements of the displacement and the force have permitted to define characteristic features in the signal useful to identify the start of the irreversible movement. These indicators could be used to develop a control logic in a press assembly process.

  11. High accuracy magnetic field mapping of the LEP spectrometer magnet

    CERN Document Server

    Roncarolo, F

    2000-01-01

    The Large Electron Positron accelerator (LEP) is a storage ring which has been operated since 1989 at the European Laboratory for Particle Physics (CERN), located in the Geneva area. It is intended to experimentally verify the Standard Model theory and in particular to detect with high accuracy the mass of the electro-weak force bosons. Electrons and positrons are accelerated inside the LEP ring in opposite directions and forced to collide at four locations, once they reach an energy high enough for the experimental purposes. During head-to-head collisions the leptons loose all their energy and a huge amount of energy is concentrated in a small region. In this condition the energy is quickly converted in other particles which tend to go away from the interaction point. The higher the energy of the leptons before the collisions, the higher the mass of the particles that can escape. At LEP four large experimental detectors are accommodated. All detectors are multi purpose detectors covering a solid angle of alm...

  12. Determination of UAV position using high accuracy navigation platform

    Directory of Open Access Journals (Sweden)

    Ireneusz Kubicki

    2016-07-01

    Full Text Available The choice of navigation system for mini UAV is very important because of its application and exploitation, particularly when the installed on it a synthetic aperture radar requires highly precise information about an object’s position. The presented exemplary solution of such a system draws attention to the possible problems associated with the use of appropriate technology, sensors, and devices or with a complete navigation system. The position and spatial orientation errors of the measurement platform influence on the obtained SAR imaging. Both, turbulences and maneuvers performed during flight cause the changes in the position of the airborne object resulting in deterioration or lack of images from SAR. Consequently, it is necessary to perform operations for reducing or eliminating the impact of the sensors’ errors on the UAV position accuracy. You need to look for compromise solutions between newer better technologies and in the field of software. Keywords: navigation systems, unmanned aerial vehicles, sensors integration

  13. a Protocol for High-Accuracy Theoretical Thermochemistry

    Science.gov (United States)

    Welch, Bradley; Dawes, Richard

    2017-06-01

    Theoretical studies of spectroscopy and reaction dynamics including the necessary development of potential energy surfaces rely on accurate thermochemical information. The Active Thermochemical Tables (ATcT) approach by Ruscic^{1} incorporates data for a large number of chemical species from a variety of sources (both experimental and theoretical) and derives a self-consistent network capable of making extremely accurate estimates of quantities such as temperature dependent enthalpies of formation. The network provides rigorous uncertainties, and since the values don't rely on a single measurement or calculation, the provenance of each quantity is also obtained. To expand and improve the network it is desirable to have a reliable protocol such as the HEAT approach^{2} for calculating accurate theoretical data. Here we present and benchmark an approach based on explicitly-correlated coupled-cluster theory and vibrational perturbation theory (VPT2). Methyldioxy and Methyl Hydroperoxide are important and well-characterized species in combustion processes and begin the family of (ethyl-, propyl-based, etc) similar compounds (much less is known about the larger members). Accurate anharmonic frequencies are essential to accurately describe even the 0 K enthalpies of formation, but are especially important for finite temperature studies. Here we benchmark the spectroscopic and thermochemical accuracy of the approach, comparing with available data for the smallest systems, and comment on the outlook for larger systems that are less well-known and characterized. ^{1}B. Ruscic, Active Thermochemical Tables (ATcT) values based on ver. 1.118 of the Thermochemical Network (2015); available at ATcT.anl.gov ^{2}A. Tajti, P. G. Szalay, A. G. Császár, M. Kállay, J. Gauss, E. F. Valeev, B. A. Flowers, J. Vázquez, and J. F. Stanton. JCP 121, (2004): 11599.

  14. A high-accuracy surgical augmented reality system using enhanced integral videography image overlay.

    Science.gov (United States)

    Zhang, Xinran; Chen, Guowen; Liao, Hongen

    2015-01-01

    Image guided surgery has been used in clinic to improve the surgery safety and accuracy. Augmented reality (AR) technique, which can provide intuitive image guidance, has been greatly evolved these years. As one promising approach of surgical AR systems, integral videography (IV) autostereoscopic image overlay has achieved accurate fusion of full parallax guidance into surgical scene. This paper describes an image enhanced high-accuracy IV overlay system. A flexible optical image enhancement system (IES) is designed to increase the resolution and quality of IV image. Furthermore, we introduce a novel IV rendering algorithm to promote the spatial accuracy with the consideration of distortion introduced by micro lens array. Preliminary experiments validated that the image accuracy and resolution are improved with the proposed methods. The resolution of the IV image could be promoted to 1 mm for a micro lens array with pitch of 2.32 mm and IES magnification value of 0.5. The relative deviation of accuracy in depth and lateral directions are -4.68 ± 0.83% and -9.01 ± 0.42%.

  15. High Accuracy Nonlinear Control and Estimation for Machine Tool Systems

    DEFF Research Database (Denmark)

    Papageorgiou, Dimitrios

    sophisticated machine tool systems that are adaptable to different workspace conditions, while at the same time being able to maintain very narrow workpiece tolerances. The main topic of this thesis is to suggest control methods that can maintain required manufacturing tolerances, despite moderate wear and tear......Component mass production has been the backbone of industry since the second industrial revolution, and machine tools are producing parts of widely varying size and design complexity. The ever-increasing level of automation in modern manufacturing processes necessitates the use of more....... The purpose is to ensure that full accuracy is maintained between service intervals and to advice when overhaul is needed. The thesis argues that quality of manufactured components is directly related to the positioning accuracy of the machine tool axes, and it shows which low level control architectures...

  16. New solution for the high accuracy alignment of accelerator components

    Directory of Open Access Journals (Sweden)

    D. Caiazza

    2017-08-01

    Full Text Available Several state-of-the-art metrology measurement methods have been investigated and combined for a fiducialization of accelerator components in the micrometric regime. The PACMAN project at CERN applied stretched-wire measurement methods to Compact Linear Collider quadrupole and cavity beam position monitor prototypes, to locate their magnetic, respectively, electromagnetic, axis using a dedicated test stand and to determine the position of the wire with respect to external alignment targets (fiducials testing different methods, such as coordinate measuring machine measurements and microtriangulation. Further studies have been performed using a nanopositioning system, verifying the absolute accuracy and repeatability of the fiducialization method within a few micrometers.

  17. Design of a high linearity and high gain accuracy analog baseband circuit for DAB receiver

    Science.gov (United States)

    Li, Ma; Zhigong, Wang; Jian, Xu; Yiqiang, Wu; Junliang, Wang; Mi, Tian; Jianping, Chen

    2015-02-01

    An analog baseband circuit of high linearity and high gain accuracy for a digital audio broadcasting receiver is implemented in a 0.18-μm RFCMOS process. The circuit comprises a 3rd-order active-RC complex filter (CF) and a programmable gain amplifier (PGA). An automatic tuning circuit is also designed to tune the CF's pass band. Instead of the class-A fully differential operational amplifier (FDOPA) adopted in the conventional CF and PGA design, a class-AB FDOPA is specially employed in this circuit to achieve a higher linearity and gain accuracy for its large current swing capability with lower static current consumption. In the PGA circuit, a novel DC offset cancellation technique based on the MOS resistor is introduced to reduce the settling time significantly. A reformative switching network is proposed, which can eliminate the switch resistor's influence on the gain accuracy of the PGA. The measurement result shows the gain range of the circuit is 10-50 dB with a 1-dB step size, and the gain accuracy is less than ±0.3 dB. The OIP3 is 23.3 dBm at the gain of 10 dB. Simulation results show that the settling time is reduced from 100 to 1 ms. The image band rejection is about 40 dB. It only draws 4.5 mA current from a 1.8 V supply voltage.

  18. Accuracy of High-Rate GPS for Seismology

    Science.gov (United States)

    Elosegui, P.; Davis, J. L.; Oberlander, D.; Baena, R.; Ekstrom, G.

    2006-01-01

    We built a device for translating a GPS antenna on a positioning table to simulate the ground motions caused by an earthquake. The earthquake simulator is accurate to better than 0.1 mm in position, and provides the "ground truth" displacements for assessing the technique of high-rate GPS. We found that the root-mean-square error of the 1-Hz GPS position estimates over the 15-min duration of the simulated seismic event was 2.5 mm, with approximately 96% of the observations in error by less than 5 mm, and is independent of GPS antenna motion. The error spectrum of the GPS estimates is approximately flicker noise, with a 50% decorrelation time for the position error of approx.1.6 s. We that, for the particular event simulated, the spectrum of dependent error in the GPS measurements. surface deformations exceeds the GPS error spectrum within a finite band. More studies are required to determine whether a generally optimal bandwidth exists for a target group of seismic events.

  19. Micro-vision-based displacement measurement with high accuracy

    Science.gov (United States)

    Lu, Qinghua; Zhang, Xianmin; Fan, Yanbin

    2011-12-01

    The micro-motion stages are widely used in micro/nano manufacturing technology. In this paper, an integrated approach for measuring micro-displacement of micro-motion stage that incorporates motion estimation algorithm into the computer microvision is proposed. At first, the basic principle of the computer microvision measurement is analyzed. Then, a robust multiscale motion estimation algorithm for micro-motion measurement is proposed. Finally, the microdisplacement of the micro-motion stage based on the piezoelectric ceramic actuators and the compliant mechanisms is measured using the integrated approach. The maximal bias of the proposed approach reached 13 nm. Experimental results show that the new integrated method can measure micro-displacement with nanometer accuracy.

  20. A smart high accuracy silicon piezoresistive pressure sensor temperature compensation system.

    Science.gov (United States)

    Zhou, Guanwu; Zhao, Yulong; Guo, Fangfang; Xu, Wenju

    2014-07-08

    Theoretical analysis in this paper indicates that the accuracy of a silicon piezoresistive pressure sensor is mainly affected by thermal drift, and varies nonlinearly with the temperature. Here, a smart temperature compensation system to reduce its effect on accuracy is proposed. Firstly, an effective conditioning circuit for signal processing and data acquisition is designed. The hardware to implement the system is fabricated. Then, a program is developed on LabVIEW which incorporates an extreme learning machine (ELM) as the calibration algorithm for the pressure drift. The implementation of the algorithm was ported to a micro-control unit (MCU) after calibration in the computer. Practical pressure measurement experiments are carried out to verify the system's performance. The temperature compensation is solved in the interval from -40 to 85 °C. The compensated sensor is aimed at providing pressure measurement in oil-gas pipelines. Compared with other algorithms, ELM acquires higher accuracy and is more suitable for batch compensation because of its higher generalization and faster learning speed. The accuracy, linearity, zero temperature coefficient and sensitivity temperature coefficient of the tested sensor are 2.57% FS, 2.49% FS, 8.1 × 10(-5)/°C and 29.5 × 10(-5)/°C before compensation, and are improved to 0.13%FS, 0.15%FS, 1.17 × 10(-5)/°C and 2.1 × 10(-5)/°C respectively, after compensation. The experimental results demonstrate that the proposed system is valid for the temperature compensation and high accuracy requirement of the sensor.

  1. A Smart High Accuracy Silicon Piezoresistive Pressure Sensor Temperature Compensation System

    Directory of Open Access Journals (Sweden)

    Guanwu Zhou

    2014-07-01

    Full Text Available Theoretical analysis in this paper indicates that the accuracy of a silicon piezoresistive pressure sensor is mainly affected by thermal drift, and varies nonlinearly with the temperature. Here, a smart temperature compensation system to reduce its effect on accuracy is proposed. Firstly, an effective conditioning circuit for signal processing and data acquisition is designed. The hardware to implement the system is fabricated. Then, a program is developed on LabVIEW which incorporates an extreme learning machine (ELM as the calibration algorithm for the pressure drift. The implementation of the algorithm was ported to a micro-control unit (MCU after calibration in the computer. Practical pressure measurement experiments are carried out to verify the system’s performance. The temperature compensation is solved in the interval from −40 to 85 °C. The compensated sensor is aimed at providing pressure measurement in oil-gas pipelines. Compared with other algorithms, ELM acquires higher accuracy and is more suitable for batch compensation because of its higher generalization and faster learning speed. The accuracy, linearity, zero temperature coefficient and sensitivity temperature coefficient of the tested sensor are 2.57% FS, 2.49% FS, 8.1 × 10−5/°C and 29.5 × 10−5/°C before compensation, and are improved to 0.13%FS, 0.15%FS, 1.17 × 10−5/°C and 2.1 × 10−5/°C respectively, after compensation. The experimental results demonstrate that the proposed system is valid for the temperature compensation and high accuracy requirement of the sensor.

  2. High-accuracy oxygen polarograph for photosynthetic systems

    Science.gov (United States)

    Meunier, P. C.; Popovic, R.

    1988-03-01

    A new system is presented here, whose design is based on the electrochemical phenomena occurring on the platinum electrode that we examined before [P. Meunier and R. Popovic (unpublished)]. The architecture of the system is articulated around an IBM-PC computer which controls the polarization of the electrodes, the triggering of the flash lamp, and the acquisition of data. The potentiostat circuit and new electrode design improve the response of the electrode to a rise time of 4 ms and a decay time constant of 21 ms, without the signal being distorted by filters and without using the first derivative of the signal. This polarograph shows a 50-dB signal-to-noise ratio (0.3% error) during experiments with the motile algae Dunaliella tertiolecta. The determination of amplitudes of oxygen production is performed with third-order cubic spline interpolations, after subtraction of the current base line. The resulting accuracy and reproducibility will enable researchers to attain a higher degree of refinement in the quantification of properties of the oxygen evolving complex.

  3. Transcutaneous PTCCO2 measurement in combination with arterial blood gas analysis provides superior accuracy and reliability in ICU patients.

    Science.gov (United States)

    Spelten, Oliver; Fiedler, Fritz; Schier, Robert; Wetsch, Wolfgang A; Hinkelbein, Jochen

    2017-02-01

    Hyper or hypoventilation may have serious clinical consequences in critically ill patients and should be generally avoided, especially in neurosurgical patients. Therefore, monitoring of carbon dioxide partial pressure by intermittent arterial blood gas analysis (PaCO2) has become standard in intensive care units (ICUs). However, several additional methods are available to determine PCO2 including end-tidal (PETCO2) and transcutaneous (PTCCO2) measurements. The aim of this study was to compare the accuracy and reliability of different methods to determine PCO2 in mechanically ventilated patients on ICU. After approval of the local ethics committee PCO2 was determined in n = 32 ICU consecutive patients requiring mechanical ventilation: (1) arterial PaCO2 blood gas analysis with Radiometer ABL 625 (ABL; gold standard), (2) arterial PaCO2 analysis with Immediate Response Mobile Analyzer (IRMA), (3) end-tidal PETCO2 by a Propaq 106 EL monitor and (4) transcutaneous PTCCO2 determination by a Tina TCM4. Bland-Altman method was used for statistical analysis; p analysis revealed good correlation between PaCO2 by IRMA and ABL (R2 = 0.766; p analysis revealed a bias and precision of 2.0 ± 3.7 mmHg for the IRMA, 2.2 ± 5.7 mmHg for transcutaneous, and -5.5 ± 5.6 mmHg for end-tidal measurement. Arterial CO2 partial pressure by IRMA (PaCO2) and PTCCO2 provided greater accuracy compared to the reference measurement (ABL) than the end-tidal CO2 measurements in critically ill in mechanically ventilated patients patients.

  4. Emergency positioning system accuracy with infrared LEDs in high-security facilities

    Science.gov (United States)

    Knoch, Sierra N.; Nelson, Charles; Walker, Owens

    2017-05-01

    Instantaneous personnel location presents a challenge in Department of Defense applications where high levels of security restrict real-time tracking of crew members. During emergency situations, command and control requires immediate accountability of all personnel. Current radio frequency (RF) based indoor positioning systems can be unsuitable due to RF leakage and electromagnetic interference with sensitively calibrated machinery on variable platforms like ships, submarines and high-security facilities. Infrared light provide a possible solution to this problem. This paper proposes and evaluates an indoor line-of-sight positioning system that is comprised of IR and high-sensitivity CMOS camera receivers. In this system the movement of the LEDs is captured by the camera, uploaded and analyzed; the highest point of power is located and plotted to create a blueprint of crewmember location. Results provided evaluate accuracy as a function of both wavelength and environmental conditions. Research will further evaluate the accuracy of the LED transmitter and CMOS camera receiver system. Transmissions in both the 780 and 850nm IR are analyzed.

  5. Sensitivity and accuracy of high-throughput metabarcoding methods for early detection of invasive fish species

    Science.gov (United States)

    Hatzenbuhler, Chelsea; Kelly, John R.; Martinson, John; Okum, Sara; Pilgrim, Erik

    2017-04-01

    High-throughput DNA metabarcoding has gained recognition as a potentially powerful tool for biomonitoring, including early detection of aquatic invasive species (AIS). DNA based techniques are advancing, but our understanding of the limits to detection for metabarcoding complex samples is inadequate. For detecting AIS at an early stage of invasion when the species is rare, accuracy at low detection limits is key. To evaluate the utility of metabarcoding in future fish community monitoring programs, we conducted several experiments to determine the sensitivity and accuracy of routine metabarcoding methods. Experimental mixes used larval fish tissue from multiple “common” species spiked with varying proportions of tissue from an additional “rare” species. Pyrosequencing of genetic marker, COI (cytochrome c oxidase subunit I) and subsequent sequence data analysis provided experimental evidence of low-level detection of the target “rare” species at biomass percentages as low as 0.02% of total sample biomass. Limits to detection varied interspecifically and were susceptible to amplification bias. Moreover, results showed some data processing methods can skew sequence-based biodiversity measurements from corresponding relative biomass abundances and increase false absences. We suggest caution in interpreting presence/absence and relative abundance in larval fish assemblages until metabarcoding methods are optimized for accuracy and precision.

  6. High-accuracy Subdaily ERPs from the IGS

    Science.gov (United States)

    Ray, J. R.; Griffiths, J.

    2012-04-01

    Since November 2000 the International GNSS Service (IGS) has published Ultra-rapid (IGU) products for near real-time (RT) and true real-time applications. They include satellite orbits and clocks, as well as Earth rotation parameters (ERPs) for a sliding 48-hr period. The first day of each update is based on the most recent GPS and GLONASS observational data from the IGS hourly tracking network. At the time of release, these observed products have an initial latency of 3 hr. The second day of each update consists of predictions. So the predictions between about 3 and 9 hr into the second half are relevant for true RT uses. Originally updated twice daily, the IGU products since April 2004 have been issued every 6 hr, at 3, 9, 15, and 21 UTC. Up to seven Analysis Centers (ACs) contribute to the IGU combinations. Two sets of ERPs are published with each IGU update, observed values at the middle epoch of the first half and predicted values at the middle epoch of the second half. The latency of the near RT ERPs is 15 hr while the predicted ERPs, based on projections of each AC's most recent determinations, are issued 9 hr ahead of their reference epoch. While IGU ERPs are issued every 6 hr, each set represents an integrated estimate over the surrounding 24 hr. So successive values are temporally correlated with about 75% of the data being common; this fact should be taken into account in user assimilations. To evaluate the accuracy of these near RT and predicted ERPs, they have been compared to the IGS Final ERPs, available about 11 to 17 d after data collection. The IGU products improved dramatically in the earlier years but since about 2008.0 the performance has been stable and excellent. During the last three years, RMS differences for the observed IGU ERPs have been about 0.036 mas and 0.0101 ms for each polar motion component and LOD respectively. (The internal precision of the reference IGS ERPs over the same period is about 0.016 mas for polar motion and 0

  7. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  8. A High Accuracy Method for Semi-supervised Information Extraction

    Energy Technology Data Exchange (ETDEWEB)

    Tratz, Stephen C.; Sanfilippo, Antonio P.

    2007-04-22

    Customization to specific domains of dis-course and/or user requirements is one of the greatest challenges for today’s Information Extraction (IE) systems. While demonstrably effective, both rule-based and supervised machine learning approaches to IE customization pose too high a burden on the user. Semi-supervised learning approaches may in principle offer a more resource effective solution but are still insufficiently accurate to grant realistic application. We demonstrate that this limitation can be overcome by integrating fully-supervised learning techniques within a semi-supervised IE approach, without increasing resource requirements.

  9. Gated viewing and high-accuracy three-dimensional laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a fast and high-accuracy three-dimensional (3-D) imaging laser radar that can achieve better than 1 mm range accuracy for half a million pixels in less than 1 s. Our technique is based on range-gating segmentation. We combine the advantages of gated viewing with our new fast...

  10. High-Reproducibility and High-Accuracy Method for Automated Topic Classification

    Directory of Open Access Journals (Sweden)

    Andrea Lancichinetti

    2015-01-01

    Full Text Available Much of human knowledge sits in large databases of unstructured text. Leveraging this knowledge requires algorithms that extract and record metadata on unstructured text documents. Assigning topics to documents will enable intelligent searching, statistical characterization, and meaningful classification. Latent Dirichlet allocation (LDA is the state of the art in topic modeling. Here, we perform a systematic theoretical and numerical analysis that demonstrates that current optimization techniques for LDA often yield results that are not accurate in inferring the most suitable model parameters. Adapting approaches from community detection in networks, we propose a new algorithm that displays high reproducibility and high accuracy and also has high computational efficiency. We apply it to a large set of documents in the English Wikipedia and reveal its hierarchical structure.

  11. Achieving High Accuracy in Calculations of NMR Parameters

    DEFF Research Database (Denmark)

    Faber, Rasmus

    information about the relative positions of nuclei are also obtained. Due to the widespread use of NMR spectroscopy, there is a keen interest in theoretical predictions of the relevant parameters, the nuclear shielding constants and indirect nuclear spin-spin coupling constants (SSCC). Though highly advanced...... calculations are today typically based on coupled cluster (CC) theory. The CCSD(T) method is very popular and is known to give accurate results for a wide range of molecular properties, including nuclear shielding constants, but not SSCCs. An alternative to CCSD(T) for calculating SSCCs could be the CC3 method...... that CC3 captures important correlation effects ignored by the previous standard method, CCSD. Indeed, CC3 is shown to accurately reproduce gas-phase experimental results for the SSCCs of acetylene. In any molecular property calculation the one-electron basis set must be chosen with care as the basis set...

  12. The accuracy of QCD perturbation theory at high energies

    CERN Document Server

    Dalla Brida, Mattia; Korzec, Tomasz; Ramos, Alberto; Sint, Stefan; Sommer, Rainer

    2016-01-01

    We discuss the determination of the strong coupling $\\alpha_\\mathrm{\\overline{MS}}^{}(m_\\mathrm{Z})$ or equivalently the QCD $\\Lambda$-parameter. Its determination requires the use of perturbation theory in $\\alpha_s(\\mu)$ in some scheme, $s$, and at some energy scale $\\mu$. The higher the scale $\\mu$ the more accurate perturbation theory becomes, owing to asymptotic freedom. As one step in our computation of the $\\Lambda$-parameter in three-flavor QCD, we perform lattice computations in a scheme which allows us to non-perturbatively reach very high energies, corresponding to $\\alpha_s = 0.1$ and below. We find that perturbation theory is very accurate there, yielding a three percent error in the $\\Lambda$-parameter, while data around $\\alpha_s \\approx 0.2$ is clearly insufficient to quote such a precision. It is important to realize that these findings are expected to be generic, as our scheme has advantageous properties regarding the applicability of perturbation theory.

  13. Magnetoresistive Current Sensors for High Accuracy, High Bandwidth Current Measurement in Spacecraft Power Electronics

    Science.gov (United States)

    Slatter, Rolf; Goffin, Benoit

    2014-08-01

    The usage of magnetoresistive (MR) current sensors is increasing steadily in the field of power electronics. Current sensors must not only be accurate and dynamic, but must also be compact and robust. The MR effect is the basis for current sensors with a unique combination of precision and bandwidth in a compact package. A space-qualifiable magnetoresistive current sensor with high accuracy and high bandwidth is being jointly developed by the sensor manufacturer Sensitec and the spacecraft power electronics supplier Thales Alenia Space (T AS) Belgium. Test results for breadboards incorporating commercial-off-the-shelf (COTS) sensors are presented as well as an application example in the electronic control and power unit for the thrust vector actuators of the Ariane5-ME launcher.

  14. Accuracy assessment of NOAA gridded daily reference evapotranspiration for the Texas High Plains

    Science.gov (United States)

    Moorhead, Jerry; Gowda, Prasanna H.; Hobbins, Michael; Senay, Gabriel; Paul, George; Marek, Thomas; Porter, Dana

    2015-01-01

    The National Oceanic and Atmospheric Administration (NOAA) provides daily reference evapotranspiration (ETref) maps for the contiguous United States using climatic data from North American Land Data Assimilation System (NLDAS). This data provides large-scale spatial representation of ETref, which is essential for regional scale water resources management. Data used in the development of NOAA daily ETref maps are derived from observations over surfaces that are different from short (grass — ETos) or tall (alfalfa — ETrs) reference crops, often in nonagricultural settings, which carries an unknown discrepancy between assumed and actual conditions. In this study, NOAA daily ETos and ETrs maps were evaluated for accuracy, using observed data from the Texas High Plains Evapotranspiration (TXHPET) network. Daily ETos, ETrs and the climatic data (air temperature, wind speed, and solar radiation) used for calculating ETref were extracted from the NOAA maps for TXHPET locations and compared against ground measurements on reference grass surfaces. NOAA ETrefmaps generally overestimated the TXHPET observations (1.4 and 2.2 mm/day ETos and ETrs, respectively), which may be attributed to errors in the NLDAS modeled air temperature and wind speed, to which reference ETref is most sensitive. Therefore, a bias correction to NLDAS modeled air temperature and wind speed data, or adjustment to the resulting NOAA ETref, may be needed to improve the accuracy of NOAA ETref maps.

  15. SpaceNav - A high accuracy navigation system for space applications

    Science.gov (United States)

    Evers, H.-H.

    The technology of the SpaceNav-system is based on research performed by the Institute of Flight Guidance and Control at the Technical University of Braunschweig, Germany. In 1989 this institute gave the worlds first public demonstration of a fully automatic landing of an aircraft, using inertial and satellite informations exclusively. The SpaceNav device components are: Acceleration-/Gyro Sensor Package; Global Positioning System (GPS) Receiver/optional more than one; Time Reference Unit; CPU; Telemetry (optional); and Differential GPS (DGPS) Receiver (optional). The coupling of GPS receivers with inertial sensors provides an extremely accurate navigation data set in real time applications even in phases with high dynamic conditions. The update rate of this navigation information is up to 100 Hz with the same accuracy in 3D-position, velocity, acceleration, attitude and time. SpaceNav is an integrated navigation system, which operates according to the principle of combining the longterm stability and accuracy of GPS, and the high level of dynamic precision of conventional inertial navigation system (INS) strapdown systems. The system's design allows other aiding sensors e.g. GLONASS satellite navigation system, distance measuring equipment (DME), altimeter (radar and/or barometric), flux valve etc. to be connected, in order to increase the redundancy of the system. The advantage of such an upgraded system is the availability of more sensor information than necessary for a navigation solution. The resulting redundancy in range measurement allows real-time detection and identification of sensor signals that are incompatible with the other information. As a result you get Receiver Autonomous Integrity Monitoring (RAIM) as described in 'A Multi-Sensor Approach to Assuring GPS Integrity', presented by Alison Brown in the March/April 1990 issue of 'GPS World'. In this paper the author presents information about the principles of the Satellite Navigation System GPS, and

  16. About accuracy of the discrimination parameter estimation for the dual high-energy method

    OpenAIRE

    Osipov, Sergey Pavlovich; Chakhlov, Sergey Vladimirovich; Осипов, Олег Сергеевич; Stein, Aleksandr Mikhailovich; Strugovtsev, D. V.

    2015-01-01

    A set of the mathematical formulas to estimate the accuracy of discrimination parameters for two implementations of the dual high energy method - by the effective atomic number and by the level lines is given. The hardware parameters which influenced on the accuracy of the discrimination parameters are stated. The recommendations to form the structure of the high energy X-ray radiation impulses are formulated. To prove the applicability of the proposed procedure there were calculated the stat...

  17. Polarization-independent optical circulator for high accuracy Faraday depolarization lidar.

    Science.gov (United States)

    Shiina, Tatsuo; Noguchi, Kazuo; Fukuchi, Tetsuo

    2012-03-01

    A high precision, polarization-independent optical circulator was developed for high accuracy Faraday depolarization lidar. Glan laser prisms and other novel optics were utilized in the circulator optics, resulting in a high extinction ratio of polarization of >30 dB. High accuracy is needed to detect a small rotation angle in the polarization plane of the propagating beam. It is generated by the Faraday effect due to the lightning discharge. The developed circulator delivered high performance of insertion loss and isolation as laser transmitter and echo receiver in the inline lidar optics. © 2012 Optical Society of America

  18. Innovative Technique for High-Accuracy Remote Monitoring of Surface Water

    Science.gov (United States)

    Gisler, A.; Barton-Grimley, R. A.; Thayer, J. P.; Crowley, G.

    2016-12-01

    Lidar (light detection and ranging) provides absolute depth and topographic mapping capability compared to other remote sensing methods, which is useful for mapping rapidly changing environments such as riverine systems and agricultural waterways. Effectiveness of current lidar bathymetric systems is limited by the difficulty in unambiguously identifying backscattered lidar signals from the water surface versus the bottom, limiting their depth resolution to 0.3-0.5 m. Additionally these are large, bulky systems that are constrained to expensive aircraft-mounted platforms and use waveform-processing techniques requiring substantial computation time. These restrictions are prohibitive for many potential users. A novel lidar device has been developed that allows for non-contact measurements of water depth down to 1 cm with an accuracy and precision of laser pulse repetition rate allows for very fine horizontal resolution while the photon-counting technique permits real-time depth measurement and object detection. The enhanced measurement capability, portability, scalability, and relatively low-cost creates the opportunity to perform frequent high-accuracy monitoring and measuring of aquatic environments which is crucial for monitoring water resources on fast timescales. Results from recent campaigns measuring water depth in flowing creeks and murky ponds will be presented which demonstrate that the method is not limited by rough water surfaces and can map underwater topology through moderately turbid water.

  19. PACMAN Project: A New Solution for the High-accuracy Alignment of Accelerator Components

    CERN Document Server

    Mainaud Durand, Helene; Buzio, Marco; Caiazza, Domenico; Catalán Lasheras, Nuria; Cherif, Ahmed; Doytchinov, Iordan; Fuchs, Jean-Frederic; Gaddi, Andrea; Galindo Munoz, Natalia; Gayde, Jean-Christophe; Kamugasa, Solomon; Modena, Michele; Novotny, Peter; Russenschuck, Stephan; Sanz, Claude; Severino, Giordana; Tshilumba, David; Vlachakis, Vasileios; Wendt, Manfred; Zorzetti, Silvia

    2016-01-01

    The beam alignment requirements for the next generation of lepton colliders have become increasingly challenging. As an example, the alignment requirements for the three major collider components of the CLIC linear collider are as follows. Before the first beam circulates, the Beam Position Monitors (BPM), Accelerating Structures (AS)and quadrupoles will have to be aligned up to 10 μm w.r.t. a straight line over 200 m long segments, along the 20 km of linacs. PACMAN is a study on Particle Accelerator Components' Metrology and Alignment to the Nanometre scale. It is an Innovative Doctoral Program, funded by the EU and hosted by CERN, providing high quality training to 10 Early Stage Researchers working towards a PhD thesis. The technical aim of the project is to improve the alignment accuracy of the CLIC components by developing new methods and tools addressing several steps of alignment simultaneously, to gain time and accuracy. The tools and methods developed will be validated on a test bench. This paper pr...

  20. A high-accuracy measurement method of glucose concentration in interstitial fluid based on microdialysis

    Science.gov (United States)

    Li, Dachao; Xu, Qingmei; Liu, Yu; Wang, Ridong; Xu, Kexin; Yu, Haixia

    2017-11-01

    A high-accuracy microdialysis method that can provide the reference values of glucose concentration in interstitial fluid for the accurate evaluation of non-invasive and minimally invasive continuous glucose monitoring is reported in this study. The parameters of the microdialysis process were firstly optimized by testing and analyzing three main factors that impact microdialysis recovery, including the perfusion rate, temperature, and glucose concentration in the area surrounding the microdialysis probe. The precision of the optimized microdialysis method was then determined in a simulation system that was designed and established in this study to simulate variations in continuous glucose concentration in the human body. Finally, the microdialysis method was tested for in vivo interstitial glucose concentration measurement.

  1. Ultrasound indoor positioning system based on a low-power wireless sensor network providing sub-centimeter accuracy.

    Science.gov (United States)

    Medina, Carlos; Segura, José Carlos; De la Torre, Ángel

    2013-03-13

    This paper describes the TELIAMADE system, a new indoor positioning system based on time-of-flight (TOF) of ultrasonic signal to estimate the distance between a receiver node and a transmitter node. TELIAMADE system consists of a set of wireless nodes equipped with a radio module for communication and a module for the transmission and reception of ultrasound. The access to the ultrasonic channel is managed by applying a synchronization algorithm based on a time-division multiplexing (TDMA) scheme. The ultrasonic signal is transmitted using a carrier frequency of 40 kHz and the TOF measurement is estimated by applying a quadrature detector to the signal obtained at the A/D converter output. Low sampling frequencies of 17.78 kHz or even 12.31 kHz are possible using quadrature sampling in order to optimize memory requirements and to reduce the computational cost in signal processing. The distance is calculated from the TOF taking into account the speed of sound. An excellent accuracy in the estimation of the TOF is achieved using parabolic interpolation to detect of maximum of the signal envelope at the matched filter output. The signal phase information is also used for enhancing the TOF measurement accuracy. Experimental results show a root mean square error (rmse) less than 2 mm and a standard deviation less than 0.3 mm for pseudorange measurements in the range of distances between 2 and 6 m. The system location accuracy is also evaluated by applying multilateration. A sub-centimeter location accuracy is achieved with an average rmse of 9.6 mm.

  2. Ultrasound Indoor Positioning System Based on a Low-Power Wireless Sensor Network Providing Sub-Centimeter Accuracy

    Directory of Open Access Journals (Sweden)

    Ángel De la Torre

    2013-03-01

    Full Text Available This paper describes the TELIAMADE system, a new indoor positioning system based on time-of-flight (TOF of ultrasonic signal to estimate the distance between a receiver node and a transmitter node. TELIAMADE system consists of a set of wireless nodes equipped with a radio module for communication and a module for the transmission and reception of ultrasound. The access to the ultrasonic channel is managed by applying a synchronization algorithm based on a time-division multiplexing (TDMA scheme. The ultrasonic signal is transmitted using a carrier frequency of 40 kHz and the TOF measurement is estimated by applying a quadrature detector to the signal obtained at the A/D converter output. Low sampling frequencies of 17.78 kHz or even 12.31 kHz are possible using quadrature sampling in order to optimize memory requirements and to reduce the computational cost in signal processing. The distance is calculated from the TOF taking into account the speed of sound. An excellent accuracy in the estimation of the TOF is achieved using parabolic interpolation to detect of maximum of the signal envelope at the matched filter output. The signal phase information is also used for enhancing the TOF measurement accuracy. Experimental results show a root mean square error (rmse less than 2 mm and a standard deviation less than 0.3 mm for pseudorange measurements in the range of distances between 2 and 6 m. The system location accuracy is also evaluated by applying multilateration. A sub-centimeter location accuracy is achieved with an average rmse of 9.6 mm.

  3. High Accuracy Attitude Control System Design for Satellite with Flexible Appendages

    OpenAIRE

    Wenya Zhou; Haixu Wang; Zhengwei Ruan; Zhigang Wu; Enmei Wang

    2014-01-01

    In order to realize the high accuracy attitude control of satellite with flexible appendages, attitude control system consisting of the controller and structural filter was designed. When the low order vibration frequency of flexible appendages is approximating the bandwidth of attitude control system, the vibration signal will enter the control system through measurement device to bring impact on the accuracy or even the stability. In order to reduce the impact of vibration of appendages on ...

  4. Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery

    Directory of Open Access Journals (Sweden)

    Loutfi-Krauss Britta

    2017-09-01

    Full Text Available For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany, which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA with 4.0mm resolution and to the Nonius (QUART, Germany, a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm. The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for

  5. Prioritizing spatial accuracy in high-resolution fMRI data using multivariate feature weight mapping

    Directory of Open Access Journals (Sweden)

    Johannes eStelzer

    2014-04-01

    Full Text Available Although ultra-high-field fMRI at field strengths of 7T or above provides substantial gains in BOLD contrast-to-noise ratio, when very high-resolution fMRI is required such gains are inevitably reduced. The improvement in sensitivity provided by multivariate analysis techniques, as compared with univariate methods, then becomes especially welcome. Information mapping approaches are commonly used, such as the searchlight technique, which take into account the spatially distributed patterns of activation in order to predict stimulus conditions. However, the popular searchlight decoding technique, in particular, has been found to be prone to spatial inaccuracies. For instance, the spatial extent of informative areas is generally exaggerated, and their spatial configuration is distorted. We propose the combination of a nonparametric and permutation-based statistical framework with linear classifiers. We term this new combined method Feature Weight Mapping (FWM. The main goal of the proposed method is to map the specific contribution of each voxel to the classification decision while including a correction for the multiple comparisons problem. Next, we compare this new method to the searchlight approach using a simulation and ultra-high-field 7T experimental data. We found that the searchlight method led to spatial inaccuracies that are especially noticeable in high-resolution fMRI data. In contrast, FWM was more spatially precise, revealing both informative anatomical structures as well as the direction by which voxels contribute to the classification. By maximizing the spatial accuracy of ultra-high-field fMRI results, global multivariate methods provide a substantial improvement for characterizing structure-function relationships.

  6. High-accuracy drilling with an image guided light weight robot: autonomous versus intuitive feed control.

    Science.gov (United States)

    Tauscher, Sebastian; Fuchs, Alexander; Baier, Fabian; Kahrs, Lüder A; Ortmaier, Tobias

    2017-07-13

    Assistance of robotic systems in the operating room promises higher accuracy and, hence, demanding surgical interventions become realisable (e.g. the direct cochlear access). Additionally, an intuitive user interface is crucial for the use of robots in surgery. Torque sensors in the joints can be employed for intuitive interaction concepts. Regarding the accuracy, they lead to a lower structural stiffness and, thus, to an additional error source. The aim of this contribution is to examine, if an accuracy needed for demanding interventions can be achieved by such a system or not. Feasible accuracy results of the robot-assisted process depend on each work-flow step. This work focuses on the determination of the tool coordinate frame. A method for drill axis definition is implemented and analysed. Furthermore, a concept of admittance feed control is developed. This allows the user to control feeding along the planned path by applying a force to the robots structure. The accuracy is researched by drilling experiments with a PMMA phantom and artificial bone blocks. The described drill axis estimation process results in a high angular repeatability ([Formula: see text]). In the first set of drilling results, an accuracy of [Formula: see text] at entrance and [Formula: see text] at target point excluding imaging was achieved. With admittance feed control an accuracy of [Formula: see text] at target point was realised. In a third set twelve holes were drilled in artificial temporal bone phantoms including imaging. In this set-up an error of [Formula: see text] and [Formula: see text] was achieved. The results of conducted experiments show that accuracy requirements for demanding procedures such as the direct cochlear access can be fulfilled with compliant systems. Furthermore, it was shown that with the presented admittance feed control an accuracy of less then [Formula: see text] is achievable.

  7. High-accuracy Brillouin frequency shift measurement system based on stimulated Brillouin scattering phase shift

    Science.gov (United States)

    Li, Yongqian; An, Qi; Li, Xiaojuan; Zhang, Lixin

    2017-05-01

    A high-accuracy Brillouin frequency shift (BFS) measurement system for vector Brillouin optical time-domain analysis-based temperature sensor is proposed, in which double sideband modulation is used and the stimulated Brillouin scattering (SBS) gain and loss processes work together to generate a superimposed SBS phase-shift spectrum. The measurement principle is analyzed by mathematical modeling and the proof-of-concept experiment is performed by using a 100-m long standard single-mode fiber. The theoretical and experimental results reveal that the temperature sensitivity of BFS obtained from the measured SBS phase-shift spectrum is 1.059 MHz/°C, and the measurement error of temperature is only half that in traditional single sideband-based system, which indicates that the proposed technique can realize high-accuracy temperature measurement and have huge potential in the field of long-distance and high-accuracy sensing.

  8. Very high-accuracy calibration of radiation pattern and gain of a near-field probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Nielsen, Jeppe Majlund; Breinbjerg, Olav

    2014-01-01

    In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission of the Europ......In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission...

  9. Providing Internet Access to High-Resolution Mars Images

    Science.gov (United States)

    Plesea, Lucian

    2008-01-01

    The OnMars server is a computer program that provides Internet access to high-resolution Mars images, maps, and elevation data, all suitable for use in geographical information system (GIS) software for generating images, maps, and computational models of Mars. The OnMars server is an implementation of the Open Geospatial Consortium (OGC) Web Map Service (WMS) server. Unlike other Mars Internet map servers that provide Martian data using an Earth coordinate system, the OnMars WMS server supports encoding of data in Mars-specific coordinate systems. The OnMars server offers access to most of the available high-resolution Martian image and elevation data, including an 8-meter-per-pixel uncontrolled mosaic of most of the Mars Global Surveyor (MGS) Mars Observer Camera Narrow Angle (MOCNA) image collection, which is not available elsewhere. This server can generate image and map files in the tagged image file format (TIFF), Joint Photographic Experts Group (JPEG), 8- or 16-bit Portable Network Graphics (PNG), or Keyhole Markup Language (KML) format. Image control is provided by use of the OGC Style Layer Descriptor (SLD) protocol. The OnMars server also implements tiled WMS protocol and super-overlay KML for high-performance client application programs.

  10. Providing Internet Access to High-Resolution Lunar Images

    Science.gov (United States)

    Plesea, Lucian

    2008-01-01

    The OnMoon server is a computer program that provides Internet access to high-resolution Lunar images, maps, and elevation data, all suitable for use in geographical information system (GIS) software for generating images, maps, and computational models of the Moon. The OnMoon server implements the Open Geospatial Consortium (OGC) Web Map Service (WMS) server protocol and supports Moon-specific extensions. Unlike other Internet map servers that provide Lunar data using an Earth coordinate system, the OnMoon server supports encoding of data in Moon-specific coordinate systems. The OnMoon server offers access to most of the available high-resolution Lunar image and elevation data. This server can generate image and map files in the tagged image file format (TIFF) or the Joint Photographic Experts Group (JPEG), 8- or 16-bit Portable Network Graphics (PNG), or Keyhole Markup Language (KML) format. Image control is provided by use of the OGC Style Layer Descriptor (SLD) protocol. Full-precision spectral arithmetic processing is also available, by use of a custom SLD extension. This server can dynamically add shaded relief based on the Lunar elevation to any image layer. This server also implements tiled WMS protocol and super-overlay KML for high-performance client application programs.

  11. High-accuracy extrapolated ab initio thermochemistry. II. Minor improvements to the protocol and a vital simplification.

    Science.gov (United States)

    Bomble, Yannick J; Vázquez, Juana; Kállay, Mihály; Michauk, Christine; Szalay, Péter G; Császár, Attila G; Gauss, Jürgen; Stanton, John F

    2006-08-14

    The recently developed high-accuracy extrapolated ab initio thermochemistry method for theoretical thermochemistry, which is intimately related to other high-precision protocols such as the Weizmann-3 and focal-point approaches, is revisited. Some minor improvements in theoretical rigor are introduced which do not lead to any significant additional computational overhead, but are shown to have a negligible overall effect on the accuracy. In addition, the method is extended to completely treat electron correlation effects up to pentuple excitations. The use of an approximate treatment of quadruple and pentuple excitations is suggested; the former as a pragmatic approximation for standard cases and the latter when extremely high accuracy is required. For a test suite of molecules that have rather precisely known enthalpies of formation {as taken from the active thermochemical tables of Ruscic and co-workers [Lecture Notes in Computer Science, edited by M. Parashar (Springer, Berlin, 2002), Vol. 2536, pp. 25-38; J. Phys. Chem. A 108, 9979 (2004)]}, the largest deviations between theory and experiment are 0.52, -0.70, and 0.51 kJ mol(-1) for the latter three methods, respectively. Some perspective is provided on this level of accuracy, and sources of remaining systematic deficiencies in the approaches are discussed.

  12. Experimental studies of high-accuracy RFID localization with channel impairments

    Science.gov (United States)

    Pauls, Eric; Zhang, Yimin D.

    2015-05-01

    Radio frequency identification (RFID) systems present an incredibly cost-effective and easy-to-implement solution to close-range localization. One of the important applications of a passive RFID system is to determine the reader position through multilateration based on the estimated distances between the reader and multiple distributed reference tags obtained from, e.g., the received signal strength indicator (RSSI) readings. In practice, the achievable accuracy of passive RFID reader localization suffers from many factors, such as the distorted RSSI reading due to channel impairments in terms of the susceptibility to reader antenna patterns and multipath propagation. Previous studies have shown that the accuracy of passive RFID localization can be significantly improved by properly modeling and compensating for such channel impairments. The objective of this paper is to report experimental study results that validate the effectiveness of such approaches for high-accuracy RFID localization. We also examine a number of practical issues arising in the underlying problem that limit the accuracy of reader-tag distance measurements and, therefore, the estimated reader localization. These issues include the variations in tag radiation characteristics for similar tags, effects of tag orientations, and reader RSS quantization and measurement errors. As such, this paper reveals valuable insights of the issues and solutions toward achieving high-accuracy passive RFID localization.

  13. Accuracy of protein-protein binding sites in high-throughput template-based modeling.

    Directory of Open Access Journals (Sweden)

    Petras J Kundrotas

    2010-04-01

    Full Text Available The accuracy of protein structures, particularly their binding sites, is essential for the success of modeling protein complexes. Computationally inexpensive methodology is required for genome-wide modeling of such structures. For systematic evaluation of potential accuracy in high-throughput modeling of binding sites, a statistical analysis of target-template sequence alignments was performed for a representative set of protein complexes. For most of the complexes, alignments containing all residues of the interface were found. The full interface alignments were obtained even in the case of poor alignments where a relatively small part of the target sequence (as low as 40% aligned to the template sequence, with a low overall alignment identity (<30%. Although such poor overall alignments might be considered inadequate for modeling of whole proteins, the alignment of the interfaces was strong enough for docking. In the set of homology models built on these alignments, one third of those ranked 1 by a simple sequence identity criteria had RMSD<5 A, the accuracy suitable for low-resolution template free docking. Such models corresponded to multi-domain target proteins, whereas for single-domain proteins the best models had 5 Aaccuracy suitable for less sensitive structure-alignment methods. Overall, approximately 50% of complexes with the interfaces modeled by high-throughput techniques had accuracy suitable for meaningful docking experiments. This percentage will grow with the increasing availability of co-crystallized protein-protein complexes.

  14. Accuracy of hiatal hernia detection with esophageal high-resolution manometry

    NARCIS (Netherlands)

    Weijenborg, P. W.; van Hoeij, F. B.; Smout, A. J. P. M.; Bredenoord, A. J.

    2015-01-01

    The diagnosis of a sliding hiatal hernia is classically made with endoscopy or barium esophagogram. Spatial separation of the lower esophageal sphincter (LES) and diaphragm, the hallmark of hiatal hernia, can also be observed on high-resolution manometry (HRM), but the diagnostic accuracy of this

  15. Method for providing a low density high strength polyurethane foam

    Science.gov (United States)

    Whinnery, Jr., Leroy L.; Goods, Steven H.; Skala, Dawn M.; Henderson, Craig C.; Keifer, Patrick N.

    2013-06-18

    Disclosed is a method for making a polyurethane closed-cell foam material exhibiting a bulk density below 4 lbs/ft.sup.3 and high strength. The present embodiment uses the reaction product of a modified MDI and a sucrose/glycerine based polyether polyol resin wherein a small measured quantity of the polyol resin is "pre-reacted" with a larger quantity of the isocyanate in a defined ratio such that when the necessary remaining quantity of the polyol resin is added to the "pre-reacted" resin together with a tertiary amine catalyst and water as a blowing agent, the polymerization proceeds slowly enough to provide a stable foam body.

  16. THE EFFECT OF MODERATE AND HIGH-INTENSITY FATIGUE ON GROUNDSTROKE ACCURACY IN EXPERT AND NON-EXPERT TENNIS PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2013-06-01

    Full Text Available Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female and 17 non-expert (13 male, 4 female tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70% and high-intensities (90% set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test. Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA's revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player's achievement goal indicators. Future research is required to explore the effects of fatigue on

  17. Computer-aided analysis of star shot films for high-accuracy radiation therapy treatment units.

    Science.gov (United States)

    Depuydt, Tom; Penne, Rudi; Verellen, Dirk; Hrbacek, Jan; Lang, Stephanie; Leysen, Katrien; Vandevondel, Iwein; Poels, Kenneth; Reynders, Truus; Gevaert, Thierry; Duchateau, Michael; Tournel, Koen; Boussaer, Marlies; Cosentino, Dorian; Garibaldi, Cristina; Solberg, Timothy; De Ridder, Mark

    2012-05-21

    As mechanical stability of radiation therapy treatment devices has gone beyond sub-millimeter levels, there is a rising demand for simple yet highly accurate measurement techniques to support the routine quality control of these devices. A combination of using high-resolution radiosensitive film and computer-aided analysis could provide an answer. One generally known technique is the acquisition of star shot films to determine the mechanical stability of rotations of gantries and the therapeutic beam. With computer-aided analysis, mechanical performance can be quantified as a radiation isocenter radius size. In this work, computer-aided analysis of star shot film is further refined by applying an analytical solution for the smallest intersecting circle problem, in contrast to the gradient optimization approaches used until today. An algorithm is presented and subjected to a performance test using two different types of radiosensitive film, the Kodak EDR2 radiographic film and the ISP EBT2 radiochromic film. Artificial star shots with a priori known radiation isocenter size are used to determine the systematic errors introduced by the digitization of the film and the computer analysis. The estimated uncertainty on the isocenter size measurement with the presented technique was 0.04 mm (2σ) and 0.06 mm (2σ) for radiographic and radiochromic films, respectively. As an application of the technique, a study was conducted to compare the mechanical stability of O-ring gantry systems with C-arm-based gantries. In total ten systems of five different institutions were included in this study and star shots were acquired for gantry, collimator, ring, couch rotations and gantry wobble. It was not possible to draw general conclusions about differences in mechanical performance between O-ring and C-arm gantry systems, mainly due to differences in the beam-MLC alignment procedure accuracy. Nevertheless, the best performing O-ring system in this study, a BrainLab/MHI Vero system

  18. High accuracy station moving method for total station in submarine construction

    Directory of Open Access Journals (Sweden)

    MIN Shaosong

    2017-10-01

    Full Text Available [Objectives] When we measure submarine pressure hulls using a total station, it is essential to set several stations in order to complete the measurement of the whole cabin due to the complicated measuring environment. However, there are many restrictions related to the total station itself when moving stations, and it is also difficult to ensure measuring accuracy and satisfy the requirements of submarine measurement in complicated environments.[Methods] As such, a new station moving method is presented which can automatically establish standing relationships by measuring common points at every measuring position.[Results] This method can significantly improve accuracy and efficiency.[Conclusions] The experiment shows that the results of the new station moving method can meet sub-pixel precision and satisfy submarine measurement requirements with high accuracy.

  19. Silver Coating for High-Mass-Accuracy Imaging Mass Spectrometry of Fingerprints on Nanostructured Silicon.

    Science.gov (United States)

    Guinan, Taryn M; Gustafsson, Ove J R; McPhee, Gordon; Kobus, Hilton; Voelcker, Nicolas H

    2015-11-17

    Nanostructure imaging mass spectrometry (NIMS) using porous silicon (pSi) is a key technique for molecular imaging of exogenous and endogenous low molecular weight compounds from fingerprints. However, high-mass-accuracy NIMS can be difficult to achieve as time-of-flight (ToF) mass analyzers, which dominate the field, cannot sufficiently compensate for shifts in measured m/z values. Here, we show internal recalibration using a thin layer of silver (Ag) sputter-coated onto functionalized pSi substrates. NIMS peaks for several previously reported fingerprint components were selected and mass accuracy was compared to theoretical values. Mass accuracy was improved by more than an order of magnitude in several cases. This straightforward method should form part of the standard guidelines for NIMS studies for spatial characterization of small molecules.

  20. Software-based hybrid perfusion SPECT/CT provides diagnostic accuracy when other pulmonary embolism imaging is indeterminate

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Nishant; Xie, Karen; Mar, Winnie; Anderson, Thomas M.; Carney, Benjamin; Mehta, Nikhil; Machado, Roberto; Blend, Michael J.; Lu, Yang [University of Illinois Hospital and Health Sciences System, Chicago (Korea, Republic of)

    2015-12-15

    To investigate the diagnostic performance of perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) in patients suspected to have pulmonary embolism (PE) but with indeterminate computed tomographic pulmonary angiography (CTPA) or planar ventilation/perfusion (V/Q) scans. This retrospective study included two groups of patients. Group I consisted of 49 patients with nondiagnostic CTPA. These 49 patients underwent subsequent V/Q scans. Further Q-SPECTs were obtained in patients with indeterminate planar images and fused with existing CTPA. Group II consisted of 182 non-CTPA patients with indeterminate V/Q scans. These 182 patients underwent further Q-SPECT and separate noncontrast low-dose CT chest. Fusion Q-SPECT/CT scans were obtained through FDA-approved software and interpreted according to published criteria as positive, negative, or indeterminate for PE. Upon retrospective analyses, the final diagnosis was made using composite reference standards including all available clinical and imaging information for at least 6-month follow-up. In group I patients, 1 was positive, 24 were negative, and another 24 (49 %, 24/49) were indeterminate. In the subsequent 24 Q-SPECT/CTPAs, 4 were positive, 19 were negative, and 1 was indeterminate (4.2 %, 1/24). In group II patients, 9 (4.9 %, 9/182) were indeterminate, 33 were positive, and 140 were negative. The combined nondiagnostic rate for Q-SPECT/CT was only 4.9 % (10/206). There was six false-negative and one false-positive Q-SPECT/CT examinations. The sensitivity, specificity, and positive and negative predictive value of Q-SPECT/CT were 85.7 % (36/42), 99.4 % (153/154), 97.3 % (36/37) and 96.2 % (153/159), respectively. Q-SPECT/CT improves the diagnostic rate with promising accuracy in diagnosing PE that yields a satisfactory clinical verdict, especially when the CTPA and planar V/Q scan are indeterminate.

  1. A high accuracy algorithm of displacement measurement for a micro-positioning stage

    OpenAIRE

    Xiang Zhang; Xianmin Zhang; Heng Wu; Jinqiang Gan; Hai Li

    2017-01-01

    A high accuracy displacement measurement algorithm for a two degrees of freedom compliant precision micro-positioning stage is proposed based on the computer micro-vision technique. The algorithm consists of an integer-pixel and a subpixel matching procedure. Series of simulations are conducted to verify the proposed method. The results show that the proposed algorithm possesses the advantages of high precision and stability, the resolution can attain to 0.01 pixel theoretically. In addition,...

  2. Accuracy of Answers Provided by Digital/Face-to-Face Reference Services in Japanese Public Libraries and Q & A Sites

    Science.gov (United States)

    Tsuji, Keita; To, Haruna; Hara, Atsuyuki

    2011-01-01

    We asked the same 60 questions using DRS (digital reference services) in Japanese public libraries, face-to-face reference services and Q & A (question and answer) sites. It was found that: (1) The correct answer ratio of DRS is higher than that of Q & A sites; (2) DRS takes longer to provide answers as compared to Q & A sites; and (3)…

  3. High-density marker imputation accuracy in sixteen French cattle breeds.

    Science.gov (United States)

    Hozé, Chris; Fouilloux, Marie-Noëlle; Venot, Eric; Guillaume, François; Dassonneville, Romain; Fritz, Sébastien; Ducrocq, Vincent; Phocas, Florence; Boichard, Didier; Croiseau, Pascal

    2013-09-03

    Genotyping with the medium-density Bovine SNP50 BeadChip® (50K) is now standard in cattle. The high-density BovineHD BeadChip®, which contains 777,609 single nucleotide polymorphisms (SNPs), was developed in 2010. Increasing marker density increases the level of linkage disequilibrium between quantitative trait loci (QTL) and SNPs and the accuracy of QTL localization and genomic selection. However, re-genotyping all animals with the high-density chip is not economically feasible. An alternative strategy is to genotype part of the animals with the high-density chip and to impute high-density genotypes for animals already genotyped with the 50K chip. Thus, it is necessary to investigate the error rate when imputing from the 50K to the high-density chip. Five thousand one hundred and fifty three animals from 16 breeds (89 to 788 per breed) were genotyped with the high-density chip. Imputation error rates from the 50K to the high-density chip were computed for each breed with a validation set that included the 20% youngest animals. Marker genotypes were masked for animals in the validation population in order to mimic 50K genotypes. Imputation was carried out using the Beagle 3.3.0 software. Mean allele imputation error rates ranged from 0.31% to 2.41% depending on the breed. In total, 1980 SNPs had high imputation error rates in several breeds, which is probably due to genome assembly errors, and we recommend to discard these in future studies. Differences in imputation accuracy between breeds were related to the high-density-genotyped sample size and to the genetic relationship between reference and validation populations, whereas differences in effective population size and level of linkage disequilibrium showed limited effects. Accordingly, imputation accuracy was higher in breeds with large populations and in dairy breeds than in beef breeds. More than 99% of the alleles were correctly imputed if more than 300 animals were genotyped at high-density. No

  4. About accuracy of the discrimination parameter estimation for the dual high-energy method

    Science.gov (United States)

    Osipov, S. P.; Chakhlov, S. V.; Osipov, O. S.; Shtein, A. M.; Strugovtsev, D. V.

    2015-04-01

    A set of the mathematical formulas to estimate the accuracy of discrimination parameters for two implementations of the dual high energy method - by the effective atomic number and by the level lines is given. The hardware parameters which influenced on the accuracy of the discrimination parameters are stated. The recommendations to form the structure of the high energy X-ray radiation impulses are formulated. To prove the applicability of the proposed procedure there were calculated the statistical errors of the discrimination parameters for the cargo inspection system of the Tomsk polytechnic university on base of the portable betatron MIB-9. The comparison of the experimental estimations and the theoretical ones of the discrimination parameter errors was carried out. It proved the practical applicability of the algorithm to estimate the discrimination parameter errors for the dual high energy method.

  5. Automated, high accuracy classification of Parkinsonian disorders: a pattern recognition approach.

    Directory of Open Access Journals (Sweden)

    Andre F Marquand

    Full Text Available Progressive supranuclear palsy (PSP, multiple system atrophy (MSA and idiopathic Parkinson's disease (IPD can be clinically indistinguishable, especially in the early stages, despite distinct patterns of molecular pathology. Structural neuroimaging holds promise for providing objective biomarkers for discriminating these diseases at the single subject level but all studies to date have reported incomplete separation of disease groups. In this study, we employed multi-class pattern recognition to assess the value of anatomical patterns derived from a widely available structural neuroimaging sequence for automated classification of these disorders. To achieve this, 17 patients with PSP, 14 with IPD and 19 with MSA were scanned using structural MRI along with 19 healthy controls (HCs. An advanced probabilistic pattern recognition approach was employed to evaluate the diagnostic value of several pre-defined anatomical patterns for discriminating the disorders, including: (i a subcortical motor network; (ii each of its component regions and (iii the whole brain. All disease groups could be discriminated simultaneously with high accuracy using the subcortical motor network. The region providing the most accurate predictions overall was the midbrain/brainstem, which discriminated all disease groups from one another and from HCs. The subcortical network also produced more accurate predictions than the whole brain and all of its constituent regions. PSP was accurately predicted from the midbrain/brainstem, cerebellum and all basal ganglia compartments; MSA from the midbrain/brainstem and cerebellum and IPD from the midbrain/brainstem only. This study demonstrates that automated analysis of structural MRI can accurately predict diagnosis in individual patients with Parkinsonian disorders, and identifies distinct patterns of regional atrophy particularly useful for this process.

  6. A fast and high accuracy numerical simulation algorithm of the polymer spherulite at the mesoscale Level

    Science.gov (United States)

    Liu, Yongzhi; Geng, Tie; (Tom Turng, Lih-Sheng; Liu, Chuntai; Cao, Wei; Shen, Changyu

    2017-09-01

    In the multiscale numerical simulation of polymer crystallization during the processing period, flow and temperature of the polymer melt are simulated on the macroscale level, while nucleation and growth of the spherulite are simulated at the mesoscale level. As a part of the multiscale simulation, the meso-simulation requires a fast solving speed because the meso-simulation software must be run several times in every macro-element at each macro-step. Meanwhile, the accuracy of the calculation results is also very important. It is known that the simulation geometry of crystallization includes planar (2D) and three-dimensional space (3D). The 3D calculations are more accurate but more expensive because of the long CPU time consumed. On the contrary, 2D calculations are always much faster but lower in accuracy. To reach the desirable speed and high accuracy at the same time, an algorithm is presented, in which the Delesse law coupled with the Monte Carlo method and pixel method are employed to simulate the nucleation, growth, and impingement of the polymer spherulite at the mesoscale level. Based on this algorithm, a software is developed with the Visual C++ language, and its numerical examples’ results prove that the solving speed of this algorithm is as fast as the 2D classical simulation and the calculation accuracy is at the same level as the 3D simulation.

  7. High accuracy position response calibration method for a micro-channel plate ion detector

    Energy Technology Data Exchange (ETDEWEB)

    Hong, R., E-mail: hongran@uw.edu [Department of Physics and Center for Experimental Nuclear Physics and Astrophysics, University of Washington, Seattle, WA 98195 (United States); High Energy Physics Division, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Leredde, A. [Physics Division, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Bagdasarova, Y. [Department of Physics and Center for Experimental Nuclear Physics and Astrophysics, University of Washington, Seattle, WA 98195 (United States); Fléchard, X. [Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, LPC Caen, 14000 Caen (France); García, A. [Department of Physics and Center for Experimental Nuclear Physics and Astrophysics, University of Washington, Seattle, WA 98195 (United States); Müller, P. [Physics Division, Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Knecht, A. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Liénard, E. [Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, LPC Caen, 14000 Caen (France); Kossin, M. [Department of Physics, Department of Physics, University of Maryland, College Park, MD 20742 (United States); Sternberg, M.G.; Swanson, H.E.; Zumwalt, D.W. [Department of Physics and Center for Experimental Nuclear Physics and Astrophysics, University of Washington, Seattle, WA 98195 (United States)

    2016-11-01

    We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an in situ calibration mask, an accuracy of 8 µm and a resolution of 85 µm (FWHM) have been achieved for MeV-scale α particles and ions with energies of ∼10 keV. At this level of accuracy, the difference between the MCP position responses to high-energy α particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear β-decay experiment.

  8. High accuracy position response calibration method for a micro-channel plate ion detector

    Science.gov (United States)

    Hong, R.; Leredde, A.; Bagdasarova, Y.; Fléchard, X.; García, A.; Müller, P.; Knecht, A.; Liénard, E.; Kossin, M.; Sternberg, M. G.; Swanson, H. E.; Zumwalt, D. W.

    2016-11-01

    We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an in situ calibration mask, an accuracy of 8 μm and a resolution of 85 μm (FWHM) have been achieved for MeV-scale α particles and ions with energies of ∼10 keV. At this level of accuracy, the difference between the MCP position responses to high-energy α particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear β-decay experiment.

  9. Cause and Cure - Deterioration in Accuracy of CFD Simulations With Use of High-Aspect-Ratio Triangular Tetrahedral Grids

    Science.gov (United States)

    Chang, Sin-Chung; Chang, Chau-Lyan; Venkatachari, Balaji Shankar

    2017-01-01

    Traditionally high-aspect ratio triangular/tetrahedral meshes are avoided by CFD re-searchers in the vicinity of a solid wall, as it is known to reduce the accuracy of gradient computations in those regions and also cause numerical instability. Although for certain complex geometries, the use of high-aspect ratio triangular/tetrahedral elements in the vicinity of a solid wall can be replaced by quadrilateral/prismatic elements, ability to use triangular/tetrahedral elements in such regions without any degradation in accuracy can be beneficial from a mesh generation point of view. The benefits also carry over to numerical frameworks such as the space-time conservation element and solution element (CESE), where triangular/tetrahedral elements are the mandatory building blocks. With the requirement of the CESE method in mind, a rigorous mathematical framework that clearly identities the reason behind the difficulties in use of such high-aspect ratio triangular/tetrahedral elements is presented here. As will be shown, it turns out that the degree of accuracy deterioration of gradient computation involving a triangular element is hinged on the value of its shape factor Gamma def = sq sin Alpha1 + sq sin Alpha2 + sq sin Alpha3, where Alpha1; Alpha2 and Alpha3 are the internal angles of the element. In fact, it is shown that the degree of accuracy deterioration increases monotonically as the value of Gamma decreases monotonically from its maximal value 9/4 (attained by an equilateral triangle only) to a value much less than 1 (associated with a highly obtuse triangle). By taking advantage of the fact that a high-aspect ratio triangle is not necessarily highly obtuse, and in fact it can have a shape factor whose value is close to the maximal value 9/4, a potential solution to avoid accuracy deterioration of gradient computation associated with a high-aspect ratio triangular grid is given. Also a brief discussion on the extension of the current mathematical framework to the

  10. ANALYSIS OF METHODS PROVIDING ACCURACY FOR TOOLS AND TECHNIQUES VIBRATION MEASUREMENT IN THE PROCESS OF MAINTAINING AIRWORTHINESS OF AIRCRAFT

    Directory of Open Access Journals (Sweden)

    Anatoliy Alexandrovich Bogoyavlenskiy

    2017-01-01

    Full Text Available On the basis of system approach the structure of the aviation activity areas on air transport related to monitoring and measurements of vibration parameters is presented.The technology analysis of laboratory tests of the onboard equipment control of vibration parameters is carried out. The issues related to ensuring the unity of measurements of vibration parameters are researched and summarized.While dealing with the works on metrological certification described in the article, the risks arising from aviation activity on air transport are taken into account. The certification methods of measuring channels of vibration parametersused on stands for testing GTE at the repairing of aircraft engines are developed. The methods are implemented when con- ducting initial and periodic certifications of test benches for twelve types of aircraft GTE in repair organizations. The reliability of the results of the conducted research due to the fact that they were carried out with the use of certified measure- ment equipment, included in the State register of measuring instruments. The research is conducted for a sufficiently high statistical confidence level with the boundaries 0.95. The studies have shown that running on air transport measurements of vibration parameters are metrologically se- cured, the unity of measurements and their traceability from the national primary reference to special measuring instru- ments, test equipment, and onboard controls of the aircraft is maintained.

  11. High-accuracy water potential energy surface for the calculation of infrared spectra.

    Science.gov (United States)

    Mizus, Irina I; Kyuberis, Aleksandra A; Zobov, Nikolai F; Makhnev, Vladimir Yu; Polyansky, Oleg L; Tennyson, Jonathan

    2018-03-13

    Transition intensities for small molecules such as water and CO 2 can now be computed with such high accuracy that they are being used to systematically replace measurements in standard databases. These calculations use high-accuracy ab initio dipole moment surfaces and wave functions from spectroscopically determined potential energy surfaces (PESs). Here, an extra high-accuracy PES of the water molecule (H 2 16 O) is produced starting from an ab initio PES which is then refined to empirical rovibrational energy levels. Variational nuclear motion calculations using this PES reproduce the fitted energy levels with a standard deviation of 0.011 cm -1 , approximately three times their stated uncertainty. The use of wave functions computed with this refined PES is found to improve the predicted transition intensities for selected (problematic) transitions. A new room temperature line list for H 2 16 O is presented. It is suggested that the associated set of line intensities is the most accurate available to date for this species.This article is part of the theme issue 'Modern theoretical chemistry'. © 2018 The Author(s).

  12. High accuracy position adjustment and vibration isolation actuator with the controlled ferrofluid

    Science.gov (United States)

    Wu, Shuai; Li, Chunfang; Zhao, Xiangyu; Jiao, Zongxia

    2017-11-01

    An actuator for microposition adjustment and vibration isolation using the controlled ferrofluid is reported in this letter. The proposed actuator levitates on the ferrofluid which is affected by the combined dynamic magnetic field which is formed by coupling a permanent magnetic field with a controlled electromagnetic field. A controlled electromagnetic field is superposed on the permanent magnetic field in order to change the shape of the ferrofluid to ultimately move the actuator. The experimental results indicate that the proposed actuator can adjust the position with high accuracy and has a good dynamic performance. The proposed actuator can bear over 2 N loads, and the positioning accuracy is within 0.1 μ m. The stroke of the actuator is about of ±30 μ m with no load, and the stroke increases to ±75 μ m at 2 N load. Its dynamic band with -3 dB amplitude attenuation and -90° phase is over 40 Hz. In addition, the displacement has a very good linear relationship with the input current. The results also demonstrate that the actuator can isolate vibration in a wide frequency range, as the low frequency vibration can be compensated by the active motion control, while the high frequency vibration can be attenuated by the elasticity and damping effects of the ferrofluid. Consequently, the proposed actuator has a significant potential for applications where the high accuracy micro-position adjustment and vibration isolation are needed.

  13. Accuracy of GPS devices for measuring high-intensity running in field-based team sports.

    Science.gov (United States)

    Rampinini, E; Alberti, G; Fiorenza, M; Riggio, M; Sassi, R; Borges, T O; Coutts, A J

    2015-01-01

    We compared the accuracy of 2 GPS systems with different sampling rates for the determination of distances covered at high-speed and metabolic power derived from a combination of running speed and acceleration. 8 participants performed 56 bouts of shuttle intermittent running wearing 2 portable GPS devices (SPI-Pro, GPS-5 Hz and MinimaxX, GPS-10 Hz). The GPS systems were compared with a radar system as a criterion measure. The variables investigated were: total distance (TD), high-speed distance (HSR>4.17 m·s(-1)), very high-speed distance (VHSR>5.56 m·s(-1)), mean power (Pmean), high metabolic power (HMP>20 W·kg(-1)) and very high metabolic power (VHMP>25 W·kg(-1)). GPS-5 Hz had low error for TD (2.8%) and Pmean (4.5%), while the errors for the other variables ranged from moderate to high (7.5-23.2%). GPS-10 Hz demonstrated a low error for TD (1.9%), HSR (4.7%), Pmean (2.4%) and HMP (4.5%), whereas the errors for VHSR (10.5%) and VHMP (6.2%) were moderate. In general, GPS accuracy increased with a higher sampling rate, but decreased with increasing speed of movement. Both systems could be used for calculating TD and Pmean, but they cannot be used interchangeably. Only GPS-10 Hz demonstrated a sufficient level of accuracy for quantifying distance covered at higher speeds or time spent at very high power. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Implementation of High Time Delay Accuracy of Ultrasonic Phased Array Based on Interpolation CIC Filter

    Directory of Open Access Journals (Sweden)

    Peilu Liu

    2017-10-01

    Full Text Available In order to improve the accuracy of ultrasonic phased array focusing time delay, analyzing the original interpolation Cascade-Integrator-Comb (CIC filter, an 8× interpolation CIC filter parallel algorithm was proposed, so that interpolation and multichannel decomposition can simultaneously process. Moreover, we summarized the general formula of arbitrary multiple interpolation CIC filter parallel algorithm and established an ultrasonic phased array focusing time delay system based on 8× interpolation CIC filter parallel algorithm. Improving the algorithmic structure, 12.5% of addition and 29.2% of multiplication was reduced, meanwhile the speed of computation is still very fast. Considering the existing problems of the CIC filter, we compensated the CIC filter; the compensated CIC filter’s pass band is flatter, the transition band becomes steep, and the stop band attenuation increases. Finally, we verified the feasibility of this algorithm on Field Programming Gate Array (FPGA. In the case of system clock is 125 MHz, after 8× interpolation filtering and decomposition, time delay accuracy of the defect echo becomes 1 ns. Simulation and experimental results both show that the algorithm we proposed has strong feasibility. Because of the fast calculation, small computational amount and high resolution, this algorithm is especially suitable for applications with high time delay accuracy and fast detection.

  15. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, S.A.; Assadsangabi, R.; Hajmomenian, M.; Vossough, A. [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Santi, M. [Perelman School of Medicine of the University of Pennsylvania, Department of Pathology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States)

    2015-05-01

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  16. Assessment of diagnostic accuracy of high-resolution ultrasonography in determination of temporomandibular joint internal derangement

    Directory of Open Access Journals (Sweden)

    Byahatti Sujata

    2010-01-01

    Full Text Available Aim : The aim of this study was to determine the value of dynamic high-resolution ultrasonography (HR-US in the evaluation of internal derangements of a temporomandibular joint (TMJ in the open and closed mouth position. Settings and Design : The study designed to collect the sample from the Outpatient Department of Oral Medicine and Radiology at GDC, Bangalore. Patients with pain, clicking, deviation, and tenderness were included in the study as a symptomatic group. The asymptomatic group was free of any symptoms. Materials and Methods : Maximum mandibular range of motion (Open and Closed was performed during HR-US of TMJ in 100 consecutive patients, (50 symptomatic and 50 asymptomatic cases, a total of 400 joints, with 200 joints in the right and left closed and open mouth position;36 males and 64 females; age range, 16 - 50 years; mean age 27.56 years. Subsequently, the entire group, after clinical diagnosis, went for HR-US. Sonography confirmed the diagnosis by showing internal derangement in 34 (68% of the symptomatic group and the remaining 16 (32% patients failed to show any derangement. In the asymptomatic group 40 patients did not show any pathology associated with TMJ, whereas, 10 patients showed internal derangement. The data obtained was analyzed statistically. Results : HR-US performed during the maximal range of motion (Open and Closed helped to detect 34 instances (68 joints of internal derangement, which were true positive cases, whereas, 16 patients (32 joints showed a false positive finding for internal derangement (ID. The results obtained showed a sensitivity of 64%, specificity of 88%, positive predictive value of 84%, and a negative predictive value of 71%, with an accuracy of 76%. Conclusions : Dynamic HR-US being non-invasive can provide valuable information about internal derangement of the TMJ in mandibular closed mouth than open mouth position.

  17. High Accuracy Attitude Control System Design for Satellite with Flexible Appendages

    Directory of Open Access Journals (Sweden)

    Wenya Zhou

    2014-01-01

    Full Text Available In order to realize the high accuracy attitude control of satellite with flexible appendages, attitude control system consisting of the controller and structural filter was designed. When the low order vibration frequency of flexible appendages is approximating the bandwidth of attitude control system, the vibration signal will enter the control system through measurement device to bring impact on the accuracy or even the stability. In order to reduce the impact of vibration of appendages on the attitude control system, the structural filter is designed in terms of rejecting the vibration of flexible appendages. Considering the potential problem of in-orbit frequency variation of the flexible appendages, the design method for the adaptive notch filter is proposed based on the in-orbit identification technology. Finally, the simulation results are given to demonstrate the feasibility and effectiveness of the proposed design techniques.

  18. Locating very high energy gamma ray sources with arc minute accuracy

    Science.gov (United States)

    Akerlof, C. W.; Cawley, M. F.; Chantell, M.; Fegan, D. J.; Harris, K.; Hillas, A. M.; Jennings, D. G.; Lamb, R. C.; Lawrence, M. A.; Lang, M. J.

    1992-01-01

    The angular accuracy of gamma-ray detectors is intrinsically limited by the physical processes involved in photon detection. Although a number of point-like sources were detected by the COS-B satellite, only two were unambiguously identified by time signature with counterparts at longer wavelengths. By taking advantage of the extended longitudinal structure of Very High Energy gamma-ray showers, measurements in the TeV energy range can pinpoint source coordinates to arc minute accuracy. This was demonstrated using Cerenkov air shower imaging techniques. With two telescopes in coincidence, the individual event circular probable error will be 0.13 deg. The half-cone angle of the field of view is effectively 1 deg.

  19. High-accuracy determination of the neutron flux at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, M.; Colonna, N.; Mastromarco, M.; Meaze, M.; Tagliente, G.; Variale, V. [Sezione di Bari, INFN, Bari (Italy); Guerrero, C.; Andriamonje, S.; Boccone, V.; Brugger, M.; Calviani, M.; Cerutti, F.; Chin, M.; Ferrari, A.; Kadi, Y.; Losito, R.; Versaci, R.; Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); National Technical University of Athens (NTUA), Athens (Greece); Tarrio, D.; Duran, I.; Leal-Cidoncha, E.; Paradela, C. [Universidade de Santiago de Compostela, Santiago (Spain); Altstadt, S.; Goebel, K.; Langer, C.; Reifarth, R.; Schmidt, S.; Weigand, M. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (Germany); Andrzejewski, J.; Marganiec, J.; Perkowski, J. [Uniwersytet Lodzki, Lodz (Poland); Audouin, L.; Leong, L.S.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Becares, V.; Cano-Ott, D.; Garcia, A.R.; Gonzalez-Romero, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Becvar, F.; Krticka, M.; Kroll, J.; Valenta, S. [Charles University, Prague (Czech Republic); Belloni, F.; Fraval, K.; Gunsing, F.; Lampoudis, C.; Papaevangelou, T. [Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E.; Chiaveri, E. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Billowes, J.; Ware, T.; Wright, T. [University of Manchester, Manchester (United Kingdom); Bosnar, D.; Zugec, P. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Calvino, F.; Cortes, G.; Gomez-Hornillos, M.B.; Riego, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Carrapico, C.; Goncalves, I.F.; Sarmento, R.; Vaz, P. [Universidade Tecnica de Lisboa, Instituto Tecnologico e Nuclear, Instituto Superior Tecnico, Lisboa (Portugal); Cortes-Giraldo, M.A.; Praena, J.; Quesada, J.M.; Sabate-Gilarte, M. [Universidad de Sevilla, Sevilla (Spain); Diakaki, M.; Karadimos, D.; Kokkoris, M.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Kivel, N.; Schumann, D.; Steinegger, P. [Paul Scherrer Institut, Villigen PSI (Switzerland); Dzysiuk, N.; Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Rome (Italy); Eleftheriadis, C.; Manousos, A. [Aristotle University of Thessaloniki, Thessaloniki (Greece); Ganesan, S.; Gurusamy, P.; Saxena, A. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Griesmayer, E.; Jericha, E.; Leeb, H. [Technische Universitaet Wien, Atominstitut, Wien (AT); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Jenkins, D.G.; Vermeulen, M.J. [University of York, Heslington, York (GB); Kaeppeler, F. [Institut fuer Kernphysik, Karlsruhe Institute of Technology, Campus Nord, Karlsruhe (DE); Koehler, P. [Oak Ridge National Laboratory (ORNL), Oak Ridge (US); Lederer, C. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE); University of Vienna, Faculty of Physics, Vienna (AT); Massimi, C.; Mingrone, F.; Vannini, G. [Universita di Bologna (IT); INFN, Sezione di Bologna, Dipartimento di Fisica, Bologna (IT); Mengoni, A.; Ventura, A. [Agenzia nazionale per le nuove tecnologie, l' energia e lo sviluppo economico sostenibile (ENEA), Bologna (IT); Milazzo, P.M. [Sezione di Trieste, INFN, Trieste (IT); Mirea, M. [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Mondalaers, W.; Plompen, A.; Schillebeeckx, P. [Institute for Reference Materials and Measurements, European Commission JRC, Geel (BE); Pavlik, A.; Wallner, A. [University of Vienna, Faculty of Physics, Vienna (AT); Rauscher, T. [University of Basel, Department of Physics and Astronomy, Basel (CH); Roman, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Laboratori Nazionali del Gran Sasso dell' INFN, Assergi (AQ) (IT); Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE)

    2013-12-15

    The neutron flux of the n{sub T}OF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n{sub T}OF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n{sub T}OF. An unexpected anomaly in the neutron-induced fission cross section of {sup 235}U is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties. (orig.)

  20. High-accuracy determination of the neutron flux at n_TOF

    Science.gov (United States)

    Barbagallo, M.; Guerrero, C.; Tsinganis, A.; Tarrío, D.; Altstadt, S.; Andriamonje, S.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Bosnar, D.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Domingo-Pardo, C.; Duran, I.; Dressler, R.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A. R.; Giubrone, G.; Göbel, K.; Gómez-Hornillos, M. B.; Gonçalves, I. F.; González-Romero, E.; Griesmayer, E.; Gunsing, F.; Gurusamy, P.; Hernández-Prieto, A.; Jenkins, D. G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Kivel, N.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Leong, L. S.; Losito, R.; Manousos, A.; Marganiec, J.; Martınez, T.; Massimi, C.; Mastinu, P. F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Papaevangelou, T.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J. M.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sabate-Gilarte, M.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Steinegger, P.; Tagliente, G.; Tain, J. L.; Tassan-Got, L.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M. J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.; Žugec, P.

    2013-12-01

    The neutron flux of the n_TOF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n_TOF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n_TOF. An unexpected anomaly in the neutron-induced fission cross section of 235U is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties.

  1. Towards Building Reliable, High-Accuracy Solar Irradiance Database For Arid Climates

    Science.gov (United States)

    Munawwar, S.; Ghedira, H.

    2012-12-01

    based models and tools can subsequently be recalibrated or improvised to address the unique features of characteristically high aerosol load, frequent dust episodes and yet, typically clear skies, in the Gulf's primarily arid region. For example, though clouds are an important factor, radiative extinction in desert climates is primarily due to aerosols; a fact that needs to be taken into consideration since most of the existing solar radiation models are technically cloud-based. Satellite derived irradiance, although carrying a tag of uncertainties (5-10%), have special relevance in the Gulf due to lack of long-term data at the source of application. Satellite data can be merged or combined with short-term ground measurements, by various techniques available in the literature, to smooth out uncertainties in the data and build high-accuracy long-term solar irradiance profiles. Such concatenation is of particular interest to investors as it provides vital information on solar resource variability.

  2. A high-accuracy optical linear algebra processor for finite element applications

    Science.gov (United States)

    Casasent, D.; Taylor, B. K.

    1984-01-01

    Optical linear processors are computationally efficient computers for solving matrix-matrix and matrix-vector oriented problems. Optical system errors limit their dynamic range to 30-40 dB, which limits their accuray to 9-12 bits. Large problems, such as the finite element problem in structural mechanics (with tens or hundreds of thousands of variables) which can exploit the speed of optical processors, require the 32 bit accuracy obtainable from digital machines. To obtain this required 32 bit accuracy with an optical processor, the data can be digitally encoded, thereby reducing the dynamic range requirements of the optical system (i.e., decreasing the effect of optical errors on the data) while providing increased accuracy. This report describes a new digitally encoded optical linear algebra processor architecture for solving finite element and banded matrix-vector problems. A linear static plate bending case study is described which quantities the processor requirements. Multiplication by digital convolution is explained, and the digitally encoded optical processor architecture is advanced.

  3. High density marker panels, SNPs prioritizing and accuracy of genomic selection.

    Science.gov (United States)

    Chang, Ling-Yun; Toghiani, Sajjad; Ling, Ashley; Aggrey, Sammy E; Rekaya, Romdhane

    2018-01-05

    The availability of high-density (HD) marker panels, genome wide variants and sequence data creates an unprecedented opportunity to dissect the genetic basis of complex traits, enhance genomic selection (GS) and identify causal variants of disease. The disproportional increase in the number of parameters in the genetic association model compared to the number of phenotypes has led to further deterioration in statistical power and an increase in co-linearity and false positive rates. At best, HD panels do not significantly improve GS accuracy and, at worst, reduce accuracy. This is true for both regression and variance component approaches. To remedy this situation, some form of single nucleotide polymorphisms (SNP) filtering or external information is needed. Current methods for prioritizing SNP markers (i.e. BayesB, BayesCπ) are sensitive to the increased co-linearity in HD panels which could limit their performance. In this study, the usefulness of FST, a measure of allele frequency variation among populations, as an external source of information in GS was evaluated. A simulation was carried out for a trait with heritability of 0.4. Data was divided into three subpopulations based on phenotype distribution (bottom 5%, middle 90%, top 5%). Marker data were simulated to mimic a 770 K and 1.5 million SNP marker panel. A ten-chromosome genome with 200 K and 400 K SNPs was simulated. Several scenarios with varying distributions for the quantitative trait loci (QTL) effects were simulated. Using all 200 K markers and no filtering, the accuracy of genomic prediction was 0.77. When marker effects were simulated from a gamma distribution, SNPs pre-selected based on the 99.5, 99.0 and 97.5% quantile of the FST score distribution resulted in an accuracy of 0.725, 0.797, and 0.853, respectively. Similar results were observed under other simulation scenarios. Clearly, the accuracy obtained using all SNPs can be easily achieved using only 0.5 to 1% of all markers. These

  4. High accuracy measurements of magnetic field integrals for the european XFEL undulator systems

    Science.gov (United States)

    Wolff-Fabris, Frederik; Viehweger, Marc; Li, Yuhui; Pflüger, Joachim

    2016-10-01

    Two high accuracy moving wire (MW) measurement systems based on stretched wire technique were built for the European XFEL (XFEL.EU). They were dedicated to monitor, tune and improve the magnetic field integrals properties during the serial production of the undulator segments, phase shifters and air coil correctors for XFEL.EU. For the magnetic tuning of phase shifters and the calibration of the air coils correctors a short portable MW measurement bench was built to measure first field integrals in short devices with magnetic length of less than about 300 mm and with an ultimate accuracy much better than 1 G cm (0.001 T mm). A long MW measurement setup was dedicated to obtain the total first and second field integrals on the 5-meters long undulator segments with accuracy of about 4 G cm (0.004 T mm) and 2000 G cm2 (20 T mm2) for the 1st and 2nd field integrals, respectively. Using these data a method was developed to compute the proper corrections for the air coils correctors used at both extremities so that zero first and second field integrals for an undulator segment are obtained. It is demonstrated that charging air coils correctors with these corrections results in near zero effect to the electron trajectory in the undulator systems and consequently no negative impact on the self-amplified spontaneous emission (SASE) process should occur.

  5. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  6. A very low noise, high accuracy, programmable voltage source for low frequency noise measurements

    Science.gov (United States)

    Scandurra, Graziella; Giusi, Gino; Ciofi, Carmine

    2014-04-01

    In this paper an approach for designing a programmable, very low noise, high accuracy voltage source for biasing devices under test in low frequency noise measurements is proposed. The core of the system is a supercapacitor based two pole low pass filter used for filtering out the noise produced by a standard DA converter down to 100 mHz with an attenuation in excess of 40 dB. The high leakage current of the supercapacitors, however, introduces large DC errors that need to be compensated in order to obtain high accuracy as well as very low output noise. To this end, a proper circuit topology has been developed that allows to considerably reduce the effect of the supercapacitor leakage current on the DC response of the system while maintaining a very low level of output noise. With a proper design an output noise as low as the equivalent input voltage noise of the OP27 operational amplifier, used as the output buffer of the system, can be obtained with DC accuracies better that 0.05% up to the maximum output of 8 V. The expected performances of the proposed voltage source have been confirmed both by means of SPICE simulations and by means of measurements on actual prototypes. Turn on and stabilization times for the system are of the order of a few hundred seconds. These times are fully compatible with noise measurements down to 100 mHz, since measurement times of the order of several tens of minutes are required in any case in order to reduce the statistical error in the measured spectra down to an acceptable level.

  7. A small and high accuracy gyro stabilization electro-optical platform

    Science.gov (United States)

    Qiu, Haitao; Han, Yonggen; Lv, Yanhong

    2008-10-01

    A high accuracy line-of-sight (LOS) Stabilization system based on digital control technology was designed. The current feedback closed-loop system was introduced which uses the CCD graphic and resolver to constitute the position closed-loop and uses the optic fiber gyro to constitute the rate closed-loop. In order to realize zero steady-state error of angular output in counteracting disturbance from carrier, a PII2 (proportional-integral-double integral) control scheme is proposed. The hardware configuration and software system is presented. Experimental results show that the system has perfect dynamic and static performance and the technical requirements were satisfied.

  8. High-accuracy mass determination of unstable nuclei with a Penning trap mass spectrometer

    CERN Multimedia

    2002-01-01

    The mass of a nucleus is its most fundamental property. A systematic study of nuclear masses as a function of neutron and proton number allows the observation of collective and single-particle effects in nuclear structure. Accurate mass data are the most basic test of nuclear models and are essential for their improvement. This is especially important for the astrophysical study of nuclear synthesis. In order to achieve the required high accuracy, the mass of ions captured in a Penning trap is determined via their cyclotron frequency $ \

  9. From journal to headline: the accuracy of climate science news in Danish high quality newspapers

    DEFF Research Database (Denmark)

    Vestergård, Gunver Lystbæk

    2011-01-01

    analysis to examine the accuracy of Danish high quality newspapers in quoting scientific publications from 1997 to 2009. Out of 88 articles, 46 contained inaccuracies though the majority was found to be insignificant and random. The study concludes that Danish broadsheet newspapers are ‘moderately......A significant number of mass media news stories on climate change quote scientific publications. However, the journalistic process of popularizing scientific research regarding climate change has been profoundly criticized for being manipulative and inaccurate. This preliminary study used content...

  10. High accuracy 234U(n,f cross section in the resonance energy region

    Directory of Open Access Journals (Sweden)

    Leal-Cidoncha E.

    2017-01-01

    Full Text Available New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f as reference. The recent evaluation of the 235U(n,f obtained with SAMMY by L. C. Leal et al. (these Proceedings, based on previous n_TOF data [1], has been used to calculate the 234U(n,f cross section through the 234U/235U ratio, being here compared with the results obtained by using the n_TOF neutron flux.

  11. High accuracy 234U(n,f) cross section in the resonance energy region

    Science.gov (United States)

    Leal-Cidoncha, E.; Durán, I.; Paradela, C.; Tassan-Got, L.; Audouin, L.; Leal, L. C.; Naour, C. Le; Noguere, G.; Tarrío, D.; Leong, L. S.; Altstadt, S.; Andrzejewski, J.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Bosnar, D.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A. R.; Giubrone, G.; Gómez-Hornillos, M. B.; Gonçalves, I. F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Hernández-Prieto, A.; Jenkins, D. G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Kivel, N.; Kokkoris, M.; Krtička, M.; Kroll, J.; Lampoudis, C.; Langer, C.; Lederer, C.; Leeb, H.; Losito, R.; Mallick, A.; Manousos, A.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P. F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Mondelaers, W.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J. M.; Rauscher, T.; Reifarth, R.; Riego, A.; Robles, M. S.; Roman, F.; Rubbia, C.; Sabaté-Gilarte, M.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Tagliente, G.; Tain, J. L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M. J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.; Žugec, P.

    2017-09-01

    New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f) as reference. The recent evaluation of the 235U(n,f) obtained with SAMMY by L. C. Leal et al. (these Proceedings), based on previous n_TOF data [1], has been used to calculate the 234U(n,f) cross section through the 234U/235U ratio, being here compared with the results obtained by using the n_TOF neutron flux.

  12. High Accuracy Three-dimensional Simulation of Micro Injection Moulded Parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Costa, F. S.; Hansen, Hans Nørgaard

    2011-01-01

    Micro injection moulding (μIM) is the key replication technology for high precision manufacturing of polymer micro products. Data analysis and simulations on micro-moulding experiments have been conducted during the present validation study. Detailed information about the μIM process was gathered...... and used to establish a reliable simulation methodology suitable for μIM parts. Various Simulation set-up parameters that have been considered in order to improve the simulation accuracy: injection speed profile, melt and mould temperatures, 3D mesh, material rheology, inertia effect and shrinkage...

  13. Reparable, high-density microelectronic module provides effective heat sink

    Science.gov (United States)

    Carlson, K. J.; Maytone, F. F.

    1967-01-01

    Reparable modular system is used for packaging microelectronic flat packs and miniature discrete components. This three-dimensional compartmented structure incorporates etched phosphor bronze sheets and frames with etched wire conductors. It provides an effective heat sink for electric power dissipation in the absence of convective cooling means.

  14. A new ultra-high-accuracy angle generator: current status and future direction

    Science.gov (United States)

    Guertin, Christian F.; Geckeler, Ralf D.

    2017-09-01

    Lack of an extreme high-accuracy angular positioning device available in the United States has left a gap in industrial and scientific efforts conducted there, requiring certain user groups to undertake time-consuming work with overseas laboratories. Specifically, in x-ray mirror metrology the global research community is advancing the state-of-the-art to unprecedented levels. We aim to fill this U.S. gap by developing a versatile high-accuracy angle generator as a part of the national metrology tool set for x-ray mirror metrology and other important industries. Using an established calibration technique to measure the errors of the encoder scale graduations for full-rotation rotary encoders, we implemented an optimized arrangement of sensors positioned to minimize propagation of calibration errors. Our initial feasibility research shows that upon scaling to a full prototype and including additional calibration techniques we can expect to achieve uncertainties at the level of 0.01 arcsec (50 nrad) or better and offer the immense advantage of a highly automatable and customizable product to the commercial market.

  15. High accuracy position method based on computer vision and error analysis

    Science.gov (United States)

    Chen, Shihao; Shi, Zhongke

    2003-09-01

    The study of high accuracy position system is becoming the hotspot in the field of autocontrol. And positioning is one of the most researched tasks in vision system. So we decide to solve the object locating by using the image processing method. This paper describes a new method of high accuracy positioning method through vision system. In the proposed method, an edge-detection filter is designed for a certain running condition. Here, the filter contains two mainly parts: one is image-processing module, this module is to implement edge detection, it contains of multi-level threshold self-adapting segmentation, edge-detection and edge filter; the other one is object-locating module, it is to point out the location of each object in high accurate, and it is made up of medium-filtering and curve-fitting. This paper gives some analysis error for the method to prove the feasibility of vision in position detecting. Finally, to verify the availability of the method, an example of positioning worktable, which is using the proposed method, is given at the end of the paper. Results show that the method can accurately detect the position of measured object and identify object attitude.

  16. High School Child Development Courses Provide a Valuable Apprenticeship

    Science.gov (United States)

    McCombie, Sally M.

    2009-01-01

    The current media are laden with reports of the many significant problems facing today's youth. In fact, parenting has become a national topic of discussion. Parenting instruction, a responsibility that had previously rested in the home, has become part of educational curricula. Courses in child development are offered for high school students in…

  17. High-accuracy process based on the corrective calibration of removal function in the magnetorheological finishing

    Science.gov (United States)

    Zhong, Xianyun; Fan, Bin; Wu, Fan

    2017-08-01

    The corrective calibration of the removal function plays an important role in the magnetorheological finishing (MRF) high-accuracy process. This paper mainly investigates the asymmetrical characteristic of the MRF removal function shape and further analyzes its influence on the surface residual error by means of an iteration algorithm and simulations. By comparing the ripple errors and convergence ratios based on the ideal MRF tool function and the deflected tool function, the mathematical models for calibrating the deviation of horizontal and flowing directions are presented. Meanwhile, revised mathematical models for the coordinate transformation of an MRF machine is also established. Furthermore, a Ø140-mm fused silica plane and a Ø196 mm, f/1∶1, fused silica concave sphere samples are taken as the experiments. After two runs, the plane mirror final surface error reaches PV 17.7 nm, RMS 1.75 nm, and the polishing time is 16 min in total; after three runs, the sphere mirror final surfer error reaches RMS 2.7 nm and the polishing time is 70 min in total. The convergence ratios are 96.2% and 93.5%, respectively. The spherical simulation error and the polishing result are almost consistent, which fully validate the efficiency and feasibility of the calibration method of MRF removal function error using for the high-accuracy subaperture optical manufacturing.

  18. Producing high-accuracy lattice models from protein atomic coordinates including side chains.

    Science.gov (United States)

    Mann, Martin; Saunders, Rhodri; Smith, Cameron; Backofen, Rolf; Deane, Charlotte M

    2012-01-01

    Lattice models are a common abstraction used in the study of protein structure, folding, and refinement. They are advantageous because the discretisation of space can make extensive protein evaluations computationally feasible. Various approaches to the protein chain lattice fitting problem have been suggested but only a single backbone-only tool is available currently. We introduce LatFit, a new tool to produce high-accuracy lattice protein models. It generates both backbone-only and backbone-side-chain models in any user defined lattice. LatFit implements a new distance RMSD-optimisation fitting procedure in addition to the known coordinate RMSD method. We tested LatFit's accuracy and speed using a large nonredundant set of high resolution proteins (SCOP database) on three commonly used lattices: 3D cubic, face-centred cubic, and knight's walk. Fitting speed compared favourably to other methods and both backbone-only and backbone-side-chain models show low deviation from the original data (~1.5 Å RMSD in the FCC lattice). To our knowledge this represents the first comprehensive study of lattice quality for on-lattice protein models including side chains while LatFit is the only available tool for such models.

  19. Systems Engineering Provides Successful High Temperature Steam Electrolysis Project

    Energy Technology Data Exchange (ETDEWEB)

    Charles V. Park; Emmanuel Ohene Opare, Jr.

    2011-06-01

    This paper describes two Systems Engineering Studies completed at the Idaho National Laboratory (INL) to support development of the High Temperature Stream Electrolysis (HTSE) process. HTSE produces hydrogen from water using nuclear power and was selected by the Department of Energy (DOE) for integration with the Next Generation Nuclear Plant (NGNP). The first study was a reliability, availability and maintainability (RAM) analysis to identify critical areas for technology development based on available information regarding expected component performance. An HTSE process baseline flowsheet at commercial scale was used as a basis. The NGNP project also established a process and capability to perform future RAM analyses. The analysis identified which components had the greatest impact on HTSE process availability and indicated that the HTSE process could achieve over 90% availability. The second study developed a series of life-cycle cost estimates for the various scale-ups required to demonstrate the HTSE process. Both studies were useful in identifying near- and long-term efforts necessary for successful HTSE process deployment. The size of demonstrations to support scale-up was refined, which is essential to estimate near- and long-term cost and schedule. The life-cycle funding profile, with high-level allocations, was identified as the program transitions from experiment scale R&D to engineering scale demonstration.

  20. Electrolysis Propulsion Provides High-Performance, Inexpensive, Clean Spacecraft Propulsion

    Science.gov (United States)

    deGroot, Wim A.

    1999-01-01

    An electrolysis propulsion system consumes electrical energy to decompose water into hydrogen and oxygen. These gases are stored in separate tanks and used when needed in gaseous bipropellant thrusters for spacecraft propulsion. The propellant and combustion products are clean and nontoxic. As a result, costs associated with testing, handling, and launching can be an order of magnitude lower than for conventional propulsion systems, making electrolysis a cost-effective alternative to state-of-the-art systems. The electrical conversion efficiency is high (>85 percent), and maximum thrust-to-power ratios of 0.2 newtons per kilowatt (N/kW), a 370-sec specific impulse, can be obtained. A further advantage of the water rocket is its dual-mode potential. For relatively high thrust applications, the system can be used as a bipropellant engine. For low thrust levels and/or small impulse bit requirements, cold gas oxygen can be used alone. An added innovation is that the same hardware, with modest modifications, can be converted into an energy-storage and power-generation fuel cell, reducing the spacecraft power and propulsion system weight by an order of magnitude.

  1. A new, highly precise measurement technology for the in vitro evaluation of the accuracy of digital imaging data.

    Science.gov (United States)

    von Wilmowsky, Cornelius; Bergauer, Bastian; Nkenke, Emeka; Neukam, Friedrich Wilhelm; Neuhuber, Winfried; Lell, Michael; Keller, Andrea; Eitner, Stephan; Matta, Ragai-Edward

    2015-10-01

    Three-dimensional radiological imaging data play an increasingly role in planning, simulation, and navigation in oral and maxillofacial surgery. The aim of this study was to establish a new, highly precise, in vitro measurement technology for the evaluation of the geometric accuracy down to the micrometric range of digital imaging data. A macerated human mandible was scanned optically with an industrial, non-contact, white light scanner, and a three-dimensional (3D) model was obtained, which served as a master model. The mandible was then scanned 10 times by cone beam computed tomography (CBCT), and the generated 3D surface bone model was virtually compared with the master model. To evaluate the accuracy of the CBCT scans, the standard deviation and the intraclass coefficient were determined. A total of 19 measurement points in 10 CBCT scans were investigated, and showed an average value of 0.2676 mm with a standard deviation of 0.0593 mm. The standard error of the mean was 0.0043 mm. The intraclass correlation coefficient (ICC) within the 10 CBCT scans was 0.9416. This highly precise measuring technology was demonstrated to be appropriate for the evaluation of the accuracy of digital imaging data, down to the micrometric scale. This method is able to exclude human measurement errors, as the software calculates the superimposition and deviation. Thus inaccuracies caused by measurement errors can be avoided. This method provides a highly precise determination of deviations of different CBCT parameters and 3D models for surgical, navigational, and diagnostic purposes. Thus, surgical procedures and the post-operative outcomes can be precisely simulated to benefit the patient. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Spatial, High-Accuracy, Positioning-Encoding Sensor (SHAPES) for large space system control applications

    Science.gov (United States)

    Mclauchlan, J. M.

    1982-01-01

    The Spatial, High-Accuracy, Position-Encoding Sensor is a controls sensor suitable for the determination of the static shape and vibrational motion of large space structures and similar systems and for the determination of position and velocity in rendezvous and docking. It uses a combination of electro-optical techniques to measure the three-dimensional coordinates distributed over the structure at reading rates high compared to the rates at which the coordinates are changing. The technical approach is that of measuring the distance to and the direction of points on the structure from a single sensor head. Many points can be measured simultaneously from a single head without significantly increasing the complexity of the system.

  3. CMOS highly linear direct-conversion transmitter for WCDMA with fine gain accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Li Xin; Fu Jian; Huang Yumei; Hong Zhiliang, E-mail: yumeihuang@fudan.edu.cn [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2011-08-15

    A highly linear, high output power, 0.13 {mu}m CMOS direct conversion transmitter for wideband code division multiple access (WCDMA) is described. The transmitter delivers 6.8 dBm output power with 38 mA current consumption. With careful design on the resistor bank in the IQ-modulator, the gain step accuracy is within 0.1 dB, hence the image rejection ratio can be kept below -47 dBc for the entire output range. The adjacent channel leakage ratio and the LO leakage at 6.8 dBm output power are -44 dBc - 5 MHz and -37 dBc, respectively, and the corresponding EVM is 3.6%. The overall gain can be programmed in 6 dB steps in a 66-dB range.

  4. CMOS highly linear direct-conversion transmitter for WCDMA with fine gain accuracy

    Science.gov (United States)

    Xin, Li; Jian, Fu; Yumei, Huang; Zhiliang, Hong

    2011-08-01

    A highly linear, high output power, 0.13 μm CMOS direct conversion transmitter for wideband code division multiple access (WCDMA) is described. The transmitter delivers 6.8 dBm output power with 38 mA current consumption. With careful design on the resistor bank in the IQ-modulator, the gain step accuracy is within 0.1 dB, hence the image rejection ratio can be kept below -47 dBc for the entire output range. The adjacent channel leakage ratio and the LO leakage at 6.8 dBm output power are -44 dBc @ 5 MHz and -37 dBc, respectively, and the corresponding EVM is 3.6%. The overall gain can be programmed in 6 dB steps in a 66-dB range.

  5. High Accuracy mass Measurement of the very Short-Lived Halo Nuclide $^{11}$Li

    CERN Multimedia

    Le scornet, G

    2002-01-01

    The archetypal halo nuclide $^{11}$Li has now attracted a wealth of experimental and theoretical attention. The most outstanding property of this nuclide, its extended radius that makes it as big as $^{48}$Ca, is highly dependent on the binding energy of the two neutrons forming the halo. New generation experiments using radioactive beams with elastic proton scattering, knock-out and transfer reactions, together with $\\textit{ab initio}$ calculations require the tightening of the constraint on the binding energy. Good metrology also requires confirmation of the sole existing precision result to guard against a possible systematic deviation (or mistake). We propose a high accuracy mass determintation of $^{11}$Li, a particularly challenging task due to its very short half-life of 8.6 ms, but one perfectly suiting the MISTRAL spectrometer, now commissioned at ISOLDE. We request 15 shifts of beam time.

  6. Appraisal of the realistic accuracy of molecular dynamics of high-pressure hydrogen

    Directory of Open Access Journals (Sweden)

    Graeme J. Ackland

    2015-12-01

    Full Text Available Molecular dynamics (MD is a powerful method for studying the behaviour of materials at high temperature. In practice, however, its effectiveness in representing real systems is limited by the accuracy of the forces, finite size effects, quantization and equilibration methods. In this paper, we report and discuss some calculations carried out using MD on high-pressure hydrogen, reviewing a number of sources of error, of which the neglect of zero-point vibrations is quantitatively the largest. We show that simulations using ab initio MD with the PBE functional predict a large stability field for the molecular Cmca4 structure at pressures just above those achieved in current experiments above the stability range of the mixed molecular layered Phase IV. However, the various errors in the simulation all point towards a much smaller stability range, and the likelihood of a non-molecular phase based on low-coordination networks or chains of atoms.

  7. High accuracy of family history of melanoma in Danish melanoma cases

    DEFF Research Database (Denmark)

    Wadt, Karin A W; Drzewiecki, Krzysztof T; Gerdes, Anne-Marie

    2015-01-01

    The incidence of melanoma in Denmark has immensely increased over the last 10 years making Denmark a high risk country for melanoma. In the last two decades multiple public campaigns have sought to increase the awareness of melanoma. Family history of melanoma is a known major risk factor...... but previous studies have shown that self-reported family history of melanoma is highly inaccurate. These studies are 15 years old and we wanted to examine if a higher awareness of melanoma has increased the accuracy of self-reported family history of melanoma. We examined the family history of 181 melanoma...... probands who reported 199 cases of melanoma in relatives, of which 135 cases where in first degree relatives. We confirmed the diagnosis of melanoma in 77% of all relatives, and in 83% of first degree relatives. In 181 probands we validated the negative family history of melanoma in 748 first degree...

  8. Utility of ionosphere and troposphere models for extending the range of high-accuracy GPS

    Science.gov (United States)

    Dodd, David William

    This dissertation studied the use of NOAA real-time ionosphere and troposphere products in extending the range of long-baseline, high-accuracy DGPS for real-time positioning. The question being addressed by this work is; can existing real-time ionosphere and troposphere models reduce the observation uncertainties to the level where they can be used to reliably resolve integer ambiguities, in real-time, over long baselines (>30km). In-house GPS processing software (USM_OTF) was developed to ingest the models and compute epoch-to-epoch, float and fixed ambiguity position solutions. Single baseline processing, ranging from 20 to 740 kin, over several days in four separate sessions (July 2004, January 2005, August 2005 and July 2006) incorporating four regions of the U.S.A. (Michigan, California, Central and the South East), were evaluated. The first session looked at the NOAA real-time troposphere model and the second session looked at the NOAA real-time ionosphere model. The third and fourth sessions looked at the use of both the NOAA real-time ionosphere and troposphere models. Results showed that the NOAA troposphere model reduced the height bias uncertainty by up to 30 cm, under high activity conditions. They also showed that the troposphere model increased the uncertainty standard deviation under these high activity conditions. The results from the first tests of the real-time NOAA ionosphere model showed that, due to satellite coverage issues, it produced worse results than other real-time models. The NOAA model suffered from lack of satellite coverage corrections, especially in areas near the limits of the model, and at the beginning and end of a satellite's flight path. A reduction in satellite numbers lead to weaker geometry and less reliable position solutions. These tests showed that it was better to provide less accurate ionosphere estimates than to leave the satellites out of the solution. These problems were addressed by NOAA prior to the final tests

  9. EGNSS High Accuracy System Improving Photovoltaic Plant Maintenance using RPAS integrated with Low-cost RTK Receiver

    DEFF Research Database (Denmark)

    Nisi, Marco; Menichetti, Fabio; Bilal, Muhammad

    Global Navigation Satellite System (GNSS) Real Time Kinematic (RTK) is the key enabling technology for a number of applications demanding very high positioning accuracy as their operational requirement. This include, but not limited to, mapping, surveying, robot guidance, and precision agriculture...... to name a few. Typically, GNSS RTK employs high-end dual-frequency receivers and antennas to deliver precise positioning that, in some way, restricts the use of GNSS RTK to a subset of user market due to very high cost. The emerging mass-market user applications, however, require centimeter positioning...... accuracy considering a cost-effective solution. This calls for low-cost GNSS RTK technology to create new possibilities for mass-market user applications to make use of GNSS high accuracy positioning in a variety of ways. One of the applications that make use of low-cost RTK is EGNSS high accuracy system...

  10. Dynamical dark energy simulations: high accuracy power spectra at high redshift

    Energy Technology Data Exchange (ETDEWEB)

    Casarini, Luciano; Bonometto, Silvio A. [Department of Physics G. Occhialini-Milano-Bicocca University, Piazza della Scienza 3, 20126 Milano (Italy); Maccio, Andrea V., E-mail: luciano.casarini@mib.infn.it, E-mail: maccio@mpia.de, E-mail: silvio.bonometto@mib.infn.it [Max-Planck-Institut fuer Astronomie, Koenigstuhl 17, 69117 Heidelberg (Germany)

    2009-03-15

    Accurate predictions on non-linear power spectra, at various redshift z, will be a basic tool to interpret cosmological data from next generation mass probes, so obtaining key information on Dark Energy nature. This calls for high precision simulations, covering the whole functional space of w(z) state equations and taking also into account the admitted ranges of other cosmological parameters; surely a difficult task. A procedure was however suggested, able to match the spectra at z = 0, up to k {approx} 3 hMpc{sup -1}, in cosmologies with an (almost) arbitrary w(z), by making recourse to the results of N-body simulations with w = const. In this paper we extend such procedure to high redshift and test our approach through a series of N-body gravitational simulations of various models, including a model closely fitting WMAP5 and complementary data. Our approach detects w = const. models, whose spectra meet the requirement within 1% at z = 0 and perform even better at higher redshift, where they are close to a permil precision. Available Halofit expressions, extended to (constant) w{ne}-1 are unfortunately unsuitable to fit the spectra of the physical models considered here. Their extension to cover the desired range should be however feasible, and this will enable us to match spectra from any DE state equation.

  11. A method to enhance the measurement accuracy of Raman shift based on high precision calibration technique

    Science.gov (United States)

    Ding, Xiang; Li, Fei; Zhang, Jiyan; Liu, Wenli

    2016-10-01

    Raman spectrometers are usually calibrated periodically to ensure their measurement accuracy of Raman shift. A combination of a piece of monocrystalline silicon chip and a low pressure discharge lamp is proposed as a candidate for the reference standard of Raman shift. A high precision calibration technique is developed to accurately determine the standard value of the silicon's Raman shift around 520cm-1. The technique is described and illustrated by measuring a piece of silicon chip against three atomic spectral lines of a neon lamp. A commercial Raman spectrometer is employed and its error characteristics of Raman shift are investigated. Error sources are evaluated based on theoretical analysis and experiments, including the sample factor, the instrumental factor, the laser factor and random factors. Experimental results show that the expanded uncertainty of the silicon's Raman shift around 520cm-1 can acheive 0.3 cm-1 (k=2), which is more accurate than most of currently used reference materials. The results are validated by comparison measurement between three Raman spectrometers. It is proved that the technique can remarkably enhance the accuracy of Raman shift, making it possible to use the silicon and the lamp to calibrate Raman spectrometers.

  12. Combined Scintigraphy and Tumor Marker Analysis Predicts Unfavorable Histopathology of Neuroblastic Tumors with High Accuracy.

    Directory of Open Access Journals (Sweden)

    Wolfgang Peter Fendler

    Full Text Available Our aim was to improve the prediction of unfavorable histopathology (UH in neuroblastic tumors through combined imaging and biochemical parameters.123I-MIBG SPECT and MRI was performed before surgical resection or biopsy in 47 consecutive pediatric patients with neuroblastic tumor. Semi-quantitative tumor-to-liver count-rate ratio (TLCRR, MRI tumor size and margins, urine catecholamine and NSE blood levels of neuron specific enolase (NSE were recorded. Accuracy of single and combined variables for prediction of UH was tested by ROC analysis with Bonferroni correction.34 of 47 patients had UH based on the International Neuroblastoma Pathology Classification (INPC. TLCRR and serum NSE both predicted UH with moderate accuracy. Optimal cut-off for TLCRR was 2.0, resulting in 68% sensitivity and 100% specificity (AUC-ROC 0.86, p < 0.001. Optimal cut-off for NSE was 25.8 ng/ml, resulting in 74% sensitivity and 85% specificity (AUC-ROC 0.81, p = 0.001. Combination of TLCRR/NSE criteria reduced false negative findings from 11/9 to only five, with improved sensitivity and specificity of 85% (AUC-ROC 0.85, p < 0.001.Strong 123I-MIBG uptake and high serum level of NSE were each predictive of UH. Combined analysis of both parameters improved the prediction of UH in patients with neuroblastic tumor. MRI parameters and urine catecholamine levels did not predict UH.

  13. [Accuracy of correlation function method for evaluating pulsed high intensity focused ultrasound].

    Science.gov (United States)

    Zhao, Xin; Zou, Jianzhong; Wu, Feng; Liu, Fang; Jiao, Jiao

    2013-01-01

    To investigate the accuracy of ultrasound monitoring during pulsed high intensity focused ultrasound (PHIFU) treatment and improve the sensitivity of ultrasound monitoring of tissue necrosis caused by PHIFU treatment. Bovine liver ex vivo was dot-exposed with HIFU at the therapeutic doses of 2000 J (group A) and 1440 J (group B). The two groups were further divided into groups A1 (power 100 W, duty cycle 100%, irradiate 20 s) A2 (power 100 W, duty cycle 50%, irradiate 40 s), A3 (power 100 W, duty cycle 40%, irradiate 50 s), B1 (power 120 W, duty cycle 100%, irradiate 12 s), B2 (power 100 W, duty cycle 50%, irradiate 24 s), and B3 (power 100 W, duty cycle 40%, irradiate 30 s). The gray scale changes in the ultrasonic images after the exposures were observed, and the correlation function of the image was calculated before and after the exposure. The accuracy of evaluations based on the correlation function and gray-scale changes was compared. The correct rate of gray scale-based evaluation of tissue necrosis caused by PHIFU was only 51%, while that by correlation function-based evaluation reached 85%. Monitoring of tissue necrosis caused by PHIFU treatment can not rely solely on evaluation of gray-scale change of the ultrasound images, and the correlation function-based evaluation can be more accurate and sensitive for that purpose.

  14. High Accuracy Mass Measurement of the Dripline Nuclides $^{12,14}$Be

    CERN Multimedia

    2002-01-01

    State-of-the art, three-body nuclear models that describe halo nuclides require the binding energy of the halo neutron(s) as a critical input parameter. In the case of $^{14}$Be, the uncertainty of this quantity is currently far too large (130 keV), inhibiting efforts at detailed theoretical description. A high accuracy, direct mass deterlnination of $^{14}$Be (as well as $^{12}$Be to obtain the two-neutron separation energy) is therefore required. The measurement can be performed with the MISTRAL spectrometer, which is presently the only possible solution due to required accuracy (10 keV) and short half-life (4.5 ms). Having achieved a 5 keV uncertainty for the mass of $^{11}$Li (8.6 ms), MISTRAL has proved the feasibility of such measurements. Since the current ISOLDE production rate of $^{14}$Be is only about 10/s, the installation of a beam cooler is underway in order to improve MISTRAL transmission. The projected improvement of an order of magnitude (in each transverse direction) will make this measureme...

  15. High accuracy of family history of melanoma in Danish melanoma cases.

    Science.gov (United States)

    Wadt, Karin A W; Drzewiecki, Krzysztof T; Gerdes, Anne-Marie

    2015-12-01

    The incidence of melanoma in Denmark has immensely increased over the last 10 years making Denmark a high risk country for melanoma. In the last two decades multiple public campaigns have sought to increase the awareness of melanoma. Family history of melanoma is a known major risk factor but previous studies have shown that self-reported family history of melanoma is highly inaccurate. These studies are 15 years old and we wanted to examine if a higher awareness of melanoma has increased the accuracy of self-reported family history of melanoma. We examined the family history of 181 melanoma probands who reported 199 cases of melanoma in relatives, of which 135 cases where in first degree relatives. We confirmed the diagnosis of melanoma in 77% of all relatives, and in 83% of first degree relatives. In 181 probands we validated the negative family history of melanoma in 748 first degree relatives and found only 1 case of melanoma which was not reported in a 3 case melanoma family. Melanoma patients in Denmark report family history of melanoma in first and second degree relatives with a high level of accuracy with a true positive predictive value between 77 and 87%. In 99% of probands reporting a negative family history of melanoma in first degree relatives this information is correct. In clinical practice we recommend that melanoma diagnosis in relatives should be verified if possible, but even unverified reported melanoma cases in relatives should be included in the indication of genetic testing and assessment of melanoma risk in the family.

  16. High-accuracy calculations of the rotation-vibration spectrum of {{\\rm{H}}}_{3}^{+}

    Science.gov (United States)

    Tennyson, Jonathan; Polyansky, Oleg L.; Zobov, Nikolai F.; Alijah, Alexander; Császár, Attila G.

    2017-12-01

    Calculation of the rotation-vibration spectrum of {{{H}}}3+, as well as of its deuterated isotopologues, with near-spectroscopic accuracy requires the development of sophisticated theoretical models, methods, and codes. The present paper reviews the state-of-the-art in these fields. Computation of rovibrational states on a given potential energy surface (PES) has now become standard for triatomic molecules, at least up to intermediate energies, due to developments achieved by the present authors and others. However, highly accurate Born–Oppenheimer energies leading to highly accurate PESs are not accessible even for this two-electron system using conventional electronic structure procedures (e.g. configuration-interaction or coupled-cluster techniques with extrapolation to the complete (atom-centered Gaussian) basis set limit). For this purpose, highly specialized techniques must be used, e.g. those employing explicitly correlated Gaussians and nonlinear parameter optimizations. It has also become evident that a very dense grid of ab initio points is required to obtain reliable representations of the computed points extending from the minimum to the asymptotic limits. Furthermore, adiabatic, relativistic, and quantum electrodynamic correction terms need to be considered to achieve near-spectroscopic accuracy during calculation of the rotation-vibration spectrum of {{{H}}}3+. The remaining and most intractable problem is then the treatment of the effects of non-adiabatic coupling on the rovibrational energies, which, in the worst cases, may lead to corrections on the order of several cm‑1. A promising way of handling this difficulty is the further development of effective, motion- or even coordinate-dependent, masses and mass surfaces. Finally, the unresolved challenge of how to describe and elucidate the experimental pre-dissociation spectra of {{{H}}}3+ and its isotopologues is discussed.

  17. High-accuracy infra-red thermography method using reflective marker arrays

    Science.gov (United States)

    Kirollos, Benjamin; Povey, Thomas

    2017-09-01

    In this paper, we describe a new method for high-accuracy infra-red (IR) thermography measurements in situations with significant spatial variation in reflected radiation from the surroundings, or significant spatial variation in surface emissivity due to viewing angle non-uniformity across the field of view. The method employs a reflective marker array (RMA) on the target surface—typically, high emissivity circular dots—and an integrated image analysis algorithm designed to require minimal human input. The new technique has two particular advantages which make it suited to high-accuracy measurements in demanding environments: (i) it allows the reflected radiation component to be calculated directly, in situ, and as a function of position, overcoming a key problem in measurement environments with non-uniform and unsteady stray radiation from the surroundings; (ii) using image analysis of the marker array (via apparent aspect ratio of the circular reflective markers), the local viewing angle of the target surface can be estimated, allowing corrections for angular variation of local emissivity to be performed without prior knowledge of the geometry. A third advantage of the technique is that allows for simple focus-stacking algorithms due to increased image entropy. The reflective marker array method is demonstrated for an isothermal, hemispherical object exposed to an external IR source arranged to give a significant non-uniform reflected radiation term. This is an example of a challenging environment, both because of the significant non-uniform reflected radiation term, and also the significant variation in target emissivity due to surface angle variation. We demonstrate that the new RMA IR technique leads to significantly lower error in evaluated surface temperature than conventional IR techniques. The method is applicable to any complex radiative environment.

  18. Analysis of the plasmodium falciparum proteome by high-accuracy mass spectrometry

    DEFF Research Database (Denmark)

    Lasonder, Edwin; Ishihama, Yasushi; Andersen, Jens S

    2002-01-01

    -accuracy (average deviation less than 0.02 Da at 1,000 Da) mass spectrometric proteome analysis of selected stages of the human malaria parasite Plasmodium falciparum. The analysis revealed 1,289 proteins of which 714 proteins were identified in asexual blood stages, 931 in gametocytes and 645 in gametes. The last...... two groups provide insights into the biology of the sexual stages of the parasite, and include conserved, stage-specific, secreted and membrane-associated proteins. A subset of these proteins contain domains that indicate a role in cell-cell interactions, and therefore can be evaluated as potential...... components of a malaria vaccine formulation. We also report a set of peptides with significant matches in the parasite genome but not in the protein set predicted by computational methods....

  19. High accuracy Primary Reference gas Mixtures for high-impact greenhouse gases

    Science.gov (United States)

    Nieuwenkamp, Gerard; Zalewska, Ewelina; Pearce-Hill, Ruth; Brewer, Paul; Resner, Kate; Mace, Tatiana; Tarhan, Tanil; Zellweger, Christophe; Mohn, Joachim

    2017-04-01

    Climate change, due to increased man-made emissions of greenhouse gases, poses one of the greatest risks to society worldwide. High-impact greenhouse gases (CO2, CH4 and N2O) and indirect drivers for global warming (e.g. CO) are measured by the global monitoring stations for greenhouse gases, operated and organized by the World Meteorological Organization (WMO). Reference gases for the calibration of analyzers have to meet very challenging low level of measurement uncertainty to comply with the Data Quality Objectives (DQOs) set by the WMO. Within the framework of the European Metrology Research Programme (EMRP), a project to improve the metrology for high-impact greenhouse gases was granted (HIGHGAS, June 2014-May 2017). As a result of the HIGHGAS project, primary reference gas mixtures in cylinders for ambient levels of CO2, CH4, N2O and CO in air have been prepared with unprecedented low uncertainties, typically 3-10 times lower than usually previously achieved by the NMIs. To accomplish these low uncertainties in the reference standards, a number of preparation and analysis steps have been studied and improved. The purity analysis of the parent gases had to be performed with lower detection limits than previously achievable. E.g., to achieve an uncertainty of 2•10-9 mol/mol (absolute) on the amount fraction for N2O, the detection limit for the N2O analysis in the parent gases has to be in the sub nmol/mol domain. Results of an OPO-CRDS analyzer set-up in the 5µm wavelength domain, with a 200•10-12 mol/mol detection limit for N2O, will be presented. The adsorption effects of greenhouse gas components at cylinder surfaces are critical, and have been studied for different cylinder passivation techniques. Results of a two-year stability study will be presented. The fit-for-purpose of the reference materials was studied for possible variation on isotopic composition between the reference material and the sample. Measurement results for a suit of CO2 in air

  20. High-Accuracy Approximation of High-Rank Derivatives: Isotropic Finite Differences Based on Lattice-Boltzmann Stencils

    Directory of Open Access Journals (Sweden)

    Keijo Kalervo Mattila

    2014-01-01

    Full Text Available We propose isotropic finite differences for high-accuracy approximation of high-rank derivatives. These finite differences are based on direct application of lattice-Boltzmann stencils. The presented finite-difference expressions are valid in any dimension, particularly in two and three dimensions, and any lattice-Boltzmann stencil isotropic enough can be utilized. A theoretical basis for the proposed utilization of lattice-Boltzmann stencils in the approximation of high-rank derivatives is established. In particular, the isotropy and accuracy properties of the proposed approximations are derived directly from this basis. Furthermore, in this formal development, we extend the theory of Hermite polynomial tensors in the case of discrete spaces and present expressions for the discrete inner products between monomials and Hermite polynomial tensors. In addition, we prove an equivalency between two approaches for constructing lattice-Boltzmann stencils. For the numerical verification of the presented finite differences, we introduce 5th-, 6th-, and 8th-order two-dimensional lattice-Boltzmann stencils.

  1. High-accuracy approximation of high-rank derivatives: isotropic finite differences based on lattice-Boltzmann stencils.

    Science.gov (United States)

    Mattila, Keijo Kalervo; Hegele Júnior, Luiz Adolfo; Philippi, Paulo Cesar

    2014-01-01

    We propose isotropic finite differences for high-accuracy approximation of high-rank derivatives. These finite differences are based on direct application of lattice-Boltzmann stencils. The presented finite-difference expressions are valid in any dimension, particularly in two and three dimensions, and any lattice-Boltzmann stencil isotropic enough can be utilized. A theoretical basis for the proposed utilization of lattice-Boltzmann stencils in the approximation of high-rank derivatives is established. In particular, the isotropy and accuracy properties of the proposed approximations are derived directly from this basis. Furthermore, in this formal development, we extend the theory of Hermite polynomial tensors in the case of discrete spaces and present expressions for the discrete inner products between monomials and Hermite polynomial tensors. In addition, we prove an equivalency between two approaches for constructing lattice-Boltzmann stencils. For the numerical verification of the presented finite differences, we introduce 5th-, 6th-, and 8th-order two-dimensional lattice-Boltzmann stencils.

  2. High-accuracy biodistribution analysis of adeno-associated virus variants by double barcode sequencing.

    Science.gov (United States)

    Marsic, Damien; Méndez-Gómez, Héctor R; Zolotukhin, Sergei

    2015-01-01

    Biodistribution analysis is a key step in the evaluation of adeno-associated virus (AAV) capsid variants, whether natural isolates or produced by rational design or directed evolution. Indeed, when screening candidate vectors, accurate knowledge about which tissues are infected and how efficiently is essential. We describe the design, validation, and application of a new vector, pTR-UF50-BC, encoding a bioluminescent protein, a fluorescent protein and a DNA barcode, which can be used to visualize localization of transduction at the organism, organ, tissue, or cellular levels. In addition, by linking capsid variants to different barcoded versions of the vector and amplifying the barcode region from various tissue samples using barcoded primers, biodistribution of viral genomes can be analyzed with high accuracy and efficiency.

  3. High-accuracy biodistribution analysis of adeno-associated virus variants by double barcode sequencing

    Directory of Open Access Journals (Sweden)

    Damien Marsic

    2015-01-01

    Full Text Available Biodistribution analysis is a key step in the evaluation of adeno-associated virus (AAV capsid variants, whether natural isolates or produced by rational design or directed evolution. Indeed, when screening candidate vectors, accurate knowledge about which tissues are infected and how efficiently is essential. We describe the design, validation, and application of a new vector, pTR-UF50-BC, encoding a bioluminescent protein, a fluorescent protein and a DNA barcode, which can be used to visualize localization of transduction at the organism, organ, tissue, or cellular levels. In addition, by linking capsid variants to different barcoded versions of the vector and amplifying the barcode region from various tissue samples using barcoded primers, biodistribution of viral genomes can be analyzed with high accuracy and efficiency.

  4. [Urban land use change detection based on high accuracy classification of multispectral remote sensing imagery].

    Science.gov (United States)

    Tong, Xiao-Hua; Zhang, Xue; Liu, Miao-Long

    2009-08-01

    In the present paper, the urban land change in Jiading district of Shanghai was studied on the basis of high accuracy classification for 4 epochs of multispectral remotely sensed imageries. A further improved genetic-algorithm optimized back propagation neural network approach was first employed in our study to obtain sorts of land cover types from the remotely sensed imageries. The urban land and non-urban land types were thus extracted based on the classification result. According to the 16 corresponding relationships between the pixel values in the four urban land imageries and the ones in the generated urban land change imagery, the amount of each type pixel in the generated imagery was calculated according to the four plates, and the situation of urban land change was analyzed and investigated for the study area in three year intervals. The urban development in the study area was also preliminarily revealed.

  5. Computer-aided diagnosis of breast MRI with high accuracy optical flow estimation

    Science.gov (United States)

    Meyer-Baese, Anke; Barbu, Adrian; Lobbes, Marc; Hoffmann, Sebastian; Burgeth, Bernhard; Kleefeld, Andreas; Meyer-Bäse, Uwe

    2015-05-01

    Non-mass enhancing lesions represent a challenge for the radiological reading. They are not well-defined in both morphology (geometric shape) and kinetics (temporal enhancement) and pose a problem to lesion detection and classification. To enhance the discriminative properties of an automated radiological workflow, the correct preprocessing steps need to be taken. In an usual computer-aided diagnosis (CAD) system, motion compensation plays an important role. To this end, we employ a new high accuracy optical flow based motion compensation algorithm with robustification variants. An automated computer-aided diagnosis system evaluates the atypical behavior of these lesions, and additionally considers the impact of non-rigid motion compensation on a correct diagnosis.

  6. High-accuracy extrapolated ab initio thermochemistry of the vinyl, allyl, and vinoxy radicals.

    Science.gov (United States)

    Tabor, Daniel P; Harding, Michael E; Ichino, Takatoshi; Stanton, John F

    2012-07-26

    Enthalpies of formation at both 0 and 298 K were calculated according to the HEAT (High-accuracy Extrapolated Ab initio Thermochemistry) protocol for the title molecules, all of which play important roles in combustion chemistry. At the HEAT345-(Q) level of theory, recommended enthalpies of formation at 0 K are 301.5 ± 1.3, 180.3 ± 1.8, and 23.4 ± 1.5 kJ mol(-1) for vinyl, allyl, and vinoxy, respectively. At 298 K, the corresponding values are 297.3, 168.6, and 16.1 kJ mol(-1), with the same uncertainties. The calculated values for the three radicals are in excellent agreement with the corresponding experimental values, but the uncertainties associated with the HEAT values for vinoxy are considerably smaller than those based on experimental studies.

  7. A new device for liver cancer biomarker detection with high accuracy

    Directory of Open Access Journals (Sweden)

    Shuaipeng Wang

    2015-06-01

    Full Text Available A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus adsorption of the cancer biomarker is localized in the micro-cavity, and the adsorption-induced k variation can be dramatically reduced with comparison to that caused by adsorption of the whole lever. The cantilever is pizeoelectrically driven into vibration which is pizeoresistively sensed by Wheatstone bridge. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and small volume. In addition, an analytical model has been established to eliminate the effect of adsorption-induced lever stiffness change and has been applied to precise mass detection of cancer biomarker AFP, the detected AFP antigen mass (7.6 pg/ml is quite close to the calculated one (5.5 pg/ml, two orders of magnitude better than the value by the fully antibody-immobilized cantilever sensor. These approaches will promote real application of the cantilever sensors in early diagnosis of cancer.

  8. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Jun Qi

    2017-11-01

    Full Text Available This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS. The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF module, which is only used for time synchronization between different nodes, with accuracy up to 1 μs. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM. The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS signal.

  9. High accuracy electromagnetic field solvers for cylindrical waveguides and axisymmetric structures using the finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Eric Michael [Stanford Univ., CA (United States)

    1993-12-01

    Some two-dimensional finite element electromagnetic field solvers are described and tested. For TE and TM modes in homogeneous cylindrical waveguides and monopole modes in homogeneous axisymmetric structures, the solvers find approximate solutions to a weak formulation of the wave equation. Second-order isoparametric lagrangian triangular elements represent the field. For multipole modes in axisymmetric structures, the solver finds approximate solutions to a weak form of the curl-curl formulation of Maxwell`s equations. Second-order triangular edge elements represent the radial (ρ) and axial (z) components of the field, while a second-order lagrangian basis represents the azimuthal (Φ) component of the field weighted by the radius ρ. A reduced set of basis functions is employed for elements touching the axis. With this basis the spurious modes of the curl-curl formulation have zero frequency, so spurious modes are easily distinguished from non-static physical modes. Tests on an annular ring, a pillbox and a sphere indicate the solutions converge rapidly as the mesh is refined. Computed eigenvalues with relative errors of less than a few parts per million are obtained. Boundary conditions for symmetric, periodic and symmetric-periodic structures are discussed and included in the field solver. Boundary conditions for structures with inversion symmetry are also discussed. Special corner elements are described and employed to improve the accuracy of cylindrical waveguide and monopole modes with singular fields at sharp corners. The field solver is applied to three problems: (1) cross-field amplifier slow-wave circuits, (2) a detuned disk-loaded waveguide linear accelerator structure and (3) a 90° overmoded waveguide bend. The detuned accelerator structure is a critical application of this high accuracy field solver. To maintain low long-range wakefields, tight design and manufacturing tolerances are required.

  10. High-accuracy optical extensometer based on coordinate transform in two-dimensional digital image correlation

    Science.gov (United States)

    Lv, Zeqian; Xu, Xiaohai; Yan, Tianhao; Cai, Yulong; Su, Yong; Zhang, Qingchuan

    2018-01-01

    In the measurement of plate specimens, traditional two-dimensional (2D) digital image correlation (DIC) is challenged by two aspects: (1) the slant optical axis (misalignment of the optical camera axis and the object surface) and (2) out-of-plane motions (including translations and rotations) of the specimens. There are measurement errors in the results measured by 2D DIC, especially when the out-of-plane motions are big enough. To solve this problem, a novel compensation method has been proposed to correct the unsatisfactory results. The proposed compensation method consists of three main parts: 1) a pre-calibration step is used to determine the intrinsic parameters and lens distortions; 2) a compensation panel (a rigid panel with several markers located at known positions) is mounted to the specimen to track the specimen's motion so that the relative coordinate transformation between the compensation panel and the 2D DIC setup can be calculated using the coordinate transform algorithm; 3) three-dimensional world coordinates of measuring points on the specimen can be reconstructed via the coordinate transform algorithm and used to calculate deformations. Simulations have been carried out to validate the proposed compensation method. Results come out that when the extensometer length is 400 pixels, the strain accuracy reaches 10 με no matter out-of-plane translations (less than 1/200 of the object distance) nor out-of-plane rotations (rotation angle less than 5°) occur. The proposed compensation method leads to good results even when the out-of-plane translation reaches several percents of the object distance or the out-of-plane rotation angle reaches tens of degrees. The proposed compensation method has been applied in tensile experiments to obtain high-accuracy results as well.

  11. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network.

    Science.gov (United States)

    Qi, Jun; Liu, Guo-Ping

    2017-11-06

    This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS). The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN) node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF) module, which is only used for time synchronization between different nodes, with accuracy up to 1 μ s. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF) for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM). The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS) signal.

  12. Model Accuracy Comparison for High Resolution Insar Coherence Statistics Over Urban Areas

    Science.gov (United States)

    Zhang, Yue; Fu, Kun; Sun, Xian; Xu, Guangluan; Wang, Hongqi

    2016-06-01

    The interferometric coherence map derived from the cross-correlation of two complex registered synthetic aperture radar (SAR) images is the reflection of imaged targets. In many applications, it can act as an independent information source, or give additional information complementary to the intensity image. Specially, the statistical properties of the coherence are of great importance in land cover classification, segmentation and change detection. However, compared to the amount of work on the statistical characters of SAR intensity, there are quite fewer researches on interferometric SAR (InSAR) coherence statistics. And to our knowledge, all of the existing work that focuses on InSAR coherence statistics, models the coherence with Gaussian distribution with no discrimination on data resolutions or scene types. But the properties of coherence may be different for different data resolutions and scene types. In this paper, we investigate on the coherence statistics for high resolution data over urban areas, by making a comparison of the accuracy of several typical statistical models. Four typical land classes including buildings, trees, shadow and roads are selected as the representatives of urban areas. Firstly, several regions are selected from the coherence map manually and labelled with their corresponding classes respectively. Then we try to model the statistics of the pixel coherence for each type of region, with different models including Gaussian, Rayleigh, Weibull, Beta and Nakagami. Finally, we evaluate the model accuracy for each type of region. The experiments on TanDEM-X data show that the Beta model has a better performance than other distributions.

  13. A new TEC interpolation method based on the least squares collocation for high accuracy regional ionospheric maps

    Science.gov (United States)

    Krypiak-Gregorczyk, Anna; Wielgosz, Paweł; Jarmołowski, Wojciech

    2017-04-01

    The ionosphere plays a crucial role in space weather that affects satellite navigation as the ionospheric delay is one of the major errors in GNSS. On the other hand, GNSS observations are widely used to determine the amount of ionospheric total electron content (TEC). An important aspect in the electron content estimation at regional and global scale is adopting the appropriate interpolation strategy. In this paper we propose and validate a new method for regional TEC modeling based on least squares collocation (LSC) with noise variance estimation. This method allows for providing accurate TEC maps with high spatial and temporal resolution. Such maps may be used to support precise GNSS positioning and navigation, e.g. in RTK mode and also in the ionosphere studies. To test applicability of new TEC maps to positioning, double-difference ionospheric corrections were derived from the maps and their accuracy was analyzed. In addition, the corrections were applied to GNSS positioning and validated in ambiguity resolution domain. The tests were carried out during a strong ionospheric storm when the ionosphere is particularly difficult to model. The performance of the new approach was compared to IGS and UPC global, and CODE regional TEC maps. The results showed an advantage of our solution with resulting accuracy of the relative ionospheric corrections usually better than 10 cm, even during the ionospheric disturbances. This proves suitability of our regional TEC maps for, e.g. supporting fast ambiguity resolution in kinematic GNSS positioning.

  14. High-resolution CT of nontuberculous mycobacterium infection in adult CF patients: diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    McEvoy, Sinead; Lavelle, Lisa; Kilcoyne, Aoife; McCarthy, Colin; Dodd, Jonathan D. [St. Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); DeJong, Pim A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Loeve, Martine; Tiddens, Harm A.W.M. [Erasmus MC-Sophia Children' s Hospital, Department of Radiology, Department of Pediatric Pulmonology and Allergology, Rotterdam (Netherlands); McKone, Edward; Gallagher, Charles G. [St. Vincent' s University Hospital, Department of Respiratory Medicine and National Referral Centre for Adult Cystic Fibrosis, Dublin (Ireland)

    2012-12-15

    To determine the diagnostic accuracy of high-resolution computed tomography (HRCT) for the detection of nontuberculous mycobacterium infection (NTM) in adult cystic fibrosis (CF) patients. Twenty-seven CF patients with sputum-culture-proven NTM (NTM+) underwent HRCT. An age, gender and spirometrically matched group of 27 CF patients without NTM (NTM-) was included as controls. Images were randomly and blindly analysed by two readers in consensus and scored using a modified Bhalla scoring system. Significant differences were seen between NTM (+) and NTM (-) patients in the severity of the bronchiectasis subscore [45 % (1.8/4) vs. 35 % (1.4/4), P = 0.029], collapse/consolidation subscore [33 % (1.3/3) vs. 15 % (0.6/3)], tree-in-bud/centrilobular nodules subscore [43 % (1.7/3) vs. 25 % (1.0/3), P = 0.002] and the total CT score [56 % (18.4/33) vs. 46 % (15.2/33), P = 0.002]. Binary logistic regression revealed BMI, peribronchial thickening, collapse/consolidation and tree-in-bud/centrilobular nodules to be predictors of NTM status (R{sup 2} = 0.43). Receiver-operator curve analysis of the regression model showed an area under the curve of 0.89, P < 0.0001. In adults with CF, seven or more bronchopulmonary segments showing tree-in-bud/centrilobular nodules on HRCT is highly suggestive of NTM colonisation. (orig.)

  15. Rigorous Training of Dogs Leads to High Accuracy in Human Scent Matching-To-Sample Performance.

    Directory of Open Access Journals (Sweden)

    Sophie Marchal

    Full Text Available Human scent identification is based on a matching-to-sample task in which trained dogs are required to compare a scent sample collected from an object found at a crime scene to that of a suspect. Based on dogs' greater olfactory ability to detect and process odours, this method has been used in forensic investigations to identify the odour of a suspect at a crime scene. The excellent reliability and reproducibility of the method largely depend on rigor in dog training. The present study describes the various steps of training that lead to high sensitivity scores, with dogs matching samples with 90% efficiency when the complexity of the scents presented during the task in the sample is similar to that presented in the in lineups, and specificity reaching a ceiling, with no false alarms in human scent matching-to-sample tasks. This high level of accuracy ensures reliable results in judicial human scent identification tests. Also, our data should convince law enforcement authorities to use these results as official forensic evidence when dogs are trained appropriately.

  16. Ultrastable low-noise current amplifier: a novel device for measuring small electric currents with high accuracy.

    Science.gov (United States)

    Drung, D; Krause, C; Becker, U; Scherer, H; Ahlers, F J

    2015-02-01

    An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

  17. Accuracy of the field triage protocol in selecting severely injured patients after high energy trauma.

    Science.gov (United States)

    van Laarhoven, J J E M; Lansink, K W W; van Heijl, M; Lichtveld, R A; Leenen, L P H

    2014-05-01

    For optimal treatment of trauma patients it is of great importance to identify patients who are at risk for severe injuries. The Dutch field triage protocol for trauma patients, the LPA (National Protocol of Ambulance Services), is designed to get the right patient, in the right time, to the right hospital. Purpose of this study was to determine diagnostic accuracy and compliance of this triage protocol. Triage criteria were categorised into physiological condition (P), mechanism of trauma (M) and injury type (I). A retrospective analysis of prospectively collected data of all high-energy trauma patients from 2008 to 2011 in the region Central Netherlands is performed. Diagnostic parameters (sensitivity, specificity, negative predictive value, positive predictive value) of the field triage protocol for selecting severely injured patients were calculated including rates of under- and overtriage. Undertriage was defined as the proportion of severely injured patients (Injury Severity Score (ISS)≥16) who were transported to a level two or three trauma care centre. Overtriage was defined as the proportion of non-severely injured patients (ISS<16) who were transported to a level one trauma care centre. Overall sensitivity and specificity of the field triage protocol was 89.1% (95% confidence interval (CI) 84.4-92.6) and 60.5% (95% CI 57.9-63.1), respectively. The overall rate of undertriage was 10.9% (95%CI 7.4-15.7) and the overall rate of overtriage was 39.5% (95%CI 36.9-42.1). These rates were 16.5% and 37.7%, respectively for patients with M+I-P-. Compliance to the triage protocol for patients with M+I-P- was 78.7%. Furthermore, compliance in patients with either a positive I+ or positive P+ was 91.2%. The overall rate of undertriage (10.8%) was mainly influenced by a high rate of undertriage in the group of patients with only a positive mechanism criterion, therefore showing low diagnostic accuracy in selecting severely injured patients. As a consequence these

  18. Design of high-accuracy two-axis sun-tracking system based on optical fiber

    Science.gov (United States)

    Li, Dan; Zhou, Wang; Li, Ye

    2011-08-01

    This paper mainly introduces the system of sun-tracking control in CPV (Concentrating Photovoltaic), includes new structure design, process circuit and software design. This system includes five photoelectric sensors, five optical fibers, one microcontroller, two-axis motion mechanism and motors etc. Here a center fiber is used to determine whether the sun appears and get a reference illuminance, and other four fibers are symmetrically distributed around the center fiber. The optical fibers lead sunlight energy into photoelectric sensors and their length can be adjusted according to actual case. So that system is flexible and has good anti-jamming. The difference value of optical energy gained by each pair of opposite optical fiber is important measure data processed by MCU. Through the calculate result by a MCU, the system can gain the direction of the sun in real time. In addition, this paper presents processing circuit, software about control process as well as error analyzes. The software also provides a scheme for suiting any weather. This new structure can protect the photoelectric sensor in any case of the weather and environment, because the sensors are deeply put inside the instrument and the light energy is passed by the fibers. More than that, through calculating the difference value of each opposite pair of fiber, controlling the motors and increasing the accuracy of sun-tracking can be realized.

  19. Demonstrating High-Accuracy Orbital Access Using Open-Source Tools

    Science.gov (United States)

    Gilbertson, Christian; Welch, Bryan

    2017-01-01

    Orbit propagation is fundamental to almost every space-based analysis. Currently, many system analysts use commercial software to predict the future positions of orbiting satellites. This is one of many capabilities that can replicated, with great accuracy, without using expensive, proprietary software. NASAs SCaN (Space Communication and Navigation) Center for Engineering, Networks, Integration, and Communications (SCENIC) project plans to provide its analysis capabilities using a combination of internal and open-source software, allowing for a much greater measure of customization and flexibility, while reducing recurring software license costs. MATLAB and the open-source Orbit Determination Toolbox created by Goddard Space Flight Center (GSFC) were utilized to develop tools with the capability to propagate orbits, perform line-of-sight (LOS) availability analyses, and visualize the results. The developed programs are modular and can be applied for mission planning and viability analysis in a variety of Solar System applications. The tools can perform 2 and N-body orbit propagation, find inter-satellite and satellite to ground station LOS access (accounting for intermediate oblate spheroid body blocking, geometric restrictions of the antenna field-of-view (FOV), and relativistic corrections), and create animations of planetary movement, satellite orbits, and LOS accesses. The code is the basis for SCENICs broad analysis capabilities including dynamic link analysis, dilution-of-precision navigation analysis, and orbital availability calculations.

  20. Raman spectroscopic determination of the molecular constants of the hydrogen isotopologues with high accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Krasch, Bennet; Mirz, Sebastian; Groessle, Robin [Karlsruhe Institute of Technology KIT (Germany). Institute for Technical Physics (ITEP), Tritium Laboratory Karlsruhe (TLK); Collaboration: KATRIN-Collaboration

    2016-07-01

    The interest in the thermodynamic properties of gases as the chemical equilibrium is faced by the challenge of time-consuming and technical extensive experimental setups. One possible solution is the derivation of these properties from the molecular constants. The rotational and vibrational movement of diatomic molecules, as the hydrogen isotopologues, is described by the concept of the rotational anharmonic oscillator. The molecular constants are the free parameters of this concept. Molecular constants themselves can be determined by measuring the line position of rotational and/or rotational transitions e.g. with Raman spectroscopy for hydrogen as it has been done since several years. In this contribution a Raman method was development to measure the molecular constant of the hydrogen isotopologues with high accuracy to obtain reliable results. But not only the method was development but also a complete measurement uncertainty budget was set up. The uncertainty budget contains all possible sources for uncertainties from the measurement period or the analysis process as well the contribution of each single uncertainty. The method and the uncertainty budget were exemplary tested on Deuterium.

  1. High Accuracy Ground-based near-Earth-asteroid Astrometry using Synthetic Tracking

    Science.gov (United States)

    Zhai, Chengxing; Shao, Michael; Saini, Navtej; Sandhu, Jagmit; Werne, Thomas; Choi, Philip; Ely, Todd A.; Jacobs, Chirstopher S.; Lazio, Joseph; Martin-Mur, Tomas J.; Owen, William M.; Preston, Robert; Turyshev, Slava; Michell, Adam; Nazli, Kutay; Cui, Isaac; Monchama, Rachel

    2018-01-01

    Accurate astrometry is crucial for determining the orbits of near-Earth-asteroids (NEAs). Further, the future of deep space high data rate communications is likely to be optical communications, such as the Deep Space Optical Communications package that is part of the baseline payload for the planned Psyche Discovery mission to the Psyche asteroid. We have recently upgraded our instrument on the Pomona College 1 m telescope, at JPL's Table Mountain Facility, for conducting synthetic tracking by taking many short exposure images. These images can be then combined in post-processing to track both asteroid and reference stars to yield accurate astrometry. Utilizing the precision of the current and future Gaia data releases, the JPL-Pomona College effort is now demonstrating precision astrometry on NEAs, which is likely to be of considerable value for cataloging NEAs. Further, treating NEAs as proxies of future spacecraft that carry optical communication lasers, our results serve as a measure of the astrometric accuracy that could be achieved for future plane-of-sky optical navigation.

  2. Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer

    Directory of Open Access Journals (Sweden)

    Akifumi Takanabe

    2017-02-01

    Full Text Available A fast, high-accuracy universal polarimeter was developed using a charge-coupled device (CCD spectrometer (CCD-HAUP, to carry out simultaneous optical anisotropic (linear birefringence, LB; linear dichroism, LD and chiroptical (circular birefringence, CB; circular dichroism, CD measurements on single crystals without any pretreatment, in the visible region between 400–680 nm. The principle of the HAUP method is to measure the intensities of emergent light passing through a polarizer, a crystal sample, and then an analyzer, as the azimuth angles of the polarizer and analyzer are independently altered. The CCD-HAUP has the unique feature that white transmitted light intensity can be measured using a CCD spectrometer, compared with the generalized HAUP (G-HAUP system in which monochromatic transmitted light is measured using a photomultiplier. The CCD-HAUP measurements across the entire wavelength region are completed within the G-HAUP measurement time for a single wavelength. The CCD-HAUP drastically reduces the measurement time for a dataset to only 1.5 h, from the 24 h required for the G-HAUP system. LB, LD, CB, and CD measurements of single crystals of α-quartz and enantiomeric photomechanical salicylidenephenylethylamines before, during, and after ultraviolet light irradiation show results comparable to those obtained using the G-HAUP system. The newly developed system is very effective for samples susceptible to degradation induced by external stimuli, such as light and heat.

  3. High-accuracy measurement of low-water-content in liquid using NIR spectral absorption method

    Science.gov (United States)

    Peng, Bao-Jin; Wan, Xu; Jin, Hong-Zhen; Zhao, Yong; Mao, He-Fa

    2005-01-01

    Water content measurement technologies are very important for quality inspection of food, medicine products, chemical products and many other industry fields. In recent years, requests for accurate low-water-content measurement in liquid are more and more exigent, and great interests have been shown from the research and experimental work. With the development and advancement of modern production and control technologies, more accurate water content technology is needed. In this paper, a novel experimental setup based on near-infrared (NIR) spectral technology and fiber-optic sensor (OFS) is presented. It has a good measurement accuracy about -/+ 0.01%, which is better, to our knowledge, than most other methods published until now. It has a high measurement resolution of 0.001% in the measurement range from zero to 0.05% for water-in-alcohol measurement, and the water-in-oil measurement is carried out as well. In addition, the advantages of this method also include pollution-free to the measured liquid, fast measurement and so on.

  4. A 3-D high accuracy positioning system based on visible light communication with novel positioning algorithm

    Science.gov (United States)

    Zheng, Huanhuan; Xu, Zhaowen; Yu, Changyuan; Gurusamy, Mohan

    2017-08-01

    A novel indoor positioning system (IPS) with high positioning precision, based on visible light communication (VLC), is proposed and demonstrated with the dimensions of 100 cm×118.5 cm×128.7 cm. The average positioning distance error is 1.72 cm using the original 2-D positioning algorithm. However, at the corners of the test-bed, the positioning errors are relatively larger than other places. Thus, an error correcting algorithm (ECA) is applied at the corners in order to improve the positioning accuracy. The average positioning errors of four corners decrease from 3.67 cm to 1.55 cm. Then, a 3-D positioning algorithm is developed and the average positioning error of 1.90 cm in space is achieved. Four altitude levels are chosen and on each receiver plane with different heights, four points are picked up to test the positioning error. The average positioning errors in 3-D space are all within 3 cm on these four levels and the performance on each level is similar. A random track is also drawn to show that in 3-D space, the positioning error of random point is within 3 cm.

  5. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

    Directory of Open Access Journals (Sweden)

    Yichi Zhang

    2016-01-01

    Full Text Available Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL power calculation formulas for eyes with an axial length (AL greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II using User Group for Laser Interference Biometry (ULIB constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.. Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice.

  6. GRACE Data-based High Accuracy Global Static Earth's Gravity Field Model

    Directory of Open Access Journals (Sweden)

    CHEN Qiujie

    2016-04-01

    Full Text Available To recover the highly accurate static earth's gravity field by using GRACE satellite data is one of the hot topics in geodesy. Since linearization errors of dynamic approach quickly increase when extending satellite arc length, we established a modified dynamic approach for processing GRACE orbit and range-rate measurements in this paper, which treated orbit observations of the twin GRACE satellites as approximate values for linearization. Using the GRACE data spanning the period Jan. 2003 to Dec. 2010, containing satellite attitudes, orbits, range-rate, and non-conservative forces, we developed two global static gravity field models. One is the unconstrained solution called Tongji-Dyn01s complete to degree and order 180; the other one is the Tongji-Dyn01k model computed by using Kaula constraint. The comparisons between our models and those latest GRACE-only models (including the AIUB-GRACE03, the GGM05S, the ITSG-Grace2014k and the Tongji-GRACE01 published by different international groups, and the external validations with marine gravity anomalies from DTU13 product and height anomalies from GPS/levelling data, were performed in this study. The results demonstrate that the Tongji-Dyn01s has the same accuracy level with those of the latest GRACE-only models, while the Tongji-Dyn01k model is closer to the EIGEN6C2 than the other GRACE-only models as a whole.

  7. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.

    Science.gov (United States)

    Kaufmann, S; Malhotra, A; Ardelt, G; Ryschka, M

    2014-06-01

    Bioimpedance measurements are useful tools in biomedical engineering and life science. Bioimpedance is the electrical impedance of living tissue and can be used in the analysis of various physiological parameters. Bioimpedance is commonly measured by injecting a small well known alternating current via surface electrodes into an object under test and measuring the resultant surface voltages. It is non-invasive, painless and has no known hazards. This work presents a field programmable gate array based high accuracy broadband bioimpedance measurement system for time resolved bioimpedance measurements. The system is able to measure magnitude and phase of complex impedances under test in a frequency range of about 10-500 kHz with excitation currents from 10 µA to 5 mA. The overall measurement uncertainties stay below 1% for the impedance magnitude and below 0.5° for the phase in most measurement ranges. Furthermore, the described system has a sample rate of up to 3840 impedance spectra per second. The performance of the bioimpedance measurement system is demonstrated with a resistor based system calibration and with measurements on biological samples.

  8. Statistical downscaling of precipitation using local regression and high accuracy surface modeling method

    Science.gov (United States)

    Zhao, Na; Yue, Tianxiang; Zhou, Xun; Zhao, Mingwei; Liu, Yu; Du, Zhengping; Zhang, Lili

    2017-07-01

    Downscaling precipitation is required in local scale climate impact studies. In this paper, a statistical downscaling scheme was presented with a combination of geographically weighted regression (GWR) model and a recently developed method, high accuracy surface modeling method (HASM). This proposed method was compared with another downscaling method using the Coupled Model Intercomparison Project Phase 5 (CMIP5) database and ground-based data from 732 stations across China for the period 1976-2005. The residual which was produced by GWR was modified by comparing different interpolators including HASM, Kriging, inverse distance weighted method (IDW), and Spline. The spatial downscaling from 1° to 1-km grids for period 1976-2005 and future scenarios was achieved by using the proposed downscaling method. The prediction accuracy was assessed at two separate validation sites throughout China and Jiangxi Province on both annual and seasonal scales, with the root mean square error (RMSE), mean relative error (MRE), and mean absolute error (MAE). The results indicate that the developed model in this study outperforms the method that builds transfer function using the gauge values. There is a large improvement in the results when using a residual correction with meteorological station observations. In comparison with other three classical interpolators, HASM shows better performance in modifying the residual produced by local regression method. The success of the developed technique lies in the effective use of the datasets and the modification process of the residual by using HASM. The results from the future climate scenarios show that precipitation exhibits overall increasing trend from T1 (2011-2040) to T2 (2041-2070) and T2 to T3 (2071-2100) in RCP2.6, RCP4.5, and RCP8.5 emission scenarios. The most significant increase occurs in RCP8.5 from T2 to T3, while the lowest increase is found in RCP2.6 from T2 to T3, increased by 47.11 and 2.12 mm, respectively.

  9. Finite volume schemes of very high order of accuracy for stiff hyperbolic balance laws

    Science.gov (United States)

    Dumbser, Michael; Enaux, Cedric; Toro, Eleuterio F.

    2008-04-01

    In this article, we propose a new class of finite volume schemes of arbitrary accuracy in space and time for systems of hyperbolic balance laws with stiff source terms. The new class of schemes is based on a three stage procedure. First a high-order WENO reconstruction procedure is applied to the cell averages at the current time level. Second, the temporal evolution of the reconstruction polynomials is computed locally inside each cell using the governing equations. In the original ENO scheme of Harten et al. and in the ADER schemes of Titarev and Toro, this time evolution is achieved via a Taylor series expansion where the time derivatives are computed by repeated differentiation of the governing PDE with respect to space and time, i.e. by applying the so-called Cauchy-Kovalewski procedure. However, this approach is not able to handle stiff source terms. Therefore, we present a new strategy that only replaces the Cauchy-Kovalewski procedure compared to the previously mentioned schemes. For the time-evolution part of the algorithm, we introduce a local space-time discontinuous Galerkin (DG) finite element scheme that is able to handle also stiff source terms. This step is the only part of the algorithm which is locally implicit. The third and last step of the proposed ADER finite volume schemes consists of the standard explicit space-time integration over each control volume, using the local space-time DG solutions at the Gaussian integration points for the intercell fluxes and for the space-time integral over the source term. We will show numerical convergence studies for nonlinear systems in one space dimension with both non-stiff and with very stiff source terms up to sixth order of accuracy in space and time. The application of the new method to a large set of different test cases is shown, in particular the stiff scalar model problem of LeVeque and Yee [R.J. LeVeque, H.C. Yee, A study of numerical methods for hyperbolic conservation laws with stiff source

  10. The regulatory benefits of high levels of affect perception accuracy: a process analysis of reactions to stressors in daily life.

    Science.gov (United States)

    Robinson, Michael D; Moeller, Sara K; Buchholz, Maria M; Boyd, Ryan L; Troop-Gordon, Wendy

    2012-08-01

    Individuals attuned to affective signals from the environment may possess an advantage in the emotion-regulation realm. In two studies (total n = 151), individual differences in affective perception accuracy were assessed in an objective, performance-based manner. Subsequently, the same individuals completed daily diary protocols in which daily stressor levels were reported as well as problematic states shown to be stress-reactive in previous studies. In both studies, individual differences in affect perception accuracy interacted with daily stressor levels to predict the problematic outcomes. Daily stressors precipitated problematic reactions--whether depressive feelings (study 1) or somatic symptoms (study 2)--at low levels of affect perception accuracy, but did not do so at high levels of affect perception accuracy. The findings support a regulatory view of such perceptual abilities. Implications for understanding emotion regulation processes, emotional intelligence, and individual differences in reactivity are discussed.

  11. Accuracy of hiatal hernia detection with esophageal high-resolution manometry.

    Science.gov (United States)

    Weijenborg, P W; van Hoeij, F B; Smout, A J P M; Bredenoord, A J

    2015-02-01

    The diagnosis of a sliding hiatal hernia is classically made with endoscopy or barium esophagogram. Spatial separation of the lower esophageal sphincter (LES) and diaphragm, the hallmark of hiatal hernia, can also be observed on high-resolution manometry (HRM), but the diagnostic accuracy of this finding has not yet been investigated. To determine the diagnostic value of HRM in the detection of hiatal hernia. HRM recordings, endoscopy reports, and barium esophagograms of 90 patients were analyzed for the presence and size of a hiatal hernia. The diagnostic value of a hernia specific HRM pressure pattern was calculated, and the agreement of HRM with endoscopy and barium esophagogram for the assessment of hernia size. HRM was found to be highly sensitive and specific for hiatal hernia detection, with a sensitivity of 92% and specificity of 95%, exceeding the sensitivity of endoscopy or radiography alone (both 73%). Patients with a hiatal hernia on HRM were manometrically characterized by an esophagogastric junction (EGJ) with partial or complete separation of the LES and crural diaphragm (CD), the latter being associated with significantly lower EGJ pressure. A cutoff value of spatial LES-CD separation on HRM of 1.85 cm yielded the optimal performance in identifying hiatal hernia. Agreement between HRM, endoscopy, and radiography for size of hiatal hernias was good (ICC [95% CI] 0.74 [0.65-0.82]). With HRM, the presence or absence and size of a hiatal hernia can be assessed with greater sensitivity than with endoscopy or radiography alone. © 2015 John Wiley & Sons Ltd.

  12. Achieving numerical accuracy and high performance using recursive tile LU factorization with partial pivoting

    KAUST Repository

    Dongarra, Jack

    2013-09-18

    The LU factorization is an important numerical algorithm for solving systems of linear equations in science and engineering and is a characteristic of many dense linear algebra computations. For example, it has become the de facto numerical algorithm implemented within the LINPACK benchmark to rank the most powerful supercomputers in the world, collected by the TOP500 website. Multicore processors continue to present challenges to the development of fast and robust numerical software due to the increasing levels of hardware parallelism and widening gap between core and memory speeds. In this context, the difficulty in developing new algorithms for the scientific community resides in the combination of two goals: achieving high performance while maintaining the accuracy of the numerical algorithm. This paper proposes a new approach for computing the LU factorization in parallel on multicore architectures, which not only improves the overall performance but also sustains the numerical quality of the standard LU factorization algorithm with partial pivoting. While the update of the trailing submatrix is computationally intensive and highly parallel, the inherently problematic portion of the LU factorization is the panel factorization due to its memory-bound characteristic as well as the atomicity of selecting the appropriate pivots. Our approach uses a parallel fine-grained recursive formulation of the panel factorization step and implements the update of the trailing submatrix with the tile algorithm. Based on conflict-free partitioning of the data and lockless synchronization mechanisms, our implementation lets the overall computation flow naturally without contention. The dynamic runtime system called QUARK is then able to schedule tasks with heterogeneous granularities and to transparently introduce algorithmic lookahead. The performance results of our implementation are competitive compared to the currently available software packages and libraries. For example

  13. DIRECT GEOREFERENCING : A NEW STANDARD IN PHOTOGRAMMETRY FOR HIGH ACCURACY MAPPING

    Directory of Open Access Journals (Sweden)

    A. Rizaldy

    2012-07-01

    Full Text Available Direct georeferencing is a new method in photogrammetry, especially in the digital camera era. Theoretically, this method does not require ground control points (GCP and the Aerial Triangulation (AT, to process aerial photography into ground coordinates. Compared with the old method, this method has three main advantages: faster data processing, simple workflow and less expensive project, at the same accuracy. Direct georeferencing using two devices, GPS and IMU. GPS recording the camera coordinates (X, Y, Z, and IMU recording the camera orientation (omega, phi, kappa. Both parameters merged into Exterior Orientation (EO parameter. This parameters required for next steps in the photogrammetric projects, such as stereocompilation, DSM generation, orthorectification and mosaic. Accuracy of this method was tested on topographic map project in Medan, Indonesia. Large-format digital camera Ultracam X from Vexcel is used, while the GPS / IMU is IGI AeroControl. 19 Independent Check Point (ICP were used to determine the accuracy. Horizontal accuracy is 0.356 meters and vertical accuracy is 0.483 meters. Data with this accuracy can be used for 1:2.500 map scale project.

  14. Numerical simulation for accuracy of velocity analysis in small-scale high-resolution marine multichannel seismic technology

    Science.gov (United States)

    Luo, Di; Cai, Feng; Wu, Zhiqiang

    2017-06-01

    When used with large energy sparkers, marine multichannel small-scale high-resolution seismic detection technology has a high resolution, high-detection precision, a wide applicable range, and is very flexible. Positive results have been achieved in submarine geological research, particularly in the investigation of marine gas hydrates. However, the amount of traveltime difference information is reduced for the velocity analysis under conditions of a shorter spread length, thus leading to poorer focusing of the velocity spectrum energy group and a lower accuracy of the velocity analysis. It is thus currently debatable whether the velocity analysis accuracy of short-arrangement multichannel seismic detection technology is able to meet the requirements of practical application in natural gas hydrate exploration. Therefore, in this study the bottom boundary of gas hydrates (Bottom Simulating Reflector, BSR) is used to conduct numerical simulation to discuss the accuracy of the velocity analysis related to such technology. Results show that a higher dominant frequency and smaller sampling interval are not only able to improve the seismic resolution, but they also compensate for the defects of the short-arrangement, thereby improving the accuracy of the velocity analysis. In conclusion, the accuracy of the velocity analysis in this small-scale, high-resolution, multi-channel seismic detection technology meets the requirements of natural gas hydrate exploration.

  15. High-Accuracy Tidal Flat Digital Elevation Model Construction Using TanDEM-X Science Phase Data

    Science.gov (United States)

    Lee, Seung-Kuk; Ryu, Joo-Hyung

    2017-01-01

    This study explored the feasibility of using TanDEM-X (TDX) interferometric observations of tidal flats for digital elevation model (DEM) construction. Our goal was to generate high-precision DEMs in tidal flat areas, because accurate intertidal zone data are essential for monitoring coastal environment sand erosion processes. To monitor dynamic coastal changes caused by waves, currents, and tides, very accurate DEMs with high spatial resolution are required. The bi- and monostatic modes of the TDX interferometer employed during the TDX science phase provided a great opportunity for highly accurate intertidal DEM construction using radar interferometry with no time lag (bistatic mode) or an approximately 10-s temporal baseline (monostatic mode) between the master and slave synthetic aperture radar image acquisitions. In this study, DEM construction in tidal flat areas was first optimized based on the TDX system parameters used in various TDX modes. We successfully generated intertidal zone DEMs with 57-m spatial resolutions and interferometric height accuracies better than 0.15 m for three representative tidal flats on the west coast of the Korean Peninsula. Finally, we validated these TDX DEMs against real-time kinematic-GPS measurements acquired in two tidal flat areas; the correlation coefficient was 0.97 with a root mean square error of 0.20 m.

  16. The research of digital circuit system for high accuracy CCD of portable Raman spectrometer

    Science.gov (United States)

    Yin, Yu; Cui, Yongsheng; Zhang, Xiuda; Yan, Huimin

    2013-08-01

    The Raman spectrum technology is widely used for it can identify various types of molecular structure and material. The portable Raman spectrometer has become a hot direction of the spectrometer development nowadays for its convenience in handheld operation and real-time detection which is superior to traditional Raman spectrometer with heavy weight and bulky size. But there is still a gap for its measurement sensitivity between portable and traditional devices. However, portable Raman Spectrometer with Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) technology can enhance the Raman signal significantly by several orders of magnitude, giving consideration in both measurement sensitivity and mobility. This paper proposed a design and implementation of driver and digital circuit for high accuracy CCD sensor, which is core part of portable spectrometer. The main target of the whole design is to reduce the dark current generation rate and increase signal sensitivity during the long integration time, and in the weak signal environment. In this case, we use back-thinned CCD image sensor from Hamamatsu Corporation with high sensitivity, low noise and large dynamic range. In order to maximize this CCD sensor's performance and minimize the whole size of the device simultaneously to achieve the project indicators, we delicately designed a peripheral circuit for the CCD sensor. The design is mainly composed with multi-voltage circuit, sequential generation circuit, driving circuit and A/D transition parts. As the most important power supply circuit, the multi-voltage circuits with 12 independent voltages are designed with reference power supply IC and set to specified voltage value by the amplifier making up the low-pass filter, which allows the user to obtain a highly stable and accurate voltage with low noise. What's more, to make our design easy to debug, CPLD is selected to generate sequential signal. The A/D converter chip consists of a correlated

  17. In-depth, high-accuracy proteomics of sea urchin tooth organic matrix

    Directory of Open Access Journals (Sweden)

    Mann Matthias

    2008-12-01

    Full Text Available Abstract Background The organic matrix contained in biominerals plays an important role in regulating mineralization and in determining biomineral properties. However, most components of biomineral matrices remain unknown at present. In sea urchin tooth, which is an important model for developmental biology and biomineralization, only few matrix components have been identified. The recent publication of the Strongylocentrotus purpuratus genome sequence rendered possible not only the identification of genes potentially coding for matrix proteins, but also the direct identification of proteins contained in matrices of skeletal elements by in-depth, high-accuracy proteomic analysis. Results We identified 138 proteins in the matrix of tooth powder. Only 56 of these proteins were previously identified in the matrices of test (shell and spine. Among the novel components was an interesting group of five proteins containing alanine- and proline-rich neutral or basic motifs separated by acidic glycine-rich motifs. In addition, four of the five proteins contained either one or two predicted Kazal protease inhibitor domains. The major components of tooth matrix were however largely identical to the set of spicule matrix proteins and MSP130-related proteins identified in test (shell and spine matrix. Comparison of the matrices of crushed teeth to intact teeth revealed a marked dilution of known intracrystalline matrix proteins and a concomitant increase in some intracellular proteins. Conclusion This report presents the most comprehensive list of sea urchin tooth matrix proteins available at present. The complex mixture of proteins identified may reflect many different aspects of the mineralization process. A comparison between intact tooth matrix, presumably containing odontoblast remnants, and crushed tooth matrix served to differentiate between matrix components and possible contributions of cellular remnants. Because LC-MS/MS-based methods directly

  18. Functional knowledge transfer for high-accuracy prediction of under-studied biological processes.

    Directory of Open Access Journals (Sweden)

    Christopher Y Park

    Full Text Available A key challenge in genetics is identifying the functional roles of genes in pathways. Numerous functional genomics techniques (e.g. machine learning that predict protein function have been developed to address this question. These methods generally build from existing annotations of genes to pathways and thus are often unable to identify additional genes participating in processes that are not already well studied. Many of these processes are well studied in some organism, but not necessarily in an investigator's organism of interest. Sequence-based search methods (e.g. BLAST have been used to transfer such annotation information between organisms. We demonstrate that functional genomics can complement traditional sequence similarity to improve the transfer of gene annotations between organisms. Our method transfers annotations only when functionally appropriate as determined by genomic data and can be used with any prediction algorithm to combine transferred gene function knowledge with organism-specific high-throughput data to enable accurate function prediction. We show that diverse state-of-art machine learning algorithms leveraging functional knowledge transfer (FKT dramatically improve their accuracy in predicting gene-pathway membership, particularly for processes with little experimental knowledge in an organism. We also show that our method compares favorably to annotation transfer by sequence similarity. Next, we deploy FKT with state-of-the-art SVM classifier to predict novel genes to 11,000 biological processes across six diverse organisms and expand the coverage of accurate function predictions to processes that are often ignored because of a dearth of annotated genes in an organism. Finally, we perform in vivo experimental investigation in Danio rerio and confirm the regulatory role of our top predicted novel gene, wnt5b, in leftward cell migration during heart development. FKT is immediately applicable to many bioinformatics

  19. High-accuracy biaxial optical extensometer based on 2D digital image correlation

    Science.gov (United States)

    Zhu, Feipeng; Gong, Yan; Bai, Pengxiang; Jiang, Zhencheng; Lei, Dong

    2017-08-01

    In two-dimensional digital image correlation (2D-DIC), the optical axis of the camera must be exactly perpendicular to the object surface to avoid the generation of out-of-plane displacement, which leads to low strain accuracy. In this work, we first studied the strain accuracy of a common optical extensometer when the optical axis of the camera is not perpendicular to the specimen surface. Derivation reveals that even a very small oblique angle θ will introduce a considerable strain error and that an opposite oblique angle θ generates an opposite strain error of the same magnitude. Therefore, taking the strain average of these two optical extensometers can almost entirely eliminate such effect of non-perpendicularity, which has the same form as the optical extensometer realized by dual-reflector imaging. Because the transverse strain of a specimen is less than its axial strain, the measurement of transverse strain requires higher strain-measurement accuracy. With the aid of a self-designed right-angled apparatus, we conveniently extend this 1D extensometer to a 2D situation, which is called the biaxial optical extensometer. Uniaxial tensile tests of a stainless-steel specimen are conducted to evaluate the strain accuracy of the biaxial optical extensometer quantitatively. Experimental results show that the transverse and axial strains obtained using the proposed biaxial extensometer are in good agreement with those obtained using strain gauges and that the proposed extensometer achieves higher strain accuracy compared to the 3D-DIC extensometer.

  20. Simplifying and expanding analytical capabilities for various classes of doping agents by means of direct urine injection high performance liquid chromatography high resolution/high accuracy mass spectrometry.

    Science.gov (United States)

    Görgens, Christian; Guddat, Sven; Thomas, Andreas; Wachsmuth, Philipp; Orlovius, Anne-Katrin; Sigmund, Gerd; Thevis, Mario; Schänzer, Wilhelm

    2016-11-30

    So far, in sports drug testing compounds of different classes are processed and measured using different screening procedures. The constantly increasing number of samples in doping analysis, as well as the large number of substances with doping related, pharmacological effects require the development of even more powerful assays than those already employed in sports drug testing, indispensably with reduced sample preparation procedures. The analysis of native urine samples after direct injection provides a promising analytical approach, which thereby possesses a broad applicability to many different compounds and their metabolites, without a time-consuming sample preparation. In this study, a novel multi-target approach based on liquid chromatography and high resolution/high accuracy mass spectrometry is presented to screen for more than 200 analytes of various classes of doping agents far below the required detection limits in sports drug testing. Here, classic groups of drugs as diuretics, stimulants, β2-agonists, narcotics and anabolic androgenic steroids as well as various newer target compounds like hypoxia-inducible factor (HIF) stabilizers, selective androgen receptor modulators (SARMs), selective estrogen receptor modulators (SERMs), plasma volume expanders and other doping related compounds, listed in the 2016 WADA prohibited list were implemented. As a main achievement, growth hormone releasing peptides could be implemented, which chemically belong to the group of small peptides (0.99), limit of detection (0.1-25ng/mL; 3'OH-stanozolol glucuronide: 50pg/mL; dextran/HES: 10μg/mL) and matrix effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Judgment of Learning Accuracy in High-functioning Adolescents and Adults with Autism Spectrum Disorder.

    Science.gov (United States)

    Grainger, Catherine; Williams, David M; Lind, Sophie E

    2016-11-01

    This study explored whether adults and adolescents with autism spectrum disorder (ASD) demonstrate difficulties making metacognitive judgments, specifically judgments of learning. Across two experiments, the study examined whether individuals with ASD could accurately judge whether they had learnt a piece of information (in this case word pairs). In Experiment 1, adults with ASD demonstrated typical accuracy on a standard 'cue-alone' judgment of learning (JOL) task, compared to age- and IQ-matched neurotypical adults. Additionally, in Experiment 2, adolescents with ASD demonstrated typical accuracy on both a standard 'cue-alone' JOL task, and a 'cue-target' JOL task. These results suggest that JOL accuracy is unimpaired in ASD. These results have important implications for both theories of metacognition in ASD and educational practise.

  2. The CERAD neuropsychological assessment battery total score detects and predicts Alzheimer disease dementia with high diagnostic accuracy.

    Science.gov (United States)

    Wolfsgruber, Steffen; Jessen, Frank; Wiese, Birgitt; Stein, Janine; Bickel, Horst; Mösch, Edelgard; Weyerer, Siegfried; Werle, Jochen; Pentzek, Michael; Fuchs, Angela; Köhler, Mirjam; Bachmann, Cadja; Riedel-Heller, Steffi G; Scherer, Martin; Maier, Wolfgang; Wagner, Michael

    2014-10-01

    To establish the diagnostic accuracy of the Total Score of the Consortium to Establish a Registry for Alzheimer's Disease neuropsychological assessment battery (CERAD-NP) both for cross-sectional discrimination of Alzheimer disease (AD) dementia and short-term prediction of incident AD dementia. Longitudinal cohort study with two assessments at a 1.5-year interval. Primary care sample randomly recruited via medical record registries. As part of the German Study on Ageing, Cognition, and Dementia (AgeCoDe), a sample of elderly individuals (N = 1,606; mean age: 84 years) was assessed. Subjects were assessed with the CERAD-NP and followed up for 18 months (97.6% follow-up rate). Logistic regression and receiver-operating-characteristic (ROC) curve analysis were used to compare the diagnostic accuracy of the CERAD-NP Total Score (CTS) with that of single CERAD-NP scores and the Mini-Mental-State-Examination (MMSE) score. ROC curve analysis resulted in excellent (area under the curve [AUC]: 0.97) cross-sectional discrimination between non-AD and AD dementia subjects. Prediction of incident AD dementia with the CTS was also very good (AUC: 0.89), and was significantly better than prediction based on the MMSE. The cross-sectional results confirm that the CTS is a highly accurate diagnostic tool for detecting AD dementia in elderly primary care patients. In addition, we provide evidence that the CTS is also accurate for the prediction of incident AD dementia. These findings further support the validity of the CTS as an index of overall cognitive functioning for detection and prediction of AD dementia. Copyright © 2014 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  3. High stakes and high emotions: providing safe care in Canadian emergency departments

    Directory of Open Access Journals (Sweden)

    Ali S

    2017-01-01

    Full Text Available Samina Ali,1,2 Denise Thomson,3 Timothy A D Graham,4 Sean E Rickard,3 Antonia S Stang5 1Women and Children’s Health Research Institute, 2Department of Pediatrics, 3Cochrane Child Health Field, Department of Pediatrics, University of Alberta, Edmonton, 4Department of Emergency Medicine, 5Section of Emergency Medicine, Department of Pediatrics, University of Calgary, Calgary, AB, Canada Background: The high-paced, unpredictable environment of the emergency department (ED contributes to errors in patient safety. The ED setting becomes even more challenging when dealing with critically ill patients, particularly with children, where variations in size, weight, and form present practical difficulties in many aspects of care. In this commentary, we will explore the impact of the health care providers’ emotional reactions while caring for critically ill patients, and how this can be interpreted and addressed as a patient safety issue. Discussion: ED health care providers encounter high-stakes, high-stress clinical scenarios, such as pediatric cardiac arrest or resuscitation. This health care providers’ stress, and at times, distress, and its potential contribution to medical error, is underrepresented in the current medical literature. Most patient safety research is limited to error reporting systems, especially medication-related ones, an approach that ignores the effects of health care provider stress as a source of error, and limits our ability to learn from the event. Ways to mitigate this stress and avoid this type of patient safety concern might include simulation training for rare, high-acuity events, use of pre-determined clinical order sets, and post-event debriefing. Conclusion: While there are physiologic and anatomic differences that contribute to patient safety, we believe that they are insufficient to explain the need to address critical life-threatening event-related patient safety issues for both adults and, especially, children

  4. Research on the classification result and accuracy of building windows in high resolution satellite images: take the typical rural buildings in Guangxi, China, as an example

    Science.gov (United States)

    Li, Baishou; Gao, Yujiu

    2015-12-01

    The information extracted from the high spatial resolution remote sensing images has become one of the important data sources of the GIS large scale spatial database updating. The realization of the building information monitoring using the high resolution remote sensing, building small scale information extracting and its quality analyzing has become an important precondition for the applying of the high-resolution satellite image information, because of the large amount of regional high spatial resolution satellite image data. In this paper, a clustering segmentation classification evaluation method for the high resolution satellite images of the typical rural buildings is proposed based on the traditional KMeans clustering algorithm. The factors of separability and building density were used for describing image classification characteristics of clustering window. The sensitivity of the factors influenced the clustering result was studied from the perspective of the separability between high image itself target and background spectrum. This study showed that the number of the sample contents is the important influencing factor to the clustering accuracy and performance, the pixel ratio of the objects in images and the separation factor can be used to determine the specific impact of cluster-window subsets on the clustering accuracy, and the count of window target pixels (Nw) does not alone affect clustering accuracy. The result can provide effective research reference for the quality assessment of the segmentation and classification of high spatial resolution remote sensing images.

  5. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs.

    Directory of Open Access Journals (Sweden)

    Alexander T Dilthey

    2016-10-01

    Full Text Available Genetic variation at the Human Leucocyte Antigen (HLA genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG framework. First, we construct a PRG for 46 (mostly HLA genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1 and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data. Of 158 alleles tested, we correctly infer 157 alleles (99.4%. We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample remain a

  6. Parallel High Order Accuracy Methods Applied to Non-Linear Hyperbolic Equations and to Problems in Materials Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Jan Hesthaven

    2012-02-06

    Final report for DOE Contract DE-FG02-98ER25346 entitled Parallel High Order Accuracy Methods Applied to Non-Linear Hyperbolic Equations and to Problems in Materials Sciences. Principal Investigator Jan S. Hesthaven Division of Applied Mathematics Brown University, Box F Providence, RI 02912 Jan.Hesthaven@Brown.edu February 6, 2012 Note: This grant was originally awarded to Professor David Gottlieb and the majority of the work envisioned reflects his original ideas. However, when Prof Gottlieb passed away in December 2008, Professor Hesthaven took over as PI to ensure proper mentoring of students and postdoctoral researchers already involved in the project. This unusual circumstance has naturally impacted the project and its timeline. However, as the report reflects, the planned work has been accomplished and some activities beyond the original scope have been pursued with success. Project overview and main results The effort in this project focuses on the development of high order accurate computational methods for the solution of hyperbolic equations with application to problems with strong shocks. While the methods are general, emphasis is on applications to gas dynamics with strong shocks.

  7. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    Science.gov (United States)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  8. High-accuracy interferometric measurements of flatness and parallelism of a step gauge

    CSIR Research Space (South Africa)

    Kruger, OA

    2001-01-01

    Full Text Available The most commonly used method in the calibration of step gauges is the coordinate measuring machine (CMM), equipped with a laser interferometer for the highest accuracy. This paper describes a modification to a length-bar measuring machine...

  9. The Effects of Individual or Group Guidelines on the Calibration Accuracy and Achievement of High School Biology Students

    Science.gov (United States)

    Bol, Linda; Hacker, Douglas J.; Walck, Camilla C.; Nunnery, John A.

    2012-01-01

    A 2 x 2 factorial design was employed in a quasi-experiment to investigate the effects of guidelines in group or individual settings on the calibration accuracy and achievement of 82 high school biology students. Significant main effects indicated that calibration practice with guidelines and practice in group settings increased prediction and…

  10. Algorithm of dynamic regulation of a system of duct, for a high accuracy climatic system

    Science.gov (United States)

    Arbatskiy, A. A.; Afonina, G. N.; Glazov, V. S.

    2017-11-01

    Currently, major part of climatic system, are stationary in projected mode only. At the same time, many modern industrial sites, require constant or periodical changes in technological process. That is 80% of the time, the industrial site is not require ventilation system in projected mode and high precision of climatic parameters must maintain. While that not constantly is in use for climatic systems, which use in parallel for different rooms, we will be have a problem for balance of duct system. For this problem, was created the algorithm for quantity regulation, with minimal changes. Dynamic duct system: Developed of parallel control system of air balance, with high precision of climatic parameters. The Algorithm provide a permanent pressure in main duct, in different a flow of air. Therefore, the ending devises air flow have only one parameter for regulation – flaps open area. Precision of regulation increase and the climatic system provide high precision for temperature and humidity (0,5C for temperature, 5% for relative humidity). Result: The research has been made in CFD-system – PHOENICS. Results for velocity of air in duct, for pressure of air in duct for different operation mode, has been obtained. Equation for air valves positions, with different parameters for climate in room’s, has been obtained. Energy saving potential for dynamic duct system, for different types of a rooms, has been calculated.

  11. Estimating subsurface water volumes and transit times in Hokkaido river catchments, Japan, using high-accuracy tritium analysis

    Science.gov (United States)

    Gusyev, Maksym; Yamazaki, Yusuke; Morgenstern, Uwe; Stewart, Mike; Kashiwaya, Kazuhisa; Hirai, Yasuyuki; Kuribayashi, Daisuke; Sawano, Hisaya

    2015-04-01

    The goal of this study is to estimate subsurface water transit times and volumes in headwater catchments of Hokkaido, Japan, using the New Zealand high-accuracy tritium analysis technique. Transit time provides insights into the subsurface water storage and therefore provides a robust and quick approach to quantifying the subsurface groundwater volume. Our method is based on tritium measurements in river water. Tritium is a component of meteoric water, decays with a half-life of 12.32 years, and is inert in the subsurface after the water enters the groundwater system. Therefore, tritium is ideally suited for characterization of the catchment's responses and can provide information on mean water transit times up to 200 years. Only in recent years has it become possible to use tritium for dating of stream and river water, due to the fading impact of the bomb-tritium from thermo-nuclear weapons testing, and due to improved measurement accuracy for the extremely low natural tritium concentrations. Transit time of the water discharge is one of the most crucial parameters for understanding the response of catchments and estimating subsurface water volume. While many tritium transit time studies have been conducted in New Zealand, only a limited number of tritium studies have been conducted in Japan. In addition, the meteorological, orographic and geological conditions of Hokkaido Island are similar to those in parts of New Zealand, allowing for comparison between these regions. In 2014, three field trips were conducted in Hokkaido in June, July and October to sample river water at river gauging stations operated by the Ministry of Land, Infrastructure, Transport and Tourism (MLIT). These stations have altitudes between 36 m and 860 m MSL and drainage areas between 45 and 377 km2. Each sampled point is located upstream of MLIT dams, with hourly measurements of precipitation and river water levels enabling us to distinguish between the snow melt and baseflow contributions

  12. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  13. Implementation of two telemeter designs for high accuracy laser ranging of kilometer scale distances in space

    Science.gov (United States)

    Courde, C.; Phung, D. H.; Brillet, A.; Lintz, M.

    2017-11-01

    We present two different laser ranging systems under development, both based on the use of a high frequency modulated beam. The first range meter makes no use of interferometry: only the phase of the return beam is detected, in a way that rejects cyclic errors due to optical and electronic crosstalk. An Allan deviation slightly better than 10nm has been obtained with this simple system. The other range meter should provide better resolution, at the expense of a somewhat more sophisticated procedure, as it involves both time-of-flight and interferometry measurements.

  14. Automatic J–A Model Parameter Tuning Algorithm for High Accuracy Inrush Current Simulation

    Directory of Open Access Journals (Sweden)

    Xishan Wen

    2017-04-01

    Full Text Available Inrush current simulation plays an important role in many tasks of the power system, such as power transformer protection. However, the accuracy of the inrush current simulation can hardly be ensured. In this paper, a Jiles–Atherton (J–A theory based model is proposed to simulate the inrush current of power transformers. The characteristics of the inrush current curve are analyzed and results show that the entire inrush current curve can be well featured by the crest value of the first two cycles. With comprehensive consideration of both of the features of the inrush current curve and the J–A parameters, an automatic J–A parameter estimation algorithm is proposed. The proposed algorithm can obtain more reasonable J–A parameters, which improve the accuracy of simulation. Experimental results have verified the efficiency of the proposed algorithm.

  15. SFOL Pulse: A High Accuracy DME Pulse for Alternative Aircraft Position and Navigation

    Directory of Open Access Journals (Sweden)

    Euiho Kim

    2017-09-01

    Full Text Available In the Federal Aviation Administration’s (FAA performance based navigation strategy announced in 2016, the FAA stated that it would retain and expand the Distance Measuring Equipment (DME infrastructure to ensure resilient aircraft navigation capability during the event of a Global Navigation Satellite System (GNSS outage. However, the main drawback of the DME as a GNSS back up system is that it requires a significant expansion of the current DME ground infrastructure due to its poor distance measuring accuracy over 100 m. The paper introduces a method to improve DME distance measuring accuracy by using a new DME pulse shape. The proposed pulse shape was developed by using Genetic Algorithms and is less susceptible to multipath effects so that the ranging error reduces by 36.0–77.3% when compared to the Gaussian and Smoothed Concave Polygon DME pulses, depending on noise environment.

  16. Identifying wrist fracture patients with high accuracy by automatic categorization of X-ray reports.

    Science.gov (United States)

    de Bruijn, Berry; Cranney, Ann; O'Donnell, Siobhan; Martin, Joel D; Forster, Alan J

    2006-01-01

    The authors performed this study to determine the accuracy of several text classification methods to categorize wrist x-ray reports. We randomly sampled 751 textual wrist x-ray reports. Two expert reviewers rated the presence (n = 301) or absence (n = 450) of an acute fracture of wrist. We developed two information retrieval (IR) text classification methods and a machine learning method using a support vector machine (TC-1). In cross-validation on the derivation set (n = 493), TC-1 outperformed the two IR based methods and six benchmark classifiers, including Naive Bayes and a Neural Network. In the validation set (n = 258), TC-1 demonstrated consistent performance with 93.8% accuracy; 95.5% sensitivity; 92.9% specificity; and 87.5% positive predictive value. TC-1 was easy to implement and superior in performance to the other classification methods.

  17. Locating very high energy gamma-ray sources with arcminute accuracy

    Science.gov (United States)

    Akerlof, C. W.; Cawley, M. F.; Chantell, M.; Harris, K.; Lawrence, M. A.; Fegan, D. J.; Lang, M. J.; Hillas, A. M.; Jennings, D. G.; Lamb, R. C.

    1991-01-01

    The angular accuracy of gamma-ray detectors is intrinsically limited by the physical processes involved in photon detection. Although a number of pointlike sources were detected by the COS B satellite, only two have been unambiguously identified by time signature with counterparts at longer wavelengths. By taking advantage of the extended longitudinal structure of VHE gamma-ray showers, measurements in the TeV energy range can pinpoint source coordinates to arcminute accuracy. This has now been demonstrated with new data analysis procedures applied to observations of the Crab Nebula using Cherenkov air shower imaging techniques. With two telescopes in coincidence, the individual event circular probable error will be 0.13 deg. The half-cone angle of the field of view is effectively 1 deg.

  18. High accuracy microwave frequency measurement based on single-drive dual-parallel Mach-Zehnder modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Pang, Xiaodan; Deng, Lei

    2011-01-01

    A novel approach for broadband microwave frequency measurement by employing a single-drive dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. Based on bias manipulations of the modulator, conventional frequency-to-power mapping technique is developed by performing a...... 10−3 relative error. This high accuracy frequency measurement technique is a promising candidate for high-speed electronic warfare and defense applications....

  19. Building high-accuracy thermal simulation for evaluation of thermal comfort in real houses

    OpenAIRE

    Nguyen, Hoaison; Makino, Yoshiki; Lim, Azman Osman; Tan, Yasuo; Shinoda, Yoichi

    2013-01-01

    Thermal comfort is an essential aspect for the control and verification of many smart home services. In this research, we design and implement simulation which models thermal environment of a smart house testbed. Our simulation can be used to evaluate thermal comfort in various conditions of home environment. In order to increase the accuracy of the simulation, we measure thermal-related parameters of the house such as temperature, humidity, solar radiation by the use of sensors and perform p...

  20. Positional accuracy in RPC point determination based on high-resolution imagery

    Science.gov (United States)

    Meng, Han; Liu, Yongliang; Zhang, Jingxiong; Gong, Hao

    2007-06-01

    The rational function model (RFM), also known as rational polynomial coefficients (RPCs) or rational polynomial camera (RPC) model, is a generalized sensor model. Different from rigorous sensor model, RFM does not need to obtain the interior and exterior orientation geometry and other physical properties associated with the physical sensor. RFMs were first adopted by Space Imaging company as a replacement for rigorous sensor models, and it drew much attention from the commercial satellite data vendors who rapidly followed the suit in order to protect the confidential information of the sensors. This paper focuses on the solution for rational polynomial coefficients, RFM-based stereo-model reconstitution, and positional accuracy analysis. As RPCs do not have obvious physical meanings and their solution is iterative, analytical approaches to accuracy analysis may not be feasible; computer simulation is thus adopted to quantify accuracy in RPC-determined positional data. The simulation-based strategy is efficient in mapping local features in positional errors, which contain both the systematic and random components.

  1. Will it Blend? Visualization and Accuracy Evaluation of High-Resolution Fuzzy Vegetation Maps

    Science.gov (United States)

    Zlinszky, A.; Kania, A.

    2016-06-01

    Instead of assigning every map pixel to a single class, fuzzy classification includes information on the class assigned to each pixel but also the certainty of this class and the alternative possible classes based on fuzzy set theory. The advantages of fuzzy classification for vegetation mapping are well recognized, but the accuracy and uncertainty of fuzzy maps cannot be directly quantified with indices developed for hard-boundary categorizations. The rich information in such a map is impossible to convey with a single map product or accuracy figure. Here we introduce a suite of evaluation indices and visualization products for fuzzy maps generated with ensemble classifiers. We also propose a way of evaluating classwise prediction certainty with "dominance profiles" visualizing the number of pixels in bins according to the probability of the dominant class, also showing the probability of all the other classes. Together, these data products allow a quantitative understanding of the rich information in a fuzzy raster map both for individual classes and in terms of variability in space, and also establish the connection between spatially explicit class certainty and traditional accuracy metrics. These map products are directly comparable to widely used hard boundary evaluation procedures, support active learning-based iterative classification and can be applied for operational use.

  2. High Accuracy Human Activity Recognition Based on Sparse Locality Preserving Projections.

    Directory of Open Access Journals (Sweden)

    Xiangbin Zhu

    Full Text Available Human activity recognition(HAR from the temporal streams of sensory data has been applied to many fields, such as healthcare services, intelligent environments and cyber security. However, the classification accuracy of most existed methods is not enough in some applications, especially for healthcare services. In order to improving accuracy, it is necessary to develop a novel method which will take full account of the intrinsic sequential characteristics for time-series sensory data. Moreover, each human activity may has correlated feature relationship at different levels. Therefore, in this paper, we propose a three-stage continuous hidden Markov model (TSCHMM approach to recognize human activities. The proposed method contains coarse, fine and accurate classification. The feature reduction is an important step in classification processing. In this paper, sparse locality preserving projections (SpLPP is exploited to determine the optimal feature subsets for accurate classification of the stationary-activity data. It can extract more discriminative activities features from the sensor data compared with locality preserving projections. Furthermore, all of the gyro-based features are used for accurate classification of the moving data. Compared with other methods, our method uses significantly less number of features, and the over-all accuracy has been obviously improved.

  3. High accuracy integrated global positioning system/inertial navigation system LDRD: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Owen, T.E.; Meindl, M.A.; Fellerhoff, J.R.

    1997-03-01

    This report contains the results of a Sandia National Laboratories Directed Research and Development (LDRD) program to investigate the integration of Global Positioning System (GPS) and inertial navigation system (INS) technologies toward the goal of optimizing the navigational accuracy of the combined GPSANS system. The approach undertaken is to integrate the data from an INS, which has long term drifts, but excellent short term accuracy, with GPS carrier phase signal information, which is accurate to the sub-centimeter level, but requires continuous tracking of the GPS signals. The goal is to maintain a sub-meter accurate navigation solution while the vehicle is in motion by using the GPS measurements to estimate the INS navigation errors and then using the refined INS data to aid the GPS carrier phase cycle slip detection and correction and bridge dropouts in the GPS data. The work was expanded to look at GPS-based attitude determination, using multiple GPS receivers and antennas on a single platform, as a possible navigation aid. Efforts included not only the development of data processing algorithms and software, but also the collection and analysis of GPS and INS flight data aboard a Twin Otter aircraft. Finally, the application of improved navigation system accuracy to synthetic aperture radar (SAR) target location is examined.

  4. Use of a tick-borne disease manual increases accuracy of tick identification among primary care providers in Lyme disease endemic areas.

    Science.gov (United States)

    Butler, Amber D; Carlson, Meredith L; Nelson, Christina A

    2017-02-01

    Given the high incidence of tick bites and tick-borne diseases in the United States, it is important for primary care providers to recognize common ticks and the pathogens they may transmit. If a patient has removed and saved an attached tick, identifying the tick helps guide clinical management and determine whether antibiotic prophylaxis for Lyme disease is appropriate. To investigate providers' ability to recognize common ticks and the pathogens they may transmit, we asked 76 primary care providers from Lyme disease endemic areas to identify the common name or genus of preserved ticks found in their area. At baseline, 10.5%, 46.1%, and 57.9% of participants correctly identified an adult female blacklegged tick (engorged), dog tick, and lone star tick, respectively. Less than half of participants identified the three pathogens most frequently transmitted by blacklegged ticks. Use of a reference manual with tick photographs and drawings substantially improved identification of ticks and associated pathogens and therefore should be encouraged in clinical practice. Copyright © 2016 Elsevier GmbH. All rights reserved.

  5. Emergence of realism: Enhanced visual artistry and high accuracy of visual numerosity representation after left prefrontal damage.

    Science.gov (United States)

    Takahata, Keisuke; Saito, Fumie; Muramatsu, Taro; Yamada, Makiko; Shirahase, Joichiro; Tabuchi, Hajime; Suhara, Tetsuya; Mimura, Masaru; Kato, Motoichiro

    2014-05-01

    Over the last two decades, evidence of enhancement of drawing and painting skills due to focal prefrontal damage has accumulated. It is of special interest that most artworks created by such patients were highly realistic ones, but the mechanism underlying this phenomenon remains to be understood. Our hypothesis is that enhanced tendency of realism was associated with accuracy of visual numerosity representation, which has been shown to be mediated predominantly by right parietal functions. Here, we report a case of left prefrontal stroke, where the patient showed enhancement of artistic skills of realistic painting after the onset of brain damage. We investigated cognitive, functional and esthetic characteristics of the patient׳s visual artistry and visual numerosity representation. Neuropsychological tests revealed impaired executive function after the stroke. Despite that, the patient׳s visual artistry related to realism was rather promoted across the onset of brain damage as demonstrated by blind evaluation of the paintings by professional art reviewers. On visual numerical cognition tasks, the patient showed higher performance in comparison with age-matched healthy controls. These results paralleled increased perfusion in the right parietal cortex including the precuneus and intraparietal sulcus. Our data provide new insight into mechanisms underlying change in artistic style due to focal prefrontal lesion. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Driving the LHC Collimators’ Stepping Motors over 1 km with High Accuracy avoiding EMI Effects

    CERN Document Server

    Masi, A; Losito, R; Martino, M

    2011-01-01

    The LHC collimators are exposed to very high levels of radiation, which means that the power drivers must be installed far from the stepping motors that they drive. Due to the geometry of the underground installations, the distances can be up to 1 km. The long cables that connect the drivers to the motors behave as transmission lines modifying dramatically the impedance seen by the drivers and consequently jeopardizing the control performance of Pulse Width Modulation (PWM) drivers. In this paper we address this problem, provide an analytical model of the driver-cable-motor system and describe the analog solution we have developed to improve the performance of a typical off the shelf driver. Finally we characterize the improvement of the performances with measurements of positioning repeatability and show that electromagnetic emissions from the long cables are drastically reduced, making the use of stepping motors compatible with extremely sensitive instrumentation such as the LHC Beam Loss Monitors (BLM).

  7. High-accuracy measurement of the emission spectrum of liquid xenon in the vacuum ultraviolet region

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Keiko, E-mail: fujii-keiko-nv@ynu.jp [Faculty of Engineering, Yokohama National University, Yokohama, Kanagawa 240-8501 (Japan); Endo, Yuya; Torigoe, Yui; Nakamura, Shogo [Faculty of Engineering, Yokohama National University, Yokohama, Kanagawa 240-8501 (Japan); Haruyama, Tomiyoshi; Kasami, Katsuyu [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Mihara, Satoshi; Saito, Kiwamu; Sasaki, Shinichi [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); The Graduate School of Advanced Studies, Hayama, Kanagawa 240-0193 (Japan); Tawara, Hiroko [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan)

    2015-09-21

    The emission spectrum of cryogenic liquid xenon in the vacuum ultraviolet region was measured by irradiating liquid xenon with gamma-rays from a radioactive source. To achieve a high signal-to-noise ratio, we employed coincident photon counting. Additionally, the charge of the photo-sensor signals was measured to estimate the number of detected photons accurately. In addition, proper corrections were incorporated for the wavelength; response functions of the apparatus obtained using a low-pressure mercury lamp, and photon detection efficiencies of the optical system were considered. The obtained emission spectrum is found to be in the shape of a Gaussian function, with the center at 57,199±34 (stat.)±33 (syst.) cm{sup −1} (174.8±0.1 (stat.)±0.1 (syst.) nm) and the full width at half maximum of 3328±72 (stat.)±65 (syst.) cm{sup −1} (10.2±0.2 (stat.)±0.2 (sys.) nm). These results are the most accurate values obtained in terms of the data acquisition method and the calibration for the experimental system and provide valuable information regarding the high-precision instruments that employ a liquid-xenon scintillator.

  8. High-accuracy mass determination of unstable cesium and barium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Ames, F. [Mainz Univ. (Germany). Inst. fuer Physik; Audi, G.; Beck, D. [and others; ISOLDE Collaboration

    1999-02-01

    Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600000 and an accuracy of {delta}m {approx} 13 keV have been obtained. The masses of {sup 123,124,126}Ba and {sup 122m}Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model. (orig.)

  9. High-accuracy mass determination of neutron-rich rubidium and strontiumiIsotopes

    CERN Document Server

    Raimbault-Hartmann, H; Beck, D; Bollen, G; De Saint-Simon, M; Kluge, H J; König, M; Moore, R B; Schwarz, S; Savard, G; Szerypo, J

    2002-01-01

    The penning-trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of $^{88,89,90m,91,92,93,94}$Rb and $^{91- 95}$Sr. Using a resolving power of R $\\!\\scriptstyle\\approx$1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in the general mass adjustment.

  10. High-accuracy mass determination of unstable cesium and barium isotopes

    CERN Document Server

    Ames, F; Beck, D; Bollen, G; De Saint-Simon, M; Jertz, R; Kluge, H J; Kohl, A; König, M; Lunney, M D; Martel, I; Moore, R B; Otto, T; Patyk, Z; Raimbault-Hartmann, H; Rouleau, G; Savard, G; Schark, E; Schwarz, S; Schweikhard, L; Stolzenberg, H; Szerypo, J

    1999-01-01

    Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\\delta \\mbox{m} \\approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

  11. High-accuracy mass determination of unstable cesium and barium isotopes

    Science.gov (United States)

    Ames, F.; Audi, G.; Beck, D.; Bollen, G.; de Saint Simon, M.; Jertz, R.; Kluge, H.-J.; Kohl, A.; König, M.; Lunney, D.; Martel, I.; Moore, R. B.; Otto, T.; Patyk, Z.; Raimbault-Hartmann, H.; Rouleau, G.; Savard, G.; Schark, E.; Schwarz, S.; Schweikhard, L.; Stolzenberg, H.; Szerypo, J.; Isolde Collaboration

    1999-05-01

    Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of δm ≈ 13 keV have been obtained. The masses of 123,124,126Ba and 122 mCs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

  12. High-accuracy mass determination of unstable cesium and barium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Ames, F.; Audi, G.; Beck, D.; Bollen, G.; Saint Simon, M. de; Jertz, R.; Kluge, H.-J.; Kohl, A.; Koenig, M.; Lunney, D.; Martel, I.; Moore, R.B.; Otto, T.; Patyk, Z.; Raimbault-Hartmann, H.; Rouleau, G.; Savard, G.; Schark, E.; Schwarz, S.; Schweikhard, L.; Stolzenberg, H.; Szerypo, J

    1999-05-03

    Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of {delta}m {approx}13 keV have been obtained. The masses of {sup 123,124,126}Ba and {sup 122m}Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

  13. Micro Injection Moulding High Accuracy Three-Dimensional Simulations and Process Control

    DEFF Research Database (Denmark)

    Tosello, Guido; Costa, F.S.; Hansen, Hans Nørgaard

    2011-01-01

    Data analysis and simulations of micro‐moulding experiments have been conducted. Micro moulding simulations have been executed by implementing in the software the actual processing conditions. Various aspects of the simulation set‐up have been considered in order to improve the simulation accuracy......, injection pressure profile, moulding mass and flow pattern. The importance of calibrated micro moulding process monitoring for an accurate implementation strategy of the simulation and its validation has been demonstrated. In fact, inconsistencies and uncertainties in the experimental data must be minimized...

  14. Affine-Invariant Geometric Constraints-Based High Accuracy Simultaneous Localization and Mapping

    Directory of Open Access Journals (Sweden)

    Gangchen Hua

    2017-01-01

    Full Text Available In this study we describe a new appearance-based loop-closure detection method for online incremental simultaneous localization and mapping (SLAM using affine-invariant-based geometric constraints. Unlike other pure bag-of-words-based approaches, our proposed method uses geometric constraints as a supplement to improve accuracy. By establishing an affine-invariant hypothesis, the proposed method excludes incorrect visual words and calculates the dispersion of correctly matched visual words to improve the accuracy of the likelihood calculation. In addition, camera’s intrinsic parameters and distortion coefficients are adequate for this method. 3D measuring is not necessary. We use the mechanism of Long-Term Memory and Working Memory (WM to manage the memory. Only a limited size of the WM is used for loop-closure detection; therefore the proposed method is suitable for large-scale real-time SLAM. We tested our method using the CityCenter and Lip6Indoor datasets. Our proposed method results can effectively correct the typical false-positive localization of previous methods, thus gaining better recall ratios and better precision.

  15. Vision-based algorithms for high-accuracy measurements in an industrial bakery

    Science.gov (United States)

    Heleno, Paulo; Davies, Roger; Correia, Bento A. B.; Dinis, Joao

    2002-02-01

    This paper describes the machine vision algorithms developed for VIP3D, a measuring system used in an industrial bakery to monitor the dimensions and weight of loaves of bread (baguettes). The length and perimeter of more than 70 different varieties of baguette are measured with 1-mm accuracy, quickly, reliably and automatically. VIP3D uses a laser triangulation technique to measure the perimeter. The shape of the loaves is approximately cylindrical and the perimeter is defined as the convex hull of a cross-section perpendicular to the baguette axis at mid-length. A camera, mounted obliquely to the measuring plane, captures an image of a laser line projected onto the upper surface of the baguette. Three cameras are used to measure the baguette length, a solution adopted in order to minimize perspective-induced measurement errors. The paper describes in detail the machine vision algorithms developed to perform segmentation of the laser line and subsequent calculation of the perimeter of the baguette. The algorithms used to segment and measure the position of the ends of the baguette, to sub-pixel accuracy, are also described, as are the algorithms used to calibrate the measuring system and compensate for camera-induced image distortion.

  16. Diagnostic accuracy of GPs when using an early-intervention decision support system: a high-fidelity simulation.

    Science.gov (United States)

    Kostopoulou, Olga; Porat, Talya; Corrigan, Derek; Mahmoud, Samhar; Delaney, Brendan C

    2017-03-01

    Observational and experimental studies of the diagnostic task have demonstrated the importance of the first hypotheses that come to mind for accurate diagnosis. A prototype decision support system (DSS) designed to support GPs' first impressions has been integrated with a commercial electronic health record (EHR) system. To evaluate the prototype DSS in a high-fidelity simulation. Within-participant design: 34 GPs consulted with six standardised patients (actors) using their usual EHR. On a different day, GPs used the EHR with the integrated DSS to consult with six other patients, matched for difficulty and counterbalanced. Entering the reason for encounter triggered the DSS, which provided a patient-specific list of potential diagnoses, and supported coding of symptoms during the consultation. At each consultation, GPs recorded their diagnosis and management. At the end, they completed a usability questionnaire. The actors completed a satisfaction questionnaire after each consultation. There was an 8-9% absolute improvement in diagnostic accuracy when the DSS was used. This improvement was significant (odds ratio [OR] 1.41, 95% confidence interval [CI] = 1.13 to 1.77, P<0.01). There was no associated increase of investigations ordered or consultation length. GPs coded significantly more data when using the DSS (mean 12.35 with the DSS versus 1.64 without), and were generally satisfied with its usability. Patient satisfaction ratings were the same for consultations with and without the DSS. The DSS prototype was successfully employed in simulated consultations of high fidelity, with no measurable influences on patient satisfaction. The substantially increased data coding can operate as motivation for future DSS adoption. © British Journal of General Practice 2017.

  17. Comparison of level I land cover classification accuracy for MSS and AVHRR data. [Advanced Very High Resolution Radiometers

    Science.gov (United States)

    Gervin, J. C.; Kerber, A. G.; Witt, R. G.; Lu, Y. C.; Sekhon, R.

    1985-01-01

    The capabilities of the Advanced Very-High-Resolution Radiometer (AVHRR) for land-cover mapping were investigated by comparing the accuracy of land-cover information for the Washington, DC area derived from NOAA-7 AVHRR data with that from Landsat Multispectral Scanner Subsystem (MSS) data. Unsupervised level I land-cover classifications were performed for MSS and AVHRR data sets collected on July 11, 1981. A detailed accuracy assessment was conducted based on ground data delineated on 12 U.S. Geological Survey 7-5 min series topographic maps. These results produced overall land-cover classification accuracies of 71.9 and 76.8 per cent for AVHRR and MSS, respectively. While the accuracies for predominant categories were similar for both sensors, land-cover discrimination for less commonly occurring and/or spatially heterogeneous categories was improved with the MSS data set. The AVHRR, however, performed as well as or better than the MSS in classifying large homogeneous areas. The application of AVHRR data with its lower processing cost and more frequent worldwide coverage appears promising for regional land-cover mapping.

  18. a Method to Achieve Large Volume, High Accuracy Photogrammetric Measurements Through the Use of AN Actively Deformable Sensor Mounting Platform

    Science.gov (United States)

    Sargeant, B.; Robson, S.; Szigeti, E.; Richardson, P.; El-Nounu, A.; Rafla, M.

    2016-06-01

    When using any optical measurement system one important factor to consider is the placement of the sensors in relation to the workpiece being measured. When making decisions on sensor placement compromises are necessary in selecting the best placement based on the shape and size of the object of interest and the desired resolution and accuracy. One such compromise is in the distance the sensors are placed from the measurement surface, where a smaller distance gives a higher spatial resolution and local accuracy and a greater distance reduces the number of measurements necessary to cover a large area reducing the build-up of errors between measurements and increasing global accuracy. This paper proposes a photogrammetric approach whereby a number of sensors on a continuously flexible mobile platform are used to obtain local measurements while the position of the sensors is determined by a 6DoF tracking solution and the results combined to give a single set of measurement data within a continuous global coordinate system. The ability of this approach to achieve both high accuracy measurement and give results over a large volume is then tested and areas of weakness to be improved upon are identified.

  19. The design of a high-efficiency neutron counter for waste drums to provide optimized sensitivity for plutonium assay

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, H.O.; Beddingfield, D.H.; Pickrell, M.M. [Los Alamos National Lab., NM (United States)] [and others

    1997-11-01

    An advanced passive neutron counter has been designed to improve the accuracy and sensitivity for the nondestructive assay of plutonium in scrap and waste containers. The High-Efficiency Neutron Counter (HENC) was developed under a Cooperative Research Development Agreement between the Los Alamos National Laboratory and Canberra Industries. The primary goal of the development was to produce a passive assay system for 200-L drums that has detectability limits and multiplicity counting features that are superior to previous systems. A detectability limit figure of merit (FOM) was defined that included the detector efficiency, the neutron die-away time, and the detector`s active volume and density that determine the cosmic-ray background. Monte Carlo neutron calculations were performed to determine the parameters to provide an optimum FOM. The system includes the {sup 252}Cf {open_quotes}add-a-source{close_quotes} feature to improve the accuracy as well as statistical filters to reduce the cosmic-ray spallation neutron background. The final decision gave an efficiency of 32% for plutonium with a detector {sup 3}He tube volume that is significantly smaller than for previous high-efficiency systems for 200-L drums. Because of the high efficiency of the HENC, we have incorporated neutron multiplicity counting for matrix corrections for those cases where the plutonium is localized in nonuniform hydrogenous materials. The paper describes the design and performance testing of the advanced system. 5 refs., 8 figs., 3 tabs.

  20. Accuracy of W' Recovery Kinetics in High Performance Cyclists - Modelling Intermittent Work Capacity.

    Science.gov (United States)

    Bartram, Jason C; Thewlis, Dominic; Martin, David T; Norton, Kevin I

    2017-10-16

    With knowledge of an individual's critical power (CP) and W' the SKIBA 2 model provides a framework with which to track W' balance during intermittent high intensity work bouts. There are fears the time constant controlling the recovery rate of W' (τW') may require refinement to enable effective use in an elite population. Four elite endurance cyclists completed an array of intermittent exercise protocols to volitional exhaustion. Each protocol lasted approximately 3.5-6 minutes and featured a range of recovery intensities, set in relation to athlete's CPs (DCP). Using the framework of the SKIBA 2 model, the τW' values were modified for each protocol to achieve an accurate W' at volitional exhaustion. Modified τW' values were compared to equivalent SKIBA 2 τW' values to assess the difference in recovery rates for this population. Plotting modified τW' values against DCP showed the adjusted relationship between work-rate and recovery-rate. Comparing modified τW' values against the SKIBA 2 τW' values showed a negative bias of 112±46s (mean±95%CL), suggesting athlete's recovered W' faster than predicted by SKIBA 2 (p=0.0001). The modified τW' to DCP relationship was best described by a power function: τW'=2287.2∗DCP(-0.688)(R(2) = 0.433). The current SKIBA 2 model is not appropriate for use in elite cyclists as it under predicts the recovery rate of W'. The modified τW' equation presented will require validation, but appears more appropriate for high performance athletes. Individual τW' relationships may be necessary in order to maximise the model's validity.

  1. Multiplex ligation-dependent probe amplification assay identifies additional copy number changes compared with R-band karyotype and provide more accuracy prognostic information in myelodysplastic syndromes.

    Science.gov (United States)

    Wang, Jingya; Ai, Xiaofei; Qin, Tiejun; Xu, Zefeng; Zhang, Yue; Liu, Jinqin; Li, Bing; Fang, Liwei; Zhang, Hongli; Pan, Lijuan; Hu, Naibo; Qu, Shiqiang; Cai, Wenyu; Ru, Kun; Jia, Yujiao; Huang, Gang; Xiao, Zhijian

    2017-01-03

    Cytogenetic analysis provides important diagnostic and prognostic information for patients with Myelodysplastic syndromes (MDS) and plays an essential role in the International Prognostic Scoring System (IPSS) and the revised International Prognostic Scoring System (IPSS-R). Multiplex ligation-dependent probe amplification (MLPA) assay is a recently developed technique to identify targeted cytogenetic aberrations in MDS patients. In the present study, we evaluated the results obtained using an MLPA assay in 437 patients with MDS to determine the efficacy of MLPA analysis. Using R-banding karyotyping, 45% (197/437) of MDS patients had chromosomal abnormalities, whereas MLPA analysis detected that 35% (153/437) of MDS cases contained at least one copy-number variations (CNVs) .2/5 individuals (40%) with R-band karyotype failures had trisomy 8 detected using only MLPA. Clonal cytogenetic abnormalities were detected in 20/235 (8.5%) MDS patients with a normal R-band karyotype, and 12/20 (60%) of those patients were reclassified into a higher-risk IPSS-R prognostic category. When sequencing and cytogenetics were combined, the fraction of patients with MDS-related oncogenic lesions increased to 87.3% (233/267 cases). MLPA analysis determined that the median OS of patients with a normal karyotype (n=218) was 65 months compared with 27 months in cases with an aberrant karyotype (P=0.002) in 240 patients with normal or failed karyotypes by R-banding karyotyping. The high-resolution MPLA assay is an efficient and reliable method that can be used in conjunction with R-band karyotyping to detect chromosomal abnormalities in patients with suspected MDS. MLPA may also provide more accurate prognostic information.

  2. Multiplex ligation-dependent probe amplification assay identifies additional copy number changes compared with R-band karyotype and provide more accuracy prognostic information in myelodysplastic syndromes

    Science.gov (United States)

    Xu, Zefeng; Zhang, Yue; Liu, Jinqin; Li, Bing; Fang, Liwei; Zhang, Hongli; Pan, Lijuan; Hu, Naibo; Qu, Shiqiang; Cai, Wenyu; Ru, Kun; Jia, Yujiao; Huang, Gang; Xiao, Zhijian

    2017-01-01

    Cytogenetic analysis provides important diagnostic and prognostic information for patients with Myelodysplastic syndromes (MDS) and plays an essential role in the International Prognostic Scoring System (IPSS) and the revised International Prognostic Scoring System (IPSS-R). Multiplex ligation-dependent probe amplification (MLPA) assay is a recently developed technique to identify targeted cytogenetic aberrations in MDS patients. In the present study, we evaluated the results obtained using an MLPA assay in 437 patients with MDS to determine the efficacy of MLPA analysis. Using R-banding karyotyping, 45% (197/437) of MDS patients had chromosomal abnormalities, whereas MLPA analysis detected that 35% (153/437) of MDS cases contained at least one copy-number variations (CNVs) .2/5 individuals (40%) with R-band karyotype failures had trisomy 8 detected using only MLPA. Clonal cytogenetic abnormalities were detected in 20/235 (8.5%) MDS patients with a normal R-band karyotype, and 12/20 (60%) of those patients were reclassified into a higher-risk IPSS-R prognostic category. When sequencing and cytogenetics were combined, the fraction of patients with MDS-related oncogenic lesions increased to 87.3% (233/267 cases). MLPA analysis determined that the median OS of patients with a normal karyotype (n=218) was 65 months compared with 27 months in cases with an aberrant karyotype (P=0.002) in 240 patients with normal or failed karyotypes by R-banding karyotyping. The high-resolution MPLA assay is an efficient and reliable method that can be used in conjunction with R-band karyotyping to detect chromosomal abnormalities in patients with suspected MDS. MLPA may also provide more accurate prognostic information. PMID:27906673

  3. Provider Knowledge of Trivalent Inactivated and High-Dose Influenza Vaccines

    OpenAIRE

    Tewell, Chad; Wright, Patty W.; Talbot, H. Keipp

    2014-01-01

    The objective of this study was to assess provider knowledge about trivalent inactivated and high dose influenza vaccines. Hence, a 20 item survey was distributed to providers within the Internal Medicine department at an urban academic medical center.

  4. Evaluation of Heart Rate Assessment Timing, Communication, Accuracy, and Clinical Decision-Making during High Fidelity Simulation of Neonatal Resuscitation

    Directory of Open Access Journals (Sweden)

    Win Boon

    2014-01-01

    Full Text Available Objective. Accurate heart rate (HR determination during neonatal resuscitation (NR informs subsequent NR actions. This study’s objective was to evaluate HR determination timeliness, communication, and accuracy during high fidelity NR simulations that house officers completed during neonatal intensive care unit (NICU rotations. Methods. In 2010, house officers in NICU rotations completed high fidelity NR simulation. We reviewed 80 house officers’ videotaped performance on their initial high fidelity simulation session, prior to training and performance debriefing. We calculated the proportion of cases congruent with NR guidelines, using chi square analysis to evaluate performance across HR ranges relevant to NR decision-making: <60, 60–99, and ≥100 beats per minute (bpm. Results. 87% used umbilical cord palpation, 57% initiated HR assessment within 30 seconds, 70% were accurate, and 74% were communicated appropriately. HR determination accuracy varied significantly across HR ranges, with 87%, 57%, and 68% for HR <60, 60–99, and ≥100 bpm, respectively (P<0.001. Conclusions. Timeliness, communication, and accuracy of house officers’ HR determination are suboptimal, particularly for HR 60–100 bpm, which might lead to inappropriate decision-making and NR care. Training implications include emphasizing more accurate HR determination methods, better communication, and improved HR interpretation during NR.

  5. Accuracy and repeatability positioning of high-performancel athe for non-circular turning

    Science.gov (United States)

    Majda, Paweł; Powałka, Bartosz

    2017-11-01

    This paper presents research on the accuracy and repeatability of CNC axis positioning in an innovative lathe with an additional Xs axis. This axis is used to perform movements synchronized with the angular position of the main drive, i.e. the spindle, and with the axial feed along the Z axis. This enables the one-pass turning of non-circular surfaces, rope and trapezoidal threads, as well as the surfaces of rotary tools such as a gear cutting hob, etc. The paper presents and discusses the interpretation of results and the calibration effects of positioning errors in the lathe's numerical control system. Finally, it shows the geometric characteristics of the rope thread turned at various spindle speeds, including before and after-correction of the positioning error of the Xs axis.

  6. Accuracy and repeatability positioning of high-performancel athe for non-circular turning

    Directory of Open Access Journals (Sweden)

    Majda Paweł

    2017-11-01

    Full Text Available This paper presents research on the accuracy and repeatability of CNC axis positioning in an innovative lathe with an additional Xs axis. This axis is used to perform movements synchronized with the angular position of the main drive, i.e. the spindle, and with the axial feed along the Z axis. This enables the one-pass turning of non-circular surfaces, rope and trapezoidal threads, as well as the surfaces of rotary tools such as a gear cutting hob, etc. The paper presents and discusses the interpretation of results and the calibration effects of positioning errors in the lathe’s numerical control system. Finally, it shows the geometric characteristics of the rope thread turned at various spindle speeds, including before and after-correction of the positioning error of the Xs axis.

  7. High-accuracy identification of incident HIV-1 infections using a sequence clustering based diversity measure.

    Directory of Open Access Journals (Sweden)

    Xia-Yu Xia

    Full Text Available Accurate estimates of HIV-1 incidence are essential for monitoring epidemic trends and evaluating intervention efforts. However, the long asymptomatic stage of HIV-1 infection makes it difficult to effectively distinguish incident infections from chronic ones. Current incidence assays based on serology or viral sequence diversity are both still lacking in accuracy. In the present work, a sequence clustering based diversity (SCBD assay was devised by utilizing the fact that viral sequences derived from each transmitted/founder (T/F strain tend to cluster together at early stage, and that only the intra-cluster diversity is correlated with the time since HIV-1 infection. The dot-matrix pairwise alignment was used to eliminate the disproportional impact of insertion/deletions (indels and recombination events, and so was the proportion of clusterable sequences (Pc as an index to identify late chronic infections with declined viral genetic diversity. Tested on a dataset containing 398 incident and 163 chronic infection cases collected from the Los Alamos HIV database (last modified 2/8/2012, our SCBD method achieved 99.5% sensitivity and 98.8% specificity, with an overall accuracy of 99.3%. Further analysis and evaluation also suggested its performance was not affected by host factors such as the viral subtypes and transmission routes. The SCBD method demonstrated the potential of sequencing based techniques to become useful for identifying incident infections. Its use may be most advantageous for settings with low to moderate incidence relative to available resources. The online service is available at http://www.bioinfo.tsinghua.edu.cn:8080/SCBD/index.jsp.

  8. High-accuracy identification of incident HIV-1 infections using a sequence clustering based diversity measure.

    Science.gov (United States)

    Xia, Xia-Yu; Ge, Meng; Hsi, Jenny H; He, Xiang; Ruan, Yu-Hua; Wang, Zhi-Xin; Shao, Yi-Ming; Pan, Xian-Ming

    2014-01-01

    Accurate estimates of HIV-1 incidence are essential for monitoring epidemic trends and evaluating intervention efforts. However, the long asymptomatic stage of HIV-1 infection makes it difficult to effectively distinguish incident infections from chronic ones. Current incidence assays based on serology or viral sequence diversity are both still lacking in accuracy. In the present work, a sequence clustering based diversity (SCBD) assay was devised by utilizing the fact that viral sequences derived from each transmitted/founder (T/F) strain tend to cluster together at early stage, and that only the intra-cluster diversity is correlated with the time since HIV-1 infection. The dot-matrix pairwise alignment was used to eliminate the disproportional impact of insertion/deletions (indels) and recombination events, and so was the proportion of clusterable sequences (Pc) as an index to identify late chronic infections with declined viral genetic diversity. Tested on a dataset containing 398 incident and 163 chronic infection cases collected from the Los Alamos HIV database (last modified 2/8/2012), our SCBD method achieved 99.5% sensitivity and 98.8% specificity, with an overall accuracy of 99.3%. Further analysis and evaluation also suggested its performance was not affected by host factors such as the viral subtypes and transmission routes. The SCBD method demonstrated the potential of sequencing based techniques to become useful for identifying incident infections. Its use may be most advantageous for settings with low to moderate incidence relative to available resources. The online service is available at http://www.bioinfo.tsinghua.edu.cn:8080/SCBD/index.jsp.

  9. Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS).

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    Electron-excited X-ray microanalysis performed in the scanning electron microscope with energy-dispersive X-ray spectrometry (EDS) is a core technique for characterization of the microstructure of materials. The recent advances in EDS performance with the silicon drift detector (SDD) enable accuracy and precision equivalent to that of the high spectral resolution wavelength-dispersive spectrometer employed on the electron probe microanalyzer platform. SDD-EDS throughput, resolution, and stability provide practical operating conditions for measurement of high-count spectra that form the basis for peak fitting procedures that recover the characteristic peak intensities even for elemental combination where severe peak overlaps occur, such PbS, MoS2, BaTiO3, SrWO4, and WSi2. Accurate analyses are also demonstrated for interferences involving large concentration ratios: a major constituent on a minor constituent (Ba at 0.4299 mass fraction on Ti at 0.0180) and a major constituent on a trace constituent (Ba at 0.2194 on Ce at 0.00407; Si at 0.1145 on Ta at 0.0041). Accurate analyses of low atomic number elements, C, N, O, and F, are demonstrated. Measurement of trace constituents with limits of detection below 0.001 mass fraction (1000 ppm) is possible within a practical measurement time of 500 s.

  10. Fast converging with high accuracy estimates of satellite attitude and orbit based on magnetometer augmented with gyro, star sensor and GPS via extended Kalman filter

    Directory of Open Access Journals (Sweden)

    Tamer Mekky Ahmed Habib

    2011-12-01

    Full Text Available The primary goal of this work is to extend the work done in, Tamer (2009, to provide high accuracy satellite attitude and orbit estimates needed for imaging purposes and also before execution of spacecraft orbital maneuvers for the next Egyptian scientific satellite. The problem of coarse satellite attitude and orbit estimation based on magnetometer measurements has been treated in the literature. The current research expands the field of application from coarse and slow converging estimates to accurate and fast converging attitude and orbit estimates within 0.1°, and 10 m for attitude angles and spacecraft location respectively (1-σ. The magnetometer is used for both spacecraft attitude and orbit estimation, aided with gyro to provide angular velocity measurements, star sensor to provide attitude quaternion, and GPS receiver to provide spacecraft location. The spacecraft under consideration is subject to solar radiation pressure forces and moments, aerodynamics forces and moments, earth’s oblateness till the fourth order (i.e. J4, gravity gradient moments, and residual magnetic dipole moments. The estimation algorithm developed is powerful enough to converge quickly (actually within 10 s despite very large initial estimation errors with sufficiently high accuracy estimates.

  11. A smartphone imaging-based label-free and dual-wavelength fluorescent biosensor with high sensitivity and accuracy.

    Science.gov (United States)

    Lee, Won-Il; Shrivastava, Sajal; Duy, Le-Thai; Yeong Kim, Bo; Son, Young-Min; Lee, Nae-Eung

    2017-08-15

    The accuracy of a bioassay based on smartphone-integrated fluorescent biosensors has been limited due to the occurrence of false signals from non-specific reactions as well as a high background and low signal-to-noise ratios for complementary metal oxide semiconductor image sensors. To overcome this problem, we demonstrate dual-wavelength fluorescent detection of biomolecules with high accuracy. Fluorescent intensity can be quantified using dual wavelengths simultaneously, where one decreases and the other increases, as the target analytes bind to the split capture and detection aptamer probes. To do this, we performed smartphone imaging-based fluorescence microscopy using a microarray platform on a substrate with metal-enhanced fluorescence (MEF) using Ag film and Al2O3 nano-spacer. The results showed that the sensitivity and specificity of the dual-wavelength fluorescent quantitative assay for the target biomolecule 17-β-estradiol in water were significantly increased through the elimination of false signals. The detection limit was 1pg/mL and the area under the receiver operating characteristic curve of the proposed assay (0.922) was comparable to that of an enzyme-linked immunosorbent assay (0.956) from statistical accuracy tests using spiked wastewater samples. This novel method has great potential as an accurate point-of-care testing technology based on mobile platforms for clinical diagnostics and environmental monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Radiometric inter-sensor cross-calibration uncertainty using a traceable high accuracy reference hyperspectral imager

    Science.gov (United States)

    Gorroño, Javier; Banks, Andrew C.; Fox, Nigel P.; Underwood, Craig

    2017-08-01

    Optical earth observation (EO) satellite sensors generally suffer from drifts and biases relative to their pre-launch calibration, caused by launch and/or time in the space environment. This places a severe limitation on the fundamental reliability and accuracy that can be assigned to satellite derived information, and is particularly critical for long time base studies for climate change and enabling interoperability and Analysis Ready Data. The proposed TRUTHS (Traceable Radiometry Underpinning Terrestrial and Helio-Studies) mission is explicitly designed to address this issue through re-calibrating itself directly to a primary standard of the international system of units (SI) in-orbit and then through the extension of this SI-traceability to other sensors through in-flight cross-calibration using a selection of Committee on Earth Observation Satellites (CEOS) recommended test sites. Where the characteristics of the sensor under test allows, this will result in a significant improvement in accuracy. This paper describes a set of tools, algorithms and methodologies that have been developed and used in order to estimate the radiometric uncertainty achievable for an indicative target sensor through in-flight cross-calibration using a well-calibrated hyperspectral SI-traceable reference sensor with observational characteristics such as TRUTHS. In this study, Multi-Spectral Imager (MSI) of Sentinel-2 and Landsat-8 Operational Land Imager (OLI) is evaluated as an example, however the analysis is readily translatable to larger-footprint sensors such as Sentinel-3 Ocean and Land Colour Instrument (OLCI) and Visible Infrared Imaging Radiometer Suite (VIIRS). This study considers the criticality of the instrumental and observational characteristics on pixel level reflectance factors, within a defined spatial region of interest (ROI) within the target site. It quantifies the main uncertainty contributors in the spectral, spatial, and temporal domains. The resultant tool

  13. The high accuracy data processing system of laser interferometry signals based on MSP430

    Science.gov (United States)

    Qi, Yong-yue; Lin, Yu-chi; Zhao, Mei-rong

    2009-07-01

    Generally speaking there are two orthogonal signals used in single-frequency laser interferometer for differentiating direction and electronic subdivision. However there usually exist three errors with the interferential signals: zero offsets error, unequal amplitude error and quadrature phase shift error. These three errors have a serious impact on subdivision precision. Based on Heydemann error compensation algorithm, it is proposed to achieve compensation of the three errors. Due to complicated operation of the Heydemann mode, a improved arithmetic is advanced to decrease the calculating time effectively in accordance with the special characteristic that only one item of data will be changed in each fitting algorithm operation. Then a real-time and dynamic compensatory circuit is designed. Taking microchip MSP430 as the core of hardware system, two input signals with the three errors are turned into digital quantity by the AD7862. After data processing in line with improved arithmetic, two ideal signals without errors are output by the AD7225. At the same time two original signals are turned into relevant square wave and imported to the differentiating direction circuit. The impulse exported from the distinguishing direction circuit is counted by the timer of the microchip. According to the number of the pulse and the soft subdivision the final result is showed by LED. The arithmetic and the circuit are adopted to test the capability of a laser interferometer with 8 times optical path difference and the measuring accuracy of 12-14nm is achieved.

  14. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Shaohui Foong

    2016-08-01

    Full Text Available In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs. Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison.

  15. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis.

    Science.gov (United States)

    Foong, Shaohui; Sun, Zhenglong

    2016-08-12

    In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA) is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs). Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison.

  16. Accuracy of device-specific 2D and 3D image distortion correction algorithms for magnetic resonance imaging of the head provided by a manufacturer

    Energy Technology Data Exchange (ETDEWEB)

    Karger, Christian P [German Cancer Research Center (DKFZ), Department of Medical Physics in Radiation Oncology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Hoess, Angelika [German Cancer Research Center (DKFZ), Department of Medical Physics in Radiation Oncology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bendl, Rolf [German Cancer Research Center (DKFZ), Department of Medical Physics in Radiation Oncology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Canda, Valer [Siemens Medical Solutions, MRE W, Karl-Schall-Str. 4, 91052 Erlangen (Germany); Schad, Lothar [German Cancer Research Center (DKFZ), Department of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)

    2006-06-21

    For the application of magnetic resonance imaging (MRI) in precision radiotherapy, image distortions must be reduced to a minimum to maintain geometrical accuracy. Recently, two-dimensional (2D) and three-dimensional (3D) algorithms for MRI-device-specific distortion corrections were developed by the manufacturers of MRI devices. A previously developed phantom (Karger C P et al 2003 Phys. Med. Biol. 48 211-21) was used to quantify and assess the size of geometrical image distortions before and after application of the 2D and 3D correction algorithm in the head region. Four different types of MRI devices with different gradient systems were measured. For comparison, measurements were also performed with two computed tomography (CT) devices. Mean distortions of up to 4.6{+-}1.4 mm (maximum: 5.8 mm) were found prior to the correction. After the correction, the mean distortions were well below 2.0 mm in most cases. Distortions in the CT images were below or equal to 1.0 mm on average. Generally, the 3D algorithm produced comparable or better results than the 2D algorithm. The remaining distortions after the correction appear to be acceptable for fractionated radiotherapy. (note)

  17. Accuracy assessment of NOAA gridded daily reference evapotranspiration for the Texas High Plains

    Science.gov (United States)

    The National Oceanic and Atmospheric Administration (NOAA) provides daily reference evapotranspiration (ETref) maps for the contiguous United States using climatic data from North American Land Data Assimilation System (NLDAS). This data provides large-scale spatial representation of ETref, which i...

  18. Accuracy assessment of NOAA's daily reference evapotranspiration maps for the Texas High Plains

    Science.gov (United States)

    The National Oceanic and Atmospheric Administration (NOAA) provides daily reference ET for the continental U.S. using climatic data from North American Land Data Assimilation System (NLDAS). This data provides large scale spatial representation for reference ET, which is essential for regional scal...

  19. ISPA - a high accuracy X-ray and gamma camera Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    ISPA offers ... Ten times better resolution than Anger cameras High efficiency single gamma counting Noise reduction by sensitivity to gamma energy ...for Single Photon Emission Computed Tomography (SPECT)

  20. High accuracy and precision micro injection moulding of thermoplastic elastomers micro ring production

    DEFF Research Database (Denmark)

    Calaon, Matteo; Tosello, Guido; Elsborg, René

    2016-01-01

    /product monitoring and metrology. The study represent a new concept yet to be developed with great potential for high precision mass-manufacturing of highly functional 3D multi-material (i.e. including metal/soft polymer) micro components. The activities related to HINMICO project objectives proves the importance...

  1. Snow cover volumes dynamic monitoring during melting season using high topographic accuracy approach for a Lebanese high plateau witness sinkhole

    Science.gov (United States)

    Abou Chakra, Charbel; Somma, Janine; Elali, Taha; Drapeau, Laurent

    2017-04-01

    Climate change and its negative impact on water resource is well described. For countries like Lebanon, undergoing major population's rise and already decreasing precipitations issues, effective water resources management is crucial. Their continuous and systematic monitoring overs long period of time is therefore an important activity to investigate drought risk scenarios for the Lebanese territory. Snow cover on Lebanese mountains is the most important water resources reserve. Consequently, systematic observation of snow cover dynamic plays a major role in order to support hydrologic research with accurate data on snow cover volumes over the melting season. For the last 20 years few studies have been conducted for Lebanese snow cover. They were focusing on estimating the snow cover surface using remote sensing and terrestrial measurement without obtaining accurate maps for the sampled locations. Indeed, estimations of both snow cover area and volumes are difficult due to snow accumulation very high variability and Lebanese mountains chains slopes topographic heterogeneity. Therefore, the snow cover relief measurement in its three-dimensional aspect and its Digital Elevation Model computation is essential to estimate snow cover volume. Despite the need to cover the all lebanese territory, we favored experimental terrestrial topographic site approaches due to high resolution satellite imagery cost, its limited accessibility and its acquisition restrictions. It is also most challenging to modelise snow cover at national scale. We therefore, selected a representative witness sinkhole located at Ouyoun el Siman to undertake systematic and continuous observations based on topographic approach using a total station. After four years of continuous observations, we acknowledged the relation between snow melt rate, date of total melting and neighboring springs discharges. Consequently, we are able to forecast, early in the season, dates of total snowmelt and springs low

  2. DURA-Peel, DURACON-Based Removable High Accuracy IR Thermography Coatings Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Fiber reinforced composite materials are used extensively in aerospace applications due to their high stiffness and strength to weight ratio, and superior thermal,...

  3. Sensitivity and accuracy of high-throughput metabarcoding methods for early detection of invasive fish species

    Science.gov (United States)

    For early detection biomonitoring of aquatic invasive species, sensitivity to rare individuals and accurate, high-resolution taxonomic classification are critical to minimize detection errors. Given the great expense and effort associated with morphological identification of many...

  4. Conceptual and practical bases for the high accuracy of machine learning interatomic potentials: Application to elemental titanium

    Science.gov (United States)

    Takahashi, Akira; Seko, Atsuto; Tanaka, Isao

    2017-11-01

    Machine learning interatomic potentials (MLIPs) based on a large data set obtained by density functional theory calculation have been developed recently. This study gives both conceptual and practical bases for the high accuracy of MLIPs, although MLIPs have been considered to be simply an accurate black-box description of atomic energy. We also construct the most accurate MLIP of elemental Ti ever reported using a linearized MLIP framework and many angular-dependent descriptors, which also corresponds to a generalization of the modified embedded atom method potential.

  5. Interethnic differences in the accuracy of anthropometric indicators of obesity in screening for high risk of coronary heart disease

    Science.gov (United States)

    Herrera, VM; Casas, JP; Miranda, JJ; Perel, P; Pichardo, R; González, A; Sanchez, JR; Ferreccio, C; Aguilera, X; Silva, E; Oróstegui, M; Gómez, LF; Chirinos, JA; Medina-Lezama, J; Pérez, CM; Suárez, E; Ortiz, AP; Rosero, L; Schapochnik, N; Ortiz, Z; Ferrante, D; Diaz, M; Bautista, LE

    2009-01-01

    Background Cut points for defining obesity have been derived from mortality data among Whites from Europe and the United States and their accuracy to screen for high risk of coronary heart disease (CHD) in other ethnic groups has been questioned. Objective To compare the accuracy and to define ethnic and gender-specific optimal cut points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) when they are used in screening for high risk of CHD in the Latin-American and the US populations. Methods We estimated the accuracy and optimal cut points for BMI, WC and WHR to screen for CHD risk in Latin Americans (n=18 976), non-Hispanic Whites (Whites; n=8956), non-Hispanic Blacks (Blacks; n=5205) and Hispanics (n=5803). High risk of CHD was defined as a 10-year risk ≥20% (Framingham equation). The area under the receiver operator characteristic curve (AUC) and the misclassification-cost term were used to assess accuracy and to identify optimal cut points. Results WHR had the highest AUC in all ethnic groups (from 0.75 to 0.82) and BMI had the lowest (from 0.50 to 0.59). Optimal cut point for BMI was similar across ethnic/gender groups (27 kg/m2). In women, cut points for WC (94 cm) and WHR (0.91) were consistent by ethnicity. In men, cut points for WC and WHR varied significantly with ethnicity: from 91 cm in Latin Americans to 102 cm in Whites, and from 0.94 in Latin Americans to 0.99 in Hispanics, respectively. Conclusion WHR is the most accurate anthropometric indicator to screen for high risk of CHD, whereas BMI is almost uninformative. The same BMI cut point should be used in all men and women. Unique cut points for WC and WHR should be used in all women, but ethnic-specific cut points seem warranted among men. PMID:19238159

  6. A high-accuracy consensus map of yeast protein complexes reveals modular nature of gene essentiality

    Directory of Open Access Journals (Sweden)

    Marcotte Edward M

    2007-07-01

    Full Text Available Abstract Background Identifying all protein complexes in an organism is a major goal of systems biology. In the past 18 months, the results of two genome-scale tandem affinity purification-mass spectrometry (TAP-MS assays in yeast have been published, along with corresponding complex maps. For most complexes, the published data sets were surprisingly uncorrelated. It is therefore useful to consider the raw data from each study and generate an accurate complex map from a high-confidence data set that integrates the results of these and earlier assays. Results Using an unsupervised probabilistic scoring scheme, we assigned a confidence score to each interaction in the matrix-model interpretation of the large-scale yeast mass-spectrometry data sets. The scoring metric proved more accurate than the filtering schemes used in the original data sets. We then took a high-confidence subset of these interactions and derived a set of complexes using MCL. The complexes show high correlation with existing annotations. Hierarchical organization of some protein complexes is evident from inter-complex interactions. Conclusion We demonstrate that our scoring method can generate an integrated high-confidence subset of observed matrix-model interactions, which we subsequently used to derive an accurate map of yeast complexes. Our results indicate that essentiality is a product of the protein complex rather than the individual protein, and that we have achieved near saturation of the yeast high-abundance, rich-media-expressed "complex-ome."

  7. Self-powered microneedle-based biosensors for pain-free high-accuracy measurement of glycaemia in interstitial fluid.

    Science.gov (United States)

    Strambini, L M; Longo, A; Scarano, S; Prescimone, T; Palchetti, I; Minunni, M; Giannessi, D; Barillaro, G

    2015-04-15

    In this work a novel self-powered microneedle-based transdermal biosensor for pain-free high-accuracy real-time measurement of glycaemia in interstitial fluid (ISF) is reported. The proposed transdermal biosensor makes use of an array of silicon-dioxide hollow microneedles that are about one order of magnitude both smaller (borehole down to 4µm) and more densely-packed (up to 1×10(6)needles/cm(2)) than state-of-the-art microneedles used for biosensing so far. This allows self-powered (i.e. pump-free) uptake of ISF to be carried out with high efficacy and reliability in a few seconds (uptake rate up to 1µl/s) by exploiting capillarity in the microneedles. By coupling the microneedles operating under capillary-action with an enzymatic glucose biosensor integrated on the back-side of the needle-chip, glucose measurements are performed with high accuracy (±20% of the actual glucose level for 96% of measures) and reproducibility (coefficient of variation 8.56%) in real-time (30s) over the range 0-630mg/dl, thus significantly improving microneedle-based biosensor performance with respect to the state-of-the-art. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. High Accuracy Investigation of Microwave Absorption in Polymer Electrical Components on Motherboard of Computers

    Science.gov (United States)

    Dašić, P.; Hutanu, C.; Jevremović, V.; Dobra, R.; Risteiu, M.; Ileana, I.

    2017-06-01

    Electronic operating at high frequencies can have problems with emission of high frequency noise. Once put inside an enclosure, the energy will add in phase at certain frequencies to cause resonances which will hinder the performance of the device. These absorbers are based upon open celled foam impregnated with a carbon coating. It is quite possible that in the near future, microprocessors would be to work on a frequency located in 5 to 10 GHz. In these circumstances it is useful to know how and how much of the electromagnetic field emitted by a microprocessor, it is absorbed by the circuit elements in the immediate vicinity of the microprocessor. The aim of this contribution is to demonstrate throughout high-level experimental analysis how the main electric parameters of polymer materials, which build the printed circuits and the one of electric capacitors and resistors, depend on the frequencies on which they work from the microwave range.

  9. High-accuracy detector calibration at the PTB four-crystal monochromator beamline

    CERN Document Server

    Krumrey, M

    2001-01-01

    A four-crystal monochromator beamline has been installed by the Physikalisch-Technische Bundesanstalt at a bending magnet of the electron storage ring BESSY II. The monochromatic radiation with very high spectral purity and high spectral resolution in the photon energy range from 1.75 to 10 keV is used to calibrate detectors by comparison to a cryogenic electrical substitution radiometer as primary detector standard with relative uncertainties well below 1%. This is one order of magnitude better than all calibrations of non-energy-dispersive detectors in this spectral range previously performed. The beamline is also used for the characterization of optical components.

  10. High Accuracy Tracking of Space-Borne Non-Cooperative Targets

    DEFF Research Database (Denmark)

    Pedersen, David Arge Klevang

    the surface and to enhance the PIXL instrument's capabilities with highly accurate distance measurements. Optical observations of planetary bodies and satellites are utilized to determine the inertial position of a spacecraft. A software module is developed, tested and verified by both ground based and in...

  11. Isolating Flow-field Discontinuities while Preserving Monotonicity and High-order Accuracy on Cartesian Meshes

    Science.gov (United States)

    2017-01-09

    19b. TELEPHONE NUMBER (Include area code) 01/09/2017 Briefing Charts 01 January 2017 - 31 January 2017 Isolating Flow -field Discontinuities while...Unclassified Unclassified Unclassified SAR 18 V. Sanakaran N/A Isolating Flow -field Discontinuities while Preserving Monotonicity and High-order

  12. Lower confidence bounds for prediction accuracy in high dimensions via AROHIL Monte Carlo.

    Science.gov (United States)

    Dobbin, Kevin K; Cooke, Stephanie

    2011-11-15

    Implementation and development of statistical methods for high-dimensional data often require high-dimensional Monte Carlo simulations. Simulations are used to assess performance, evaluate robustness, and in some cases for implementation of algorithms. But simulation in high dimensions is often very complex, cumbersome and slow. As a result, performance evaluations are often limited, robustness minimally investigated and dissemination impeded by implementation challenges. This article presents a method for converting complex, slow high-dimensional Monte Carlo simulations into simpler, faster lower dimensional simulations. We implement the method by converting a previous Monte Carlo algorithm into this novel Monte Carlo, which we call AROHIL Monte Carlo. AROHIL Monte Carlo is shown to exactly or closely match pure Monte Carlo results in a number of examples. It is shown that computing time can be reduced by several orders of magnitude. The confidence bound method implemented using AROHIL outperforms the pure Monte Carlo method. Finally, the utility of the method is shown by application to a number of real microarray datasets.

  13. Context, accuracy, and level of inclusion of nature of science concepts in current high school physics textbooks

    Science.gov (United States)

    Alshamrani, Saeed Mohammed

    To improve K-12 students' images of the nature of science (NOS) through science textbooks, two issues must be addressed: (a) the level of NOS that ought to be included in science textbooks and (b) the treatment of this level in those textbooks. Science educators achieved a consensus level of agreement regarding what NOS aspects should be taught for K-12 science learners; however, there is a need for more clarification regarding the actual treatment of NOS in science textbooks. The purpose of this study is to investigate the NOS inclusion in high school physics textbooks. To be specific, this study examines the included NOS aspects, the frequency of NOS inclusion, the contexts exist for NOS inclusion, and the accuracy of NOS inclusion. This study utilized 12 science education studies to develop the Master Aspects of Nature of Science [MA-NOS] which includes 12 NOS aspects that ought to be included in K-12 science curriculum. The analyzed textbooks in this study are seven textbooks identified by The American Institute of Physics as the most widely used high school physics textbooks in the United States in 2005. These textbooks were used in teaching five academic levels: (a) Regular First-Year Physics, (b) Physics for Non-Science Students, (c) Honors Physics, (d) AP-B Physics, and (e) AP-C Physics. The researcher selected exclusively physics textbooks because physics is his main interest. To facilitate the content analysis of the selected textbooks, the study developed The Collection Data Coding Guide which includes six parts describing the MA-NOS aspects and the process of identifying and collecting data. For each NOS aspect, a description and one or more selected ideal indicators were provided to facilitate data collecting and judging the accuracy of NOS inclusion. This coding guide was reviewed for its content validity by two science educators who specialize in NOS. However, two types of reliability were conducted to identify the consistency of selecting NOS units

  14. Providing Behavioral Feedback to Students in an Alternative High School Setting

    Science.gov (United States)

    Whitcomb, Sara A.; Hefter, Sheera; Barker, Elizabeth

    2016-01-01

    This column provides an example method for improving the consistency and quality of daily behavioral feedback provided to students in an alternative high school setting. Often, homeroom or advisory periods are prime points in the day for students to review their behavior from the previous day and set goals for a successful day to come. The method…

  15. Accuracy of identification of low or high risk lifting during standardised lifting situations

    DEFF Research Database (Denmark)

    Brandt, Mikkel; Madeleine, Pascal; Samani, Afshin

    2018-01-01

    The aim was to classify lifting activities into low and high risk categories (according to The Danish Working Environment Authority guidelines) based on surface electromyography (sEMG) and trunk inclination (tri-axial accelerometer) measurements. Lifting tasks with different weights, horizontal...... biomechanical loads, based on individual sEMG and kinematics from an entire working day. These methods may be more cost-effective and may complement observations commonly used by practitioners....

  16. High-Accuracy Ion Range Measurements using Fluorescent Nuclear Track Detectors

    OpenAIRE

    Klimpki, Grischa

    2012-01-01

    Novel fluorescent nuclear track detectors (FNTDs) are based on single aluminum oxide crystals doped with carbon and magnesium and laser scanning fluorescent microscopy. The detector crystals contain high concentrations of colour centres, consisting of two oxygen vacancies charge compensated by two magnesium ions. These colour centres exhibit radiochromic transformations under ionising radiation. Laser-induced fluorescence can then be stimulated with a red laser without photoionisation of the ...

  17. Two-dimensional DOA Estimation with High Accuracy for MIMO Radar Using Cross Array

    Directory of Open Access Journals (Sweden)

    Liang Hao

    2016-06-01

    Full Text Available In this study, we investigate the estimation of the Two-Dimensional (2D Direction Of Arrival (DOA in monostatic multiple-input–multiple-output radar with cross array and propose a novel, highly accurate DOA estimation method based on unitary transformation. First, we design a new unitary matrix using the central symmetry of a cross array at transmit and receive sites. Then, the rotational invariance relationships of these arrays with long and short baselines can be transformed into a real-value field via unitary transformation. In addition, non-ambiguous and highly accurate 2D DOA estimations can be obtained using a unitary dual-resolution ESPRIT algorithm. Simulations show that the proposed method can estimate 2D highly accurate spatial angles using automatic pairing without incurring the expense of array aperture and peak searching. Compared with traditional unitary transformation, the steering vectors of transmit and receive arrays can be transformed into real-value fields via the unitary matrix and the transformation method of our scheme, respectively. This effectively overcomes the problem of shift invariance factors in real-value fields that cannot be extracted using traditional algorithms. Therefore, the proposed method can absolutely compute eigenvalue decomposition and estimate parameters in a real-value field, resulting in lower computational complexity compared with traditional methods. Simulation results verify both the correctness of our theoretical analysis and the effectiveness of the proposed algorithm.

  18. Continuous assessment of land mapping accuracy at High Resolution from global networks of atmospheric and field observatories -concept and demonstration

    Science.gov (United States)

    Sicard, Pierre; Martin-lauzer, François-regis

    2017-04-01

    In the context of global climate change and adjustment/resilience policies' design and implementation, there is a need not only i. for environmental monitoring, e.g. through a range of Earth Observations (EO) land "products" but ii. for a precise assessment of uncertainties of the aforesaid information that feed environmental decision-making (to be introduced in the EO metadata) and also iii. for a perfect handing of the thresholds which help translate "environment tolerance limits" to match detected EO changes through ecosystem modelling. Uncertainties' insight means precision and accuracy's knowledge and subsequent ability of setting thresholds for change detection systems. Traditionally, the validation of satellite-derived products has taken the form of intensive field campaigns to sanction the introduction of data processors in Payload Data Ground Segments chains. It is marred by logistical challenges and cost issues, reason why it is complemented by specific surveys at ground-based monitoring sites which can provide near-continuous observations at a high temporal resolution (e.g. RadCalNet). Unfortunately, most of the ground-level monitoring sites, in the number of 100th or 1000th, which are part of wider observation networks (e.g. FLUXNET, NEON, IMAGINES) mainly monitor the state of the atmosphere and the radiation exchange at the surface, which are different to the products derived from EO data. In addition they are "point-based" compared to the EO cover to be obtained from Sentinel-2 or Sentinel-3. Yet, data from these networks, processed by spatial extrapolation models, are well-suited to the bottom-up approach and relevant to the validation of vegetation parameters' consistency (e.g. leaf area index, fraction of absorbed photosynthetically active radiation). Consistency means minimal errors on spatial and temporal gradients of EO products. Test of the procedure for land-cover products' consistency assessment with field measurements delivered by worldwide

  19. Nurses and Dietitians Differ in Food Safety Information Provided to Highly Susceptible Clients

    Science.gov (United States)

    Buffer, Janet; Kendall, Patricia; Medeiros, Lydia; Schroeder, Mary; Sofos, John

    2013-01-01

    Objective: To determine content, education channels, and motivational factors that influence what health professionals teach about safe food handling to populations who are highly susceptible for foodborne illnesses. To assess the differences in information provided by health professionals to highly susceptible populations. Design: Descriptive,…

  20. An experimental study on the development and application of ultra-high-accuracy and high-speed groove die set

    Science.gov (United States)

    Kim, Gun-hoi; So, Jung D.; Kwon, Kyu-sik; Byun, Jong-won

    2007-12-01

    This research designed and developed a groove type die set which improved life span of the die set by eliminating pointcontacts of steel balls with the guide post. The guide post consisted of a steel-ball retainer, a steel-ball retainer stopper, a guide bush, a guide pin, a snap ring, and a spring. The steel-ball retainer has 72 holes with 8 columns of 9 holes in each column. The inner surface of the guide bush was grinded (surface roughness: Ra = 0.2μm, accuracy: 0 ~ -0.002 mm) after NC turning and it was treated with heat. Also, a line of small intermediate pocket was processed inside of the guide bush for lubrication and elimination of foreign materials. Guide grooves for steel balls were processed using a wire EDM (Electrical Discharge Machining) after the heat treatment. With such a design of the guide post stated above, loads against steel balls could be dispersed greatly by the line contacts through the guide groove between the guide pin and the guide bush, and the life span of the guide post could be expanded semi-permanently.

  1. A Time Projection Chamber for High Accuracy and Precision Fission Cross-Section Measurements

    Energy Technology Data Exchange (ETDEWEB)

    T. Hill; K. Jewell; M. Heffner; D. Carter; M. Cunningham; V. Riot; J. Ruz; S. Sangiorgio; B. Seilhan; L. Snyder; D. M. Asner; S. Stave; G. Tatishvili; L. Wood; R. G. Baker; J. L. Klay; R. Kudo; S. Barrett; J. King; M. Leonard; W. Loveland; L. Yao; C. Brune; S. Grimes; N. Kornilov; T. N. Massey; J. Bundgaard; D. L. Duke; U. Greife; U. Hager; E. Burgett; J. Deaven; V. Kleinrath; C. McGrath; B. Wendt; N. Hertel; D. Isenhower; N. Pickle; H. Qu; S. Sharma; R. T. Thornton; D. Tovwell; R. S. Towell; S.

    2014-09-01

    The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4p acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross-sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.

  2. A time projection chamber for high accuracy and precision fission cross-section measurements

    Science.gov (United States)

    Heffner, M.; Asner, D. M.; Baker, R. G.; Baker, J.; Barrett, S.; Brune, C.; Bundgaard, J.; Burgett, E.; Carter, D.; Cunningham, M.; Deaven, J.; Duke, D. L.; Greife, U.; Grimes, S.; Hager, U.; Hertel, N.; Hill, T.; Isenhower, D.; Jewell, K.; King, J.; Klay, J. L.; Kleinrath, V.; Kornilov, N.; Kudo, R.; Laptev, A. B.; Leonard, M.; Loveland, W.; Massey, T. N.; McGrath, C.; Meharchand, R.; Montoya, L.; Pickle, N.; Qu, H.; Riot, V.; Ruz, J.; Sangiorgio, S.; Seilhan, B.; Sharma, S.; Snyder, L.; Stave, S.; Tatishvili, G.; Thornton, R. T.; Tovesson, F.; Towell, D.; Towell, R. S.; Watson, S.; Wendt, B.; Wood, L.; Yao, L.

    2014-09-01

    The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4π acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross-sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.

  3. High accuracy 235U(n,f data in the resonance energy region

    Directory of Open Access Journals (Sweden)

    Paradela C.

    2016-01-01

    Full Text Available The 235U neutron-induced cross section is widely used as reference cross section for measuring other fission cross sections, but in the resonance region it is not considered as an IAEA standard because of the scarce experimental data covering the full region. In this work, we deal with a new analysis of the experimental data obtained with a detection setup based on parallel plate ionization chambers (PPACs at the CERN n_TOF facility in the range from 1 eV to 10 keV. The relative cross section has been normalised to the IAEA value in the region between 7.8 and 11 eV, which is claimed as well-known. Comparison with the ENDF/B-VII evaluation and the IAEA reference file from 100 eV to 10 keV are provided.

  4. Improving the accuracy: volatility modeling and forecasting using high-frequency data and the variational component

    Directory of Open Access Journals (Sweden)

    Manish Kumar

    2010-06-01

    Full Text Available In this study, we predict the daily volatility of the S&P CNX NIFTY market index of India using the basic ‘heterogeneous autoregressive’ (HAR and its variant. In doing so, we estimated several HAR and Log form of HAR models using different regressor. The different regressors were obtained by extracting the jump and continuous component and the threshold jump and continuous component from the realized volatility. We also tried to investigate whether dividing volatility into simple and threshold jumps and continuous variation yields a substantial improvement in volatility forecasting or not. The results provide the evidence that inclusion of realized bipower variance in the HAR models helps in predicting future volatility.

  5. Modelling and Control of Stepper Motors for High Accuracy Positioning Systems Used in Radioactive Environments

    CERN Document Server

    Picatoste Ruilope, Ricardo; Masi, Alessandro

    Hybrid Stepper Motors are widely used in open-loop position applications. They are the choice of actuation for the collimators in the Large Hadron Collider, the largest particle accelerator at CERN. In this case the positioning requirements and the highly radioactive operating environment are unique. The latter forces both the use of long cables to connect the motors to the drives which act as transmission lines and also prevents the use of standard position sensors. However, reliable and precise operation of the collimators is critical for the machine, requiring the prevention of step loss in the motors and maintenance to be foreseen in case of mechanical degradation. In order to make the above possible, an approach is proposed for the application of an Extended Kalman Filter to a sensorless stepper motor drive, when the motor is separated from its drive by long cables. When the long cables and high frequency pulse width modulated control voltage signals are used together, the electrical signals difer greatl...

  6. High accuracy mantle convection simulation through modern numerical methods - II: realistic models and problems

    Science.gov (United States)

    Heister, Timo; Dannberg, Juliane; Gassmöller, Rene; Bangerth, Wolfgang

    2017-08-01

    Computations have helped elucidate the dynamics of Earth's mantle for several decades already. The numerical methods that underlie these simulations have greatly evolved within this time span, and today include dynamically changing and adaptively refined meshes, sophisticated and efficient solvers, and parallelization to large clusters of computers. At the same time, many of the methods - discussed in detail in a previous paper in this series - were developed and tested primarily using model problems that lack many of the complexities that are common to the realistic models our community wants to solve today. With several years of experience solving complex and realistic models, we here revisit some of the algorithm designs of the earlier paper and discuss the incorporation of more complex physics. In particular, we re-consider time stepping and mesh refinement algorithms, evaluate approaches to incorporate compressibility, and discuss dealing with strongly varying material coefficients, latent heat, and how to track chemical compositions and heterogeneities. Taken together and implemented in a high-performance, massively parallel code, the techniques discussed in this paper then allow for high resolution, 3-D, compressible, global mantle convection simulations with phase transitions, strongly temperature dependent viscosity and realistic material properties based on mineral physics data.

  7. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption.

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (∼100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ∼0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  8. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  9. Accuracy optimization of high-speed AFM measurements using Design of Experiments

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, F.; Hansen, Hans Nørgaard

    2010-01-01

    Atomic Force Microscopy (AFM) is being increasingly employed in industrial micro/nano manufacturing applications and integrated into production lines. In order to achieve reliable process and product control at high measuring speed, instrument optimization is needed. Quantitative AFM measurement......, the estimated dimensions of measured features. The definition of scan settings is based on a comprehensive optimization that targets maximization of information from collected data and minimization of measurement uncertainty and scan time. The Design of Experiments (DOE) technique is proposed and applied...... to perform the optimization of AFM measurements on calibrated one-dimensional silicon grating featuring a triangular periodical profile (slopes of 54.7 degrees, period of 3 μm)....

  10. Synthetic Conditions for High-Accuracy Size Control of PbS Quantum Dots

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jianbing; Crisp, Ryan W.; Gao, Jianbo; Kroupa, Daniel M.; Beard, Matthew C.; Luther, Joseph M.

    2015-05-21

    Decreasing the variability in quantum dot (QD) syntheses is desirable for better uniformity of samples for use in QD-based studies and applications. Here we report a highly reproducible linear relationship between the concentration of ligand (in this case oleic acid, OA) and the lowest energy exciton peak position (nm) of the resulting PbS QDs for various hot-injection temperatures. Thus, for a given injection temperature, the size of the PbS QD product is purely controlled by the amount of OA. We used this relationship to study PbS QD solar cells that are fabricated from the same size of PbS QDs but synthesized using four different injection temperatures: 95, 120, 150, and 185 °C. We find that the power conversion efficiency does not depend on injection temperature but that the Voc is higher for QDs synthesized at lower temperatures while the Jsc is improved in higher temperature QDs.

  11. Stereotactic CT-Guided Percutaneous Microwave Ablation of Liver Tumors With the Use of High-Frequency Jet Ventilation: An Accuracy and Procedural Safety Study.

    Science.gov (United States)

    Engstrand, Jennie; Toporek, Grzegorz; Harbut, Piotr; Jonas, Eduard; Nilsson, Henrik; Freedman, Jacob

    2017-01-01

    The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [± SD] lesion diameter, 14.9 ± 5.9 mm; mean lesion location depth, 87.5 ± 27.3 mm). The antennae were placed with a mean lateral error of 4.0 ± 2.5 mm, a depth error of 3.4 ± 3.2 mm, and a total error of 5.8 ± 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 ± 556.5 mGy × cm, but medical personnel were not exposed to irradiation. Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the needle. Therefore, it is technically feasible and applicable for safe treatments.

  12. High Speed and High Accuracy Control of Industrial Articulated Robot Arms with Jerk Restraint by Spline Interpolated Taught Data

    Science.gov (United States)

    Goto, Satoru; Iwanaga, Takuya; Kyura, Nobuhiro; Nakamura, Masatoshi

    In industrial robot arms, high speed and high accurate operation is required. However in case of high speed operation, it often arises high jerk, i, e., rapid change of acceleration. Jerk causes deterioration of control performance such as vibration of a tip of a robot arm. It is, therefore, important to reduce jerk during robot arm operation. In this research, spline interpolation is used to reduce jerk under torque and speed constraints. Effectiveness of the proposed method was assured by experimental results and simulation results of an actual robot arm.

  13. High-accuracy local positioning network for the alignment of the Mu2e experiment.

    Energy Technology Data Exchange (ETDEWEB)

    Hejdukova, Jana B. [Czech Technical Univ., Prague (Czech Republic)

    2017-06-01

    This Diploma thesis describes the establishment of a high-precision local positioning network and accelerator alignment for the Mu2e physics experiment. The process of establishing new network consists of few steps: design of the network, pre-analysis, installation works, measurements of the network and making adjustments. Adjustments were performed using two approaches. First is a geodetic approach of taking into account the Earth’s curvature and the metrological approach of a pure 3D Cartesian system on the other side. The comparison of those two approaches is performed and evaluated in the results and compared with expected differences. The effect of the Earth’s curvature was found to be significant for this kind of network and should not be neglected. The measurements were obtained with Absolute Tracker AT401, leveling instrument Leica DNA03 and gyrotheodolite DMT Gyromat 2000. The coordinates of the points of the reference network were determined by the Least Square Meth od and the overall view is attached as Annexes.

  14. High Accuracy ab Initio Calculations of Rotational-Vibrational Levels of the HCN/HNC System.

    Science.gov (United States)

    Makhnev, Vladimir Yu; Kyuberis, Aleksandra A; Zobov, Nikolai F; Lodi, Lorenzo; Tennyson, Jonathan; Polyansky, Oleg L

    2018-02-08

    Highly accurate ab initio calculations of vibrational and rotational-vibrational energy levels of the HCN/HNC (hydrogen cyanide/hydrogen isocyanide) isomerising system are presented for several isotopologues. All-electron multireference configuration interaction (MRCI) electronic structure calculations were performed using basis sets up to aug-cc-pCV6Z on a grid of 1541 geometries. The ab initio energies were used to produce an analytical potential energy surface (PES) describing the two minima simultaneously. An adiabatic Born-Oppenheimer diagonal correction (BODC) correction surface as well as a relativistic correction surface were also calculated. These surfaces were used to compute vibrational and rotational-vibrational energy levels up to 25 000 cm -1 which reproduce the extensive set of experimentally known HCN/HNC levels with a root-mean-square deviation σ = 1.5 cm -1 . We studied the effect of nonadiabatic effects by introducing opportune radial and angular corrections to the nuclear kinetic energy operator. Empirical determination of two nonadiabatic parameters results in observed energies up to 7000 cm -1 for four HCN isotopologues (HCN, DCN, H 13 CN, and HC 15 N) being reproduced with σ = 0.37 cm -1 . The height of the isomerization barrier, the isomerization energy and the dissociation energy were computed using a number of models; our best results are 16 809.4, 5312.8, and 43 729 cm -1 , respectively.

  15. Meditation Experience Predicts Introspective Accuracy

    Science.gov (United States)

    Fox, Kieran C. R.; Zakarauskas, Pierre; Dixon, Matt; Ellamil, Melissa; Thompson, Evan; Christoff, Kalina

    2012-01-01

    The accuracy of subjective reports, especially those involving introspection of one's own internal processes, remains unclear, and research has demonstrated large individual differences in introspective accuracy. It has been hypothesized that introspective accuracy may be heightened in persons who engage in meditation practices, due to the highly introspective nature of such practices. We undertook a preliminary exploration of this hypothesis, examining introspective accuracy in a cross-section of meditation practitioners (1–15,000 hrs experience). Introspective accuracy was assessed by comparing subjective reports of tactile sensitivity for each of 20 body regions during a ‘body-scanning’ meditation with averaged, objective measures of tactile sensitivity (mean size of body representation area in primary somatosensory cortex; two-point discrimination threshold) as reported in prior research. Expert meditators showed significantly better introspective accuracy than novices; overall meditation experience also significantly predicted individual introspective accuracy. These results suggest that long-term meditators provide more accurate introspective reports than novices. PMID:23049790

  16. Spatial correlation of high density EMG signals provides features robust to electrode number and shift in pattern recognition for myocontrol.

    Science.gov (United States)

    Stango, Antonietta; Negro, Francesco; Farina, Dario

    2015-03-01

    Research on pattern recognition for myoelectric control has usually focused on a small number of electromyography (EMG) channels because of better clinical acceptability and low computational load with respect to multi-channel EMG. However, recently, high density (HD) EMG technology has substantially improved, also in practical usability, and can thus be applied in myocontrol. HD EMG provides several closely spaced recordings in multiple locations over the skin surface. This study considered the use of HD EMG for controlling upper limb prostheses, based on pattern recognition. In general, robustness and reliability of classical pattern recognition systems are influenced by electrode shift in dons and doff, and by the presence of malfunctioning channels. The aim of this study is to propose a new approach to attenuate these issues. The HD EMG grid of electrodes is an ensemble of sensors that records data spatially correlated. The experimental variogram, which is a measure of the degree of spatial correlation, was used as feature for classification, contrary to previous approaches that are based on temporal or frequency features. The classification based on the variogram was tested on seven able-bodied subjects and one subject with amputation, for the classification of nine and seven classes, respectively. The performance of the proposed approach was comparable with the classic methods based on time-domain and autoregressive features (average classification accuracy over all methods ∼ 95% for nine classes). However, the new spatial features demonstrated lower sensitivity to electrode shift ( ± 1 cm) with respect to the classic features . When even just one channel was noisy, the classification accuracy dropped by ∼ 10% for all methods. However, the new method could be applied without any retraining to a subset of high-quality channels whereas the classic methods require retraining when some channels are omitted. In conclusion, the new spatial feature space

  17. A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints.

    Science.gov (United States)

    Haut, T L; Hull, M L; Howell, S M

    1998-06-01

    This paper describes the design and performance evaluation of a three-dimensional (3-D) coordinate digitizing system (3-DCDS) for measuring both soft and hard biological tissue. The system incorporates a visible semiconducting laser beam and an X-Y positioning table to directly measure 3-D coordinates that define surface points. Experiments conducted to evaluate the performance of the system showed that it delivers an accuracy of 0.1 microm in the Z-direction and 1.4 microm in the X-Y plane, and an overall system root-mean-squared error (RMSE) of 8 microm on surfaces with slopes of less than 45 degrees . This error is lower than that of previously reported measurement techniques. The 3-DCDS measures 3-D coordinates of surface points uniformly separated by 500 microm in the X-Y plane. Because the 3-DCDS is automated, the coordinates are measured efficiently and the accuracy is independent of operator skill. These highly accurate coordinates can be easily incorporated into nodal values for 3-D finite element models (FEM) of diarthrodial joints. To show the use of the 3-DCDS, the 3-D surface coordinates of human menisci were measured from a cadaver specimen.

  18. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  19. An examination of direct selection typing rate and accuracy for persons with high-level spinal cord injury using QWERTY and default on-screen keyboards.

    Science.gov (United States)

    Hurlburt, M; Ottenbacher, K J

    1992-01-01

    A single-subject rapid alternating treatment design with replication was used to compare the efficiency of two keyboard layouts, QWERTY and default, for persons with high-level spinal cord injury. The LIAISON system and proportional-drive chin controller provided computer access/writing to four subjects. Three efficiency characteristics were examined: keystrokes per minute, keystroke accuracy, and keystroke corrections. Baseline sessions were followed by 10 to 12 alternating treatment sessions for all subjects. Each alternating treatment session involved six text entry trials--three text entry trials using the QWERTY keyboard layout and three using the default keyboard layout. Four follow-up sessions were completed for each subject using the default keyboard configuration. Data analysis revealed that the default keyboard layout provided greater keystrokes per minute for two of the subjects. The keystroke accuracy was between 98% and 100% for all subjects on both keyboard layouts. The findings of this investigation revealed no clinically significant difference in typing performance across the two keyboard layouts for the participating subjects. The results also indicate that previous experience with a keyboard configuration is an important factor in determining performance. A possible treatment interaction or carryover effect between the two keyboard configurations was noted and has implications for the type of single-subject design used in future investigations.

  20. High-fidelity multiactor emergency preparedness training for patient care providers.

    Science.gov (United States)

    Scott, Lancer A; Maddux, P Tim; Schnellmann, Jennifer; Hayes, Lauren; Tolley, Jessica; Wahlquist, Amy E

    2012-01-01

    Providing comprehensive emergency preparedness training (EPT) for patient care providers is important to the future success of emergency preparedness operations in the United States. Disasters are rare, complex events involving many patients and environmental factors that are difficult to reproduce in a training environment. Few EPT programs possess both competency-driven goals and metrics to measure life-saving performance during a multiactor simulated disaster. The development of an EPT curriculum for patient care providers-provided first to medical students, then to a group of experienced disaster medical providers-that recreates a simulated clinical disaster using a combination of up to 15 live actors and six high-fidelity human simulators is described. Specifically, the authors detail the Center for Health Professional Training and Emergency Response's (CHPTER's) 1-day clinical EPT course including its organization, core competency development, medical student self-evaluation, and course assessment. Two 1-day courses hosted by CHPTER were conducted in a university simulation center. Students who completed the course improved their overall knowledge and comfort level with EPT skills. The authors believe this is the first published description of a curriculum method that combines high-fidelity, multiactor scenarios to measure the life-saving performance of patient care providers utilizing a clinical disaster scenario with > 10 patients at once. A larger scale study, or preferably a multicenter trial, is needed to further study the impact of this curriculum and its potential to protect provider and patient lives.

  1. The linear interplay of intrinsic and extrinsic noises ensures a high accuracy of cell fate selection in budding yeast

    Science.gov (United States)

    Li, Yongkai; Yi, Ming; Zou, Xiufen

    2014-01-01

    To gain insights into the mechanisms of cell fate decision in a noisy environment, the effects of intrinsic and extrinsic noises on cell fate are explored at the single cell level. Specifically, we theoretically define the impulse of Cln1/2 as an indication of cell fates. The strong dependence between the impulse of Cln1/2 and cell fates is exhibited. Based on the simulation results, we illustrate that increasing intrinsic fluctuations causes the parallel shift of the separation ratio of Whi5P but that increasing extrinsic fluctuations leads to the mixture of different cell fates. Our quantitative study also suggests that the strengths of intrinsic and extrinsic noises around an approximate linear model can ensure a high accuracy of cell fate selection. Furthermore, this study demonstrates that the selection of cell fates is an entropy-decreasing process. In addition, we reveal that cell fates are significantly correlated with the range of entropy decreases. PMID:25042292

  2. High-density surface electromyography provides reliable estimates of motor unit behavior.

    Science.gov (United States)

    Martinez-Valdes, E; Laine, C M; Falla, D; Mayer, F; Farina, D

    2016-06-01

    To assess the intra- and inter-session reliability of estimates of motor unit behavior and muscle fiber properties derived from high-density surface electromyography (HDEMG). Ten healthy subjects performed submaximal isometric knee extensions during three recording sessions (separate days) at 10%, 30%, 50% and 70% of their maximum voluntary effort. The discharge timings of motor units of the vastus lateralis and medialis muscles were automatically identified from HDEMG by a decomposition algorithm. We characterized the number of detected motor units, their discharge rates, the coefficient of variation of their inter-spike intervals (CoVisi), the action potential conduction velocity and peak-to-peak amplitude. Reliability was assessed for each motor unit characteristics by intra-class correlation coefficient (ICC). Additionally, a pulse-to-noise ratio (PNR) was calculated, to verify the accuracy of the decomposition. Good to excellent reliability within and between sessions was found for all motor unit characteristics at all force levels (ICCs>0.8), with the exception of CoVisi that presented poor reliability (ICC95%). Motor unit features can be assessed non-invasively and reliably within and across sessions over a wide range of force levels. These results suggest that it is possible to characterize motor units in longitudinal intervention studies. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Provider knowledge of trivalent inactivated and high-dose influenza vaccines.

    Science.gov (United States)

    Tewell, Chad; Wright, Patty W; Talbot, H Keipp

    2014-10-21

    The objective of this study was to assess provider knowledge about trivalent inactivated and high dose influenza vaccines. Hence, a 20-item survey was distributed to providers within the Internal Medicine department at an urban academic medical center. Two hundred and eighty-one (24.5%) providers responded. The correct response rate was 63.2%. The highest performing subspecialties were infectious diseases (80.5%), endocrinology (69.2%), and pulmonary (68%). Those who received an influenza vaccine during the most recent season scored significantly higher than those who did not (63.6% vs. 43.6%, p=.001). Areas where respondents did poorly included questions pertaining to contraindications to immunizations (27.4%), common adverse events after immunization (29.2%), target antigen (73.5%), number of strains in the trivalent inactivated vaccine (62.9%), and time to immunity (61.4%). High dose vaccine knowledge was poor, with 37% of providers unaware of its existence. Significant gaps in provider knowledge exist regarding both trivalent inactivated and high dose influenza vaccines. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Providing wireless bandwidth for high-speed rail operations : final report.

    Science.gov (United States)

    2016-07-01

    This project examined the possibility of providing wireless communication for train control systems on American high-speed trains. In this : study, the key issue is that the frequencies allocated for rail operations in the U.S. and the frequencies us...

  5. Providing high-quality HIV care in a deeply rural setting – the ...

    African Journals Online (AJOL)

    Providing high-quality HIV care in a deeply rural setting – the Zithulele experience. C Young, B Gaunt. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.7196/sajhivmed.1035 · AJOL African Journals Online. HOW TO ...

  6. Double-pattern triangular pulse width modulation technique for high-accuracy high-speed 3D shape measurement.

    Science.gov (United States)

    Wang, Yajun; Jiang, Chufan; Zhang, Song

    2017-11-27

    Using 1-bit binary patterns for three-dimensional (3D) shape measurement has been demonstrated as being advantageous over using 8-bit sinusoidal patterns in terms of achievable speeds. However, the phase quality generated by binary pattern(s) typically are not high if only a small number of phase-shifted patterns are used. This paper proposes a method to improve the phase quality by representing each pattern with the difference of two binary patterns: the first binary pattern is generated by triangular pulse width modulation (TPWM) technique, and the second being π shifted from the first pattern that is also generated by TPWM technique. The phase is retrieved by applying a three-step phase-shifting algorithm to the difference patterns. Through optimizing the modulation frequency of the triangular carrier signal, we demonstrate that a high-quality phase can be generated for a wide range of fringe periods (e.g., from 18 to 1140 pixels) with only six binary patterns. Since only 1-bit binary patterns are required for 3D shape measurement, this paper will present a real-time 3D shape measurement system that can achieve 30 Hz.

  7. Novel technique to suppress hydrocarbon contamination for high accuracy determination of carbon content in steel by FE-EPMA.

    Science.gov (United States)

    Yamashita, Takako; Tanaka, Yuji; Yagoshi, Masayasu; Ishida, Kiyohito

    2016-07-19

    In multiphase steels, control of the carbon contents in the respective phases is the most important factor in alloy design for achieving high strength and high ductility. However, it is unusually difficult to determine the carbon contents in multiphase structures with high accuracy by electron probe microanalysis (EPMA) due to the unavoidable effect of hydrocarbon contamination during measurements. We have investigated new methods for suppressing hydrocarbon contamination during field emission (FE) EPMA measurements as well as a conventional liquid nitrogen trap. Plasma cleaner inside the specimen chamber results in a improvement of carbon-content determination by point analysis, increasing precision tenfold from the previous 0.1 mass%C to 0.01 mass%C. Stage heating at about 100 °C dramatically suppresses contamination growth during continuous point measurement and mapping. By the combination of above two techniques, we successfully visualized the two-dimensional carbon distribution in a dual-phase steel. It was also noted that the carbon concentrations at the ferrite/martensite interfaces were not the same across all interfaces, and local variation was observed. The developed technique is expected to be a powerful tool for understanding the mechanisms of mechanical properties and microstructural evolution, thereby contributing to the design of new steel products with superior properties.

  8. Novel technique to suppress hydrocarbon contamination for high accuracy determination of carbon content in steel by FE-EPMA

    Science.gov (United States)

    Yamashita, Takako; Tanaka, Yuji; Yagoshi, Masayasu; Ishida, Kiyohito

    2016-07-01

    In multiphase steels, control of the carbon contents in the respective phases is the most important factor in alloy design for achieving high strength and high ductility. However, it is unusually difficult to determine the carbon contents in multiphase structures with high accuracy by electron probe microanalysis (EPMA) due to the unavoidable effect of hydrocarbon contamination during measurements. We have investigated new methods for suppressing hydrocarbon contamination during field emission (FE) EPMA measurements as well as a conventional liquid nitrogen trap. Plasma cleaner inside the specimen chamber results in a improvement of carbon-content determination by point analysis, increasing precision tenfold from the previous 0.1 mass%C to 0.01 mass%C. Stage heating at about 100 °C dramatically suppresses contamination growth during continuous point measurement and mapping. By the combination of above two techniques, we successfully visualized the two-dimensional carbon distribution in a dual-phase steel. It was also noted that the carbon concentrations at the ferrite/martensite interfaces were not the same across all interfaces, and local variation was observed. The developed technique is expected to be a powerful tool for understanding the mechanisms of mechanical properties and microstructural evolution, thereby contributing to the design of new steel products with superior properties.

  9. On the Static Accuracy of Charge-Discharge Units Intended for Electrical Tests of High Capacity Li-ion Batteries

    Science.gov (United States)

    Mizrah, E. A.; Lobanov, D. K.; Kopylov, E. A.; Balakirev, R. V.; Fedchenko, A. S.

    2017-10-01

    Performing of the cycle testing according to the principles of Dynamic Stress Test can significantly reduce the overall time of development and production of batteries, which in turn allows reducing the cost of designing and testing of the spacecraft power systems. Performing of Dynamic Stress Test require special charge-discharge units that allows to perform a full cycle of electrical tests of batteries, including cyclic testing. Providing the required accuracy of measurement and stabilization of certain attributes of Li-ion battery operating modes is one of the problems that arise during thedevelopment of such charge-discharge units. The following attributes are of particular interest: charge and discharge currents, discharge powers, battery voltages. Analysis of the charge-discharge unit as a control system allows evaluating the steady-state stabilization error of the required attributes of the developed device. Moreover, using a digital integrator in the control system of the charge-discharge unit allows providing specified values of steady-state stabilization error of required attributes in different test modes.

  10. High-Capacity Communications from Martian Distances Part 4: Assessment of Spacecraft Pointing Accuracy Capabilities Required For Large Ka-Band Reflector Antennas

    Science.gov (United States)

    Hodges, Richard E.; Sands, O. Scott; Huang, John; Bassily, Samir

    2006-01-01

    Improved surface accuracy for deployable reflectors has brought with it the possibility of Ka-band reflector antennas with extents on the order of 1000 wavelengths. Such antennas are being considered for high-rate data delivery from planetary distances. To maintain losses at reasonable levels requires a sufficiently capable Attitude Determination and Control System (ADCS) onboard the spacecraft. This paper provides an assessment of currently available ADCS strategies and performance levels. In addition to other issues, specific factors considered include: (1) use of "beaconless" or open loop tracking versus use of a beacon on the Earth side of the link, and (2) selection of fine pointing strategy (body-fixed/spacecraft pointing, reflector pointing or various forms of electronic beam steering). Capabilities of recent spacecraft are discussed.

  11. THE IMPACT OF MODERATE AND HIGH INTENSITY TOTAL BODY FATIGUE ON PASSING ACCURACY IN EXPERT AND NOVICE BASKETBALL PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2006-06-01

    Full Text Available Despite the acknowledged importance of fatigue on performance in sport, ecologically sound studies investigating fatigue and its effects on sport-specific skills are surprisingly rare. The aim of this study was to investigate the effect of moderate and high intensity total body fatigue on passing accuracy in expert and novice basketball players. Ten novice basketball players (age: 23.30 ± 1.05 yrs and ten expert basketball players (age: 22.50 ± 0.41 yrs volunteered to participate in the study. Both groups performed the modified AAHPERD Basketball Passing Test under three different testing conditions: rest, moderate intensity and high intensity total body fatigue. Fatigue intensity was established using a percentage of the maximal number of squat thrusts performed by the participant in one minute. ANOVA with repeated measures revealed a significant (F 2,36 = 5.252, p = 0.01 level of fatigue by level of skill interaction. On examination of the mean scores it is clear that following high intensity total body fatigue there is a significant detriment in the passing performance of both novice and expert basketball players when compared to their resting scores. Fundamentally however, the detrimental impact of fatigue on passing performance is not as steep in the expert players compared to the novice players. The results suggest that expert or skilled players are better able to cope with both moderate and high intensity fatigue conditions and maintain a higher level of performance when compared to novice players. The findings of this research therefore, suggest the need for trainers and conditioning coaches in basketball to include moderate, but particularly high intensity exercise into their skills sessions. This specific training may enable players at all levels of the game to better cope with the demands of the game on court and maintain a higher standard of play

  12. Social Power Increases Interoceptive Accuracy

    Directory of Open Access Journals (Sweden)

    Mehrad Moeini-Jazani

    2017-08-01

    Full Text Available Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research.

  13. DVR3DUV: a Suite for High Accuracy Calculations of Ro-Vibronic Spectra of Triatomic MOLECUlES

    Science.gov (United States)

    Zak, Emil J.; Tennyson, Jonathan

    2017-06-01

    We present a computer code (DVR3DUV) for calculations of high-accuracy ro-vibronic spectra of triatomic molecules. The current implementation is an extension to the DVR3D suite [1], which operates with the exact kinetic energy operator, a single potential energy surface and a single dipole moment surface (ro-vibrational transitions only). The main function of the new code is calculation of transition intensities between different electronic states in the rotational-vibrational resolution. As a case study, two electronic states of SO_2 molecule are considered. Ro-vibrational wavefunctions and energy levels for the ground ˜{X}^1A_1 state of SO_2 are calculated using Ames PES [2], while energy levels and wavefunctions of the ˜{C}^1B_2 state are calculated using ab initio PES (MRCI-F12-AVTZ). Transition intensities are computed using a) Franck-Condon approximation; b) ab initio dipole moment surface between the two electronic states. Results are compared to the latest theoretical and experimental works. Future applications of the DVR3DUV code will focus on highly accurate electronic spectra for atmospherically important species, such as ozone molecule. {1} J. Tennyson, M A. Kostin, P. Barletta, G. J. Harris, O L. Polyansky, J. Ramanlal, N. F. Zobov, Computer Physics Communications 163 (2004) 85-116. {2} X. Huang, D. W. Schwenke, T. J. Lee, J Chem Phys. 2014 ;140(11):11431

  14. High-accuracy determination of the neutron flux in the new experimental area nTOF-EAR2 at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Sabate-Gilarte, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Barbagallo, M.; Colonna, N.; Damone, L.; Belloni, F.; Mastromarco, M.; Tagliente, G.; Variale, V. [Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Bari (Italy); Gunsing, F.; Berthoumieux, E.; Diakaki, M.; Papaevangelou, T.; Dupont, E. [Universite Paris-Saclay, CEA Irfu, Gif-sur-Yvette (France); Zugec, P.; Bosnar, D. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Vlachoudis, V.; Aberle, O.; Brugger, M.; Calviani, M.; Cardella, R.; Cerutti, F.; Chiaveri, E.; Ferrari, A.; Kadi, Y.; Losito, R.; Macina, D.; Montesano, S.; Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Chen, Y.H.; Audouin, L.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Stamatopoulos, A.; Kokkoris, M.; Tsinganis, A.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Lerendegui-Marco, J.; Cortes-Giraldo, M.A.; Guerrero, C.; Quesada, J.M. [Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Villacorta, A. [University of Salamanca, Salamanca (Spain); Cosentino, L.; Finocchiaro, P.; Piscopo, M. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Musumarra, A. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Universita di Catania, Dipartimento di Fisica, Catania (Italy); Andrzejewski, J.; Gawlik, A.; Marganiec, J.; Perkowski, J. [University of Lodz, Lodz (Poland); Becares, V.; Balibrea, J.; Cano-Ott, D.; Garcia, A.R.; Gonzalez, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Bacak, M.; Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Technische Universitaet Wien, Wien (Austria); Baccomi, R.; Milazzo, P.M. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste (Italy); Barros, S.; Ferreira, P.; Goncalves, I.F.; Vaz, P. [Instituto Superior Tecnico, Lisbon (Portugal); Becvar, F.; Krticka, M.; Valenta, S. [Charles University, Prague (Czech Republic); Beinrucker, C.; Goebel, K.; Heftrich, T.; Reifarth, R.; Schmidt, S.; Weigand, M.; Wolf, C. [Goethe University Frankfurt, Frankfurt (Germany); Billowes, J.; Frost, R.J.W.; Ryan, J.A.; Smith, A.G.; Warren, S.; Wright, T. [University of Manchester, Manchester (United Kingdom); Caamano, M.; Deo, K.; Duran, I.; Fernandez-Dominguez, B.; Leal-Cidoncha, E.; Paradela, C.; Robles, M.S. [University of Santiago de Compostela, Santiago de Compostela (Spain); Calvino, F.; Casanovas, A.; Riego-Perez, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Castelluccio, D.M.; Lo Meo, S. [Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (Italy); Cortes, G.; Mengoni, A. [Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna (Italy); Domingo-Pardo, C.; Tain, J.L. [Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Heinitz, S.; Kivel, N.; Maugeri, E.A.; Schumann, D. [Paul Scherrer Institut (PSI), Villingen (Switzerland); Furman, V.; Sedyshev, P. [Joint Institute for Nuclear Research (JINR), Dubna (Russian Federation); Gheorghe, I.; Glodariu, T.; Mirea, M.; Oprea, A. [Horia Hulubei National Institute of Physics and Nuclear Engineering, Magurele (Romania); Goverdovski, A.; Ketlerov, V.; Khryachkov, V. [Institute of Physics and Power Engineering (IPPE), Obninsk (Russian Federation); Griesmayer, E.; Jericha, E.; Kavrigin, P.; Leeb, H. [Technische Universitaet Wien, Wien (Austria); Harada, H.; Kimura, A. [Japan Atomic Energy Agency (JAEA), Tokai-mura (Japan); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Heyse, J.; Schillebeeckx, P. [European Commission, Joint Research Centre, Geel (BE); Jenkins, D.G. [University of York, York (GB); Kaeppeler, F. [Karlsruhe Institute of Technology, Karlsruhe (DE); Katabuchi, T. [Tokyo Institute of Technology, Tokyo (JP); Lederer, C.; Lonsdale, S.J.; Woods, P.J. [University of Edinburgh, School of Physics and Astronomy, Edinburgh (GB); Licata, M.; Massimi, C.; Vannini, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Universita di Bologna, Dipartimento di Fisica e Astronomia, Bologna (IT); Mastinu, P. [Istituto Nazionale di Fisica Nucleare, Sezione di Legnaro, Legnaro (IT); Matteucci, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste (IT); Universita di Trieste, Dipartimento di Astronomia, Trieste (IT); Mingrone, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Nolte, R. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (DE); Palomo-Pinto, F.R. [Universidad de Sevilla, Dept. Ingenieria Electronica, Escuela Tecnica Superior de Ingenieros, Sevilla (ES); Patronis, N. [University of Ioannina, Ioannina (GR); Pavlik, A. [University of Vienna, Faculty of Physics, Vienna (AT); Porras, J.I. [University of Granada, Granada (ES); Praena, J. [Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (ES); University of Granada, Granada (ES); Rajeev, K.; Rout, P.C.; Saxena, A.; Suryanarayana, S.V. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Rauscher, T. [University of Hertfordshire, Centre for Astrophysics Research, Hatfield (GB); University of Basel, Department of Physics, Basel (CH); Tarifeno-Saldivia, A. [Universitat Politecnica de Catalunya, Barcelona (ES); Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (ES); Ventura, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Wallner, A. [Australian National University, Canberra (AU)

    2017-10-15

    A new high flux experimental area has recently become operational at the nTOF facility at CERN. This new measuring station, nTOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20 m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutron-converting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2 meV to 100 MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the nTOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with {sup 197}Au foils in the beam. (orig.)

  15. High-accuracy determination of the neutron flux in the new experimental area n_TOF-EAR2 at CERN

    Science.gov (United States)

    Sabaté-Gilarte, M.; Barbagallo, M.; Colonna, N.; Gunsing, F.; Žugec, P.; Vlachoudis, V.; Chen, Y. H.; Stamatopoulos, A.; Lerendegui-Marco, J.; Cortés-Giraldo, M. A.; Villacorta, A.; Guerrero, C.; Damone, L.; Audouin, L.; Berthoumieux, E.; Cosentino, L.; Diakaki, M.; Finocchiaro, P.; Musumarra, A.; Papaevangelou, T.; Piscopo, M.; Tassan-Got, L.; Aberle, O.; Andrzejewski, J.; Bécares, V.; Bacak, M.; Baccomi, R.; Balibrea, J.; Barros, S.; Bečvář, F.; Beinrucker, C.; Belloni, F.; Billowes, J.; Bosnar, D.; Brugger, M.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Castelluccio, D. M.; Cerutti, F.; Chiaveri, E.; Cortés, G.; Deo, K.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Frost, R. J. W.; Furman, V.; Göbel, K.; García, A. R.; Gawlik, A.; Gheorghe, I.; Glodariu, T.; Gonçalves, I. F.; González, E.; Goverdovski, A.; Griesmayer, E.; Harada, H.; Heftrich, T.; Heinitz, S.; Hernández-Prieto, A.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Katabuchi, T.; Kavrigin, P.; Ketlerov, V.; Khryachkov, V.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Licata, M.; Lo Meo, S.; Lonsdale, S. J.; Losito, R.; Macina, D.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Matteucci, F.; Maugeri, E. A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Montesano, S.; Nolte, R.; Oprea, A.; Palomo-Pinto, F. R.; Paradela, C.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, J. I.; Praena, J.; Quesada, J. M.; Rajeev, K.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Robles, M. S.; Rout, P. C.; Rubbia, C.; Ryan, J. A.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Smith, A. G.; Suryanarayana, S. V.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlastou, R.; Wallner, A.; Warren, S.; Weigand, M.; Wolf, C.; Woods, P. J.; Weiss, C.; Wright, T.

    2017-10-01

    A new high flux experimental area has recently become operational at the n_TOF facility at CERN. This new measuring station, n_TOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutron-converting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2meV to 100MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the n_TOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with 197Au foils in the beam.

  16. High sensitivity and accuracy dissolved oxygen (DO) detection by using PtOEP/poly(MMA-co-TFEMA) sensing film

    Science.gov (United States)

    Zhang, Ke; Zhang, Honglin; Wang, Ying; Tian, Yanqing; Zhao, Jiupeng; Li, Yao

    2017-01-01

    Fluorinated acrylate polymer has received great interest in recent years due to its extraordinary characteristics such as high oxygen permeability, good stability, low surface energy and refractive index. In this work, platinum octaethylporphyrin/poly(methylmethacrylate-co-trifluoroethyl methacrylate) (PtOEP/poly(MMA-co-TFEMA)) oxygen sensing film was prepared by the immobilizing of PtOEP in a poly(MMA-co-TFEMA) matrix and the technological readiness of optical properties was established based on the principle of luminescence quenching. It was found that the oxygen-sensing performance could be improved by optimizing the monomer ratio (MMA/TFEMA = 1:1), tributylphosphate(TBP, 0.05 mL) and PtOEP (5 μg) content. Under this condition, the maximum quenching ratio I0/I100 of the oxygen sensing film is obtained to be about 8.16, Stern-Volmer equation is I0/I = 1.003 + 2.663[O2] (R2 = 0.999), exhibiting a linear relationship, good photo-stability, high sensitivity and accuracy. Finally, the synthesized PtOEP/poly(MMA-co-TFEMA) sensing film was used for DO detection in different water samples.

  17. The Accuracy of the CNAP® Device Compared with Invasive Radial Artery Measurements for Providing Continuous Noninvasive Arterial Blood Pressure Readings at a Medical Intensive Care Unit: A Method-Comparison Study.

    Science.gov (United States)

    Smolle, Karl-Heinz; Schmid, Martin; Prettenthaler, Helga; Weger, Christian

    2015-12-01

    In cases of intensive care unit (ICU) patients without an arterial line, noninvasive continuous blood pressure monitoring could be very beneficial. The CNAP® monitor (CNSystems Medizintechnik AG) provides noninvasive, beat-to-beat blood pressure (BP) estimates using the volume clamp method to measure finger arterial pressure calibrated to brachial pressure values. The aim of this study was to compare noninvasive BP estimates of the CNAP monitor with invasive blood pressure (IBP) measurements obtained via a radial arterial catheter in unselected medical ICU patients under routine clinical conditions. In 40 adult patients, IBP and noninvasive CNAP blood pressure (CBP) were measured simultaneously for 30 minutes. Bland-Altman analysis accounting for repeated measurements revealed accuracy and precision of CBP toward IBP. Percentage errors were calculated using the summary measures method and tested for interchangeability. Trending analysis was assessed using 4-quadrant plots and polar plots, whereby each reported statistical calculation used the sample size of n = 40 patients. A total of 7200 measurement pairs of CBP and IBP were analyzed. For mean arterial pressure, accuracy ± precision resulted in 4.6 ± 6.7 mm Hg (limits of agreement -8.7 to 17.8 mm Hg) with a percentage error of 6.77% (95% confidence interval [CI], 6.57%-6.97%). Trending analysis of 3-minute intervals showed a concordance rate of 94.6% (95% CI, 94.0%-95.2%; exclusion zone 10%) and a polar concordance rate of 99.50% (95% CI, 99.48%-99.52%) for changes lying within 10% limits. The CNAP device provided feasible estimates of BP in unselected medical ICU patients under routine clinical conditions. Mean arterial pressure met interchangeability criteria for accuracy toward radial arterial pressure, as well as for percentage error, and showed good trending capabilities according to the Critchley predefined criteria.

  18. Health-risk behaviors among high school athletes and preventive services provided during sports physicals.

    Science.gov (United States)

    Johnson, Karen E; McRee, Annie-Laurie

    2015-01-01

    Preparticipation examinations (PPEs), or sports physicals, present opportunities for health care providers to identify and discuss common adolescent health-risk behaviors. We sought to examine the prevalence of health-risk behaviors among high school athletes and the proportion of providers who address these behaviors during PPEs. For this descriptive study we used data from two statewide surveys: a survey of adolescents (n = 46,492) and a survey of nurse practitioners and physicians (n = 561). The most prevalent risk behaviors reported by student athletes were low levels of physical activity (70%), bullying perpetration (41%), and alcohol use (41%). Most providers (≥75%) addressed many common risk behaviors during PPEs but fewer addressed bullying, violence, and prescription drug use. Topics discussed differed by provider type and patient population. Many providers addressed critical threats to adolescent health during PPEs, but findings suggest potential disconnects between topics addressed during PPEs and behaviors of athletes. Copyright © 2015 National Association of Pediatric Nurse Practitioners. Published by Elsevier Inc. All rights reserved.

  19. Effect of Skin Cancer Training Provided to Maritime High School Students on Their Knowledge and Behaviour.

    Science.gov (United States)

    Sümen, Adem; Öncel, Selma

    2015-01-01

    This study was conducted with the purpose of evaluating the effect of skin cancer training provided to maritime high school students on their knowledge and behaviour. The study had a quasi-experimental design with pre-test and post-test intervention and control groups. Two maritime high schools located in the city of Antalya were included within the scope of the study between March and June 2013, covering a total of 567 students. While the knowledge mean scores of students regarding skin cancer and sun protection did not vary in the pre-test (6.2 ± 1.9) and post-test (6.8 ± 1.9) control group, the knowledge mean scores of students in the experimental group increased from 6.0 ± 2.3 to 10.6 ± 1.2 after the provided training. Some 25.4% of students in the experimental group had low knowledge level and 62.2% had medium knowledge level in the pre-test; whereas no students had low knowledge level and 94.3% had high knowledge level in the post-test. It was determined that tenth grade students, those who had previous knowledge on the subject, who considered themselves to be protecting from the sun better, had higher knowledge levels and their knowledge levels increased as the risk level increased. It was found that the provided training was effective and increased positively the knowledge, attitude and behaviour levels of students in the experimental group in terms of skin cancer and sun protection. Along with the provided training which started to form a lifestyle, appropriate attitudes and behaviours concerning skin cancer and sun protection could be brought to students who will work in outdoor spaces and are members of the maritime profession within the risk group.

  20. High accuracy mass spectrometry analysis as a tool to verify and improve gene annotation using Mycobacterium tuberculosis as an example

    Directory of Open Access Journals (Sweden)

    Prasad Swati

    2008-07-01

    Full Text Available Abstract Background While the genomic annotations of diverse lineages of the Mycobacterium tuberculosis complex are available, divergences between gene prediction methods are still a challenge for unbiased protein dataset generation. M. tuberculosis gene annotation is an example, where the most used datasets from two independent institutions (Sanger Institute and Institute of Genomic Research-TIGR differ up to 12% in the number of annotated open reading frames, and 46% of the genes contained in both annotations have different start codons. Such differences emphasize the importance of the identification of the sequence of protein products to validate each gene annotation including its sequence coding area. Results With this objective, we submitted a culture filtrate sample from M. tuberculosis to a high-accuracy LTQ-Orbitrap mass spectrometer analysis and applied refined N-terminal prediction to perform comparison of two gene annotations. From a total of 449 proteins identified from the MS data, we validated 35 tryptic peptides that were specific to one of the two datasets, representing 24 different proteins. From those, 5 proteins were only annotated in the Sanger database. In the remaining proteins, the observed differences were due to differences in annotation of transcriptional start sites. Conclusion Our results indicate that, even in a less complex sample likely to represent only 10% of the bacterial proteome, we were still able to detect major differences between different gene annotation approaches. This gives hope that high-throughput proteomics techniques can be used to improve and validate gene annotations, and in particular for verification of high-throughput, automatic gene annotations.

  1. High Accuracy Potential Energy Surface, Dipole Moment Surface, Rovibrational Energies and Line List Calculations for ^{14}NH_3

    Science.gov (United States)

    Coles, Phillip; Yurchenko, Sergei N.; Polyansky, Oleg; Kyuberis, Aleksandra; Ovsyannikov, Roman I.; Zobov, Nikolay Fedorovich; Tennyson, Jonathan

    2017-06-01

    We present a new spectroscopic potential energy surface (PES) for ^{14}NH_3, produced by refining a high accuracy ab initio PES to experimental energy levels taken predominantly from MARVEL. The PES reproduces 1722 matched J=0-8 experimental energies with a root-mean-square error of 0.035 cm-1 under 6000 cm^{-1} and 0.059 under 7200 cm^{-1}. In conjunction with a new DMS calculated using multi reference configuration interaction (MRCI) and H=aug-cc-pVQZ, N=aug-cc-pWCVQZ basis sets, an infrared (IR) line list has been computed which is suitable for use up to 2000 K. The line list is used to assign experimental lines in the 7500 - 10,500 cm^{-1} region and previously unassigned lines in HITRAN in the 6000-7000 cm^{-1} region. Oleg L. Polyansky, Roman I. Ovsyannikov, Aleksandra A. Kyuberis, Lorenzo Lodi, Jonathan Tennyson, Andrey Yachmenev, Sergei N. Yurchenko, Nikolai F. Zobov, J. Mol. Spec., 327 (2016) 21-30 Afaf R. Al Derzia, Tibor Furtenbacher, Jonathan Tennyson, Sergei N. Yurchenko, Attila G. Császár, J. Quant. Spectrosc. Rad. Trans., 161 (2015) 117-130

  2. High-Accuracy Self-Calibration for Smart, Optical Orbiting Payloads Integrated with Attitude and Position Determination.

    Science.gov (United States)

    Li, Jin; Xing, Fei; Chu, Daping; Liu, Zilong

    2016-07-27

    A high-accuracy space smart payload integrated with attitude and position (SSPIAP) is a new type of optical remote sensor that can autonomously complete image positioning. Inner orientation parameters (IOPs) are a prerequisite for image position determination of an SSPIAP. The calibration of IOPs significantly influences the precision of image position determination of SSPIAPs. IOPs can be precisely measured and calibrated in a laboratory. However, they may drift to a significant degree because of vibrations during complicated launches and on-orbit functioning. Therefore, laboratory calibration methods are not suitable for on-orbit functioning. We propose an on-orbit self-calibration method for SSPIAPs. Our method is based on an auto-collimating dichroic filter combined with a micro-electro-mechanical system (MEMS) point-source focal plane. A MEMS procedure is used to manufacture a light transceiver focal plane, which integrates with point light sources and a complementary metal oxide semiconductor (CMOS) sensor. A dichroic filter is used to fabricate an auto-collimation light reflection element. The dichroic filter and the MEMS point light sources focal plane are integrated into an SSPIAP so it can perform integrated self-calibration. Experiments show that our method can achieve micrometer-level precision, which is good enough to complete real-time calibration without temporal or spatial limitations.

  3. Accuracy of high-resolution computed tomography in revealing fallopian canal fracture of patients with traumatic facial paralysis.

    Science.gov (United States)

    Yan, Chun; He, Benhong; Wang, Xingzheng; Qin, Zhong; Li, Yefeng; Peng, Yongli

    2015-10-01

    To investigate accuracy of high-resolution computed tomography (HRCT) of temporal bone in revealing fallopian canal fracture among the patients with traumatic facial paralysis. HRCT of temporal bone with cross-sectional scanning and multi-planar reformation (MPR) was performed on 31 patients with traumatic facial paralysis, and fracture sites of fallopian canal revealed by HRCT were retrospectively analyzed and compared with surgical findings. HRCT of temporal bone showed fracture of fallopian canal at geniculate ganglion in 25 cases, at tympanic segment in 15 cases, at labyrinthine segment in 5 cases, at pyramid segment in 2 cases, and at mastoid segment in one case, while surgical findings revealed that fracture involved geniculate ganglion in 27 cases, labyrinthine segment in 5, tympanic segment in 19, pyramid segment in 12, and mastoid segment in 9; the sensitivity of HRCT of temporal bone to detect fracture at such sites was 88.9%, 100%, 52.6%, 16.7% and 11.1%, respectively, and the specificity was 96.0%, 100%, 66.7%, 100% and 100%, respectively. HRCT of temporal bone was able to accurately reveal fracture of fallopian canal at geniculate ganglion and labyrinthine segment in the vast majority cases, but severely underestimated fracture at pyramid segment and mastoid segment of fallopian canal. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. High-accuracy measurements of snow Bidirectional Reflectance Distribution Function at visible and NIR wavelengths – comparison with modelling results

    Directory of Open Access Journals (Sweden)

    M. Dumont

    2010-03-01

    Full Text Available High-accuracy measurements of snow Bidirectional Reflectance Distribution Function (BRDF were performed for four natural snow samples with a spectrogonio-radiometer in the 500–2600 nm wavelength range. These measurements are one of the first sets of direct snow BRDF values over a wide range of lighting and viewing geometry. They were compared to BRDF calculated with two optical models. Variations of the snow anisotropy factor with lighting geometry, wavelength and snow physical properties were investigated. Results show that at wavelengths with small penetration depth, scattering mainly occurs in the very top layers and the anisotropy factor is controlled by the phase function. In this condition, forward scattering peak or double scattering peak is observed. In contrast at shorter wavelengths, the penetration of the radiation is much deeper and the number of scattering events increases. The anisotropy factor is thus nearly constant and decreases at grazing observation angles. The whole dataset is available on demand from the corresponding author.

  5. The LLNL High Accuracy Volume Renderer for Unstructured Data: Capabilities, Current Limits, and Potential for ASCI/VIEWS Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Williams, P L; Max, N L

    2001-06-04

    This report describes a volume rendering system for unstructured data, especially finite element data, that creates images with very high accuracy. The system will currently handle meshes whose cells are either linear or quadratic tetrahedra, or meshes with mixed cell types: tetrahedra, bricks, prisms, and pyramids. The cells may have nonplanar facets. Whenever possible, exact mathematical solutions for the radiance integrals and for interpolation are used. Accurate semitransparent shaded isosurfaces may be embedded in the volume rendering. For very small cells, subpixel accumulation by splatting is used to avoid sampling error. A new exact and efficient visibility ordering algorithm is described. The most accurate images are generated in software, however, more efficient algorithms utilizing graphics hardware may also be selected. The report describes the parallelization of the system for a distributed-shared memory multiprocessor machine, and concludes by discussing the system's limits, desirable future work, and ways to extend the system so as to be compatible with projected ASCI/VIEWS architectures.

  6. Linear Discriminant Analysis Achieves High Classification Accuracy for the BOLD fMRI Response to Naturalistic Movie Stimuli

    Science.gov (United States)

    Mandelkow, Hendrik; de Zwart, Jacco A.; Duyn, Jeff H.

    2016-01-01

    Naturalistic stimuli like movies evoke complex perceptual processes, which are of great interest in the study of human cognition by functional MRI (fMRI). However, conventional fMRI analysis based on statistical parametric mapping (SPM) and the general linear model (GLM) is hampered by a lack of accurate parametric models of the BOLD response to complex stimuli. In this situation, statistical machine-learning methods, a.k.a. multivariate pattern analysis (MVPA), have received growing attention for their ability to generate stimulus response models in a data-driven fashion. However, machine-learning methods typically require large amounts of training data as well as computational resources. In the past, this has largely limited their application to fMRI experiments involving small sets of stimulus categories and small regions of interest in the brain. By contrast, the present study compares several classification algorithms known as Nearest Neighbor (NN), Gaussian Naïve Bayes (GNB), and (regularized) Linear Discriminant Analysis (LDA) in terms of their classification accuracy in discriminating the global fMRI response patterns evoked by a large number of naturalistic visual stimuli presented as a movie. Results show that LDA regularized by principal component analysis (PCA) achieved high classification accuracies, above 90% on average for single fMRI volumes acquired 2 s apart during a 300 s movie (chance level 0.7% = 2 s/300 s). The largest source of classification errors were autocorrelations in the BOLD signal compounded by the similarity of consecutive stimuli. All classifiers performed best when given input features from a large region of interest comprising around 25% of the voxels that responded significantly to the visual stimulus. Consistent with this, the most informative principal components represented widespread distributions of co-activated brain regions that were similar between subjects and may represent functional networks. In light of these

  7. Linear Discriminant Analysis Achieves High Classification Accuracy for the BOLD fMRI Response to Naturalistic Movie Stimuli.

    Science.gov (United States)

    Mandelkow, Hendrik; de Zwart, Jacco A; Duyn, Jeff H

    2016-01-01

    Naturalistic stimuli like movies evoke complex perceptual processes, which are of great interest in the study of human cognition by functional MRI (fMRI). However, conventional fMRI analysis based on statistical parametric mapping (SPM) and the general linear model (GLM) is hampered by a lack of accurate parametric models of the BOLD response to complex stimuli. In this situation, statistical machine-learning methods, a.k.a. multivariate pattern analysis (MVPA), have received growing attention for their ability to generate stimulus response models in a data-driven fashion. However, machine-learning methods typically require large amounts of training data as well as computational resources. In the past, this has largely limited their application to fMRI experiments involving small sets of stimulus categories and small regions of interest in the brain. By contrast, the present study compares several classification algorithms known as Nearest Neighbor (NN), Gaussian Naïve Bayes (GNB), and (regularized) Linear Discriminant Analysis (LDA) in terms of their classification accuracy in discriminating the global fMRI response patterns evoked by a large number of naturalistic visual stimuli presented as a movie. Results show that LDA regularized by principal component analysis (PCA) achieved high classification accuracies, above 90% on average for single fMRI volumes acquired 2 s apart during a 300 s movie (chance level 0.7% = 2 s/300 s). The largest source of classification errors were autocorrelations in the BOLD signal compounded by the similarity of consecutive stimuli. All classifiers performed best when given input features from a large region of interest comprising around 25% of the voxels that responded significantly to the visual stimulus. Consistent with this, the most informative principal components represented widespread distributions of co-activated brain regions that were similar between subjects and may represent functional networks. In light of these

  8. Linear Discriminant Analysis achieves high classification accuracy for the BOLD fMRI response to naturalistic movie stimuli.

    Directory of Open Access Journals (Sweden)

    Hendrik eMandelkow

    2016-03-01

    Full Text Available Naturalistic stimuli like movies evoke complex perceptual processes, which are of great interest in the study of human cognition by functional MRI (fMRI. However, conventional fMRI analysis based on statistical parametric mapping (SPM and the general linear model (GLM is hampered by a lack of accurate parametric models of the BOLD response to complex stimuli. In this situation, statistical machine-learning methods, a.k.a. multivariate pattern analysis (MVPA, have received growing attention for their ability to generate stimulus response models in a data-driven fashion. However, machine-learning methods typically require large amounts of training data as well as computational resources. In the past this has largely limited their application to fMRI experiments involving small sets of stimulus categories and small regions of interest in the brain. By contrast, the present study compares several classification algorithms known as Nearest Neighbour (NN, Gaussian Naïve Bayes (GNB, and (regularised Linear Discriminant Analysis (LDA in terms of their classification accuracy in discriminating the global fMRI response patterns evoked by a large number of naturalistic visual stimuli presented as a movie.Results show that LDA regularised by principal component analysis (PCA achieved high classification accuracies, above 90% on average for single fMRI volumes acquired 2s apart during a 300s movie (chance level 0.7% = 2s/300s. The largest source of classification errors were autocorrelations in the BOLD signal compounded by the similarity of consecutive stimuli. All classifiers performed best when given input features from a large region of interest comprising around 25% of the voxels that responded significantly to the visual stimulus. Consistent with this, the most informative principal components represented widespread distributions of co-activated brain regions that were similar between subjects and may represent functional networks. In light of these

  9. A model program: neonatal nurse practitioners providing community health care for high-risk infants.

    Science.gov (United States)

    Vasquez, Elias Provencio; Pitts, Kathleen; Mejia, Nilson Enrique

    2008-01-01

    Perinatal drug exposure costs our communities millions of dollars each year in hospital fees and in services such as foster care, child protection, and drug treatment. Infants and their families in this group require substantial long-term health care and community resources. Neonatal health care providers should take an active role in developing and implementing home visitation programs to support early hospital discharge and continuity of care for these high-risk infants and their families. Neonatal nurse practitioners should prepare in the future to practice not only in secondary-- and tertiary--level neonatal centers, but also in follow-up clinics, long-term developmental centers, and the community This article describes a home intervention program delivered by neonatal nurse practitioners for high-risk infants and their mothers. The target population is infants exposed prenatally to drugs and/or alcohol.

  10. Perils of providing visual health information overviews for consumers with low health literacy or high stress

    Science.gov (United States)

    Miller, Trudi

    2010-01-01

    This pilot study explores the impact of a health topics overview (HTO) on reading comprehension. The HTO is generated automatically based on the presence of Unified Medical Language System terms. In a controlled setting, we presented health texts and posed 15 questions for each. We compared performance with and without the HTO. The answers were available in the text, but not always in the HTO. Our study (n=48) showed that consumers with low health literacy or high stress performed poorly when the HTO was available without linking directly to the answer. They performed better with direct links in the HTO or when the HTO was not available at all. Consumers with high health literacy or low stress performed better regardless of the availability of the HTO. Our data suggests that vulnerable consumers relied solely on the HTO when it was available and were misled when it did not provide the answer. PMID:20190068

  11. High Accuracy Microwave Frequency Measurement Based on Single-Drive Dual-Parallel Mach-Zehnder Modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Deng, Lei; Pang, Xiaodan

    2011-01-01

    A novel approach for broadband microwave frequency measurement based on bias manipulation of a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. A 10-3 relative error verifies a significant accuracy improvement by this method....

  12. Generation of a high-accuracy regional DEM based on ALOS/PRISM imagery of East Antarctica

    Science.gov (United States)

    Shiramizu, Kaoru; Doi, Koichiro; Aoyama, Yuichi

    2017-12-01

    A digital elevation model (DEM) is used to estimate ice-flow velocities for an ice sheet and glaciers via Differential Interferometric Synthetic Aperture Radar (DInSAR) processing. The accuracy of DInSAR-derived displacement estimates depends upon the accuracy of the DEM. Therefore, we used stereo optical images, obtained with a panchromatic remote-sensing instrument for stereo mapping (PRISM) sensor mounted onboard the Advanced Land Observing Satellite (ALOS), to produce a new DEM ("PRISM-DEM") of part of the coastal region of Lützow-Holm Bay in Dronning Maud Land, East Antarctica. We verified the accuracy of the PRISM-DEM by comparing ellipsoidal heights with those of existing DEMs and values obtained by satellite laser altimetry (ICESat/GLAS) and Global Navigation Satellite System surveying. The accuracy of the PRISM-DEM is estimated to be 2.80 m over ice sheet, 4.86 m over individual glaciers, and 6.63 m over rock outcrops. By comparison, the estimated accuracy of the ASTER-GDEM, widely used in polar regions, is 33.45 m over ice sheet, 14.61 m over glaciers, and 19.95 m over rock outcrops. For displacement measurements made along the radar line-of-sight by DInSAR, in conjunction with ALOS/PALSAR data, the accuracy of the PRISM-DEM and ASTER-GDEM correspond to estimation errors of <6.3 mm and <31.8 mm, respectively.

  13. An evaluation of the accuracy and precision of methane prediction equations for beef cattle fed high-forage and high-grain diets.

    Science.gov (United States)

    Escobar-Bahamondes, P; Oba, M; Beauchemin, K A

    2017-01-01

    The study determined the performance of equations to predict enteric methane (CH4) from beef cattle fed forage- and grain-based diets. Many equations are available to predict CH4 from beef cattle and the predictions vary substantially among equations. The aims were to (1) construct a database of CH4 emissions for beef cattle from published literature, and (2) identify the most precise and accurate extant CH4 prediction models for beef cattle fed diets varying in forage content. The database was comprised of treatment means of CH4 production from in vivo beef studies published from 2000 to 2015. Criteria to include data in the database were as follows: animal description, intakes, diet composition and CH4 production. In all, 54 published equations that predict CH4 production from diet composition were evaluated. Precision and accuracy of the equations were evaluated using the concordance correlation coefficient (r c ), root mean square prediction error (RMSPE), model efficiency and analysis of errors. Equations were ranked using a combined index of the various statistical assessments based on principal component analysis. The final database contained 53 studies and 207 treatment means that were divided into two data sets: diets containing ⩾400 g/kg dry matter (DM) forage (n=116) and diets containing ⩽200 g/kg DM forage (n=42). Diets containing between ⩽400 and ⩾200 g/kg DM forage were not included in the analysis because of their limited numbers (n=6). Outliers, treatment means where feed was fed restrictively and diets with CH4 mitigation additives were omitted (n=43). Using the high-forage dataset the best-fit equations were the International Panel on Climate Change Tier 2 method, 3 equations for steers that considered gross energy intake (GEI) and body weight and an equation that considered dry matter intake and starch:neutral detergent fiber with r c ranging from 0.60 to 0.73 and RMSPE from 35.6 to 45.9 g/day. For the high-grain diets, the 5 best

  14. Defining the essential anatomical coverage provided by military body armour against high energy projectiles.

    Science.gov (United States)

    Breeze, John; Lewis, E A; Fryer, R; Hepper, A E; Mahoney, Peter F; Clasper, Jon C

    2016-08-01

    Body armour is a type of equipment worn by military personnel that aims to prevent or reduce the damage caused by ballistic projectiles to structures within the thorax and abdomen. Such injuries remain the leading cause of potentially survivable deaths on the modern battlefield. Recent developments in computer modelling in conjunction with a programme to procure the next generation of UK military body armour has provided the impetus to re-evaluate the optimal anatomical coverage provided by military body armour against high energy projectiles. A systematic review of the literature was undertaken to identify those anatomical structures within the thorax and abdomen that if damaged were highly likely to result in death or significant long-term morbidity. These structures were superimposed upon two designs of ceramic plate used within representative body armour systems using a computerised representation of human anatomy. Those structures requiring essential medical coverage by a plate were demonstrated to be the heart, great vessels, liver and spleen. For the 50th centile male anthropometric model used in this study, the front and rear plates from the Enhanced Combat Body Armour system only provide limited coverage, but do fulfil their original requirement. The plates from the current Mark 4a OSPREY system cover all of the structures identified in this study as requiring coverage except for the abdominal sections of the aorta and inferior vena cava. Further work on sizing of plates is recommended due to its potential to optimise essential medical coverage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Providing high-quality care in primary care settings: how to make trade-offs.

    Science.gov (United States)

    Beaulieu, Marie-Dominique; Geneau, Robert; Del Grande, Claudio; Denis, Jean-Louis; Hudon, Eveline; Haggerty, Jeannie L; Bonin, Lucie; Duplain, Réjean; Goudreau, Johanne; Hogg, William

    2014-05-01

    To gain a deeper understanding of how primary care (PC) practices belonging to different models manage resources to provide high-quality care. Multiple-case study embedded in a cross-sectional study of a random sample of 37 practices. Three regions of Quebec. Health care professionals and staff of 5 PC practices. Five cases showing above-average results on quality-of-care indicators were purposefully selected to contrast on region, practice size, and PC model. Data were collected using an organizational questionnaire; the Team Climate Inventory, which was completed by health care professionals and staff; and 33 individual interviews. Detailed case histories were written and thematic analysis was performed. The core common feature of these practices was their ongoing effort to make trade-offs to deliver services that met their vision of high-quality care. These compromises involved the same 3 areas, but to varying degrees depending on clinic characteristics: developing a shared vision of high-quality care; aligning resource use with that vision; and balancing professional aspirations and population needs. The leadership of the physician lead was crucial. The external environment was perceived as a source of pressure and dilemmas rather than as a source of support in these matters. Irrespective of their models, PC practices' pursuit of high-quality care is based on a vision in which accessibility is a key component, balanced by appropriate management of available resources and of external environment expectations. Current PC reforms often create tensions rather than support PC practices in their pursuit of high-quality care. Copyright© the College of Family Physicians of Canada.

  16. Epidemiology of tuberculosis in a high HIV prevalence population provided with enhanced diagnosis of symptomatic disease.

    Directory of Open Access Journals (Sweden)

    Elizabeth L Corbett

    2007-01-01

    Full Text Available Directly observed treatment short course (DOTS, the global control strategy aimed at controlling tuberculosis (TB transmission through prompt diagnosis of symptomatic smear-positive disease, has failed to prevent rising tuberculosis incidence rates in Africa brought about by the HIV epidemic. However, rising incidence does not necessarily imply failure to control tuberculosis transmission, which is primarily driven by prevalent infectious disease. We investigated the epidemiology of prevalent and incident TB in a high HIV prevalence population provided with enhanced primary health care.Twenty-two businesses in Harare, Zimbabwe, were provided with free smear- and culture-based investigation of TB symptoms through occupational clinics. Anonymised HIV tests were requested from all employees. After 2 y of follow-up for incident TB, a culture-based survey for undiagnosed prevalent TB was conducted. A total of 6,440 of 7,478 eligible employees participated. HIV prevalence was 19%. For HIV-positive and -negative participants, the incidence of culture-positive tuberculosis was 25.3 and 1.3 per 1,000 person-years, respectively (adjusted incidence rate ratio = 18.8; 95% confidence interval [CI] = 10.3 to 34.5: population attributable fraction = 78%, and point prevalence after 2 y was 5.7 and 2.6 per 1,000 population (adjusted odds ratio = 1.7; 95% CI = 0.5 to 6.8: population attributable fraction = 14%. Most patients with prevalent culture-positive TB had subclinical disease when first detected.Strategies based on prompt investigation of TB symptoms, such as DOTS, may be an effective way of controlling prevalent TB in high HIV prevalence populations. This may translate into effective control of TB transmission despite high TB incidence rates and a period of subclinical infectiousness in some patients.

  17. A high accuracy femto-/picosecond laser damage test facility dedicated to the study of optical thin films

    Science.gov (United States)

    Mangote, B.; Gallais, L.; Zerrad, M.; Lemarchand, F.; Gao, L. H.; Commandré, M.; Lequime, M.

    2012-01-01

    A laser damage test facility delivering pulses from 100 fs to 3 ps and designed to operate at 1030 nm is presented. The different details of its implementation and performances are given. The originality of this system relies the online damage detection system based on Nomarski microscopy and the use of a non-conventional energy detection method based on the utilization of a cooled CCD that offers the possibility to obtain the laser induced damage threshold (LIDT) with high accuracy. Applications of this instrument to study thin films under laser irradiation are presented. Particularly the deterministic behavior of the sub-picosecond damage is investigated in the case of fused silica and oxide films. It is demonstrated that the transition of 0-1 damage probability is very sharp and the LIDT is perfectly deterministic at few hundreds of femtoseconds. The damage process in dielectric materials being the results of electronic processes, specific information such as the material bandgap is needed for the interpretation of results and applications of scaling laws. A review of the different approaches for the estimation of the absorption gap of optical dielectric coatings is conducted and the results given by the different methods are compared and discussed. The LIDT and gap of several oxide materials are then measured with the presented instrument: Al2O3, Nb2O5, HfO2, SiO2, Ta2O5, and ZrO2. The obtained relation between the LIDT and gap at 1030 nm confirms the linear evolution of the threshold with the bandgap that exists at 800 nm, and our work expands the number of tested materials.

  18. Diagnostic accuracy of specific IgE antibodies measurements in occupational airway allergy to high molecular weight agents

    Directory of Open Access Journals (Sweden)

    Joanna Zgorzelska-Kowalik

    2017-02-01

    Full Text Available Background: The performance of specific inhalation challenge test (SICT – reference method in diagnostics of occupational allergy – has some limitations due to health status of a particular patient. Therefore, it is extremely important to identify usefulness of other tests, and the evaluation of diagnostic accuracy of commercially available serum specific immunoglobulin E (sIgE kits to the most common high molecular weight agents has been launched. Material and Methods: The study group comprised 141 subjects – 110 bakers and 31 farmers – with suspicion of occupational airway allergy. All patients underwent evaluation of serum sIgE to occupational allergens with the use of Phadia and Allergopharma kits: in bakers to flour mix and α-amylase, in farmers to epithelium of cow, pig and feathers. Specific inhalation challenge test with workplace allergens performed in all subjects was a reference method for further analysis. Results: Serum specific IgE to flour mix had the highest sensitivity (Phadia – 95.6%, Allergopharma – 88.3%, while its specificity was relatively low (Phadia – 47.8%, Allergopharma – 25%. There were numerous discrepancies between the results of sIgE estimation for particular single allergens (k87, e4, e83, as well as for their mixtures (fx901, fx20, ex71, performed with the kits of both companies (Phadia vs. Allergopharma. Conclusions: Evaluation of serum specific IgE is characterized by inadequate sensitivity, specificity and predictive value to take the place of specific inhalation challenge test in diagnostics of occupational respiratory allergy. Med Pr 2017;68(1:31–43

  19. Anti-aliasing filters for deriving high-accuracy DEMs from TLS data: A case study from Freeport, Texas

    Science.gov (United States)

    Xiong, Lin.; Wang, Guoquan; Wessel, Paul

    2017-03-01

    Terrestrial laser scanning (TLS), also known as ground-based Light Detection and Ranging (LiDAR), has been frequently applied to build bare-earth digital elevation models (DEMs) for high-accuracy geomorphology studies. The point clouds acquired from TLS often achieve a spatial resolution at fingerprint (e.g., 3 cm×3 cm) to handprint (e.g., 10 cm×10 cm) level. A downsampling process has to be applied to decimate the massive point clouds and obtain manageable DEMs. It is well known that downsampling can result in aliasing that causes different signal components to become indistinguishable when the signal is reconstructed from the datasets with a lower sampling rate. Conventional DEMs are mainly the results of upsampling of sparse elevation measurements from land surveying, satellite remote sensing, and aerial photography. As a consequence, the effects of aliasing caused by downsampling have not been fully investigated in the open literature of DEMs. This study aims to investigate the spatial aliasing problem of regridding dense TLS data. The TLS data collected from the beach and dune area near Freeport, Texas in the summer of 2015 are used for this study. The core idea of the anti-aliasing procedure is to apply a low-pass spatial filter prior to conducting downsampling. This article describes the successful use of a fourth-order Butterworth low-pass spatial filter employed in the Generic Mapping Tools (GMT) software package as an anti-aliasing filter. The filter can be applied as an isotropic filter with a single cutoff wavelength or as an anisotropic filter with two different cutoff wavelengths in the X and Y directions. The cutoff wavelength for the isotropic filter is recommended to be three times the grid size of the target DEM.

  20. Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease.

    Science.gov (United States)

    Nie, Pei; Wang, Ximing; Cheng, Zhaoping; Ji, Xiaopeng; Duan, Yanhua; Chen, Jiuhong

    2012-10-01

    To compare accuracy, image quality and radiation dose between high-pitch spiral and sequential modes on 128-slice dual-source computed tomographic (DSCT) angiography in children with congenital heart disease (CHD). Forty patients suspected with CHD underwent 128-slice DSCT angiography with high-pitch mode and sequential mode respectively. All the anomalies were confirmed by the surgical and/or the conventional cardiac angiography (CCA) findings. The diagnostic accuracy, the subjective and objective image quality and effective radiation doses were compared. There was no significant difference in diagnostic accuracy (χ ( 2 ) = 0.963, P > 0.05), the objective parameters for image quality (P > 0.05) and the image quality of great vessels (u = 167.500, P > 0.05) between the two groups. The image quality of intracardiac structures and coronary arteries was significantly better in the sequential mode group than that in the high-pitch group (u = 112.500 and 100.000, P < 0.05). The mean effective dose in high-pitch group (0.17 ± 0.05 mSv) was significantly lower (t = 5.287, P < 0.05) than that in the sequential mode group (0.29 ± 0.09 mSv). Both the high-pitch and the sequential modes for 128-slice DSCT angiography provide high accuracy for the assessment of CHD in children, while the high-pitch mode, even with some image quality decrease, further significantly lowers the radiation dose. • Modern CT provides excellent anatomical detail of congenital heart disease. • Dual source CT systems offer high-pitch spiral and sequential modes. • The high-pitch mode provides high accuracy for the assessment of CHD. • A few images using the high-pitch mode were occasionally slightly degraded. • But the high-pitch mode significantly lowers the radiation dose.

  1. Sports Cardiology: Core Curriculum for Providing Cardiovascular Care to Competitive Athletes and Highly Active People.

    Science.gov (United States)

    Baggish, Aaron L; Battle, Robert W; Beckerman, James G; Bove, Alfred A; Lampert, Rachel J; Levine, Benjamin D; Link, Mark S; Martinez, Matthew W; Molossi, Silvana M; Salerno, Jack; Wasfy, Meagan M; Weiner, Rory B; Emery, Michael S

    2017-10-10

    The last few decades have seen substantial growth in the populations of competitive athletes and highly active people (CAHAP). Although vigorous physical exercise is an effective way to reduce the risk of cardiovascular (CV) disease, CAHAP remain susceptible to inherited and acquired CV disease, and may be most at risk for adverse CV outcomes during intense physical activity. Traditionally, multidisciplinary teams comprising athletic trainers, physical therapists, primary care sports medicine physicians, and orthopedic surgeons have provided clinical care for CAHAP. However, there is increasing recognition that a care team including qualified CV specialists optimizes care delivery for CAHAP. In recognition of the increasing demand for CV specialists competent in the care of CAHAP, the American College of Cardiology has recently established a Sports and Exercise Council. An important primary objective of this council is to define the essential skills necessary to practice effective sports cardiology. Copyright © 2017. Published by Elsevier Inc.

  2. CESAME: Providing High Quality Professional Development in Science and Mathematics for K-12 Teachers

    Science.gov (United States)

    Hickman, Paul

    2002-04-01

    It is appropriate that after almost half a century of Science and Mathematics education reform we take a look back and a peek forward to understand the present state of this wonderfully complex system. Each of the components of this system including teaching, professional development, assessment, content and the district K-12 curriculum all need to work together if we hope to provide quality science, mathematics and technology education for ALL students. How do the state and national standards drive the system? How do state policies on student testing and teacher licensure come into play? How do we improve the preparation, retention and job satisfaction of our K-12 teachers? What initiatives have made or are making a difference? What else needs to be done? What can the physics community do to support local efforts? This job is too big for any single organization or individual but we each can contribute to the effort. Our Center at Northeastern University, with support from the National Science Foundation, has a sharply defined focus: to get high quality, research-based instructional materials into the hands of K-12 classroom teachers and provide the support they need to use the materials effectively in their classrooms.

  3. Can high resolution 3D topographic surveys provide reliable grain size estimates in gravel bed rivers?

    Science.gov (United States)

    Pearson, E.; Smith, M. W.; Klaar, M. J.; Brown, L. E.

    2017-09-01

    High resolution topographic surveys such as those provided by Structure-from-Motion (SfM) contain a wealth of information that is not always exploited in the generation of Digital Elevation Models (DEMs). In particular, several authors have related sub-metre scale topographic variability (or 'surface roughness') to sediment grain size by deriving empirical relationships between the two. In fluvial applications, such relationships permit rapid analysis of the spatial distribution of grain size over entire river reaches, providing improved data to drive three-dimensional hydraulic models, allowing rapid geomorphic monitoring of sub-reach river restoration projects, and enabling more robust characterisation of riverbed habitats. However, comparison of previously published roughness-grain-size relationships shows substantial variability between field sites. Using a combination of over 300 laboratory and field-based SfM surveys, we demonstrate the influence of inherent survey error, irregularity of natural gravels, particle shape, grain packing structure, sorting, and form roughness on roughness-grain-size relationships. Roughness analysis from SfM datasets can accurately predict the diameter of smooth hemispheres, though natural, irregular gravels result in a higher roughness value for a given diameter and different grain shapes yield different relationships. A suite of empirical relationships is presented as a decision tree which improves predictions of grain size. By accounting for differences in patch facies, large improvements in D50 prediction are possible. SfM is capable of providing accurate grain size estimates, although further refinement is needed for poorly sorted gravel patches, for which c-axis percentiles are better predicted than b-axis percentiles.

  4. Strategy for high-accuracy-and-precision retrieval of atmospheric methane from the mid-infrared FTIR network

    Directory of Open Access Journals (Sweden)

    R. Sussmann

    2011-09-01

    Full Text Available We present a strategy (MIR-GBM v1.0 for the retrieval of column-averaged dry-air mole fractions of methane (XCH4 with a precision <0.3% (1-σ diurnal variation, 7-min integration and a seasonal bias <0.14% from mid-infrared ground-based solar FTIR measurements of the Network for the Detection of Atmospheric Composition Change (NDACC, comprising 22 FTIR stations. This makes NDACC methane data useful for satellite validation and for the inversion of regional-scale sources and sinks in addition to long-term trend analysis. Such retrievals complement the high accuracy and precision near-infrared observations of the younger Total Carbon Column Observing Network (TCCON with time series dating back 15 years or so before TCCON operations began.

    MIR-GBM v1.0 is using HITRAN 2000 (including the 2001 update release and 3 spectral micro windows (2613.70–2615.40 cm−1, 2835.50–2835.80 cm−1, 2921.00–2921.60 cm−1. A first-order Tikhonov constraint is applied to the state vector given in units of per cent of volume mixing ratio. It is tuned to achieve minimum diurnal variation without damping seasonality. Final quality selection of the retrievals uses a threshold for the goodness of fit (χ2 < 1 as well as for the ratio of root-mean-square spectral noise and information content (<0.15%. Column-averaged dry-air mole fractions are calculated using the retrieved methane profiles and four-times-daily pressure-temperature-humidity profiles from National Center for Environmental Prediction (NCEP interpolated to the time of measurement.

    MIR-GBM v1.0 is the optimum of 24 tested retrieval strategies (8 different spectral micro-window selections, 3 spectroscopic line lists: HITRAN 2000, 2004, 2008. Dominant errors of the non-optimum retrieval strategies are systematic HDO/H2O-CH4 interference errors leading to a seasonal bias up to ≈5%. Therefore interference

  5. Using ProSight PTM and related tools for targeted protein identification and characterization with high mass accuracy tandem MS data.

    Science.gov (United States)

    Leduc, Richard D; Kelleher, Neil L

    2007-09-01

    ProSight PTM v2.0, neuroProSight, and the Sequence Gazer allow the identification and characterization of proteins from high mass accuracy tandem mass spectrometric data of intact proteins and large peptides. Input data consists of one or more neutral precursor ion masses and a set of neutral b/y or c/z(.) fragment ions masses. This data is compared against "shotgun annotated" proteome databases or known protein sequences. With these tools it is possible to not only identify unknown proteins, but to determine the location of post-translational modifications (PTM) with 100% sequence coverage. Collectively, the tools create a search environment that allows five different search modes, including absolute mass and sequence tag searching, which are conveniently employed via a graphical user interface. Data management and chemical noise reduction tools are also available. These tools provide a complete environment for the identification and characterization of proteins from high resolution tandem mass spectrometry of intact proteins and large peptides. Copyright 2007 by John Wiley & Sons, Inc.

  6. High-accuracy and high-sensitivity spectroscopic measurement of dinitrogen pentoxide (N2O5) in an atmospheric simulation chamber using a quantum cascade laser.

    Science.gov (United States)

    Yi, Hongming; Wu, Tao; Lauraguais, Amélie; Semenov, Vladimir; Coeur, Cecile; Cassez, Andy; Fertein, Eric; Gao, Xiaoming; Chen, Weidong

    2017-09-15

    A spectroscopic instrument based on a mid-infrared external cavity quantum cascade laser (EC-QCL) was developed for high-accuracy measurements of dinitrogen pentoxide (N2O5) at the ppbv-level. A specific concentration retrieval algorithm was developed to remove, from the broadband absorption spectrum of N2O5, both etalon fringes resulting from the EC-QCL intrinsic structure and spectral interference lines of H2O vapour absorption, which led to a significant improvement in measurement accuracy and detection sensitivity (by a factor of 10), compared to using a traditional algorithm for gas concentration retrieval. The developed EC-QCL-based N2O5 sensing platform was evaluated by real-time tracking N2O5 concentration in its most important nocturnal tropospheric chemical reaction of NO3 + NO2 ↔ N2O5 in an atmospheric simulation chamber. Based on an optical absorption path-length of Leff = 70 m, a minimum detection limit of 15 ppbv was achieved with a 25 s integration time and it was down to 3 ppbv in 400 s. The equilibrium rate constant Keq involved in the above chemical reaction was determined with direct concentration measurements using the developed EC-QCL sensing platform, which was in good agreement with the theoretical value deduced from a referenced empirical formula under well controlled experimental conditions. The present work demonstrates the potential and the unique advantage of the use of a modern external cavity quantum cascade laser for applications in direct quantitative measurement of broadband absorption of key molecular species involved in chemical kinetic and climate-change related tropospheric chemistry.

  7. Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

    Science.gov (United States)

    Mason, Lee S.

    2003-01-01

    Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU

  8. The accuracy of Patient Health Questionnaire-9 in detecting depression and measuring depression severity in high-risk groups in primary care.

    NARCIS (Netherlands)

    Wittkampf, K.; Ravesteijn, H.J. van; Baas, K.; Hoogen, H.J.M. van den; Schene, A.; Bindels, P.; Lucassen, P.L.B.J.; Lisdonk, E.H. van de; Weert, H. van

    2009-01-01

    OBJECTIVE: Only half of patients with depressive disorder are diagnosed by their family physicians. Screening in high-risk groups might reduce this hidden morbidity. This study aims to determine the accuracy of the Patient Health Questionnaire-9 (PHQ-9) in (a) screening for depressive disorder, (b)

  9. High Accuracy Radiation TSP-type Thermometers for Radiometric Scale Realization in the Temperature Range from 600 to 3200 °C

    Science.gov (United States)

    Samoylov, M. L.; Ogarev, S. A.; Khlevnoy, B. B.; Khromchenko, V. B.; Mekhontsev, S. N.; Sapritsky, V. I.

    2003-09-01

    We have designed at VNIIOFI a high-accuracy radiation thermometer, model TSP-2 (Transfer Standard Pyrometer), for radiometric scale dissemination within the temperature range from 600°C to 3200 °C. This thermometer has been recently modified and investigated. The new TSP-4 model of radiation thermometer is under development now.

  10. Plant Growth under Natural Light Conditions Provides Highly Flexible Short-Term Acclimation Properties toward High Light Stress

    Science.gov (United States)

    Schumann, Tobias; Paul, Suman; Melzer, Michael; Dörmann, Peter; Jahns, Peter

    2017-01-01

    Efficient acclimation to different growth light intensities is essential for plant fitness. So far, most studies on light acclimation have been conducted with plants grown under different constant light regimes, but more recent work indicated that acclimation to fluctuating light or field conditions may result in different physiological properties of plants. Thale cress (Arabidopsis thaliana) was grown under three different constant light intensities (LL: 25 μmol photons m−2 s−1; NL: 100 μmol photons m−2 s−1; HL: 500 μmol photons m−2 s−1) and under natural fluctuating light (NatL) conditions. We performed a thorough characterization of the morphological, physiological, and biochemical properties focusing on photo-protective mechanisms. Our analyses corroborated the known properties of LL, NL, and HL plants. NatL plants, however, were found to combine characteristics of both LL and HL grown plants, leading to efficient and unique light utilization capacities. Strikingly, the high energy dissipation capacity of NatL plants correlated with increased dynamics of thylakoid membrane reorganization upon short-term acclimation to excess light. We conclude that the thylakoid membrane organization and particularly the light-dependent and reversible unstacking of grana membranes likely represent key factors that provide the basis for the high acclimation capacity of NatL grown plants to rapidly changing light intensities. PMID:28515734

  11. Block periodization of high-intensity aerobic intervals provides superior training effects in trained cyclists.

    Science.gov (United States)

    Rønnestad, B R; Hansen, J; Ellefsen, S

    2014-02-01

    The purpose of this study was to compare the effect of two different methods of organizing endurance training in trained cyclists. One group of cyclists performed block periodization, wherein the first week constituted five sessions of high-intensity aerobic training (HIT), followed by 3 weeks of one weekly HIT session and focus on low-intensity training (LIT) (BP; n = 10, VO2max  = 62 ± 2 mL/kg/min). Another group of cyclists performed a more traditional organization, with 4 weeks of two weekly HIT sessions interspersed with LIT (TRAD; n = 9, VO2max  = 63 ± 2 mL/kg/min). Similar volumes of both HIT and LIT was performed in the two groups. While BP increased VO2max , peak power output (Wmax) and power output at 2 mmol/L [la(-)] by 4.6 ± 3.7%, 2.1 ± 2.8%, and 10 ± 12%, respectively (P training compared with TRAD training (ES = 1.34, ES = 0.85, and ES = 0.71, respectively). The present study suggests that block periodization of training provides superior adaptations to traditional organization during a 4-week endurance training period, despite similar training volume and intensity. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. New Potentiometric Wireless Chloride Sensors Provide High Resolution Information on Chemical Transport Processes in Streams

    Directory of Open Access Journals (Sweden)

    Keith Smettem

    2017-07-01

    Full Text Available Quantifying the travel times, pathways, and dispersion of solutes moving through stream environments is critical for understanding the biogeochemical cycling processes that control ecosystem functioning. Validation of stream solute transport and exchange process models requires data obtained from in-stream measurement of chemical concentration changes through time. This can be expensive and time consuming, leading to a need for cheap distributed sensor arrays that respond instantly and record chemical transport at points of interest on timescales of seconds. To meet this need we apply new, low-cost (in the order of a euro per sensor potentiometric chloride sensors used in a distributed array to obtain data with high spatial and temporal resolution. The application here is to monitoring in-stream hydrodynamic transport and dispersive mixing of an injected chemical, in this case NaCl. We present data obtained from the distributed sensor array under baseflow conditions for stream reaches in Luxembourg and Western Australia. The reaches were selected to provide a range of increasingly complex in-channel flow patterns. Mid-channel sensor results are comparable to data obtained from more expensive electrical conductivity meters, but simultaneous acquisition of tracer data at several positions across the channel allows far greater spatial resolution of hydrodynamic mixing processes and identification of chemical ‘dead zones’ in the study reaches.

  13. Fine-Motion-Control Method for Realizing High-Accuracy and High-Speed Contact Motion of Industrial Robots by Employing Sensorless Force Control

    Science.gov (United States)

    Shimada, Naoki; Yoshioka, Takashi; Ohishi, Kiyoshi; Miyazaki, Toshimasa

    This paper proposes a new fine-motion-control method for realizing high-accuracy and high-speed contact motion of industrial robots by employing sensorless force control. Today, although industrial robots have become considerably important in the modern industrial society, their functions are limited. A typical limited function is the positioning motion control of robots used in the manufacturing industry. Contact motion is necessary for almost all new applications. In this study, by employing the proposed motion control, smooth and quick contact motion of industrial robots is realized by using a sensorless I-P (Integral-Proportional) force feedback controller. The proposed method is simple and effective, takes into account both the inertia of a robot and the behavior of the I-P force controller. In the experiments, a three-degree-of-freedom robot is brought into contact with an object (a concrete block or a rubber board) by the I-P force control using the proposed method. Further, in the experiment, the motion of the robot's end-effector was considered. The validity of the proposed method is confirmed by using a six-axis force sensor and an acceleration sensor in the contact motion experiments.

  14. CARETS: A prototype regional environmental information system. Volume 6: Cost, accuracy and consistency comparisons of land use maps made from high-altitude aircraft photography and ERTS imagery

    Science.gov (United States)

    Alexander, R. H. (Principal Investigator); Fitzpatrick, K. A.

    1975-01-01

    The author has identified the following significant results. Level 2 land use maps produced at three scales (1:24,000, 1:100,000, and 1:250,000) from high altitude photography were compared with each other and with point data obtained in the field. The same procedures were employed to determine the accuracy of the Level 1 land use maps produced at 1:250,000 from high altitude photography and color composite ERTS imagery. Accuracy of the Level 2 maps was 84.9 percent at 1:24,000, 77.4 percent at 1:100,000 and 73.0 percent at 1:250,000. Accuracy of the Level 1 1:250,000 maps was 76.5 percent for aerial photographs and 69.5 percent for ERTS imagery. The cost of Level 2 land use mapping at 1:24,000 was found to be high ($11.93 per sq km). The cost of mapping at 1:100,000 ($1.75) was about two times as expensive as mapping at 1:250,000 ($.88), and the accuracy increased by only 4.4 percent.

  15. Canopy Temperature and Vegetation Indices from High-Throughput Phenotyping Improve Accuracy of Pedigree and Genomic Selection for Grain Yield in Wheat.

    Science.gov (United States)

    Rutkoski, Jessica; Poland, Jesse; Mondal, Suchismita; Autrique, Enrique; Pérez, Lorena González; Crossa, José; Reynolds, Matthew; Singh, Ravi

    2016-09-08

    Genomic selection can be applied prior to phenotyping, enabling shorter breeding cycles and greater rates of genetic gain relative to phenotypic selection. Traits measured using high-throughput phenotyping based on proximal or remote sensing could be useful for improving pedigree and genomic prediction model accuracies for traits not yet possible to phenotype directly. We tested if using aerial measurements of canopy temperature, and green and red normalized difference vegetation index as secondary traits in pedigree and genomic best linear unbiased prediction models could increase accuracy for grain yield in wheat, Triticum aestivum L., using 557 lines in five environments. Secondary traits on training and test sets, and grain yield on the training set were modeled as multivariate, and compared to univariate models with grain yield on the training set only. Cross validation accuracies were estimated within and across-environment, with and without replication, and with and without correcting for days to heading. We observed that, within environment, with unreplicated secondary trait data, and without correcting for days to heading, secondary traits increased accuracies for grain yield by 56% in pedigree, and 70% in genomic prediction models, on average. Secondary traits increased accuracy slightly more when replicated, and considerably less when models corrected for days to heading. In across-environment prediction, trends were similar but less consistent. These results show that secondary traits measured in high-throughput could be used in pedigree and genomic prediction to improve accuracy. This approach could improve selection in wheat during early stages if validated in early-generation breeding plots. Copyright © 2016 Rutkoski et al.

  16. Canopy Temperature and Vegetation Indices from High-Throughput Phenotyping Improve Accuracy of Pedigree and Genomic Selection for Grain Yield in Wheat

    Directory of Open Access Journals (Sweden)

    Jessica Rutkoski

    2016-09-01

    Full Text Available Genomic selection can be applied prior to phenotyping, enabling shorter breeding cycles and greater rates of genetic gain relative to phenotypic selection. Traits measured using high-throughput phenotyping based on proximal or remote sensing could be useful for improving pedigree and genomic prediction model accuracies for traits not yet possible to phenotype directly. We tested if using aerial measurements of canopy temperature, and green and red normalized difference vegetation index as secondary traits in pedigree and genomic best linear unbiased prediction models could increase accuracy for grain yield in wheat, Triticum aestivum L., using 557 lines in five environments. Secondary traits on training and test sets, and grain yield on the training set were modeled as multivariate, and compared to univariate models with grain yield on the training set only. Cross validation accuracies were estimated within and across-environment, with and without replication, and with and without correcting for days to heading. We observed that, within environment, with unreplicated secondary trait data, and without correcting for days to heading, secondary traits increased accuracies for grain yield by 56% in pedigree, and 70% in genomic prediction models, on average. Secondary traits increased accuracy slightly more when replicated, and considerably less when models corrected for days to heading. In across-environment prediction, trends were similar but less consistent. These results show that secondary traits measured in high-throughput could be used in pedigree and genomic prediction to improve accuracy. This approach could improve selection in wheat during early stages if validated in early-generation breeding plots.

  17. Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Pei; Wang, Ximing; Cheng, Zhaoping; Ji, Xiaopeng; Duan, Yanhua [Shandong University, Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Chen, Jiuhong [CT Research Collaboration, Siemens Ltd. China, Beijing (China)

    2012-10-15

    To compare accuracy, image quality and radiation dose between high-pitch spiral and sequential modes on 128-slice dual-source computed tomographic (DSCT) angiography in children with congenital heart disease (CHD). Forty patients suspected with CHD underwent 128-slice DSCT angiography with high-pitch mode and sequential mode respectively. All the anomalies were confirmed by the surgical and/or the conventional cardiac angiography (CCA) findings. The diagnostic accuracy, the subjective and objective image quality and effective radiation doses were compared. There was no significant difference in diagnostic accuracy ({chi}{sup 2} = 0.963, P > 0.05), the objective parameters for image quality (P > 0.05) and the image quality of great vessels (u = 167.500, P > 0.05) between the two groups. The image quality of intracardiac structures and coronary arteries was significantly better in the sequential mode group than that in the high-pitch group (u = 112.500 and 100.000, P < 0.05). The mean effective dose in high-pitch group (0.17 {+-} 0.05 mSv) was significantly lower (t = 5.287, P < 0.05) than that in the sequential mode group (0.29 {+-} 0.09 mSv). Both the high-pitch and the sequential modes for 128-slice DSCT angiography provide high accuracy for the assessment of CHD in children, while the high-pitch mode, even with some image quality decrease, further significantly lowers the radiation dose. (orig.)

  18. Predictors of early acceptance of free spectacles provided to junior high school students in China.

    Science.gov (United States)

    Keay, Lisa; Zeng, Yangfa; Munoz, Beatriz; He, Mingguang; Friedman, David S

    2010-10-01

    To examine factors influencing adherence to spectacle wear and perceived value within a prospective 1-month trial of ready-made and custom spectacles in school-aged children with uncorrected refractive error in urban China. A total of 428 students aged 12 to 15 years with at least 1 diopter of uncorrected refractive error were given free spectacles and evaluated 1 month later at an unannounced visit. Demographic factors, vision, optical effects, and perceptions were modeled as predictors of observed use and perceived value using logistic regression adjusted for spectacle allocation. Of 415 students, 388 (93.5%) planned to use their spectacles, 227 (54.7%) valued their spectacles highly, 204 (49.2%) had their spectacles on hand, and 13 (3.0%) were lost to follow-up. Female students were 1.72 times (95% confidence interval [CI], 1.10-2.68), students from lower income households were 1.78 times (1.32-2.39), and those not concerned over appearance were 2.04 times (1.25-3.36) more likely to have spectacles on hand. Students with a pupil size of 4 mm or greater were 2.55 times (95% CI, 1.61-4.03) and students with spectacle vision worse than 20/20 were 2.06 times (1.20-3.49) more likely to have spectacles on hand. Self-report of high perceived value was 2.23 times (95% CI, 1.30-3.80) more likely with 20/20 spectacle vision, 1.63 times (1.06-2.52) more likely with base-in prismatic effects of 0.5 prism diopters or more, 3.52 times (2.03-6.13) more likely when students would not tolerate blur to avoid wearing spectacles, and 2.16 times (1.24-3.76) more likely with disbelief that spectacles would make vision worse. Spectacle type had no effect. Although most students planned to use their spectacles, only half were observed using them. Day-to-day use might increase if students were less concerned over appearance. Optical factors and beliefs surrounding spectacles are also predictive of acceptance. These findings provide further understanding of spectacle acceptance in

  19. High angular accuracy manufacture method of micro v-grooves based on tool alignment by on-machine measurement.

    Science.gov (United States)

    Zhang, Xiaodong; Jiang, Lili; Zeng, Zhen; Fang, Fengzhou; Liu, Xianlei

    2015-10-19

    Micro v-groove has found wide applications in optical areas as one of the most important structures. However, its performance is significantly affected by its angular geometry accuracy. The diamond cutting has been commonly used as the fabrication method of micro v-groove, but it is still difficult to guarantee the cutting tool angle, which is limited by the measurement accuracy in the manufacture and mounting of the diamond tool. A cutting tool alignment method based on the on-machine measurement is proposed to improve the fabricated quality of the v-groove angle. An on-machine probe is employed to scan the v-groove geometrical deviation precisely. The system errors model, data processing algorithm and tool alignment methods are analyzed in details. Experimental results show that the measurement standard deviation within 0.01° can be achieved. Retro-reflection mirrors are fabricated and measured finally by the proposed method for verification.

  20. Evaluation of Argos Telemetry Accuracy in the High-Arctic and Implications for the Estimation of Home-Range Size.

    Directory of Open Access Journals (Sweden)

    Sylvain Christin

    Full Text Available Animal tracking through Argos satellite telemetry has enormous potential to test hypotheses in animal behavior, evolutionary ecology, or conservation biology. Yet the applicability of this technique cannot be fully assessed because no clear picture exists as to the conditions influencing the accuracy of Argos locations. Latitude, type of environment, and transmitter movement are among the main candidate factors affecting accuracy. A posteriori data filtering can remove "bad" locations, but again testing is still needed to refine filters. First, we evaluate experimentally the accuracy of Argos locations in a polar terrestrial environment (Nunavut, Canada, with both static and mobile transmitters transported by humans and coupled to GPS transmitters. We report static errors among the lowest published. However, the 68th error percentiles of mobile transmitters were 1.7 to 3.8 times greater than those of static transmitters. Second, we test how different filtering methods influence the quality of Argos location datasets. Accuracy of location datasets was best improved when filtering in locations of the best classes (LC3 and 2, while the Douglas Argos filter and a homemade speed filter yielded similar performance while retaining more locations. All filters effectively reduced the 68th error percentiles. Finally, we assess how location error impacted, at six spatial scales, two common estimators of home-range size (a proxy of animal space use behavior synthetizing movements, the minimum convex polygon and the fixed kernel estimator. Location error led to a sometimes dramatic overestimation of home-range size, especially at very local scales. We conclude that Argos telemetry is appropriate to study medium-size terrestrial animals in polar environments, but recommend that location errors are always measured and evaluated against research hypotheses, and that data are always filtered before analysis. How movement speed of transmitters affects location

  1. Geometric Accuracy Investigations of SEVIRI High Resolution Visible (HRV Level 1.5 Imagery

    Directory of Open Access Journals (Sweden)

    Sultan Kocaman Aksakal

    2013-05-01

    Full Text Available GCOS (Global Climate Observing System is a long-term program for monitoring the climate, detecting the changes, and assessing their impacts. Remote sensing techniques are being increasingly used for climate-related measurements. Imagery of the SEVIRI instrument on board of the European geostationary satellites Meteosat-8 and Meteosat-9 are often used for the estimation of essential climate variables. In a joint project between the Swiss GCOS Office and ETH Zurich, geometric accuracy and temporal stability of 1-km resolution HRV channel imagery of SEVIRI have been evaluated over Switzerland. A set of tools and algorithms has been developed for the investigations. Statistical analysis and blunder detection have been integrated in the process for robust evaluation. The relative accuracy is evaluated by tracking large numbers of feature points in consecutive HRV images taken at 15-minute intervals. For the absolute accuracy evaluation, lakes in Switzerland and surroundings are used as reference. 20 lakes digitized from Landsat orthophotos are transformed into HRV images and matched via 2D translation terms at sub-pixel level. The algorithms are tested using HRV images taken on 24 days in 2008 (2 days per month. The results show that 2D shifts that are up to 8 pixels are present both in relative and absolute terms.

  2. The high accuracy model of the 19 July 2012 solar flare: kinetic description, calculations of X-Ray and microwave emission

    Science.gov (United States)

    Gritsyk, Pavel; Somov, Boris

    2016-04-01

    The limb white-light solar flare M7.7 class was observed at the 19 July 2012 at 05:58UT by RHESSI, GOES and SDO with high spectral, spatial and temporal resolution. These new data make possible to test modern models of solar flares. The flare, which considered here, locates in the picture plane, so we well see two different hard X-ray sources: footpoint and above-the-loop-top. The loop was observed in whit-light and microwave wavelengths. The key part of the presented work is high accuracy kinetic model, which describe behavior of electrons in the target - solar flare loop. We interpret the footpoint source in approximation of the thick target model with reverse current and above-the-loop-top source - in the thin target approximation. The microwave spectrum in the range from 1 to 50 GHz was calculated. Our results fit well the observational data, particularly so important parameter as hard X-Ray spectral index. But intensity of emission of the coronal source was estimated incorrect, it was low than observed. This problem can be solved by taking into account effects of particles acceleration in the collapsing magnetic trap, when fast electrons receive additional energy without changing the index of their energy spectrum. In the result we have flux ~ 5 1010 erg cm-2 s-1 for electrons with energies more then 15 keV, that ~ 5 times larger then in the case classical thick target model. Accordingly , so high flux of electrons to the Chromosphere provides effective heating of the cold plasma in the target, but the reverse current electric field restrict depth of the electron penetration. Received in this work estimates may be used for interpretation of the solar flare optical source formation and evolution.

  3. Very high precision and accuracy analysis of triple isotopic ratios of water. A critical instrumentation comparison study.

    Science.gov (United States)

    Gkinis, Vasileios; Holme, Christian; Morris, Valerie; Thayer, Abigail Grace; Vaughn, Bruce; Kjaer, Helle Astrid; Vallelonga, Paul; Simonsen, Marius; Jensen, Camilla Marie; Svensson, Anders; Maffrezzoli, Niccolo; Vinther, Bo; Dallmayr, Remi

    2017-04-01

    We present a performance comparison study between two state of the art Cavity Ring Down Spectrometers (Picarro L2310-i, L2140-i). The comparison took place during the Continuous Flow Analysis (CFA) campaign for the measurement of the Renland ice core, over a period of three months. Instant and complete vaporisation of the ice core melt stream, as well as of in-house water reference materials is achieved by accurate control of microflows of liquid into a homemade calibration system by following simple principles of the Hagen-Poiseuille law. Both instruments share the same vaporisation unit in a configuration that minimises sample preparation discrepancies between the two analyses. We describe our SMOW-SLAP calibration and measurement protocols for such a CFA application and present quality control metrics acquired during the full period of the campaign on a daily basis. The results indicate an unprecedented performance for all 3 isotopic ratios (δ2H, δ17O, δ18O ) in terms of precision, accuracy and resolution. We also comment on the precision and accuracy of the second order excess parameters of HD16O and H217O over H218O (Dxs, Δ17O ). To our knowledge these are the first reported CFA measurements at this level of precision and accuracy for all three isotopic ratios. Differences on the performance of the two instruments are carefully assessed during the measurement and reported here. Our quality control protocols extend to the area of low water mixing ratios, a regime in which often atmospheric vapour measurements take place and Cavity Ring Down Analysers show a poorer performance due to the lower signal to noise ratios. We address such issues and propose calibration protocols from which water vapour isotopic analyses can benefit from.

  4. Training Physicians to Provide High-Value, Cost-Conscious Care A Systematic Review

    NARCIS (Netherlands)

    Stammen, L.A.; Stalmeijer, R.E.; Paternotte, E.; Pool, A.O.; Driessen, E.W.; Scheele, F.; Stassen, L.P.S.

    2015-01-01

    Importance Increasing health care expenditures are taxing the sustainability of the health care system. Physicians should be prepared to deliver high-value, cost-conscious care. Objective To understand the circumstances in which the delivery of high-value, cost-conscious care is learned, with a goal

  5. Practicing provider-initiated HIV testing in high prevalence settings: consent concerns and missed preventive opportunities

    OpenAIRE

    Shayo Elizabeth H; Blystad Astrid; Njeru Mercy K; Nyamongo Isaac K; Fylkesnes Knut

    2011-01-01

    Abstract Background Counselling is considered a prerequisite for the proper handling of testing and for ensuring effective HIV preventive efforts. HIV testing services have recently been scaled up substantially with a particular focus on provider-initiated models. Increasing HIV test rates have been attributed to the rapid scale-up of the provider-initiated testing model, but there is limited documentation of experiences with this new service model. The aim of this study was to determine the ...

  6. Probe-level linear model fitting and mixture modeling results in high accuracy detection of differential gene expression

    Directory of Open Access Journals (Sweden)

    Lemieux Sébastien

    2006-08-01

    Full Text Available Abstract Background The identification of differentially expressed genes (DEGs from Affymetrix GeneChips arrays is currently done by first computing expression levels from the low-level probe intensities, then deriving significance by comparing these expression levels between conditions. The proposed PL-LM (Probe-Level Linear Model method implements a linear model applied on the probe-level data to directly estimate the treatment effect. A finite mixture of Gaussian components is then used to identify DEGs using the coefficients estimated by the linear model. This approach can readily be applied to experimental design with or without replication. Results On a wholly defined dataset, the PL-LM method was able to identify 75% of the differentially expressed genes within 10% of false positives. This accuracy was achieved both using the three replicates per conditions available in the dataset and using only one replicate per condition. Conclusion The method achieves, on this dataset, a higher accuracy than the best set of tools identified by the authors of the dataset, and does so using only one replicate per condition.

  7. High-accuracy fiber optical microphone in a DBR fiber laser based on a nanothick silver diaphragm by self-mixing technique.

    Science.gov (United States)

    Du, Zhengting; Lu, Liang; Zhang, Wenhua; Yang, Bo; Wu, Shuang; Zhao, Yunhe; Xu, Feng; Wang, Zhiping; Gui, Huaqiao; Liu, Jianguo; Yu, Benli

    2013-12-16

    A high-accuracy fiber optical microphone (FOM) is first applied by self-mixing technique in a DBR fiber laser based on a nanothick silver diaphragm. The nanothick silver diaphragm fabricated by the convenient and low cost electroless plating method is functioned as sensing diaphragm due to critically susceptible to the air vibration. Simultaneously, micro-vibration theory model of self-mixing interference fiber optical microphone is deduced based on quasi-analytical method. The dynamic property to frequencies and amplitudes are experimentally carried out to characterize the fabricated FOM and also the reproduced sound of news and music can clearly meet the ear of the people which shows the technique proposed in this paper guarantee steady, high signal-noise ratio operation and outstanding accuracy in the DBR fiber laser which is potential to medical and security applications such as real-time voice reproduction for throat and voiceprint verification.

  8. ELABORATION OF HIGH-VOLTAGE PULSE INSTALLATIONS AND PROVIDING THEIR OPERATION PROTECTIVE MEASURES

    Directory of Open Access Journals (Sweden)

    А. М. Hashimov

    2016-01-01

    Full Text Available The article presents design engineering methods for the high-voltage pulse installations of technological purpose for disinfection of drinking water, sewage, and edible liquids by high field micro- and nanosecond pulsing exposure. Designing potentialities are considered of the principal elements of the high-voltage part and the discharge circuit of the installations towards assuring the best efficient on-load utilization of the source energy and safe operation of the high-voltage equipment. The study shows that for disinfection of drinking water and sewage it is expedient to apply microsecond pulse actions causing the electrohydraulic effect in aqueous media with associated complex of physical processes (ultraviolet emission, generation of ozone and atomic oxygen, mechanical compression waves, etc. having detrimental effect on life activity of the microorganisms. In case of disinfecting edible liquids it is recommended to use the nanosecond pulses capable of straight permeating the biological cell nucleus, inactivating it. Meanwhile, the nutritive and biological values of the foodstuffs are saved and their organoleptic properties are improved. It is noted that in elaboration process of high-frequency pulse installations special consideration should be given to issues of the operating personnel safety discipline and securing conditions for the entire installation uninterrupted performance. With this objective in view the necessary requirements should be fulfilled on shielding the high- and low-voltage installation parts against high-frequency electromagnetic emissions registered by special differential sensors. Simultaneously, the abatement measures should be applied on the high-voltage equipment operational noise level. The authors offer a technique for noise abatement to admissible levels (lower than 80 dB A by means of coating the inside surface with shielded enclosure of densely-packed abutting sheets of porous electro-acoustic insulating

  9. Access to high-volume surgeons and the opportunity cost of performing radical prostatectomy by low-volume providers.

    Science.gov (United States)

    Barzi, Afsaneh; Klein, Eric A; Daneshmand, Siamak; Gill, Inderbir; Quinn, David I; Sadeghi, Sarmad

    2017-07-01

    Evidence suggests that redirecting surgeries to high-volume providers may be associated with better outcomes and significant societal savings. Whether such referrals are feasible remains unanswered. Medicare Provider Utilization and Payment Data, SEER 18, and US Incidence data were used to determine the geographic distribution and radical prostatectomy volume for providers. Access was defined as availability of a high-volume provider within driving distance of 100 miles. The opportunity cost was defined as the value of benefits achievable by performing the surgery by a high-volume provider that was forgone by not making a referral. The savings per referral were derived from a published Markov model for radical prostatectomy. A total of 14% of providers performed>27% of the radical prostatectomies with>30 cases per year and were designated high-volume providers. Providers with below-median volume (≤16 prostatectomies per year) performed>32% of radical prostatectomies. At least 47% of these were within a 100-mile driving distance (median = 22 miles), and therefore had access to a high-volume provider (>30 prostatectomies per year). This translated into a discounted savings of more than $24 million per year, representing the opportunity cost of not making a referral. The average volume for high- and low-volume providers was 55 and 13, respectively, resulting in an annual experience gap of 43 and a cumulative gap of 125 surgeries over 3 years. In 2014, the number of surgeons performing radical prostatectomy decreased by 5% while the number of high- and low-volume providers decreased by 25% and 11% showing a faster decline in the number of high-volume providers compared with low-volume surgeons. About half of prostatectomies performed by surgeons with below-median annual volume were within a 100-mile driving distance (median of 22 miles) of a high-volume surgeon. Such a referral may result in minimal additional costs and substantially improved outcomes. Copyright

  10. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dijken, Bart R.J. van [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); Laar, Peter Jan van; Hoorn, Anouk van der [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Holtman, Gea A. [University of Groningen, University Medical Center Groningen, Department of General Practice, Groningen (Netherlands)

    2017-10-15

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. (orig.)

  11. Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

    Science.gov (United States)

    Verkouteren, R Michael; Verkouteren, Jennifer R

    2009-10-15

    We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 microg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.

  12. High-accuracy absolute rotation rate measurements with a large ring laser gyro: establishing the scale factor.

    Science.gov (United States)

    Hurst, Robert B; Mayerbacher, Marinus; Gebauer, Andre; Schreiber, K Ulrich; Wells, Jon-Paul R

    2017-02-01

    Large ring lasers have exceeded the performance of navigational gyroscopes by several orders of magnitude and have become useful tools for geodesy. In order to apply them to tests in fundamental physics, remaining systematic errors have to be significantly reduced. We derive a modified expression for the Sagnac frequency of a square ring laser gyro under Earth rotation. The modifications include corrections for dispersion (of both the gain medium and the mirrors), for the Goos-Hänchen effect in the mirrors, and for refractive index of the gas filling the cavity. The corrections were measured and calculated for the 16  m2 Grossring laser located at the Geodetic Observatory Wettzell. The optical frequency and the free spectral range of this laser were measured, allowing unique determination of the longitudinal mode number, and measurement of the dispersion. Ultimately we find that the absolute scale factor of the gyroscope can be estimated to an accuracy of approximately 1 part in 108.

  13. Presenting a high accuracy Theta-Phi-style fiber-positioner prototype with a 15-mm pitch

    Science.gov (United States)

    Haeuser, Marco; Lang-Bardl, Florian; Richter, Josef; Hess, Hans-Joachim; Degwert, Adrian; Karasz, Adolf; Kosyra, Ralf; Hopp, Ulrich; Bender, Ralf

    2014-07-01

    We present a Θ - Φ-style fiber-positioner prototype, which will be controlled via the EMI-robust CAN-Bus. Our positioner points without iterations or a metrology system. Due to the overlapping patrol disc of 17.3 mm diameter, we reach a filling factor of 100 %. The positioners diameter is 14.6 mm, containing the control electronics on a contemporary PCB of 13.5 mm width. While moving, the power consumption does not lead to a significant rise in temperature. Given a mechanical reference point measured by stall detection, the absolute accuracy is 27 μm (1σ = 14 µm) and pointings are repeatable with 7 μm (1σ = 4 μm). Better positioning may be reachable with upcoming calibration.

  14. SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ellens, N [Johns Hopkins University, Baltimore, Maryland (United States); Farahani, K [National Cancer Institute, Bethesda, MD (United States)

    2015-06-15

    Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many

  15. High-resolution phylogeny providing insights towards the epidemiology, zoonotic aspects and taxonomy of sapoviruses

    NARCIS (Netherlands)

    Barry, A.F.; Durães-Carvalho, R.; Oliveira-Filho, Edmilson F.; Alfieri, A.; Poel, Van der W.H.M.

    2017-01-01

    The evolution, epidemiology and zoonotic aspects of Sapoviruses (SaV) are still not well explored. In this study, we applied high-resolution phylogeny to investigate the epidemiological and zoonotic origins as well as taxonomic classification of animal and human SaV. Bayesian framework analyses

  16. New Policies Allow High School Child Development Programs to Provide CDA Licensure

    Science.gov (United States)

    Langlais, Amanda G.

    2012-01-01

    Recent changes made by the Council for Professional Recognition to the Child Development Associate (CDA) credentialing program create an opportunity to redesign high school child development programs. On April 1, 2011, the Council for Professional Recognition lifted the age restriction in the CDA credentialing requirements, now allowing students…

  17. Reader Accuracy and Confidence in Diagnosing Diffuse Lung Disease on High-Resolution Computed Tomography of the Lungs: Impact of Sampling Frequency

    Energy Technology Data Exchange (ETDEWEB)

    Sundaram, B.; Gross, B.H.; Oh, E.; Mueller, N.; Myles, J.D.; Kazerooni, E.A. (Dept. of Radiology, Michigan Institute for Clinical Health Research, Univ. of Michigan Health System, Ann Arbor, Michigan (United States))

    2008-10-15

    Background: The accuracy of the number of high-resolution computed tomography (HRCT) images necessary to diagnose diffuse lung disease (DLD) is not well established. Purpose: To evaluate the impact of HRCT sampling frequency on reader confidence and accuracy for diagnosing DLD. Material and Methods: HRCT images of 100 consecutive patients with proven DLD were reviewed. They were: 48 usual interstitial pneumonia, 22 sarcoidosis, six hypersensitivity pneumonitis, five each of desquamative interstitial pneumonitis, eosinophilic granulomatosis, and lymphangioleiomyomatosis, and nine others. Inspiratory images at 1-cm increments throughout the lungs and three specified levels formed complete and limited examinations. In random order, three experts (readers 1, 2, and 3) ranked their top three diagnoses and rated confidence for their top diagnosis, independently and blinded to clinical information. Results: Using the complete versus limited examinations for correct first-choice diagnosis, accuracy for reader 1 (R1) was 81% versus 80%, respectively, for reader 2 (R2) 70% versus 70%, and for reader 3 (R3) 64% versus 59%. Reader accuracy within their top three choices for complete versus limited examinations was: R1 91% versus 91% of cases, respectively, R2 84% versus 83%, and R3 79% versus 72% of cases. No statistically significant differences were found between the diagnosis methods (P=0.28 for first diagnosis and P=0.17 for top three choices). The confidence intervals for individual raters showed considerable overlap, and the point estimates are almost identical. The mean interreader agreement for complete versus limited HRCT for both top and top three diagnoses were the same (moderate and fair, respectively). The mean intrareader agreement between complete and limited HRCT for top and top three diagnoses were substantial and moderate, respectively. Conclusion: Overall reader accuracy and confidence in diagnosis did not significantly differ when fewer or more HRCT images

  18. Genome sequencing of the high oil crop sesame provides insight into oil biosynthesis.

    Science.gov (United States)

    Wang, Linhai; Yu, Sheng; Tong, Chaobo; Zhao, Yingzhong; Liu, Yan; Song, Chi; Zhang, Yanxin; Zhang, Xudong; Wang, Ying; Hua, Wei; Li, Donghua; Li, Dan; Li, Fang; Yu, Jingyin; Xu, Chunyan; Han, Xuelian; Huang, Shunmou; Tai, Shuaishuai; Wang, Junyi; Xu, Xun; Li, Yingrui; Liu, Shengyi; Varshney, Rajeev K; Wang, Jun; Zhang, Xiurong

    2014-02-27

    Sesame, Sesamum indicum L., is considered the queen of oilseeds for its high oil content and quality, and is grown widely in tropical and subtropical areas as an important source of oil and protein. However, the molecular biology of sesame is largely unexplored. Here, we report a high-quality genome sequence of sesame assembled de novo with a contig N50 of 52.2 kb and a scaffold N50 of 2.1 Mb, containing an estimated 27,148 genes. The results reveal novel, independent whole genome duplication and the absence of the Toll/interleukin-1 receptor domain in resistance genes. Candidate genes and oil biosynthetic pathways contributing to high oil content were discovered by comparative genomic and transcriptomic analyses. These revealed the expansion of type 1 lipid transfer genes by tandem duplication, the contraction of lipid degradation genes, and the differential expression of essential genes in the triacylglycerol biosynthesis pathway, particularly in the early stage of seed development. Resequencing data in 29 sesame accessions from 12 countries suggested that the high genetic diversity of lipid-related genes might be associated with the wide variation in oil content. Additionally, the results shed light on the pivotal stage of seed development, oil accumulation and potential key genes for sesamin production, an important pharmacological constituent of sesame. As an important species from the order Lamiales and a high oil crop, the sesame genome will facilitate future research on the evolution of eudicots, as well as the study of lipid biosynthesis and potential genetic improvement of sesame.

  19. High-Speed AFM Images of Thermal Motion Provide Stiffness Map of Interfacial Membrane Protein Moieties

    OpenAIRE

    Preiner, Johannes; Horner, Andreas; Karner, Andreas; Ollinger, Nicole; Siligan, Christine; Pohl, Peter; Hinterdorfer, Peter

    2014-01-01

    The flexibilities of extracellular loops determine ligand binding and activation of membrane receptors. Arising from fluctuations in inter- and intraproteinaceous interactions, flexibility manifests in thermal motion. Here we demonstrate that quantitative flexibility values can be extracted from directly imaging the thermal motion of membrane protein moieties using high-speed atomic force microscopy (HS-AFM). Stiffness maps of the main periplasmic loops of single reconstituted water channels ...

  20. Software project estimation the fundamentals for providing high quality information to decision makers

    CERN Document Server

    Abran, Alain

    2015-01-01

    Software projects are often late and over-budget and this leads to major problems for software customers. Clearly, there is a serious issue in estimating a realistic, software project budget. Furthermore, generic estimation models cannot be trusted to provide credible estimates for projects as complex as software projects. This book presents a number of examples using data collected over the years from various organizations building software. It also presents an overview of the non-for-profit organization, which collects data on software projects, the International Software Benchmarking Stan

  1. EMODNet Bathymetry - building and providing a high resolution digital bathymetry for European seas

    Science.gov (United States)

    Schaap, D.

    2016-12-01

    Access to marine data is a key issue for the EU Marine Strategy Framework Directive and the EU Marine Knowledge 2020 agenda and includes the European Marine Observation and Data Network (EMODnet) initiative. The EMODnet Bathymetry project develops and publishes Digital Terrain Models (DTM) for the European seas. These are produced from survey and aggregated data sets that are indexed with metadata by adopting from SeaDataNet the Common Data Index (CDI) data discovery and access service and the Sextant data products catalogue service. SeaDataNet is a network of major oceanographic data centres around the European seas that manage, operate and further develop a pan-European infrastructure for marine and ocean data management. SeaDataNet is also setting and governing marine data standards, and exploring and establishing interoperability solutions to connect to other e-infrastructures on the basis of standards such as ISO and OGC. The SeaDataNet portal provides users a number of interrelated meta directories, an extensive range of controlled vocabularies, and the various SeaDataNet standards and tools. SeaDataNet at present gives overview and access to more than 1.8 million data sets for physical oceanography, chemistry, geology, geophysics, bathymetry and biology from more than 100 connected data centres from 34 countries riparian to European seas. The latest EMODnet Bathymetry DTM has a resolution of 1/8 arcminute * 1/8 arcminute and covers all European sea regions. Use is made of available and gathered surveys and already more than 13.000 surveys have been indexed by 27 European data providers from 15 countries. Also use is made of composite DTMs as generated and maintained by several data providers for their areas of interest. Already 44 composite DTMs are included in the Sextant data products catalogue. For areas without coverage use is made of the latest global DTM of GEBCO who is partner in the EMODnet Bathymetry project. In return GEBCO integrates the EMODnet

  2. Neuraminidase activity provides a practical read-out for a high throughput influenza antiviral screening assay

    Directory of Open Access Journals (Sweden)

    Wu Meng

    2008-09-01

    Full Text Available Abstract Background The emergence of influenza strains that are resistant to commonly used antivirals has highlighted the need to develop new compounds that target viral gene products or host mechanisms that are essential for effective virus replication. Existing assays to identify potential antiviral compounds often use high throughput screening assays that target specific viral replication steps. To broaden the search for antivirals, cell-based replication assays can be performed, but these are often labor intensive and have limited throughput. Results We have adapted a traditional virus neutralization assay to develop a practical, cell-based, high throughput screening assay. This assay uses viral neuraminidase (NA as a read-out to quantify influenza replication, thereby offering an assay that is both rapid and sensitive. In addition to identification of inhibitors that target either viral or host factors, the assay allows simultaneous evaluation of drug toxicity. Antiviral activity was demonstrated for a number of known influenza inhibitors including amantadine that targets the M2 ion channel, zanamivir that targets NA, ribavirin that targets IMP dehydrogenase, and bis-indolyl maleimide that targets protein kinase A/C. Amantadine-resistant strains were identified by comparing IC50 with that of the wild-type virus. Conclusion Antivirals with specificity for a broad range of targets are easily identified in an accelerated viral inhibition assay that uses NA as a read-out of replication. This assay is suitable for high throughput screening to identify potential antivirals or can be used to identify drug-resistant influenza strains.

  3. High sensitivity troponin T provides useful prognostic information in non-acute chest pain.

    Science.gov (United States)

    George, J; Jack, D; Mackle, G; Callaghan, T S; Wei, L; Lang, C C; Dow, E; Struthers, A D

    2012-02-01

    To evaluate the prognostic value of high-sensitivity troponin T (hs-cTnT) in patients who present to General Practitioners (GPs) with non-acute chest pain. A total of 625 patients who were referred by their GPs to a regional Rapid Access Chest Pain Clinic in Tayside, Scotland were consented and recruited. Diamond-Forrester pretest probability of coronary artery disease (CAD) was used to select patients with intermediate and high-pretest probability. Hs-cTnT and B-type Natriuretic Peptide (BNP) were measured and final diagnosis recorded. Twelve-month follow-up for cardiac events and hospital admission data was collected. Sensitivity, specificity, positive predictive value and negative predictive value (NPV), for both prognosis and diagnosis, were produced using various pre-specified cut-off values for hs-cTnT and BNP. A total of 579 patients were included in the final analysis. Of these, 477 had intermediate/high-pretest probability of CAD. A total of 431 (90.4%) of patients had a hs-cTnT ≤14 ng/l. In this study, hs-cTnT of 14 ng/l was the best cut-off for ruling out if a patient would have an admission for cardiac chest pain in the following 12 months (specificity 90%, NPV 91.4%). It performed well as a predictor of a subsequent negative diagnosis of cardiac chest pain with a specificity of 92.4% and NPV of 83.5%. Hs-cTnT, at the same level currently used in clinical practice as a diagnostic cut-off for myocardial infarction and acute coronary syndromes, is also a clinically-meaningful indicator for further 12-month cardiac chest pain hospital admissions in patients with non-acute chest pain referred to chest pain clinics by GPs.

  4. Attitudes of high school students regarding intimate relationships and gender norms in New Providence, The Bahamas

    Directory of Open Access Journals (Sweden)

    Nicolls, Donna

    2014-10-01

    Full Text Available This paper reports the attitudes and actions on relationships with the opposite sex of 1,002 Grade 10 and Grade 12 students in New Providence. Girls were more likely than boys to use aggressive behaviours in teen relationships. Some of the behaviours noted in teen relationships informed expectations of marital relationships, such as restricted access to friends of the opposite sex. The students endorsed a number of sex-related stereotypes, such as a man being the head of the household. Both male and female students indicated that it was acceptable for men to control their wives. Participation in aggressive and controlling behaviours by teens points to the need to educate students about how to develop more respectful relationships.

  5. A Highly Flexible, Automated System Providing Reliable Sample Preparation in Element- and Structure-Specific Measurements.

    Science.gov (United States)

    Vorberg, Ellen; Fleischer, Heidi; Junginger, Steffen; Liu, Hui; Stoll, Norbert; Thurow, Kerstin

    2016-10-01

    Life science areas require specific sample pretreatment to increase the concentration of the analytes and/or to convert the analytes into an appropriate form for the detection and separation systems. Various workstations are commercially available, allowing for automated biological sample pretreatment. Nevertheless, due to the required temperature, pressure, and volume conditions in typical element and structure-specific measurements, automated platforms are not suitable for analytical processes. Thus, the purpose of the presented investigation was the design, realization, and evaluation of an automated system ensuring high-precision sample preparation for a variety of analytical measurements. The developed system has to enable system adaption and high performance flexibility. Furthermore, the system has to be capable of dealing with the wide range of required vessels simultaneously, allowing for less cost and time-consuming process steps. However, the system's functionality has been confirmed in various validation sequences. Using element-specific measurements, the automated system was up to 25% more precise compared to the manual procedure and as precise as the manual procedure using structure-specific measurements. © 2015 Society for Laboratory Automation and Screening.

  6. Bio-Inspired Supramolecular Chemistry Provides Highly Concentrated Dispersions of Carbon Nanotubes in Polythiophene

    Directory of Open Access Journals (Sweden)

    Yen-Ting Lin

    2016-06-01

    Full Text Available In this paper we report the first observation, through X-ray diffraction, of noncovalent uracil–uracil (U–U dimeric π-stacking interactions in carbon nanotube (CNT–based supramolecular assemblies. The directionally oriented morphology determined using atomic force microscopy revealed highly organized behavior through π-stacking of U moieties in a U-functionalized CNT derivative (CNT–U. We developed a dispersion system to investigate the bio-inspired interactions between an adenine (A-terminated poly(3-adeninehexyl thiophene (PAT and CNT–U. These hybrid CNT–U/PAT materials interacted through π-stacking and multiple hydrogen bonding between the U moieties of CNT–U and the A moieties of PAT. Most importantly, the U···A multiple hydrogen bonding interactions between CNT–U and PAT enhanced the dispersion of CNT–U in a high-polarity solvent (DMSO. The morphology of these hybrids, determined using transmission electron microscopy, featured grape-like PAT bundles wrapped around the CNT–U surface; this tight connection was responsible for the enhanced dispersion of CNT–U in DMSO.

  7. Diagnostic Accuracy of Quantitative PCR (Xpert MTB/RIF) for Tuberculous Meningitis in a High Burden Setting: A Prospective Study

    Science.gov (United States)

    Patel, Vinod B.; Theron, Grant; Lenders, Laura; Matinyena, Brian; Connolly, Cathy; Singh, Ravesh; Coovadia, Yacoob; Ndung'u, Thumbi; Dheda, Keertan

    2013-01-01

    Background Tuberculous meningitis (TBM) is difficult to diagnose promptly. The utility of the Xpert MTB/RIF test for the diagnosis of TBM remains unclear, and the effect of host- and sample-related factors on test performance is unknown. This study sought to evaluate the sensitivity and specificity of Xpert MTB/RIF for the diagnosis of TBM. Methods and Findings 235 South-African patients with a meningeal-like illness were categorised as having definite (culture or Amplicor PCR positive), probable (anti-TBM treatment initiated but microbiological confirmation lacking), or non-TBM. Xpert MTB/RIF accuracy was evaluated using 1 ml of uncentrifuged and, when available, 3 ml of centrifuged cerebrospinal fluid (CSF). To evaluate the incremental value of MTB/RIF over a clinically based diagnosis, test accuracy was compared to a clinical score (CS) derived using basic clinical and laboratory information. Of 204 evaluable patients (of whom 87% were HIV-infected), 59 had definite TBM, 64 probable TBM, and 81 non-TBM. Overall sensitivity and specificity (95% CI) were 62% (48%–75%) and 95% (87%–99%), respectively. The sensitivity of Xpert MTB/RIF was significantly better than that of smear microscopy (62% versus 12%; p = 0.001) and significantly better than that of the CS (62% versus 30%; p = 0.001; C statistic 85% [79%–92%]). Xpert MTB/RIF sensitivity was higher when centrifuged versus uncentrifuged samples were used (82% [62%–94%] versus 47% [31%–61%]; p = 0.004). The combination of CS and Xpert MTB/RIF (Xpert MTB/RIF performed if CSMTB/RIF alone but with a ∼10% reduction in test usage. This overall pattern of results remained unchanged when the definite and probable TBM groups were combined. Xpert MTB/RIF was not useful in identifying TBM among HIV-uninfected individuals, although the sample was small. There was no evidence of PCR inhibition, and the limit of detection was ∼80 colony forming units per millilitre. Study limitations included a

  8. High accuracy navigation information estimation for inertial system using the multi-model EKF fusing adams explicit formula applied to underwater gliders.

    Science.gov (United States)

    Huang, Haoqian; Chen, Xiyuan; Zhang, Bo; Wang, Jian

    2017-01-01

    The underwater navigation system, mainly consisting of MEMS inertial sensors, is a key technology for the wide application of underwater gliders and plays an important role in achieving high accuracy navigation and positioning for a long time of period. However, the navigation errors will accumulate over time because of the inherent errors of inertial sensors, especially for MEMS grade IMU (Inertial Measurement Unit) generally used in gliders. The dead reckoning module is added to compensate the errors. In the complicated underwater environment, the performance of MEMS sensors is degraded sharply and the errors will become much larger. It is difficult to establish the accurate and fixed error model for the inertial sensor. Therefore, it is very hard to improve the accuracy of navigation information calculated by sensors. In order to solve the problem mentioned, the more suitable filter which integrates the multi-model method with an EKF approach can be designed according to different error models to give the optimal estimation for the state. The key parameters of error models can be used to determine the corresponding filter. The Adams explicit formula which has an advantage of high precision prediction is simultaneously fused into the above filter to achieve the much more improvement in attitudes estimation accuracy. The proposed algorithm has been proved through theory analyses and has been tested by both vehicle experiments and lake trials. Results show that the proposed method has better accuracy and effectiveness in terms of attitudes estimation compared with other methods mentioned in the paper for inertial navigation applied to underwater gliders. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  9. High-accuracy diagnostic tool for electron cloud observation in the LHC based on synchronous phase measurements

    CERN Document Server

    Esteban Müller, J F; Shaposhnikova, E; Valuch, D; Mastoridis, T

    2014-01-01

    Electron cloud effects such as heat load in the cryogenic system, pressure rise and beam instabilities are among the main limitations for the LHC operation with 25 ns spaced bunches. A new observation tool was developed to monitor the e-cloud activity and has been successfully used in the LHC during Run 1 (2010-2012). The power loss of each bunch due to the e-cloud can be estimated using very precise bunch-by-bunch measurement of the synchronous phase shift. In order to achieve the required accuracy, corrections for reflection in the cables and some systematic errors need to be applied followed by a post-processing of the measurements. Results clearly show the e-cloud build-up along the bunch trains and its evolution during each LHC fill as well as from fill to fill. Measurements during the 2012 LHC scrubbing run reveal a progressive reduction in the e-cloud activity and therefore a decrease in the secondary electron yield (SEY). The total beam power loss can be computed as a sum of the contributions from all...

  10. High-accuracy fourier transform interferometry, without oversampling, with a 1-bit analog-to-digital converter.

    Science.gov (United States)

    Daria, V R; Saloma, C

    2000-01-01

    We demonstrate a new technique for performing accurate Fourier transform interferometry with a 1-bit analog-to-digital (AD) converter that does not require oversampling of the interferogram, unlike in other 1-bit coding schemes that rely on delta-sigma modulation. Sampling aims at locating the intersections {z(i)} of the modulation term s(z) of the interferogram and a reference sinusoid r(z) = A cos(2pif(r)z), where z is the optical path difference. A new autocorrelation-based procedure that includes the accurate recovery of the equally sampled amplitude representation {s(k)} of s(z) from {z(i)} is utilized to calculate the square of the emission spectrum of the light source (sample). The procedure is suitable for interferograms that are corrupted with additive noise. Sinusoid-crossing sampling satisfies the Nyquist sampling criterion, and a z(i) exists within each sampling interval Delta = 1/2f(r), if A >or= |s(z)| for all z, and f(r) >or= f(c), where f(c) is the highest frequency component of s(z). By locating a crossing at an accuracy of 1 part in 2(16), we determine the multimode spectrum of an argon-ion laser with a 1-bit AD converter that performs like a 13-bit amplitude-sampling AD converter.

  11. Porter, PaleAle 4.0: high-accuracy prediction of protein secondary structure and relative solvent accessibility.

    Science.gov (United States)

    Mirabello, Claudio; Pollastri, Gianluca

    2013-08-15

    Protein secondary structure and solvent accessibility predictions are a fundamental intermediate step towards protein structure and function prediction. We present new systems for the ab initio prediction of protein secondary structure and solvent accessibility, Porter 4.0 and PaleAle 4.0. Porter 4.0 predicts secondary structure correctly for 82.2% of residues. PaleAle 4.0's accuracy is 80.0% for prediction in two classes with a 25% accessibility threshold. We show that the increasing training set sizes that come with the continuing growth of the Protein Data Bank keep yielding prediction quality improvements and examine the impact of protein resolution on prediction performances. Porter 4.0 and PaleAle 4.0 are freely available for academic users at http://distillf.ucd.ie/porterpaleale/. Up to 64 kb of input in FASTA format can be processed in a single submission, with predictions now being returned to the user within a single web page and, optionally, a single email.

  12. A review of atomic layer deposition providing high performance lithium sulfur batteries

    Science.gov (United States)

    Yan, Bo; Li, Xifei; Bai, Zhimin; Song, Xiaosheng; Xiong, Dongbin; Zhao, Mengli; Li, Dejun; Lu, Shigang

    2017-01-01

    With the significant obstacles that have been conquered in lithium-sulfur (Li-S) batteries, it is urgent to impel accelerating development of room-temperature Li-S batteries with high energy density and long-term stability. In view of the unique solid-liquid-solid conversion processes of Li-S batteries, however, designing effective strategies to address the insulativity and volume effect of cathode, shuttle of soluble polysulfides, and/or safety hazard of Li metal anode has been challenging. An atomic layer deposition (ALD) is a representative thin film technology with exceptional capabilities in developing atomic-precisely conformal films. It has been demonstrated to be a promise strategy of solving emerging issues in advanced electrical energy storage (EES) devices via the surface modification and/or the fabrication of complex nanostructured materials. In this review, the recent developments and significances on how ALD improves the performance of Li-S batteries were discussed in detail. Significant attention mainly focused on the various strategies with the use of ALD to refine the electrochemical interfaces and cell configurations. Furthermore, the novel opportunities and perspective associated with ALD for future research directions were summarized. This review may boost the development and application of advanced Li-S batteries using ALD.

  13. A Vesicle-to-Worm Transition Provides a New High-Temperature Oil Thickening Mechanism.

    Science.gov (United States)

    Derry, Matthew J; Mykhaylyk, Oleksandr O; Armes, Steven P

    2017-02-06

    Diblock copolymer vesicles are prepared via RAFT dispersion polymerization directly in mineral oil. Such vesicles undergo a vesicle-to-worm transition on heating to 150 °C, as judged by TEM and SAXS. Variable-temperature 1 H NMR spectroscopy indicates that this transition is the result of surface plasticization of the membrane-forming block by hot solvent, effectively increasing the volume fraction of the stabilizer block and so reducing the packing parameter for the copolymer chains. The rheological behavior of a 10 % w/w copolymer dispersion in mineral oil is strongly temperature-dependent: the storage modulus increases by five orders of magnitude on heating above the critical gelation temperature of 135 °C, as the non-interacting vesicles are converted into weakly interacting worms. SAXS studies indicate that, on average, three worms are formed per vesicle. Such vesicle-to-worm transitions offer an interesting new mechanism for the high-temperature thickening of oils. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The IceCube MasterClass: providing high school students an authentic research experience

    Science.gov (United States)

    Bravo Gallart, Silvia; Bechtol, Ellen; Schultz, David; Madsen, Megan; Demerit, Jean; IceCube Collaboration

    2017-01-01

    In May 2014, the first one-day long IceCube Masterclass for high school students was offered. The program was inspired by the masterclasses started in 2005 by the International Particle Physics Outreach Group and supported in the U.S. by QuarkNet. Participation in the IceCube masterclasses has grown each year, with a total of over 500 students in three U.S states and three European countries after three editions. In a masterclass, students join an IceCube research team to learn about astrophysics and replicate the results of a published paper, such as the discovery of astrophysical neutrinos or a measurement of the cosmic ray flux. We will discuss both the scientific and educational goals of the program as well as the organizational challenges. Data from the program evaluation will be used to support the need of educational activities based on actual research as a powerful approach for motivating more students to pursue STEM college programs, making science and scientists more approachable to teenagers, and helping students envision a career in science.

  15. High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Genovesi, Dario; Giorgetti, Assuero; Marzullo, Paolo [CNR, Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Bottai, Matteo [University of South Carolina, Division of Biostatistics, Columbia, SC (United States); Karolinska Institutet, Division of Biostatistics, Stockholm (Sweden); Di Martino, Fabio [AOUP, UO Fisica Sanitaria, Pisa (Italy)

    2012-01-15

    Appropriate use of SPECT imaging is regulated by evidence-based guidelines and appropriateness criteria in an effort to limit the burden of radiation administered to patients. We aimed at establishing whether the use of a low dose for stress-rest single-day nuclear myocardial perfusion imaging on an ultrafast (UF) cardiac gamma camera using cadmium-zinc-telluride solid-state detectors could be used routinely with the same accuracy obtained with standard doses and conventional cameras. To this purpose, 137 consecutive patients (mean age 61 {+-} 8 years) with known or suspected coronary artery disease (CAD) were enrolled. They underwent single-day low-dose stress-rest myocardial perfusion imaging using UF SPECT and invasive coronary angiography. Patients underwent the first scan with a 7-min acquisition time 10 min after the end of the stress protocol (dose range 185 to 222 MBq of {sup 99m}Tc-tetrofosmin). The rest scan (dose range 370 to 444 MBq of {sup 99m}Tc-tetrofosmin) was acquired with a 6-min acquisition time. The mean summed stress scores (SSS) and mean summed rest scores (SRS) were obtained semiquantitatively. Coronary angiograms showed significant epicardial CAD in 83% of patients. Mean SSS and SRS were 10 {+-} 5 and 3 {+-} 3, respectively. Overall the area under the ROC curve for the SSS values was 0.904, while the areas under the ROC curves for each vascular territory were 0.982 for the left anterior descending artery, 0.931 for the left circumflex artery and 0.889 for the right coronary artery. This pilot study demonstrated the feasibility of a low-dose single-day stress-rest fasting protocol performed using UF SPECT, with good sensitivity and specificity in detecting CAD at low patient exposure, opening new perspectives in the use of myocardial perfusion in ischaemic patients. (orig.)

  16. Effect of marital status on death rates. Part 1: High accuracy exploration of the Farr-Bertillon effect

    Science.gov (United States)

    Richmond, Peter; Roehner, Bertrand M.

    2016-05-01

    The Farr-Bertillon law says that for all age-groups the death rate of married people is lower than the death rate of people who are not married (i.e. single, widowed or divorced). Although this law has been known for over 150 years, it has never been established with well-controlled accuracy (e.g. error bars). This even let some authors argue that it was a statistical artifact. It is true that the data must be selected with great care, especially for age groups of small size (e.g. widowers under 25). The observations reported in this paper were selected in the way experiments are designed in physics, that is to say with the objective of minimizing error bars. Data appropriate for mid-age groups may be unsuitable for young age groups and vice versa. The investigation led to the following results. (1) The FB effect is very similar for men and women, except that (at least in western countries) its amplitude is 20% higher for men. (2) There is a marked difference between single/divorced persons on the one hand, for whom the effect is largest around the age of 40, and widowed persons on the other hand, for whom the effect is largest around the age of 25. (3) When different causes of death are distinguished, the effect is largest for suicide and smallest for cancer. For heart disease and cerebrovascular accidents, the fact of being married divides the death rate by 2.2 compared to non-married persons. (4) For young widowers the death rates are up to 10 times higher than for married persons of same age. This extreme form of the FB effect will be referred to as the ;young widower effect;. Chinese data are used to explore this effect more closely. A possible connection between the FB effect and Martin Raff's ;Stay alive; effect for the cells in an organism is discussed in the last section.

  17. Real-time continuous glucose monitoring shows high accuracy within 6 hours after sensor calibration: a prospective study.

    Directory of Open Access Journals (Sweden)

    Xiao-Yan Yue

    Full Text Available Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated with blood glucose measurements by blood gas/glucose analyzer every 12 hours. Venous blood was sampled every 2 to 4 hours, and glucose concentration was measured by standard central laboratory device (CLD and by blood gas/glucose analyzer. With CLD measurement as reference, relative absolute difference (mean±SD in CGMS and blood gas/glucose analyzer were 14.4%±12.2% and 6.5%±6.2%, respectively. The percentage of matched points in Clarke error grid zone A was 74.8% in CGMS, and 98.4% in blood gas/glucose analyzer. The relative absolute difference of CGMS obtained within 6 hours after sensor calibration (8.8%±7.2% was significantly less than that between 6 to 12 hours after calibration (20.1%±13.5%, p<0.0001. The percentage of matched points in Clarke error grid zone A was also significantly higher in data sets within 6 hours after calibration (92.4% versus 57.1%, p<0.0001. In conclusion, real-time subcutaneous CGMS is accurate in glucose monitoring in critically ill patients. CGMS sensor should be calibrated less than 6 hours, no matter what time interval recommended by manufacturer.

  18. The accuracy of {sup 68}Ga-PSMA PET/CT in primary lymph node staging in high-risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oebek, Can; Doganca, Tuenkut [Acibadem Taksim Hospital, Department of Urology, Istanbul (Turkey); Demirci, Emre [Sisli Etfal Training and Research Hospital, Department of Nuclear Medicine, Istanbul (Turkey); Ocak, Meltem [Istanbul University, Faculty of Pharmacy, Department of Pharmaceutical Technology, Istanbul (Turkey); Kural, Ali Riza [Acibadem University, Department of Urology, Istanbul (Turkey); Yildirim, Asif [Istanbul Medeniyet University, Department of Urology, Istanbul (Turkey); Yuecetas, Ugur [Istanbul Training and Research Hospital, Department of Urology, Istanbul (Turkey); Demirdag, Cetin [Istanbul University, Cerrahpasa School of Medicine, Department of Urology, Istanbul (Turkey); Erdogan, Sarper M. [Istanbul University, Cerrahpasa School of Medicine, Department of Public Health, Istanbul (Turkey); Kabasakal, Levent [Istanbul University, Cerrahpasa School of Medicine, Department of Nuclear Medicine, Istanbul (Turkey); Collaboration: Members of Urooncology Association, Turkey

    2017-10-15

    To assess the diagnostic accuracy of {sup 68}Ga-PSMA PET in predicting lymph node (LN) metastases in primary N staging in high-risk and very high-risk nonmetastatic prostate cancer in comparison with morphological imaging. This was a multicentre trial of the Society of Urologic Oncology in Turkey in conjunction with the Nuclear Medicine Department of Cerrahpasa School of Medicine, Istanbul University. Patients were accrued from eight centres. Patients with high-risk and very high-risk disease scheduled to undergo surgical treatment with extended LN dissection between July 2014 and October 2015 were included. Either MRI or CT was used for morphological imaging. PSMA PET/CT was performed and evaluated at a single centre. Sensitivity, specificity and accuracy were calculated for the detection of lymphatic metastases by PSMA PET/CT and morphological imaging. Kappa values were calculated to evaluate the correlation between the numbers of LN metastases detected by PSMA PET/CT and by histopathology. Data on 51 eligible patients are presented. The sensitivity, specificity and accuracy of PSMA PET in detecting LN metastases in the primary setting were 53%, 86% and 76%, and increased to 67%, 88% and 81% in the subgroup with of patients with ≥15 LN removed. Kappa values for the correlation between imaging and pathology were 0.41 for PSMA PET and 0.18 for morphological imaging. PSMA PET/CT is superior to morphological imaging for the detection of metastatic LNs in patients with primary prostate cancer. Surgical dissection remains the gold standard for precise lymphatic staging. (orig.)

  19. Effect of the high-pitch mode in dual-source computed tomography on the accuracy of three-dimensional volumetry of solid pulmonary nodules: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Ho; Oh, Yu Whan; Ham, Soo Youn [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Ki Yeol [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2015-06-15

    To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 +/- 0.9%, and 1.7 +/- 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 +/- 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 +/- 5.3%), with an IVV of 13.1 +/- 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule.

  20. Updating flood maps efficiently using existing hydraulic models, very-high-accuracy elevation data, and a geographic information system; a pilot study on the Nisqually River, Washington

    Science.gov (United States)

    Jones, Joseph L.; Haluska, Tana L.; Kresch, David L.

    2001-01-01

    A method of updating flood inundation maps at a fraction of the expense of using traditional methods was piloted in Washington State as part of the U.S. Geological Survey Urban Geologic and Hydrologic Hazards Initiative. Large savings in expense may be achieved by building upon previous Flood Insurance Studies and automating the process of flood delineation with a Geographic Information System (GIS); increases in accuracy and detail result from the use of very-high-accuracy elevation data and automated delineation; and the resulting digital data sets contain valuable ancillary information such as flood depth, as well as greatly facilitating map storage and utility. The method consists of creating stage-discharge relations from the archived output of the existing hydraulic model, using these relations to create updated flood stages for recalculated flood discharges, and using a GIS to automate the map generation process. Many of the effective flood maps were created in the late 1970?s and early 1980?s, and suffer from a number of well recognized deficiencies such as out-of-date or inaccurate estimates of discharges for selected recurrence intervals, changes in basin characteristics, and relatively low quality elevation data used for flood delineation. FEMA estimates that 45 percent of effective maps are over 10 years old (FEMA, 1997). Consequently, Congress has mandated the updating and periodic review of existing maps, which have cost the Nation almost 3 billion (1997) dollars. The need to update maps and the cost of doing so were the primary motivations for piloting a more cost-effective and efficient updating method. New technologies such as Geographic Information Systems and LIDAR (Light Detection and Ranging) elevation mapping are key to improving the efficiency of flood map updating, but they also improve the accuracy, detail, and usefulness of the resulting digital flood maps. GISs produce digital maps without manual estimation of inundated areas between

  1. Inter-comparison of two high-accuracy fast-response spectroscopic sensors of carbon dioxide: a case study

    Directory of Open Access Journals (Sweden)

    B. A. Flowers

    2012-05-01

    Full Text Available Tunable diode laser absorption (TDL and cavity ring-down spectroscopic (CRDS sensors for atmospheric carbon dioxide were co-deployed during summer and fall of 2010 in field and laboratory conditions at Los Alamos National Laboratory. Both sensors were characterized for accuracy and precision for ambient carbon dioxide measurements at ground level and compared using both laboratory and ambient field data. After post-processing that included water vapor correction and calibration to WMO reference standards, overall mean [12C16O2] = 392.05 ± 8.92 ppm and [12C16O2] = 392.22 ± 9.05 ppm were observed between 29 July and 16 August 2010. The mean difference between the CRDS and TDL data for 12CO2 was 0.04 ± 1.80 ppm (±1σ in 60 s for ambient field data, demonstrating the sensors meet the WMO/IAEA compatibility standard. The observations show over the 19-day period the [CO2]CRDS'/[CO2]TDL ratio exhibits a Gaussian distribution centered at x0 = 1.003 ± 3.38 × 10−5 (±1σ, indicating the ratio is dominated by random noise as opposed to a bias in the output of either sensor. The CRDS sensor is capable of measuring [12C16O2] to a precision of 23 ppb in 1 min and decreases to 6.5 ppb in 58 min. At one and 58-min, the TDL exhibits precisions of 29 ppb and 53 ppb. The CRDS is compact, fast, and stable; the TDL is larger and requires frequent calibrations to maintain its precision. The sensors also exhibit consistent hourly averaged diurnal values underscoring the interplay of biological, anthropogenic, and transport processes regulating CO2 at the site.

  2. Accuracy Assessment and Analysis for GPT2

    Directory of Open Access Journals (Sweden)

    YAO Yibin

    2015-07-01

    Full Text Available GPT(global pressure and temperature is a global empirical model usually used to provide temperature and pressure for the determination of tropospheric delay, there are some weakness to GPT, these have been improved with a new empirical model named GPT2, which not only improves the accuracy of temperature and pressure, but also provides specific humidity, water vapor pressure, mapping function coefficients and other tropospheric parameters, and no accuracy analysis of GPT2 has been made until now. In this paper high-precision meteorological data from ECWMF and NOAA were used to test and analyze the accuracy of temperature, pressure and water vapor pressure expressed by GPT2, testing results show that the mean Bias of temperature is -0.59℃, average RMS is 3.82℃; absolute value of average Bias of pressure and water vapor pressure are less than 1 mb, GPT2 pressure has average RMS of 7 mb, and water vapor pressure no more than 3 mb, accuracy is different in different latitudes, all of them have obvious seasonality. In conclusion, GPT2 model has high accuracy and stability on global scale.

  3. "Dilute-and-inject" multi-target screening assay for highly polar doping agents using hydrophilic interaction liquid chromatography high resolution/high accuracy mass spectrometry for sports drug testing.

    Science.gov (United States)

    Görgens, Christian; Guddat, Sven; Orlovius, Anne-Katrin; Sigmund, Gerd; Thomas, Andreas; Thevis, Mario; Schänzer, Wilhelm

    2015-07-01

    In the field of LC-MS, reversed phase liquid chromatography is the predominant method of choice for the separation of prohibited substances from various classes in sports drug testing. However, highly polar and charged compounds still represent a challenging task in liquid chromatography due to their difficult chromatographic behavior using reversed phase materials. A very promising approach for the separation of hydrophilic compounds is hydrophilic interaction liquid chromatography (HILIC). Despite its great potential and versatile advantages for the separation of highly polar compounds, HILIC is up to now not very common in doping analysis, although most manufacturers offer a variety of HILIC columns in their portfolio. In this study, a novel multi-target approach based on HILIC high resolution/high accuracy mass spectrometry is presented to screen for various polar stimulants, stimulant sulfo-conjugates, glycerol, AICAR, ethyl glucuronide, morphine-3-glucuronide, and myo-inositol trispyrophosphate after direct injection of diluted urine specimens. The usage of an effective online sample cleanup and a zwitterionic HILIC analytical column in combination with a new generation Hybrid Quadrupol-Orbitrap® mass spectrometer enabled the detection of highly polar analytes without any time-consuming hydrolysis or further purification steps, far below the required detection limits. The methodology was fully validated for qualitative and quantitative (AICAR, glycerol) purposes considering the parameters specificity; robustness (rRT  0.99); intra- and inter-day precision at low, medium, and high concentration levels (CV < 20%); limit of detection (stimulants and stimulant sulfo-conjugates < 10 ng/mL; norfenefrine; octopamine < 30 ng/mL; AICAR < 10 ng/mL; glycerol 100 μg/mL; ETG < 100 ng/mL); accuracy (AICAR 103.8-105.5%, glycerol 85.1-98.3% at three concentration levels) and ion suppression/enhancement effects.

  4. A high spatial resolution double-pulse Thomson scattering diagnostic; description, assessment of accuracy and examples of applications

    NARCIS (Netherlands)

    Beurskens, M. N. A.; Barth, C. J.; Cardozo, N. J. L.; van der Meiden, H. J.

    1999-01-01

    A high spatial resolution (3 mm full width half maximum, i.e. 2% of the minor radius) double-pulse multiposition Thomson scattering system was in operation at the Rijnhuizen tokamak project RTP from March 1996 until September 1998. It upgrades the previously installed single-pulse Thomson scattering

  5. Dose prediction accuracy of anisotropic analytical algorithm and pencil beam convolution algorithm beyond high density heterogeneity interface

    Directory of Open Access Journals (Sweden)

    Suresh B Rana

    2013-01-01

    Full Text Available Purpose: It is well known that photon beam radiation therapy requires dose calculation algorithms. The objective of this study was to measure and assess the ability of pencil beam convolution (PBC and anisotropic analytical algorithm (AAA to predict doses beyond high density heterogeneity. Materials and Methods: An inhomogeneous phantom of five layers was created in Eclipse planning system (version 8.6.15. Each layer of phantom was assigned in terms of water (first or top, air (second, water (third, bone (fourth, and water (fifth or bottom medium. Depth doses in water (bottom medium were calculated for 100 monitor units (MUs with 6 Megavoltage (MV photon beam for different field sizes using AAA and PBC with heterogeneity correction. Combinations of solid water, Poly Vinyl Chloride (PVC, and Styrofoam were then manufactured to mimic phantoms and doses for 100 MUs were acquired with cylindrical ionization chamber at selected depths beyond high density heterogeneity interface. The measured and calculated depth doses were then compared. Results: AAA′s values had better agreement with measurements at all measured depths. Dose overestimation by AAA (up to 5.3% and by PBC (up to 6.7% was found to be higher in proximity to the high-density heterogeneity interface, and the dose discrepancies were more pronounced for larger field sizes. The errors in dose estimation by AAA and PBC may be due to improper beam modeling of primary beam attenuation or lateral scatter contributions or combination of both in heterogeneous media that include low and high density materials. Conclusions: AAA is more accurate than PBC for dose calculations in treating deep-seated tumor beyond high-density heterogeneity interface.

  6. The Drift Diffusion Model can account for the accuracy and reaction time of value-based choices under high and low time pressure

    Directory of Open Access Journals (Sweden)

    Milica Milosavljevic

    2010-10-01

    Full Text Available An important open problem is how values are compared to make simple choices. A natural hypothesis is that the brain carries out the computations associated with the value comparisons in a manner consistent with the Drift Diffusion Model (DDM, since this model has been able to account for a large amount of data in other domains. We investigated the ability of four different versions of the DDM to explain the data in a real binary food choice task under conditions of high and low time pressure. We found that a seven-parameter version of the DDM can account for the choice and reaction time data with high-accuracy, in both the high and low time pressure conditions. The changes associated with the introduction of time pressure could be traced to changes in two key model parameters: the barrier height and the noise in the slope of the drift process.

  7. Relative accuracy of cervical and anal cytology for detection of high grade lesions by colposcope guided biopsy: a cut-point meta-analytic comparison.

    Directory of Open Access Journals (Sweden)

    Edward R Cachay

    Full Text Available BACKGROUND: We recently reported, using a receiver operating characteristic area metric, the first meta-analytic comparison of the relative accuracy of cervical and anal cytology in detecting moderate or severe histopathologic lesions by magnification directed punch biopsy. The aim of the present research was to meta-analytically examine cut-point specific operating characteristics (sensitivity, specificity of cervical and anal cytology in detecting high grade squamous intraepithelial lesion (HSIL histopathology by colposcope directed punch biopsy. METHODOLOGY/PRINCIPAL FINDINGS: The primary eligibility requirement was availability of tabulated cytology (normal, atypical cells of unclear significance [ASCUS], low grade squamous intraepithelial lesion, HSIL or atypical squamous cells cannot rule out high grade [ASC-H] and biopsy (accuracy was performed with examination of study quality criteria and heterogeneity. Thirty-three cervical and 11 anal publications were eligible between 1990 and 2010. Meta-analytically cut-point analysis showed that using a cut-point of ASCUS the sensitivity in both settings is similar while anal cytology is less specific than cervical cytology (specificity [95% confidence interval] 0.33 [0.20-0.49] vs. 0.53[0.40-0.66], p = 0.04 for the detection of HSIL histopathology by colposcope directed punch biopsy. CONCLUSIONS/SIGNIFICANCE: Using a cytology cut-point of HSIL or ASC-H, anal cytology is less sensitive but comparably specific to cervical cytology. However, using a cut-point of ASCUS, differences in accuracy were of borderline significance.

  8. Three-dimensional ultrasound demonstration of the fetal palate in high-risk patients: the accuracy of prenatal visualization.

    Science.gov (United States)

    Gindes, Liat; Weissmann-Brenner, Alina; Zajicek, Michal; Weisz, Boaz; Shrim, Alon; Tzadikevitch Geffen, Keren; Mendes, David; Kuint, Jaacov; Berkenstadt, Michal; Achiron, Reuven

    2013-05-01

    The aim of this research was to evaluate the ability of three-dimensional (3D) ultrasound for demonstrating the palate of fetuses at high risk for cleft palate. Fifty-seven fetuses at high risk for cleft palate were referred for specialist ultrasound at 12-40 weeks' gestation. A detailed assessment of palate was made using both two-dimensional and 3D ultrasounds on the axial plane. Antenatal diagnoses were compared with postnatal findings. Cleft palate was suspected in 13 (22.8%); a normal palate was demonstrated in 38 (67%), and in six (10.2%), the palate view could not be obtained. Mean gestational age at the first visit was 27 weeks 6 days (range of 12-40 weeks 3 days). Examination after delivery revealed that one of the 38 fetuses with presumed normal palate had a cleft hard palate, and one had a cleft soft palate (false negative 5%). Among the 13 fetuses with suspected cleft palate, three had an intact palate (false-positive 23%). Sensitivity, specificity, positive predictive value, and negative predictive value of detection of palatal clefts were 71.4%, 91.9%, 62.5%, and 94.4%, respectively. Using 3D technology, we diagnosed a cleft palate in 83% of high-risk cases, with 5% false negative. 3D technology might produce some technical artifacts resulting in a 23% false-positive rate. © 2013 John Wiley & Sons, Ltd.

  9. High-accuracy imputation for HLA class I and II genes based on high-resolution SNP data of population-specific references.

    Science.gov (United States)

    Khor, S-S; Yang, W; Kawashima, M; Kamitsuji, S; Zheng, X; Nishida, N; Sawai, H; Toyoda, H; Miyagawa, T; Honda, M; Kamatani, N; Tokunaga, K

    2015-12-01

    Statistical imputation of classical human leukocyte antigen (HLA) alleles is becoming an indispensable tool for fine-mappings of disease association signals from case-control genome-wide association studies. However, most currently available HLA imputation tools are based on European reference populations and are not suitable for direct application to non-European populations. Among the HLA imputation tools, The HIBAG R package is a flexible HLA imputation tool that is equipped with a wide range of population-based classifiers; moreover, HIBAG R enables individual researchers to build custom classifiers. Here, two data sets, each comprising data from healthy Japanese individuals of difference sample sizes, were used to build custom classifiers. HLA imputation accuracy in five HLA classes (HLA-A, HLA-B, HLA-DRB1, HLA-DQB1 and HLA-DPB1) increased from the 82.5-98.8% obtained with the original HIBAG references to 95.2-99.5% with our custom classifiers. A call threshold (CT) of 0.4 is recommended for our Japanese classifiers; in contrast, HIBAG references recommend a CT of 0.5. Finally, our classifiers could be used to identify the risk haplotypes for Japanese narcolepsy with cataplexy, HLA-DRB1*15:01 and HLA-DQB1*06:02, with 100% and 99.7% accuracy, respectively; therefore, these classifiers can be used to supplement the current lack of HLA genotyping data in widely available genome-wide association study data sets.

  10. Social Power Increases Interoceptive Accuracy

    NARCIS (Netherlands)

    Moeini-Jazani, Mehrad; Knoeferle, Klemens; de Moliere, Laura; Gatti, Elia; Warlop, Luk

    2017-01-01

    Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental

  11. ShapeGrabber FootScanner: a low cost high accuracy 3D system for the acquisition of human feet

    Science.gov (United States)

    Blais, Francois; Bisson, Joel A.; Williams, Steve; Robertson, Nancy; Rozin, Serge; Nelson, Andrew

    2000-03-01

    This paper presents a new acquisition method and the application of the technology for the acquisition of a person's foot. The sensor is designed to meet the requirements of measuring a variety of feet under various ambient optical conditions that can, in other circumstances, seriously affect the data measurements and reduce the reliability of the system. The most important distinction between this ranging method and other more classical approaches is the high tolerance of the method to external optical perturbations as well as reflections form other sensor heads. This allows its use in conventional 'store' or 'medical offices' that are usually bright places.

  12. Same-day diagnosis based on histology for women suspected of breast cancer: high diagnostic accuracy and favorable impact on the patient.

    Directory of Open Access Journals (Sweden)

    Maarten W Barentsz

    Full Text Available Same-day diagnosis based on histology is increasingly being offered to patients suspected of breast cancer. We evaluated to which extent same-day diagnosis affected diagnostic accuracy and patients' anxiety levels during the diagnostic phase.All 759 women referred for same-day evaluation of suspicious breast lesions between November 2011-March 2013 were included. Diagnostic accuracy was assessed by linking all patients to the national pathology database to identify diagnostic discrepancies, in which case slides were reviewed. Patients' anxiety was measured in 127 patients by the State Trait and Anxiety Inventory on six moments during the diagnostic workup and changes over time (< = 1 week were analyzed by mixed effect models.Core-needle biopsy was indicated in 374/759 patients (49.3% and in 205/759 (27% patients, invasive or in situ cancer was found. Final diagnosis on the same day was provided for 606/759 (79.8% patients. Overall, 3/759 (0.4% discordant findings were identified. Anxiety levels decreased significantly over time from 45.2 to 30.0 (P = <0.001. Anxiety levels decreased from 44.4 to 25.9 (P = <0.001 for patients with benign disease, and remained unchanged for patients diagnosed with malignancies (48.6 to 46.7, P = 0.933. Time trends in anxiety were not affected by other patient or disease characteristics like age, education level or (family history of breast cancer.Same-day histological diagnosis is feasible in the vast majority of patients, without impairing diagnostic accuracy. Patients' anxiety rapidly decreased in patients with a benign diagnosis and remained constant in patients with malignancy.

  13. Providing High Quality Care in Low-Income Areas of Maryland: Definitions, Resources, and Challenges from Parents and Child Care Providers' Perspectives. Publication #2012-45

    Science.gov (United States)

    Forry, Nicole; Simkin, Shana; Wessel, Julia; Rodrigues, Katherine

    2012-01-01

    Early life experiences are critical to a child's development. Research has shown that, for a variety of reasons, children born into low-income families are at a disadvantage when compared to their higher-income peers. Fortunately, research has also shown a positive association between high quality child care and the academic and social-emotional…

  14. Diagnostic accuracy of high-risk HPV genotyping in women with high-grade cervical lesions: evidence for improving the cervical cancer screening strategy in China.

    Science.gov (United States)

    Xu, Huihui; Lin, Aifen; Shao, Xiujuan; Shi, Weiwu; Zhang, Yang; Yan, Weihua

    2016-12-13

    Currently, clinical data for primary HPV screening alone are lacking in China. Here, we evaluate cervical cancer screening with primary HPV genotyping, as well as possible future screening strategy. Overall, high-risk HPV (hrHPV) prevalence was 18.2% among hospital-based population in Taizhou area. For cervical intraepithelial neoplasia 2 or worse (CIN2+), the sensitivity of primary hrHPV genotyping strategy and current cervical cancer screening strategy were 93.5%, and 71.1%, respectively; whereas the specificity was 17.5%, and 62.4%, respectively. Current cervical screening strategy had slightly higher positive predictive values (28.4%) for CIN2+ than hrHPV genotyping strategy (21.9%), whereas primary hrHPV genotyping strategy demonstrated higher negative predictive values (94.7%) than current cervical screening strategy (91.1%). Compared to HPV35/39/45/51/56/59/66/68 genotypes, the odds ratios (OR) for CIN2+ in HPV16/18/31/33/52/58 infection women were 3.2 (95% confidence interval [CI] 2.3-4.1). Primary hrHPV genotyping strategy provides a better predictive value than HPV16/18 genotyping alone in guiding the clinical management of the current cervical cancer screening. HPV testing without adjunctive cytology may be sufficiently sensitive for primary cervical cancer screening.

  15. {sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Thomas, E-mail: thomas.carlier@chu-nantes.fr [Department of Nuclear Medicine, University Hospital of Nantes, Place Alexis Ricordeau, Nantes 44093, France and CRCNA–UMR 892 INSERM 6299 CNRS, 8 quai Moncousu BP 70721, Nantes 44007 (France); Willowson, Kathy P. [Institute of Medical Physics, University of Sydney, Camperdown, New South Wales 2006 (Australia); Fourkal, Eugene [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Bailey, Dale L. [Faculty of Health Sciences, University of Sydney, Lidcombe 2141, Australia and Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, New South Wales 2065 (Australia); Doss, Mohan [Department of Diagnostic Imaging, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States); Conti, Maurizio [Siemens Healthcare Molecular Imaging, 810 Innovation Drive, Knoxville, Tennessee 37932 (United States)

    2015-07-15

    Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely

  16. High-accuracy de novo assembly and SNP detection of chloroplast genomes using a SMRT circular consensus sequencing strategy.

    Science.gov (United States)

    Li, Qiushi; Li, Ying; Song, Jingyuan; Xu, Haibin; Xu, Jiang; Zhu, Yingjie; Li, Xiwen; Gao, Huanhuan; Dong, Linlin; Qian, Jun; Sun, Chao; Chen, Shilin

    2014-12-01

    A circular consensus sequencing (CCS) strategy involving single molecule, real-time (SMRT) DNA sequencing technology was applied to de novo assembly and single nucleotide polymorphism (SNP) detection of chloroplast genomes. Chloroplast DNA was purified from enriched chloroplasts of pooled individuals to construct a shotgun library for each species. The sequencing reactions were performed on a PacBio RS platform. CCS sub-reads were generated from polymerase reads that passed the native dumbbell-shaped DNA templates multiple times. The complete chloroplast genome sequence was generated by mapping all reads to the draft sequence constructed in a step-by-step manner. The full-chain, PCR-free approach eliminates the possible context-specific biases in library construction and sequencing reaction. The chloroplast genome was easily and completely assembled using the data generated from one SMRT Cell without requiring a reference genome. Comparisons of the three assembled Fritillaria genomes to 34.1 kb of validation Sanger sequences revealed 100% concordance, and the detected intraspecies SNPs at a minimum variant frequency of 15% were all confirmed. This simple approach with potential for parallel sequencing yields high-quality chloroplast genomes for sensitive SNP detection and comparative analyses. We recommend this approach for its powerful applicability for evolutionary genetics and genomics studies in plants based on the sequences of chloroplast genomes. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  17. arXiv Interferometer-based high-accuracy white light measurement of neutral rubidium density and gradient at AWAKE

    CERN Document Server

    Batsch, Fabian; Oez, Erdem; Moody, Joshua; Gschwendtner, Edda; Caldwell, Allen; Muggli, Patric

    The AWAKE experiment requires an automated online rubidium (Rb) plasma density and gradient diagnostic for densities between 1 and 10$\\cdot$10$^{14}$ cm$^{-3}$. A linear density gradient along the plasma source at the percent level may be useful to improve the electron acceleration process. Because of full laser ionization of Rb vapor to Rb$^{+}$ within a radius of 1 mm, the plasma density equals the vapor density. We measure the Rb vapor densities at both ends of the source, with high precision using, white light interferometry. At either source end, broadband laser light passes a remotely controlled Mach-Zehnder interferometer built out of single mode fibers. The resulting interference signal, influenced by dispersion in the vicinity of the Rb D1 and D2 transitions, is dispersed in wavelength by a spectrograph. Fully automated Fourier-based signal conditioning and a fit algorithm yield the density with an uncertainty between the measurements at both ends of 0.11 to 0.46 $\\%$ over the entire density range. T...

  18. Assessment of geometry in 2D immune systems using high accuracy laser-based bioprinting techniques (Conference Presentation)

    Science.gov (United States)

    Lauzurica, Sara; Márquez, Andrés.; Molpeceres, Carlos; Notario, Laura; Gómez-Fontela, Miguel; Lauzurica, Pilar

    2017-02-01

    The immune system is a very complex system that comprises a network of genetic and signaling pathways subtending a network of interacting cells. The location of the cells in a network, along with the gene products they interact with, rules the behavior of the immune system. Therefore, there is a great interest in understanding properly the role of a cell in such networks to increase our knowledge of the immune system response. In order to acquire a better understanding of these processes, cell printing with high spatial resolution emerges as one of the promising approaches to organize cells in two and three-dimensional patterns to enable the study the geometry influence in these interactions. In particular, laser assisted bio-printing techniques using sub-nanosecond laser sources have better characteristics for application in this field, mainly due to its higher spatial resolution, cell viability percentage and process automation. This work presents laser assisted bio-printing of antigen-presenting cells (APCs) in two-dimensional geometries, placing cellular components on a matrix previously generated on demand, permitting to test the molecular interactions between APCs and lymphocytes; as well as the generation of two-dimensional structures designed ad hoc in order to study the mechanisms of mobilization of immune system cells. The use of laser assisted bio-printing, along with APCs and lymphocytes emulate the structure of different niches of the immune system so that we can analyse functional requirement of these interaction.

  19. High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor.

    Science.gov (United States)

    Liang, Xin M; Sekar, Praveen K; Zhao, Gang; Zhou, Xiaoming; Shu, Zhiquan; Huang, Zhongping; Ding, Weiping; Zhang, Qingchuan; Gao, Dayong

    2015-05-20

    An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Despite the previous belief, system calibration constant was observed to be highly temperature-dependent. Dynamic thermal conductivity response during cooling (40 °C to -40 °C) was observed using the miniaturized single tip sensor for various concentrations of CPAs, i.e., glycerol, ethylene glycol and dimethyl sulfoxide. Chicken breast, chicken skin, porcine limb, and bovine liver were assayed to investigate the effect of anatomical heterogeneity on thermal conductivity using the arrayed multi-tip sensor at 20 °C. Experimental results revealed distinctive differences in localized thermal conductivity, which suggests the use of approximated or constant property values is expected to bring about results with largely inflated uncertainties when investigating bio-heat transfer mechanisms and/or performing sophisticated thermal modeling with complex biological tissues. Overall, the presented micro thermal sensor with automated data analysis algorithm is a promising approach for direct thermal conductivity measurement of aqueous solutions and soft biomaterials and is of great value to cryopreservation of tissues, hyperthermia or cryogenic, and other thermal-based clinical diagnostics and treatments.

  20. High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor

    Science.gov (United States)

    Liang, Xin M.; Sekar, Praveen K.; Zhao, Gang; Zhou, Xiaoming; Shu, Zhiquan; Huang, Zhongping; Ding, Weiping; Zhang, Qingchuan; Gao, Dayong

    2015-01-01

    An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Despite the previous belief, system calibration constant was observed to be highly temperature-dependent. Dynamic thermal conductivity response during cooling (40 °C to –40 °C) was observed using the miniaturized single tip sensor for various concentrations of CPAs, i.e., glycerol, ethylene glycol and dimethyl sulfoxide. Chicken breast, chicken skin, porcine limb, and bovine liver were assayed to investigate the effect of anatomical heterogeneity on thermal conductivity using the arrayed multi-tip sensor at 20 °C. Experimental results revealed distinctive differences in localized thermal conductivity, which suggests the use of approximated or constant property values is expected to bring about results with largely inflated uncertainties when investigating bio-heat transfer mechanisms and/or performing sophisticated thermal modeling with complex biological tissues. Overall, the presented micro thermal sensor with automated data analysis algorithm is a promising approach for direct thermal conductivity measurement of aqueous solutions and soft biomaterials and is of great value to cryopreservation of tissues, hyperthermia or cryogenic, and other thermal-based clinical diagnostics and treatments. PMID:25993037

  1. The patient-provider relationship as experienced by a diverse sample of highly adherent HIV-infected people.

    Science.gov (United States)

    Brion, John

    2014-01-01

    Qualitative interviews with 23 HIV-infected people who self-reported high-level adherence to antiretroviral therapy were used to examine the process by which they came to accept their HIV infection and engage in high-level adherence behaviors. A major theme that emerged during data analysis was the importance of the patient-provider relationship. The quality of the relationship between patient and provider emerged as an important component of working through early struggles with diagnosis and the on-going struggles of living with a chronic illness. A variety of factors impacting the patient-provider relationship emerged as subthemes. What can be taken from this study is the importance of the patient-provider relationship in the effective self-management of HIV infection. Additionally, several specific behaviors can enhance the patient-provider relationship and help assure movement toward patient acceptance of the illness and engagement in high-level adherence behaviors. Copyright © 2014 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  2. A feedback system in residency to evaluate CanMEDS roles and provide high-quality feedback : Exploring its application

    NARCIS (Netherlands)

    Renting, Nienke; Gans, Rijk O. B.; Borleffs, Jan C. C.; Van Der Wal, Martha A.; Jaarsma, A. Debbie C.; Cohen-Schotanus, Janke

    Introduction: Residents benefit from regular, high quality feedback on all CanMEDS roles during their training. However, feedback mostly concerns Medical Expert, leaving the other roles behind. A feedback system was developed to guide supervisors in providing feedback on CanMEDS roles. We analyzed

  3. Accuracy of high-field intraoperative MRI in the detectability of residual tumor in glioma grade IV resections

    Energy Technology Data Exchange (ETDEWEB)

    Hesselmann, Volker; Mager, Ann-Kathrin [Asklepios-Klinik Nord, Hamburg (Germany). Radiology/Neurologie; Goetz, Claudia; Kremer, Paul [Asklepios-Klinik Nord, Hamburg (Germany). Dept. of Neurosurgery; Detsch, Oliver [Asklepios-Klinik Nord, Hamburg (Germany). Dept. of Anaesthesiology and Intensive Care Medicine; Theisgen, Hannah-Katharina [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Dept. of Neurosurgery; Friese, Michael; Gottschalk, Joachim [Asklepios-Klinik Nord, Hamburg (Germany). Dept. of Pathology and Neuropathology; Schwindt, Wolfram [Univ. Hospital Muenster (Germany). Dept. of Clinical Radiology

    2017-06-15

    To assess the sensitivity/specificity of tumor detection by T1 contrast enhancement in intraoperative MRI (ioMRI) in comparison to histopathological assessment as the gold standard in patients receiving surgical resection of grade IV glioblastoma. 68 patients with a primary or a recurrent glioblastoma scheduled for surgery including fluorescence guidance and neuronavigation were included (mean age: 59 years, 26 female, 42 male patients). The ioMRI after the first resection included transverse FLAIR, DWI, T2-FFE and T1 - 3 d FFE ± GD-DPTA. The second resection was performed whenever residual contrast-enhancing tissue was detected on ioMRI. Resected tissue samples were histopathologically evaluated (gold standard). Additionally, we evaluated the early postoperative MRI scan acquired within 48 h post-OP for remaining enhancing tissue and compared them with the ioMRI scan. In 43 patients ioMRI indicated residual tumorous tissue, which could be confirmed in the histological specimens of the second resection. In 16 (4 with recurrent, 12 with primary glioblastoma) cases, ioMRI revealed truly negative results without residual tumor and follow-up MRI confirmed complete resection. In 7 cases (3 with recurrent, 4 with primary glioblastoma) ioMRI revealed a suspicious result without tumorous tissue in the histopathological workup. In 2 (1 for each group) patients, residual tumorous tissue was detected in spite of negative ioMRI. IoMRI had a sensitivity of 95 % (94 % recurrent and 96 % for primary glioblastoma) and a specificity of 69.5 % (57 % and 75 %, respectively). The positive predictive value was 86 % (84 % for recurrent and 87 % for primary glioblastoma), and the negative predictive value was 88 % (80 % and 92 %, respectively). ioMRI is effective for detecting remaining tumorous tissue after glioma resection. However, scars and leakage of contrast agent can be misleading and limit specificity. Intraoperative MRI (ioMRI) presents with a high sensitivity for residual

  4. Partially hydrolyzed guar gum characterization and sensitive quantification in food matrices by high performance anion exchange chromatography with pulsed amperometric detection--validation using accuracy profile.

    Science.gov (United States)

    Mercier, G; Campargue, C

    2012-11-02

    Interest concerning functional ingredients and especially dietary fibres has been growing in recent years. At the same time, the variety of ingredient accepted as dietary fibres and their mixing at low level in complex matrices have considerably complicated their quantitative analysis by approved AOAC methods. These reasons have led to the specific development of an innovative analytical method performed by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) to detect and quantify partially hydrolyzed guar gum (PHGG) in fruit preparation and dairy matrices. The analytical methodology was divided in two steps which could be deployed separately or in conjunction. The first, consists in a complete characterization of PHGG by size exclusion chromatography (SEC) with multi-angle light scattering and refractive index detection and HPAEC-PAD to determine its physico-chemical properties and galactomannans content, and the second step is the development of a new HPAEC-PAD method for PHGG direct quantification in complex matrices (dairy product). Validation in terms of detection and quantification limits, linearity of the analytical range, average accuracy (recovery, trueness) and average uncertainty were statistically carried out with accuracy profile. Overall, this new chromatographic method has considerably improved the possibility to quantify without fractionation treatment, low level of dietary fibres emerging from specific galactomannans, in complex matrices and many foodstuffs. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Cause and Cure-Deterioration in Accuracy of CFD Simulations with Use of High-Aspect-Ratio Triangular/Tetrahedral Grids

    Science.gov (United States)

    Chang, Sin-Chung; Chang, Chau-Lyan; Venkatachari, Balaji

    2017-01-01

    In the multi-dimensional space-time conservation element and solution element16 (CESE) method, triangles and tetrahedral mesh elements turn out to be the most natural building blocks for 2D and 3D spatial grids, respectively. As such, the CESE method is naturally compatible with the simplest 2D and 3D unstructured grids and thus can be easily applied to solve problems with complex geometries. However, because (a) accurate solution of a high-Reynolds number flow field near a solid wall requires that the grid intervals along the direction normal to the wall be much finer than those in a direction parallel to the wall and, as such, the use of grid cells with extremely high aspect ratio (103 to 106) may become mandatory, and (b) unlike quadrilateral hexahedral grids, it is well-known that accuracy of gradient computations involving triangular tetrahedral grids tends to deteriorate rapidly as cell aspect ratio increases. As a result, the use of triangular tetrahedral grid cells near a solid wall has long been deemed impractical by CFD researchers. In view of (a) the critical role played by triangular tetrahedral grids in the CESE development, and (b) the importance of accurate resolution of high-Reynolds number flow field near a solid wall, as will be presented in the main paper, a comprehensive and rigorous mathematical framework that clearly identifies the reasons behind the accuracy deterioration as described above has been developed for the 2D case involving triangular cells. By avoiding the pitfalls identified by the 2D framework, and its 3D extension, it has been shown numerically.

  6. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  7. An Efficient Vector-Raster Overlay Algorithm for High-Accuracy and High-Efficiency Surface Area Calculations of Irregularly Shaped Land Use Patches

    Directory of Open Access Journals (Sweden)

    Peng Xie

    2017-05-01

    Full Text Available The Earth’s surface is uneven, and conventional area calculation methods are based on the assumption that the projection plane area can be obtained without considering the actual undulation of the Earth’s surface and by simplifying the Earth’s shape to be a standard ellipsoid. However, the true surface area is important for investigating and evaluating land resources. In this study, the authors propose a new method based on an efficient vector-raster overlay algorithm (VROA-based method to calculate the surface areas of irregularly shaped land use patches. In this method, a surface area raster file is first generated based on the raster-based digital elevation model (raster-based DEM. Then, a vector-raster overlay algorithm (VROA is used that considers the precise clipping of raster cells using the vector polygon boundary. Xiantao City, Luotian County, and the Shennongjia Forestry District, which are representative of a plain landform, a hilly topography, and a mountain landscape, respectively, are selected to calculate the surface area. Compared with a traditional method based on triangulated irregular networks (TIN-based method, our method significantly reduces the processing time. In addition, our method effectively improves the accuracy compared with another traditional method based on raster-based DEM (raster-based method. Therefore, the method satisfies the requirements of large-scale engineering applications.

  8. Test of the FDTD accuracy in the analysis of the scattering resonances associated with high-Q whispering-gallery modes of a circular cylinder.

    Science.gov (United States)

    Boriskin, Artem V; Boriskina, Svetlana V; Rolland, Anthony; Sauleau, Ronan; Nosich, Alexander I

    2008-05-01

    Our objective is the assessment of the accuracy of a conventional finite-difference time-domain (FDTD) code in the computation of the near- and far-field scattering characteristics of a circular dielectric cylinder. We excite the cylinder with an electric or magnetic line current and demonstrate the failure of the two-dimensional FDTD algorithm to accurately characterize the emission rate and the field patterns near high-Q whispering-gallery-mode resonances. This is proven by comparison with the exact series solutions. The computational errors in the emission rate are then studied at the resonances still detectable with FDTD, i.e., having Q-factors up to 10(3).

  9. Development of X-Y Servo Pneumatic-Piezoelectric Hybrid Actuators for Position Control with High Response, Large Stroke and Nanometer Accuracy

    Directory of Open Access Journals (Sweden)

    Mao-Hsiung Chiang

    2010-03-01

    Full Text Available This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm and nanometer accuracy (20 nm. In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.

  10. Multiplex Immunochips for High-Accuracy Detection of AFP-L3% Based on Surface-Enhanced Raman Scattering: Implications for Early Liver Cancer Diagnosis.

    Science.gov (United States)

    Ma, Hao; Sun, Xiaoying; Chen, Lei; Cheng, Weina; Han, Xiao Xia; Zhao, Bing; He, Chengyan

    2017-09-05

    α-Fetoprotein (AFP) is an important tumor biomarker. In particular, the overexpression of AFP-L3 is associated with hepatocellular carcinoma (HCC). Accordingly, several hospitals have begun to employ the ratio of AFP-L3 to the total AFP level (AFP-L3%) as new diagnostic evidence for HCC owing to its high diagnostic accuracy. However, current methods of detection for AFP and AFP-L3 are time-consuming, require multiple samples, and lack in sensitivity and specificity. Herein, we present a novel concept for the early diagnosis of HCC based on the combination of Raman frequency shift and intensity change, and developed surface-enhanced Raman scattering (SERS)-based immunochips via AFP-L3%. In the first step of the study, the frequency shift of 4-mercaptobenzoic acid (MBA) was applied for the quantitative determination of total AFP based on the AFP and anti-AFP interaction on MBA-modified silver chips. 5,5-Dithiobis(succinimidyl-2-nitrobenzoate) (DSNB)-modified immunogold was then incorporated with AFP-L3 antibodies for sandwich immunoreaction on the chips. As a result, we found that a typical Raman band intensity of DSNB presented an exponential linear relationship with the concentration of AFP-L3. Thus, the AFP-L3% can be calculated according to the concentrations of AFP-L3 and total AFP. The most important advantage of the proposed method is the combination of AFP-L3% and frequency shifts of SERS, which exhibits excellent reproducibility and high accuracy, and significantly simplifies the conventional detection procedure of AFP-L3%. Application of the proposed method with the serum of patients with HCC demonstrated its great potential in early liver cancer diagnosis.

  11. High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4 using the cavity ring-down spectroscopy (CRDS technique

    Directory of Open Access Journals (Sweden)

    V. Y. Chow

    2010-03-01

    Full Text Available High-accuracy continuous measurements of greenhouse gases (CO2 and CH4 during the BARCA (Balanço Atmosférico Regional de Carbono na Amazônia phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS technique. This analyzer was flown without a drying system or any in-flight calibration gases. Water vapor corrections associated with dilution and pressure-broadening effects for CO2 and CH4 were derived from laboratory experiments employing measurements of water vapor by the CRDS analyzer. Before the campaign, the stability of the analyzer was assessed by laboratory tests under simulated flight conditions. During the campaign, a comparison of CO2 measurements between the CRDS analyzer and a nondispersive infrared (NDIR analyzer on board the same aircraft showed a mean difference of 0.22±0.09 ppm for all flights over the Amazon rain forest. At the end of the campaign, CO2 concentrations of the synthetic calibration gases used by the NDIR analyzer were determined by the CRDS analyzer. After correcting for the isotope and the pressure-broadening effects that resulted from changes of the composition of synthetic vs. ambient air, and applying those concentrations as calibrated values of the calibration gases to reprocess the CO2 measurements made by the NDIR, the mean difference between the CRDS and the NDIR during BARCA was reduced to 0.05±0.09 ppm, with the mean standard deviation of 0.23±0.05 ppm. The results clearly show that the CRDS is sufficiently stable to be used in flight without drying the air or calibrating in flight and the water corrections are fully adequate for high-accuracy continuous airborne measurements of CO2 and CH4.

  12. Physicians cite hurdles ranging from lack of coverage to poor communication in providing high-quality care to latinos.

    Science.gov (United States)

    Vargas Bustamante, Arturo; Chen, Jie

    2011-10-01

    We surveyed physicians about their ability to provide high-quality care to patients from diverse ethnic backgrounds. Primarily, we wanted to explore the challenges faced by physicians treating Latino patients compared to physicians whose patients were primarily white and non-Latino. We found that physicians treating Latinos, particularly those who worked in primary care in comparison to specialists, were less likely than physicians treating primarily white patients to believe in their ability to provide high-quality care. They cited problems of inadequate time with patients, patients' ability to pay, patients' nonadherence to recommended treatment, difficulties communicating with patients, relative lack of specialist availability, and lack of timely transmission of reports among physicians. Insurance expansions and complementary reforms mandated by the Affordable Care Act of 2010 and other recent legislation should aid physicians in closing some of these gaps in quality.

  13. INTRODUCING NOVEL GENERATION OF HIGH ACCURACY CAMERA OPTICAL-TESTING AND CALIBRATION TEST-STANDS FEASIBLE FOR SERIES PRODUCTION OF CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Nekouei Shahraki

    2015-12-01

    Full Text Available The recent advances in the field of computer-vision have opened the doors of many opportunities for taking advantage of these techniques and technologies in many fields and applications. Having a high demand for these systems in today and future vehicles implies a high production volume of video cameras. The above criterions imply that it is critical to design test systems which deliver fast and accurate calibration and optical-testing capabilities. In this paper we introduce new generation of test-stands delivering high calibration quality in single-shot calibration of fisheye surround-view cameras. This incorporates important geometric features from bundle-block calibration, delivers very high (sub-pixel calibration accuracy, makes possible a very fast calibration procedure (few seconds, and realizes autonomous calibration via machines. We have used the geometrical shape of a Spherical Helix (Type: 3D Spherical Spiral with special geometrical characteristics, having a uniform radius which corresponds to the uniform motion. This geometrical feature was mechanically realized using three dimensional truncated icosahedrons which practically allow the implementation of a spherical helix on multiple surfaces. Furthermore the test-stand enables us to perform many other important optical tests such as stray-light testing, enabling us to evaluate the certain qualities of the camera optical module.

  14. Diagnostic accuracy of sensitive or high-sensitive troponin on presentation for myocardial infarction: a meta-analysis and systematic review

    Directory of Open Access Journals (Sweden)

    Sethi A

    2014-07-01

    Full Text Available Ankur Sethi,1 Anurag Bajaj,2 Gurveen Malhotra,1 Rohit R Arora,1 Sandeep Khosla1 1Department of Medicine, Division of Cardiology, Rosalind Franklin University of Medicine and Science, North Chicago, IL, USA; 2Department of Medicine, Wright Center of Graduate Medical Education, Scranton, PA, USA Background: Recently, high-sensitive troponin (hsTrop assays consistent with professional societies' recommendations became available. We aimed to summarize the evidence on the diagnostic accuracy of hsTrop on presentation. Methods: We searched electronic databases for studies evaluating the diagnostic accuracy of hsTrop in suspected acute coronary syndrome (ACS patients. Random effect meta-analyses and meta-regression were performed. Primary and secondary analyses were restricted to studies using conventional Trop and hsTrop in the reference standard, respectively. Results: Fifteen studies with a total of 8,628 patients met the inclusion criteria for the primary analysis. hsTrop T (Hoffman-La Roche Ltd and hsTrop I (Siemens had sensitivities of 0.89 (95% confidence interval [CI]: 0.86–0.91 and 0.90 (95% CI: 0.87–0.92 and specificities of 0.79 (95% CI: 0.77–0.80 and 0.89 (95% CI: 0.87–0.90, respectively. There was no statistically significant difference in the area under the curve between hsTrop (95% CI: 0.920 and conventional Trop (95% CI: 0.929 at the 99th percentile (P=0.62. hsTrop at the level of detection had a sensitivity of 0.97 (95% CI: 0.96–0.98 and a specificity of 0.41 (95% CI: 0.40–0.42. The studies using a cut-off at coefficient of variance <10% as opposed to the 99th percentile for the conventional assay used for diagnosis reported higher diagnostic accuracy (relative diagnostic odds ratio =2.13, P=0.02. Five studies were included in the secondary analysis; hsTrop T (Hoffman-La Roche Ltd had a sensitivity of 0.91 (95% CI: 0.89–0.93 and a specificity of 0.67 (95% CI: 0.63–0.70. There was significant heterogeneity among the

  15. Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry.

    Science.gov (United States)

    Alagar, Ananda Giri Babu; Mani, Ganesh Kadirampatti; Karunakaran, Kaviarasu

    2016-01-08

    Small fields smaller than 4 × 4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model-based algorithms, X-ray Voxel Monte Carlo (XVMC) from Monaco, Superposition (SP) from CMS-Xio, AcurosXB (AXB) and analytical anisotropic algorithm (AAA) from Eclipse are tested against the measurement. Measurements are done using Exradin W1 plastic scintillator in Solid Water phantom with heterogeneities like air, lung, bone, and aluminum, irradiated with 6 and 15 MV photons of square field size ranging from 1 to 4 cm2. Each heterogeneity is introduced individually at two different depths from depth-of-dose maximum (Dmax), one setup being nearer and another farther from the Dmax. The central axis percentage depth-dose (CADD) curve for each setup is measured separately and compared with the TPS algorithm calculated for the same setup. The percentage normalized root mean squared deviation (%NRMSD) is calculated, which represents the whole CADD curve's deviation against the measured. It is found that for air and lung heterogeneity, for both 6 and 15 MV, all algorithms show maximum deviation for field size 1 × 1 cm2 and gradually reduce when field size increases, except for AAA. For aluminum and bone, all algorithms' deviations are less for 15 MV irrespective of setup. In all heterogeneity setups, 1 × 1 cm2 field showed maximum deviation, except in 6MV bone setup. All algorithms in the study, irrespective of energy and field size, when any heterogeneity is nearer to Dmax, the dose deviation is higher compared to the same heterogeneity far from the Dmax. Also, all algorithms show maximum deviation in lower-density materials compared to high-density materials.

  16. The costs and cost-efficiency of providing food through schools in areas of high food insecurity.

    Science.gov (United States)

    Gelli, Aulo; Al-Shaiba, Najeeb; Espejo, Francisco

    2009-03-01

    The provision of food in and through schools has been used to support the education, health, and nutrition of school-aged children. The monitoring of financial inputs into school health and nutrition programs is critical for a number of reasons, including accountability, transparency, and equity. Furthermore, there is a gap in the evidence on the costs, cost-efficiency, and cost-effectiveness of providing food through schools, particularly in areas of high food insecurity. To estimate the programmatic costs and cost-efficiency associated with providing food through schools in food-insecure, developing-country contexts, by analyzing global project data from the World Food Programme (WFP). Project data, including expenditures and number of schoolchildren covered, were collected through project reports and validated through WFP Country Office records. Yearly project costs per schoolchild were standardized over a set number of feeding days and the amount of energy provided by the average ration. Output metrics, such as tonnage, calories, and micronutrient content, were used to assess the cost-efficiency of the different delivery mechanisms. The average yearly expenditure per child, standardized over a 200-day on-site feeding period and an average ration, excluding school-level costs, was US$21.59. The costs varied substantially according to choice of food modality, with fortified biscuits providing the least costly option of about US$11 per year and take-home rations providing the most expensive option at approximately US$52 per year. Comparisons across the different food modalities suggested that fortified biscuits provide the most cost-efficient option in terms of micronutrient delivery (particularly vitamin A and iodine), whereas on-site meals appear to be more efficient in terms of calories delivered. Transportation and logistics costs were the main drivers for the high costs. The choice of program objectives will to a large degree dictate the food modality

  17. The perceptions of teachers and principals toward providing additional compensation to teachers in high-need subject areas

    Science.gov (United States)

    Longing, Jeffrey Lucian

    The purpose of this study was to determine possible differences in the perceptions of teachers teaching in high-need areas (i.e., math, science, special education, etc.) and teachers not teaching in high-need areas, (i.e., business education, physical education, etc.) as defined by the states of Arkansas and Louisiana, regarding higher compensation for high-need teachers. In addition, possible perception differences among principals and teachers were determined. The independent variables consisted of gender, position held, years of certified experience, and certification areas. The dependent variable was the perceptions of the participants on providing higher compensation for high-need teachers in order to attract and retain them. The data for all variables were collected using the Teacher Compensation Survey. The sample for this study was limited to teachers, grades 9 through 12, and principals of public high schools in south Arkansas and north Louisiana. Forty-four school districts in south Arkansas (Arkansas Department of Education, 2008a) and north Louisiana (Louisiana Department of Education, 2008a) met the criteria for this study. Twenty-two superintendents gave permission for their districts to participate in the research. A sample of 849 teachers and 38 principals were identified in these districts. Surveys were returned from 350 teachers, creating a 41% response rate. When the 31 principals that returned surveys were added to the total population, the response rate increased to 43% with 381 of the 887 surveyed responding. However, 42 of the teachers and two of the principals skipped some of the questions on the survey and were not included in the study. The researcher used a One-Way ANOVA and independent t-tests to determine the presence of statistical differences at the .05 level. The data showed that most math and science teachers agreed that high-need teachers should be compensated at a higher rate than teachers not teaching in high-need areas. The data

  18. Abstinence and teenagers: prevention counseling practices of health care providers serving high-risk patients in the United States.

    Science.gov (United States)

    Harper, Cynthia C; Henderson, Jillian T; Schalet, Amy; Becker, Davida; Stratton, Laura; Raine, Tina R

    2010-06-01

    Abstinence-only education has had little demonstrable impact on teenagers' sexual behaviors, despite significant policy and funding efforts. Given the struggle over resources to improve teenagers' reproductive health outcomes, the views of clinicians serving teenagers at high risk for unintended pregnancy and STDs merit particular attention. In 2005, a qualitative study with 31 clinicians serving low-income, at-risk patients was conducted. A semistructured interview guide was used to ask clinicians about adolescent pregnancy, HIV and STD prevention counseling, and when they include abstinence. Thematic content analysis was used to examine the content of the counseling and the techniques used in different situations. Providers reported offering comprehensive counseling, presenting abstinence as a choice for teenagers, along with information about contraceptives and condoms. Several providers mentioned that with young, sexually inexperienced teenagers, they discuss delaying sexual activity and suggest other ways to be affectionate, while giving information on condoms. Providers explained how they assess whether teenagers feel ready to be sexually active and try to impart skills for healthy relationships. Some described abstinence as giving teenagers a way to opt out of unwanted sexual activity. Many support abstinence if that is the patient's desire, but routinely dispense condoms and contraceptives. Overall, providers did not give abstinence counseling as a rigid categorical concept in their preventive practices, but as a health tool to give agency to teenagers within a harm reduction framework. Their approach may be informative for adolescent policies and programs in the future.

  19. Physicians' assessments of their ability to provide high-quality care in a changing health care system.

    Science.gov (United States)

    Reschovsky, J; Reed, M; Blumenthal, D; Landon, B

    2001-03-01

    With the growth of managed care, there are increasing concerns but inconclusive evidence regarding deterioration in the quality of medical care. To assess physicians' perceptions of their ability to provide high-quality care and explore what factors, including managed care, affect these perceptions. Bivariate and multivariate analyses of the Community Tracking Study Physician Survey, a cross-sectional, nationally representative telephone survey of 12,385 patient-care physicians conducted in 1996/1997. The response rate was 65%. Physicians who provide direct patient care for > or =20 h/wk, excluding federal employees and those in selected specialties. Level of agreement with 4 statements: 1 regarding overall ability to provide high-quality care and 3 regarding aspects of care delivery associated with quality. Between 21% and 31% of physicians disagreed with the quality statements. Specialists were generally 50% more likely than primary care physicians to express concerns about their ability to provide quality care. Generally, the number of managed care contracts, but not the percent of practice revenue from managed care, was negatively associated with perceived quality. Market-level managed care penetration independently affected physicians' perceptions. Practice setting affected perceptions of quality, with physicians in group settings less likely to express concerns than physicians in solo and 2-physician practices. Specific financial incentives and care management tools had limited positive or negative associations with perceived quality. Managed care involvement is only modestly associated with reduced perceptions of quality among physicians, with some specific tools enhancing perceived quality. Physicians may be able to moderate some negative effects of managed care by altering their practice arrangements.

  20. ExoMol molecular line lists XIX: high-accuracy computed hot line lists for H218O and H217O

    Science.gov (United States)

    Polyansky, Oleg L.; Kyuberis, Aleksandra A.; Lodi, Lorenzo; Tennyson, Jonathan; Yurchenko, Sergei N.; Ovsyannikov, Roman I.; Zobov, Nikolai F.

    2017-04-01

    Hot line lists for two isotopologues of water, H218O and H217O, are presented. The calculations employ newly constructed potential energy surfaces (PES), which take advantage of a novel method for using the large set of experimental energy levels for H216O to give high-quality predictions for H218O and H217O. This procedure greatly extends the energy range for which a PES can be accurately determined, allowing an accurate prediction of higher lying energy levels than are currently known from direct laboratory measurements. This PES is combined with a high-accuracy, ab initio dipole moment surface of water in the computation of all energy levels, transition frequencies and associated Einstein A coefficients for states with rotational excitation up to J = 50 and energies up to 30 000 cm-1. The resulting HotWat78 line lists complement the well-used BT2 H216O line list. Full line lists are made available online as Supporting Information and at www.exomol.com.

  1. Seismic refraction analysis with high accuracy based on traveltime modeling; Basu keisan wo base to shita kussekiho jishin tansa kaiseki no koseidoka

    Energy Technology Data Exchange (ETDEWEB)

    Saito, H.; Hayashi, K. [OYO Corp., Tokyo (Japan)

    1996-05-01

    For the purpose of enhancing the efficiency of analytical processes so that those not equipped with high skill may perform a certain level of analysis and that analysis precision may be improved, some analytical techniques based on path calculation were examined. As the result, a flow of work has become feasible, wherein an early model is constructed by use of a tomography-assisted analysis to be accomplished automatedly and the result is then converted into a layer system with the velocity and thickness to be automatically corrected for the determination of the ultimate velocity layer section. Following this flow of work, almost all the parts of the work may be accomplished automatically once the travel time curve is completed. Furthermore, the calculated travel time obtained by this method can be easily compared with the observed travel time creating an opportunity to show the high reliability of this method, for this to be accepted as a standard for evaluating the accuracy of exploration. It has also been found that this method may be applied to more complicated structures which fail to satisfy the conditions for a structure to be treated by other methods such as `Hagiwara`s method.` 3 refs., 5 figs.

  2. High accuracy measurement of the $^{235}$U(n,f) reaction cross-section in the 10-30 keV neutron energy range

    CERN Multimedia

    The analysis of the neutron flux of n_TOF (in EAR1) revealed an anomaly in the 10-30 keV neutron energy range. While the flux extracted on the basis of the $^{6}$Li(n,t)$^{4}$He and $^{10}$B(n,$\\alpha$)$^{7}$Li reactions mostly agreed with each other and with the results of FLUKA simulations of the neutron beam, the one based on the $^{235}$U(n,f) reaction was found to be systematically lower, independently of the detection system used. A possible explanation is that the $^{235}$U(n,f) crosssection in that energy region, where in principle should be known with an uncertainty of 1%, may be systematically overestimated. Such a finding, which has a negligible influence on thermal reactors, would be important for future fast critical or subcritical reactors. Furthermore, its interest is more general, since the $^{235}$U(n,f) reaction is often used at that energy to determine the neutron flux, or as reference in measurements of fission cross section of other actinides. We propose to perform a high-accuracy, high-r...

  3. Comparing the accuracy of high-dimensional neural network potentials and the systematic molecular fragmentation method: A benchmark study for all-trans alkanes

    Science.gov (United States)

    Gastegger, Michael; Kauffmann, Clemens; Behler, Jörg; Marquetand, Philipp

    2016-05-01

    Many approaches, which have been developed to express the potential energy of large systems, exploit the locality of the atomic interactions. A prominent example is the fragmentation methods in which the quantum chemical calculations are carried out for overlapping small fragments of a given molecule that are then combined in a second step to yield the system's total energy. Here we compare the accuracy of the systematic molecular fragmentation approach with the performance of high-dimensional neural network (HDNN) potentials introduced by Behler and Parrinello. HDNN potentials are similar in spirit to the fragmentation approach in that the total energy is constructed as a sum of environment-dependent atomic energies, which are derived indirectly from electronic structure calculations. As a benchmark set, we use all-trans alkanes containing up to eleven carbon atoms at the coupled cluster level of theory. These molecules have been chosen because they allow to extrapolate reliable reference energies for very long chains, enabling an assessment of the energies obtained by both methods for alkanes including up to 10 000 carbon atoms. We find that both methods predict high-quality energies with the HDNN potentials yielding smaller errors with respect to the coupled cluster reference.

  4. Medical School Anatomy and Pathology Workshops for High School Students Enhance Learning and Provide Inspiration for Careers in Medicine

    Science.gov (United States)

    Fenderson, Bruce A.; Veloski, J. Jon; Livesey, Michael; Wojdon-Smith, Tracey

    2016-01-01

    “Anatomy and Pathology Workshop” is a cadaver-based outreach program that models medical education to large groups of high school students. This study was designed to evaluate the impact of this program on students’ knowledge of anatomy and interest in biomedical science. A total of 144 high school students participated in the workshop in 2015. Preworkshop and postworkshop assessments were administered to assess students’ learning. A postworkshop survey was conducted to solicit students’ reflections and feedback. It was found that student performance in the postworkshop examination (mean 78%) had significantly improved when compared to the performance in the preexamination (mean 54%), indicating that this program enhances learning. Students were also inspired to consider opportunities in medicine and allied health professions—97% indicated that they had a better understanding of medical education; 95% agreed that they had better understanding of the human body; 84% thought anatomy was interesting and exciting; and 62% of the students indicated that they looked forward to studying medicine or another health profession. Students rated the instructors highly—95% agreed that the instructors were professional and served as role models. Medical/graduate student instructors were also highly regarded by the high school students—96% thought it was valuable to have student instructors and 94% thought that student instructors were caring and enthusiastic about teaching. In summary, this study demonstrates that outreach programs provided by medical schools help young adults during their formative years by modeling professionalism, providing role models, enhancing learning, and encouraging many to consider opportunities in the health professions. PMID:28725784

  5. High accuracy of mesoscopic epi-fluorescence tomography for non-invasive quantitative volume determination of fluorescent protein-expressing tumours in mice

    Energy Technology Data Exchange (ETDEWEB)

    Abou-Elkacem, Lotfi; Doleschel, Dennis; Kiessling, Fabian; Lederle, Wiltrud [RWTH Aachen University, Department of Experimental Molecular Imaging, Medical Faculty, Aachen (Germany); Bjoern, Saskia; Ntziachristos, Vasilis; Schulz, Ralf [Technische Universitaet Muenchen and Helmholtz Zentrum Muenchen, Institute for Biological and Medical Imaging, Neuherberg (Germany); Hoffman, Robert M. [University of California and AntiCancer Inc., Department of Surgery, San Diego, CA (United States)

    2012-09-15

    To compare mesoscopic epi-fluorescence tomography (MEFT) and EPRI-illumination reflectance imaging (EPRI) for quantitative tumour size assessment in mice. Tumour xenografts of green/red fluorescent protein (GFP/RFP)-expressing colon cancer cells were measured using MEFT, EPRI, ultrasound (US) and micro computed tomography ({mu}CT) at day 14 post-injection (n = 6). Results from MEFT and EPRI were correlated with each other and with US and {mu}CT (reference methods). Tumour volumes were measured ex vivo by GFP and RFP fluorescence imaging on cryoslices and compared with the in vivo measurements. High correlation and congruency were observed between MEFT, US and {mu}CT (MEFT/US: GFP: r {sup 2} = 0.96; RFP: r {sup 2} = 0.97, both P < 0.05; MEFT/{mu}CT: GFP: r {sup 2} = 0.93; RFP: r {sup 2} = 0.90; both P < 0.05). Additionally, in vivo MEFT data were highly correlated and congruent with ex vivo cryoslice imaging results (GFP: r {sup 2} = 0.96; RFP: r {sup 2} = 0.99; both P < 0.05). In comparison, EPRI significantly overestimated tumour volumes (P < 0.05), although there was a significant correlation with US and {mu}CT (EPRI/US: GFP: r {sup 2} = 0.95; RFP: r {sup 2} = 0.94; both P < 0.05; EPRI/{mu}CT GFP: r {sup 2} = 0.86; RFP: r {sup 2} = 0.86; both P < 0.05). Fluorescence distribution reconstruction using MEFT affords highly accurate three-dimensional (3D) tumour volume data showing superior accuracy compared to EPRI. Thus, MEFT is a very suitable technique for quantitatively assessing fluorescence distribution in superficial tumours at high spatial resolution. (orig.)

  6. Fusion of lens-free microscopy and mobile-phone microscopy images for high-color-accuracy and high-resolution pathology imaging

    Science.gov (United States)

    Zhang, Yibo; Wu, Yichen; Zhang, Yun; Ozcan, Aydogan

    2017-03-01

    Digital pathology and telepathology require imaging tools with high-throughput, high-resolution and accurate color reproduction. Lens-free on-chip microscopy based on digital in-line holography is a promising technique towards these needs, as it offers a wide field of view (FOV >20 mm2) and high resolution with a compact, low-cost and portable setup. Color imaging has been previously demonstrated by combining reconstructed images at three discrete wavelengths in the red, green and blue parts of the visible spectrum, i.e., the RGB combination method. However, this RGB combination method is subject to color distortions. To improve the color performance of lens-free microscopy for pathology imaging, here we present a wavelet-based color fusion imaging framework, termed "digital color fusion microscopy" (DCFM), which digitally fuses together a grayscale lens-free microscope image taken at a single wavelength and a low-resolution and low-magnification color-calibrated image taken by a lens-based microscope, which can simply be a mobile phone based cost-effective microscope. We show that the imaging results of an H&E stained breast cancer tissue slide with the DCFM technique come very close to a color-calibrated microscope using a 40x objective lens with 0.75 NA. Quantitative comparison showed 2-fold reduction in the mean color distance using the DCFM method compared to the RGB combination method, while also preserving the high-resolution features of the lens-free microscope. Due to the cost-effective and field-portable nature of both lens-free and mobile-phone microscopy techniques, their combination through the DCFM framework could be useful for digital pathology and telepathology applications, in low-resource and point-of-care settings.

  7. Assessing the Accuracy of High Resolution Digital Surface Models Computed by PhotoScan® and MicMac® in Sub-Optimal Survey Conditions

    Directory of Open Access Journals (Sweden)

    Marion Jaud

    2016-06-01

    Full Text Available For monitoring purposes and in the context of geomorphological research, Unmanned Aerial Vehicles (UAV appear to be a promising solution to provide multi-temporal Digital Surface Models (DSMs and orthophotographs. There are a variety of photogrammetric software tools available for UAV-based data. The objective of this study is to investigate the level of accuracy that can be achieved using two of these software tools: Agisoft PhotoScan® Pro and an open-source alternative, IGN© MicMac®, in sub-optimal survey conditions (rugged terrain, with a large variety of morphological features covering a range of roughness sizes, poor GPS reception. A set of UAV images has been taken by a hexacopter drone above the Rivière des Remparts, a river on Reunion Island. This site was chosen for its challenging survey conditions: the topography of the study area (i involved constraints on the flight plan; (ii implied errors on some GPS measurements; (iii prevented an optimal distribution of the Ground Control Points (GCPs and; (iv was very complex to reconstruct. Several image processing tests are performed with different scenarios in order to analyze the sensitivity of each software package to different parameters (image quality, numbers of GCPs, etc.. When computing the horizontal and vertical errors within a control region on a set of ground reference targets, both methods provide rather similar results. A precision up to 3–4 cm is achievable with these software packages. The DSM quality is also assessed over the entire study area comparing PhotoScan DSM and MicMac DSM with a Terrestrial Laser Scanner (TLS point cloud. PhotoScan and MicMac DSM are also compared at the scale of particular features. Both software packages provide satisfying results: PhotoScan is more straightforward to use but its source code is not open; MicMac is recommended for experimented users as it is more flexible.

  8. HiRadMat at CERN/SPS - A dedicated facility providing high intensity beam pulses to material samples

    CERN Multimedia

    Charitonidis, N; Efthymiopoulos, I

    2014-01-01

    HiRadMat (High Radiation to Materials), constructed in 2011, is a facility at CERN designed to provide high‐intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, high power beam targets, collimators…) can be tested. The facility uses a 440 GeV proton beam extracted from the CERN SPS with a pulse length of up to 7.2 us, and with a maximum pulse energy of 3.4 MJ (3xE13 proton/pulse). In addition to protons, ion beams with energy of 440 GeV/charge and total pulse energy of 21 kJ can be provided. The beam parameters can be tuned to match the needs of each experiment. HiRadMat is not an irradiation facility where large doses on equipment can be accumulated. It is rather a test area designed to perform single pulse experiments to evaluate the effect of high‐intensity pulsed beams on materials or accelerator component assemblies in a controlled environment. The fa‐ cility is designed for a maximum of 1E16 protons per year, dist...

  9. Checking the predictive accuracy of basic symptoms against ultra high-risk criteria and testing of a multivariable prediction model: Evidence from a prospective three-year observational study of persons at clinical high-risk for psychosis.

    Science.gov (United States)

    Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A

    2017-09-01

    The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, Ppredict psychosis beyond mere chance (AUC=0.52, P=.730). Sensitivity and specificity were 0.83 and 0.47 for UHR, and 0.96 and 0.09 for BS. UHR plus BS achieved an AUC=0.66, with sensitivity and specificity of 0.75 and 0.56. In comparison, baseline antipsychotic medication yielded a predictive accuracy of AUC=0.62 (sensitivity=0.42; specificity=0.82). A multivariable prediction model comprising continuous measures of positive symptoms and verbal IQ achieved a substantially improved prognostic accuracy (AUC=0.85; sensitivity=0.86; specificity=0.85; positive predictive value=0.54; negative predictive value=0.97). We showed that BS have no predictive accuracy beyond chance, while UHR criteria poorly predict conversion to psychosis. Combining BS with UHR criteria did not improve the predictive accuracy of UHR alone. In contrast, dimensional measures of both positive symptoms and verbal IQ showed excellent prognostic validity. A critical re-thinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson

  10. Photosynthesis-dependent H2O2 transfer from chloroplasts to nuclei provides a high-light signalling mechanism.

    Science.gov (United States)

    Exposito-Rodriguez, Marino; Laissue, Pierre Philippe; Yvon-Durocher, Gabriel; Smirnoff, Nicholas; Mullineaux, Philip M

    2017-06-29

    Chloroplasts communicate information by signalling to nuclei during acclimation to fluctuating light. Several potential operating signals originating from chloroplasts have been proposed, but none have been shown to move to nuclei to modulate gene expression. One proposed signal is hydrogen peroxide (H2O2) produced by chloroplasts in a light-dependent manner. Using HyPer2, a genetically encoded fluorescent H2O2 sensor, we show that in photosynthetic Nicotiana benthamiana epidermal cells, exposure to high light increases H2O2 production in chloroplast stroma, cytosol and nuclei. Critically, over-expression of stromal ascorbate peroxidase (H2O2 scavenger) or treatment with DCMU (photosynthesis inhibitor) attenuates nuclear H2O2 accumulation and high light-responsive gene expression. Cytosolic ascorbate peroxidase over-expression has little effect on nuclear H2O2 accumulation and high light-responsive gene expression. This is because the H2O2 derives from a sub-population of chloroplasts closely associated with nuclei. Therefore, direct H2O2 transfer from chloroplasts to nuclei, avoiding the cytosol, enables photosynthetic control over gene expression.Multiple plastid-derived signals have been proposed but not shown to move to the nucleus to promote plant acclimation to fluctuating light. Here the authors use a fluorescent hydrogen peroxide sensor to provide evidence that H2O2 is transferred directly from chloroplasts to nuclei to control nuclear gene expression.

  11. Frequency of high-quality communication behaviors used by primary care providers of heterozygous infants after newborn screening.

    Science.gov (United States)

    Farrell, Michael H; Christopher, Stephanie A

    2013-02-01

    To examine the quality of communication likely to be experienced by parents when being first informed about how newborn screening identified heterozygous "carrier" status for cystic fibrosis or sickle cell disease. Primary care providers (PCPs) of infants found to have carrier status were telephoned over a 48-month period, and asked to rehearse with a standardized patient how they would inform the infants' parent(s). 214 rehearsal transcripts were abstracted using explicit criteria methods to measure the frequency of five categories of high-quality communication behaviors. Overall, PCPs used large amounts of jargon and failed to use high quality communication behaviors. On average, PCPs used 18.6 total jargon words (8.7 unique words), but explained 2.4 jargon words. The most frequent assessment of understanding was the close-ended version, although it was only seen in 129 of 214 transcripts. The most common organizing behavior was importance emphasis (121/214). Precautionary empathy was rare; the most frequent behavior was "instruction about emotion" (33/214). The limited use of high-quality communication behaviors in rehearsals raises concern about parental understanding, decision-making, and psychosocial outcomes after newborn screening. Measurement of specific behaviors may help PCPs to improve communication, and thereby improve the patient experience. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. High accuracy Land Use Land Cover (LULC maps for detecting agricultural drought effects in rainfed agro-ecosystems in central Mexico

    Directory of Open Access Journals (Sweden)

    Sierra-Soler Andres

    2015-09-01

    Full Text Available Satellite remote sensing provides a synoptic view of the land and a spatial context for measuring drought impacts, which have proved to be a valuable source of spatially continuous data with improved information for monitoring vegetation dynamics. Many studies have focused on detecting drought effects over large areas, given the wide availability of low-resolution images. In this study, however, the objective was to focus on a smaller area (1085 km2 using Landsat ETM+ images (multispectral resolution of 30 m and 15 m panchromatic, and to process very accurate Land Use Land Cover (LULC classification to determine with great precision the effects of drought in specific classes. The study area was the Tortugas-Tepezata sub watershed (Moctezuma River, located in the state of Hidalgo in central Mexico. The LULC classification was processed using a new method based on available ancillary information plus analysis of three single date satellite images. The newly developed LULC methodology developed produced overall accuracies ranging from 87.88% to 92.42%. Spectral indices for vegetation and soil/vegetation moisture were used to detect anomalies in vegetation development caused by drought; furthermore, the area of water bodies was measured and compared to detect changes in water availability for irrigated crops. The proposed methodology has the potential to be used as a tool to identify, in detail, the effects of drought in rainfed agricultural lands in developing regions, and it can also be used as a mechanism to prevent and provide relief in the event of droughts.

  13. Accuracy of a rapid diagnostic test on the diagnosis of malaria infection and of malaria - attributable fever during low and high transmission season in Burkina Faso

    Directory of Open Access Journals (Sweden)

    Tinto Halidou

    2010-07-01

    Full Text Available Abstract Background Malaria management policies currently recommend that the treatment should only be administered after laboratory confirmation. Where microscopy is not available, rapid diagnostic tests (RDTs are the usual alternative. Conclusive evidence is still lacking on the safety of a test-based strategy for children. Moreover, no formal attempt has been made to estimate RDTs accuracy on malaria-attributable fever. This study aims at estimating the accuracy of a RDT for the diagnosis of both malaria infection and malaria - attributable fever, in a region of Burkina Faso with a typically seasonal malaria transmission pattern. Methods Cross-sectional study. Subjects: all patients aged > 6 months consulting during the study periods. Gold standard for the diagnosis of malaria infection was microscopy. Gold standard for malaria-attributable fever was the number of fevers attributable to malaria, estimated by comparing parasite densities of febrile versus non-febrile subjects. Exclusion criteria: severe clinical condition needing urgent care. Results In the dry season, 186/852 patients with fever (22% and 213/1,382 patients without fever (15% had a Plasmodium falciparum infection. In the rainy season, this proportion was 841/1,317 (64% and 623/1,669 (37%, respectively. The attributable fraction of fever to malaria was 11% and 69%, respectively. The RDT was positive in 113/400 (28.3% fever cases in the dry season, and in 443/650 (68.2% in the rainy season. In the dry season, the RDT sensitivity and specificity for malaria infection were 86% and 90% respectively. In the rainy season they were 94% and 78% respectively. In the dry season, the RDT sensitivity and specificity for malaria-attributable fever were 94% and 75%, the positive predictive value (PPV was 9% and the negative predictive value (NPV was 99.8%. In the rainy season the test sensitivity for malaria-attributable fever was 97% and specificity was 55%. The PPV ranged from 38% for

  14. IEEE 802.15.4 Frame Aggregation Enhancement to Provide High Performance in Life-Critical Patient Monitoring Systems.

    Science.gov (United States)

    Akbar, Muhammad Sajjad; Yu, Hongnian; Cang, Shuang

    2017-01-28

    In wireless body area sensor networks (WBASNs), Quality of Service (QoS) provision for patient monitoring systems in terms of time-critical deadlines, high throughput and energy efficiency is a challenging task. The periodic data from these systems generates a large number of small packets in a short time period which needs an efficient channel access mechanism. The IEEE 802.15.4 standard is recommended for low power devices and widely used for many wireless sensor networks applications. It provides a hybrid channel access mechanism at the Media Access Control (MAC) layer which plays a key role in overall successful transmission in WBASNs. There are many WBASN's MAC protocols that use this hybrid channel access mechanism in variety of sensor applications. However, these protocols are less efficient for patient monitoring systems where life critical data requires limited delay, high throughput and energy efficient communication simultaneously. To address these issues, this paper proposes a frame aggregation scheme by using the aggregated-MAC protocol data unit (A-MPDU) which works with the IEEE 802.15.4 MAC layer. To implement the scheme accurately, we develop a traffic patterns analysis mechanism to understand the requirements of the sensor nodes in patient monitoring systems, then model the channel access to find the performance gap on the basis of obtained requirements, finally propose the design based on the needs of patient monitoring systems. The mechanism is initially verified using numerical modelling and then simulation is conducted using NS2.29, Castalia 3.2 and OMNeT++. The proposed scheme provides the optimal performance considering the required QoS.

  15. Barriers to provider-initiated testing and counselling for children in a high HIV prevalence setting: a mixed methods study.

    Directory of Open Access Journals (Sweden)

    Katharina Kranzer

    2014-05-01

    Full Text Available There is a substantial burden of HIV infection among older children in sub-Saharan Africa, the majority of whom are diagnosed after presentation with advanced disease. We investigated the provision and uptake of provider-initiated HIV testing and counselling (PITC among children in primary health care facilities, and explored health care worker (HCW perspectives on providing HIV testing to children.Children aged 6 to 15 y attending six primary care clinics in Harare, Zimbabwe, were offered PITC, with guardian consent and child assent. The reasons why testing did not occur in eligible children were recorded, and factors associated with HCWs offering and children/guardians refusing HIV testing were investigated using multivariable logistic regression. Semi-structured interviews were conducted with clinic nurses and counsellors to explore these factors. Among 2,831 eligible children, 2,151 (76% were offered PITC, of whom 1,534 (54.2% consented to HIV testing. The main reasons HCWs gave for not offering PITC were the perceived unsuitability of the accompanying guardian to provide consent for HIV testing on behalf of the child and lack of availability of staff or HIV testing kits. Children who were asymptomatic, older, or attending with a male or a younger guardian had significantly lower odds of being offered HIV testing. Male guardians were less likely to consent to their child being tested. 82 (5.3% children tested HIV-positive, with 95% linking to care. Of the 940 guardians who tested with the child, 186 (19.8% were HIV-positive.The HIV prevalence among children tested was high, highlighting the need for PITC. For PITC to be successfully implemented, clear legislation about consent and guardianship needs to be developed, and structural issues addressed. HCWs require training on counselling children and guardians, particularly male guardians, who are less likely to engage with health care services. Increased awareness of the risk of HIV infection

  16. Science Research 4: A New Curriculum Providing Student Mentorship and Teacher Training Facilitated by High School Students

    Science.gov (United States)

    Danch, J. M.; Aker, K.

    2013-12-01

    As part of a continuing comprehensive plan to include authentic scientific research in the science curricula of the Woodbridge Township School District, a new curriculum was developed to expanding the current 3-year Science Research Program to include a 4th year class. As with the previous 3 levels, the objectives of this curriculum include the development, implementation and dissemination of authentic scientific research by students. New objectives make use of the students advanced knowledge of the methods of science and electronic laboratory technology to provide mentorship to students performing scientific research or other inquiry-based science activities. Mentored students include those enrolled in high school Science Research 1, 8th Grade Honors Geoscience, and other high school science classes where scientific methods, inquiry-based learning and electronic data acquisition tools are utilized. Student mentors will also assist in the facilitation of a district-wide K-12 science symposium. The curriculum also calls for the creation of educational materials by students to enhance the teaching of scientific research and inquiry-based learning. Finally, students enrolled in Science Research 4 will conduct teacher-training sessions where their advanced expertise in the utilization of electronic sensors and data acquisition and analysis devices will be used to expand the use of such technology by teachers not only involved in research-based courses, but all areas of science education throughout the school district.

  17. Lake sediments provide the first eruptive history for Corbetti, a high-risk Main Ethiopian Rift volcano

    Science.gov (United States)

    Martin-Jones, Catherine M.; Lane, Christine S.; Pearce, Nicholas J. G.; Smith, Victoria C.; Lamb, Henry F.; Schaebitz, Frank; Viehberg, Finn; Brown, Maxwell C.; Frank, Ute; Asrat, Asfawossen

    2017-04-01

    A recent World Bank report found that 49 of Ethiopia's 65 known Holocene volcanoes pose a high-risk to the surrounding population. One of these volcanoes, Corbetti, located in the densely populated Main Ethiopian Rift (MER), has only one documented Holocene eruption. Any risk assessment for Corbetti is therefore highly uncertain. Reliable hazard forecasting is dependent on the completeness of volcanic records. In the case of Ethiopian Rift volcanoes complete records are hindered by frequently poorly exposed, buried and inaccessible proximal outcrops. Lake sediments can yield comprehensive, stratigraphically-resolved dossiers of past volcanism. Here we use volcanic ash (tephra) layers preserved in sediments from three MER lakes to provide the first record of Holocene volcanism for Corbetti. It shows that Corbetti has erupted explosively throughout the Holocene at an average return period of 800 years. Based on the thickness and dispersal of the tephras, at least six eruptions were of a large magnitude, and there were four eruptions in the past 2000 years. Future explosive eruptions are likely and these could have significant societal impacts, they could blanket nearby Awassa and Shashamene, home to 260,000 people, with pumice deposits. Our data indicate that the threat posed by Corbetti has been significantly underestimated. These data can be used to refine regional volcano monitoring and develop evacuation plans. This lake sediment-tephrostratigraphic approach shows significant potential for application throughout the East African Rift system, and is essential to understanding volcanic hazards in this rapidly developing region.

  18. High School Students' Accuracy in Estimating the Cost of College: A Proposed Methodological Approach and Differences among Racial/Ethnic Groups and College Financial-Related Factors

    Science.gov (United States)

    Nienhusser, H. Kenny; Oshio, Toko

    2017-01-01

    High school students' accuracy in estimating the cost of college (AECC) was examined by utilizing a new methodological approach, the absolute-deviation-continuous construct. This study used the High School Longitudinal Study of 2009 (HSLS:09) data and examined 10,530 11th grade students in order to measure their AECC for 4-year public and private…

  19. Organisational and environmental characteristics of residential aged care units providing highly person-centred care: a cross sectional study.

    Science.gov (United States)

    Sjögren, Karin; Lindkvist, Marie; Sandman, Per-Olof; Zingmark, Karin; Edvardsson, David

    2017-01-01

    Few studies have empirically investigated factors that define residential aged care units that are perceived as being highly person-centred. The purpose of this study was to explore factors characterising residential aged care units perceived as being highly person-centred, with a focus on organisational and environmental variables, as well as residents' and staff' characteristics. A cross-sectional design was used. Residents (n = 1460) and staff (n = 1213) data from 151 residential care units were collected, as well as data relating to characteristics of the organisation and environment, and data measuring degree of person-centred care. Participating staff provided self-reported data and conducted proxy ratings on residents. Descriptive and comparative statistics, independent samples t-test, Chi2 test, Eta Squared and Phi coefficient were used to analyse data. Highly person-centred residential aged care units were characterized by having a shared philosophy of care, a satisfactory leadership, interdisciplinary collaboration and social support from colleagues and leaders, a dementia-friendly physical environment, staff having time to spend with residents, and a smaller unit size. Residential aged care units with higher levels of person-centred care had a higher proportion of staff with continuing education in dementia care, and a higher proportion of staff receiving regular supervision, compared to units with lower levels of person-centred care. It is important to target organisational and environmental factors, such as a shared philosophy of care, staff use of time, the physical environment, interdisciplinary support, and support from leaders and colleagues, to improve person-centred care in residential care units. Managers and leaders seeking to facilitate person-centred care in daily practice need to consider their own role in supporting, encouraging, and supervising staff.

  20. Validation of an ultra-high-performance liquid chromatography-tandem mass spectrometry method to quantify illicit drug and pharmaceutical residues in wastewater using accuracy profile approach.

    Science.gov (United States)

    Hubert, Cécile; Roosen, Martin; Levi, Yves; Karolak, Sara

    2017-06-02

    The analysis of biomarkers in wastewater has become a common approach to assess community behavior. This method is an interesting way to estimate illicit drug consumption in a given population: by using a back calculation method, it is therefore possible to quantify the amount of a specific drug used in a community and to assess the consumption variation at different times and locations. Such a method needs reliable analytical data since the determination of a concentration in the ngL-1 range in a complex matrix is difficult and not easily reproducible. The best analytical method is liquid chromatography - mass spectrometry coupling after solid-phase extraction or on-line pre-concentration. Quality criteria are not specially defined for this kind of determination. In this context, it was decided to develop an UHPLC-MS/MS method to analyze 10 illicit drugs and pharmaceuticals in wastewater treatment plant influent or effluent using a pre-concentration on-line system. A validation process was then carried out using the accuracy profile concept as an innovative tool to estimate the probability of getting prospective results within specified acceptance limits. Influent and effluent samples were spiked with known amounts of the 10 compounds and analyzed three times a day for three days in order to estimate intra-day and inter-day variations. The matrix effect was estimated for each compound. The developed method can provide at least 80% of results within ±25% limits except for compounds that are degraded in influent. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Obstetric care providers are able to assess psychosocial risks, identify and refer high-risk pregnant women: validation of a short assessment tool - the KINDEX Greek version.

    Science.gov (United States)

    Spyridou, Andria; Schauer, Maggie; Ruf-Leuschner, Martina

    2015-02-21

    Prenatal assessment for psychosocial risk factors and prevention and intervention is scarce and, in most cases, nonexistent in obstetrical care. In this study we aimed to evaluate if the KINDEX, a short instrument developed in Germany, is a useful tool in the hands of non-trained medical staff, in order to identify and refer women in psychosocial risk to the adequate mental health and social services. We also examined the criterion-related concurrent validity of the tool through a validation interview carried out by an expert clinical psychologist. Our final objective was to achieve the cultural adaptation of the KINDEX Greek Version and to offer a valid tool for the psychosocial risk assessment to the obstetric care providers. Two obstetricians and five midwives carried out 93 KINDEX interviews (duration 20 minutes) with pregnant women to assess psychosocial risk factors present during pregnancy. Afterwards they referred women who they identified having two or more psychosocial risk factors to the mental health attention unit of the hospital. During the validation procedure an expert clinical psychologist carried out diagnostic interviews with a randomized subsample of 50 pregnant women based on established diagnostic instruments for stress and psychopathology, like the PSS-14, ESI, PDS, HSCL-25. Significant correlations between the results obtained through the assessment using the KINDEX and the risk areas of stress, psychopathology and trauma load assessed in the validation interview demonstrate the criterion-related concurrent validity of the KINDEX. The referral accuracy of the medical staff is confirmed through comparisons between pregnant women who have and have not been referred to the mental health attention unit. Prenatal screenings for psychosocial risks like the KINDEX are feasible in public health settings in Greece. In addition, validity was confirmed in high correlations between the KINDEX results and the results of the validation interviews. The

  2. The accuracy of the crystal chemical parameters at high-pressure conditions from single-crystal X-ray diffraction in diamond-anvil cell

    DEFF Research Database (Denmark)

    Periotto, Benedetta

    applications also in the materials science as it can provide useful information about the properties and performance of new materials. Over the past decades, the research in this field has been strongly developed due to the advances in computer capabilities and to the technological improvements of X-ray...... instruments. At the same time, the high-pressure experiments have benefited by the strong improvements on the high-pressure devices, in particular the diamond-anvil cell (DAC). The aim of this research project is to assess the quality of the data obtained by means of the single-crystal X-ray diffraction...... technique through the study of different mineral phases. The procedure for setting up an experiment under high-pressure conditions, using a single crystal as sample held within a DAC, are presented here with all the details of the in situ measurements at high-pressure conditions. The research project...

  3. Dynamic time warping assessment of high-resolution melt curves provides a robust metric for fungal identification

    Science.gov (United States)

    Phatak, Sayali S.; Li, Dongmei; Luka, Janos; Calderone, Richard A.

    2017-01-01

    Fungal infections are a global problem imposing considerable disease burden. One of the unmet needs in addressing these infections is rapid, sensitive diagnostics. A promising molecular diagnostic approach is high-resolution melt analysis (HRM). However, there has been little effort in leveraging HRM data for automated, objective identification of fungal species. The purpose of these studies was to assess the utility of distance methods developed for comparison of time series data to classify HRM curves as a means of fungal species identification. Dynamic time warping (DTW), first introduced in the context of speech recognition to identify temporal distortion of similar sounds, is an elastic distance measure that has been successfully applied to a wide range of time series data. Comparison of HRM curves of the rDNA internal transcribed spacer (ITS) region from 51 strains of 18 fungal species using DTW distances allowed accurate classification and clustering of all 51 strains. The utility of DTW distances for species identification was demonstrated by matching HRM curves from 243 previously identified clinical isolates against a database of curves from standard reference strains. The results revealed a number of prior misclassifications, discriminated species that are not resolved by routine phenotypic tests, and accurately identified all 243 test strains. In addition to DTW, several other distance functions, Edit Distance on Real sequence (EDR) and Shape-based Distance (SBD), showed promise. It is concluded that DTW-based distances provide a useful metric for the automated identification of fungi based on HRM curves of the ITS region and that this provides the foundation for a robust and automatable method applicable to the clinical setting. PMID:28264030

  4. First evidence of biogenic habitat from tubeworms providing a near-absolute habitat requirement for high-intertidal Ulva macroalgae.

    Directory of Open Access Journals (Sweden)

    Kiran Liversage

    Full Text Available Disturbances in ecological systems can cause new resources to become available and can free the resources held by strongly competitive species. In intertidal boulder fields, wave-action causes disturbance by overturning boulders and freeing space for re-colonisation. In this study, mensurative experiments showed that boulder disturbance may also cause new biogenic-habitat resources to become available, if pre-disturbance boulders originally had tubeworm encrustations on their undersides. On the high-shore of a South Australian rocky coast, a small proportion of boulders had extensive encrustations of serpulid and spirorbid worm-tubes on their uppersides, and were likely to have recently been overturned, as spirorbid tubeworms are almost always only underneath boulders while living. Ulva macroalgae was absent from all boulders, except those with worm-tubes, where up to 61% Ulva cover was observed. Many boulders with tubes did not, however, have much algae, and this was likely caused by grazing. While limpets were seldom observed attached to tube encrustations, snails such as Nerita atramentosa and Bembicium nanum were equally abundant on and off tubes. N. atramentosa was likely the main grazer, as its densities were negatively correlated with Ulva cover. The mechanism causing association of Ulva and worm-tubes is unknown, but may be related to retention of moisture or algal spores within the complex topography of the tubes. Alternatively, some tubes may still have been living and providing nutrients for Ulva from excretory products. This study takes the first step towards understanding a very distinct habitat requirement which allows an important alga to persist in the hostile environment of the rocky-intertidal high shore.

  5. First evidence of biogenic habitat from tubeworms providing a near-absolute habitat requirement for high-intertidal Ulva macroalgae.

    Science.gov (United States)

    Liversage, Kiran

    2017-01-01

    Disturbances in ecological systems can cause new resources to become available and can free the resources held by strongly competitive species. In intertidal boulder fields, wave-action causes disturbance by overturning boulders and freeing space for re-colonisation. In this study, mensurative experiments showed that boulder disturbance may also cause new biogenic-habitat resources to become available, if pre-disturbance boulders originally had tubeworm encrustations on their undersides. On the high-shore of a South Australian rocky coast, a small proportion of boulders had extensive encrustations of serpulid and spirorbid worm-tubes on their uppersides, and were likely to have recently been overturned, as spirorbid tubeworms are almost always only underneath boulders while living. Ulva macroalgae was absent from all boulders, except those with worm-tubes, where up to 61% Ulva cover was observed. Many boulders with tubes did not, however, have much algae, and this was likely caused by grazing. While limpets were seldom observed attached to tube encrustations, snails such as Nerita atramentosa and Bembicium nanum were equally abundant on and off tubes. N. atramentosa was likely the main grazer, as its densities were negatively correlated with Ulva cover. The mechanism causing association of Ulva and worm-tubes is unknown, but may be related to retention of moisture or algal spores within the complex topography of the tubes. Alternatively, some tubes may still have been living and providing nutrients for Ulva from excretory products. This study takes the first step towards understanding a very distinct habitat requirement which allows an important alga to persist in the hostile environment of the rocky-intertidal high shore.

  6. Predator diversity and abundance provide little support for the enemies hypothesis in forests of high tree diversity.

    Directory of Open Access Journals (Sweden)

    Andreas Schuldt

    Full Text Available Predatory arthropods can exert strong top-down control on ecosystem functions. However, despite extensive theory and experimental manipulations of predator diversity, our knowledge about relationships between plant and predator diversity--and thus information on the relevance of experimental findings--for species-rich, natural ecosystems is limited. We studied activity abundance and species richness of epigeic spiders in a highly diverse forest ecosystem in subtropical China across 27 forest stands which formed a gradient in tree diversity of 25-69 species per plot. The enemies hypothesis predicts higher predator abundance and diversity, and concomitantly more effective top-down control of food webs, with increasing plant diversity. However, in our study, activity abundance and observed species richness of spiders decreased with increasing tree species richness. There was only a weak, non-significant relationship with tree richness when spider richness was rarefied, i.e. corrected for different total abundances of spiders. Only foraging guild richness (i.e. the diversity of hunting modes of spiders was positively related to tree species richness. Plant species richness in the herb layer had no significant effects on spiders. Our results thus provide little support for the enemies hypothesis--derived from studies in less diverse ecosystems--of a positive relationship between predator and plant diversity. Our findings for an important group of generalist predators question whether stronger top-down control of food webs can be expected in the more plant diverse stands of our forest ecosystem. Biotic interactions could play important roles in mediating the observed relationships between spider and plant diversity, but further testing is required for a more detailed mechanistic understanding. Our findings have implications for evaluating the way in which theoretical predictions and experimental findings of functional predator effects apply to species

  7. Predator Diversity and Abundance Provide Little Support for the Enemies Hypothesis in Forests of High Tree Diversity

    Science.gov (United States)

    Schuldt, Andreas; Both, Sabine; Bruelheide, Helge; Härdtle, Werner; Schmid, Bernhard; Zhou, Hongzhang; Assmann, Thorsten

    2011-01-01

    Predatory arthropods can exert strong top-down control on ecosystem functions. However, despite extensive theory and experimental manipulations of predator diversity, our knowledge about relationships between plant and predator diversity—and thus information on the relevance of experimental findings—for species-rich, natural ecosystems is limited. We studied activity abundance and species richness of epigeic spiders in a highly diverse forest ecosystem in subtropical China across 27 forest stands which formed a gradient in tree diversity of 25–69 species per plot. The enemies hypothesis predicts higher predator abundance and diversity, and concomitantly more effective top-down control of food webs, with increasing plant diversity. However, in our study, activity abundance and observed species richness of spiders decreased with increasing tree species richness. There was only a weak, non-significant relationship with tree richness when spider richness was rarefied, i.e. corrected for different total abundances of spiders. Only foraging guild richness (i.e. the diversity of hunting modes) of spiders was positively related to tree species richness. Plant species richness in the herb layer had no significant effects on spiders. Our results thus provide little support for the enemies hypothesis—derived from studies in less diverse ecosystems—of a positive relationship between predator and plant diversity. Our findings for an important group of generalist predators question whether stronger top-down control of food webs can be expected in the more plant diverse stands of our forest ecosystem. Biotic interactions could play important roles in mediating the observed relationships between spider and plant diversity, but further testing is required for a more detailed mechanistic understanding. Our findings have implications for evaluating the way in which theoretical predictions and experimental findings of functional predator effects apply to species-rich forest

  8. A comprehensive evaluation of the accuracy of cervical pre-cancer detection methods in a high-risk area in East Congo

    Science.gov (United States)

    Hovland, S; Arbyn, M; Lie, A K; Ryd, W; Borge, B; Berle, E J; Skomedal, H; Kadima, T M; Kyembwa, L; Billay, E M; Mukwege, D; Chirimwami, R B; Mvula, T M; Snijders, P J; Meijer, C J L M; Karlsen, F

    2010-01-01

    Background: Given the high burden of cervical cancer in low-income settings, there is a need for a convenient and affordable method for detecting and treating pre-cancerous lesions. Methods: Samples for comparing the accuracy of cytology, virology and histology were collected. Identification of HPV E6/E7 mRNA was performed using PreTect HPV-Proofer. HPV DNA detection was performed by GP5+/6+ PCR, followed by reverse line blot (RLB) for typing. Results: A total of 343 women, aged 25–60 years, attending gynaecological polyclinics in DR Congo were included for sample enrolment. The test positivity rate was conventional and liquid-based cytology (LBC) at cutoff ASCUS+ of 6.9 and 6.6%, respectively; PreTect HPV-Proofer of 7.3% and consensus DNA PCR for 14 HR types of 18.5%. Sixteen cases of CIN2+ lesions were identified. Of these, conventional cytology identified 66.7% with a specificity of 96.2%, LBC identified 73.3% with a specificity of 96.9%, all at cutoff ASCUS+. HR-HPV DNA detected all CIN2+ cases with a specificity of 85.9%, whereas PreTect HPV-Proofer gave a sensitivity of 81.3% and a specificity of 96.6%. Conclusion: Both HPV detection assays showed a higher sensitivity for CIN2+ than did cytological methods. Detecting E6/E7 mRNA from only a subset of HR HPVs, as is the case with PreTect HPV-Proofer, resulted in a similar specificity to cytology and a significantly higher specificity than consensus HR HPV DNA (P<0.0001). PMID:20197765

  9. High Dose MicroCT Does Not Contribute Toward Improved MicroPET/CT Image Quantitative Accuracy and Can Limit Longitudinal Scanning of Small Animals

    Directory of Open Access Journals (Sweden)

    Wendy A. McDougald

    2017-10-01

    Full Text Available Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1 to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2 to evaluate the absorbed dose associated with varying CT parameters.Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA software implemented by Mediso. Measured Hounsfield Unit (HU in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC, uniformity and quantitative bias were also measured.Results: Only less than 2 and 1% of CT acquisition protocols yielded water HU values < −80 and air HU values < −840, respectively. Four out of 11 CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration.Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed toward improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  10. Accuracy of third-order bends of nickel-titanium wires and the effect of high and low pressure during memorizing heat treatment.

    Science.gov (United States)

    Stamm, Thomas; Hohoff, Ariane; Wiechmann, Dirk; Sütfeld, Jan; Helm, Dirk

    2004-10-01

    This study evaluated the accuracy of third-order bends of nickel-titanium wires and determined the effect of high and low pressure for maintaining the wire shape during memorizing heat treatment. A computer-aided bending machine was used to incorporate 200 randomly determined torsional angles between 0 degrees and 60 degrees into 30 linear 0.016 x 0.022-in NeoSentalloy F80 (GAC International, Central Islip, NY) wires. The torsional bendings were randomized into 2 groups. Bends assigned to group 1 (n = 100) received heat treatment of 1.6 MPa (16 bar) pressure, and bends assigned to group 2 (n = 100) received heat treatment of 50 MPa (500 bar) pressure. Cross-sectional cuts from the bent wires were prepared by using standard metallurgical techniques, and the torsional angles were analyzed under computer control. The results of our study show that third-order bends 30 degrees but 40 degrees , the bending error with both methods is clinically unacceptable. In addition to the variability in the dimension and composition of nickel-titanium wires, the scale of the incorporated plastic deformations makes a substantial contribution to the bending error. As far as permitted by the clinical situation, then, the bend should be distributed over the maximum possible wire length. Third-order bends in the first rectangular pseudoelastic nickel-titanium wires represent an efficient means of effecting torque at an early stage. This individualization allows the full therapeutic potential of these archwires to be exploited right from the initial phase of treatment.

  11. The views and attitudes of health professionals providing antenatal care to women with a high BMI: a qualitative research study.

    Science.gov (United States)

    Knight-Agarwal, Catherine Ruth; Kaur, Manmeet; Williams, Lauren T; Davey, Rachel; Davis, Deborah

    2014-06-01

    The prevalence of overweight and obesity is increasing amongst women of child bearing age. The objective of this study was to investigate the views and attitudes of providers of antenatal care for women who have a body mass index (BMI) of 30 kg/m(2) and over. A qualitative study using focus groups was undertaken within the department of obstetrics and gynaecology at a large teaching hospital in south-eastern Australia. Three focus group discussions were held. One with hospital midwives (n=10), one with continuity of care midwives (n=18) and one with obstetricians (n=5). Data were analysed using Interpretative Phenomenological Analysis (IPA). Six dominant themes emerged: (1) obesity puts the health of mothers, babies and health professionals at risk; (2) overweight and obesity has become the norm; (3) weighing women and advising about weight gain is out of fashion; (4) weight is a sensitive topic to discuss; (5) there are significant barriers to weight control in pregnancy; and (6) health professionals and women need to deal with maternal obesity. These themes are drawn together to form a model representing current health care issues for these women. Health professionals, who have a high BMI, can find it difficult to discuss obesity during antenatal visits with obese women. Specialist dietary interventions and evidence based guidelines for working with child-bearing women is seen as a public health priority by health care professionals. Copyright © 2013. Published by Elsevier Ltd.

  12. Drone with thermal infrared camera provides high resolution georeferenced imagery of the Waikite geothermal area, New Zealand

    Science.gov (United States)

    Harvey, M. C.; Rowland, J. V.; Luketina, K. M.

    2016-10-01

    Drones are now routinely used for collecting aerial imagery and creating digital elevation models (DEM). Lightweight thermal sensors provide another payload option for generation of very high-resolution aerial thermal orthophotos. This technology allows for the rapid and safe survey of thermal areas, often present in inaccessible or dangerous terrain. Here we present a 2.2 km2 georeferenced, temperature-calibrated thermal orthophoto of the Waikite geothermal area, New Zealand. The image represents a mosaic of nearly 6000 thermal images captured by drone over a period of about 2 weeks. This is thought by the authors to be the first such image published of a significant geothermal area produced by a drone equipped with a thermal camera. Temperature calibration of the image allowed calculation of heat loss (43 ± 12 MW) from thermal lakes and streams in the survey area (loss from evaporation, conduction and radiation). An RGB (visible spectrum) orthomosaic photo and digital elevation model was also produced for this area, with ground resolution and horizontal position error comparable to commercially produced LiDAR and aerial imagery obtained from crewed aircraft. Our results show that thermal imagery collected by drones has the potential to become a key tool in geothermal science, including geological, geochemical and geophysical surveys, environmental baseline and monitoring studies, geotechnical studies and civil works.

  13. Target Price Accuracy

    Directory of Open Access Journals (Sweden)

    Alexander G. Kerl

    2011-04-01

    Full Text Available This study analyzes the accuracy of forecasted target prices within analysts’ reports. We compute a measure for target price forecast accuracy that evaluates the ability of analysts to exactly forecast the ex-ante (unknown 12-month stock price. Furthermore, we determine factors that explain this accuracy. Target price accuracy is negatively related to analyst-specific optimism and stock-specific risk (measured by volatility and price-to-book ratio. However, target price accuracy is positively related to the level of detail of each report, company size and the reputation of the investment bank. The potential conflicts of interests between an analyst and a covered company do not bias forecast accuracy.

  14. Improving Speaking Accuracy through Awareness

    Science.gov (United States)

    Dormer, Jan Edwards

    2013-01-01

    Increased English learner accuracy can be achieved by leading students through six stages of awareness. The first three awareness stages build up students' motivation to improve, and the second three provide learners with crucial input for change. The final result is "sustained language awareness," resulting in ongoing…

  15. Rethinking Empathic Accuracy

    OpenAIRE

    Meadors, Joshua

    2014-01-01

    The present study is a methodological examination of the implicit empathic accuracy measure introduced by Zaki, Ochsner, and Bolger (2008). Empathic accuracy (EA) is defined as the ability to understand another person's thoughts and feelings (Ickes, 1993). Because this definition is similar to definitions of cognitive empathy (e.g., Shamay-Tsoory, 2011) and because affective empathy does not appear to be related to empathic accuracy (Zaki et al., 2008), the Basic Empathy Scale--which measures...

  16. High-energy photon activation tandem mass spectrometry provides unprecedented insights into the structure of highly sulfated oligosaccharides extracted from macroalgal cell walls.

    Science.gov (United States)

    Ropartz, David; Giuliani, Alexandre; Hervé, Cécile; Geairon, Audrey; Jam, Murielle; Czjzek, Mirjam; Rogniaux, Hélène

    2015-01-20

    Extreme ultraviolet photon activation tandem mass spectrometry (MS) at 69 nm (18 eV) was used to characterize mixtures of oligo-porphyrans, a class of highly sulfated oligosaccharides. Porphyrans, hybrid polymers whose structures are far from known, continue to provide a challenge for analytical method development. Activation by 18 eV photons led to a rich fragmentation of the oligo-porphyrans, with many cross-ring and glycosidic cleavages. In contrast to multistage MSn strategies such as activated electron photodetachment dissociation, a single step of irradiation by energetic UV of multiply charged anions led to a complete fragmentation of the oligo-porphyrans. In both ionization modes, the sulfate groups were retained on the backbone, which allowed the pattern of these modifications along the porphyran backbone to be described in unprecedented detail. Many structures released by the enzymatic degradation of the porphyran were completely resolved, including isomers. This work extends the existing knowledge of the structure of porphyrans. In addition, it provides a new demonstration of the potential of activation by high-energy photons for the structural analysis of oligosaccharides, even in unseparated mixtures, with a particular focus on sulfated compounds.

  17. Diagnostic accuracy of fine needle aspiration cytology in providing a ...

    African Journals Online (AJOL)

    http://dx.doi.org/10.4314/ahs.v15i1.15 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact AJOL · News. OTHER RESOURCES... for Researchers · for Journals · for Authors · for Policy Makers ...

  18. Screening halogenated environmental contaminants in biota based on isotopic pattern and mass defect provided by high resolution mass spectrometry profiling

    Energy Technology Data Exchange (ETDEWEB)

    Cariou, Ronan, E-mail: laberca@oniris-nantes.fr; Omer, Elsa; Léon, Alexis; Dervilly-Pinel, Gaud; Le Bizec, Bruno

    2016-09-14

    In the present work, we addressed the question of global seeking/screening organohalogenated compounds in a large panel of complex biological matrices, with a particular focus on unknown chemicals that may be considered as potential emerging hazards. A fishing strategy was developed based on untargeted profiling among full scan acquisition datasets provided by high resolution mass spectrometry. Since large datasets arise from such profiling, filtering useful information stands as a central question. In this way, we took advantage of the exact mass differences between Cl and Br isotopes. Indeed, our workflow involved an innovative Visual Basic for Applications script aiming at pairing features according to this mass difference, in order to point out potential organohalogenated clusters, preceded by an automated peak picking step based on the centWave function (xcms package of open access R programming environment). Then, H/Cl-scale mass defect plots were used to visualize the datasets before and after filtering. The filtering script was successfully applied to a dataset generated upon liquid chromatography coupled to ESI(−)-HRMS measurement from one eel muscle extract, allowing for realistic manual investigations of filtered clusters. Starting from 9789 initial obtained features, 1994 features were paired in 589 clusters. Hexabromocyclododecane, chlorinated paraffin series and various other compounds have been identified or tentatively identified, allowing thus broad screening of organohalogenated compounds in this extract. Although realistic, manual review of paired clusters remains time consuming and much effort should be devoted to automation. - Highlights: • We address the screening of halogenated compounds in large Full Scan HRMS datasets. • The workflow involv