WorldWideScience

Sample records for proton irradiated float-zone

  1. Simultaneous electron-proton irradiation of crucible grown and float-zone silicon solar cells

    International Nuclear Information System (INIS)

    Bernard, J.

    1974-01-01

    The realisation of an irradiation chamber which permits simultaneous irradiations by electrons, protons, photons and in-situ measurements of solar cells main parameters (diffusion length, I.V. characteristics) is described. Results obtained on 20 solar cells n/p 10Ωcm made in silicon pulled crystals and 20 solar cells n/p 10Ωcm made in silicon float-zone simultaneously irradiated with electrons and photons are given [fr

  2. Proton irradiation effects in silicon devices

    Energy Technology Data Exchange (ETDEWEB)

    Simoen, E; Vanhellemont, J; Alaerts, A [IMEC, Leuven (Belgium); and others

    1997-03-01

    Proton irradiation effects in silicon devices are studied for components fabricated in various substrates in order to reveal possible hardening effects. The degradation of p-n junction diodes increases in first order proportionally with the fluence, when submitted to 10 MeV proton irradiations in the range 5x10{sup 9} cm{sup -2} to 5x10{sup 11} cm{sup -2}. The damage coefficients for both p- and n-type Czochralski, Float-Zone and epitaxial wafers are reported. Charge-Coupled Devices fabricated in a 1.2 {mu}m CCD-CMOS technology are shown to be quite resistant to 59 MeV H{sup +} irradiations, irrespective of the substrate type. (author)

  3. Field ion microscopy study of depleted zones in tungsten after proton irradiation

    International Nuclear Information System (INIS)

    Farnum, D.J.; Sommer, W.F.; Inal, O.T.; Yu, J.

    1986-01-01

    Depleted zones in tungsten, that resulted from medium-energy proton irradiations, were studied using the Field Ion Microscope (FIM). The shapes and sizes of depleted zones is an important aspect of basic radiation damage. These data can be compared to models that have been suggested as well as aid development of new models. These depleted volumes are of interest not only for an understanding of basic radiation effects, but also because they affect material properties and can act as nucleation sites for voids or gas bubbles. Depleted zones were produced in annealed tungsten wires by irradiation with 600 to 800 MeV protons at the Los Alamos Meson Physics Facility. The defects observed in the irradiated samples included vacancies, depleted zones, grain boundaries, and dislocations. Single vacancies were the most commonly observed defect. Of the samples ''imaged,'' over 50 depleted zones were found within the area of high resolution in the area between the prominent [112] poles in a [110] oriented sample. The number of layers photographed in each sample was dependent upon the initial shape of the tip and ranged from 60 to 200 [110] sequential layers

  4. An annealing study of charge collection efficiency on Float-Zone p-on-n ministrip sensors irradiated with 24 GeV/c protons and 20 MeV neutrons

    International Nuclear Information System (INIS)

    Pacifico, N.; Dolenc-Kittelmann, I.; Gabrysch, M.; Moll, M.; Lucas, C.

    2015-01-01

    Float-Zone n-bulk p-readout silicon sensors are currently operated in the tracking layers of many High Energy Physics experiments, where they are exposed to moderate to high fluences of hadrons. Though n-readout sensors, either with p or n bulk, are available and are offering an improved radiation hardness, p-on-n sensors are still widely used and are e.g. installed in the present ATLAS and CMS experiments at CERN. Their radiation hardness and long-term performance are therefore of high interest to the detector community. We present here a study performed on these sensors after irradiation with 24 GeV/c protons and 20 MeV neutrons to fluences ranging from 1⋅10 14 to 1⋅10 15 n eq /cm 2 . The sensors were then investigated for charge collection efficiency after different isothermal annealing steps in order to understand the performance evolution of the sensor with annealing time. Additional measurements were performed for the highest neutron fluence by means of the Edge-TCT technique, to assess the electric field configuration within the sensor. The irradiation and the annealing scenarios were chosen to represent the radiation damage scenario over the expected lifetime of the LHC detectors (and even further) and to assess the effect of unplanned annealing due to potentially longer warm shutdowns or cooling problems

  5. Surface cracking in proton-irradiated glass

    International Nuclear Information System (INIS)

    Jensen, T.; Lawn, B.R.; Dalglish, R.L.; Kelly, J.C.

    1976-01-01

    Some observations are reported of the surface fracture behaviour of soda-lime glass slabs (6mm thick Pilkington float glass) irradiated with 480 kV protons. A simple indentation microfracture technique provided a convenient means of probing the irradiated surface regions. Basically, the technique involves loading a standard Vickers diamond pyramid indenter onto the area of interest such that a well-developed deformation/fracture pattern is generated. (author)

  6. Electrical properties of as-grown and proton-irradiated high purity silicon

    Energy Technology Data Exchange (ETDEWEB)

    Krupka, Jerzy, E-mail: krupka@imio.pw.edu.pl [Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw (Poland); Karcz, Waldemar [Joint Institute for Nuclear Research, Joliot-Curie 6, 141980 Dubna (Russian Federation); Kamiński, Paweł [Institute of Electronic Materials Technology, Wólczyńska 13, 301-919 Warsaw (Poland); Jensen, Leif [Topsil Semiconductor Materials A/S, Siliciumvej 1, DK-3600 Frederikssund (Denmark)

    2016-08-01

    The complex permittivity of as-grown and proton-irradiated samples of high purity silicon obtained by the floating zone method was measured as a function of temperature at a few frequencies in microwave spectrum by employing the quasi TE{sub 011} and whispering gallery modes excited in the samples under test. The resistivity of the samples was determined from the measured imaginary part of the permittivity. The resistivity was additionally measured at RF frequencies employing capacitive spectroscopy as well as in a standard direct current experiment. The sample of as-grown material had the resistivity of ∼85 kΩ cm at room temperature. The sample irradiated with 23-MeV protons had the resistivity of ∼500 kΩ cm at 295 K and its behavior was typical of the intrinsic material at room and at elevated temperatures. For the irradiated sample, the extrinsic conductivity region is missing and at temperatures below 250 K hopping conductivity occurs. Thermal cycle hysteresis of the resistivity for the sample of as-grown material is observed. After heating and subsequent cooling of the sample, its resistivity decreases and then slowly (∼50 h) returns to the initial value.

  7. Positron probing of open vacancy volume of phosphorus-vacancy complexes in float-zone n-type silicon irradiated by 0.9-MeV electrons and by 15-MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Arutyunov, Nikolay [Department of Physics, Martin Luther University Halle (Germany); Ioffe Physico-Technical Institute, St. Petersburg (Russian Federation); Institute of Ion-Plasma and Laser Technologies (Institute of Electronics), Tashkent (Uzbekistan); Emtsev, Vadim; Oganesyan, Gagik [Ioffe Physico-Technical Institute, St. Petersburg (Russian Federation); Elsayed, Mohamed [Department of Physics, Martin Luther University Halle (Germany); Faculty of Science, Department of Physics, Minia University (Egypt); Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle (Germany); Abrosimov, Nikolay [Leibniz Institute for Crystal Growth, Berlin (Germany); Kozlovski, Vitalii [St. Petersburg State Polytechnical University (Russian Federation)

    2017-07-15

    For the first time the samples, cut from the same wafer of crystals of float-zone silicon, n-FZ-Si(P) and n-FZ-Si(Bi), were subjected to irradiation with 0.9-MeV electrons and 15-MeV protons at RT for studying them by low-temperature positron annihilation lifetime spectroscopy. Measurements of Hall effect have been used for the materials characterization. The discussion is focused on the open vacancy volume (V{sub op}) of the thermally stable group-V-impurity-vacancy complexes comprising the phosphorus atoms; the bismuth-related vacancy complexes are briefly considered. The data of positron probing of PV pairs (E-centers), divacancies, and the thermally stable defects in the irradiated n-FZ-Si(P) materials are compared. Beyond a reliable detecting of the defect-related positron annihilation lifetime in the course of isochronal annealing at ∝ 500 C, the recovery of concentration of phosphorus-related shallow donor states continues up to ∝650-700 C. The open vacancy volumes V{sub op} to be characterized by long positron lifetimes Δτ{sub 2} ∝271-289 ps in (gr.-V-atom)-V{sub op} complexes are compared with theoretical data available for the vacancies, τ(V{sub 1}), and divacancies, τ(V{sub 2}). The extended semi-vacancies, 2V{sub s-ext}, and relaxed vacancies, 2V{sub inw}, are proposed as the open volume V{sub op} in (gr.-V-atom)-V{sub op} complexes. It is argued that at high annealing temperature the defect P{sub s}-V{sub op}-P{sub s} is decomposed. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Hall effect measurements on proton-irradiated ROSE samples

    International Nuclear Information System (INIS)

    Biggeri, U.; Bruzzi, M.; Borchi, E.

    1997-01-01

    Bulk samples obtained from two wafers of a silicon monocrystal material produced by Float-Zone refinement have been analyzed using the four-point probe method. One of the wafers comes from an oxygenated ingot; two sets of pure and oxygenated samples have been irradiated with 24 GeV/c protons in the fluence range from 10 13 p/cm 2 to 2x10 14 p/cm 2 . Van der Pauw resistivity and Hall coefficient have been measured before and after irradiation as a function of the temperature. A thermal treatment (30 minutes at 100C) has been performed to accelerate the reverse annealing effect in the irradiated silicon. The irradiated samples show the same exponential dependence of the resistivity and of the Hall coefficient on the temperature from 370K to 100K, corresponding to the presence of radiation-induced deep energy levels around 0.6-0.7eV in the silicon gap. The free carrier concentrations (n, p) have been evaluated in the investigated fluence range. The inversion of the conductivity type from n to p occurred respectively at 7x10 13 p/cm 2 and at 4x10 13 p/cm 2 before and after the annealing treatment, for both the two sets. Only slight differences have been detected between the pure and oxygenated samples

  9. 33 CFR 147.847 - Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone.

    Science.gov (United States)

    2010-07-01

    ... Production, Storage, and Offloading System Safety Zone. 147.847 Section 147.847 Navigation and Navigable... ZONES § 147.847 Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone. (a) Description. The BW PIONEER, a Floating Production, Storage and Offloading (FPSO) system, is in...

  10. Proton production, neutralisation and reduction in a floating water bridge

    International Nuclear Information System (INIS)

    Sammer, Martina; Wexler, Adam D; Kuntke, Philipp; Stanulewicz, Natalia; Lankmayr, Ernst; Woisetschläger, Jakob; Fuchs, Elmar C; Wiltsche, Helmar

    2015-01-01

    This work reports on proton production, transport, reduction and neutralization in floating aqueous bridges under the application of a high dc voltage (‘floating water bridge’). Recently possible mechanisms for proton transfer through the bridge were suggested. In this work we visualize and describe the production of protons in the anolyte and their neutralization in the catholyte. Apart from that, protons are reduced to hydrogen due to electrolysis. Microbubbles are detached instantly, due to the electrohydrodynamic flow at the electrode surface. No larger, visible bubbles are formed and the system degasses through the bridge due to its higher local temperature. A detailed analysis of trace elements originating from beaker material, anode or the atmosphere is presented, showing that their influence on the overall conduction compared to the contribution of protons is negligible. Finally, an electrochemical rationale of high voltage electrolysis of low ionic strength solutions is presented. (paper)

  11. Proton production, neutralisation and reduction in a floating water bridge

    Science.gov (United States)

    Sammer, Martina; Wexler, Adam D.; Kuntke, Philipp; Wiltsche, Helmar; Stanulewicz, Natalia; Lankmayr, Ernst; Woisetschläger, Jakob; Fuchs, Elmar C.

    2015-10-01

    This work reports on proton production, transport, reduction and neutralization in floating aqueous bridges under the application of a high dc voltage (‘floating water bridge’). Recently possible mechanisms for proton transfer through the bridge were suggested. In this work we visualize and describe the production of protons in the anolyte and their neutralization in the catholyte. Apart from that, protons are reduced to hydrogen due to electrolysis. Microbubbles are detached instantly, due to the electrohydrodynamic flow at the electrode surface. No larger, visible bubbles are formed and the system degasses through the bridge due to its higher local temperature. A detailed analysis of trace elements originating from beaker material, anode or the atmosphere is presented, showing that their influence on the overall conduction compared to the contribution of protons is negligible. Finally, an electrochemical rationale of high voltage electrolysis of low ionic strength solutions is presented.

  12. Infrared defect dynamics—Nitrogen-vacancy complexes in float zone grown silicon introduced by electron irradiation

    Science.gov (United States)

    Inoue, Naohisa; Kawamura, Yuichi

    2018-05-01

    The interaction of nitrogen and intrinsic point defects, vacancy (V) and self-interstitial (I), was examined by infrared absorption spectroscopy on the electron irradiated and post-annealed nitrogen doped float zone (FZ) silicon crystal. Various absorption lines were observed, at 551 cm-1 in as-grown samples, at 726 and 778 cm-1 in as-irradiated samples (Ir group), at 689 cm-1 after post-annealing at 400 °C and above (400 °C group), at 762 and 951 cm-1 after annealing at 600 °C (600 °C group), and at 714 cm-1 up to 800 °C (800 °C group). By irradiation, a part of N2 was changed into the Ir group. VN2 is the candidate for the origin of the Ir group. By the post annealing at 400 and 600 °C, a part of N2 and the Ir group were changed into the 400 °C group, to less extent at 600 °C. V2N2 is the candidate for the origin of the 400 °C group. By annealing at 600 °C, most of the Ir group turned into 400 °C and 600 °C groups. By annealing at 800 °C, N2 recovered almost completely, and most other complexes were not observed. Recently, lifetime degradation has been observed in the nitrogen doped FZ Si annealed at between 450 and 800 °C. The N-V interaction in the same temperature range revealed here will help to understand the lifetime degradation mechanism. The behavior of the 689 cm-1 line corresponded well to the lifetime degradation.

  13. A comparison between rad-hard float zone silicon diodes as gamma dosimeter in radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Fábio de [Amazônia Azul Tecnologias de Defesa S.A. (AMAZUL), São Paulo, SP (Brazil); Gonçalves, Josemary A.C.; Bueno, Carmen C., E-mail: dcamargo@gmail.com, E-mail: ccbueno@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)

    2017-07-01

    In this work, we report on the results obtained with rad-hard Standard Float Zone (STFZ) and Diffused Oxygenated Float Zone (DOFZ) silicon diodes in radiation processing dosimetry. The dosimetric probes were designed to operate in the direct current mode, as on-line radiation dosimeter. The irradiation of the samples was performed using a {sup 60}Co source with a dose rate of almost 2.4 kGy/h. The current response of each diode was measured as a function of the exposure time in steps from 5 kGy up to 50 kGy to achieve a total absorbed dose of 275 kGy. In this dose range it is observed a significant decrease in the photocurrent generated in both devices due to gamma radiation defects produced in their active volumes. To mitigate this effect, the samples were pre-irradiated with {sup 60}Co gamma rays at 700 kGy. Despite of being less sensitive, these devices presented stable and reproducible current signals with a relative sensitivity decrease of about 19% within the whole range of dose studied. The dose-response curves of the pre-irradiated diodes showed quadratic behavior with correlation coefficient higher than 0.9999 for total absorbed dose up to 275 kGy. The comparison of the FZ and DOFZ responses evidenced that the latter was slightly superior to the first. However, it is important to note that all pre-irradiated diodes can be used as gamma dosimeters in radiation processing applications. (author)

  14. A comparison between rad-hard float zone silicon diodes as gamma dosimeter in radiation processing

    International Nuclear Information System (INIS)

    Camargo, Fábio de; Gonçalves, Josemary A.C.; Bueno, Carmen C.

    2017-01-01

    In this work, we report on the results obtained with rad-hard Standard Float Zone (STFZ) and Diffused Oxygenated Float Zone (DOFZ) silicon diodes in radiation processing dosimetry. The dosimetric probes were designed to operate in the direct current mode, as on-line radiation dosimeter. The irradiation of the samples was performed using a 60 Co source with a dose rate of almost 2.4 kGy/h. The current response of each diode was measured as a function of the exposure time in steps from 5 kGy up to 50 kGy to achieve a total absorbed dose of 275 kGy. In this dose range it is observed a significant decrease in the photocurrent generated in both devices due to gamma radiation defects produced in their active volumes. To mitigate this effect, the samples were pre-irradiated with 60 Co gamma rays at 700 kGy. Despite of being less sensitive, these devices presented stable and reproducible current signals with a relative sensitivity decrease of about 19% within the whole range of dose studied. The dose-response curves of the pre-irradiated diodes showed quadratic behavior with correlation coefficient higher than 0.9999 for total absorbed dose up to 275 kGy. The comparison of the FZ and DOFZ responses evidenced that the latter was slightly superior to the first. However, it is important to note that all pre-irradiated diodes can be used as gamma dosimeters in radiation processing applications. (author)

  15. TSC measurements on proton-irradiated p-type Si-sensors

    Energy Technology Data Exchange (ETDEWEB)

    Donegani, Elena; Fretwurst, Eckhart; Garutti, Erika; Junkes, Alexandra [University of Hamburg (Germany)

    2016-07-01

    Thin n{sup +}p Si sensors are potential candidates for coping with neutron equivalent fluences up to 2.10{sup 16} n{sub eq}/cm{sup 2} and an ionizing dose in the order of a few MGy, which are expected e.g. for the HL-LHC upgrade. The aim of the present work is to provide experimental data on radiation-induced defects in order to: firstly, get a deeper understanding of the properties of hadron induced defects, and secondly develop a radiation damage model based on microscopic measurements. Therefore, the outcomes of Thermally Stimulated Current measurements on 200 μm thick Float-Zone (FZ) and Magnetic Czochralski (MCz) diodes will be shown, as a results of irradiation with 23 MeV protons and isothermal annealing. The samples were irradiated in the fluence range (0.3-1).10{sup 14} n{sub eq}/cm{sup 2}, so that the maximal temperature at which the TSC signal is still sharply distinguishable from the dark current is 200 K. In particular, special focus will be given to the defect introduction rate and to the issue of boron removal in p-type silicon. Annealing studies allow to distinguish which defects mainly contribute to the leakage current and which to the space charge, and thus correlate microscopic defects properties with macroscopic sensor properties.

  16. Production and aging of paramagnetic point defects in P-doped floating zone silicon irradiated with high fluence 27 MeV electrons

    Science.gov (United States)

    Joita, A. C.; Nistor, S. V.

    2018-04-01

    Enhancing the long term stable performance of silicon detectors used for monitoring the position and flux of the particle beams in high energy physics experiments requires a better knowledge of the nature, stability, and transformation properties of the radiation defects created over the operation time. We report the results of an electron spin resonance investigation in the nature, transformation, and long term stability of the irradiation paramagnetic point defects (IPPDs) produced by high fluence (2 × 1016 cm-2), high energy (27 MeV) electrons in n-type, P-doped standard floating zone silicon. We found out that both freshly irradiated and aged (i.e., stored after irradiation for 3.5 years at 250 K) samples mainly contain negatively charged tetravacancy and pentavacancy defects in the first case and tetravacancy defects in the second one. The fact that such small cluster vacancy defects have not been observed by irradiation with low energy (below 5 MeV) electrons, but were abundantly produced by irradiation with neutrons, strongly suggests the presence of the same mechanism of direct formation of small vacancy clusters by irradiation with neutrons and high energy, high fluence electrons, in agreement with theoretical predictions. Differences in the nature and annealing properties of the IPPDs observed between the 27 MeV electrons freshly irradiated, and irradiated and aged samples were attributed to the presence of a high concentration of divacancies in the freshly irradiated samples, defects which transform during storage at 250 K through diffusion and recombination processes.

  17. Emulation of neutron irradiation effects with protons: validation of principle

    International Nuclear Information System (INIS)

    Was, G.S.; Busby, J.T.; Allen, T.; Kenik, E.A.; Jensson, A.; Bruemmer, S.M.; Gan, J.; Edwards, A.D.; Scott, P.M.; Andreson, P.L.

    2002-01-01

    denuded zones were only observed in neutron-irradiated samples. No cavities were observed for either irradiating particle. For both irradiating particles, hardening increased with dose for both heats, showing a more rapid increase and approach to saturation for heat B. In normal oxygenated water chemistry (NWC) at 288 deg. C, stress corrosion cracking in the 304 alloy was first observed at about 1.0 dpa and increased with dose. The 316 alloy was remarkably resistant to IASCC for both particle types. In hydrogen treated, de-oxygenated water (HWC), proton-irradiated samples of the 304 alloy exhibited IG cracking at 1.0 dpa compared to about 3.0 dpa for neutron-irradiated samples, although differences in specimen geometry, test condition and test duration can account for this difference. Cracking in heat P in HWC occurred at about 5.0 dpa for both irradiating particles. Thus, in all aspects of radiation effects, including grain boundary microchemistry, dislocation loop microstructure, radiation hardening and SCC behavior, proton-irradiation results were in good agreement with neutron-irradiation results, providing validation of the premise that the totality of neutron-irradiation effects can be emulated by proton irradiation of appropriate energy

  18. Chemical changes in PMMA as a function of depth due to proton beam irradiation

    International Nuclear Information System (INIS)

    Szilasi, S.Z.; Huszank, R.; Szikra, D.; Vaczi, T.; Rajta, I.; Nagy, I.

    2011-01-01

    Highlights: → Chemical changes were investigated as a function of depth in proton irradiated PMMA → The depth profile of numerous functional groups was determined along the depth → The degree of chemical modification strongly depends on the LET of protons → At low-fluences the zone of maximal modification is restricted to the Bragg peak → At higher fluences the zone of max. modification extends towards the sample surface. - Abstract: In this work we determined depth profiles of the chemical change in PMMA irradiated with 2 MeV protons by infrared spectroscopic and micro-Raman measurements. The measurements were carried out on 10 μm thin stacked foil samples using an infrared spectrometer in universal attenuated total reflectance (UATR) and transmission modes; while the thick samples were analyzed with a confocal micro-Raman spectrometer. The depth profiles of the changes formed due to the various delivered fluences were compared to each other. The measurements show the strong dependence of the degree of modification on the energy transfer from the decelerating protons. Depth profiles reveal that at the fluences applied in this work the entire irradiated volume suffered some chemical modifications. In case of low-fluence samples the zone of maximal modification is restricted only to the Bragg peak, but with increasing fluences the region of maximal modification extends towards the sample surface.

  19. Proton irradiation effects on organic polymers

    International Nuclear Information System (INIS)

    Seguchi, T.; Sasuga, T.; Kawakami, W.; Hagiwara, M.; Kohno, I.; Kamitsubo, H.

    1987-01-01

    Organic polymer films(100 μm thickness) of polyethylene, polypropylene, polyethyleneterephtalate, and polyethersulfone were irradiated by protons of 8 MeV using a cyclotron, and their radiation effects were investigated by the changes of mechanical properties. In order to irradiate protons uniformly over wide area of polymer films, specimens were scanned during proton irradiation using a special apparatus. The absorbed dose was measured by CTA and RCD film dosimeters, and can be determined that 1 μC/cm 2 of 8 MeV proton fluence is equivalent to 54 kGy. For polyethylene and polypropylene, there was no significant difference between proton and electron irradiation for same doses. However, for polyethersulfone the decay of mechanical property was observed to be less than that of irradiation by electron. (author)

  20. Positron probing of phosphorus-vacancy complexes in silicon irradiated with 15 MeV protons

    Science.gov (United States)

    Arutyunov, N.; Emtsev, V.; Krause-Rehberg, R.; Elsayed, M.; Kessler, C.; Kozlovski, V.; Oganesyan, G.

    2015-06-01

    Defects in phosphorus-doped silicon samples of floating-zone material, n-FZ-Si(P), produced under irradiation with 15 MeV protons at room temperature are studied by positron annihilation lifetime spectroscopy over the temperature range of ∼ 30 K - 300 K and by low- temperature Hall effect measurements. After annealing of E-centersand divacancies, we detected for the first time high concentrations of positron traps which had not been observed earlier. These defects are isochronally annealed over the temperature interval of ∼ 320 °C - 700 °C they manifest themselves as electrically neutral deep donor centersin the material of n-type. A long-lived component of the positron lifetime, τ2(I2 enthalpy and entropy of annealing of these centersare Ea ∼ 1.05(0.21) eV and ΔSm ≈ 3.1(0.6)kB, respectively. It is argued that the microstructure of the defect consists of two vacancies, VV, and one atom of phosphorus, P. The split configuration of the VPV complex is shortly discussed.

  1. The PIREX proton irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Victoria, M. [Association EURATOM, Villigen (Switzerland)

    1995-10-01

    The proton Irradiation Experiment (PIREX) is a materials irradiation facility installed in a beam line of the 590 MeV proton accelerator at the Paul Scherrer Institute. Its main purpose is the testing of candidate materials for fusion reactor components. Protons of this energy produce simultaneously displacement damage and spallation products, amongst them helium and can therefore simulate any possible synergistic effects of damage and helium, that would be produced by the fusion neutrons.

  2. The PIREX proton irradiation facility

    International Nuclear Information System (INIS)

    Victoria, M.

    1995-01-01

    The proton Irradiation Experiment (PIREX) is a materials irradiation facility installed in a beam line of the 590 MeV proton accelerator at the Paul Scherrer Institute. Its main purpose is the testing of candidate materials for fusion reactor components. Protons of this energy produce simultaneously displacement damage and spallation products, amongst them helium and can therefore simulate any possible synergistic effects of damage and helium, that would be produced by the fusion neutrons

  3. Studies of the sensitivity dependence of float zone silicon diodes on gamma absorbed dose

    International Nuclear Information System (INIS)

    Pascoalino, K.C.S.; Santos, T.C. dos; Barbosa, R.F.; Camargo, F. de; Goncalves, J.A.C.; Bueno, C.C.

    2011-01-01

    Full text: Several advantages of silicon diodes which include small size, low cost, high sensitivity and wide availability, make them suitable for dosimetry and for radiation field mapping. However, the small radiation tolerance of ordinary silicon devices has imposed constraints on their application in intense radiation fields such as found in industrial radiation processes. This scenario has been changed with the development of radiation hard silicon devices to be used as track detectors in high-energy physics experiments. Particularly, in this work it is presented the dosimetric results obtained with a batch of nine junction silicon diodes developed, in the framework of CERN RD50 Collaboration, as good candidates for improved radiation hardness. These diodes were produced with 300 micrometer n-type silicon substrate grown by standard float zone technique and processed by the Microelectronics Center of Helsinki University of Technology. The samples irradiation was performed using a Co-60 irradiator (Gammacell 220) which delivers a dose-rate of 2 kGy/h. During the irradiation, the unbiased diodes were connected through low-noise coaxial cables to the input of a KEITHLEY 617 electrometer, in order to monitor the devices photocurrent as a function of the exposure time. To study the response uniformity of the batch of nine diodes as well the sensitivity dependence on the absorbed dose, they were irradiated with different doses from 5 kGy up to 50 kGy. The sensitivity response of each device was investigated through the on-line measurements of the current signals as a function of the exposure time. For doses up to 5 kGy, all diodes exhibited a current decay of almost six percent in comparison with the value registered at the start-time of the irradiation. However, this decrease in the current sensitivity is much smaller than those observed with ordinary diodes for the same absorbed dose. The dose-response curves of the devices were also investigated through the plot

  4. Acute skin reactions observed in fractionated proton irradiation

    International Nuclear Information System (INIS)

    Arimoto, Takuro; Maruhashi, Noboru; Takada, Yoshihisa; Hayakawa, Yoshinori; Inada, Tetsuo; Kitagawa, Toshio

    1989-01-01

    Between May 1985 and July 1987, 49 skin reactions of 43 patients treated by proton irradiation were observed at the Particle Radiation Medical Science Center (PARMS), the University of Tsukuba. Taking the peak skin score as an endpoint, the radiobiological effects [relative biological effectiveness (RBE) and time-dose relationship] of the proton beam in multi-fractionated treatments were estimated. Factors influencing the skin dose, such as the prescribed tumor dose, tumor site, and number of applied fields, were also analyzed. The following conclusions regarding acute skin reactions to the clinical use of proton irradiation were obtained: 1) the physical skin-sparing effect of proton irradiation in single-field irradiation, especially in superficial regions, is not large compared with that of high-energy photon irradiation; 2) multidirectional proton irradiation significantly reduced the skin dose and severity of acute reasons; 3) the radiobiological effects of the proton beam, RBE and the time factor, estimated in human skin in multi-fractional treatment were slightly smaller than those of X-rays, i.e., 0.92 and -0.25±0.09, respectively. (author)

  5. Silicon/HfO2 interface: Effects of proton irradiation

    International Nuclear Information System (INIS)

    Maurya, Savita; Radhakrishna, M.

    2015-01-01

    Substrate oxide interfaces are of paramount importance in deciding the quality of the semiconductor devices. In this work we have studied how 200 keV proton irradiation affects the interface of a 13 nm thick, atomic layer deposited hafnium dioxide on silicon substrate. Pre- and post-irradiation electrical measurements are used to quantify the effect of proton irradiation for varying electrode geometries. Proton irradiation introduces positive charge in the oxide and at the interface of Si/HfO 2 interface. The gate current is not very much affected under positive injection since the induced positive charge is compensated by the injected electrons. Current voltage characteristics under negative bias get affected by the proton irradiation

  6. Proton permeability of membranes of Streptococcus faecalis and submitochondrial particles of rats after irradiation

    International Nuclear Information System (INIS)

    Fomenko, B.S.; Pinchukova, V.A.

    1977-01-01

    It has been shown that at a changed, by HCl impulse, pH of Streptococcus faecalis suspension and submitochondrial liver particles (SLP) of rats, H + concentration decreases more rapidly in the irradiated bacteria and SLP than in the controls. The curves of energy dependence of accumulation of the penetrating ions were also displaced toward the alkaline zone depending on pH. These effects are suggested to be connected with an increased proton permeability of irradiated membranes

  7. Characterization of Czochralski Silicon Detectors

    OpenAIRE

    Luukka, Panja-Riina; Haerkoenen, Jaakko

    2012-01-01

    This thesis describes the characterization of irradiated and non-irradiated segmenteddetectors made of high-resistivity (>1 kΩcm) magnetic Czochralski (MCZ) silicon. It isshown that the radiation hardness (RH) of the protons of these detectors is higher thanthat of devices made of traditional materials such as Float Zone (FZ) silicon or DiffusionOxygenated Float Zone (DOFZ) silicon due to the presence of intrinsic oxygen (> 5 x1017 cm-3). The MCZ devices therefore present an interesting alter...

  8. Defect characterization in high-purity silicon after γ- and hadron irradiation

    International Nuclear Information System (INIS)

    Stahl, J.

    2004-07-01

    The challenge for silicon particle detectors in future high energy physics experiments caused by extreme radiation fields can only be met by an appropriate defect engineering of the starting material. Appreciable improvements had already been obtained by enriching high resistivity float zone silicon with oxygen as demonstrated by the CERN RD48 collaboration. This thesis will focus on the difference observed after irradiation between standard and oxygenated float zone and detector grade Czochralski silicon. Results obtained with diodes manufactured on epitaxial layers are also included, envisioning effects arising from the possible migration of impurities during the crystal growth from the oxygen rich Czochralski substrate. Deep level transient spectroscopy (DLTS) and thermally stimulated current (TSC) measurements have been performed for defect characterization after γ- and hadron irradiation. Also a new high resolution DLTS technique has been used for the first time to separate defect levels with similar parameters. During the microscopic studies additionally to the well known defects like VO i , V 2 , C i O i or VP, four new radiation induced defects have been discovered and characterized. Two of these defects are closely correlated with the detector performance: A deep acceptor labeled as I-defect, and a bistable donor (BD). The formation of the I-defect is strongly suppressed in oxygen rich materials, while the formation of the BD is suppressed in oxygen lean material. With their properties the I- and the BD-defect are able to explain the different macroscopic behavior of standard and oxygen enriched float zone silicon after γ-irradiation. Furthermore, the BD defect is most probably responsible for the observation that in Cz and Epi diodes space charge sign inversion does not occur even after high fluences of proton irradiation. Additionally the γ-irradiated diodes were annealed at temperatures between 100 C and 350 C. During these studies some new reaction

  9. Effect of Proton Irradiation on the Corrosion Behaviors of Ferritic/Martensitic Steel in Liquid Metal Environment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeonghyeon; Kim, Tae Yong; Kim, Ji Hyun [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Liquid metal fast breeder reactors (LMFBRs) such as sodium-cooled fast reactor (SFR) and lead-cooled fast reactor (LFR) are the candidates of GEN-IV nuclear energy systems. Among various liquid metals that can be used as primary coolant material, sodium is a world widely used coolant for GEN-IV reactors. In this study, as-received Gr.92 and irradiated Gr.92 specimen in the oxygen-saturated liquid sodium were examined at high temperature for 300h. The microstructure results reveal the information of the effect of irradiation and effect of the chrome concentration in specimen. From the SRIM result, penetration distance of 40 μm in stainless steel and nominal sample thickness of 30 μm was used to avoid the damage peak and any proton implantation and From the microstructural evaluation, chromium-rich zones existed under the surface of the both of non-irradiated and irradiated materials. The irradiated materials showed chromium-rich zones with larger depths than the non-irradiated specimens.

  10. GINES: first rice mutant obtained from proton irradiation

    International Nuclear Information System (INIS)

    Gonzalez, Maria C; Perez, Noraida; Cristo, Elizabeth

    2009-01-01

    A new rice variety of a good productive potential and salinity tolerance was obtained at the National Institute of Agricultural Sciences (INCA), starting from in vitro culture of J-104 rice seeds irradiated with protons. This is the first report of a variety achieved by proton irradiation

  11. A study on the proton irradiation effect of reactor materials using cyclotron

    International Nuclear Information System (INIS)

    Chi, Se Hwan; Park, Jong Man; Park, Deuk Keun; Lee, Bong Sang; Oh, Jong Myung

    1993-02-01

    Understanding on radiation damage of important structural materials is important for safe operation and radiation damage evaluation of new reactor structural materials. This study was performed to simulate and evaluate 14 MeV neutron irradiation effects on mechanical properties of candidate structural materials (HT-9/SS316) of next generation reactors (FBR, Fusion) irradiated by Cyclotron(MC-50) using SP test technique. After qualification of SP test techniques from J IC and ε qf correlation, SP tests were performed to evaluate 16MeV proton irradiation effects on mechanical properties of irradiated and unirradiated HT-9/SS316 steels. Test results were evaluated for ε qf , energy and displacement up to failure and J IC change. In addition, damaged zone and dpa upon depth after irradiation were calculated using TRIM code and Doppler broadening line shapes were measured to evaluate defects for 15% cold worked HT-9 steel using PAS. (Author)

  12. Proton irradiation effects on beryllium – A macroscopic assessment

    Energy Technology Data Exchange (ETDEWEB)

    Simos, Nikolaos, E-mail: simos@bnl.gov [Nuclear Sciences & Technology Department, Brookhaven National Laboratory, Upton, NY, 11973 (United States); Elbakhshwan, Mohamed [Nuclear Sciences & Technology Department, Brookhaven National Laboratory, Upton, NY, 11973 (United States); Zhong, Zhong [Photon Sciences, NSLS II, Brookhaven National Laboratory, Upton, NY, 11973 (United States); Camino, Fernando [Center for Functional Nanomaterials, Brookhaven National Laboratory, Upton, NY, 11973 (United States)

    2016-10-15

    Beryllium, due to its excellent neutron multiplication and moderation properties, in conjunction with its good thermal properties, is under consideration for use as plasma facing material in fusion reactors and as a very effective neutron reflector in fission reactors. While it is characterized by unique combination of structural, chemical, atomic number, and neutron absorption cross section it suffers, however, from irradiation generated transmutation gases such as helium and tritium which exhibit low solubility leading to supersaturation of the Be matrix and tend to precipitate into bubbles that coalesce and induce swelling and embrittlement thus degrading the metal and limiting its lifetime. Utilization of beryllium as a pion production low-Z target in high power proton accelerators has been sought both for its low Z and good thermal properties in an effort to mitigate thermos-mechanical shock that is expected to be induced under the multi-MW power demand. To assess irradiation-induced changes in the thermal and mechanical properties of Beryllium, a study focusing on proton irradiation damage effects has been undertaken using 200 MeV protons from the Brookhaven National Laboratory Linac and followed by a multi-faceted post-irradiation analysis that included the thermal and volumetric stability of irradiated beryllium, the stress-strain behavior and its ductility loss as a function of proton fluence and the effects of proton irradiation on the microstructure using synchrotron X-ray diffraction. The mimicking of high temperature irradiation of Beryllium via high temperature annealing schemes has been conducted as part of the post-irradiation study. This paper focuses on the thermal stability and mechanical property changes of the proton irradiated beryllium and presents results of the macroscopic property changes of Beryllium deduced from thermal and mechanical tests.

  13. Proton irradiation effects on gallium nitride-based devices

    Science.gov (United States)

    Karmarkar, Aditya P.

    Proton radiation effects on state-of-the-art gallium nitride-based devices were studied using Schottky diodes and high electron-mobility transistors. The device degradation was studied over a wide range of proton fluences. This study allowed for a correlation between proton irradiation effects between different types of devices and enhanced the understanding of the mechanisms responsible for radiation damage in GaN-based devices. Proton irradiation causes reduced carrier concentration and increased series resistance and ideality factor in Schottky diodes. 1.0-MeV protons cause greater degradation than 1.8-MeV protons because of their higher non-ionizing energy loss. The displacement damage in Schottky diodes recovers during annealing. High electron-mobility transistors exhibit extremely high radiation tolerance, continuing to perform up to a fluence of ˜1014 cm-2 of 1.8-MeV protons. Proton irradiation creates defect complexes in the thin-film structure. Decreased sheet carrier mobility due to increased carrier scattering and decreased sheet carrier density due to carrier removal by the defect centers are the primary damage mechanisms. Interface disorder at either the Schottky or the Ohmic contact plays a relatively unimportant part in overall device degradation in both Schottky diodes and high electron-mobility transistors.

  14. Technique for sparing previously irradiated critical normal structures in salvage proton craniospinal irradiation

    International Nuclear Information System (INIS)

    McDonald, Mark W; Wolanski, Mark R; Simmons, Joseph W; Buchsbaum, Jeffrey C

    2013-01-01

    Cranial reirradiation is clinically appropriate in some cases but cumulative radiation dose to critical normal structures remains a practical concern. The authors developed a simple technique in 3D conformal proton craniospinal irradiation (CSI) to block organs at risk (OAR) while minimizing underdosing of adjacent target brain tissue. Two clinical cases illustrate the use of proton therapy to provide salvage CSI when a previously irradiated OAR required sparing from additional radiation dose. The prior radiation plan was coregistered to the treatment planning CT to create a planning organ at risk volume (PRV) around the OAR. Right and left lateral cranial whole brain proton apertures were created with a small block over the PRV. Then right and left lateral “inverse apertures” were generated, creating an aperture opening in the shape of the area previously blocked and blocking the area previously open. The inverse aperture opening was made one millimeter smaller than the original block to minimize the risk of dose overlap. The inverse apertures were used to irradiate the target volume lateral to the PRV, selecting a proton beam range to abut the 50% isodose line against either lateral edge of the PRV. Together, the 4 cranial proton fields created a region of complete dose avoidance around the OAR. Comparative photon treatment plans were generated with opposed lateral X-ray fields with custom blocks and coplanar intensity modulated radiation therapy optimized to avoid the PRV. Cumulative dose volume histograms were evaluated. Treatment plans were developed and successfully implemented to provide sparing of previously irradiated critical normal structures while treating target brain lateral to these structures. The absence of dose overlapping during irradiation through the inverse apertures was confirmed by film. Compared to the lateral X-ray and IMRT treatment plans, the proton CSI technique improved coverage of target brain tissue while providing the least

  15. Characterization of Czochralski silicon detectors

    OpenAIRE

    Luukka, Panja-Riina

    2006-01-01

    This thesis describes the characterization of irradiated and non-irradiated segmented detectors made of high-resistivity (>1 kΩcm) magnetic Czochralski (MCZ) silicon. It is shown that the radiation hardness (RH) of the protons of these detectors is higher than that of devices made of traditional materials such as Float Zone (FZ) silicon or Diffusion Oxygenated Float Zone (DOFZ) silicon due to the presence of intrinsic oxygen (> 5 × 1017 cm−3). The MCZ devices therefore present an interesting ...

  16. Of floating-zone uranium; Sur l'uranium de zone flottante

    Energy Technology Data Exchange (ETDEWEB)

    Clottes, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-01-01

    The floating zone method has been chosen in order to purify uranium. The various parameters occurring in this purification technique, have been studied theoretically and technologically. The speed that proves to be the most efficient is 0,7 cm/h, the direction can only upwards, and the fusion must take place under pressure of 10{sup -7} Torr or so. Besides such problems concerning purification, the study of the floating zone stability led us to define a field touching the size and diameter of uranium drops, which, on the one hand coincides with Heywang's conditions and, on the other hand, is compatible with a fusion in the core of the bar. Such field shows that the floating zone can easily apply to bars whose diameter is included between 5 and 10 mm, and that it cannot work out when the diameter exceeds 21 mm. The apparatus, consisting in a means of heating by electronic bombardment under ultra-vacuum is conditioned by the various parameters that have been studied. As the analysis results were insufficient, the uranium thus dealt with has been characterized by metallurgic and physical tests: micrographic tests, measures of microhardness, measures of electric resistivity at a low temperature, have shown a definite purification at the bar-head; these results have been confirmed by the lowering at 270 C of the temperature of recrystallization together with the definite tendency of the refined metal to polygonize. The measures of electric resistivity constitute an easy and quantitative way of figuring out the metal purity. The influence of an impurity on the electric resistivity of uranium has been studied by U-Au alloys with a weak concentration of gold. The two important following points are brought out be these experiences: 1 - the measure of electric resistivity should be worked out on anneal bars in {gamma} phase and cooled. 2 - Gold has a very strong influence on uranium; the value 500 {mu}{omega}cm per cent of gold enabled us to give a total concentration of 20

  17. Ferromagnetism in proton irradiated 4H-SiC single crystal

    Directory of Open Access Journals (Sweden)

    Ren-Wei Zhou

    2015-04-01

    Full Text Available Room-temperature ferromagnetism is observed in proton irradiated 4H-SiC single crystal. An initial increase in proton dose leads to pronounced ferromagnetism, accompanying with obvious increase in vacancy concentration. Further increase in irradiation dose lowers the saturation magnetization with the decrease in total vacancy defects due to the defects recombination. It is found that divacancies are the mainly defects in proton irradiated 4H-SiC and responsible for the observed ferromagnetism.

  18. Positron lifetime study of copper irradiated by energetic protons or energetic neutrons

    International Nuclear Information System (INIS)

    Howell, R.H.

    1979-03-01

    Positron lifetime measurements of pure copper damaged by irradiation with energetic protons and neutrons are presented. Lifetime determinations of the bulk material and various traps were made, and the dependence of the trapping rate on dose and irradiation energy were investigated. The results from the neutron- and proton-irradiated samples point to the existence of traps with similar but distinct lifetime parameters, not varying greatly from values reported in deformation studies. Also, a trap with long lifetime is seen for some proton irradiations, but is never seen for the neutron irradiations. The trapping rate of the short-lifetime trap is a linear function of dose for proton-irradiated samples and nearly so for the neutron irradiation. 1 figure

  19. Modification of polycrystalline copper by proton irradiation

    International Nuclear Information System (INIS)

    Garcia S, F.; Cabral P, A.; Saniger B, J.M.; Banuelos, J.G.; Barragan V, A.

    1997-01-01

    Polished copper samples were irradiated with proton beams of 300 and 700 keV at room temperature and at -150 Centigrade. In this work the obtained results are reported when such copper irradiated samples are analysed with Sem, Tem, AFM. The Sem micrographs showed evident changes in surface of these copper samples, therefore an EDAX microanalysis was done for its characterization. additionally, the Tem micrographs showed heaps formation until 200 nm. Its electron diffraction spectra indicated that these heaps consist of a copper compound. Finally with AFM were observed changes in coloration of the irradiated sample surface, as well as changes in texture and rugosity of them. These results show in general that irradiation process with protons which is known as an innocuo process produces changes in the copper properties. (Author)

  20. Preparation of HfC single crystals by a floating zone technique

    International Nuclear Information System (INIS)

    Otani, S.; Tanaka, T.

    1981-01-01

    HfC single crystals have been prepared using a floating zone technique by controlling the compositions of the initial molten zone and the feed rod. The obtained crystal rods were 6 cm long and 0.9 cm in diameter. The various parts of the crystal rods have nearly constant compositions (C/Hf(ZR) = 0.956-0.977), and do not contain any free carbon. The impurities in the crystal, evaporation product, and starting material were examined by fluorescence X-ray spectroscopy. The refining effect due to evaporation was discussed. (orig.)

  1. Precipitation in Zr-2.5Nb enhanced by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cann, C. D.; So, C. B.; Styles, R. C.; Coleman, C. E.

    1993-08-15

    A 3.6 MeV proton irradiation of annealed Zr-2.5Nb has been performed to determine whether proton irradiation will enhance the precipitation of Nb-rich {beta}-phase precipitates within the {alpha}-grains. a transmission electron microscope examination of a foil after irradiation at 770 K for 18 h and at 720 K for 264.5 h to a total damage of 0.94 dpa revealed a fine dispersion of precipitates within the {alpha}-grains. Electron diffraction analysis of the precipitates found they have lattice plane spacings consistent with the Nb-rich {beta}-phase. This result is in agreement with the {beta}phase precipitation observed following neutron irradiation, and thus it supports the use of proton irradiation to simulate neutron-irradiation effects in Zr-2.5Nb.

  2. Precipitation in Zr-2.5Nb enhanced by proton irradiation

    International Nuclear Information System (INIS)

    Cann, C.D.; So, C.B.; Styles, R.C.; Coleman, C.E.

    1993-08-01

    A 3.6 MeV proton irradiation of annealed Zr-2.5Nb has been performed to determine whether proton irradiation will enhance the precipitation of Nb-rich β-phase precipitates within the α-grains. a transmission electron microscope examination of a foil after irradiation at 770 K for 18 h and at 720 K for 264.5 h to a total damage of 0.94 dpa revealed a fine dispersion of precipitates within the α-grains. Electron diffraction analysis of the precipitates found they have lattice plane spacings consistent with the Nb-rich β-phase. This result is in agreement with the βphase precipitation observed following neutron irradiation, and thus it supports the use of proton irradiation to simulate neutron-irradiation effects in Zr-2.5Nb

  3. Dielectric properties of proton irradiated PES

    International Nuclear Information System (INIS)

    Shah, Nilam; Singh, N.L.; Singh, K.P.

    2005-01-01

    Polyethersulfone films were irradiated with 3 MeV proton beam at fluences ranging from 10 13 to 10 15 ions/cm 2 . AC electrical properties of irradiated samples were studied in the frequency range 100 Hz to 1MHz by LCR meter. There is an exponential increase in conductivity with frequency but the effect of irradiation is not significant. The dielectric loss/constant are observed to change with fluence. (author)

  4. Development of floating strip micromegas detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, Jonathan

    2014-04-28

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10{sup 34} cm{sup -2}s{sup -1} around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm{sup 2} floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm{sup 2} floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm{sup 2} floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the

  5. Development of floating strip micromegas detectors

    International Nuclear Information System (INIS)

    Bortfeldt, Jonathan

    2014-01-01

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10 34 cm -2 s -1 around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm 2 floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm 2 floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm 2 floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the track inclination in a single

  6. Luminescence imaging of water during proton-beam irradiation for range estimation

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Okumura, Satoshi; Komori, Masataka [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya 461-8673 (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya 462-8508 (Japan)

    2015-11-15

    Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy.

  7. Luminescence imaging of water during proton-beam irradiation for range estimation

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Okumura, Satoshi; Komori, Masataka; Toshito, Toshiyuki

    2015-01-01

    Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy

  8. Activation of 45-MeV proton irradiation and proton-induced neutron irradiation in polymers

    International Nuclear Information System (INIS)

    Ra, Se-Jin; Kim, Kye-Ryung; Jung, Myung-Hwan; Yang, Tae-Keon

    2010-01-01

    During beam irradiation experiments with more than a few MeV energetic protons, the sample activation problem can be very severe because it causes many kinds of additional problems for the post-processing of the samples, such as time loss, inconvenience of sample handling, personal radiation safety, etc. The most serious problem is that immediate treatment of the sample is impossible in some experiments, such as nano-particle synthesizing. To solve these problems, we studied why the samples are activated and how the level of the activation can be reduced. It is known that the main reasons of activation are nuclear reactions with elements of the target material by primary protons and secondary produced neutrons. Even though the irradiation conditions are same, the level of the activation can be different depending on the target materials. For the nanoparticle synthesizing experiments, the target materials can be defined as the container and the sample itself. The reduction of the activation from the container is easier than the reduction from the sample. Therefore, we tried to reduce the activation level by changing the container materials. In this paper, the results are displayed for some candidate container materials, such as polymethyl methacrylate, polystyrene, Glass, etc., with 45-MeV and 10-nA proton beams. As a result, PS is the most suitable material for the container because of its relatively low level of the activation by protons. Also the contribution of secondary produced neutrons to the activation is negligible.

  9. Proton irradiation of liquid crystal based adaptive optical devices

    International Nuclear Information System (INIS)

    Buis, E.J.; Berkhout, G.C.G.; Love, G.D.; Kirby, A.K.; Taylor, J.M.; Hannemann, S.; Collon, M.J.

    2012-01-01

    To assess its radiation hardness, a liquid crystal based adaptive optical element has been irradiated using a 60 MeV proton beam. The device with the functionality of an optical beam steerer was characterised before, during and after the irradiation. A systematic set of measurements on the transmission and beam deflection angles was carried out. The measurements showed that the transmission decreased only marginally and that its optical performance degraded only after a very high proton fluence (10 10 p/cm 2 ). The device showed complete annealing in the functionality as a beam steerer, which leads to the conclusion that the liquid crystal technology for optical devices is not vulnerable to proton irradiation as expected in space.

  10. Proton irradiation of liquid crystal based adaptive optical devices

    Energy Technology Data Exchange (ETDEWEB)

    Buis, E.J., E-mail: ernst-jan.buis@tno.nl [cosine Science and Computing BV, Niels Bohrweg 11, 2333 CA Leiden (Netherlands); Berkhout, G.C.G. [cosine Science and Computing BV, Niels Bohrweg 11, 2333 CA Leiden (Netherlands); Huygens Laboratory, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Love, G.D.; Kirby, A.K.; Taylor, J.M. [Department of Physics, Durham University, South Road, Durham DH1 3LE (United Kingdom); Hannemann, S.; Collon, M.J. [cosine Research BV, Niels Bohrweg 11, 2333 CA Leiden (Netherlands)

    2012-01-01

    To assess its radiation hardness, a liquid crystal based adaptive optical element has been irradiated using a 60 MeV proton beam. The device with the functionality of an optical beam steerer was characterised before, during and after the irradiation. A systematic set of measurements on the transmission and beam deflection angles was carried out. The measurements showed that the transmission decreased only marginally and that its optical performance degraded only after a very high proton fluence (10{sup 10}p/cm{sup 2}). The device showed complete annealing in the functionality as a beam steerer, which leads to the conclusion that the liquid crystal technology for optical devices is not vulnerable to proton irradiation as expected in space.

  11. Surface, structural and tensile properties of proton beam irradiated zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Rafique, Mohsin; Chae, San; Kim, Yong-Soo, E-mail: yongskim@hanyang.ac.kr

    2016-02-01

    This paper reports the surface, structural and tensile properties of proton beam irradiated pure zirconium (99.8%). The Zr samples were irradiated by 3.5 MeV protons using MC-50 cyclotron accelerator at different doses ranging from 1 × 10{sup 13} to 1 × 10{sup 16} protons/cm{sup 2}. Both un-irradiated and irradiated samples were characterized using Field Emission Scanning Electron Microscope (FESEM), X-ray Diffraction (XRD) and Universal Testing Machine (UTM). The average surface roughness of the specimens was determined by using Nanotech WSxM 5.0 develop 7.0 software. The FESEM results revealed the formation of bubbles, cracks and black spots on the samples’ surface at different doses whereas the XRD results indicated the presence of residual stresses in the irradiated specimens. Williamson–Hall analysis of the diffraction peaks was carried out to investigate changes in crystallite size and lattice strain in the irradiated specimens. The tensile properties such as the yield stress, ultimate tensile stress and percentage elongation exhibited a decreasing trend after irradiation in general, however, an inconsistent behavior was observed in their dependence on proton dose. The changes in tensile properties of Zr were associated with the production of radiation-induced defects including bubbles, cracks, precipitates and simultaneous recovery by the thermal energy generated with the increase of irradiation dose.

  12. Surface, structural and tensile properties of proton beam irradiated zirconium

    Science.gov (United States)

    Rafique, Mohsin; Chae, San; Kim, Yong-Soo

    2016-02-01

    This paper reports the surface, structural and tensile properties of proton beam irradiated pure zirconium (99.8%). The Zr samples were irradiated by 3.5 MeV protons using MC-50 cyclotron accelerator at different doses ranging from 1 × 1013 to 1 × 1016 protons/cm2. Both un-irradiated and irradiated samples were characterized using Field Emission Scanning Electron Microscope (FESEM), X-ray Diffraction (XRD) and Universal Testing Machine (UTM). The average surface roughness of the specimens was determined by using Nanotech WSxM 5.0 develop 7.0 software. The FESEM results revealed the formation of bubbles, cracks and black spots on the samples' surface at different doses whereas the XRD results indicated the presence of residual stresses in the irradiated specimens. Williamson-Hall analysis of the diffraction peaks was carried out to investigate changes in crystallite size and lattice strain in the irradiated specimens. The tensile properties such as the yield stress, ultimate tensile stress and percentage elongation exhibited a decreasing trend after irradiation in general, however, an inconsistent behavior was observed in their dependence on proton dose. The changes in tensile properties of Zr were associated with the production of radiation-induced defects including bubbles, cracks, precipitates and simultaneous recovery by the thermal energy generated with the increase of irradiation dose.

  13. Changes in optical properties of polystyrene thin films by proton beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Hyun; Jung, Jin Mook; Choi, Jae Hak [Dept. of of Polymer Science and Engineering, Chungnam National University, Daejeon (Korea, Republic of); Jung, Chan Hee; Hwang, In Tae; Shin, Jun Hwa [Research Division for Industry and Environment, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup(Korea, Republic of)

    2017-06-15

    In this study, changes in optical properties of polystyrene (PS) thin films by proton irradiation were investigated. PS thin films were irradiated with 150 keV proton ions at fluences ranging from 1 × 10{sup 15} to 1 × 10{sup 16} ions cm{sup -2}. The chemical structures and optical properties of proton beam-irradiated PS thin films were investigated by using a FT-IR spectrometer, an UVvis spectrophotometer, a photoluminescence (PL) and a fluorescence microscope. The results of the chemical structure analysis revealed that chemical functional groups, such as OH, C=O, and C=C, were formed in the PS films due to the oxidation and formation of carbon clusters by proton beam irradiation. The PL emission was generated and gradually red-shifted with an increasing fluence due to the higher formation of sp2 carbon clusters by proton beam irradiation. The highest PL intensity was obtained at a fluence of 5×10{sup 15} ions cm{sup -2}. The optical band gap of PS calculated by using a Tauc’s plot decreased with increasing the fluence due to the formation of sp2 carbon clusters by proton beam irradiation.

  14. Positron annihilation lifetime in float-zone n-type silicon irradiated by fast electrons: a thermally stable vacancy defect

    International Nuclear Information System (INIS)

    Arutyunov, Nikolay; Emtsev, Vadim; Oganesyan, Gagik; Krause-Rehberg, Reinhard; Elsayed, Mohamed; Kozlovskii, Vitalii

    2016-01-01

    Temperature dependency of the average positron lifetime has been investigated for n-type float-zone silicon, n-FZ-Si(P), subjected to irradiation with 0.9 MeV electrons at RT. In the course of the isochronal annealing a new defect-related temperature-dependent pattern of the positron lifetime spectra has been revealed. Beyond the well known intervals of isochronal annealing of acceptor-like defects such as E-centers, divacancies and A-centers, the positron annihilation at the vacancy defects has been observed in the course of the isochronal annealing from ∝ 320 C up to the limit of reliable detecting of the defect-related positron annihilation lifetime at ≥ 500 C. These data correlate with the ones of recovery of the concentration of the charge carriers and their mobility which is found to continue in the course of annealing to ∝ 570 C; the annealing is accomplished at ∝650 C. A thermally stable complex consisting of the open vacancy volume and the phosphorus impurity atom, V_o_p-P, is suggested as a possible candidate for interpreting the data obtained by the positron annihilation lifetime spectroscopy. An extended couple of semi-vacancies, 2V_s_-_e_x_t, as well as a relaxed inwards a couple of vacancies, 2V_i_n_w, are suggested as the open vacancy volume V_o_p to be probed with the positron. It is argued that a high thermal stability of the V_s_-_e_x_t PV_s_-_e_x_t (or V_i_n_wPV_i_n_w_.) configuration is contributed by the efficiency of PSi_5 bonding. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Electrical characterization of proton irradiated p+-n-n+ Si diode

    International Nuclear Information System (INIS)

    Kim, J.H.; Lee, D.U.; Kim, E.K.; Bae, Y.H.

    2006-01-01

    Electrical characterization of p + -n-n + Si power electric diodes was done with proton irradiation. The kinetic energies of irradiated protons were 2.32, 2.55 and 2.97MeV, and for each energy condition, doses of 1x10 11 , 1x10 12 and 1x10 13 cm -2 were given. By modulating the kinetic energy, the proton penetration depth into Si crystal could be adjusted to the range of 55-90μm, and then controlled to the special depth regions such as junction region, depletion region and neutral region over the depletion layer in the p + -n-n + diode structure. Defects produced by the proton irradiation affected to electrical property of the Si diode because of their carrier trapping, and then the reverse recovery time was improved from 240 to 50ns. It appeared that the defect states with activation energies of 0.47 and 0.54eV may be responsible for the decrease of the minority carrier lifetime in the proton-irradiated diode with 2.97MeV energy and 1x10 13 cm -2 doses

  16. Inactivation of HTB63 human melanoma cells by irradiation with protons and gamma rays.

    Science.gov (United States)

    Ristic-Fira, Aleksandra; Petrovic, Ivan; Todorovic, Danijela; Koricanac, Lela; Vujèic, Miroslava; Demajo, Miroslav; Sabini, Gabriella; Cirrone, Pablo; Cuttone, Giacomo

    2004-12-01

    The effects of single irradiation with gamma rays and protons on HTB63 human melanoma cell growth were compared. The exponentially growing cells were irradiated with gamma rays or protons using doses ranging from 2-20 Gy. At 48 h of post-irradiation incubation under standard conditions, cell survival and induction of apoptotic cell death were examined. The best effect of the single irradiation with gamma rays was the reduction of cell growth by up to 26% (p=0.048, irradiation vs. control), obtained using the dose of 16 Gy. The same doses of proton irradiation, having energy at the target of 22.6 MeV, significantly inhibited melanoma cell growth. Doses of 12 and 16 Gy of protons provoked growth inhibition of 48.9% (p=0.003, irradiation vs. control) and 51.2% (p=0.012, irradiation vs. control) respectively. Irradiation with 12 and 16 Gy protons, compared to the effects of the same doses of gamma rays, significantly reduced melanoma cell growth (p=0.015 and p=0.028, protons vs. gamma rays, respectively). Estimated RBEs for growth inhibition of HTB63 cells ranged from 1.02 to 1.45. The electrophoretical analyses of DNA samples and flow cytometric evaluation have shown a low percentage of apoptotic cells after both types of irradiation. The better inhibitory effect achieved by protons in contrast to gamma rays, can be explained considering specific physical properties of protons, especially taking into account the highly localized energy deposition (high LET).

  17. Impact of irradiations by protons with different energies on silicon sensors

    International Nuclear Information System (INIS)

    Neubueser, Coralie

    2013-06-01

    In the frame of the CMS tracker upgrade campaign the radiation damage of oxygenrich n-type silicon pad diodes induced by 23 MeV and 23 GeV protons was investigated. The diodes were manufactured by Hamamatsu Photonics. After irradiation with 1 MeV neutron equivalent fluences between 1 x 10 11 cm -2 and 1.5 x 10 15 cm -2 , the sensors were electrically characterized by means of capacitance-voltage (CV) and current-voltage (IV) measurements. Current pulses recorded by the Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements show a dependence of the bulk damage on the proton energy. At a fluence of Φ eq ∼3 x 10 14 cm -2 oxygen-rich n-type diodes demonstrate clear Space Charge Sign Inversion (SCSI) after 23 MeV proton irradiation. This effect does not appear after the irradiation with 23 GeV protons. Moreover, RD50 pad diodes were irradiated with 23 MeV protons, electrically characterized and compared to results obtained after 23 GeV irradiations. Our previous observation on the energy dependence of the radiation damage could be confirmed. In order to get a deeper understanding of the differences of the radiation induced defects, the Deep Level Transient Spectroscopy (DLTS) and Thermally Stimulated Current Technique (TSC) were utilized. Defects with impact on the space charge could be identified and characterized and it was possible to find some hints for the reason of the SCSI after 23 MeV proton irradiation. Moreover, a dependence on the oxygen concentration of the sensors could be observed.

  18. Effect of proton irradiation on photoluminescent properties of PDMS-nanodiamond composites

    International Nuclear Information System (INIS)

    Borjanovic, Vesna; Hens, Suzanne; Shenderova, Olga; McGuire, Gary E; Lawrence, William G; Edson, Clark; Jaksic, Milko; Zamboni, Ivana; Vlasov, Igor

    2008-01-01

    Pure poly(dimethylsiloxane) (PDMS) films, PDMS-nanodiamond (ND) and pure nanodiamond powder were irradiated with 2 MeV protons under a variety of fluence and current conditions. Upon proton irradiation, these samples acquire a fluence-dependent photoluminescence (PL). The emission and excitation spectra, photostability and emission lifetime of the induced photoluminescence of PDMS and PDMS-ND samples are reported. Pure PDMS exhibits a noticeable stable blue PL, while the PDMS-ND composites exhibit a pronounced stable green PL under 425 nm excitation. The PL of PDMS-ND composites is much more prominent than that of pure PDMS or pure ND powder even when irradiated at higher doses. The origin of the significantly enhanced PL intensity for the proton-irradiated PDMS-ND composite is explained by the combination of enhanced intrinsic PL within ND particles due to ion-implantation-generated defects and by PL originating from structural transformations produced by protons at the nanodiamond/matrix interface.

  19. Photoluminescence study of high energy proton irradiation on Cu(In,Ga)Se{sub 2} thin films

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Bonhyeong [Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Lee, June Hyuk [Neutron Science Division, Korea Atomic Energy Research Institute (KAERI), 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Shin, Donghyeop [Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708 (United States); Ahn, Byung Tae, E-mail: btahn@kaist.ac.kr [Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Shin, Byungha, E-mail: byungha@kaist.ac.kr [Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2016-03-31

    We have studied the effect of proton irradiation on Cu(In,Ga)Se{sub 2} (CIGS) thin films using photoluminescence (PL). We used a 10 MeV proton beam with varying doses from 10{sup 9} to 10{sup 12} cm{sup −2}. Intensity-dependent low temperature PL measurements suggest that the proton irradiation does not create a new defect level but instead changes the number of preexisting defects in the detection range of the PL system. By comparing PL spectra after the proton irradiation with those obtained after thermal annealing under inert gas as well as under hydrogen gas ambient, we find that the irradiation-induced change in the defect structure does not originate from the incorporation of hydrogen but from energetics of the irradiating particles. Electrical resistivity of the proton irradiated CIGS thin films is shown to decrease after the proton irradiation, and this is explained by the reduction of the concentration of compensating donor-like defects, specifically selenium vacancies, based on the PL results. - Highlights: • Photoluminescence study of 10 MeV proton irradiation on CIGS at 10 K. • Irradiation modified population of existing defects without introducing new levels. • Changes in CIGS by 10 MeV irradiation are due to energetics of irradiating protons.

  20. Proton irradiation effects on optical attenuation in doped- and pure-silica fibers

    International Nuclear Information System (INIS)

    Sakasai, Kaoru; Bueker, H.; Haesing, F.W.; Pfeiffer, F.

    1999-05-01

    Optical attenuation in doped- and pure-silica fibers was measured at wavelengths of 470 nm, 660 nm, and 850 nm during and after 20 MeV proton irradiation. In the experiment the fibers were arranged on a holder to make one layer' so that uniform proton irradiation can be achieved to them. The induced loss of the doped-silica fiber increased strongly at the beginning of the first irradiation, and decreased slowly after stopping of the beam. In the second irradiation, however, the developed loss was not so large. On the other hand, the loss of the pure-silica fiber increased gradually in the first irradiation, and decreased very quickly after the beam stopped. The loss increased stepwise at the very beginning of the second irradiation. Small luminescence from the fibers during irradiation was observed also. The luminescence of the pure-silica fiber was slightly larger than that of the doped-silica fiber. The induced loss of HCP fibers was also measured when a SiO 2 plate was set in front of the fibers. It may be possible to estimate the proton dose in materials using fiber-optic technique. Proton sensitivities of doped- and pure-silica fibers were, respectively, 1.0 x 10 -10 at 660 nm and 5.5 x 10 -12 at 470 nm in units of (dB/m)/(protons/cm 2 ), where the values were estimated from the slope of the loss growth curves at the beginning of the first irradiation. (author)

  1. Impact of irradiations by protons with different energies on silicon sensors

    Energy Technology Data Exchange (ETDEWEB)

    Neubueser, Coralie

    2013-06-15

    In the frame of the CMS tracker upgrade campaign the radiation damage of oxygenrich n-type silicon pad diodes induced by 23 MeV and 23 GeV protons was investigated. The diodes were manufactured by Hamamatsu Photonics. After irradiation with 1 MeV neutron equivalent fluences between 1 x 10{sup 11} cm{sup -2} and 1.5 x 10{sup 15} cm{sup -2}, the sensors were electrically characterized by means of capacitance-voltage (CV) and current-voltage (IV) measurements. Current pulses recorded by the Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements show a dependence of the bulk damage on the proton energy. At a fluence of {Phi}{sub eq}{approx}3 x 10{sup 14} cm{sup -2} oxygen-rich n-type diodes demonstrate clear Space Charge Sign Inversion (SCSI) after 23 MeV proton irradiation. This effect does not appear after the irradiation with 23 GeV protons. Moreover, RD50 pad diodes were irradiated with 23 MeV protons, electrically characterized and compared to results obtained after 23 GeV irradiations. Our previous observation on the energy dependence of the radiation damage could be confirmed. In order to get a deeper understanding of the differences of the radiation induced defects, the Deep Level Transient Spectroscopy (DLTS) and Thermally Stimulated Current Technique (TSC) were utilized. Defects with impact on the space charge could be identified and characterized and it was possible to find some hints for the reason of the SCSI after 23 MeV proton irradiation. Moreover, a dependence on the oxygen concentration of the sensors could be observed.

  2. Vacancy-type defects in electron and proton irradiated II-VI compounds

    International Nuclear Information System (INIS)

    Brunner, S.; Puff, W.; Balogh, A.G.; Baumann, H.

    1997-01-01

    In this contribution, the authors present a study aimed at investigating the basic properties of radiation induced defects in ZnS and ZnO and the influence of the atmosphere on the annealing characteristics of the defects. Positron annihilation experiments (both lifetime and Doppler-broadening measurements) were performed on both single- and polycrystalline samples, irradiated with 3 MeV protons or 1 MeV electrons. For ZnS it was found that both electron and proton irradiation caused significant changes in the positron annihilation characteristics. The annealing of proton irradiated ZnS in air leads to significant oxidation and eventual transformation into ZnO

  3. Modification of polycrystalline copper by proton irradiation; Modificacion de cobre policristalino por irradiacion con protones

    Energy Technology Data Exchange (ETDEWEB)

    Garcia S, F.; Cabral P, A. [Instituto Nacional de Investigaciones Nucleares, Hipodromo Condesa, 06100 Mexico D.F. (Mexico); Saniger B, J.M.; Banuelos, J.G. [UNAM Centro de Instrumentos, Mexico D.F. (Mexico); Barragan V, A. [UNAM Instituto de Fisica, Mexico D.F. (Mexico)

    1997-07-01

    Polished copper samples were irradiated with proton beams of 300 and 700 keV at room temperature and at -150 Centigrade. In this work the obtained results are reported when such copper irradiated samples are analysed with Sem, Tem, AFM. The Sem micrographs showed evident changes in surface of these copper samples, therefore an EDAX microanalysis was done for its characterization. additionally, the Tem micrographs showed heaps formation until 200 nm. Its electron diffraction spectra indicated that these heaps consist of a copper compound. Finally with AFM were observed changes in coloration of the irradiated sample surface, as well as changes in texture and rugosity of them. These results show in general that irradiation process with protons which is known as an innocuo process produces changes in the copper properties. (Author)

  4. Proton irradiated graphite grades for a long baseline neutrino facility experiment

    International Nuclear Information System (INIS)

    Simos, N.; Nocera, P.; Zwaska, R.; Mokhov, N.

    2017-01-01

    In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) four graphite grades were irradiated with protons in the energy range of 140–180 MeV, to peak fluence of ~6.1×10"2"0 p/cm"2 and irradiation temperatures between 120–200 °C. The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a) comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b) understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young’s modulus. The proton fluence level of ~10"2"0 cm"-"2 where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite revealed for the first time the similarity in

  5. Proton irradiated graphite grades for a long baseline neutrino facility experiment

    Directory of Open Access Journals (Sweden)

    N. Simos

    2017-07-01

    Full Text Available In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF of the Deep Underground Neutrino Experiment (DUNE four graphite grades were irradiated with protons in the energy range of 140–180 MeV, to peak fluence of ∼6.1×10^{20}  p/cm^{2} and irradiation temperatures between 120–200 °C. The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young’s modulus. The proton fluence level of ∼10^{20}  cm^{−2} where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite

  6. Proton irradiated graphite grades for a long baseline neutrino facility experiment

    Science.gov (United States)

    Simos, N.; Nocera, P.; Zhong, Z.; Zwaska, R.; Mokhov, N.; Misek, J.; Ammigan, K.; Hurh, P.; Kotsina, Z.

    2017-07-01

    In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) four graphite grades were irradiated with protons in the energy range of 140-180 MeV, to peak fluence of ˜6.1 ×1020 p /cm2 and irradiation temperatures between 120 - 200 °C . The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a) comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b) understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young's modulus. The proton fluence level of ˜1020 cm-2 where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite revealed for the first time the similarity in

  7. Structural changes and tribological performance of thermosetting polyimide induced by proton and electron irradiation

    International Nuclear Information System (INIS)

    Lv, Mei; Wang, Yanming; Wang, Qihua; Wang, Tingmei; Liang, Yongmin

    2015-01-01

    The structural changes and tribological performance of thermosetting polyimide were investigated by electron, proton or both combined irradiations at 25 keV in a ground-based simulation facility. Three forms of irradiations could lead to the formation of the carbonized layer on the polymer surface that could increase the hardness and adhesive force of the material. Proton irradiation induced more extensive changes in structure and friction behavior than electron irradiation by reason of the higher linear energy transfer value, and combined irradiation resulted in the largest impact, but which was less than the sum of the radiation effects of electron and proton. Moreover, the experimental results indicated that the changes in friction behavior are closely related with the carbonized layer, which was easily worn out in friction process and could introduce a shift from adhesion wear to three-body abrasive wear that reduced the wear rate and the friction coefficient. The friction process of irradiated samples could be divided into the initial stage and the steady stage. Three forms of irradiations all induced the high friction coefficient in the initial stage and the low friction coefficient in the steady stage, and the wear rate of the irradiated samples decreased in the order: electron irradiation>proton irradiation>combined irradiation. - Highlights: • Proton irradiation induced more extensive changes in structure and friction behavior than electron irradiation. • The effect of combined irradiation was less than that of the sum of electron and proton irradiation. • Three forms of irradiations all induced the high initial friction coefficient and the low steady-stage friction coefficient. • The initial friction stage means a fast-wearing adhesive process while the steady-state of the system is a three-body abrasion

  8. Investigation of microstructure and mechanical properties of proton irradiated Zircaloy 2

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, Apu, E-mail: asarkar@barc.gov.in [Mechanical Metallurgy Division, Bhabha Atomic Reserch Centre, Mumbai, 400 085 (India); Kumar, Ajay [Nuclear Physics Division, Bhabha Atomic Reserch Centre, Mumbai, 400 085 (India); Mukherjee, S.; Sharma, S.K.; Dutta, D.; Pujari, P.K. [Radiochemistry Division, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Agarwal, A.; Gupta, S.K.; Singh, P. [Ion Accelerator Development Division, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Chakravartty, J.K. [Mechanical Metallurgy Division, Bhabha Atomic Reserch Centre, Mumbai, 400 085 (India)

    2016-10-15

    Samples of Zircaloy 2 have been irradiated with 4 MeV protons to two different doses. Microstructures of the unirradiated and irradiated samples have been characterized by Electron Back Scatter Diffraction (EBSD), X-ray diffraction line profile analysis (XRDLPA), Positron Annihilation Lifetime Spectroscopy (PALS) and Coincident Doppler Broadening (CDB) Spectroscopy. Tensile tests and micro hardness measurements have been carried out at room temperature to assess the changes in mechanical properties of Zircaloy 2 due to proton irradiation. The correlation of dislocation density, grain size and yield stress of the irradiated samples indicated that an increase in dislocation density due to irradiation is responsible for the change in mechanical behavior of irradiated Zircaloy.

  9. Doping of 6H-SiC pn structures by proton irradiation

    International Nuclear Information System (INIS)

    Strel'chuk, Anatoly M.; Lebedev, Alexandre A.; Kozlovski, Vitali V.; Savkina, Natali S.; Davydov, Denis V.; Solov'ev, Viktor V.; Rastegaeva, Marina G.

    1999-01-01

    The influence of proton irradiation on current-voltage characteristics, N d - N a values and parameters of deep centres in 6H-SiC pn structures grown by sublimation epitaxy has been studied. The irradiation was carried out with 8 MeV protons in the range of doses from 10 14 to 10 16 cm -2 . Irradiation with a dose of 3.6x10 14 cm -2 leaves the voltage drop at high forward currents (10 A/cm 2 ) practically unchanged. For higher irradiation dose of 1.8x10 15 cm -2 , the forward voltage drop and the degree of compensation in the samples increased ; partial annealing of the radiation defects and partial recovery of the electrical parameters occurred after annealing at T∼400-800 K. Irradiation with a dose of 5.4x10 15 cm -2 resulted in very high resistance in forward biased pn structures which remained high even after heating to 500 deg. C. It is suggested that proton irradiation causes decreasing of the lifetime and formation of an i- or an additional p-layer

  10. Impact of proton irradiation on deep level states in n-GaN

    International Nuclear Information System (INIS)

    Zhang, Z.; Arehart, A. R.; Cinkilic, E.; Ringel, S. A.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; McSkimming, B.; Speck, J. S.

    2013-01-01

    Deep levels in 1.8 MeV proton irradiated n-type GaN were systematically characterized using deep level transient spectroscopies and deep level optical spectroscopies. The impacts of proton irradiation on the introduction and evolution of those deep states were revealed as a function of proton fluences up to 1.1 × 10 13 cm −2 . The proton irradiation introduced two traps with activation energies of E C - 0.13 eV and 0.16 eV, and a monotonic increase in the concentration for most of the pre-existing traps, though the increase rates were different for each trap, suggesting different physical sources and/or configurations for these states. Through lighted capacitance voltage measurements, the deep levels at E C - 1.25 eV, 2.50 eV, and 3.25 eV were identified as being the source of systematic carrier removal in proton-damaged n-GaN as a function of proton fluence

  11. Domain structures of LiNbO3 crystals grown by a floating zone technique

    International Nuclear Information System (INIS)

    Kawakami, Shoji; Ishii, Eiichi; Tsuzuki, Akihiro; Sekiya, Tadashi; Torii, Yasuyoshi; Takahashi, Akio.

    1986-01-01

    LiNbO 3 single crystals were grown from the congruently melting composition by a floating zone technique. It was confirmed by etching that the single domain crystals were produced without applying any external electric field. When annealed above the Curie temperature, antiparallel domain appeared in the form of annual rings. (author)

  12. Irradiation damage 'displacement zone'; Dommages sous irradiation zone de deplacements

    Energy Technology Data Exchange (ETDEWEB)

    Genthon, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    It is well known that a charged particle (ion, primary atom, etc...) moving in a solid slows down and can cause a cascade of displacements of the atoms in the solid. A study is made here of the extent to which the cascade is made up, or not, of independent collisions, as a function of the energy of the initial charged particle. When the distance between the collisions is small, these latter are no longer independent; the cascade, which then has to be considered as a whole, perturbs and locates, in the irradiated solid , a zone which has been named a 'displacement zone'. It is shown that the proportion of displacement zones increases with increasing atom size (high atomic number Z), with decreasing atomic distance D in the substance considered and with decreasing energy of the ion undergoing the slowing down process (although always remaining above a few hundred eV). The proportions obtained are higher than those corresponding to the calculations of J. A. Brinkman [3]. An interatomic potential required for this work has also been determined. (author) [French] On sait qu'une particule chargee (ions, atomes primaires, etc...) en mouvement dans un solide se ralentit, avec eventuellement deplacement en cascade d'atomes du solide. On etudie ici dans quelle proportion, en fonction de l'energie de la particule chargee initiale, la cascade est constituee, ou non, de 'chocs independants'. Lorsque la distance entre chocs est petite, ceux-ci ne sont plus independants; la cascade, qui doit alors etre consideree dans son ensemble, perturbe et definit dans le solide irradie, une zone qu'on a appele zone de deplacements. On montre que la proportion de zones de deplacements est d'autant plus grande que les atomes sont gros (nombre atomique Z grand), que la distance interatomique D est petite dans le corps considere, et que l'energie de l'ion en ralentissement est petite (tout en restant superieure a quelques centaines d'eV). Les proportions obtenues sont superieures a celles qui

  13. Magnetic properties of point defects in proton irradiated diamond

    Energy Technology Data Exchange (ETDEWEB)

    Makgato, T.N., E-mail: Thuto.Makgato@students.wits.ac.za [School of Physics, University of the Witwatersrand, Johannesburg 2050 (South Africa); Sideras-Haddad, E. [School of Physics, University of the Witwatersrand, Johannesburg 2050 (South Africa); Center of Excellence in Strong Materials, Physics Building, University of the Witwatersrand, Johannesburg 2050 (South Africa); Ramos, M.A. [CMAM, Centro de Micro-Analisis de Materiales, Universidad Autónoma de Madrid, C/Faraday 3, Campus de Cantoblanco, E-28049 Madrid (Spain); Departamento de Fisica de la Materia Condensada, Condensed Matter Physics Center (IFIMAC) and Instituto Nicolás Cabrera, Universidad Autónoma de Madrid, 28049 Madrid (Spain); García-Hernández, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, E-28049 Madrid (Spain); Climent-Font, A.; Zucchiatti, A.; Muñoz-Martin, A. [CMAM, Centro de Micro-Analisis de Materiales, Universidad Autónoma de Madrid, C/Faraday 3, Campus de Cantoblanco, E-28049 Madrid (Spain); Shrivastava, S. [School of Physics, University of the Witwatersrand, Johannesburg 2050 (South Africa); Erasmus, R. [School of Physics, University of the Witwatersrand, Johannesburg 2050 (South Africa); Center of Excellence in Strong Materials, Physics Building, University of the Witwatersrand, Johannesburg 2050 (South Africa)

    2016-09-01

    We investigate the magnetic properties of ultra-pure type-IIa diamond following irradiation with proton beams of ≈1–2 MeV energy. SQUID magnetometry indicate the formation of Curie type paramagnetism according to the Curie law. Raman and Photoluminescence spectroscopy measurements show that the primary structural features created by proton irradiation are the centers: GR1, ND1, TR12 and 3H. The Stopping and Range of Ions in Matter (SRIM) Monte Carlo simulations together with SQUID observations show a strong correlation between vacancy production, proton fluence and the paramagnetic factor. At an average surface vacancy spacing of ≈1–1.6 nm and bulk (peak) vacancy spacing of ≈0.3-0.5 nm Curie paramagnetism is induced by formation of ND1 centres with an effective magnetic moment μ{sub eff}~(0.1–0.2)μ{sub B}. No evidence of long range magnetic ordering is observed in the temperature range 4.2-300 K. - Highlights: • Proton macro-irradiation of pure diamond creates fluence dependent paramagnetism. • The effective magnetic moment is found to be in the range μ{sub eff}~(0.1–0.2)μ{sub B}. • No evidence of long range magnetic ordering is observed.

  14. Magnetic properties of point defects in proton irradiated diamond

    International Nuclear Information System (INIS)

    Makgato, T.N.; Sideras-Haddad, E.; Ramos, M.A.; García-Hernández, M.; Climent-Font, A.; Zucchiatti, A.; Muñoz-Martin, A.; Shrivastava, S.; Erasmus, R.

    2016-01-01

    We investigate the magnetic properties of ultra-pure type-IIa diamond following irradiation with proton beams of ≈1–2 MeV energy. SQUID magnetometry indicate the formation of Curie type paramagnetism according to the Curie law. Raman and Photoluminescence spectroscopy measurements show that the primary structural features created by proton irradiation are the centers: GR1, ND1, TR12 and 3H. The Stopping and Range of Ions in Matter (SRIM) Monte Carlo simulations together with SQUID observations show a strong correlation between vacancy production, proton fluence and the paramagnetic factor. At an average surface vacancy spacing of ≈1–1.6 nm and bulk (peak) vacancy spacing of ≈0.3-0.5 nm Curie paramagnetism is induced by formation of ND1 centres with an effective magnetic moment μ eff ~(0.1–0.2)μ B . No evidence of long range magnetic ordering is observed in the temperature range 4.2-300 K. - Highlights: • Proton macro-irradiation of pure diamond creates fluence dependent paramagnetism. • The effective magnetic moment is found to be in the range μ eff ~(0.1–0.2)μ B . • No evidence of long range magnetic ordering is observed.

  15. Effect of 200 keV proton irradiation on the properties of methyl silicone rubber

    International Nuclear Information System (INIS)

    Zhang Lixin; Xu Zhou; Wei Qiang; He Shiyu

    2006-01-01

    The effects of 200 keV proton irradiation on methyl silicone rubber were studied. The changes in surface morphology, mechanical properties, cross-linking density, glass transition temperature, infrared attenuated total reflection spectrum and mass spectrum indicated that, at lower fluence, the proton irradiation induced cross-linking, resulting in an increase in tensile strength and hardness of the methyl silicone rubber. However, at higher proton fluence, radiation-induced degradation, which decreased the tensile strength and hardness, became dominant. A macromolecular-network destruction model for silicone rubber irradiated with protons was proposed

  16. Effects of proton irradiation on electronic structure of NdFeB permanent magnets

    Energy Technology Data Exchange (ETDEWEB)

    Yang, L. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Zhen, L. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)], E-mail: lzhen@hit.edu.cn; Xu, C.Y.; Sun, X.Y.; Shao, W.Z. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2009-09-15

    Effects of proton irradiation on electronic structure and atomic local structure of N35EH-type NdFeB permanent magnet were investigated by soft X-ray absorption spectrometry and Moessbauer spectrometry. The local coordination environment of Fe atoms changes after proton irradiation, and the average hyperfine field H{sub in} of the magnets decreases from 288.4 to 286.9 kOe. The effects of irradiation on Fe atoms local environment at different lattice sites are different. The near edge structure of Fe L{sub 3} edge is changed, indicating the density of unoccupied state of Fe 3d electrons increases after proton irradiation.

  17. 380 keV proton irradiation effects on photoluminescence of Eu-doped GaN

    International Nuclear Information System (INIS)

    Okada, Hiroshi; Nakanishi, Yasuo; Wakahara, Akihiro; Yoshida, Akira; Ohshima, Takeshi

    2008-01-01

    The effect of 380 keV proton irradiation on the photoluminescence (PL) properties has been investigated for undoped and Eu-doped GaN. As the proton irradiation exceeds 1x10 13 cm -2 , a drastic decrease of PL intensity of the near band-edge emission of undoped GaN was observed. On the other hand, for Eu-doped GaN, the PL emission corresponding to the 5 D 0 → 7 F 2 transition in Eu 3+ kept the initial PL intensity after the proton irradiation up to 1x10 14 cm -2 . Present results, together with our previous report on electron irradiation results, suggest that Eu-doped GaN is a strong candidate for light emitting devices in high irradiation environment

  18. HTB140 melanoma cells under proton irradiation and/or alkylating agents

    Science.gov (United States)

    Korićanac, L.; Petrović, I.; Privitera, G.; Cuttone, G.; Ristić-Fira, A.

    2007-09-01

    Chemoresistance is a major problem in the treatment of malignant melanoma. The mainstay of treatment for melanoma is the DNA-alkylating agent dacarbazine (DTIC). Fotemustine (FM), a member of the chloroethylnitrosourea group of alkylating agents, has also demonstrated significant antitumor effects in malignant melanoma. However, the intrinsic and acquired resistance of melanoma limits the clinical application of these drugs. Melanomas are also extremely radioresistant. With the objective of enhancing growth inhibition of melanoma cells, combined treatments of FM or DTIC with proton irradiation have been investigated. These effects were studied on HTB140 melanoma cell viability and proliferation. Cells exposed to treatment with FM and protons have shown inhibition of cell growth and significant reduction of proliferation capacity compared to single irradiation or drug treatment. Treatment with DTIC and protons has shown improved growth inhibition compared to appropriate single drug treatment, while the effects of single proton irradiation have been the most pronounced.

  19. Anomalous effects in silicon solar cell irradiated by 1-MeV protons

    Science.gov (United States)

    Kachare, R.; Anspaugh, B. E.

    1989-01-01

    Several silicon solar cells having thicknesses of approximately 63 microns, with and without back-surface fields (BSF), were irradiated with 1-MeV protons having fluences between 10 to the 10th and 10 to the 12th sq cm. The irradiations were performed using both normal and isotropic incidence on the rear surfaces of the cells. It was observed that after irradiation with fluences greater than 10 to the 11th protons/sq cm, all BSF cells degraded at a faster rate than cells without BSF. The irradiation results are analyzed using a model in which irradiation-induced defects in the BSF region are taken into account. Tentatively, it is concluded that an increase in defect density due to the formation of aluminum and proton complexes in BSF cells is responsible for the higher-power loss in the BSF cells compared to the non-BSF cells.

  20. Decoration of dislocations by proton irradiation of halite

    International Nuclear Information System (INIS)

    Bird, J.R.; Rose, A.; Wilkins, R.W.T.

    1981-01-01

    Proton irradiation of halite (NaCl) at temperatures in the range 150-220 0 C produces a variety of colours from yellow/brown through blue to violet/red. Under suitable conditions, colour bands are formed which decorate dislocations and colour other crystal features. One beam line of the Lucas Heights 3 MV Van de Graaff accelerator has been adapted to permit the measurement of optical absorption spectra during proton irradiation of heated crystals. The results show that colour centre formation is a more complex process than has been previously reported, even for synthetic NaCl crystals. The dependence of absorption at various wavelengths on dose, dose rate, temperature, strain and exposure to light is being used to study the different quasi-equilibrium concentrations of colour centres involved in the decoration process. Proton induced X-ray measurements provide information on the presence of impurities which can have an important influence on colour centre formation. (orig.)

  1. Proton irradiation effects of amorphous silicon solar cell for solar power satellite

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Yousuke; Oshima, Takeshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Sasaki, Susumu; Kuroda, Hideo; Ushirokawa, Akio

    1997-03-01

    Flexible amorphous silicon(fa-Si) solar cell module, a thin film type, is regarded as a realistic power generator for solar power satellite. The radiation resistance of fa-Si cells was investigated by the irradiations of 3,4 and 10 MeV protons. The hydrogen gas treatment of the irradiated fa-Si cells was also studied. The fa-Si cell shows high radiation resistance for proton irradiations, compared with a crystalline silicon solar cell. (author)

  2. Effects of fotemustine or dacarbasine on a melanoma cell line pretreated with therapeutic proton irradiation

    Directory of Open Access Journals (Sweden)

    Privitera Giuseppe

    2009-04-01

    Full Text Available Abstract Background Considering that HTB140 melanoma cells have shown a poor response to either protons or alkylating agents, the effects of a combined use of these agents have been analysed. Methods Cells were irradiated in the middle of the therapeutic 62 MeV proton spread out Bragg peak (SOBP. Irradiation doses were 12 or 16 Gy and are those frequently used in proton therapy. Four days after irradiation cells were treated with fotemustine (FM or dacarbazine (DTIC. Drug concentrations were 100 and 250 μM, values close to those that produce 50% of growth inhibition. Cell viability, proliferation, survival and cell cycle distribution were assessed 7 days after irradiation that corresponds to more than six doubling times of HTB140 cells. In this way incubation periods providing the best single effects of drugs (3 days and protons (7 days coincided at the same time. Results Single proton irradiations have reduced the number of cells to ~50%. FM caused stronger cell inactivation due to its high toxicity, while the effectiveness of DTIC, that was important at short term, almost vanished with the incubation of 7 days. Cellular mechanisms triggered by proton irradiation differently influenced the final effects of combined treatments. Combination of protons and FM did not improve cell inactivation level achieved by single treatments. A low efficiency of the single DTIC treatment was overcome when DTIC was introduced following proton irradiation, giving better inhibitory effects with respect to the single treatments. Most of the analysed cells were in G1/S phase, viable, active and able to replicate DNA. Conclusion The obtained results are the consequence of a high resistance of HTB140 melanoma cells to protons and/or drugs. The inactivation level of the HTB140 human melanoma cells after protons, FM or DTIC treatments was not enhanced by their combined application.

  3. ASTRO-H CdTe detectors proton irradiation at PIF

    International Nuclear Information System (INIS)

    Limousin, O.; Renaud, D.; Horeau, B.; Dubos, S.; Laurent, P.; Lebrun, F.; Chipaux, R.; Boatella Polo, C.; Marcinkowski, R.; Kawaharada, M.; Watanabe, S.; Ohta, M.; Sato, G.; Takahashi, T.

    2015-01-01

    Asbstract: The French Atomic Energy Commission (CEA), with the support of the European Space Agency (ESA), is partner of the Soft Gamma-Ray Detector (SGD) and the Hard X-ray Imager (HXI) onboard the 6th Japanese X-ray scientific satellite ASTRO-H (JAXA) initiated by the Institute of Space and Astronautical Science (ISAS). Both scientific instruments, one hosting a series of Compton Gamma Cameras and the other being a focal plane of a grazing incidence mirror telescope in the hard X-ray domain, are equipped with Cadmium Telluride based detectors. ASTRO-H will be operated in a Low Earth Orbit with a 31° inclination at ~550 km altitude, thus passing daily through the South Atlantic Anomaly radiation belt, a specially harsh environment where the detectors are suffering the effect of the interaction with trapped high energy protons. As CdTe detector performance might be affected by the irradiation, we investigate the effect of the accumulated proton fluence on their spectral response. To do so, we have characterized and irradiated representative samples of SGD and HXI detector under different conditions. The detectors in question, from ACRORAD, are single-pixels having a size of 2 mm by 2 mm and 750 µm thick. The Schottky contact is either made of an Indium or Aluminum for SGD and HXI respectively. We ran the irradiation test campaign at the Proton Irradiation Facility (PIF) at PSI, and ESA approved equipment to evaluate the radiation hardness of flight hardware. We simulated the proton flux expected on the sensors over the entire mission, and secondary neutrons flux due to primary proton interactions into the surrounding BGO active shielding. We eventually characterized the detector response evolution, emphasizing each detector spectral response as well as its stability by studying the so-called Polarization effect. The latter is provoking a spectral response degradation against time as a charge accumulation process occurs in Schottky type CdTe sensors. In this paper

  4. Efficiency of respiratory-gated delivery of synchrotron-based pulsed proton irradiation

    International Nuclear Information System (INIS)

    Tsunashima, Yoshikazu; Vedam, Sastry; Dong, Lei; Bues, Martin; Balter, Peter; Smith, Alfred; Mohan, Radhe; Umezawa, Masumi; Sakae, Takeji

    2008-01-01

    Significant differences exist in respiratory-gated proton beam delivery with a synchrotron-based accelerator system when compared to photon therapy with a conventional linear accelerator. Delivery of protons with a synchrotron accelerator is governed by a magnet excitation cycle pattern. Optimal synchronization of the magnet excitation cycle pattern with the respiratory motion pattern is critical to the efficiency of respiratory-gated proton delivery. There has been little systematic analysis to optimize the accelerator's operational parameters to improve gated treatment efficiency. The goal of this study was to estimate the overall efficiency of respiratory-gated synchrotron-based proton irradiation through realistic simulation. Using 62 respiratory motion traces from 38 patients, we simulated respiratory gating for duty cycles of 30%, 20% and 10% around peak exhalation for various fixed and variable magnet excitation patterns. In each case, the time required to deliver 100 monitor units in both non-gated and gated irradiation scenarios was determined. Based on results from this study, the minimum time required to deliver 100 MU was 1.1 min for non-gated irradiation. For respiratory-gated delivery at a 30% duty cycle around peak exhalation, corresponding average delivery times were typically three times longer with a fixed magnet excitation cycle pattern. However, when a variable excitation cycle was allowed in synchrony with the patient's respiratory cycle, the treatment time only doubled. Thus, respiratory-gated delivery of synchrotron-based pulsed proton irradiation is feasible and more efficient when a variable magnet excitation cycle pattern is used

  5. The martensitic transformation of Ti–Ni shape memory thin films under proton irradiation

    International Nuclear Information System (INIS)

    Gao, Z.Y.; Wang, H.Z.; Zhu, Y.Y.; Meng, X.L.; Cai, W.

    2015-01-01

    The martensitic transformation behavior of a Ti–Ni alloy irradiated by proton with different doses has been investigated. It is found that the samples irradiated by 150 keV protons have a two-step phase transformation during heating and only one-step transformation during cooling. The exothermic peak at higher temperature disappears during the following thermal cycling. A model based on the stress-assisted martensitic transformation was established by the Transport of Ions in Matter (TRIM) calculations in order to explain the transformation behavior. - Highlights: • Martensitic transformation behavior of TiNi alloy under proton irradiation • Two-step transformation appears upon heating for a sample irradiated at 150 keV. • One-step transformation appears upon cooling for a sample irradiated at 150 keV. • In the following thermal cycling, the higher temperature exothermic peak vanishes

  6. Radiation stability of proton irradiated zirconium carbide

    International Nuclear Information System (INIS)

    Yang, Yong; Dickerson, Clayton A.; Allen, Todd R.

    2009-01-01

    The use of zirconium carbide (ZrC) is being considered for the deep burn (DB)-TRISO fuel as a replacement for the silicon carbide coating. The radiation stability of ZrC was studied using 2.6 MeV protons, across the irradiation temperature range from 600 to 900degC and to doses up to 1.75 dpa. The microstructural characterization shows that the irradiated microstructure is comprised of a high density of nanometer-sized dislocation loops, while no irradiation induced amorphization or voids are observed. The lattice expansion induced by point defects is found to increase as the dose increases for the samples irradiated at 600 and 800degC, while for the 900degC irradiation, a slight lattice contraction is observed. The radiation hardening is also quantified using a micro indentation technique for the temperature and doses studies. (author)

  7. High-energy proton irradiation of C57Bl6 mice under hindlimb unloading

    Science.gov (United States)

    Mendonca, Marc; Todd, Paul; Orschell, Christie; Chin-Sinex, Helen; Farr, Jonathan; Klein, Susan; Sokol, Paul

    2012-07-01

    Solar proton events (SPEs) pose substantial risk for crewmembers on deep space missions. It has been shown that low gravity and ionizing radiation both produce transient anemia and immunodeficiencies. We utilized the C57Bl/6 based hindlimb suspension model to investigate the consequences of hindlimb-unloading induced immune suppression on the sensitivity to whole body irradiation with modulated 208 MeV protons. Eight-week old C57Bl/6 female mice were conditioned by hindlimb-unloading. Serial CBC and hematocrit assays by HEMAVET were accumulated for the hindlimb-unloaded mice and parallel control animals subjected to identical conditions without unloading. One week of hindlimb-unloading resulted in a persistent, statistically significant 10% reduction in RBC count and a persistent, statistically significant 35% drop in lymphocyte count. This inhibition is consistent with published observations of low Earth orbit flown mice and with crewmember blood analyses. In our experiments the cell count suppression was sustained for the entire six-week period of observation and persisted for at least 7 days beyond the period of active hindlimb-unloading. C57Bl/6 mice were also irradiated with 208 MeV Spread Out Bragg Peak (SOBP) protons at the Midwest Proton Radiotherapy Institute at the Indiana University Cyclotron Facility. We found that at 8.5 Gy hindlimb-unloaded mice were significantly more radiation sensitive with 35 lethalities out of 51 mice versus 15 out of 45 control (non-suspended) mice within 30 days of receiving 8.5 Gy of SOBP protons (p =0.001). Both control and hindlimb-unloaded stocktickerCBC analyses of 8.5 Gy proton irradiated and control mice by HEMAVET demonstrated severe reductions in WBC counts (Lymphocytes and PMNs) by day 2 post-irradiation, followed a week to ten days later by reductions in platelets, and then reductions in RBCs about 2 weeks post-irradiation. Recovery of all blood components commenced by three weeks post-irradiation. CBC analyses of 8

  8. Characterizations of Proton-irradiated wide bandgap semiconductor devices

    International Nuclear Information System (INIS)

    Kim, J. H.; Kim, H. R.; Ahn, J. H.

    2008-04-01

    Current-voltages were compared before and after proton irradiation. As expected from simulation results, 5keV protons severely damaged the transistors' performance compared to 25MeV protons. Also, the effects of both lower and higher fluencies were compared. Source-Drain currents were dramatically decreased under higher fluency. At the highest dose of 2x10 16 protons/cm 2 there was a decrease of 43% in IDS and a 29% decrease in gm. The data is consistent with the introduction of defect centers in the HEMT structure by the high energy protons leading to a reduction in carrier concentration and mobility in the 2- dimensional electron gas channel due to the extremely thin 2DEG and the high displacement threshold energy, AlGaN/GaN HEMT has great potential for applications in earth orbit

  9. Production of fast switching power thyristors by proton irradiation

    International Nuclear Information System (INIS)

    Sawko, D.C.; Bartko, J.

    1983-01-01

    There are several techniques currently employed by various manufacturers in the fabrication of fast switching power thyristors. Gold doping and irradiation by electron beams are among the more common ones. In all cases, the fast switching capability results from a reduction of the minority carrier lifetime of the host material by the introduction of carrier traps or recombination centers. However, accompanying this beneficial reduction in switching speed is a deleterious increase in forward voltage drop which also results from the introduction of carrier traps. Methods which minimize the voltage drop increase as the switching speed is reduced are highly desirable. One such method would achieve this by introducing the traps or recombination centers into well defined narrow regions where they will be more effective in reducing the switching speed than in increasing the forward voltage drop. Because the proton range-energy relationship in materials is relatively well defined and the lifetime reducing displacements occur near the end of their ranges, the lifetime in silicon can be reduced where desired by the precise control of proton energy. Dual energy proton beams from a tandem Van de Graaff accelerator were used in the experiments to determine whether proton beam irradiations offer advantages over other techniques. This was the subject of the present work. The results indicate that this is the preferred technique for reproducibly and rapidly processing fast switching thyristors with superior characteristics. The experimental procedure is discussed and comparisons are made with electron and neutron irradiated thyristors

  10. Nano-scale chemical evolution in a proton-and neutron-irradiated Zr alloy

    Energy Technology Data Exchange (ETDEWEB)

    Harte, Allan, E-mail: allan.harte@manchester.ac.uk [The University of Manchester, Oxford Road, Manchester, M13 9PL (United Kingdom); Topping, M.; Frankel, P. [The University of Manchester, Oxford Road, Manchester, M13 9PL (United Kingdom); Jädernäs, D. [Studsvik Nuclear AB, SE 611 82, Nyköping (Sweden); Romero, J. [Westinghouse Electric Company, Columbia, SC (United States); Hallstadius, L. [Westinghouse Electric Sweden AB, SE 72163 Västerås (Sweden); Darby, E.C. [Rolls Royce Plc., Nuclear Materials, Derby (United Kingdom); Preuss, M. [The University of Manchester, Oxford Road, Manchester, M13 9PL (United Kingdom)

    2017-04-15

    Proton-and neutron-irradiated Zircaloy-2 are compared in terms of the nano-scale chemical evolution within second phase particles (SPPs) Zr(Fe,Cr){sub 2} and Zr{sub 2}(Fe,Ni). This is accomplished through ultra-high spatial resolution scanning transmission electron microscopy and the use of energy-dispersive X-ray spectroscopic methods. Fe-depletion is observed from both SPP types after irradiation with both irradiative species, but is heterogeneous in the case of Zr(Fe,Cr){sub 2}, predominantly from the edge region, and homogeneously in the case of Zr{sub 2}(Fe,Ni). Further, there is evidence of a delay in the dissolution of the Zr{sub 2}(Fe,Ni) SPP with respect to the Zr(Fe,Cr){sub 2}. As such, SPP dissolution results in matrix supersaturation with solute under both irradiative species and proton irradiation is considered well suited to emulate the effects of neutron irradiation in this context. The mechanisms of solute redistribution processes from SPPs and the consequences for irradiation-induced growth phenomena are discussed. - Highlights: •Protons emulate the effects of neutron irradiation in the evolution of chemistry and morphology of second phase particles. •Detailed energy-dispersive X-ray spectroscopy reveals heterogeneity in Zr-Fe-Cr SPPs both before and after irradiation. •Zr-Fe-Ni SPPs are delayed in irradiation-induced dissolution due to their better self-solubility with respect to Zr-Fe-Cr.

  11. The semiconductor doping with radiation defects via proton and alpha-particle irradiation. Review

    CERN Document Server

    Kozlov, V A

    2001-01-01

    Paper presents an analytical review devoted to semiconductor doping with radiation defects resulted from irradiation by light ions, in particular, by protons and alpha-particles. One studies formation of radiation defects in silicon, gallium arsenide and indium phosphide under light ion irradiation. One analyzes effect of proton and alpha-particle irradiation on electric conductivity of the above-listed semiconducting materials. Semiconductor doping with radiation defects under light ion irradiation enables to control their electrophysical properties and to design high-speed opto-, micro- and nanoelectronic devices on their basis

  12. Effects of High-Energy Proton-Beam Irradiation on the Magnetic Properties of ZnO Nanorods

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Kue; Kwon, Hyeok-Jung; Cho, Yong Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    There are still many problem for the application due to its unstable magnetism state and too small magnetization values. Here we investigate magnetic properties of ZnO nanorods after high-energy proton-beam irradiation. Electron spin resonance (ESR) measurement on temperature was made to identify intrinsic or extrinsic defects as well as to observe magnetic ordering after irradiation. Understanding the effects of proton beam irradiation on magnetic behavior may help to shed light on the mechanism responsible for the magnetic ordering in this material. We have investigated proton-beam irradiation effects on the magnetic properties of ZnO nanorods. After irradiation a broad ESR line is observed, indicating emergence of ferromagnetic ordering up to room temperature. In M-H curve, stronger coercive field is observed after irradiation.

  13. Single crystal growth of 67%BiFeO3-33%BaTiO3 solution by the floating zone method

    Science.gov (United States)

    Rong, Y.; Zheng, H.; Krogstad, M. J.; Mitchell, J. F.; Phelan, D.

    2018-01-01

    The growth conditions and the resultant grain morphologies and phase purities from floating-zone growth of 67%BiFeO3-33%BaTiO3 (BF-33BT) single crystals are reported. We find two formidable challenges for the growth. First, a low-melting point constituent leads to a pre-melt zone in the feed-rod that adversely affects growth stability. Second, constitutional super-cooling (CSC), which was found to lead to dendritic and columnar features in the grain morphology, necessitates slow traveling rates during growth. Both challenges were addressed by modifications to the floating-zone furnace that steepened the temperature gradient at the melt-solid interfaces. Slow growth was also required to counter the effects of CSC. Single crystals with typical dimensions of hundreds of microns have been obtained which possess high quality and are suitable for detailed structural studies.

  14. Single crystal growth of 67%BiFeO 3 -33%BaTiO 3 solution by the floating zone method

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Y.; Zheng, H.; Krogstad, M. J.; Mitchell, J. F.; Phelan, D.

    2018-01-01

    The growth conditions and the resultant grain morphologies and phase purities from floating-zone growth of 67%BiFeO3-33%BaTiO3 (BF-33BT) single crystals are reported. We find two formidable challenges for the growth. First, a low-melting point constituent leads to a pre-melt zone in the feed-rod that adversely affects growth stability. Second, constitutional super-cooling (CSC), which was found to lead to dendritic and columnar features in the grain morphology, necessitates slow traveling rates during growth. Both challenges were addressed by modifications to the floating-zone furnace that steepened the temperature gradient at the melt-solid interfaces. Slow growth was also required to counter the effects of CSC. Single crystals with typical dimensions of hundreds of microns have been obtained which possess high quality and are suitable for detailed structural studies.

  15. Analysis of Giant-nucleated Cell Formation Following X-ray and Proton Irradiations

    Science.gov (United States)

    Almahwasi, Ashraf Abdu

    Radiation-induced genetic instability has been observed in survivors of irradiated cancerous and normal cells in vitro and in vivo and has been determined in different forms, such as delayed cell death, chromosomal aberration or mutation. A well defined and characterized normal human-diploid AG1522 fibroblast cell line was used to study giant-nucleated cell (GCs) formation as the ultimate endpoint of this research. The average nuclear cross-sectional areas of the AG1522 cells were measured in mum2. The doubling time required by the AG1522 cells to divide was measured. The potential toxicity of the Hoechst dye at a working concentration on the live AG1522 cells was assessed. The yield of giant cells was determined at 7, 14 and 21 days after exposure to equivalent clinical doses of 0.2, 1 or 2 Gy of X-ray or proton irradiation. Significant differences were found to exist between X-ray or proton irradiation when compared with sham-irradiated control populations. The frequency of GCs induced by X-rays was also compared to those formed in proton irradiated cultures. The results confirm that 1 Gy X-rays are shown to induce higher rates of mitotically arrested GCs, increasing continually over time up to 21 days post-irradiation. The yield of GCs was significantly greater (10%) compared to those formed in proton populations (2%) 21 days postirradiation. The GCs can undergo a prolonged mitotic arrest that significantly increases the length of cell cycle. The arrest of GCs at the mitotic phase for longer periods of time might be indicative of a strategy for cell survival, as it increases the time available for DNA repair and enables an alternative route to division for the cells. However, the reduction in their formation 21 days after both types of radiation might favour GCs formation, ultimately contributing to carcinogenesis or cancer therapy resistance. The X-ray experiments revealed a dose-dependent increase in the GCs up to 14 days after irradiation. Although the proton

  16. Formation of Cavities at and Away from Grain Boundaries during 600 MeV Proton Irradiation

    DEFF Research Database (Denmark)

    Singh, Bachu Narain; Leffers, Torben; Green, W. V.

    1982-01-01

    High-purity aluminium (99.9999%) was irradiated with 600 MeV protons at the Swiss Institute for Nuclear Research (SIN) with a damage rate of 3,5 x 10^-6 dpa/s. Irradiation with 600 MeV protons produces helium, hydrogen, and other impurities through mutational reactions. The irradiation experiment...

  17. Analytical dose modeling for preclinical proton irradiation of millimetric targets.

    Science.gov (United States)

    Vanstalle, Marie; Constanzo, Julie; Karakaya, Yusuf; Finck, Christian; Rousseau, Marc; Brasse, David

    2018-01-01

    Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological effectiveness of proton radiation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the specific constraints imposed by the small dimensions of the irradiated areas. The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was validated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modeling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irradiated with a 24-MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commission on Radiation Units and Measurements for all tested configurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a significant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Good dose accuracy for millimetric tumors is achieved with the analytical calculation used in this work. These volume sizes are typical in mouse

  18. Comparison of relevant parameters of multi-pixel sensors for tracker detectors after irradiation with high proton and neutron fluences

    International Nuclear Information System (INIS)

    Bergholz, Matthias

    2016-03-01

    The further increase of the luminosity of the Large Hadron Collider (LHC) at CERN requires new sensors for the tracking detector of the Compact Muon Soleniod (CMS) experiment. These sensors must be more radiation hard and of a finer granularity to lower the occupancy. In addition the new sensor modules must have a lower material budget and have to be self triggering. Sensor prototypes, the so called ''MPix''-sensors, produced on different materials were investigated for their radiation hardness. These sensors were fully characterized before and after irradiation. Of particular interest was the comparison of different bias methods, different materials and the influence of various geometries. The degeneration rate differs for the different sensor materials. The increase of the dark current of Float-Zone-Silicon is stronger for thicker sensors and less than for Magnetic-Czochralski-Silicon sensors. Both tested bias structures are damaged by the irradiation. The poly silicon resistance increases after irradiation by fifty percent. The Punch-Through-Structure is more effected by irradiation. The punch-through voltage increase by a factor of two. Due to the higher pixel current, the working point of the sensor is shifted to smaller differential resistances.

  19. Parameterisation of radiation effects on CVD diamond for proton irradiation

    International Nuclear Information System (INIS)

    Hartjes, F.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.

    1999-01-01

    The paper reviews measurements of the radiation hardness of CVD diamond for 24 GeV/c proton irradiation at fluences up to 5 * 10 15 protons/cm 2 . The results not only show radiation damage but also an annealing effect that is dominant at levels around 10 15 protons/cm 2 . A model describing both effects is introduced, enabling a prediction of the distribution curve of the charge signal for other levels

  20. Compaction of PDMS due to proton beam irradiation

    International Nuclear Information System (INIS)

    Szilasi, S.Z.; Huszank, R.; Rajta, I.; Kokavecz, J.

    2011-01-01

    Complete text of publication follows. This work is about the detailed investigation of the changes of the surface topography, the degree of compaction/shrinkage and its relation to the irradiation fluence and the structure spacing in poly(dimethylsiloxane) (PDMS) patterned with 2 MeV proton microbeam. Sylgard 184 kit (Dow-Corning) was used to create the PDMS samples. The density of the PDMS samples was determined with pycnometer. The penetration depth for 2 MeV protons is ∼85 μm, the PDMS layer was ∼95 μm thick, so the incident protons stop in the PDMS, they do not reach the substrate. The irradiations have been performed at the nuclear microprobe facility at ATOMKI. The irradiated periodic structures consisted of parallel lines with different widths and spacing. To achieve different degrees of compaction, each structure was irradiated with five different fluences. The surface topography, the phase modification of the surface, and the connection between them were revealed using an atomic force microscope (AFM PSIA XE 100). The shrinkage data were obtained from the topography images. The structures with different line widths and spacing show different degrees of compaction as a function of irradiation fluence. By plotting them in the same graph (Fig. 1) it is clearly seen that the degree of compaction depends on both the irradiation fluence and the distance of the structures. The fluence dependence of the compaction can be explained with the chemical changes of PDMS. When an energetic ion penetrates through the material it scissions the polymer chain, whereupon among other things volatile products form. In the case of PDMS, these are mainly hydrogen, methane and ethane gases that can be released from PDMS. The irradiated volume shrinks due to significant structural change during which silicate derivatives (SiO x ) are formed. The phase change and the corresponding surface topography was compared and studied at all applied irradiation fluences. It was concluded

  1. Degradation of SiGe devices by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohyama, Hidenori; Hayama, Kiyoteru [Kumamoto National Coll. of Technology, Nishigoshi (Japan); Vanhellemont, J; Takami, Yasukiyo; Sunaga, Hiromi; Nashiyama, Isamu; Uwatoko, Yoshiya; Poortmans, J; Caymax, M

    1997-03-01

    The degradation and recovery behavior of strained Si{sub 1-x}Ge{sub x} diodes and heterojunction bipolar transistors (HBTs) by irradiated by protons are studied. The degradation of device performance and the generation of lattice defects are reported as a function of fluence and germanium content and also compared extensively with previous results obtained on electron and neutron irradiated devices. In order to study the recovery behavior of the irradiated devices, isochronal annealing is performed. The radiation source dependence of the degradation is discussed taking into account the number of knock-on atoms and the nonionizing energy loss (NIEL). (author)

  2. Defect structure in proton-irradiated copper and nickel

    International Nuclear Information System (INIS)

    Tsukuda, Noboru; Ehrhart, P.; Jaeger, W.; Schilling, W.; Dworschak, F.; Gadalla, A.A.

    1987-01-01

    This single crystals of copper or nickel with a thickness of about 10 μm are irradiated with 3 MeV protons at room temperature and the structures of resultant defects are investigated based on measurements of the effects of irradiation on the electrical resistivity, length, lattice constants, x-ray diffraction line profile and electron microscopic observations. The measurements show that the electrical resistivity increases with irradiation dose, while leveling off at high dose due to overlapping of irradiation cascades. The lattice constants decreases, indicating that many vacancies still remain while most of the interstitial stoms are eliminated, absorbed or consumed for dislocation loop formation. The x-ray line profile undergoes broadening, which is the result of dislocation loops, dislocation networks and SFT's introduced by the proton irradiation. Various defects have different effects though they cannot be identified separately from the profile alone. A satellite peak appears at a low angle, which seems to arise from periodic defect structures that are found in electron microscopic observations. In both copper and nickel, such periodic defect structures are seen over a wide range from high to low dose. Defect-free and defect-rich domains (defect walls), 0.5 to several μm in size, are alingned parallel to the {001} plane at intervals of 60 nm. The defect walls, which consist of dislocations, dislocation loops and SFT's, is 20 - 40 nm thick. (Nogami, K.)

  3. Survival of tumor cells after proton irradiation with ultra-high dose rates

    International Nuclear Information System (INIS)

    Auer, Susanne; Hable, Volker; Greubel, Christoph; Drexler, Guido A; Schmid, Thomas E; Belka, Claus; Dollinger, Günther; Friedl, Anna A

    2011-01-01

    Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >10 9 Gy s -1 may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within < 1 ns or 100 ms, respectively. Investigated endpoints were G2 phase cell cycle arrest, apoptosis, and colony formation. At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE) for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD), respectively. At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional) continuous irradiation mode do not differ significantly

  4. Changes of initiation, promotion and metastatic enzyme system in human breast cancer with the proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Y. H.; Kim, S. W.; Lee, K. S.; Mo, J. Y. [Dongguk University, Seoul (Korea, Republic of)

    2010-04-15

    Proton irradiations in the cells were significantly decreased cell viability but increased the QR activity in a dose-dependent manner. Cell viability was 92.3%, 88.4%, 81.8%, 72.4%, 68.9% at doses of 0.5, 2, 8, 16, and 32 Gy, respectively. At doses of 2, 8, 16, and 32 Gy, QR activity was increased 1.27-, 1.31-, 1.45- and 2.08-fold. However, negligible GST activity in the cells was detected and the activity was not changed by proton irradiation. Proton irradiation also increased GSH contents by 1.18- and 1.21-fold at doses of 0.5 and 2 Gy. In contrast, the ODC activity, a key enzyme in polyamine biosynthesis and tumor promotion, was decreased in a dose-dependent manner. We also investigated anti-metastatic effects of proton beam irradiation in breast cancer cells. Invasion and wound healing assay showed that metastatic activities in breast cancer cells were significantly decreased in a dose-dependent manner by proton beam irradiation. In zymography of MMP-9, the activity was slightly diminished. These results suggest that breast cancer chemopreventive potential was increased with proton irradiation by increasing the QR activity and the GSH levels and by inhibiting the ODC activity.

  5. Changes of initiation, promotion and metastatic enzyme system in human breast cancer with the proton irradiation

    International Nuclear Information System (INIS)

    Sohn, Y. H.; Kim, S. W.; Lee, K. S.; Mo, J. Y.

    2010-04-01

    Proton irradiations in the cells were significantly decreased cell viability but increased the QR activity in a dose-dependent manner. Cell viability was 92.3%, 88.4%, 81.8%, 72.4%, 68.9% at doses of 0.5, 2, 8, 16, and 32 Gy, respectively. At doses of 2, 8, 16, and 32 Gy, QR activity was increased 1.27-, 1.31-, 1.45- and 2.08-fold. However, negligible GST activity in the cells was detected and the activity was not changed by proton irradiation. Proton irradiation also increased GSH contents by 1.18- and 1.21-fold at doses of 0.5 and 2 Gy. In contrast, the ODC activity, a key enzyme in polyamine biosynthesis and tumor promotion, was decreased in a dose-dependent manner. We also investigated anti-metastatic effects of proton beam irradiation in breast cancer cells. Invasion and wound healing assay showed that metastatic activities in breast cancer cells were significantly decreased in a dose-dependent manner by proton beam irradiation. In zymography of MMP-9, the activity was slightly diminished. These results suggest that breast cancer chemopreventive potential was increased with proton irradiation by increasing the QR activity and the GSH levels and by inhibiting the ODC activity.

  6. Effect of proton and electron-irradiation intensity on radiation-induced damages in silicon bioolar transistors

    International Nuclear Information System (INIS)

    Bannikov, Yu.A.; Gorin, B.M.; Kozhevnikov, V.P.; Mikhnovich, V.V.; Gusev, L.I.

    1981-01-01

    The increase of radiation-induced damages of bipolar n-p-n transistors 8-12 times with the irradiation intensity decrease by protons from 4.07x1010 to 2.5x107 cm-2 x c-1 has been found experimentally. damages of p-n-p transistors vary in the opposite way - they are decreased 2-3 times with the irradiation intensity decrease within the same limits. the dependence of damages on intansity of proton irradiation occurs at the dose rate by three orders less than it has been observed for electron irradiation. the results obtained are explained by the dependence of radiation defectoformation reactions on charge state of defects with account for the role of formation of disordering regions upon proton irradiation [ru

  7. An overview of the PIREX Proton Irradiation facility and its research program

    Energy Technology Data Exchange (ETDEWEB)

    Victoria, M.; Gavillet, D. [Association EURATOM, Villigen (Switzerland)

    1995-10-01

    The main design characteristics of PIREX (Proton Irradiation Experiment) are described. The facility is installed in the 590 MeV proton beam of the PSI accelerator system. Its main task is the irradiation and testing of fusion reactor candidate materials. Protons of this energy produce simultaneously in the target material displacement damage and impurities, amongst them helium. They can therefore simulate possible synergistic effects between helium and damage that would result from irradiations with the fusion neutrons. The research program being developed includes studies on both materials of technological interest, such as martensitic stainless steels and Mo - based alloys and basic radiation damage research on pure metals. The facility is also being used for actinide transmutation studies, in the so called ATHENA experiment. The main directions of the research program are described and examples of present results are given.

  8. Determination of proton and neutron spectra in the LANSCE spallation irradiation facility

    International Nuclear Information System (INIS)

    James, M.R.; Maloy, S.A.; Sommer, W.F.; Fowler, M.M.; Dry, D.; Ferguson, P.D.; Mueller, G.; Corzine, R.K.

    1999-01-01

    Materials samples were recently irradiated in the Los Alamos Radiation Effects Facility (LASREF) at the Los Alamos Neutron Science Center (LANSCE) to provide data for the Accelerator Production of Tritium (APT) project on the effect of irradiation on the mechanical and physical properties of materials. The targets were configured to expose samples to a variety of radiation environments including, high-energy protons, mixed protons and high-energy neutrons, and low-energy neutrons. The samples were irradiated for approximately six months during a ten month period using an 800 MeV proton beam with a circular Gaussian shape of approximately 2σ = 3.0 cm. At the end of this period, the samples were extracted and tested. Activation foils were also extracted that had been placed in proximity to the materials samples. These were used to quantify the fluences in various locations

  9. Parameterisation of radiation effects on CVD diamond for proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hartjes, F.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P.F.; Manfredotti, C.; Marshall, R.D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L.S.; Palmieri, V.G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M

    1999-08-01

    The paper reviews measurements of the radiation hardness of CVD diamond for 24 GeV/c proton irradiation at fluences up to 5{sup *}10{sup 15} protons/cm{sup 2}. The results not only show radiation damage but also an annealing effect that is dominant at levels around 10{sup 15} protons/cm{sup 2}. A model describing both effects is introduced, enabling a prediction of the distribution curve of the charge signal for other levels.

  10. DNA double strand breaks and Hsp70 expression in proton irradiated living cells

    International Nuclear Information System (INIS)

    Fiedler, Anja; Reinert, Tilo; Tanner, Judith; Butz, Tilman

    2007-01-01

    DNA double strand breaks (DSBs) in living cells can be directly provoked by ionising radiation. DSBs can be visualized by immunostaining the phosphorylated histone γH2AX. Our concern was to test the feasibility of γH2AX staining for a direct visualization of single proton hits. If single protons produce detectable foci, DNA DSBs could be used as 'biological track detectors' for protons. Ionising radiation can also damage proteins indirectly by inducing free radicals. Heat shock proteins (Hsp) help to refold or even degrade the damaged proteins. The level of the most famous heat shock protein Hsp70 is increased by ionising radiation. We investigated the expression of γH2AX and Hsp70 after cross and line patterned irradiation with counted numbers of 2.25 MeV protons on primary human skin fibroblasts. The proton induced DSBs appear more delocalised than it was expected by the ion hit accuracy. Cooling the cells before the irradiation reduces the delocalisation of DNA DSBs, which is probably caused by the reduced diffusion of DNA damaging agents. Proton irradiation seems to provoke protein damages mainly in the cytoplasm indicated by cytoplasmic Hsp70 aggregates. On the contrary, in control heat shocked cells the Hsp70 was predominantly localized in the cell nucleus. However, the irradiated area could not be recognized, all cells on the Si 3 N 4 window showed a homogenous Hsp70 expression pattern

  11. DNA double strand breaks and Hsp70 expression in proton irradiated living cells

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, Anja [Institute for Experimental Physics II, University of Leipzig (Germany) and Faculty of Biology, Pharmacy and Psychology, University of Leipzig (Germany)]. E-mail: afiedler@uni-leipzig.de; Reinert, Tilo [Institute for Experimental Physics II, University of Leipzig (Germany); Tanner, Judith [Clinic and Polyclinic for Radiation Oncology, University of Halle-Wittenberg (Germany); Butz, Tilman [Institute for Experimental Physics II, University of Leipzig (Germany)

    2007-07-15

    DNA double strand breaks (DSBs) in living cells can be directly provoked by ionising radiation. DSBs can be visualized by immunostaining the phosphorylated histone {gamma}H2AX. Our concern was to test the feasibility of {gamma}H2AX staining for a direct visualization of single proton hits. If single protons produce detectable foci, DNA DSBs could be used as 'biological track detectors' for protons. Ionising radiation can also damage proteins indirectly by inducing free radicals. Heat shock proteins (Hsp) help to refold or even degrade the damaged proteins. The level of the most famous heat shock protein Hsp70 is increased by ionising radiation. We investigated the expression of {gamma}H2AX and Hsp70 after cross and line patterned irradiation with counted numbers of 2.25 MeV protons on primary human skin fibroblasts. The proton induced DSBs appear more delocalised than it was expected by the ion hit accuracy. Cooling the cells before the irradiation reduces the delocalisation of DNA DSBs, which is probably caused by the reduced diffusion of DNA damaging agents. Proton irradiation seems to provoke protein damages mainly in the cytoplasm indicated by cytoplasmic Hsp70 aggregates. On the contrary, in control heat shocked cells the Hsp70 was predominantly localized in the cell nucleus. However, the irradiated area could not be recognized, all cells on the Si{sub 3}N{sub 4} window showed a homogenous Hsp70 expression pattern.

  12. Whole body proton irradiation causes acute damage to bone marrow hematopoietic progenitor and stem cells in mice.

    Science.gov (United States)

    Chang, Jianhui; Wang, Yingying; Pathak, Rupak; Sridharan, Vijayalakshmi; Jones, Tamako; Mao, Xiao Wen; Nelson, Gregory; Boerma, Marjan; Hauer-Jensen, Martin; Zhou, Daohong; Shao, Lijian

    2017-12-01

    Exposure to proton irradiation during missions in deep space can lead to bone marrow injury. The acute effects of proton irradiation on hematopoietic stem and progenitor cells remain undefined and thus were investigated. We exposed male C57BL/6 mice to 0.5 and 1.0 Gy proton total body irradiation (proton-TBI, 150 MeV) and examined changes in peripheral blood cells and bone marrow (BM) progenitors and LSK cells 2 weeks after exposure. 1.0 Gy proton-TBI significantly reduced the numbers of peripheral blood cells compared to 0.5 Gy proton-TBI and unirradiated animals, while the numbers of peripheral blood cell counts were comparable between 0.5 Gy proton-TBI and unirradiated mice. The frequencies and numbers of LSK cells and CMPs in BM of 0.5 and 1.0 Gy irradiated mice were decreased in comparison to those of normal controls. LSK cells and CMPs and their progeny exhibited a radiation-induced impairment in clonogenic function. Exposure to 1.0 Gy increased cellular apoptosis but not the production of reactive oxygen species (ROS) in CMPs two weeks after irradiation. LSK cells from irradiated mice exhibited an increase in ROS production and apoptosis. Exposure to proton-TBI can induce acute damage to BM progenitors and LSK cells.

  13. Anti-angiogenic activity in metastasis of human breast cancer cells irradiated by a proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyu-Shik; Shin, Jin-Sun; Nam, Kyung-Soo [Dongguk University, Gyeongju (Korea, Republic of); Shon, Yun-Hee [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2012-07-15

    Angiogenesis is an essential process of metastasis in human breast cancer. We investigated the effects of proton beam irradiation on angiogenic enzyme activities and their expressions in MCF-7 human breast cancer cells. The regulation of angiogenic regulating factors, of transforming growth factor-β (TGF-β) and of vesicular endothelial growth factor (VEGF) expression in breast cancer cells irradiated with a proton beam was studied. Aromatase activity and mRNA expression, which is correlated with metastasis, were significantly decreased by irradiation with a proton beam in a dose-dependent manner. TGF-β and VEGF transcriptions were also diminished by proton beam irradiation. In contrast, transcription of tissue inhibitors of matrix metalloproteinases (TIMPs), also known as biological inhibitors of matrix metalloproteinases (MMPs), was dose-dependently enhanced. Furthermore, an increase in the expression of TIMPs caused the MMP-9 activity to be diminished and the MMP-9 and the MMP-2 expressions to be decreased. These results suggest that inhibition of angiogenesis by proton beam irradiation in breast cancer cells is closely related to inhibitions of aromatase activity and transcription and to down-regulation of TGF-β and VEGF transcription.

  14. Defect recovery in aluminum irradiated with protons at 20 K

    DEFF Research Database (Denmark)

    Linderoth, S.; Rajainmäki, H.; Nieminen, R. M.

    1987-01-01

    Aluminum single crystals have been irradiated with 7.0-MeV protons at 20 K. The irradiation damage and its recovery are studied with positron-lifetime spectroscopy between 20 and 500 K. Stage-I recovery is observed at 40 K. At 240 K, loss of freely migrating vacancies is observed. Hydrogen...

  15. Vacancy-type defects in electron and proton irradiated ZnO and ZnS

    International Nuclear Information System (INIS)

    Brunner, S.; Puff, W.; Logar, B.; Baumann, H.

    1997-01-01

    A study aimed at investigating basic properties of radiation induced effects in ZnO and ZnS has been presented. Positron annihilation experiments (both lifetime and Doppler-broadening measurements) were performed on polycrystalline samples. For ZnO it was found that both electron and proton irradiation caused significant changes in the positron annihilation characteristics and several annealing stages were observed, related to the annealing of variously sized vacancy complexes. The lifetime in defected, proton irradiated polycrystalline ZnS samples, grown by chemical vapour deposition, indicates the formation of large defect complexes. The annealing of proton irradiated ZnS in air at temperatures between 650 C and 750 C leads to significant oxidation and transformation into ZnO. 10 refs, 2 figs, 1 tab

  16. Vacancy-type defects in electron and proton irradiated ZnO and ZnS

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, S.; Puff, W.; Logar, B. [Technische Univ., Graz (Austria). Inst. fuer Kernphysik; Mascher, P. [McMaster Univ., Hamilton, ON (Canada). Dept. of Biology; Balogh, A.G. [Technische Hochschule Darmstadt (Germany); Baumann, H. [Frankfurt Univ. (Germany). Inst. fuer Kernphysik

    1997-10-01

    A study aimed at investigating basic properties of radiation induced effects in ZnO and ZnS has been presented. Positron annihilation experiments (both lifetime and Doppler-broadening measurements) were performed on polycrystalline samples. For ZnO it was found that both electron and proton irradiation caused significant changes in the positron annihilation characteristics and several annealing stages were observed, related to the annealing of variously sized vacancy complexes. The lifetime in defected, proton irradiated polycrystalline ZnS samples, grown by chemical vapour deposition, indicates the formation of large defect complexes. The annealing of proton irradiated ZnS in air at temperatures between 650 C and 750 C leads to significant oxidation and transformation into ZnO. 10 refs, 2 figs, 1 tab.

  17. Persistent changes in neuronal structure and synaptic plasticity caused by proton irradiation.

    Science.gov (United States)

    Parihar, Vipan K; Pasha, Junaid; Tran, Katherine K; Craver, Brianna M; Acharya, Munjal M; Limoli, Charles L

    2015-03-01

    Cranial radiotherapy is used routinely to control the growth of primary and secondary brain tumors, but often results in serious and debilitating cognitive dysfunction. In part due to the beneficial dose depth distributions that may spare normal tissue damage, the use of protons to treat CNS and other tumor types is rapidly gaining popularity. Astronauts exposed to lower doses of protons in the space radiation environment are also at risk for developing adverse CNS complications. To explore the consequences of whole body proton irradiation, mice were subjected to 0.1 and 1 Gy and analyzed for morphometric changes in hippocampal neurons 10 and 30 days following exposure. Significant dose-dependent reductions (~33 %) in dendritic complexity were found, when dendritic length, branching and area were analyzed 30 days after exposure. At equivalent doses and times, significant reductions in the number (~30 %) and density (50-75 %) of dendritic spines along hippocampal neurons of the dentate gyrus were also observed. Immature spines (filopodia, long) exhibited the greatest sensitivity (1.5- to 3-fold) to irradiation, while more mature spines (mushroom) were more resistant to changes over a 1-month post-irradiation timeframe. Irradiated granule cell neurons spanning the subfields of the dentate gyrus showed significant and dose-responsive reductions in synaptophysin expression, while the expression of postsynaptic density protein (PSD-95) was increased significantly. These findings corroborate our past work using photon irradiation, and demonstrate for the first time, dose-responsive changes in dendritic complexity, spine density and morphology and synaptic protein levels following exposure to low-dose whole body proton irradiation.

  18. Scanning of irradiated silicon detectors using $\\alpha$ particles and low energy protons

    CERN Document Server

    Casse, G L; Glaser, M; Kohout, Z; Konícek, J; Lemeilleur, F; Leroy, C; Linhart, V; Mares, J J; Pospísil, S; Roy, P; Sopko, B; Sinor, M; Svejda, J; Vorobel, V; Wilhelm, I

    1999-01-01

    In a spectroscopic study of non-irradiated and proton-irradiated silicon diodes, the detectors were illuminated from the front side and from the rear side by various alpha particle sources (mainly ThC') and by monoenergetic protons with energies from 1.0 to 2.5~MeV. Their response characteristics have been studied as a function of the incoming particle energy and the applied bias voltage. The charge collection efficiency was determined as a function of fluence

  19. Positron annihilation studies on proton irradiated nitrile rubber

    International Nuclear Information System (INIS)

    Ravi Chandran, T.S.G.; Lobo, Blaise; Ranganath, M.R.; Gopal, S.; Sreeramalu, V.

    1996-01-01

    NBR (Nitrile Butadiene Rubber) was irradiated with 4 MeV proton beam from a variable energy cyclotron (VEC) at VEC Centre, Calcutta, to a flux of 10 16 ions/cm 2 , in a vacuum of 10 -9 Torr and was studied through positron lifetime measurements

  20. Studying the destruction of various fluoropolymers caused by gamma - irradiation and MeV protons

    International Nuclear Information System (INIS)

    Allayarov, S.R.; Ol'khov, Yu.A.; Gordon, D.A.; Muntele, C.I.; Muntele, I.C.; Ila, D.; Dixon, D.A.; Kispert, L.D.; Nikolskij, V.G.

    2007-01-01

    While fluoropolymers are normally used as anti-adherent coating, they are intensely investigated for potential use in various radiation dosimeter applications as well as space technology. In order to understand the discrepancy between high chemical and thermal stability and low radiation stability of various fluoropolymers, we are bombarding them with 1 MeV protons to fluences up to 2·10 15 protons/cm 2 as well as subjected some of them to gamma-irradiation by dose of 10 kGy. During bombardment we are monitoring the emission of chemical species with a residual gas analyzer. Gamma-irradiated samples were tested by radio thermoluminescence method. The results we present here are a good indicator that material damage happens much earlier than 2·10 15 protons/cm 2 and that further work should be addressed at much smaller exposures. Radio thermoluminescence also can be used at small doses of irradiation (10-30 kGy). The thermomechanical curve of radiation-free polyvinyledenefluoride (PVDF) is characteristic for topologically di-block amorphous polymer of quasi-crossing structure. In the temperature range of from 173 K up to 228 K polymer is vitrified. The vitrification temperature of PVDF is 228 K. All molecular-relaxation and quantitative characteristics of PVDF were determined before and after its irradiation by protons. Protons caused significant changes in PVDF. From di-block amorphous it transformed in to amorphous-crystalline structure. An appreciable influence of dose at proton irradiation of polymer was revealed both on topological level and on molecular-relaxation one. (authors)

  1. Comparison of the microstructure, deformation and crack initiation behavior of austenitic stainless steel irradiated in-reactor or with protons

    Science.gov (United States)

    Stephenson, Kale J.; Was, Gary S.

    2015-01-01

    The objective of this study was to compare the microstructures, microchemistry, hardening, susceptibility to IASCC initiation, and deformation behavior resulting from proton or reactor irradiation. Two commercial purity and six high purity austenitic stainless steels with various solute element additions were compared. Samples of each alloy were irradiated in the BOR-60 fast reactor at 320 °C to doses between approximately 4 and 12 dpa or by a 3.2 MeV proton beam at 360 °C to a dose of 5.5 dpa. Irradiated microstructures consisted mainly of dislocation loops, which were similar in size but lower in density after proton irradiation. Both irradiation types resulted in the formation of Ni-Si rich precipitates in a high purity alloy with added Si, but several other high purity neutron irradiated alloys showed precipitation that was not observed after proton irradiation, likely due to their higher irradiation dose. Low densities of small voids were observed in several high purity proton irradiated alloys, and even lower densities in neutron irradiated alloys, implying void nucleation was in process. Elemental segregation at grain boundaries was very similar after each irradiation type. Constant extension rate tensile experiments on the alloys in simulated light water reactor environments showed excellent agreement in terms of the relative amounts of intergranular cracking, and an analysis of localized deformation after straining showed a similar response of cracking to surface step height after both irradiation types. Overall, excellent agreement was observed after proton and reactor irradiation, providing additional evidence that proton irradiation is a useful tool for accelerated testing of irradiation effects in austenitic stainless steel.

  2. Tensile properties of several 800 MeV proton-irradiated bcc metals and alloys

    International Nuclear Information System (INIS)

    Brown, R.D.; Wechsler, M.S.; Tschalar, C.

    1987-01-01

    A spallation neutron source for the 600-MeV proton accelerator facility at the Swiss Institute for Nuclear Research (SIN) consists of a vertical cylinder filled with molten Pb-Bi. The proton beam enters the cylinder, passing upward through a window in contact with the Pb-Bi eutectic liquid that must retain reasonable strength and ductility upon irradiation at about 673 K to fluence of about 1 x 10/sup 25/ protons/m/sup 2/. Investigations are underway at the 800-MeV proton accelerator at the Los Alamos Meson Physics Facility (LAMPF) to test the performance of candidate SIN window materials under appropriate conditions of temperature, irradiation, and environment. Based on considerations of chemical compatibility with molten Pb-Bi, as well as interest in identifying fundamental radiation damage mechanisms, Fe, Ta, Fe-2.25Cr-1Mo, and Fe-12Cr-1Mo(HT-9) were chosen as candidate materials. Sheet tensile samples, 0.5-mm thick, of the four materials were fabricated and heat treated. The samples were sealed inside capsules containing Pb-Bi and were proton-irradiated at LAMPF to two fluences, 4.8 and 54 x 10/sup 23/ p/m/sup 2/. The beam current was approximately equal to the 1 mA anticipated for the upgraded SIN accelerator. The power deposited by the proton beam in the capsules was sufficient to maintain sample temperatures of about 673 K. Post-irradiation tensile tests were conducted at room temperature at a strain rate of 9 x 10/sup -4/s/sup -1/. The yield and ultimate strengths increased upon irradiation in all materials, while the ductility decreased, as indicated by the uniform strain. The pure metals, Ta and Fe, exhibited the greatest radiation hardening and embrittlement. The HT-9 alloy showed the smallest changes in strength and ductility. The increase in strength following irradiation is discussed in terms of a dispersed-barrier hardening model, for which the barrier sizes and formation cross sections are calculated

  3. Response of a biological model to a proton beam in vivo

    International Nuclear Information System (INIS)

    Schuff, Juan A.; Burlon, Alejandro A.; Debray, Mario E.; Kesque, Jose M.; Kreiner, Andres J.; Stoliar, Pablo A.; Naab, Fabian; Ozafran, Mabel J.; Vazquez, Monica E.

    2000-01-01

    Wistar rats were locally irradiated with proton beams. By means of a plastic wedge used as an energy degradator of variable thickness, dorsal portions of skin were irradiated at several tissue depths. This model was used to perform proton irradiations with different doses in both the plateau and the Bragg portions of the Bragg curve. The particular geometry of the wedge, in which the maximum thickness is greater than the proton range, yields a portion of unaffected tissue included in the irradiated area. Thus, it was possible to obtain a reference zone contiguous to the affected area in the same animal. SSNTD were used to establish the spatial configuration and the dose of the proton beams. This methodology allows isodose curve calculations along the different tissue depths which are in agreement with the biologic effects observed. Additionally, the scattering of protons on the shielding material, that affects specific areas of the tissue, is detected by the SSNTD. (author)

  4. Proton irradiation impacts age-driven modulations of cancer progression influenced by immune system transcriptome modifications from splenic tissue

    International Nuclear Information System (INIS)

    Wage, Justin; Ma, Lili; Peluso, Michael; Lamont, Clare; Hahnfeldt, Philip; Hlatky, Lynn; Beheshti, Afshin; Evens, Andrew M.

    2015-01-01

    Age plays a crucial role in the interplay between tumor and host, with additional impact due to irradiation. Proton irradiation of tumors induces biological modulations including inhibition of angiogenic and immune factors critical to 'hallmark' processes impacting tumor development. Proton irradiation has also provided promising results for proton therapy in cancer due to targeting advantages. Additionally, protons may contribute to the carcinogenesis risk from space travel (due to the high proportion of high-energy protons in space radiation). Through a systems biology approach, we investigated how host tissue (i.e. splenic tissue) of tumor-bearing mice was altered with age, with or without whole-body proton exposure. Transcriptome analysis was performed on splenic tissue from adolescent (68-day) versus old (736-day) C57BL/6 male mice injected with Lewis lung carcinoma cells with or without three fractionations of 0.5 Gy (1-GeV) proton irradiation. Global transcriptome analysis indicated that proton irradiation of adolescent hosts caused significant signaling changes within splenic tissues that support carcinogenesis within the mice, as compared with older subjects. Increases in cell cycling and immunosuppression in irradiated adolescent hosts with CDK2, MCM7, CD74 and RUVBL2 indicated these were the key genes involved in the regulatory changes in the host environment response (i.e. the spleen). Collectively, these results suggest that a significant biological component of proton irradiation is modulated by host age through promotion of carcinogenesis in adolescence and resistance to immunosuppression, carcinogenesis and genetic perturbation associated with advancing age. (author)

  5. Dose-volume effects in the rat cervical spinal cord after proton irradiation

    International Nuclear Information System (INIS)

    Bijl, Hendrik P.; Vuijk, Peter van; Coppes, Rob P.; Schippers, Jacobus M.; Konings, Antonius W.T.; Kogel, Albert J. van der

    2002-01-01

    Purpose: To estimate dose-volume effects in the rat cervical spinal cord with protons. Methods and Materials: Wistar rats were irradiated on the cervical spinal cord with a single fraction of unmodulated protons (150-190 MeV) using the shoot through method, which employs the plateau of the depth-dose profile rather than the Bragg peak. Four different lengths of the spinal cord (2, 4, 8, and 20 mm) were irradiated with variable doses. The endpoint for estimating dose-volume effects was paralysis of fore or hind limbs. Results: The results obtained with a high-precision proton beam showed a marginal increase of ED 50 when decreasing the irradiated cord length from 20 mm (ED 50 = 20.4 Gy) to 8 mm (ED 50 = 24.9 Gy), but a steep increase in ED 50 when further decreasing the length to 4 mm (ED 50 = 53.7 Gy) and 2 mm (ED 50 = 87.8 Gy). These results generally confirm data obtained previously in a limited series with 4-6-MV photons, and for the first time it was possible to construct complete dose-response curves down to lengths of 2 mm. At higher ED 50 values and shorter lengths irradiated, the latent period to paralysis decreased from 125 to 60 days. Conclusions: Irradiation of variable lengths of rat cervical spinal cord with protons showed steeply increasing ED 50 values for lengths of less than 8 mm. These results suggest the presence of a critical migration distance of 2-3 mm for cells involved in regeneration processes

  6. Comparison of gamma, neutron and proton irradiations of multimode fibers

    International Nuclear Information System (INIS)

    Gingerich, M.E.; Dorsey, K.L.; Askins, C.G.; Friebele, E.J.

    1987-01-01

    The effects of pure gamma, pure proton, and mixed neutron-gamma irradiation fields on a set of both pure and doped silica core multimode fibers have been investigated. Only slight differences are found in the radiation response of pure and doped silica core fibers exposed to gamma or mixed neutron-gamma fields, indicating that Co-60 sources can be used to simulate the effects of the mixed field (except in the case of a pure neutron environment). Although it is noted that neither mix field nor gamma sources adequately simulate the effects of proton irradiation of doped silica core fibers, a good correspondence is found in the case of the pure silica core waveguide. 13 references

  7. Low temperature irradiation of iron, zirconium and copper by 10 to 16 MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Omar, A M

    1978-01-01

    A theoretical analysis of scattering and radiation damage parameters is carried out for 14 MeV neutrons and 10-17 MeV protons on Fe, Ni, Cu, Zr, Nb, and Au. Damage energies are computed for the interactions using both elastic and non-elastic data. The results show that proton encounters deposit a greater damage energy than 14 MeV neutrons. To examine the theoretical results, electrical resistivity measurements are undertaken for Fe, Zr and Cu irradiated at 12 to 17.5K with 10 to 16 MeV protons. Post-irradiation annealing is carried out in situ using a closed-cycle helium-cooled cryostat. Values of the resistivity damage rate are compared with values estimated from the theoretical damage-energy results. Also, the observed stage I recovery is analysed in terms of the corresponding recovery reported for electron and fast-neutron irradiations. The relation between the 16 MeV proton data and published data estimated from a fusion reactor spectrum is discussed. It is also shown that protons create a damage structure similar to a superposition of the damage structures generated by electrons and fast neutrons. The sample state of imperfection is shown to influence the induced damage state in proton irradiation.

  8. Microstructure of laser floating zone (LFZ) textured (Bi,Pb)-Sr-Ca-Cu-O superconductor composites

    International Nuclear Information System (INIS)

    Fuente, G.F. de la; Ruiz, M.T.; Sotelo, A.; Larrea, A.; Navarro, R.

    1993-01-01

    Directionally solidified high temperature superconducting (Bi,Pb)-Sr-Ca-Cu-O pure ceramics and composites were obtained using a laser floating zone (LFZ) apparatus. The presence of secondary non-superconducting and metallic phases as well as their solidification habit have been analysed. The influence of the LFZ growth conditions and the precursor composition on the microstructure of the final products was studied using optical and electron microscopies. (orig.)

  9. Studies of physiology and the morphology of the cat LGN following proton irradiation

    International Nuclear Information System (INIS)

    Reder, Chad S.; Moyers, Michael F.; Lau, Daryl; Kirby, Michael A.

    2000-01-01

    Purpose: We have examined the effects of proton irradiation on the histologic and receptive field properties of thalamic relay cells in the cat visual system. The cat lateral geniculate nucleus (LGN) is a large structure with well-defined anatomical boundaries, and well-described afferent, efferent, and receptive field properties. Methods and Materials: A 1.0-mm proton microbeam was used on the cat LGN to determine short-term (3 months) and long-term (9 months) receptive field effects of irradiation on LGN relay cells. The doses used were 16-, 40-, and 60-gray (Gy). Results: Following irradiation, abnormalities in receptive field organization were found in 40- and 60-Gy short-term animals, and in all of the long-term animals. The abnormalities included 'silent' areas of the LGN where a visual response could not be evoked and other regions that had unusually large or small compound receptive fields. Histologic analysis failed to identify cellular necrosis or vascular damage in the irradiated LGN, but revealed a disruption in retinal afferents to areas of the LGN. Conclusions: These results indicate that microbeam proton irradiation can disrupt cellular function in the absence of obvious cellular necrosis. Moreover, the area and extent of this disruption increased with time, having larger affect with longer post-irradiation periods

  10. Radiation Damage in Silicon Detectors Caused by Hadronic and Electromagnetic Irradiation

    CERN Document Server

    Fretwurst, E.; Stahl, J.; Pintilie, I.

    2002-01-01

    The report contains various aspects of radiation damage in silicon detectors subjected to high intensity hadron and electromagnetic irradiation. It focuses on improvements for the foreseen LHC applications, employing oxygenation of silicon wafers during detector processing (result from CERN-RD48). An updated survey on hadron induced damage is given in the first article. Several improvements are outlined especially with respect to antiannealing problems associated with detector storage during LHC maintenance periods. Open questions are outlined in the final section, among which are a full understanding of differences found between proton and neutron induced damage, process related effects changing the radiation tolerance in addition to the oxygen content and the lack of understanding the changed detector properties on the basis of damage induced point and cluster defects. In addition to float zone silicon, so far entirely used for detector fabrication,Czochralski silicon was also studied and first promising re...

  11. Experimental study on gamma irradiation effects of floating gate ROMs The ROM is stated for Read-only Memory

    CERN Document Server

    He Chao Hui; Chen Xiao Hua; Wang Yan Ping; Peng Hong Lun

    2002-01-01

    Experimental results of gamma irradiation effects are given for Floating gate ROMs. There is an accumulated dose threshold. Errors occur when accumulated dose is above the threshold, no error occurs when below the threshold. The errors go up with the increase of the accumulated dose. Errors occur in devices that are measured during irradiation and irradiated in power on, moreover, new data cannot be written in these devices with programmer. However, under more accumulated dose, there is no error in devices in power off mode and new data can be written in these devices with programmer

  12. Development of over-production strain of saccharification enzyme and biomass pretreatment by proton beam irradiation

    International Nuclear Information System (INIS)

    Kim, S. O.; Lee, J. Y.; Song, Y. S.; Shin, H. S.

    2009-04-01

    - The first year : Pre-treatment of biomass by proton beam irradiation and characterization of the pretreated biomass by IR and SEM - The second year : Strain development by proton beam irradiation for the production of cellulase and hemicellulase - The third year : Optimization of Saccharification process by cellulase and hemicellulase

  13. IRRAD: The New 24GeV/c Proton Irradiation Facility at CERN

    CERN Document Server

    Gkotse, Blerina; Moll, Michael; Ravotti, Federico

    2016-01-01

    The proton and mixed-field irradiation facilities at the CERN PS East Area (known as IRRAD1 and IRRAD2), have been heavily exploited for irradiation of particle detectors, electronic components and materials since 1992. With the increasing demand of irradiation experiments, and in view of the High-Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC), these facilities suffered of a number of unpleasant restrictions such as the space availability, the maximum achievable particle flux and several access constraints. In the framework of the AIDA project, an upgrade of these facilities was carried out during the Long Shutdown 1 (LS1) of the CERN accelerator complex. The new combined East Area IRRADiation facility (EA-IRRAD) started the commissioning in October 2014. While the new proton facility (IRRAD) continue to be mainly devoted to the radiation hardness studies for the High Energy Physics community, the new mixed-field facility (CHARM) mainly hosts irradiation experiments for the validation of electr...

  14. Wavelength dependence in laser floating zone processing. A case study with Bi-Sr-Ca-Cu-O superconductors

    International Nuclear Information System (INIS)

    Fuente, G.F. de la; Diez, J.C.; Angurel, L.A.; Pena, J.I.; Sotelo, A.; Navarro, R.

    1995-01-01

    Laser floating zone processing methods are particularly suitable for studying crystal growth and the development of texture from the melt in many materials used in electrooptics, for example. A system is described that allows different laser wavelengths to be used, and first results on BSCCO superconducting fibers processed using different lasers are presented. (orig.)

  15. Internal friction measurements of Mo after low-temperature proton irradiation

    International Nuclear Information System (INIS)

    Tanimoto, H.; Mizubayashi, H.; Masuda, R.; Okuda, S.; Tagishi, Y.

    1992-01-01

    Internal friction measurements are performed in Mo after 20 MeV proton irradiation in order to clarify the behavior of self-interstitial atoms (SIA's) in Mo. In the low dose range, strong dislocation pinning suggesting the free migration of defects is observed at about 40 K and weak pinning at about 25 K. The features are very similar to those reported after neutron irradiation except that the 25 K pinning is much smaller after proton irradiation. The result suggests that the migration of free SIA's is responsible for the 40 K pinning and that of SIA-defect clusters, probably di-SIA's, formed during irradiation for the 25 K pinning. In the high dose range, the relaxation peaks are observed at about 13 and 41 K, where the close similarities are found between the present peaks and the corresponding peaks reported after neutron irradiation except that the peak height of the 41 K peak per unit concentration of Frenkel pairs (FP) tends to increase strongly with decreasing dose here. The latter fact suggests the strong interaction between SIA's. Then the smallness of the 41 K peak reported after electron irradiation with very high dose could be explained by an increased interaction between SIA's, but not by the two-dimensional migration of SIA's as proposed by Jacques and Robrock. Deformation given prior to irradiation causes a drastic decrease in the modulus defects associated with FP's (so-called bulk effect) and in the 13 K peak height. After neutron irradiation, no such effect of deformation was reported. A possible origin for this difference is discussed. (orig.)

  16. Comparison of the microstructure, deformation and crack initiation behavior of austenitic stainless steel irradiated in-reactor or with protons

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, Kale J., E-mail: kalejs@umich.edu; Was, Gary S.

    2015-01-15

    Highlights: • Dislocation loops were the prominent defect, but neutron irradiation caused higher loop density. • Grain boundaries had similar amounts of radiation-induced segregation. • The increment in hardness and yield stress due to irradiation were very similar. • Relative IASCC susceptibility was nearly identical. • The effect of dislocation channel step height on IASCC was similar. - Abstract: The objective of this study was to compare the microstructures, microchemistry, hardening, susceptibility to IASCC initiation, and deformation behavior resulting from proton or reactor irradiation. Two commercial purity and six high purity austenitic stainless steels with various solute element additions were compared. Samples of each alloy were irradiated in the BOR-60 fast reactor at 320 °C to doses between approximately 4 and 12 dpa or by a 3.2 MeV proton beam at 360 °C to a dose of 5.5 dpa. Irradiated microstructures consisted mainly of dislocation loops, which were similar in size but lower in density after proton irradiation. Both irradiation types resulted in the formation of Ni–Si rich precipitates in a high purity alloy with added Si, but several other high purity neutron irradiated alloys showed precipitation that was not observed after proton irradiation, likely due to their higher irradiation dose. Low densities of small voids were observed in several high purity proton irradiated alloys, and even lower densities in neutron irradiated alloys, implying void nucleation was in process. Elemental segregation at grain boundaries was very similar after each irradiation type. Constant extension rate tensile experiments on the alloys in simulated light water reactor environments showed excellent agreement in terms of the relative amounts of intergranular cracking, and an analysis of localized deformation after straining showed a similar response of cracking to surface step height after both irradiation types. Overall, excellent agreement was observed

  17. Development of abiotic-stress resistant warm season trufgrasses by proton-beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Y. W.; Kim, J. Y.; Jeong, S. H. [Korea Univ., Seoul (Korea, Republic of)

    2007-04-15

    The direct use of mutation is a valuable approach to generate genetic variation in crop species by altering agronomically useful major traits. The proton beam, as a mutagen, was applied to improve resistance traits of Zoysia grass under various abiotic stresses. Proton beam was irradiated to mature dry seeds of Zenith (Zoysia grass), which is well-adapted to Korean climate, using a proton- accelerator with seven different doses (50, 100, 150, 200, 250, 300, 400 Gy). Individual seedling of M1 plant was transplanted from the seed bed and allowed to reach appropriate plant mass. Clones that showed superior growth were chosen and transplanted to pots for further clone propagation and field evaluation. Growth characteristics of turfgrass, such as plant height, leaf length, leaf width, number of tiller were evaluated ninety days after sowing. Although large variation within each dose, noticeable differences were found among different irradiated doses. Most of the mutant clones derived from the irradiation treatment showed more vigorous growth than the control plants. RAPD (Random Amplified Polymorphic DNA) and AFLP (Amplified Fragment Length Polymorphism) methods were conducted to analyze genomic variations associated with proton beam irradiation. In order to establish selection criteria for selection of salt-stress resistance plants, an in vitro method that is able to select salt-stress resistant mutants in liquid media without ambient disturbances. Total 647 predominance clones that were considered as abiotic stress resistant mutants were transplanted to the field for further evaluation.

  18. Measurement of proton autoneutralization potential

    International Nuclear Information System (INIS)

    Garcia, M.

    1984-09-01

    A proton space charge having multi-MeV kinetic energy was injected through a thin ground plane to extract electrons and produce a time-dependent autoneutralization space potential. An electon-emitting floating-potential resistive divider was used to measure the space potential during 20 ns of the proton current pulse. During this time, proton kinetic energy fell from 10.6 MeV to 8.5 MeV and thus the space potential (taken as 1.09 x the floating potential) fell from 5.8 kV to 4.6 kV

  19. Performance of a proton irradiation chamber

    International Nuclear Information System (INIS)

    Agosteo, S.; Borsato, E.; Dal Corso, F.; Fazzi, A.; Gonella, F.; Introini, M.V.; Lippi, I.; Lorenzoli, M.; Modenese, L.; Montecassiano, F.; Pegoraro, M.; Pola, A.; Varoli, V.; Zotto, P.

    2012-01-01

    A Proton Irradiation Chamber aiming to perform radiation tests of electronic components was developed. The precision on the measurement of the ion currents was pushed beyond the resolution of the picoammeter by means of a series of collimators on the beam showing a linear correlation among the currents measured on them and the smaller, not measurable, current on the target. As an example of the obtained results the tests done on a Si microdosimeter and a power p-MOS are reported.

  20. Performance of a proton irradiation chamber

    Energy Technology Data Exchange (ETDEWEB)

    Agosteo, S. [INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare-CeSNEF, via Ponzio 34/3 20133 Milano (Italy); Borsato, E. [INFN, Sezione di Padova, via Marzolo 8, 35131 Padova (Italy); Universita di Padova, Dipartimento di Fisica, via Marzolo 8, 35131 Padova (Italy); Dal Corso, F. [INFN, Sezione di Padova, via Marzolo 8, 35131 Padova (Italy); Fazzi, A. [INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare-CeSNEF, via Ponzio 34/3 20133 Milano (Italy); Gonella, F. [INFN, Sezione di Padova, via Marzolo 8, 35131 Padova (Italy); Introini, M.V. [INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare-CeSNEF, via Ponzio 34/3 20133 Milano (Italy); Lippi, I. [INFN, Sezione di Padova, via Marzolo 8, 35131 Padova (Italy); Lorenzoli, M. [INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare-CeSNEF, via Ponzio 34/3 20133 Milano (Italy); Modenese, L.; Montecassiano, F.; Pegoraro, M. [INFN, Sezione di Padova, via Marzolo 8, 35131 Padova (Italy); Pola, A.; Varoli, V. [INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Politecnico di Milano, Dipartimento di Energia, Sezione di Ingegneria Nucleare-CeSNEF, via Ponzio 34/3 20133 Milano (Italy); Zotto, P., E-mail: pierluigi.zotto@pd.infn.it [INFN, Sezione di Padova, via Marzolo 8, 35131 Padova (Italy); Universita di Padova, Dipartimento di Fisica, via Marzolo 8, 35131 Padova (Italy)

    2012-02-01

    A Proton Irradiation Chamber aiming to perform radiation tests of electronic components was developed. The precision on the measurement of the ion currents was pushed beyond the resolution of the picoammeter by means of a series of collimators on the beam showing a linear correlation among the currents measured on them and the smaller, not measurable, current on the target. As an example of the obtained results the tests done on a Si microdosimeter and a power p-MOS are reported.

  1. Plastic zone size for nanoindentation of irradiated Fe–9%Cr ODS

    Energy Technology Data Exchange (ETDEWEB)

    Dolph, Corey K. [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Silva, Douglas J. da [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Federal University of São Carlos, Rodovia Washington Luís, km 235 - SP-310, São Carlos, São Paulo (Brazil); Swenson, Matthew J. [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Wharry, Janelle P., E-mail: jwharry@purdue.edu [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Purdue University, 400 Central Drive, West Lafayette, IN 47907 (United States)

    2016-12-01

    The objective of this study is to determine irradiation effects on the nanoindentation plastic zone morphology in a model Fe–9%Cr ODS alloy. Specimens are irradiated to 50 displacements per atom at 400°C with Fe{sup ++} self-ions or to 3 dpa at 500°C with neutrons. The as-received specimen is also studied as a control. The nanoindentation plastic zone size is calculated using two approaches: (1) an analytical model based on the expanding spherical cavity analogy, and (2) finite element modeling (FEM). Plastic zones in all specimen conditions extend radially outward from the indenter, ∼4–5 times the tip radius, indicative of fully plastic contact. Non-negligible plastic flow in the radial direction requires the experimentalist to consider the plastic zone morphology when nanoindenting ion-irradiated specimens; a single nanoindent may sample non-uniform irradiation damage, regardless of whether the indent is made top-down or in cross-section. Finally, true stress-strain curves are generated.

  2. High-energy and high-fluence proton irradiation effects in silicon solar cells

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Taylor, S.J.; Yang, M.; Matsuda, S.; Kawasaki, O.; Hisamatsu, T.

    1996-01-01

    We have examined proton irradiation damage in high-energy (1 endash 10 MeV) and high-fluence (approx-gt 10 13 cm -2 ) Si n + -p-p + structure space solar cells. Radiation testing has revealed an anomalous increase in short-circuit current I sc followed by an abrupt decrease and cell failure, induced by high-fluence proton irradiation. We propose a model to explain these phenomena by expressing the change in carrier concentration p of the base region as a function of the proton fluence in addition to the well-known model where the short-circuit current is decreased by minority-carrier lifetime reduction after irradiation. The reduction in carrier concentration due to majority-carrier trapping by radiation-induced defects has two effects. First, broadening of the depletion layer increases both the generation endash recombination current and also the contribution of the photocurrent generated in this region to the total photocurrent. Second, the resistivity of the base layer is increased, resulting in the abrupt decrease in the short circuit current and failure of the solar cells. copyright 1996 American Institute of Physics

  3. Response of thyroid follicular cells to gamma irradiation compared to proton irradiation. I. Initial characterization of DNA damage, micronucleus formation, apoptosis, cell survival, and cell cycle phase redistribution

    Science.gov (United States)

    Green, L. M.; Murray, D. K.; Bant, A. M.; Kazarians, G.; Moyers, M. F.; Nelson, G. A.; Tran, D. T.

    2001-01-01

    The RBE of protons has been assumed to be equivalent to that of photons. The objective of this study was to determine whether radiation-induced DNA and chromosome damage, apoptosis, cell killing and cell cycling in organized epithelial cells was influenced by radiation quality. Thyroid-stimulating hormone-dependent Fischer rat thyroid cells, established as follicles, were exposed to gamma rays or proton beams delivered acutely over a range of physical doses. Gamma-irradiated cells were able to repair DNA damage relatively rapidly so that by 1 h postirradiation they had approximately 20% fewer exposed 3' ends than their counterparts that had been irradiated with proton beams. The persistence of free ends of DNA in the samples irradiated with the proton beam implies that either more initial breaks or a quantitatively different type of damage had occurred. These results were further supported by an increased frequency of chromosomal damage as measured by the presence of micronuclei. Proton-beam irradiation induced micronuclei at a rate of 2.4% per gray, which at 12 Gy translated to 40% more micronuclei than in comparable gamma-irradiated cultures. The higher rate of micronucleus formation and the presence of larger micronuclei in proton-irradiated cells was further evidence that a qualitatively more severe class of damage had been induced than was induced by gamma rays. Differences in the type of damage produced were detected in the apoptosis assay, wherein a significant lag in the induction of apoptosis occurred after gamma irradiation that did not occur with protons. The more immediate expression of apoptotic cells in the cultures irradiated with the proton beam suggests that the damage inflicted was more severe. Alternatively, the cell cycle checkpoint mechanisms required for recovery from such damage might not have been invoked. Differences based on radiation quality were also evident in the alpha components of cell survival curves (0.05 Gy(-1) for gamma rays, 0

  4. Radiation hardness of silicon detectors manufactured on epitaxial material and FZ bulk enriched with oxygen, carbon, tin and platinum

    CERN Document Server

    Ruzin, A; Glaser, M; Lemeilleur, F; Talamonti, R; Watts, S; Zanet, A

    1999-01-01

    Recent results on the radiation hardness of silicon detectors fabricated on epitaxial and float zone bulk silicon enriched by various impurities, such as carbon, oxygen, tin and platinum are reported. A new methodology of measurements of electrical properties of the devices has been utilized in the experiment. It has been shown that in the case of irradiation by protons, oxygen enriched silicon has better radiation hardness than standard float zone silicon. The carbon enriched silicon detectors, on the other hand, exhibited significantly inferior radiation hardness compared to standard detectors. This study shows for the first time, a violation of the widely used normalization technique of the various particle irradiations by NIEL coefficients. The study has been carried out in the framework of the RD48 (ROSE) collaboration, which studies the radiation hardening of silicon detectors. (5 refs).

  5. Global peak flux profile of proton precipitation in the equatorial zone

    International Nuclear Information System (INIS)

    Miah, M.A.

    1991-01-01

    Particle precipitation near the equator within ± 30deg geomagnetic latitude was investigated by the Phoenix-1 instrumentation on board the S81-1 mission. The monitor telescope on board the mission was sensitive to protons in the energy range 0.6-9.1 MeV, to alpha particles in the energy range 0.4-80 MeV/nucleon and Z→3 particles ( 12 C) of energy greater than 0.7 MeV/nucleon. The peak efficiency of the telescope was for particles of ∼88deg pitch angles at the line of minimum magnetic field. Careful separation of the magnetically quiet time equatorial particle data from global data coverage and subsequent analysis shows that the ML detector on board the mission detected mostly protons. The proton peak flux profile follows the line of minimum magnetic field. The full width at half maximum (FWHM) of the equatorial zone is ∼ 13deg, which is well within the EUV emission zone. (author). 14 refs., 9 figs

  6. Observations of defect structure evolution in proton and Ni ion irradiated Ni-Cr binary alloys

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Samuel A., E-mail: sabriggs2@wisc.edu [University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI 53706 (United States); Barr, Christopher M. [Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Pakarinen, Janne [University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI 53706 (United States); SKC-CEN Belgian Nuclear Research Centre, Boeretang 200, B-2400 Mol (Belgium); Mamivand, Mahmood [University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI 53706 (United States); Hattar, Khalid [Sandia National Laboratories, PO Box 5800, Albuquerque, NM 87185 (United States); Morgan, Dane D. [University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI 53706 (United States); Taheri, Mitra [Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Sridharan, Kumar [University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI 53706 (United States)

    2016-10-15

    Two binary Ni-Cr model alloys with 5 wt% Cr and 18 wt% Cr were irradiated using 2 MeV protons at 400 and 500 °C and 20 MeV Ni{sup 4+} ions at 500 °C to investigate microstructural evolution as a function of composition, irradiation temperature, and irradiating ion species. Transmission electron microscopy (TEM) was applied to study irradiation-induced void and faulted Frank loops microstructures. Irradiations at 500 °C were shown to generate decreased densities of larger defects, likely due to increased barriers to defect nucleation as compared to 400 °C irradiations. Heavy ion irradiation resulted in a larger density of smaller voids when compared to proton irradiations, indicating in-cascade clustering of point defects. Cluster dynamics simulations were in good agreement with the experimental findings, suggesting that increases in Cr content lead to an increase in interstitial binding energy, leading to higher densities of smaller dislocation loops in the Ni-18Cr alloy as compared to the Ni-5Cr alloy. - Highlights: • Binary Ni-Cr alloys were irradiated with protons or Ni ions at 400 and 500 °C. • Higher irradiation temperatures yield increased size, decreased density of defects. • Hypothesize that varying Cr content affects interstitial binding energy. • Fitting CD models for loop nucleation to data supports this hypothesis.

  7. Comparison of proton microbeam and gamma irradiation for the radiation hardness testing of silicon PIN diodes

    Science.gov (United States)

    Jakšić, M.; Grilj, V.; Skukan, N.; Majer, M.; Jung, H. K.; Kim, J. Y.; Lee, N. H.

    2013-09-01

    Simple and cost-effective solutions using Si PIN diodes as detectors are presently utilized in various radiation-related applications in which excessive exposure to radiation degrades their charge transport properties. One of the conventional methods for the radiation hardness testing of such devices is time-consuming irradiation with electron beam or gamma-ray irradiation facilities, high-energy proton accelerators, or with neutrons from research reactors. Recently, for the purpose of radiation hardness testing, a much faster nuclear microprobe based approach utilizing proton irradiation has been developed. To compare the two different irradiation techniques, silicon PIN diodes have been irradiated with a Co-60 gamma radiation source and with a 6 MeV proton microbeam. The signal degradation in the silicon PIN diodes for both irradiation conditions has been probed by the IBIC (ion beam induced charge) technique, which can precisely monitor changes in charge collection efficiency. The results presented are reviewed on the basis of displacement damage calculations and NIEL (non-ionizing energy loss) concept.

  8. Proteomic analysis of proton beam irradiated human melanoma cells.

    Directory of Open Access Journals (Sweden)

    Sylwia Kedracka-Krok

    Full Text Available Proton beam irradiation is a form of advanced radiotherapy providing superior distributions of a low LET radiation dose relative to that of photon therapy for the treatment of cancer. Even though this clinical treatment has been developing for several decades, the proton radiobiology critical to the optimization of proton radiotherapy is far from being understood. Proteomic changes were analyzed in human melanoma cells treated with a sublethal dose (3 Gy of proton beam irradiation. The results were compared with untreated cells. Two-dimensional electrophoresis was performed with mass spectrometry to identify the proteins. At the dose of 3 Gy a minimal slowdown in proliferation rate was seen, as well as some DNA damage. After allowing time for damage repair, the proteomic analysis was performed. In total 17 protein levels were found to significantly (more than 1.5 times change: 4 downregulated and 13 upregulated. Functionally, they represent four categories: (i DNA repair and RNA regulation (VCP, MVP, STRAP, FAB-2, Lamine A/C, GAPDH, (ii cell survival and stress response (STRAP, MCM7, Annexin 7, MVP, Caprin-1, PDCD6, VCP, HSP70, (iii cell metabolism (TIM, GAPDH, VCP, and (iv cytoskeleton and motility (Moesin, Actinin 4, FAB-2, Vimentin, Annexin 7, Lamine A/C, Lamine B. A substantial decrease (2.3 x was seen in the level of vimentin, a marker of epithelial to mesenchymal transition and the metastatic properties of melanoma.

  9. Proton and photon absorbed-dose conversion coefficients for embryo and foetus from top-down irradiation geometry

    International Nuclear Information System (INIS)

    Chen, J.

    2007-01-01

    Absorbed-dose conversion coefficients are calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months when the mother's body is exposed to protons and photons from top-down (TOP) direction. It provides data sets in addition to other standard irradiation geometries published previously. The TOP-irradiation geometry is considered here, because high-energy particles are often peaked from the TOP direction onboard aircraft. The results show that absorbed-doses from high-energy particles could be underestimated significantly if isotropic (ISO) irradiation geometry is assumed. For protons of 100 GeV, absorbed-doses from TOP irradiation are ∼2.3-2.9 times higher than the doses from ISO irradiation for different foetal ages. For 10 GeV photons, foetal doses from TOP irradiation are ∼6.8-12 times higher than the doses from ISO irradiation. The coefficients from TOP-irradiation geometry are given in wide energy ranges, from 100 MeV to 100 GeV for protons and from 50 V to 10 GeV for photons. They can, therefore, be used in various applications whenever exposure from the TOP-irradiation direction is concerned. (authors)

  10. Dependence of the annealing kinetics of A centers and divacancies on temperature, particle energy, and irradiation dose for n-Si crystals

    International Nuclear Information System (INIS)

    Pagava, T.A.

    2002-01-01

    n-Si crystals grown by the float-zone method with a phosphorus concentration of ∼6 x 10 13 cm -3 and irradiated with 2-MeV electrons and 25-MeV protons were studied. It is shown that the kinetics of the isochronous annealing of the A centers and divacancies (the annealing temperature and the rearrangement of radiation defects in the situation where the dissociation of one type of defects gives rise to more stable defects) depends in a complicated way on the energy, dose, and temperature of irradiation; i.e., this kinetics depends on the relation between the concentrations of various radiation defects and on the charge state of reacting primary radiation defects when they interact with each other, with impurity atoms, and with disordered regions. An increase in the concentration of divacancies in the temperature range of 180-210 deg. C is attributed to the dissociation of disordered regions

  11. Evolving role of hadron irradiation: Potential and risks of hadrons heavier than protons

    International Nuclear Information System (INIS)

    Levy, Richard P.

    2007-01-01

    Proton irradiation has been developed to achieve the clinical benefit of improved 3D-dose distribution, with biological properties similar to X-rays. Neutron irradiation, though much less 3D-conformal than proton treatment, has been developed to take advantage of increased relative biologic effectiveness (RBE). Irradiation with hadrons heavier than protons (e.g. carbon and neon ions) exhibits the unique combination of improved 3D-dose distribution and increased RBE. The synchrotron technology is rapidly developing to improve the efficiency of delivering these heavier hadrons clinically, but important issues remain regarding optimization of dose and fractionation parameters in the treatment of various histopathologies located in different portions of the anatomy. Many laboratory animal and in vitro cellular studies, and some clinical studies, have been performed to enable better understanding of how to adjust dose-fractionation selection to improve the therapeutic ratio of tumor-cell kill to normal-tissue injury. This paper highlights the enhanced therapeutic potential and associated risks of treatment with these heavier hadrons

  12. A simple irradiation facility for radiobiological experiments with low energy protons from a cyclotron

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1982-01-01

    An experimental facility for irradiation of small biological targets with low-energy protons has been developed. The depth-dose distribution in soft-tissue is calculated from the proton energy spectrum. (orig.)

  13. Proton microbeam irradiation effects on PtBA polymer

    Indian Academy of Sciences (India)

    Microbeam irradiation effects on poly-tert-butyl-acrylate (PtBA) polymer using 2.0 MeV proton microbeam are reported. Preliminary results on pattern formation on PtBA are carried out as a function of fluence. After writing the pattern, a thin layer of Ge is deposited. Distribution of Ge in pristine and ion beam patterned surface ...

  14. X-ray diffraction studies of 145MeV proton-irradiated AlBeMet 162

    Directory of Open Access Journals (Sweden)

    Mohamed Elbakhshwan

    2016-08-01

    Full Text Available AlBeMet 162 (Materion Co., formerly Brush Wellman has been irradiated with 145MeV protons up to 1.2×1020cm−2 fluence, with irradiation temperatures in the range of 100–220°C. Macroscopic post-irradiation evaluation on the evolution of mechanical and thermal properties was integrated with a comprehensive X-ray- diffraction study using high-energy monochromatic and polychromatic X-ray beams, which offered a microscopic view of the irradiation damage effects on AlBeMet. The study confirmed the stability of the metal–matrix composite, its resistance to proton damage, and the continuing separation of the two distinct phases, fcc aluminum and hcp beryllium, following irradiation. Furthermore, based on the absence of inter-planar distance change during proton irradiation, it was confirmed that the stacking faults and clusters on the Al (111 planes are stable, and thus can migrate from the cascade region and be absorbed at various sinks. XRD analysis of the unirradiated AlBeMet 162 showed clear change in the texture of the fcc phase with orientation especially in the Al (111 reflection which exhibits a “non-perfect” six-fold symmetry, implying lack of isotropy in the composite.

  15. Photosynthetic response of the floating-leaved macrophyte Nymphoides peltata to a temporary terrestrial habitat and its implications for ecological recovery of Lakeside zones

    Directory of Open Access Journals (Sweden)

    Yu H.

    2014-01-01

    Full Text Available For the ecological recovery of lakeside zones in shallow eutrophic lakes, choosing suitable aquatic macrophytes which could adapt to the temporary terrestrial habitat due to water level change is very important. In the present study, an experimental approach was carried out to explore the photosynthetic response of the typical floating-leaved aquatic plant Nymphoides peltata (N. peltata to varying environmental factors. N. peltata grown under aquatic and terrestrial habitats showed similar photosynthesis-irradiance response patterns. The investigation of diurnal changes in gas exchange revealed that the net photosynthetic rate (PN and water-use efficiency (WUE of the N. peltata grown in the terrestrial habitat were 68% and 94% higher, respectively, than those in the aquatic habitat at nine in the morning. N. peltata grown in the terrestrial habitat had approximately 51% less stomatal density and a 77% smaller stomatal aperture area compared with those grown in aquatic habitats. The above results indicated that N. peltata could be well-acclimated to the terrestrial habitat by developing a series of photosynthetic acclimation features. Our study may provide an important reference for restoration in lakeside zones of shallow eutrophic lakes.

  16. MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

    International Nuclear Information System (INIS)

    Yamamoto, S; Komori, M; Toshito, T; Watabe, H

    2016-01-01

    Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

  17. MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, S; Komori, M [Nagoya University, Nagoya, Aichi (Japan); Toshito, T [Nagoya Proton Therapy Center, Nagoya, Aichi (Japan); Watabe, H [Tohoku University, Sendai, Miyagi (Japan)

    2016-06-15

    Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

  18. Damage effects and mechanisms of proton irradiation on methyl silicone rubber

    International Nuclear Information System (INIS)

    Zhang, L.X.; He, Sh.Y.; Xu, Zh.; Wei, Q.

    2004-01-01

    A study was performed on the damage effects and mechanisms of proton irradiation with 150 keV energy to space-grade methyl silicone rubber. The changes in surface morphology, mechanical properties, infrared attenuated total reflection (ATR) spectrum, mass spectrum and pyrolysis gas chromatography-mass spectrum (PYGC-MS) indicated that, under lower fluence, the proton radiation would induce cross-linking effect, resulting in an increase in tensile strengths and hardness of the methyl silicon rubber. However, under higher proton fluence, the radiation-induced degradation, which decreased the tensile strengths and hardness, became a dominant effect. A macromolecular-network destruction model for the silicone rubber radiated with the protons was proposed

  19. Irradiation of a 2.5 m long SciFi module with 24 GeV/c protons to the dose profile expected in LHCb

    CERN Document Server

    Rodrigues Cavalcante, Ana Barbara; Glaser, Maurice; Joram, Christian; Karacson, Matthias; Kristic, Robert; Ravotti, Federico; Riggaz, Nicolas

    2015-01-01

    A 2.5 m long and 13 cm wide SciFi module, made of a 6-layer single fibre mat, was irradiated with 24 GeV/c protons in the new CERN PS IRRAD facility. The module is equipped with an aluminised mylar mirror and was previously carefully characterised in a test beam experiment in the CERN H8 zone. For the irradiation the module was tilted by $7 ^o$ w.r.t. the beam axis. A translation table allowed to move the module during the irradiation transverse to the beam in order to generate the dose distribution expected in LHCb after an integrated luminosity of 50 fb$^{-1}$, including the very sharp rise at the mirror end to 35 kGy. The dose distribution was derived from the generation of sodium isotopes in the aluminium strips placed in front of and behind the module. The dosimetry relies mainly on the activity of the long-lived Na-22 isotope, as the short-lived Na-24 gave in our specific case less precise results. The irradiated zone corresponds to an approximately 25 mm wide band running along the fibre mat, at 32 mm ...

  20. High-gain bipolar detector on float-zone silicon

    Science.gov (United States)

    Han, D. J.; Batignani, G.; Del Guerra, A.; Dalla Betta, G.-F.; Boscardin, M.; Bosisio, L.; Giorgi, M.; Forti, F.

    2003-10-01

    Since the float-zone (FZ) silicon has lower contaminations and longer minority-carrier lifetime than those in Czochralski silicon and other semiconductor materials, it has potential advantages to fabricate bipolar detectors on the high-purity FZ silicon substrate to achieve a high gain at ultra-low-signal levels. The authors present preliminary experimental results on a bipolar detector fabricated on an unusual high-purity FZ silicon substrate. A backside gettering layer of phosphorus-doped polysilicon was employed to preserve the long carrier lifetime of the high-purity FZ silicon. The device has been investigated in the detection of a continuous flux of X-ray and infrared light. The bipolar detector with a circular emitter of 2 mm diameter has demonstrated high gains up to 3820 for 22 keV X-ray from a 1 mCi Cd radioactive source (the X-ray photon flux, received by the detector is estimated to be ˜7.77×10 4/s). High gain up to 4400 for 0.17 nW light with a wavelength of 0.83 μm has been observed for the same device.

  1. High-gain bipolar detector on float-zone silicon

    International Nuclear Information System (INIS)

    Han, D.J.; Batignani, G.; Guerra, A.D.A. Del; Dalla Betta, G.-F.; Boscardin, M.; Bosisio, L.; Giorgi, M.; Forti, F.

    2003-01-01

    Since the float-zone (FZ) silicon has lower contaminations and longer minority-carrier lifetime than those in Czochralski silicon and other semiconductor materials, it has potential advantages to fabricate bipolar detectors on the high-purity FZ silicon substrate to achieve a high gain at ultra-low-signal levels. The authors present preliminary experimental results on a bipolar detector fabricated on an unusual high-purity FZ silicon substrate. A backside gettering layer of phosphorus-doped polysilicon was employed to preserve the long carrier lifetime of the high-purity FZ silicon. The device has been investigated in the detection of a continuous flux of X-ray and infrared light. The bipolar detector with a circular emitter of 2 mm diameter has demonstrated high gains up to 3820 for 22 keV X-ray from a 1 mCi Cd radioactive source (the X-ray photon flux, received by the detector is estimated to be ∼7.77x10 4 /s). High gain up to 4400 for 0.17 nW light with a wavelength of 0.83 μm has been observed for the same device

  2. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    Science.gov (United States)

    Meier, D.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Manfredi, P. F.; Marshall, R. D.; Mishina, M.; Le Normand, F.; Pan, L. S.; Palmieri, V. G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.; RD42 Collaboration

    1999-04-01

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/ c and 500 Mev protons up to a fluence of 5×10 15 p/cm 2. We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1×10 15 p/cm 2 and decreases by ≈40% at 5×10 15 p/cm 2. Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/ c and 500 MeV protons up to at least 1×10 15p/cm 2 without signal loss.

  3. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    International Nuclear Information System (INIS)

    Meier, D.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Manfredi, P.F.; Marshall, R.D.; Mishina, M.; Le Normand, F.; Pan, L.S.; Palmieri, V.G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R.J.; Tesarek, R.; Thomson, G.B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M.

    1999-01-01

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/c and 500 Mev protons up to a fluence of 5x10 15 p/cm 2 . We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1x10 15 p/cm 2 and decreases by ∼40% at 5x10 15 p/cm 2 . Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/c and 500 MeV protons up to at least 1x10 15 p/cm 2 without signal loss

  4. Supine craniospinal irradiation in pediatric patients by proton pencil beam scanning.

    Science.gov (United States)

    Farace, Paolo; Bizzocchi, Nicola; Righetto, Roberto; Fellin, Francesco; Fracchiolla, Francesco; Lorentini, Stefano; Widesott, Lamberto; Algranati, Carlo; Rombi, Barbara; Vennarini, Sabina; Amichetti, Maurizio; Schwarz, Marco

    2017-04-01

    Proton therapy is the emerging treatment modality for craniospinal irradiation (CSI) in pediatric patients. Herein, special methods adopted for CSI at proton Therapy Center of Trento by pencil beam scanning (PBS) are comprehensively described. Twelve pediatric patients were treated by proton PBS using two/three isocenters. Special methods refer to: (i) patient positioning in supine position on immobilization devices crossed by the beams; (ii) planning field-junctions via the ancillary-beam technique; (iii) achieving lens-sparing by three-beams whole-brain-irradiation; (iv) applying a movable-snout and beam-splitting technique to reduce the lateral penumbra. Patient-specific quality assurance (QA) program was performed using two-dimensional ion chamber array and γ-analysis. Daily kilovoltage alignment was performed. PBS allowed to obtain optimal target coverage (mean D98%>98%) with reduced dose to organs-at-risk. Lens sparing was obtained (mean D1∼730cGyE). Reducing lateral penumbra decreased the dose to the kidneys (mean Dmean4cm (mean γ>95%) than at depths<4cm. The reported methods allowed to effectively perform proton PBS CSI. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. High total dose proton irradiation effects on silicon NPN rf power transistors

    International Nuclear Information System (INIS)

    Bharathi, M. N.; Praveen, K. C.; Prakash, A. P. Gnana; Pushpa, N.

    2014-01-01

    The effects of 3 MeV proton irradiation on the I-V characteristics of NPN rf power transistors were studied in the dose range of 100 Krad to 100 Mrad. The different electrical characteristics like Gummel, current gain and output characteristics were systematically studied before and after irradiation. The recovery in the I-V characteristics of irradiated NPN BJTs were studied by isochronal and isothermal annealing methods

  6. High total dose proton irradiation effects on silicon NPN rf power transistors

    Energy Technology Data Exchange (ETDEWEB)

    Bharathi, M. N.; Praveen, K. C.; Prakash, A. P. Gnana, E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore-570006, Karnataka (India); Pushpa, N. [Department of PG Studies in Physics, JSS College, Ooty Road, Mysore-570025, Karnataka (India)

    2014-04-24

    The effects of 3 MeV proton irradiation on the I-V characteristics of NPN rf power transistors were studied in the dose range of 100 Krad to 100 Mrad. The different electrical characteristics like Gummel, current gain and output characteristics were systematically studied before and after irradiation. The recovery in the I-V characteristics of irradiated NPN BJTs were studied by isochronal and isothermal annealing methods.

  7. Irradiation effects of 11 MeV protons on ferritic steels

    International Nuclear Information System (INIS)

    Hamaguchi, Yoshikazu; Kuwano, Hisashi; Misawa, Toshihei

    1985-01-01

    It is considered that ferritic/martensitic steels are the candidate of the first wall materials for future fusion reactors. The most serious problem in the candidate materials is the loss of ductility due to the elevation of ductile-brittle transition temperature by the high dpa irradiation of neutrons. 14 MeV neutrons produced by D-T reaction cause high dpa damage and also produce large quantity of helium and hydrogen atoms in first wall materials. Those gas atoms also play an important role in the embrittlement of steels. The main purpose of this work was to simulate the behavior of hydrogen produced by the transmutation in the mechanical properties of ferritic steels when they were irradiated with 11 MeV protons. The experimental procedure and the results of hardness, the broadening of x-ray diffraction lines, Moessbauer spectroscopy and small punch test are reported. High energy protons of 10 - 20 MeV are suitable to the simulation experiment of 14 MeV neutron radiation damage. But the production of the active nuclei emitting high energy gamma ray and having long life, Co-56, is the most serious problem. Another difficulty is the control of irradiation temperature. A small irradiation chamber must be developed. (Kako, I.)

  8. Proton irradiation studies on Al and Al5083 alloy

    Science.gov (United States)

    Bhattacharyya, P.; Gayathri, N.; Bhattacharya, M.; Gupta, A. Dutta; Sarkar, Apu; Dhar, S.; Mitra, M. K.; Mukherjee, P.

    2017-10-01

    The change in the microstructural parameters and microhardness values in 6.5 MeV proton irradiated pure Al and Al5083 alloy samples have been evaluated using different model based techniques of X-ray diffraction Line Profile Analysis (XRD) and microindendation techniques. The detailed line profile analysis of the XRD data showed that the domain size increases and saturates with irradiation dose both in the case of Al and Al5083 alloy. The corresponding microstrain values did not show any change with irradiation dose in the case of the pure Al but showed an increase at higher irradiation doses in the case of Al5083 alloy. The microindendation results showed that unirradiated Al5083 alloy has higher hardness value compared to that of unirradiated pure Al. The hardness increased marginally with irradiation dose in the case of Al5083, whereas for pure Al, there was no significant change with dose.

  9. Modifications in track registration response of PADC detector by energetic protons

    CERN Document Server

    Dwivedi, K K; Fink, D; Mishra, R; Tripathy, S P; Kulshreshtha, A; Khathing, D T

    1999-01-01

    It has been well established that different ionising radiations modify the track registration properties of dielectric solids. In an effort to study the response of Polyallyl diglycol carbonate (PADC Homalite) detector towards fission fragment, PADC detectors were exposed to 10 sup 4 Gy dose of 62 MeV protons and then one set of samples were exposed to fission fragments from a sup 2 sup 5 sup 2 Cf source. Two of these detectors were containing a thin layer of Buckminsterfullerene (C sub 6 sub 0). The study of the etched tracks by Leitz Optical Microscope reveals that the track diameters are enhanced by more than 70% in the proton irradiated zone as compared to that in the unirradiated zone. Scanning Electron Microscopy was performed after etching the sample in 6 N NaOH at 55 deg. C for different etching times, to study the details of the surface modifications due to proton irradiation of PADC detectors with and without C sub 6 sub 0 layer. Our observations revealed that the diameters and density of proton tra...

  10. Selective Adsorption of Nano-bio materials and nanostructure fabrication on Molecular Resists Modified by proton beam irradiation

    International Nuclear Information System (INIS)

    Lee, H. W.; Kim, H. S.; Kim, S. M.

    2008-04-01

    The purpose of this research is the fabrication of nanostructures on silicon substrate using proton beam and selectively adsorption of bio-nano materials on the patterned substrate. Recently, the miniaturization of the integrated devices with fine functional structures was intensively investigated, based on combination of nanotechnology (NT), biotechnology (BT) and information technology (IT). Because of the inherent limitation in optical lithography, large variety of novel patterning technologies were evolved to construct nano-structures onto a substrate. Atomic force microscope-based nanolithography has readily formed sub-50 nm patterns by the local modification of a substrate using a probe with a curvature of 10 nm. The surface property was regarded as one of the most important factors for AFM-based nanolithography as well as for other novel nanolithographies. The molecular thin films such as a self-assembled monolayer or a polymer resist layer have been used as an alternative to modifying the surface property. Although proton or ion beam irradiation has been used as an efficient tool to modify the physical, chemical and electrical properties of a surface, the nano-patterning on the substrate or the molecular film modified with the beam irradiation has hardly been studied at both home and abroad. The selective adsorption of nano-bio materials such as carbon nanotubes and proteins on the patterns would contribute to developing the integrated devices. The polystyrene nanoparticles (400 nm) were arrayed on al silicon surface using nanosphere lithography and the various nanopatterns were fabricated by proton beam irradiation on the polystyrene nanoparticles arrayed silicon surface. We obtained the two different nanopatterns such as polymer nanoring patterns and silicon oxide patterns on the same silicon substrate. The polymer nanoring patterns formed by the crosslinkage of polystyrene when proton beam was irradiated at the triangular void spaces that are enclosed by

  11. Effects of proton beam irradiation on seed germination and growth of soybean ( Glycine max L. Merr.)

    Science.gov (United States)

    Im, Juhyun; Kim, Woon Ji; Kim, Sang Hun; Ha, Bo-Keun

    2017-12-01

    The present study aimed to evaluate the morphological effects of proton beam irradiation on the seed germination, seedling survival, and plant growth of soybean. Seeds of three Korean elite cultivars (Kwangankong, Daepungkong, and Pungsannamulkong) were irradiated with a 57-MeV proton beam in the range of 50 - 400 Gy. The germination rates of all the varieties increased to > 95%; however, the survival rates were significantly reduced. At doses of > 300 Gy irradiation, the Daepungkong, Kwangankong, and Pungsannamulkong cultivars exhibited 39, 75, and 71% survival rates, respectively. In addition, plant height and the fresh weight of shoots and roots were significantly decreased by doses of > 100 Gy irradiation, as were the dry weights of the shoots and roots. However, SPAD values increased with increasing doses of irradiation. Abnormal plants with atypically branched stems, modified leaves, and chlorophyll mutations were observed. Based on the survival rate, plant growth inhibition, and mutation frequency, it appears that the optimum dosage of proton beam irradiation for soybean mutation breeding is between 250 and 300 Gy.

  12. Irradiation of optically activated SI-GaAs high-voltage switches with low and high energy protons

    CERN Document Server

    Bertolucci, Ennio; Mettivier, G; Russo, P; Bisogni, M G; Bottigli, U; Fantacci, M E; Stefanini, A; Cola, A; Quaranta, F; Vasanelli, L; Stefanini, G

    1999-01-01

    Semi-Insulating Gallium Arsenide (SI-GaAs) devices have been tested for radiation hardness with 3-4 MeV or 24 GeV proton beams. These devices can be operated in dc mode as optically activated electrical switches up to 1 kV. Both single switches (vertical Schottky diodes) and multiple (8) switches (planar devices) have been studied, by analyzing their current-voltage (I-V) reverse characteristics in the dark and under red light illumination, both before and after irradiation. We propose to use them in the system of high-voltage (-600 V) switches for the microstrip gas chambers for the CMS experiment at CERN. Low energy protons (3-4 MeV) were used in order to produce a surface damage below the Schottky contact: their fluence (up to 2.6*10/sup 15/ p/cm/sup 2/) gives a high-dose irradiation. The high energy proton irradiation (energy: 24 GeV, fluence: 1.1*10/sup 14/ p/cm/sup 2/) reproduced a ten years long proton exposure of the devices in CMS experiment conditions. For low energy irradiation, limited changes of ...

  13. Effects of a low-energy proton irradiation on n+/p-AlInGaP solar cells

    International Nuclear Information System (INIS)

    Lee, H.S.; Yamaguchi, M.; Ekins-Daukes, N.J.; Khan, A.; Takamoto, T.; Imaizumi, M.; Ohshima, T.; Itoh, H.

    2006-01-01

    For the first time, by deep-level transient spectroscopy, 30keV proton irradiation-induced defects in n + /p-AlInGaP solar cells have been observed. After the 30keV proton irradiation, new deep-level defects such as two majority-carrier (hole) traps HP1 (E V +0.98eV, N T =3.8x10 14 cm -3 ) and HP2, and two minority-carrier (electron) traps EP1 (E C -0.71eV, N T =2.0x10 15 cm -3 ) and EP2 have been observed in p-AlInGaP. The introduction rate of majority-carrier trap center (HP1) is 380cm -1 , which is lower than that (1500cm -1 ) in 100keV proton-irradiated p-InGaP. From the minority-carrier injection annealing for HP1 defect and carrier concentration in 30keV proton-irradiated p-AlInGaP, HP1 defect is likely to act as a recombination center as well as a compensator center

  14. Primary and aggregate color centers in proton irradiated LiF crystals and thin films for luminescent solid state detectors

    Science.gov (United States)

    Piccinini, M.; Ambrosini, F.; Ampollini, A.; Bonfigli, F.; Libera, S.; Picardi, L.; Ronsivalle, C.; Vincenti, M. A.; Montereali, R. M.

    2015-04-01

    Proton beams of 3 MeV energy, produced by the injector of a linear accelerator for proton therapy, were used to irradiate at room temperature lithium fluoride crystals and polycrystalline thin films grown by thermal evaporation. The irradiation fluence range was 1011-1015 protons/cm2. The proton irradiation induced the stable formation of primary and aggregate color centers. Their formation was investigated by optical absorption and photoluminescence spectroscopy. The F2 and F3+ photoluminescence intensities, carefully measured in LiF crystals and thin films, show linear behaviours up to different maximum values of the irradiation fluence, after which a quenching is observed, depending on the nature of the samples (crystals and films). The Principal Component Analysis, applied to the absorption spectra of colored crystals, allowed to clearly identify the formation of more complex aggregate defects in samples irradiated at highest fluences.

  15. Proton irradiation induced defects in Cd and Zn doped InP

    International Nuclear Information System (INIS)

    Rybicki, G.C.; Williams, W.S.

    1993-01-01

    Proton irradiation induced defects in Zn and Cd doped InP have been studied by deep level transient spectroscopy, (DLTS). After 2 MeV proton irradiation the defects H4 and H5 were observed in lightly Zn doped InP, while the defects H3 and H5 were observed in more heavily Zn and Cd doped InP. The defect properties were not affected by the substitution of Cd for Zn, but the introduction rate of H5 was lower in Cd doped InP. The annealing rate of defects was also higher in Cd doped InP. The use of Cd doped InP may thus result in an InP solar cell with even greater radiation resistance

  16. Radiation defects and electron disordering in proton-irradiated diamond films

    International Nuclear Information System (INIS)

    Maschenko, V.E.; Soloviev, G.G.

    1991-01-01

    The absorption spectra are studied in the region of the fundamental absorption band and its longwave boundary for the 0.6 μm thick diamond films deposited onto Al 2 O 3 single crystal underlayers and irradiated by 100 keV and 50 keV protons at fluences of 10 13 -10 16 cm -2 . The E 0 β (6.10-5.9eV) and E 0 α (5.51-5.43eV) maxima and the exponential tails towards lower energies are resolved in the spectra of initial films. The halfwidths of the maxima and a weak temperature dependence of their parameters and of the Urbach tail slope are indicative of disordering of the film structure. The intrinsic maxima near and above the indirect absorption boundary in diamond Γ 25 '-Δ are identified with transitions in the disordered cubic and hexagonal phases of the diamond films. The proton irradiation stimulates the intensity redistribution of the intrinsic maxima, the absorption enhancement, and the change of the Urbach tail slope. The character of radiolysis has been found to depend on the composition of the nonirradiated carbon films and on proton fluence. (author). 8 refs.; 3 figs

  17. The effect of current direction on superconducting properties of BSCCO fibres grown by an electrically assisted laser floating zone process

    International Nuclear Information System (INIS)

    Carrasco, M F; Amaral, V S; Vieira, J M; Silva, R F; Costa, F M

    2006-01-01

    The application of an electric current of 200 mA through the molten zone of BSCCO superconducting fibres during laser floating zone processing constitutes an upgrade for improving the grain alignment. When a direct electric current (positively polarized fibre) passes through the solidification interface, the solidification conditions approach equilibrium, favouring the development of a higher amount of 2212 and 14/24 stable phases. The new electrically assisted laser floating zone (EALFZ) technique also improves the 2223 phase formation in fibres heat treated at high temperatures (860 deg. C). However, the 2223 crystals grow perpendicularly to the fibre axis at the interface between the 2212 and 14/24 phases, crossing the crystals of the main phase responsible for the current transport, cancelling the alignment effect. The resultant current density and critical temperature values were J c 77 K = 230 A cm -2 and T c = 85 K, respectively. When a lower heat treatment temperature was accomplished (820 deg. C), the 2223 transverse crystals do not develop and a higher current density value of J c 77 K = 510 A cm -2 was achieved, although with a critical temperature of T c = 90 K

  18. Radiosensitizing effect of nitric oxide in tumor cells and experimental tumors irradiated with gamma rays and proton beams

    International Nuclear Information System (INIS)

    Policastro, Lucia L.; Duran, Hebe; Molinari, Beatriz L.; Somacal, Hector R.; Valda, Alejandro A.

    2003-01-01

    Nitric oxide (NO) has been reported to be a radiosensitizer of mammalian cells under hypoxic conditions. In a previous study, we demonstrated an enhancement in radiation response induced by NO in mouse tumor cells under aerobic conditions, with an increasing effect as a function of malignancy. The aim of the present study was to evaluate the effect of NO in tumor cells and in experimental tumors irradiated with γ rays and proton beams. Irradiations were performed with a 137 Cs γ source and with proton beams generated by the TANDAR accelerator. Tumor cells were treated with the NO donor DETA-NO and the sensitizer enhancement ratio (SER) was calculated using the α parameter of the survival curve fitted to the linear-quadratic model. Tumor cells irradiated with protons were radio sensitized by DETA-NO only in the more malignant cells irradiated with low LET protons (2.69±0.08 keV/μm). For higher LET protons there were no radiosensitizing effect. For human tumor cells pre-treated with DETA-NO and irradiated with γ rays, a significantly greater effect was demonstrated in the malignant cells (MCF-7) as compared with the near normal cells (HBL-100). Moreover, a significant decrease in tumor growth was demonstrated in mice pre-treated with the NO donor spermine and irradiated with γ rays and low LET protons as compared with mice irradiated without pre-treatment with the NO donor. In conclusion, we demonstrated a differential effect of NO as a radiosensitizer of malignant cells, both with γ rays and low LET protons. This selectivity, coupled to the in vivo inhibition of tumor growth, is of great interest for the potential use of NO releasing agents in radiotherapy. (author)

  19. Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Polf, J C; Peterson, S; Beddar, S [M D Anderson Cancer Center, Univeristy of Texas, Houston, TX 77030 (United States); McCleskey, M; Roeder, B T; Spiridon, A; Trache, L [Cyclotron Institute, Texas A and M University, College Station, TX 77843 (United States)], E-mail: jcpolf@mdanderson.org

    2009-11-21

    In this paper, we present results of initial measurements and calculations of prompt gamma ray spectra (produced by proton-nucleus interactions) emitted from tissue equivalent phantoms during irradiations with proton beams. Measurements of prompt gamma ray spectra were made using a high-purity germanium detector shielded either with lead (passive shielding), or a Compton suppression system (active shielding). Calculations of the spectra were performed using a model of both the passive and active shielding experimental setups developed using the Geant4 Monte Carlo toolkit. From the measured spectra it was shown that it is possible to distinguish the characteristic emission lines from the major elemental constituent atoms (C, O, Ca) in the irradiated phantoms during delivery of proton doses similar to those delivered during patient treatment. Also, the Monte Carlo spectra were found to be in very good agreement with the measured spectra providing an initial validation of our model for use in further studies of prompt gamma ray emission during proton therapy. (note)

  20. Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Meier, D. E-mail: dirk.meier@cern.ch.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Foulon, F.; Friedl, M.; Jany, C.; Gan, K.K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knoepfle, K.T.; Krammer, M.; Manfredi, P.F.; Marshall, R.D.; Mishina, M.; Le Normand, F.; Pan, L.S.; Palmieri, V.G.; Pernegger, H.; Pernicka, M.; Peitz, A.; Pirollo, S.; Pretzl, K.; Re, V.; Riester, J.L.; Roe, S.; Roff, D.; Rudge, A.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R.J.; Tesarek, R.; Thomson, G.B.; Trawick, M.; Trischuk, W.; Turchetta, R.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Ziock, H.; Zoeller, M

    1999-04-21

    CVD diamond shows promising properties for use as a position-sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardness of diamond we exposed CVD diamond detector samples to 24 Gev/c and 500 Mev protons up to a fluence of 5x10{sup 15} p/cm{sup 2}. We measured the charge collection distance, the average distance electron-hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1x10{sup 15} p/cm{sup 2} and decreases by {approx}40% at 5x10{sup 15} p/cm{sup 2}. Leakage currents of diamond samples were below 1 pA before and after irradiation. The particle-induced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage current. We conclude that CVD diamond detectors are radiation hard to 24 GeV/c and 500 MeV protons up to at least 1x10{sup 15}p/cm{sup 2} without signal loss.

  1. High-temperature annealing of proton irradiated beryllium – A dilatometry-based study

    Energy Technology Data Exchange (ETDEWEB)

    Simos, Nikolaos, E-mail: simos@bnl.gov [Brookhaven National Laboratory, Upton, NY, 11973 (United States); Elbakhshwan, Mohamed; Zhong, Zhong; Ghose, Sanjit [Brookhaven National Laboratory, Upton, NY, 11973 (United States); Savkliyildiz, Ilyas [Rutgers University (United States)

    2016-08-15

    S−200 F grade beryllium has been irradiated with 160 MeV protons up to 1.2 10{sup 20} cm{sup −2} peak fluence and irradiation temperatures in the range of 100–200 °C. To address the effect of proton irradiation on dimensional stability, an important parameter in its consideration in fusion reactor applications, and to simulate high temperature irradiation conditions, multi-stage annealing using high precision dilatometry to temperatures up to 740 °C were conducted in air. X-ray diffraction studies were also performed to compliment the macroscopic thermal study and offer a microscopic view of the irradiation effects on the crystal lattice. The primary objective was to qualify the competing dimensional change processes occurring at elevated temperatures namely manufacturing defect annealing, lattice parameter recovery, transmutation {sup 4}He and {sup 3}H diffusion and swelling and oxidation kinetics. Further, quantification of the effect of irradiation dose and annealing temperature and duration on dimensional changes is sought. The study revealed the presence of manufacturing porosity in the beryllium grade, the oxidation acceleration effect of irradiation including the discontinuous character of oxidation advancement, the effect of annealing duration on the recovery of lattice parameters recovery and the triggering temperature for transmutation gas diffusion leading to swelling.

  2. Paramagnetic resonance of LaGaO3: Mn single crystals grown by floating zone melting

    Science.gov (United States)

    Vazhenin, V. A.; Potapov, A. P.; Artyomov, M. Yu.; Salosin, M. A.; Fokin, A. V.; Gil'mutdinov, I. F.; Mukhamedshin, I. R.

    2016-02-01

    The EPR spectrum of Mn-doped lanthanum gallate single crystals grown by floating zone melting with optical heating has been studied. In contrast to the crystals grown according to the Czochralski method, no manganese is found in these crystals even after high-temperature annealing in air. The spectral characteristics of Fe3+ and Gd3+ centers in crystals prepared by various methods have been compared in the rhombohedral phase, and the fourth-rank nondiagonal parameters of the Fe3+ trigonal centers have been determined, as well.

  3. Primary and aggregate color centers in proton irradiated LiF crystals and thin films for luminescent solid state detectors

    International Nuclear Information System (INIS)

    Piccinini, M; Ambrosini, F; Ampollini, A; Bonfigli, F; Libera, S; Picardi, L; Ronsivalle, C; Vincenti, M A; Montereali, R M

    2015-01-01

    Proton beams of 3 MeV energy, produced by the injector of a linear accelerator for proton therapy, were used to irradiate at room temperature lithium fluoride crystals and polycrystalline thin films grown by thermal evaporation. The irradiation fluence range was 10 11 -10 15 protons/cm 2 . The proton irradiation induced the stable formation of primary and aggregate color centers. Their formation was investigated by optical absorption and photoluminescence spectroscopy. The F 2 and F 3 + photoluminescence intensities, carefully measured in LiF crystals and thin films, show linear behaviours up to different maximum values of the irradiation fluence, after which a quenching is observed, depending on the nature of the samples (crystals and films). The Principal Component Analysis, applied to the absorption spectra of colored crystals, allowed to clearly identify the formation of more complex aggregate defects in samples irradiated at highest fluences. (paper)

  4. Effectiveness of proton-beam irradiation of the pituitary gland in children with Itsenko-Cushing disease

    International Nuclear Information System (INIS)

    Zhukovskij, M.A.; Bukhman, A.I.; Levshina, R.B.; Kirpatovskaya, L.E.; Kolesnikova, G.S.; Pankova, S.S.; Lisovets, S.P.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow

    1990-01-01

    The results of the treatment of 20 children with Icenko-Cushing disease (ICD) by proton-beam irradiation of the pituitary glandare presented. The use of the medical proton beam of the Institute of Theoretical and Experimental Physics found to be effective for the treatment of children with mild and average forms of ICD. Irradiation of the pituitary gland at a dose of 70-100 Gy is accompanied by general and local radiation reactions which are not dangerous for children. The time of development of remission after irradiation depends on a degree of severity and features of a course of disease

  5. Formation cross-sections and chromatographic separation of protactinium isotopes formed in proton-irradiated thorium metal

    Energy Technology Data Exchange (ETDEWEB)

    Radchenko, Valery; Engle, Jonathan W.; Wilson, Justin J.; Maassen, Joel R.; Nortier, Meiring F.; Birnbaum, Eva R.; John, Kevin D.; Fassbender, Michael E. [Los Alamos National Laboratory, NM (United States)

    2016-08-01

    Targeted alpha therapy (TAT) is a treatment method of increasing interest to the clinical oncology community that utilizes α-emitting radionuclides conjugated to biomolecules for the selective killing of tumor cells. Proton irradiation of thorium generates a number of α-emitting radionuclides with therapeutic potential for application via TAT. In particular, the radionuclide {sup 230}Pa is formed via the {sup 232}Th(p, 3n) nuclear reaction and partially decays to {sup 230}U, an α emitter which has recently received attention as a possible therapy nuclide. In this study, we estimate production yields for {sup 230}Pa and other Pa isotopes from proton-irradiated thorium based on cross section measurements. We adopt existing methods for the chromatographic separation of protactinium isotopes from proton irradiated thorium matrices to combine and optimize them for effective fission product decontamination.

  6. Fractionated proton beam irradiation of pituitary adenomas

    International Nuclear Information System (INIS)

    Ronson, Brian B.; Schulte, Reinhard W.; Han, Khanh P.; Loredo, Lilia N.; Slater, James M.; Slater, Jerry D.

    2006-01-01

    Purpose: Various radiation techniques and modalities have been used to treat pituitary adenomas. This report details our experience with proton treatment of these tumors. Methods and Materials: Forty-seven patients with pituitary adenomas treated with protons, who had at least 6 months of follow-up, were included in this analysis. Forty-two patients underwent a prior surgical resection; 5 were treated with primary radiation. Approximately half the tumors were functional. The median dose was 54 cobalt-gray equivalent. Results: Tumor stabilization occurred in all 41 patients available for follow-up imaging; 10 patients had no residual tumor, and 3 had greater than 50% reduction in tumor size. Seventeen patients with functional adenomas had normalized or decreased hormone levels; progression occurred in 3 patients. Six patients have died; 2 deaths were attributed to functional progression. Complications included temporal lobe necrosis in 1 patient, new significant visual deficits in 3 patients, and incident hypopituitarism in 11 patients. Conclusion: Fractionated conformal proton-beam irradiation achieved effective radiologic, endocrinological, and symptomatic control of pituitary adenomas. Significant morbidity was uncommon, with the exception of postradiation hypopituitarism, which we attribute in part to concomitant risk factors for hypopituitarism present in our patient population

  7. Optical and electrical properties of some electron and proton irradiated polymers

    International Nuclear Information System (INIS)

    Mishra, R.; Tripathy, S.P.; Sinha, D.; Dwivedi, K.K.; Ghosh, S.; Khathing, D.T.; Mueller, M.; Fink, D.; Chung, W.H.

    2000-01-01

    Ion beam treatment studies have been carried out to investigate the potential for improvements in conductivity properties of the polymers Polytetrafluroethylene (PTFE), Polyimide (PI), Polyethyleneterepthalate (PET) and Polypropylene (PP), after 2 MeV electron and 62 MeV proton irradiation. The shift in optical absorption edges as observed by UV-VIS spectra of the irradiated polymers has been correlated to the optical band-gap using Tauc's expression. A decrease in the optical band-gap has been observed in irradiated PP and PTFE, but no considerable change was found for the optical band-gaps of PET and PI. Further AC conductivity measurements confirmed an increase in conductivity in electron irradiated PP

  8. Proton irradiation of a swept charge device at cryogenic temperature and the subsequent annealing

    International Nuclear Information System (INIS)

    Gow, J P D; Smith, P H; Hall, D J; Holland, A D; Murray, N J; Pool, P

    2015-01-01

    A number of studies have demonstrated that a room temperature proton irradiation may not be sufficient to provide an accurate estimation of the impact of the space radiation environment on detector performance. This is a result of the relationship between defect mobility and temperature, causing the performance to vary subject to the temperature history of the device from the point at which it was irradiated. Results measured using Charge Coupled Devices (CCD) irradiated at room temperature therefore tend to differ from those taken when the device was irradiated at a cryogenic temperature, more appropriate considering the operating conditions in space, impacting the prediction of in-flight performance. This paper describes the cryogenic irradiation, and subsequent annealing of an e2v technologies Swept Charge Device (SCD) CCD236 irradiated at −35.4°C with a 10 MeV equivalent proton fluence of 5.0 × 10 8 protons · cm −2 . The CCD236 is a large area (4.4 cm 2 ) X-ray detector that will be flown on-board the Chandrayaan-2 and Hard X-ray Modulation Telescope spacecraft, in the Chandrayaan-2 Large Area Soft X-ray Spectrometer and the Soft X-ray Detector respectively. The SCD is readout continually in order to benefit from intrinsic dither mode clocking, leading to suppression of the surface component of the dark current and allowing the detector to be operated at warmer temperatures than a conventional CCD. The SCD is therefore an excellent choice to test and demonstrate the variation in the impact of irradiation at cryogenic temperatures in comparison to a more typical room temperature irradiation

  9. Dose determination of 600 MeV proton irradiated specimens

    International Nuclear Information System (INIS)

    Gavillet, D.

    1991-01-01

    The calculation method for the experimental determination of the atomic production cross section from the γ activity measurements are presented. This method is used for the determination of some isotope production cross sections for 600 MeV proton irradition in MANET steel, copper, tungsten, gold and titanium. The results are compared with some calculation. These values are used to determine the dose of specimens irradiated in the PIREX II facility. The results are discussed in terms of the irradiation parameters. A guide for the use of the production cross section determined in the dosimetry experiment are given. (author) tabs., refs

  10. Refractive index depth profile in PMMA due to proton irradiation

    International Nuclear Information System (INIS)

    Szilasi, S.Z.; Rajta, I.; Budai, J.; Toth, Z.; Petrik, P.; Baradacs, E.

    2006-01-01

    Complete text of publication follows. During Proton Beam Writing the beam damage causes chain scissioning in the polymer resist material (e.g. PMMA (Polymethyl methacrylate)), producing smaller molecular weight chains. Hydrogen implantation also takes place at the end of range. Compaction of the sample has been observed too, which means that the sample density becomes higher at the places where proton irradiation occurred. Furthermore, P-beam Writing has been successfully used to create buried channel waveguides in PMMA [1], since proton irradiation increases the refractive index. There are two ways of fabricating waveguides using P-beam Writing, one of them applies direct micromachining of the high refractive index core followed by the coating of a lower refractive index cladding layer. In this application the refractive indices of the substrate, the core and the cladding have to be known, which should be homogeneous within the whole structure. The other method allows producing buried waveguides. In this case proton beam writing is used to modify the refractive index along the ion path in the sample, where most of the ion energy is deposited near the end of range also known as the Bragg peak. For polymers 10 -3 refractive index change has been reported, which is usually sufficient for forming waveguides. Those measurements of the refractive index change have been performed by the refracted near field technique. In this work we used ellipsometry, in order to measure the optical parameters of the P-beam treated sample near the surface, and along the Bragg curve. Ellipsometry measures the change in the polarization state of light occurring during reflection. This change is related to the quality of the reflecting surface (i.e. the physical structure, layer thicknesses, optical constants, surface roughness, etc.). >From these measurements the refractive index and the extinction coefficient can be determined rather accurately, which makes ellipsometry a powerful tool

  11. Photocarrier Radiometry for Non-contact Evaluation of Monocrystalline Silicon Solar Cell Under Low-Energy (< 200 keV) Proton Irradiation

    Science.gov (United States)

    Oliullah, Md.; Liu, J. Y.; Song, P.; Wang, Y.

    2018-06-01

    A three-layer theoretical model is developed for the characterization of the electronic transport properties (lifetime τ, diffusion coefficient D, and surface recombination velocity s) with energetic particle irradiation on solar cells using non-contact photocarrier radiometry. Monte Carlo (MC) simulation is carried out to obtain the depth profiles of the proton irradiation layer at different low energies (solar cells are investigated under different low-energy proton irradiation, and the carrier transport parameters of the three layers are obtained by best-fitting of the experimental results. The results show that the low-energy protons have little influence on the transport parameters of the non-irradiated layer, but high influences on both of the p and n-region irradiation layers which are consisted of MC simulation.

  12. Proton and Neutron Irradiation Tests of Readout Electronics of the ATLAS Hadronic Endcap Calorimeter

    CERN Document Server

    Menke, Sven; The ATLAS collaboration

    2012-01-01

    The readout electronics of the ATLAS Hadronic Endcap Calorimeter will have to withstand the about ten times larger radiation environment of the future high-luminosity LHC (HL-LHC) compared to their design values. The GaAs ASIC which comprises the heart of the readout electronics has been exposed to neutron and proton radiation with fluences up to ten times the total expected fluences for ten years of running of the HL-LHC. Neutron tests where performed at the NPI in Rez, Czech Republic, where a 36 MeV proton beam is directed on a thick heavy water target to produce neutrons. The proton irradiation was done with 200 MeV protons at the PROSCAN area of the Proton Irradiation Facility at the PSI in Villigen, Switzerland. In-situ measurements of S-parameters in both tests allow the evaluation of frequency dependent performance parameters - like gain and input impedance - as a function of the fluence. The linearity of the ASIC response has been measured directly in the neutron tests with a triangular input pulse of...

  13. Proton and Neutron Irradiation Tests of Readout Electronics of the ATLAS Hadronic Endcap Calorimeter

    CERN Document Server

    INSPIRE-00106910

    2012-01-01

    The readout electronics of the ATLAS Hadronic Endcap Calorimeter will have to withstand the about ten times larger radiation environment of the future high-luminosity LHC (HL-LHC) compared to their design values. The GaAs ASIC which comprises the heart of the readout electronics has been exposed to neutron and proton radiation with fluences up to ten times the total expected fluences for ten years of running of the HL-LHC. Neutron tests were performed at the NPI in Rez, Czech Republic, where a 36 MeV proton beam is directed on a thick heavy water target to produce neutrons. The proton irradiation was done with 200 MeV protons at the PROSCAN area of the Proton Irradiation Facility at the PSI in Villigen, Switzerland. In-situ measurements of S-parameters in both tests allow the evaluation of frequency dependent performance parameters - like gain and input impedance - as a function of the fluence. The linearity of the ASIC response has been measured directly in the neutron tests with a triangular input pulse of ...

  14. Radiosensitization by PARP inhibition to proton beam irradiation in cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Hirai, Takahisa [Department of Radiation Oncology, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo (Japan); Division of Chemotherapy and Clinical Cancer Research, National Cancer Center Research Institute, Chuo-ku, Tokyo (Japan); Saito, Soichiro; Fujimori, Hiroaki [Division of Chemotherapy and Clinical Cancer Research, National Cancer Center Research Institute, Chuo-ku, Tokyo (Japan); Matsushita, Keiichiro; Nishio, Teiji [Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima-shi, Hiroshima (Japan); Okayasu, Ryuichi [International Open Laboratory, National Institute of Radiological Science, Chiba-shi, Chiba (Japan); Masutani, Mitsuko, E-mail: mmasutan@nagasaki-u.ac.jp [Division of Chemotherapy and Clinical Cancer Research, National Cancer Center Research Institute, Chuo-ku, Tokyo (Japan); Department of Frontier Life Sciences, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki (Japan)

    2016-09-09

    The poly(ADP-ribose) polymerase (PARP)-1 regulates DNA damage responses and promotes base excision repair. PARP inhibitors have been shown to enhance the cytotoxicity of ionizing radiation in various cancer cells and animal models. We have demonstrated that the PARP inhibitor (PARPi) AZD2281 is also an effective radiosensitizer for carbon-ion radiation; thus, we speculated that the PARPi could be applied to a wide therapeutic range of linear energy transfer (LET) radiation as a radiosensitizer. Institutes for biological experiments using proton beam are limited worldwide. This study was performed as a cooperative research at heavy ion medical accelerator in Chiba (HIMAC) in National Institute of Radiological Sciences. HIMAC can generate various ion beams; this enabled us to compare the radiosensitization effect of the PARPi on cells subjected to proton and carbon-ion beams from the same beam line. After physical optimization of proton beam irradiation, the radiosensitization effect of the PARPi was assessed in the human lung cancer cell line, A549, and the pancreatic cancer cell line, MIA PaCa-2. The effect of the PARPi, AZD2281, on radiosensitization to Bragg peak was more significant than that to entrance region. The PARPi increased the number of phosphorylated H2AX (γ-H2AX) foci and enhanced G2/M arrest after proton beam irradiation. This result supports our hypothesis that a PARPi could be applied to a wide therapeutic range of LET radiation by blocking the DNA repair response. - Highlights: • Effective radiosensitizers for particle radiation therapy have not been reported. • PARP inhibitor treatment radiosensitized after proton beam irradiation. • The sensitization at Bragg peak was greater than that at entrance region. • DSB induction and G2/M arrest is involved in the sensitization mechanism.

  15. Electric dipole moment in KH{sub 2}PO{sub 4} systematically modified by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Jin Kweon, Jung; Lee, Cheol Eui [Department of Physics and Institute for Nano Science, Korea University, Seoul 136-713 (Korea, Republic of); Noh, S. J.; Kim, H. S. [Department of Applied Physics, Dankook University, Yongin 448-701 (Korea, Republic of)

    2012-01-01

    We have carried out an impedance spectroscopy study on a series of proton-irradiated KH{sub 2}PO{sub 4} (KDP) systems. A systematic modification was observed in the transverse dipole moment of the proton-irradiated KDP systems, associated with hydrogen-ion displacements, as obtained from dielectric constant measurements by using a mean-field approximation. Besides, intercorrelation of the charge transport with the dielectric properties was revealed, both having closely to do with the hydrogen-bond modification.

  16. Influence of reactor irradiation on the protons intercalation and stability of barium cerates and strontium cerates

    International Nuclear Information System (INIS)

    Aksenova, T.I.; Khromushin, I.V.; Zhotabaev, Zh.R.; Kornienko, P.A.; Munasbaeva, K.K.

    2005-01-01

    The work is devoted to study of reactor irradiation influence on the gas-solid exchange processes in the high-temperature proton semiconductors on the base of cerates and strontium. A number of new regularities of influence of content of some proton semiconductors on the gas-solid exchange processes was established. It is shown, that increase of rate of cation doping rate leads to considerable lowering in its of carbonic gas content, and therefore to improvement their tribological properties. It is revealed, that irradiation of polycrystalline samples leads to growth of oxygen amount desorbed from samples, whereas irradiation of monocrystalline samples practically does not has effect on the desorbed oxygen amount. It was found, that character of relation of intercalated in the sample protons depend on sample doping rate

  17. Response of thyroid follicular cells to gamma irradiation compared to proton irradiation: II. The role of connexin 32

    Science.gov (United States)

    Green, L. M.; Tran, D. T.; Murray, D. K.; Rightnar, S. S.; Todd, S.; Nelson, G. A.

    2002-01-01

    The objective of this study was to determine whether connexin 32-type gap junctions contribute to the "contact effect" in follicular thyrocytes and whether the response is influenced by radiation quality. Our previous studies demonstrated that early-passage follicular cultures of Fischer rat thyroid cells express functional connexin 32 gap junctions, with later-passage cultures expressing a truncated nonfunctional form of the protein. This model allowed us to assess the role of connexin 32 in radiation responsiveness without relying solely on chemical manipulation of gap junctions. The survival curves generated after gamma irradiation revealed that early-passage follicular cultures had significantly lower values of alpha (0.04 Gy(-1)) than later-passage cultures (0.11 Gy(-1)) (P 0.1, n = 9). This strongly suggests that the presence of functional connexin 32-type gap junctions was contributing to radiation resistance in gamma-irradiated thyroid follicles. Survival curves from proton-irradiated cultures had alpha values that were not significantly different whether cells expressed functional connexin 32 (0.10 Gy(-1)), did not express connexin 32 (0.09 Gy(-1)), or were down-regulated (early-passage plus heptanol, 0.09 Gy(-1); late-passage plus heptanol, 0.12 Gy(-1)) (P > 0.1, n = 19). Thus, for proton irradiation, the presence of connexin 32-type gap junctional channels did not influence their radiosensitivity. Collectively, the data support the following conclusions. (1) The lower alpha values from the gamma-ray survival curves of the early-passage cultures suggest greater repair efficiency and/or enhanced resistance to radiation-induced damage, coincident with the expression of connexin 32-type gap junctions. (2) The increased sensitivity of FRTL-5 cells to proton irradiation was independent of their ability to communicate through connexin 32 gap junctions. (3) The fact that the beta components of the survival curves from both gamma rays and proton beams were

  18. Slow-positron annihilation analysis on optical degradation of ZnO white paint irradiated by protons

    International Nuclear Information System (INIS)

    Xiao Haiying; Li Chundong; Yang Dezhuang; He Shiyu; Jia Jin; Ye Bangjiao

    2009-01-01

    The optical degradation in ZnO white paint under low energy proton exposure was investigated in terms of slow-positron annihilation spectroscopy. Experimental results show that with increasing proton fluence, the S-parameter of the Doppler broadening spectrum gradually decreases, and the W-parameter increases.The slope plot of the fitting S-W changes under the proton exposure. The decrease of S-parameter can be attributed to a decrease of zinc vacancy content and the formation of quasi-positronium. The quasi-positronium is viewed as a bounded state of a singly ionized oxygen vacancy (trapping an electron) with a positron, the formation of which could reduce the positron annihilation rate and thus the S-parameter. The decrease of S-parameter demonstrates the amount increase of singly ionized oxygen vacancy of ZnO white paint caused by proton irradiation. The change of the S-Wplot slope is related to the transformation of doubly ionized oxygen vacancies into singly ionized oxygen vacancies under proton irradiation. (authors)

  19. Hydrogen Release From 800-MeV Proton-Irradiated Tungsten

    International Nuclear Information System (INIS)

    Oliver, Brian M.; Venhaus, Thomas J.; Causey, Rion A.; Garner, Francis A.; Maloy, Stuart A.

    2002-01-01

    Tungsten irradiated in spallation neutron sources such as those proposed for the Accelerator Production of Tritium (APT) project, or in proposed fusion reactors, will contain large quantities of generated helium and hydrogen gas. In the APT, spallation neutrons would be generated by the interaction of high energy (∼1 GeV) protons with solid tungsten rods or cylinders. In fusion reactors, tungsten used in a tokamak diverter will contain hydrogen, as well as deuterium and tritium diffusing in from the plasma-facing surface. The release kinetics of these gases during various off-normal scenarios involving loss of coolant and afterheat-induced rises in temperature is of particular interest for both applications. To determine the release kinetics of hydrogen from tungsten, tungsten rods irradiated with 800 MeV protons in the Los Alamos Neutron Science Center (LANCE) to high exposures as part of the APT project have been examined. Hydrogen evolution from the tungsten was measured using a dedicated mass spectrometer system by subjecting the specimens to an essentially linear temperature ramp from ∼323 K to ∼1473 K. Release profiles are compared with predictions obtained using the Tritium Migration Analysis Program (TMAP4). Input parameters for the modeling, consisting of diffusivity, recombination rate coefficient, and trapping, are discussed. The measurements show that for high proton doses, the majority of the hydrogen is released gradually, starting at about 900 K and reaching a maximum at about 1400 K, where it drops fairly rapidly. Comparisons with TMAP show reasonable agreement at high proton dose using a trap value of 1.4 eV and a trap density of 3%. There is also a small release fraction occurring at ∼600 K which predominates at lower proton doses, and which is relatively independent of dose. This lower-temperature release is predicted by TMAP if no traps are assumed, suggesting that this release may represent an adsorbed surface component

  20. Raman spectroscopic study on sodium hyaluronate: an effect of proton and gamma irradiation

    Czech Academy of Sciences Publication Activity Database

    Synytsya, A.; Alexa, P.; Wagner, Richard; Davídková, Marie; Volka, K.

    2011-01-01

    Roč. 42, č. 3 (2011), s. 544-550 ISSN 0377-0486 Institutional research plan: CEZ:AV0Z10480505 Keywords : sodium hyaluronate * proton irradiation * gamma irradiation * Raman spectroscopy Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.087, year: 2011 http://onlinelibrary.wiley.com/doi/10.1002/jrs.2724/full

  1. Mechanical properties of low temperature proton irradiated single crystal copper

    International Nuclear Information System (INIS)

    Schildcrout, M.

    1975-01-01

    Single crystal copper samples, of varying degrees of cold work, were irradiated near either liquid helium or liquid nitrogen temperature by 10.1-MeV protons. The internal friction and dynamic Young's modulus were observed as a function of either temperature or integrated proton flux. The primary effect of irradiation was to produce dislocation pinning. The initial pinning rate was found to be very sensitive to cold work. During irradiation it was found that heavily cold worked samples (25 percent compression) exhibited, almost exclusively, exponential pinning given by Y = e/sup --lambda phi/. This is attributed to the immobilization, rather than shortening, of loop lengths and is characterized by the pinning constant lambda. Exponential pinning was also found, to a smaller degree, in less heavily cold worked samples. Cold work appears to reduce the ''effective volume'' within which the defect clusters produced by irradiation, can immobilize dislocation segments. The bulk effect was observed after dislocation pinning was completed. Expressed in terms of the fractional change in Young's modulus per unit concentration of irradiation induced defects, it was measured at liquid helium temperature to be --18.5 +- 3. An anelastic process occurring near 10 0 K for low kHz frequencies and due to stress-induced ordering of point defects produced by irradiation has also been studied. The peak height per unit fluence was found to decrease with increasing cold work. The peak was not observed in samples compressed 25 percent. For the most carefully handled sample the activation energy was (1.28 +- 0.05) x 10 -2 eV, the attempt frequency was 10/sup 11.6 +- .8/ s -1 , the shape factor was 0.20, and the half width of the peak was 11 percent larger than the theoretical value calculated from the Debye equation for a single relaxation process

  2. A New High-intensity Proton Irradiation Facility at the CERN PS East Area

    CERN Document Server

    Gkotse, B; Lima, P; Matli, E; Moll, M; Ravotti, F

    2014-01-01

    and IRRAD2), were heavily and successfully used for irradiation of particle detectors, electronic components and materials since 1992. These facilities operated with particle bursts - protons with momentum of 24GeV/c - delivered from the PS accelerator in “spills” of about 400ms (slow extraction). With the increasing demand of irradiation experiments, these facilities suffered from a number of restrictions such as the space availability, the maximum achievable particle flux and several access constraints. In the framework of the AIDA project, an upgrade of these facilities has been realized during the CERN long shutdown (LS1). While the new proton facility (IRRAD) will continue to be mainly devoted to the radiation hardness studies for the High Energy Physics (HEP) experimental community, the new mixed-field facility (CHARM) will mainly host irradiation experiments for the validation of electronic systems used in a...

  3. The RADEX facility as a tool for studies of radiation damage under proton and spallation neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Koptelov, E.A.; Lebedev, S.G.; Matveev, V.A.; Sobolevsky, N.M. [Institute for Nuclear Research of Russian Academy of Sciences, Moscow (Russian Federation); Strebkov, Yu.S.; Subbotin, A.V. [Research and Development Institute of Power Engineering, Moscow (Russian Federation)

    2001-03-01

    We present results of numerical modeling for processes of primary protons and spallation neutrons interactions with structural materials at the RADiation EXperiment facility of the Neutron Complex. The installation has a vertical irradiation channel inside the beam stop for horizontally incident protons with energies up to 600 MeV of the Moscow Meson Factory of the INR (Institute for Nuclear Research) RAS (Russian Academy of Science). The calculations are based on a set of computer codes SHIELD and RADDAM, which were developed in the INR RAS and give data on point defect generation by irradiation, rate of accumulation of H and He atoms produced in nuclear reactions, energetic spectra of primary knocked-off atoms in collision displacements, temperature of samples under irradiation. Different positions of the channel, which are available by rotation of a target relatively the vertical axis for angles 0, 60, 120 and 180 degrees to the proton beam direction, are considered. Changes of irradiation damage parameters due to various inputs of primary protons and spallation neutrons at different target orientations are demonstrated. It is shown also that the spallation neutron facility RADEX may provide with perspective experimental possibilities for modeling of irradiation conditions for fusion reactors ITER and DEMO. (author)

  4. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    Science.gov (United States)

    Gencer, A.; Demirköz, B.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-07-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between 10 μA and 1.2 mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam flux. The DBL is designed to provide fluxes between 107 p /cm2 / s and 109 p /cm2 / s for performing irradiation tests in an area of 15.4 cm × 21.5 cm. The facility will be the first irradiation facility of its kind in Turkey.

  5. Differential gene expression in primary fibroblasts induced by proton and cobalt-60 beam irradiation

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Bassler, Niels; Grzanka, Leszek

    2017-01-01

    profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis...... and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated...... fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy....

  6. Creation of 3D microsculptures in PMMA by multiple angle proton irradiation

    International Nuclear Information System (INIS)

    Andrea, T.; Rothermel, M.; Reinert, T.; Koal, T.; Butz, T.

    2011-01-01

    In recent years the technique of proton beam writing has established itself as a versatile method for the creation of microstructures in resist materials. While these structures can be almost arbitrary in two dimensions, the creation of genuine 3D structures remains a challenge. At the LIPSION accelerator facility a new approach has been developed which combines aspects of ion beam tomography, so far solely an analysis method, with proton beam writing. Key element is the targeted irradiation from multiple angles in order to obtain a much broader range of 3D microstructures than has hitherto been possible. PMMA columns with a diameter of ∼90 μm were used as raw material and placed in an upright position on top of a rotational axis. Using 2.25 MeV protons patterns corresponding to the silhouettes of the desired structures were written from two or more directions. In a subsequent step of chemical etching irradiated portions were dissolved, leaving behind the finished 3D sculpture. Various objects have been created. For the demonstration of the method a 70 μm high model of the Eiffel tower has been sculpted by irradiation from two angles. Using irradiation from three angles a 40 μm wide screw with right-handed thread could be crafted which might find applications in micromachining. Also, a cage structure with a pore size of ca. 20 μm was written with the intention to use it as a scaffold for the growth of biological cells.

  7. Resistivity changes in superconducting-cavity-grade Nb following high-energy proton irradiation

    International Nuclear Information System (INIS)

    Snead, C.L. Jr.; Hanson, A.; Greene, G.A.

    1997-01-01

    Niobium superconducting rf cavities are proposed for use in the proton LINAC accelerators for spallation-neutron applications. Because of accidental beam loss and continual halo losses along the accelerator path, concern for the degradation of the superconducting properties of the cavities with accumulating damage arises. Residual-resistivity-ratio (RRR) specimens of Nb, with a range of initial RRR's were irradiated at room temperature with protons at energies from 200 to 2000 MeV. Four-probe resistance measurements were made at room temperature and at 4.2 K both prior to and after irradiation. Nonlinear increases in resistivity simulate expected behavior in cavity material after extended irradiation, followed by periodic anneals to room temperature: For RRR = 316 material, irradiations to (2 - 3) x 10 15 p/cm 2 produce degradations up to the 10% level, a change that is deemed operationally acceptable. Without. periodic warming to room temperature, the accumulated damage energy would be up to a factor of ten greater, resulting in unacceptable degradations. Likewise, should higher-RRR material be used, for the same damage energy imparted, relatively larger percentage changes in the RRR will result

  8. Proton irradiation augments the reduction in tumor progression observed with advanced age

    Data.gov (United States)

    National Aeronautics and Space Administration — Proton irradiation is touted for its improved tumor targeting due to the physical advantages of ion beams for radiotherapy. Recent studies from our laboratory have...

  9. Radiation hardness of silicon detectors manufactured on wafers from various sources

    International Nuclear Information System (INIS)

    Dezillie, B.; Bates, S.; Glaser, M.; Lemeilleur, F.; Leroy, C.

    1997-01-01

    Impurity concentrations in the initial silicon material are expected to play an important role for the radiation hardness of silicon detectors, during their irradiation and for their evolution with time after irradiation. This work reports on the experimental results obtained with detectors manufactured using various float-zone (FZ) and epitaxial-grown material. Preliminary results comparing the changes in leakage current and full depletion voltage of FZ and epitaxial detectors as a function of fluence and of time after 10 14 cm -2 proton irradiation are given. The measurement of charge collection efficiency for epitaxial detectors is also presented. (orig.)

  10. The comparison of microstructure and nanocluster evolution in proton and neutron irradiated Fe–9%Cr ODS steel to 3 dpa at 500 °C

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, M.J., E-mail: matthewswenson1@u.boisestate.edu; Wharry, J.P.

    2015-12-15

    A model Fe–9%Cr oxide dispersion strengthened (ODS) steel was irradiated with protons or neutrons to a dose of 3 displacements per atom (dpa) at a temperature of 500 °C, enabling a direct comparison of ion to neutron irradiation effects at otherwise fixed irradiation conditions. The irradiated microstructures were characterized using transmission electron microscopy and atom probe tomography including cluster analysis. Both proton and neutron irradiations produced a comparable void and dislocation loop microstructure. However, the irradiation response of the Ti–Y–O oxide nanoclusters varied. Oxides remained stable under proton irradiation, but exhibited dissolution and an increase in Y:Ti composition ratio under neutron irradiation. Both proton and neutron irradiation also induced varying extents of Si, Ni, and Mn clustering at existing oxide nanoclusters. Protons are able to reproduce the void and loop microstructure of neutron irradiation carried out to the same dose and temperature. However, since nanocluster evolution is controlled by both diffusion and ballistic impacts, protons are rendered unable to reproduce the nanocluster evolution of neutron irradiation at the same dose and temperature. - Highlights: • Fe–9% Cr ODS was irradiated with protons and neutrons to 3 dpa at 500 °C. • Dislocation loop size and density were similar upon proton and neutron irradiation. • Oxide nanocluster size and density decreased more with neutron irradiation. • Oxide Y:Ti ratio increased from 0.54 to 0.97 upon neutron irradiation. • Irradiation induced enrichment of Si, Mn, and Ni at oxide locations.

  11. Correlations for damage in diffused-junction InP solar cells induced by electron and proton irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Takamoto, T.; Taylor, S.J.; Walters, R.J.; Summers, G.P.; Flood, D.J.; Ohmori, M.

    1997-01-01

    The damage to diffused-junction n + -p InP solar cells induced by electron and proton irradiations over a wide range of energy from 0.5 to 3 MeV and 0.015 to 20 MeV, respectively, has been examined. The experimental electron and proton damage coefficients have been analyzed in terms of displacement damage dose, which is the product of the particle fluence and the calculated nonionizing energy loss [G. P. Summers, E. A. Burke, R. Shapiro, S. R. Messenger, and R. J. Walters, IEEE Trans. Nucl. Sci. 40, 1300 (1993).] Degradation of InP cells due to irradiation with electrons and protons with energies of more than 0.5 MeV show a single curve as a function of displacement damage dose. Based on the deep-level transient spectroscopy analysis, damage equivalence between electron and proton irradiation is discussed. InP solar cells are confirmed to be substantially more radiation resistant than Si and GaAs-on-Ge cells. copyright 1997 American Institute of Physics

  12. Proton Irradiation of CVD Diamond Detectors for High Luminosity Experiments at the LHC

    CERN Document Server

    Meier, D; Bauer, C; Berdermann, E; Bergonzo, P; Bogani, F; Borchi, E; Bruzzi, Mara; Colledani, C; Conway, J; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Grigoriev, E A; Hallewell, G D; Hall-Wilton, R; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Jany, C; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Knöpfle, K T; Krammer, Manfred; Manfredi, P F; Marshall, R D; Mishina, M; Le Normand, F; Pan, L S; Palmieri, V G; Pernegger, H; Pernicka, Manfred; Peitz, A; Pirollo, S; Pretzl, Klaus P; Re, V; Riester, J L; Roe, S; Roff, D G; Rudge, A; Schnetzer, S R; Sciortino, S; Speziali, V; Stelzer, H; Stone, R; Tapper, R J; Tesarek, R J; Thomson, G B; Trawick, M L; Trischuk, W; Turchetta, R; Walsh, A M; Wedenig, R; Weilhammer, Peter; Ziock, H J; Zöller, M

    1999-01-01

    CVD diamond shows promising properties for use as a position sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardn ess of diamond we exposed CVD diamond detector samples to 24~GeV/$c$ and 500~MeV protons up to a fluence of $5\\times 10^{15}~p/{\\rm cm^2}$. We measured the charge collection distance, the ave rage distance electron hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to $1\\ times 10^{15}~p/{\\rm cm^2}$ and decreases by $\\approx$40~\\% at $5\\times 10^{15}~p/{\\rm cm^2}$. Leakage currents of diamond samples were below 1~pA before and after irradiation. The particle indu ced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage curren t. We conclude that CVD diamond detectors are radia...

  13. Ionization versus displacement damage effects in proton irradiated CMOS sensors manufactured in deep submicron process

    International Nuclear Information System (INIS)

    Goiffon, V.; Magnan, P.; Saint-Pe, O.; Bernard, F.; Rolland, G.

    2009-01-01

    Proton irradiation effects have been studied on CMOS image sensors manufactured in a 0.18μm technology dedicated to imaging. The ionizing dose and displacement damage effects were discriminated and localized thanks to 60 Co irradiations and large photodiode reverse current measurements. The only degradation observed was a photodiode dark current increase. It was found that ionizing dose effects dominate this rise by inducing generation centers at the interface between shallow trench isolations and depleted silicon regions. Displacement damages are is responsible for a large degradation of dark current non-uniformity. This work suggests that designing a photodiode tolerant to ionizing radiation can mitigate an important part of proton irradiation effects.

  14. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

    Science.gov (United States)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-09-07

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from (12)C (4.44 MeV) and (16)O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10(7) oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from (16)O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring (16)O PG emission.

  15. Application of the Moessbauer spectroscopy to the investigation of the proton irradiation effects in several iron compounds

    International Nuclear Information System (INIS)

    Kopcewicz, M.; Kotlicki, A.

    1975-01-01

    The results of a study into the influence of proton irradiation on the Moessbauer effect in FeSO 4 x 7H 2 O, K 4 [Fe(CN) 6 ] x 3H 2 O and K 3 [Fe(CN) 6 ] are reported. In the interpretation of the effect observed, the 'spike' model was applied. Chemical decomposition processes due to proton irradiation and formation of the superparamagnetic state of metallic iron were investigated. A Moessbauer observation of interstitial Fe 2+ ions in irradiated FeSO 4 x 7H 2 O was made. (Z.S.)

  16. Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

    Science.gov (United States)

    Zhang, Z.; Cardwell, D.; Sasikumar, A.; Kyle, E. C. H.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; Speck, J. S.; Arehart, A. R.; Ringel, S. A.

    2016-04-01

    The impact of proton irradiation on the threshold voltage (VT) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of VT was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 1014 cm-2. Silvaco Atlas simulations of VT shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different VT dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed VT shifts. The proton irradiation induced VT shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.

  17. TiO2-PANI/Cork composite: A new floating photocatalyst for the treatment of organic pollutants under sunlight irradiation.

    Science.gov (United States)

    Sboui, Mouheb; Nsib, Mohamed Faouzi; Rayes, Ali; Swaminathan, Meenakshisundaram; Houas, Ammar

    2017-10-01

    A novel photocatalyst based on TiO 2 -PANI composite supported on small pieces of cork has been reported. It was prepared by simple impregnation method of the polyaniline (PANI)-modified TiO 2 on cork. The TiO 2 -PANI/Cork catalyst shows the unique feature of floating on the water surface. The as-synthesized catalyst was characterized by X-ray diffraction (XRD), scanning electron micrograph (SEM), transmission electron microscopy (TEM), thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FT-IR), UV-vis diffuse reflectance spectra (UV-vis DRS) and the Brunauer-Emmett-Teller (BET) surface area analysis. Characterization suggested the formation of anatase highly dispersed on the cork surface. The prepared floating photocatalyst showed high efficiency for the degradation of methyl orange dye and other organic pollutants under solar irradiation and constrained conditions, i.e., no-stirring and no-oxygenation. The TiO 2 -PANI/Cork floating photocatalyst can be reused for at least four consecutive times without significant decrease of the degradation efficiency. Copyright © 2017. Published by Elsevier B.V.

  18. Enhancements of the critical currents of YBaCuO single crystals by neutron (n) and proton (p) irradiation

    International Nuclear Information System (INIS)

    Vlcek, B.M.; Frischherz, M.C.; Vishwanathan, H.K.; Welp, U.; Crabtree, G.W.; Kirk, M.A.

    1992-01-01

    We present results of magnetization hysteresis and T c measurements of neutron and proton irradiated YBaCuO single crystals. The crystals used for comparison were irradiated to a fluence of 2x10 7 n/cm 2 (n,E > 0.1MeV) and 1x10 16 p/cm 2 (p,E=3.5MeV). The critical currents at 1T and 10K are enhanced by a factor of 5 for the neutron irradiated and a factor of 9 for the proton irradiated sample respectively. After irradiation the crystals were annealed at 100, 200 and 300C for 8h each in air. Following each annealing step the critical temperature and the magnetization hysteresis at 10 and 70K was measured. Upon annealing, we observe a decrease of the critical currents, which is more pronounced for the proton irradiated sample. This decrease is related to the removal of point defects or their small clusters. Thus, their contribution to pinning can be studied. The critical temperature decreases after both types of irradiation by about 0.5K and is fully recovered after annealing

  19. Developments, characterization and proton irradiation damage tests of AlN detectors for VUV solar observations

    Energy Technology Data Exchange (ETDEWEB)

    BenMoussa, A., E-mail: ali.benmoussa@stce.be [Solar Terrestrial Center of Excellence (STCE), Royal Observatory of Belgium, Circular Avenue 3, B-1180 Brussels (Belgium); Soltani, A.; Gerbedoen, J.-C [Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), F-59652 Villeneuve d’Ascq (France); Saito, T. [Department of Environment and Energy, Tohoku Institute of Technology, 35-1, Yagiyama-Kasumi-cho, Taihaku-ku, Sendai, Miyagi 982-8577 (Japan); Averin, S. [Fryazino Branch of the Kotel’nikov Institute of Radioengineering and Electronics of Russian Academy of Sciences, 141190 Square Vvedenski 1, Fryazino, Moscow Region (Russian Federation); Gissot, S.; Giordanengo, B. [Solar Terrestrial Center of Excellence (STCE), Royal Observatory of Belgium, Circular Avenue 3, B-1180 Brussels (Belgium); Berger, G. [Catholic University of Louvain-la-Neuve, Chemin du Cyclotron 2, B-1348 Louvain la Neuve (Belgium); Kroth, U. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, D-10587 Berlin (Germany); De Jaeger, J.-C. [Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), F-59652 Villeneuve d’Ascq (France); Gottwald, A. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, D-10587 Berlin (Germany)

    2013-10-01

    For next generation spaceborne solar ultraviolet radiometers, innovative metal–semiconductor–metal detectors based on wurtzite aluminum nitride are being developed and characterized. A set of measurement campaigns and proton irradiation damage tests was carried out to obtain their ultraviolet-to-visible characterization and degradation mechanisms. First results on large area prototypes up to 4.3 mm diameter are presented here. In the wavelength range of interest, this detector is reasonably sensitive and stable under brief irradiation with a negligible low dark current (3–6 pA/cm{sup 2}). No significant degradation of the detector performance was observed after exposure to protons of 14.4 MeV energy, showing a good radiation tolerance up to fluences of 1 × 10{sup 11} protons/cm{sup 2}.

  20. Electron spin resonance signal from a tetra-interstitial defect in silicon

    CERN Document Server

    Mchedlidze, T

    2003-01-01

    The Si-B3 electron spin resonance (ESR) signal from agglomerates of self-interstitials was detected for the first time in hydrogen-doped float-zone-grown silicon samples subjected to annealing after electron irradiation. Previously this signal had been detected only in neutron- or proton-irradiated silicon samples. The absence of obscuring ESR peaks for the investigated samples at applied measurement conditions allowed an investigation of the hyperfine structure of the Si-B3 spectra. The analysis supports assignment of a tetra-interstitial defect as the origin of the signal.

  1. Numerical modelling of floating debris in the world's oceans.

    Science.gov (United States)

    Lebreton, L C-M; Greer, S D; Borrero, J C

    2012-03-01

    A global ocean circulation model is coupled to a Lagrangian particle tracking model to simulate 30 years of input, transport and accumulation of floating debris in the world ocean. Using both terrestrial and maritime inputs, the modelling results clearly show the formation of five accumulation zones in the subtropical latitudes of the major ocean basins. The relative size and concentration of each clearly illustrate the dominance of the accumulation zones in the northern hemisphere, while smaller seas surrounded by densely populated areas are also shown to have a high concentration of floating debris. We also determine the relative contribution of different source regions to the total amount of material in a particular accumulation zone. This study provides a framework for describing the transport, distribution and accumulation of floating marine debris and can be continuously updated and adapted to assess scenarios reflecting changes in the production and disposal of plastic worldwide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Effect of front and rear incident proton irradiation on silicon solar cells

    Science.gov (United States)

    Anspaugh, Bruce; Kachare, Ram

    1987-01-01

    Four solar cell types of current manufacture were irradiated through the front and rear surfaces with protons in the energy range between 1 and 10 MeV. The solar cell parameters varied for this study were cell thickness and back surface field (BSF) vs. no BSF. Some cells were irradiated at normal incidence and an equal number were irradiated with simulated isotropic fluences. The solar cell electrical characteristics were measured under simulated AM0 illumination after each fluence. Using the normal incidence data, proton damage coefficients were computed for all four types of cells for both normal and omnidirectional radiation fields. These were found to compare well with the omnidirectional damage coefficients derived directly from the rear-incidence radiation data. Similarly, the rear-incidence omnidirectional radiation data were used to compute appropriate damage coefficients. A method for calculating the effect of a spectrum of energies is derived from these calculations. It is suitable for calculating the degradation of cells in space when they have minimal rear-surface shielding.

  3. Nanoindentation and in situ microcompression in different dose regimes of proton beam irradiated 304 SS

    Energy Technology Data Exchange (ETDEWEB)

    Reichardt, A. [Department of Nuclear Engineering, University of California, Berkeley, CA (United States); Lupinacci, A. [National Center for Electron Microscopy, Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Frazer, D.; Bailey, N.; Vo, H.; Howard, C. [Department of Nuclear Engineering, University of California, Berkeley, CA (United States); Jiao, Z. [Department of Nuclear Engineering, University of Michigan, Ann Arbor, MI (United States); Minor, A.M. [National Center for Electron Microscopy, Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Chou, P. [Electric Power Research Institute, Palo Alto, CA (United States); Hosemann, P., E-mail: peterh@berkeley.edu [Department of Nuclear Engineering, University of California, Berkeley, CA (United States)

    2017-04-01

    Recent developments in micromechanical testing have allowed for the efficient evaluation of radiation effects in micron-scale volumes of ion-irradiated materials. In this study, both nanoindentation and in situ SEM microcompression testing are carried out on 10 dpa proton beam irradiated 304 stainless steel to assess radiation hardening and radiation-induced deformation mechanisms in the material. Using a focused ion beam (FIB), arrays of 2 μm × 2 μm cross-section microcompression pillars are fabricated in multiple dose regimes within the same grain, providing dose-dependent behavior in a single crystal orientation. Analysis of the microcompression load-displacement data and real-time SEM imaging during testing indicates significant hardening, as well as increased localization of deformation in the irradiated material. Although nanoindentation results suggest that irradiation hardening saturates at low doses, microcompression results indicate that the pillar yield stress continues to rise with dose above 10 dpa in the tested orientation. - Highlights: •Mechanical properties are probed in small volumes of proton irradiated 304SS. •Nanoindentation indicates saturation of irradiation hardening at doses of 5–10 dpa. •Microcompression of irradiated specimens suggest localized deformation.

  4. Influence of the interface on the magnetic properties of NiZn ferrite thin films treated by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, X.D. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Guo, D.W. [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Zhang, C.H., E-mail: c.h.zhang@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Fan, X.L.; Chai, G.Z. [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China); Xue, D.S., E-mail: xueds@lzu.edu.cn [Key Laboratory for Magnetism and Magnetic Materials of the Ministry of Education, Lanzhou University, Lanzhou 730000 (China)

    2015-09-01

    In order to systematically investigate the influence of the interface on the magnetic properties, polycrystalline NiZn ferrite thin films were irradiated with 60 keV proton in the dose range from 5 × 10{sup 12} to 5 × 10{sup 16} ions/cm{sup 2}. A non-destructive approach by proton irradiation was found to finely adjust the magnetic properties of polycrystalline NiZn ferrite thin films such as coercivity, perpendicular magnetic anisotropy as well as the effective g value. The coercivity is about 725 Oe for high proton dose ferrite, which is twice larger than the unirradiated one. The ferromagnetic resonance measurements indicated that perpendicular magnetic anisotropy and the effective g value increase with the irradiation dose. Our finding indicates that all modifications of these magnetic properties were associated with the change of interface due to the diffusion and the stress induced by proton irradiation. The change of the effective g value is a result of lattice expansion and the decrease of the magnetic dipole interaction between the columnar grains. This work provides a feasible way to tailor the magnetic properties of thin films by ion irradiation and promotes investigations for the stability of magnetic thin film devices in space or unclear radiation environments.

  5. Permeability coefficient of proton irradiated polyethylene terephatalate thin films

    International Nuclear Information System (INIS)

    Bassani, L.C.; Santos, W.M.S.; Marechal, B.

    1983-01-01

    The principle of operation of an apparatus developed to study gas permation through thin films is described and the measurement method is discussed. Use is made of diffusion theory to obtain a expression for the permeability coefficient as a function of the rate of increase of the pressure in the receiving volume. The Gibbs function for permeation of Helium through Polyethylene Terephtalate (P.E.T.) is determined. The permeability coefficient of Helium is found to increase significantly with the range of the implanted protons although the incident charge has been kept constant. The hypothesis of structural modifications of the proton implanted P.E.T. seems to be confirmed by small angles X-rays scattering experiments on the irradiated samples. (Author) [pt

  6. Properties of iron-doped multicrystalline silicon grown by the float-zone technique

    Energy Technology Data Exchange (ETDEWEB)

    Ciszek, T.F.; Wang, T.H.; Ahrenkiel, R.K.; Matson, R. [National Renewable Energy Lab., Golden, CO (United States)

    1996-05-01

    Multicrystalline Fe-doped Si ingots were float-zoned from high-purity feed rods. Fe was introduced by pill-doping, which gives uniform impurity content for small segregation coefficients (k {approximately} 10{sup {minus}5} for Fe in Si). Fe concentrations were calculated from the initial weight of the Fe pill, the molten zone geomet and the growth parameters. Values in the range of 10{sup 12}-10{sup 16} atoms/cm{sup 3} were targeted. No additional electrically active dopants were introduced. Minority charge carrier lifetime (via YAG-laser-excited, 430-MHz ultra-high-frequency-coupled, photoconductive decay) was measured on the ingots, and wafers were cut to examine grain structure and electron-beam-induced current response of grain boundaries. Observed lifetimes decreased monotonically with increasing Fe content for similar grain sizes (from {approximately}10 {mu}s to 2 {mu}s for < 10{sup {minus}3} cm{sup 2} grains, from {approximately}30 {mu}s to 2 {mu}s for {approximately}5 x 10{sup {minus}3} cm{sup 2} grains, and from {approximately}300 {mu}s to 2 {mu}s for > 10{sup {minus}2} cm{sup 2} grains) as the Fe content increased to 1 {times} 10{sup 16} atoms/cm{sup 3}.

  7. Deep defect levels in standard and oxygen enriched silicon detectors before and after **6**0Co-gamma-irradiation

    CERN Document Server

    Stahl, J; Lindström, G; Pintilie, I

    2003-01-01

    Capacitance Deep Level Transient Spectroscopy (C-DLTS) measurements have been performed on standard and oxygen-doped silicon detectors manufactured from high-resistivity n-type float zone material with left angle bracket 111 right angle bracket and left angle bracket 100 right angle bracket orientation. Three different oxygen concentrations were achieved by the so-called diffusion oxygenated float zone (DOFZ) process initiated by the CERN-RD48 (ROSE) collaboration. Before the irradiation a material characterization has been performed. In contrast to radiation damage by neutrons or high- energy charged hadrons, were the bulk damage is dominated by a mixture of clusters and point defects, the bulk damage caused by **6**0Co-gamma-radiation is only due to the introduction of point defects. The dominant electrically active defects which have been detected after **6**0Co-gamma-irradiation by C-DLTS are the electron traps VO//i, C//iC//s, V//2( = /-), V //2(-/0) and the hole trap C//i O//i. The main difference betwe...

  8. Experimental study on x-rays dose enhancement effects for floating gate ROMs

    CERN Document Server

    Guo Hong Xia; Chen Yu Sheng; Han Fu Bin; He Chao Hui; Zhao Hui

    2002-01-01

    Experimental results of x-ray dose enhancement effects are given for floating gate read-only memory (ROMs) irradiated in the Beijing Synchrotron Radiation Facility. The wrong byte numbers vs. total irradiation dose have been tested and the equivalent relation of total dose damage is provided compared the response of devices irradiated with sup 6 sup 0 Co gamma-ray source. The x-ray dose enhancement factors for floating gate ROMs are obtained firstly in China. These results can be an effective evaluation data for x-rays radiation hardening technology

  9. Single-crystal growth of Group IVB and VB carbides by the floating-zone method

    International Nuclear Information System (INIS)

    Finch, C.B.; Chang, Y.K.; Abraham, M.M.

    1989-02-01

    The floating-zone method for the growth of Group IVB and VB carbides is described and reviewed. We have systematically investigated the technique and confirmed the growth of large single crystals of TiC/sub 0.95/, ZrC/sub 0.93/, ZrC/sub 0.98/, VC/sub 0.80/, NbC/sub 0.95/, TaC/sub 0.89/. Optimal growth conditions were in the 0.5-2.0 cm/h range under 8-12 atm helium. Good crystal growth results were achieved with hot-pressed starting rods of 90-95% density, using a ''double pancake'' induction coil and a 200-kHz/100- kW rf power supply. 36 refs., 5 figs., 3 tabs

  10. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    CERN Document Server

    Gencer, A.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-01-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between View the MathML source10μA and View the MathML source1.2mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam ...

  11. Microarray Cluster Analysis of Irradiated Growth Plate Zones Following Laser Microdissection

    International Nuclear Information System (INIS)

    Damron, Timothy A.; Zhang Mingliang; Pritchard, Meredith R.; Middleton, Frank A.; Horton, Jason A.; Margulies, Bryan M.; Strauss, Judith A.; Farnum, Cornelia E.; Spadaro, Joseph A.

    2009-01-01

    Purpose: Genes and pathways involved in early growth plate chondrocyte recovery after fractionated irradiation were sought as potential targets for selective radiorecovery modulation. Materials and Methods: Three groups of six 5-week male Sprague-Dawley rats underwent fractionated irradiation to the right tibiae over 5 days, totaling 17.5 Gy, and then were killed at 7, 11, and 16 days after the first radiotherapy fraction. The growth plates were collected from the proximal tibiae bilaterally and subsequently underwent laser microdissection to separate reserve, perichondral, proliferative, and hypertrophic zones. Differential gene expression was analyzed between irradiated right and nonirradiated left tibia using RAE230 2.0 GeneChip microarray, compared between zones and time points and subjected to functional pathway cluster analysis with real-time polymerase chain reaction to confirm selected results. Results: Each zone had a number of pathways showing enrichment after the pattern of hypothesized importance to growth plate recovery, yet few met the strictest criteria. The proliferative and hypertrophic zones showed both the greatest number of genes with a 10-fold right/left change at 7 days after initiation of irradiation and enrichment of the most functional pathways involved in bone, cartilage, matrix, or skeletal development. Six genes confirmed by real-time polymerase chain reaction to have early upregulation included insulin-like growth factor 2, procollagen type I alpha 2, matrix metallopeptidase 9, parathyroid hormone receptor 1, fibromodulin, and aggrecan 1. Conclusions: Nine overlapping pathways in the proliferative and hypertrophic zones (skeletal development, ossification, bone remodeling, cartilage development, extracellular matrix structural constituent, proteinaceous extracellular matrix, collagen, extracellular matrix, and extracellular matrix part) may play key roles in early growth plate radiorecovery.

  12. Measurement and investigation of proton irradiation-induced charge transfer inefficiency in PPD CIS at different integration times

    Science.gov (United States)

    Xue, Yuanyuan; Wang, Zujun; Zhang, Fengqi; Bian, Jingying; Yao, Zhibin; He, Baoping; Liu, Minbo; Sheng, Jiangkun; Ma, Wuying; Dong, Guantao; Jin, Junshan

    2018-04-01

    Charge transfer inefficiency (CTI) is an important parameter for photodiode (PPD) CMOS image sensors (CISs). A test system was built and used to measure the CTI of PPD CIS devices at different integration times. The radiation effects of 3 MeV and 10 MeV protons on the CTI were investigated. The experiments were carried out at the EN Tandem Van de Graaff accelerator at proton fluences in the range 1010 to 1011 p/cm2. The CTI was measured within the 2 h following proton radiations. The dependence of CTI on integration time, proton energy and fluence were investigated. The CTI was observed to increase after proton irradiation: with the effect of irradiation with 3 MeV proton being more severe than that with 10 MeV protons. The CTI was also observed to decrease with increasing integration time, which is thought to be related to the charge density in the space charge region (SCR) of the CIS devices. This work has provided a simple method to measure the CTI and helped us to understand proton radiation effects on the CTI of PPD CISs.

  13. Influence of High-Energy Proton Irradiation on β-Ga2O3 Nanobelt Field-Effect Transistors.

    Science.gov (United States)

    Yang, Gwangseok; Jang, Soohwan; Ren, Fan; Pearton, Stephen J; Kim, Jihyun

    2017-11-22

    The robust radiation resistance of wide-band gap materials is advantageous for space applications, where the high-energy particle irradiation deteriorates the performance of electronic devices. We report on the effects of proton irradiation of β-Ga 2 O 3 nanobelts, whose energy band gap is ∼4.85 eV at room temperature. Back-gated field-effect transistor (FET) based on exfoliated quasi-two-dimensional β-Ga 2 O 3 nanobelts were exposed to a 10 MeV proton beam. The proton-dose- and time-dependent characteristics of the radiation-damaged FETs were systematically analyzed. A 73% decrease in the field-effect mobility and a positive shift of the threshold voltage were observed after proton irradiation at a fluence of 2 × 10 15 cm -2 . Greater radiation-induced degradation occurs in the conductive channel of the β-Ga 2 O 3 nanobelt than at the contact between the metal and β-Ga 2 O 3 . The on/off ratio of the exfoliated β-Ga 2 O 3 FETs was maintained even after proton doses up to 2 × 10 15 cm -2 . The radiation-induced damage in the β-Ga 2 O 3 -based FETs was significantly recovered after rapid thermal annealing at 500 °C. The outstanding radiation durability of β-Ga 2 O 3 renders it a promising building block for space applications.

  14. Electrochemical behaviour of gold and stainless steel under proton irradiation and active RedOx couples

    Energy Technology Data Exchange (ETDEWEB)

    Leoni, E. [Commissariat a l' Energie Atomique, DEN/DANS/DPC/SCCME, CEA-Saclay, 91191 Gif sur Yvette (France)], E-mail: elisa.leoni@polytechnique.edu; Corbel, C. [Laboratoire des Solides Irradies, Ecole Polytechnique, 91128 Palaiseau (France)], E-mail: catherine.corbel@polytechnique.fr; Cobut, V. [Laboratoire Atomes et Molecules en Astrophysique, Universite de Cergy-Pontoise, 5 Mail Gay-Lussac, Neuville/Oise, 95031 Cergy-Pontoise Cedex (France); Simon, D. [CNRS-CERI 3a rue de la Ferollerie, 45071 Cedex 2 Orleans (France); Feron, D. [Commissariat a l' Energie Atomique, DEN/DANS/DPC/SCCME, CEA-Saclay, 91191 Gif sur Yvette (France)], E-mail: Damien.FERON@cea.fr; Roy, M.; Raquet, O. [Commissariat a l' Energie Atomique, DEN/DANS/DPC/SCCME, CEA-Saclay, 91191 Gif sur Yvette (France)

    2007-12-01

    Model experiments are reported where proton beams delivered by the cyclotron located at CERI (CNRS-Orleans) are used for irradiating AISI 316L/water and Au/water high purity interfaces with 6 MeV protons. The free exchange potentials at the interfaces are recorded as a function of time at room temperature in situ before, under, and after proton irradiation. The evolutions are compared to those calculated for the Nernst potentials associated with the radiolytic RedOx couples. It is shown how the comparison gives evidence that five radiolytic species - O{sub 2}{center_dot}, H{sub 2}O{sub 2}, HO{sub 2}{sup -}, HO{sub 2}{center_dot} and O{sub 2}{center_dot}{sup -} exchange electrons at the Au interfaces in a range of dose rates that vary over three orders of magnitudes, i.e. 0.0048 < dr(10{sup 7} Gy h{sup -1}) < 4.8. The balance between the electron exchanges at Au interfaces is adjusted by the RedOx reactions associated with the above species. The free exchange potential reaches the same steady value for Au and AISI 316L interfaces irradiated at high doses, {>=}2.5 x 10{sup 7} Gy, (0.020 {+-} 0.025) V versus NHE. Such low values are the first ones to be reported. The HO{sub 2}{center_dot} and O{sub 2}{center_dot}{sup -} radical disproportionations play a key role and control the potential at the interfaces under 6 MeV proton flux. This role is generally mostly overlooked for gamma irradiation.

  15. Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z.; Cardwell, D.; Sasikumar, A.; Arehart, A. R.; Ringel, S. A., E-mail: ringel.5@osu.edu [Department of Electrical and Computer Engineering, The Ohio State University, Columbus, Ohio 43210 (United States); Kyle, E. C. H.; Speck, J. S. [Department of Materials, University of California, Santa Barbara, California 93106-5050 (United States); Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D. [Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee 37235 (United States)

    2016-04-28

    The impact of proton irradiation on the threshold voltage (V{sub T}) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of V{sub T} was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 10{sup 14} cm{sup −2}. Silvaco Atlas simulations of V{sub T} shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different V{sub T} dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed V{sub T} shifts. The proton irradiation induced V{sub T} shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.

  16. Correlation of proton irradiation induced threshold voltage shifts to deep level traps in AlGaN/GaN heterostructures

    International Nuclear Information System (INIS)

    Zhang, Z.; Cardwell, D.; Sasikumar, A.; Arehart, A. R.; Ringel, S. A.; Kyle, E. C. H.; Speck, J. S.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.

    2016-01-01

    The impact of proton irradiation on the threshold voltage (V T ) of AlGaN/GaN heterostructures is systematically investigated to enhance the understanding of a primary component of the degradation of irradiated high electron mobility transistors. The value of V T was found to increase monotonically as a function of 1.8 MeV proton fluence in a sub-linear manner reaching 0.63 V at a fluence of 1 × 10 14  cm −2 . Silvaco Atlas simulations of V T shifts caused by GaN buffer traps using experimentally measured introduction rates, and energy levels closely match the experimental results. Different buffer designs lead to different V T dependences on proton irradiation, confirming that deep, acceptor-like defects in the GaN buffer are primarily responsible for the observed V T shifts. The proton irradiation induced V T shifts are found to depend on the barrier thickness in a linear fashion; thus, scaling the barrier thickness could be an effective way to reduce such degradation.

  17. Investigation of the effects of high-energy proton-beam irradiation on metal-oxide surfaces by using methane adsorption isotherms

    International Nuclear Information System (INIS)

    Kim, Euikwoun; Lee, Junggil; Kim, Jaeyong; Kim, Kyeryung

    2012-01-01

    The creation of possible local defects on metal-oxide surfaces due to irradiation with a high-energy proton beam was investigated by using a series of gas adsorption isotherms for methane (CH 4 ) on a MgO powder surface. After a MgO powder surface having only a (100) surface had been irradiated with a 35-MeV proton beam, the second atomic layer of methane had completely disappeared while two distinct atomic layers were found in a layer-by-layer fashion on the surfaces of unirradiated samples. This subtle modification of the surface is evidenced by a change of the contrasts in the morphologies measured a using a transmission electron microscopy. Combined results obtained from an electron microscopy and methane adsorption isotherms strongly suggest that the high-energy proton-beam irradiation induced a local surface modification by imparting kinetic energy to the sample. The calculation of the 2-dimensional compressibility values, which are responsible for the formation of the atomic layers, confirmed the surface modification after irradiating surface-clean MgO powders with a proton beam.

  18. A study of proton polarization in ammonia (NH sub 3 ) under irradiation and annealing

    Energy Technology Data Exchange (ETDEWEB)

    Belyaev, A.A.; Get' man, V.A.; Dzyubak, A.P.; Karnaukhov, I.M.; Lukhanin, A.A.; Neffa, A.Yu.; Semisalov, I.L.; Sorokin, P.V.; Sporov, E.S.; Telegin, Yu.N.; Tolmachev, I.A.; Trotsenko, V.I. (Kharkov Institute of Physics and Technology, Ukrainian SSR, Academy of Sciences, 310108 Kharkov, USSR (UA))

    1989-05-05

    The proton polarization in irradiated NH{sub 3} has been measured as a function of the irradiation dose and annealing temperature. The analysis of the experimental data obtained shows that under low-temperature'' irradiation along with the NH{sup {minus}}{sub 2} the e{sub tr}-radical is likely to be formed which contributes to the polarization build-up and relaxation and influences the radiation damage resistance of the target.

  19. Dosimetric comparison of proton and photon three-dimensional, conformal, external beam accelerated partial breast irradiation techniques

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Katz, Angela; Adams, Judith C.; Crowley, Elizabeth M.; Nyamwanda, Jacqueline A.C.; Feng, Jennifer K.C.; Doppke, Karen P.; DeLaney, Thomas F.; Taghian, Alphonse G.

    2006-01-01

    Purpose: To compare the dosimetry of proton and photon-electron three-dimensional, conformal, external beam accelerated partial breast irradiation (3D-CPBI). Methods and Materials: Twenty-four patients with fully excised, Stage I breast cancer treated with adjuvant proton 3D-CPBI had treatment plans generated using the mixed-modality, photon-electron 3D-CPBI technique. To facilitate dosimetric comparisons, planning target volumes (PTVs; lumpectomy site plus 1.5-2.0 cm margin) and prescribed dose (32 Gy) were held constant. Plans were optimized for PTV coverage and normal tissue sparing. Results: Proton and mixed-modality plans both provided acceptable PTV coverage with 95% of the PTV receiving 90% of the prescribed dose in all cases. Both techniques also provided excellent dose homogeneity with a dose maximum exceeding 110% of the prescribed dose in only one case. Proton 3D-CPBI reduced the volume of nontarget breast tissue receiving 50% of the prescribed dose by an average of 36%. Statistically significant reductions in the volume of total ipsilateral breast receiving 100%, 75%, 50%, and 25% of the prescribed dose were also observed. The use of protons resulted in small, but statistically significant, reductions in the radiation dose delivered to 5%, 10%, and 20% of ipsilateral and contralateral lung and heart. The nontarget breast tissue dosimetric advantages of proton 3D-CPBI were not dependent on tumor location, breast size, PTV size, or the ratio of PTV to breast volume. Conclusions: Compared to photon-electron 3D-CPBI, proton 3D-CPBI significantly reduces the volume of irradiated nontarget breast tissue. Both approaches to accelerated partial breast irradiation offer exceptional lung and heart sparing

  20. The gas bubbles distribution in 600 MeV protons irradiated aluminium

    International Nuclear Information System (INIS)

    Gavillet, D.; Martin, J.L.; Victoria, M.; Green, W.

    1984-01-01

    In order to simulate the damage produced by 14 MeV fusion neutrons, thin foils of high purity Al have been irradiated by a proton beam of 580 MeV (120μA). After irradiation at temperatures higher than 0.5 Tm transmission electron microscope observations of gas bubbles distribution were performed. At 200 0 C a uniform distribution of bubbles has been observed inside the grain. The average distance between bubbles and their density have been determined. The gas pressure inside the bubbles has been estimated [fr

  1. Study of crosslinking onset and hydrogen annealing of ultra-high molecular weight polyethylene irradiated with high-energy protons

    Science.gov (United States)

    Wilson, John Ford

    1997-09-01

    Ultra high molecular weight polyethylene (UHMW-PE) is used extensively in hip and knee endoprostheses. Radiation damage from the sterilization of these endoprostheses prior to surgical insertion results in polymer crosslinking and decreased oxidative stability. The motivation for this study was to determine if UHMW-PE could be crosslinked by low dose proton irradiation with minimal radiation damage and its subsequent deleterious effects. I found that low dose proton irradiation and post irradiation hydrogen annealing did crosslink UHMW-PE and limit post irradiation oxidation. Crosslinking onset was investigated for UHMW-PE irradiated with 2.6 and 30 MeV H+ ions at low doses from 5.7 × 1011-2.3 × 1014 ions/cm2. Crosslinking was determined from gel permeation chromatography (GPC) of 1,2,4 trichlorobenzene sol fractions and increased with dose. Fourier transform infrared spectroscopy (FTIR) showed irradiation resulted in increased free radicals confirmed from increased carbonyl groups. Radiation damage, especially at the highest doses observed, also showed up in carbon double bonds and increased methyl end groups. Hydrogen annealing after ion irradiation resulted in 40- 50% decrease in FTIR absorption associated with carbonyl. The hydrogen annealing prevented further oxidation after aging for 1024 hours at 80oC. Hydrogen annealing was successful in healing radiation damage through reacting with the free radicals generated during proton irradiation. Polyethylenes, polyesters, and polyamides are used in diverse applications by the medical profession in the treatment of orthopedic impairments and cardiovascular disease and for neural implants. These artificial implants are sterilized with gamma irradiation prior to surgery and the resulting radiation damage can lead to accelerated deterioration of the implant properties. The findings in this study will greatly impact the continued use of these materials through the elimination of many problems associated with radiation

  2. Results of treatment of Icenko-Cushing disease with proton beam irradiation of the pituitary gland

    International Nuclear Information System (INIS)

    Marova, E.I.; Starkova, N.T.; Kirpatovskaya, L.E.; Kolesnikova, G.S.; Bukhman, A.I.; Rozhinskaya, L.Ya.; Bel'chenko, L.V.

    1987-01-01

    Proton beam therapy was given to 98 patients with Icenko-Cushing disease aged 15 to 40. Mild cases were treated by proton beam irradiation only while severe cases were managed using proton beam therapy combined with unilateral adrenalectomy or ortho-para-DDD. Catamnesis duration varied from 3 to 5 years. In most cases the exposure dose was 80-90 Gy (50-110 Gy). The procedure was well tolerated by all the patients. A dynamic multipolar converting method with 15-20 entrance poles in the left temporal area was employed (with the beam energy of 200 MeV). Stabilization of the course of disease and some clinical improvement were observed in most of the patients 3-4 months after proton beam therapy. In 6-36 months after irradiation 90% of the patients showed normal biochemical indices and the absence of any clinical signs of the disease. Thus the results of proton beam therapy of 98 patients with Icenko-Cushing disease after a follow-up of 3-5 years showed a high efficacy of this type of treatment. The method can be used alone or in combination with unilateral adrenalectomy as well as with oral administration of ortho-para-DDD

  3. Analysis of Global Solar Irradiance over Climatic Zones in Nigeria for Solar Energy Applications

    Directory of Open Access Journals (Sweden)

    Adekunle Ayodotun Osinowo

    2015-01-01

    Full Text Available Satellite derived solar irradiance over 25 locations in the 5 climatic zones of Nigeria (tropical rainforest TRF, Guinea savannah GS, Sahel savannah SHS, Sudan savannah SUS, and Mangrove swamp forest MSF was analyzed. To justify its use, the satellite data was tested for goodness of agreement with ground measured solar radiation data using 26-year mean monthly and daily data over 16 locations in the 5 climatic zones. The well-known R2, RMSE, MBE, and MPE statistical tests were used and good agreement was found. The 25 locations were grouped into the 5 climatic zones. Frequency distribution of global solar irradiance was done for each of the climatic zones. This showed that 46.88%, and 40.6% of the number of days (9794 over TRF and MSF, respectively, had irradiation within the range of 15.01–20.01 MJ/m2/day. For the GS, SHS, and SUS, 46.19%, 55.84% and 58.53% of the days had total irradiation within the range of 20.01–25.01 MJ/m2/day, respectively. Generally, in all the climatic zones, coefficients of variation of solar radiation were high and mean values were low in July and August. Contour maps showed that high and low values of global solar irradiance and clearness index were observed in the Northern and Southern locations of Nigeria, respectively.

  4. The effects of oxide evolution on mechanical properties in proton- and neutron-irradiated Fe-9%Cr ODS steel

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, M.J., E-mail: matthewswenson1@u.boisestate.edu [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Dolph, C.K. [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Wharry, J.P. [Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Purdue University, 400 Central Drive, West Lafayette, IN 47907 (United States)

    2016-10-15

    The objective of this study is to evaluate the effect of irradiation on the strengthening mechanisms of a model Fe-9%Cr oxide dispersion strengthened steel. The alloy was irradiated with protons or neutrons to a dose of 3 displacements per atoms at 500 °C. Nanoindentation was used to measure strengthening due to irradiation, with neutron irradiation causing a greater increase in yield strength than proton irradiation. The irradiated microstructures were characterized using transmission electron microscopy and atom probe tomography (APT). Cluster analysis reveals solute migration from the Y-Ti-O-rich nanoclusters to the surrounding matrix after both irradiations, though the effect is more pronounced in the neutron-irradiated specimen. Because the dissolved oxygen atoms occupy interstitial sites in the iron matrix, they contribute significantly to solid solution strengthening. The dispersed barrier hardening model relates microstructure evolution to the change in yield strength, but is only accurate if solid solution contributions to strengthening are considered simultaneously.

  5. Multi-MW accelerator target material properties under proton irradiation at Brookhaven National Laboratory linear isotope producer

    Science.gov (United States)

    Simos, N.; Ludewig, H.; Kirk, H.; Dooryhee, E.; Ghose, S.; Zhong, Z.; Zhong, H.; Makimura, S.; Yoshimura, K.; Bennett, J. R. J.; Kotsinas, G.; Kotsina, Z.; McDonald, K. T.

    2018-05-01

    The effects of proton beams irradiating materials considered for targets in high-power accelerator experiments have been studied using the Brookhaven National Laboratory's (BNL) 200 MeV proton linac. A wide array of materials and alloys covering a wide range of the atomic number (Z) are being scoped by the high-power accelerator community prompting the BNL studies to focus on materials representing each distinct range, i.e. low-Z, mid-Z and high-Z. The low range includes materials such as beryllium and graphite, the midrange alloys such as Ti-6Al-4V, gum metal and super-Invar and finally the high-Z range pure tungsten and tantalum. Of interest in assessing proton irradiation effects are (a) changes in physiomechanical properties which are important in maintaining high-power target functionality, (b) identification of possible limits of proton flux or fluence above which certain materials cease to maintain integrity, (c) the role of material operating temperature in inducing or maintaining radiation damage reversal, and (d) phase stability and microstructural changes. The paper presents excerpt results deduced from macroscopic and microscopic post-irradiation evaluation (PIE) following several irradiation campaigns conducted at the BNL 200 MeV linac and specifically at the isotope producer beam-line/target station. The microscopic PIE relied on high energy x-ray diffraction at the BNL NSLS X17B1 and NSLS II XPD beam lines. The studies reveal the dramatic effects of irradiation on phase stability in several of the materials, changes in physical properties and ductility loss as well as thermally induced radiation damage reversal in graphite and alloys such as super-Invar.

  6. Positronium formation in helium bubbles in 600 MeV proton-irradiated aluminium

    DEFF Research Database (Denmark)

    Jensen, K. O.; Eldrup, Morten Mostgaard; Singh, Bachu Narain

    1985-01-01

    Aluminium samples containing helium bubbles produced by 600 MeV proton irradiation at 430°C were investigated by positron annihilation; both lifetime and angular correlation measurements were made. The angular correlation curves contain an unusually narrow component. This component is associated...

  7. Effect of impurities on the growth of {113} interstitial clusters in silicon under electron irradiation

    OpenAIRE

    Nakai, K.; Hamada, K.; Satoh, Y.; Yoshiie, T.

    2011-01-01

    The growth and shrinkage of interstitial clusters on {113} planes were investigated in electron irradiated Czochralski grown silicon (Cz-Si), floating-zone silicon (Fz-Si), and impurity-doped Fz-Si (HT-Fz-Si) using a high voltage electron microscope. In Fz-Si, {113} interstitial clusters were formed only near the beam incident surface after a long incubation period, and shrank on subsequent irradiation from the backside of the specimen. In Cz-Si and HT-Fz-Si, {113} interstitial clusters nucle...

  8. Study of Microhardness and Electrical Properties of Proton Irradiated Polyether sulfone

    International Nuclear Information System (INIS)

    Quresh, A.

    2006-01-01

    Polyethersulfone (PES) films were irradiated with 3 MeV proton beams in the fluence range 10 1 3-10 1 5 ions/cm 2 . The irradiated samples were characterized by a Vickers' microhardness tester at a load of 100-1000 mN, and electrical properties in the frequency range 100 Hz to 1MHz by an LCR meter. It is observed that microhardness increases as fluence increases up to the fluence of 10 1 4 ions/cm 2 and decreases on further increase of the fluence. This may be attributed to the fact that a cross linking phenomenon dominates up to the fluence of 10 1 4 ions/cm 2 . There is an exponential increase in conductivity and the effect of irradiation is significant at higher fluences. The dielectric constant/loss was found to change significantly due to irradiation. It has been found that dielectric response in both pristine and irradiated samples obey universal law is given by ε α f n -1.These results were corroborated with structural changes observed in FTIR spectra of pristine and irradiated samples

  9. Long-lived isotopes production in Pb-Bi target irradiated by high energy protons

    Energy Technology Data Exchange (ETDEWEB)

    Korovin, Y.A.; Konobeyev, A.Y.; Pereslavtsev, P.E. [Obninsk Institute of Nuclear Power Engineering, Obninsk (Russian Federation)

    1995-10-01

    Concentration of long-lived isotopes has been calculated for lead and lead-bismuth targets irradiated by protons with energy 0.4, 0.8, 1.0 and 1.6 GeV. The time of irradiation is equal from 1 month up to 2 years. The data libraries BROND, ADL and MENDL have been used to obtain the rate of nuclide transmutation. All calculations have been performed using the SNT code.

  10. Defect microstructure in copper alloys irradiated with 750 MeV protons

    DEFF Research Database (Denmark)

    Zinkle, S.J.; Horsewell, A.; Singh, B.N.

    1994-01-01

    Transmission electron microscopy (TEM) disks of pure copper and solid solution copper alloys containing 5 at% of Al, Mn, or Ni were irradiated with 750 MeV protons to damage levels between 0.4 and 2 displacements per atom (dpa) at irradiation temperatures between 60 and 200 degrees C. The defect...... significant effect on the total density of small defect clusters, but they did cause a significant decrease in the fraction of defect clusters resolvable as SFT to similar to 20 to 25%. In addition, the dislocation loop density (> 5 nm diameter) was more than an order of magnitude higher in the alloys...

  11. Tensile properties in zircaloy-II after 590 MeV proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Y. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Victoria, M. [Ecole Polytechnique Federale, Lausanne (Switzerland)

    1997-09-01

    In order to investigate radiation potential damage effects on the SINQ Zircaloy-rod target, four Zircaloy-II tensile specimens were irradiated at the PIREX facility in 1995 to a proton fluence about 3x10{sup 20} p/cm{sup 2}, which produced a radiation damage of about 1.35 displacements per atom (dpa). Tensile test results show that, although there is some reduction in tensile elongation, substantial ductility still exists after such irradiation dose which corresponds to the peak value obtained in the SINQ target for 23 days operation at 1 mA. (author) 1 fig., 2 refs.

  12. Proton Irradiation Impacts Age Driven Modulations of Cancer Progression Influenced by Immune System Transcriptome Modifications from Splenic Tissue

    Data.gov (United States)

    National Aeronautics and Space Administration — Age plays a crucial role in the interplay between tumor and host; with further perturbations induced by irradiation. Proton irradiation on tumors induces biological...

  13. Characterization of the proton irradiation induced luminescence of materials and application in radiation oncology dosimetry

    Science.gov (United States)

    Darafsheh, Arash; Zhang, Rongxiao; Kassaee, Alireza; Finlay, Jarod C.

    2018-03-01

    Visible light generated as the result of interaction of ionizing radiation with matter can be used for radiation therapy quality assurance. In this work, we characterized the visible light observed during proton irradiation of poly(methyl methacrylate) (PMMA) and silica glass fiber materials by performing luminescence spectroscopy. The spectra of the luminescence signal from PMMA and silica glass fibers during proton irradiation showed continuous spectra whose shape were different from that expected from Čerenkov radiation, indicating that Čerenkov radiation cannot be the responsible radioluminescence signal. The luminescence signal from each material showed a Bragg peak pattern and their corresponding proton ranges are in agreement with measurements performed by a standard ion chamber. The spectrum of the silica showed two peaks at 460 and 650 nm stem from the point defects of the silica: oxygen deficiency centers (ODC) and non-bridging oxygen hole centers (NBOHC), respectively. The spectrum of the PMMA fiber showed a continuous spectrum with a peak at 410 nm whose origin is connected with the fluorescence of the PMMA material. Our results are of interest for various applications based on imaging radioluminescent signal in proton therapy and will inform on the design of high-resolution fiber probes for proton therapy dosimetry.

  14. Defect recovery in proton irradiated Ti-modified stainless steel probed by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Arunkumar, J.; Abhaya, S.; Rajaraman, R.; Amarendra, G. [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India); Nair, K.G.M. [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India)], E-mail: kgmn@igcar.gov.in; Sundar, C.S.; Raj, Baldev [Materials Science Division, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu 603102 (India)

    2009-02-28

    The defect recovery in proton irradiated Ti-modified D9 steel has been studied by positron annihilation isochronal and isothermal annealing measurements. D9 samples have been irradiated with 3 MeV protons followed by isochronal annealing at various temperatures in the range of 323 to 1273 K. The dramatic decrease in positron annihilation parameters, viz. positron lifetime and Doppler S-parameter, around 500 K indicates the recovery of vacancy-defects. A clear difference in the recovery beyond 700 K is observed between solution annealed and cold worked state of D9 steel due to the precipitation of TiC in the latter. Isothermal annealing studies have been carried out at the temperature wherein vacancies distinctly migrate. Assuming a singly activated process for defect annealing, the effective activation energy for vacancy migration is estimated to be 1.13 {+-} 0.08 eV.

  15. Structure modification and medical application of the natural products by proton beam irradiation

    International Nuclear Information System (INIS)

    Lee, D. W.; Park, J. K.; Kang, J. E.; Shin, S. C.; Ahn, J. H.; Lee, E. S.

    2008-04-01

    This study was performed for the investigation of changes of constituent contents of Korean ginseng (Panax genseng C.A. Meyer) after proton beam irradiation (Beam energy from MC-50 cyclotron : 36.5MeV) with beam range of 500 - 10000Gy

  16. Structure modification and medical application of the natural products by proton beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. W.; Park, J. K.; Kang, J. E.; Shin, S. C.; Ahn, J. H.; Lee, E. S. [Dongguk University, Gyeongju (Korea, Republic of)

    2008-04-15

    This study was performed for the investigation of changes of constituent contents of Korean ginseng (Panax genseng C.A. Meyer) after proton beam irradiation (Beam energy from MC-50 cyclotron : 36.5MeV) with beam range of 500 - 10000Gy

  17. Physiologic and Radiographic Evidence of the Distal Edge of the Proton Beam in Craniospinal Irradiation

    International Nuclear Information System (INIS)

    Krejcarek, Stephanie C.; Grant, P. Ellen; Henson, John W.; Tarbell, Nancy J.; Yock, Torunn I.

    2007-01-01

    Purpose: Fatty replacement of bone marrow resulting from radiation therapy can be seen on T1-weighted magnetic resonance (MR) images. We evaluated the radiographic appearance of the vertebral bodies in children treated with proton craniospinal irradiation (CSI) to illustrate the distal edge effect of proton radiotherapy. Methods and Materials: The study cohort consisted of 13 adolescents aged 12-18 years who received CSI with proton radiotherapy at Massachusetts General Hospital. Ten of these patients had reached maximal or near-maximal growth. Proton beam radiation for these 10 patients was delivered to the thecal sac and exiting nerve roots only, whereas the remaining 3 patients had a target volume that included the thecal sac, exiting nerve roots, and entire vertebral bodies. Median CSI dose was 27 [range, 23.4-36] cobalt gray equivalent (CGE) given in 1.8-CGE fractions. Magnetic resonance images of the spine were obtained after completion of radiotherapy. Results: Magnetic resonance images of patients who received proton radiotherapy to the thecal sac only demonstrate a sharp demarcation of hyperintense T1-weighted signal in the posterior aspects of the vertebral bodies, consistent with radiation-associated fatty marrow replacement. Magnetic resonance images of the patients prescribed proton radiotherapy to the entire vertebral column had corresponding hyperintense T1-weighted signal involving the entire vertebral bodies. Conclusion: The sharp delineation of radiation-associated fatty marrow replacement in the vertebral bodies demonstrates the rapid decrease in energy at the edge of the proton beam. This provides evidence for a sharp fall-off in radiation dose and supports the premise that proton radiotherapy spares normal tissues unnecessary irradiation

  18. Proton or photon irradiation for hemangiomas of the choroid? A retrospective comparison

    International Nuclear Information System (INIS)

    Hoecht, Stefan; Wachtlin, Joachim; Bechrakis, Nikolaos E.; Schaefer, Christiane; Heufelder, Jens; Cordini, Dino; Kluge, Heinz; Foerster, Michael; Hinkelbein, Wolfgang

    2006-01-01

    Purpose: The aim of this study was to compare, on a retrospective basis, the results of therapy in patients with uveal hemangioma treated with photon or proton irradiation at a single center. Methods and Materials: From 1993 to 2002 a total of 44 patients were treated. Until 1998 radiotherapy was given with 6 MV photons in standard fractionation of 2.0 Gy 5 times per week. In 1998 proton therapy became available and was used since then. A dose of 20 to 22.5 Cobalt Gray Equivalent (CGE) 68 MeV protons was given on 4 consecutive days. Progressive symptoms or deterioration of vision were the indications for therapy. Results: Of the 44 patients treated, 36 had circumscribed choroidal hemangiomas and 8 had diffuse choroidal hemangiomas (DCH) and Sturge-Weber syndrome. Of the patients, 19 were treated with photons with a total dose in the range of 16 to 30 Gy. A total of 25 patients were irradiated with protons. All patients with DCH but 1 were treated with photons. Stabilization of visual acuity was achieved in 93.2% of all patients. Tumor thickness decreased in 95.4% and retinal detachment resolved in 92.9%. Late effects, although generally mild or moderate, were frequently detected. In all, 40.9% showed radiation-induced optic neuropathy, maximum Grade I. Retinopathy was found in 29.5% of cases, but only 1 patient experienced more than Grade II severity. Retinopathy and radiation-induced optic neuropathy were reversible in some of the patients and in some resolved completely. No differences could be detected between patients with circumscribed choroidal hemangiomas treated with protons and photons. Treatment was less effective in DCH patients (75%). Conclusions: Radiotherapy is effective in treating choroidal hemangiomas with respect to visual acuity and tumor thickness but a benefit of proton therapy could not be detected. Side effects are moderate but careful monitoring for side effects should be part of the follow-up procedures

  19. Characterization of ion irradiation effects on the microstructure, hardness, deformation and crack initiation behavior of austenitic stainless steel:Heavy ions vs protons

    Science.gov (United States)

    Gupta, J.; Hure, J.; Tanguy, B.; Laffont, L.; Lafont, M.-C.; Andrieu, E.

    2018-04-01

    Irradiation Assisted Stress Corrosion Cracking (IASCC) is a complex phenomenon of degradation which can have a significant influence on maintenance time and cost of core internals of a Pressurized Water Reactor (PWR). Hence, it is an issue of concern, especially in the context of lifetime extension of PWRs. Proton irradiation is generally used as a representative alternative of neutron irradiation to improve the current understanding of the mechanisms involved in IASCC. This study assesses the possibility of using heavy ions irradiation to evaluate IASCC mechanisms by comparing the irradiation induced modifications (in microstructure and mechanical properties) and cracking susceptibility of SA 304 L after both type of irradiations: Fe irradiation at 450 °C and proton irradiation at 350 °C. Irradiation-induced defects are characterized and quantified along with nano-hardness measurements, showing a correlation between irradiation hardening and density of Frank loops that is well captured by Orowan's formula. Both irradiations (iron and proton) increase the susceptibility of SA 304 L to intergranular cracking on subjection to Constant Extension Rate Tensile tests (CERT) in simulated nominal PWR primary water environment at 340 °C. For these conditions, cracking susceptibility is found to be quantitatively similar for both irradiations, despite significant differences in hardening and degree of localization.

  20. Effects of high-energy proton irradiation on the superconducting properties of Fe(Se,Te) thin films

    Science.gov (United States)

    Sylva, G.; Bellingeri, E.; Ferdeghini, C.; Martinelli, A.; Pallecchi, I.; Pellegrino, L.; Putti, M.; Ghigo, G.; Gozzelino, L.; Torsello, D.; Grimaldi, G.; Leo, A.; Nigro, A.; Braccini, V.

    2018-05-01

    In this paper we explore the effects of 3.5 MeV proton irradiation on Fe(Se,Te) thin films grown on CaF2. In particular, we carry out an experimental investigation with different irradiation fluences up to 7.30 · 1016 cm‑2 and different proton implantation depths, in order to clarify whether and to what extent the critical current is enhanced or suppressed, what are the effects of irradiation on the critical temperature, resistivity, and critical magnetic fields, and finally what is the role played by the substrate in this context. We find that the effect of irradiation on superconducting properties is generally small compared to the case of other iron-based superconductors. The irradiation effect is more evident on the critical current density Jc, while it is minor on the transition temperature Tc, normal state resistivity ρ, and on the upper critical field Hc2 up to the highest fluences explored in this work. In more detail, our analysis shows that when protons implant in the substrate far from the superconducting film, the critical current can be enhanced up to 50% of the pristine value at 7 T and 12 K; meanwhile, there is no appreciable effect on critical temperature and critical fields together with a slight decrease in resistivity. On the contrary, when the implantation layer is closer to the film–substrate interface, both critical current and temperature show a decrease accompanied by an enhancement of the resistivity and lattice strain. This result evidences that possible modifications induced by irradiation in the substrate may affect the superconducting properties of the film via lattice strain. The robustness of the Fe(Se,Te) system to irradiation-induced damage makes it a promising compound for the fabrication of magnets in high-energy accelerators.

  1. Optical properties of Ni-doped MgGa2O4 single crystals grown by floating zone method

    International Nuclear Information System (INIS)

    Suzuki, Takenobu; Hughes, Mark; Ohishi, Yasutake

    2010-01-01

    The single crystal growth conditions and spectroscopic characterization of Ni-doped MgGa 2 O 4 with inverse-spinel structure crystal family are described. Single crystals of this material have been grown by floating zone method. Ni-doped MgGa 2 O 4 single crystals have broadband fluorescence in the 1100-1600 nm wavelength range, 1.6 ms room temperature lifetime, 56% quantum efficiency and 1.05x10 -21 cm 2 stimulated emission cross section at the emission peak. This new material is very promising for tunable laser applications covering the important optical communication and eye safe wavelength region.

  2. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Jeynes, J.C.G.; Merchant, M.J.; Kirkby, K.; Kirkby, N. [Surrey Ion Beam Center, Faculty of Engineering and Physical Science, University of Surrey, Guildford Surrey, GU2 7XH (United Kingdom); Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: •Recently completed nanobeam at the Surrey Ion Beam Centre was used. •3.8-MeV single and broad proton beams irradiated Chinese hamster cells. •Cell survival curves were measured and compared with 300-kV X-ray irradiation. •Single ion irradiation had a lower survival part at ultra-low dose. •It implies hypersensitivity, bystander effect and cell cycle phase of cell death. -- Abstract: As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  3. Corrosion of target and structural materials in water irradiated by an 800 MeV proton beam

    International Nuclear Information System (INIS)

    Butt, D.P.; Kanner, G.S.; Lillard, R.S.

    1996-01-01

    Radiation enhanced, aqueous corrosion of solid neutron-targets such as tungsten or tantalum, or target cladding or structural materials such as superalloys and stainless steels, is a significant concern in accelerator-driven transmutation technologies. In this paper we briefly describe our current methods for control and in situ monitoring of corrosion in accelerator cooling water loops. Using floating, electrochemical impedance spectroscopy (EIS), we have measured the corrosion rates of aluminum 6061, copper, Inconel 718, and 304L stainless steel in the flow loop of a water target irradiated by a μamp, 800 MeV proton beam. Impedance spectroscopy allows us to model the corrosion process of a material as an equivalent electrical circuit. Thus the polarization resistance, which is inversely proportional to the corrosion rate, can be extracted from the frequency response of a metal specimen. During a three month period, without the use of corrosion mitigation techniques, we observed increases of several orders of magnitude in the water conductivity and the corrosion rates. The increase in corrosion is at least partially attributed to a build up of peroxide in our pseudo-closed loop system. In this paper we also briefly describe our second generation experiments, scheduled to begin in late 1996. In these experiments we plan to measure the corrosion rates of tungsten, tantalum, Inconel 718, 316L and 304L stainless steel, HT-9 austenitic stainless steel, and aluminum 5053. Two or three electrode probes of each material are being placed directly in the proton beam, in a high neutron flux region, or a significant distance from the high radiation area. We will be measuring corrosion rates, changes in pH and conductivity, and we will be establishing parameters for filtration and mitigation of corrosion. We will also discuss our ideas for making in situ measurements of water radiolysis using optical and laser diagnostic techniques

  4. Performance of irradiated silicon microstrip detectors

    International Nuclear Information System (INIS)

    Catacchini, E.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, M.; Meschini, M.; Parrini, G.; Pieri, M.

    1999-01-01

    Silicon microstrip devices to be installed in Large Hadron Collider (LHC) tracking detectors will have to operate in a high radiation environment. We report on performance studies of silicon microstrip detectors irradiated with neutrons or protons, up to fluences comparable to the first ten years of running at LHC. Obtained results show that irradiated detectors can still be operated with satisfactory signal-to-noise ratio,and in the case of inhomogeneously type inverted detector a very good position resolution is achieved regardless of the zone crossed by the particle

  5. Accelerated partial-breast irradiation using proton beams: Initial clinical experience

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Smith, Barbara L.; Adams, Judith C.; Kornmehl, Ellen; Katz, Angela; Gadd, Michele; Specht, Michelle; Hughes, Kevin; Gioioso, Valeria; Lu, H.-M.; Braaten, Kristina; Recht, Abram; Powell, Simon N.; DeLaney, Thomas F.; Taghian, Alphonse G.

    2006-01-01

    Purpose: We present our initial clinical experience with proton, three-dimensional, conformal, external beam, partial-breast irradiation (3D-CPBI). Methods and Materials: Twenty patients with Stage I breast cancer were treated with proton 3D-CPBI in a Phase I/II clinical trial. Patients were followed at 3 to 4 weeks, 6 to 8 weeks, 6 months, and every 6 months thereafter for recurrent disease, cosmetic outcome, toxicity, and patient satisfaction. Results: With a median follow-up of 12 months (range, 8-22 months), no recurrent disease has been detected. Global breast cosmesis was judged by physicians to be good or excellent in 89% and 100% of cases at 6 months and 12 months, respectively. Patients rated global breast cosmesis as good or excellent in 100% of cases at both 6 and 12 months. Proton 3D-CPBI produced significant acute skin toxicity with moderate to severe skin color changes in 79% of patients at 3 to 4 weeks and moderate to severe moist desquamation in 22% of patients at 6 to 8 weeks. Telangiectasia was noted in 3 patients. Three patients reported rib tenderness in the treated area, and one rib fracture was documented. At last follow-up, 95% of patients reported total satisfaction with proton 3D-CPBI. Conclusions: Based on our study results, proton 3D-CPBI offers good-to-excellent cosmetic outcomes in 89% to 100% of patients at 6-month and 12-month follow-up and nearly universal patient satisfaction. However, proton 3D-CPBI, as used in this study, does result in significant acute skin toxicity and may potentially be associated with late skin (telangiectasia) and rib toxicity. Because of the dosimetric advantages of proton 3D-CPBI, technique modifications are being explored to improve acute skin tolerance

  6. Laser polarization dependence of proton emission from a thin foil target irradiated by a 70 fs, intense laser pulse

    International Nuclear Information System (INIS)

    Fukumi, A.; Nishiuchi, M.; Daido, H.; Li, Z.; Sagisaka, A.; Ogura, K.; Orimo, S.; Kado, M.; Hayashi, Y.; Mori, M.; Bulanov, S.V.; Esirkepov, T.; Nemoto, K.; Oishi, Y.; Nayuki, T.; Fujii, T.; Noda, A.; Nakamura, S.

    2005-01-01

    A study of proton emission from a 3-μm-thick Ta foil target irradiated by p-, s-, and circularly polarized laser pulses with respect to the target plane has been carried out. Protons with energies up to 880 keV were observed in the target normal direction under the irradiation by the p-polarized laser pulse, which yielded the highest efficiency for proton emission. In contrast, s- and circularly polarized laser pulses gave the maximum energies of 610 and 680 keV, respectively. The difference in the maximum energy between the p- and s-polarized cases was associated with the difference between the sheath fields estimated from electron spectra

  7. Application of the nuclear microprobe to the study of organic and inorganic composition of teeth irradiated by a laser beam

    International Nuclear Information System (INIS)

    Sommer, F.; Engelmann, Ch.; Couble, Ml.; Magloire, H.; Bonnin, P.

    1986-01-01

    The nuclear microprobe uses both direct observation of nuclear reactions induced by deuterons and X ray emission induced by protons or deuterons. Thanks to these techniques, concentration profiles of the main elements (C, N, P, Ca...) contained in different parts of healthy teeth (enamel, dentine and cementum) are drawn in control zones and laser irradiated zones. The results obtained show that important perturbations appear during the irradiation by the laser beam; we observe successively, depleted zones in carbon and nitrogen which contain calcium and phosphorus and hypomineralized zones which contain organic material. 10 refs [fr

  8. Effect of proton and gamma irradiation on human lung carcinoma cells: Gene expression, cell cycle, cell death, epithelial–mesenchymal transition and cancer-stem cell trait as biological end points

    Energy Technology Data Exchange (ETDEWEB)

    Narang, Himanshi, E-mail: narangh@barc.gov.in [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Kumar, Amit [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Bhat, Nagesh [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Pandey, Badri N.; Ghosh, Anu [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2015-10-15

    Highlights: • Biological effectiveness of proton and gamma irradiation is compared in A549 cells. • Proton irradiation is two times more cytotoxic than gamma irradiation. • It alters ten times more number of early genes, as observed by microarray study. • It does not enhance cell migration, invasion and adhesion, unlike gamma irradiation. • It was more effective in reducing the percentage of cancer stem cell like cells. - Abstract: Proton beam therapy is a cutting edge modality over conventional gamma radiotherapy because of its physical dose deposition advantage. However, not much is known about its biological effects vis-a-vis gamma irradiation. Here we investigated the effect of proton- and gamma- irradiation on cell cycle, death, epithelial-mesenchymal transition (EMT) and “stemness” in human non-small cell lung carcinoma cells (A549). Proton beam (3 MeV) was two times more cytotoxic than gamma radiation and induced higher and longer cell cycle arrest. At equivalent doses, numbers of genes responsive to proton irradiation were ten times higher than those responsive to gamma irradiation. At equitoxic doses, the proton-irradiated cells had reduced cell adhesion and migration ability as compared to the gamma-irradiated cells. It was also more effective in reducing population of Cancer Stem Cell (CSC) like cells as revealed by aldehyde dehydrogenase activity and surface phenotyping by CD44{sup +}, a CSC marker. These results can have significant implications for proton therapy in the context of suppression of molecular and cellular processes that are fundamental to tumor expansion.

  9. Numerically simulated and experimentally obtained X-ray section topographs of a spherical strain field in a floating zone silicon crystal

    International Nuclear Information System (INIS)

    Okitsu, Kouhei; Iida, Satoshi; Sugita, Yoshimitsu; Takeno, Hiroshi; Yagou, Yasuyoshi; Kawata, Hiroshi.

    1992-01-01

    An undoped floating zone (FZ) silicon crystal has been investigated by synchrotron X-radiation section topography with high-order reflections up to 14 14 0. Numerically simulated topographs based on the Takagi-Taupin equations were in good agreement with experimental distorted patterns when a spherical strain field was assumed in the crystal. The volume change of the lattice caused by the strain center was estimated to correspond to a sphere with a radius of 10 μm. (author)

  10. Effects of proton irradiation on structure of NdFeB permanent magnets studied by X-ray diffraction and X-ray absorption fine structure

    International Nuclear Information System (INIS)

    Yang, L.; Zhen, L.; Xu, C.Y.; Sun, X.Y.; Shao, W.Z.

    2011-01-01

    The effects of proton irradiation on the structure of NdFeB permanent magnet were investigated by X-ray diffraction and X-ray absorption fine structure (XAFS). The results reveal that proton irradiation has no effect on the long-range structure, but significantly affects the atomic local structure of the NdFeB magnet. The alignment degree of the magnet decreases and the internal stress of the lattice increases after proton irradiation. XAFS results show that the coordination number of Fe-Nd in the first neighboring coordination shell of the Fe atoms decreases and the disorder degree increases.

  11. Effects of proton irradiation on structure of NdFeB permanent magnets studied by X-ray diffraction and X-ray absorption fine structure

    Energy Technology Data Exchange (ETDEWEB)

    Yang, L. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Zhen, L., E-mail: lzhen@hit.edu.c [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Xu, C.Y.; Sun, X.Y.; Shao, W.Z. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2011-01-15

    The effects of proton irradiation on the structure of NdFeB permanent magnet were investigated by X-ray diffraction and X-ray absorption fine structure (XAFS). The results reveal that proton irradiation has no effect on the long-range structure, but significantly affects the atomic local structure of the NdFeB magnet. The alignment degree of the magnet decreases and the internal stress of the lattice increases after proton irradiation. XAFS results show that the coordination number of Fe-Nd in the first neighboring coordination shell of the Fe atoms decreases and the disorder degree increases.

  12. Establishing Cost-Effective Allocation of Proton Therapy for Breast Irradiation

    International Nuclear Information System (INIS)

    Mailhot Vega, Raymond B.; Ishaq, Omar; Raldow, Ann; Perez, Carmen A.; Jimenez, Rachel; Scherrer-Crosbie, Marielle; Bussiere, Marc; Taghian, Alphonse; Sher, David J.; MacDonald, Shannon M.

    2016-01-01

    Purpose: Cardiac toxicity due to conventional breast radiation therapy (RT) has been extensively reported, and it affects both the life expectancy and quality of life of affected women. Given the favorable oncologic outcomes in most women irradiated for breast cancer, it is increasingly paramount to minimize treatment side effects and improve survivorship for these patients. Proton RT offers promise in limiting heart dose, but the modality is costly and access is limited. Using cost-effectiveness analysis, we provide a decision-making tool to help determine which breast cancer patients may benefit from proton RT referral. Methods and Materials: A Markov cohort model was constructed to compare the cost-effectiveness of proton versus photon RT for breast cancer management. The model was analyzed for different strata of women based on age (40 years, 50 years, and 60 years) and the presence or lack of cardiac risk factors (CRFs). Model entrants could have 1 of 3 health states: healthy, alive with coronary heart disease (CHD), or dead. Base-case analysis assumed CHD was managed medically. No difference in tumor control was assumed between arms. Probabilistic sensitivity analysis was performed to test model robustness and the influence of including catheterization as a downstream possibility within the health state of CHD. Results: Proton RT was not cost-effective in women without CRFs or a mean heart dose (MHD) <5 Gy. Base-case analysis noted cost-effectiveness for proton RT in women with ≥1 CRF at an approximate minimum MHD of 6 Gy with a willingness-to-pay threshold of $100,000/quality-adjusted life-year. For women with ≥1 CRF, probabilistic sensitivity analysis noted the preference of proton RT for an MHD ≥5 Gy with a similar willingness-to-pay threshold. Conclusions: Despite the cost of treatment, scenarios do exist whereby proton therapy is cost-effective. Referral for proton therapy may be cost-effective for patients with ≥1 CRF in cases for which

  13. Establishing Cost-Effective Allocation of Proton Therapy for Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Mailhot Vega, Raymond B.; Ishaq, Omar [Department of Radiation Oncology, NYU School of Medicine, New York, New York (United States); Raldow, Ann [Radiation Oncology Program, Harvard University, Boston, Massachusetts (United States); Perez, Carmen A. [Department of Radiation Oncology, NYU School of Medicine, New York, New York (United States); Jimenez, Rachel [Department of Radiation Oncology, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts (United States); Scherrer-Crosbie, Marielle [Cardiovascular Research Center, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts (United States); Bussiere, Marc; Taghian, Alphonse [Department of Radiation Oncology, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts (United States); Sher, David J. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, San Antonio, Texas (United States); MacDonald, Shannon M., E-mail: smacdonald@partners.org [Department of Radiation Oncology, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2016-05-01

    Purpose: Cardiac toxicity due to conventional breast radiation therapy (RT) has been extensively reported, and it affects both the life expectancy and quality of life of affected women. Given the favorable oncologic outcomes in most women irradiated for breast cancer, it is increasingly paramount to minimize treatment side effects and improve survivorship for these patients. Proton RT offers promise in limiting heart dose, but the modality is costly and access is limited. Using cost-effectiveness analysis, we provide a decision-making tool to help determine which breast cancer patients may benefit from proton RT referral. Methods and Materials: A Markov cohort model was constructed to compare the cost-effectiveness of proton versus photon RT for breast cancer management. The model was analyzed for different strata of women based on age (40 years, 50 years, and 60 years) and the presence or lack of cardiac risk factors (CRFs). Model entrants could have 1 of 3 health states: healthy, alive with coronary heart disease (CHD), or dead. Base-case analysis assumed CHD was managed medically. No difference in tumor control was assumed between arms. Probabilistic sensitivity analysis was performed to test model robustness and the influence of including catheterization as a downstream possibility within the health state of CHD. Results: Proton RT was not cost-effective in women without CRFs or a mean heart dose (MHD) <5 Gy. Base-case analysis noted cost-effectiveness for proton RT in women with ≥1 CRF at an approximate minimum MHD of 6 Gy with a willingness-to-pay threshold of $100,000/quality-adjusted life-year. For women with ≥1 CRF, probabilistic sensitivity analysis noted the preference of proton RT for an MHD ≥5 Gy with a similar willingness-to-pay threshold. Conclusions: Despite the cost of treatment, scenarios do exist whereby proton therapy is cost-effective. Referral for proton therapy may be cost-effective for patients with ≥1 CRF in cases for which

  14. Investigations of ultrafast charge dynamics in laser-irradiated targets by a self probing technique employing laser driven protons

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, H. [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom); Kar, S., E-mail: s.kar@qub.ac.uk [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom); Cantono, G. [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom); Department of Physics “E. Fermi”, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Research Unit Adriano Gozzini, via G. Moruzzi 1, Pisa 56124 (Italy); Nersisyan, G. [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom); Brauckmann, S. [Institut für Laser-und Plasmaphysik, Heinrich-Heine-Universität, Düsseldorf (Germany); Doria, D.; Gwynne, D. [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom); Macchi, A. [Department of Physics “E. Fermi”, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Research Unit Adriano Gozzini, via G. Moruzzi 1, Pisa 56124 (Italy); Naughton, K. [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom); Willi, O. [Institut für Laser-und Plasmaphysik, Heinrich-Heine-Universität, Düsseldorf (Germany); Lewis, C.L.S.; Borghesi, M. [School of Mathematics and Physics, Queen' s University Belfast, BT7 1NN (United Kingdom)

    2016-09-01

    The divergent and broadband proton beams produced by the target normal sheath acceleration mechanism provide the unique opportunity to probe, in a point-projection imaging scheme, the dynamics of the transient electric and magnetic fields produced during laser-plasma interactions. Commonly such experimental setup entails two intense laser beams, where the interaction produced by one beam is probed with the protons produced by the second. We present here experimental studies of the ultra-fast charge dynamics along a wire connected to laser irradiated target carried out by employing a ‘self’ proton probing arrangement – i.e. by connecting the wire to the target generating the probe protons. The experimental data shows that an electromagnetic pulse carrying a significant amount of charge is launched along the wire, which travels as a unified pulse of 10s of ps duration with a velocity close to speed of light. The experimental capabilities and the analysis procedure of this specific type of proton probing technique are discussed. - Highlights: • Prompt charging of laser irradiated target generates ultra-short EM pulses. • Its ultrafast propagation along a wire was studied by self-proton probing technique. • Self-proton probing technique is the proton probing with one laser pulse. • Pulse temporal profile and speed along the wire were measured with high resolution.

  15. Electronic properties of semiinsulating GaAs irradiated by protons

    CERN Document Server

    Brudnyj, V N

    2001-01-01

    The n-to-p-type transformation of the conductivity and the decrease of resistivity (rho) down to 10 sup 2 Ohm cm (300 K) have been observed in a semi insulating GaAs (rho approx = (3-4) 10 sup 8 Ohm cm) upon proto n (5 MeV) bombardment with the dose up to D = 2 x 10 sup 1 sup 7 cm sup - sup 2. The temperature dependence of rho in heavy irradiated samples indicates that the conductivity is determined by the electron hopping within the temperature range (400-120) K and by the changeable hopping length at T <= 120 K. In proton irradiated low resistivity samples, the electronic switching effects have been revealed near 20 K. Isochronal annealing of the radiation-induced defects is investigated in the temperature range (20-750) deg C

  16. The Columbia University proton-induced soft x-ray microbeam.

    Science.gov (United States)

    Harken, Andrew D; Randers-Pehrson, Gerhard; Johnson, Gary W; Brenner, David J

    2011-09-15

    A soft x-ray microbeam using proton-induced x-ray emission (PIXE) of characteristic titanium (K(α) 4.5 keV) as the x-ray source has been developed at the Radiological Research Accelerator Facility (RARAF) at Columbia University. The proton beam is focused to a 120 μm × 50 μm spot on the titanium target using an electrostatic quadrupole quadruplet previously used for the charged particle microbeam studies at RARAF. The proton induced x-rays from this spot project a 50 μm round x-ray generation spot into the vertical direction. The x-rays are focused to a spot size of 5 μm in diameter using a Fresnel zone plate. The x-rays have an attenuation length of (1/e length of ~145 μm) allowing more consistent dose delivery across the depth of a single cell layer and penetration into tissue samples than previous ultra soft x-ray systems. The irradiation end station is based on our previous design to allow quick comparison to charged particle experiments and for mixed irradiation experiments.

  17. A comparison of 4 MeV Proton and Co-60 gamma irradiation induced degradation in the electrical characteristics of N-channel MOSFETs

    Energy Technology Data Exchange (ETDEWEB)

    Anjum, Arshiya; Vinayakprasanna, N.H.; Pradeep, T.M. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India); Pushpa, N. [Department of PG Studies in Physics, JSS College, Ooty Road, Mysore 570025 (India); Krishna, J.B.M. [IUC-DAE CSR, Kolkota 700098 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India)

    2016-07-15

    N-channel depletion MOSFETs were irradiated with 4 MeV Proton and Co-60 gamma radiation in the dose range of 100 krad(Si) to 100 Mrad(Si). The electrical characteristics of MOSFET such as threshold voltage (V{sub th}), density of interface trapped charges (ΔN{sub it}), density of oxide trapped charges (ΔN{sub ot}), transconductance (g{sub m}), mobility (μ), leakage current (I{sub L}) and drain saturation current (I{sub D} {sub Sat}) were studied as a function of dose. A considerable increase in ΔN{sub it} and ΔN{sub ot} and decrease in V{sub th,}g{sub m}, μ, and I{sub D} {sub Sat} was observed after irradiation. The results of 4 MeV Proton irradiation were compared with that of Co-60 gamma radiation and it is found that the degradation is more for the devices irradiated with 4 MeV Protons when compared with the Co-60 gamma radiation. This indicates that Protons induce more trapped charges in the field oxide region when compared to the gamma radiation.

  18. Sorption technique of separation of thallium-201 from proton-irradiated thallium

    International Nuclear Information System (INIS)

    Deptula, Cz.; Zajtseva, N.G.; Mikolaevskij, S.; Khalkin, V.A.

    1989-01-01

    A sorption technique is developed for radiochemical separation of thallium-201 from proton-irradiated targets of metallic thallium. The technique consists in separation of 201 Pb and 201 Tl in the column with ammonium 12-molybdophosphate fixed in the matrix of porous Teflon (AMP-sorbent). The chemical yield of radiothallium is 98 %, the duration of chemical procedures is 2.5-3 hours. 21 refs.; 1 fig.; 1 tab

  19. Depletion voltage studies on n-in-n MCz silicon diodes after irradiation with 70 MeV protons

    CERN Document Server

    Holmkvist, William

    2014-01-01

    Silicon detectors is the main component in the pixel detectors in the ATLAS experiment at CERN in order to detect the particles and recreate their tracks after a proton-proton collision. One criteria on these detectors is to be able to operate in the high radiation field close to the particle collision. The usual behavior of the silicon detectors is that they get type inverted and an increase in the depletion voltage can be seen after exposed to significant amounts of radiation. In contrast n-type Magnetic Czochralski (MCz) silicon doesn’t follow FZ silicons pattern of getting type inverted when it comes to high energy particle irradiation, in the range of GeV. However it was observed that MCz silicon diodes that had been irradiated with 23 MeV protons followed the FZ silicon behavior and did type invert. The aim of the project is to find out how the depletion voltage of MCz silicon changes after being irradiated by 70 MeV at fluencies of 1E13, 1E14 and 5E14 neq/cm2, to give a further insight of at what en...

  20. Recovery of hafnium radioisotopes from a proton irradiated tantalum target

    International Nuclear Information System (INIS)

    Taylor, W.A.; Garcia, J.G.; Hamilton, V.T.; Heaton, R.C.; Jamriska, D.J.; Ott, M.A.; Philips, D.R.; Radzinski, S.D.

    1998-01-01

    The 178m2 Hf nucleus, with its long half-life (31 y) and high-spin isomeric state (16 + ) is desired for new and exotic nuclear physics studies. The Los Alamos Radioisotope Program irradiated a kilogram of natural tantalum at the Los Alamos Meson Physics Facility in early 1981. After fifteen years of decay, this target was ideal for the recovery of 178m2 Hf. There was more than a millicurie of 178m2 Hf produced during this irradiation and there has been a sufficient period of time for most of the other hafnium radioisotopes to decayed away. Traditionally, separation techniques for recovering hafnium isotopes from tantalum targets employ solvent extractions with reagents that are considered hazardous. These techniques are no longer condoned because they generate a mixed-waste (radioactive and hazardous components) that can not be treated for disposal. In this paper we describe a new and unique procedure for the recovery of hafnium radioisotopes from a highly radioactive, proton irradiated, tantalum target using reagents that do not contribute a hazardous waste component. (author)

  1. Radiosensitizing effect of nitric oxide in tumor cells and experimental tumors irradiated with gamma rays and proton beams; Efecto radiosensibilizador del oxido nitrico en celulas tumorales y en tumores experimentales irradiados con radiacion gamma y con haces de protones

    Energy Technology Data Exchange (ETDEWEB)

    Policastro, Lucia L; Duran, Hebe; Molinari, Beatriz L [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia; Schuff, Juan A; Kreiner, Andres J; Burlon, Alejandro A; Debray, Mario E; Kesque, Jose M; Ozafran, Mabel J; Vazquez, Monica E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Fisica; Davidson, Jorge; Davidson, Miguel [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina); Somacal, Hector R; Valda, Alejandro A [Universidad Nacional de General San Martin , Villa Ballester (Argentina). Escuela de Ciencia y Tecnologia

    2003-07-01

    Nitric oxide (NO) has been reported to be a radiosensitizer of mammalian cells under hypoxic conditions. In a previous study, we demonstrated an enhancement in radiation response induced by NO in mouse tumor cells under aerobic conditions, with an increasing effect as a function of malignancy. The aim of the present study was to evaluate the effect of NO in tumor cells and in experimental tumors irradiated with {gamma} rays and proton beams. Irradiations were performed with a {sup 137}Cs {gamma} source and with proton beams generated by the TANDAR accelerator. Tumor cells were treated with the NO donor DETA-NO and the sensitizer enhancement ratio (SER) was calculated using the {alpha} parameter of the survival curve fitted to the linear-quadratic model. Tumor cells irradiated with protons were radio sensitized by DETA-NO only in the more malignant cells irradiated with low LET protons (2.69{+-}0.08 keV/{mu}m). For higher LET protons there were no radiosensitizing effect. For human tumor cells pre-treated with DETA-NO and irradiated with {gamma} rays, a significantly greater effect was demonstrated in the malignant cells (MCF-7) as compared with the near normal cells (HBL-100). Moreover, a significant decrease in tumor growth was demonstrated in mice pre-treated with the NO donor spermine and irradiated with {gamma} rays and low LET protons as compared with mice irradiated without pre-treatment with the NO donor. In conclusion, we demonstrated a differential effect of NO as a radiosensitizer of malignant cells, both with {gamma} rays and low LET protons. This selectivity, coupled to the in vivo inhibition of tumor growth, is of great interest for the potential use of NO releasing agents in radiotherapy. (author)

  2. A Method to Simulate the Observed Surface Properties of Proton Irradiated Silicon Strip Sensors

    CERN Document Server

    Peltola, Timo Hannu Tapani

    2014-01-01

    A defect model of Synopsys Sentaurus TCAD simulation package for the bulk properties of proton irradiated devices has been producing simulations closely matching to measurements of silicon strip detectors. However, the model does not provide the expected behavior due to the fluence increased surface damage. The solution requires an approach that does not affect the accurate bulk properties produced by the proton model, but only adds to it the required radiation induced properties close to the surface. These include the observed position dependency of the strip detector's...

  3. Direct observation of the point-defect structure of depleted-zones in ion-irradiated metals

    International Nuclear Information System (INIS)

    Wei, C.

    1978-01-01

    The point-defect structure of individual depleted zones has been studied systematically. Four-pass zone-refined tungsten field-ion microscope (FIM) specimens were irradiated in-situ at 10 K with 30 keV Cr + , Mo + , or W + ions to a total dose of (2 to 10) x 10 12 ion cm -2 and examined by the pulse field-evaporation technique at 10 K. The experimental conditions were such that each depleted zone was created by a single incident-ion. The number of vacant lattice sites within a depleted zone was compared with a modified Kinchin--Pease model. The radial distribution function was determined for each depleted zone; it was found that the vacant lattice sites within the volume of each depleted zone tended to exist in a highly clustered state. It was found that the diameter D of each depleted zone was described by the equation D approximately equal to [y 2 ]/sup 1 / 2 / where [y 2 ]/sup 1 / 2 / is the second moment of the theoretical distribution curve, of the fraction of incident ion energy deposited in atom motion, transverse to the direction of the incident ion-beam. The spatial distribution of self-interstitial atoms (SIAs) in a specimen irradiated with 30 keV Cr + ions and in a specimen irradiated with 18 keV Au + ions, at 10 K, was determined. A low bound to the average range of replacement collision sequences (RCSs) was found to be 175 +- 85 A. A detailed FIM study was also made of the vacancy structure of a (220) platelet created by a single 30 keV W + ion in a platinum-4.0 at. % gold alloy; the specimen was irradiated at 40 K and then isochronally warmed to 100 K. The (220) platelet was found to consist of 31 vacant lattice sites, lying in four (220) planes, and clustered in a disc-shaped region which is approximately 20 A in diameter. It was suggested that prismatic dislocation loops lying on (220) type planes in ion or fast neutron irradiated platinum can form as a result of the direct collapse of (220) type vacancy platelets

  4. Low energy proton irradiation effects on InP/InGaAs DHBTs and InP-base frequency dividers

    Science.gov (United States)

    Zhang, Xingyao; Li, Yudong; Guo, Qi; Feng, Jie

    2018-03-01

    InP/InGaAs DHBTs and frequency dividers are irradiated by low energy proton, and displacement damage effect of the devices are analyzed. InP/InGaAs DHBTs has been made DC characteristics measurements, and the function measurement for frequency dividers has been done both before and after proton irradiation. The breakdown voltage of InP DHBTs drop to 3.7V When the fluence up to 5x1013 protons/cm2. Meanwhile, the function of frequency dividers get out of order. Degradation of DC characteristics of DHBTs are due to the radiation-induced defects in the quasi neutral base and the space charge region of base-collector and base-emitter junctions. The performance deterioration of DHBTs induce the fault of frequency dividers, and prescaler may be the most sensitive circuit.

  5. Influence of proton irradiation on the photochromism

    International Nuclear Information System (INIS)

    Lee, I. J.; Kim, D. E.; Kang, T. W.; Kim, N. Y.

    2008-04-01

    The objectives of this study are to extend our knowledge on the radiochromic reaction mechanism of photochromic compounds and to accumulate the basic data needed for the development of a low-cost radiochromic film dosimeter. The characteristics of the radiochromic reaction of SPO, were studied by UV-Vis and chromatographic methods. The results of the radiochromic reaction was compared with the effects of UV light on photochromic reaction of SPO. The basic data for selecting the proper materials and conditions were also obtained. Upon the proton irradiation, SPO decomposes into two chemicals (1 and 2). 1 is contains indoline group and 2 contains phenanthrene group. 2 absorbs at 480 nm and has acidic character. By the UV irradiation, SPO also decomposes to give the same products as the radiochromic reaction. Depending on the solvent trans-PMC·HCl or cis-PMC·HCl complex was produced upon the addition of HCl on SPO solution and two complexes seemed to be unstable in a given condition. It seems that 1x10 -3 M SPO/ethanol solution is very suitable system for the radiochromic dosimeter in the fluence range of 8x10 11 ∼ 2x10 13 ions/cm 2 . SPO/acetonitrile and SPO/PS system were also good candidates for the dosimeter application.

  6. A coupled RL and transport model for mixed-field proton irradiation of Al2O3:C

    DEFF Research Database (Denmark)

    Greilich, Steffen; Edmund, Jens Morgenthaler; Jain, Mayank

    2008-01-01

    effects and inelastic hadronic scattering occur in proton therapy dosimetry. To investigate these aspects in relation to our system, we have combined simulation of particle transportation with a luminescence generation code based on track structure theory. The model was found to qualitatively reproduce...... the main features in experimental data from proton irradiations. (c) 2008 Elsevier Ltd. All rights reserved....

  7. Evidence for plasma effect on charge collection efficiency in proton irradiated GaAs detectors

    CERN Document Server

    Nava, F; Canali, C; Vittone, E; Polesello, P; Biggeri, U; Leroy, C

    1999-01-01

    The radiation damage in 100 mu m thick Schottky diodes made on semi-insulating undoped GaAs materials, were studied using alpha-, beta-, proton- and gamma-spectroscopy as well as I-V measurements. The results have been analysed within the framework of the Hecht model to investigate the influence of the plasma produced by short-range strongly ionising particles on the detector performance after 24 GeV proton irradiation. It has been found that with the mean free drift lengths for electrons and holes determined from alpha-spectra in overdepleted detectors, the charge collection efficiency for beta-particles, cce subbeta, is well predicted in the unirradiated detectors, while in the most irradiated ones, the cce subbeta is underestimated by more than 40%. The observed disagreement can be explained by assuming that the charge carrier recombination in the plasma region of such detectors, becomes significant.

  8. Development of Radiation Hard Radiation Detectors, Differences between Czochralski Silicon and Float Zone Silicon

    CERN Document Server

    Tuominen, Eija

    2012-01-01

    The purpose of this work was to develop radiation hard silicon detectors. Radiation detectors made ofsilicon are cost effective and have excellent position resolution. Therefore, they are widely used fortrack finding and particle analysis in large high-energy physics experiments. Silicon detectors willalso be used in the CMS (Compact Muon Solenoid) experiment that is being built at the LHC (LargeHadron Collider) accelerator at CERN (European Organisation for Nuclear Research). This work wasdone in the CMS programme of Helsinki Institute of Physics (HIP).Exposure of the silicon material to particle radiation causes irreversible defects that deteriorate theperformance of the silicon detectors. In HIP CMS Programme, our approach was to improve theradiation hardness of the silicon material with increased oxygen concentration in silicon material. Westudied two different methods: diffusion oxygenation of Float Zone silicon and use of high resistivityCzochralski silicon.We processed, characterised, tested in a parti...

  9. Proton-irradiation technology for high-frequency high-current silicon welding diode manufacturing

    Science.gov (United States)

    Lagov, P. B.; Drenin, A. S.; Zinoviev, M. A.

    2017-05-01

    Different proton irradiation regimes were tested to provide more than 20 kHz-frequency, soft reverse recovery “snap-less” behavior, low forward voltage drop and leakage current for 50 mm diameter 7 kA/400 V welding diode Al/Si/Mo structure. Silicon diode with such parameters is very suitable for high frequency resistance welding machines of new generation for robotic welding.

  10. Low-temperature positron-lifetime studies of proton-irradiated silicon

    DEFF Research Database (Denmark)

    Mäkinen, S.; Rajainmäki, H.; Linderoth, Søren

    1990-01-01

    The positron-lifetime technique has been used to identify defects created in high-purity single-crystal silicon by irradiation with 12-MeV protons at 15 K, and the evolution of the defects has been studied by subsequent annealings between 20 and 650 K. Two clear annealing steps were seen...... in the samples, the first starting at 100 K and the other at 400 K. The first is suggested to be a result of the migration of free, negatively charged monovacancies, and the second is connected to the annealing of some vacancy-impurity complexes, probably negatively charged vacancy-oxygen pairs. The specific...

  11. Planar silicon sensors for the CMS Tracker upgrade

    CERN Document Server

    Junkes, Alexandra

    2013-01-01

    The CMS tracker collaboration has initiated a large material investigation and irradiation campaign to identify the silicon material and design that fulfills all requirements for detectors for the high-luminosity phase of the Large Hadron Collider (HL-LHC).A variety of silicon p-in-n and n-in-p test-sensors made from Float Zone, Deep-Diffused FZ and Magnetic Czochralski materials were manufactured by one single industrial producer, thus guaranteeing similar conditions for the production and design of the test-structures. Properties of different silicon materials and design choices have been systematically studied and compared.The samples have been irradiated with 1 MeV neutrons and protons corresponding to maximal fluences as expected for the positions of detector layers in the future tracker. Irradiations with protons of different energies (23 MeV and 23 GeV) have been performed to evaluate the energy dependence of the defect generation in oxygen rich material. All materials have been characterized before an...

  12. Transmission electron microscope study of neutron irradiation-induced defects in silicon

    International Nuclear Information System (INIS)

    Oshima, Ryuichiro; Kawano, Tetsuya; Fujimoto, Ryoji

    1994-01-01

    Commercial Czochralski-grown silicon (Cz-Si) and float-zone silicon (Fz-Si) wafers were irradiated with fission neutrons at various fluences from 10 19 to 10 22 n/cm 2 at temperatures ranging from 473 K to 1043 K. The irradiation induced defect structures were examined by transmission electron microscopy and ultra high voltage electron microscopy, which were compared with Marlowe code computer simulation results. It was concluded that the vacancy-type damage structure formed at 473 K were initiated from collapse of vacancy-rich regions of cascades, while interstitial type defect clusters formed by irradiation above 673 K were associated with interstitial oxygen atoms and free interstitials which diffused out of the cascades. Complex defect structures were identified to consist of {113} and {111} planar faults by the parallel beam illumination diffraction analysis. (author)

  13. Biological Effects of Neutron and Proton Irradiations. Vol. II. Proceedings of the Symposium on Biological Effects of Neutron Irradiations

    International Nuclear Information System (INIS)

    1964-01-01

    During recent years the interest in biological effects caused by neutrons has been increasing steadily as a result of the rapid development of neutron technology and the great number of neutron sources being used. Neutrons, because of their specific physical characteristics and biological effects, form a special type of radiation hazard but, at the same time, are a prospective tool for applied radiobiology. This Symposium, held in Brookhaven at the invitation of the United States Government from 7-11 October 1963, provided an opportunity for scientists to discuss the experimental information at present available on the biological action of neutrons and to evaluate future possibilities. It was a sequel to the Symposium on Neutron Detection, Dosimetry and Standardization, which was organized by the International Atomic Energy Agency in December 1962 at Harwell. The Symposium was attended by 128 participants from 17 countries and 6 international organizations. Fifty-four papers were presented. The following subjects were discussed in various sessions: (1) Dosimetry. Estimation of absorbed dose of neutrons in biological material. (2) Biological effects of high-energy protons. (3) Cellular and genetic effects. (4) Pathology of neutron irradiation, including acute and chronic radiation syndromes (mortality, anatomical and histological changes, biochemical and metabolic disturbances) and delayed consequences. (5) Relative biological effectiveness of neutrons evaluated by different biological tests. A Panel on Biophysical Considerations in Neutron Experimentation, with special emphasis on informal discussions, was organized during the Symposium. The views of the Panel are recorded in Volume II of the Proceedings. Many reports were presented on the important subject of the relative effectiveness of the biological action of neutrons, as well as on the general pathology of neutron irradiation and the cellular and genetic effects related to it. Three survey papers considered

  14. Suppressing the memory state of floating gate transistors with repeated femtosecond laser backside irradiations

    Science.gov (United States)

    Chambonneau, Maxime; Souiki-Figuigui, Sarra; Chiquet, Philippe; Della Marca, Vincenzo; Postel-Pellerin, Jérémy; Canet, Pierre; Portal, Jean-Michel; Grojo, David

    2017-04-01

    We demonstrate that infrared femtosecond laser pulses with intensity above the two-photon ionization threshold of crystalline silicon induce charge transport through the tunnel oxide in floating gate Metal-Oxide-Semiconductor transistor devices. With repeated irradiations of Flash memory cells, we show how the laser-produced free-electrons naturally redistribute on both sides of the tunnel oxide until the electric field of the transistor is suppressed. This ability enables us to determine in a nondestructive, rapid and contactless way the flat band and the neutral threshold voltages of the tested device. The physical mechanisms including nonlinear ionization, quantum tunneling of free-carriers, and flattening of the band diagram are discussed for interpreting the experiments. The possibility to control the carriers in memory transistors with ultrashort pulses holds promises for fast and remote device analyses (reliability, security, and defectivity) and for considerable developments in the growing field of ultrafast microelectronics.

  15. Radiation-induced conductivity of doped silicon in response to photon, proton and neutron irradiation

    International Nuclear Information System (INIS)

    Kishimoto, N.; Amekura, H.; Plaksin, O.A.; Stepanov, V.A.

    2000-01-01

    The opto-electronic performance of semiconductors during reactor operation is restricted by radiation-induced conductivity (RIC) and the synergistic effects of neutrons/ions and photons. The RICs of Si due to photons, protons and pulsed neutrons have been evaluated, aiming at radiation correlation. Protons of 17 MeV with an ionizing dose rate of 10 3 Gy/s and/or photons (hν=1.3 eV) were used to irradiate impurity-doped Si (2x10 16 B atoms/cm 3 ) at 300 and 200 K. Proton-induced RIC (p-RIC) and photoconductivity (PC) were intermittently detected in an accelerator device. Neutron-induced RIC (n-RIC) was measured for the same Si in a pulsed fast-fission reactor, BARS-6, with a 70-μs pulse of 2x10 12 n/cm 2 (E>0.01 MeV) and a dose rate of up to 6x10 5 Gy/s. The neutron irradiation showed a saturation tendency in the flux dependence at 300 K due to the strong electronic excitation. Normalization of the electronic excitation, including the pulsed regime, gave a fair agreement among the different radiation environments. Detailed comparison among PC, p-RIC and n-RIC is discussed in terms of radiation correlation including the in-pile condition

  16. Mechanical properties and microstructures of copper, gold and palladium single crystals irradiated with 600 MeV protons

    International Nuclear Information System (INIS)

    Dai Yong.

    1995-01-01

    In the present work, the defect microstructures and hardening effects produced by 600 MeV proton irradiation in Cu, Pd and Au single crystals have been studied at room temperature. The defect microstructures in the irradiated Cu have been investigated by using transmission electron microscopy (TEM) in a dose range from 9.7x10 -4 to 4.6x10 -2 dpa. It has been observed that about 90% of the total defect clusters are stacking fault tetrahedra (SFT's). This fraction is independent of the thickness of the foil up to about 130 nm. The irradiation defect cluster densities obtained are in agreement with previous published results of high energy proton irradiation. With the present data at medium doses, the dose dependence of the defect cluster density, in high energy proton irradiated Cu, has been well established. A comparison between the results of Cu irradiated with high energy protons, fusion neutrons and fission neutrons indicates that there is no difference in defect cluster densities produced by these particle irradiations when the results are compared on the basis of dpa. The data compiled can be fitted within a band which shows that the defect cluster density starts to saturate at a value of about 4x10 23 m -3 . A large transition dose range between the linear dependence to the saturation is located between 3x10 -3 and 1x10 -1 dpa. The defect cluster size distribution measured under weak beam dark field (WBDF) imaging conditions with (g,6g) (WBDF(g,6g)), g=200, shows that the most probable size is between 1.5 and 2 nm and the mean size is about 2 nm independent of the dose. This result is also in agreement with published results. The defect structure in Au at dose of 1.1x10 -1 dpa has been observed. It shows that about 85% of the total defect clusters are SFT's. There are no grouped defect clusters, which may probably be due to the fact that the defect cluster density (5.1x10 23 ) has already saturated at this high dose. The most probable defect cluster size is

  17. Proton-irradiation technology for high-frequency high-current silicon welding diode manufacturing

    International Nuclear Information System (INIS)

    Lagov, P B; Drenin, A S; Zinoviev, M A

    2017-01-01

    Different proton irradiation regimes were tested to provide more than 20 kHz-frequency, soft reverse recovery “snap-less” behavior, low forward voltage drop and leakage current for 50 mm diameter 7 kA/400 V welding diode Al/Si/Mo structure. Silicon diode with such parameters is very suitable for high frequency resistance welding machines of new generation for robotic welding. (paper)

  18. Three-dimensional modelling of thermal stress in floating zone silicon crystal growth

    Science.gov (United States)

    Plate, Matiss; Krauze, Armands; Virbulis, Jānis

    2018-05-01

    During the growth of large diameter silicon single crystals with the industrial floating zone method, undesirable level of thermal stress in the crystal is easily reached due to the inhomogeneous expansion as the crystal cools down. Shapes of the phase boundaries, temperature field and elastic material properties determine the thermal stress distribution in the solid mono crystalline silicon during cylindrical growth. Excessive stress can lead to fracture, generation of dislocations and altered distribution of intrinsic point defects. Although appearance of ridges on the crystal surface is the decisive factor of a dislocation-free growth, the influence of these ridges on the stress field is not completely clear. Here we present the results of thermal stress analysis for 4” and 5” diameter crystals using a quasi-stationary three dimensional mathematical model including the material anisotropy and the presence of experimentally observed ridges which cannot be addressed with axis-symmetric models. The ridge has a local but relatively strong influence on thermal stress therefore its relation to the origin of fracture is hypothesized. In addition, thermal stresses at the crystal rim are found to increase for a particular position of the crystal radiation reflector.

  19. Recovery of damage in rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays

    Science.gov (United States)

    Brucker, G. J.; Van Gunten, O.; Stassinopoulos, E. G.; Shapiro, P.; August, L. S.; Jordan, T. M.

    1983-01-01

    This paper reports on the recovery properties of rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays. The results indicated that complex recovery properties controlled the damage sensitivities of the tested parts. The results also indicated that damage sensitivities depended on dose rate, total dose, supply bias, gate bias, transistor type, radiation source, and particle energy. The complex nature of these dependencies make interpretation of LSI device performance in space (exposure to entire electron and proton spectra) difficult, if not impossible, without respective ground tests and analyses. Complete recovery of n-channel shifts was observed, in some cases within hours after irradiation, with equilibrium values of threshold voltages greater than their pre-irradiation values. This effect depended on total dose, radiation source, and gate bias during exposure. In contrast, the p-channel shifts recovered only 20 percent within 30 days after irradiation.

  20. Mechanical-property changes of structural composite materials after low-temperature proton irradiation: Implications for use in SSC magnet systems

    International Nuclear Information System (INIS)

    Morena, J.; Snead, C.L. Jr.; Czajkowski, C.; Skaritka, J.

    1993-01-01

    Longterm physical, mechanical, electrical, and other properties of advanced composites, plastics, and other polymer materials are greatly affected by high-energy proton, neutron, electron, and gamma radiation. The effects of high-energy particles on materials is a critical design parameter to consider when choosing polymeric structural, nonstructural, and elastomeric matrix resin systems. Polymer materials used for filled resins, laminates, seals, gaskets, coatings, insulation and other nonmetallic components must be chosen carefully, and reference data viewed with caution. Most reference data collected in the high-energy physics community to date reflects material property degradation using other than proton irradiations. In most instances, the data were collected for room-temperature irradiations, not 4.2 K or other cryogenic temperatures, and at doses less than 10 8 --10 9 Rad. Energetic proton (and the accompanying spallation-product particles) provide good simulation fidelity to the expected radiation fields predicted for the cold-mass regions of the SSC magnets, especially the corrector magnets. The authors present here results for some structural composite materials which were part of a larger irradiation-characterization of polymeric materials for SSC applications

  1. Hydrogen release from 800 MeV proton-irradiated tungsten

    Science.gov (United States)

    Oliver, B. M.; Venhaus, T. J.; Causey, R. A.; Garner, F. A.; Maloy, S. A.

    2002-12-01

    Tungsten irradiated in spallation neutron sources, such as those proposed for the accelerator production of tritium (APT) project, will contain large quantities of generated helium and hydrogen gas. Tungsten used in proposed fusion reactors will also be exposed to neutrons, and the generated protium will be accompanied by deuterium and tritium diffusing in from the plasma-facing surface. The release kinetics of these gases during various off-normal scenarios involving loss of coolant and after heat-induced rises in temperature are of particular interest for both applications. To determine the release kinetics of hydrogen from tungsten, tungsten rods irradiated with 800 MeV protons in the Los Alamos Neutron Science Center (LANSCE) to high exposures as part of the APT project have been examined. Hydrogen evolution from the tungsten has been measured using a dedicated mass-spectrometer system by subjecting the specimens to an essentially linear temperature ramp from ˜300 to ˜1500 K. Release profiles are compared with predictions obtained using the Tritium Migration Analysis Program (TMAP4). The measurements show that for high proton doses, the majority of the hydrogen is released gradually, starting at about 900 K and reaching a maximum at about 1400 K, where it drops fairly rapidly. Comparisons with TMAP show quite reasonable agreement using a trap energy of 1.4 eV and a trap density of ˜7%. There is a small additional release fraction occurring at ˜550 K, which is believed to be associated with low-energy trapping at or near the surface, and, therefore, was not included in the bulk TMAP model.

  2. Hydrogen release from 800 MeV proton-irradiated tungsten

    International Nuclear Information System (INIS)

    Oliver, B.M.; Venhaus, T.J.; Causey, R.A.; Garner, F.A.; Maloy, S.A.

    2002-01-01

    Tungsten irradiated in spallation neutron sources, such as those proposed for the accelerator production of tritium (APT) project, will contain large quantities of generated helium and hydrogen gas. Tungsten used in proposed fusion reactors will also be exposed to neutrons, and the generated protium will be accompanied by deuterium and tritium diffusing in from the plasma-facing surface. The release kinetics of these gases during various off-normal scenarios involving loss of coolant and after heat-induced rises in temperature are of particular interest for both applications. To determine the release kinetics of hydrogen from tungsten, tungsten rods irradiated with 800 MeV protons in the Los Alamos Neutron Science Center (LANSCE) to high exposures as part of the APT project have been examined. Hydrogen evolution from the tungsten has been measured using a dedicated mass-spectrometer system by subjecting the specimens to an essentially linear temperature ramp from ∼300 to ∼1500 K. Release profiles are compared with predictions obtained using the Tritium Migration Analysis Program (TMAP4). The measurements show that for high proton doses, the majority of the hydrogen is released gradually, starting at about 900 K and reaching a maximum at about 1400 K, where it drops fairly rapidly. Comparisons with TMAP show quite reasonable agreement using a trap energy of 1.4 eV and a trap density of ∼7%. There is a small additional release fraction occurring at ∼550 K, which is believed to be associated with low-energy trapping at or near the surface, and, therefore, was not included in the bulk TMAP model

  3. Hydrogen release from 800 MeV proton-irradiated tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, B.M. E-mail: brian.oliver@pnl.gov; Venhaus, T.J.; Causey, R.A.; Garner, F.A.; Maloy, S.A

    2002-12-01

    Tungsten irradiated in spallation neutron sources, such as those proposed for the accelerator production of tritium (APT) project, will contain large quantities of generated helium and hydrogen gas. Tungsten used in proposed fusion reactors will also be exposed to neutrons, and the generated protium will be accompanied by deuterium and tritium diffusing in from the plasma-facing surface. The release kinetics of these gases during various off-normal scenarios involving loss of coolant and after heat-induced rises in temperature are of particular interest for both applications. To determine the release kinetics of hydrogen from tungsten, tungsten rods irradiated with 800 MeV protons in the Los Alamos Neutron Science Center (LANSCE) to high exposures as part of the APT project have been examined. Hydrogen evolution from the tungsten has been measured using a dedicated mass-spectrometer system by subjecting the specimens to an essentially linear temperature ramp from {approx}300 to {approx}1500 K. Release profiles are compared with predictions obtained using the Tritium Migration Analysis Program (TMAP4). The measurements show that for high proton doses, the majority of the hydrogen is released gradually, starting at about 900 K and reaching a maximum at about 1400 K, where it drops fairly rapidly. Comparisons with TMAP show quite reasonable agreement using a trap energy of 1.4 eV and a trap density of {approx}7%. There is a small additional release fraction occurring at {approx}550 K, which is believed to be associated with low-energy trapping at or near the surface, and, therefore, was not included in the bulk TMAP model.

  4. Proton and gamma -Rays Irradiation-Induced Dark Current Random Telegraph Signal in a 0.18-mu{{m}} CMOS Image Sensor

    Science.gov (United States)

    Martin, E.; Nuns, T.; Virmontois, C.; David, J.-P.; Gilard, O.

    2013-08-01

    The dark current random telegraph signal (RTS) behavior has been studied in a five-transistor-per-pixel (5T) pinned photodiode 0.18-μm COTS active pixel sensor (APS). Several devices, irradiated using protons and gamma rays, have been studied in order to assess the ionizing and displacement damage effects. The influence of the proton energy, fluence, ionizing dose and applied bias during irradiation on the number of RTS pixels, the number of discrete levels, maximum transition amplitude, and mean switching time constants is investigated.

  5. Proposal for an irradiation facility at the TAEK SANAEM Proton Accelerator Facility

    Science.gov (United States)

    Demirköz, B.; Gencer, A.; Kiziloren, D.; Apsimon, R.

    2013-12-01

    Turkish Atomic Energy Authority's (TAEK's) Proton Accelerator Facility in Ankara, Turkey, has been inaugurated in May 2012 and is under the process of being certified for commercial radio-isotope production. Three of the four arms of the 30 MeV cyclotron are being used for radio-isotope production, while the fourth is foreseen for research and development of novel ideas and methods. The cyclotron can vary the beam current between 12 μA and 1.2 mA, sufficient for irradiation tests for semiconductor materials, detectors and devices. We propose to build an irradiation facility in the R&D room of this complex, open for use to the international detector development community.

  6. Characterization of proton irradiated 3D-DDTC pixel sensor prototypes fabricated at FBK

    CERN Document Server

    La Rosa, A; Cobal, M; Betta, G -F Dalla; Da Via, C; Darbo, G; Gallrapp, C; Gemme, C; Huegging, F; Janssen, J; Micelli, A; Pernegger, H; Povoli, M; Wermes, N; Zorzi, N

    2012-01-01

    In this paper we discuss results relevant to 3D Double-Side Double Type Column (3D-DDTC) pixel sensors fabricated at FBK (Trento, Italy) and oriented to the ATLAS upgrade. Some assemblies of these sensors featuring different columnar electrode configurations (2, 3, or 4 columns per pixel) and coupled to the ATLAS FEI3 read-out chip were irradiated up to large proton fluences and tested in laboratory with radioactive sources. In spite of the non optimized columnar electrode overlap, sensors exhibit reasonably good charge collection properties up to an irradiation fluence of 2 x 10**15 neq/cm2, while requiring bias voltages in the order of 100 V. Sensor operation is further investigated by means of TCAD simulations which can effectively explain the basic mechanisms responsible for charge loss after irradiation.

  7. Damage evaluation of proton irradiated titanium deuteride thin films to be used as neutron production targets

    Science.gov (United States)

    Suarez Anzorena, Manuel; Bertolo, Alma A.; Gagetti, Leonardo; Gaviola, Pedro A.; del Grosso, Mariela F.; Kreiner, Andrés J.

    2018-06-01

    Titanium deuteride thin films have been manufactured under different conditions specified by deuterium gas pressure, substrate temperature and time. The films were characterized by different techniques to evaluate the deuterium content and the homogeneity of such films. Samples with different concentrations of deuterium, including non deuterated samples, were irradiated with a 150 keV proton beam. Both deposits, pristine and irradiated, were characterized by optical profilometry and scanning electron microscopy.

  8. Assessing the effectiveness of pollutant removal by macrophytes in a floating wetland for wastewater treatment

    Science.gov (United States)

    Prajapati, Meera; van Bruggen, Johan J. A.; Dalu, Tatenda; Malla, Rabin

    2017-12-01

    The study aimed to evaluate the removal of pollutants by floating treatment wetlands (FTWs) using an edible floating plant, and emergent macrophytes. All experiments were performed under ambient conditions. Physico-chemical parameters were measured, along with microbiological analysis of biofilm within the roots, water column, and sludge and gravel zone. Nitrification and denitrification rates were high in the water zone of Azolla filiculoides, Lemna minor, Lactuca sativa, P. stratiotes, and Phragmites australis. Phosphate removal efficiencies were 23, 10, and 15% for the free-floating hydrophytes, emergent macrophytes, and control and edible plants, respectively. The microbial community was relatively more active in the root zone compared to other zones. Pistia stratiotes was found to be the efficient in ammonium (70%) and total nitrogen (59%) removal. Pistia stratiotes also showed the highest microbial activity of 1306 mg day-1, which was 62% of the total volume. Microbial activity was found in the water zone of all FTWs expect for P. australis. The use of P. stratiotes and the edible plant L. sativa could be a potential option to treat domestic wastewater due to relatively high nutrient and organic matter removal efficiency.

  9. Void formation in cold-worked type 316 stainless steel irradiated with 1-MeV protons

    International Nuclear Information System (INIS)

    Keefer, D.W.; Pard, A.G.

    1974-01-01

    Cold-worked Type 316 stainless steel was irradiated at 500 and 600 0 C with 1-MeV protons. The dependence of void formation on displacement damage, irradiation temperature, and microstructure was studied by transmission electron microscopy. Cold working delays the onset of swelling and reduces it, via a reduction in void size, at both irradiation temperatures. Inhomogeneity in the cold-worked microstructure leads to inhomogeneity in the disposition of voids. Swelling at 600 is greater than at 500 0 C; the voids are less numerous but larger at the higher temperature. No change in the cold-worked microstructure can be detected by transmission electron microscopy after 500 0 C irradiation to 23 displacements per atom. Irradiation to a comparable damage level at 600 0 C results in almost complete elimination of the cold-worked microstructure. Comparison of the results is made with data from reactor irradiation experiments

  10. Irradiation effects in beryllium exposed to high energy protons of the NuMI neutrino source

    Energy Technology Data Exchange (ETDEWEB)

    Kuksenko, V., E-mail: viacheslav.kuksenko@materials.ox.ac.uk [University of Oxford, Oxford (United Kingdom); Ammigan, K.; Hartsell, B. [Fermi National Accelerator Laboratory, Batavia (United States); Densham, C. [Rutherford Appleton Laboratory, Didcot (United Kingdom); Hurh, P. [Fermi National Accelerator Laboratory, Batavia (United States); Roberts, S. [University of Oxford, Oxford (United Kingdom)

    2017-07-15

    A beryllium primary vacuum-to-air beam ‘window’ of the 'Neutrinos at the Main Injector' (NuMI) beamline at Fermi National Accelerator Laboratory (Fermilab), Batavia, Illinois, USA, has been irradiated by 120 GeV protons over 7 years, with a maximum integrated fluence at the window centre of 2.06 10{sup 22} p/cm{sup 2} corresponding to a radiation damage level of 0.48 dpa. The proton beam is pulsed at 0.5 Hz leading to an instantaneous temperature rise of 40 °C per pulse. The window is cooled by natural convection and is estimated to operate at an average of around 50 °C. The microstructure of this irradiated material was investigated by SEM/EBSD and Atom Probe Tomography, and compared to that of unirradiated regions of the beam window and that of stock material of the same PF-60 grade. Microstructural investigations revealed a highly inhomogeneous distribution of impurity elements in both unirradiated and irradiated conditions. Impurities were mainly localised in precipitates, and as segregations at grain boundary and dislocation lines. Low levels of Fe, Cu, Ni, C and O were also found to be homogeneously distributed in the beryllium matrix. In the irradiated materials, up to 440 appm of Li, derived from transmutation of beryllium was homogeneously distributed in solution in the beryllium matrix.

  11. Studies on the preparation of thallium-201 by irradiating mercury with protons using extraction chromatography technique to separate thallium from mercury

    International Nuclear Information System (INIS)

    Fernandes, L.

    1990-01-01

    Radionuclide sup(201)Tl is used in Nuclear Medicine to identify myocardial ischemia or myocardial infarct. It is a cyclotron-produced radioisotope, obtained indirectly from the decay of sup(202)Pb or directly by irradiating mercury with deuterons or protons. The usual technique to prepare sup(201)Tl makes use of the nuclear reaction: sup(203)(p,3n) → sup(201)Tl, which requires proton energy of around 28 MeV. Due to the limited proton energy of IPEN'S CV-28 cyclotron, studies on the irradiating conditions of natural mercury oxide pellets and drops of natural mercury metal were made in the range of 19 - 24 MeV. At the end of the bombardment of a 6 MeV thickness target of natural mercury metal with 19 MeV protons around 10 MBq sup(201)Tl/μ A h was obtained. (author)

  12. Ultra-fast scintillation properties of β-Ga2O3 single crystals grown by Floating Zone method

    Science.gov (United States)

    He, Nuotian; Tang, Huili; Liu, Bo; Zhu, Zhichao; Li, Qiu; Guo, Chao; Gu, Mu; Xu, Jun; Liu, Jinliang; Xu, Mengxuan; Chen, Liang; Ouyang, Xiaoping

    2018-04-01

    In this investigation, β-Ga2O3 single crystals were grown by the Floating Zone method. At room temperature, the X-ray excited emission spectrum includes ultraviolet and blue emission bands. The scintillation light output is comparable to the commercial BGO scintillator. The scintillation decay times are composed of the dominant ultra-fast component of 0.368 ns and a small amount of slightly slow components of 8.2 and 182 ns. Such fast component is superior to most commercial inorganic scintillators. In contrast to most semiconductor crystals prepared by solution method such as ZnO, β-Ga2O3 single crystals can be grown by traditional melt-growth method. Thus we can easily obtain large bulk crystals and mass production.

  13. Treatment planning with protons for pediatric retinoblastoma, medulloblastoma, and pelvic sarcoma: How do protons compare with other conformal techniques?

    International Nuclear Information System (INIS)

    Lee, Catherine T.; Bilton, Stephen D.; Famiglietti, Robin M.; Riley, Beverly A.; Mahajan, Anita; Chang, Eric L.; Maor, Moshe H.; Woo, Shiao Y.; Cox, James D.; Smith, Alfred R.

    2005-01-01

    Purpose: To calculate treatment plans and compare the dose distributions and dose-volume histograms (DVHs) for photon three-dimensional conformal radiation therapy (3D-CRT), electron therapy, intensity-modulated radiation therapy (IMRT), and standard (nonintensity modulated) proton therapy in three pediatric disease sites. Methods and Materials: The tumor volumes from 8 patients (3 retinoblastomas, 2 medulloblastomas, and 3 pelvic sarcomas) were studied retrospectively to compare DVHs from proton therapy with 3D-CRT, electron therapy, and IMRT. In retinoblastoma, several planning techniques were analyzed: A single electron appositional beam was compared with a single 3D-CRT lateral beam, a 3D-CRT anterior beam paired with a lateral beam, IMRT, and protons. In medulloblastoma, three posterior fossa irradiation techniques were analyzed: 3D-CRT, IMRT, and protons. Craniospinal irradiation (which consisted of composite plans of both the posterior fossa and craniospinal components) was also evaluated, primarily comparing spinal irradiation using 3D-CRT electrons, 3D-CRT photons, and protons. Lastly, in pelvic sarcoma, 3D-CRT, IMRT, and proton plans were assessed. Results: In retinoblastoma, protons resulted in the best target coverage combined with the most orbital bone sparing (10% was the mean orbital bone volume irradiated at ≥5 Gy for protons vs. 25% for 3D-CRT electrons, 69% for IMRT, 41% for a single 3D lateral beam, 51% for a 3D anterolateral beam with a lens block, and 65% for a 3D anterolateral beam without a lens block). A single appositional electron field was the next best technique followed by other planning approaches. In medulloblastoma, for posterior fossa and craniospinal irradiation, protons resulted in the least dose to the cochlea (for only posterior fossa irradiation at ≥20 Gy, 34% was the mean cochlear volume irradiated for protons, 87% for IMRT, 89% for 3D-CRT) and hypothalamus-pituitary axis (for only posterior fossa irradiation at ≥10 Gy

  14. A review of dosimetric and toxicity modeling of proton versus photon craniospinal irradiation for pediatrics medulloblastoma.

    Science.gov (United States)

    Ho, Evangeline S Q; Barrett, Sarah A; Mullaney, Laura M

    2017-08-01

    Craniospinal irradiation (CSI) is the standard radiation therapy treatment for medulloblastoma. Conventional CSI photon therapy (Photon-CSI) delivers significant dose to surrounding normal tissue (NT). Research into pediatric CSI with proton therapy (Proton-CSI) has increased, with the aim of exploiting the potential to reduce NT dose and associated post-treatment complications. This review aims to compare treatment outcomes of pediatric medulloblastoma patients between Proton- and Photon-CSI treatments. A search and review of studies published between 1990 and 2016 comparing pediatric (2-18 years) medulloblastoma Proton- and Photon-CSI in three aspects - normal organ sparing and target coverage; normal organ dysfunction and second malignancy risks - was completed. Fifteen studies were selected for review and the results were directly compared. Proton-CSI reported improved out-of-field organ sparing while target coverage improvements were inconsistent. Normal organ dysfunction risks were predicted to be lower following Proton-CSI. Secondary malignancy risks (SMRs) were generally lower with Proton-CSI based on several different risk models. Proton-CSI conferred better treatment outcomes than Photon-CSI for pediatric medulloblastoma patients. This review serves to compare the current literature in the absence of long-term data from prospective studies.

  15. Damaging and protective bystander cross-talk between human lung cancer and normal cells after proton microbeam irradiation

    International Nuclear Information System (INIS)

    Desai, Sejal; Kobayashi, Alisa; Konishi, Teruaki; Oikawa, Masakazu; Pandey, Badri N.

    2014-01-01

    Graphical abstract: - Highlights: • Proton-microbeam irradiated A549 cells send damaging signals to bystander A549 cells. • Irradiated A549–A549 bystander response is through gap junctional communication. • Bystander WI38 cells exert protective signalling in irradiated A549 cells. • Rescue of irradiated A549 cells by WI38 cells is independent of gap junctions. - Abstract: Most of the studies of radiation-induced bystander effects (RIBE) have been focused on understanding the radiobiological changes observed in bystander cells in response to the signals from irradiated cells in a normal cell population with implications to radiation risk assessment. However, reports on RIBE with relevance to cancer radiotherapy especially investigating the bidirectional and criss-cross bystander communications between cancer and normal cells are limited. Hence, in present study employing co-culture approach, we have investigated the bystander cross-talk between lung cancer (A549) and normal (WI38) cells after proton-microbeam irradiation using γ-H2AX foci fluorescence as a measure of DNA double-strand breaks (DSBs). We observed that in A549–A549 co-cultures, irradiated A549 cells exert damaging effects in bystander A549 cells, which were found to be mediated through gap junctional intercellular communication (GJIC). However, in A549–WI38 co-cultures, irradiated A549 did not affect bystander WI38 cells. Rather, bystander WI38 cells induced inverse protective signalling (rescue effect) in irradiated A549 cells, which was independent of GJIC. On the other hand, in response to irradiated WI38 cells neither of the bystander cells (A549 or WI38) showed significant increase in γ-H2AX foci. The observed bystander signalling between tumour and normal cells may have potential implications in therapeutic outcome of cancer radiotherapy

  16. Damaging and protective bystander cross-talk between human lung cancer and normal cells after proton microbeam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Sejal [Radiation Signalling and Cancer Biology Section, Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kobayashi, Alisa; Konishi, Teruaki; Oikawa, Masakazu [Radiation System and Engineering Section, Department of Technical Support and Development, Research, Development and Support Center, National Institute of Radiological Sciences, Chiba 263-8555 (Japan); Pandey, Badri N., E-mail: badrinarain@yahoo.co.in [Radiation Signalling and Cancer Biology Section, Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2014-05-15

    Graphical abstract: - Highlights: • Proton-microbeam irradiated A549 cells send damaging signals to bystander A549 cells. • Irradiated A549–A549 bystander response is through gap junctional communication. • Bystander WI38 cells exert protective signalling in irradiated A549 cells. • Rescue of irradiated A549 cells by WI38 cells is independent of gap junctions. - Abstract: Most of the studies of radiation-induced bystander effects (RIBE) have been focused on understanding the radiobiological changes observed in bystander cells in response to the signals from irradiated cells in a normal cell population with implications to radiation risk assessment. However, reports on RIBE with relevance to cancer radiotherapy especially investigating the bidirectional and criss-cross bystander communications between cancer and normal cells are limited. Hence, in present study employing co-culture approach, we have investigated the bystander cross-talk between lung cancer (A549) and normal (WI38) cells after proton-microbeam irradiation using γ-H2AX foci fluorescence as a measure of DNA double-strand breaks (DSBs). We observed that in A549–A549 co-cultures, irradiated A549 cells exert damaging effects in bystander A549 cells, which were found to be mediated through gap junctional intercellular communication (GJIC). However, in A549–WI38 co-cultures, irradiated A549 did not affect bystander WI38 cells. Rather, bystander WI38 cells induced inverse protective signalling (rescue effect) in irradiated A549 cells, which was independent of GJIC. On the other hand, in response to irradiated WI38 cells neither of the bystander cells (A549 or WI38) showed significant increase in γ-H2AX foci. The observed bystander signalling between tumour and normal cells may have potential implications in therapeutic outcome of cancer radiotherapy.

  17. Development of disease animal models using proton beam

    International Nuclear Information System (INIS)

    Nam, K. H.; Kim, E. K.; Kim, H. R.; Seo, Y. W.

    2010-03-01

    To identify proper proton beam dose for mutant mouse development, total 7 times of proton beam were performed. There are too low incidence of mutation in pup mouse which were derived embryos radiated by 1Gy proton beam. Some mutation could be identified in pup mice which were derived embryos radiated by 1.5-2.5Gy proton beam. Mouse embryos irradiated with 1-10Gy of proton beam were inhibited in their in vitro development to 2 cell stage. There was no pups born from embryos which were irradiated with proton beam over 3 Gy. Early mouse development were greatly inhibited by proton beam irradiation of over 10Gy when cultured in vitro. In conclusion, it is efficient to irradiate mouse embryo with 1.5-2.5Gy of proton beam for development of mutant mice

  18. Cross sections from 800 MeV proton irradiation of terbium

    Energy Technology Data Exchange (ETDEWEB)

    Engle, J.W., E-mail: jwengle@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Mashnik, S.G.; Bach, H.; Couture, A.; Jackman, K.; Gritzo, R.; Ballard, B.D.; Fassbender, M.; Smith, D.M.; Bitteker, L.J.; Ullmann, J.L.; Gulley, M.S.; Pillai, C.; John, K.D.; Birnbaum, E.R. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Nortier, F.M., E-mail: meiring@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2012-11-02

    Terbium foils were irradiated with 800 MeV protons to ascertain the potential for production of lanthanide isotopes of interest in medical, astrophysical, and basic science research and to contribute to nuclear data repositories. Isotopes produced in the foil were quantified by gamma spectroscopy. Cross sections for 35 isotopes produced in the irradiation are reported and compared with predictions by the MCNP6 transport code using the CEM03.03, Bertini and INCL + ABLA event generators. Our results indicate the need to accurately consider fission and fragmentation of relatively light target nuclei like terbium in the modeling of nuclear reactions at 800 MeV. The predictive power of the code was found to be different for each event generator tested but was satisfactory for most of the product yields in the mass region where spallation reactions dominate. However, none of the event generators' results are in complete agreement with measured data.

  19. Diffusion length variation in 0.5- and 3-MeV-proton-irradiated, heteroepitaxial indium phosphide solar cells

    Science.gov (United States)

    Jain, Raj K.; Weinberg, Irving; Flood, Dennis J.

    1993-01-01

    Indium phosphide (InP) solar cells are more radiation resistant than gallium arsenide (GaAs) and silicon (Si) solar cells, and their growth by heteroepitaxy offers additional advantages leading to the development of light weight, mechanically strong, and cost-effective cells. Changes in heteroepitaxial InP cell efficiency under 0.5- and 3-MeV proton irradiations have been explained by the variation in the minority-carrier diffusion length. The base diffusion length versus proton fluence was calculated by simulating the cell performance. The diffusion length damage coefficient, K(sub L), was also plotted as a function of proton fluence.

  20. Majority- and minority-carrier deep level traps in proton-irradiated n+/p-InGaP space solar cells

    International Nuclear Information System (INIS)

    Dharmarasu, Nethaji; Yamaguchi, Masafumi; Bourgoin, Jacques C.; Takamoto, Tatsuya; Ohshima, Takeshi; Itoh, Hisayoshi; Imaizumi, Mitsuru; Matsuda, Sumio

    2002-01-01

    We report the properties of observed defects in n + /p-InGaP solar cells created by irradiation of protons of different energies. Three majority (hole) and a minority-carrier traps, labeled respectively as HP1 (E v +0.90±0.05 eV), HP2 (E v +0.73±0.05 eV), H2 (E v +0.55 eV), and EP1 (E c -0.54 eV), were identified using deep level transient spectroscopy. All majority-carrier traps were found to act as recombination centers. While the H2 trap present in the proton-irradiated p-InGaP was found to anneal out by minority-carrier injection, the other traps were not

  1. Characterization of proton irradiated 3D-DDTC pixel sensor prototypes fabricated at FBK

    Energy Technology Data Exchange (ETDEWEB)

    La Rosa, A., E-mail: alessandro.larosa@cern.ch [CERN, Geneva 23, CH-1211 (Switzerland); Boscardin, M. [Fondazione Bruno Kessler, FBK-CMM, Via Sommarive 18, I-38123 Trento (Italy); Cobal, M. [Universita degli Studi di Udine and INFN Trieste, Gruppo Collegato di Udine, Via delle Scienze 208, I-33100 Udine (Italy); Dalla Betta, G.-F. [DISI, Universita degli Studi di Trento and INFN Padova, Gruppo Collegato d Trento, Via Sommarive 14, I-38123 Trento (Italy); Da Via, C. [School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Darbo, G. [INFN Sezione di Genova, Via Dodecaneso 33, I-14146 Genova (Italy); Gallrapp, C. [CERN, Geneva 23, CH-1211 (Switzerland); Gemme, C. [INFN Sezione di Genova, Via Dodecaneso 33, I-14146 Genova (Italy); Huegging, F.; Janssen, J. [Physikalisches Institut, Universitaet Bonn, Nussallee 12, D-53115 Bonn (Germany); Micelli, A. [Universita degli Studi di Udine and INFN Trieste, Gruppo Collegato di Udine, Via delle Scienze 208, I-33100 Udine (Italy); Pernegger, H. [CERN, Geneva 23, CH-1211 (Switzerland); Povoli, M. [DISI, Universita degli Studi di Trento and INFN Padova, Gruppo Collegato d Trento, Via Sommarive 14, I-38123 Trento (Italy); Wermes, N. [Physikalisches Institut, Universitaet Bonn, Nussallee 12, D-53115 Bonn (Germany); Zorzi, N. [Fondazione Bruno Kessler, FBK-CMM, Via Sommarive 18, I-38123 Trento (Italy)

    2012-07-21

    In this paper we discuss results relevant to 3D Double-Side Double Type Column (3D-DDTC) pixel sensors fabricated at FBK (Trento, Italy) and oriented to the ATLAS upgrade. Some assemblies of these sensors featuring different columnar electrode configurations (2, 3, or 4 columns per pixel) and coupled to the ATLAS FEI3 read-out chip were irradiated up to large proton fluences and tested in laboratory with radioactive sources. In spite of the non-optimized columnar electrode overlap, sensors exhibit reasonably good charge collection properties up to an irradiation fluence of 2 Multiplication-Sign 10{sup 15}n{sub eq}cm{sup -2}, while requiring bias voltages in the order of 100 V. Sensor operation is further investigated by means of TCAD simulations which can effectively explain the basic mechanisms responsible for charge loss after irradiation.

  2. Analysis of proton irradiation products in simulated interstellar dusts by mass spectrometry

    International Nuclear Information System (INIS)

    Kasamatsu, Takashi; Kaneko, Takeo; Tsuchiya, Masahiko; Kobayashi, Kensei

    1996-01-01

    It is known that various kinds of organic compounds exist in space. In order to study the possibility of the formation of organic compounds in comets or their precursory bodies (interstellar dust grains), ice mixtures of carbon monoxide (or methane), ammonia and water made in a cryostat at 10 K ('simulated cometary ices') were irradiated with high energy protons. Irradiated ice products were warmed up to room temperature, while sublimed gases were analyzed with a quadrupole mass spectrometer. Some hydrocarbons and alcohols were detected. 'Amino acid precursors' (compounds yielding amino acids after hydrolysis) were detected in non-volatile products remaining on the substrate at room temperature. These results suggest the possible formation of organic compounds in interstellar dust grains by cosmic radiation. (author)

  3. A Comparison of Molecular and Histopathological Changes in Mouse Intestinal Tissue Following Whole-Body Proton- or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Mangala, Lingegowda; Zhang, Ye; Hamilton, Stanley; Wu, Honglu

    2010-01-01

    There are many consequences following exposure to the space radiation environment which can adversely affect the health of a crew member. Acute radiation syndrome (ARS) involving nausea and vomiting, damage to radio-sensitive tissue such as the blood forming organs and gastrointestinal tract, and cancer are some of these negative effects. The space radiation environment is ample with protons and contains gamma rays as well. Little knowledge exists to this point, however, regarding the effects of protons on mammalian systems; conversely several studies have been performed observing the effects of gamma rays on different animal models. For the research presented here, we wish to compare our previous work looking at whole-body exposure to protons using a mouse model to our studies of mice experiencing whole-body exposure to gamma rays as part of the radio-adaptive response. Radio-adaptation is a well-documented phenomenon in which cells exposed to a priming low dose of radiation prior to a higher dose display a reduction in endpoints like chromosomal aberrations, cell death, micronucleus formation, and more when compared to their counterparts receiving high dose-irradiation only. Our group has recently completed a radio-adaptive experiment with C57BL/6 mice. For both this study and the preceding proton research, the gastrointestinal tract of each animal was dissected four hours post-irradiation and the isolated small intestinal tissue was fixed in formalin for histopathological examination or snap-frozen in liquid nitrogen for RNA isolation. Histopathologic observation of the tissue using standard H&E staining methods to screen for morphologic changes showed an increase in apoptotic lesions for even the lowest doses of 0.1 Gy of protons and 0.05 Gy of gamma rays, and the percentage of apoptotic cells increased with increasing dose. A smaller percentage of crypts showed 3 or more apoptotic lesions in animals that received 6 Gy of gamma-irradiation compared to mice

  4. Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation

    International Nuclear Information System (INIS)

    Priegnitz, M; Helmbrecht, S; Fiedler, F; Janssens, G; Smeets, J; Vander Stappen, F; Perali, I; Sterpin, E

    2015-01-01

    Proton and ion beam therapies become increasingly relevant in radiation therapy. To fully exploit the potential of this irradiation technique and to achieve maximum target volume conformality, the verification of particle ranges is highly desirable. Many research activities focus on the measurement of the spatial distributions of prompt gamma rays emitted during irradiation. A passively collimating knife-edge slit camera is a promising option to perform such measurements. In former publications, the feasibility of accurate detection of proton range shifts in homogeneous targets could be shown with such a camera. We present slit camera measurements of prompt gamma depth profiles in inhomogeneous targets. From real treatment plans and their underlying CTs, representative beam paths are selected and assembled as one-dimensional inhomogeneous targets built from tissue equivalent materials. These phantoms have been irradiated with monoenergetic proton pencil beams. The accuracy of range deviation estimation as well as the detectability of range shifts is investigated in different scenarios. In most cases, range deviations can be detected within less than 2 mm. In close vicinity to low-density regions, range detection is challenging. In particular, a minimum beam penetration depth of 7 mm beyond a cavity is required for reliable detection of a cavity filling with the present setup. Dedicated data post-processing methods may be capable of overcoming this limitation. (paper)

  5. Proton irradiation effects in oxide-confined vertical cavity surface emitting laser (VCSEL) diodes

    International Nuclear Information System (INIS)

    Barnes, C.E.; Swift, G.M.; Guertin, S.; Schwank, J.R.; Armendariz, M.G.; Hash, G.L.; Choquette, K.D.

    1999-01-01

    Vertical cavity surface emitting laser (VCSEL) diodes are employed as the emitter portion of opto-couplers that are used in space applications. Proton irradiation studies on VCSELs were performed at the Indiana University cyclotron facility. The beam energy was set at 192 MeV, the beam current was 200 nA that is equivalent to a flux of approximately 1*10 11 protons/cm 2 .s. We conclude that the oxide confined VCSELs examined in this study show more than sufficient radiation hardness for nearly all space applications. The observed proton-induced decreases in light output and the corresponding increases in laser threshold current can be explained in terms of proton-induced displacement damage which introduces non-radiative recombination centers in the active region of the lasers and causes a decrease in laser efficiency. These radiation effects accentuate the detrimental thermal effects observed at high currents. We also note that forward bias annealing is effective in these devices in producing at least partial recovery of the light output, and that this may be a viable hardness assurance technique during a flight mission. (A.C.)

  6. Photocarrier radiometry for predicting the degradation of electrical parameters of monocrystalline silicon (c-Si) solar cell irradiated by 100 KeV proton beams

    International Nuclear Information System (INIS)

    Song, P.; Liu, J.Y.; Yuan, H.M.; Oliullah, Md.; Wang, F.; Wang, Y.

    2016-01-01

    In this study, the monocrystalline silicon (c-Si) solar cell irradiated by 100 KeV proton beams at various fluences is investigated. A one-dimensional two-layer carrier density wave model has been developed to estimate the minority carrier lifetime of n-region and p-region of the non-irradiated c-Si solar cell by best fitting with the experimental photocarrier radiometry (PCR) signal (the amplitude and the phase). Furthermore, the lifetime is used to determine the initial defect density of the quasi-neutral region (QNR) of the solar cell to predict its I–V characteristics. The theoretically predicted short-circuit current density (J_s_c), and open-circuit voltage (V_o_c) of the non-irradiated samples are in good agreement with experiment. Then a three-region defect distribution model for the c-Si solar cell irradiated by proton beams is carried out to describe the defect density distribution according to Monte Carlo simulation results and the initial defect density of the non-irradiated sample. Finally, we find that the electrical measurements of J_s_c and V_o_c of the solar cells irradiated at different fluences using 100 KeV proton beams are consistent with the PCR predicting results.

  7. Photocarrier radiometry for predicting the degradation of electrical parameters of monocrystalline silicon (c-Si) solar cell irradiated by 100 KeV proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Song, P. [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); Liu, J.Y., E-mail: ljywlj@hit.edu.cn [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); State Key Laboratory of Robotics and System (HIT), Harbin 150001 (China); Yuan, H.M.; Oliullah, Md.; Wang, F. [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); Wang, Y., E-mail: songpengkevin@126.com [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China); State Key Laboratory of Robotics and System (HIT), Harbin 150001 (China)

    2016-09-15

    In this study, the monocrystalline silicon (c-Si) solar cell irradiated by 100 KeV proton beams at various fluences is investigated. A one-dimensional two-layer carrier density wave model has been developed to estimate the minority carrier lifetime of n-region and p-region of the non-irradiated c-Si solar cell by best fitting with the experimental photocarrier radiometry (PCR) signal (the amplitude and the phase). Furthermore, the lifetime is used to determine the initial defect density of the quasi-neutral region (QNR) of the solar cell to predict its I–V characteristics. The theoretically predicted short-circuit current density (J{sub sc}), and open-circuit voltage (V{sub oc}) of the non-irradiated samples are in good agreement with experiment. Then a three-region defect distribution model for the c-Si solar cell irradiated by proton beams is carried out to describe the defect density distribution according to Monte Carlo simulation results and the initial defect density of the non-irradiated sample. Finally, we find that the electrical measurements of J{sub sc} and V{sub oc} of the solar cells irradiated at different fluences using 100 KeV proton beams are consistent with the PCR predicting results.

  8. Late cataractogenesis in rhesus monkeys irradiated with protons and radiogenic cataract in other species

    International Nuclear Information System (INIS)

    Lett, J.T.; Lee, A.C.; Cox, A.B.

    1991-01-01

    Rhesus monkeys (Macaca mulatta) which were irradiated at ca. 2 years of age with acute doses (less than or equal to 5 Gy) of protons (32-2300 MeV) are exhibiting the late progressive phase of radiation cataractogenesis 20-24 years after exposure, the period during which we have been monitoring the sequelae of irradiation of the lens. The median life span of the primate is approximately 24 years. Analogous late ocular changes also occur in a similar period of the lifetimes of New Zealand White (NZW) rabbits (Oryctolagus cuniculus) exposed at 8-10 weeks of age to 460-MeV 56 Fe ions. In this experiment, which has been in progress for ca. 6 years, we are following the development of radiation-induced lenticular opacification (cataractogenic profiles) throughout the life span. The median life span of the lagomorph is 5-7 years. Cataractogenic profiles for NZW rabbits irradiated with 20 Ne and 40 Ar ions and 60 Co gamma photons were obtained previously. Reference is also made to measurements of the cataractogenic profiles of a short-lived rodent, the Fischer 344 rat (Rattus norvegicus) during the first year after exposure at 8-10 weeks of age to spread-Bragg-peak protons of 55 MeV nominal energy. The median life span of the rodent is reported to be 2-3 years

  9. Local mechanical stress relaxation of Gunn diodes irradiated by protons

    International Nuclear Information System (INIS)

    Gradoboev, A V; Tesleva, E P

    2017-01-01

    The aim of the work is studying the impact of Gunn diodes thermocompression bonding conditions upon their resistance to being radiated with protons of various energies. It was established that the tough conditions of Gunn diodes thermocompression bonding results in local mechanic stresses introduced into the active layer of the device, reduction of electron mobility because of the faults introduction and, subsequently, to reduction of operating current, power of UHF generation, percentage of qualitative units production and general reduction of production efficiency of the devices with required characteristics. Irradiation of Gunn diodes produced under the tough conditions of thermocompression bonding with protons which energy is (40–60) MeV with an absorbed dose of (1–6)·10 2 Gy does not practically reduce the radiation resistance of Gunn diodes produced with application of the given technique. This technique can be recommended for all semiconductor devices on the base of GaAs, which parameters depend significantly upon the mobility of the electrons, to increase the efficiency of production. (paper)

  10. Capability demonstration of simultaneous proton beam irradiation during exposure to molten lead–bismuth eutectic for HT9 steel

    International Nuclear Information System (INIS)

    Qvist, Staffan; Bolind, Alan Michael; Hosemann, Peter; Wang, Yongqiang; Tesmer, Joseph; De Caro, Magdalena Serrano; Bourke, Mark

    2013-01-01

    We report the design and assembly of a corrosion station to enable simultaneous proton irradiation of a metallic surface that was also in contact with molten lead–bismuth eutectic (LBE). The capability has been established at the ion beam materials laboratory at Los Alamos National Laboratory (LANL). The engineering design focused on temperature and oxygen content control in the LBE, as well as the ability to achieve doses significantly in excess of 1 dpa in the contact region over the irradiation campaigns. In the preliminary demonstration of capability reported here, a sample made of HT9 steel was placed in contact with LBE at 450 °C and irradiated for 58 h at an average proton beam current of 0.3 μA/mm 2 . SRIM [1] calculations indicate that the nominal surface dose ranged from approximately 3–22 dpa. This paper outlines the experimental setup and design constraints. Characterization of the sample will be reported in a subsequent paper.

  11. Capability demonstration of simultaneous proton beam irradiation during exposure to molten lead–bismuth eutectic for HT9 steel

    Energy Technology Data Exchange (ETDEWEB)

    Qvist, Staffan, E-mail: staffan@berkeley.edu [University of California, Berkeley (United States); Bolind, Alan Michael [University of California, Berkeley (United States); Japan Atomic Energy Agency (Japan); Hosemann, Peter [University of California, Berkeley (United States); Wang, Yongqiang; Tesmer, Joseph; De Caro, Magdalena Serrano; Bourke, Mark [Los Alamos National Laboratory (United States)

    2013-01-11

    We report the design and assembly of a corrosion station to enable simultaneous proton irradiation of a metallic surface that was also in contact with molten lead–bismuth eutectic (LBE). The capability has been established at the ion beam materials laboratory at Los Alamos National Laboratory (LANL). The engineering design focused on temperature and oxygen content control in the LBE, as well as the ability to achieve doses significantly in excess of 1 dpa in the contact region over the irradiation campaigns. In the preliminary demonstration of capability reported here, a sample made of HT9 steel was placed in contact with LBE at 450 °C and irradiated for 58 h at an average proton beam current of 0.3 μA/mm{sup 2}. SRIM [1] calculations indicate that the nominal surface dose ranged from approximately 3–22 dpa. This paper outlines the experimental setup and design constraints. Characterization of the sample will be reported in a subsequent paper.

  12. Investigation of the mid-infrared emission of a floating water bridge

    International Nuclear Information System (INIS)

    Fuchs, Elmar C; Paulitsch-Fuchs, Astrid H; Agostinho, Luewton L F; Wexler, Adam D; Cherukupally, Anvesh; Woisetschläger, Jakob; Freund, Friedemann T

    2012-01-01

    We report on the infrared emission of aqueous bridges under the application of high dc voltage (‘floating water bridge’) over the range between 400 and 2500 cm -1 (4.0-10.3 µm). Comparison with bulk water of the same temperature reveals an additional broad peak at ∼2200 cm -1 as well as water vapour emission lines. Two complementary explanations are presented for the broad peak: first, a cooperative proton transfer comprising an orientational motion along the direction of conduction is suggested. Second, the electrolysis-less current flow is explained by a proton/defect-proton band mechanism, which is in line with the cooperative proton transfer. The water vapour emissions occur due to collision ionization of space charges with micro- and nano-droplets which are electrosprayed from the liquid/gas interface.

  13. Investigation of the mid-infrared emission of a floating water bridge

    Science.gov (United States)

    Fuchs, Elmar C.; Cherukupally, Anvesh; Paulitsch-Fuchs, Astrid H.; Agostinho, Luewton L. F.; Wexler, Adam D.; Woisetschläger, Jakob; Freund, Friedemann T.

    2012-11-01

    We report on the infrared emission of aqueous bridges under the application of high dc voltage (‘floating water bridge’) over the range between 400 and 2500 cm-1 (4.0-10.3 µm). Comparison with bulk water of the same temperature reveals an additional broad peak at ˜2200 cm-1 as well as water vapour emission lines. Two complementary explanations are presented for the broad peak: first, a cooperative proton transfer comprising an orientational motion along the direction of conduction is suggested. Second, the electrolysis-less current flow is explained by a proton/defect-proton band mechanism, which is in line with the cooperative proton transfer. The water vapour emissions occur due to collision ionization of space charges with micro- and nano-droplets which are electrosprayed from the liquid/gas interface.

  14. Gene Expression Changes in Mouse Intestinal Tissue Following Whole-Body Proton or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Zhang, Ye; Mangala, Lingegowda; Nie, Ying; Gridley, Daila; Hamilton, Stanley R.; Seidel, Derek V.; Wu, Honglu

    2014-01-01

    Crew members face potential consequences following exposure to the space radiation environment including acute radiation syndrome and cancer. The space radiation environment is ample with protons, and numerous studies have been devoted to the understanding of the health consequences of proton exposures. In this project, C57BL/6 mice underwent whole-body exposure to 250 MeV of protons at doses of 0, 0.1, 0.5, 2 and 6 Gy and the gastrointestinal (GI) tract of each animal was dissected four hours post-irradiation. Standard H&E staining methods to screen for morphologic changes in the tissue showed an increase in apoptotic lesions for even the lowest dose of 0.1 Gy, and the percentage of apoptotic cells increased with increasing dose. Results of gene expression changes showed consistent up- or down- regulation, up to 10 fold, of a number of genes across exposure doses that may play a role in proton-induced oxidative stress including Gpx2. A separate study in C57BL/6 mice using the same four hour time point but whole-body gamma-irradiation showed damage to the small intestine with lesions appearing at the smallest dose of 0.05 Gy and increasing with increasing absorbed dose. Expressions of genes associated with oxidative stress processes were analyzed at four hours and twenty-four hours after exposure to gamma rays. We saw a much greater number of genes with significant up- or down-regulation twenty-four hours post-exposure as compared to the four hour time point. At both four hours and twenty-four hours post-exposure, Duox1 and Mpo underwent up-regulation for the highest dose of 6 Gy. Both protons and gamma rays lead to significant variation in gene expressions and these changes may provide insight into the mechanism of injury seen in the GI tract following radiation exposure. We have also completed experiments using a BALB/c mouse model undergoing whole-body exposure to protons. Doses of 0, 0.1, 1 and 2 Gy were used and results will be compared to the work mentioned

  15. Pressure control of a proton beam-irradiated water target through an internal flow channel-induced thermosyphon.

    Science.gov (United States)

    Hong, Bong Hwan; Jung, In Su

    2017-07-01

    A water target was designed to enhance cooling efficiency using a thermosyphon, which is a system that uses natural convection to induce heat exchange. Two water targets were fabricated: a square target without any flow channel and a target with a flow channel design to induce a thermosyphon mechanism. These two targets had the same internal volume of 8 ml. First, visualization experiments were performed to observe the internal flow by natural convection. Subsequently, an experiment was conducted to compare the cooling performance of both water targets by measuring the temperature and pressure. A 30-MeV proton beam with a beam current of 20 μA was used to irradiate both targets. Consequently, the target with an internal flow channel had a lower mean temperature and a 50% pressure drop compared to the target without a flow channel during proton beam irradiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Spatial distribution of moderated neutrons along a Pb target irradiated by high-energy protons

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Manolopoulou, M.; Stoulos, S.; Brandt, R.; Westmeier, W.; Kulakov, B.A.; Krivopustov, M.I.; Sosnin, A.N.; Debeauvais, M.; Adloff, J.C.; Zamani Valasiadou, M.

    2006-01-01

    High-energy protons in the range of 0.5-7.4 GeV have irradiated an extended Pb target covered with a paraffin moderator. The moderator was used in order to shift the hard Pb spallation neutron spectrum to lower energies and to increase the transmutation efficiency via (n,γ) reactions. Neutron distributions along and inside the paraffin moderator were measured. An analysis of the experimental results was performed based on particle production by high-energy interactions with heavy targets and neutron spectrum shifting by the paraffin. Conclusions about the spallation neutron production in the target and moderation through the paraffin are presented. The study of the total neutron fluence on the moderator surface as a function of the proton beam energy shows that neutron cost is improved up to 1 GeV. For higher proton beam energies it remains constant with a tendency to decline

  17. Water flow and solute transport in floating fen root mats

    Science.gov (United States)

    Stofberg, Sija F.; EATM van der Zee, Sjoerd

    2015-04-01

    Floating fens are valuable wetlands, found in North-Western Europe, that are formed by floating root mats when old turf ponds are colonized by plants. These terrestrialization ecosystems are known for their biodiversity and the presence of rare plant species, and the root mats reveal different vegetation zones at a small scale. The vegetation zones are a result of strong gradients in abiotic conditions, including groundwater dynamics, nutrients and pH. To prevent irreversible drought effects such as land subsidence and mineralization of peat, water management involves import of water from elsewhere to maintain constant surface water levels. Imported water may have elevated levels of salinity during dry summers, and salt exposure may threaten the vegetation. To assess the risk of exposure of the rare plant species to salinity, the hydrology of such root mats must be understood. Physical properties of root mats have scarcely been investigated. We have measured soil characteristics, hydraulic conductivity, vertical root mat movement and groundwater dynamics in a floating root mat in the nature reserve Nieuwkoopse Plassen, in the Netherlands. The root mat mostly consists of roots and organic material, in which the soil has a high saturated water content, and strongly varies in its stage of decomposition. We have found a distinct negative correlation between degree of decomposition and hydraulic conductivity, similar to observations for bogs in the literature. Our results show that the relatively young, thin edge of the root mat that colonizes the surface water has a high hydraulic conductivity and floats in the surface water, resulting in very small groundwater fluctuations within the root mat. The older part of the root mat, that is connected to the deeper peat layers is hydrologically more isolated and the material has a lower conductivity. Here, the groundwater fluctuates strongly with atmospheric forcing. The zones of hydraulic properties and vegetation, appear to

  18. Extraction of carrier-free 103Pd from thin rhodium wire irradiated with a proton beam in U-150 cyclotron

    International Nuclear Information System (INIS)

    Yuldashev, B.S.; Khudajbergenov, U.; Gulamov, I.R.; Mirzarva, M.A.; Rylov, A.A.

    2003-01-01

    A procedure for preparation of 103 Pd isotope of 99.9 % purity from a thin rhodium wire irradiated by 21 MeV proton beam in a cyclotron was developed. The desired product was prepared by electrolytic dissolution of the irradiated target in 6 M HCl with subsequent extraction of 103 Pd isotope without carrier by dimethylglyoxime in chloroform [ru

  19. Fabrication of optical devices in poly(dimethylsiloxane) by proton microbeam

    International Nuclear Information System (INIS)

    Huszank, R.; Szilasi, S.Z.; Rajta, I.; Csik, A.

    2009-01-01

    Complete text of publication follows. Optical diffraction grating and micro Fresnel zone plate type structures were fabricated in relatively thin poly(dimethylsiloxane) (PDMS) layers using proton beam writing technique and the performance of these optical devices was tested. Micro-optics is a key technology in many fields of common applications like, for example, data communication, lighting technology, industrial automation, display technology, sensing applications and data storage. It enables new functionalities and applications previously inaccessible and improves performance of the already available products with reduced cost, volume and weight. There are a few different fabrication techniques to produce refractive or diffractive micro-optical devices such as X-ray lithography, UV-lithography, e-beam lithography, laser writing, plasma etching, proton beam writing. In general, three different kinds of materials are used for micro-optics, such as glass, polymers and crystal. PDMS is a commonly used silicon-based organic polymer, optically clear, generally considered to be inert, non-toxic and biocompatible and it has been used as a resist material for direct write techniques only in very few cases. In this work, PDMS was used as a resist material; the structures were irradiated directly into the polymer. We were looking for a biocompatible, micropatternable polymer in which the chemical structure changes significantly due to proton beam exposure making the polymer capable of proton beam writing. We demonstrated that the change in the structure of the polymer is so significant that there is no need to perform any development processes. The proton irradiation causes refractive index change in the polymer, so diffraction gratings and other optical devices like Fresnel zone plates can be fabricated in this way. The observed high order diffraction patterns prove the high quality of the created optical devices [1]. This technique may be a useful tool for designing

  20. Recovery of Ra-223 from natural thorium irradiated by protons

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, Aleksandr N.; Ostapenko, Valentina S. [Lomonosov Moscow State Univ. (Russian Federation); Russian Academy of Sciences, Moscow-Troitsk (Russian Federation). Inst. for Nuclear Research; Lapshina, Elena V.; Ermolaev, Stanislav V.; Zhuikov, Boris L. [Russian Academy of Sciences, Moscow-Troitsk (Russian Federation). Inst. for Nuclear Research; Danilov, Sergey S. [Lomonosov Moscow State Univ. (Russian Federation); Kalmykov, Stepan N. [Lomonosov Moscow State Univ. (Russian Federation); National Research Center ' Kurchatov Institute' (NRC ' Kurchatov Institute' ), Moscow (Russian Federation)

    2016-11-01

    Irradiation of natural thorium with medium-energy protons is considered to be a prospective approach to large-scale production of {sup 225}Ac and {sup 223}Ra. In addition to the earlier-developed method of {sup 225}Ac isolation, the present work focuses on the simultaneous recovery of {sup 223}Ra from the same thorium target. Radiochemical procedure is based on liquid-liquid extraction, cation exchange and extraction chromatography. The procedure provides separation of radium from spallation and fission products generated in the thorium target. High chemical yield (85-90%) and radionuclide purity of {sup 223}Ra (> 99.8% except {sup 224}Ra and {sup 225}Ra isotopes) have been achieved.

  1. Postirradiation tensile properties of Mo and Mo alloys irradiated with 600 MeV protons

    International Nuclear Information System (INIS)

    Mueller, G.V.; Gavillet, D.; Victoria, M.; Martin, J.L.

    1994-01-01

    Tensile specimens of pure Mo and Mo-5 Re, Mo-41 Re and TZM alloys have been irradiated with 600 MeV protons in the PIREX facility at 300 and 660 K to 0.5 dpa. Results of the postirradiation tensile testing show a strong radiation hardening and a severe loss of ductility for all the materials tested at room temperature. ((orig.))

  2. Hydrogen- and helium-implanted silicon: Low-temperature positron-lifetime studies

    DEFF Research Database (Denmark)

    Mäkinen, S.; Rajainmäki, H.; Linderoth, Søren

    1991-01-01

    High-purity single-crystal samples of float-zoned Si have been implanted with 6.95-MeV protons and with 25-MeV 3He2 ions at 15 K, and the positron-lifetime technique has been used to identify the defects created in the samples, and to study the effects of H and He on the annealing of point defects...... in Si. The results have been compared with those of proton-irradiated Si. A 100–300-K annealing stage was clearly observed in hydrogen (H+) -implanted Si, and this stage was almost identical to that in the p-irradiated Si. The final annealing state of the H+-implanted Si started at about 400 K......, and it is connected to annealing out of negatively charged divacancy-oxygen pairs. This stage was clearly longer than that for the p-irradiated Si, probably due to the breakup of Si-H bonds at about 550 K. The 100-K annealing stage was not seen with the He-implanted samples. This has been explained by assuming...

  3. Effects of low temperature periodic annealing on the deep-level defects in 200 keV proton irradiated AlGaAs-GaAs solar cells

    Science.gov (United States)

    Li, S. S.; Chiu, T. T.; Loo, R. Y.

    1981-01-01

    The GaAs solar cell has shown good potential for space applications. However, degradation in performance occurred when the cells were irradiated by high energy electrons and protons in the space environment. The considered investigation is concerned with the effect of periodic thermal annealing on the deep-level defects induced by the 200 keV protons in the AlGaAs-GaAs solar cells. Protons at a fluence of 10 to the 11th P/sq cm were used in the irradiation cycle, while annealing temperatures of 200 C (for 24 hours), 300 C (six hours), and 400 C (six hours) were employed. The most likely candidate for the E(c) -0.71 eV electron trap observed in the 200 keV proton irradiated samples may be due to GaAs antisite, while the observed E(v) +0.18 eV hole trap has been attributed to the gallium vacancy related defect. The obtained results show that periodic annealing in the considered case does not offer any advantages over the one time annealing process.

  4. Axillary irradiation omitting axillary dissection in breast cancer: is there a role for shoulder-sparing proton therapy?

    Science.gov (United States)

    Farace, P; Deidda, M A; Amichetti, M

    2015-10-01

    The recent EORTC 10981-22023 AMAROS trial showed that axillary radiotherapy and axillary lymph node dissection provide comparable local control and reduced lymphoedema in the irradiated group. However, no significant differences between the two groups in range of motion and quality of life were reported. It has been acknowledged that axillary irradiation could have induced some toxicity, particularly shoulder function impairment. In fact, conventional breast irradiation by tangential beams has to be modified to achieve full-dose coverage of the axillary nodes, including in the treatment field a larger portion of the shoulder structures. In this scenario, alternative irradiation techniques were discussed. Compared with modern photon techniques, axillary irradiation by proton therapy has the potential for sparing the shoulder without detrimental increase of the medium-to-low doses to the other normal tissues.

  5. Optimal conditions for high current proton irradiations at the university of Wisconsin's ion beam laboratory

    International Nuclear Information System (INIS)

    Wetteland, C. J.; Field, K. G.; Gerczak, T. J.; Eiden, T. J.; Maier, B. R.; Albakri, O.; Sridharan, K.; Allen, T. R.

    2013-01-01

    The National Electrostatics Corporation's (NEC) Toroidal Volume Ion Source (TORVIS) source is known for exceptionally high proton currents with minimal service downtime as compared to traditional sputter sources. It has been possible to obtain over 150μA of proton current from the source, with over 70μA on the target stage. However, beam fluxes above ∼1×10 17 /m2-s may have many undesirable effects, especially for insulators. This may include high temperature gradients at the surface, sputtering, surface discharge, cracking or even disintegration of the sample. A series of experiments were conducted to examine the role of high current fluxes in a suite of ceramics and insulating materials. Results will show the optimal proton irradiation conditions and target mounting strategies needed to minimize unwanted macro-scale damage, while developing a procedure for conducting preliminary radiation experiments.

  6. Estimating the effectiveness of human-cell irradiation by protons of a therapeutic beam of the joint institute for nuclear research phasotron using cytogenetic methods

    Science.gov (United States)

    Zaytseva, E. M.; Govorun, R. D.; Mitsin, G. V.; Molokanov, A. G.

    2011-11-01

    The effectiveness of the impact of therapeutic proton beams in human cells with respect to the criterion of formation of chromosome aberrations in human-blood lymphocytes is estimated. The physical characteristics of radiation (proton LET at the input of the object and in the region of the modified Bragg peak) and the role of the biological factor (the differences in the radiosensitivity of nondividing cells corresponding to the irradiation of normal tissues along the proton-beam path and tumor tissues) are taken into account. The relative biological effectiveness of protons is ˜1 at the beam input of the object and ˜1.2 in the Bragg peak region. Taking into account the higher radiosensitivity of dividing cells in the G 2 phase of the cell cycle, the irradiation effectiveness increases to ˜1.4.

  7. Calculations of the displacement damage and short-circuit current degradation in proton irradiated (AlGa)As-GaAs solar cells

    Science.gov (United States)

    Yeh, C. S.; Li, S. S.; Loo, R. Y.

    1987-01-01

    A theoretical model for computing the displacement damage defect density and the short-circuit current (I sub sc) degradation in proton-irradiated (AlGa)As-GaAs p-n junction solar cells is presented. Assumptions were made with justification that the radiation induced displacement defects form an effective recombination center which controls the electron and hole lifetimes in the junction space charge region and in the n-GaAs active layer of the irradiated GaAs p-n junction cells. The degradation of I sub sc in the (AlGa)As layer was found to be negligible compared to the total degradation. In order to determine the I sub sc degradation, the displacement defect density, path length, range, reduced energy after penetrating a distance x, and the average number of displacements formed by one proton scattering event were first calculated. The I sub sc degradation was calculated by using the electron capture cross section in the p-diffused layer and the hole capture cross section in the n-base layer as well as the wavelength dependent absorption coefficients. Excellent agreement was found between the researchers calculated values and the measured I sub sc in the proton irradiated GaAs solar cells for proton energies of 100 KeV to 10 MeV and fluences from 10 to the 10th power p/square cm to 10 to the 12th power p/square cm.

  8. Radiation damage in proton-irradiated epitaxial silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Joern

    2009-07-15

    In this work radiation hardness of 75 {mu}m, 100 {mu}m and 150 {mu}m thick epitaxial silicon pad diodes of both standard and oxygenated material was investigated. Damage after 24 GeV/c proton irradiation in a 1MeV neutron equivalent fluence range between 10{sup 14} cm{sup -2} and 10{sup 16} cm{sup -2} was studied and isothermal annealing experiments at 80 C were carried out. Standard CV/IV measurements could be performed up to 4 x 10{sup 15} cm{sup -2}. The volume-normalised reverse current was found to increase linearly with fluence with a slope independent of the thickness and impurity concentration. However, due to large fluctuations the fluences had to be renormalised using the current-related damage parameter. Concerning the depletion voltage, nearly all materials remained at a moderate level up to 4 x 10{sup 15} cm{sup -2}. During short-term annealing acceptors annealed out, whereas others were introduced during the long-term annealing. The stable damage was characterised by donor removal at low fluences and fluence-proportional predominant donor introduction for highly irradiated diodes, depending on the oxygen level. No type inversion was observed. Time-resolved measurements with a new 670 nm laser-TCT setup made the determination of the trapping time constant with the charge correction method possible. The results agreed with expectations and showed a linear increase of trapping probability with fluence. The electric field exhibited a double peak structure in highly irradiated diodes. Charge collection efficiency measurements with {alpha}-particles were independent of oxygen concentration, but showed an improved efficiency for thinner diodes. A comparison to simulation revealed systematic discrepancies. A non-constant trapping time parameter was proposed as possible solution. (orig.)

  9. Radiation damage in proton-irradiated epitaxial silicon detectors

    International Nuclear Information System (INIS)

    Lange, Joern

    2009-07-01

    In this work radiation hardness of 75 μm, 100 μm and 150 μm thick epitaxial silicon pad diodes of both standard and oxygenated material was investigated. Damage after 24 GeV/c proton irradiation in a 1MeV neutron equivalent fluence range between 10 14 cm -2 and 10 16 cm -2 was studied and isothermal annealing experiments at 80 C were carried out. Standard CV/IV measurements could be performed up to 4 x 10 15 cm -2 . The volume-normalised reverse current was found to increase linearly with fluence with a slope independent of the thickness and impurity concentration. However, due to large fluctuations the fluences had to be renormalised using the current-related damage parameter. Concerning the depletion voltage, nearly all materials remained at a moderate level up to 4 x 10 15 cm -2 . During short-term annealing acceptors annealed out, whereas others were introduced during the long-term annealing. The stable damage was characterised by donor removal at low fluences and fluence-proportional predominant donor introduction for highly irradiated diodes, depending on the oxygen level. No type inversion was observed. Time-resolved measurements with a new 670 nm laser-TCT setup made the determination of the trapping time constant with the charge correction method possible. The results agreed with expectations and showed a linear increase of trapping probability with fluence. The electric field exhibited a double peak structure in highly irradiated diodes. Charge collection efficiency measurements with α-particles were independent of oxygen concentration, but showed an improved efficiency for thinner diodes. A comparison to simulation revealed systematic discrepancies. A non-constant trapping time parameter was proposed as possible solution. (orig.)

  10. Modeling and analysis of all the positron emitters simulation steps generated during the treatment phase in proton-therapy - from the beam to the PET camera - for the follow-up of the irradiations

    International Nuclear Information System (INIS)

    Ty, C.V.N.

    2012-01-01

    The proton-therapy is an innovative technique for cancer treatment in critical areas, such as the eye or the head. Even though the interaction of protons with human tissues is a well-known physical phenomenon which gives rise to the proton-therapy, there are uncertainties on the proton trajectory due to heterogeneities in the irradiated tissue, the calculation of the beam parameters in the planning treatment affects the theoretical benefits of the protons and the chosen dose delivery process. Thus, methods for irradiation quality control have been suggested. Most of them rely on utilizing the mapping of the positron emitters generated during the irradiation. They are detectable and quantifiable thanks to the use of the PET (positron emitter tomography), a medical imaging technique mainly used for the cancer expansion assessment. PET acquisitions were proposed and then realized on phantoms and patients after proton-therapy. The quality control relies on comparing the measured radioactive distribution to the simulated β + distribution. The modeling of the positron activity generated by protons in the irradiated area can be divided into three steps: the simulation of the proton beam, the modeling of the proton interactions in the irradiated object and the modeling of the PET acquisition. Different ways of simulating these steps are possible. This PhD work suggests different ways of modeling the three steps and evaluates theirs benefits for the irradiation quality control. We have restrained our evaluation to the verification of the proton range and to the uncertainties related to the proton range. This research work utilizes on irradiations in homogenous and inhomogeneous areas in a head model. We have compared the uncertainties on the proton range measured thanks to the following β + distributions: 1) A β + distribution obtained by modeling the irradiation with a proton beam simulated analytically and simulated using the complete Monte Carlo method; 2) A Monte

  11. Proton irradiation and endometriosis

    International Nuclear Information System (INIS)

    Wood, D.H.; Yochmowitz, M.G.; Salmon, Y.L.; Eason, R.L.; Boster, R.A.

    1983-01-01

    It was found that female rhesus monkeys given single total-body exposures of protons of varying energies developed endometriosis at a frequency significantly higher than that of nonirradiated animals of the same age. The minimum latency period was determined to be 7 years after the proton exposure. The doses and energies of the radiation received by the experimental animals were within the range that could be received by an aircrew member in near-earth orbit during a random solar flare event. It is concluded that endometriosis should be a consideration in assessing the risk of delayed radiation effects in female crew members. 15 references

  12. Maiden Voyage of the Under-Ice Float

    Science.gov (United States)

    Shcherbina, A.; D'Asaro, E. A.; Light, B.; Deming, J. W.; Rehm, E.

    2016-02-01

    The Under-Ice Float (UIF) is a new autonomous platform for sea ice and upper ocean observations in the marginal ice zone (MIZ). UIF is based on the Mixed Layer Lagrangian Float design, inheriting its accurate buoyancy control and relatively heavy payload capability. A major challenge for sustained autonomous observations in the MIZ is detection of open water for navigation and telemetry surfacings. UIF employs the new surface classification algorithm based on the spectral analysis of surface roughness sensed by an upward-looking sonar. A prototype UIF was deployed in the MIZ of the central Arctic Ocean in late August 2015. The main payload of the first UIF was a bio-optical suit consisting of upward- and downward hyperspectral radiometers; temperature, salinity, chlorophyll, turbidity, and dissolved oxygen sensors, and a high-definition photo camera. In the early stages of its mission, the float successfully avoided ice, detected leads, surfaced in open water, and transmitted data and photographs. We will present the analysis of these observations from the full UIF mission extending into the freeze-up season.

  13. Proton Testing of Advanced Stellar Compass Digital Processing Unit

    DEFF Research Database (Denmark)

    Thuesen, Gøsta; Denver, Troelz; Jørgensen, Finn E

    1999-01-01

    The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland.......The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland....

  14. Estimation of mutation rates induced by large doses of gamma, proton and neutron irradiation of the X-chromosome of the nematode Panagrellus redivivus

    International Nuclear Information System (INIS)

    Denich, K.T.R.; Samoiloff, M.R.

    1984-01-01

    The radiation-resistant free-living nematode Panagrellus redivivus was used to study mutation rates in oocytes, following gamma, proton and neutron irradiation in the dose range 45-225 grays. γ-Radiation produced approximately 0.001 lethal X-chromosomes per gray over the range tested. Proton or neutron irradiation produced approximately 0.003 lethal X-chromosomes per gray at lower doses, with the mutation rate dropping to 0.001 lethal X-chromosome per gray at the higher doses. These results suggest a dose-dependent mutation-repair system. Cell lethality was also examined. γ-Radiation produced the greatest amount of cell lethality at all doses, while neutron irradiation had no cell lethal effect at any of the doses examined. (orig.)

  15. Growth of large size lithium niobate single crystals of high quality by tilting-mirror-type floating zone method

    Energy Technology Data Exchange (ETDEWEB)

    Sarker, Abdur Razzaque, E-mail: razzaque_ru2000@yahoo.com [Department of Physics, University of Rajshahi (Bangladesh)

    2016-05-15

    Large size high quality LiNbO{sub 3} single crystals were grown successfully by tilting-mirror-type floating zone (TMFZ) technique. The grown crystals were characterized by X-ray diffraction, etch pits density measurement, Impedance analysis, Vibrating sample magnetometry (VSM) and UV-Visible spectrometry. The effect of mirror tilting during growth on the structural, electrical, optical properties and defect density of the LiNbO{sub 3} crystals were investigated. It was found that the defect density in the crystals reduced for tilting the mirror in the TMFZ method. The chemical analysis revealed that the grown crystals were of high quality with uniform composition. The single crystals grown by TMFZ method contains no low-angle grain boundaries, indicating that they can be used for high efficiency optoelectronic devices. (author)

  16. Development of useful genetic resources by proton-beam irradiation

    International Nuclear Information System (INIS)

    Kim, In Gyu; Kim, Kug Chan; Park, Hyi Gook; Jung, Il Lae; Seo, Yong Won; Chang, Chul Seong; Kim, Jae Yoon; Ham, Jae Woong

    2005-08-01

    The aim of this study is to develop new, useful and high-valuable genetic resources through the overproduction of biodegradable plastics and the propagation of wheat using proton-beam irradiation. Useful host strain was isolated through the mutagenization of the Escherichia coli K-12 strain, followed by characterizing the genetic and physiological properties of the E. coli mutant strains. The selected E. coli mutant strain produced above 85g/L of PHB, showed above 99% of PHB intracellular content and spontaneously liberated intracellular PHB granules. Based on the results, the production cost of PHB has been estimated to approximately 2$/kg, leading effective cost-down. Investigated the propagation of wheat and its variation, a selectable criterion of wet pro of was established and genetic analysis of useful mutant was carried out

  17. On the modeling of irradiation-induced homogeneous precipitation in proton-bombarded Ni-Si solid solutions

    Science.gov (United States)

    Lam, Nghi Q.; Janghorban, K.; Ardell, A. J.

    1981-10-01

    Irradiation-induced solute redistribution leading to precipitation of coherent γ' particles in undersaturated Ni-based solid solutions containing 6 and 8 at.% Si during 400-keV proton bombardment was modeled, based on the concept of solute segregation in concentrated alloys under spatially-dependent defect production conditions. The combined effects of (i) an extremely large difference between the defect production rates in the peak-damage and mid-range regions during irradiation and (ii) a preferential coupling between the interstitial and solute fluxes generate a net transient flux of Si atoms into the mid-range region, which is much larger than the solute flux out of this location. As a result, the Si concentration exceeds the solubility limit and homogeneous precipitation of the γ' phase occurs in this particular region of the irradiated samples. The spatial, compositional and temperature dependences of irradiation-induced homogeneous precipitation derived from the present theoretical calculations are in good qualitative agreement with experimental observations

  18. Proton flux under radiation belts: near-equatorial zone

    International Nuclear Information System (INIS)

    Grigoryan, O.R.; Panasyuk, M.I.; Petrov, A.N.; Kudela, K.

    2005-01-01

    In this work the features of low-energy proton flux increases in near-equatorial region (McIlvein parameter L th the proton flux (with energy from tens keV up to several MeV) increases are registering regularly. However modern proton flux models (for example AP8 model) works at L>1.15 only and does not take into account near-equatorial protons. These fluxes are not too big, but the investigation of this phenomenon is important in scope of atmosphere-ionosphere connections and mechanisms of particles transport in magnetosphere. In according to double charge-exchange model the proton flux in near-equatorial region does not depend on geomagnetic local time (MLT) and longitude. However the Azur satellite data and Kosmos-484, MIR station and Active satellite data revealed the proton flux dependence on longitude. The other feature of near-equatorial proton flux is the dependence on geomagnetic local time revealed in the Sampex satellite experiment and other experiments listed above. In this work the dependences on MLT and longitude are investigated using the Active satellite (30-500 keV) and Sampex satellite (>800 keV). This data confirms that main sources of near-equatorial protons are radiation belts and ring current. The other result is that near-equatorial protons are quasi-trapped. The empirical proton flux dependences on L, B at near-equatorial longitudes are presented. (author)

  19. Diagnostic X-Ray dosimeters using standard Float Zone (FZ) and XRA-50 commercial diodes

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Josemary A.C.; Bueno, Carmen C., E-mail: josemary@ipen.br, E-mail: ccbueno@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), São Paulo, SP (Brazil); Barros, Vinicius S.M.; Asfora, Viviane K.; Khoury, Helen J., E-mail: vsmdbarros@gmail.com, E-mail: vikhoury@gmail.com, E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Física

    2017-07-01

    The results obtained with a standard float zone (FZ) silicon diode, processed at the Helsinki Institute of Physics, used as on-line diagnostic X-ray dosimeter are described in this work. The device was connected in the short circuit current mode to the input of an integrating electrometer. The response repeatability and the current sensitivity coefficient of the diode were measured with diagnostic X-ray beams in the range of 40-80 kV. The dose-response of the device, evaluated from 10 mGy up to 500 mGy, was linear with high charge sensitivity. Nevertheless, significant energy dependence was observed in the charge sensitivity of FZ device for energies below 70 kV. The dosimetric characteristics of this FZ diode were compared to those of an XRA-50 commercial Si diode, specially designed to X-ray dosimetry. The results obtained with the FZ diode evidenced that it can be an alternative choice for diagnostic X-ray dosimetry, although it needs to be calibrated for individual X-ray beam energies. The studies of long-term stability and the radiation hardness of these diodes are under way. (author)

  20. Optical spectroscopy of vacancy related defects in silicon carbide generated by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, C.; Sperlich, A.; Simin, D.; Astakhov, G.V. [Experimental Physics VI, Julius Maximilian University of Wuerzburg (Germany); Kraus, H. [Japan Atomic EnergyAgency, Takasaki, Gunma (Japan); Experimental Physics VI, Julius Maximilian University of Wuerzburg (Germany); Makino, T.; Sato, S.I.; Ohshima, T. [Japan Atomic EnergyAgency, Takasaki, Gunma (Japan); Dyakonov, V. [Experimental Physics VI, Julius Maximilian University of Wuerzburg (Germany); ZAE Bayern, Wuerzburg (Germany)

    2016-07-01

    Defects in silicon carbide (SiC) received growing attention in recent years, because they are promising candidates for spin based quantum information processing. In this study we examine silicon vacancies in 4H-SiC crystals generated by proton irradiation. By the use of confocal microscopy the implantation depth of Si vacancies for varying proton energies can be verified. An important issue is to ascertain the nature and distribution of the defects. For this purpose, we use the characteristic photoluminescence spectrum of Si vacancies, whose intensity is proportional to the defect density. Using xyz-scans, where the photoluminescence at each mapping point is recorded, one can thus determine the vacancies nature and their distribution in the SiC crystal. Additionally we verify the nature of the examined defects by measuring their uniquely defined zero-field-splitting by using ODMR associated with defect spins.

  1. Study on 150μm thick n- and p-type epitaxial silicon sensors irradiated with 24 GeV/c protons and 1 MeV neutrons

    International Nuclear Information System (INIS)

    Kaska, Katharina; Moll, Michael; Fahrer, Manuel

    2010-01-01

    A study on 150μm epitaxial (EPI) n- and p-type silicon diodes irradiated with neutrons up to 8x10 15 n/cm 2 and protons up to 1.7x10 15 p/cm 2 has been performed by means of CV/IV, charge collection efficiency (CCE) and transient current technique (TCT) measurements. It is found that the effective space charge density increases three times faster after proton than after neutron irradiation with a slightly higher effective space charge generation rate for n-type material compared to p-type material. A drop in charge collection efficiency already at fluences of 1x10 12 n eq /cm 2 can be seen in n-type material, but is absent in p-type material. TCT measurements show space charge sign inversion from positive to negative charge in n-type material after neutron irradiation and from negative to positive space charge in p-type material after proton irradiation. No difference was found in the response of diodes manufactured by different producers out of the same wafer material.

  2. Study of the iron corrosion at the interface of different media (water, air) submitted to protons irradiation

    International Nuclear Information System (INIS)

    Lapuerta, S.

    2005-10-01

    During the deep geological disposal, stainless steel containers of the vitrified waste will be put in carbon steel overpacks. After the closing of the storage site, overpacks will be in contact with a humid air and a radioactive medium. After hundred years, overpacks could be in contact with water radiolysis in an anoxic medium. In this context, my PhD work is a fundamental study which is the understanding of the corrosion mechanisms of pure iron under proton irradiation. This corrosion is affected by the contact of iron with different atmospheres (air, nitrogen) and water. In the case of the atmospheric iron corrosion under irradiation, we have studied the influence of the proton beam flux. During this work, we have characterized the structure of the oxides formed at the iron surface. The structure formed does not correspond to iron oxides and hydroxides indexed. However, we have shown that the oxide structure is close to that of lepidocrocite and bernalite. Moreover, we have determined the oxygen diffusion coefficient in iron under irradiation and we have shown that the irradiation accelerates of 6 orders of magnitude the iron corrosion. In addition, the irradiations which were realized in different gas have put in evidence the negligible role of nitrates, and the importance of the O 2 /H 2 O coupling on the iron corrosion. Finally, we have shown the influence of the relative humidity, the maximum of the corrosion being observed for a relative humidity close to 45%. In the case of the iron corrosion in aqueous media under irradiation, the influence of the oxygen dissolved in water has been studied using a surface marker. We have put in evidence that the corrosion is twice more significant in aerated medium than in deaerated medium. Moreover, the influence of radicals has been shown. An irradiated sample is more corroded than a sample put in contact with a H 2 O 2 solution. Finally, the follow-up of the iron potential under irradiation have shown the majority role

  3. Effect of 520 MeV Kr{sup 20+} ion irradiation on the critical current density of Bi-2212 single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Terai, Takayuki; Ito, Yasuyuki [Tokyo Univ. (Japan). Faculty of Engineering; Kishio, Kouji

    1996-10-01

    Change in magnetic properties of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+y} (Bi-2212) single crystals due to Kr{sup 20+} ion irradiation is reported, focused on critical current density and irreversibility magnetic field. The Bi-2212 single crystal specimens (3x3x0.3 mm{sup 3}) were prepared by the floating zone method. Each specimen was irradiated with 520 MeV Kr{sup 20+} ions of 10{sup 10}-10{sup 11} cm{sup -2} in the fluence. Magnetic hysteresis was measured at 4.2K-60K with a vibrating sample magnetometer before and after irradiation. Very large enhancement was observed in critical current density and irreversibility magnetic field above 20K. (author)

  4. Advancements of floating strip Micromegas detectors for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Klitzner, Felix; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard [LS Schaile, LMU Muenchen (Germany); Magallanes, Lorena [LS Parodi, LMU Muenchen (Germany); Universitaetsklinikum Heidelberg (Germany); Parodi, Katia [LS Parodi, LMU Muenchen (Germany); Heidelberger Ionenstrahl Therapiezentrum (Germany); Voss, Bernd [Gesellschaft fuer Schwerionenforschung, Darmstadt (Germany)

    2016-07-01

    Floating strip Micromegas have proven to be high-rate capable tracking detectors with excellent spatial and temporal resolution for particle fluxes up to 7 MHz/cm{sup 2}. To further increase the high-rate capability a Ne:CF{sub 4} 86:14 vol.% gas mixture has been used as detector gas. We present results from measurements with a seven detector system consisting of six low material budget floating strip Micromegas, a GEM detector and a scintillator based particle range telescope. The gaseous and the scintillation detectors were read out with APV25 frontend boards, allowing for single strip readout with pulse height and timing information. A two-dimensional readout anode for floating strip Micromegas has been tested for the first time. The Micromegas detectors were operated with minimal additional drift field, which significantly improves the timing resolution and also the spatial resolution for inclined tracks. We discuss the detector performance in high-rate carbon and proton beams at the Heidelberg Ion Beam Therapy Center (HIT) and present radiographies of phantoms, acquired with the system.

  5. SU-F-T-150: Comparing Normal Tissue Irradiated Volumes for Proton Vs. Photon Treatment Plans On Lung Patients

    Energy Technology Data Exchange (ETDEWEB)

    Liu, A; Mohan, R; Liao, Z [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: The aim of this work is to compare the “irradiated volume” (IRV) of normal tissues receiving 5, 20, 50, 80 and 90% or higher of the prescription dose with passively scattered proton therapy (PSPT) vs. IMRT of lung cancer patients. The overall goal of this research is to understand the factors affecting outcomes of a randomized PSPT vs. IMRT lung trial. Methods: Thirteen lung cancer patients, selected randomly, were analyzed. Each patient had PSPT and IMRT 74 Gy (RBE) plans meeting the same normal tissue constraints generated. IRVs were created for pairs of IMRT and PSPT plans on each patient. The volume of iGTV, (respiratory motion-incorporated GTV) was subtracted from each IRV to create normal tissue irradiated volume IRVNT. The average of IRVNT DVHs over all patients was also calculated for both modalities and inter-compared as were the selected dose-volume indices. Probability (p value) curves were calculated based on the Wilcoxon matched-paired signed-rank test to determine the dose regions where the statistically significant differences existed. Results: As expected, the average 5, 20 and 50% IRVNT’s for PSPT was found to be significantly smaller than for IMRT (p < 0.001, 0.01, and 0.001 respectively). However, the average 90% IRVNT for PSPT was greater than for IMRT (p = 0.003) presumably due to larger penumbra of protons and the long range of protons in lower density media. The 80% IRVNT for PSPT was also larger but not statistically distinguishable (p = .224). Conclusion: PSPT modality has smaller irradiated volume at lower doses, but larger volume at high doses. A larger cohort of lung patients will be analyzed in the future and IRVNT of patients treated with PSPT and IMRT will be compared to determine if the irradiated volumes (the magnitude of “dose bath”) correlate with outcomes.

  6. Microscopic evaluation of nuclear foci (gamma H2AX) in cells irradiated with protons and lithium ions

    International Nuclear Information System (INIS)

    Bracalente, C.; Molinari, Beatriz L.; Duran, Hebe; Ibanez, I.; Palmieri, M.; Kreiner, Andres J.; Burlon, Alejandro; Valda, Alejandro; Davidson, J.; Davidson, M.; Vazquez, Monica; Ozafran, Mabel J.

    2007-01-01

    Full text: The special properties of both physical and biological radiation particles with high-LET (Linear Transfer of Energy) have led to its increased use in cancer therapy. In this work, the effect of high and low LET radiation on cell lines with different radiosensitivity (Irs-20 and CHO-10B2) quantifying the number and size of nuclear foci obtained from histone H2AX (γH2AX) phosphorylation which plays an important role in DNA damage reparation is compared. Foci detection was performed by immunocytochemical methods and fluorescence microscopy. The cells cultures were irradiated with plateau-phase protons (14 MeV, LET: 3 keV/μ), on Bragg peak (3 MeV. LET: 14 KeV/μ) and with Lithium ions (7 MeV, LET: 250 KeV//μ) on the Tandar accelerator. A clonogenic analysis of the two cell lines was made. Irradiation with protons (low LET) showed a significant difference (p [es

  7. Ion Prostate Irradiation (IPI) – a pilot study to establish the safety and feasibility of primary hypofractionated irradiation of the prostate with protons and carbon ions in a raster scan technique

    International Nuclear Information System (INIS)

    Habl, Gregor; Herfarth, Klaus; Hatiboglu, Gencay; Edler, Lutz; Uhl, Matthias; Krause, Sonja; Roethke, Matthias; Schlemmer, Heinz P; Hadaschik, Boris; Debus, Juergen

    2014-01-01

    Due to physical characteristics, ions like protons or carbon ions can administer the dose to the target volume more efficiently than photons since the dose can be lowered at the surrounding normal tissue. Radiation biological considerations are based on the assumption that the α/β value for prostate cancer cells is 1.5 Gy, so that a biologically more effective dose could be administered due to hypofractionation without increasing risks of late effects of bladder (α/β = 4.0) and rectum (α/β = 3.9). The IPI study is a prospective randomized phase II study exploring the safety and feasibility of primary hypofractionated irradiation of the prostate with protons and carbon ions in a raster scan technique. The study is designed to enroll 92 patients with localized prostate cancer. Primary aim is the assessment of the safety and feasibility of the study treatment on the basis of incidence grade III and IV NCI-CTC-AE (v. 4.02) toxicity and/or the dropout of the patient from the planned therapy due to any reason. Secondary endpoints are PSA-progression free survival (PSA-PFS), overall survival (OS) and quality-of-life (QoL). This pilot study aims at the evaluation of the safety and feasibility of hypofractionated irradiation of the prostate with protons and carbon ions in prostate cancer patients in an active beam technique. Additionally, the safety results will be compared with Japanese results recently published for carbon ion irradiation. Due to the missing data of protons in this hypofractionated scheme, an in depth evaluation of the toxicity will be created to gain basic data for a following comparison study with carbon ion irradiation. Clinical Trial Identifier: http://clinicaltrials.gov/show/NCT01641185 (clinicaltrials.gov)

  8. Effect of Proton Beam on Cancer Progressive and Metastatic Enzymes

    International Nuclear Information System (INIS)

    Sohn, Y. H.; Nam, K. S.; Oh, Y. H.; Kim, M. K.; Kim, M. Y.; Jang, J. S.

    2008-04-01

    The purpose of this study was to investigate the effect of proton beam on enzymes for promotion/progression of carcinogenesis and metastasis of malignant tumor cells to clarify proton beam-specific biological effects. The changes of cancer chemopreventive enzymes in human colorectal adenocarcinoma HT-29 cells irradiated with proton beams were tested by measuring the activities of quinine reductase (QR), glutathione S-transferase (GST), and ornithine decarboxylase (ODC), glutathione (GSH) levels, and expression of cyclooxygenase-2 (COX-2). We also examined the effect of proton beam on the ODC activity and expression of COX-2 in human breast cancer cell. We then assessed the metastatic capabilities of HT-29 and MDA-MB-231 cells irradiated with proton beam by measuring the invasiveness of cells through Matrigel-coated membrane and 12-O-tetradecanoylphorbol-13-acetate (TPA)-induced MMP activity in MDA-MB-231 and HT-29 cells. QR activity of irradiated HT-29 cells was slightly increased. Proton irradiation at dose of 32 Gy in HT-29 cells increased GST activity by 1.23-fold. In addition GSH levels in HT-29 cells was significantly increased 1.23- (p<0.05), 1.32- (p<0.01) and 1.34-fold (p<0.01) with the proton irradiation at doses of 8, 16 and 32 Gy, respectively. These results suggest that colon cancer chemopreventive activity was increased with the proton irradiation by increasing QR and GST activities and GSH levels and inhibiting ODC activity. Proton ion irradiation decreased the invasiveness of TPA-treated HT-29 cells and MDA-MB-231 cells through Matrigel-coated membrane. Proton ion irradiation pretreatment decreased TPA-induced MMP activity in MDA-MB-231 and HT-29 cells. Further studies are necessary to investigate if these findings could be translated to in vivo situations

  9. Isolation of radiothallium from proton irradiated lead by means of sorption from solutions on ammonium 12-molybdophosphate and by gas thermochromatography

    International Nuclear Information System (INIS)

    Deptula, Ch.; Zajtseva, N.G.; Kim Sen Khan; Knotek, O.; Mikets, P.; Khalkin, V.A.

    1987-01-01

    Tl ultramicroquantity adsorption from lead nitric acid solutions by ammonium 12-molybdophosphate, fixed in a matrix of porous Teflon (by AMP-sorbent) is investigated. It is shown that efficient Tl and Pb separation occurs during adsorption. Process of Tl washing from AMP-sorbent are studied and it is detected, that a complete Tl extraction is achieved under AMP dissolution in concentrated ammonium. Subsequent Tl refinement and concentration are performed by cation exchange chromatography on cationites dowex 50 or KU-2. During investigation into Tl ultramicroquantity behaviour in Pb melt it is shown that Tl is quantitatively isolated into a gaseous phase under the application of fluorinating agents-PbF 2 or NaF solid salt additions, covering the melt surface. Radiothallium is removed from evaporation zone by inert gas (He or N 2 ) flow into thermochromatographic column, where it is precipitated in a limited zone with maximum at ∼240 deg C. Based on the results obtained, liquid and gaseous methods for radiothallium isolation from proton irradiated lead are developed. Radiothallium is characterized by radionuclide, radiochemical and chemical purity, necessary in nuclear medicine for 201 Tl preparations. Both methods provide for a chemical yield of ≅95% and it takes about two hours for their realization

  10. Radiation exposure during in-vivo analysis of human dental enamel by proton irradiation

    International Nuclear Information System (INIS)

    Baijot-Stroobants, J.; Bodart, F.; Deconninck, G.; Vreven, J.

    Fluorine can be analysed by proton activation, with detection of prompt γ-rays. Using external beams, it is possible to make in-vivo determinations and to follow the concentration in fluoridated enamel. Radiation damage and radiation hazards are investigated. It is found that the dose rate is very small and that the technique can be used without radiation problems. Local destruction on the enamel surface is investigated using a scanning microscope, no modification is observed in the cristallite structure after irradiation. (author)

  11. Genetic effects of prolonged combined irradiation of laboratory animals in Chernobyl Atomic Power Plant alienation zone

    International Nuclear Information System (INIS)

    Savtsova, Z.D.; Vojejkova, Yi.M.; Dzhaman, N.Yi.; Yudyina, O.Yu.; Yindik, V.M.; Kovbasyuk, S.A.

    2000-01-01

    Prolonged combined (external and internal) irradiation of mice in the r zone of the Chernobyl Atomic Power Plant caused hereditary disturbances physiological defects in the posterity irrespective of the fact if one or both parents were irradiated. The most favourable indices were observed in F2 posterity of the both exposed parents

  12. A floating water bridge produces water with excess charge

    Science.gov (United States)

    Fuchs, Elmar C.; Sammer, Martina; Wexler, Adam D.; Kuntke, Philipp; Woisetschläger, Jakob

    2016-03-01

    Excess positive and negative Bjerrum-defect like charge (protonic and ‘aterprotonic’, from ancient Greek ἄ'τɛρ, ‘without’) in anolyte and catholyte of high voltage electrolysis of highly pure water was found during the so-called ‘floating water bridge’ experiment. The floating water bridge is a special case of an electrohydrodynamic liquid bridge and constitutes an intriguing phenomenon that occurs when a high potential difference (~kV cm-1) is applied between two beakers of water. To obtain such results impedance spectroscopy was used. This measurement technique allows the depiction and simulation of complex aqueous systems as simple electric circuits. In the present work we show that there is an additional small contribution from the difference in conductivity between anolyte and catholyte which cannot be measured with a conductivity meter, but is clearly visible in an impedance spectrum.

  13. Radiation damage and defect behavior in proton irradiated lithium-counterdoped n/sup +/p silicon solar cells

    International Nuclear Information System (INIS)

    Stupica, J.; Goradia, C.; Swartz, C.K.; Weinberg, I.

    1987-01-01

    Two lithium-counterdoped n/sup +/p silicon solar cells with different lithium concentrations were irradiated by 10 MeV protons. Cell performance was measured as a function of fluence, and it was found that the cell with the highest concentration of lithium had the higher radiation resistance. Deep level defects were studied using deep level transient spectroscopy which yielded two defects that were lithium related. Relating the defect energy levels obtained from this study under 10 MeV protons, with an earlier work using 1 MeV electron irradiations shows no correlation of the defect energy levels. There is one marked comparison though. The absence of the boron interstitial-oxygen interstitial defect. This consistency strengthens the belief that lithium interacts with oxygen to prevent the formation of the boron interstitial-oxygen interstitial defect. The present results indicate that, in general, addition of lithium in small amounts to the p-base of a boron doped silicon solar cell such that the base remains p-type, tends to increase the radiation resistance of the cell

  14. Induction and Rejoining of DNA Double Strand Breaks Assessed by H2AX Phosphorylation in Melanoma Cells Irradiated with Proton and Lithium Beams

    International Nuclear Information System (INIS)

    Ibanez, Irene L.; Bracalente, Candelaria; Molinari, Beatriz L.; Palmieri, Monica A.; Policastro, Lucia; Kreiner, Andres J.; Burlon, Alejandro A.; Valda, Alejandro; Navalesi, Daniela; Davidson, Jorge; Davidson, Miguel; Vazquez, Monica; Ozafran, Mabel; Duran, Hebe

    2009-01-01

    Purpose: The aim of this study was to evaluate the induction and rejoining of DNA double strand breaks (DSBs) in melanoma cells exposed to low and high linear energy transfer (LET) radiation. Methods and Materials: DSBs and survival were determined as a function of dose in melanoma cells (B16-F0) irradiated with monoenergetic proton and lithium beams and with a gamma source. Survival curves were obtained by clonogenic assay and fitted to the linear-quadratic model. DSBs were evaluated by the detection of phosphorylated histone H2AX (γH2AX) foci at 30 min and 6 h post-irradiation. Results: Survival curves showed the increasing effectiveness of radiation as a function of LET. γH2AX labeling showed an increase in the number of foci vs. dose for all the radiations evaluated. A decrease in the number of foci was found at 6 h post-irradiation for low LET radiation, revealing the repair capacity of DSBs. An increase in the size of γH2AX foci in cells irradiated with lithium beams was found, as compared with gamma and proton irradiations, which could be attributed to the clusters of DSBs induced by high LET radiation. Foci size increased at 6 h post-irradiation for lithium and proton irradiations in relation with persistent DSBs, showing a correlation with surviving fraction. Conclusions: Our results showed the response of B16-F0 cells to charged particle beams evaluated by the detection of γH2AX foci. We conclude that γH2AX foci size is an accurate parameter to correlate the rejoining of DSBs induced by different LET radiations and radiosensitivity.

  15. Effect of impurities on the growth of {113} interstitial clusters in silicon under electron irradiation

    Science.gov (United States)

    Nakai, K.; Hamada, K.; Satoh, Y.; Yoshiie, T.

    2011-01-01

    The growth and shrinkage of interstitial clusters on {113} planes were investigated in electron irradiated Czochralski grown silicon (Cz-Si), floating-zone silicon (Fz-Si), and impurity-doped Fz-Si (HT-Fz-Si) using a high voltage electron microscope. In Fz-Si, {113} interstitial clusters were formed only near the beam incident surface after a long incubation period, and shrank on subsequent irradiation from the backside of the specimen. In Cz-Si and HT-Fz-Si, {113} interstitial clusters nucleated uniformly throughout the specimen without incubation, and began to shrink under prolonged irradiation at higher electron beam intensity. At lower beam intensity, however, the {113} interstitial cluster grew stably. These results demonstrate that the {113} interstitial cluster cannot grow without a continuous supply of impurities during electron irradiation. Detailed kinetics of {113} interstitial cluster growth and shrinkage in silicon, including the effects of impurities, are proposed. Then, experimental results are analyzed using rate equations based on these kinetics.

  16. Radiosensitivity of Patient-Derived Glioma Stem Cell 3-Dimensional Cultures to Photon, Proton, and Carbon Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chiblak, Sara; Tang, Zili [German Cancer Consortium, Heidelberg (Germany); Molecular and Translational Radiation Oncology, Heidelberg Ion Therapy Center, Heidelberg Institute of Radiation Oncology, University of Heidelberg Medical School and National Center for Tumor Diseases, German Cancer Research Center, Heidelberg (Germany); Campos, Benito; Gal, Zoltan; Unterberg, Andreas [Division of Neurological Research, Department of Neurosurgery, University of Heidelberg Medical School, Heidelberg (Germany); Debus, Jürgen [German Cancer Consortium, Heidelberg (Germany); Molecular and Translational Radiation Oncology, Heidelberg Ion Therapy Center, Heidelberg Institute of Radiation Oncology, University of Heidelberg Medical School and National Center for Tumor Diseases, German Cancer Research Center, Heidelberg (Germany); Herold-Mende, Christel [Division of Neurological Research, Department of Neurosurgery, University of Heidelberg Medical School, Heidelberg (Germany); Abdollahi, Amir, E-mail: a.amir@dkfz.de [German Cancer Consortium, Heidelberg (Germany); Molecular and Translational Radiation Oncology, Heidelberg Ion Therapy Center, Heidelberg Institute of Radiation Oncology, University of Heidelberg Medical School and National Center for Tumor Diseases, German Cancer Research Center, Heidelberg (Germany)

    2016-05-01

    Purpose: To investigate the radiosensitivity of primary glioma stem cell (GSC) cultures with different CD133 status in a 3-dimensional (3D) model after photon versus proton versus carbon irradiation. Methods and Materials: Human primary GSC spheroid cultures were established from tumor specimens of six consented glioblastoma patients. Human U87MG was used as a classical glioblastoma radioresistant cell line. Cell suspensions were generated by mechanical dissociation of GSC spheroids and embedded in a semi-solid 3D matrix before irradiation. Spheroid-like colonies were manually counted by microscopy. Cells were also recovered and quantified by fluorescence. CD133 expression and DNA damage were evaluated by flow cytometry. Results: The fraction of CD133{sup +} cells varied between 0.014% and 96% in the six GSC cultures and showed a nonsignificant correlation with plating efficiency and survival fractions. The 4 most photon-radioresistant GSC cultures were NCH644, NCH421k, NCH441, and NCH636. Clonogenic survival for proton irradiation revealed relative biologic effectiveness (RBE) in the range of 0.7-1.20. However, carbon irradiation rendered the photon-resistant GSC cultures sensitive, with average RBE of 1.87-3.44. This effect was partly attributed to impaired capability of GSC to repair carbon ion–induced DNA double-strand breaks as determined by residual DNA repair foci. Interestingly, radiosensitivity of U87 cells was comparable to GSC cultures using clonogenic survival as the standard readout. Conclusions: Carbon irradiation is effective in GSC eradication with similar RBE ranges approximately 2-3 as compared with non-stem GSC cultures (U87). Our data strongly suggest further exploration of GSC using classic radiobiology endpoints such as the here-used 3D clonogenic survival assay and integration of additional GSC-specific markers.

  17. Radiosensitivity of Patient-Derived Glioma Stem Cell 3-Dimensional Cultures to Photon, Proton, and Carbon Irradiation

    International Nuclear Information System (INIS)

    Chiblak, Sara; Tang, Zili; Campos, Benito; Gal, Zoltan; Unterberg, Andreas; Debus, Jürgen; Herold-Mende, Christel; Abdollahi, Amir

    2016-01-01

    Purpose: To investigate the radiosensitivity of primary glioma stem cell (GSC) cultures with different CD133 status in a 3-dimensional (3D) model after photon versus proton versus carbon irradiation. Methods and Materials: Human primary GSC spheroid cultures were established from tumor specimens of six consented glioblastoma patients. Human U87MG was used as a classical glioblastoma radioresistant cell line. Cell suspensions were generated by mechanical dissociation of GSC spheroids and embedded in a semi-solid 3D matrix before irradiation. Spheroid-like colonies were manually counted by microscopy. Cells were also recovered and quantified by fluorescence. CD133 expression and DNA damage were evaluated by flow cytometry. Results: The fraction of CD133"+ cells varied between 0.014% and 96% in the six GSC cultures and showed a nonsignificant correlation with plating efficiency and survival fractions. The 4 most photon-radioresistant GSC cultures were NCH644, NCH421k, NCH441, and NCH636. Clonogenic survival for proton irradiation revealed relative biologic effectiveness (RBE) in the range of 0.7-1.20. However, carbon irradiation rendered the photon-resistant GSC cultures sensitive, with average RBE of 1.87-3.44. This effect was partly attributed to impaired capability of GSC to repair carbon ion–induced DNA double-strand breaks as determined by residual DNA repair foci. Interestingly, radiosensitivity of U87 cells was comparable to GSC cultures using clonogenic survival as the standard readout. Conclusions: Carbon irradiation is effective in GSC eradication with similar RBE ranges approximately 2-3 as compared with non-stem GSC cultures (U87). Our data strongly suggest further exploration of GSC using classic radiobiology endpoints such as the here-used 3D clonogenic survival assay and integration of additional GSC-specific markers.

  18. Evaluation of critical resolved shear strength and deformation mode in proton-irradiated austenitic stainless steel using micro-compression tests

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hyung-Ha; Ko, Eunsol; Kwon, Junhyun; Hwang, Seong Sik [Nuclear Materials Safety Research Division, Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon, 305-353 (Korea, Republic of); Shin, Chansun, E-mail: c.shin@mju.ac.kr [Department of Materials Science and Engineering, Myongji University, 116 Myongji-ro, Cheoin-gu, Youngin, Gyeonggi-do, 449-728 (Korea, Republic of)

    2016-03-15

    Micro-compression tests were applied to evaluate the changes in the strength and deformation mode of proton-irradiated commercial austenitic stainless steel. Proton irradiation generated small dots at low dose levels and Frank loops at high dose levels. The increase in critical resolved shear stresses (CRSS) was measured from micro-compression of pillars and the Schmid factor calculated from the measured loading direction. The magnitudes of the CRSS increase were in good agreement with the values calculated from the barrier hardening model using the measured size and density of radiation defects. The deformation mode changed upon increasing the irradiation dose level. At a low radiation dose level, work hardening and smooth flow behavior were observed. Increasing the dose level resulted in the flow behavior changing to a distinct heterogeneous flow, yielding a few large strain bursts in the stress–strain curves. The change in the deformation mode was related to the formation and propagation of defect-free slip bands. The effect of the orientation of the pillar or loading direction on the strengths is discussed.

  19. Bilateral Floating Hip and Floating Knee: a Rare Complex Injury ...

    African Journals Online (AJOL)

    We report a rare complex injury of a 45-year-old man who sustained a bilateral floating hip and floating knee and hospitalised in our service six days after a traffic accident. The floating knees were open type III and II of Cauchoix score in phase of suppuration. He also presented with a floating ankle on the right side.

  20. Comparison of pad detectors produced on different silicon materials after irradiation with neutrons, protons and pions

    International Nuclear Information System (INIS)

    Kramberger, G.; Cindro, V.; Dolenc, I.; Mandic, I.; Mikuz, M.; Zavrtanik, M.

    2010-01-01

    A set of 44 pad detectors produced on p- and n-type MCz and Fz wafers was irradiated with 23 GeV protons, 200 MeV pions and reactor neutrons up to the equivalent fluences of Φ eq =3x10 15 cm -2 . The evolution of the full depletion voltage and the leakage current were monitored during short- and long-term annealing. At selected representative annealing steps, charge collection measurements were performed for all samples with LHC speed electronics. Measurements of full depletion voltage, leakage current and charge collection efficiency were compared for different irradiation particles and silicon materials.

  1. Comparison of pad detectors produced on different silicon materials after irradiation with neutrons, protons and pions

    Energy Technology Data Exchange (ETDEWEB)

    Kramberger, G., E-mail: Gregor.Kramberger@ijs.s [Jozef Stefan Institute and Department of Physics, University of Ljubljana, SI-1000 Ljubljana (Slovenia); Cindro, V.; Dolenc, I.; Mandic, I.; Mikuz, M.; Zavrtanik, M. [Jozef Stefan Institute and Department of Physics, University of Ljubljana, SI-1000 Ljubljana (Slovenia)

    2010-01-01

    A set of 44 pad detectors produced on p- and n-type MCz and Fz wafers was irradiated with 23 GeV protons, 200 MeV pions and reactor neutrons up to the equivalent fluences of PHI{sub eq}=3x10{sup 15}cm{sup -2}. The evolution of the full depletion voltage and the leakage current were monitored during short- and long-term annealing. At selected representative annealing steps, charge collection measurements were performed for all samples with LHC speed electronics. Measurements of full depletion voltage, leakage current and charge collection efficiency were compared for different irradiation particles and silicon materials.

  2. Influence of gravitational and vibrational convection on the heat- and mass transfer in the melt during crystal growing by Bridgman and floating zone methods

    Science.gov (United States)

    Fedorov, Oleg

    2016-07-01

    Space materials science is one of the priorities of different national and international space programs. The physical processes of heat and mass transfer in microgravity (including effect of g-jitter) is far from complete clarity, especially for important practical technology for producing crystals from the melt. The idea of the impact on crystallizing melt by low frequency vibration includes not only the possibility to suppress unwanted microaccelerations, but also to actively influence the structure of the crystallization front. This approach is one of the most effective ways to influence the quality of materials produced in flight conditions. The subject of this work is the effect of vibrations on the thermal and hydrodynamic processes during crystal growth using Bridgman and floating zone techniques, which have the greatest prospect of practical application in space. In the present approach we consider the gravitational convection, Marangoni convection, as well as the effect of vibration on the melt for some special cases. The results of simulation were compared with some experimental data obtained by the authors using a transparent model substance - succinonitrile (Bridgman method), and silicon (floating zone method). Substances used, process parameters and characteristics of the experimental units correspond the equipment developed for onboard research and serve as a basis for selecting optimum conditions vibration exposure as a factor affecting the solidification pattern. The direction of imposing vibrations coincides with the axis of the crystal, the frequency is presented by the harmonic law, and the force of gravity was varied by changing its absolute value. Mathematical model considered axisymmetric approximation of joint convective-conductive energy transfer in the system crystal - melt. Upon application of low-frequency oscillations of small amplitude along the axis of growing it was found the suppression of the secondary vortex flows near the

  3. Performance, Defect Behavior and Carrier Enhancement in Low Energy, Proton Irradiated p(+)nn(+) InP Solar Cells

    Science.gov (United States)

    Weinberg, I.; Rybicki, G. C.; Vargas-Aburto, C.; Jain, R. K.; Scheiman, D.

    1994-01-01

    InP p(+)nn(+) cells, processed by MOCVD, were irradiated by 0.2 MeV protons and their performance and defect behavior observed to a maximum fluence of 10(exp 13)/sq cm. Their radiation induced degradation, over this fluence range, was considerably+less than observed for similarly irradiated, diffused junction n p InP cells. Significant degradation occurred in both the cell's emitter and base regions the least degradation occurring in the depletion region. A significant increase in series resistance occurs at the highest fluenc.e. Two majority carrier defect levels, E7 and E10, are observed by DLTS with activation energies at (E(sub C) - 0.39)eV and (E(sub C) - 0.74)eV respectively. The relative concentration of these defects differs considerably from that observed after 1 MeV electron irradiation. An increased carrier concentration in the cell's n-region was observed at the highest proton fluence, the change in carrier concentration being insignificant at the lower fluences. In agreement with previous results, for 1 and 1.5 MeV electron irradiated InP p(+)n junctions, the defect level E10 is attributed to a complex between zinc, diffused into the n-region from the zinc doped emitter, and a radiation induced defect. The latter is assumed to be either a phosphorus vacancy or interstitial. The increased, or enhanced carrier concentration is attributed to this complex acting as a donor.

  4. Changes in luminescence emission induced by proton irradiation: InGaAs/GaAs quantum wells and quantum dots

    Science.gov (United States)

    Leon, R.; Swift, G. M.; Magness, B.; Taylor, W. A.; Tang, Y. S.; Wang, K. L.; Dowd, P.; Zhang, Y. H.

    2000-01-01

    The photoluminescence emission from InGaAs/GaAs quantum-well and quantum-dot (QD) structures are compared after controlled irradiation with 1.5 MeV proton fluxes. Results presented here show a significant enhancement in radiation tolerance with three-dimensional quantum confinement.

  5. Establishment and Study of Dose Fields for the Irradiation of Experimental Animals with High-Energy Protons; Creation et Etude de Champs de Rayonnements pour l'Irradiation d'Animaux de Grande Taille par des Protons de Haute Energie; Sozdanie i issledovanie doznykh polej dlya oblucheniya ehksperimental'nykh zhivotnykh protonami bol'shoj ehnergii; Produccion y Estudio de Campos Radia Torios para la Exposicion de Animales de Laboratorio a Protones de Elevada Energia

    Energy Technology Data Exchange (ETDEWEB)

    Afanas' ev, V. P.; Keirim-Markus, I. B.; Kuznecova, S. S.; Litvinova, Je. G.; Sokolova, I. K.; Stukina, L. E.

    1964-03-15

    Present-day accelerators make it possible to obtain beams of protons which have adequate intensity but are not suitable for the general irradiation of large experimental animals. Using the synchrotron of the Joint Institute of Nuclear Research it has been shown that with the aid of absorbers it is possible to expand a proton beam to the dimensions required, without introducing the accompanying radiations. Dose fields, uniform within {+-} 10%, in which primary protons constitute between 99 and 88% of the tissue dose, were obtained for irradiation of dogs with protons of energy 510, 250 and 120 MeV. The tissue doses and the radiation composition were studied in a dog phantom. Irradiation conditions for ensuring uniform radiation of the dog's body are proposed. Various questions of high-energy proton dosimetry are discussed, and the use of different types of dosimeter are considered in this connection. The paper also describes a method of determining the contribution of cascade neutrons to the proton flux, using activation detectors. (author) [French] Les accelerateurs actuels permettent d'obtenir des faisceaux de protons d'une intensite suffisante mais impropres a l'irradiation generale de grands animaux d'experience. A l'aide du synchrocyclotron OIAI, on a montre que le recours aux absorbants permet d'elargir le faisceau de protons jusqu'aux dimensions voulues sans y introduire de rayonnements secondaires. Pour irradier des chiens par des protons de 510, 250 et 120 MeV, on a pu ainsi realiser des champs de rayonnements uniformes a {+-}10% pres, dans lesquels les protons primaires constituaient 99 a 88% de la dose tissulaire. Les auteurs ont etudie des doses tissulaires et la composition du rayonnement a l'interieur d'un fantome de chien. Ils indiquent dans quelles conditions on assure une irradiation uniforme du corps de l'animal. Les auteurs examinent plusieurs questions relatives a la dosimetrie des neutrons de grande energie. Ils justifient l'emploide divers

  6. Proton irradiation effects on deep level states in Mg-doped p-type GaN grown by ammonia-based molecular beam epitaxy

    Science.gov (United States)

    Zhang, Z.; Arehart, A. R.; Kyle, E. C. H.; Chen, J.; Zhang, E. X.; Fleetwood, D. M.; Schrimpf, R. D.; Speck, J. S.; Ringel, S. A.

    2015-01-01

    The impact of proton irradiation on the deep level states throughout the Mg-doped p-type GaN bandgap is investigated using deep level transient and optical spectroscopies. Exposure to 1.8 MeV protons of 1 × 1013 cm-2 and 3 × 1013 cm-2 fluences not only introduces a trap with an EV + 1.02 eV activation energy but also brings monotonic increases in concentration for as-grown deep states at EV + 0.48 eV, EV + 2.42 eV, EV + 3.00 eV, and EV + 3.28 eV. The non-uniform sensitivities for individual states suggest different physical sources and/or defect generation mechanisms. Comparing with prior theoretical calculations reveals that several traps are consistent with associations to nitrogen vacancy, nitrogen interstitial, and gallium vacancy origins, and thus are likely generated through displacing nitrogen and gallium atoms from the crystal lattice in proton irradiation environment.

  7. Hypofractionated high-energy proton-beam irradiation is an alternative treatment for WHO grade I meningiomas.

    Science.gov (United States)

    Vlachogiannis, Pavlos; Gudjonsson, Olafur; Montelius, Anders; Grusell, Erik; Isacsson, Ulf; Nilsson, Kristina; Blomquist, Erik

    2017-12-01

    Radiation treatment is commonly employed in the treatment of meningiomas. The aim of this study was to evaluate the effectiveness and safety of hypofractionated high-energy proton therapy as adjuvant or primary treatment for WHO grade I meningiomas. A total of 170 patients who received irradiation with protons for grade I meningiomas between 1994 and 2007 were included in the study. The majority of the tumours were located at the skull base (n = 155). Eighty-four patients were treated post subtotal resection, 42 at tumour relapse and 44 with upfront radiotherapy after diagnosis based on the typical radiological image. Irradiation was given in a hypofractionated fashion (3-8 fractions, usually 5 or 6 Gy) with a mean dose of 21.9 Gy (range, 14-46 Gy). All patients were planned for follow-up with clinical controls and magnetic resonance imaging scans at 6 months and 1, 2, 3, 5, 7 and 10 years after treatment. The median follow-up time was 84 months. Age, gender, tumour location, Simpson resection grade and target volume were assessed as possible prognostic factors for post-irradiation tumour progression and radiation related complications. The actuarial 5- and 10-year progression-free survival rates were 93% and 85% respectively. Overall mortality rate was 13.5%, while disease-specific mortality was 1.7% (3/170 patients). Older patients and patients with tumours located in the middle cranial fossa had a lower risk for tumour progression. Radiation-related complications were seen in 16 patients (9.4%), with pituitary insufficiency being the most common. Tumour location in the anterior cranial fossa was the only factor that significantly increased the risk of complications. Hypofractionated proton-beam radiation therapy may be used particularly in the treatment of larger World Health Organisation grade I meningiomas not amenable to total surgical resection. Treatment is associated with high rates of long-term tumour growth control and acceptable risk for

  8. Ipsilateral Floating Hip and Floating Knee – A Rare Entity

    Directory of Open Access Journals (Sweden)

    Yashavantha Kumar

    2013-04-01

    Full Text Available Introduction: Ipsilateral floating hip and floating knee are very rare injuries. These injuries so uncommon that only three cases of similar kind have been reported. These injuries are due to high velocity injuries following motor vehicle accidents. Management of such complex injuries is a challenging task even in experienced hands as there are no standard treatment guidelines for such fractures. Case Report: We hereby report a 20 yr old male who sustained ipsilateral floating hip and ipsilateral floating knee injuries following motor vehicle accident. Patient was stabilized initially and later taken up for surgery. Patient was treated with interlocking nail for femur and tibia in the same sitting whereas acetabulam fracture was managed conservatively. At five months all the fractures united well with restoration of good range of motion in both hip and knee. Conclusion: Ipsilateral floating knee and floating hip are very rare injuries seen following high velocity motor vehicle accidents. There are no standard guidelines for treatment of those fractures as only a few cases of similar kind have been reported in literature. Early fixation and aggressive mobilization ensures fracture union and fewer complications. Keywords: Floating hip, Floating Knee, Ipsilateral.

  9. Volume-Dependent Expression of In-Field and Out-of-Field Effects in the Proton-Irradiated Rat Lung

    NARCIS (Netherlands)

    Coppes, Robert P.; Muijs, Christina T.; Faber, Hette; Gross, Sascha; Schippers, Jacobus M.; Brandenburg, Sytze; Langendijk, Johannes A.; van Luijk, Peter

    2011-01-01

    Purpose: To investigate whether occurance of early radiation effects in lung tissue depends on local close only. Methods and Materials: Twenty-five percent. 50%, 66%, 88%, or 100% of the rat lung was irradiated using single fractions of 150-MeV protons. For all volumes, in-field and out-of-field

  10. Neutron irradiation facility and its characteristics

    International Nuclear Information System (INIS)

    Oyama, Yukio; Noda, Kenji

    1995-01-01

    A neutron irradiation facility utilizing spallation reactions with high energy protons is conceived as one of the facilities in 'Proton Engineering center (PEC)' proposed at JAERI. Characteristics of neutron irradiation field of the facility for material irradiation studies are described in terms of material damage parameters, influence of the pulse irradiation, irradiation environments other than neutronics features, etc., comparing with the other sorts of neutron irradiation facilities. Some perspectives for materials irradiation studies using PEC are presented. (author)

  11. Proton implantation effect on (SUS-316) stainless steel

    International Nuclear Information System (INIS)

    Das, A.K.; Ishigami, R.; Kamal, I.

    2015-01-01

    Microstructural damage and nano hardness of the industrial grade stainless steel (SUS-316) have been studied under proton (H + ) implanted condition applying different doses at room temperature. The implantation scheme such as proton energy, fluence, irradiation time, and penetration depth in the target materials were estimated by Monte Carlo Simulation Code SRIM-2008. In the simulation, the parameters were chosen in such a way that the damage density (displacement per atom or dpa) would be uniform up to certain depth from the surface. X-ray diffraction study of the annealed samples prior to the proton implantation showed the austenitic fcc structure and no significant change was observed after proton implantation in it. Microstructural observation made by Scanning Transmission Electron Microscopy (STEM) revealed that 1 dpa of proton-irradiation induced the structural damage extended up to 1 μm depth from the surface. The nano hardness study showed that the hardness level of the irradiated samples increased monotonically with the irradiation doses. Proton dose of 1 dpa caused 65% increment of hardness level on average in case of uniformly irradiated samples. It was realized that the increment of hardness was a consequence of microstructural damages caused by the formation of interstitial dislocation loops in the sample matrix keeping the lattice structure unaffected

  12. Artisanal fishing net float loss and a proposal for a float design solution

    Directory of Open Access Journals (Sweden)

    Paulo de Tarso Chaves

    2016-03-01

    Full Text Available Abstract Plastic floats from fishing nets are commonly found washed up on beaches in southern Brazil. They are usually broken and show signs of having been repaired. Characteristics of floats and interviews with fishermen suggest two main causes of float loss. First, collisions between active gear, bottom trawl nets for shrimp, and passive gear, drift nets for fish, destroy nets and release fragments of them, including floats. Second, the difficulty with which floats are inserted on the float rope of the nets when they are used near the surface. Floats are inserted to replace damaged or lost floats, or they may be removed if it is desired that the nets be used in deeper waters. Floats may thus be poorly fixed to the cables and lost. Here a new float design that offers greater safety in use and for the replacement of floats is described and tested.

  13. Detailed Analysis of Apoptosis and Delayed Luminescence of Human Leukemia Jurkat T Cells after Proton Irradiation and Treatments with Oxidant Agents and Flavonoids

    Directory of Open Access Journals (Sweden)

    Irina Baran

    2012-01-01

    Full Text Available Following previous work, we investigated in more detail the relationship between apoptosis and delayed luminescence (DL in human leukemia Jurkat T cells under a wide variety of treatments. We used menadione and hydrogen peroxide to induce oxidative stress and two flavonoids, quercetin, and epigallocatechin gallate, applied alone or in combination with menadione or H2O2. 62 MeV proton beams were used to irradiate cells under a uniform dose of 2 or 10 Gy, respectively. We assessed apoptosis, cell cycle distributions, and DL. Menadione, H2O2 and quercetin were potent inducers of apoptosis and DL inhibitors. Quercetin decreased clonogenic survival and the NAD(PH level in a dose-dependent manner. Proton irradiation with 2 Gy but not 10 Gy increased the apoptotic rate. However, both doses induced a substantial G2/M arrest. Quercetin reduced apoptosis and prolonged the G2/M arrest induced by radiation. DL spectroscopy indicated that proton irradiation disrupted the electron flow within Complex I of the mitochondrial respiratory chain, thus explaining the massive necrosis induced by 10 Gy of protons and also suggested an equivalent action of menadione and quercetin at the level of the Fe/S center N2, which may be mediated by their binding to a common site within Complex I, probably the rotenone-binding site.

  14. Annealing enhancement effect by light illumination on proton irradiated Cu(In, Ga)Se2 thin-film solar cells

    International Nuclear Information System (INIS)

    Kawakita, Shirou; Imaizumi, Mitsuru; Matsuda, Sumio; Yamaguchi, Masafumi; Kushiya, Katsumi; Ohshima, Takeshi; Itoh, Hisayoshi

    2002-01-01

    In this paper, we investigated the high radiation tolerance of copper indium gallium di-selenide (CIGS) thin-film solar cells by conducting in situ measurements of short circuit current and open circuit voltage of CIGS thin-film solar cells during and after proton irradiation under short circuit condition. We found that the annealing rate of proton-induced defects in CIGS thin-film solar cells under light illumination with an AM0 solar simulator is higher than that under dark conditions. The activation energy of proton-induced defects in the CIGS thin-film solar cells with (without) light illumination is 0.80 eV (0.92 eV), which implies on enhanced defect annealing rate in CIGS thin-film solar cells due to minority-carrier injection. (author)

  15. SU-F-J-56: The Connection Between Cherenkov Light Emission and Radiation Absorbed Dose in Proton Irradiated Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Darafsheh, A; Kassaee, A; Finlay, J [University of Pennsylvania, Philadelphia, PA (United States); Taleei, R [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Range verification in proton therapy is of great importance. Cherenkov light follows the photon and electron energy deposition in water phantom. The purpose of this study is to investigate the connection between Cherenkov light generation and radiation absorbed dose in a water phantom irradiated with proton beams. Methods: Monte Carlo simulation was performed by employing FLUKA Monte Carlo code to stochastically simulate radiation transport, ionizing radiation dose deposition, and Cherenkov radiation in water phantoms. The simulations were performed for proton beams with energies in the range 50–600 MeV to cover a wide range of proton energies. Results: The mechanism of Cherenkov light production depends on the initial energy of protons. For proton energy with 50–400 MeV energy that is below the threshold (∼483 MeV in water) for Cherenkov light production directly from incident protons, Cherenkov light is produced mainly from the secondary electrons liberated as a result of columbic interactions with the incident protons. For proton beams with energy above 500 MeV, in the initial depth that incident protons have higher energy than the Cherenkov light production threshold, the light has higher intensity. As the slowing down process results in lower energy protons in larger depths in the water phantom, there is a knee point in the Cherenkov light curve vs. depth due to switching the Cherenkov light production mechanism from primary protons to secondary electrons. At the end of the depth dose curve the Cherenkov light intensity does not follow the dose peak because of the lack of high energy protons to produce Cherenkov light either directly or through secondary electrons. Conclusion: In contrast to photon and electron beams, Cherenkov light generation induced by proton beams does not follow the proton energy deposition specially close to the end of the proton range near the Bragg peak.

  16. A floating water bridge produces water with excess charge

    International Nuclear Information System (INIS)

    Fuchs, Elmar C; Sammer, Martina; Wexler, Adam D; Kuntke, Philipp; Woisetschläger, Jakob

    2016-01-01

    Excess positive and negative Bjerrum-defect like charge (protonic and ‘aterprotonic’, from ancient Greek ατερ, ‘without’) in anolyte and catholyte of high voltage electrolysis of highly pure water was found during the so-called ‘floating water bridge’ experiment. The floating water bridge is a special case of an electrohydrodynamic liquid bridge and constitutes an intriguing phenomenon that occurs when a high potential difference (∼kV cm −1 ) is applied between two beakers of water. To obtain such results impedance spectroscopy was used. This measurement technique allows the depiction and simulation of complex aqueous systems as simple electric circuits. In the present work we show that there is an additional small contribution from the difference in conductivity between anolyte and catholyte which cannot be measured with a conductivity meter, but is clearly visible in an impedance spectrum. (paper)

  17. Kinetics of cluster-related defects in silicon sensors irradiated with monoenergetic electrons

    Science.gov (United States)

    Radu, R.; Pintilie, I.; Makarenko, L. F.; Fretwurst, E.; Lindstroem, G.

    2018-04-01

    This work focuses on the kinetic mechanisms responsible for the annealing behavior of radiation cluster-related defects with impact on the electrical performance of silicon sensors. Such sensors were manufactured on high resistivity n-type standard float-zone (STFZ) and oxygen enriched float-zone (DOFZ) material and had been irradiated with mono-energetic electrons of 3.5 MeV energy and fluences of 3 × 1014 cm-2 and 6 × 1014 cm-2. After irradiation, the samples were subjected either to isochronal or isothermal heat treatments in the temperature range from 80 °C to 300 °C. The specific investigated defects are a group of three deep acceptors [H(116 K), H(140 K), and H(152 K)] with energy levels in the lower half of the band gap and a shallow donor E(30 K) with a level at 0.1 eV below the conduction band. The stability and kinetics of these defects at high temperatures are discussed on the basis of the extracted activation energies and frequency factors. The annealing of the H defects takes place similarly in both types of materials, suggesting a migration rather than a dissociation mechanism. On the contrary, the E(30 K) defect shows a very different annealing behavior, being stable in STFZ even at 300 °C, but annealing-out quickly in DOFZ material at temperatures higher than 200 °C , with a high frequency factor of the order of 1013 s-1. Such a behavior rules out a dissociation process, and the different annealing behavior is suggested to be related to a bistable behavior of the defect.

  18. Comparison Between In-Beam and Offline Positron Emission Tomography Imaging of Proton and Carbon Ion Therapeutic Irradiation at Synchrotron- and Cyclotron-Based Facilities

    International Nuclear Information System (INIS)

    Parodi, Katia; Bortfeld, Thomas; Haberer, Thomas

    2008-01-01

    Purpose: The benefit of using dedicated in-beam positron emission tomography (PET) detectors in the treatment room instead of commercial tomographs nearby is an open question. This work quantitatively compares the measurable signal for in-beam and offline PET imaging, taking into account realistic acquisition strategies at different ion beam facilities. Both scenarios of pulsed and continuous irradiation from synchrotron and cyclotron accelerators are considered, because of their widespread use in most carbon ion and proton therapy centers. Methods and Materials: A mathematical framework is introduced to compare the time-dependent amount and spatial distribution of decays from irradiation-induced isotope production. The latter is calculated with Monte Carlo techniques for real proton treatments of head-and-neck and paraspinal tumors. Extrapolation to carbon ion irradiation is based on results of previous phantom experiments. Biologic clearance is modeled taking into account available data from previous animal and clinical studies. Results: Ratios between the amount of physical decays available for in-beam and offline detection range from 40% to 60% for cyclotron-based facilities, to 65% to 110% (carbon ions) and 94% to 166% (protons) at synchrotron-based facilities, and increase when including biologic clearance. Spatial distributions of decays during irradiation exhibit better correlation with the dose delivery and reduced influence of biologic processes. Conclusions: In-beam imaging can be advantageous for synchrotron-based facilities, provided that efficient PET systems enabling detection of isotope decays during beam extraction are implemented. For very short (<2 min) irradiation times at cyclotron-based facilities, a few minutes of acquisition time after the end of irradiation are needed for counting statistics, thus affecting patient throughput

  19. Methods of thallium-201 preparation from proton irradiated thallium targets

    International Nuclear Information System (INIS)

    Kozlova, M.D.; Sevast'yanova, A.S.; Malinin, A.B.; Kurenkov, N.V.

    1989-01-01

    Two methods of thallium-201 preparation from Tl-targets irradiated by protons: oxidation-extraction (1) and extraction (2) - are developed. At first radioactive lead is separated from the target material - thallium macroquantities during ∼32 hours, then thallium-201 was separated from residual activity of lead radioisotopes and transformed it into the necessary chemical formula. The 1st and 2nd methods differ from each other by the 1st stage of target retreatment; only extraction was used to separate radioactive lead in the 2nd method. The target was solved in H 2 SO 4 . The 1st method permits to separate thallium-201 with chemical yield not less than 90 %, the 2nd one - higher than 95 %. Volumetric activity of thallium-201 prepared is more than 55 MBq/ml. 5 refs

  20. Proton irradiation effects on tensile and bend-fatigue properties of welded F82H specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saito, S., E-mail: saito.shigeru@jaea.go.j [JAEA Tokai, J-PARC Center, 2-4 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Kikuchi, K.; Hamaguchi, D. [JAEA Tokai, J-PARC Center, 2-4 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Usami, K.; Ishikawa, A.; Nishino, Y.; Endo, S. [JAEA Tokai, Department of Hot Laboratories, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Kawai, M. [KEK, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Dai, Y. [PSI, Spallation Source Division, 5232 Villigen PSI (Switzerland)

    2010-03-15

    In several institutes, research and development for an accelerator-driven transmutation system (ADS) have been progressed. Ferritic/martensitic (FM) steels are the candidate materials for the beam window of ADS. To evaluate of the mechanical properties of the irradiated materials, the post irradiation examination (PIE) work of the SINQ (Swiss spallation neutron source) target irradiation program (STIP) specimens was carried out at JAEA. In present study, the results of PIE on FM steel F82H and its welded joint have been reported. The present irradiation conditions of the specimens were as follows: proton energy was 580 MeV. Irradiation temperatures were ranged from 130 to 380 deg. C, and displacement damage level was ranged from 5.7 to 11.8 dpa. The results of tensile tests performed at 22 deg. C indicated that the irradiation hardening occurred with increasing the displacement damage up to 10.1 dpa at 320 deg. C irradiation. At higher dose (11.8 dpa) and higher temperature (380 deg. C), irradiation hardening was observed, but degradation of ductility was relaxed in F82H welded joint. In present study, all specimens kept its ductility after irradiation and fractured in ductile manner. The results on bend-fatigue tests showed that the fatigue life (N{sub f}) of F82H base metal irradiated up to 6.3 dpa was almost the same with that of unirradiated specimens. The N{sub f} of the specimens irradiated up to 9.1 dpa was smaller than that of unirradiated specimens. Though the number of specimen was limited, the N{sub f} of F82H EB (15 mm) and EB (3.3 mm) welded joints seemed to increase after irradiation and the fracture surfaces of the specimens showed transgranular morphology. While F82H TIG welded specimens were not fractured by 10{sup 7} cycles.

  1. Preparation of carrier-free 67Ga, by irradiation of natural zinc with protons

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da; Barbosa, M.F. de.

    1983-02-01

    A method for the preparation of carrier-free 67 Ga is described. Natural zinc plates were irradiated with protons. After a decay period of four days, the irradiated targets were dissolved in concentrated hydrochloric acid and the solution percolated through a glass column containing a cationic resin. 67 Ga was eluted with 3,5 N HCl; the eluted solution was evaporated to dryness, taken up in 3,8% sodium citrate solution and sterilized. Sterility tests were carried out according to the requirements of the U.S. Pharmacopeia. Chemical purity of 67 Ga citrate was determined by spot tests and by atomic absorption spectrophotometry. The radioactive purity was verified by gamma spectrometry. The product was endovenously injected into Wistar rats with experimental abcesses, and in a patient with adrenal neuroblastoma. The results shown a high accumulation of 67 Ga in soft tissue tumors. (Author) [pt

  2. Use of primary cell cultures to measure the late effects in the skins of rhesus monkeys irradiated with protons

    Science.gov (United States)

    Cox, A. B.; Wood, D. H.; Lett, J. T.

    Previous pilot investigations of the uses of primary cell cultures to study late damage in stem cells of the skin of the New Zealand white (NZW) rabbit and the rhesus monkey /1-3/, have been extended to individual monkeys exposed to 55 MeV protons. Protons of this energy have a larger range in tissue of (~2.6 cm) than the 32 MeV protons (~0.9 cm) to which the animals in our earlier studies had been exposed. Although the primary emphases in the current studies were improvement and simplification in the techniques and logistics of transportation of biopsies to a central analytical facility, comparison of the quantitative measurements obtained thus far for survival of stem cells in the skins from animals irradiated 21 years ago reveals that the effects of both proton energies are similar.

  3. Thermal conductivity profile determination in proton-irradiated ZrC by spatial and frequency scanning thermal wave methods

    International Nuclear Information System (INIS)

    Jensen, C.; Chirtoc, M.; Horny, N.; Antoniow, J. S.; Pron, H.; Ban, H.

    2013-01-01

    Using complementary thermal wave methods, the irradiation damaged region of zirconium carbide (ZrC) is characterized by quantifiably profiling the thermophysical property degradation. The ZrC sample was irradiated by a 2.6 MeV proton beam at 600 °C to a dose of 1.75 displacements per atom. Spatial scanning techniques including scanning thermal microscopy (SThM), lock-in infrared thermography (lock-in IRT), and photothermal radiometry (PTR) were used to directly map the in-depth profile of thermal conductivity on a cross section of the ZrC sample. The advantages and limitations of each system are discussed and compared, finding consistent results from all techniques. SThM provides the best resolution finding a very uniform thermal conductivity envelope in the damaged region measuring ∼52 ± 2 μm deep. Frequency-based scanning PTR provides quantification of the thermal parameters of the sample using the SThM measured profile to provide validation of a heating model. Measured irradiated and virgin thermal conductivities are found to be 11.9 ± 0.5 W m −1 K −1 and 26.7 ±1 W m −1 K −1 , respectively. A thermal resistance evidenced in the frequency spectra of the PTR results was calculated to be (1.58 ± 0.1) × 10 −6 m 2 K W −1 . The measured thermal conductivity values compare well with the thermal conductivity extracted from the SThM calibrated signal and the spatially scanned PTR. Combined spatial and frequency scanning techniques are shown to provide a valuable, complementary combination for thermal property characterization of proton-irradiated ZrC. Such methodology could be useful for other studies of ion-irradiated materials

  4. Study of the iron corrosion at the interface of different media (water, air) submitted to protons irradiation; Etude de la corrosion du fer a l'interface de differents milieux (eau, air) soumis a l'irradiation de protons

    Energy Technology Data Exchange (ETDEWEB)

    Lapuerta, S

    2005-10-15

    During the deep geological disposal, stainless steel containers of the vitrified waste will be put in carbon steel overpacks. After the closing of the storage site, overpacks will be in contact with a humid air and a radioactive medium. After hundred years, overpacks could be in contact with water radiolysis in an anoxic medium. In this context, my PhD work is a fundamental study which is the understanding of the corrosion mechanisms of pure iron under proton irradiation. This corrosion is affected by the contact of iron with different atmospheres (air, nitrogen) and water. In the case of the atmospheric iron corrosion under irradiation, we have studied the influence of the proton beam flux. During this work, we have characterized the structure of the oxides formed at the iron surface. The structure formed does not correspond to iron oxides and hydroxides indexed. However, we have shown that the oxide structure is close to that of lepidocrocite and bernalite. Moreover, we have determined the oxygen diffusion coefficient in iron under irradiation and we have shown that the irradiation accelerates of 6 orders of magnitude the iron corrosion. In addition, the irradiations which were realized in different gas have put in evidence the negligible role of nitrates, and the importance of the O{sub 2}/H{sub 2}O coupling on the iron corrosion. Finally, we have shown the influence of the relative humidity, the maximum of the corrosion being observed for a relative humidity close to 45%. In the case of the iron corrosion in aqueous media under irradiation, the influence of the oxygen dissolved in water has been studied using a surface marker. We have put in evidence that the corrosion is twice more significant in aerated medium than in deaerated medium. Moreover, the influence of radicals has been shown. An irradiated sample is more corroded than a sample put in contact with a H{sub 2}O{sub 2} solution. Finally, the follow-up of the iron potential under irradiation have shown

  5. A proton irradiation test facility for space research in Ankara, Turkey

    Science.gov (United States)

    Gencer, Ayşenur; Yiǧitoǧlu, Merve; Bilge Demirköz, Melahat; Efthymiopoulos, Ilias

    2016-07-01

    Space radiation often affects the electronic components' performance during the mission duration. In order to ensure reliable performance, the components must be tested to at least the expected dose that will be received in space, before the mission. Accelerator facilities are widely used for such irradiation tests around the world. Turkish Atomic Energy Authority (TAEA) has a 15MeV to 30MeV variable proton cyclotron in Ankara and the facility's main purpose is to produce radioisotopes in three different rooms for different target systems. There is also an R&D room which can be used for research purposes. This paper will detail the design and current state of the construction of a beamline to perform Single Event Effect (SEE) tests in Ankara for the first time. ESA ESCC No.25100 Standard Single Event Effect Test Method and Guidelines is being considered for these SEE tests. The proton beam kinetic energy must be between 20MeV and 200MeV according to the standard. While the proton energy is suitable for SEE tests, the beam size must be 15.40cm x 21.55cm and the flux must be between 10 ^{5} p/cm ^{2}/s to at least 10 ^{8} p/cm ^{2}/s according to the standard. The beam size at the entrance of the R&D room is mm-sized and the current is variable between 10μA and 1.2mA. Therefore, a defocusing beam line has been designed to enlarge the beam size and reduce the flux value. The beam line has quadrupole magnets to enlarge the beam size and the collimators and scattering foils are used for flux reduction. This facility will provide proton fluxes between 10 ^{7} p/cm ^{2}/s and 10 ^{10} p/cm ^{2}/s for the area defined in the standard when completed. Also for testing solar cells developed for space, the proton beam energy will be lowered below 10MeV. This project has been funded by Ministry of Development in Turkey and the beam line construction will finish in two years and SEE tests will be performed for the first time in Turkey.

  6. Effect of analytical proton beam irradiation on lead-white pigments, characterized by EPR spectroscopy

    Science.gov (United States)

    Gourier, Didier; Binet, Laurent; Gonzalez, Victor; Vezin, Hervé; Touati, Nadia; Calligaro, Thomas

    2018-01-01

    Analytical techniques using proton beams with energy in the MeV range are commonly used to study archeological artefact and artistic objects. However ion beams can induce alteration of fragile materials, which is notably the case of easel paintings, limiting the use of these techniques. We used continuous wave EPR and pulse EPR spectroscopy to reveal the effect of 3 MeV proton irradiation on lead carbonates, which were extensively employed as white pigments from the antiquity to the 20th century. Two kinds of paramagnetic centers were identified in cerussite (PbCO3): the first one is CO3- radicals formed by hole trapping by CO32- ions, and the second one is NO32- radical resulting from electron trapping by NO3- impurities. Hydrocerussite (2PbCO3·Pb(OH)2) is the most darkened material under proton beam, however it exhibits no NO32- radicals and 20 times less CO3- radicals than cerussite. Consequently these paramagnetic centers are not directly responsible for the darkening of lead-white pigments. We proposed that their higher instability in hydrocerussite might be at the origin of the formation of color centers in this material.

  7. Evaluation of irradiation hardening of proton irradiated stainless steels by nanoindentation

    International Nuclear Information System (INIS)

    Yabuuchi, Kiyohiro; Kuribayashi, Yutaka; Nogami, Shuhei; Kasada, Ryuta; Hasegawa, Akira

    2014-01-01

    Ion irradiation experiments are useful for investigating irradiation damage. However, estimating the irradiation hardening of ion-irradiated materials is challenging because of the shallow damage induced region. Therefore, the purpose of this study is to prove usefulness of nanoindentation technique for estimation of irradiation hardening for ion-irradiated materials. SUS316L austenitic stainless steel was used and it was irradiated by 1 MeV H + ions to a nominal displacement damage of 0.1, 0.3, 1, and 8 dpa at 573 K. The irradiation hardness of the irradiated specimens were measured and analyzed by Nix–Gao model. The indentation size effect was observed in both unirradiated and irradiated specimens. The hardness of the irradiated specimens changed significantly at certain indentation depths. The depth at which the hardness varied indicated that the region deformed by the indenter had reached the boundary between the irradiated and unirradiated regions. The hardness of the irradiated region was proportional to the inverse of the indentation depth in the Nix–Gao plot. The bulk hardness of the irradiated region, H 0 , estimated by the Nix–Gao plot and Vickers hardness were found to be related to each other, and the relationship could be described by the equation, HV = 0.76H 0 . Thus, the nanoindentation technique demonstrated in this study is valuable for measuring irradiation hardening in ion-irradiated materials

  8. Strain hardening and plastic instability properties of austenitic stainless steels after proton and neutron irradiation

    International Nuclear Information System (INIS)

    Byun, T.S.; Farrell, K.; Lee, E.H.; Hunn, J.D.; Mansur, L.K.

    2001-01-01

    Strain hardening and plastic instability properties were analyzed for EC316LN, HTUPS316, and AL6XN austenitic stainless steels after combined 800 MeV proton and spallation neutron irradiation to doses up to 10.7 dpa. The steels retained good strain-hardening rates after irradiation, which resulted in significant uniform strains. It was found that the instability stress, the stress at the onset of necking, had little dependence on the irradiation dose. Tensile fracture stress and strain were calculated from the stress-strain curve data and were used to estimate fracture toughness using an existing model. The doses to plastic instability and fracture, the accumulated doses at which the yield stress reaches instability stress or fracture stress, were predicted by extrapolation of the yield stress, instability stress, and fracture stress to higher dose. The EC316LN alloy required the highest doses for plastic instability and fracture. Plastic deformation mechanisms are discussed in relation to the strain-hardening properties of the austenitic stainless steels

  9. Characterization of 150 $\\mu$m thick epitaxial silicon detectors from different producers after proton irradiation

    CERN Document Server

    Hoedlmoser, H; Haerkoenen, J; Kronberger, M; Trummer, J; Rodeghiero, P

    2007-01-01

    Epitaxial (EPI) silicon has recently been investigated for the development of radiation tolerant detectors for future high-luminosity HEP experiments. A study of 150 mm thick EPI silicon diodes irradiated with 24GeV=c protons up to a fluence of 3 1015 p=cm2 has been performed by means of Charge Collection Efficiency (CCE) measurements, investigations with the Transient Current Technique (TCT) and standard CV=IV characterizations. The aim of the work was to investigate the impact of radiation damage as well as the influence of the wafer processing on the material performance by comparing diodes from different manufacturers. The changes of CCE, full depletion voltage and leakage current as a function of fluence are reported. While the generation of leakage current due to irradiation is similar in all investigated series of detectors, a difference in the effective doping concentration can be observed after irradiation. In the CCE measurements an anomalous drop in performance was found even for diodes exposed to ...

  10. Effects of conventional high-voltage irradiation and proton irradiation as adjuncts to surgical measures in acromegaly with particular attention being given to the further course of illness with and without drug treatment

    International Nuclear Information System (INIS)

    Lutz, B.S.

    1986-01-01

    Comparisons of effectiveness and side-effect levels were carried out between conventional high-voltage irradiation and proton irradiation being used as adjunctive treatment in 56 patients suffering from acromegaly, whose STH levels had failed to return to normal (STH > 4.5 ng/ml) after surgery. For the evaluation of the results it was also of importance, if the patients were subjected to drug treatment or allowed to recover spontaneously during follow-up. The two therapeutic strategies were found to be equally potent. In both patient groups, the decreases in STH achieved over 4.5 to 5 years averaged 80%. Proton irradiation was associated with a higher rate of injuries to the anterior lobe of the pituitary, while the damage caused by conventional irradiation mostly was of a more severe nature (like generalised attacks). On an average, the STH levels of patients under treatment with dopamine agonists were reduced by approx. 67% within three years. In the group of patients receiving no further treatment in spite of sustained STH elevations (spontaneous recoveries) after surgery, 76.5% were found to have normal STH basal values by that time. (ECB) [de

  11. Taurine effect on cytogenetic lesions in the cornea of mice exposed to 9 Gev proton irradiation

    International Nuclear Information System (INIS)

    Vorozhtsova, S.V.; Yartsev, E.I.

    1989-01-01

    Possibilities of preventive measures and treatment of cytogenetic injuries in the mice cornea, subjected to proton irradiation at 9 Gev were studied. Taurine containing solution (TCS) was used as a radiomodifying agent. It is shown that TCS application enables to decrease aberrant mitoses level in cornea epithelium cells of mice. Antiactinic effect of the above agent is determined by its considerable action on mitotic delay

  12. High and Low Energy Proton Radiation Damage in p/n InP MOCVD Solar Cells

    Science.gov (United States)

    Rybicki, George; Weinberg, Irv; Scheiman, Dave; Vargas-Aburto, Carlos; Uribe, Roberto

    1995-01-01

    InP p(+)/n/n(+) solar cells, fabricated by metal organic chemical vapor deposition, (MOCVD) were irradiated with 0.2 MeV and 10 MeV protons to a fluence of 10(exp 13)/sq cm. The power output degradation, IV behavior, carrier concentration and defect concentration were observed at intermediate points throughout the irradiations. The 0.2 MeV proton-irradiated solar cells suffered much greater and more rapid degradation in power output than those irradiated with 10 MeV protons. The efficiency losses were accompanied by larger increases in the recombination currents in the 0.2 MeV proton-irradiated solar cells. The low energy proton irradiations also had a larger impact on the series resistance of the solar cells. Despite the radiation induced damage, the carrier concentration in the base of the solar cells showed no reduction after 10 MeV or 0.2 MeV proton irradiations and even increased during irradiation with 0.2 MeV protons. In a deep level transient spectroscopy (DLTS) study of the irradiated samples, the minority carrier defects H4 and H5 at E(sub v) + 0.33 and E(sub v) + 0.52 eV and the majority carrier defects E7 and El0 at E(sub c) - 0.39 and E(sub c) - 0.74 eV, were observed. The defect introduction rates for the 0.2 MeV proton irradiations were about 20 times higher than for the 10 MeV proton irradiations. The defect El0, observed here after irradiation, has been shown to act as a donor in irradiated n-type InP and may be responsible for obscuring carrier removal. The results of this study are consistent with the much greater damage produced by low energy protons whose limited range causes them to stop in the active region of the solar cell.

  13. Testing the Tester: Lessons Learned During the Testing of a State-of-the-Art Commercial 14nm Processor Under Proton Irradiation

    Science.gov (United States)

    Szabo, Carl M., Jr.; Duncan, Adam R.; Label, Kenneth A.

    2017-01-01

    Testing of an Intel 14nm desktop processor was conducted under proton irradiation. We share lessons learned, demonstrating that complex devices beget further complex challenges requiring practical and theoretical investigative expertise to solve.

  14. Investigation of the effects of head irradiation with gamma rays and protons on startle and pre-pulse inhibition behavior in mice.

    Science.gov (United States)

    Haerich, Paul; Eggers, Cara; Pecaut, Michael J

    2012-05-01

    With the increased international emphasis on manned space exploration, there is a growing need to understand the impact of the spaceflight environment on health and behavior. One particularly important aspect of this environment is low-dose radiation. In the present studies, we first characterized the γ- and proton-irradiation dose effect on acoustic startle and pre-pulse inhibition behaviors in mice exposed to 0-5 Gy brain-localized irradiation, and assessed these effects 2 days later. Subsequently, we used 2 Gy to assess the time course of γ- and proton-radiation effects on startle reactivity 0-8 days after exposure. Exposures targeted the brain to minimize the impact of peripheral inflammation-induced sickness behavior. The effects of radiation on startle were subtle and acute. Radiation reduced the startle response at 2 and 5 Gy. Following a 2-Gy exposure, the response reached a minimum at the 2-day point. Proton and γ-ray exposures did not differ in their impact on startle. We found there were no effects of radiation on pre-pulse inhibition of the startle response.

  15. {sup 55}Co separation from proton irradiated metallic nickel

    Energy Technology Data Exchange (ETDEWEB)

    Valdovinos, H. F., E-mail: hvaldovinos@wisc.edu; Graves, S., E-mail: hvaldovinos@wisc.edu; Barnhart, T., E-mail: hvaldovinos@wisc.edu; Nickles, R. J., E-mail: hvaldovinos@wisc.edu [Department of Medical Physics, University of Wisconsin - Madison, Madison, WI (United States)

    2014-11-07

    {sup 55}Co with > 97% radionuclidic purity 24 hours after end of bombardment (EoB) was produced from the {sup 58}Ni(p,α) reaction using proton irradiations of 16 MeV on natural nickel. Two-hour irradiations with 25 μA on a 254 μm thick nickel foil generate 0.18 ± 0.01 GBq (n = 3) 24 hours after EoB. The separation of cobalt from the target material and other metallic contaminants present at trace levels is accomplished in HCl medium by two rounds of anion exchange chromatography (AG1-X8) using an automated module driven by a peristaltic pump. 80 ± 5 % (n = 3) of the activity generated at EoB is ready for labeling in 0.1 M HCl one hour after the start of separation. Using 99.999% pure Ni, the reactivity (decay corrected to EoB) with the bifunctional chelator (BFC) DOTA was 8.5 GBq/μmol; enough for radiolabeling BFC conjugated biomolecules at a nmol scale with > 90% yield. Using 99.9% pure Ni the reactivity with DOTA and NOTA was 0.19 +/− 0.09 GBq/μmol and 2.9 +/− 1.7 GBq/μmol (n = 2), respectively. Both cobalt complexes showed 100% in vitro stability in PBS and mouse serum over 41 hours at room temperature. MicroPET images of a miniature Derenzo phantom show excellent resolution where rods of 1.5 mm were separated by two times their diameter.

  16. Characterization of proton and neutron irradiated low resistivity p-on-n magnetic Czochralski ministrip sensors and diodes

    International Nuclear Information System (INIS)

    Pacifico, Nicola; Dolenc Kittelmann, Irena; Fahrer, Manuel; Moll, Michael; Militaru, Otilia

    2011-01-01

    Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements were performed on low resistivity (280Ωcm) n-bulk, p-readout magnetic Czochralski ministrip sensors and diodes. The detectors were irradiated with neutrons and 24 GeV/c protons up to a total NIEL equivalent fluence of 8×10 15 /cm 2 . The study was addressed to assess the radiation tolerance of the detectors up to fluences expected in the next generations of High Energy Physics experiments. The charge collection efficiency after irradiation was found to be much higher than for standard FZ silicon p-in-n sensors. The underlying physics of this remarkable result was investigated by performing Edge-TCT measurements on one of the neutron irradiated ministrip sensors to extract detailed informations about the field and efficiency profiles of the detector.

  17. A Method to Simulate the Observed Surface Properties of Proton Irradiated Silicon Strip Sensors

    CERN Document Server

    INSPIRE-00335524; Bhardwaj, A.; Dalal, R.; Eber, R.; Eichhorn, T.; Lalwani, K.; Messineo, A.; Printz, M.; Ranjan, K.

    2015-04-23

    During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense radiation environment than the present system was designed for. To upgrade the tracker to required performance level, extensive measurements and simulations studies have already been carried out. A defect model of Synopsys Sentaurus TCAD simulation package for the bulk properties of proton irradiated devices has been producing simulations closely matching with measurements of silicon strip detectors. However, the model does not provide expected behavior due to the fluence increased surface damage. The solution requires an approach that does not affect the accurate bulk properties produced by the proton model, but only adds to it the required radiation induced properties close to the surface. These include the observed position dependency of the strip detector's charge collec...

  18. Electrical characterization of FBK small-pitch 3D sensors after γ-ray, neutron and proton irradiations

    Science.gov (United States)

    Dalla Betta, G.-F.; Boscardin, M.; Hoeferkamp, M.; Mendicino, R.; Seidel, S.; Sultan, D. M. S.

    2017-11-01

    In view of applications in the tracking detectors at the High Luminosity LHC (HL-LHC), we have developed a new generation of 3D pixel sensors featuring small-pitch (50 × 50 or 25 × 100 μ m2) and thin active layer (~ 100 μ m). Owing to the very short inter-electrode distance (~ 30 μ m), charge trapping effects can be strongly mitigated, making these sensors extremely radiation hard. However, the downscaled sensor structure also lends itself to high electric fields as the bias voltage is increased, motivating investigation of leakage current increase in order to prevent premature electrical breakdown due to impact ionization. In order to assess the characteristics of heavily irradiated samples, using 3D diodes as test devices, we have carried out a dedicated campaign that included several irradiations (γ -rays, neutrons, and protons) at different facilities. In this paper, we report on the electrical characterization of a subset of the irradiated samples, also in comparison to their pre-irradiation properties. Results demonstrate that hadron irradiated devices can be safely operated at a voltage high enough to allow for full depletion (hence high efficiency) also at the maximum fluence foreseen at the HL-LHC.

  19. Spherical nanoindentation of proton irradiated 304 stainless steel: A comparison of small scale mechanical test techniques for measuring irradiation hardening

    Science.gov (United States)

    Weaver, Jordan S.; Pathak, Siddhartha; Reichardt, Ashley; Vo, Hi T.; Maloy, Stuart A.; Hosemann, Peter; Mara, Nathan A.

    2017-09-01

    Experimentally quantifying the mechanical effects of radiation damage in reactor materials is necessary for the development and qualification of new materials for improved performance and safety. This can be achieved in a high-throughput fashion through a combination of ion beam irradiation and small scale mechanical testing in contrast to the high cost and laborious nature of bulk testing of reactor irradiated samples. The current work focuses on using spherical nanoindentation stress-strain curves on unirradiated and proton irradiated (10 dpa at 360 °C) 304 stainless steel to quantify the mechanical effects of radiation damage. Spherical nanoindentation stress-strain measurements show a radiation-induced increase in indentation yield strength from 1.36 GPa to 2.72 GPa and a radiation-induced increase in indentation work hardening rate of 10 GPa-30 GPa. These measurements are critically compared against Berkovich nanohardness, micropillar compression, and micro-tension measurements on the same material and similar grain orientations. The ratio of irradiated to unirradiated yield strength increases by a similar factor of 2 when measured via spherical nanoindentation or Berkovich nanohardness testing. A comparison of spherical indentation stress-strain curves to uniaxial (micropillar and micro-tension) stress-strain curves was achieved using a simple scaling relationship which shows good agreement for the unirradiated condition and poor agreement in post-yield behavior for the irradiated condition. The disagreement between spherical nanoindentation and uniaxial stress-strain curves is likely due to the plastic instability that occurs during uniaxial tests but is absent during spherical nanoindentation tests.

  20. SU-E-T-266: Development of Evaluation System of Optimal Synchrotron Controlling Parameter for Spot Scanning Proton Therapy with Multiple Gate Irradiations in One Operation Cycle

    International Nuclear Information System (INIS)

    Yamada, T; Fujii, Y; Miyamoto, N; Matsuura, T; Takao, S; Matsuzaki, Y; Koyano, H; Shirato, H; Nihongi, H; Umezawa, M; Matsuda, K; Umegaki, K

    2015-01-01

    Purpose: We have developed a gated spot scanning proton beam therapy system with real-time tumor-tracking. This system has the ability of multiple-gated irradiation in a single synchrotron operation cycle controlling the wait-time for consecutive gate signals during a flat-top phase so that the decrease in irradiation efficiency induced by irregular variation of gate signal is reduced. Our previous studies have shown that a 200 ms wait-time is appropriate to increase the average irradiation efficiency, but the optimal wait-time can vary patient by patient and day by day. In this research, we have developed an evaluation system of the optimal wait-time in each irradiation based on the log data of the real-time-image gated proton beam therapy (RGPT) system. Methods: The developed system consists of logger for operation of RGPT system and software for evaluation of optimal wait-time. The logger records timing of gate on/off, timing and the dose of delivered beam spots, beam energy and timing of X-ray irradiation. The evaluation software calculates irradiation time in the case of different wait-time by simulating the multiple-gated irradiation operation using several timing information. Actual data preserved in the log data are used for gate on and off time, spot irradiation time, and time moving to the next spot. Design values are used for the acceleration and deceleration times. We applied this system to a patient treated with the RGPT system. Results: The evaluation system found the optimal wait-time of 390 ms that reduced the irradiation time by about 10 %. The irradiation time with actual wait-time used in treatment was reproduced with accuracy of 0.2 ms. Conclusion: For spot scanning proton therapy system with multiple-gated irradiation in one synchrotron operation cycle, an evaluation system of the optimal wait-time in each irradiation based on log data has been developed. Funding Support: Japan Society for the Promotion of Science (JSPS) through the FIRST

  1. Fabrication of Nonvolatile Memory Effects in High-k Dielectric Thin Films Using Electron Irradiation

    International Nuclear Information System (INIS)

    Park, Chanrock; Cho, Daehee; Kim, Jeongeun; Hwang, Jinha

    2010-01-01

    Electron Irradiation can be applied towards nano-floating gate memories which are recognized as one of the next-generation nonvolatile memory semiconductors. NFGMs can overcome the preexisting limitations encountered in Dynamic Random Access Memories and Flash memories with the excellent advantages, i. e. high-density information storage, high response speed, high compactness, etc. The traditional nano-floating gate memories are fabricated through multi-layered nano structures of the dissimilar materials where the charge-trapping portions are sandwiched into the high-k dielectrics. However, this work reports the unique nonvolatile responses in single-layered high-k dielectric thin films if irradiated with highly accelerated electron beams. The implications of the electron irradiation will be discussed towards high-performance nano-floating gate memories

  2. Optimal conditions for high current proton irradiations at the university of Wisconsin's ion beam laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wetteland, C. J.; Field, K. G.; Gerczak, T. J. [Materials Science Program, University of Wisconsin, Madison, WI 53706 (United States); Eiden, T. J.; Maier, B. R.; Albakri, O.; Sridharan, K.; Allen, T. R. [Department of Engineering Physics, University of Wisconsin, Madison, WI 53706 (United States)

    2013-04-19

    The National Electrostatics Corporation's (NEC) Toroidal Volume Ion Source (TORVIS) source is known for exceptionally high proton currents with minimal service downtime as compared to traditional sputter sources. It has been possible to obtain over 150{mu}A of proton current from the source, with over 70{mu}A on the target stage. However, beam fluxes above {approx}1 Multiplication-Sign 10{sup 17}/m2-s may have many undesirable effects, especially for insulators. This may include high temperature gradients at the surface, sputtering, surface discharge, cracking or even disintegration of the sample. A series of experiments were conducted to examine the role of high current fluxes in a suite of ceramics and insulating materials. Results will show the optimal proton irradiation conditions and target mounting strategies needed to minimize unwanted macro-scale damage, while developing a procedure for conducting preliminary radiation experiments.

  3. Growth, and magnetic study of Sm0.4Er0.6FeO3 single crystal grown by optical floating zone technique

    Science.gov (United States)

    Wu, Anhua; Zhao, Xiangyang; Man, Peiwen; Su, Liangbi; Kalashnikova, A. M.; Pisarev, R. V.

    2018-03-01

    Sm0.4Er0.6FeO3 single crystals were successfully grown by optical floating zone method; high quality samples with various orientations were manufactured. Based on these samples, Magnetic property of Sm0.4Er0.6FeO3 single crystals were investigated systemically by means of the temperature dependence of magnetization. It indicated that compositional variations not only alter the spin reorientation temperature, but also the compensation temperature of the orthoferrites. Unlike single rare earth orthoferrites, the reversal transition temperature point of Sm0.4Er0.6FeO3 increases as magnetic field increases, which is positive for designing novel spin switching or magnetic sensor device.

  4. Comments on Moessbauer-effect studies on 2-MeV proton-irradiated Nb3Sn

    International Nuclear Information System (INIS)

    Cox, D.E.; Sweedler, A.R.

    1979-01-01

    In a recent paper, Herber and Kalish have presented 119 Sn Moessbauer data for Nb 3 Sn irradiated by 2-MeV protons which they interpret in terms of a statistical distribution of site defects rather than interchange of Nb and Sn atoms. Further analysis of these data leads to the conclusion that they are in fact quite consistent with the presence of a substantial amount of radiation-induced site-exchange disorder. This is in agreement with the findings of a number of recent diffraction studies

  5. CCE measurements and annealing studies on proton-irradiated p-type MCz silicon diodes

    CERN Document Server

    Hoedlmoser, H; Köhler, M; Nordlund, H

    2007-01-01

    Magnetic Czochralski (MCz) silicon has recently been investigated for the development of radiation tolerant detectors for future high-luminosity HEP experiments. A study of p-type MCz Silicon diodes irradiated with protons up to a fluence of has been performed by means of Charge Collection Efficiency (CCE) measurements as well as standard CV/IV characterizations. The changes of CCE, full depletion voltage and leakage current as a function of fluence are reported. A subsequent annealing study of the irradiated detectors shows an increase in effective doping concentration and a decrease in the leakage current, whereas the CCE remains basically unchanged. Two different series of detectors have been compared differing in the implantation dose of p-spray isolation as well as effective doping concentration (Neff) of the p-type bulk presumably due to a difference in thermal donor (TD) activation during processing. The series with the higher concentration of TDs shows a delayed reverse annealing of Neff after irradia...

  6. Formation of rutile fasciculate zone induced by sunlight irradiation at room temperature and its hemocompatibility

    International Nuclear Information System (INIS)

    Zhang, Xuan-Hui; Zheng, Xiang; Cheng, Yuan; Li, Guo-Hua; Chen, Xiao-Ping; Zheng, Jian-Hui

    2013-01-01

    The fasciculate zone of phase pure rutile was fabricated under sunlight irradiation at room temperature, using titanium tetrachloride as a sole precursor. The crystal phase, morphology and microstructure, and optical absorption behavior of the samples were characterized by X-ray Diffraction, High-Resolution Transmission Electron Microscope (HRTEM) and UV–vis Diffuse Reflectance Spectra (DRS), respectively. XRD results show that the crystal phase of the sample is composed of rutile only, and a lattice distortion displays in the crystallite of the sample. HRTEM results show that the morphology of rutile particle is fasciculate zone constituted of nanoparticles with a diameter of 4–7 nm, and these particles grow one by one and step by step. The pattern of the selected area electron diffraction of the sample is Kikuchi type, which can be attributed to the predominant orientation growth of rutile nanoparticles along [001] induced by sunlight irradiation. DRS results show that the absorption threshold of the sample is 415 nm, corresponding to the band gap energy of 2.99 eV, which is lower than the band gap energy of rutile, 3.03 eV. Blood compatibility measurement shows that the sample has no remarkable effect on hemolytic and coagulation activity. The percent hemolysis of red blood cells is less than 5% even treated with a big dosage of the fasciculate rutile and under UV irradiation, and there are no obvious changes of plasma recalcification time after the rutile treatment. Thus, the novel structure of rutile fasciculate has low potential toxicity for blood and is hemocompatibility safe. Highlights: • A novel approach to fabricate the fasciculate zone of phase pure rutile • The fasciculate grows from a particle to nanorod and to fasciculate, step by step. • A preferred orientation growth induced by sunlight irradiation in the fasciculate • The rutile fasciculate is low toxicity for blood and is hemocompatibility safe

  7. The RaDIATE High-Energy Proton Materials Irradiation Experiment at the Brookhaven Linac Isotope Producer Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ammigan, Kavin; et al.

    2017-05-01

    The RaDIATE collaboration (Radiation Damage In Accelerator Target Environments) was founded in 2012 to bring together the high-energy accelerator target and nuclear materials communities to address the challenging issue of radiation damage effects in beam-intercepting materials. Success of current and future high intensity accelerator target facilities requires a fundamental understanding of these effects including measurement of materials property data. Toward this goal, the RaDIATE collaboration organized and carried out a materials irradiation run at the Brookhaven Linac Isotope Producer facility (BLIP). The experiment utilized a 181 MeV proton beam to irradiate several capsules, each containing many candidate material samples for various accelerator components. Materials included various grades/alloys of beryllium, graphite, silicon, iridium, titanium, TZM, CuCrZr, and aluminum. Attainable peak damage from an 8-week irradiation run ranges from 0.03 DPA (Be) to 7 DPA (Ir). Helium production is expected to range from 5 appm/DPA (Ir) to 3,000 appm/DPA (Be). The motivation, experimental parameters, as well as the post-irradiation examination plans of this experiment are described.

  8. Irradiation of tungsten with metallic diatomic molecular ions: atomic-resolution observations of depleted zones

    International Nuclear Information System (INIS)

    Pramanik, D.; Seidman, D.N.

    1982-08-01

    Direct evidence, on an atomic scale, is presented for the enhancement of damage production per projectile ion in diatomic metallic molecular ion (dimer) irradiations of tungsten as compared to monatomic metallic ion (monomer) irradiations. Irradiations were performed in situ at less than or equal to 10 K, in a field-ion microscope, employing 20 keV Ag + or W + monomer ions and the results are compared with 40 keV W 2 + or Ag 2 + dimer ion bombardments; the average energy per ion was 20 keV. First, in the near-surface region the depleted zones produced by the W 2 + dimer ions give rise to void-like contrast effects. The W + monomer ions do not produce this void-like damage. The existence of voids was explained employing a nucleation and diffusion-limited growth model which suggests that the growth can occur on a time scale -9 s, if the effective diffusivity of an atom in the fully-developed collision cascade is > 3 x 10 -4 cm 2 s -1 . Second, by counting the number of vacancies in individual depleted zones, produced by the different ions, it was demonstrated that the number of vacancies produced per incoming ion of the dimer is 1.55 times greater than the number of vacancies produced per monomer ion

  9. Proton therapy of hypophyseal adenomas

    International Nuclear Information System (INIS)

    Mirakova, E.I.; Kirpatovskaya, L.E.; Lyass, F.M.; Snigireva, R.Ya.; Krymskij, V.A.; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Ehksperimental'noj Ehndokrinologii i Khimii Gormonov)

    1983-01-01

    The authors present the results of proton therapy in 59 patients with different hypophyseal adenomas. The period of observation lasted from 6 mos. to 5 yrs. Irradiation was done using a multifield-convergent method and a proton beam of the ITEF synchrotron. The beam energy was 200 MeV, the beam diameter 7-15 mm. Radiation response and immediate results were evaluated for all the patients. The least favorable results were noted in the patients with prolactinomas, for which, in addition to irradiation, parlodel therapy is needed. No marked radiation reactions, neurological complications and manifestations of hypopituitarism were observed with the chosen doses and schemes of irradiation

  10. On the position of local levels of defects in proton-irradiated Pb1-xSnxTe alloys

    International Nuclear Information System (INIS)

    Brandt, N.B.; Gas'kov, A.M.; Ladygin, E.A.; Skipetrov, E.P.; Khorosh, A.G.

    1989-01-01

    Effect of fast proton irradiation (T≅300 K, E=200 keV, F≤2x10 14 cm -2 ) on electrophysical properties of thin layers p-Pb 1-x Sn x Te (0.17 ≤x≤ 0.26) is investigated. Saturation of radiation flux dependences of hole density due to occurrence of a resonance level under irradiation, which is near the ceiling of the valence band of alloys, and due to stabilization of the Fermi level with the resonance level is detected. Possibility of coordination of novadays data on the position of the levels of radiation defects in alloys Pb 1-x Sn x Te is discussed

  11. Crystal growth and characterization of Ce:Gd.sub.3./sub.(Ga,Al).sub.5./sub.O.sub.12./sub. single crystal using floating zone method in different O.sub.2./sub. partial pressure

    Czech Academy of Sciences Publication Activity Database

    Yoshikawa, A.; Fujimoto, Y.; Yamaji, A.; Kurosawa, S.; Pejchal, Jan; Sugiyama, M.; Wakahara, S.; Futami, Y.; Yokota, Y.; Kamada, K.; Yubuta, K.; Shishido, T.; Nikl, Martin

    2013-01-01

    Roč. 35, č. 11 (2013), s. 1882-1886 ISSN 0925-3467 R&D Projects: GA MŠk LH12150 Institutional support: RVO:68378271 Keywords : Ce:GAGG * scintillator * single crystal * floating zone method * growth atmosphere * combinatorial Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.075, year: 2013 http://www.sciencedirect.com/science/article/pii/S0925346713001523

  12. Proton minibeam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Girst, Stefanie

    2016-03-08

    The risk of developing adverse side effects in the normal tissue after radiotherapy is often limiting for the dose that can be applied to the tumor. Proton minibeam radiotherapy, a spatially fractionated radiotherapy method using sub-millimeter proton beams, similar to grid therapy or microbeam radiation radiotherapy (MRT) using X-rays, has recently been invented at the ion microprobe SNAKE in Munich. The aim of this new concept is to minimize normal tissue injuries in the entrance channel and especially in the skin by irradiating only a small percentage of the cells in the total irradiation field, while maintaining tumor control via a homogeneous dose in the tumor, just like in conventional broad beam radiotherapy. This can be achieved by optimizing minibeam sizes and distances according to the prevailing tumor size and depth such that after widening of the minibeams due to proton interactions in the tissue, the overlapping minibeams produce a homogeneous dose distribution throughout the tumor. The aim of this work was to elucidate the prospects of minibeam radiation therapy compared to conventional homogeneous broad beam radiotherapy in theory and in experimental studies at the ion microprobe SNAKE. Treatment plans for model tumors of different sizes and depths were created using the planning software LAPCERR, to elaborate suitable minibeam sizes and distances for the individual tumors. Radiotherapy-relevant inter-beam distances required to obtain a homogeneous dose in the target volume were found to be in the millimeter range. First experiments using proton minibeams of only 10 μm and 50 μm size (termed microchannels in the corresponding publication Zlobinskaya et al. 2013) and therapy-conform larger dimensions of 100 μm and 180 μm were performed in the artificial human in-vitro skin model EpiDermFT trademark (MatTek). The corresponding inter-beam distances were 500 μm, 1mm and 1.8 mm, respectively, leading to irradiation of only a few percent of the cells

  13. 40 CFR 65.45 - External floating roof converted into an internal floating roof.

    Science.gov (United States)

    2010-07-01

    ... External floating roof converted into an internal floating roof. The owner or operator who elects to... 40 Protection of Environment 15 2010-07-01 2010-07-01 false External floating roof converted into an internal floating roof. 65.45 Section 65.45 Protection of Environment ENVIRONMENTAL PROTECTION...

  14. Doping of semiconductors using radiation defects produced by irradiation with protons and alpha particles

    International Nuclear Information System (INIS)

    Kozlov, V.A.; Kozlovski, V.V.

    2001-01-01

    One of the modern methods for modifying semiconductors using beams of protons and alpha particles is analyzed; this modification is accomplished by the controlled introduction of radiation defects into the semiconductor. It is shown that doping semiconductors with radiation defects produced by irradiation with light ions opens up fresh opportunities for controlling the properties of semiconducting materials and for the development of new devices designed for optoelectronics, microelectronics, and nanoelectronics based on these materials; these devices differ favorably from those obtained by conventional doping methods, i.e., by diffusion, epitaxy, and ion implantation

  15. Seven centuries of atmospheric Pb deposition recorded in a floating mire from Central Italy

    Science.gov (United States)

    Zaccone, Claudio; Lobianco, Daniela; D'Orazio, Valeria; Miano, Teodoro M.; Shotyk, William

    2016-04-01

    Floating mires generally consist of emergent vegetation rooted in highly organic buoyant mats that rise and fall with changes in water level. Generally speaking, the entire floating mass (mat) is divided into a mat root zone and an underlying mat peat zone. Floating mires are distributed world-wide; large areas of floating marsh occur along rivers and lakes in Africa, the Danube Delta in Romania, the Amazon River in South America, and in the Mississippi River delta in USA, whereas smaller areas occur also in The Netherlands, Australia and Canada. While peat cores from ombrotrophic bogs have been often (and successfully) used to reconstruct changes in the atmospheric deposition of several metals (including Pb), no studies are present in literature about the possibility to use peat profiles from floating mires. To test the hypothesis that peat-forming floating mires could provide an exceptional tool for environmental studies, a complete, 4-m deep peat profile was collected in July 2012 from the floating island of Posta Fibreno, a relic mire in the Central Italy. This floating island has a diameter of ca. 30 m, a submerged thickness of about 3 m, and the vegetation is organized in concentric belts, from the Carex paniculata palisade to the Sphagnum palustre centre. The whole core was frozen cut each 1-to-2 cm (n =231), and Pb determined by quadrupole ICP-MS (at the ultraclean SWAMP lab, University of Alberta, Canada) in each sample throughout the first 100 cm, and in each odd-numbered slice for the remaining 300 cm. The 14C age dating of organic sediments (silty peat) isolated from the sample at 385 cm of depth revealed that the island probably formed ca. 700 yrs ago. Lead concentration trend shows at least two main zones of interest, i.e., a clear peak (ranging from 200 to 1600 ppm) between 110-115 cm of depth, probably corresponding to early 1960's - late 1970's, and a broad band (80-160 ppm) between 295-320 cm of depth, corresponding to approximately AD 1480

  16. Characterization of proton and neutron irradiated low resistivity p-on-n magnetic Czochralski ministrip sensors and diodes

    Energy Technology Data Exchange (ETDEWEB)

    Pacifico, Nicola, E-mail: nicola.pacifico@cern.ch [CERN, Geneva (Switzerland); Dolenc Kittelmann, Irena; Fahrer, Manuel; Moll, Michael [CERN, Geneva (Switzerland); Militaru, Otilia [UCL, Louvain (Belgium)

    2011-12-01

    Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements were performed on low resistivity (280{Omega}cm) n-bulk, p-readout magnetic Czochralski ministrip sensors and diodes. The detectors were irradiated with neutrons and 24 GeV/c protons up to a total NIEL equivalent fluence of 8 Multiplication-Sign 10{sup 15}/cm{sup 2}. The study was addressed to assess the radiation tolerance of the detectors up to fluences expected in the next generations of High Energy Physics experiments. The charge collection efficiency after irradiation was found to be much higher than for standard FZ silicon p-in-n sensors. The underlying physics of this remarkable result was investigated by performing Edge-TCT measurements on one of the neutron irradiated ministrip sensors to extract detailed informations about the field and efficiency profiles of the detector.

  17. Dynamics and adsorption of gas molecules using proton beams

    International Nuclear Information System (INIS)

    Kim, J. Y.; Kim, E. K.; Lee, J. K.

    2008-04-01

    We irradiated nano sized MgO powders and carbon nanotubes by proton beams with energy of 35 MeV for different dosing time and the difference before and after the irradiation was investigated by using NO and Ar gas adsorptions studies. Particular interest was given to the irradiation of proton beams on quasicrystals made with Ti-Zr-Ni to remove the oxygen layer on the surface of the sample. Quasicrystals are known to exhibit a 5-fold rotational symmetry which is theoretically forbidden in a concept of solid state physics, and have a potential applications on large amount of hydrogen loading due to their structural complexity and chemical affinity with hydrogen. The results are summarized as four major accomplishments. 1) Proton irradiated MgO powders demonstrated the increased number of NO atomic layers in a layer-by-layer fashion suggesting that the surface of the sample became homogeneous compare to the pure samples. 2) the synchrotron based X-ray diffraction data suggests that NO molecules form an 1x1 commensurate structure on MgO (100) surface evidenced by the NO peak location at the Q values of 2.12 A -1 . 3) Proton irradiated SWCNTs exhibit the uniform Ar atomic layer formation suggesting that the surface of the CNTs can be homonized by the proton beam irradiation, and 4) 20 MeV of proton beam can effectively remove the oxygen layer on metal oxides so that Ti-Zr-Ni quasicrystals can load a large amount of hydrogen (exceeding to the density of liquid hydrogen) at room temperature.

  18. Conceptual design for irradiation device used to irradiate experimental LFR fuel element in TRIGA reactor, ACPR zone

    International Nuclear Information System (INIS)

    Ioan, M.

    2013-01-01

    The paper presents the main steps followed to conceive a small, versatile and rather cheep irradiation device used for irradiation of an experimental fuel element, specific for Lead cooled Fast Reactor (LFR), adapted to TRIGA reactor, ACPR zone. This device must be instrumented with at least 4 thermocouples and a pressure transducer. The fuel element (150 mm fuel pellets column) will be immersed in maximum 0.350 kg pure hot lead (400 deg C). The system has three protection barriers, as follows: first is the fuel tube, second is the lead container (maximum 20 mm inner diameter) and third is the external container (maximum 180 mm outside diameter). Before the reactor pulse, the temperature of the lead is set at the prescribed value using an electrical heater (300 W), coil on the second barrier. Outside the second barrier a very good thermal insulation is provided. (authors)

  19. Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness

    CERN Document Server

    Maiti, Moumita; Mendonça, Tania M; Stora, Thierry; Lahiri, Susanta

    2014-01-01

    This is the first report on the inventory of radionuclides produced in 1.4 GeV proton induced reaction on Lead-Bismuth Eutectic (LBE) targets. LBE targets of 6 mm diameter and 1 to 8 mm lengths were irradiated with 1.4 GeV protons. The radionuclides ranging from Be-7 (53.12 days) to Po-207 (5.8 h) were identified in the samples with the help of time resolved gamma-ray spectroscopy. However, there is no signature of formation of At radioisotopes, which can be produced by the interaction of secondary particles, typical for thick targets.

  20. Cross sections for the production of Li and Be isotopes in carbon targets irradiated by 300 GeV protons

    International Nuclear Information System (INIS)

    Raisbeck, G.M.; Lestringuez, J.; Yiou, F.

    1975-01-01

    Cross sections for the production of Li and Be isotopes in carbon targets irradiated by 300 GeV protons were measured by mass spectrometry. The results are compared with lower energy measurements and discussed in terms of the variation of the cosmic ray L/M ratio in this energy region [fr

  1. Overflow Water Pathways in the Subpolar North Atlantic Observed with Deep Floats

    Science.gov (United States)

    Bower, Amy; Furey, Heather; Lozier, Susan

    2017-04-01

    As part of the Overturning in the Subpolar North Atlantic Program (OSNAP), a total of 135 acoustically tracked RAFOS floats have been deployed in the deep boundary currents of the Iceland, Irminger and Labrador Basins, and in the Charlie-Gibbs Fracture Zone, to investigate the pathways of Iceland-Scotland Overflow Water (ISOW) and Denmark Strait Overflow Water (DSOW). Floats were released annually in 2014, 2015 and 2016 at depths between 1800 and 2800 m for two-year missions. The array of sound sources used for tracking was expanded from 10 to 13 moorings in 2016 when it was discovered that wintertime surface roughness was negatively impacting acoustic ranges. The floats from the first setting reveal several examples of persistent , deep coherent eddy motion, including a cyclonic eddy spinning off the tip of Eirik Ridge (southwest of Cape Farewell), a cyclonic eddy in the northeastern Labrador Basin near where anticyclonic Irminger Rings are formed, and an anticyclonic eddy under the North Atlantic Current (NAC) in the central Iceland Basin. A consistent region of boundary-interior exchange was observed near Hamilton Bank on the western boundary of the Labrador Sea. Deep cyclonic recirculation gyres are revealed in all three basins. Floats released in the southward-flowing deep boundary current over the eastern flank of the Reykjanes Ridge show that shallower layers of ISOW peel off to the west and cross the Ridge into the Irminger Basin through various gaps south of 60°N, including the Bight Fracture Zone. These floats tend to turn northward and continue along the slope in the Irminger Basin. Interestingly, floats released at the ISOW level in the CGFZ did not turn into the Irminger Basin as often depicted in deep circulation schematics, but rather drifted west-northwestward toward the Labrador Sea, or eddied around west of the CGFZ and (in some cases) turned southward. This result is consistent with some previous hydrographic and high-resolution model results

  2. WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

    Energy Technology Data Exchange (ETDEWEB)

    McAuley, G; Slater, J [Loma Linda University, Loma Linda, CA (United States); Wroe, A [Loma Linda University Medical Center, Loma Linda, CA (United States)

    2014-06-15

    Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment

  3. Monte Carlo modelling and comparison with experiment of the nuclide production in thick stony targets isotropically irradiated with 600 MeV protons

    International Nuclear Information System (INIS)

    Aylmer, D.; Herzog, G.F.; Kruse, T.H.; Cloth, P.; Filges, D.; Moniot, R.K.; Signer, P.; Wieler, R.; Tuniz, C.

    1987-05-01

    Depth profiles for the production of stable and radioactive nuclides have been measured for a large variety of target elements in three thick spherical stony targets with radii of 5, 15 and 26 cm isotropically irradiated with 600 MeV protons at the CERN synchrocyclotron. These irradiation experiments (CERN SC96) were intended to simulate the irradiation of meteoroids by galactic cosmic ray protons. In order to combine this experimental approach with a theoretical one the intra- and internuclear cascades were calculated using Monte Carlo techniques via the high energy transport code HET/KFA 1. Together with transport calculations for low energy neutrons by the MORSE-CG code the depth dependent spectra of primary and secondary protons and of secondary neutrons were derived. On the basis of these spectra and a set of evaluated experimental excitation functions for p-induced reactions and of theoretical ones for n-induced reactions, calculated by the code ALICE LIVERMORE 82, theoretical depth profiles for the production of stable and radioactive nuclides in the three thick targets were calculated. This report is a comprehensive survey on all those target/product combination for which both experimental and theoretical data are available. It provides the basis for a detailed discussion of the various production modes of residual nuclides and on the depth and size dependence of their production rates in thick stony targets, serving as a simulation of the galactic cosmic ray irradiation of meteoroids in space. On the other hand the comparison of the experimental and theoretical depth profiles validates the high energy transport calculations, making them a promissing tool for further model calculations of the interactions of cosmic rays with matter. (orig.)

  4. Quantification of rat retinal growth and vascular population changes after single and split doses of proton irradiation: translational study using stereology methods

    Science.gov (United States)

    Mao, Xiao W.; Archambeau, John O.; Kubinova, Lucie; Boyle, Soames; Petersen, Georgia; Grove, Roger; Nelson, G. A. (Principal Investigator)

    2003-01-01

    This study quantified architectural and population changes in the rat retinal vasculature after proton irradiation using stereology. A 100 MeV conformal proton beam delivered 8, 14, 20 and 28 Gy as single and split doses to the whole eye. The vascular networks were prepared from retinal digests. Stereological methods were used to obtain the area of the retina and unbiased estimates of microvessel/artery/vein endothelial, pericyte and smooth muscle population, and vessel length. The retinal area increased progressively in the unirradiated, age-matched controls and in the retinas irradiated with 8 and 14 Gy, indicating uniform progressive retinal growth. No growth occurred after 20 and 28 Gy. Regression analysis of total endothelial cell number in all vessels (arteries, veins and capillaries) after irradiation documented a progressive time- and dose-dependent cell loss occurring over 15 to 24 months. The difference from controls was significant (Ppopulations after split doses. At 10 Gy, the rate of endothelial cell loss, a dose parameter used to characterize the time- and dose-dependent loss of the endothelial population, was doubled.

  5. Decursin was Accelerated Human Lung Cancer Cell Death Caused by Proton Beam Irradiation via Blocking the p42/44 MAPK pathway

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Myung Hwan; Ra, Se Jin; Kim, Kye Ryung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Decursin, which is one of the extract of Angelica gigas Nakai root, has been traditionally used in Korean folk medicine as a tonic and for treatment of anemia and other common diseases. There are some reports about the pharmacological properties of decursin showing anti-bacterial and anti-amnestic effect, depression of cardiac contraction, antitumor and anti-angiogenic activity. Cell death induced by proton beam is identified as apoptosis. The study investigated that genes involved in apoptosis are checked by RT-PCR and used LET instead of SPBP of proton beam. Apoptosis is the tight regulated by multi-protein action in physiological cell death program. Proton therapy is an attractive approach for the treatment of deep-seated tumor. Recently, many researchers tried to new therapeutic strategy, combination of proton therapy and chemotherapy, in order to increase therapeutic effect. In this study, we investigate whether decursin can accelerate effect of human lung cell apoptosis in proton irradiated cancer cells

  6. Cross sections for the production of Li and Be isotopes in carbon targets irradiated by 300 GeV protons

    International Nuclear Information System (INIS)

    Raisbeck, G.M.; Lestringuez, J.; Yiou, F.

    1975-01-01

    Cross sections for the production of Li and Be isotopes in carbon targets irradiated by 300 GeV protons have been measured by mass spectrometry. The results are compared with lower energy measurements and discussed in terms of the variation of the cosmic ray L/M ratio in the energy region [fr

  7. Geant4 Monte Carlo simulation of absorbed dose and radiolysis yields enhancement from a gold nanoparticle under MeV proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, H.N., E-mail: tranngochoang@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Karamitros, M. [Notre Dame Radiation Laboratory, University of Notre-Dame, IN 46556 (United States); Ivanchenko, V.N. [Geant4 Associates International Ltd, Hebden Bridge (United Kingdom); Guatelli, S.; McKinnon, S. [Centre For Medical Radiation Physics, University of Wollongong (Australia); Illawarra Health and Medical Research, University of Wollongong, NSW (Australia); Murakami, K.; Sasaki, T.; Okada, S. [Computing Research Center, High Energy Accelerator Organization, KEK, Tsukuba City (Japan); Bordage, M.C. [INSERM, UMR 1037, CRCT, F-31000 Toulouse (France); Univ. Toulouse III-Paul Sabatier, UMR 1037, CRCT, F-31000 Toulouse (France); Francis, Z. [Saint Joseph University, Faculty of Sciences, Department of Physics, Beirut (Lebanon); El Bitar, Z. [Institut Pluridisciplinaire Hubert Curien/IN2P3/CNRS, Strasbourg (France); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Shin, J.I. [Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, 75, Nowon-ro, Nowon-gu, Seoul (Korea, Republic of); Lee, S.B. [Proton Therapy Center, National Cancer Center, 323, Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do (Korea, Republic of); Barberet, Ph. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Tran, T.T. [VNUHCM-University of Science (Viet Nam); Brown, J.M.C. [School of Mathematics and Physics, Queen’s University Belfast, Belfast, Northern Ireland (United Kingdom); and others

    2016-04-15

    Gold nanoparticles have been reported as a possible radio-sensitizer agent in radiation therapy due to their ability to increase energy deposition and subsequent direct damage to cells and DNA within their local vicinity. Moreover, this increase in energy deposition also results in an increase of the radiochemical yields. In this work we present, for the first time, an in silico investigation, based on the general purpose Monte Carlo simulation toolkit Geant4, into energy deposition and radical species production around a spherical gold nanoparticle 50 nm in diameter via proton irradiation. Simulations were preformed for incident proton energies ranging from 2 to 170 MeV, which are of interest for clinical proton therapy.

  8. Assessing biological and chemical signatures related to nutrient removal by floating islands in stormwater mesocosms.

    Science.gov (United States)

    Chang, Ni-Bin; Islam, Kamrul; Marimon, Zachary; Wanielista, Martin P

    2012-07-01

    Aquatic floating plants on BioHaven mats were tested for their potential use as a Best Management Practice to be incorporated within existing stormwater detention ponds. Plants were analyzed for their capability to remove nutrient-pollution in parallel with the study of ecological dynamics. Experiments were carried out in cylindrical mesocosms of 5 m diameter and 1.2 m height, above-ground pools with a water volume of 14 m(3). The design parameters tested were for 5% and 10% vegetated floating island coverage of the mesocosm, both with and without shoreline plants called littoral zone. This littoral shelf was 0.5 m thick, graded at a downward slope of 1:5 toward the center using loamy soil with low organic matter content, excavated from below turf grass. Endemic plant species were chosen for the experimental location in central Florida based on a wetland identification manual by the Florida Department of Environmental Protection to ensure the study was not compromised by unique climate requirements of the plants. Nutrient and aquatic chemical conditions such as pH, dissolved oxygen, temperature, turbidity, and chlorophyll a were monitored to understand their relationships to the general wetland ecosystem. Real-time polymerase chain reaction analysis identified the microbial activity near the rhizospheric zone. Logistical placement considerations were made using spatial sampling across the horizontal plane of the mesocosms, beneath and around the root zone, to determine if nutrients tend to aggregate around the floating island. This study concluded that the application of floating islands as a stormwater technology can remove nutrients through plant uptake and biological activity. The most cost-effective size in the outdoor mesocosms was 5% surface area coverage of the mat. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Induction of cancer cell death by proton beam in tumor hypoxic region

    International Nuclear Information System (INIS)

    Lee, Y. M.; Hur, T. R.; Lee, K. B.; Jeong, M. H.; Park, J. W.

    2007-04-01

    Proton beam induced apoptosis significantly in Lewis lung carcinoma cells and hepatoma HepG2 cells in a dose- and time-dependent manner, but slightly in leukemia Molt-4 cells. Relative biological effectiveness (RBE) values for death rate relative to gamma ray were ranged from 1.3 to 2.1 in LLC or HepG2 but 0.7 in Molt-4 cells at 72h after irradiation. The typical apoptosis was observed by nuclear DNA staining with DAPI. By FACS analysis after stained with PI, sub-G1 cell fraction was significantly increased but G2/M phase was not altered by proton beam irradiation measured at 24 h after irradiation. Proton beam-irradiated tumor cells induced cleavage of PARP-1 and procaspases (-3 and -9) and increased the level of p53 and p21. decreased pro-lamin B. Acitivity of caspases was significantly increased after proton beam irradiation. Furthermore, ROS were significantly increased and N-acetyl cystein (NAC) pretreatment restored the apoptotic cell death induced in proton beam-irradiated cells. In conclusion, single treatment of low energy proton beam with SOBP induced apoptosis of solid tumor cells via increased ROS, active caspase -3,-9 and p53, p2

  10. Induction of cancer cell death by proton beam in tumor hypoxic region

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. M.; Hur, T. R.; Lee, K. B.; Jeong, M. H.; Park, J. W. [Kyungbook National Univ., Daegu (Korea, Republic of)

    2007-04-15

    Proton beam induced apoptosis significantly in Lewis lung carcinoma cells and hepatoma HepG2 cells in a dose- and time-dependent manner, but slightly in leukemia Molt-4 cells. Relative biological effectiveness (RBE) values for death rate relative to gamma ray were ranged from 1.3 to 2.1 in LLC or HepG2 but 0.7 in Molt-4 cells at 72h after irradiation. The typical apoptosis was observed by nuclear DNA staining with DAPI. By FACS analysis after stained with PI, sub-G1 cell fraction was significantly increased but G2/M phase was not altered by proton beam irradiation measured at 24 h after irradiation. Proton beam-irradiated tumor cells induced cleavage of PARP-1 and procaspases (-3 and -9) and increased the level of p53 and p21. decreased pro-lamin B. Acitivity of caspases was significantly increased after proton beam irradiation. Furthermore, ROS were significantly increased and N-acetyl cystein (NAC) pretreatment restored the apoptotic cell death induced in proton beam-irradiated cells. In conclusion, single treatment of low energy proton beam with SOBP induced apoptosis of solid tumor cells via increased ROS, active caspase -3,-9 and p53, p2.

  11. High intensity proton accelerator and its application (Proton Engineering Center)

    International Nuclear Information System (INIS)

    Tanaka, Shun-ichi

    1995-01-01

    A plan called PROTON ENGINEERING CENTER has been proposed in JAERI. The center is a complex composed of research facilities and a beam shape and storage ring based on a proton linac with an energy of 1.5 GeV and an average current of 10 mA. The research facilities planned are OMEGA·Nuclear Energy Development Facility, Neutron Facility for Material Irradiation, Nuclear Data Experiment Facility, Neutron Factory, Meson Factory, Spallation Radioisotope Beam Facility, and Medium Energy Experiment Facility, where high intensity proton beam and secondary particle beams such as neutrons, π-mesons, muons, and unstable isotopes originated from the protons are available for promoting the innovative research of nuclear energy and basic science and technology. (author)

  12. Formation of Nanodroplets in N2/H2O/SO2 under Irradiation of Fast Proton Beams

    DEFF Research Database (Denmark)

    Nakai, Youchi; Shigeoka, Tomita; Funada, Shuhei

    of the droplet growth in thebinary nucleation process of water and H2SO4.We have performed irradiation of proton beam on the gas mixture of N2/H2O/SO2 andAir/H2O/SO2. The reduction of SO2 concentration by beam irradiation was monitored usingan SO2 meter and the size distributions of generated droplets were...

  13. Proton solar flares

    International Nuclear Information System (INIS)

    Shaposhnikova, E.F.

    1979-01-01

    The observations of proton solar flares have been carried out in 1950-1958 using the extrablackout coronograph of the Crimea astrophysical observatory. The experiments permit to determine two characteristic features of flares: the directed motion of plasma injection flux from the solar depths and the appearance of a shock wave moving from the place of the injection along the solar surface. The appearance of the shock wave is accompanied by some phenomena occuring both in the sunspot zone and out of it. The consistent flash of proton flares in the other groups of spots, the disappearance of fibres and the appearance of eruptive prominences is accomplished in the sunspot zone. Beyond the sunspot zone the flares occur above spots, the fibres disintegrate partially or completely and the eruptive prominences appear in the regions close to the pole

  14. Energy related germination and survival rates of water-imbibed Arabidopsis seeds irradiated with protons

    International Nuclear Information System (INIS)

    Qin, H.L.; Xue, J.M.; Lai, J.N.; Wang, J.Y.; Zhang, W.M.; Miao, Q.; Yan, S.; Zhao, W.J.; He, F.; Gu, H.Y.; Wang, Y.G.

    2006-01-01

    In order to investigate the influence of ion energy on the germination and survival rates, water-imbibed Arabidopsis seeds were irradiated with protons in atmosphere. The ion fluence used in this experiment was in the range of 4 x 10 9 -1 x 10 14 ions/cm 2 . The ion energy is from 1.1 MeV to 6.5 MeV. According to the structure of the seed and TRIM simulation, the ions with the energy of 6.5 MeV can irradiate the shoot apical meristem directly whereas the ions with the energy of 1.1 MeV cannot. The results showed that both the germination and survival rates decrease while increasing the ion fluence, and the fluence-respond curve for each energy has different character. Besides the shoot apical meristem (SAM), which is generally considered as the main radiobiological target, the existence of a secondary target around SAM is proposed in this paper

  15. Seminar | Development of a PET Cyclotron Based Irradiation Setup for Proton Radiobiology | 25 June

    CERN Multimedia

    2015-01-01

    Sharif Hasan Mahmoud Ghithan, a Palestinian postdoctoral researcher at the Laboratory of Instrumentation and Experimental Particle Physics (Portugal), will discuss the development of an out-of-yoke irradiation setup using the proton beam from a cyclotron that ordinarily produces radioisotopes for Positron Emission Tomography (PET). The speaker will also discuss possible future use of the results of this research for CERN’s new LEIR biomedical facility. The seminar will be proposed in the framework of a meeting of the CERN Medical Applications Study Group.   25 June, 2 p.m. to 3 p.m. Room 13-2-005 ABSTRACT: In this new irradiation setup, the current from a 20 mm thick aluminum transmission foil is read out by homemade transimpedance electronics, providing online dose information. The main monitoring variables, delivered in real-time, include beam current, integrated charge and dose rate. Hence the dose and integrated current delivered at a given instant to an experimental setu...

  16. Energy related germination and survival rates of water-imbibed Arabidopsis seeds irradiated with protons

    Energy Technology Data Exchange (ETDEWEB)

    Qin, H.L. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Xue, J.M. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Lai, J.N. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Wang, J.Y. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Zhang, W.M. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Miao, Q. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Yan, S. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); Zhao, W.J. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China); He, F. [School of Life Science, Peking University, Beijing 100871 (China); Gu, H.Y. [School of Life Science, Peking University, Beijing 100871 (China); Wang, Y.G. [Key Laboratory of Heavy Ion Physics, MOE, Peking University, Beijing 100871 (China)]. E-mail: ygwang@pku.edu.cn

    2006-04-15

    In order to investigate the influence of ion energy on the germination and survival rates, water-imbibed Arabidopsis seeds were irradiated with protons in atmosphere. The ion fluence used in this experiment was in the range of 4 x 10{sup 9}-1 x 10{sup 14} ions/cm{sup 2}. The ion energy is from 1.1 MeV to 6.5 MeV. According to the structure of the seed and TRIM simulation, the ions with the energy of 6.5 MeV can irradiate the shoot apical meristem directly whereas the ions with the energy of 1.1 MeV cannot. The results showed that both the germination and survival rates decrease while increasing the ion fluence, and the fluence-respond curve for each energy has different character. Besides the shoot apical meristem (SAM), which is generally considered as the main radiobiological target, the existence of a secondary target around SAM is proposed in this paper.

  17. Investigation of the double exponential in the current-voltage characteristics of silicon solar cells. [proton irradiation effects on ATS 1 cells

    Science.gov (United States)

    Wolf, M.; Noel, G. T.; Stirn, R. J.

    1977-01-01

    Difficulties in relating observed current-voltage characteristics of individual silicon solar cells to their physical and material parameters were underscored by the unexpected large changes in the current-voltage characteristics telemetered back from solar cells on the ATS-1 spacecraft during their first year in synchronous orbit. Depletion region recombination was studied in cells exhibiting a clear double-exponential dark characteristic by subjecting the cells to proton irradiation. A significant change in the saturation current, an effect included in the Sah, Noyce, Shockley formulation of diode current resulting from recombination in the depletion region, was caused by the introduction of shallow levels in the depletion region by the proton irradiation. This saturation current is not attributable only to diffusion current from outside the depletion region and only its temperature dependence can clarify its origin. The current associated with the introduction of deep-lying levels did not change significantly in these experiments.

  18. Comparison of therapeutic dosimetric data from passively scattered proton and photon craniospinal irradiations for medulloblastoma

    Directory of Open Access Journals (Sweden)

    Howell Rebecca M

    2012-07-01

    Full Text Available Abstract Background For many decades, the standard of care radiotherapy regimen for medulloblastoma has been photon (megavoltage x-rays craniospinal irradiation (CSI. The late effects associated with CSI are well-documented in the literature and are in-part attributed to unwanted dose to healthy tissue. Recently, there is growing interest in using proton therapy for CSI in pediatric and adolescent patients to reduce this undesirable dose. Previous comparisons of dose to target and non-target organs from conventional photon CSI and passively scattered proton CSI have been limited to small populations (n ≤ 3 and have not considered the use of age-dependent target volumes in proton CSI. Methods Standard of care treatment plans were developed for both photon and proton CSI for 18 patients. This cohort included both male and female medulloblastoma patients whose ages, heights, and weights spanned a clinically relevant and representative spectrum (age 2–16, BMI 16.4–37.9 kg/m2. Differences in plans were evaluated using Wilcoxon signed rank tests for various dosimetric parameters for the target volumes and normal tissue. Results Proton CSI improved normal tissue sparing while also providing more homogeneous target coverage than photon CSI for patients across a wide age and BMI spectrum. Of the 24 parameters (V5, V10, V15, and V20 in the esophagus, heart, liver, thyroid, kidneys, and lungs Wilcoxon signed rank test results indicated 20 were significantly higher for photon CSI compared to proton CSI (p ≤ 0.05 . Specifically, V15 and V20 in all six organs and V5, V10 in the esophagus, heart, liver, and thyroid were significantly higher with photon CSI. Conclusions Our patient cohort is the largest, to date, in which CSI with proton and photon therapies have been compared. This work adds to the body of literature that proton CSI reduces dose to normal tissue compared to photon CSI for pediatric patients who are at substantial risk for

  19. Comparison of therapeutic dosimetric data from passively scattered proton and photon craniospinal irradiations for medulloblastoma

    International Nuclear Information System (INIS)

    Howell, Rebecca M; Giebeler, Annelise; Koontz-Raisig, Wendi; Mahajan, Anita; Etzel, Carol J; D’Amelio, Anthony M Jr; Homann, Kenneth L

    2012-01-01

    For many decades, the standard of care radiotherapy regimen for medulloblastoma has been photon (megavoltage x-rays) craniospinal irradiation (CSI). The late effects associated with CSI are well-documented in the literature and are in-part attributed to unwanted dose to healthy tissue. Recently, there is growing interest in using proton therapy for CSI in pediatric and adolescent patients to reduce this undesirable dose. Previous comparisons of dose to target and non-target organs from conventional photon CSI and passively scattered proton CSI have been limited to small populations (n ≤ 3) and have not considered the use of age-dependent target volumes in proton CSI. Standard of care treatment plans were developed for both photon and proton CSI for 18 patients. This cohort included both male and female medulloblastoma patients whose ages, heights, and weights spanned a clinically relevant and representative spectrum (age 2–16, BMI 16.4–37.9 kg/m2). Differences in plans were evaluated using Wilcoxon signed rank tests for various dosimetric parameters for the target volumes and normal tissue. Proton CSI improved normal tissue sparing while also providing more homogeneous target coverage than photon CSI for patients across a wide age and BMI spectrum. Of the 24 parameters (V 5 , V 10 , V 15 , and V 20 in the esophagus, heart, liver, thyroid, kidneys, and lungs) Wilcoxon signed rank test results indicated 20 were significantly higher for photon CSI compared to proton CSI (p ≤ 0.05) . Specifically, V 15 and V 20 in all six organs and V 5 , V 10 in the esophagus, heart, liver, and thyroid were significantly higher with photon CSI. Our patient cohort is the largest, to date, in which CSI with proton and photon therapies have been compared. This work adds to the body of literature that proton CSI reduces dose to normal tissue compared to photon CSI for pediatric patients who are at substantial risk for developing radiogenic late effects. Although the present study

  20. Induction of cancer cell death by proton beam in tumor hypoxic region

    International Nuclear Information System (INIS)

    Lee, Y. M.; Heo, T. R.; Lee, K. B.; Jang, K. H.; Kim, H. N.; Lee, S. H.; Jeong, M. H.

    2008-04-01

    Proton beam has been applied to treat various tumor patients in clinical studies. However, it is still undefined whether proton radiation can inhibit the blood vessel formation and induce the cell death in vascular endothelial cells in growing organs. The aim of this study are first, to develop an optimal animal model for the observation of blood vessel development with low dose of proton beam and second, to investigate the effect of low dose proton beam on the inhibition of blood vessel formation induced by hypoxic conditions. In this study, flk1-GFP transgenic zebrafish embryos were used to directly visualize and determine the inhibition of blood vessels by low dose (1, 2, 5 Gy) of proton beam with spread out Bragg peak (SOBP). And we observed cell death by acridine orange staining at 96 hours post fertilization (hpf) stage of embryos after proton irradiation. We also compared the effects of proton beam with those of gamma-ray. An antioxidant, N-acetyl cystein (NAC) was used to investigate whether reactive oxygen species (ROS) were involved in the cell deaths induced by proton irradiation. Irradiated flk-1-GFP transgenic embryos with proton beam irradiation (35 MeV, spread out Bragg peak, SOBP) demonstrated a marked inhibition of embryonic growth and an altered fluorescent blood vessel development in the trunk region. When the cells with DNA damage in the irradiated zebrafish were stained with acridine orange, green fluorescent cell death spots were increased in trunk regions compared to non-irradiated control embryos. Proton beam also significantly increased the cell death rate in human umbilical vein endothelial cells (HUVEC), but pretreatment of N-acetyl cystein (NAC), an antioxidant, recovered the proton-induced cell death rate (p<0.01). Moreover, pretreatment of NAC abrogated the effect of proton beam on the inhibition of trunk vessel development and malformation of trunk truncation. From this study, we found that proton radiation therapy can inhibit the

  1. FLOAT Project

    DEFF Research Database (Denmark)

    Sørensen, Eigil V.; Aarup, Bendt

    The objective of the FLOAT project is to study the reliability of high-performance fibre-reinforced concrete, also known as Compact Reinforced Composite (CRC), for the floats of wave energy converters. In order to reach a commercial breakthrough, wave energy converters need to achieve a lower price...

  2. Cellular and Behavioral Effects of Cranial Irradiation of the Subventricular Zone in Adult Mice

    Science.gov (United States)

    Lazarini, Françoise; Mouthon, Marc-André; Gheusi, Gilles; de Chaumont, Fabrice; Olivo-Marin, Jean-Christophe; Lamarque, Stéphanie; Abrous, Djoher Nora; Boussin, François D.; Lledo, Pierre-Marie

    2009-01-01

    Background In mammals, new neurons are added to the olfactory bulb (OB) throughout life. Most of these new neurons, granule and periglomerular cells originate from the subventricular zone (SVZ) lining the lateral ventricles and migrate via the rostral migratory stream toward the OB. Thousands of new neurons appear each day, but the function of this ongoing neurogenesis remains unclear. Methodology/Principal Findings In this study, we irradiated adult mice to impair constitutive OB neurogenesis, and explored the functional impacts of this irradiation on the sense of smell. We found that focal irradiation of the SVZ greatly decreased the rate of production of new OB neurons, leaving other brain areas intact. This effect persisted for up to seven months after exposure to 15 Gray. Despite this robust impairment, the thresholds for detecting pure odorant molecules and short-term olfactory memory were not affected by irradiation. Similarly, the ability to distinguish between odorant molecules and the odorant-guided social behavior of irradiated mice were not affected by the decrease in the number of new neurons. Only long-term olfactory memory was found to be sensitive to SVZ irradiation. Conclusion/Significance These findings suggest that the continuous production of adult-generated neurons is involved in consolidating or restituting long-lasting olfactory traces. PMID:19753118

  3. Cellular and behavioral effects of cranial irradiation of the subventricular zone in adult mice.

    Directory of Open Access Journals (Sweden)

    Françoise Lazarini

    2009-09-01

    Full Text Available In mammals, new neurons are added to the olfactory bulb (OB throughout life. Most of these new neurons, granule and periglomerular cells originate from the subventricular zone (SVZ lining the lateral ventricles and migrate via the rostral migratory stream toward the OB. Thousands of new neurons appear each day, but the function of this ongoing neurogenesis remains unclear.In this study, we irradiated adult mice to impair constitutive OB neurogenesis, and explored the functional impacts of this irradiation on the sense of smell. We found that focal irradiation of the SVZ greatly decreased the rate of production of new OB neurons, leaving other brain areas intact. This effect persisted for up to seven months after exposure to 15 Gray. Despite this robust impairment, the thresholds for detecting pure odorant molecules and short-term olfactory memory were not affected by irradiation. Similarly, the ability to distinguish between odorant molecules and the odorant-guided social behavior of irradiated mice were not affected by the decrease in the number of new neurons. Only long-term olfactory memory was found to be sensitive to SVZ irradiation.These findings suggest that the continuous production of adult-generated neurons is involved in consolidating or restituting long-lasting olfactory traces.

  4. Irradiation with protons in order to obtain new rice varieties

    International Nuclear Information System (INIS)

    Gonzalez, Maria C.; Cristo, Elizabeth; Fuentes, Jorge L.

    2001-01-01

    In the Laboratory of Genetics and Improvement of the National Institute of Agricultural Sciences was developed a Program of Genetic Improvement using Biotechnical and Nuclear Techniques in order to obtain new rice varieties of high yield potential under drought stress condition. For them different explants types were used starting from seeds of the Cuban variety of rice Amistad 82 irradiated with protons in dose of 10, 20, 30, 40, 50, 60, 70, 80, 90 and 100 Gy. The explants were cultivated in vitro in order to obtaining callus and later plant regenerate. The plant selected in vitro was multiplied being carried out several selection cycles under field conditions. A remarkable stimulation was observed from the regeneration of plants when using dose of 20 Gy and it was possible to select 4 promising lines that differ of the donor as for cycle, architecture of the plant and tolerance to drought. Tjis result demonstrates the potentialities of this radiation source for obtaining of new rice varieties

  5. Process and apparatus for irradiating film, and irradiated film

    International Nuclear Information System (INIS)

    1981-01-01

    A process for irradiating film is described, which consists of passing the film through an electron irradiation zone having an electron reflection surface disposed behind and generally parallel to the film; and disposing within the irradiation zone adjacent the edges of the film a lateral reflection member for reflecting the electrons toward the reflection surface to further reflect the reflected electrons towards the adjacent edges of the film. (author)

  6. Radiation defect distribution in silicon irradiated with 600 keV electrons

    International Nuclear Information System (INIS)

    Hazdra, P.; Dorschner, H.

    2003-01-01

    Low-doped n-type float zone silicon was irradiated with 600 keV electrons to fluences from 2x10 13 to 1x10 15 cm -2 . Radiation defects, their introduction rates and full-depth profiles were measured by two complementary methods - the capacitance deep level spectroscopy and the high-voltage current transient spectroscopy. Results show that, in the vicinity of the anode junction, the profile of vacancy-related defect centers is strongly influenced by electric field and an excessive generation of vacancies. In the bulk, the slope of the profile can be derived from the distribution of absorbed dose taking into the account the threshold energy necessary for Frenkel pair formation and the dependency of the defect introduction rate on electron energy

  7. Degradation mechanisms of 2 MeV proton irradiated AlGaN/GaN HEMTs

    International Nuclear Information System (INIS)

    Greenlee, Jordan D.; Anderson, Travis J.; Koehler, Andrew D.; Weaver, Bradley D.; Kub, Francis J.; Hobart, Karl D.; Specht, Petra; Dubon, Oscar D.; Luysberg, Martina; Weatherford, Todd R.

    2015-01-01

    Proton-induced damage in AlGaN/GaN HEMTs was investigated using energy-dispersive X-ray spectroscopy (EDS) and transmission electron microscopy (TEM), and simulated using a Monte Carlo technique. The results were correlated to electrical degradation using Hall measurements. It was determined by EDS that the interface between GaN and AlGaN in the irradiated HEMT was broadened by 2.2 nm, as estimated by the width of the Al EDS signal compared to the as-grown interface. The simulation results show a similar Al broadening effect. The extent of interfacial roughening was examined using high resolution TEM. At a 2 MeV proton fluence of 6 × 10 14 H + /cm 2 , the electrical effects associated with the Al broadening and surface roughening include a degradation of the ON-resistance and a decrease in the electron mobility and 2DEG sheet carrier density by 28.9% and 12.1%, respectively

  8. Degradation mechanisms of 2 MeV proton irradiated AlGaN/GaN HEMTs

    Energy Technology Data Exchange (ETDEWEB)

    Greenlee, Jordan D., E-mail: jordan.greenlee.ctr@nrl.navy.mil; Anderson, Travis J.; Koehler, Andrew D.; Weaver, Bradley D.; Kub, Francis J.; Hobart, Karl D. [U.S. Naval Research Laboratory, 4555 Overlook Ave. SW, Washington, DC 20375 (United States); Specht, Petra; Dubon, Oscar D. [University of California at Berkeley, Berkeley, California 94720 (United States); Luysberg, Martina [ERC, Research Center Juelich GmbH, 52425 Juelich (Germany); Weatherford, Todd R. [Naval Postgraduate School, Monterey, California 93943 (United States)

    2015-08-24

    Proton-induced damage in AlGaN/GaN HEMTs was investigated using energy-dispersive X-ray spectroscopy (EDS) and transmission electron microscopy (TEM), and simulated using a Monte Carlo technique. The results were correlated to electrical degradation using Hall measurements. It was determined by EDS that the interface between GaN and AlGaN in the irradiated HEMT was broadened by 2.2 nm, as estimated by the width of the Al EDS signal compared to the as-grown interface. The simulation results show a similar Al broadening effect. The extent of interfacial roughening was examined using high resolution TEM. At a 2 MeV proton fluence of 6 × 10{sup 14} H{sup +}/cm{sup 2}, the electrical effects associated with the Al broadening and surface roughening include a degradation of the ON-resistance and a decrease in the electron mobility and 2DEG sheet carrier density by 28.9% and 12.1%, respectively.

  9. Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient

    Science.gov (United States)

    Zhang, Rui; Howell, Rebecca M.; Giebeler, Annelise; Taddei, Phillip J.; Mahajan, Anita; Newhauser, Wayne D.

    2013-02-01

    Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans with 23.4 Gy or Gy (RBE) prescribed dose were computed: a three-field 6 MV photon therapy plan and a four-field proton therapy plan. The primary doses for both plans were determined using a commercial treatment planning system. Stray radiation doses for proton therapy were determined from Monte Carlo simulations, and stray radiation doses for photon therapy were determined from measured data. Dose-risk models based on the Biological Effects of Ionization Radiation VII report were used to estimate the risk of second cancer in eight tissues/organs. Baseline predictions of the relative risk for each organ were always less for proton CSI than for photon CSI at all attained ages. The total lifetime attributable risk of the incidence of second cancer considered after proton CSI was much lower than that after photon CSI, and the ratio of lifetime risk was 0.18. Uncertainty analysis revealed that the qualitative findings of this study were insensitive to any plausible changes of dose-risk models and mean radiation weighting factor for neutrons. Proton therapy confers lower predicted risk of second cancer than photon therapy for the pediatric medulloblastoma patient.

  10. Behavior of Particle Depots in Molten Silicon During Float-Zone Growth in Strong Magnetic Fields

    Science.gov (United States)

    Jauss, T.; Croell, A.; SorgenFrei, T.; Azizi, M.; Reimann, C.; Friedrich, J.; Volz, M. P.

    2014-01-01

    Solar cells made from directionally solidified silicon cover 57% of the photovoltaic industry's market [1]. One major issue during directional solidification of silicon is the precipitation of foreign phase particles. These particles, mainly SiC and Si3N4, are precipitated from the dissolved crucible coating, which is made of silicon nitride, and the dissolution of carbon monoxide from the furnace atmosphere. Due to their hardness and size of several hundred micrometers, those particles can lead to severe problems during the wire sawing process for wafering the ingots. Additionally, SiC particles can act as a shunt, short circuiting the solar cell. Even if the particles are too small to disturb the wafering process, they can lead to a grit structure of silicon micro grains and serve as sources for dislocations. All of this lowers the yield of solar cells and reduces the performance of cells and modules. We studied the behaviour of SiC particle depots during float-zone growth under an oxide skin, and strong static magnetic fields. For high field strengths of 3T and above and an oxide layer on the sample surface, convection is sufficiently suppressed to create a diffusive like regime, with strongly dampened convection [2, 3]. To investigate the difference between atomically rough phase boundaries and facetted growth, samples with [100] and [111] orientation were processed.

  11. High temperature tensile testing of modified 9Cr-1Mo after irradiation with high energy protons

    International Nuclear Information System (INIS)

    Toloczko, M.B.; Hamilton, M.L.; Maloy, S.A.

    2003-01-01

    This study examines the effect of tensile test temperatures ranging from 50 to 600 deg. C on the tensile properties of a modified 9Cr-1Mo ferritic steel after high energy proton irradiation at about 35-67 deg. C to doses from 1 to 3 dpa and 9 dpa. For the specimens irradiated to doses between 1 and 3 dpa, it was observed that the yield strength and ultimate strength decreased monotonically as a function of tensile test temperature, whereas the uniform elongation (UE) remained at approximately 1% for tensile test temperatures up to 250 deg. C and then increased for tensile test temperatures up to and including 500 deg. C. At 600 deg. C, the UE was observed to be less than the values at 400 and 500 deg. C. UE of the irradiated material tensile tested at 400-600 deg. C was observed to be greater than the values for the unirradiated material at the same temperatures. Tensile tests on the 9 dpa specimens followed similar trends

  12. Maskless proton beam writing in gallium arsenide

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, P. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom) and Nano-Electronics Centre, Advanced Technology Institute, University of Surrey, Guildford GU2 7XH (United Kingdom)]. E-mail: p.mistry@surrey.ac.uk; Gomez-Morilla, I. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Smith, R.C. [Nano-Electronics Centre, Advanced Technology Institute, University of Surrey, Guildford GU2 7XH (United Kingdom); Thomson, D. [Advanced Technology Institute, University of Surrey, Guildford GU2 7XH (United Kingdom); Grime, G.W. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Webb, R.P. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Gwilliam, R. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Jeynes, C. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Cansell, A. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Merchant, M. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Kirkby, K.J. [Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2007-07-15

    Proton beam writing (PBW) is a direct write technique that employs a focused MeV proton beam which is scanned in a pre-determined pattern over a target material which is subsequently electrochemically etched or chemically developed. By changing the energy of the protons the range of the protons can be changed. The ultimate depth of the structure is determined by the range of the protons in the material and this allows structures to be formed to different depths. PBW has been successfully employed on etchable glasses, polymers and semiconductor materials such as silicon (Si) and gallium arsenide (GaAs). This study reports on PBW in p-type GaAs and compares experimental results with computer simulations using the Atlas (copy right) semiconductor device package from SILVACO. It has already been proven that hole transport is required for the electrochemical etching of GaAs using Tiron (4,5-dihydroxy-m-benzenedisulfonic acid, di-sodium salt). PBW in GaAs results in carrier removal in the irradiated regions and consequently minimal hole transport (in these regions) during electrochemical etching. As a result the irradiated regions are significantly more etch resistant than the non-irradiated regions. This allows high aspect ratio structures to be formed.

  13. Maskless proton beam writing in gallium arsenide

    International Nuclear Information System (INIS)

    Mistry, P.; Gomez-Morilla, I.; Smith, R.C.; Thomson, D.; Grime, G.W.; Webb, R.P.; Gwilliam, R.; Jeynes, C.; Cansell, A.; Merchant, M.; Kirkby, K.J.

    2007-01-01

    Proton beam writing (PBW) is a direct write technique that employs a focused MeV proton beam which is scanned in a pre-determined pattern over a target material which is subsequently electrochemically etched or chemically developed. By changing the energy of the protons the range of the protons can be changed. The ultimate depth of the structure is determined by the range of the protons in the material and this allows structures to be formed to different depths. PBW has been successfully employed on etchable glasses, polymers and semiconductor materials such as silicon (Si) and gallium arsenide (GaAs). This study reports on PBW in p-type GaAs and compares experimental results with computer simulations using the Atlas (copy right) semiconductor device package from SILVACO. It has already been proven that hole transport is required for the electrochemical etching of GaAs using Tiron (4,5-dihydroxy-m-benzenedisulfonic acid, di-sodium salt). PBW in GaAs results in carrier removal in the irradiated regions and consequently minimal hole transport (in these regions) during electrochemical etching. As a result the irradiated regions are significantly more etch resistant than the non-irradiated regions. This allows high aspect ratio structures to be formed

  14. Offshore floating windmills

    International Nuclear Information System (INIS)

    1993-10-01

    The aim was to produce a general survey of the profitability of establishing floating offshore wind turbine arrays and to compare this with the cost and profitability of constructing offshore arrays with fixed foundations and arrays located on land sites. Aspects of design in all cases are described, also into relation to the special demands placed on dimensioning in relation to the types of location and foundation. The costs of the offshore arrays are evaluated in relation to capacity under conditions in Danish waters. The advantage of floating arrays is that they can be placed far out to sea where they can not be seen from the coast and thus not be considered to spoil the marine view. But as the water gets deeper the cost of floating foundations rises. It was found that it would not be technologically profitable to establish floating arrays at a depth of less than 30 - 40 meters which means that only the outer Danish waters can be taken into consideration. For depths of up to 70 meters, individual floating bases are more expensive than fixed ones but would be cheaper if a number of windmills could share the same anchor. For depths of more than 70 meters floating foundations would be the cheapest. The cost is dependent on the depth and distance from the coast and also on wind conditions. The main conclusion is that currently the cost of establishing wind turbine arrays in deeper outer waters on floating foundations is comparable to that of arrays sited at inner waters on solid foundations placed on the sea bed. (AB) (20 refs.)

  15. Irradiation Facilities at CERN

    CERN Document Server

    Gkotse, Blerina; Carbonez, Pierre; Danzeca, Salvatore; Fabich, Adrian; Garcia, Alia, Ruben; Glaser, Maurice; Gorine, Georgi; Jaekel, Martin, Richard; Mateu,Suau, Isidre; Pezzullo, Giuseppe; Pozzi, Fabio; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-01-01

    CERN provides unique irradiation facilities for applications in many scientific fields. This paper summarizes the facilities currently operating for proton, gamma, mixed-field and electron irradiations, including their main usage, characteristics and information about their operation. The new CERN irradiation facilities database is also presented. This includes not only CERN facilities but also irradiation facilities available worldwide.

  16. Feasibility of proton-activated implantable markers for proton range verification using PET

    Science.gov (United States)

    Cho, Jongmin; Ibbott, Geoffrey; Gillin, Michael; Gonzalez-Lepera, Carlos; Titt, Uwe; Paganetti, Harald; Kerr, Matthew; Mawlawi, Osama

    2013-11-01

    Proton beam range verification using positron emission tomography (PET) currently relies on proton activation of tissue, the products of which decay with a short half-life and necessitate an on-site PET scanner. Tissue activation is, however, negligible near the distal dose fall-off region of the proton beam range due to their high interaction energy thresholds. Therefore Monte Carlo simulation is often supplemented for comparison with measurement; however, this also may be associated with systematic and statistical uncertainties. Therefore, we sought to test the feasibility of using long-lived proton-activated external materials that are inserted or infused into the target volume for more accurate proton beam range verification that could be performed at an off-site PET scanner. We irradiated samples of ≥98% 18O-enriched water, natural Cu foils, and >97% 68Zn-enriched foils as candidate materials, along with samples of tissue-equivalent materials including 16O water, heptane (C7H16), and polycarbonate (C16H14O3)n, at four depths (ranging from 100% to 3% of center of modulation (COM) dose) along the distal fall-off of a modulated 160 MeV proton beam. Samples were irradiated either directly or after being embedded in Plastic Water® or balsa wood. We then measured the activity of the samples using PET imaging for 20 or 30 min after various delay times. Measured activities of candidate materials were up to 100 times greater than those of the tissue-equivalent materials at the four distal dose fall-off depths. The differences between candidate materials and tissue-equivalent materials became more apparent after longer delays between irradiation and PET imaging, due to the longer half-lives of the candidate materials. Furthermore, the activation of the candidate materials closely mimicked the distal dose fall-off with offsets of 1 to 2 mm. Also, signals from the foils were clearly visible compared to the background from the activated Plastic Water® and balsa wood

  17. Vergleich relevanter Parameter von Multipixelsensoren für Spurdetektoren nach Bestrahlung mit hohen Proton- und Neutronflüssen

    CERN Document Server

    Bergholz, Matthias; Reif, Jürgen; Husemann, Ulrich

    2016-01-01

    The further increase of the luminosity of the Large Hadron Collider ( LHC ) at CERN requires new sensors for the tracking detector of the Compact Muon Soleniod ( CMS ) experiment. These sensors must be more radiation hard and of a finer granularity to lower the occupancy. In addition the new sensor modules must have a lower material budget and have to be self triggering. Sensor prototypes, the so called “ MPix ”-sensors, produced on different materials were investigated for their radiation hardness. These sensors were fully charac- terized before and after irradiation. Of particular interest was the comparison of different bias methods, different materials and the influence of various geometries. The degeneration rate differs for the different sensor materials. The increase of the dark current of Float-Zone-Silicon is stronger for thicker sensors and less than for Magnetic-Czochralski-Silicon sensors. Both tested bias structures are damaged by the irradiation. The poly silicon resis- tance increases after...

  18. Handbook of floating-point arithmetic

    CERN Document Server

    Muller, Jean-Michel; de Dinechin, Florent; Jeannerod, Claude-Pierre; Joldes, Mioara; Lefèvre, Vincent; Melquiond, Guillaume; Revol, Nathalie; Torres, Serge

    2018-01-01

    This handbook is a definitive guide to the effective use of modern floating-point arithmetic, which has considerably evolved, from the frequently inconsistent floating-point number systems of early computing to the recent IEEE 754-2008 standard. Most of computational mathematics depends on floating-point numbers, and understanding their various implementations will allow readers to develop programs specifically tailored for the standard’s technical features. Algorithms for floating-point arithmetic are presented throughout the book and illustrated where possible by example programs which show how these techniques appear in actual coding and design. The volume itself breaks its core topic into four parts: the basic concepts and history of floating-point arithmetic; methods of analyzing floating-point algorithms and optimizing them; implementations of IEEE 754-2008 in hardware and software; and useful extensions to the standard floating-point system, such as interval arithmetic, double- and triple-word arithm...

  19. 13N species formed by proton irradiation of water

    International Nuclear Information System (INIS)

    Tilbury, R.S.; Dahl, J.R.

    1979-01-01

    We have shown that the irradiation of aerated water with 14.5-MeV protons produces as principal radioactive products nitrogen-13-labeled nitrate, nitrite, and ammonium ions. The yield of 13 NH 4 + varied from approximately 40% at low integrated dose (0.01 μAh) to 0.4% at high integrated dose (25 μAh), 13 NO 3 - varied from 50% at low dose to 85% at high dose. 13 N 2 - varied from 10% at low dose to 5% at high dose and 40% at intermediate doses. The results varied with recent use of target chamber. Induced radioactivity in the window foil was shown to have an effect on product composition. The effect of dissolved oxygen and certain additives (ethanol, ascorbic acid, formic acid, and ammonia) were investigated. In the absence of dissolved oxygen, or in the presence of ethanol, formic acid or ascorbic acid, almost pure 13 NH 3 could be produced at doses up to 2μAh. The data are explained by postulating the initial production of 13 NH 3 by successive abstraction of H atoms by the 13 NH 3 to HNO 2 and HNO 3

  20. Dosimetric comparison between proton and photon beams in the moving gap region in cranio-spinal irradiation (CSI)

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Chee-Wai; Das, Indra J.; Zhao, Li; Wolanski, Mark; Johnstone, Peter A.S.; Buchsbaum, Jeffrey C. [IU Health Proton Therapy Center, Bloomington (United States); Dept. of Radiation Oncology, Indiana Univ. School of Medicine, Indianapolis (United States)], e-mail: ccheng1@iuhealth.org; Srivastava, Shiv P. [Dept. of Radiation Oncology, Indiana Univ. School of Medicine, Indianapolis (United States); Dept. of Radiation Oncology, Reid Hospital, Richmond (United States); Simmons, Joseph [IU Health Proton Therapy Center, Bloomington (United States)

    2013-04-15

    Purpose: To investigate the moving gap region dosimetry in proton beam cranio-spinal irradiation (CSI) to provide optimal dose uniformity across the treatment volume. Material and methods: Proton beams of ranges 11.6 cm and 16 cm are used for the spine and the brain fields, respectively. Beam profiles for a 30 cm snout are first matched at the 50% level (hot match) on the computer. Feathering is simulated by shifting the dose profiles by a known distance two successive times to simulate a 2 x feathering scheme. The process is repeated for 2 mm and 4 mm gaps. Similar procedures are used to determine the dose profiles in the moving gap for a series of gap widths, 0-10 mm, and feathering step sizes, 4-10 mm, for a Varian iX 6MV beam. The proton and photon dose profiles in the moving gap region are compared. Results: The dose profiles in the moving gap exhibit valleys and peaks in both proton and photon beam CSI. The dose in the moving gap for protons is around 100% or higher for 0 mm gap, for both 5 and 10 mm feathering step sizes. When the field gap is comparable or larger than the penumbra, dose minima as low as 66% is obtained. The dosimetric characteristics for 6 MV photon beams can be made similar to those of the protons by appropriately combining gap width and feathering step size. Conclusion: The dose in the moving gap region is determined by the lateral penumbras, the width of the gap and the feathering step size. The dose decreases with increasing gap width or decreasing feathering step size. The dosimetric characteristics are similar for photon and proton beams. However, proton CSI has virtually no exit dose and is beneficial for pediatric patients, whereas with photon beams the whole lung and abdomen receive non-negligible exit dose.

  1. Study of charge transport in silicon detectors: Non-irradiated and irradiated

    International Nuclear Information System (INIS)

    Leroy, C.; Roy, P.; Casse, G.; Glaser, M.; Grigoriev, E.; Lemeilleur, F.

    1999-01-01

    The electrical characteristics of silicon detectors (standard planar float zone and MESA detectors) as a function of the particle fluence can be extracted by the application of a model describing the transport of charge carriers generated in the detectors by ionizing particles. The current pulse response induced by α and β particles in non-irradiated detectors and detectors irradiated up to fluences PHI ∼ 3 · 10 14 particles/cm 2 is reproduced via this model: i) by adding a small n-type region 15 μm deep on the p + side for the detectors at fluences beyond the n to p-type inversion and ii) for the MESA detectors, by considering one additional dead layer of 14 μm (observed experimentally) on each side of the detector, and introducing a second (delayed) component to the current pulse response. For both types of detectors, the model gives mobilities decreasing linearily up to fluences of about 5·10 13 particles/cm 2 and converging, beyond, to saturation values of about 1050 cm 2 /Vs and 450 cm 2 /Vs for electrons and holes, respectively. At a fluence PHI ∼ 10 14 particles/cm 2 (corresponding to about ten years of operation at the CERN-LHC), charge collection deficits of about 14% for β particles, 25% for α particles incident on the front and 35% for α particles incident on the back of the detector are found for both type of detectors

  2. SU-D-304-02: Magnetically Focused Proton Irradiation of Small Field Targets

    International Nuclear Information System (INIS)

    McAuley, GA; Slater, JM; Slater, JD; Wroe, AJ

    2015-01-01

    Purpose: To investigate the use of magnetic focusing for small field proton irradiations. It is hypothesized that magnetic focusing will provide significant dose distribution benefits over standard collimated beams for fields less than 10 mm diameter. Methods: Magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into hollow cylinders were designed and manufactured. Two focusing magnets were placed on a positioning track on our Gantry 1 treatment table. Proton beams with energies of 127 and 157 MeV, 15 and 30 mm modulation, and 8 mm initial diameters were delivered to a water tank using single-stage scattering. Depth dose distributions were measured using a PTW PR60020 diode detector and transverse profiles were measured with Gafchromic EBT3 film. Monte Carlo simulations were also performed - both for comparison with experimental data and to further explore the potential of magnetic focusing in silica. For example, beam spot areas (based on the 90% dose contour) were matched at Bragg depth between simulated 100 MeV collimated beams and simulated beams focused by two 400 T/m gradient magnets. Results: Preliminary experimental results show 23% higher peak to entrance dose ratios and flatter spread out Bragg peak plateaus for 8 mm focused beams compared with uncollimated beams. Monte Carlo simulations showed 21% larger peak to entrance ratios and a ∼9 fold more efficient dose to target delivery compared to spot-sized matched collimated beams. Our latest results will be presented. Conclusion: Our results suggest that rare earth focusing magnet assemblies could reduce skin dose and beam number while delivering dose to nominally spherical radiosurgery targets over a much shorter time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however expanded treatment sites can be also envisaged

  3. SU-D-304-02: Magnetically Focused Proton Irradiation of Small Field Targets

    Energy Technology Data Exchange (ETDEWEB)

    McAuley, GA; Slater, JM [Loma Linda University, Loma Linda, CA (United States); Slater, JD; Wroe, AJ [Loma Linda University Medical Center, Loma Linda, CA (United States)

    2015-06-15

    Purpose: To investigate the use of magnetic focusing for small field proton irradiations. It is hypothesized that magnetic focusing will provide significant dose distribution benefits over standard collimated beams for fields less than 10 mm diameter. Methods: Magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into hollow cylinders were designed and manufactured. Two focusing magnets were placed on a positioning track on our Gantry 1 treatment table. Proton beams with energies of 127 and 157 MeV, 15 and 30 mm modulation, and 8 mm initial diameters were delivered to a water tank using single-stage scattering. Depth dose distributions were measured using a PTW PR60020 diode detector and transverse profiles were measured with Gafchromic EBT3 film. Monte Carlo simulations were also performed - both for comparison with experimental data and to further explore the potential of magnetic focusing in silica. For example, beam spot areas (based on the 90% dose contour) were matched at Bragg depth between simulated 100 MeV collimated beams and simulated beams focused by two 400 T/m gradient magnets. Results: Preliminary experimental results show 23% higher peak to entrance dose ratios and flatter spread out Bragg peak plateaus for 8 mm focused beams compared with uncollimated beams. Monte Carlo simulations showed 21% larger peak to entrance ratios and a ∼9 fold more efficient dose to target delivery compared to spot-sized matched collimated beams. Our latest results will be presented. Conclusion: Our results suggest that rare earth focusing magnet assemblies could reduce skin dose and beam number while delivering dose to nominally spherical radiosurgery targets over a much shorter time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however expanded treatment sites can be also envisaged.

  4. Light yield of a CsI(Tl) crystal under irradiation by protons with the energy from 3 to 15 MeV

    International Nuclear Information System (INIS)

    Dorchoman, D.; Konstantin, M.; Lazarovich, D.; Muntyanu, I.; Oganesyan, K.O.; Porokhovoj, S.Yu.

    1976-01-01

    Measurement results are presented of light yield in CsI(Tl) crystals at the irradiation by protons with the energy from 3 to 15 MeV. Plates of 100x100x2 mm size are used as CsI(Tl) scintillator samples. A brief analysis of possible sistematic errors is given which allows to estimate the total error upon the light yield valve determination equal to 0,5%. Measurement results of crystal light yield show that the dependence of CsI(Tl) light yield on proton energy is described by the straight line passing through the origin

  5. Radiation damage and defect behavior in proton irradiated lithium-counterdoped n+p silicon solar cells

    Science.gov (United States)

    Stupica, John; Goradia, Chandra; Swartz, Clifford K.; Weinberg, Irving

    1987-01-01

    Two lithium-counterdoped n+p silicon solar cells with different lithium concentrations were irradiated by 10-MeV protons. Cell performance was measured as a function of fluence, and it was found that the cell with the highest concentration of lithium had the highest radiation resistance. Deep level transient spectroscopy which showed two deep level defects that were lithium related. Relating the defect energy levels obtained from this study with those from earlier work using 1-MeV electron irradiation shows no correlation of the defect energy levels. There is one marked similarity: the absence of the boron-interstitial-oxygen-interstitial defect. This consistency strengthens the belief that lithium interacts with oxygen to prevent the formation of the boron interstitial-oxygen interstitial defect. The results indicate that, in general, addition of lithium in small amounts to the p-base of a boron doped silicon solar cell such that the base remains p-type, tends to increase the radiation resistance of the cell.

  6. The detection of radiation defects by means of the Kossel effect investigated in proton-irradiated GaP

    International Nuclear Information System (INIS)

    Ullrich, H.J.; Rolle, S.; Geist, V.; Stephan, D.

    1984-01-01

    The line intensity of Ga-K/sub α/- and P-K/sub α/-Kossel reflections from GaP irradiated by 0.3 to 1.3 MeV protons in a wide dose range (10 14 to 5 x 10 17 cm -2 ) has been investigated. The excitation of the characteristic X-rays inside the crystal lattice has been performed either by 40 keV electrons or 1.3 MeV protons. It is established that, in contrast to the P-K/sub α/-lines, certain Ga-K/sub α/-reflections respond very sensitively to radiation defects, manifest as increase or decrease in line intensity. The reason is probably a modification of extinction effects caused by lattice defects. The different behaviour of these phenomena is discussed and an explanation proposed. The lattice disorder is determined by channeling backscattering measurements. (author)

  7. Studies of radiation damage in silicon sensors and a measurement of the inelastic proton--proton cross-section at 13 TeV

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00360674; Ward, Patricia

    This thesis presents studies of radiation damage in silicon sensors for the new ATLAS tracker at the high-luminosity LHC, calibrations of the LHC luminosity scale, and a measurement of the proton--proton inelastic cross-section at 13 TeV~with ATLAS data. The studies of radiation damage are performed by comparing sensor performance before and after irradiation, and include annealing studies. The measured quantities include: leakage current, depletion depth, inter-strip isolation, and charge collection. Surface and bulk damage is studied by comparing the results of sensors irradiated with protons and neutrons. The observed degradation of performance suggests the current sensor design will endure the radiation damage expected over the lifetime of the experiment at the high-luminosity LHC. The luminosity is calibrated for the proton--proton, proton--lead, and lead--lead collisions delivered by the LHC during 2013 and 2015. The absolute luminosity scale is derived with the van der Meer method. The systematic unc...

  8. Experimental study of pyrolytic boron nitride at high temperature with and without proton and VUV irradiations

    International Nuclear Information System (INIS)

    Balat-Pichelin, M.; Eck, J.; Heurtault, S.; Glénat, H.

    2014-01-01

    Highlights: • New results for the high temperature study of pBN in high vacuum for the heat shield of solar probes. • Physico-chemical behavior of pBN studied up to 1700 K with proton and VUV irradiations. • Rather low effect of synergistic aggressions on the microstructure of pBN material. • The α/ε ratio of pBN coating on C/C measured up to 2200 K is 20% lower than for the C/C itself. - Abstract: In the frame of future exploration missions such as Solar Probe Plus (NASA) and PHOIBOS (ESA), research was carried out to study pyrolytic BN material envisaged as coating for their heat shields. The physico-chemical behavior of CVD pBN at very high temperature with or without hydrogen ions and VUV (Vacuum Ultra-Violet) irradiations was studied in high vacuum together with the in situ measurement of the thermal radiative properties conditioning the thermal equilibrium of the heat shield. Experimental results obtained on massive pBN samples are presented through in situ mass spectrometry and mass loss rate, and post-test microstructural characterization by XRD, SEM, AFM and nano-indentation techniques, some of them leading to mechanical properties. It could be concluded that synergistic effect of high temperature, protons and VUV radiation has an impact on the emission of gaseous species, the mass loss rate and the mechanical properties of the material

  9. The Biological Effect of Fast Neutrons and High-Energy Protons

    International Nuclear Information System (INIS)

    Moskalev, Ju.I.; Petrovich, I.K.; Strel'cova, V.N.

    1964-01-01

    The paper gives the results of comparative experiments on the effects of fast neutrons and high-energy protons (500 MeV) on life expectancy, peripheral blood, incidence and rate of appearance of tumours in the rat as a function of administered dose and time of observation. The neutron experiment was performed on 573 and the proton experiment on 490 white rats. The animals irradiated with fast neutrons were given doses between 8.5 and 510 rad, and those irradiated with protons received doses between 28 and 1008 rad. The effective doses for the acute, sub-acute and chronic forms of sickness were established for fast neutrons and for protons. LD 50/30 for neutrons was 408 and for protons 600 rad, and the corresponding LD 50 / 120 values were 380 and 600 rad. The conditions governing rat mortality were analysed both in the early and the later stages of the experiment. It is shown that the average life expectancy of rats irradiated with fast neutrons does not depend on sex. The shape of the dose-effect curve for the various peripheral-blood indexes is strongly dependent not only on the radiosensitivity of the blood cells in question but also on the time of observation. It may change greatly in time for one and the same index. A considerable time after irradiation with either fast neutrons or protons, benign and malignant tumours appear in different tissues of the rats, including the haemopoeitic tissues, mammary glands, pituitary, uterus, ovaries, prostate gland, testicles, liver, kidneys, lungs, gastro-intestinal tract, subcutaneous tissue, lymph nodes, urinary bladder, etc. The over-all incidence of tumours and the number of cases of multi centred neoplasms in females are two to three times higher than in males. The minimum tumour dose for the mammary glands with neutron irradiation is apparently rather less than 42.5 rad. The maximum incidence of tumours of the pituitary is found after irradiation with a dose of 42.5 rad.- At this same dose leucosis and tumour of the

  10. Proton irradiation and endometriosis

    International Nuclear Information System (INIS)

    Wood, D.H.; Yochmowitz, M.G.; Salmon, Y.L.; Eason, R.L.; Boster, R.A.

    1983-01-01

    Female rhesus monkeys given single total-body exposures of protons of varying energies developed endometriosis at a frequency significantly higher than that of nonirradiated animals of the same age. The minimum latency period was 7 years after exposure. The doses and energies of the radiation received were within the range that could be received by an aircrew member in near-earth orbit during a random solar flare event, leading to the conclusion that endometriosis should be a consideration in assessing the risk of delayed radiation effects in female crewmembers

  11. Proton Beam Writing

    International Nuclear Information System (INIS)

    Rajta, I.; Szilasi, S.Z.; Csige, I.; Baradacs, E.

    2005-01-01

    Complete text of publication follows. Refractive index depth profile in PMMA due to proton irradiation Proton Beam Writing has been successfully used to create buried channel waveguides in PMMA, which suggested that proton irradiation increases the refractive index. To investigate this effect, PMMA samples were irradiated by 1.7-2.1 MeV proton beam. Spectroscopic Ellipsometry has been used to investigate the depth profile of the refractive index. An increase of the refractive index was observed in the order of 0.01, which is approximately one order of magnitude higher than the detection limit. The highest increase of the refractive index occurs at the end of range, i.e. we found a good correlation with the Bragg curve of the energy loss. Hardness changes in PMMA due to proton beam micromachining As protons penetrate a target material and lose their energy according to the Bragg curve, the energy loss is different at different depths. This causes depth-dependent changes of some physical properties in the target material (e.g. refractive index, hardness). In order to characterize the changes of hardness and other mechanical properties as a function of beam penetration depth, systematic investigations have been performed on PMMA, the most common resist material used in proton beam micromachining. Silicon check valve made by proton beam micromachining The possible application of Proton Beam Micromachining (PBM) has been demonstrated by a few authors for creating 3D Si microstructures. In this work we present alternative methods for the formation of a simple a non-return valve for microfluidic applications. Two different approaches have been applied, in both cases we exploited characteristic features of the PBM technique and the selective formation and dissolution of porous Si over the implantation damaged areas. In the first case we implanted 10 μm thick cantilever-type membrane of the valve normally to the crystal surface and at 30-60 degrees to the sidewalls of the

  12. Definitive proton beam radiation therapy for inoperable gastric cancer

    International Nuclear Information System (INIS)

    Shibuya, Susumu; Takase, Yasuhiro; Aoyagi, Hiroyuki; Orii, Kazuo; Sharma, N.; Iwasaki, Yoji; Tsujii, Hirohiko; Tsujii, Hiroshi.

    1991-01-01

    Proton beam radiation therapy using 250 MeV protons was carried out on two patients with early gastric cancer (T1, N0, M0). One patient was an 85-year-old man with early gastric cancer of type IIa + IIc. The other one was a 70-year-old man with early gastric cancer of type IIc. In both cases histological examination of biopsy specimens showed differential adenocarcinoma; distant metastasis was not found by other examinations. Both patients were considered inoperable due to their poor cardiac and/or respiratory functions. Therefore, it was decided to treat them by definitive proton irradiation, delivering total doses of 86 Gy and 83 Gy, respectively. In both patients, skin erythema that did not require any special treatment was found in the irradiation field. Hematobiological examinations did not show any abnormality. Although endoscopic examination at two years after irradiation in the former case and at seven months in the latter case showed persistent gastric ulcer at the site of the cancerous lesions, cancer cells were not found histologically. Therefore, we concluded that proton irradiation therapy was useful for inoperable early gastric cancers. (author)

  13. Concentration of floating biogenic material in convergence zones

    Science.gov (United States)

    Dandonneau, Yves; Menkes, Christophe; Duteil, Olaf; Gorgues, Thomas

    Some organisms that live just below the sea surface (the neuston) are known more as a matter of curiosity than as critical players in biogeochemical cycles. The hypothesis of this work is that their existence implies that they receive some food from an upward flux of organic matter. The behaviour of these organisms and of the associated organic matter, hereafter mentioned as floating biogenic material (FBM) is explored using a global physical-biogeochemical coupled model, in which its generation is fixed to 1% of primary production, and decay rate is of the order of 1 month. The model shows that the distribution of FBM should depart rapidly from that of primary production, and be more sensitive to circulation patterns than to the distribution of primary production. It is trapped in convergence areas, where it reaches concentrations larger by a factor 10 than in divergences, thus enhancing and inverting the contrast between high and low primary productivity areas. Attention is called on the need to better understand the biogeochemical processes in the first meter of the ocean, as they may impact the distribution of food for fishes, as well as the conditions for air-sea exchange and for the interpretation of sea color.

  14. Effects of electron and proton irradiations on n/p and p/n GaAs cells grown by MOCVD

    International Nuclear Information System (INIS)

    Weinberg, I.; Swartz, C.K.; Hart, R.E. Jr.

    1987-01-01

    State-of-the-art n/p and p/n heteroface GaAs cells, processed by metal organic chemical vapor deposition, were irradiated by 1 MeV electrons and 37 MeV protons and their performance determined as a function of fluence. It was found that the p/n cells were more radiation resistant than the n/p cells. The increased loss in the n/p cells was attributed to increases in series resistance and losses in the p-region resulting from the irradiation. The greater loss in fill factor observed for the n/p cells introduces the possibility that the presently observed superiority of the p/n cells may not be an intrinsic property of this configuration in GaAs

  15. Proton-Induced Conductivity Enhancement in AlGaN/GaN HEMT Devices

    Science.gov (United States)

    Lee, In Hak; Lee, Chul; Choi, Byoung Ki; Yun, Yeseul; Chang, Young Jun; Jang, Seung Yup

    2018-04-01

    We investigated the influence of proton irradiation on the AlGaN/GaN high-electron-mobility transistor (HEMT) devices. Unlike previous studies on the degradation behavior upon proton irradiation, we observed improvements in their electrical conductivity and carrier concentration of up to 25% for the optimal condition. As we increased the proton dose, the carrier concentration and the mobility showed a gradual increase and decrease, respectively. From the photoluminescence measurements, we observed a reduction in the near-band-edge peak of GaN ( 366 nm), which correlate on the observed electrical properties. However, neither the Raman nor the X-ray diffraction analysis showed any changes, implying a negligible influence of protons on the crystal structures. We demonstrated that high-energy proton irradiation could be utilized to modify the transport properties of HEMT devices without damaging their crystal structures.

  16. A model of disordered zone formation in Cu3Au under cascade-producing irradiation

    International Nuclear Information System (INIS)

    Kapinos, V.G.; Bacon, D.J.

    1995-01-01

    A model to describe the disordering of ordered Cu 3 Au under irradiation is proposed. For the thermal spike phase of a displacement cascade, the processes of heat evolution and conduction in the cascade region are modelled by solving the thermal conduction equation by a discretization method for a medium that can melt and solidify under appropriate conditions. The model considers disordering to result from cascade core melting, with the final disordered zone corresponding to the largest molten zone achieved. The initial conditions for this treatment are obtained by simulation of cascades by the MARLOWE code. The contrast of disordered zones imaged in a superlattice dark-field reflection and projected on the plane parallel to the surface of a thin foil was calculated. The average size of images from hundreds of cascades created by incident Cu + ions were calculated for different ion energies and compared with experimental transmission electron microscopy data. The model is in reasonable quantitative agreement with the experimentally observed trends. (author)

  17. Suitability of some common polymer films for MeV proton beam dosimetry

    International Nuclear Information System (INIS)

    Makkonen-Craig, S.; Paronen, M.; Arstila, K.; Helariutta, K.; Rauhala, E.; Tikkanen, P.

    2005-01-01

    We have been evaluating the efficacy of polymer films for proton beam dosimetry. PE, PS, PVF, PVDF, PFA and FEP films were irradiated with 4.1 and 9.4 MeV protons at a flux of 2.5 x 10 11 cm -2 s -1 and a fluence of 2.5 x 10 13 cm -2 . The perfluorinated films were relatively insensitive to the proton irradiation. The UV absorption of PS displayed significant radiation-induced red shift, but no quantifiable absorption peaks. The strongly absorbing chromophore at 225 nm of irradiated PVDF is too unstable for practical dosimetry. PE has a stable and moderately absorbing radiolytic chromophore at 235 nm, but is transparent in the visible wavelength region. Irradiated PVF absorbs strongly in both UV and visible regions, and its UV absorbance is linearly proportional to the dose over the range of 10-1000 kGy when irradiated with 4.1 MeV protons at a dose rate of 840 Gy s -1 . PVF shows the most potential as multipurpose dosimeter for high resolution profiling of ion beams. Pertinent applications include irradiations that require verification of lateral beam homogeneity

  18. Dielectric characterization of low-loss calcium strontium titanate fibers produced by laser floating zone technique for wireless communication

    International Nuclear Information System (INIS)

    Amaral, F.; Valente, M.A.; Costa, L.C.; Costa, F.M.

    2014-01-01

    Wireless communication technology assisted to a huge development during the last two decades, responding to the growing demand for small size and low weight devices such as cell phones and global positioning systems. The need for miniaturization and higher autonomy resulted in the development of new dielectric oxide ceramics with very specific properties, to be applied as dielectric resonators in filters, oscillators, and antennas. Some crucial properties as a high quality factor, high dielectric constant, and near zero temperature coefficient of resonant frequency must be considered during the selection of the appropriate materials. The present work deals with the preparation of calcium titanate (CaTiO 3 ), strontium titanate (SrTiO 3 ), and calcium strontium titanate (Ca x Sr 1-x TiO 3 ) fibers produced by laser floating zone (LFZ) technique. Our results show that fibers grown at lower pulling rates exhibit higher ε', for all the studied frequency range, including the microwave region. Moreover, the quality factor is always high envisaging the possibility to include these materials in future wireless device applications. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Dielectric characterization of low-loss calcium strontium titanate fibers produced by laser floating zone technique for wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, F. [Department of Physics and I3N, University of Aveiro, 3810-193, Aveiro (Portugal); Polytechnic Institute of Coimbra, 3000-271, Coimbra (Portugal); Valente, M.A.; Costa, L.C.; Costa, F.M. [Department of Physics and I3N, University of Aveiro, 3810-193, Aveiro (Portugal)

    2014-09-15

    Wireless communication technology assisted to a huge development during the last two decades, responding to the growing demand for small size and low weight devices such as cell phones and global positioning systems. The need for miniaturization and higher autonomy resulted in the development of new dielectric oxide ceramics with very specific properties, to be applied as dielectric resonators in filters, oscillators, and antennas. Some crucial properties as a high quality factor, high dielectric constant, and near zero temperature coefficient of resonant frequency must be considered during the selection of the appropriate materials. The present work deals with the preparation of calcium titanate (CaTiO{sub 3}), strontium titanate (SrTiO{sub 3}), and calcium strontium titanate (Ca{sub x}Sr{sub 1-x}TiO{sub 3}) fibers produced by laser floating zone (LFZ) technique. Our results show that fibers grown at lower pulling rates exhibit higher ε', for all the studied frequency range, including the microwave region. Moreover, the quality factor is always high envisaging the possibility to include these materials in future wireless device applications. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Study of the effects of high-energy proton beams on escherichia coli

    Science.gov (United States)

    Park, Jeong Chan; Jung, Myung-Hwan

    2015-10-01

    Antibiotic-resistant bacterial infection is one of the most serious risks to public health care today. However, discouragingly, the development of new antibiotics has progressed little over the last decade. There is an urgent need for alternative approaches to treat antibiotic-resistant bacteria. Novel methods, which include photothermal therapy based on gold nano-materials and ionizing radiation such as X-rays and gamma rays, have been reported. Studies of the effects of high-energy proton radiation on bacteria have mainly focused on Bacillus species and its spores. The effect of proton beams on Escherichia coli (E. coli) has been limitedly reported. Escherichia coli is an important biological tool to obtain metabolic and genetic information and is a common model microorganism for studying toxicity and antimicrobial activity. In addition, E. coli is a common bacterium in the intestinal tract of mammals. In this research, the morphological and the physiological changes of E. coli after proton irradiation were investigated. Diluted solutions of cells were used for proton beam radiation. LB agar plates were used to count the number of colonies formed. The growth profile of the cells was monitored by using the optical density at 600 nm. The morphology of the irradiated cells was observed with an optical microscope. A microarray analysis was performed to examine the gene expression changes between irradiated samples and control samples without irradiation. E coli cells have observed to be elongated after proton irradiation with doses ranging from 13 to 93 Gy. Twenty-two were up-regulated more than twofold in proton-irradiated samples (93 Gy) compared with unexposed one.