WorldWideScience

Sample records for programmable syringe pump

  1. Low-Cost Touchscreen Driven Programmable Dual Syringe Pump for Life Science Applications

    OpenAIRE

    Liu, Jamin; Garcia, Valentina; Derisi, Joseph

    2018-01-01

    Syringe pumps are powerful tools able to automate routine laboratory practices that otherwise consume large amounts of manual labor time. Commercially available syringe pumps are expensive, difficult to customize, and often preset for a narrow range of operations. Here, we show how to build a programmable dual syringe pump (PDSP) that overcomes these limitations. The PDSP is driven by a Raspberry Pi paired with a stepper motor controller to allow maximal customization via Python scripting. Th...

  2. Portable system of programmable syringe pump with potentiometer for determination of promethazine in pharmaceutical applications.

    Science.gov (United States)

    Saleh, Tawfik A; Abulkibash, A M; Ibrahim, Atta E

    2012-04-01

    A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective.

  3. Open-Source Syringe Pump Library

    Science.gov (United States)

    Wijnen, Bas; Hunt, Emily J.; Anzalone, Gerald C.; Pearce, Joshua M.

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications. PMID:25229451

  4. Large volume syringe pump extruder for desktop 3D printers

    Directory of Open Access Journals (Sweden)

    Kira Pusch

    2018-04-01

    Full Text Available Syringe pump extruders are required for a wide range of 3D printing applications, including bioprinting, embedded printing, and food printing. However, the mass of the syringe becomes a major challenge for most printing platforms, requiring compromises in speed, resolution and/or volume. To address these issues, we have designed a syringe pump large volume extruder (LVE that is compatible with low-cost, open source 3D printers, and herein demonstrate its performance on a PrintrBot Simple Metal. Key aspects of the LVE include: (1 it is open source and compatible with open source hardware and software, making it inexpensive and widely accessible to the 3D printing community, (2 it utilizes a standard 60 mL syringe as its ink reservoir, effectively increasing print volume of the average bioprinter, (3 it is capable of retraction and high speed movements, and (4 it can print fluids using nozzle diameters as small as 100 μm, enabling the printing of complex shapes/objects when used in conjunction with the freeform reversible embedding of suspended hydrogels (FRESH 3D printing method. Printing performance of the LVE is demonstrated by utilizing alginate as a model biomaterial ink to fabricate parametric CAD models and standard calibration objects. Keywords: Additive manufacturing, 3D bioprinting, Embedded printing, FRESH, Soft materials extrusion

  5. The effectiveness and safety of syringe vending machines as a component of needle syringe programmes in community settings.

    Science.gov (United States)

    Islam, Mofizul; Wodak, Alex; Conigrave, Katherine M

    2008-12-01

    Syringe vending machines (SVMs) have been introduced in Europe and Australasia as part of the effort to increase the availability of sterile needles and syringes to injecting drug users (IDUs). This qualitative review of 14 published and grey literature studies examines whether community-based SVMs as a component of a comprehensive needle syringe programme (NSP) assist to reduce the spread of HIV and other blood-borne viruses amongst IDUs. The available evidence suggests that SVMs increase access to sterile injecting equipment, reduce needle and syringe sharing, and are likely to be cost efficient. SVMs also complement other modes of NSP delivery as they are used by IDUs who are less likely to attend staffed NSPs or pharmacies. If installed and properly maintained in a well-chosen location and with the local community well prepared, SVMs can enhance the temporal and geographical availability of sterile injecting equipment.

  6. Dump the pump: manual aspiration thrombectomy (MAT) with a syringe is technically effective, expeditious, and cost-efficient.

    Science.gov (United States)

    Gross, Bradley A; Jadhav, Ashutosh P; Jovin, Tudor G; Jankowitz, Brian Thomas

    2018-04-01

    Syringe aspiration for manual aspiration thrombectomy (MAT) is a cost- and time-efficient alternative to an aspiration pump with likely similar efficacy. It is counterintuitive to expect the pump to perform better than direct vacuum with a syringe, as the pump must deliver vacuum additionally through a canister and meters of tubing. To present in vitro and clinical results of MAT with a syringe. An in vitro analysis was performed comparing vacuum pressures generated by syringe aspiration and with pump aspiration. This was then complemented with prospective clinical data providing details of angiographic and clinical outcomes for syringe MAT. The in vitro analysis demonstrated that equal to slightly greater vacuum pressures were generated by a 60 cc syringe as compared with the pump in both static and partial flow conditions. In our clinical series, 106/113 acute stroke thrombectomies over a 6-month period were performed with syringe MAT on the first pass. Syringe usage instead of pump tubing and a canister led to a total savings of $58 300. The rate of Thrombolysis in Cerebral Infarction 2b/3 recanalization was 93%. Adjunctive stentriever usage was performed in 23% of cases. Median puncture to reperfusion time was 25 min; mean change in National Institute of Health Stroke Scale score at 24 hours was an improvement of 5.1 (median 6). The in-hospital mortality rate was 10%. Seventy percent of patients were discharged to home (modified Rankin Scale (mRS) score 0-2) or a rehabilitation facility (mRS score 2-4). MAT using a syringe is a safe, fast, and more cost-effective approach than using an aspiration pump. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  8. Costs of a Hospital-Based, Ready-To-Use Syringe Delivery Programme

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Vand, S; Lisby, M

    2017-01-01

    %) and at €20,905 (an increase of 228%) for the endoscopy department. The ready-to-use delivery program imposed an additional cost of €11.32 per day surgery operation and €2.41 per endoscopy procedure. Conclusion: This ready-to-use programme increased the cost of the medical handling process. This incremental......Objective: The risk of errors in the medication administration process is high. Applications of pre lled syringes may improve patient safety but could be more costly. The objective of this study was to assess the additional costs of a ready-to-use syringe delivery programme in comparison...... with a conventional delivery programme at day surgery and endoscopy departments at a large university hospital. Methods: The cost analysis used the hospital perspective and developed an “activity-based costing” model to assess the costs of medicine- handling activities. The model was calibrated with six-month data...

  9. A sophisticated programmable miniaturised pump for insulin delivery.

    Science.gov (United States)

    Klein, J C; Slama, G

    1980-09-01

    We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.

  10. Analysis of event logs from syringe pumps: a retrospective pilot study to assess possible effects of syringe pumps on safety in a university hospital critical care unit in Germany.

    Science.gov (United States)

    Kastrup, Marc; Balzer, Felix; Volk, Thomas; Spies, Claudia

    2012-07-01

    Medication errors occur in approximately one out of five doses in a typical hospital setting. Patients in the intensive care unit (ICU) are particularly susceptible to errors during the application of intravenous drugs as they receive numerous potent drugs applied by syringe pumps. The aim of this study was to analyse the effects on potential harmful medication errors and to address factors that have potential for improving medication safety after the introduction of a standardized drug library into syringe pumps with integrated decision support systems. A team of physicians and nurses developed a dataset that defined standardized drug concentrations, application rates and alert limits to prevent accidental overdosing of intravenous medications. This dataset was implemented in 100 syringe pumps with the ability to log programming errors, alerts, reprogramming events and overrides ('smart pumps'). In this retrospective pilot study, all pump-related transaction data were obtained from the pump logs, by downloading the data from the pumps, covering 20 months of use between 1 April 2008 and 30 November 2009. Patient data were gathered from the electronic patient charts. The study was performed in a cardiothoracic ICU of the Charité University Hospital, Berlin, Germany. A total of 7884 patient treatment days and 133,601 infusion starts were evaluated. The drug library with the features of the dose rate was used in 92.8% of the syringe pump starts, in 1.5% of the starts a manual dosing mode without the use of the drug library was used and in 5.7% of the starts the mode 'mL/h', without any calculation features, was used. The most frequently used drugs were vasoactive drugs, followed by sedation medication. The user was alerted for a potentially harmful overdosing in 717 cases and in 66 cases the pumps were reprogrammed after the alert. During the early morning hours a higher rate of alarms was generated by the pumps, compared with the rest of the day. Syringe pumps with

  11. A two-stage procedure for determining unsaturated hydraulic characteristics using a syringe pump and outflow observations

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Jensen, Karsten Høgh; Hollenbeck, Karl-Josef

    1997-01-01

    A fast two-stage methodology for determining unsaturated flow characteristics is presented. The procedure builds on direct measurement of the retention characteristic using a syringe pump technique, combined with inverse estimation of the hydraulic conductivity characteristic based on one......-step outflow experiments. The direct measurements are obtained with a commercial syringe pump, which continuously withdraws fluid from a soil sample at a very low and accurate how rate, thus providing the water content in the soil sample. The retention curve is then established by simultaneously monitoring......-step outflow data and the independently measured retention data are included in the objective function of a traditional least-squares minimization routine, providing unique estimates of the unsaturated hydraulic characteristics by means of numerical inversion of Richards equation. As opposed to what is often...

  12. The impact of citrate introduction at UK syringe exchange programmes: a retrospective cohort study in Cheshire and Merseyside, UK

    Directory of Open Access Journals (Sweden)

    Wareing Michelle

    2007-12-01

    Full Text Available Abstract Background In 2003, it became legal in the UK for syringe exchange programmes (SEPs to provide citrate to injecting drug users to solubilise heroin. Little work has been undertaken on the effect of policy change on SEP function. Here, we examine whether the introduction of citrate in Cheshire and Merseyside SEPs has altered the number of heroin/crack injectors accessing SEPs, the frequency at which heroin/crack injectors visited SEPs and the number of syringes dispensed. Methods Eleven SEPs in Cheshire and Merseyside commenced citrate provision in 2003. SEP-specific data for the six months before and six months after citrate was introduced were extracted from routine monitoring systems relating to heroin and crack injectors. Analyses compared all individuals attending pre and post citrate and matched analyses only those individuals attending in both periods (defined as 'longitudinal attenders'. Non-parametric tests were used throughout. Results Neither new (first seen in either six months period nor established clients visited SEPs more frequently post citrate. New clients collected significantly less syringes per visit post citrate, than pre citrate (14.5,10.0; z = 1.992, P Conclusion The introduction of citrate did not negatively affect SEP attendance. 'Longitudinal attenders' visited SEPs more frequently post citrate, providing staff with greater opportunity for intervention and referral. As the number of syringes they collected each visit remained unchanged the total number of clean syringes made available to this group of injectors increased very slightly between the pre and post citrate periods. However, new clients collected significantly less syringes post citrate than pre citrate, possibly due to staff concerns regarding the amount of citrate (and thus syringes to dispense safely to new clients. These concerns should not be allowed to negatively impact on the number of syringes dispensed.

  13. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later

  14. Needle syringe programmes and opioid substitution therapy for preventing hepatitis C transmission in people who inject drugs

    Science.gov (United States)

    Platt, Lucy; Minozzi, Silvia; Reed, Jennifer; Vickerman, Peter; Hagan, Holly; French, Clare; Jordan, Ashly; Degenhardt, Louisa; Hope, Vivian; Hutchinson, Sharon; Maher, Lisa; Palmateer, Norah; Taylor, Avril; Bruneau, Julie; Hickman, Matthew

    2017-01-01

    Background Needle syringe programmes and opioid substitution therapy for preventing hepatitis C transmission in people who inject drugs Needle syringe programmes (NSP) and opioid substitution therapy (OST) are the primary interventions to reduce hepatitis C (HCV) transmission in people who inject drugs. There is good evidence for the effectiveness of NSP and OST in reducing injecting risk behaviour and increasing evidence for the effectiveness of OST and NSP in reducing HIV acquisition risk, but the evidence on the effectiveness of NSP and OST for preventing HCV acquisition is weak. Objectives To assess the effects of needle syringe programmes and opioid substitution therapy, alone or in combination, for preventing acquisition of HCV in people who inject drugs. Search methods We searched the Cochrane Drug and Alcohol Register, CENTRAL, the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), MEDLINE, Embase, PsycINFO, Global Health, CINAHL, and the Web of Science up to 16 November 2015. We updated this search in March 2017, but we have not incorporated these results into the review yet. Where observational studies did not report any outcome measure, we asked authors to provide unpublished data. We searched publications of key international agencies and conference abstracts. We reviewed reference lists of all included articles and topic-related systematic reviews for eligible papers. Selection criteria We included prospective and retrospective cohort studies, cross-sectional surveys, case-control studies and randomised controlled trials that measured exposure to NSP and/or OST against no intervention or a reduced exposure and reported HCV incidence as an outcome in people who inject drugs. We defined interventions as current OST (within previous 6 months), lifetime use of OST and high NSP coverage (regular attendance at

  15. Syringe sociology.

    Science.gov (United States)

    Vitellone, Nicole

    2015-06-01

    In this article I consider the impact of social epistemologies for understanding the object of the syringe. My aim is to examine the process through which the syringe transforms from an injecting device to a tool of social and political inquiry. Paying particular attention to the uses of Foucault, Becker, Bourdieu, Freud and Latour in empirical studies of injecting heroin use, I examine the sociology of the syringe through the lens of habit and habitus, discourse and deviance, mourning and melancholia, attachment and agencement. In pursuing the theory behind the object my goal is to address a sociological object in the making. In so doing I show how the syringe has been significant for social research, social theory, and sociology. It is the difference the object makes that this article seeks to describe. In tracing the epistemology of the syringe I show how the object is important not just for knowledge of addiction but sociology itself. © London School of Economics and Political Science 2015.

  16. Exploring stakeholder perceptions of acceptability and feasibility of needle exchange programmes, syringe vending machines and safer injection facilities in Tijuana, Mexico.

    Science.gov (United States)

    Philbin, Morgan M; Mantsios, Andrea; Lozada, Remedios; Case, Patricia; Pollini, Robin A; Alvelais, Jorge; Latkin, Carl A; Magis-Rodriguez, Carlos; Strathdee, Steffanie A

    2009-07-01

    Injection drug use is a growing public health crisis along the U.S.-Mexican border and rising rates of blood-borne infections highlight the pressing need for harm reduction interventions. We explored the acceptability and feasibility of such interventions in Tijuana, a city adjacent to San Diego, California. Using in-depth qualitative interviews conducted from August 2006-March 2007 with 40 key stakeholders - pharmacists, legal professionals, health officials, religious officials, drug treatment providers, and law enforcement personnel - we explored the acceptability and feasibility of interventions to reduce drug-related harm in Tijuana, Mexico. Interviews were taped with consent, transcribed verbatim, and translated. Content analysis was conducted to identify themes which included barriers, structural limitations, and suggestions for implementation. Topics included acceptance and feasibility of needle exchange programmes (NEPs), syringe vending machines, and safer injection facilities (SIFs), structural barriers and suggestions for implementation. Of these interventions, NEPs were deemed the most acceptable (75%); however, only half believed these could be feasibly implemented, citing barriers involving religion, police, and lack of political will, public awareness, and funding. Increasing HIV infection rates among injection drug users in Tijuana have prompted interest in public health responses. Our results may assist policy strategists in implementing social-structural interventions that will help create enabling environments that facilitate the scale-up and implementation of harm reduction in Tijuana.

  17. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. ITER-FEAT vacuum pumping and fuelling R and D programmes

    International Nuclear Information System (INIS)

    Murdoch, D.K.; Antipenkov, A.; Ladd, P.; Boissin, J.-C.; Day, C.; Haas, H.; Mack, A.; Pimanikhin, S.; Saksagansky, G.; Viniar, I.

    2001-01-01

    The design of the ITER-FEAT vacuum pumping and fuelling systems is supported by two key R and D programs, the first directed towards the development of a steady state tritium compatible pellet injector, and the second towards the development of a supercritical helium cooled cryogenic pump for torus exhaust. While the pellet injector programme for ITER-FEAT is new, that for the cryopump has evolved from a programme that originally supported the 1998 ITER design. As the plasma exhaust parameters have remained essentially unchanged between these two machines, the R and D conducted to date remains valid. Initial test results on the prototype injector, TPI-1, which included continuous injection of 3 mm hydrogen pellets at 500 m/s and at 1 to 2 Hz for periods up to, are reported. A model of the cryopump has now been installed in a new dedicated test bed at the Karlsruhe Research Centre where acceptance tests have been completed and preliminary results from pumping tests obtained. An extensive test campaign to fully characterise pump performance and identify any mechanical details which require modification has started. (author)

  19. Norwegian participation in the IEA Heat Pump Programme Annex 34 - final report

    Energy Technology Data Exchange (ETDEWEB)

    Nordtvedt, S.R.

    2012-07-01

    This report is the Norwegian team contribution to Task A within the IEA Heat Pumps Programme Annex 34 on #Left Double Quotation Mark#Thermally driven heat pumps#Right Double Quotation Mark#. It aims to give an overview of the thermally driven heat pump (TDHP) and chiller (TDC) market, recent developments in the area of TDHP and TDC, as well as to give an outlook of the progress of this technology. There are no Norwegian manufacturers on the TDHP market. There are only seven existing thermally driven absorption system installations in Norway. Three are district heat driven water/LiBr chillers, one is a steam driven water/LiBr chiller, one water/LiBr heat pump for flue gas condensation in a wood chip heating unit, and two gas driven ammonia-water chillers. The future market for thermally driven heat pumps and chillers in Norway is expected to be in combination of biomass, district heat or waste heat. (Author)

  20. [Morphine self-administration by rats using a pneumatic syringe].

    Science.gov (United States)

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  1. Norwegian participation in IEA Heat Pump Programme Annex 29 - final report

    International Nuclear Information System (INIS)

    Stene, Joern

    2006-06-01

    Ground source heat is a collective name for tapping, recharging and storing thermal energy at moderate temperature in the bedrock, ground water and soil (renewable energy). By means of heat pumps, ground source heating systems can be used as highly energy efficient and environmentally-friendly heating and cooling in all kinds of buildings. IEA's heat pump programme (IEA HPP) has in the period March 2004 to June 2006 carried out an Annex on heating pump systems based on ground source heat: 'Annex 29 - Ground-source heat pumps overcoming market and technical barriers'. The project has i.a. covered the development of more cost- and energy efficient solutions, identification and analysis of market obstacles, technology transfer and the task of making visible the energy economising potential and environmental gains that this type of systems represent. The six participating countries have been Canada, Japan, Norway, Sweden, USA and Austria (operating agent). Norway's participation in IEA Annex 29 has been financed by ENOVA SF, while SINTEF Energy research AS has been in charge of planning and executing the Norwegian project activities. This report provides a general presentation of ground source heat pump systems, and gives a summary of the most important Norwegian activities in IEA Annex 29, which includes: The development of a Norwegian internet home page (http://www.energy.sintef.no/prosjekt/annex29), preparation of Norwegian status report, initiation, coordination and carrying out of Norwegian research projects and reports, communication of results (technology transfer) in Norway, networking activities towards important market actors in Norway, participation and delivering discourse at international seminars (workshops), and participation at international working sessions (ml)

  2. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  3. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  4. Fasting in Ramadan with an insulin pump.

    Science.gov (United States)

    Kesavadev, Jothydev

    2015-05-01

    A good majority of subjects with diabetes on insulin therapies observe fasting during Ramadan. The challenge for the physician and the patient is to manage diabetes without an interruption to fasting by avoiding hypoglycaemia and simultaneously ensuring that blood glucose remain at acceptable safe levels. Insulin Pumps differ from syringes and insulin pens in that it offers a variable basal rate, different type of boluses and associated calculators. The technological advances that pumps offer, help educated subjects pre-programme a reduced basal rate throughout the day. Pumps ensure avoidance of hypoglycaemia and hyperglycaemia and preserve quality of life and enhance confidence in patients during fasting. Due to multiple benefits, insulin pumps are considered the best delivery systems for insulin during the holy month of Ramadan, despite the prerequisites for its optimal output and cost concerns.

  5. Aquagenic syringeal acrokeratoderma

    Directory of Open Access Journals (Sweden)

    Belkiz Uyar

    2014-01-01

    Full Text Available Aquagenic syringeal acrokeratoderma is a rare, transient, and usually bilaterally symmetric, palmoplantar keratoderma. Patients complain of tingling and pain in the hands starting a few minutes after exposure to water and lasting for 20-30 minutes after removal. Clinically, there is marked wrinkling with edematous white papules on the palms or, less often, the soles. We present the case of a 21-year-old woman who used spironolactone for polycystic ovary syndrome and had similar clinical features 2 weeks later, after withdrawing the drug.

  6. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  7. Drug residues in used syringes in Switzerland: A comparative study.

    Science.gov (United States)

    Lefrançois, Elodie; Augsburger, Marc; Esseiva, Pierre

    2018-05-01

    Harm reduction services, including needle-exchange programmes, have been implemented in Switzerland for over 20 years. Their main aim is to lessen the negative social and/or physical consequences associated with illicit drug consumption and, therefore, improve prevention messages. To this end, knowledge of illicit drug consumption practices is necessary. Periodic self-report surveys are the primary source of data for monitoring drug users' behaviour. Analysis of residual content of used syringes can bring further and objective knowledge about consumed products through analytically confirmed data. Used syringes were sampled in 2 syringe-exchange facilities in Lausanne. These structures are a bus where the users bring back their syringes (ABS) and an automatic injecting kit dispenser (AIKD). Once syringes were collected, a validated gas chromatography-mass spectrometry (GC-MS) method was implemented in order to detect drugs (licit or illicit) contained in the residual content of used syringes. Cocaine was the most common drug detected alone (39% in ABS and 31% in AIKD), followed by the simultaneous detection of heroin and cocaine (12% and 17%) and heroin and midazolam (12% and 17%). The differences between the illicit drugs distribution of used syringes collected in AIKD and ABS were not statistically significant. Analysis of residual content of used syringes as a monitoring tool is an original approach that has already led to a better understanding of the habits of drug-injection users. Over the long term, this approach is a powerful tool to track and detect new consumption practices in a quasi-real-time. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  9. Gas ampoule-syringe

    International Nuclear Information System (INIS)

    Gay, D.D.

    1986-01-01

    This patent describes disposable gas ampoule holding or containing a gas such as a radioactive gas, comprising: (a) a cylindrical glass tube which is adapted to hold the gas; (b) a layer of absorbent material which circumscribes and which contacts cylindrical glass tube (a) which absorbs the gas; (c) a plastic tube, which circumscribes and contacts absorbent material layer (b) and which is externally threaded on each of its end portions; (d) a cap, which is threaded onto a first end of plastic tube (c); (e) a cylindrical block, which is positioned in the first end of cylindrical glass tube (a) adjacent to cap (d), which contacts cylindrical glass tube (a), which is composed of a foamed material and which is impregnated with a gas adsorbent material; (f) a cylindrical plunger tip, which is located in the first end of cylindrical glass tube (a) in a gas-tight manner adjacent to cylindrical block (e); (g) an end stopper, which has a central cylindrical shaft that is positioned in the second end of cylindrical glass tube (a); and (h) a cap, which is threaded onto the second end of plastic tube (e). A combination of the disposable gas ampoule and syringe adapted to operably interface with the gas ampoule is also described

  10. Programme

    OpenAIRE

    Hobday, E, fl. 1905, artist

    2003-01-01

    A photograph of an illustrated programme listing dances. The illustration shows a snake charmer playing to a snake while another man watches. Buildings and trees can be seen behind a wall in the distance. In the lower right-hand corner of the programme is the signature 'E. Hobday'. The programme is almost certainly related to the Punjab Ball, Lahore. It is placed next to the Punjab Ball Menu in the album and the Menu is also illustrated by 'E. Hobday'.

  11. The benefits and drawbacks of syringe drivers in palliative care.

    Science.gov (United States)

    Costello, John; Nyatanga, Brian; Mula, Carole; Hull, Jenny

    2008-03-01

    This article will outline the use of continuous subcutaneous infusion pumps, known as syringe drivers, including their benefits and drawbacks in a palliative care context. There have been over 5000 articles published globally describing syringe drivers in the medical and nursing literature within the last decade. Many provide guidance on their use, although much of the data are repetitious, disease or age-group specific, and focused on pragmatic issues to do with clinical application. Several trusts and hospices across the UK are carrying out trials of the recently launched McKinley T34 syringe driver. Therefore, it seems timely to consider their wider use internationally. Globally, practitioners in palliative care are very familiar with their use, although the literature lacks specific guidance and, at times, the information is ambiguous. Having briefly reviewed their benefits, the article considers the limitations of using syringe drivers and comments on some of the lesser known/reported practical and patient-focused drawbacks associated with their use. We conclude by considering why, when so much education and training exists to help practitioners use these devices effectively, so many human errors occur.

  12. A computer-controlled syringe driver for use during anaesthesia. A modification of the Graseby MS16A.

    Science.gov (United States)

    Cohen, A T

    1986-06-01

    The requirements of a drug infusion device for use in theatre are discussed. A modification of the Graseby MS16A syringe pump and an interface circuit permitting its remote control by microcomputer are described. The pump is controlled via a standard computer interface (RS232) which makes it a unique and powerful research tool. Aspects of safety are considered.

  13. Extractables and leachables considerations for prefilled syringes.

    Science.gov (United States)

    Jenke, Dennis R

    2014-10-01

    Use of pre-filled syringes as both a packaging and delivery system for pharmaceutical drug products is accelerating. Pre-filled syringes must meet the quality and suitability for use requirements for both systems, including compatibility with the drug product. Relevant incompatibilities between pre-filled syringes and drug products include the safety of syringe-based leachables that accumulate in drug products and the ability of leachables to interact with the drug product's ingredients as such interactions can affect safety, efficacy, stability and physical viability. Relevant suitability considerations for pre-filled syringes are discussed herein and specific examples of suitability for use issues for pre-filled syringes are cited, focusing on extractables associated with pre-filled syringes and leachables derived from such syringes. Aspects considered include the toxicological impact of leachables, their ability to alter the efficacy of drug products and to produce other undesirable outcomes such as aggregation and immunogenic responses. Materials used in pre-filled syringes and the conditions of use minimize the traditional safety risk associated with leachables. However, drug products that use pre-filled syringes are prone to non-traditional interactions such as disruption of protein conformation, leading to potential efficacy, safety and quality issues. In order to qualify pre-filled syringes for use, the traditional approach of measuring extractables and leachables and inferring their effect must be augmented by rigorous compatibility testing. Research into the fundamental relationship between leachables and drug substances will be necessary so the more time- and cost-efficient 'measure and infer' approach can be widely implemented.

  14. High aspect ratio, remote controlled pumping assembly

    Science.gov (United States)

    Brown, Steve B.; Milanovich, Fred P.

    1995-01-01

    A miniature dual syringe-type pump assembly which has a high aspect ratio and which is remotely controlled, for use such as in a small diameter penetrometer cone or well packer used in water contamination applications. The pump assembly may be used to supply and remove a reagent to a water contamination sensor, for example, and includes a motor, gearhead and motor encoder assembly for turning a drive screw for an actuator which provides pushing on one syringe and pulling on the other syringe for injecting new reagent and withdrawing used reagent from an associated sensor.

  15. The association of syringe type and syringe cleaning with HCV infection among IDUs in Budapest, Hungary

    Science.gov (United States)

    Gyarmathy, V. Anna; Neaigus, Alan; Mitchell, Mary M.; Ujhelyi, Eszter

    2008-01-01

    We assessed whether syringe type, syringe cleaning and distributive syringe sharing were associated with self-reported and laboratory confirmed HCV infection among Hungarian IDUs. Injecting drug users (N=215) were recruited from non-treatment settings in Budapest, Hungary between October 2005 and December 2006. Multivariate logistic regression models identified correlates of self-report of being HCV infected and testing positive for HCV. While 37% tested positive for HCV, 14% of the total (39% of those who tested positive) self-reported being HCV infected. Using any two piece syringes was significantly associated with self-reported HCV infection, while distributive syringe sharing was not associated with self-report of being HCV infected. Engaging in receptive sharing of only one-piece syringes but always cleaning before reuse was not associated with testing HCV positive, while any receptive sharing of only one-piece syringes and not always cleaning before reuse was significantly associated with testing HCV positive. Sharing cookers and squirting drugs from one syringe into another syringe were not associated with testing HCV positive. The high percent of those HCV infected who did not know they were infected highlights the need to provide better access to confidential testing and counseling services. Counseling should emphasize secondary prevention of HCV among HCV infected IDUs. Our findings also indicate that syringe type and syringe cleaning practices may play a role in HCV transmission. Ethnographic research should identify the reasons why IDUs may use two-piece syringes and suggest means to reduce their use. Thorough cleaning of one-piece syringes when sterile syringes are unavailable may be an efficient way to reduce the risk of HCV infection. PMID:19058925

  16. Syringe-vacuum microfluidics: A portable technique to create monodisperse emulsions.

    Science.gov (United States)

    Abate, Adam R; Weitz, David A

    2011-03-16

    We present a simple method for creating monodisperse emulsions with microfluidic devices. Unlike conventional approaches that require bulky pumps, control computers, and expertise with device physics to operate devices, our method requires only the microfluidic device and a hand-operated syringe. The fluids needed for the emulsion are loaded into the device inlets, while the syringe is used to create a vacuum at the device outlet; this sucks the fluids through the channels, generating the drops. By controlling the hydrodynamic resistances of the channels using hydrodynamic resistors and valves, we are able to control the properties of the drops. This provides a simple and highly portable method for creating monodisperse emulsions.

  17. Glad you brought it up: a patient-centred programme to reduce proton-pump inhibitor prescribing in general medical practice.

    Science.gov (United States)

    Murie, Jill; Allen, Jane; Simmonds, Ray; de Wet, Carl

    2012-01-01

    Many patients unnecessarily receive proton-pump inhibitor (PPI) drugs long term with significant financial and safety implications. Educating, empowering and supporting patients to self-manage their symptoms can lead to significant and sustained reductions in PPI prescribing. We aimed to implement a programme to reduce inappropriate PPI prescribing. Eligible patients in one general medical practice in rural Scotland were invited for participation between November 2008 and February 2010. Patients attended special nurse advisor clinics, completed dyspepsia questionnaires, received information, formulated self-management plans and were offered flexible support. Of the study population, 437/2883 (15%) were prescribed PPIs. Of these, 166 (38%) were judged eligible for participation. After 12 months, 138/157 (83%) had reduced or stopped their PPIs, while 19/157 (11%) had reverted. The estimated annual net saving in the prescribing budget was ?3180.67. Self-reported understanding of symptom self-management increased from 6/20 (30%) to 18/20 (90%) patients after participation in the programme. A patient-centred programme delivered by a specialist nurse significantly reduced PPI prescribing with financial and potential therapeutic benefits. The vast majority of eligible patients were able to 'step down and off' or 'step off' PPI use after 12 months without any complications or deteriorating symptom control. Further research with larger cohorts of practices and patients is needed to develop a feasible, acceptable and effective programme if similar benefits are to be achieved for primary care in general.

  18. Sharing of Needles and Syringes among Men Who Inject Drugs: HIV Risk in Northwest Bangladesh.

    Directory of Open Access Journals (Sweden)

    M Kamal Pasa

    Full Text Available Injection drug use is prevalent in northwestern Bangladesh. We sought to explore the context of needle/syringe sharing among persons who inject drugs (PWID, examining risk exposures to blood-borne infections like the human immunodeficiency virus (HIV and hepatitis in a region where these dual epidemics are likely to expand.We used a qualitative research approach to learn about injection practices, conducting 60 in-depth interviews among PWID. We then conducted 12 focus group discussions (FGDs that generated a checklist of salient issues, and followed up with personal observations of typical days at the drug-use venues. Content and interpretative frameworks were used to analyze qualitative information and socio-demographic information, using SPSS software.We found that needle/syringe-sharing behaviours were integrated into the overall social and cultural lives of drug users. Sharing behaviours were an central component of PWID social organization. Sharing was perceived as an inherent element within reciprocal relationships, and sharing was tied to beliefs about drug effects, economic adversity, and harassment due to their drug user status. Carrying used needles/syringes to drug-use venues was deemed essential since user-unfriendly needle-syringe distribution schedules of harm reduction programmes made it difficult to access clean needles/syringes in off-hours. PWID had low self-esteem. Unequal power relationships were reported between the field workers of harm reduction programmes and PWID. Field workers expressed anti-PWID bias and judgmental attitudes, and also had had misconceptions about HIV and hepatitis transmission. PWID were especially disturbed that no assistance was forthcoming from risk reduction programme staff when drug users manifested withdrawal symptoms.Interventions must take social context into account when scaling up programmes in diverse settings. The social organization of PWID include values that foster needle-syringe

  19. A water pumping control system with a programmable logic controller (PLC) and industrial wireless modules for industrial plants--an experimental setup.

    Science.gov (United States)

    Bayindir, Ramazan; Cetinceviz, Yucel

    2011-04-01

    This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  20. [The effect of colored syringes and a colored sheet on the incidence of syringe swaps during anesthetic management].

    Science.gov (United States)

    Hirabayashi, Yoshihiro; Kawakami, Takayuki; Suzuki, Hideo; Igarashi, Takashi; Saitoh, Kazuhiko; Seo, Norimasa

    2005-09-01

    Syringe swap is an important problem in anesthetic care, causing harm to patients. We examined the effect of colored syringe and a colored sheet on the incidence of syringe swaps during anesthetic management. We determined the color code. The blue-syringe contains local anesthetics; yellow-syringe, sympathomimetic drugs; and white-syringe with a red label fixed opposite the scale, muscle relaxants. The colored sheet displays the photographs of the syringe with drug name, dose and volume. The colored syringe and colored sheet were supplied for use from February 2004. We compared the incidence of syringe swaps during the period from February 2004 to January 2005 with that from February 2003 to January 2004. Although five syringe swaps were recorded from February 2003 to January 2004, in 5901 procedures, we encountered no syringe swaps from February 2004 to January 2005, in 6078 procedures. The colored syringe and colored sheet significantly decreased the incidence of syringe swaps during anesthetic management (P sheet together with colored syringes can prevent syringe swaps during anesthesia.

  1. Thermo-pumps: their operating principles, the Vivrelec program; Les thermopompes: principes de fonctionnement, le programme Vivrelec

    Energy Technology Data Exchange (ETDEWEB)

    Horber, B. [Electricite de France (EDF), 75 - Paris (France)

    1997-12-31

    The Vivrelec EDF (Electricite de France) program is aimed at ensuring thermal comfort for residential homes, based on thermal performance (building insulation, ventilation), a range of electric heating equipment, programming and energy management systems, and services. In the framework of Vivrelec, reverse cycle refrigerating circuits are also proposed; its main principles are reviewed, based on two refrigerant/air heat exchangers, a compressor, a pressure reducing valve and a four-way valve. Energy and acoustic performances have been notably enhanced through the use of rotary compressors, brazed plate exchangers and advanced tubular exchangers, electronic regulation, etc. Three types of equipment are available: air conditioners, reverse air/water heat pumps (low or medium temperature) and ground-glycol water/water heat pumps (low and medium temperature)

  2. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    Science.gov (United States)

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  3. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  4. In-syringe-stirring: A novel approach for magnetic stirring-assisted dispersive liquid–liquid microextraction

    International Nuclear Information System (INIS)

    Horstkotte, Burkhard; Suárez, Ruth; Solich, Petr; Cerdà, Víctor

    2013-01-01

    Graphical abstract: -- Highlights: •We propose a new automatic magnetic stirring assisted dispersive liquid–liquid microextraction. •It allows the extraction of aluminum from seawater and freshwater samples within less than 4 min. •The method was applicable to the natural samples. -- Abstract: For the first time, the use of a magnetic stirrer within the syringe of an automated syringe pump and the resulting possible analytical applications are described. A simple instrumentation following roughly the one from sequential injection analyzer systems is used in combination with an adaptor, which is placed onto the barrel of a glass syringe. Swirling around the longitudinal axis of the syringe and holding two strong neodymium magnets, it causes a rotating magnetic field and serves as driver for a magnetic stirring bar placed inside of the syringe. In a first study it was shown that this approach leads to a sealed but also automatically adaptable reaction vessel, the syringe, in which rapid and homogeneous mixing of sample with the required reagents within short time can be carried out. In a second study in-a-syringe magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) was demonstrated by the application of the analyzer system to fluorimetric determination of aluminum in seawater samples using lumogallion. A linear working range up to 1.1 μmol L −1 and a limit of detection of 6.1 nmol L −1 were found. An average recovery of 106.0% was achieved for coastal seawaters with a reproducibility of 4.4%. The procedure lasted 210 s including syringe cleaning and only 150 μL of hexanol and 4.1 mL of sample were required

  5. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  6. Aspects of syringeal mechanics in avian phonation

    NARCIS (Netherlands)

    Larsen, O.N.; Goller, F.; Leeuwen, van J.L.

    2006-01-01

    The vocal organ of birds, the syrinx, is formed by modified cartilages of the trachea and bronchi. Recently, the use of thin, flexible endoscopes has made direct observation of the syrinx possible in situ. The effects of direct muscle stimulation on the syringeal aperture identified adductor and

  7. Syringe irrigation: blending endodontics and fluid dynamics

    NARCIS (Netherlands)

    Boutsioukis, C.; van der Sluis, L.W.M.; Basrani, B.

    2015-01-01

    Syringe irrigation remains a widely used irrigant delivery method during root canal treatment. An interdisciplinary approach involving well-established methods from the field of fluid dynamics can provide new insights into the mechanisms involved in cleaning and disinfection of the root canal system

  8. Development of Syringe/Bottle Hybrids for Sampling Slurries

    International Nuclear Information System (INIS)

    Coleman, C.J.

    1998-01-01

    A convenient and effective sample bottle system based on simple modifications of disposable plastic syringes and bottles has been devised and tested for slurry samples. Syringe/ bottle hybrids (hereafter referred to as syringe bottles) have the convenience of regular flat-bottom bottles with screw cap closures. In addition, the syringe imparts a sliding and adjustable bottom to the bottle that forces the entire contents from the bottle. The system was designed especially to collect samples for high temperature work-ups of DWPF slurry samples. The syringe bottles together with fixed-bottom sample vial inserts would provide the DWPF with convenient and reliable methods for dealing with slurry samples

  9. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study

    OpenAIRE

    Hiremath, Mallayya C.; Srivastava, Pooja

    2016-01-01

    Purpose: The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. Materials and Methods: A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presenc...

  10. From medicine to natural philosophy: Francis Hauksbee's way to the air-pump.

    Science.gov (United States)

    Brundtland, Terje

    2008-06-01

    Francis Hauksbee (1660-1713) is well known for his double-barrelled air-pump. However, the origin of this pump, and Hauksbee's background, are often described as a mystery. This text seeks to dispel the riddle. It is argued that Hauksbee's competence as an exceptional maker of air-pumps was developed between 1699 and 1703 as a result of his experiences with the construction, manufacturing and sale of cupping-glasses. His cupping utensils embodied a new design, where syringes were used to evacuate the glasses, instead of the traditional way by fire or mouth suction. These syringes, which in fact were small air-pumps, were perfected between 1699 and 1701. A larger syringe, introduced in 1701, served as a transition from the cupping-syringe to his first air-pump for use in natural philosophy. This syringe was described as a 'combined engine', which could serve as an air-pump, a condensing engine and a syringe for injecting air, wax or mercury into pathological specimens. Hauksbee's first air-pump was a single-barrelled model introduced in 1702, based on the combined engine. Its various features, such as easy and convenient leak-tightening, exact pressure measurements by an in-built barometer and an air-inlet function for readmission of air into the receiver, are discussed. Finally, it is shown that these activities gave Hauksbee the reputation of being an outstanding instrument-maker, years before the double-barrelled air-pump was in sight.

  11. Community syringe collection and disposal policies in 16 states.

    Science.gov (United States)

    Turnberg, Wayne L; Jones, T Stephen

    2002-01-01

    To review laws, regulations, and guidelines that affect the collection and disposal of hypodermic needles, syringes, and lancets used outside of professional health care settings (hereafter referred to as "community syringes"). Law and policy analysis. Alabama, California, Florida, Georgia, Hawaii, Massachusetts, Michigan, Minnesota, New Jersey, New York, Ohio, Oregon, Rhode Island, South Carolina, Washington, and Wisconsin. Information on syringe collection and disposal in the community was gathered from federal and state records and state agency personnel. Legally permissible means of syringe collection and disposal available to persons in the community injecting medical treatments and injection drug users. Laws, regulations, or guidelines in 13 states allowed community syringes to be legally discarded in household trash; guidelines for in-trash disposal varied among the states. Only 6 states had laws or regulations that specifically addressed community syringe collection. In 10 states, infectious waste laws and regulations that apply to medical facilities such as clinics would also apply to community syringe collection sites. In the 16 states studied, laws, regulations, and guidelines relating to community syringe collection and disposal were somewhat inconsistent and confusing and presented potential barriers to safe disposal. States should consider amending laws, regulations, and guidelines to promote community syringe collection programs. A national effort is needed to achieve consistent community syringe collection and disposal laws and guidelines for all states. Pharmacists can aid in safe syringe disposal by counseling their patients about safe disposal, providing or selling sharps containers, and accepting used syringes for safe disposal. Pharmacists can join other interested groups in advocating clarification of disposal laws and regulations that favor community programs designed to keep syringes out of the trash so that they can be disposed of as

  12. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    Science.gov (United States)

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  13. Different elution modes and field programming in gravitational field-flow fractionation. III. Field programming by flow-rate gradient generated by a programmable pump.

    Science.gov (United States)

    Plocková, J; Chmelík, J

    2001-05-25

    Gravitational field-flow fractionation (GFFF) utilizes the Earth's gravitational field as an external force that causes the settlement of particles towards the channel accumulation wall. Hydrodynamic lift forces oppose this action by elevating particles away from the channel accumulation wall. These two counteracting forces enable modulation of the resulting force field acting on particles in GFFF. In this work, force-field programming based on modulating the magnitude of hydrodynamic lift forces was implemented via changes of flow-rate, which was accomplished by a programmable pump. Several flow-rate gradients (step gradients, linear gradients, parabolic, and combined gradients) were tested and evaluated as tools for optimization of the separation of a silica gel particle mixture. The influence of increasing amount of sample injected on the peak resolution under flow-rate gradient conditions was also investigated. This is the first time that flow-rate gradients have been implemented for programming of the resulting force field acting on particles in GFFF.

  14. A study of gross morphological and histological syringeal features of ...

    African Journals Online (AJOL)

    A study of gross morphological and histological syringeal features of true francolins (Galliformes: Francolinus, Scleroptila, Peliperdix and Dendroperdix spp.) and spurfowls ( Pternistis spp.) in a phylogenetic context.

  15. Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Peláez, Sarah S; Mahler, Hanns-Christian; Matter, Anja; Koulov, Atanas; Singh, Satish K; Germershaus, Oliver; Mathaes, Roman

    2018-04-04

    Prefilled syringes (PFSs) are increasingly preferred over vials as container closure systems (CCSs) for injectable drug products when facilitated or self-administration is required. However, PFSs are more complex compared to CCSs consisting of vial, rubber stopper and crimp cap. Container closure integrity (CCI) assurance and verification has been a specific challenge for PFSs as they feature several sealing areas. A comprehensive understanding of the CCS is necessary for an appropriate CCI assessment as well as for packaging development and qualification. A comprehensive CCI assessment of six different PFSs from three different manufacturers (including one polymeric PFS) was conducted using helium leak testing. PFS components were manipulated to systematically assess the contribution of the different sealing areas to CCI, namely rigid needle shield (RNS)/needle, RNS/tip cone and the individual ribs of a syringe plunger. The polymeric PFS required an equilibrium measurement for accurate CCIT. The different sealing areas and a single plunger rib were shown to provide adequate CCI. Acceptable tip cap movement until the point of CCI failure was estimated. The assessment of acceptable tip cap movement demonstrated the importance of considering the RNS/tip cone seal design to ensure CCI of the PFS upon post assembly possesses and shipment. Copyright © 2018. Published by Elsevier Inc.

  16. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    Directory of Open Access Journals (Sweden)

    Alexander RW

    2013-04-01

    Full Text Available Robert W Alexander,1 David Harrell2 1Department of Surgery, School of Medicine and Dentistry, University of Washington, Seattle, WA, USA; 2Harvest-Terumo Inc, Plymouth, MA, USA Objectives: Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG with use of disposable, microcannula systems. Design: Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. Results: Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. Conclusion: Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are

  17. 21 CFR 870.1670 - Syringe actuator for an injector.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Syringe actuator for an injector. 870.1670 Section 870.1670 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... actuator for an injector. (a) Identification. A syringe actuator for an injector is an electrical device...

  18. Social-structural contexts of needle and syringe sharing behaviours of HIV-positive injecting drug users in Manipur, India: a mixed methods investigation

    Directory of Open Access Journals (Sweden)

    Shunmugam Murali

    2011-05-01

    Full Text Available Abstract Background Few investigations have assessed risk behaviours and social-structural contexts of risk among injecting drug users (IDUs in Northeast India, where injecting drug use is the major route of HIV transmission. Investigations of risk environments are needed to inform development of effective risk reduction interventions. Methods This mixed methods study of HIV-positive IDUs in Manipur included a structured survey (n = 75, two focus groups (n = 17, seven in-depth interviews, and two key informant interviews. Results One-third of survey participants reported having shared a needle/syringe in the past 30 days; among these, all the men and about one-third of the women did so with persons of unknown HIV serostatus. A variety of social-structural contextual factors influenced individual risk behaviours: barriers to carrying sterile needles/syringes due to fear of harassment by police and "anti-drug" organizations; lack of sterile needles/syringes in drug dealers' locales; limited access to pharmacy-sold needles/syringes; inadequate coverage by needle and syringe programmes (NSPs; non-availability of sterile needles/syringes in prisons; and withdrawal symptoms superseding concern for health. Some HIV-positive IDUs who shared needles/syringes reported adopting risk reduction strategies: being the 'last receiver' of needles/syringes and not a 'giver;' sharing only with other IDUs they knew to be HIV-positive; and, when a 'giver,' asking other IDUs to wash used needles/syringes with bleach before using. Conclusions Effective HIV prevention and care programmes for IDUs in Northeast India may hinge on several enabling contexts: supportive government policy on harm reduction programmes, including in prisons; an end to harassment by the police, army, and anti-drug groups, with education of these entities regarding harm reduction, creation of partnerships with the public health sector, and accountability to government policies that protect IDUs

  19. Predicting pharmacy syringe sales to people who inject drugs: Policy, practice and perceptions.

    Science.gov (United States)

    Meyerson, Beth E; Davis, Alissa; Agley, Jon D; Shannon, David J; Lawrence, Carrie A; Ryder, Priscilla T; Ritchie, Karleen; Gassman, Ruth

    2018-06-01

    Pharmacies have much to contribute to the health of people who inject drugs (PWID) and to community efforts in HIV and hepatitis C (HCV) prevention through syringe access. However, little is known about what predicts pharmacy syringe sales without a prescription. To identify factors predicting pharmacy syringes sales to PWID. A hybrid staggered online survey of 298 Indiana community pharmacists occurred from July-September 2016 measuring pharmacy policy, practice, and pharmacist perceptions about syringe sales to PWID. Separate bivariate logistical regressions were followed by multivariable logistic regression to predict pharmacy syringe sales and pharmacist comfort dispensing syringes to PWID. Half (50.5%) of Indiana pharmacies sold syringes without a prescription to PWID. Pharmacy syringe sales was strongly associated with pharmacist supportive beliefs about syringe access by PWID and their comfort level selling syringes to PWID. Notably, pharmacies located in communities with high rates of opioid overdose mortality were 56% less likely to sell syringes without a prescription than those in communities with lower rates. Pharmacist comfort dispensing syringes was associated with being male, working at a pharmacy that sold syringes to PWID and one that stocked naloxone, having been asked about syringe access by medical providers, and agreement that PWID should be able to buy syringes without a prescription. As communities with high rates of opioid overdose mortality were less likely to have pharmacies that dispensed syringes to PWID, a concerted effort with these communities and their pharmacies should be made to understand opportunities to increase syringe access. Future studies should explore nuances between theoretical support for syringe access by PWID without a prescription and actual dispensing behaviors. Addressing potential policy conflicts and offering continuing education on non-prescription syringe distribution for pharmacists may improve comfort

  20. Attitudes of North Carolina law enforcement officers toward syringe decriminalization

    Science.gov (United States)

    Davis, Corey S.; Johnston, Jill; Zerden, Lisa de Saxe; Clark, Katie; Castillo, Tessie; Childs, Robert

    2015-01-01

    Background North Carolina, like much of the U.S. South, is disproportionately affected by HIV and hepatitis. This persistently high disease burden may be driven in part by laws that criminalize the possession and distribution of syringes for illicit drug use. Legal change to decriminalize syringes may reduce infection rates in the state, but is unlikely absent support from law enforcement actors. Methods We analyzed the responses of 350 North Carolina law enforcement officers to a confidential, anonymous survey. The survey instrument collected data regarding self-reported needle-stick injury (NSI), blood borne disease risk perception and attitudes toward syringe decriminalization. Results 82% of respondents reported that contracting HIV was a “big concern” for them. 3.8% of respondents reported ever receiving a job-related NSI, a rate of 36 NSI per 10,000 officer-years. Majorities of respondents reported positive views regarding syringe decriminalization, with approximately 63% agreeing that it would be “good for the community” and 60% agreeing that it would be “good for law enforcement.” Black and female officers were significantly less likely to agree that on-the-job NSI was a “big concern” and significantly more likely to agree that it would be good for law enforcement. Conclusions These findings suggest that many North Carolina LEOs understand the public health benefits of syringe access programs and may be inclined to support syringe decriminalization legislation. Further research is indicated to determine the causes of observed differences in perceptions of bloodborne disease risk and attitudes toward syringe decriminalization by race and sex. PMID:25193720

  1. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  2. Not sold here: limited access to legally available syringes at pharmacies in Tijuana, Mexico.

    Science.gov (United States)

    Pollini, Robin A; Rosen, Perth C; Gallardo, Manuel; Robles, Brenda; Brouwer, Kimberly C; Macalino, Grace E; Lozada, Remedios

    2011-05-24

    Sterile syringe access is a critical component of HIV prevention programs. Although retail pharmacies provide convenient outlets for syringe access, injection drug users (IDUs) may encounter barriers to syringe purchase even where purchase without a prescription is legal. We sought to obtain an objective measure of syringe access in Tijuana, Mexico, where IDUs report being denied or overcharged for syringes at pharmacies. Trained "mystery shoppers" attempted to buy a 1 cc insulin syringe according to a predetermined script at all retail pharmacies in three Tijuana neighborhoods. The same pharmacies were surveyed by telephone regarding their syringe sales policies. Data on purchase attempts were analyzed using basic statistics to obtain an objective measure of syringe access and compared with data on stated sales policies to ascertain consistency. Only 46 (28.4%) of 162 syringe purchase attempts were successful. Leading reasons for unsuccessful attempts were being told that the pharmacy didn't sell syringes (35.3%), there were no syringes in stock (31.0%), or a prescription was required (20.7%). Of 136 pharmacies also surveyed by telephone, a majority (88.2%) reported selling syringes but only one-third (32.5%) had a successful mystery shopper purchase; the majority of unsuccessful purchases were attributed to being told the pharmacy didn't sell syringes. There was similar discordance regarding prescription policies: 74 pharmacies said in the telephone survey that they did not require a prescription for syringes, yet 10 of these pharmacies asked the mystery shopper for a prescription. IDUs in Tijuana have limited access to syringes through retail pharmacies and policies and practices regarding syringe sales are inconsistent. Reasons for these restrictive and inconsistent practices must be identified and addressed to expand syringe access, reduce syringe sharing and prevent HIV transmission.

  3. Retention and variability of hydrogen (H2) samples stored in plastic syringes

    DEFF Research Database (Denmark)

    Rumessen, J J; Gudmand-Høyer, E

    1987-01-01

    The utility of two brands of 20 ml plastic syringes for storage of hydrogen (H2) samples as obtained in H2 breath tests were studied. Plastipak syringes were found to be significantly better with regard to the stability of the H2 concentration and the variability between the H2 samples. Storage...... of the H2 samples in Plastipak syringes at 5 degrees C significantly improved the H2 retention, whereas refrigeration of H2 samples stored in Once syringes did not reduce H2 loss. Storage of H2 samples in refrigerated plastic syringes is efficient and reliable for several days if syringes with minimal...... sample variation are used....

  4. Spring-loaded syringe for multiple rapid injections

    Directory of Open Access Journals (Sweden)

    C R Srinivas

    2017-01-01

    Full Text Available Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage.

  5. Spring-loaded Syringe for Multiple Rapid Injections

    Science.gov (United States)

    Srinivas, CR; Somani, Anirudh; Shashidharan Nair, CK; Mylswamy, Thirumurthy

    2017-01-01

    Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage. PMID:28529423

  6. Options for reducing HIV transmission related to the dead space in needles and syringes.

    Science.gov (United States)

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  7. Gas fired heat pumps

    International Nuclear Information System (INIS)

    Seifert, M.

    2006-01-01

    The condensing gas boiler is now state of the art and there is no more room for improvement in performance, technically speaking. The next logical step to improve the overall efficiency is to exploit ambient heat in combination with the primary source of energy, natural gas. That means using natural-gas driven heat pumps and gas-fired heat pumps. Based on this, the Swiss Gas Industry decided to set up a practical test programme enjoying a high priority. The aim of the project 'Gas-fired heat pump practical test' is to assess by field tests the characteristics and performance of the foreign serial heat pumps currently on the market and to prepare and promote the introduction on the market place of this sustainable natural-gas technology. (author)

  8. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  9. Electromagnetic pump technology

    International Nuclear Information System (INIS)

    Prabhakar, R.

    1994-01-01

    Fast Breeder Reactors have an important role to play in our nuclear power programme. Liquid metal sodium is used as the coolant for removing fission heat generated in fast reactors and a distinctive physical property of sodium is its high electrical conductivity. This enables application of electromagnetic (EM) pumps, working on same principle as electric motors, for pumping liquid sodium. Due to its lower efficiency as compared to centrifugal pumps, use of EM pumps has been restricted to reactor auxiliary circuits and experimental facilities. As part of our efforts to manufacture fast reactor components indigenously, work on the development of two types of EM pumps namely flat linear induction pump (FLIP) and annular linear induction pump (ALIP) has been undertaken. Design procedures based on an equivalent circuit approach have been established and results from testing a 5.6 x 10E-3 Cum/s (20 Cum/h) FLIP in a sodium loop were used to validate the procedure. (author). 7 refs., 6 figs

  10. Determining serum bicarbonate; a simple syringe titrator and colorimeter.

    Science.gov (United States)

    BOONE, C W; FIELD, J B

    1953-12-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity.

  11. Physical stability of 20% lipid injectable emulsions via simulated syringe infusion: effects of glass vs plastic product packaging.

    Science.gov (United States)

    Driscoll, David F; Ling, Pei-Ra; Bistrian, Bruce R

    2007-01-01

    The United States Pharmacopeia (USP) has proposed large-globule-size limits to ensure the physical stability of lipid injectable emulsions, expressed as the percent fat >5 microm, or PFAT(5), not exceeding 0.05%. Visibly obvious phase separation as free oil has been shown to occur in some samples if PFAT(5) is >0.4%. We recently found that lipids, newly packaged in plastic (P), exceed the proposed USP limits and seem to produce less stable total nutrient admixtures compared with those made from conventional glass (G), which do meet proposed USP standards. We tested the possible stability differences between 20% lipid injectable emulsions in either P or G in a simulated neonatal syringe infusion study. Eighteen individual syringes were prepared from each 20% lipid injectable emulsion product (n = 36) and attached to a syringe pump set at an infusion rate of 0.5 mL/hour. The starting PFAT(5) levels were measured at time 0 and after 24 hours of infusion, using a laser-based light obscuration technique as described by the USP Chapter . The data were assessed by a 2-way analysis of variance (ANOVA) with Container (G vs P) and Time as the independent variables and PFAT as the dependent variable. At time 0, the starting PFAT(5) level for lipids packaged in G was 0.006% +/- 0.001% vs 0.162% +/- 0.026% for P, whereas at the end of the infusion they were 0.013% +/- 0.003% and 0.328% +/- 0.046%, respectively. Significant differences were noted overall between groups for Container, Time, and Container-Time interaction (all p emulsions packaged in newly introduced plastic containers exceed the proposed USP PFAT(5) limits and subsequently become significantly less stable during a simulated syringe-based infusion. Although modest growth (p = NS) in large-diameter fat globules was observed for the glass-based lipids, they remained within proposed USP globule size limits throughout the study. Glass-based lipids seem to be a more stable dosage form and potentially a safer way to

  12. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  13. Reuse prevention syringes for reconstitution of lyophilized vaccines: Operational study and UNICEF plans for expanding introduction.

    Science.gov (United States)

    Fleming, Jessica A; Hoekstra, Edward John; Moniaga, Vanda; Widjaya, Anton; Soepardi, Jane; Supartha, Nyoman; Salovaara, Annika; Khamassi, Selma; Nelson, Carib

    2009-01-01

    Since the 1990s, the United Nation's Children's Fund has encouraged injection safety for immunizations through bundling vaccines with appropriate amounts of supporting equipment and by supplying autodisable (AD) syringes for injections. However, poor vaccine reconstitution practices continue to be reported worldwide. By 2009, UNICEF will begin to phase out the distribution of standard disposable syringes for vaccine reconstitution and replace them with reuse prevention (RUP) syringes, with a full transition expected by the end of 2010. A field evaluation in Indonesia was conducted to identify introduction requirements, issues with healthcare worker training and acceptance, and RUP syringe performance and safety. Managers and health workers felt that RUP syringes improved injection safety and fit easily into country logistical systems. Healthcare workers felt they were intuitive to use, but recommended special training. The integration of RUP reconstitution syringes by UNICEF could increase injection safety by preventing the reuse of syringes and reducing vaccine contamination.

  14. Prefilled syringes for intravitreal injection reduce preparation time

    DEFF Research Database (Denmark)

    Subhi, Yousif; Kjer, Birgit; Munch, Inger Christine

    2016-01-01

    INTRODUCTION: The demand for intravitreal therapy has increased dramatically with the introduction of vascular endo-thelial growth factor inhibitors. Improved utilisation of existing resources is crucial to meeting the increased future demand. We investigated time spent preparing intravitreal inj...... had no influence on the design of the study, analysis of the data, preparation of the manuscript or the decision to publish. TRIAL REGISTRATION: not relevant.......INTRODUCTION: The demand for intravitreal therapy has increased dramatically with the introduction of vascular endo-thelial growth factor inhibitors. Improved utilisation of existing resources is crucial to meeting the increased future demand. We investigated time spent preparing intravitreal...... injection treatment using either prefilled syringes or vials in routine clinical practice. METHODS: We video-recorded preparations of intravitreal injections (n = 172) for each preparation type (ranibizumab prefilled syringe (n = 56), ranibizumab vial (n = 56) and aflibercept vial (n = 60)) in a multi...

  15. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  16. DETERMINING SERUM BICARBONATE—A Simple Syringe Titrator and Colorimeter

    Science.gov (United States)

    Boone, Charles W.; Field, John B.

    1953-01-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity. PMID:13106724

  17. Stability of erythropoietin repackaging in polypropylene syringes for clinical use

    Directory of Open Access Journals (Sweden)

    Angela Marsili

    2017-02-01

    Full Text Available Introduction: Epoetin alfa (Eprex® is a subcutaneous, injectable formulation of short half-life recombinant human erythropoietin (rHuEPO. To current knowledge there are no published studies regarding the stability of rHuEPO once repackaging occurs (r-EPO for clinical trial purposes. Materials and methods: We assessed EPO concentration in Eprex® and r-EPO syringes at 0, 60, 90, and 120 days after repackaging in polypropylene syringes. R-EPO was administered to 56 patients taking part in a clinical trial in Friedreich Ataxia. Serum EPO levels were measured at baseline and 48 h after r-EPO administration. Results: No differences were found between r-EPO and Eprex® syringes, but both globally decreased in total EPO content during storage at 4 °C. Patients receiving r-EPO had similar levels in EPO content as expected from previous trials in Friedreich Ataxia and from pharmacokinetics studies in healthy volunteers. Discussion: We demonstrate that repackaging of EPO does not alter its concentration if compared to the original product (Eprex®. This is true both for repackaging procedures and for the stability in polypropylene tubes. The expiration date of r-EPO can be extended from 1 to 4 months after repackaging, in accordance with pharmacopeia rules.

  18. Adrenaline in cardiac arrest: Prefilled syringes are faster.

    Science.gov (United States)

    Helm, Claire; Gillett, Mark

    2015-08-01

    Standard ampoules and prefilled syringes of adrenaline are widely available in Australasian EDs for use in cardiac arrest. We hypothesise that prefilled syringes can be administered more rapidly and accurately when compared with the two available standard ampoules. This is a triple arm superiority study comparing the time to i.v. administration and accuracy of dosing of three currently available preparations of adrenaline. In their standard packaging, prefilled syringes were on average more than 12 s faster to administer than the 1 mL 1:1000 ampoules and more than 16 s faster than the 10 mL 1:10,000 ampoules (P adrenaline utilising a Minijet (CSL Limited, Parkville, Victoria, Australia) is faster than using adrenaline in glass ampoules presented in their plastic packaging. Removing the plastic packaging from the 1 mL (1 mg) ampoule might result in more rapid administration similar to the Minijet. Resuscitation personnel requiring rapid access to adrenaline should consider storing it as either Minijets or ampoules devoid of packaging. These results might be extrapolatable to other clinical scenarios, including pre-hospital and anaesthesia, where other drugs are required for rapid use. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  19. Lab-In-Syringe automation of stirring-assisted room-temperature headspace extraction coupled online to gas chromatography with flame ionization detection for determination of benzene, toluene, ethylbenzene, and xylenes in surface waters.

    Science.gov (United States)

    Horstkotte, Burkhard; Lopez de Los Mozos Atochero, Natalia; Solich, Petr

    2018-06-22

    Online coupling of Lab-In-Syringe automated headspace extraction to gas chromatography has been studied. The developed methodology was successfully applied to surface water analysis using benzene, toluene, ethylbenzene, and xylenes as model analytes. The extraction system consisted of an automatic syringe pump with a 5 mL syringe into which all solutions and air for headspace formation were aspirated. The syringe piston featured a longitudinal channel, which allowed connecting the syringe void directly to a gas chromatograph with flame ionization detector via a transfer capillary. Gas injection was achieved via opening a computer-controlled pinch valve and compressing the headspace, upon which separation was initialized. Extractions were performed at room temperature; yet sensitivity comparable to previous work was obtained by high headspace to sample ratio V HS /V Sample of 1.6:1 and injection of about 77% of the headspace. Assistance by in-syringe magnetic stirring yielded an about threefold increase in extraction efficiency. Interferences were compensated by using chlorobenzene as an internal standard. Syringe cleaning and extraction lasting over 10 min was carried out in parallel to the chromatographic run enabling a time of analysis of <19 min. Excellent peak area repeatabilities with RSD of <4% when omitting and <2% RSD when using internal standard corrections on 100 μg L -1 level were achieved. An average recovery of 97.7% and limit of detection of 1-2 μg L -1 were obtained in analyses of surface water. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Over-the-counter but out of reach: a pharmacy-based survey of OTC syringe sales in Tijuana, Mexico.

    Science.gov (United States)

    Pollini, Robin A; Gallardo, Manuel; Ruiz, Serena; Case, Patricia; Zaller, Nickolas; Lozada, Remedios

    2014-05-01

    Sterile syringe access is critical to HIV prevention efforts targeting injection drug users (IDUs) but some pharmacies do not sell syringes over-the-counter (OTC) even where such sales are legal. We conducted a pharmacy survey in Tijuana, Mexico (where OTC sales are legal) to characterize attitudes toward syringe sales and to explore support for expanding pharmacy-based HIV prevention efforts. Of 203 respondents, 28% supported OTC syringe sales to IDUs and 74% said their pharmacy required a prescription for at least some syringe sales. Support for OTC syringe sales was independently associated with selling OTC syringes, understanding the role of sterile syringes in HIV prevention, and recognizing pharmacies as an important health resource for IDUs. Most respondents supported an expanded role for pharmacies in HIV prevention, exclusive of OTC syringe sales. Our study provides information for developing interventions to promote OTC syringe sales and expanding pharmacy-based distribution of HIV-related information and resources.

  1. Survival of Hepatitis C Virus in Syringes: Implication for Transmission among Injection Drug Users

    Science.gov (United States)

    Paintsil, Elijah; He, Huijie; Peters, Christopher; Lindenbach, Brett D.; Heimer, Robert

    2010-01-01

    Background We hypothesized that the high prevalence of HCV among injection drug users (IDUs) might be due to prolonged virus survival in contaminated syringes. Methods We developed a microculture assay to examine the viability of HCV. Syringes were loaded with blood spiked with HCV reporter virus (Jc1/GLuc2A) to simulate two scenarios of residual volumes; low (2 μl) void volume for 1-ml insulin syringes, and high (32 μl) void volume for 1-ml tuberculin syringes. Syringes were stored at 4°C, 22°C, and 37°C for up to 63 days before testing for HCV infectivity using luciferase activity. Results The virus decay rate was biphasic (t½ α = 0.4h and t½β = 28h). Insulin syringes failed to yield viable HCV beyond day one at all storage temperatures except for 4o in which 5% of syringes yielded viable virus on day 7. Tuberculin syringes yielded viable virus from 96%, 71%, and 52% of syringes following storage at 4o, 22° and 37o for 7 days, respectively, and yielded viable virus up to day 63. Conclusions The high prevalence of HCV among IDUs may be partly due to the resilience of the virus and the syringe type. Our findings may be used to guide prevention strategies. PMID:20726768

  2. Pump cavitation and inducer design

    International Nuclear Information System (INIS)

    Heslenfeld, M.W.; Hes, M. de

    2002-01-01

    Details of past work on sodium pump development and cavitation studies executed mainly for SNR 300 were reported earlier. Among the requirements for large sodium pumps are long life (200000 hours up to 300000 hours) and small size of impeller and pump, fully meeting the process and design criteria. These criteria are the required 'Q, H, r characteristics' in combination with a low NPSH value and the avoidance of cavitation damage to the pump. The pump designer has to develop a sound hydraulic combination consisting of suction arrangement, impeller design and diffuser. On the other hand the designer is free to choose an optimal pump speed. The pump speed in its turn influences the rotor dynamic pump design and the pump drive. The introduction of the inducer as an integral part of the pump design is based on following advantages: no tip cavitation; (possible) cavitation bubbles move to the open centre due to centrifugal forces on the fluid; the head of the inducer improves the inlet conditions of the impeller. The aim of an inducer is the increase in the suction specific speed (SA value) of a pump whereby the inducer functions as a pressure source improving the impeller inlet conditions. With inducer-impeller combinations values up to SA=15000 are realistic. With the use of an inducer the overall pump sizes can be reduced with Ca. 30%. Pumps commonly available have SA values up to a maximum of ca. 10000. A development programme was executed for SNR 300 in order to reach an increase of the suction specific speed of the impeller from SA 8200 to SA 11000. Further studies to optimize pumps design for the follow up line introduced the 'inducer acting as a pre-impeller' development. This programme was executed in the period 1979-1981. At the FDO premises a scale 1 2.8 inducer impeller combination with a suction specific speed SA=15000 was developed, constructed and tested at the water test rig. This water test rig is equipped with a perspex pipe allowing also visualisation

  3. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  4. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  5. Syringe access for the prevention of blood borne infections among injection drug users

    Directory of Open Access Journals (Sweden)

    Rich Josiah D

    2003-11-01

    Full Text Available Abstract Background Approximately one-third of acquired immunodeficiency syndrome cases in the United States are associated with the practice of sharing of injection equipment and are preventable through the once-only use of syringes, needles and other injection equipment. Discussion Sterile syringes may be obtained legally by 4 methods depending on the state. They may be purchased over the counter, prescribed, obtained at syringe exchange programs or furnished by authorized agencies. Each of these avenues has advantages and disadvantages; therefore, legal access through all means is the most likely way to promote the use of sterile syringes. Summary By assisting illicit drug injectors to obtain sterile syringes the primary care provider is able to reduce the incidence of blood borne infections, and educate patients about safe syringe disposal. The provider is also able to initiate discussion about drug use in a nonjudgmental manner and to offer care to patients who are not yet ready to consider drug treatment.

  6. Racial differences in acquisition of syringes from pharmacies under conditions of legal but restricted sales.

    Science.gov (United States)

    Costenbader, Elizabeth C; Zule, William A; Coomes, Curtis C

    2010-09-01

    Injecting drug users (IDUs) are at increased risk of acquiring and transmitting HIV and other bloodborne pathogens through the multi-person use of syringes. Although research has shown that increased access to syringes through syringe exchange programs (SEPs) is an effective strategy to reduce risky injection practices many areas of the United States still do not have SEPs. In the absence of SEPs, legislation allowing pharmacies over-the-counter sales of syringes has also been shown to reduce syringe sharing. The success of pharmacy sales however is limited by other legal stipulations, such as drug paraphernalia laws, which in turn may contribute to fear among IDUs about being caught purchasing and carrying syringes. Between 2003 and 2006, 851 out-of-treatment IDUs were recruited using street outreach in the Raleigh-Durham (North Carolina) area. Data were collected using audio-computer assisted interview (ACASI) technology. Multiple logistic regression analyses were performed to assess factors associated with purchasing syringes from pharmacies. In our study sample, African-American IDUs were one-fifth as likely as white IDUs to report pharmacies as their primary source of syringes. Given the absence of syringe exchange programs and the relatively high prevalence of HCV and HIV among IDUs in the Raleigh-Durham area, the limited use of pharmacies as a source of syringes among African-American IDUs in this study sample is problematic. The study findings support the need for effective multilevel interventions to increase access to clean needles in this population, as well as for policy interventions, such as legalization of SEPs and elimination of penalties for carrying syringes, to reduce harm and eliminate the health threats posed by receptive syringe sharing. Copyright 2010 Elsevier B.V. All rights reserved.

  7. Embedded nanomicro syringe on chip for molecular therapy

    Directory of Open Access Journals (Sweden)

    Jalil MA

    2011-11-01

    Full Text Available Muhammad Arif Jalil1, Nathaporn Suwanpayak2,3, Kathawut Kulsirirat3, Saisudawan Suttirak3, Jalil Ali4, Preecha P Yupapin31Ibnu Sina Institute of Fundamental Science Studies, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, Malaysia; 2King Mongkut's Institute of Technology Ladkrabang, Chumphon Campus, Chumphon, Thailand; 3Nanoscale Science and Engineering Research Alliance, Advanced Research Center for Photonics, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand; 4Institute of Advanced Photonics Science, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, MalaysiaBackground: A novel nanomicro syringe system was proposed for drug storage and delivery using a PANDA ring resonator and atomic buffer. A PANDA ring is a modified optical add/drop filter, named after the well known Chinese bear. In principle, the molecule/drug is trapped by the force generated by different combinations of gradient fields and scattering photons within the PANDA ring. A nanomicro needle system can be formed by optical vortices in the liquid core waveguide which can be embedded on a chip, and can be used for long-term treatment. By using intense optical vortices, the required genes/molecules can be trapped and transported dynamically to the intended destinations via the nanomicro syringe, which is available for drug delivery to target tissues, in particular tumors. The advantage of the proposed system is that by confining the treatment area, the effect can be decreased. The use of different optical vortices for therapeutic efficiency is also discussed.Keywords: nanomicro syringe, nanomicro needle, molecular therapy, therapeutic efficiency, cancer

  8. A Comparison of Protein Stability in Prefillable Syringes Made of Glass and Plastic.

    Science.gov (United States)

    Waxman, Lloyd; Vilivalam, Vinod D

    2017-01-01

    The development of protein therapeutics requires stabilization of these labile molecules during shipment and storage. Biologics, particularly monoclonal antibodies, are frequently packaged at high concentration in prefillable syringes traditionally made of glass. However, some biologics are unstable in glass due to sensitivity to silicone oil, tungsten, glue, or metal ions. Syringes made from the plastic cyclic olefin polymer, Daikyo Crystal Zenith® (CZ), with a Flurotec-laminated piston, have none of these issues. This study compared the stability of several proteins including biotherapeutics when stored up to 14 months at 5 °C and 25 °C in prefillable siliconized syringes made of glass or silicone oil-free CZ syringes, and when subjected to mild agitation by end-over-end rotation at room temperature. At each time point, proteins were analyzed by several techniques including turbidity, size exclusion high-performance liquid chromatography, reversed phase high-performance liquid chromatography, ion-exchange chromatography, electrophoresis, and light scattering to monitor changes in aggregation and degradation. The results show that proteins have comparable stability when stored in glass syringes or in syringes made of CZ sterilized by E-beam or autoclave. In addition, proteins stressed by agitation were generally more stable and aggregated less in syringes made of CZ than in ones made of glass. LAY ABSTRACT: Biotherapeutic protein drugs such as monoclonal antibodies are frequently packaged at high concentration in prefillable syringes, which allows the drug to be directly administered by the patient or caregiver. Protein drugs, or biologics, can be unstable, and may aggregate, particularly when shaken. These aggregates can be immunogenic, stimulating the body's immune system to produce antibodies that can reduce the drug's efficacy. Although prefillable syringes are traditionally made of glass, some biologics are unstable in glass syringes due to the presence of

  9. Direct Evidence of Egestion and Salivation of Xylella fastidiosa Suggests Sharpshooters Can Be "Flying Syringes".

    Science.gov (United States)

    Backus, Elaine A; Shugart, Holly J; Rogers, Elizabeth E; Morgan, J Kent; Shatters, Robert

    2015-05-01

    Xylella fastidiosa is unique among insect-transmitted plant pathogens because it is propagative but noncirculative, adhering to and multiplying on the cuticular lining of the anterior foregut. Any inoculation mechanism for X. fastidiosa must explain how bacterial cells exit the vector's stylets via the food canal and directly enter the plant. A combined egestion-salivation mechanism has been proposed to explain these unique features. Egestion is the putative outward flow of fluid from the foregut via hypothesized bidirectional pumping of the cibarium. The present study traced green fluorescent protein-expressing X. fastidiosa or fluorescent nanoparticles acquired from artificial diets by glassy-winged sharpshooters, Homalodisca vitripennis, as they were egested into simultaneously secreted saliva. X. fastidiosa or nanoparticles were shown to mix with gelling saliva to form fluorescent deposits and salivary sheaths on artificial diets, providing the first direct, conclusive evidence of egestion by any hemipteran insect. Therefore, the present results strongly support an egestion-salivation mechanism of X. fastidiosa inoculation. Results also support that a column of fluid is transiently held in the foregut without being swallowed. Evidence also supports (but does not definitively prove) that bacteria were suspended in the column of fluid during the vector's transit from diet to diet, and were egested with the held fluid. Thus, we hypothesize that sharpshooters could be true "flying syringes," especially when inoculation occurs very soon after uptake of bacteria, suggesting the new paradigm of a nonpersistent X. fastidiosa transmission mechanism.

  10. Botulinum Toxin Therapy: Is Syringe Type Related to Cost-Effectiveness?

    Science.gov (United States)

    Foglietti, Mark Anthony; Wright, Lauren; Foglietti-Fostyk, Alanna

    2018-03-01

    Clostridium botulinum toxin is effective through cleaving presynaptic proteins at the neuromuscular junction, which prevents the release of acetylcholine and inhibits muscle contraction. Several serotypes of botulinum toxin (BT) exist; however, only 2 types have been approved by the US Food and Drug Administration for commercial and medical use, A and B. Both types of BT must be administered intramuscularly with a syringe, but the type of syringe is the injector's preference. Which syringe type is most efficient in minimizing product waste and most cost-effective for the patient and provider? We performed a single-center, open-label, analytical study using BT therapy and 2 types of syringes for analytics of cost-effectiveness. OnabotulinumtoxinA was the neuromodulator used in this report. Vials (100 U) of BT A were each reconstituted with 2.5 mL of 0.9% sodium chloride, for a final concentration of 4 U/0.1 mL. High-dead-space syringes are compared with low-dead-space syringes: 1-mL tuberculin (TB) luer slip syringe with detachable 25-gauge needle and 1-mL ultrafine insulin syringe with an attached 31-gauge needle, respectively. After each syringe was evacuated, the TB syringe was noted to contain 0.05 mL of the remaining product in the hub. Providers are discarding approximately 2 U of BT per TB syringe product injection. If the physician uses 30 syringes per day, 3 days a week, for 1 year, it equals to a lost revenue of approximately $155,500 per year. To individualize the cost-effective analysis, average quantity of syringes used per patient and overall patient volume must be considered, with corresponding adjustment of cost and units discarded. The American Society of Plastic Surgeons reported that the use of neuromodulators has increased by approximately 797% from 2000 to 2016. During that period, the price of neuromodulators has also increased by approximately 85%. Considering these statistics, the type of syringe used for BT neuromodular injection is a

  11. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  12. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  13. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  14. The measurement of activity in vials and syringes using a radionuclide assay calibrator

    International Nuclear Information System (INIS)

    Hooper, S.A.; Davies, I.H.

    1993-01-01

    To enable accurate measurements of the activity in both vials and syringes, a series of measurements was undertaken to ascertain the changes in response with geometry in nine isotope assay calibrators. From these measurements, two jigs were made for each calibrator to enable (a) optimal measurement of activity in vials and (b) optimal measurement of activity in a variety of syringe sizes. (Author)

  15. The pneumatic syringe: a simple apparatus for self-administration of drugs by rats.

    Science.gov (United States)

    Weeks, J R

    1977-12-01

    Drug solution is delivered by a syringe operated by a pneumatic cylinder. Recommended delivery volumes are from 10 to 200 microliter. A solid-state control unit is described which can operate two syringes (drug injection and flush), has outputs for recording responses and injections, and can be programmed to provide several schedules of reinforcement. All components are readily commercially available.

  16. The Washington Needle Depot: fitting healthcare to injection drug users rather than injection drug users to healthcare: moving from a syringe exchange to syringe distribution model

    Directory of Open Access Journals (Sweden)

    Glickman Andrea

    2010-01-01

    Full Text Available Abstract Needle exchange programs chase political as well as epidemiological dragons, carrying within them both implicit moral and political goals. In the exchange model of syringe distribution, injection drug users (IDUs must provide used needles in order to receive new needles. Distribution and retrieval are co-existent in the exchange model. Likewise, limitations on how many needles can be received at a time compel addicts to have multiple points of contact with professionals where the virtues of treatment and detox are impressed upon them. The centre of gravity for syringe distribution programs needs to shift from needle exchange to needle distribution, which provides unlimited access to syringes. This paper provides a case study of the Washington Needle Depot, a program operating under the syringe distribution model, showing that the distribution and retrieval of syringes can be separated with effective results. Further, the experience of IDUs is utilized, through paid employment, to provide a vulnerable population of people with clean syringes to prevent HIV and HCV.

  17. Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator

    CERN Document Server

    Tyler, D K

    2002-01-01

    The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

  18. Methods To Determine the Silicone Oil Layer Thickness in Sprayed-On Siliconized Syringes.

    Science.gov (United States)

    Loosli, Viviane; Germershaus, Oliver; Steinberg, Henrik; Dreher, Sascha; Grauschopf, Ulla; Funke, Stefanie

    2018-01-01

    The silicone lubricant layer in prefilled syringes has been investigated with regards to siliconization process performance, prefilled syringe functionality, and drug product attributes, such as subvisible particle levels, in several studies in the past. However, adequate methods to characterize the silicone oil layer thickness and distribution are limited, and systematic evaluation is missing. In this study, white light interferometry was evaluated to close this gap in method understanding. White light interferometry demonstrated a good accuracy of 93-99% for MgF 2 coated, curved standards covering a thickness range of 115-473 nm. Thickness measurements for sprayed-on siliconized prefilled syringes with different representative silicone oil distribution patterns (homogeneous, pronounced siliconization at flange or needle side, respectively) showed high instrument (0.5%) and analyst precision (4.1%). Different white light interferometry instrument parameters (autofocus, protective shield, syringe barrel dimensions input, type of non-siliconized syringe used as base reference) had no significant impact on the measured average layer thickness. The obtained values from white light interferometry applying a fully developed method (12 radial lines, 50 mm measurement distance, 50 measurements points) were in agreement with orthogonal results from combined white and laser interferometry and 3D-laser scanning microscopy. The investigated syringe batches (lot A and B) exhibited comparable longitudinal silicone oil layer thicknesses ranging from 170-190 nm to 90-100 nm from flange to tip and homogeneously distributed silicone layers over the syringe barrel circumference (110- 135 nm). Empty break-loose (4-4.5 N) and gliding forces (2-2.5 N) were comparably low for both analyzed syringe lots. A silicone oil layer thickness of 100-200 nm was thus sufficient for adequate functionality in this particular study. Filling the syringe with a surrogate solution including short

  19. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  20. [Trial manufacture of a plunger shield for a disposable plastic syringe].

    Science.gov (United States)

    Murakami, Shigeki; Emoto, Takashi; Mori, Hiroshige; Fujita, Katsuhisa; Kubo, Naoki

    2008-08-20

    A syringe-type radiopharmaceutical being supplied by a manufacturer has a syringe shield and a plunger shield, whereas an in-hospital labeling radiopharmaceutical is administered by a disposable plastic syringe without the plunger shield. In cooperation with Nihon Medi-Physics Co. Ltd., we have produced a new experimental plunger shield for the disposable plastic syringe. In order to evaluate this shielding effect, we compared the leaked radiation doses of our plunger shield with those of the syringe-type radiopharmaceutical (Medi shield type). Our plunger shield has a lead plate of 21 mm in diameter and 3 mm thick. This shield is equipped with the plunger-end of a disposal plastic syringe. We sealed 99mTc solution into a plastic syringe (Terumo Co.) of 5 ml with our plunger shield and Medi shield type of 2 ml. We measured leaked radiation doses around syringes using fluorescent glass dosimeters (Dose Ace). The number of measure points was 18. The measured doses were converted to 70 microm dose equivalent at 740 MBq of radioactivity. The results of our plunger shield and the Medi shield type were as follows: 4-13 microSv/h and 3-14 microSv/h at shielding areas, 3-545 microSv/h and 6-97 microSv/h at non-shielding areas, 42-116 microSv/h and 88-165 microSv/h in the vicinity of the syringe shield, and 1071 microSv/h and 1243 microSv/h at the front of the needle. For dose rates of shielding areas around the syringe, the shielding effects were approximately the same as those of the Medi shield type. In conclusion, our plunger shield may be useful for reducing finger exposure during the injection of an in-hospital labeled radiopharmaceutical.

  1. Flow pumping system for physiological waveforms.

    Science.gov (United States)

    Tsai, William; Savaş, Omer

    2010-02-01

    A pulsatile flow pumping system is developed to replicate flow waveforms with reasonable accuracy for experiments simulating physiological blood flows at numerous points in the body. The system divides the task of flow waveform generation between two pumps: a gear pump generates the mean component and a piston pump generates the oscillatory component. The system is driven by two programmable servo controllers. The frequency response of the system is used to characterize its operation. The system has been successfully tested in vascular flow experiments where sinusoidal, carotid, and coronary flow waveforms are replicated.

  2. Barriers to Access to Sterile Syringes as Perceived by Pharmacists and Injecting Drug Users: Implications for Harm Reduction in Lebanon.

    Science.gov (United States)

    Ghaddar, Ali; Nassar, Karine; Elsoury, Ghadier

    2017-09-19

    Access to sterile syringes to injecting drug users (IDU) reduces sharing behavior and prevents the transmission of HIV. To describe the barriers to access to sterile syringes for IDUs in Lebanon from the perspectives of pharmacists and IDUs. in this qualitative study conducted in Lebanon, data were collected from 72 syringe purchase tests at pharmacies, 64 interviewees with pharmacists and 2 focus groups with injecting drug users. Two independent researchers analyzed the verbatim transcripts. Results revealed that pharmacists often deny access to sterile syringes to IDUs who are frequently stigmatized and intimidated at pharmacies. While no large gender differences in pharmacists' attitudes and practices were observed, inequalities in syringe access were noticed with men IDUs more often denied purchase. Pharmacists had several barriers to sell syringes to IDUs including fear of disease spread, increased drug use, inappropriately discarded syringes, staff and customer safety, and business concerns. IDUs had several challenges to purchase syringes including stigmatization, intimidation, physical harassment, concern to reveal identity, fear of arrest and syringe price abuse. Identifying the barriers to and facilitators of access to sterile syringes to IDUs is important to guide the development of efficient policies. Findings implicate the importance of empowering IDUs to purchase syringes at pharmacies through reducing the negative attitude towards IDUs and strengthening pharmacists' role in the promotion of health of IDUs. Findings also suggest that the habit of syringe sharing would decrease if the legal and cultural barriers to access are reduced.

  3. Insulin appearance of subcutaneously infused insulin: influence of the basal rate pulse interval of the infusion pump.

    Science.gov (United States)

    Birch, K; Hildebrandt, P; Jensen, B M; Kühl, C; Brange, J

    1985-05-01

    To compare the metabolic control and the pharmacokinetics of infused insulin using an insulin pump (Auto-Syringe AS 6C) which provides the basal rate in pulses every 2-10 min with a pump (Medix Syringe Driver 209) providing the basal rate in pulses every 15-60 min, 6 C-peptide negative diabetic patients received, in random order, identical, but individual, insulin treatment during one 4-day period using the Auto-Syringe pump and another 4-day period using the Medix pump. On the fourth day of each period, blood glucose and plasma-free insulin were estimated every 30 min for 7 hr and every 5 min for the next hour. Plasma-free insulin was significantly higher on 3 time points out of the 26 possible when using the Medix pump, but this was not reflected in the blood glucose concentrations which were similar in the 2 periods. The results indicate that, from a metabolic and pharmacokinetic point of view, insulin pumps working with larger intervals between the basal rate pulses are just as good as the more technically advanced and hence often more expensive pumps which provide the basal rate in more and smaller pulses.

  4. Commentary on Vorobjov et al., "Comparison of injection drug users who obtain syringes from pharmacies and syringe exchange programs in Tallinn, Estonia"

    Directory of Open Access Journals (Sweden)

    Werb Daniel

    2009-01-01

    Full Text Available Abstract Recent data suggest that globally, between 5% and 10% of all new HIV cases are the result of unsafe injecting practices, and experts agree that reducing these practices is key to tackling the spread of HIV. And yet, despite the overwhelming evidence that providing sterile syringes to injection drug users (IDU through syringe exchange programs (SEPs or other means is an effective way of reducing HIV transmission among high-risk subpopulations, IDU in most settings still do not have access to sterile injecting equipment or if they do, access remains too restricted to effectively reduce the risk of HIV transmission. Vorobjov and colleagues have presented in this journal an interesting and timely study from Estonia comparing individuals who obtain syringes from SEPs and those who obtain syringes from pharmacies. As the authors point out, Estonia faces an unacceptably high HIV incidence rate of 50 new HIV cases per 100,000, this rate driven primarily by injection drug use. As such, the authors argue that Estonia's SEP network does not have the capacity to serve a growing IDU population at risk of transmitting HIV and pharmacy dispensation of clean syringes may be one potential approach to decreasing syringe sharing among high-risk injectors. It may be overly optimistic to consider the impact of higher threshold interventions such as pharmacy-based SEPs, given that IDU populations that engage in HIV risk behaviours such as syringe sharing are often hidden or hard to reach. Despite the need for a cautious approach, however, the findings presented by Vorobjov et al. may chart one potential course towards a more comprehensive societal response to reducing the health harms associated with injection drug use.

  5. Variation in polydispersity in pump- and pressure-driven micro-droplet generators

    Science.gov (United States)

    Zeng, Wen; Jacobi, Ian; Li, Songjing; Stone, Howard A.

    2015-11-01

    The polydispersity of droplets produced in a typical T-junction microfluidic channel under both syringe-pump-driven and pressure-driven flow configurations is measured quantitatively. Both flow systems exhibit high-frequency flow fluctuations that result in an intrinsic polydispersity due to the mechanism of droplet generation. In addition to this intrinsic polydispersity, the syringe-pump-driven device also exhibits low-frequency fluctuations due to mechanical oscillations of the pump, which overwhelm the high-frequency flow fluctuations and produce a signficantly heightened level of polydispersity. The quantitative difference in polydispersity between the two configurations and time-resolved measurements of individual droplet sizes are presented in order to enable the design of better flow control systems for droplet production.

  6. Fluidic pumps

    International Nuclear Information System (INIS)

    Priestman, G.H.

    1990-01-01

    A fluidic pump has primary and secondary vessels connected by a pipe, a displacement vessel having liquid to be delivered through a pipe via a rectifier provided with a feed tank. A drive unit delivers pressure fluid to a line to raise liquid and compress trapped gas or liquid in the space, including the pipe between the liquids in the two vessels and thus drive liquid out of the displacement vessel. The driving gas is therefore separated by the barrier liquid and the trapped gas or liquid from the liquid to be pumped which liquid could be e.g. radioactive. (author)

  7. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  8. Syringe Sharing Among a Prospective Cohort of Street-Involved Youth: Implications for Needle Distribution Programs.

    Science.gov (United States)

    Bozinoff, Nikki; Wood, Evan; Dong, Huiru; Richardson, Lindsey; Kerr, Thomas; DeBeck, Kora

    2017-09-01

    The sharing of previously used syringes is associated with the transmission of Hepatitis C and HIV. This longitudinal study examines syringe borrowing and syringe lending within a prospective cohort of street-involved youth in Vancouver, Canada. From September 2005 to May 2014, data were collected from the At-Risk Youth Study, a cohort of street-involved youth age 14-26 at enrollment, and analyzed using generalized estimating equations. Among 505 participants, 142 (28.1%) reported syringe borrowing and 132 (26.1%) reported syringe lending during the study period. In separate multivariable analyses, having difficulty finding clean needles and homelessness were significantly associated with syringe borrowing (Adjusted Odds Ratio (AOR) = 2.28, 95% CI 1.66-3.12 and AOR = 1.52, CI 1.05-2.21, respectively) and syringe lending (AOR = 1.89, 95% CI 1.32-2.71 and AOR = 1.65, 95% CI 1.11-2.44, respectively) (all p values people is warranted.

  9. Epinephrine syringe exchange events in a paediatric cardiovascular ICU: analysing the storm.

    Science.gov (United States)

    Achuff, Barbara-Jo; Achuff, Jameson C; Park, Hwan H; Moffett, Brady; Acosta, Sebastian; Rusin, Craig G; Checchia, Paul A

    2018-03-01

    Introduction Haemodynamically unstable patients can experience potentially hazardous changes in vital signs related to the exchange of depleted syringes of epinephrine to full syringes. The purpose was to determine the measured effects of epinephrine syringe exchanges on the magnitude, duration, and frequency of haemodynamic disturbances in the hour after an exchange event (study) relative to the hours before (control). Materials and methods Beat-to-beat vital signs recorded every 2 seconds from bedside monitors for patients admitted to the paediatric cardiovascular ICU of Texas Children's Hospital were collected between 1 January, 2013 and 30 June, 2015. Epinephrine syringe exchanges without dose/flow change were obtained from electronic records. Time, magnitude, and duration of changes in systolic blood pressure and heart rate were characterised using Matlab. Significant haemodynamic events were identified and compared with control data. In all, 1042 syringe exchange events were found and 850 (81.6%) had uncorrupted data for analysis. A total of 744 (87.5%) exchanges had at least 1 associated haemodynamic perturbation including 2958 systolic blood pressure and 1747 heart-rate changes. Heart-rate perturbations occurred 37% before exchange and 63% after exchange, and 37% of systolic blood pressure perturbations happened before syringe exchange, whereas 63% occurred after syringe exchange with significant differences found in systolic blood pressure frequency (pexchange events.

  10. Efficacy trial of Camouflage Syringe to reduce dental fear and anxiety.

    Science.gov (United States)

    Ujaoney, S; Mamtani, M; Thakre, T; Tote, J; Hazarey, V; Hazarey, P; Kulkarni, H

    2013-12-01

    Dental fear and anxiety in early childhood are widely prevalent and contribute to dental problems and behaviour in adulthood. Novel ways to reduce dental fear and anxiety in children are needed. Our aim was to conduct an efficacy trial of a novel Camouflage Syringe to reduce dental fear and anxiety in children. randomised controlled trial of efficacy of the Camouflage Syringe. We designed a Camouflage Syringe with a toy-like appearance that veils the conventional syringe to permit topical application and injection of local anaesthesia and ensure more involvement of the patient in the treatment process. We conducted a concurrent parallel, randomised controlled trial (NCT01398007) on the efficacy of this Camouflage Syringe to reduce the dental fear and anxiety in children seeking dental treatment who required the use of local anaesthesia. Using Venham's clinical rating scale, Venham's picture test, parental stress questionnaire and recall questionnaire, the efficacy of the Camouflage Syringe to reduce dental fear and anxiety ranged from 82% to 97% for various outcomes and from 60% to 100% for prevention of related adverse outcomes. For all outcomes, the number needed to treat was close to unity. Our results strongly favour the use of Camouflage Syringe to reduce dental fear and anxiety in children.

  11. Comparison of infusion pumps calibration methods

    Science.gov (United States)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  12. Study on the radiation effect of plastic syringe materials

    International Nuclear Information System (INIS)

    Byun, H.C.; Yun, B.M.; Kim, K.Y.; Kong, Y.K.; Park, H.Y.

    1983-01-01

    From the viewpoint of gammasterilization, the defects of domestic polypropylene as the syringe material are to get worse the mechanical properties and discoloration by irradiation. Therefore, the domestic polystyrene (GPPS 150) were inspected to use as substitute for the polypropylene. The gel point of the polystyrene was about 100Mrad and none momentous change of the mechanical properties were appeared until the dose reached to the point. Above the point, as the crosslinking reaction proceed both strength of tensile and impact were increased with discoloration. No significant problem was also found in the water extract test and chemical resistance test. In addition to the pure polystyrene, the copolymer of butadiene (HIPS 425) and the blend material of polypropylene were also inspected for the purpose and almost same results were obtained in the radiation irradiation. From the above result, it is considered that polystyrene and the copolymer and the blend mentioned above are available for the medical plastics which would be sterilized by gamma-radiation. (Author)

  13. Evaluation of syringe shield effectiveness in handling radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Cho Yong-In

    2015-01-01

    Full Text Available The purpose of this study was to evaluate the effectiveness of the radiation shield of radionuclide syringes and the personal dose equivalent by performing a simulation of radionuclides used in nuclear medicine diagnosis. In order to evaluate the dose depending on the distance between the radiation source and the ICRU sphere against the thickness of the shielding device, the distance at which a nuclear medicine worker may inadvertently come into contact with radiation from the radiation source was set at 0 cm to 30 cm according to the thickness of the shield, thus fixing the ICRU sphere. For a dose evaluation, Hp(10, Hp(3, and Hp(0.07 measurable in specific depth of the ICRU were evaluated. It was found that a dose measured on skin surface of nuclear medicine workers was relatively higher, that the dose varied in relation to the thickness of the radiation shield, and that the shielding effect decreased for some radiation sources such as 67Ga and 111In. It proved necessary to increase thickness of shielding device to the radiation sources such as 67Ga and 111In. It is also considered that a study of proper shielding thickness will be needed in future.

  14. Mechanized syringe homogenization of human and animal tissues.

    Science.gov (United States)

    Kurien, Biji T; Porter, Andrew C; Patel, Nisha C; Kurono, Sadamu; Matsumoto, Hiroyuki; Scofield, R Hal

    2004-06-01

    Tissue homogenization is a prerequisite to any fractionation schedule. A plethora of hands-on methods are available to homogenize tissues. Here we report a mechanized method for homogenizing animal and human tissues rapidly and easily. The Bio-Mixer 1200 (manufactured by Innovative Products, Inc., Oklahoma City, OK) utilizes the back-and-forth movement of two motor-driven disposable syringes, connected to each other through a three-way stopcock, to homogenize animal or human tissue. Using this method, we were able to homogenize human or mouse tissues (brain, liver, heart, and salivary glands) in 5 min. From sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis and a matrix-assisted laser desorption/ionization time-of-flight mass spectrometric enzyme assay for prolidase, we have found that the homogenates obtained were as good or even better than that obtained used a manual glass-on-Teflon (DuPont, Wilmington, DE) homogenization protocol (all-glass tube and Teflon pestle). Use of the Bio-Mixer 1200 to homogenize animal or human tissue precludes the need to stay in the cold room as is the case with the other hands-on homogenization methods available, in addition to freeing up time for other experiments.

  15. Syringe Decriminalization Advocacy in Red States: Lessons from the North Carolina Harm Reduction Coalition.

    Science.gov (United States)

    Cloud, David H; Castillo, Tessie; Brinkley-Rubinstein, Lauren; Dubey, Manisha; Childs, Robert

    2018-05-08

    Syringe access programs (SAPs) are cornerstone harm reduction interventions for combatting the national opioid epidemic. The goal of this paper is to describe effective advocacy strategies for enacting syringe decriminalization legislation to foster the expansion of SAPs in high-need areas amidst political opposition. Decades or research shows that SAPs prevent the transmission of HIV among people who inject drugs (PWID) and are a cost-effective tool for linking PWID to medical care, health education, and social services. In the USA, state laws criminalizing distribution and possession of syringes impede the expansion of SAPs into areas where they are sorely needed. In 2016, North Carolina became the first state to legalize SAPs with a Republican super majority. This paper distills strategies for community organizations seeking to advance syringe decriminalization legislation in politically conservative states with histories of prioritizing punitive sanctions over public health responses to drug use.

  16. Syringe vending machines for injection drug users: an experiment in Marseille, France.

    Science.gov (United States)

    Obadia, Y; Feroni, I; Perrin, V; Vlahov, D; Moatti, J P

    1999-01-01

    OBJECTIVES: This study evaluated the usefulness of vending machines in providing injection drug users with access to sterile syringes in Marseille, France. METHODS: Self-administered questionnaires were offered to 485 injection drug users obtaining syringes from 32 pharmacies, 4 needle exchange programs, and 3 vending machines. RESULTS: Of the 343 respondents (response rate = 70.7%), 21.3% used the vending machines as their primary source of syringes. Primary users of vending machines were more likely than primary users of other sources to be younger than 30 years, to report no history of drug maintenance treatment, and to report no sharing of needles or injection paraphernalia. CONCLUSIONS: Vending machines may be an appropriate strategy for providing access to syringes for younger injection drug users, who have typically avoided needle exchange programs and pharmacies. PMID:10589315

  17. Direct observation of syringeal muscle function in songbirds and a parrot

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Goller, Franz

    2002-01-01

    on the syrinx. Contraction of m. tracheobronchialis ventralis enlarges the syringeal lumen and thus increases airflow by abducting the LL but does not affect the ML. The largest syringeal muscle, m. syringealis ventralis, plays a minor role, if any, in direct aperture control and thus in gating airflow...... the LTMs further into the tracheal lumen but does not close the syringeal aperture fully. The intrinsic deep muscle, m. syringealis profundus, abducts the LTMs through cranio-laterad movement of a paired, protruding half-ring. The weakly developed extrinsic m. sternotrachealis seems to increase tension......The role of syringeal muscles in controlling the aperture of the avian vocal organ, the syrinx, was evaluated directly for the first time by observing and filming through an endoscope while electrically stimulating different muscle groups of anaesthetised birds. In songbirds (brown thrashers...

  18. Variability in syringe components and its impact on functionality of delivery systems.

    Science.gov (United States)

    Rathore, Nitin; Pranay, Pratik; Eu, Bruce; Ji, Wenchang; Walls, Ed

    2011-01-01

    Prefilled syringes and autoinjectors are becoming increasingly common for parenteral drug administration primarily due to the convenience they offer to the patients. Successful commercialization of such delivery systems requires thorough characterization of individual components. Complete understanding of various sources of variability and their ranking is essential for robust device design. In this work, we studied the impact of variability in various primary container and device components on the delivery forces associated with syringe injection. More specifically, the effects of barrel size, needle size, autoinjector spring force, and frictional forces have been evaluated. An analytical model based on underlying physics is developed that can be used to fully characterize the design space for a product delivery system. Use of prefilled syringes (syringes prefilled with active drug) is becoming increasingly common for injectable drugs. Compared to vials, prefilled syringes offer higher dose accuracy and ease of use due to fewer steps required for dosage. Convenience to end users can be further enhanced through the use of prefilled syringes in combination with delivery devices such as autoinjectors. These devices allow patients to self-administer the drug by following simple steps such as pressing a button. These autoinjectors are often spring-loaded and are designed to keep the needle tip shielded prior to injection. Because the needle is not visible to the user, such autoinjectors are perceived to be less invasive than syringes and help the patient overcome the hesitation associated with self-administration. In order to successfully develop and market such delivery devices, we need to perform an in-depth analysis of the components that come into play during the activation of the device and dose delivery. Typically, an autoinjector is activated by the press of a button that releases a compressed spring; the spring relaxes and provides the driving force to push the

  19. Solar Pump

    Science.gov (United States)

    Pique, Charles

    1987-01-01

    Proposed pump moves liquid by action of bubbles formed by heat of sun. Tube of liquid having boiling point of 100 to 200 degrees F placed at focal axis of cylindrical reflector. Concentrated sunlight boils liquid at focus, and bubbles of vapor rise in tube, carrying liquid along with them. Pressure difference in hot tube sufficient to produce flow in large loop. Used with conventional flat solar heating panel in completely solar-powered heat-storage system.

  20. Retraction of the Plunger on a Syringe of Hyaluronic Acid Before Injection: Are We Safe?

    Science.gov (United States)

    Carey, Wayne; Weinkle, Susan

    2015-12-01

    Controversy exists concerning the need for aspiration before injection with hyaluronic acid (HA) fillers. The authors undertook a study of HA products to determine if blood could be aspirated back into a syringe of HA when the needle has been primed or filled with HA. Two studies were set up to determine if or when blood could be withdrawn from a heparinized fresh tube of blood into the HA syringe. Two different techniques were tested; one using a slow-pull retraction of the plunger and up to a 5-second waiting time before release versus a rapid pullback and quick release. Review of these data demonstrates that the usual clinical method, which involves quick withdrawal and instant release of the syringe plunger does not allow for sufficient removal of the filler found intraluminal in the needle and may give rise to false negative results in vitro and likely in vivo with the exception being the Galderma/Medicis products. In summary, withdrawal of the syringe plunger with no visible blood in the syringe does not eliminate the possibility of intravascular placement of the syringe needle.

  1. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  2. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  3. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  4. High dead-space syringe use among people who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Rafful, Claudia; Zule, William; González-Zúñiga, Patricia E; Werb, Dan; Medina-Mora, María Elena; Magis-Rodriguez, Carlos; Strathdee, Steffanie A

    2015-05-01

    High dead-space syringes (HDSS) are believed to confer an elevated risk of acquiring HIV and other blood-borne infections. We identified prevalence and correlates of HDSS use among injection drug users (IDU) in Tijuana, Mexico, where syringe purchase and possession is legal without a prescription. Beginning in 2011, IDU who reported being 18 years or older and injected drugs within the last month were recruited into a prospective study. At baseline and semi-annually, 557 IDU underwent HIV-testing and interviewer-administered surveys. Logistic regression was used to identify correlates of using HDSS. Of 557 IDU, 40% had ever used HDSS, mostly because no other syringe type was available (72%), or because they were easier to get (20%). Controlling for sex and age at first injection, use of HDSS was associated with cocaine as the first drug injected (Adjusted Odds Ratio [AOR]: 2.68; Confidence Interval 95% [CI]: 1.15-6.22), having been stopped or arrested by police (AOR: 1.84; 95% CI: 1.11-3.07), being deported from the US (AOR: 1.64; 95% CI:1.06-2.53), and believing it is illegal to carry syringes (AOR:1.78; 95% CI: 1.01-3.15). Use of HDSS is surprisingly common among IDU in Tijuana. Efforts are needed to expand coverage of low-dead space syringes through existing syringe exchange programs. Education is required to increase awareness of the harms associated with HDSS, and to inform IDU that syringe possession is legal across Mexico.

  5. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  6. Decreased Odds of Injection Risk Behavior Associated With Direct Versus Indirect Use of Syringe Exchange: Evidence From Two California Cities.

    Science.gov (United States)

    Behrends, Czarina N; Li, Chin-Shang; Gibson, David R

    2017-07-29

    While there is substantial evidence that syringe exchange programs (SEPs) are effective in preventing HIV among people who inject drugs (PWID), nearly all the evidence comes from PWID who obtain syringes from an SEP directly. Much less is known about the benefits of secondary exchange to PWID who get syringes indirectly from friends or acquaintances who visit an SEP for them. We evaluated the effectiveness of direct versus indirect syringe exchange in reducing HIV-related high-risk injecting behavior among PWID in two separate studies conducted in Sacramento and San Jose, California, cities with quite different syringe exchange models. In both studies associations between direct and indirect syringe exchange and self-reported risk behavior were examined with multivariable logistic regression models. Study 1 assessed effects of a "satellite" home-delivery syringe exchange in Sacramento, while Study 2 evaluated a conventional fixed-site exchange in San Jose. Multivariable analyses revealed 95% and 69% reductions, respectively, in high-risk injection associated with direct use of the SEPs in Sacramento and San Jose, and a 46% reduction associated with indirect use of the SEP in Sacramento. Conclusions/Importance: The very large effect of direct SEP use in Sacramento was likely due in part to home delivery of sterile syringes. While more modest effects were associated with indirect use, such use nevertheless is valuable in reducing the risk of HIV transmission of PWID who are unable or unwilling to visit a syringe exchange.

  7. Internal pump

    International Nuclear Information System (INIS)

    Kushima, Jun; Hayashi, Youjiro; Ueda, Masayuki.

    1997-01-01

    The present invention relates to an internal pump. A water hole allowing communication between internal and external circumferences of a stretch tube is provided at the portion of the stretch tube corresponding to a position where an end face of a nozzle portion of a motor case and an end face of a diffuser are joined with each other so that hot filtered water inside a pressure container which has entered from where the end face of the nozzle portion of the motor case and the end face of the diffuser are joined with each other is combined with the purged water so that it can be sent back to the pressure container again. (author) figs

  8. Influence of Syringe Volume on Foam Stability in Sclerotherapy for Varicose Vein Treatment.

    Science.gov (United States)

    Bai, Taoping; Jiang, Wentao; Fan, Yubo

    2018-05-01

    Despite the popularity of sclerotherapy for treating varicose veins, it still exhibits various problems, such as pulmonary embolism, deep-vein thrombosis, phlebitis, and visual disorders. To investigate syringe volume influence on foam stability, obtain the foam decay rule, and provide a reference for clinics. Five types of syringes are used to prepare foam at room temperature with various liquid-gas ratios. Foam decay process experiments were performed 5 times and recorded by video. The stability indices used include drainage time, half-life, bubble diameter, bubble surface density, and drainage rate. The 30 and 2-mL syringes, respectively, recorded the highest and lowest drainage speeds. Foam drainage time and half-life, differences varied between 15 and 70 seconds, and 20 and 100 seconds, respectively. Foam bubble diameters were distributed over 0.1 to 2.0 mm with roughly 200 to 700 bubbles per square centimeter. Increased syringe volume causes the bubble diameter to increase. Thus, foam dispersion increases and foam half-life decreases; hence, foam becomes unstable. It is, thus, better to use a small syringe several times to prepare foam in clinics using segmented injections.

  9. A syringe-sharing model for the spread of HIV: application to Omsk, Western Siberia.

    Science.gov (United States)

    Artzrouni, Marc; Leonenko, Vasiliy N; Mara, Thierry A

    2017-03-01

    A system of two differential equations is used to model the transmission dynamics of human immunodeficiency virus between 'persons who inject drugs' (PWIDs) and their syringes. Our vector-borne disease model hinges on a metaphorical urn from which PWIDs draw syringes at random which may or may not be infected and may or may not result in one of the two agents becoming infected. The model's parameters are estimated with data mostly from the city of Omsk in Western Siberia. A linear trend in PWID prevalence in Omsk could only be fitted by considering a time-dependent version of the model captured through a secular decrease in the probability that PWIDs decide to share a syringe. A global sensitivity analysis is performed with 14 parameters considered random variables in order to assess their impact on average numbers infected over a 50-year projection. With obvious intervention implications the drug injection rate and the probability of syringe-cleansing are the only parameters whose coefficients of correlations with numbers of infected PWIDs and infected syringes have an absolute value close to or larger than 0.40. © The authors 2015. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  10. Geothermal heat pumps - gaining ground in the UK and worldwide

    International Nuclear Information System (INIS)

    Curtis, Robin

    2001-01-01

    This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed

  11. Breastfeeding FAQs: Pumping

    Science.gov (United States)

    ... of pump is best? You can buy or rent a breast pump from lactation consultants, hospitals, retail ... place to do it. Many companies offer their employees pumping and nursing areas. If yours doesn't, ...

  12. A review of the security of insulin pump infusion systems.

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-11-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.

  13. Accelerator programme at CAT

    International Nuclear Information System (INIS)

    Ramamurthi, S.S.

    1991-01-01

    The Accelerator Programme at the Centre for Advanced Technology (CAT), Indore, has very broad based concept under which all types of accelerators are to be taken up for design and fabrication. This centre will be housing a wide variety of accelerators to serve as a common facility for the universities, national laboratories in addition to laboratories under the Department of Atomic Energy. In the first phase of the programme, a series of electron accelerators are designed and fabricated. They are synchrotron radiation sources of 450 MeV (INDUS-I) and of 2 GeV (INDUS-II), microtron upto energy of 20 MeV, linear accelerator upto 20 MeV, and DC Accelerator for industrial irradiation upto 750 KeV and 20 KW. A proton accelerator of 300 MeV with 20 MeV linac injector is also designed. CAT is also developing a strong base for support technologies like ultra high vacuum, radio frequency and microwaves, DC pulsed and superconducting magnets, power supplies and controls etc. These technologies are very useful for other industrial applications also. To develop user groups to utilise INDUS-II synchrotron radiation source, a batch production of rotating Anode X-ray generators with power supplies has been initiated. So also, the sputter ion pumps, electron guns, turbo molecular pumps are brought into batch production. (author)

  14. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  15. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  16. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  17. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  18. Legal syringe purchases by injection drug users, Brooklyn and Queens, New York City, 2000-2001.

    Science.gov (United States)

    Des Jarlais, Don C; McKnight, Courtney; Friedmann, Patricia

    2002-01-01

    To assess preliminary results of the Expanded Syringe Access Demonstration Program (ESAP) in New York City. Temporal trends of pharmacy use among injection drug users (IDUs) in Brooklyn and Queens were analyzed from December 2000 through December 2001. Brooklyn and Queens, New York City. PARTIPANTS: IDUs. Attempts to purchase syringes from pharmacies and success in doing so. Of the 1,072 IDUs interviewed from December 2000 through December 2001, the majority were daily heroin injectors, but there was also substantial speedball and cocaine injection. There was a clear increase over time in both the percentage of subjects who attempted to purchase syringes in pharmacies and in the percentage who successfully purchased syringes. Among IDUs interviewed 4 or more months after ESAP began, large majorities of those who attempted to purchase syringes were successful in doing so. No differences in use of ESAP by IDUs were identified in Brooklyn versus Queens: 27% of IDUs interviewed in Queens reported that they had attempted to purchase syringes in pharmacies versus 28% in Brooklyn. Persons who reported injecting on a daily or more frequent basis were more likely to have attempted pharmacy purchases than persons who reported injecting less frequently, 32% versus 21%. The ESAP program has led to an increase in the use of pharmacies as sources of sterile injection equipment among IDUs in New York City. The extent to which pharmacies become an important source of sterile injection equipment and the effect of legal pharmacy sales on risk behaviors for human immunodeficiency virus (HIV) infection remain to be determined.

  19. The evaluation of a trial of syringe vending machines in Canberra, Australia.

    Science.gov (United States)

    McDonald, David

    2009-07-01

    Syringe vending machines (SVMs) have been trialled in Canberra, Australian Capital Territory, Australia, as an intervention aiming to increase the availability of sterile injecting equipment for use by IDUs. This study evaluated the 12-month trial. A utilisation-focused evaluation model, with both formative and summative components, was employed. Four SVMs were installed, each dispensing packs containing four 1 mL syringes and associated injecting paraphernalia. The trial participants were the clients of the SVMs and other key informants. The core measurements used were the number of syringes dispensed in Canberra by SVMs and other outlets, SVM clients' demographics and experiences of and attitudes towards SVMs, perceived impacts of SVMs on needle sharing, unsafe disposal of used syringes in the vicinity of SVMs, and community and stakeholder attitudes. The trial was implemented successfully, with no adverse consequences identified. The SVMs appear to be serving both the usual clients of the other outlets for sterile injecting equipment (community pharmacies and the Needle Syringe Program outlets) and others who are reluctant to use such outlets or find them inconvenient. The out-of-business-hours provision of syringes through the SVMs was particularly welcomed by both SVM clients and other stakeholders. The continuing operation of the initial four SVMs is widely supported, and additional machines are requested by clients and others. Owing to the success of the trial in terms of feasibility and outcomes for both IDUs and for the broader community, it is desirable that providing sterile injecting equipment through SVMs continues and be expanded as an integral component of harm reduction strategies.

  20. Negotiating access: social barriers to purchasing syringes at pharmacies in Tijuana, Mexico.

    Science.gov (United States)

    Davidson, Peter J; Lozada, Remedios; Rosen, Perth C; Macias, Armando; Gallardo, Manuel; Pollini, Robin A

    2012-07-01

    One common public health response to the emergence of HIV has been the provision of sterile syringes to people who inject drugs. In Mexico specialized syringe exchanges are rare, and the sale of needles through pharmacies is often the only way people who inject drugs can obtain sterile syringes. However, people who inject drugs in Tijuana, Mexico report considerable social barriers to successfully purchasing syringes at pharmacies. Between October 2008 and March 2009 we conducted seven in-depth focus groups with 47 people who inject drugs in Tijuana, Mexico. Focus group transcripts were analysed using a descriptive and thematic approach rooted in grounded theory. We found that injectors offered a number of explanations for why pharmacies were reluctant to sell them syringes, including fear of police; attitudes toward drug use; fear of stereotypical drug user behaviour such as petty theft, violence, or distressing behaviour; and related fears that an obvious drug using clientèle would drive away other customers. Injectors described a range of ways of attempting to re-frame or negotiate interactions with pharmacy staff so that these and related concerns were ameliorated. These included tactics as simple as borrowing cleaner clothing, through to strategies for becoming 'known' to pharmacy staff as an individual rather than as a member of a stigmatized group. Increasing the ability of pharmacy staff and people who inject drugs to successfully negotiate syringe sales are highly desirable. Interventions designed to improve this likelihood need to capitalize on existing solutions developed ad hoc by people who inject drugs and pharmacy staff, and should focus on broadening the range of 'identities' which pharmacy staff are able to accept as legitimate customers. Approaches to achieve this end might include sensitizing pharmacy staff to the needs of people who inject drugs; facilitating individual drug users meeting individual pharmacy staff; and working with drug users

  1. Evaluation and validation of a bee venom sting challenge performed by a micro-syringe.

    Science.gov (United States)

    Cortellini, Gabriele; Severino, Maurizio; Francescato, Elisabetta; Turillazzi, Stefano; Spadolini, Igino; Rogkakou, Anthi; Passalacqua, Giovanni

    2012-12-01

    The honeybee sting challenge is considered a reliable procedure to evaluate the efficacy of specific immunotherapy, but it is difficult and unpractical to perform in clinical practice, because live insects are required. To assess the feasibility and reliability of a challenge test using a micro-syringe, and compared the procedure with sting challenge. Patients on bee venom immunotherapy and without systemic reactions at field sting were enrolled. They underwent a sting challenge with live bee, and large local reactions were assessed up to 48 hours. Those patients displaying systemic reactions at the sting challenge were excluded from the syringe challenge for ethical reasons. The syringe challenge was done by injecting 0.5 μL fresh unfiltered bee venom at 2 mm depth (the length of the sting left by a bee). The same follow-up as at the first challenge was performed. Bee-specific immunoglobulin E (IgE) and tryptase were measured after each challenge. Nineteen patients underwent the sting challenge with live bees. Four had immediate systemic reactions (urticaria or asthma) and were excluded from the second challenge. The remaining 15 patients with large local reaction underwent the syringe challenge. No significant difference was seen in the maximum area of the large local reactions between the challenge with live bees and the syringe challenge. Also, no change was seen in tryptase and specific antibodies. This preliminary study suggests that the micro-syringe challenge with honeybee venom is feasible and produces results indistinguishable from those of the traditional sting challenge. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  2. Dry vacuum pumps

    International Nuclear Information System (INIS)

    Sibuet, R

    2008-01-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R and D/industries, merits over conventional pumps and future growth scope will be discussed

  3. Experience on vibration analysis of primary coolant pumps in Cirus

    International Nuclear Information System (INIS)

    Ullas, O.P.; Tilara, Manoj; Kharpate, A.V.

    2002-01-01

    Full text: 40 MW (thermal) CIRUS research reactor has been in operation for over four decades. During the major portion of its life almost all the major mechanical equipment operated continuously in a healthy condition. Since 1988 ageing related breakdown has been noticed in some of the critical components, PCW pumps being one of them. Vibration measurement and analysis is carried out on a routine basis as a part of conditioning monitoring programme. Ageing degradation of various components of the pump has been detected by such a performance monitoring programme. Conditioning monitoring has been found to be quite useful for scheduling of maintenance work on pumps

  4. Graphical user interface simplifies infusion pump programming and enhances the ability to detect pump-related faults.

    Science.gov (United States)

    Syroid, Noah; Liu, David; Albert, Robert; Agutter, James; Egan, Talmage D; Pace, Nathan L; Johnson, Ken B; Dowdle, Michael R; Pulsipher, Daniel; Westenskow, Dwayne R

    2012-11-01

    Drug administration errors are frequent and are often associated with the misuse of IV infusion pumps. One source of these errors may be the infusion pump's user interface. We used failure modes-and-effects analyses to identify programming errors and to guide the design of a new syringe pump user interface. We designed the new user interface to clearly show the pump's operating state simultaneously in more than 1 monitoring location. We evaluated anesthesia residents in laboratory and simulated environments on programming accuracy and error detection between the new user interface and the user interface of a commercially available infusion pump. With the new user interface, we observed the number of programming errors reduced by 81%, the number of keystrokes per task reduced from 9.2 ± 5.0 to 7.5 ± 5.5 (mean ± SD), the time required per task reduced from 18.1 ± 14.1 seconds to 10.9 ± 9.5 seconds and significantly less perceived workload. Residents detected 38 of 70 (54%) of the events with the new user interface and 37 of 70 (53%) with the existing user interface, despite no experience with the new user interface and extensive experience with the existing interface. The number of programming errors and workload were reduced partly because it took less time and fewer keystrokes to program the pump when using the new user interface. Despite minimal training, residents quickly identified preexisting infusion pump problems with the new user interface. Intuitive and easy-to-program infusion pump interfaces may reduce drug administration errors and infusion pump-related adverse events.

  5. Microbial contamination of syringes during preparation: the direct influence of environmental cleanliness and risk manipulations on end-product quality.

    Science.gov (United States)

    Stucki, Cyril; Sautter, Anna-Maria; Favet, Jocelyne; Bonnabry, Pascal

    2009-11-15

    The direct influence of environmental cleanliness and risk manipulations on prepared syringes was evaluated. Media-fill testing was used to estimate potential microbial contamination. Syringes were prepared in three different environments using four different uncontrolled high-risk manipulations. The three environments included an International Organization for Standardization (ISO) class 5 horizontal laminar-airflow hood in an ISO class 6 cleanroom (in accordance with United States Pharmacopeia [USP] chapter 797), an ISO class 7 drug preparation area of an operating room, and an uncontrolled decentralized pharmacy in a ward. For each combination of environment and manipulation, 100 syringes were filled by a single operator. The four high-risk manipulations used included simple filling of syringes with trypticase soy broth, three-second contact by the ungloved fingers of the operator with the hub of the syringe, three-second contact between an object and the hub of the syringe, and exposure of the filled syringes to ambient air for 10 minutes. Of the 1500 syringes prepared in three different environments, none produced within the cleanroom contained microorganisms, 6% were contaminated in the operating room, and 16% were contaminated in the ward (p ISO class 5 cleanroom in accordance with USP chapter 797 requirements was demonstrated to be the best way to avoid bacterial or fungal contamination of injectable drugs directly resulting in patient infections.

  6. Community Impact of Pharmacy-Randomized Intervention to Improve Access to Syringes and Services for Injection Drug Users

    Science.gov (United States)

    Crawford, Natalie D.; Amesty, Silvia; Rivera, Alexis V.; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M.

    2014-01-01

    Objectives: In an effort to reduce HIV transmission among injection drug users (IDUs), New York State deregulated pharmacy syringe sales in 2001 through the Expanded Syringe Access Program by removing the requirement of a prescription. With evidence suggesting pharmacists' ability to expand their public health role, a structural, pharmacy-based…

  7. Crispv programme

    International Nuclear Information System (INIS)

    Marinkovicj, N.

    CRISPV (Criticality and Spectrum code) is a multigroup neutron spectrum code for homogeneous reactor cores and is actually a somewhat modified version of the original CRISP programme. It is a combination of DATAPREP-II and BIGG-II programmes. It is assumed that the reactor cell is a cylindrical fuel rod in the light or heavy water moderator. DATEPREP-II CODE forms the multigroup data for homogeneous reactor and prepares the input parameters for the BIGG-II code. It has its own nuclear data library on a separate tape in binary mode. BIGG-II code is a multigroup neutron spectrum and criticality code for a homogenized medium. It has as well its own separate data library. In the CRISPV programme the overlay structure enables automatic handling of data calculated in the DATAPREP-II programme and needed in the BIGG-II core. Both programmes are written in FORTRAN for CDC 3600. Using the programme is very efficient and simple

  8. Solar Pumping : The Basics

    OpenAIRE

    World Bank Group

    2018-01-01

    Solar photovoltaic water pumping (SWP) uses energy from solar photovoltaic (PV) panels to power an electric water pump. The entire process, from sunlight to stored energy, is elegant and simple. Over last seven years, the technology and price of solar pumping have evolved dramatically and hence the opportunities it presents. Solar pumping is most competitive in regions with high solar inso...

  9. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  10. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  11. Programmable gain equalizer for multi-core fiber amplifiers

    NARCIS (Netherlands)

    Fontaine, N.K.; Guan, B.; Ryf, R.; Chen, H.; Koonen, A.M.J.; Ben Yoo, S.J.; Abedin, K.; Fini, J.; Taunay, T.F.; Neilson, D.T.

    2014-01-01

    We demonstrate a programmable gain equalizer for 7-core fiber that can independently equalize spectra or block wavelengths in each core across the C-band. It is spliced directly to a side-pumped multi-core amplifying fiber.

  12. Nonprescription naloxone and syringe sales in the midst of opioid overdose and hepatitis C virus epidemics: Massachusetts, 2015.

    Science.gov (United States)

    Stopka, Thomas J; Donahue, Ashley; Hutcheson, Marguerite; Green, Traci C

    To determine the prevalence of nonprescription naloxone and sterile syringe sales, factors associated with nonprescription sales, geospatial access to nonprescription naloxone and syringe-selling pharmacies, and targets for potential interventions. Cross-sectional study. Massachusetts has experienced steep increases in reported opioid overdoses and hepatitis C virus cases in the past decade. Pharmacists have the potential to play a substantial role in increasing access to nonprescription naloxone and sterile syringes, which can reverse opioid overdoses and decrease hepatitis C virus transmission, respectively. We completed brief telephone surveys with 809 of 1042 retail pharmacies across Massachusetts (response rate = 77.6%) during 2015 to assess experience with nonprescription sales of naloxone and sterile syringes. Our primary outcomes were the stocking and selling of naloxone in the pharmacy (yes or no) for nonprescription sales and nonprescription syringe sales (yes or no). We conducted multivariable regression analyses and created maps using a geographic information system to identify factors associated with nonprescription sales of naloxone and sterile syringes, and to improve our understanding of geospatial access to pharmacy-based naloxone and syringe sales. More than 97% of pharmacies reported selling sterile syringes without requiring a prescription, and 45% of pharmacies reported stocking and selling naloxone. Factors associated with nonprescription sales included hours of operation, experience with and interest in harm reduction activities, and presence in an opioid overdose hotspot. Geographic access to nonprescription sale of sterile syringes is widespread, whereas geospatial access to naloxone is limited. Training to understand the benefits, applications, and distribution needs of naloxone is of interest to surveyed pharmacists. Access to sterile syringes through nonprescription sales is strong across Massachusetts, and although more than 350

  13. Homicide by Sch from a syringe-like dart ejected by a compound crossbow.

    Science.gov (United States)

    Guo, Wei; Luo, Guochang; Wang, Hao; Meng, Xiangzhi

    2015-02-01

    The compound crossbow can be used to eject syringe-like dart loaded with poisonous solution. Succinylcholine (Sch) is a short-acting neuromuscular blocker medically used to achieve complete relaxation of muscle for a good intubation condition. Without the help of an artificial respirator, intramuscular injection of a large dose of Sch can paralyze the respiratory muscle and result in the receiver's death. In this paper, we present the homicide case of a young male killed by Sch from a syringe-like dart ejected by a compound crossbow. The subcutaneous and muscular hemorrhages observed around the entry were more severe than that caused by a medical injection. Additionally, other autopsy results showed the external appearance of a pinhole, general asphyxia signs and pathological findings which were not characteristic. The discovery of a syringe-like dart at the scene is the critical clue and reason for analyzing for Sch, which is commonly used to load syringe-like dart to paralyze and steal dog in the countryside of China. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  14. HIV Risk Behavior among Amphetamine Injectors at U.S. Syringe Exchange Programs

    Science.gov (United States)

    Braine, Naomi; Des Jarlais, Don C.; Goldblatt, Cullen; Zadoretzky, Cathy; Turner, Charles

    2005-01-01

    The goal of this study was to compare HIV risk behaviors of amphetamine and non-amphetamine injectors at syringe exchange programs (SEP) in the United States and to identify factors associated with injection risk. This analysis is based on data from a random cross-section of participants at 13 SEPs in different parts of the country. All interviews…

  15. An introduction to the Micrel Micropump MP Daily portable syringe driver.

    Science.gov (United States)

    Groves, Karen E

    2003-11-01

    In this article the author describes the Micrel Micropump MP Daily (MP Daily) portable syringe driver. This follows the author's experience of a 4-month pilot of the device by an inpatient palliative care unit. Portable syringe drivers are commonly used to deliver continuous subcutaneous infusions in palliative care situations. Those in current use are not without problems and serious adverse events have occasionally been reported, mainly resulting from confusion between models. The MP Daily syringe driver addresses some of these issues while remaining small, lightweight and inexpensive, with a long battery life and fitting into the pocket of a shirt of pyjama jacket. Improvements over current models include an on/off button, the absence of facilities to set a zero rate or change the rate once the syringe driver is running, and the absence of a boost button. In addition, there are improved alarms, a message display system and a configuration menu. Although confusion remains a problem, and the ideal has not yet been reached, the MP Daily goes some considerable way towards reducing risks and opportunities for human error.

  16. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  17. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  18. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  19. Continuously pumping and reactivating gas pump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Call, W.R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped

  20. Continuously pumping and reactivating gas pump

    Science.gov (United States)

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  1. Role of the pump limiter throat-ergodic divertor effect on edge plasma

    International Nuclear Information System (INIS)

    Grosman, A.; Samain, A.; Ghendrih, P.; Capes, H.; Morera, J.P.

    1988-01-01

    A large part of the Tore Supra programme is devoted to plasma edge studies. Two types of such density control apparatus have been implemented, a set of pumps limiters and the ergodic divertor. The goal of the present paper is to investigate the effect of the pump limiter throat on pumping efficiency. We present also the possibilities of the ergodic divertor device to facilitate plasma pumping and power exhaust

  2. Making a difference? Applying Vitellone's Social Science of the Syringe to performance and image enhancing drug injecting.

    Science.gov (United States)

    Hart, Aaron

    2018-04-18

    Vitellone's Social Science of the Syringe investigates epistemologies of injecting drug use. She argues for a methodology that can be simultaneously sensitive to biopolitical power regimes; the trajectories of social stratification; and the resistance, creativity and dignity of human agency. She proposes a methodological focus on the syringe-in-use as an active participant in these dynamics. Harm reduction policy and service provision frameworks have paid little attention to the phenomena of performance and image enhancing drug (PIEDs) injection. One way of assessing the merit of Vitellone's proposal is to use it to investigate these phenomena. I argue that Vitellone's method can be used to articulate a range of significant differences between people who inject PIEDs and other people who inject drugs, and that these differences can inform harm reduction initiatives. When compared to the heroin syringe, the PIED syringe participates in different socio-economic and material contexts, gendered identities, and biopolitical governance regimes. These differences materialise in different rates of syringe sharing and blood-borne virus transmission; and different experiences of needle exchange services. I offer a thought experiment demonstrating how a different syringe might alter the structural dynamics, biopolitical governance, and the agentic choices of people who inject PIEDs. Judging by the productive effects of diffracting Vitellone's analysis through an empirical concern with PIED injecting, I concur with Vitellone's proposition that 'something objective may be gained from an empirical investigation of the syringe-in-use' (p. 33). Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Monitoring programme

    International Nuclear Information System (INIS)

    1994-06-01

    Her Majesty's Inspectorate of Pollution's 1992 report on its programme of monitoring radioactive substances is presented. Site operators' returns are verified and the report provides independent data on the environmental impact of authorized disposal of radioactive wastes. Radiation doses which may have been received by members of the public, fall well below the International Commission for Radiological Protection's (ICRP) recommended annual doses. (UK)

  4. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  5. Pumps in mining

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This article looks at the pump industry as a whole, its historical links with the mining industry, their parallel develop ment, and at the individual manufacturers and pumps, services and auxillary products they have to offer.

  6. The properties of an improvised piston pump for the rapid delivery of intravenous fluids.

    Science.gov (United States)

    Smart, C M; Primrose, C W; Peters, A L; Speirits, E J

    2014-02-01

    To maximise the effect of a small fluid load, it is occasionally desirable to bolus manually with multiple depressions of a large-capacity syringe. This is usually achieved by placing the syringe on the side port of a three-way tap. We modified this technique by placing two-one-way valves in line with the three-way tap, effectively creating a piston pump, the infusion rates via which we compared with those achieved by an inflatable pressure-infuser in a simulated resuscitation. Fluid flow was faster using the piston pump than with the pressure-infuser (mean (SD) time to infuse 2000 ml saline 0.9% via a 16-G cannula 352 (10) s vs 495 (19) s, respectively, p piston pump appears to have potential for both tight control of fluid delivery and major high-volume resuscitation. The lightweight nature of the pump and its lack of reliance on gravity may also make it suitable for the pre-hospital setting. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  7. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  8. Rotary magnetic heat pump

    Science.gov (United States)

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  9. Vertical pump assembly

    International Nuclear Information System (INIS)

    Dohnal, M.; Rosel, J.; Skarka, V.

    1988-01-01

    The mounting is described of the drive assembly of a vertical pump for nuclear power plants in areas with seismic risk. The assembly is attached to the building floor using flexible and damping elements. The design allows producing seismically resistant pumps without major design changes in the existing types of vertical pumps. (E.S.). 1 fig

  10. Trend Analyses of Users of a Syringe Exchange Program in Philadelphia, Pennsylvania: 1999-2014.

    Science.gov (United States)

    Maurer, Laurie A; Bass, Sarah Bauerle; Ye, Du; Benitez, José; Mazzella, Silvana; Krafty, Robert

    2016-12-01

    This study examines trends of injection drug users' (IDUs) use of a Philadelphia, Pennsylvania, syringe exchange program (SEP) from 1999 to 2014, including changes in demographics, drug use, substance abuse treatment, geographic indicators, and SEP use. Prevention Point Philadelphia's SEP registration data were analyzed using linear regression, Pearson's Chi square, and t-tests. Over time new SEP registrants have become younger, more racially diverse, and geographically more concentrated in specific areas of the city, corresponding to urban demographic shifts. The number of new registrants per year has decreased, however syringes exchanged have increased. Gentrification, cultural norms, and changes in risk perception are believed to have contributed to the changes in SEP registration. Demographic changes indicate outreach strategies for IDUs may need adjusting to address unique barriers for younger, more racially diverse users. Implications for SEPs are discussed, including policy and continued ability to address current public health threats.

  11. An electrochemical pumping system for on-chip gradient generation.

    Science.gov (United States)

    Xie, Jun; Miao, Yunan; Shih, Jason; He, Qing; Liu, Jun; Tai, Yu-Chong; Lee, Terry D

    2004-07-01

    Within the context of microfluidic systems, it has been difficult to devise pumping systems that can deliver adequate flow rates at high pressure for applications such as HPLC. An on-chip electrochemical pumping system based on electrolysis that offers certain advantages over designs that utilize electroosmotic driven flow has been fabricated and tested. The pump was fabricated on both silicon and glass substrates using photolithography. The electrolysis electrodes were formed from either platinum or gold, and SU8, an epoxy-based photoresist, was used to form the pump chambers. A glass cover plate and a poly(dimethylsiloxane) (PDMS) gasket were used to seal the chambers. Filling of the chambers was accomplished by using a syringe to inject liquid via filling ports, which were later sealed using a glass cover plate. The current supplied to the electrodes controlled the rate of gas formation and, thus, the resulting fluid flow rate. At low backpressures, flow rates >1 microL/min have been demonstrated using polymer electrospray nozzle, we have confirmed the successful generation of a solvent gradient via a mass spectrometer.

  12. Stability of busulfan solutions in polypropylene syringes and infusion bags as determined with an original assay.

    Science.gov (United States)

    Guichard, Nicolas; Bonnabry, Pascal; Rudaz, Serge; Fleury-Souverain, Sandrine

    2017-11-15

    The stability of busulfan solution in 0.9% sodium chloride and stored in polypropylene syringes or infusion bags was evaluated. Busulfan solutions (0.54 mg/mL) were prepared and transferred to 50-mL polypropylene syringes and 100- and 500-mL polypropylene infusion bags and stored at 2-8 and 23-27 °C. Chemical stability was measured using a stability-indicating, ultrahigh performance liquid chromatography coupled to mass spectrometry method. The stability of busulfan was assessed by measuring the percentage of the initial concentration remaining at the end of each time point of analysis. The initial busulfan concentration was defined as 100%. Stability was defined as retention of at least 90% of the initial busulfan concentration. A visual inspection of the samples for particulate matter, clarity, and color without instrumentation of magnification was conducted at each time point of analysis. The visual inspection demonstrated no influence of the storage container when busulfan infusions diluted in 0.9% sodium chloride injection were stored at 23-27 °C. No color change or precipitate was observed at this temperature; however, a rapid decrease of the busulfan content in all containers stored at room temperature was observed. Busulfan in syringes was chemically stable for 12 hours, while busulfan in infusion bags (100 and 500 mL) was stable only for 3 hours at 23-27 °C. Busulfan 0.54-mg/mL solution in 0.9% sodium chloride injection was physically and chemically stable for 30 hours when stored in 50-mL polypropylene syringes at 2-8 °C and protected from light. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  13. Syringe needle skull penetration reduces brain injuries and secondary inflammation following intracerebral neural stem cell transplantation

    OpenAIRE

    Gao, Mou; Dong, Qin; Zhang, Hongtian; Yang, Yang; Zhu, Jianwei; Yang, Zhijun; Xu, Minhui; Xu, Ruxiang

    2017-01-01

    Intracerebral neural stem cell (NSC) transplantation is beneficial for delivering stem cell grafts effectively, however, this approach may subsequently result in brain injury and secondary inflammation. To reduce the risk of promoting brain injury and secondary inflammation, two methods were compared in the present study. Murine skulls were penetrated using a drill on the left side and a syringe needle on the right. Mice were randomly divided into three groups (n=84/group): Group A, receiving...

  14. Drugs given by a syringe driver: a prospective multicentre survey of palliative care services in the UK.

    Science.gov (United States)

    Wilcock, Andrew; Jacob, Jayin K; Charlesworth, Sarah; Harris, Elayne; Gibbs, Margaret; Allsop, Helen

    2006-10-01

    The use of a syringe driver to administer drugs by continuous subcutaneous infusion is common practice in the UK. Over time, drug combinations used in a syringe driver are likely to change and the aim of this survey was to obtain a more recent snapshot of practice. On four separate days, at two-week intervals, a questionnaire was completed for every syringe driver in use by 15 palliative care services. Of 336 syringe drivers, the majority contained either two or three drugs, but one-fifth contained only one drug. The median (range) volume of the infusions was 15 (9.5-48) mL, and duration of infusion was generally 24 hours. Only one combination was reported as visually incompatible, and there were 13 site reactions (4% of total). Laboratory physical and chemical compatibility data are available for less than half of the most frequently used combinations.

  15. Technology Programme

    Energy Technology Data Exchange (ETDEWEB)

    Batistoni, Paola; De Marco, Francesco; Pieroni, Leonardo [ed.

    2005-07-01

    The technology activities carried out by the Euratom-ENEA Association in the framework of the European Fusion Development Agreement concern the Next Step (International Thermonuclear Experimental Reactor - ITER), the Long-Term Programme (breeder blanket, materials, International Fusion Materials Irradiation Facility - IFMIF), Power Plant Conceptual Studies and Socio-Economic Studies. The Underlying Technology Programme was set up to complement the fusion activities as well to develop technologies with a wider range of interest. The Technology Programme mainly involves staff from the Frascati laboratories of the Fusion Technical and Scientific Unit and from the Brasimone laboratories of the Advanced Physics Technologies Unit. Other ENEA units also provide valuable contributions to the programme. ENEA is heavily engaged in component development/testing and in design and safety activities for the European Fusion Technology Programme. Although the work documented in the following covers a large range of topics that differ considerably because they concern the development of extremely complex systems, the high level of integration and coordination ensures the capability to cover the fusion system as a whole. In 2004 the most significant testing activities concerned the ITER primary beryllium-coated first wall. In the field of high-heat-flux components, an important achievement was the qualification of the process for depositing a copper liner on carbon fibre composite (CFC) hollow tiles. This new process, pre-brazed casting (PBC), allows the hot radial pressing (HRP) joining procedure to be used also for CFC-based armour monoblock divertor components. The PBC and HRP processes are candidates for the construction of the ITER divertor. In the materials field an important milestone was the commissioning of a new facility for chemical vapour infiltration/deposition, used for optimising silicon carbide composite (SiCf/SiC) components. Eight patents were deposited during 2004

  16. Technology Programme

    International Nuclear Information System (INIS)

    Batistoni, Paola; De Marco, Francesco; Pieroni, Leonardo

    2005-01-01

    The technology activities carried out by the Euratom-ENEA Association in the framework of the European Fusion Development Agreement concern the Next Step (International Thermonuclear Experimental Reactor - ITER), the Long-Term Programme (breeder blanket, materials, International Fusion Materials Irradiation Facility - IFMIF), Power Plant Conceptual Studies and Socio-Economic Studies. The Underlying Technology Programme was set up to complement the fusion activities as well to develop technologies with a wider range of interest. The Technology Programme mainly involves staff from the Frascati laboratories of the Fusion Technical and Scientific Unit and from the Brasimone laboratories of the Advanced Physics Technologies Unit. Other ENEA units also provide valuable contributions to the programme. ENEA is heavily engaged in component development/testing and in design and safety activities for the European Fusion Technology Programme. Although the work documented in the following covers a large range of topics that differ considerably because they concern the development of extremely complex systems, the high level of integration and coordination ensures the capability to cover the fusion system as a whole. In 2004 the most significant testing activities concerned the ITER primary beryllium-coated first wall. In the field of high-heat-flux components, an important achievement was the qualification of the process for depositing a copper liner on carbon fibre composite (CFC) hollow tiles. This new process, pre-brazed casting (PBC), allows the hot radial pressing (HRP) joining procedure to be used also for CFC-based armour monoblock divertor components. The PBC and HRP processes are candidates for the construction of the ITER divertor. In the materials field an important milestone was the commissioning of a new facility for chemical vapour infiltration/deposition, used for optimising silicon carbide composite (SiCf/SiC) components. Eight patents were deposited during 2004

  17. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.A.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump

  18. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  19. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  20. Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe

    Directory of Open Access Journals (Sweden)

    T D Yogesh Kumar

    2015-01-01

    Full Text Available Aim: The present study evaluated and compared the pain perception, behavioral response, physiological parameters, and the role of topical anesthetic administration during local anesthetic administration with cartridge syringe and computer controlled local anesthetic delivery system (CCLAD. Design: A randomized controlled crossover study was carried out with 120 children aged 7-11 years. They were randomly divided into Group A: Receiving injection with CCLAD during first visit; Group B: Receiving injection with cartridge syringe during first visit. They were further subdivided into three subgroups based on the topical application used: (a 20% benzocaine; (b pressure with cotton applicator; (c no topical application. Pulse rate and blood pressure were recorded before and during injection procedure. Objective evaluation of disruptive behavior and subjective evaluation of pain were done using face legs activity cry consolability scale and modified facial image scale, respectively. The washout period between the two visits was 1-week. Results: Injections with CCLAD produced significantly lesser pain response, disruptive behavior (P < 0.001, and pulse rate (P < 0.05 when compared to cartridge syringe injections. Application of benzocaine produced lesser pain response and disruptive behavior when compared to the other two subgroups, although the result was not significant. Conclusion: Usage of techniques which enhance behavioral response in children like injections with CCLAD can be considered as a possible step toward achieving a pain-free pediatric dental practice.

  1. Determination of bismuth and cadmium after solid-phase extraction with chromosorb-107 in a syringe

    International Nuclear Information System (INIS)

    Tokman, Nilgun; Akman, Suleyman

    2004-01-01

    The determination of bismuth and cadmium by graphite furnace atomic absorption spectrometry (GFAAS) after solid-phase extraction (SPE) on Chromosorb-107 filled in a syringe was described. To retain the analytes, the sample solution treated with and without ammonium pyrolidine dithiocarbamate (APDC) was drawn into the syringe filled with Chromosorb-107 and discharged back manually. Bismuth and cadmium were quantitatively sorbed at pH ≥ 6 irrespective of whether the analyte was complexed with APDC prior to passing through the Chromosorb-107. Analyte elements sorbed on the resin were quantitatively eluted with 3.0 M of HNO 3 again drawing and discharging the eluent into the syringe and ejected it back. Optimum flow rates of sample or eluent for sorption and elution processes were 20 ml min -1 for drawing and 20 ml min -1 for discharging in all cases. Bismuth and cadmium were analyzed by graphite furnace atomic absorption spectrometry. The elements could be concentrated by drawing and discharging several portions of sample successively but eluting only one time. The validity of the proposed method was checked with standard reference materials (NIST SRM 1515 Apple-Leaves, CWW-TM-E Waste Water and CRM-SW Sea Water). The analyte elements were quantitatively (>95%) recovered from different matrices irrespective of treated samples with APDC. Detection limits (δ) were 0.8 and 1.2 μg l -1 for Bi and Cd, respectively. The method can be characterized with fastness, simplicity, quantitative recovery and high reproducibility

  2. Professional ideologies and the development of syringe exchange: Wales as a case study.

    Science.gov (United States)

    Keene, J M; Stimson, G V

    1997-12-01

    This paper is derived from an evaluative study of HIV prevention programs for drug injectors across Wales. It considers how different professional territories and ideologies, concepts of drug misuse and models of HIV prevention may influence policy development. The research involved monitoring the introduction and development of agency and community based syringe exchange schemes and initiatives taken by community pharmacists. Interviews with staff, managers and administrators, and descriptions of service history, development and delivery inform the discussion. HIV prevention varied in different areas of Wales depending on the particular professional group involved, local ideologies regarding drug use treatment, and the extent to which HIV prevention was seen either as a specialist area of expertise and specific remit of drug workers or a generic health care task. Drug agencies with an abstinence policy rejected syringe exchange; instead, prevention in those areas developed in ad hoc ways as health care workers and pharmacists attempted to develop a community based service. Drug agencies with a pre-existing harm minimisation model easily integrated syringe exchange into their work and played the major part in establishing the service, but there was difficulty in extending it beyond their professional caseloads. As there were disincentives to use treatment agencies, and their catchment areas were limited, these factors influenced effective service provision.

  3. Federal funding for syringe exchange in the US: Explaining a long-term policy failure.

    Science.gov (United States)

    Showalter, David

    2018-05-01

    The United States prohibited federal funding for syringe exchange programs for people who inject drugs nearly continuously from 1988 to 2015, despite growing scientific evidence, diminishing AIDS-related controversy, and tens of thousands of deaths from injection-related AIDS. This study investigates the political and institutional bases of this long-term failure to support lifesaving public policy. This study draws on national, regional, and local media coverage, archival sources, and semi-structured, in-depth interviews with 6 long-time syringe exchange researchers and activists from California. I use case-oriented process tracing methods to explain the persistence and reform of the federal funding ban. Though previous studies focus on the symbolic clash between conservative morality and empirical science, I find that changing demographic and regional inequalities in the effects of the AIDS epidemic and dynamics produced by the federal structure of US government were more important factors in the creation and persistence of the funding ban. The persistence and eventual repeal of the ban on federal funding for syringe exchange was a product of the changing demographic, geographic, and political effects of the AIDS epidemic within the federal structure of US government, rather than a consequence of intractable morality politics. These contextual dynamics continue to shape AIDS and public health policy at all levels of government. Copyright © 2018. Published by Elsevier B.V.

  4. Syringe shape and positioning relative to efficiency volume inside dose calibrators and its role in nuclear medicine quality assurance programs

    International Nuclear Information System (INIS)

    Santos, J.A.M.; Carrasco, M.F.; Lencart, J.; Bastos, A.L.

    2009-01-01

    A careful analysis of geometry and source positioning influence in the activity measurement outcome of a nuclear medicine dose calibrator is presented for 99m Tc. The implementation of a quasi-point source apparent activity curve measurement is proposed for an accurate correction of the activity inside several syringes, and compared with a theoretical geometric efficiency model. Additionally, new geometrical parameters are proposed to test and verify the correct positioning of the syringes as part of acceptance testing and quality control procedures.

  5. Pumps for nuclear facilities

    International Nuclear Information System (INIS)

    1999-01-01

    The guide describes how the Finnish Radiation and Nuclear Safety Authority (STUK) controls pumps and their motors at nuclear power plants and other nuclear facilities. The scope of the control is determined by the Safety Class of the pump in question. The various phases of the control are: (1) review of construction plan, (2) control of manufacturing, and construction inspection, (3) commissioning inspection, and (4) control during operation. STUK controls Safety Class 1, 2 and 3 pumps at nuclear facilities as described in this guide. STUK inspects Class EYT (non-nuclear) pumps separately or in connection with the commissioning inspections of the systems. This guide gives the control procedure and related requirements primarily for centrifugal pumps. However, it is also applied to the control of piston pumps and other pump types not mentioned in this guide

  6. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  7. The development of peer educator-based harm reduction programmes in Northern Vietnam.

    Science.gov (United States)

    Walsh, Nick; Gibbie, Tania M; Higgs, Peter

    2008-03-01

    Injecting drug use remains an important risk factor for transmission in Vietnam, with an estimated 50% of the 290 000 people living with HIV/AIDS reporting injecting drug use as a risk factor. Despite this, effective harm reduction interventions are generally lacking. This paper describes the implementation of peer-based harm reduction programmes in two rural provinces of Vietnam. Peer educators were trained in basic HIV prevention, including harm reduction. After significant preparation work with the Provincial AIDS Committees of Bac Giang and Thanh Hoa and other relevant national, provincial and local authorities, the interventions were commenced. Harm reduction interventions were delivered through outreach as well as on-site. This included needle and syringe distribution and collection. Community advocacy occurred throughout the life of the project. Local authorities and peers believed that while there was a general reduction in stigma and discrimination, legal barriers associated particularly with the carrying of injecting equipment remained. This impacted upon the ability of peer educators to work with their clients. Peer-based delivery of harm reduction intervention is acceptable. Harm reduction interventions, including needle and syringe programmes, are feasible and acceptable in these two rural Vietnamese provinces. Community acceptance and uptake of these interventions is key to successful expansion across the region. Active participation by families of drug users seems crucial. This initiative demonstrates that despite a difficult policy environment, peer-delivered needle and syringe programmes are feasible within a rural Asian environment as long as there is adequate local political and community support.

  8. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  9. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    Science.gov (United States)

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  10. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  11. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-12-31

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  12. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-01-01

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  13. In vitro stability of low-concentration ziconotide alone or in admixtures in intrathecal pumps.

    Science.gov (United States)

    Dupoiron, Denis; Richard, Hélène; Chabert-Desnot, Vincent; Devys, Catherine; Leynia, Pierre; Boisdron-Celle, Michèle

    2014-07-01

    Ziconotide is often administered in combination with other analgesics via an intrathecal pump. Studies have established that ziconotide is stable when delivered alone in high concentrations. No stability data are available, however, for ziconotide given in low concentrations and/or with other analgesics as usually occurs in clinical oncology practice. The objective of this study was to assess the in vitro stability of ziconotide alone and combined with other analgesics in intrathecal pumps at 37 °C, as well as in syringes at 5 °C, to evaluate conditions for storing and transporting preparations. Various ziconotide concentrations (0.1, 0.25, 0.5, and 0.75 μg/mL) were combined with an admixture of ropivacaine (7.5 mg/mL), morphine (7.5 mg/mL), and clonidine (15 μg/mL) in 20-mL intrathecal pumps at 37 °C and in syringes at 5 °C. Solutions of ziconotide alone in concentrations of 0.25, 0.5, 0.75, and 1 μg/mL were introduced into pumps at 37 °C and syringes at 5 °C. Assays were performed using ultra high pressure liquid chromatography. In admixtures, mean ziconotide concentrations decreased linearly to 53.4% (± 3.33%) of baseline after 35 days. When ziconotide was introduced alone in pumps at 37 °C, the residual concentration on day 31 was 35.54% (± 0.04%) with 0.25 μg/mL, 39.37% (± 0.15%) with 0.5 μg/mL, and 44.49% (± 0.18%) with 1 μg/mL. Ziconotide alone or combined with the other analgesics was stable in syringes stored at 5 °C. The preparations complied with the prescriptions, with a mean error of less than 10%, except with the lowest ziconotide concentration (0.1 μg/mL). At the low ziconotide concentrations studied, the degradation of ziconotide admixed with other drugs was linear and only weakly influenced by the baseline concentration. Linear regression with intrapolation to 30 days showed that the degradation of ziconotide admixed with other drugs was consistent with previously published data. © 2014 International Neuromodulation Society.

  14. Effect of a syringe aspiration technique versus a mechanical suction technique and use of N-butylscopolammonium bromide on the quantity and quality of bronchoalveolar lavage fluid samples obtained from horses with the summer pasture endophenotype of equine asthma.

    Science.gov (United States)

    Bowser, Jacquelyn E; Costa, Lais R R; Rodil, Alba U; Lopp, Christine T; Johnson, Melanie E; Wills, Robert W; Swiderski, Cyprianna E

    2018-03-01

    OBJECTIVE To evaluate the effect of 2 bronchoalveolar lavage (BAL) sampling techniques and the use of N-butylscopolammonium bromide (NBB) on the quantity and quality of BAL fluid (BALF) samples obtained from horses with the summer pasture endophenotype of equine asthma. ANIMALS 8 horses with the summer pasture endophenotype of equine asthma. PROCEDURES BAL was performed bilaterally (right and left lung sites) with a flexible videoendoscope passed through the left or right nasal passage. During lavage of the first lung site, a BALF sample was collected by means of either gentle syringe aspiration or mechanical suction with a pressure-regulated wall-mounted suction pump. The endoscope was then maneuvered into the contralateral lung site, and lavage was performed with the alternate fluid retrieval technique. For each horse, BAL was performed bilaterally once with and once without premedication with NBB (21-day interval). The BALF samples retrieved were evaluated for volume, total cell count, differential cell count, RBC count, and total protein concentration. RESULTS Use of syringe aspiration significantly increased total BALF volume (mean volume increase, 40 mL [approx 7.5% yield]) and decreased total RBC count (mean decrease, 142 cells/μL), compared with use of mechanical suction. The BALF nucleated cell count and differential cell count did not differ between BAL procedures. Use of NBB had no effect on BALF retrieval. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that retrieval of BALF by syringe aspiration may increase yield and reduce barotrauma in horses at increased risk of bronchoconstriction and bronchiolar collapse. Further studies to determine the usefulness of NBB and other bronchodilators during BAL procedures in horses are warranted.

  15. Investigating Liquid Leak from Pre-Filled Syringes upon Needle Shield Removal: Effect of Air Bubble Pressure.

    Science.gov (United States)

    Chan, Edwin; Maa, Yuh-Fun; Overcashier, David; Hsu, Chung C

    2011-01-01

    This study is to investigate the effect of headspace air pressure in pre-filled syringes on liquid leak (dripping) from the syringe needle upon needle shield removal. Drip tests to measure drip quantity were performed on syringes manually filled with 0.5 or 1.0 mL of various aqueous solutions. Parameters assessed included temperature (filling and test), bulk storage conditions (tank pressure and the type of the pressurized gas), solution composition (pure water, 0.9% sodium chloride, and a monoclonal antibody formulation), and testing procedures. A headspace pressure analyzer was used to verify the drip test method. Results suggested that leakage is indeed caused by headspace pressure increase, and the temperature effect (ideal gas expansion) is a major, but not the only, factor. The dissolved gases in the liquid bulk prior to or during filling may contribute to leakage, as these gases could be released into the headspace due to solubility changes (in response to test temperature and pressure conditions) and cause pressure increase. Needle shield removal procedures were found to cause dripping, but liquid composition played little role. Overall, paying attention to the processing history (pressure and temperature) of the liquid bulk is the key to minimize leakage. The headspace pressure could be reduced by decreasing liquid bulk storage pressure, filling at a higher temperature, or employing lower solubility gas (e.g., helium) for bulk transfer and storage. Leakage could also be mitigated by simply holding the syringe needle pointing upward during needle shield removal. Substantial advances in pre-filled syringe technology development, particularly in syringe filling accuracy, have been made. However, there are factors, as subtle as how the needle shield (or tip cap) is removed, that may affect dosing accuracy. We recently found that upon removal of the tip cap from a syringe held vertically with needle pointed downwards, a small amount of solution, up to 3-4% of

  16. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Phillip M. Paul

    2000-01-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  17. Electrokinetic pumps and actuators

    Energy Technology Data Exchange (ETDEWEB)

    Phillip M. Paul

    2000-03-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps.

  18. Understanding Infusion Pumps.

    Science.gov (United States)

    Mandel, Jeff E

    2018-04-01

    Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.

  19. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  20. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  1. Investigation into the pumping characteristics of ITER cryopumps

    International Nuclear Information System (INIS)

    Day, C.; Mack, A.

    1998-01-01

    Within the framework of the European fusion technology programme, a cryopump system for ITER is being developed. It is based on combined sorption and condensation of gases at SK-surfaces, which are coated with activated charcoal. For verification of the design conditions an experimental programme has been launched. The tested cryopanels followed a quilted design, which is currently being discussed for its use in ITER. According to the composition range of the ITER exhaust gas in the various operation modes foreseen, pure gases (protium, deuterium, helium and neon) and gas mixtures (pseudobinaries of a D 2 -based mixture and one noble gas out of helium, neon or argon) were investigated. Quantitative measurements of pumping speed and equilibrium pressures at zero flow conditions were performed as a function of gas load; relative pumping probabilities were also derived. It is revealed that protium is pumped by sorption whereas neon is pumped by sublimation and deuterium is subjected to both mechanisms. The results demonstrate that the required pump ultimate pressure can be achieved. It is further shown that for the gases investigated the pumping characteristics will not be a limiting factor; the ITER requirements are well achieved. The saturation capacity will not be reached, except if pure helium is pumped. (orig.)

  2. Thermomechanical piston pump development

    Science.gov (United States)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  3. Pumps for nuclear industry

    International Nuclear Information System (INIS)

    Tanguy, L.

    1978-01-01

    In order to meet the requirements of nuclear industry for the transfer of corrosive, toxic, humidity sensitive or very pure gases, different types of pumps were developped and commercialized. Their main characteristics are to prevent pollution of the transfered fluid by avoiding any contact between this fluid and the lubricated parts of the machine, and to prevent a contamination of the atmosphere or of the fluid by a total tightness. Patellar pumps have been particularly developped because the metallic bellows are quite reliable and resistant in this configuration. Two types are described: patellar pumps without friction and barrel pumps whose pistons are provided with rings sliding in the cylinders without lubrication [fr

  4. Pump safety device

    International Nuclear Information System (INIS)

    Timmermans, Francis; Vandervorst, Jean.

    1981-01-01

    Safety device for longitudinally leak proofing the shaft of a pump in the event of the fracture of the dynamic seal separating the pump fluid high pressure chamber from the low pressure chamber. It is designed for fitting to the primary pumps of nuclear reactors. It includes a hollow cyclindrical piston located coaxially around the pump shaft and normally housed in a chamber provided for this purpose in the fixed housing of the dynamic seal, and means for moving this piston coaxially so as to compress a safety O ring between the shaft and the piston in the event of the dynamic seal failing [fr

  5. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  6. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1995-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  7. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  8. ISOLDE PROGRAMME

    CERN Multimedia

    Fedosseev, V; Herfurth, F; Scheidenberger, C; Geppert, C; Gorges, C; Ratajczyk, T; Wiederhold, J C; Vogel, S; Munch, M K; Nieminen, P; Pakarinen, J J A; Lecesne, N; Bouzomita, H; Grinyer, J; Marques moreno, F M; Parlog, M; Blank, B A; Pedroza, J; Ghetta, V; Lozeva, R; Zacarias, S M; Guillemaud mueller, D S; Cottereau, E; Cheikh mhamed, M; Tusseau nenez, S; Tungate, G; Walker, P M; Smith, A G; Fitzpatrick, C; Dominik, W M; Karny, M; Ciemny, A A; Nyman, G H; Thies, R M A; Lindberg, S K G; Langouche, G F; Velten, P; Araujo escalona, V I; Boudreau, M; Domnanich, K A; Richter, D; Lutter, R J; Javaji, A; Engel, R Y; Wiehr, S; Nacher gonzalez, E; Jungclaus, A; Ribeiro jimenez, G; Marroquin alonso, I; Cal gonzalez, J; Paziy, V; Salsac, M; Murphy, C; Podolyak, Z F; Bajoga, A D; Butler, P; Pritchard, A; Colosimo, S J; Steer, A N; Fox, S P; Wadsworth, B A; Truesdale, V L; Al monthery, M; Bracco, A; Guttormsen, M S; Badea, M N; Calinescu, S; Ujeniuc, S; Cederkall, J A; Zemlyanoy, S; Donets, E D; Golovkov, M; Schweitzer, D K; Vranicar, A; Harrichunder, S; Ncube, M; Nannini, A; Strisovska, J; Wolf, E; Gerten, R F; Lehnert, J; Rainovski, G I; Pospisil, S; Datta pramanik, U; Benzoni, G; Fedorov, D; Maier, F M; Bonanni, A; Pfeiffer, B; Griesel, T; Wehner, L W; Mikkelsen, M; Recchia, F; Lenzi, S M; Smith, J F; Kelly, C M; Acosta sanchez, L A; Chavez lomeli, E R; De melo bandeira tavares, P M; Vieira, J M; Martins da silva, M A; Lima lopes, A M; Lopes leal, T J; Mader, J; Kessler, P; Laurent, B G; Schweikhard, L C; Marx, G H; Kulczycka, E; Komorowska, M; Da silva, M F; Goncalves marques, C P; Baptista peres, M A; Welander, J E; Reiter, P; Miller, C; Martin sanchez-cano, D; Wiens, A; Blazhev, A A; Braun, N; Cappellazzo, M V; Birkenbach, B; Gerst, R; Dannhoff, M F; Sithole, M J; Bilgier, B; Nardelli, S; Araujo mendes, C M; Agramunt ros, J; Valencia marin, E; Pantea, E; Hessberger, F P; Leduc, A J; Mitsuoka, S; Carbonari, A W; Buchegger, F J; Garzon camacho, A; Dapo, H; Papka, P; Stachura, M K; Stora, T; Marsh, B A; Thiboud, J A; Heylen, H; Antalic, S; Stahl, C; Bauer, C; Thurauf, M; Maass, B; Sturm, S; Boehm, C; Wolf, N R; Ways, M; Steinsberger, T P; Riisager, K; Ruotsalainen, P A; Bastin, B; Duval, F T; Penessot, G; Flechard, X D; Desrues, P; Giovinazzo, J; Kurtukian nieto, T; Ascher, P E L; Roccia, S; Matea, I; Croizet, H A G; Bonnin, C M; Morfouace, P; Smith, A J; Guin, R; Banerjee, D; Gunnlaugsson, H P; Ohtsubo, T; Zhukov, M V; Tengborn, E A; Welker, A; Giannopoulos, E; Dessagne, P; Juscamaita vivanco, Y; Da costa pereira, L M; Hustings, J; Yu, H; Kruecken, R; Nowak, A K; Jankowski, M; Cano ott, D; Galve lahoz, P; Murphy, A S J; Shand, C M; Jones, G D; Herzberg, R; Ikin, P; Revill, J P; Everett, C; Napoli, D R; Scarel, G; Larsen, A; Tornyi, T G; Pascu, S G; Stroe, L; Toma, S; Jansson, K; Dronjak fahlander, M; Krupko, S; Hurst, A M; Veskovic, M; Nikolov, J; Masenda, H; Sibanda, W N; Rocchini, M; Klimo, J; Deicher, M; Wichert, T; Kronenberg, J; Helmke, A; Meliani, Z; Ivanov, V S; Green, B L; Keatings, J M; Kuti, I; Halasz, Z; Henry, M O; Bras de sequeira amaral, V; Espirito santo, F; Da silva, D J; Rosendahl, S; Vianden, R J; Speidel, K; Agarwal, I; Faul, T; Kownacki, J M; Martins correia, J G; Lorenz, K; Costa miranda, S M; Granadeiro costa, A R; Zyabkin, D; Kotthaus, T; Pfeiffer, M; Gironi, L; Jensen, A; Romstedt, F; Constantino silva furtado, I; Heredia cardona, J A; Jordan martin, M D; Montaner piza, A; Zacate, M O; Plewinski, F; Mesli, A; Akakpo, E H; Pichard, A; Hergemoller, F; Neu, W; Fallis starhunter, J P; Voulot, D; Mrazek, J; Ugryumov, V; Savreux, R P; Kojouharov, I M; Kern, R O; Papst, O; Fitting, J; Lauer, M; Kirsebom, O S; Jensen, K L; Jokinen, A; Rahkila, P J; Hager, U D K; Konki, J P; Dubois, M; Orr, N A; Fabian, X; Huikari, J E; Goigoux, T; Magron, C; Zakari, A A; Maietta, M; Bachelet, C E M; Roussiere, B; Li, R; Canavan, R L; Lorfing, C; Foster, R M; Gislason, H P; Shayestehaminzadeh, S; Qi, B; Mukai, M; Watanabe, Y; Willmann, L; Kurcewicz, W; Wimmer, K; Meisel, Z P; Dorvaux, O; Nowacki, F; Koudriavtsev, I; Lievens, P; Delaure, B J P; Neyens, G; Ceruti, S; Bunka, M; Vermeulen, C; Umbricht, C A; De boer, J; Podadera aliseda, I; Alcorta moreno, M; Pesudo fortes, V; Zielinska, M; Korten, W; Wang, C H; Lotay, G J; Mason, P; Rice, S J; Regan, P H; Willenegger, L M; Andreev, A; Yavuzkanat, N; Hass, M; Kumar, V; Valiente dobon, J J; Crespo campo, L; Zamfir, N - V; Deleanu, D; Clisu, C; Jeppesen, H B; Wu, C; Pain, S D; Stracener, D W; Wuosmaa, A H; Szilner, S; Colovic, P; Matousek, V; Venhart, M; Birova, M; Li, X; Stuchbery, A E; Lellep, G M; Chakraborty, S; Leoni, S; Chupp, T; Yilmaz, C; Severin, G; Garcia ramos, J E; Newton, M E; Hadinia, B; Mc glynn, E; Monteiro de sena silvares de carvalho, I; Friedag, P; Figuera, P; Koos, V; Meot, V H; Pauwels, D B; Jancso, A; Srebrny, J; Alves, E J; David bosne, E; Bengtsson, L; Kalkuehler, M; Albers, M; Bharuth-ram, K; Akkus, B; Hemmingsen, L B S; Pedersen, J T; Dos santos redondo, L M; Rubio barroso, B; Algora, A; Kozlov, V; Mavela, D L; Mokhles gerami, A; Keeley, N; Bernardo da silva, E; Unzueta solozabal, I; Schell, J; Szybowicz, M; Yang, X; Plavec, J; Lassen, J; Johnston, K; Coquard, L; Bloch, T P; Bonig, E S; Stegmann, R; Ignatov, A; Paschalis, S; Fernandez martinez, G; Schilling, M; Habermann, T; Von hahn, R; Minaya ramirez, E E; Moore, I D; Wang, Y; Saastamoinen, A J; Grahn, T; Herzan, A; Stolze, S M; Clement, E; Dijon, A; Shornikov, A; Lienard, E; Gibelin, J D; Pain, C; Canchel, G; Simpson, G S; Latrasse, L P; Huang, W; Forest, D H; Billowes, J; Flanagan, K; Strashnov, I; Binnersley, C L; Sanchez poncela, M; Simpson, J; Morrall, P S; Grant, A F; Charisopoulos, S; Lagogiannis, A; Bhattacharya, C; Olafsson, S; Stepaniuk, M; Tornqvist, H T; Heinz, A M; White iv, E R; Courtin, S; Marechal, F; Da silva fenta, A E; De lemos lima, T A; Stryjczyk, M; Dockx, K; Haller, S; Rizzi, M; Reichert, S B; Bonn, J; Thirolf, P G; Garcia rios, A R; Gugliermina, V M; Cubero campos, M A; Sanchez tembleque, V; Benito garcia, J; Senoville, M; Mountford, D J; Gelletly, W; Alharbi, T S T; Wilson, E; Rigby, S V; Andreoiu, C; Paul, E S; Harkness, L J; Judson, D S; Wraith, C; Van esbroeck, K; Wadsworth, R; Cubiss, J G; Harding, R D; Vaintraub, S; Mandal, S K; Scarpa, D; Hoff, P; Syed naeemul, H; Borcea, R; Balabanski, D L; Marginean, R; Rotaru, F; Rudolph, D; Fahlander, C H; Chudoba, V; Kay, B P; Soic, N; Naidoo, D; Veselsky, M; Kliman, J; Raisanen, J A; Dietrich, M; Maung maung than, M M T; Reed, M W; Danchev, M T; Ray, J; Roy, M; Hammen, M; Capponi, L; Veghne csatlos, M M; Fryar, J; Mirzadeh vaghefi, S P; Trindade pereira, A M; De pinho oliveira, G N; Bakenecker, A; Tramm, C; Germic, V; Morel, P A; Kowalczyk, M; Matejska-minda, M; Wolinska-cichocka, M; Ringvall moberg, A; Mantovan, R; Fransen, C H; Radeck, F; Schneiders, D W; Steinbach, T; Vibenholt, J E; Magnussen, M J; Stevnhoved, H M; Comas lijachev, V; Dasenbrock-gammon, N M; Perkowski, J; O'neill, G G; Matveev, Y; Wegner, M; Liu, Z; Perez alvarez, T; Cerato, L; Radchenko, V; Molholt, T E; Tabares giraldo, J A; Srnka, D; Dlouhy, Z; Beck, D; Werner, V R; Homm, I; Eliseev, S; Blaum, K; Probst, M B; Kaiser, C J; Martin, J A; Refsgaard, J; Peura, P J; Greenlees, P T; Auranen, K; Delahaye, P; Traykov, E K; Perez loureiro, D; Mery, A A; Couratin, C; Tsekhanovich, I; Lunney, D; Gaulard, C V; Mottram, A D; Cullen, D M; Das, S K; Van de walle, J; Mazzocchi, C; Jonson, B N G; Woehr, A; Lesher, S R; Zuber, K T; Filippin, L; De witte, H J; Van den bergh, P A M; Raabe, R; Dirkx, D; Parnefjord gustafsson, F O A; Dunlop, R A; Tarasava, K; Gernhaeuser, R A; Weinzierl, W; Berger, C; Wendt, K; Achtzehn, T; Gottwald, T; Schug, M; Rossel, R E; Dominguez reyes, R R; Fraile prieto, L M; Briz monago, J A; Koester, U H; Bunce, M R; Bowry, M D; Nakhostin, M; Shearman, R; Cresswell, J R; Joss, D T; Gredley, A; Groombridge, D; Laird, A M; Aslanoglou, X; Siem, S; Weterings, J A; Renstrom, T; Szpak, B T; Luczkowski, M J; Ghita, D; Bezbakh, A; Soltz, R A; Bollmann, J; Bhattacharya, P; Roy, S; Rahaman, M A; Wlodarski, T; Carvalho soares, J; Barzakh, A; Schertz, F; Froemmgen, N E; Liberati, V; Foy, B E; Baptista barbosa, M; Weinheimer, C P; Zboril, M; Simon, R E; Popescu, L A; Czosnyka, T; Miranda jana, P A; Leimbach, D; Naskrecki, R; Plociennik, W A; Ruchowska, E E; Chiara, C J; Walters, W; Eberth, J H; Thomas, T; Thole, P; Queiser, M T; Lo bianco, G; D'amico, F; Muller, S; Sanchez alarcon, R M; Tain enriquez, J L; Orrigo, S E A; Orlandi, R; Masango, S; Plazaola muguruza, F C; Lepareur, N G; Fiebig, J M; Ceylan, N; Wildner, E; Kowalska, M; Malbrunot, S; Garcia ruiz, R F; Pallada, S; Slezak, M; Roeckl, E; Schrieder, G H; Ilieva, S K; Koenig, K L; Amoretti, M A; Lommen, J M; Fynbo, H O U; Weyer, G O P; Koldste, G T; Madsboll, K; Jensen, J H; Nieminen, A M; Reponen, M; Villari, A; Thomas, J; Saint-laurent, M; Sorlin, O H; Carniol, B; Pereira lopez, J; Grevy, S; Plaisir, C; Marie-jeanne, M J; Georgiev, G P; Etile, A M; Le blanc, F M; Verney, D; Stefan, G I; Assie, M; Suzuki, D; Guillot, J; Vazquez rodriguez, L; Campbell, P; Deacon, A N; Ware, T; Flueras, A; Xie, L; Banerjee, K; Piersa, M; Galaviz redondo, D; Johansson, H T; Schwarz, S; Toysa, A S; Aumont, J; Van duppen, P L E; Atanasov, D; Zadvornaya, A; Renaud, M A; Xu, Z; Garrett, P E; Rapisarda, E; Reber, J A; Mattolat, C F; Raeder, S; Habs, D; Vidal, M; Perez liva, M; Calvo portela, P; Ulla pedrera, F J; Wood, R T; Lalkovski, S; Page, R; Petri, M; Barton, C J; Nichols, A J; Vermeulen, M J; Bloor, D M; Henderson, J; Wilson, G L; De angelis, G; Buerger, A; Modamio hoybjor, V; Klintefjord, M L; Ingeberg, V W; Fornal, B A; Marginean, R; Sava, T; Kusoglu, A; Suvaila, R; Lica, R; Costache, C; Mihai, R; Ionescu, A; Baeck, T M; Hoffman, C R; Sedlak, M; Koskelo, O K; Kyaw myat, K M; Gladnishki, K A; Ganguly, B; Goncalves marques, J; Cardoso, S; Seliverstov, M; Niessen, B D; Gutt, L E; Chapman, R; Spagnoletti, P N; Lopes, C; De oliveira amorim, C; Batista lopes, C M; Araujo, J; Schielke, S J; Daugas, J R; Gaudefroy, L; Chevrier, R; Szunyogh, D M; Napiorkowski, P J; Wrzosek-lipska, K; Wahl, U; Catarino, N; Pereira carvalho alves de sequeira, M; Hess, H E; Holler, A; Bettermann, L; Geibel, K; Taprogge, J; Lewandowski, L T N; Manchado de sola, F; Cakirli mutlu, R B; Das gupta, S; Thulstrup, P W; Heinz, U; Nogwanya, T; Neidherr, D M; Morales lopez, A I; Gumenyuk, O; Peaker, A R; Wakabayashi, Y; Abrahams, K J; Martin montes, E J; Mach, H A; Souza ribeiro junior, I; He, J; Chalil, A; Xing, R; Dos santos augusto, R M; Giles, T J; Dorsival, A; Trujillo hernandez, J S; Kalaninova, Z; Andel, B; Venos, D; Kraemer, J; Saha, S; Neugart, R; Eronen, T O; Kreim, K D; Heck, M K; Goncharov, M; Karthein, J; Julin, R J; Eleon, C; Achouri, N L; Grinyer, G F; Fontbonne, C M; Alfaurt, P; Lynch, K M; Wilkins, S G; Brown, A R; Imai, N; Pomorski, M J; Janiak, L; Nilsson, T; Stroke, H H; Stanja, J; Dangelser, E; Heenen, P; Godefroid, M; Mallion, S N; Gins, W A M; Stegemann, S T; Koszorus, A; Mcnulty, J F; Lin, P; Ohlert, C M; Schwerdtfeger, W; Tengblad, O; Becerril reyes, A D; Perea martinez, A; Martinez perez, M C; Margerin, V; Rudigier, M; Alexander, T D; Patel, Z V; Hammond, N; Wearing, F; Patel, A; Jenkins, D G; Corradi, L; Galtarossa, F; Debernardi, A; Giacoppo, F; Tveten, G M; Malatji, K L; Krolas, W A; Stanoiu, M A; Rickert, E U; Ter-akopian, G; Cline, D; Riihimaeki, I A; Simon, K D; Wagner, F E; Turker, M; Neef, M H; Coombes, B J; Jakubek, J; Vagena, E; Bottoni, S; Nishimura, K; Correia, J; Rodrigues valdrez, C J; Molkanov, P; Adhikari, R; Ostrowski, A N; Hallmann, O; Scheck, M; Wady, P T; Lane, J; Krasznahorkay, A J; Kunne sohler, D; Meaney, A J; Hochschulz, F; Roig, O; Behan, C C; Kargoll, S; Kemnitz, S; Carvalho teixeira, R C; Redondo cubero, A; Tallarida, G; Kaczarowski, R; Finke, F; Linnemann, A; Altenkirch, R; Saed-samii, N; Ansari, S H; Dlamini, W B; Adoons, V N; Ronning, C R; Wiedeking, M; Herlert, A J; Mehl, C V; Judge, S M; Gaertner, D; Divinskyi, S; Karabasov, M O; Zagoraios, G; Boztosun, I; Van zyl, J J; Catherall, R; Lettry, J; Wenander, F J C; Zakoucky, D; Catchen, G L; Noertershaeuser, W; Kroell, T; Leske, J; Shubina, D; Murray, I M; Pancin, J; Delaunay, F; Poincheval, J J L; Audirac, L L; Gerbaux, M T; Aouadi, M; Sole, P G P; Fallot, M P; Onillon, A; Duchemin, C; Formento cavaier, R; Audi, G; Boukhari, A; Lau, C; Martin, J A; Barre, N H; Berry, T A; Procter, T J; Bladen, L K; Axiotis, M; Muto, S; Jeong, S C; Hirayama, Y; Korgul, A B; Minamisono, K; Bingham, C R; Aprahamian, A; Bucher, B M; Severijns, N; Huyse, M L; Ferrer garcia, R; Verlinde, M N S; Romano, N; Maugeri, E A; Klupp, S C; Dehn, M H; Heinke, R M; Naubereit, P; Maira vidal, A; Vedia fernandez, M V; Ibanez garcia, P B; Bruyneel, B J E; Materna, T; Hadynska-klek, K; Al-dahan, N; Alazemi, N; Carroll, R J; Babcock, C; Patronis, N; Eleme, Z; Dhal, A; Sahin, E; Goergen, A; Maj, A; Bednarczyk, P A; Borcea, C; Negoita, F; Suliman, G; Marginean, N M; Sotty, C O; Negret, A L; Nae, S A; Nita, C; Golubev, P I; Knyazev, A; Jost, C U; Petrik, K; Vaeyrynen, S A; Dracoulis, G D; Uher, J; Fernandez dominguez, B; Chakraborty, P; Avigo, R; Falahat, S; Lekovic, F; Dorrer, H J; Mengoni, D; Derkx, X; Angus, L J; Sandhu, K S; Gregor, E; Kelly, N A; Byrne, D J; Haas, H; Lourenco, A A; Sousa pereira, S M; Sousa, J B; De melo mendonca, T M; Tavares de sousa, C; Guerreiro dos santos oliveira custodio, L M; Da rocha rodrigues, P M; Yamaguchi, T; Thompson, P C; Rosenbusch, M; Wienholtz, F; Fischer, P; Iwanicki, J S; Rusek, K M; Hanstorp, D; Vetter, U; Wolak, J M; Park, S H; Warr, N V; Doornenbal, P C; Imig, A; Seidlitz, M; Moschner, K; Vogt, A; Kaya, L; Martel bravo, I; Orduz, A K; Serot, O; Majola, S N; Litvinov, Y; Bommert, M; Hensel, S; Markevich, V; Nishio, K; Ota, S; Matos, I; Zenkevich, A; Picado sandi, E; Forstner, O; Hu, B; Ntshangase, S S; Sanchez-segovia, J

    2002-01-01

    The experiments aim at a broad exploration of the properties of atomic nuclei far away from the region of beta stability. Furthermore, the unique radioactive beams of over 60~elements produced at the on-line isotope separators ISOLDE-2 and ISOLDE-3 are used in a wide programme of atomic, solid state and surface physics. Around 300 scientists are involved in the project, coming from about 70 laboratories. \\\\ \\\\ The electromagnetic isotope separators are connected on-line with their production targets in the extracted 600 MeV proton or 910~MeV Helium-3 beam of the Synchro-Cyclotron. Secondary beams of radioactive isotopes are available at the facility in intensities of 10$^1

  9. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid ''M''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs

  10. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid P

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''P''. The Appendices contains copies of the printouts of these software programs

  11. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-02-14

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''M''. The Appendices contains copies of the printouts of these software programs.

  12. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    2000-01-03

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs.

  13. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid ''L''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describes the software programs for the Programmable Logic Controller and the Data Table Access Module for Pumping Instrumentation and Control skid ''L''. The Appendices contains copies of the printouts of these software programs

  14. Design and development of a manual pump for bolus enteral nutrition.

    Science.gov (United States)

    Romano-García, Judit; Fernández-Morera, Juan Luis

    2018-02-01

    Enteral nutrition (EN) is based on administration of liquid solutions into the gastrointestinal tract using a tube. After identifying unsolved practical difficulties in administration of EN using volume syringes, a new device to overcome such technical difficulties was proposed. Specific technologies (CAD, 3D printing) were used in collaboration with the PRODINTEC Foundation (Gijón, Asturias). Clarke Modet, a law firm specialized in intellectual property, provided legal advice on formulas for legal protection of the invention. The resulting device is a manual pump for infusion of EN to patients that solves previously identified problems and is highly functional and compact. It would allow for comfortable and safe administration of solutions. Integration of a bottle into the device itself and pump dimensions facilitate transport and patient mobility. According to the described configuration, this invention has many advantages over the previously known procedures, such as a simpler administration within the field of intermittent EN, improving the standard nutritional support technique, which in this case is use of volume syringes. This would facilitate the work of caregivers while promoting patient self-care and autonomy. The pump was accredited novelty of design, inventive activity and industrial exploitation potential by the European Patent Office (EPO), to which a patent has been requested. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Making Nasopalatine Blocks Comfortable: A Randomised Prospective Clinical Comparison of Pain Associated with the Injection Using an Insulin Syringe and a Standard Disposable 3 mL Syringe.

    Science.gov (United States)

    Prabhu, Sundararaman; Faizel, Syed; Pahlajani, Vedant; Prabhu, Shweta Jha

    2013-12-01

    This study was conducted to compare and evaluate the pain associated with administration of Nasopalatine blocks using a disposable insulin syringe and the conventional disposable 3 mL syringe. Forty patients requiring intraalveolar extractions of maxillary central incisors were randomly assigned to two groups of 20 patients each; one (Group A) received the nasopalatine block with a standard 3mL syringe and the other (Group B) received the block with an insulin syringe. Patients were asked to rate the pain associated with the injection on a visual analog scale (VAS) and the results were analysed using a Chi Square Test. The mean VAS score for Group A and B was 1.55 and 1 respectively. Chi Square value was calculated to be 8.603 (degree of freedom= 3, P value= 0.0351). There were no differences in the effectiveness of anesthesia between the groups. Pain associated with administration of the nasopalatine blocks may be significantly mitigated by using the Insulin syringe.

  16. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    Mekelle University, Mekelle, Ethiopia (*mul_at@yahoo.com). ABSTRACT. A wind ... balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. ... Keywords: Wind pump, Windmill, Performance testing, Pump efficiency, Pump discharge, ... Unfortunately, in rural places, where the houses are.

  17. [Preference for etanercept pen versus syringe in patients with chronic arthritis. Nurse education workshop].

    Science.gov (United States)

    Garcia-Diaz, Silvia; Girabent-Farrés, Montserrat; Roig-Vilaseca, Daniel; Reina, Delia; Cerdà, Dacia; González, Marina; Torrente-Segarra, Vicenç; Fíguls, Ramon; Corominas, Hèctor

    2013-01-01

    The aims of this study are to evaluate the level of fear of post-injection pain prior to the administration, the difficulty in handling the device, and the level of satisfaction of patients using a pre-filled syringe versus an etanercept pen, as well as to evaluate the usefulness of the training given by nursing staff prior to starting with the pen, and the preferences of patients after using both devices. A prospective study was designed to follow-up a cohort of patients during a 6 months period. The data was collected using questionnaires and analyzed with SPSS 18.00. Rank and McNemar tests were performed. Statistical significance was pre-set at an α level of 0.05. A total of 29 patients were included, of whom 69% female, and with a mean age 52.5±10.9 years. Of these, 48% had rheumatoid arthritis, 28% psoriatic arthritis, 21% ankylosing spondylitis, and 3% undifferentiated spondyloarthropathy. There were no statistically significant differences either with the fear or pain or handling of the device between the syringe and the pen (P=.469; P=.812; P=.169 respectively). At 6 months, 59% of patients referred to being satisfied or very satisfied with the pen. Almost all (93%) found useful or very useful the training given by nursing staff prior to using the pen, and 55% preferred the pen over the pre-filled syringe. The etanercept pen is another subcutaneous device option for patients with chronic arthritis. According to the present study, nursing educational workshops before starting this therapy are recommended. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  18. Emission characteristics of plastic syringes sterilized with ethylene oxide--a controlled study.

    Science.gov (United States)

    Chien, Yeh-Chung; Su, Po-Chi; Lee, Lien-Hsiung; Chen, Chang-Yuh

    2009-11-01

    This study examined the emission characteristics of ethylene oxide (EO)-sterilized syringes under various environmental conditions, aiming to develop control strategies to minimize worker exposure. Experiments were performed in a facility in which temperature, relative humidity (RH), and air change rate (ACR) were controlled. Analytical results indicate that the main effects of the four test variables on kinetic parameters were statistically significant (p Plastic content, temperature, RH, and ACR affected EO emissions. ACR is an achievable means of control; however, the aeration area/system should be isolated to ensure adequate ventilation is achieved.

  19. Syringe confiscation as an HIV risk factor: the public health implications of arbitrary policing in Tijuana and Ciudad Juarez, Mexico.

    Science.gov (United States)

    Beletsky, Leo; Lozada, Remedios; Gaines, Tommi; Abramovitz, Daniela; Staines, Hugo; Vera, Alicia; Rangel, Gudelia; Arredondo, Jaime; Strathdee, Steffanie A

    2013-04-01

    Female sex workers who inject drugs (FSW-IDUs) face elevated risk for HIV/STIs and constitute a key population for public health prevention. Through direct and indirect pathways including human rights violations, policing practices like syringe confiscation can compound FSW-IDU health risk and facilitate the spread of disease. We studied correlates of experiencing syringe confiscation among FSW-IDUs in northern Mexico, where formal policy allows for syringes to be available over the counter without a prescription, but police practices are often at odds with the law. FSW-IDUs reporting recent syringe sharing and unprotected sex with clients in Tijuana and Ciudad Juarez were administered surveys and HIV/STI testing. Logistic regression was used to identify correlates of syringe confiscation. Among 624 respondent FSW-IDUs, prevalence of syringe confiscation in the last 6 months was 48%. The following factors were positively associated with syringe confiscation: testing positive for HIV (adjusted odds ratio [aOR] = 2.54, 95% confidence interval [CI] = 1.11-5.80), reporting sexual abuse by police (aOR = 12.76, 95% CI = 6.58-24.72), engaging in groin injection (aOR = 1.84, 95% CI = 1.15-2.93), injecting in public (aOR = 1.64; 95% CI = 1.14-2.36), and obtaining syringes from pharmacies (aOR = 1.54; 95% CI = 1.06-2.23). Higher education level was negatively associated with syringe confiscation (aOR = 0.92, 95% CI = 0.87-0.98) as was frequent injection with clients within the last month (aOR = 0.64, 95% CI = 0.44-0.94). This analysis adds to the body of evidence linking unauthorized law enforcement actions targeting high-risk groups with HIV and other adverse health outcomes. Using a public health lens to conceptualize abuse as a structural risk factor, we advocate for multi-prong prevention, systematic monitoring, and evidence-based intervention response to deleterious police practices.

  20. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  1. Comparison between syringe irrigation and RinsEndo in reduction of Enterococcus faecalis in experimentally infected root canal

    Directory of Open Access Journals (Sweden)

    Sharareh Mousavi Zahed

    2015-05-01

    Full Text Available Background and Aims: To ensure root canal treatment success, endodontic microbiota should be efficiently reduced. Several irrigation devices have been recently introduced with the main objective of improving root canal disinfection.The purpose of this study was to evaluate the rinsing effect of RinsEndo system in reduction of enterococcus faecalis in comparison with conventional hand syringe in infected root canals.   Materials and Methods: 60 extracted single canal anterior teeth were infected with enterococcus faecalis and divided into 3 groups: RinsEndo system, conventional hand syringe and control group. The enterococcus faecalis colonies were counted in each group before and after rinsing. Data were analyzed using Variance and Kruskal Wallis test.   Results: The mean of enterococcus faecalis growth after rinsing was 3.50×103 in group with conventional syring rinsing, 2.04×103 in group with RinsEndo washing and 6.11×103 in control group. Reduction of enterococcus faecalis after rinsing was statistically significant in each group (P<0.001. The amount of reduction in number of colonies with RinsEndo and conventional syringe rinsing was higher in comparison with control group and this difference was significant (P<0.001. RinsEndo rinsing effect was statistically significantly higher in comparison to conventional syringe as well (P<0.001.   Conclusion: Rinsing with RinsEndo system was significantly more efficient in reduction of enterococcus faecalis from root canal in comparison with hand syringe washing.

  2. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous spectral vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition: advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  3. Normetex Pump Alternatives Study

    International Nuclear Information System (INIS)

    Clark, Elliot A.

    2013-01-01

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  4. Circulation pump mounting

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    The suspension is described of nuclear reactor circulating pumps enabling their dilatation with a minimum reverse force consisting of spacing rods supported with one end in the anchor joints and provided with springs and screw joints engaging the circulating pump shoes. The spacing rods are equipped with side vibration dampers anchored in the shaft side wall and on the body of the circulating pump drive body. The negative reverse force F of the spacing rods is given by the relation F=Q/l.y, where Q is the weight of the circulating pump, l is the spatial distance between the shoe joints and anchor joints, and y is the deflection of the circulating pump vertical axis from the mean equilibrium position. The described suspension is advantageous in that that the reverse force for the deflection from the mean equilibrium position is minimal, dynamic behaviour is better, and construction costs are lower compared to suspension design used so far. (J.B.)

  5. Technology programme

    International Nuclear Information System (INIS)

    2007-01-01

    The technology activities carried out by the EURATOM-ENEA Association concern the continuation of the European Fusion Development Agreement (EFDA) as well as the ITER activities coordinated by the ITER International Office and Fusion for Energy. Also included in the activities are design and RD under the Broader Approach Agreement between the EU and Japan. In order to better contribute to the programme a number of consortium agreements among the Associations are being signed. Collaboration with industries in view of their participation in the construction of ITER was further strengthened, mainly in the field of magnet and divertor components. The new European Test Blanket Facility at ENEA Brasimone was completed; the design of the ITER radial neutron camera was optimised and the performance achievable with the in-vessel viewing system was further assessed by experimental trials. Design activities for the JT-60SA magnet and power supply system as well as the design and experimental activities related to the target of the International Fusion Materials Irradiation Facility were continued. Significant work was done to define quality assurance for neutronics analyses. Mockups of the ITER pre-compression ring made in glass fibre epoxy were tested. The activities and results documented in the following illustrate ENEA's efforts to support fusion development

  6. BWR series pump recirculation system

    International Nuclear Information System (INIS)

    Dillmann, C.W.

    1992-01-01

    This patent describes a recirculation system for driving reactor coolant water contained in an annular downcomer defined between a boiling water reactor vessel and a reactor core spaced radially inwardly therefrom. It comprises a plurality of circumferentially spaced second pumps disposed in the downcomer, each including an inlet for receiving from the downcomer a portion of the coolant water as pump inlet flow, and an outlet for discharging the pump inlet flow pressurized in the second pump as pump outlet flow; and means for increasing pressure of the pump inlet flow at the pump inlet including a first pump disposed in series flow with the second pump for first receiving the pump inlet flow from the downcomer and discharging to the second pump inlet flow pressurized in the first pump

  7. High pressure liquid gas pump

    Science.gov (United States)

    Acres, R. L.

    1972-01-01

    Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

  8. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    Science.gov (United States)

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  9. Correlates of lending needles/syringes among HIV-seropositive injection drug users.

    Science.gov (United States)

    Metsch, Lisa R; Pereyra, Margaret; Purcell, David W; Latkin, Carl A; Malow, Robert; Gómez, Cynthia A; Latka, Mary H

    2007-11-01

    Among HIV-positive injection drug users (IDUs), we examined the correlates of lending needles/syringes with HIV-negative and unknown status injection partners. HIV-positive IDUs (N=738) from 4 cities in the United States who reported injection drug use with other IDUs in the past 3 months participated in an audio computer-assisted self-administered interview. Eighteen percent of study participants self-reported having lent their needles to HIV-negative or unknown status injection partners. Multivariate analyses showed that 6 variables were significantly associated with this high-risk injecting practice. Older IDUs, high school graduates, and those reporting more supportive peer norms for safer drug use were less likely to lend needles/syringes. Admission to a hospital for drug treatment in the past 6 months, having injected with >1 person in the past 3 months, and having more psychiatric symptoms were all associated with more risk. These findings underscore the need for a continued prevention focus on HIV-positive IDUs that recognizes the combination of drug use, mental health factors, and social factors that might affect this high-risk injecting practice, which could be associated with HIV and hepatitis C transmission.

  10. A practical guide for nurses in diluent selection for subcutaneous infusion using a syringe driver.

    Science.gov (United States)

    McLeod, Fiona; Flowers, Charne

    2006-12-01

    Appropriate diluent selection in continuous subcutaneous infusion optimises symptom management and client well-being. The responsibility of diluent selection is commonly one of the attending nurse. This paper was developed with the intention of providing nurses with practical instruction for diluent selection when preparing medications for administration subcutaneously using a syringe driver. A literature review was undertaken of published journal databases and published guidelines sites. Recommendations regarding diluent choice were reviewed in two iterations by an expert panel of palliative care nurse clinicians. The principles for diluent selection are presented. They are based primarily on expert opinion level of evidence given a lack of primary research evidence in the area of diluent selection. There is a pressing need for manufacturers' guidance on diluent selection and independent research to establish the impact of diluents on drug and drug combinations when using syringe drivers. Until such time that this evidence is available to guide practice, clinicians need to be trained to inspect solutions and assess the effectiveness of the medication in controlling symptoms. The capacity of this paper to provide practical instruction has been limited by the lack of rigorous evidence available, and indeed, the process of developing this guide identified perhaps more questions than answers available at the present time.

  11. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Logistics management in Universal Immunisation Programme.

    Science.gov (United States)

    Bachani, D; Bansal, R D

    1990-01-01

    The review of the National Immunization Programme of India in 1989 focused attention to the issue of storage and distribution of vaccines. Cold-chain equipment such as walk-in-coolers (WICs), deep freezers, ice-lined refrigerators (ILRs), and vaccine carriers proliferated after the introduction of the universal immunization program (UIP) but the available units fell short of the official targets in 1988, especially ILRs (7500 proposed and 2876 available) and vaccine carriers (250,000 proposed and 35,500 available). Some states had over 6 months of supplies of vaccines whose management posed problems of losing potency: oral polio virus (OPV) potency was acceptable in 63% of stock in 1988. Syringes, needles, stoves, pressure-cooker sterilizers, dial thermometers, and refrigerator repair kits were in short supply especially at the primary health care (PHC) level. Only 1/3 of subcenters had sterilizers and 58% had vaccines carriers. Logistics management on the state level required provision of vaccines based on previous use and eligible population with even distribution throughout the year. On the district level WICs were needed for every district with 1.5 million inhabitants. Recording of vaccine requirement, utilization, and storage would aid target allocations and avoid wastage. On the institutional and PHC level an ILR and a transporting vehicle was needed. The number of women and children eligible for immunization had to be calculated based on real population figures. Cold-chain capacity of 30,000-40,000 vials was required for a district as well as about 500 reusable syringes and needles a year along with vaccination cards exceeding the number of women and children by 10% for recordkeeping at the PHC center.

  13. The Association Between Law Enforcement Encounters and Syringe Sharing Among IDUs on Skid Row: A Mixed Methods Analysis

    Science.gov (United States)

    Simon-Freeman, Rebecca; Bluthenthal, Ricky N.

    2013-01-01

    The legal environment is one factor that influences injection drug users' (IDUs) risk for HIV and other bloodborne pathogens such as hepatitis C virus (HCV). We examined the association between law enforcement encounters (i.e., arrests and citations) and receptive syringe sharing among IDUs in the context of an intensified policing effort. We conducted a mixed methods analysis of 30 qualitative and 187 quantitative interviews with IDUs accessing services at a Los Angeles, CA syringe exchange program from 2008 to 2009. Qualitative findings illustrate concerns related to visibility, drug withdrawal, and previous history of arrest/incarceration. In quantitative analysis, the number of citations received, current homelessness, and perceiving that being arrested would be a “big problem” were independently associated with recent syringe sharing. Findings illustrate some of the unintended public health consequences associated with intensified street-level policing, including risk for HIV and HCV transmission. PMID:23620243

  14. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  15. Integrating multiple programme and policy approaches to hepatitis C prevention and care for injection drug users: a comprehensive approach.

    Science.gov (United States)

    Birkhead, Guthrie S; Klein, Susan J; Candelas, Alma R; O'Connell, Daniel A; Rothman, Jeffrey R; Feldman, Ira S; Tsui, Dennis S; Cotroneo, Richard A; Flanigan, Colleen A

    2007-10-01

    New York State is home to an estimated 230,000 individuals chronically infected with hepatitis C virus (HCV) and roughly 171,500 active injection drug users (IDUs). HCV/HIV co-infection is common and models of service delivery that effectively meet IDUs' needs are required. A HCV strategic plan has stressed integration. HCV prevention and care are integrated within health and human service settings, including HIV/AIDS organisations and drug treatment programmes. Other measures that support comprehensive HCV services for IDUs include reimbursement, clinical guidelines, training and HCV prevention education. Community and provider collaborations inform programme and policy development. IDUs access 5 million syringes annually through harm reduction/syringe exchange programmes (SEPs) and a statewide syringe access programme. Declines in HCV prevalence amongst IDUs in New York City coincided with improved syringe availability. New models of care successfully link IDUs at SEPs and in drug treatment to health care. Over 7000 Medicaid recipients with HCV/HIV co-infection had health care encounters related to their HCV in a 12-month period and 10,547 claims for HCV-related medications were paid. The success rate of transitional case management referrals to drug treatment is over 90%. Training and clinical guidelines promote provider knowledge about HCV and contribute to quality HCV care for IDUs. Chart reviews of 2570 patients with HIV in 2004 documented HCV status 97.4% of the time, overall, in various settings. New HCV surveillance systems are operational. Despite this progress, significant challenges remain. A comprehensive, public health approach, using multiple strategies across systems and mobilizing multiple sectors, can enhance IDUs access to HCV prevention and care. A holisitic approach with integrated services, including for HCV-HIV co-infected IDUs is needed. Leadership, collaboration and resources are essential.

  16. Social network-related risk factors for bloodborne virus infections among injection drug users receiving syringes through secondary exchange.

    Science.gov (United States)

    De, Prithwish; Cox, Joseph; Boivin, Jean-François; Platt, Robert W; Jolly, Ann M

    2008-01-01

    Secondary syringe exchange (SSE) refers to the exchange of sterile syringes between injection drug users (IDUs). To date there has been limited examination of SSE in relation to the social networks of IDUs. This study aimed to identify characteristics of drug injecting networks associated with the receipt of syringes through SSE. Active IDUs were recruited from syringe exchange and methadone treatment programs in Montreal, Canada, between April 2004 and January 2005. Information on each participant and on their drug-injecting networks was elicited using a structured, interviewer-administered questionnaire. Subjects' network characteristics were examined in relation to SSE using regression models with generalized estimating equations. Of 218 participants, 126 were SSE recipients with 186 IDUs in their injecting networks. The 92 non-recipients reported 188 network IDUs. Networks of SSE recipients and non-recipients were similar with regard to network size and demographics of network members. In multivariate analyses adjusted for age and gender, SSE recipients were more likely than non-recipients to self-report being HIV-positive (OR=3.56 [1.54-8.23]); require or provide help with injecting (OR=3.74 [2.01-6.95]); have a social network member who is a sexual partner (OR=1.90 [1.11-3.24]), who currently attends a syringe exchange or methadone program (OR=2.33 [1.16-4.70]), injects daily (OR=1.77 [1.11-2.84]), and shares syringes with the subject (OR=2.24 [1.13-4.46]). SSE is associated with several injection-related risk factors that could be used to help focus public health interventions for risk reduction. Since SSE offers an opportunity for the dissemination of important prevention messages, SSE-based networks should be used to improve public health interventions. This approach can optimize the benefits of SSE while minimizing the potential risks associated with the practice of secondary exchange.

  17. Syringe shape and positioning relative to efficiency volume inside dose calibrators and its role in nuclear medicine quality assurance programs

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J.A.M. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Centro de Investigacao, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal)], E-mail: a.miranda@portugalmail.pt; Carrasco, M.F. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Centro de Investigacao, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Lencart, J. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Bastos, A.L. [Servico de Medicina Nuclear, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal)

    2009-06-15

    A careful analysis of geometry and source positioning influence in the activity measurement outcome of a nuclear medicine dose calibrator is presented for {sup 99m}Tc. The implementation of a quasi-point source apparent activity curve measurement is proposed for an accurate correction of the activity inside several syringes, and compared with a theoretical geometric efficiency model. Additionally, new geometrical parameters are proposed to test and verify the correct positioning of the syringes as part of acceptance testing and quality control procedures.

  18. The acoustic detection of cavitation in pumps

    International Nuclear Information System (INIS)

    Macleod, I.D.; Gray, B.S.; Taylor, C.G.

    1978-01-01

    A programme was initiated to develop a reliable technique for detecting the onset of acoustic noise from cavitation in a pump and to relate this to cavitation inception data, since significant noise from collapse of vapour bubbles arising from such cavitation would reduce the sensitivity of a noise detection system for boiling of sodium in fast breeder reactors. Factors affecting the detection of cavitation are discussed. The instrumentation and techniques of frequency analysis and pulse detection are described. Two examples are then given of the application of acoustic detection techniques under controlled conditions. It is concluded that acoustic detection can be a reliable method for detecting inception of cavitation in a pump and the required conditions are stated. (U.K.)

  19. Planning and management support for NPP personnel SAT-based training programmes

    International Nuclear Information System (INIS)

    Ziakova, M.

    1998-01-01

    Planning and management support for NPP personnel SAT-based training programmes is described for the following job positions: reactor operator; turbine operator; reactor maintenance worker; pump maintenance worker; chemistry foreman; health physics foreman; electric maintenance worker

  20. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  1. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  2. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  3. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  4. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  5. Mechanical vaccum pumps

    CERN Document Server

    Chew, A D

    2007-01-01

    This presentation gives an overview of the technology of contemporary primary and secondary mechanical vacuum pumps. For reference a brief history of vacuum and a summary of important and basic vacuum concepts are first presented.

  6. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.; Abdelghany, Mohamed A.; Elsayed, Mohannad Yomn; Elshurafa, Amro M; Salama, Khaled N.

    2014-01-01

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  7. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  8. GAS METERING PUMP

    Science.gov (United States)

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  9. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  10. Types of Breast Pumps

    Science.gov (United States)

    ... called a bicycle horn pump, consists of a hollow rubber ball attached to a breast-shield. Some ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  11. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  12. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  13. Resorption heat pump

    International Nuclear Information System (INIS)

    Vasiliev, L.L.; Mishkinis, D.A.; Antukh, A.A.; Kulakov, A.G.; Vasiliev, L.L.

    2004-01-01

    Resorption processes are based on at least two solid-sorption reactors application. The most favorable situation for the resorption heat pumps is the case, when the presence of a liquid phase is impossible. From simple case--two reactors with two salts to complicated system with two salts + active carbon fiber (fabric) and two branch of the heat pump acting out of phase to produce heat and cold simultaneously, this is the topic of this research program

  14. Portable photovoltaic irrigation pumps

    Energy Technology Data Exchange (ETDEWEB)

    Furber, J. D.

    1980-07-01

    Experiences in developing a solar-powered irrigation pump to meet the needs of poor farmers in developing nations are summarized. The design which evolved is small and portable, employing a high-efficiency electric pump, powered by photovoltaic panels. Particular emphasis is placed on how the system works, and on early field problems experienced with the first prototypes. The resolution of these problems and the performance of actual systems in various countries is presented and user responses are noted.

  15. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.

    1984-05-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  16. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.; California Univ., Los Angeles

    1984-01-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6 MW of auxiliary neutral beam heating. Experiments have also been performed with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scrape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a regime may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this 'Z-mode' of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described. (orig.)

  17. Moving beyond non-engagement on regulated needle-syringe exchange programs in Australian prisons

    Directory of Open Access Journals (Sweden)

    Levy Michael

    2009-05-01

    Full Text Available Abstract Background Australia is at a fork in the road with the possibility of a needle-syringe exchange program (NSP to be introduced at the new prison in the ACT. However, the current situation is characterised by non-engagement from major stakeholders. We explore why informed discussion will not be enough to convince prison officers, policy makers and the wider community of the benefits of prison-based NSPs. Other methods of engagement and communication will be proposed – in that may provide avenues for "breakthrough". Methods A review of the literature on needle-syringe exchanges and harm reduction strategies within the context of prisons and prisoner health was conducted. Literature on strategies to change attitudes and move beyond intractable situations was also consulted. In addition, one author, DM, conducted a two-hour interview with an ex-prison officer. Results No studies were found which investigated the potential efficacy of interventions to modify attitudes or behaviours in the specific context of introducing an NSP into a prison. Nonetheless, several theories were identified which may explain the failure of informed discussion alone to create change in this situation and may therefore lead to suggestions for engagement and communication to move towards a resolution Discussion Cognitive-behavioural therapy highlights the importance of individual cognitions and how they shape behaviours in any change campaign. Social identity theory emphasizes changes to social processes that may open the prison officer workforce to change. Peace studies also suggests socialization strategies such as observing an established and effective prison-based needle-syringe exchange. Social marketing provides suggestions on how to sell an exchange to ensuring the benefits are framed to outweigh the costs. Conclusion Psychology, peace studies and social marketing all agree people's views must be carefully collected and analysed if people are going to be

  18. Investigation of Two Prototypes of Novel Noncontact Technologies for Automated Real-Time Capture of Incremental Drug Administration Data From Syringes.

    Science.gov (United States)

    Eagle, Benjamin; Williams, David J; Dingley, John

    2017-08-01

    An ideal electronic anesthesia recording system would be capable of not only recording physiological data but also injectable drug doses given, including those given incrementally from one syringe, without recourse to manual data entry. We compared 2 prototype devices which wirelessly recognized individual syringes and measured changes in their plunger positions via 2 different optical noncontact means, allowing calculation of incremental drug doses given. Both devices incorporated a radio-frequency identification reader, which wirelessly read a unique code from a radio-frequency identification tag within syringe drug labels. A custom-designed cradle oriented any inserted 1-mL to 20-mL syringe in a repeatable position. The "laser" device had a moving laser beam broken by the end of the syringe plunger. The infrared (IR) device measured time of travel of IR light from a sender to a syringe plunger and back to a receiver. Both devices could therefore determine the drug and volume administered since the previous occasion when any syringe had been used. For each syringe size of 1, 2, 5, 10, and 20 mL, 121 plunger-length measurements were made over their full range, with each machine against a reference method of water filling and weighing using a randomized de Bruijn sequence. For every syringe size, the laser device showed greater accuracy and precision, lower bias, and narrower limits of agreement (95% confidence intervals = bias ± 1.96 SD) than the IR device when compared to the reference method. For all syringe sizes, the range of bias was -0.05 to 0.32 mL for the laser and -2.42 to 1.38 mL for the IR. Lin concordance correlation coefficient values for the IR versus reference methods ranged from 0.6259 to 0.9255, with the lowest coefficients seen in syringes with the shortest distance of plunger travel (2 and 5 mL), while in laser versus reference comparisons, these coefficients were similar (0.9641-0.9981) over all syringe lengths. Both devices measured syringe

  19. Energy efficiency in pumps

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Durmus; Yagmur, E. Alptekin [TUBITAK-MRC, P.O. Box 21, 41470 Gebze, Kocaeli (Turkey); Yigit, K. Suleyman; Eren, A. Salih; Celik, Cenk [Engineering Faculty, Kocaeli University, Kocaeli (Turkey); Kilic, Fatma Canka [Department of Air Conditioning and Refrigeration, Kocaeli University, Kullar, Kocaeli (Turkey)

    2008-06-15

    In this paper, ''energy efficiency'' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems. (author)

  20. Energy efficiency in pumps

    International Nuclear Information System (INIS)

    Kaya, Durmus; Yagmur, E. Alptekin; Yigit, K. Suleyman; Kilic, Fatma Canka; Eren, A. Salih; Celik, Cenk

    2008-01-01

    In this paper, 'energy efficiency' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems

  1. National programme: Finland

    International Nuclear Information System (INIS)

    Forsten, J.

    1986-01-01

    Finland's programmes in the field of reactor pressure components are presented in this paper. The following information on each of these programmes is given: the brief description of the programme; the programme's schedule and duration; the name of the project manager

  2. Pump trials for charged liquids

    International Nuclear Information System (INIS)

    Moroni, J.C.; Niver, A.

    1964-01-01

    The pumps intended for the circulation of charged and radioactive liquids have particular qualities. The choice of such a pump has called for endurance tests with various types of equipment: a Goodyear volumetric screw pumps, and RICHIER, Klein and SCHABAVER centrifugal pumps. The latter, fitted with a special oakum, gave the best results. (authors) [fr

  3. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the

  4. The Computer in a Programmable Implantable Medication System (PIMS)

    OpenAIRE

    Sanders, K. H.; Radford, W. E.

    1982-01-01

    The Programmable Implantable Medication System (PIMS) developed at APL can be used in the treatment of diabetes, reproductive hormone dysfunction, hypertension, cancer, chronic pain, thrombosis, and the delivery of growth hormone. The Implantable Programmable Infusion Pump (IPIP) is the implanted element of PIMS. Under control of a microprocessor, the IPIP administers medication and stores data pertaining to its operation. An external unit can read out the stored data, as well as program the ...

  5. Pumps in nuclear power plants

    International Nuclear Information System (INIS)

    Kim, J.H.

    1991-01-01

    This paper reports that pumps play an important role in nuclear plant operation. For instance, reactor coolant pumps (RCPs) should provide adequate cooling for reactor core in both normal operation and transient or accident conditions. Pumps such as Low Pressure Safety Injection (LPSI) pump in the Emergency Core Cooling System (ECCS) play a crucial role during an accident, and their reliability is of paramount importance. Some key issues involved with pumps in nuclear plant system include the performance of RCP under two-phase flow conditions, piping vibration due to pump operating in two-phase flows, and reliability of LPSI pumps

  6. Inservice testing of vertical pumps

    International Nuclear Information System (INIS)

    Cornman, R.E. Jr.; Schumann, K.E.

    1994-01-01

    This paper focuses on the problems that may occur with vertical pumps while inservice tests are conducted in accordance with existing American Society of Mechanical Engineers Code, Section XI, standards. The vertical pump types discussed include single stage, multistage, free surface, and canned mixed flow pumps. Primary emphasis is placed on the hydraulic performance of the pump and the internal and external factors to the pump that impact hydraulic performance. In addition, the paper considers the mechanical design features that can affect the mechanical performance of vertical pumps. The conclusion shows how two recommended changes in the Code standards may increase the quality of the pump's operational readiness assessment during its service life

  7. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  8. Failure mode and effects analysis applied to the administration of liquid medication by oral syringes

    Directory of Open Access Journals (Sweden)

    Eva María Guerra-Alia

    2017-11-01

    Full Text Available To carry out a Failure Mode and Effects Analysis (FMEA to the use of oral syringes. Methods: A multidisciplinary team was assembled within the Safety Committee. The stages of oral administration process of liquid medication were analysed, identifying the most critical and establishing the potential modes of failure that can cause errors. The impact associated with each mode of failure was calculated using the Risk Priority Number (RPN. Preventive actions were proposed. Results: Five failure modes were identified, all classified as high risk (RPN> 100. Seven of the eight preventive actions were implemented. Conclusions: The FMEA methodology was a useful tool. It has allowed to know the risks, analyse the causes that cause them, their effects on patient safety and the measures to reduce them

  9. 3D Printing Prototypes for Healthcare Professionals: Creating a Reciprocating Syringe.

    Science.gov (United States)

    Rothenberg, Steven; Abdullah, Selwan; Hirsch, Jeffrey

    2017-10-01

    3D printing (additive manufacturing) has been around since 1984, but interest in the technology has increased exponentially as it has become both accessible and inexpensive. The applications of the technology in healthcare are still being explored; however, initial forays have been encouraging. It has the potential to revolutionize the process of prototyping for healthcare professionals by democratizing the process and enhancing collaboration, making it cheaper to do iterative prototyping with little or no engineering experience. This case report details the creation of a multi-lumen reciprocating syringe with 3D printing. The product has been created and tested using a variety of publicly available resources. It provides a detailed overview of the approach and the framework required to create such a medical device. However, the implications of this report are much larger than this one product, and the fundamental ideas discussed here could be used for creating customized solutions for many healthcare problems.

  10. Evidence-based policy versus morality policy: the case of syringe access programs.

    Science.gov (United States)

    de Saxe Zerden, Lisa; O'Quinn, Erin; Davis, Corey

    2015-01-01

    Evidence-based practice (EBP) combines proven interventions with clinical experience, ethics, and client preferences to inform treatment and services. Although EBP is integrated into most aspects of social work and public health, at times EBP is at odds with social policy. In this article the authors explore the paradox of evidence-based policy using syringe access programs (SAP) as a case example, and review methods of bridging the gap between the emphasis on EBP and lack of evidence informing SAP policy. Analysis includes the overuse of morality policy and examines historical and current theories why this paradox exists. Action steps are highlighted for creating effective policy and opportunities for public health change. Strategies on reframing the problem and shifting target population focus to garner support for evidence-based policy change are included. This interdisciplinary understanding of the way in which these factors converge is a critical first step in moving beyond morality-based policy toward evidence-based policy.

  11. A rapid and economic in-house DNA purification method using glass syringe filters.

    Directory of Open Access Journals (Sweden)

    Yun-Cheol Kim

    Full Text Available BACKGROUND: Purity, yield, speed and cost are important considerations in plasmid purification, but it is difficult to achieve all of these at the same time. Currently, there are many protocols and kits for DNA purification, however none maximize all four considerations. METHODOLOGY/PRINCIPAL FINDINGS: We now describe a fast, efficient and economic in-house protocol for plasmid preparation using glass syringe filters. Plasmid yield and quality as determined by enzyme digestion and transfection efficiency were equivalent to the expensive commercial kits. Importantly, the time required for purification was much less than that required using a commercial kit. CONCLUSIONS/SIGNIFICANCE: This method provides DNA yield and quality similar to that obtained with commercial kits, but is more rapid and less costly.

  12. Anterior and middle superior alveolar nerve block for anesthesia of maxillary teeth using conventional syringe

    Directory of Open Access Journals (Sweden)

    Ignacio Velasco

    2012-01-01

    Full Text Available Background: Dental procedures in the maxilla typically require multiple injections and may inadvertently anesthetize facial structures and affect the smile line. To minimize these inconveniences and reduce the number of total injections, a relatively new injection technique has been proposed for maxillary procedures, the anterior and middle superior alveolar (AMSA nerve block, which achieves pulpal anesthesia from the central incisor to second premolar through palatal approach with a single injection. The purpose of this article is to provide background information on the anterior and middle superior alveolar nerve block and demonstrate its success rates of pulpal anesthesia using the conventional syringe. Materials and Methods: Thirty Caucasian patients (16 men and 14 women with an average age of 22 years-old, belonging to the School of Dentistry of Los Andes University, were selected. All the patients received an AMSA nerve block on one side of the maxilla using the conventional syringe, 1 ml of lidocaine 2% with epinephrine 1:100.000 was injected to all the patients. Results: The AMSA nerve block obtained a 66% anesthetic success in the second premolar, 40% in the first premolar, 60% in the canine, 23.3% in the lateral incisor, and 16.7% in the central incisor. Conclusions: Because of the unpredictable anesthetic success of the experimental teeth and variable anesthesia duration, the technique is disadvantageous for clinical application as the first choice, counting with other techniques that have greater efficacy in the maxilla. Although, anesthetizing the teeth without numbing the facial muscles may be useful in restorative dentistry.

  13. Syringe-Injectable Electronics with a Plug-and-Play Input/Output Interface.

    Science.gov (United States)

    Schuhmann, Thomas G; Yao, Jun; Hong, Guosong; Fu, Tian-Ming; Lieber, Charles M

    2017-09-13

    Syringe-injectable mesh electronics represent a new paradigm for brain science and neural prosthetics by virtue of the stable seamless integration of the electronics with neural tissues, a consequence of the macroporous mesh electronics structure with all size features similar to or less than individual neurons and tissue-like flexibility. These same properties, however, make input/output (I/O) connection to measurement electronics challenging, and work to-date has required methods that could be difficult to implement by the life sciences community. Here we present a new syringe-injectable mesh electronics design with plug-and-play I/O interfacing that is rapid, scalable, and user-friendly to nonexperts. The basic design tapers the ultraflexible mesh electronics to a narrow stem that routes all of the device/electrode interconnects to I/O pads that are inserted into a standard zero insertion force (ZIF) connector. Studies show that the entire plug-and-play mesh electronics can be delivered through capillary needles with precise targeting using microliter-scale injection volumes similar to the standard mesh electronics design. Electrical characterization of mesh electronics containing platinum (Pt) electrodes and silicon (Si) nanowire field-effect transistors (NW-FETs) demonstrates the ability to interface arbitrary devices with a contact resistance of only 3 Ω. Finally, in vivo injection into mice required only minutes for I/O connection and yielded expected local field potential (LFP) recordings from a compact head-stage compatible with chronic studies. Our results substantially lower barriers for use by new investigators and open the door for increasingly sophisticated and multifunctional mesh electronics designs for both basic and translational studies.

  14. Syringe needle skull penetration reduces brain injuries and secondary inflammation following intracerebral neural stem cell transplantation.

    Science.gov (United States)

    Gao, Mou; Dong, Qin; Zhang, Hongtian; Yang, Yang; Zhu, Jianwei; Yang, Zhijun; Xu, Minhui; Xu, Ruxiang

    2017-03-01

    Intracerebral neural stem cell (NSC) transplantation is beneficial for delivering stem cell grafts effectively, however, this approach may subsequently result in brain injury and secondary inflammation. To reduce the risk of promoting brain injury and secondary inflammation, two methods were compared in the present study. Murine skulls were penetrated using a drill on the left side and a syringe needle on the right. Mice were randomly divided into three groups (n=84/group): Group A, receiving NSCs in the left hemisphere and PBS in the right; group B, receiving NSCs in the right hemisphere and PBS in the left; and group C, receiving equal NSCs in both hemispheres. Murine brains were stained for morphological analysis and subsequent evaluation of infiltrated immune cells. ELISA was performed to detect neurotrophic and immunomodulatory factors in the brain. The findings indicated that brain injury and secondary inflammation in the left hemisphere were more severe than those in the right hemisphere, following NSC transplantation. In contrast to the left hemisphere, more neurotrophic factors but less pro-inflammatory cytokines were detected in the right hemisphere. In addition, increased levels of neurotrophic factors and interleukin (IL)-10 were observed in the NSC transplantation side when compared with the PBS-treated hemispheres, although lower levels of IL-6 and tumor necrosis factor-α were detected. In conclusion, the present study indicated that syringe needle skull penetration vs. drill penetration is an improved method that reduces the risk of brain injury and secondary inflammation following intracerebral NSC transplantation. Furthermore, NSCs have the potential to modulate inflammation secondary to brain injuries.

  15. Syringeal specialization of frequency control during song production in the Bengalese finch (Lonchura striata domestica.

    Directory of Open Access Journals (Sweden)

    Kristen R Secora

    Full Text Available Singing in songbirds is a complex, learned behavior which shares many parallels with human speech. The avian vocal organ (syrinx has two potential sound sources, and each sound generator is under unilateral, ipsilateral neural control. Different songbird species vary in their use of bilateral or unilateral phonation (lateralized sound production and rapid switching between left and right sound generation (interhemispheric switching of motor control. Bengalese finches (Lonchura striata domestica have received considerable attention, because they rapidly modify their song in response to manipulations of auditory feedback. However, how the left and right sides of the syrinx contribute to acoustic control of song has not been studied.Three manipulations of lateralized syringeal control of sound production were conducted. First, unilateral syringeal muscular control was eliminated by resection of the left or right tracheosyringeal portion of the hypoglossal nerve, which provides neuromuscular innervation of the syrinx. Spectral and temporal features of song were compared before and after lateralized nerve injury. In a second experiment, either the left or right sound source was devoiced to confirm the role of each sound generator in the control of acoustic phonology. Third, air pressure was recorded before and after unilateral denervation to enable quantification of acoustic change within individual syllables following lateralized nerve resection.These experiments demonstrate that the left sound source produces louder, higher frequency, lower entropy sounds, and the right sound generator produces lower amplitude, lower frequency, higher entropy sounds. The bilateral division of labor is complex and the frequency specialization is the opposite pattern observed in most songbirds. Further, there is evidence for rapid interhemispheric switching during song production. Lateralized control of song production in Bengalese finches may enhance acoustic

  16. The provision of non-needle/syringe drug injecting paraphernalia in the primary prevention of HCV among IDU: a systematic review

    Directory of Open Access Journals (Sweden)

    Ahmed Syed

    2010-11-01

    Full Text Available Abstract Background Sharing drug injecting paraphernalia other than needles and syringes (N/S has been implicated in the transmission of Hepatitis C virus (HCV among injecting drug users (IDU. We aimed to determine whether the provision of sterile non-N/S injecting paraphernalia reduces injecting risk behaviours or HCV transmission among IDU. Methods A systematic search of seven databases and the grey literature for articles published January 1989-February 2010 was undertaken. Thirteen studies (twelve observational and one non-randomized uncontrolled pilot intervention were identified and appraised for study design and quality by two investigators. Results No studies examined the association between the provision of non-N/S injecting paraphernalia and incident HCV infection. One cross-sectional study found that individuals who frequently, compared to those who infrequently, used sterile cookers and water, were less likely to report prevalent HCV infection. Another found no association between the uptake of sterile non-N/S injecting paraphernalia and self-reported sharing of this paraphernalia. The remaining observational studies used attendance at needle and syringe exchange programmes (NSP or safer injection facilities (SIF that provided non-N/S injecting paraphernalia as a proxy measure. Eight studies presented adjusted odds ratios, ranging from 0.3 to 0.9, suggesting a reduced likelihood of self-reported sharing of non-N/S injecting paraphernalia associated with use of NSP or SIF. There was substantial uncertainty associated with these estimates however. Three unadjusted studies reported a reduction in the prevalence of sharing of non-N/S injecting paraphernalia over time among NSP users. Only one study reported an adjusted temporal trend in the prevalence of sharing non-N/S injecting paraphernalia, finding higher rates among non-NSP users than NSP users at each time point, and a greater reduction in sharing among non-NSP than NSP users over

  17. Contact with hospital syringes containing body fluids: implications for medical waste management regulation Jeringas en contacto con sangre y fluidos corporales utilizadas en el hospital: implicaciones para el manejo de desechos hospitalarios

    OpenAIRE

    Patricia Volkow; Bénédicte Jacquemin; Diana Vilar-Compte; José Ramón Castillo

    2003-01-01

    OBJECTIVE: To determine amount of syringes used in the hospital and extent of contact with blood and body fluids of these syringes. MATERIAL AND METHODS: Syringe use was surveyed at a tertiary care center for one week; syringes were classified into the following four categories according to use: a) contained blood; b) contained other body fluids (urine, gastric secretion, cerebrospinal fluid, wound drainage); c) used exclusively for drug dilution and application in plastic intravenous (IV) tu...

  18. Prospects for a wind pump industry in Sri Lanka

    International Nuclear Information System (INIS)

    Fernando, S.

    1991-01-01

    Since 1977 considerable effort has been made in Sri Lanka to develop and disseminate wind pumping systems primarily in the small-scale agricultural sector in the island's dry zone. Through close cooperation with the Consultancy Services Wind Energy Developing Countries (CWD) in the Netherlands this programme has been successful in developing the necessary hardware but the broad objective of promoting wide spread use of wind pumping in Sri Lanka is yet to materialize. In analyzing probable reasons for this, the paper highlights that the basic arguments underlying the origin of the project in 1976, such as foreign exchange savings and local industrial development, became irrelevant to the post 1977 political and economic policies of the new government. Thus, the general economic framework adopted in Sri Lanka since 1977 does not seem to provide the necessary pre-conditions for development of a local industry for wind pumps. Due to this reason and the fact that kerosene oil used in conventional agriculturla pumps is subsidized, the ability of wind pumps to compete in the wind pump market seems highly constrained. It is concluded that under such conditions the prospects for the manufacturing and marketing of wind pumps on an industrial scale are not very favourable

  19. [Incorrect programming of a target controlled infusion pump. Case SENSAR of the trimester].

    Science.gov (United States)

    2014-10-01

    We report the case of a patient who underwent surgical aortic valve replacement. During general anaesthesia maintenance, the patient received a remifentanyl infusion via a target controlled infusion (TCI) system. The infusion pump that was prepared to deliver the infusion showed malfunction at the beginning of the surgery, so it was quickly replaced with a second pump. After a few minutes into the surgery, the patient presented with hypotension refractory to treatment. The remifentanyl syringe also emptied faster than expected. On reviewing the TCI pump, it was found that it was erroneously programmed for propofol instead of remifentanyl, thus the patient had received a very high dose of remifentanyl that was probably the cause of the haemodynamic disturbances. The incident was an error in equipment use, facilitated by hurry, lack of checking of the equipment prior to its use, and the complex and unclear design of the devices' screens. After analysis of this incident, all TCI pumps were reviewed, and all the programs for infrequently used drugs were deleted. Furthermore, 2 pumps were selected for exclusive use in the cardiac surgery theatre, one with propofol-only programming, and the other with remifentanyl-only programming, both clearly marked and situated in fixed places in that theatre. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  20. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  1. Wet motor geroter fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Wiernicki, M.V.

    1987-05-05

    This patent describes a wet motor gerotor fuel pump for pumping fuel from a fuel source to an internal combustion which consists of: gerotor pump means comprising an inner pump gear, an outer pump gear, and second tang means located on one of the inner and outer pump gears. The second tang means further extends in a second radial direction radially offset from the first radial direction and forms a driving connection with the first tang means such that the fuel pump pumps fuel from the fuel source into the narrow conduit inlet chamber, through the gerotor pump means past the electric motor means into the outlet housing means substantially along the flow axis to the internal combustion engine.

  2. Fusion reactor pumped laser

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1988-01-01

    A nuclear pumped laser is described comprising: a toroidal fusion reactor, the reactor generating energetic neutrons; an annular gas cell disposed around the outer periphery of the reactor, the cell including an annular reflecting mirror disposed at the bottom of the cell and an annular output window disposed at the top of the cell; a gas lasing medium disposed within the annular cell for generating output laser radiation; neutron reflector material means disposed around the annular cell for reflecting neutrons incident thereon back into the gas cell; neutron moderator material means disposed between the reactor and the gas cell and between the gas cell and the neutron reflector material for moderating the energy of energetic neutrons from the reactor; converting means for converting energy from the moderated neutrons to energy pumping means for pumping the gas lasing medium; and beam compactor means for receiving output laser radiation from the annular output window and generating a single output laser beam therefrom

  3. Are major reductions in new HIV infections possible with people who inject drugs? The case for low dead-space syringes in highly affected countries.

    Science.gov (United States)

    Zule, William A; Cross, Harry E; Stover, John; Pretorius, Carel

    2013-01-01

    Circumstantial evidence from laboratory studies, mathematical models, ecological studies and bio behavioural surveys, suggests that injection-related HIV epidemics may be averted or reversed if people who inject drugs (PWID) switch from using high dead-space to using low dead-space syringes. In laboratory experiments that simulated the injection process and rinsing with water, low dead space syringes retained 1000 times less blood than high dead space syringes. In mathematical models, switching PWID from high dead space to low dead space syringes prevents or reverses injection-related HIV epidemics. No one knows if such an intervention is feasible or what effect it would have on HIV transmission among PWID. Feasibility studies and randomized controlled trials (RCTs) will be needed to answer these questions definitively, but these studies will be very expensive and take years to complete. Rather than waiting for them to be completed, we argue for an approach similar to that used with needle and syringe programs (NSP), which were promoted and implemented before being tested more rigorously. Before implementation, rapid assessments that involve PWID will need to be conducted to ensure buy-in from PWID and other local stakeholders. This commentary summarizes the existing evidence regarding the protective effects of low dead space syringes and estimates potential impacts on HIV transmission; it describes potential barriers to transitioning PWID from high dead space to low dead space needles and syringes; and it presents strategies for overcoming these barriers. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  5. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  6. Acoustical heat pumping engine

    Science.gov (United States)

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1983-08-16

    The disclosure is directed to an acoustical heat pumping engine without moving seals. A tubular housing holds a compressible fluid capable of supporting an acoustical standing wave. An acoustical driver is disposed at one end of the housing and the other end is capped. A second thermodynamic medium is disposed in the housing near to but spaced from the capped end. Heat is pumped along the second thermodynamic medium toward the capped end as a consequence both of the pressure oscillation due to the driver and imperfect thermal contact between the fluid and the second thermodynamic medium. 2 figs.

  7. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  8. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  9. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  10. Carbon sheet pumping

    International Nuclear Information System (INIS)

    Ohyabu, N.; Sagara, A.; Kawamura, T.; Motojima, O.; Ono, T.

    1993-07-01

    A new hydrogen pumping scheme has been proposed which controls recycling of the particles for significant improvement of the energy confinement in toroidal magnetic fusion devices. In this scheme, a part of the vacuum vessel surface near the divertor is covered with carbon sheets of a large surface area. Before discharge initiation, the sheets are baked up to 700 ∼ 1000degC to remove the previously trapped hydrogen atoms. After being cooled down to below ∼ 200degC, the unsaturated carbon sheets trap high energy charge exchange hydrogen atoms effectively during a discharge and overall pumping efficiency can be as high as ∼ 50 %. (author)

  11. Vacuum pumping concepts for ETF

    International Nuclear Information System (INIS)

    Homeyer, W.G.

    1980-09-01

    The Engineering Test Facility (ETF) poses unique vacuum pumping requirements due to its large size and long burn characteristics. These requirements include torus vacuum pumping initially and between burns and pumping of neutralized gas from divertor collector chambers. It was found that the requirements could be met by compound cryopumps in which molecular sieve 5A is used as the cryosorbent. The pumps, ducts, and vacuum valves required are large but fit with other ETF components and do not require major advances in vacuum pumping technology. Several additional design, analytical, and experimental studies were identified as needed to optimize designs and provide better design definition for the ETF vacuum pumping systems

  12. Ghana's nuclear programme

    International Nuclear Information System (INIS)

    Ahafia, Albert K.

    1988-01-01

    The Paper gives the purpose of Ghana's Nuclear Programme and describes some specific research activities and peaceful applications of atomic energy in agriculture, medicine and industry. A discussion of some of the problem facing the programme concludes the Paper. (author)

  13. Study of Hydrogen Pumping through Condensed Argon in Cryogenic pump

    International Nuclear Information System (INIS)

    Jadeja, K A; Bhatt, S B

    2012-01-01

    In ultra high vacuum (UHV) range, hydrogen is a dominant residual gas in vacuum chamber. Hydrogen, being light gas, pumping of hydrogen in this vacuum range is limited with widely used UHV pumps, viz. turbo molecular pump and cryogenic pump. Pre condensed argon layers in cryogenic pump create porous structure on the surface of the pump, which traps hydrogen gas at a temperature less than 20° K. Additional argon gas injection in the cryogenic pump, at lowest temperature, generates multiple layers of condensed argon as a porous frost with 10 to 100 A° diameters pores, which increase the pumping capacity of hydrogen gas. This pumping mechanism of hydrogen is more effective, to pump more hydrogen gas in UHV range applicable in accelerator, space simulation etc. and where hydrogen is used as fuel gas like tokamak. For this experiment, the cryogenic pump with a closed loop refrigerator using helium gas is used to produce the minimum cryogenic temperature as ∼ 14° K. In this paper, effect of cryosorption of hydrogen is presented with different levels of argon gas and hydrogen gas in cryogenic pump chamber.

  14. Solar pumped laser

    Science.gov (United States)

    Lee, J. H.; Hohl, F.; Weaver, W. R. (Inventor)

    1984-01-01

    A solar pumped laser is described in which the lasant is a gas that will photodissociate and lase when subjected to sunrays. Sunrays are collected and directed onto the gas lasant to cause it to lase. Applications to laser propulsion and laser power transmission are discussed.

  15. Cryogenic vacuum pump design

    International Nuclear Information System (INIS)

    Bartlett, A.J.; Lessard, P.A.

    1984-01-01

    This paper is a review of the problems and tradeoffs involved in cryogenic vacuum pump analysis, design and manufacture. Particular attention is paid to the several issues unique to cryopumps, e.g., radiation loading, adsorption of noncondensible gases, and regeneration. A general algorithm for cryopump design is also proposed. 12 references

  16. Pump monitoring and analysis

    International Nuclear Information System (INIS)

    Guy, K.R.

    1992-01-01

    The paper describes how to set up a periodic vibration monitoring program implemented with electronic data loggers. Acquired data will be analyzed and evaluated to determine pump condition. Periodic measuring frequency, reporting procedures, and conditions of mechanical components are discussed in detail based on the actual case study

  17. Magnetic-flux pump

    Science.gov (United States)

    Hildebrandt, A. F.; Elleman, D. D.; Whitmore, F. C. (Inventor)

    1966-01-01

    A magnetic flux pump is described for increasing the intensity of a magnetic field by transferring flux from one location to the magnetic field. The device includes a pair of communicating cavities formed in a block of superconducting material, and a piston for displacing the trapped magnetic flux into the secondary cavity producing a field having an intense flux density.

  18. Putzmeister pumps for Tchernobyl

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Self-propelling concrete pumps are briefly described in this article, they comprise a 52-meter boom, a radiation protection, remote control, videocameras. Several units were ordered by the Soviet Union. The truck cabin is protected against radiation by a 10 millimeter thick shield in lead. 3 photographs [fr

  19. Scroll vacuum pump

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Etsuo; Suganami, Takuya; Nishida, Mitsuhiro; Kitora, Yoshihisa; Yamamoto, Sakuei; Fujii, Kosaburo

    1988-02-25

    An effort is made to apply a scroll machine to development of a vacuum pump. In view of mechanical simplification and load patterns, the vacuum pump uses a rotating mechanism to produce paired vortices rotating around each center. Chip seal and atmospheric pressure are utilized for axial gap sealing while a spring and atmospheric pressure for the radial gap sealing. In both gaps, the sealing direction is stationary relative to the environment during rotation, making it much easier to achieve effective sealing as compared to oscillating pumps. Since the compression ratio is high in vacuum pumps, a zero top clearance form is adopted for the central portion of vortices and an gas release valve is installed in the rotating axis. A compact Oldham coupling with a small inertia force is installed behind the vortices to maintain the required phase relations between the vortices. These improvements result in a vacuum of 1 Pa for dry operation and 10/sup -2/ Pa for oil flooded operation of a single-stage scroll machine at 1800 rpm. (5 figs, 1 tab, 4 refs)

  20. Centrifugal blood pump 603

    Indian Academy of Sciences (India)

    Centrifugal blood pump 603 pressure obtained for real blood, as shown in figure 6, is a little higher than that for glycerin aqua Solution with the same viscosity as blood. This may indicate the effect of slight non-. Newtonian turbulent flow. The radial whirl motion of the impeller was observed by dual laser position sensors.

  1. The Winfrith DSN programme

    International Nuclear Information System (INIS)

    Francescon, S.

    1963-05-01

    The programme, which is written in the Fortran language, solves the Carlson discrete S n approximation to the Boltzmann transport equation in cylindrical geometry. This report describes the input and output facilities of the WINFRITH DSN programme and the associated editing programme WED. (author)

  2. The Winfrith DSN programme

    Energy Technology Data Exchange (ETDEWEB)

    Francescon, S [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-05-15

    The programme, which is written in the Fortran language, solves the Carlson discrete S{sub n} approximation to the Boltzmann transport equation in cylindrical geometry. This report describes the input and output facilities of the WINFRITH DSN programme and the associated editing programme WED. (author)

  3. UNESCO's Ethics Education Programme.

    NARCIS (Netherlands)

    Have, H.A.M.J. ten

    2008-01-01

    Unesco initiated the Ethics Education Programme in 2004 at the request of member states to reinforce and increase the capacities in the area of ethics teaching. The programme is focused on providing detailed information about existing teaching programmes. It also develops and promotes teaching

  4. IEA HPT ANNEX 41 – Cold climate heat pumps: US country report

    Energy Technology Data Exchange (ETDEWEB)

    Groll, Eckhard A. [Purdue Univ., West Lafayette, IN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    In 2012 the International Energy Agency (IEA) Heat Pump Programme (now the Heat Pump Technologies (HPT) program) established Annex 41 to investigate technology solutions to improve performance of heat pumps for cold climates. Four IEA HPT member countries are participating in the Annex – Austria, Canada, Japan, and the United States (U.S.). The principal focus of Annex 41 is on electrically driven air-source heat pumps (ASHP) since that system type has the lowest installation cost of all heat pump alternatives. They also have the most significant performance challenges given their inherent efficiency and capacity issues at cold outdoor temperatures. Availability of ASHPs with improved low ambient performance would help bring about a much stronger heat pump market presence in cold areas, which today rely predominantly on fossil fuel furnace heating systems.

  5. Impulse pumping modelling and simulation

    International Nuclear Information System (INIS)

    Pierre, B; Gudmundsson, J S

    2010-01-01

    Impulse pumping is a new pumping method based on propagation of pressure waves. Of particular interest is the application of impulse pumping to artificial lift situations, where fluid is transported from wellbore to wellhead using pressure waves generated at wellhead. The motor driven element of an impulse pumping apparatus is therefore located at wellhead and can be separated from the flowline. Thus operation and maintenance of an impulse pump are facilitated. The paper describes the different elements of an impulse pumping apparatus, reviews the physical principles and details the modelling of the novel pumping method. Results from numerical simulations of propagation of pressure waves in water-filled pipelines are then presented for illustrating impulse pumping physical principles, and validating the described modelling with experimental data.

  6. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  7. Sludge pumping in water treatment

    International Nuclear Information System (INIS)

    Solar Manuel, M. A.

    2010-01-01

    In water treatment processes is frequent to separate residual solids, with sludge shape, and minimize its volume in a later management. the technologies to applicate include pumping across pipelines, even to long distance. In wastewater treatment plants (WWTP), the management of these sludges is very important because their characteristics affect load losses calculation. Pumping sludge can modify its behavior and pumping frequency can concern treatment process. This paper explains advantages and disadvantages of different pumps to realize transportation sludge operations. (Author) 11 refs.

  8. Vivitron dead section pumping tests

    International Nuclear Information System (INIS)

    Heugel, J.; Bayet, J.P.; Brandt, C.; Delhomme, C.; Krieg, C.; Kustner, F.; Meiss, R.; Riehl, R.; Roth, C.; Schlewer, B.; Six, P.; Weber, A.

    1990-10-01

    Pumping tests have been conducted on a simulated accelerator dead section. The behavior of different pump types are compared and analyzed. Vacuum conditions to be expected in the Vivitron are reached and several parameters are verified. Selection of a pump for the Vivitron dead section is confirmed

  9. Heat pumps are a dream

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    The fact that heat pumps do not achieve what their manufacturers promise in costs efficiency has been realized by the market. In 1981 the sales of heat pumps decreased by 50% of the 1980 market. Public utilities give the reason as economic, since fuel oil is too cheap. The author refutes this argument and presents arguments against heat pumps.

  10. Pumping characteristics of roots blower pumps for light element gases

    International Nuclear Information System (INIS)

    Hiroki, Seiji; Abe, Tetsuya; Tanzawa, Sadamitsu; Nakamura, Jun-ichi; Ohbayashi, Tetsuro

    2002-07-01

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H 2 , D 2 and He) and for N 2 , in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m 3 /s), two EH250s (ibid. 250 m 3 /s) and a backing pump (ibid. 100 m 3 /s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D 2 and N 2 were 1200 and 1300 m 3 /h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  11. A portable multi-syringe flow system for spectrofluorimetric determination of iodide in seawater.

    Science.gov (United States)

    Frizzarin, Rejane M; Aguado, Enrique; Portugal, Lindomar A; Moreno, Daniel; Estela, José M; Rocha, Fábio R P; Cerdà, Victor

    2015-11-01

    A miniaturized analyzer encompassing a poly(methyl methacrylate) chip with integrated spectrofluorimetric detection and solutions propelling by a multi-syringe module is proposed. Iodide was determined through its catalytic effect on the reaction between Ce(IV) and As(III). Matrix isopotential synchronous fluorescence was explored to set the excitation and emission wavelengths. A two-level full factorial design allowed to evaluate the significance of variables (Ce(IV), As(III) and H2SO4 concentrations) and their interaction effects in the experimental domain. A Doehlert Matrix was applied to identify the critical values. The optimized procedure showed a linear response from 1 to 100 μg L(-1) (S=53.7+2.61C, in which S is the net fluorescence and C is iodide concentration in μg L(-1)). Detection limit, coefficient of variation (n=6) and sampling rate were estimated at 0.3 μg L(-1), 0.8% and 20 h(-1), respectively. Recoveries within 90-117% were estimated for iodide spiked to seawater samples. The proposed procedure stands out because of the portability, robustness, and simplicity for in-field analysis of iodide in seawater. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Performance of a restrictive flow device and an electronic syringe driver for continuous subcutaneous infusion.

    Science.gov (United States)

    Capes, D; Martin, K; Underwood, R

    1997-10-01

    The aim of this study was to investigate the flow performance of the mechanical Springfusor 30 short model and the electronic Graseby MS16A. Flow rate was measured gravimetrically in a temperature-controlled cabinet. There was no statistically significant difference between the Graseby and Springfusor syringe drivers in the flow rate error at 25 degrees C. The percentage of flow rates within +/-20% accuracy during a 35-min periods at 25 degrees C was significantly less with the Graseby, being 91.9% compared with 100% for the Springfusor. Only 58.2% of flow rates with the Graseby were within the manufacturer claimed accuracy of +/-5%. The flow rate of the Springfusor was affected by temperature; at 30 degrees C the mean flow rate was 10.8% greater than at 25 degrees C. These results indicate that the Springfusor 30 had less flow rate variation than the Graseby MS16A. However, this would not be expected to cause noticeable clinical effects when used for opioid infusion in palliative care.

  13. A laser syringe aimed at delivering drug into the outer layer of human skin

    Science.gov (United States)

    Yoh, Jack J.; Jang, Hun-jae; Park, Mi-ae; Han, Tae-hee; Hah, Jung-moo

    2012-07-01

    A desire to eliminate hypodermic needle in transdermal drug delivery may now be realized. Imaging of the skin after injection of fluorescent probe and biotin via the bio-ballistic technique revealed the epidermal and dermal layers which were stained well below 60 μm underneath the abdominal skin of the guinea-pig. An extensive network of cells are shown in the deeper layer of the stained dermis as the distributed fluorescein isothiocyanate (FITC) dose is administered by repeated injection via the laser-based microjet. Here, we show our method of laser-based microjet drug delivery is capable of breaching guinea-pig's skin tissue and then delivering controlled dose of drug to the targeted region between 10 to 400 μm underneath the outermost layer of the skin. While minimizing pain and tissue damage by reducing the injection volume to ˜100 nl per pulse and the microjet diameter of half the conventional syringe needle in 100 μm, the optimally controlled delivery of liquid drug by the irradiated laser pulse is shown possible.

  14. Syringic Acid Extracted from Herba dendrobii Prevents Diabetic Cataract Pathogenesis by Inhibiting Aldose Reductase Activity

    Directory of Open Access Journals (Sweden)

    Xiaoyong Wei

    2012-01-01

    Full Text Available Objective. Effects of Syringic acid (SA extracted from dendrobii on diabetic cataract (DC pathogenesis were explored. Methods. Both in vitro and in vivo DC lens models were established using D-gal, and proliferation of HLEC exposed to SA was determined by MMT assay. After 60-day treatment with SA, rat lens transparency was observed by anatomical microscopy using a slit lamp. SA protein targets were extracted and isolated using 2-DE and MALDI TOF/TOF. AR gene expression was investigated using qRT-PCR. Interaction sites and binding characteristics were determined by molecule-docking techniques and dynamic models. Results. Targeting AR, SA provided protection from D-gal-induced damage by consistently maintaining lens transparency and delaying lens turbidity development. Inhibition of AR gene expression by SA was confirmed by qRT-PCR. IC50 of SA for inhibition of AR activity was 213.17 μg/mL. AR-SA binding sites were Trp111, His110, Tyr48, Trp20, Trp79, Leu300, and Phe122. The main binding modes involved hydrophobic interactions and hydrogen bonding. The stoichiometric ratio of non-covalent bonding between SA and AR was 1.0 to 13.3. Conclusion. SA acts to prevent DC in rat lenses by inhibiting AR activity and gene expression, which has potential to be developed into a novel drug for therapeutic management of DC.

  15. Safe intravenous administration in pediatrics: A 5-year Pediatric Intensive Care Unit experience with smart pumps.

    Science.gov (United States)

    Manrique-Rodríguez, S; Sánchez-Galindo, A C; Fernández-Llamazares, C M; Calvo-Calvo, M M; Carrillo-Álvarez, Á; Sanjurjo-Sáez, M

    2016-10-01

    To estimate the impact of smart pump implementation in a pediatric intensive care unit in terms of number and type of administration errors intercepted. Observational, prospective study carried out from January 2010 to March 2015 with syringe and great volumen infusion pumps available in the hospital. A tertiary level hospital pediatric intensive care unit. Infusions delivered with infusion pumps in all pediatric intensive care unit patients. Design of a drug library with safety limits for all intravenous drugs prescribed. Users' compliance with drug library as well as number and type of errors prevented were analyzed. Two hundred and eighty-three errors were intercepted during 62 months of study. A high risk drug was involved in 58% of prevented errors, such as adrenergic agonists and antagonists, sedatives, analgesics, neuromuscular blockers, opioids, potassium and insulin. Users' average compliance with the safety software was 84%. Smart pumps implementation has proven effective in intercepting high risk drugs programming errors. These results might be exportable to other critical care units, involving pediatric or adult patients. Interdisciplinary colaboration is key to succeed in this process. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  16. Treatment of herniated lumbar disc by percutaneous laser disc decompression combined with synchronous suction technique through syringe

    Institute of Scientific and Technical Information of China (English)

    Dhir B. Gurung; Gaojian Tao; Hongyi Lin; Yanning Qian; Jian Lin

    2007-01-01

    Objective: To compare the outcomes of percutaneous laser disc decompression (PLDD) and PLDD with synchronous suction through syringe in the patients with herniated lumbar disc (HLD). Methods: Forty-two patients with HLD on MRI and those who did not respond to conservative treatment for 6 weeks were randomly divided into group A and group B. In group A, the patients were treated with PLDD and those in group B with PLDD and synchronous suction through syringe. GaAIAS diode laser at 810 nm was used for the ablation in both groups. The treatment effect was evaluated by modified MacNab's criteria on the 7th, 30th and 90th day. Results: Evaluated by modified MacNab's criteria, the percentages of the excellent and good cases in total patients treated for group B and A were 80.95% and 57.14% on the 7th follow-up day, 85.71% and 66.67% on the 30th follow-up day, and 95.24% and 71.43% on the 90th follow-up day, respectively. Conclusion: Synchronous suction technique through syringe during PLDD improves the overall outcome in the treatment of herniated lumbar disc.

  17. Organic Extractives from Mentha spp. Honey and the Bee-Stomach: Methyl Syringate, Vomifoliol, Terpenediol I, Hotrienol and Other Compounds

    Directory of Open Access Journals (Sweden)

    Igor Jerković

    2010-04-01

    Full Text Available The GC and GC/MS analyses of the solvent organic extractive from the stomach of the bees, having collected Mentha spp. nectar, revealed the presence of methyl syringate (6.6%, terpendiol I (5.0% and vomifoliol (3.0% that can be attributed to the plant origin. Other major compounds from the bee-stomach were related to the composition of cuticular waxes and less to pheromones. Organic extractivesfrom Mentha spp. honey were obtained by solvent-free headspace solid-phase microextraction (HS-SPME and ultrasonic solvent extraction (USE and analyzed by GC and GC/MS. The major honey headspace compounds were hotrienol (31.1%–38.5%, 2-methoxy-4-methylphenol (0.5–6.0%, cis- and trans-linalool oxides (0.9–2.8%, linalool (1.0–3.1% and neroloxide (0.9–1.9%. Methyl syringate was the most abundant compound (38.3-56.2% in the honey solvent extractives followed by vomifoliol (7.0–26.6%. Comparison of the honey organic extractives with the corresponding bee-stomach extractive indicated that methyl syringate and vomofoliol were transferred to the honey while terpendiol I was partially transformed to hotrienol in ripened honey.

  18. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    Science.gov (United States)

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  19. Electroosmotic pumps for microflow analysis

    Science.gov (United States)

    Wang, Xiayan; Wang, Shili; Gendhar, Brina; Cheng, Chang; Byun, Chang Kyu; Li, Guanbin; Zhao, Meiping; Liu, Shaorong

    2009-01-01

    With rapid development in microflow analysis, electroosmotic pumps are receiving increasing attention. Compared to other micropumps, electroosmotic pumps have several unique features. For example, they are bi-directional, can generate constant and pulse-free flows with flow rates well suited to microanalytical systems, and can be readily integrated with lab-on-chip devices. The magnitude and the direction of flow of an electroosmotic pump can be changed instantly. In addition, electroosmotic pumps have no moving parts. In this article, we discuss common features, introduce fabrication technologies and highlight applications of electroosmotic pumps. PMID:20047021

  20. Bearing for liquid metal pump

    International Nuclear Information System (INIS)

    Dickinson, R.J.; Pennell, W.E.; Wasko, J.

    1984-01-01

    A liquid metal pump bearing support comprises a series of tangentially oriented spokes that connect the bearing cylinder to the pump internals structure. The spokes may be arranged in a plurality of planes extending from the bearing cylinder to the pump internals with the spokes in one plane being arranged alternately with those in the next plane. The bearing support structure provides the pump with sufficient lateral support for the bearing structure together with the capability of accommodating differential thermal expansion without adversely affecting pump performance

  1. Randomized, community-based pharmacy intervention to expand services beyond sale of sterile syringes to injection drug users in pharmacies in New York City.

    Science.gov (United States)

    Crawford, Natalie D; Amesty, Silvia; Rivera, Alexis V; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M

    2013-09-01

    Structural interventions may help reduce racial/ethnic disparities in HIV. In 2009 to 2011, we randomized pharmacies participating in a nonprescription syringe access program in minority communities to intervention (pharmacy enrolled and delivered HIV risk reduction information to injection drug users [IDUs]), primary control (pharmacy only enrolled IDUs), and secondary control (pharmacy did not engage IDUs). Intervention pharmacy staff reported more support for syringe sales than did control staff. An expanded pharmacy role in HIV risk reduction may be helpful.

  2. Thermo-electric pump

    International Nuclear Information System (INIS)

    Georges, J.-L.; Veyret, J.-F.

    1973-01-01

    Description is given of a thermo-pump for electrically conductive liquid fluids, e.g. for a liquid metal such as sodium. This pump is characterized in that the piping for the circulation of the conductive liquid is constituted by a plurality of conduits defined by two co-axial cylinders and two walls parallel to their axis. Each conduit limited outside by a magnet, inside by a mild-iron tube, and laterally by two materials forming a thermocouple. The electric current generated by that thermo-couple and the magnetic flux generated by the magnets both loop the loop through an outer cylindrical nickel shell. This can be applied to sodium circulation loops for testing nuclear fuel elements [fr

  3. Heat pumps: heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  4. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  5. Pocket pumped image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, I.V., E-mail: kotov@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Murray, N. [Centre for Electronic Imaging, Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2015-07-01

    The pocket pumping technique is used to detect small electron trap sites. These traps, if present, degrade CCD charge transfer efficiency. To reveal traps in the active area, a CCD is illuminated with a flat field and, before image is read out, accumulated charges are moved back and forth number of times in parallel direction. As charges are moved over a trap, an electron is removed from the original pocket and re-emitted in the following pocket. As process repeats one pocket gets depleted and the neighboring pocket gets excess of charges. As a result a “dipole” signal appears on the otherwise flat background level. The amplitude of the dipole signal depends on the trap pumping efficiency. This paper is focused on trap identification technique and particularly on new methods developed for this purpose. The sensor with bad segments was deliberately chosen for algorithms development and to demonstrate sensitivity and power of new methods in uncovering sensor defects.

  6. FTU pump limiter

    International Nuclear Information System (INIS)

    Alessandrini, C.; Ciotti, M.; Mattei, A. De; Maddaluno, G.; Mazzitelli, G.

    1989-01-01

    The control of the refuelling and recycling of the plasma is crucial in providing enhanced performances in tokamaks and steady-state operation in future reactors. In this paper, we report details of the design and analysis for the pump limiter to be incorporated into the FTU tokamak. The FTU, presently under commissioning, is a compact high field (B=8T), medium high density, circular cross section machine with small accesses. The dimensions of the equatorial port (width 8 cm) would reduce the length of the entrance throat to a few centimeters, which is unacceptable for efficient particle trapping. We have, therefore, designed a rotating blade of the pump limiter head that, in the working position, extends in the toroidal direction inside the vacuum chamber. (author) 8 refs., 4 figs

  7. Geothermal heat pump

    International Nuclear Information System (INIS)

    Bruno, R.; Tinti, F.

    2009-01-01

    In recent years, for several types of buildings and users, the choice of conditioning by heat pump and low enthalpy geothermal reservoir has been increasing in the Italian market. In fact, such systems are efficient in terms of energy and consumption, they can perform, even at the same time, both functions, heating and cooling and they are environmentally friendly, because they do not produce local emissions. This article will introduce the technology and will focus on critical points of a geothermal field design, from actual practice, to future perspectives for the geo exchanger improvement. Finally, the article presents a best practice case in Bologna district, with an economic analysis showing the convenience of a geothermal heat pump. Conclusions of the real benefits of these plants can be drawn: compared to a non-negligible initial cost, the investment has a pay-back period almost always acceptable, usually less than 10 years. [it

  8. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  9. 14 CFR 23.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 23.991 Section 23.991... § 23.991 Fuel pumps. (a) Main pumps. For main pumps, the following apply: (1) For reciprocating engine installations having fuel pumps to supply fuel to the engine, at least one pump for each engine must be directly...

  10. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    International Nuclear Information System (INIS)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H.; Mauck, William D.; Burke, Michelle M.

    2011-01-01

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  11. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    Energy Technology Data Exchange (ETDEWEB)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mauck, William D. [Mayo Clinic, Department of Anesthesiology, Rochester, MN (United States); Burke, Michelle M. [Mayo Clinic, Department of Psychiatry and Psychology, Rochester, MN (United States)

    2011-02-15

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  12. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  13. IRRIGATION USING SOLAR PUMP

    OpenAIRE

    Prof. Nitin P.Choudhary*1 & Ms. Komal Singne2

    2017-01-01

    In this report the described design of a PV and soil moisture sensor based automated irrigation system is introduced. This project aims to provide a human friendly, economical and automated water pumping system which eliminates the problems of over irrigation and helps in irrigation water optimization and manage it in accordance with the availability of water. Our project not only tries to modernize the irrigation practices and ensure the optimum yield by carefully fulfilling the requirements...

  14. Small size ion pumps

    International Nuclear Information System (INIS)

    Cyranski, R.; Kiliszek, Cz.R.; Marks, J.; Sobolewski, A.; Magielko, H.

    2001-01-01

    This paper describes some designs of the two versions ion pumps and their range operation for various magnetic fields. The first version is made with different cell size in the anode element and titanium cathode operating in magnetic field from 600 to 650 Gs and the second version with the same anode element but differential Ti/Ta cathode working in magnetic field above 1200 Gs

  15. Pumping potential wells

    Science.gov (United States)

    Hershkowitz, N.; Forest, C.; Wang, E. Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electro collecting anode in a relatively cold, low density multidipole plasma is considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important.

  16. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, all such structures must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which pump ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density, multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two-dimensional character of the problem is shown to be important

  17. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well, but steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important. (author)

  18. Jet operated heat pump

    International Nuclear Information System (INIS)

    Collard, T.H.

    1982-01-01

    A jet pump system is shown that utilizes waste heat to provide heating and/or cooling. Waste heat diverted through a boiler causes a refrigerant to evaporate and expand for supersonic discharge through a nozzle thereby creating a vacuum in an evaporator coil. The vacuum draws the refrigerant in a gaseous state into a condensing section of a jet pump along with refrigerant from a reservoir in a subcooled liquid form. This causes condensation of the gas in a condensation section of the jet pump, while moving at constant velocity. The change in momentum of the fluid overcomes the system high side pressure. Some of the condensate is cooled by a subcooler. Refrigerant in a subcooled liquid state from the subcooler is fed back into the evaporator and the condensing section with an adequate supply being insured by the reservoir. The motive portion of the condensate is returned to the boiler sans subcooling. By proper valving start-up is insured, as well as the ability to switch from heating to cooling

  19. Controlling groundwater pumping online.

    Science.gov (United States)

    Zekri, Slim

    2009-08-01

    Groundwater over-pumping is a major problem in several countries around the globe. Since controlling groundwater pumping through water flow meters is hardly feasible, the surrogate is to control electricity usage. This paper presents a framework to restrict groundwater pumping by implementing an annual individual electricity quota without interfering with the electricity pricing policy. The system could be monitored online through prepaid electricity meters. This provides low transaction costs of individual monitoring of users compared to the prohibitive costs of water flow metering and monitoring. The public groundwater managers' intervention is thus required to determine the water and electricity quota and watch the electricity use online. The proposed framework opens the door to the establishment of formal groundwater markets among users at very low transaction costs. A cost-benefit analysis over a 25-year period is used to evaluate the cost of non-action and compare it to the prepaid electricity quota framework in the Batinah coastal area of Oman. Results show that the damage cost to the community, if no active policy is implemented, amounts to (-$288) million. On the other hand, the implementation of a prepaid electricity quota with an online management system would result in a net present benefit of $199 million.

  20. Liquid sodium pumps

    International Nuclear Information System (INIS)

    Allen, H.G.

    1985-01-01

    The pump for use in a nuclear reactor cooling system comprises a booster stage impeller for drawing the liquid through the inlet. A diffuser is affixedly disposed within the pump housing to convert the kinetic pressure imparted to the liquid into increased static pressure. A main stage impeller is rotatively driven by a pump motor at a relatively high speed to impart a relatively high static pressure to the liquid and for discharging the liquid at a relatively high static pressure. A hydraulic coupling is disposed remotely from the liquid path for hydraulically coupling the main stage impeller and the booster stage impeller to rotate the booster stage impeller at a relatively low speed to maintain the low net positive suction pressure applied to the liquid at the inlet greater than the vapor pressure of the liquid and to ensure that the low net positive suction heat, as established by the main stage impeller exceeds the vapor pressure. The coupling comprises a grooved drum which rotates between inner and outer drag coupling members. In a modification the coupling comprises a torque converter. (author)

  1. Electrocentrifugal pumping; Bombeo electrocentrifugo

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perez, Guillermo; Medellin Otero, Hector [Instituto Mexicano del Peroleo (Mexico)

    1996-07-01

    The exploitation of isolated oil deposits, in losing their own energy, enter a phase of secondary recovery. One of the technologies of new development in Mexico is the one of electrocentrifugal pumping , which consists of introducing the motor-pump as an integral part of the production pipe down to the well bottom and pumping directly up to central complexes, from where it is sent inland. In the present paper is intended to explain what this type of secondary recovery consists of. [Spanish] La explotacion de yacimientos aislados de petroleo, al perder su energia propia, entran en una fase de recuperacion secundaria. Una de las tecnologias de nuevo desarrollo en Mexico es la de bombeo electrocentrifugo, la cual consiste en introducir la motobomba como parte integral de la tuberia de produccion hasta el fondo del pozo y bombearlo directamente hasta los complejos centrales, de donde se envia a tierra. En el presente trabajo se pretende explicar en que consiste este tipo de recuperacion secundaria.

  2. Optically pumped terahertz sources

    Institute of Scientific and Technical Information of China (English)

    ZHONG Kai; SHI Wei; XU DeGang; LIU PengXiang; WANG YuYe; MEI JiaLin; YAN Chao; FU ShiJie; YAO JianQuan

    2017-01-01

    High-power terahertz (THz) generation in the frequency range of0.1-10 THz has been a fast-developing research area ever since the beginning of the THz boom two decades ago,enabling new technological breakthroughs in spectroscopy,communication,imaging,etc.By using optical (laser) pumping methods with near-or mid-infrared (IR) lasers,flexible and practical THz sources covering the whole THz range can be realized to overcome the shortage of electronic THz sources and now they are playing important roles in THz science and technology.This paper overviews various optically pumped THz sources,including femtosecond laser based ultrafast broadband THz generation,monochromatic widely tunable THz generation,single-mode on-chip THz source from photomixing,and the traditional powerful THz gas lasers.Full descriptions from basic principles to the latest progress are presented and their advantages and disadvantages are discussed as well.It is expected that this review gives a comprehensive reference to researchers in this area and additionally helps newcomers to quickly gain understanding of optically pumped THz sources.

  3. In-syringe magnetic-stirring-assisted liquid-liquid microextraction for the spectrophotometric determination of Cr(VI) in waters.

    Science.gov (United States)

    Henríquez, Camelia; Horstkotte, Burkhard; Solich, Petr; Cerdà, Víctor

    2013-08-01

    A fully automated method for the determination of chromate is described. It is based on the selective reaction of Cr(VI) with diphenylcarbazide in acidic media to form a colored complex of Cr(III) with the oxidation product diphenylcarbazone. The reaction was performed within the syringe of an automatic burette containing a magnetic stirrer for homogenization of the sample and the required reagents. In-syringe stirring was made possible using a specially designed driving device placed around the syringe barrel to achieve a rotating magnetic field in the syringe, forcing the stirrer to spin. In a second step, the reaction mixture in the syringe was neutralized to allow in-syringe magnetic-stirring-assisted dispersive liquid-liquid microextraction of the complex into 125 μL of n-hexanol. After phase separation by droplet flotation over 30 s, the organic phase was propelled into a coupled spectrophotometric detection cell. The entire multistep procedure including in-system standard preparation was done within 270 s. The method was used for the analysis of natural waters, achieving average analyte recovery of 103%, a limit of detection of 0.26 μg L(-1), and a repeatability of less than 4% relative standard deviation.

  4. [Safe injection rooms and police crackdowns in areas with heavy drug dealing. Evaluation by counting discarded syringes collected from the public space].

    Science.gov (United States)

    Vecino, Carmen; Villalbí, Joan R; Guitart, Anna; Espelt, Albert; Bartroli, Montserrat; Castellano, Yolanda; Brugal, M Teresa

    2013-01-01

    The evolution of drug injection in public places is analysed using as indicator the number of syringes collected from public spaces, evaluating as well the influence of public health harm reduction interventions and of police actions, with a before and after quasi experimental study. Monthly syringe counts on the semester before and after each intervention were compared both in the involved district and in the city as a whole, using the U and z tests with a 95% confidence level. The average number of collected syringes drops from 13.132 in 2004 to 3.190 in 2012. Comparing indicators before and after health and police interventions, the opening of a facility with a supervised drug consumption room in the inner city was associated with a huge reduction in the number of abandoned syringes in the city, while its number did not rise in the district where the facility was located. The subsequent opening of another drug consumption room did not have a significant impact in collected syringes in the area. Some police interventions in 2005-2006 and 2011 had a significant impact in the indicators of the involved districts, while others did not. Harm reduction programs might have a favourable impact on drug injection in public spaces and related syringe presence. Some police interventions appear to have an impact while others do not or just have a modest local and temporary effect.

  5. The photovoltaic programme in India. An overview

    International Nuclear Information System (INIS)

    Sastry, E.V.R.

    1997-01-01

    This paper gives an outline of the development and implementation of the PV programme in India, which goes back to the mid 1970s. Industrial production, which began with indigenously developed single-crystal silicon technology, has now touched a level of 8 MW/yr. Among the applications being supported by the government are solar lighting, water pumping and small power plants. There is also a major segment of the market which is fully commercial. Plans for a further major expansion during the next five years are being developed

  6. On-line lab-in-syringe cloud point extraction for the spectrophotometric determination of antimony.

    Science.gov (United States)

    Frizzarin, Rejane M; Portugal, Lindomar A; Estela, José M; Rocha, Fábio R P; Cerdà, Victor

    2016-02-01

    Most of the procedures for antimony determination require time-consuming sample preparation (e.g. liquid-liquid extraction with organic solvents), which are harmful to the environment. Because of the high antimony toxicity, a rapid, sensitive and greener procedure for its determination becomes necessary. The goal of this work was to develop an analytical procedure exploiting for the first time the cloud point extraction on a lab-in-syringe flow system aiming at the spectrophotometric determination of antimony. The procedure was based on formation of an ion-pair between the antimony-iodide complex and H(+) followed by extraction with Triton X-114. The factorial design showed that the concentrations of ascorbic acid, H2SO4 and Triton X-114, as well as second and third order interactions were significant at the 95% confidence level. A Box-Behnken design was applied to obtain the response surfaces and to identify the critical values. System is robust at the 95% confidence level. A linear response was observed from 5 to 50 µg L(-1), described by the equation A=0.137+0.050C(Sb) (r=0.998). The detection limit (99.7% confidence level), the coefficient of variation (n=5; 15 µg L(-1)) and the sampling rate was estimated at 1.8 µg L(-1), 1.6% and 16 h(-1), respectively. The procedure allows quantification of antimony in the concentrations established by environmental legislation (6 µg L(-1)) and it was successfully applied to the determination of antimony in freshwater samples and antileishmanial drugs, yielding results in agreement with those obtained by HGFAAS at the 95% confidence level. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Needle and syringe programs in Yunnan, China yield health and financial return

    Directory of Open Access Journals (Sweden)

    Xun Zhuang

    2011-04-01

    Full Text Available Abstract Background As a harm reduction strategy in response to HIV epidemics needle and syringes programs (NSPs were initiated throughout China in 2002. The effectiveness of NSPs in reducing the spread of infection in such an established epidemic is unknown. In this study we use data from Yunnan province, the province most affected by HIV in China, to (1 estimate the population benefits in terms of infections prevented due to the programs; (2 calculate the cost-effectiveness of NSPs. Methods We developed a mathematical transmission model, informed by detailed behavioral and program data, which accurately reflected the unique HIV epidemiology among Yunnan injecting drug users (IDUs in the presence of NSPs. We then used the model to estimate the likely epidemiological and clinical outcomes without NSPs and conducted a health economics analysis to determine the cost-effectiveness of the program. Results It is estimated that NSPs in Yunnan have averted approximately 16-20% (5,200-7,500 infections of the expected HIV cases since 2002 and led to gains of 1,300-1,900 DALYs. The total $1.04 million spending on NSPs from 2002 to 2008 has resulted in an estimated cost-saving over this period of $1.38-$1.97 million due to the prevention of HIV and the associated costs of care and management. Conclusion NSPs are not only cost-effective but cost-saving in Yunnan. Significant scale-up of NSPs interventions across China and removal of the societal and political barriers that compromise the effects of NSPs should be a health priority of the Chinese government.

  8. Supercritical waste oxidation pump investigation

    International Nuclear Information System (INIS)

    Thurston, G.; Garcia, K.

    1993-02-01

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications

  9. Finnish bioenergy research programme

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, D. [VTT Energy, Jyvaeskylae (Finland)

    1996-12-31

    Finland is a leading country in the use of biofuels and has excellent opportunities to increase the use of biofuels by up to 25-30 %. The Finnish Government has set an objective for the promotion of bioenergy. The aim is to increase the use of bioenergy by about 25 % from the present level by 2005, and the increment corresponds to 1.5 million tonnes of oil equivalent (toe) per year. The R and D work has been considered as an important factor to achieve this ambitious goal. Energy research was organised into a series of research programmes in 1988 in accordance with the proposal of Finnish Energy Research Committee. The object of the research programmes is to enhance research activities and to bundle individual projects together into larger research packages. The common target of the Finnish energy research programmes is to proceed from basic and applied research to product development and pilot operation, and after that to the first commercial applications, e.g. demonstrations. As the organisation of energy research to programmes has led to good results, the Finnish Ministry of Trade and Industry decided to go on with this practice by launching new six-year programmes in 1993-1998. One of these programmes is the Bioenergy Research Programme and the co-ordination of this programme is carried out by VTT Energy. Besides VTT Energy the Finnish Forest Research Institute, Work Efficiency Institute, Metsaeteho and University of Joensuu are participating in the programme 7 refs.

  10. Finnish bioenergy research programme

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, D [VTT Energy, Jyvaeskylae (Finland)

    1997-12-31

    Finland is a leading country in the use of biofuels and has excellent opportunities to increase the use of biofuels by up to 25-30 %. The Finnish Government has set an objective for the promotion of bioenergy. The aim is to increase the use of bioenergy by about 25 % from the present level by 2005, and the increment corresponds to 1.5 million tonnes of oil equivalent (toe) per year. The R and D work has been considered as an important factor to achieve this ambitious goal. Energy research was organised into a series of research programmes in 1988 in accordance with the proposal of Finnish Energy Research Committee. The object of the research programmes is to enhance research activities and to bundle individual projects together into larger research packages. The common target of the Finnish energy research programmes is to proceed from basic and applied research to product development and pilot operation, and after that to the first commercial applications, e.g. demonstrations. As the organisation of energy research to programmes has led to good results, the Finnish Ministry of Trade and Industry decided to go on with this practice by launching new six-year programmes in 1993-1998. One of these programmes is the Bioenergy Research Programme and the co-ordination of this programme is carried out by VTT Energy. Besides VTT Energy the Finnish Forest Research Institute, Work Efficiency Institute, Metsaeteho and University of Joensuu are participating in the programme 7 refs.

  11. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    OpenAIRE

    Li, Tao; Zhang, Weiming; Jiang, Ming; Li, Zhengyang

    2013-01-01

    A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Re...

  12. Insulin compatibility with polymer materials used in external pump infusion systems.

    Science.gov (United States)

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  13. Diode laser pumping

    International Nuclear Information System (INIS)

    Skagerlund, L.E.

    1975-01-01

    A diode laser is pumped or pulsed by a repeated capacitive discharge. A capacitor is periodically charged from a dc voltage source via a transformer, the capacitor being discharged through the diode laser via a controlled switching means after one or more charging periods. During a first interval of each charging period the transformer, while unloaded, stores a specific amount of energy supplied from the dc voltage source. During a subsequent interval of the charging period said specific amount of energy is transmitted from the transformer to the capacitor. The discharging of the capacitor takes place during a first interval of a charging period. (auth)

  14. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topolgies are suggested which allow high erosion without limiter failure

  15. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topologies are suggested which allow high erosion without limiter failure

  16. Improvements relating to electromagnetic pumps

    International Nuclear Information System (INIS)

    Davidson, D.F.

    1975-01-01

    Reference is made to electromagnetic pumps suitable for use in pumping molten Na, and particularly to annular linear induction pumps that may for example be used to pump molten Na at temperatures up to 650 0 in situations where it is not possible to provide cooling. Previous designs of such pumps have employed disk-shaped coils around the outside of the annulus, the coils being energised from a three-phase power supply to produce a travelling radial field. The pump system described obviates the necessity for joints between the coils. It also allows the use of all types of high temperature insultation, simplified manufacture, and enables the windings to be located on the inside of the annulus. Full constructional details are given. (U.K.)

  17. Fast breeder reactor electromagnetic pump

    International Nuclear Information System (INIS)

    Araseki, Hideo; Murakami, Takahiro

    2008-01-01

    Main pumps circulating sodium in the FBR type reactor have been mechanical types, not electromagnetic pumps. Electromagnetic pump of 1-2 m 3 /min has been used as an auxiliary pump. Large sized electromagnetic pumps such as several hundred m 3 /min have not been commercialized due to technical difficulties with electromagnetic instability and pressure pulsations. This article explained electromagnetic and fluid equations and magnetic Reynolds number related with electromagnetic pumps and numerical analysis of instability characteristics and pressure pulsations and then described applications of the results to FBR system. Magnetic Reynolds number must be chosen less than one with appropriate operating frequency and optimum slip of 0.2-0.4. (T. Tanaka)

  18. Mechanical pumping at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1994-12-31

    This new concept consists of a mechanical pump able to run at low temperature (25 K). Since gas density varies inversely with temperature, the pump could deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are reduction of an order of magnitude in size and weight when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. Results obtained at 80 K and 25 K with a Holweck type molecular drag pump of 100 mm diameter and with few stages of a turbomolecular pump running at the same temperatures, are given. This pump would be a solution to allow continuous tritium extraction and minimize the mass inventory for the ITER (International Tokamak Experiment Reactor). 5 figs., 2 tabs., 4 refs.

  19. Centrifugal pumps: fundamentals and classification

    International Nuclear Information System (INIS)

    Solar Manuel, A. M.

    2009-01-01

    Centrifugal pumps are usually employed to impulse water to elevate it, dose it or give it pressure or speed. They can be used with clean water or loaded with high solid concentration and don't work properly with air or another gas flow. There are another less used pumps, coming from volumetric or ram pumps to magnetic ones for specific uses. Centrifugal ones are rotokinetic pumps, like peripherical or lateral channel pumps. They work in a different way that non rotational kinetic ones and static ones. The work approaches their pre definition, selection, installation, operation and maintenance. It also review their morphology, hidromechanic principles and the basic elements pumps are made of. (Author)

  20. Specialists' meeting on cavitation criteria for designing mechanisms working in sodium: Application to pumps. Summary report

    International Nuclear Information System (INIS)

    2002-01-01

    The purpose of the meeting was to provide a forum for discussions and exchanges of views on cavitation phenomena in sodium, cavitation tests on pump models in water and sodium, application of test results to LMFBR plants, impact on sodium pump design. Topics of interest were also detection methods for cavitation during tests and cavitation problems in electro-magnetic pumps. Two categories of papers were presented: national position papers and specialised topical papers. The main topics discussed, in three sessions were the following: National papers on cavitation; cavitation tests, performance, measuring methods and results; application of test results and implications on the future programmes

  1. The design and testing of sodium pumps in the UK to meet the CDFR cavitation criteria

    International Nuclear Information System (INIS)

    Preece, G.E.; Macleod, I.D.; Wilkinson, D.

    2002-01-01

    A primary objective in the design of the sodium pumps for the UK Commercial Demonstration Fast Reactor has been to avoid cavitation during normal operation. This requirement arises from the need to avoid blade erosion and also, in the case of the Primary Sodium Pumps (PSP), the generation of cavitation noise which might otherwise interfere with instrumentation installed to detect noise of boiling in the core. This paper outlines the approach adopted to achieve a pump design with good cavitation performance and the programme of model testing carried out in a water loop to establish the cavitation boundaries for incipient cavitation of selected designs using both visual and acoustic techniques

  2. Considerations for reference pump curves

    International Nuclear Information System (INIS)

    Stockton, N.B.

    1992-01-01

    This paper examines problems associated with inservice testing (IST) of pumps to assess their hydraulic performance using reference pump curves to establish acceptance criteria. Safety-related pumps at nuclear power plants are tested under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code), Section 11. The Code requires testing pumps at specific reference points of differential pressure or flow rate that can be readily duplicated during subsequent tests. There are many cases where test conditions cannot be duplicated. For some pumps, such as service water or component cooling pumps, the flow rate at any time depends on plant conditions and the arrangement of multiple independent and constantly changing loads. System conditions cannot be controlled to duplicate a specific reference value. In these cases, utilities frequently request to use pump curves for comparison of test data for acceptance. There is no prescribed method for developing a pump reference curve. The methods vary and may yield substantially different results. Some results are conservative when compared to the Code requirements; some are not. The errors associated with different curve testing techniques should be understood and controlled within reasonable bounds. Manufacturer's pump curves, in general, are not sufficiently accurate to use as reference pump curves for IST. Testing using reference curves generated with polynomial least squares fits over limited ranges of pump operation, cubic spline interpolation, or cubic spline least squares fits can provide a measure of pump hydraulic performance that is at least as accurate as the Code required method. Regardless of the test method, error can be reduced by using more accurate instruments, by correcting for systematic errors, by increasing the number of data points, and by taking repetitive measurements at each data point

  3. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  4. The impact of harm reduction programs and police interventions on the number of syringes collected from public spaces. A time series analysis in Barcelona, 2004-2014.

    Science.gov (United States)

    Espelt, A; Villalbí, J R; Bosque-Prous, M; Parés-Badell, O; Mari-Dell'Olmo, M; Brugal, M T

    2017-12-01

    To estimate the effect of opening two services for people who use drugs and three police interventions on the number of discarded syringes collected from public spaces in Barcelona between 2004 and 2014. We conducted an interrupted time-series analysis of the monthly number of syringes collected from public spaces during this period. The dependent variable was the number of syringes collected per month. The main independent variables were month and five dummy variables (the opening of two facilities with safe consumption rooms, and three police interventions). To examine which interventions affected the number of syringes collected, we performed an interrupted time-series analysis using a quasi-Poisson regression model, obtaining relative risks (RR) and 95% confidence intervals (CIs). The number of syringes collected per month in Barcelona decreased from 13,800 in 2004 to 1655 in 2014 after several interventions. For example, following the closure of an open drug scene in District A of the city, we observed a decreasing trend in the number of syringes collected [RR=0.88 (95% CI: 0.82-0.95)], but an increasing trend in the remaining districts [RR=1.11 (95% CI: 1.05-1.17) and 1.08 (95% CI: 0.99-1.18) for districts B and C, respectively]. Following the opening of a harm reduction facility in District C, we observed an initial increase in the number collected in this district [RR=2.72 (95% CI: 1.57-4.71)] and stabilization of the trend thereafter [RR=0.97 (95% CI: 0.91-1.03)]. The overall number of discarded syringes collected from public spaces has decreased consistently in parallel with a combination of police interventions and the opening of harm reduction facilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Single patient doses of {sup 99m}Tc-HDP: Assessment of radiochemical purity, sterility and extractables from a polypropylene syringe over six hours

    Energy Technology Data Exchange (ETDEWEB)

    Parkes, S.L.; Varelis, P. [St George Hospital, Kogarah, NSW (Australia). Department of Nuclear Medicine

    1997-12-01

    Full text: The purpose of this investigation was to determine the radiochemical purity (RCP), sterility and extractables for {sup 99m}Tc oxidronate ({sup 99m}Tc-HDP) stored in polypropylene syringes over < six-hour period. The radiochemical purity was determined using a two-strip ITLC procedure, performed at time 0, 1, 2, 4, 6 hours. The sterility and endotoxin levels were tested by a NATA accredited laboratory, after allowing the radiopharmaceutical to stand at room temperature for six hours in the syringes. Plasticisers and other likely compounds that could be extracted from the syringes into the aqueous solution were determined by high pressure liquid chromatography (HPLC) diode array detection. This analysis involved shaking normal saline in a syringe over night and then injecting an aliquot of this solution onto a C18 analytical column and monitoring the effluent at 200 and 253 nm. The radiochemical purity of {sup 99m}Tc-HDP did not significantly change over the course of the study and remained above the recommended RCP for this radiopharmaceutical. Furthermore, at six hours the RCP of {sup 99m}Tc-HDP stored in both the manufacturer`s vial and a syringe were identical. Sterility testing of {sup 99m}Tc-HDP stored in syringes showed no microbial growth and less than 10 endotoxin units/mL (pass). The HPLC analysis did not show the presence of any extraneous compounds in the aqueous solution. Single patient doses of {sup 99m}Tc-HDP stored in polypropylene syringes over a six-hour period fulfill all the quality control requirements for administration to humans.

  6. Effect of pump limiter throat on pumping efficiency

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-01-01

    The necessary control of plasma edge density has led to the development of pump limiters to achieve this task. On Tore Supra, where a large part of the program is devoted to plasma edge studies, two types of such density control apparatus have been implemented, a set of pump limiters and the pumps associated to the ergodic divertor (magnetically assisted pump limiters). Generally two different kinds of pump limiters can be used, those with a throat which drives the plasma from the open edge plasma (SOL) to the neutralizer plate, and those without or with a very short throat. We are interested here in this aspect of the pump limiter concept, i.e. on the throat effect on neutral density build-up in the vicinity of the pumping plates (and hence on pumping efficieny). The underlying idea of this throat effect can be readily understood; indeed while the neutral capture in pump limiters without throats is only a ballistic effect, on expects the plasma to improve the efficiency of pump-limiters via plasma-neutral-sidewall interactions in the throat. This problem has been studied both numerically and analytically. The paper is divided as follows. In section 2, we describe the basic features of pump-limiters which are modelized by the numerical code Cezanne. Section 3 is devoted to the throat length effect considering in particular the neutral density profile in the throat and the neutral density buil-up as a function of the throat lenght. In section 4, we show that the plugging effect occurs for reasonnable values of throat lengths. An analytical value of the plugging length is discussed and compared to the values obtained numerically

  7. Replacement of the Pumps for Fuel Channel Cooling Circuit of the Maria Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Krzysztoszek, G.; Mieleszczenko, W.; Moldysz, A. [National Centre for Nuclear Research, Otwock–Świerk (Poland)

    2014-08-15

    The high flux Maria research reactor is operated by the National Centre for Nuclear Research in Świerk. It is a pool type reactor with pressurized fuel channels located in the beryllium matrix. According to the Global Threat Reduction Initiative programme our goal is to convert the Maria reactor from HEU to LEU fuel. Hydraulic losses in the new LEU fuel produced by CERCA are about 30% higher than the existing HEU fuel of type MR-6. For the MR-6 fuel were installed four two speed pumps. These pumps performed the function of the main circulations pumps during reactor operation with residual pumping power provided by emergency pumps. In the new system four main pumps will be used for circulating coolant while the reactor is operation with three auxiliary pumps for decay heat removal after reactor shutdown, meaning that the conversion of Maria research reactor will be possible after increasing flow in the primary cooling circuit of the fuel channels. The technical design of replacement of the pumps in the primary fuel channel cooling circuit was finished in April 2011 and accepted by the Safety Committee. After delivery of the new pumps we are planning to upgrade the primary fuel channel cooling circuit during October–November 2012. (author)

  8. Mechanical pumping at low temperature

    International Nuclear Information System (INIS)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1995-01-01

    This novel concept consist of a mechanical pump able to run at low temperature (25K). Since gas density varies inversely with temperature, this pump would deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are order of magnitude reduction in size, weight, when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. This pump would be a solution to allow continuously tritium extraction and minimize the mass inventory. (orig.)

  9. Proper Sizing of Circulation Pumps

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Nørgaard, Jørgen

    2007-01-01

    The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust, but the r......The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust...

  10. High-vacuum plasma pump

    International Nuclear Information System (INIS)

    Dorodnov, A.M.; Minajchev, V.E.; Miroshkin, S.I.

    1980-01-01

    The action of an electric-arc high-vacuum pump intended for evacuating the volumes in which the operation processes are followed by a high gas evolution is considered. The operation of the pump is based on the principle of controlling the getter feed according to the gas load and effect of plasma sorbtion pumping. The pump performances are given. The starting pressure is about 5 Pa, the limiting residual pressure is about 5x10 -6 Pa, the pumping out rate of nitrogen in the pressure range 5x10 -5 -5x10 -3 Pa accounts for about 4000 l/s, the power consumption comes to 6 kW. Analyzing the results of the test operation of the pump, it has been concluded that its principal advantages are the high starting pressure, controlled getter feed rate and possibility of pumping out the gases which are usually pumped out with difficulty. The operation reliability of the pump is defined mainly by reliable operation of the ignition system of the vacuum arc [ru

  11. Mono pump equipment evaluation report

    International Nuclear Information System (INIS)

    1992-01-01

    A mobile pump has been designed, developed, and tested as part of an effort to increase oil spill response time, improve oil/water recovery efficiency and reduce cleanup and reclamation costs. The pump is mounted on an engine powered track carrier, and can be detached from the carrier and skidded into remote spill sites or transported by helicopter. The pump can safely recover highly volatile flammable substances such as condensate and gasoline, as well as heavy crude oil up to 5000 centipoise viscosity. It can pump up to 30 gal/min at zero head, and up to 1000 feet in a vertical direction. 13 figs

  12. Fusion technology programme

    International Nuclear Information System (INIS)

    Finken, D.

    1984-04-01

    KfK participates to the Fusion Technology Programme of the European Community. Most of the work in progress addresses the Next European Torus (NET) and the long term technology aspects as defined in the 82/86 programme. A minor part serves to preparation of future contributions and to design studies on fusion concepts in a wider perspective. The Fusion Technology Programme of Euratom covers mainly aspects of nuclear engineering. Plasma engineering, heating, refueling and vacuum technology are at present part of the Physics Programme. In view of NET, integration of the different areas of work will be mandatory. KfK is therefore prepared to address technical aspects beyond the actual scope of the physics experiments. The technology tasks are reported project wise under title and code of the Euratom programme. Most of the projects described here are shared with other European fusion laboratories as indicated in the table annexed to this report. (orig./GG)

  13. Resonant Tunneling Spin Pump

    Science.gov (United States)

    Ting, David Z.

    2007-01-01

    The resonant tunneling spin pump is a proposed semiconductor device that would generate spin-polarized electron currents. The resonant tunneling spin pump would be a purely electrical device in the sense that it would not contain any magnetic material and would not rely on an applied magnetic field. Also, unlike prior sources of spin-polarized electron currents, the proposed device would not depend on a source of circularly polarized light. The proposed semiconductor electron-spin filters would exploit the Rashba effect, which can induce energy splitting in what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. Theoretical studies have suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling.

  14. Heat pump system with selective space cooling

    Science.gov (United States)

    Pendergrass, J.C.

    1997-05-13

    A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve. 4 figs.

  15. Survey of pumps for tritium gas

    International Nuclear Information System (INIS)

    Dowell, T.M.

    1983-05-01

    This report considers many different types of pumps for their possible use in pumping tritium gas in the low, intermediate and high vacuum ranges. No one type of pump is suitable for use over the wide range of pumping pressure required in a typical pumping system. The favoured components for such a system are: bellows pump (low vacuum); orbiting scroll pump (intermediate vacuum); magnetically suspended turbomolecular pump (high vacuum); cryopump (high vacuum). Other pumps which should be considered for possible future development are: mound modified vane pump; SRTI wobble pump; roots pump with canned motor. It is proposed that a study be made of a future tritium pumping system in a Canadian tritium facility, e.g. a tritium laboratory

  16. LMR [liquid metal reactor] centrifugal pump coastdowns

    International Nuclear Information System (INIS)

    Dunn, F.E.; Malloy, D.J.

    1987-01-01

    A centrifugal pump model which describes the interrelationships of the pump discharge flowrate, pump speed, shaft torque and dynamic head has been implemented based upon existing models. Specifically, the pump model is based upon the dimensionless-homologous pump theory of Wylie and Streeter. Given data from a representative pump, homologous theory allows one to predict the transient characteristics of similarly sized pumps. This homologous pump model has been implemented into both the one-dimensional SASSYS-1 systems analysis code and the three-dimensional COMMIX-1A code. Comparisons have been made both against other pump models (CRBR) and actual pump coastdown data (EBR-II and FFTF). Agreement with this homologous pump model has been excellent. Additionally, these comparisons indicate the validity of applying the medium size pump data of Wylie and Streeter to a range of typical LMR centrifugal pumps

  17. Work plan, AP-102 mixer pump removal and pump replacement

    International Nuclear Information System (INIS)

    Jimenez, R.F.

    1994-01-01

    The objective of this work plan is to plan the steps and estimate the costs required to remove the failed AP-102 mixer pump, and to plan and estimate the cost of the necessary design and specification work required to order a new, but modified, mixer pump including the pump and pump pit energy absorbing design. The main hardware required for the removal of the mixer is as follows: a flexible receiver and blast shield; a metal container for the pulled mixer pump; and a trailer and strongback to haul and manipulate the container. Additionally: a gamma scanning device will be needed to detect the radioactivity emanating from the mixer as it is pulled from the tank; a water spray system will be required to remove tank waste from the surface of the mixer as it is pulled from the AP-102 tank; and a lifting yoke to lift the mixer from the pump pit (the SY-101 Mixer Lifting Yoke will be used). A ''green house'' will have to be erected over the AP-102 pump pit and an experienced Hoisting and Rigging crew must be assembled and trained in mixer pump removal methods before the actual removal is undertaken

  18. Diode-pumped laser with improved pumping system

    Science.gov (United States)

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  19. Stability of Hydromorphone-Ketamine Solutions in Glass Bottles, Plastic Syringes, and IV Bags for Pediatric Use.

    Science.gov (United States)

    Ensom, Mary H H; Decarie, Diane; Leung, Karen; Montgomery, Carolyne

    2009-03-01

    To evaluate the stability of mixtures of hydromorphone and ketamine in 0.9% sodium chloride (normal saline [NS]) after storage for up to 7 days at room temperature (25°C). The stability of 3 standard mixtures of hydromorphone and ketamine (hydromorphone 0.2 mg/mL + ketamine 0.2 mg/mL, hydromorphone 0.2 mg/mL + ketamine 0.6 mg/mL, and hydromorphone 0.2 mg/mL + ketamine 1.0 mg/mL) in NS was studied. Portions of each mixture were transferred to 3 brown glass bottles (100 mL), 3 plastic syringes (50 mL), and 3 IV bags (50 mL), which were then stored at room temperature (25°C). Physical characteristics, including pH, colour, and precipitation, were evaluated daily. Three 1.5-mL samples were collected from each bottle, syringe, and IV bag at baseline, at 24, 48, and 72 hours, and on day 7. Samples were analyzed in triplicate by a stability-indicating high-performance liquid chromatography method. Solutions were considered stable if they maintained 90% of the initial concentration of each drug. Samples from syringes and IV bags were subjected to standard sterility testing by incubation for 5 days in an enriched culture media. No notable changes in pH or colour were observed, and no precipitation occurred in any of the solutions. All formulations maintained more than 90% of the initial concentration of each drug on day 7. No bacterial growth was observed in any of the samples tested. Mixtures of hydromorphone and ketamine were stable for up 7 days at 25°C, and the sterility of the preparations was maintained. Because stability alone does not guarantee efficacy, it is recommended that clinical studies be conducted to evaluate the pharmacokinetics and pharmacodynamics of these formulations.

  20. Stability of sodium bicarbonate injection 8.4% in syringes over a six-week period in refrigerated temperature.

    Science.gov (United States)

    Seki, Jack T; Wang, Tian Q; Yip, Paul M; Mazzulli, Tony; Minden, Mark D

    2018-04-01

    Background Dysfunctional central venous catheter prohibits the administration of potential life-saving chemotherapy and the delivery of essential supportive care needs to patients. Sodium bicarbonate injection has been shown to impede against fibrin clot formation and prolong prothrombin time and thrombin clotting time. Sodium bicarbonate injection has been tried as a second-line agent with good results in a small number of patients (internal data not published) when alteplase failed. We assessed whether the pre-filled sodium bicarbonate injection in 5 mL syringes would not only preserve sterility and retain its pH and concentration but also amount to the potential cost savings for future use when stored in a refrigerated environment. Methodology Twelve pre-filled 5 mL syringes were prepared aseptically, of which four each were tested for pH, sodium bicarbonate injection concentration and sterility when stored in refrigerated temperature over a six-week period. A standard pH meter, enzymatic carbon dioxide analyzer, and a 14-day incubation for microbial detection were employed for this study. Results Sodium bicarbonate concentration measured in the form of carbon dioxide ranged from 923 mmol/L or (1846 mosol/L) to 1006 mmol/L or (2012 mosmol/L), and pH ranged from (7.88 to 8.05) were reported over the duration of the study period. The 14-day incubation period resulted in no microbial growth. Conclusion Our study results have indicated that the pH and sodium bicarbonate injection concentration values were stable and within range, comparable to those reported by the manufacturer within the study period. The contents of the subdivided sodium bicarbonate injection 5 mL syringes retained sterility over a 14-day incubation period.

  1. Pumps in wearable ultrafiltration devices: pumps in wuf devices.

    Science.gov (United States)

    Armignacco, Paolo; Garzotto, Francesco; Bellini, Corrado; Neri, Mauro; Lorenzin, Anna; Sartori, Marco; Ronco, Claudio

    2015-01-01

    The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features. © 2015 S. Karger AG, Basel.

  2. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  3. 46 CFR 119.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge pumps. 119.520 Section 119.520 Shipping COAST... Ballast Systems § 119.520 Bilge pumps. (a) Each vessel must be provided with bilge pumps in accordance... have a portable hand bilge pump that must be: (1) Capable of pumping water, but not necessarily...

  4. 46 CFR 154.1135 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pumps. 154.1135 Section 154.1135 Shipping COAST GUARD... Pumps. (a) Water to the water spray system must be supplied by: (1) A pump that is only for the use of the system; (2) A fire pump; or (3) A pump specially approved by the Commandant (CG-522). (b...

  5. 33 CFR 157.126 - Pumps.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Pumps. 157.126 Section 157.126... Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.126 Pumps. (a) Crude oil must be supplied to the COW machines by COW system pumps or cargo pumps. (b) The pumps under paragraph...

  6. Issues and prospects vis a vis Indian PV commercialization programme

    International Nuclear Information System (INIS)

    Deambi, Suneel

    1994-01-01

    Following a large scale demonstration of photovoltaic systems attending to the important requirements of lighting, water pumping, television and battery charging etc. in the remote surroundings of India, serious efforts are being made to promote the commercial use of these systems. A recently launched World Bank-supported project on PV market development has provided the much needed boost to the Indian PV programme. This paper tries to analyse the issues and prospects with respect to the National PV Commercialization Programme in view of the changing PV scenario in the country. (author)

  7. Multiple access to sterile syringes for injection drug users: vending machines, needle exchange programs and legal pharmacy sales in Marseille, France.

    Science.gov (United States)

    Moatti, J P; Vlahov, D; Feroni, I; Perrin, V; Obadia, Y

    2001-03-01

    In Marseille, southeastern France, HIV prevention programs for injection drug users (IDUs) simultaneously include access to sterile syringes through needle exchange programs (NEPs), legal pharmacy sales and, since 1996, vending machines that mechanically exchange new syringes for used ones. The purpose of this study was to compare the characteristics of IDUs according to the site where they last obtained new syringes. During 3 days in September 1997, all IDUs who obtained syringes from 32 pharmacies, four NEPs and three vending machines were offered the opportunity to complete a self-administered questionnaire on demographics, drug use characteristics and program utilization. Of 485 individuals approached, the number who completed the questionnaire was 141 in pharmacies, 114 in NEPs and 88 at vending machines (response rate = 70.7%). Compared to NEP users, vending machine users were younger and less likely to be enrolled in a methadone program or to report being HIV infected, but more likely to misuse buprenorphine. They also had lower financial resources and were less likely to be heroin injectors than both pharmacy and NEP users. Our results suggest that vending machines attract a very different group of IDUs than NEPs, and that both programs are useful adjuncts to legal pharmacy sales for covering the needs of IDUs for sterile syringes in a single city. Assessment of the effectiveness and cost-effectiveness of combining such programs for the prevention of HIV and other infectious diseases among IDUs requires further comparative research. Copyright 2001 S. Karger AG, Basel

  8. Low flow measurement for infusion pumps: implementation and uncertainty determination of the normalized method

    International Nuclear Information System (INIS)

    Cebeiro, J; Musacchio, A; Sardá, E Fernández

    2011-01-01

    Intravenous drug delivery is a standard practice in hospitalized patients. As the blood concentration reached depends directly on infusion rate, it is important to use safe devices that guarantee output accuracy. In pediatric intensive care units, low infusion rates (i.e. lower than 10.0 ml/h) are frequently used. Thus, it would be necessary to use control programs to search for deviations at this flow range. We describe the implementation of a gravimetric method to test infusion pumps in low flow delivery. The procedure recommended by the ISO/IEC 60601-2-24 standard was used being a reasonable option among the methods frequently used in hospitals, such as infusion pumps analyzers and volumetric cylinders. The main uncertainty sources affecting this method are revised and a numeric and graphic uncertainty analysis is presented in order to show its dependence on flow. Additionally, the obtained uncertainties are compared to those presented by an automatic flow analyzer. Finally, the results of a series of tests performed on a syringe infusion pump operating at low rates are shown.

  9. Summarized results of the cryosorption panel test programme for the ITER cryopumping system

    International Nuclear Information System (INIS)

    Day, C.; Haas, H.; Mack, A.; Kazakovsky, N.T.; Murdoch, D.K.; Roehrig, D.; Saksagansky, G.L.

    2001-01-01

    A reliable but versatile primary cryopumping system is required for high vacuum pumping of the ITER torus during all phases of plasma operation. To achieve that goal, an extensive R and D programme has been performed within the framework of the Nuclear Fusion Project of FZK, supported by the European Communities under the European Fusion Technology Programme. The present paper covers that part of the programme, which focuses on the pumping speed of the recommended cryopanel type and the various aspects of the charcoal-bonding system in the cryogenic temperature range. It is demonstrated that the investigated cryosorption panels exhibit a very good behaviour with respect to pumping efficiency, long-term thermomechanical endurance and compatibility with tritium. The recommended cryopump design was therefore chosen as point design for ITER. (author)

  10. Simultaneous extraction and determination of albendazole and triclabendazole by a novel syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop combined with high performance liquid chromatography.

    Science.gov (United States)

    Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad

    2016-08-17

    A syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was introduced and used for the simultaneous extraction of trace amounts of albendazole and triclabendazole from different matrices. The extracted analytes were determined by high performance liquid chromatography along with fluorescence detection. The analytical parameters affecting the microextraction efficiency including the nature and volume of the extraction solvent, sample volume, sample pH, ionic strength and the cycles of extraction were optimized. The calibration curves were linear in the range of 0.1-30.0 μg L(-1) and 0.2-30.0 μg L(-1) with determination coefficients of 0.9999 and 0.9998 for albendazole and triclabendazole respectively. The detection limits defined as three folds of the signal to noise ratio were found to be 0.02 μg L(-1) for albendazole and 0.06 μg L(-1) for triclabendazole. The inter-day and intra-day precision (RSD%) for both analytes at three concentration levels (0.5, 2.0 and 10.0 μg L(-1)) were in the range of 6.3-10.1% and 5.0-7.5% respectively. The developed method was successfully applied to determine albendazole and triclabendazole in water, cow milk, honey, and urine samples. Copyright © 2016. Published by Elsevier B.V.

  11. High temperature thermoacoustic heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [Energy research Centre of the Netherlands, 1755 ZG Petten (Netherlands)

    2012-06-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. A thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestics and offices energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6% and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  12. Review of magnetohydrodynamic pump applications

    Directory of Open Access Journals (Sweden)

    O.M. Al-Habahbeh

    2016-06-01

    Full Text Available Magneto-hydrodynamic (MHD principle is an important interdisciplinary field. One of the most important applications of this effect is pumping of materials that are hard to pump using conventional pumps. In this work, the progress achieved in this field is surveyed and organized according to the type of application. The literature of the past 27 years is searched for the major developments of MHD applications. MHD seawater thrusters are promising for a variety of applications requiring high flow rates and velocity. MHD molten metal pump is important replacement to conventional pumps because their moving parts cannot stand the molten metal temperature. MHD molten salt pump is used for nuclear reactor coolants due to its no-moving-parts feature. Nanofluid MHD pumping is a promising technology especially for bioapplications. Advantages of MHD include silence due to no-moving-parts propulsion. Much progress has been made, but with MHD pump still not suitable for wider applications, this remains a fertile area for future research.

  13. Direct solar-pumped lasers

    Science.gov (United States)

    Lee, J. H.; Shiu, Y. J.; Weaver, W. R.

    1980-01-01

    The feasibility of direct solar pumping of an iodine photodissociation laser at lambda = 1.315 microns was investigated. Threshold inversion density and effect of elevated temperature (up to 670 K) on the laser output were measured. These results and the concentration of solar radiation required for the solar pumped iodine laser are discussed.

  14. Heat pumping in nanomechanical systems.

    Science.gov (United States)

    Chamon, Claudio; Mucciolo, Eduardo R; Arrachea, Liliana; Capaz, Rodrigo B

    2011-04-01

    We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve. © 2011 American Physical Society

  15. Heat pumping in nanomechanical systems

    OpenAIRE

    Chamon, Claudio; Mucciolo, Eduardo R.; Arrachea, Liliana; Capaz, Rodrigo B.

    2010-01-01

    We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve.

  16. High Temperature Thermoacoustic Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-07-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. Thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestic and office energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6 % and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  17. Reflection of centrifugal pumps maintenance

    International Nuclear Information System (INIS)

    Mozos Fernandez, V.

    2010-01-01

    The aim of this work is to prove that is not necessary a deep and complex knowledge to manage the centrifugal pumps maintenance. According to the author, only deep but single technical knowledge about causes of breakdowns in the different and simple component parts of the pumps, are required. (Author)

  18. The Plasma Membrane Calcium Pump

    Science.gov (United States)

    Rasmussen, H.

    1983-01-01

    Three aspect of cellular calcium metabolism in animal cells was discussed including the importance of the plasma membrane in calcium homeostasis, experiments dealing with the actual mechanism of the calcium pump, and the function of the pump in relationship to the mitochondria and to the function of calmodulin in the intact cell.

  19. Optical programmable metamaterials

    Science.gov (United States)

    Gong, Cheng; Zhang, Nan; Dai, Zijie; Liu, Weiwei

    2018-02-01

    We suggest and demonstrate the concept of optical programmable metamaterials which can configure the device's electromagnetic parameters by the programmable optical stimuli. In such metamaterials, the optical stimuli produced by a FPGA controlled light emitting diode array can switch or combine the resonance modes which are coupled in. As an example, an optical programmable metamaterial terahertz absorber is proposed. Each cell of the absorber integrates four meta-rings (asymmetric 1/4 rings) with photo-resistors connecting the critical gaps. The principle and design of the metamaterials are illustrated and the simulation results demonstrate the functionalities for programming the metamaterial absorber to change its bandwidth and resonance frequency.

  20. NNP Life Management Programmes

    International Nuclear Information System (INIS)

    Hervia Ruperez, F.

    1996-01-01

    Around the world, power station owners are increasingly concerned to optimise Plant Life Management. In response, they are setting up Life Management programmes, of more or less ambitious scope and depth. Strategic, economic and security concerns and the close link between life extension work and the improved maintenance practices that are so important today, will increase and global these programmes for monitoring and conservation or mitigation of ageing. These programmes are all based on knowledge of the precise condition of all components and population with the greatest effect on the economics and safety of the plant, and trends in changes in their condition. (Author)

  1. The European Fusion Programme

    International Nuclear Information System (INIS)

    Palumbo, D.

    1983-01-01

    The European Fusion Programme is coordinated by Euratom and represents a long term cooperative project of Member States of the European Communities in the field of fusion, designed to lead to the joint construction of prototypes. The main lines of the programme proposed for 1982 to 1986 are: (1) the continuation of a strong effort on tokamaks with emphasis on JET construction, operation and upgrading, (2) conceptual design of NET and development of the related technology, and (3) further work on two alternative magnetic confinement systems. The current status and future plans for this programme are discussed in the paper. (author)

  2. Self pumping magnetic cooling

    International Nuclear Information System (INIS)

    Chaudhary, V; Wang, Z; Ray, A; Ramanujan, R V; Sridhar, I

    2017-01-01

    Efficient thermal management and heat recovery devices are of high technological significance for innovative energy conservation solutions. We describe a study of a self-pumping magnetic cooling device, which does not require external energy input, employing Mn–Zn ferrite nanoparticles suspended in water. The device performance depends strongly on magnetic field strength, nanoparticle content in the fluid and heat load temperature. Cooling (Δ T ) by ∼20 °C and ∼28 °C was achieved by the application of 0.3 T magnetic field when the initial temperature of the heat load was 64 °C and 87 °C, respectively. These experiments results were in good agreement with simulations performed with COMSOL Multiphysics. Our system is a self-regulating device; as the heat load increases, the magnetization of the ferrofluid decreases; leading to an increase in the fluid velocity and consequently, faster heat transfer from the heat source to the heat sink. (letter)

  3. Electric Turbo Pump

    Science.gov (United States)

    Steckler, Jessica

    2017-01-01

    NASA is working in junction with another company on the Electric Turbo Pump. Analysis of the impeller, including the blades, volute housing, and associated components, will take place in ANSYS. Contours of the deformed and stress were recorded to assess the parts. Campbell diagrams will be considered as mentioned to find the operating regions of the impeller and volute housing, more specifically what speed is ideal to ensure that the impeller does not begin to vibrate at a frequency that will break it. More than one material will be examined as per request by the designer to determine which material is more cost efficient, easy to machine, and can withstand the stress values that will be placed on it.

  4. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  5. Dual source heat pump

    Science.gov (United States)

    Ecker, Amir L.; Pietsch, Joseph A.

    1982-01-01

    What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid provides energy for defrosting the second heat exchanger when operating in the air source mode and also provides a alternate source of heat.

  6. High temperature industrial heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Berghmans, J. (Louvain Univ., Heverlee (Belgium). Inst. Mechanica)

    1990-01-01

    The present report intends to describe the state of the art of high temperature industrial heat pumps. A description is given of present systems on the market. In addition the research and development efforts on this subject are described. Compression (open as well as closed cycle) systems, as well as absorption heat pumps (including transformers), are considered. This state of the art description is based upon literature studies performed by a team of researchers from the Katholieke Universiteit Leuven, Belgium. The research team also analysed the economics of heat pumps of different types under the present economic conditions. The heat pumps are compared with conventional heating systems. This analysis was performed in order to evaluate the present condition of the heat pump in the European industry.

  7. Status of sodium boiling noise detection programme at reactor research centre, India

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakar, R; Elumalai, G [Reactor Engineering Laboratory, Reactor Research Centre, Chingleput, Tamil Nadu (India)

    1982-01-01

    Acoustic detection of sodium boiling is a promising technique to monitor subassembly fault in a last reactor. This paper summarises the programme for developing this detection system and describes the design of a high temperature transducer for boiling detection. It is appreciated that the background noise from primary pumps can interfere with this detection. Noise measurements were therefore carried out during water testing of the primary pump of the Fast Breeder Test Reactor. Some preliminary results of these measurements are presented.

  8. Status of sodium boiling noise detection programme at reactor research centre, India

    International Nuclear Information System (INIS)

    Prabhakar, R.; Elumalai, G.

    1982-01-01

    Acoustic detection of sodium boiling is a promising technique to monitor subassembly fault in a last reactor. This paper summarises the programme for developing this detection system and describes the design of a high temperature transducer for boiling detection. It is appreciated that the background noise from primary pumps can interfere with this detection. Noise measurements were therefore carried out during water testing of the primary pump of the Fast Breeder Test Reactor. Some preliminary results of these measurements are presented

  9. Fellows, Associates & Students Programmes

    CERN Document Server

    2005-01-01

    The present document reviews the CERN Fellows, Associates and Students Programmes emphasizing the developments since 2000, when the previous review was presented to the Scientific Policy Committee, Finance Committee and Council (CERN/2325), and makes proposals for the coming five years. In summary, it is proposed to â?¢ Simplify the payment scheme for the Paid Scientific Associates Programme, which will no longer depend on candidateâ??s home support and age; â?¢ Broaden the scope of the Fellowship Programme, in order to facilitate the recruitment of young graduates in computing and engineering. Age-related eligibility conditions and payment levels will be replaced with experience-based criteria; â?¢ Modify subsistence rates for the Doctoral and Technical Student Programme in order to harmonize CERNâ??s payment levels with those offered by other research establishments. This document is presented for discussion and recommendation by the Scientific Policy Committee and approval by the Council. Additiona...

  10. (ARV) treatment training programme

    African Journals Online (AJOL)

    Winnie

    Keywords:ARV, training, evaluation, HIV, health care provider. RÉSUMÉ .... workers, adequate laboratory facilities for measuring viral load and .... questionnaire guide, the head of unit of the ART ...... begins its scale-up programme. Some of ...

  11. The French nuclear programme

    International Nuclear Information System (INIS)

    Bacher, Pierre

    1987-01-01

    France has a civil nuclear power generation programme second only to the USA with 49 nuclear units in operation and 13 under construction. The units in service are described. These include 33 PWR 900 MW and 9 PWR 1300 MW units. The electricity consumption and generation in France is illustrated. The absence of a powerful anti-nuclear lobby and two main technical options have contributed to the success of the French nuclear programme. These are the PWR design and the plant standardization policy which allows the setting up of an effective industrial complex (eg for analysis of operating conditions and of safety and reliability information). The programme and the reasons for its success are reviewed. Research programmes and future plans are also discussed. (UK)

  12. Elukestva õppe programm : Erasmus+

    Index Scriptorium Estoniae

    2014-01-01

    Erasmus+ programm liidab senised koostööprogrammid „Euroopa elukestva õppe programm“, „Euroopa Noored“ ning Euroopa komisjoni rahvusvahelised kõrgharidusprogrammid. Elukestva õppe programmi 2013 kokkuvõte

  13. Greek Teachers Programme 2015

    CERN Multimedia

    Hoch, Michael

    2015-01-01

    The 3rd edition of this year's Greek Teachers Programme was co-organized by CERN Education Group and the Hellenic Physical Society and took place from 8 to 12 November 2015. The programme targets physics high-school teachers from all over Greece. It aims to help teachers inspire the next generation of scientists and engineers by motivating their students to understand and appreciate how science works at the world's largest physics laboratory, whereby increasing their interest in pursuing studies in STEM fields in secondary and post-secondary education. 33 teachers took part in this programme which comprised lectures by Greek members of the CERN scientific community, with visits to experimental facilities, hands-on activities and dedicated sessions on effective and creative ways through which participants may bring physics, particle physics and CERN closer to their school classroom. In 2015, more than 100 teachers took part in the three editions of the Greek Teachers Programme.

  14. The French energy programme

    International Nuclear Information System (INIS)

    Bohnen, U.

    1980-01-01

    The challenge of the oil crisis made French energy policy react chiefly by means of a programme for the rapid expansion of nuclear energy which has become unparalleled because of its systematic realization. The following article gives a survey of this programme and its political preconditions. The French energy programme deserves special attention as the utilization of nuclear energy in France including all related activities has reached a more advanced stage than in most other countries. The effects and requirements connected with such an extensive programme which can therefore be investigated with the help of the French example migth be of importance also for other countries in a similar way. (orig./UA) [de

  15. Effect of liposomes on rheological and syringeability properties of hyaluronic acid hydrogels intended for local injection of drugs.

    Science.gov (United States)

    El Kechai, Naila; Bochot, Amélie; Huang, Nicolas; Nguyen, Yann; Ferrary, Evelyne; Agnely, Florence

    2015-06-20

    The aim of this work was to thoroughly study the effect of liposomes on the rheological and the syringeability properties of hyaluronic acid (HA) hydrogels intended for the local administration of drugs by injection. Whatever the characteristics of the liposomes added (neutral, positively or negatively charged, with a corona of polyethylene glycol chains, size), the viscosity and the elasticity of HA gels increased in a lipid concentration-dependent manner. Indeed, liposomes strengthened the network formed by HA chains due to their interactions with this polymer. The nature and the resulting effects of these interactions depended on liposome composition and concentration. The highest viscosity and elasticity were observed with liposomes covered by polyethylene glycol chains while neutral liposomes displayed the lowest effect. Despite their high viscosity at rest, all the formulations remained easily injectable through needles commonly used for local injections thanks to the shear-thinning behavior of HA gels. The present study demonstrates that rheological and syringeability tests are both necessary to elucidate the behavior of such systems during and post injection. In conclusion, HA liposomal gels appear to be a promising and versatile formulation platform for a wide range of applications in local drug delivery when an injection is required. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. In-syringe dispersive liquid-liquid microextraction with liquid chromatographic determination of synthetic pyrethroids in surface water

    Directory of Open Access Journals (Sweden)

    Saeed S. Albaseer

    2012-03-01

    Full Text Available An indigenously fabricated in laboratory glass syringe was used for in-syringe dispersive liquid-liquid microextraction (is-DLLME and preconcentration of synthetic pyrethroids (SPs from surface waters suitable for their determination by high performance liquid chromatography. In contrast to classical DLLME, is-DLLME allows the use of lighter-than-water organic solvents and the analysis of environmental contaminants’ samples without prior filtration, which is of great importance due to the high affinity of pyrethroids to adsorb to solid particulates present in environmental samples. The effects of various parameters on the extraction efficiency were evaluated and optimized systemically using one-factor-at-a-time method (OFAT and statistically using full factorial design (24. Three SPs (viz.; cypermethrin, resmethrin and permethrin were analyzed. The method showed good accuracy with RSD% in the range of of 4.8–6.9%. The method detection limits of the three pesticides ranged from 0.14 to 0.16 ng mL-1. The proposed method was applied for the determination of synthetic pyrethroids in lake water

  17. Extraction of mandibular premolars and molars: comparison between local infiltration via pressure syringe and inferior alveolar nerve block anesthesia.

    Science.gov (United States)

    Thiem, Daniel G E; Schnaith, Florian; Van Aken, Caroline M E; Köntges, Anne; Kumar, Vinay V; Al-Nawas, Bilal; Kämmerer, Peer W

    2018-04-01

    The purpose of this study was to evaluate the anesthetic efficiency of local infiltration anesthesia administered with a pressure syringe (P-INF) via a special technique versus direct block anesthesia of the inferior alveolar nerve (IANB) for tooth extraction in the posterior mandible. In a prospective randomized study, 101 teeth in 101 patients were extracted in the posterior mandible under local anesthesia whereby two different administration techniques were used (P-INF n = 48; IANB n = 53). Primary objectives were comparisons of anesthetic success rate (yes/no) and efficacy (full/sufficient vs. insufficient). Secondary objectives were patients' pain perception during treatment, pain of injection (numerical rating scale), need for second injections (always IANB), time until onset of anesthetic action (min), and duration of local numbness (min). IANB was successful in all cases, whereas initial P-INF achieved 35% of success only. Furthermore, IANB reached significant higher values of anesthetic efficacy compared to P-INF (P block anesthesia of the inferior alveolar nerve (IANB) turned out to be more proficient to local infiltration via special delivering system with a special technique. Infiltration, even when performed with 4% articaine and a pressure syringe system, is not a suitable method of anesthesia in the posterior mandible.

  18. Stability of Fentanyl Citrate, Hydromorphone Hydrochloride, Ketamine Hydrochloride, Midazolam, Morphine Sulfate, and Pentobarbital Sodium in Polypropylene Syringes.

    Science.gov (United States)

    Anderson, Collin; MacKay, Mark

    2015-12-16

    Determine the stability of fentanyl 10 mcg/mL in 0.9% sodium chloride, fentanyl 10 mcg/mL in 5% dextrose, fentanyl 50 mcg/mL, hydromorphone 100 mcg/mL in 0.9% sodium chloride, ketamine 10 mg/mL, midazolam 0.4 mg/mL in 5% dextrose, midazolam 5 mg/mL, morphine 1 mg/mL in 0.9% sodium chloride, morphine 1 mg/mL in 5% dextrose, and pentobarbital 50 mg/mL when stored as single drug entities at room temperature in polypropylene syringes. Four 5 mL samples of each drug and concentration were prepared in 10 mL polypropylene syringes. The samples were stored at ambient room temperature in a locked cabinet. Triplicate determinations of drug concentration for each sample were performed initially, on day 50 or 51, and on day 100 using high-performance liquid chromatography with diode-array detection. With the exception of the hydromorphone 100 mcg/mL dilution, all compounds were found to contain greater than 95% of their initial concentration remaining at 100 days. Each sample remained clear and colorless when visually inspected.

  19. The Gold Standard Programme

    DEFF Research Database (Denmark)

    Neumann, Tim; Rasmussen, Mette; Ghith, Nermin

    2013-01-01

    To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates.......To evaluate the real-life effect of an evidence-based Gold Standard Programme (GSP) for smoking cessation interventions in disadvantaged patients and to identify modifiable factors that consistently produce the highest abstinence rates....

  20. Motivation programmes of organizations

    OpenAIRE

    Pízová, Tereza

    2008-01-01

    The Bachelor Thesis "'Motivation Programmes of Organizations" focuses on an extremely important area within personnel management. Employee motivation is crucial to the effective operation of businesses. Motivation programmes assist in increasing and maintaining employee motivation and demonstrate an organization's interest in its employees. This piece is on one hand concerned with theoretical foundations of motivation, describing theories and concepts important to the area of human behaviour ...

  1. Pumping characteristics of sputter ion pump (SIP) and titanium sublimation pump (TSP) combination

    International Nuclear Information System (INIS)

    Ratnakala, K.C.; Patel, R.J.; Bhavsar, S.T.; Pandiyar, M.L.; Ramamurthi, S.S.

    1995-01-01

    For achieving hydrocarbon free, clean ultra high vacuum, SIP-TSP combination is one of the ideal choice for pumping. For the SRS facility in Centre for Advanced Technology (CAT), we are utilising this combination, enmass. For this purpose, two modules of these combination set-ups are assembled, one with the TSP as an integral part of SIP and the other, with TSP as a separate pump mounted on the top of SIP. The pump bodies were vacuum degassed at 700 degC at 10 -5 mbar for 3 hrs. An ultimate vacuum of 3 x 10 -11 mbar was achieved, after a bake-out at 250 degC for 4 hrs, followed by continuous SIP pumping for 48 hrs, with two TSP flashing at approximately 10 hrs interval. The pump-down patterns as well as the pressure-rise patterns are studied. (author). 2 refs., 5 figs

  2. [2000-year history of the ear syringe and its relationship to the enema. Images from the history of otorhinolaryngology, represented by instruments from the collection of the Ingolstadt Medical History Museum].

    Science.gov (United States)

    Feldmann, H

    1999-08-01

    SYRINGES WITH A PISTON AND THEIR USE AS "CLYSTER ORICULARIUS" IN THE ANCIENT ROME: Syringes with a piston were already known in ancient times and have been mentioned as a device for spraying rose water (Philon of Byzantium, about 230 BC), and for fighting fires (Heron of Alexandria about 110 AD). Celsus mentions it several times in his grand opus "De Medicina" (1st century AD) in the treatment of purulent discharge from the ear and for removing foreign bodies from the external ear canal. He always calls it "clyster oricularius", i.e. ear syringe, even when he describes its use in applications other than otological, such as in urology. Later the ear syringe fell from favor for a very long time and was reinvented only at the beginning of the 19th century. IRRIGATION OF THE BOWELS, FROM THE BAG SYRINGE TO THE PISTON SYRINGE: Irrigations of the bowels, clysters, were performed from ancient times to the 18th century with a baglike syringe using the bladder of animals as a pouch. Syringes with a piston were used by barbers and surgeons only for cleansing wounds or irrigating natural cavities of the body. Irrigation of the external ear canal had completely fallen from favor. In France in the 18th century large syringes with a piston made of tin oder brass came into use for enemas and replaced the old baglike devices. THE REINVENTION OF THE EAR SYRINGE AFTER THE PROTOTYPE OF THE ENEMA SYRINGE: Itard, an otologist in France in 1821, was the first to describe irrigating the ear with a syringe to remove hard wax. He recommended using an enema syringe ("seringue à lavement") for the procedure. Soon after his publication special ear syringes of appropriate size were developed and described by Beck in Freiburg, Germany, in 1827; by Fabrizi in Modena, Italy, 1839; and Schmalz in Dresden, Germany, 1846, who also introduced the kidney-shaped bowel for catching the water. Apart from that, small baglike syringes made of rubber were devised especially for use by the patient himself

  3. Design of liquid lithium pumps for FMIT

    International Nuclear Information System (INIS)

    Adkins, H.E.

    1983-01-01

    In the Fusion Materials Irradiation Test (FMIT) facility, a jet of liquid lithium is bombarded by accelerated deuterons to generate high energy neutrons for materials testing. The lithium system will include two electromagnetic pumps, a 750 gpm main pump and a 10 gpm auxiliary pump. The larger pump was designed and built in 1982, following extensive testing of a similar pump in the Experimental Lithium System. Design of the auxiliary pump has been completed, but fabrication has not started. This paper discusses the design considerations leading to selection of the Annular Linear Induction Pump (ALIP) concept for these applications. Design parameters, fabrication procedures, and results of pump testing are also reviewed

  4. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    Directory of Open Access Journals (Sweden)

    Carla Treloar

    Full Text Available A formal Needle and Syringe Program (NSP is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV risk and risk mitigation opportunities for inmates.The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons.A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison.The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  5. The Prison Economy of Needles and Syringes: What Opportunities Exist for Blood Borne Virus Risk Reduction When Prices Are so High?

    Science.gov (United States)

    Treloar, Carla; McCredie, Luke; Lloyd, Andrew R

    2016-01-01

    A formal Needle and Syringe Program (NSP) is not provided in Australian prisons. Injecting equipment circulates in prisons as part of an informal and illegal economy. This paper examined how this economy generates blood-borne virus (BBV) risk and risk mitigation opportunities for inmates. The HITS-p cohort recruited New South Wales inmates who had reported ever injecting drugs and who had a negative HCV serological test within 12 months prior to enrolment. For this study, qualitative interviews were conducted with 30 participants enrolled in HITS-p. Participants included 10 women and were incarcerated in 12 prisons. A needle/syringe was nominated as being typically priced in the 'inside' prison economy at $100-$150, with a range of $50-$350. Purchase or hire of equipment was paid for in cash (including transactions that occurred outside prison) and in exchange for drugs and other commodities. A range of other resources was required to enable successful needle/syringe economies, especially relationships with visitors and other prisoners, and violence to ensure payment of debts. Strategies to mitigate BBV risk included retaining one needle/syringe for personal use while hiring out others, keeping drug use (and ownership of equipment) "quiet", stealing used equipment from the prison health clinic, and manufacture of syringes from other items available in the prison. The provision of prison NSP would disrupt the inside economies built around contraband needles/syringes, as well as minimise BBV risk. However, any model of prison NSP should be interrogated for any unanticipated markets that could be generated as a result of its regulatory practices.

  6. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    Science.gov (United States)

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light

  7. Peristaltic pumps for waste disposal

    International Nuclear Information System (INIS)

    Griffith, G.W.

    1992-09-01

    Laboratory robots are capable of generating large volumes of hazardous liquid wastes when they are used to perform chemical analyses of metal finishing solutions. A robot at Allied-Signal Inc., Kansas City Division, generates 30 gallons of acid waste each month. This waste contains mineral acids, heavy metals, metal fluorides, and other materials. The waste must be contained in special drums that are closed to the atmosphere. The initial disposal method was to have the robot pour the waste into a collecting funnel, which contained a liquid-sensing valve to admit the waste into the drum. Spills were inevitable, splashing occurred, and the special valve often didn't work well. The device also occupied a large amount of premium bench space. Peristaltic pumps are made to handle hazardous liquids quickly and efficiently. A variable-speed pump, equipped with a quick-loading pump head, was mounted below the robot bench near the waste barrel. The pump inlet tube was mounted above the bench within easy reach of the robot, while the outlet tube was connected directly to the barrel. During operation, the robot brings the waste liquid up to the pump inlet tube and activates the pump. When the waste has been removed, the pump stops. The procedure is quick, simple, inexpensive, safe, and reliable

  8. Magnetohydrodynamic generator and pump system

    International Nuclear Information System (INIS)

    Birzvalk, Yu.A.; Karasev, B.G.; Lavrentyev, I.V.; Semikov, G.T.

    1983-01-01

    The MHD generator-pump system, or MHD coupling, is designed to pump liquid-metal coolant in the primary circuit of a fast reactor. It contains a number of generator and pump channels placed one after another and forming a single electrical circuit, but hydraulically connected parallel to the second and first circuits of the reactor. All the generator and pump channels are located in a magnetic field created by the magnetic system with an excitation winding that is fed by a regulated direct current. In 500 to 2000 MW reactors, the flow rate of the coolant in each loop of the primary circuit is 3 to 6 m 3 /s and the hydraulic power is 2 to 4 MW. This paper examines the primary characteristics of an MHD generator-pump system with various dimensions and number of channels, wall thicknesses, coolant flow rates, and magnetic fields. It is shown that its efficiency may reach 60 to 70%. The operating principle of the MHD generator-pump system is explained in the referenced patent and involves the transfer of hydraulic power from generator channels to pump channels using a magnetic field and electrical circuit common to both channels. Variations of this system may be analyzed using an equivalent circuit. 7 refs., 5 figs

  9. Electrostatic coupling of ion pumps.

    Science.gov (United States)

    Nieto-Frausto, J; Lüger, P; Apell, H J

    1992-01-01

    In this paper the electrostatic interactions between membrane-embedded ion-pumps and their consequences for the kinetics of pump-mediated transport processes have been examined. We show that the time course of an intrinsically monomolecular transport reaction can become distinctly nonexponential, if the reaction is associated with charge translocation and takes place in an aggregate of pump molecules. First we consider the electrostatic coupling of a single dimer of ion-pumps embedded in the membrane. Then we apply the treatment to the kinetic analysis of light-driven proton transport by bacteriorhodopsin which forms two-dimensional hexagonal lattices. Finally, for the case of nonordered molecules, we also consider a model in which the pumps are randomly distributed over the nodes of a lattice. Here the average distance is equal to that deduced experimentally and the elemental size of the lattice is the effective diameter of one single pump. This latter model is applied to an aggregate of membrane-embedded Na, K- and Ca-pumps. In all these cases the electrostatic potential considered is the exact solution calculated from the method of electrical images for a plane membrane of finite thickness immersed in an infinite aqueous solution environment. The distributions of charges (ions or charged binding sites) are considered homogeneous or discrete in the membrane and/or in the external solution. In the case of discrete distributions we compare the results from a mean field approximation and a stochastic simulation.

  10. Diffusion of renewable heating technologies in households. Experiences from the Norwegian Household Subsidy Programme

    International Nuclear Information System (INIS)

    Bjørnstad, Even

    2012-01-01

    A sample of 896 Norwegian households participating in a subsidy programme was surveyed in order to evaluate the success of the programme. The programme subsidised investments in new heating technologies, including heat pumps and pellet stoves. The success of the programme was measured by the degree of overall satisfaction with the investment by the sampled households. Theories on diffusion of innovations and planned behaviour motivate the empirical modelling of the investment satisfaction. The economic return on the investment varied substantially both within and between the two heating technologies, with heat pumps outperforming pellet stoves in this respect. Still, the economic return showed no explanatory power toward the investment satisfaction of the household. Among the economic variables, only the electricity price had any influence on investment satisfaction. Technical quality, indoor climate and heat comfort, and the availability of the supplier of the heating equipment were the most important explanatory variables. - Highlights: ► Investments in heat pumps and pellet stoves were subsidized over a public programme. ► Heat pumps showed a strong economic return, pellet stoves performed much more poorly. ► This difference in economic return does not influence the investment satisfaction. ► Technical quality, indoor climate and heat comfort are important benefits. ► Service availability and electricity price also influence satisfaction.

  11. Heat pumps - Even more efficient and quieter; Waermepumpen - noch effizienter und leiser

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, T.

    2003-07-01

    These comprehensive proceedings contain nine presentations made at the 10th Conference held by the Swiss Research Programme on Environmental Heat, Combined Heat and Power Generation (CHP) and Refrigeration in Burgdorf, Switzerland in June 2003. In a paper by Stefen Bertsch, Peter Hubacher and Prof. Dr. Max Ehrbar, methods of freeing the evaporators used in air-water heat pumps of ice is examined, Prof. Dr. Thomas Afjei introduces standardised schematics for heat pump installations, Dr. Hans Rudolf Graf presents the results of research into noise reduction for air-water heat pumps and Dr. Esfandiar Shafai reports on pulse-width-modulation for small heat pumps. A further paper covers the use of ammonia in small heat pumps (Ewald Geisser). Dr. Martin Zogg looks back on 10 years of heat pump research at the Swiss Federal Office of Energy whilst Prof. Dr. Thomas Kopp takes a look at the future activities of the programme. Finally, Prof. Dr. Max Ehrbar discusses strategies for and the implementation of pilot and demonstration plants.

  12. Analysis of mercury diffusion pumps

    International Nuclear Information System (INIS)

    Dunn, K.A.

    1991-01-01

    Several mercury diffusion pump stages in the Tritium Purification process at the Savannah River Site (SRS) have been removed from service for scheduled preventive maintenance. These stages have been examined to determine if failure has occurred. Evidence of fatigue around the flange portion of the pump has been seen. In addition, erosion and cavitation inside the throat of the venturi tube and corrosion on the other surface of the venturi tube has been observed. Several measures are being examined in an attempt to improve the performance of these pumps. These measures, as well as the noted observations, are described. 4 refs

  13. TFTR ultrahigh-vacuum pumping system incorporating mercury diffusion pumps

    International Nuclear Information System (INIS)

    Sink, D.A.; Sniderman, M.

    1976-06-01

    The TFTR vacuum vessel will have a system of four 61 cm diameter mercury diffusion pumps to provide a base pressure in the 10 -8 to 10 -9 Torr range as well as a low impurity level within the vessel. The system, called the Torus Vacuum Pumping System (TVPS), will be employed with the aid of an occasional 250 0 C bakeout in situ as well as periodic applications of aggressive discharge cleaning. The TVPS is an ultrahigh-vacuum (UHV) system using no elastomers as well as being a closed system with respect to tritium or any tritiated gases. The backing system employing approximately 75 all-metal isolation valves is designed with the features of redundancy and flexibility employed in a variety of ways to meet the fundamental requirements and functions enumerated for the TVPS. Since the design, is one which is a modification of the conceptual design of the TVPS, those features which have changed are discussed. Calculations are presented for the major performance parameters anticipated for the TVPS and include conductances, effective pumping speeds, base pressures, operating parameters, getter pump parameters, and calculations of time constants associated with leak checking. Modifications in the vacuum pumping system for the guard regions on the twelve bellows sections are presented so that it is compatible with the main TVPS. The bellows pumping system consists of a mechanical pump unit, a zirconium aluminum getter pump unit and a residual gas analyzer. The control and management of the TVPS is described with particular attention given to providing both manual and automatic control at a local station and at the TFTR Central Control. Such operations as testing, maintenance, leak checking, startup, bakeout, and various other operations are considered in some detail. Various aspects related to normal pulsing, discharge cleaning, non-tritium operations and tritium operations are also taken into consideration. A cost estimate is presented

  14. Test of a cryogenic helium pump

    International Nuclear Information System (INIS)

    Lue, J.W.; Miller, J.R.; Walstrom, P.L.; Herz, W.

    1981-01-01

    The design of a cryogenic helium pump for circulating liquid helium in a magnet and the design of a test loop for measuring the pump performance in terms of mass flow vs pump head at various pump speeds are described. A commercial cryogenic helium pump was tested successfully. Despite flaws in the demountable connections, the piston pump itself has performed satisfactorily. A helium pump of this type is suitable for the use of flowing supercritical helium through Internally Cooled Superconductor (ICS) magnets. It has pumped supercritical helium up to 7.5 atm with a pump head up to 2.8 atm. The maximum mass flow rate obtained was about 16 g/s. Performance of the pump was degraded at lower pumping speeds

  15. Fluidic pumping system

    International Nuclear Information System (INIS)

    Wilson, P.D.

    1995-01-01

    A fluidic pumping system comprises two charge vessels which communicate with a liquid inlet and a liquid outlet through a fluidic bridge rectifier. A pressurising and depressurising arrangement for alternately pressurising and depressurising the charge vessels comprises a chamber containing a piston and being in communication with the charge vessels. Drive means not mechanically connected to the piston are provided for causing reciprocatory movement of the piston. Movement of the piston in one direction causes pressurisation of one charge vessel to discharge a liquid therefrom through the liquid outlet. Simultaneously, the other charge vessel is depressurised to draw liquid from the liquid inlet into the depressurised charge vessel. Preferably, the drive means for the piston comprises an external solenoid winding at each end of a horizontally arranged chamber. Alternatively, the chamber may be vertically disposed with an external solenoid winding at the upper end of the chamber to effect upward movement of the piston, the piston then falling under gravity upon de-energisation of the winding. (UK)

  16. Exchangers man the pumps

    Science.gov (United States)

    Barkla, Bronwyn J; Hirschi, Kendal D

    2008-01-01

    Tonoplast-localised proton-coupled Ca2+ transporters encoded by cation/H+ exchanger (CAX) genes play a critical role in sequestering Ca2+ into the vacuole. These transporters may function in coordination with Ca2+ release channels, to shape stimulus-induced cytosolic Ca2+ elevations. Recent analysis of Arabidopsis CAX knockout mutants, particularly cax1 and cax3, identified a variety of phenotypes including sensitivity to abiotic stresses, which indicated that these transporters might play a role in mediating the plant's stress response. A common feature of these mutants was the perturbation of H+-ATPase activity at both the tonoplast and the plasma membrane, suggesting a tight interplay between the Ca2+/H+ exchangers and H+ pumps. We speculate that indirect regulation of proton flux by the exchangers may be as important as the direct regulation of Ca2+ flux. These results suggest cautious interpretation of mutant Ca2+/H+ exchanger phenotypes that may be due to either perturbed Ca2+ or H+ transport. PMID:19841670

  17. The INTEGRAL Core Observing Programme

    DEFF Research Database (Denmark)

    Winkler, C.; Gehrels, N.; Lund, Niels

    1999-01-01

    The Core Programme of the INTEGRAL mission is defined as the portion of the scientific programme covering the guaranteed time observations for the INTEGRAL Science Working Team. This paper describes the current status of the Core Programme preparations and summarizes the key elements...... of the observing programme....

  18. Reactor coolant purification system circulation pumps (CUW pumps)

    International Nuclear Information System (INIS)

    Tsutsui, Toshiaki

    1979-01-01

    Coolant purification equipments for BWRs have been improved, and the high pressure purifying system has become the main type. The quantity of purifying treatment also changed to 2% of the flow rate of reactor feed water. As for the circulation pumps, canned motor pumps are adopted recently, and the improvements of reliability and safety are attempted. The impurities carried in by reactor feed water and the corrosion products generated in reactors and auxiliary equipments are activated by neutron irradiation or affect heat transfer adversely, adhering to fuel claddings are core structures. Therefore, a part of reactor coolant is led to the purification equipments, and returned to reactors after the impurities are eliminated perfectly. At the time of starting and stopping reactors, excess reactor water and the contaminated water from reactors are transferred to main condenser hot wells or waste treatment systems. Thus the prescribed water quality is maintained. The operational modes of and the requirements for the CUW pumps, the construction and the features of the canned motor type CUW pumps are explained. Recently, a pump operated for 11 months without any maintenance has been disassembled and inspected, but the wear of bearings has not been observed, and the high reliability of the pump has been proved. (Kako, I.)

  19. Pump failure leads to alternative vertical pump condition monitoring technique

    International Nuclear Information System (INIS)

    DeVilliers, Adriaan; Glandon, Kevin

    2011-01-01

    Condition monitoring and detecting early signs of potential failure mechanisms present particular problems in vertical pumps. Most often, the majority of the pump assembly is not readily accessible for visual or audible inspection or conventional vibration monitoring techniques using accelerometers and/or proximity sensors. The root cause failure analysis of a 2-stage vertical centrifugal service-water pump at a nuclear power generating facility in the USA is presented, highlighting this long standing challenge in condition monitoring of vertical pumps. This paper will summarize the major findings of the root cause analysis (RCA), highlight the limitations of traditional monitoring techniques, and present an expanded application of motor current monitoring as a means to gain insight into the mechanical performance and condition of a pump. The 'real-world' example of failure, monitoring and correlation of the monitoring technique to a detailed pump disassembly inspection is also presented. This paper will explain some of the reasons behind well known design principles requiring natural frequency separation from known forcing frequencies, as well as explore an unexpected submerged brittle fracture failure mechanism, and how such issues may be avoided. (author)

  20. Magnetic heat pump flow director

    Science.gov (United States)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  1. Heat pumps at the maltings

    Energy Technology Data Exchange (ETDEWEB)

    1987-11-01

    Heat pumps have halved the energy costs of producing finished malt at two of the country's maltsters. The fuel-fired kilning processes described are now performed by heat pumps with considerable energy and production benefits at the maltings of J.P. Simpson and Co. (Alnwick) Ltd, in Tivetshall St Margaret, Norfolk, and of Munton and Fison Plc of Stowmarket, Suffolk. The heat pump system installed at the Station Malting of J.P. Simpson was devised by the Electricity Council Research Centre at Capenhurst near Chester. Energy cost benefits of Pound 6,000 a month are being realised at Simpsons, but there is the added benefit that the system has been designed to provide conditioned air to the germination cycle to ensure that the correct temperature is maintained throughout the year. At the Cedars factory of Munton and Fison, heat pumps were used on a trial basis for plant micropropagation and for a fish farming unit.

  2. ENERGY STAR Certified Pool Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.1 ENERGY STAR Program Requirements for Pool Pumps that are effective as of February 15,...

  3. Feed pumps for a NPP

    International Nuclear Information System (INIS)

    Rzhebaev, Eh.E.; Zhukov, V.M.; Evtushenko, A.A.

    1977-01-01

    Given is a brief description of results of designing and testing the PE850-65 and SPE1650-75 pilot feed pumps for 440 MWe pressurized water reactors and for 1000 MWe boiling water reactors. Described is a bench-mark facility for the SPE1650-75 pump with full-scale parameters. The adjustment results of the preconnected axial wheel of the 1PE1650-75 pump during the service life tests of a pilot pump have been given. Practical results on new methods of the preconnected axial wheel protection have been obtained. The design criteria developed provide for the long life time within the proven range of circular velocities. Confirmed is a possibility of carrying out advanced tests for estimating the cavitation destruction intensity using the vibration due to cavitation

  4. Balanced pressure gerotor fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Raney, Michael Raymond; Maier, Eugen

    2004-08-03

    A gerotor pump for pressurizing gasoline fuel is capable of developing pressures up to 2.0 MPa with good mechanical and volumetric efficiency and satisfying the durability requirements for an automotive fuel pump. The pump has been designed with optimized clearances and by including features that promote the formation of lubricating films of pressurized fuel. Features of the improved pump include the use of a shadow port in the side plate opposite the outlet port to promote balancing of high fuel pressures on the opposite sides of the rotors. Inner and outer rotors have predetermined side clearances with the clearances of the outer rotor being greater than those of the inner rotor in order to promote fuel pressure balance on the sides of the outer rotor. Support of the inner rotor and a drive shaft on a single bushing with bearing sleeves maintains concentricity. Additional features are disclosed.

  5. Heat Pumps in Subarctic Areas

    DEFF Research Database (Denmark)

    Atlason, Reynir Smari; Oddsson, Gudmundur Valur; Unnthorsson, Runar

    2017-01-01

    Geothermal heat pumps use the temperature difference between inside and outside areas to modify a refrigerant, either for heating or cooling. Doing so can lower the need for external heating energy for a household to some extent. The eventual impact depends on various factors, such as the external...... source for heating or cooling and the temperature difference. The use of geothermal heat pumps, and eventual benefits has not been studied in the context of frigid areas, such as in Iceland. In Iceland, only remote areas do not have access to district heating from geothermal energy where households may...... therefor benefit from using geothermal heat pumps. It is the intent of this study to explore the observed benefits of using geothermal heat pumps in Iceland, both financially and energetically. This study further elaborates on incentives provided by the Icelandic government. Real data was gathered from...

  6. Transverse pumped laser amplifier architecture

    Science.gov (United States)

    Bayramian, Andrew James; Manes, Kenneth; Deri, Robert; Erlandson, Al; Caird, John; Spaeth, Mary

    2013-07-09

    An optical gain architecture includes a pump source and a pump aperture. The architecture also includes a gain region including a gain element operable to amplify light at a laser wavelength. The gain region is characterized by a first side intersecting an optical path, a second side opposing the first side, a third side adjacent the first and second sides, and a fourth side opposing the third side. The architecture further includes a dichroic section disposed between the pump aperture and the first side of the gain region. The dichroic section is characterized by low reflectance at a pump wavelength and high reflectance at the laser wavelength. The architecture additionally includes a first cladding section proximate to the third side of the gain region and a second cladding section proximate to the fourth side of the gain region.

  7. Method for controlling powertrain pumps

    Science.gov (United States)

    Sime, Karl Andrew; Spohn, Brian L; Demirovic, Besim; Martini, Ryan D; Miller, Jean Marie

    2013-10-22

    A method of controlling a pump supplying a fluid to a transmission includes sensing a requested power and an excess power for a powertrain. The requested power substantially meets the needs of the powertrain, while the excess power is not part of the requested power. The method includes sensing a triggering condition in response to the ability to convert the excess power into heat in the transmission, and determining that an operating temperature of the transmission is below a maximum. The method also includes determining a calibrated baseline and a dissipation command for the pump. The calibrated baseline command is configured to supply the fluid based upon the requested power, and the dissipation command is configured to supply additional fluid and consume the excess power with the pump. The method operates the pump at a combined command, which is equal to the calibrated baseline command plus the dissipation command.

  8. Printing and Curing of Conductive Ink Track on Fabric using Syringe Deposition System with DLP Projector and Hot Plate

    Directory of Open Access Journals (Sweden)

    Khirotdin Rd. Khairilhijra

    2017-01-01

    Full Text Available Printing is a technique to transfer ink onto substrates to create pattern and syringe deposition system has shown some great potential in printing due to its ability to produce filamentary bead tracks which is important concerning conductivity and easily adopted on conformal surfaces which could not be realized by conventional technique. Fabrics with integrated electrical features able to create intelligent articles and may potentially open up new perspective areas of application in textile printing. However, the applicability of this technique on fabrics remains unknown which the ink used has to meet certain requirements including high electrical conductivity, resistance to oxidation, dry out without clogging, good adhesion with suitable viscosity and surface tension. Thus, there is a need to do this study which is to determine the feasibility of syringe deposition system to print a conductive ink tracks using silver epoxy-based conductive ink on fabric substrate via lycra material. This study is also aim to investigate the feasibility of using DLP projector with hot plate as another source of heat to be used in curing the ink tracks on fabric. The effect of printing and curing parameters to the characteristics and conductivity of the ink track is investigated. Several mechanical and electrical tests were also administered to determine the cure, hardness, adhesion and resistance level of the ink tracks. The results obtained were as expected which higher printing speed and lower deposition height used, a narrower and thinner ink tracks were produced. Sample with 4 mm/s of printing speed and deposition height of 1 mm resulted in dimension closer to the targeted dimension. The longer curing time and higher temperature used, a lower resistance is produced. The lowest resistance achieved is 0.9 Ω cured at 150°C for 60 minutes. The conductivity of the ink track was affected by curing process and cross-sectional area of the ink track. It is proven

  9. Comparison of drug delivery with autoinjector versus manual prefilled syringe and between three different autoinjector devices administered in pig thigh

    Directory of Open Access Journals (Sweden)

    Hill RL

    2016-08-01

    Full Text Available Robert L Hill,1,* John G Wilmot,1,* Beth A Belluscio,1 Kevin Cleary,2 David Lindisch,3 Robin Tucker,4 Emmanuel Wilson,2 Rajesh B Shukla11Meridian Medical Technologies Inc., Columbia, MD, 2Children’s National Medical Center, 3Washington DC VA Medical Center, 4Georgetown University Medical Center, Washington, DC, USA *These authors have contributed equally to this work Abstract: Parenteral routes of drug administration are often selected to optimize actual dose of drug delivered, assure high bioavailability, bypass first-pass metabolism or harsh gastrointestinal environments, as well as maximize the speed of onset. Intramuscular (IM delivery can be preferred to intravenous delivery when initiating intravenous access is difficult or impossible. Drugs can be injected intramuscularly using a syringe or an automated delivery device (autoinjector. Investigation into the IM delivery dynamics of these methods may guide further improvements in the performance of injection technologies. Two porcine model studies were conducted to compare differences in dispersion of injectate volume for different methods of IM drug administration. The first study compared the differences in the degree of dispersion and uptake of injectate following the use of a manual syringe and an autoinjector. The second study compared the spatial spread of the injected formulation, or dispersion volume, and uptake of injectate following the use of five different autoinjectors (EpiPen® [0.3 mL], EpiPen® Jr [0.3 mL], Twinject® [0.15 mL, 0.3 mL], and Anapen® 300 [0.3 mL] with varying needle length, needle gauge, and force applied to the plunger. In the first study, the autoinjector provided higher peak volumes of injectate, indicating a greater degree of dispersion, compared with manual syringe delivery. In the second study, EpiPen autoinjectors resulted in larger dispersion volumes and higher initial dispersion ratios, which decreased rapidly over time, suggesting a greater

  10. Decontamination of main coolant pumps

    International Nuclear Information System (INIS)

    Roofthooft, R.

    1988-01-01

    Last year a number of main coolant pumps in Belgian nuclear power plants were decontaminated. A new method has been developed to reduce the time taken for decontamination and the volume of waste to be treated. The method comprises two phases: Oxidation with permanganate in nitric acid and dissolution in oxalic acid. The decontamination of main coolant pumps can now be achieved in less than one day. The decontamination factors attained range between 15 and 150. (orig.) [de

  11. Pitfalls of Insulin Pump Clocks

    Science.gov (United States)

    Reed, Amy J.

    2014-01-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713

  12. Magnon transport through microwave pumping

    OpenAIRE

    Nakata Kouki; Simon Pascal; Loss Daniel

    2015-01-01

    We present a microscopic theory of magnon transport in ferromagnetic insulators (FIs). Using magnon injection through microwave pumping, we propose a way to generate magnon dc currents and show how to enhance their amplitudes in hybrid ferromagnetic insulating junctions. To this end focusing on a single FI, we first revisit microwave pumping at finite (room) temperature from the microscopic viewpoint of magnon injection. Next, we apply it to two kinds of hybrid ferromagnetic insulating juncti...

  13. Pump for extremely dangerous liquids

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav

    2011-01-01

    Roč. 89, č. 7A (2011), s. 940-956 ISSN 0263-8762 R&D Projects: GA ČR GA101/07/1499; GA AV ČR IAA200760705 Institutional research plan: CEZ:AV0Z20760514 Keywords : pump * jet pump * coanda effect Subject RIV: BK - Fluid Dynamics Impact factor: 1.968, year: 2011 http://www.sciencedirect.com/science/article/pii/S0263876210003631

  14. A review of the Italian fast reactor programme

    International Nuclear Information System (INIS)

    Pierantoni, F.; Tavoni, R.

    1989-01-01

    The result of the referenda held in Italy in November 1987 on some nuclear issues, and the subsequent attitude of the main political parties led to a sharp cut-back of nuclear activities in Italy as far as both construction and operation of nuclear plants are concerned. A new PEN (National Energy Plan), already approved by the government for submission to parliament, calls, however, for a programme of research and industrial development of reactors with inherent and passive safety features. Such a programme must be carried out in a framework of international co-operation. In addition to the Italian contribution to R and D activities performed under the European Agreements some further activities have been performed on Esmeralda Programme, seismic isolation, Integrity of structures and Primary and Intermediate Pumps. (author). 2 tabs

  15. The French nuclear programme

    International Nuclear Information System (INIS)

    Feger, M.

    1990-01-01

    EDF has long been interested in the use of nuclear energy for thermal power generation. After a period of apprenticeship and experiments, EDF launched a major PWR plant programme so as to reduce France's energy dependence and master generation costs. This programme, based on standardization, has achieved the desired results. It must now be adapted to suit the needs of the 21st century. For this programme, all those involved (Governmental authorities, EDF, manufacturers) were mobilized to an unprecedented extent and rigorous working methods were imposed. Experience feedback has been used to make improvements both to the installations themselves and to procedures. Results have proved satisfactory as regards nuclear safety but vigilance must be maintained. Public opinion on nuclear power is reserved we are sentenced to achieving a 'fault-free' track record, all the while mastering costs, so as to ensure the continuing use of nuclear energy. (author)

  16. The French nuclear programme

    Energy Technology Data Exchange (ETDEWEB)

    Feger, M [Ecole Nationale Superieure d' Electrotechnique de Grenoble, Institute National des Sciences et Techniques Nucleaires (Saclay), Gif-sur-Yvette, Electricite de France (France)

    1990-06-01

    EDF has long been interested in the use of nuclear energy for thermal power generation. After a period of apprenticeship and experiments, EDF launched a major PWR plant programme so as to reduce France's energy dependence and master generation costs. This programme, based on standardization, has achieved the desired results. It must now be adapted to suit the needs of the 21st century. For this programme, all those involved (Governmental authorities, EDF, manufacturers) were mobilized to an unprecedented extent and rigorous working methods were imposed. Experience feedback has been used to make improvements both to the installations themselves and to procedures. Results have proved satisfactory as regards nuclear safety but vigilance must be maintained. Public opinion on nuclear power is reserved we are sentenced to achieving a 'fault-free' track record, all the while mastering costs, so as to ensure the continuing use of nuclear energy. (author)

  17. External Mobility Programme

    CERN Multimedia

    HR Department

    2007-01-01

    Every year, a significant number of highly-skilled staff members leave the Organization and offer their talents on the European job market. CERN is launching a programme aiming to help staff members to whom the Organization cannot offer an indefinite contract in the transition towards their next employment. The programme, which is based on the establishment of a number of partnerships with potential employers in the private sector, will run on a voluntary basis. Staff members who have received confirmation that they will not be offered an indefinite contract and who are interested in availing themselves of the opportunities offered by the programme, are invited to enrol by following the procedure described at: https://ert.cern.ch/browse_intranet/wd_pds?p_web_page_id=5841 Applications will be processed in the strictest confidence by the Human Resources Department and eligible profiles will then be made available to partner companies for recruitment purposes. Any subsequent ...

  18. 46 CFR 181.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 181.300 Section 181.300 Shipping COAST GUARD... EQUIPMENT Fire Main System § 181.300 Fire pumps. (a) A self priming, power driven fire pump must be..., the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not...

  19. 14 CFR 25.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 25.991 Section 25.991... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.991 Fuel pumps. (a) Main pumps. Each fuel pump required for proper engine operation, or required to meet the fuel system...

  20. 46 CFR 118.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 118.300 Section 118.300 Shipping COAST GUARD... Fire pumps. (a) A self priming, power driven fire pump must be installed on each vessel. (b) On a..., the fire pump must be capable of delivering a single hose stream from the highest hydrant, through the...

  1. Method for optimising the energy of pumps

    NARCIS (Netherlands)

    Skovmose Kallesøe, Carsten; De Persis, Claudio

    2011-01-01

    The method involves determining whether pumps (pu1, pu5) are directly assigned to loads (v1, v3) as pilot pumps (pu2, pu3) and hydraulically connected upstream of the pilot pumps. The upstream pumps are controlled with variable speed for energy optimization. Energy optimization circuits are selected

  2. METHOD FOR OPTIMIZING THE ENERGY OF PUMPS

    NARCIS (Netherlands)

    Skovmose Kallesøe, Carsten; De Persis, Claudio

    2013-01-01

    The device for energy-optimization on operation of several centrifugal pumps controlled in rotational speed, in a hydraulic installation, begins firstly with determining which pumps as pilot pumps are assigned directly to a consumer and which pumps are hydraulically connected in series upstream of

  3. 46 CFR 105.20-10 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pumps. 105.20-10 Section 105.20-10 Shipping COAST GUARD... DISPENSING PETROLEUM PRODUCTS Specific Requirements-Cargo Tanks § 105.20-10 Pumps. (a) Pumps for cargo... discharge side of pump if the pressure under shutoff conditions exceeds 60 pounds. When a relief valve is...

  4. 46 CFR 182.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ...) Highly resistant to salt water, petroleum oil, heat, and vibration. (g) If a fixed hand pump is used to... GPM). (b) A portable hand bilge pump must be: (1) Capable of pumping water, but not necessarily..., including wiring, and size and number of batteries, is designed to allow all bilge pumps to be operated...

  5. Probabilistic programmable quantum processors

    International Nuclear Information System (INIS)

    Buzek, V.; Ziman, M.; Hillery, M.

    2004-01-01

    We analyze how to improve performance of probabilistic programmable quantum processors. We show how the probability of success of the probabilistic processor can be enhanced by using the processor in loops. In addition, we show that an arbitrary SU(2) transformations of qubits can be encoded in program state of a universal programmable probabilistic quantum processor. The probability of success of this processor can be enhanced by a systematic correction of errors via conditional loops. Finally, we show that all our results can be generalized also for qudits. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  6. A programme in transition

    International Nuclear Information System (INIS)

    Dean, S.O.

    1992-01-01

    Fusion is beginning its transition from a scientific research programme to that of an engineering development programme aimed at practical applications. This transition is likely to last a decade or more because many scientific questions remain and because of the magnitude and cost of the engineering issues. This article reviews briefly the encouraging results produced at the Joint European Torus (JET) where 1.7 MW of fusion power was generated for 2 seconds in experiments in November 1991, the remaining scientific issues, the role of near-term experimental reactors like the International Thermonuclear Experimental reactor (ITER) and other approaches to a demonstration power plant. (author)

  7. Computer mathematics for programmers

    CERN Document Server

    Abney, Darrell H; Sibrel, Donald W

    1985-01-01

    Computer Mathematics for Programmers presents the Mathematics that is essential to the computer programmer.The book is comprised of 10 chapters. The first chapter introduces several computer number systems. Chapter 2 shows how to perform arithmetic operations using the number systems introduced in Chapter 1. The third chapter covers the way numbers are stored in computers, how the computer performs arithmetic on real numbers and integers, and how round-off errors are generated in computer programs. Chapter 4 details the use of algorithms and flowcharting as problem-solving tools for computer p

  8. Test report for the run-in acceptance testing of the hydrogen mitigation retrieval Pump-3

    International Nuclear Information System (INIS)

    Berglin, B.G.; Nash, Ch.R.

    1997-01-01

    This report will provide the findings of the demonstration test conducted on the Double-Shell Tank (DST) 241-SY-101 HMR Pump-3 in accordance with WHC-SDWM-TP-434 ''Test plan for run-in acceptance testing of hydrogen mitigation/retrieval pump-3'' at the 400 Area Maintenance and Storage Facility (MASF) building from 7 June 1996 through 30 July 1996 per work package 4A-96-92/W. The DST 241-SY-101 hydrogen mitigation retrieval Pump-3 is a 200-HP submersible electric driven pump that has been modified for use in the DST 241-SY-101 containing mixed waste located in the 200W area. The pump has a motor driven rotation mechanism that allows the pump column to rotate through 355 degree. Prior to operation, pre-operational checks were performed which included loop calibration grooming and alignment of instruments, learning how plumb HMR-3 assembly hung in a vertical position and bump test of the motor to determine rotation direction. The pump was tested in the MASF Large Diameter Cleaning Vessel (LDCV) with process water at controlled temperatures and levels. In addition, the water temperature of the cooling water to the motor oil heat exchanger was recorded during testing. A 480-volt source powered a Variable Frequency Drive (VFD). The VFD powered the pump at various frequencies and voltages to control speed and power output of the pump. A second VFD powered the oil cooling pump. A third VFD was not available to operate the rotational drive motor during the 72 hour test, so it was demonstrated as operational before and after the test. A Mini Acquisition and Control System (Mini-DACS) controls pump functions and monitoring of the pump parameters. The Mini-DACS consists of three computers, software and some Programmable Logic Controllers (PLC). Startup and shutdown of either the pump motor or the oil cooling pump can be accomplished by the Mini-DACS. When the pump was in operation, the Mini-DACS monitors automatically collects data electronically. However, some required data

  9. Stability of Fentanyl Citrate, Hydromorphone Hydrochloride, Ketamine Hydrochloride, Midazolam, Morphine Sulfate, and Pentobarbital Sodium in Polypropylene Syringes

    OpenAIRE

    Anderson, Collin; MacKay, Mark

    2015-01-01

    Purpose: Determine the stability of fentanyl 10 mcg/mL in 0.9% sodium chloride, fentanyl 10 mcg/mL in 5% dextrose, fentanyl 50 mcg/mL, hydromorphone 100 mcg/mL in 0.9% sodium chloride, ketamine 10 mg/mL, midazolam 0.4 mg/mL in 5% dextrose, midazolam 5 mg/mL, morphine 1 mg/mL in 0.9% sodium chloride, morphine 1 mg/mL in 5% dextrose, and pentobarbital 50 mg/mL when stored as single drug entities at room temperature in polypropylene syringes. Methods: Four 5 mL samples of each drug and concentra...

  10. Identification of Catechin, Syringic Acid, and Procyanidin B2 in Wine as Stimulants of Gastric Acid Secretion.

    Science.gov (United States)

    Liszt, Kathrin Ingrid; Eder, Reinhard; Wendelin, Sylvia; Somoza, Veronika

    2015-09-09

    Organic acids of wine, in addition to ethanol, have been identified as stimulants of gastric acid secretion. This study characterized the influence of other wine compounds, particularly phenolic compounds, on proton secretion. Forty wine parameters were determined in four red wines and six white wines, including the contents of organic acids and phenolic compounds. The secretory activity of the wines was determined in a gastric cell culture model (HGT-1 cells) by means of a pH-sensitive fluorescent dye. Red wines stimulated proton secretion more than white wines. Lactic acid and the phenolic compounds syringic acid, catechin, and procyanidin B2 stimulated proton secretion and correlated with the pro-secretory effect of the wines. Addition of the phenolic compounds to the least active white wine sample enhanced its proton secretory effect by 65 ± 21% (p astringent tasting phenolic compounds in wine contribute to its stimulatory effect on gastric acid secretion.

  11. Continuous subcutaneous delivery of medications for home care palliative patients-using an infusion set or a pump?

    Science.gov (United States)

    Menahem, Sasson; Shvartzman, Pesach

    2010-09-01

    The purpose of this study was to evaluate safety, feasibility, and efficacy of continuous drug delivery by the subcutaneous route through a solution bag connected to an infusion set compared with an infusion pump in a home palliative care setting. Patients in need of continuous subcutaneous medication delivery for pain control, nausea, and/or vomiting were recruited. The study was designed as a double-blind, crossover study. The patient was connected to two parallel subcutaneous lines running simultaneously, connected together to a line entering the subcutaneous tissue. One line is connected to an infusion set and the other to a pump. The infusion set included a 500-cc solution bag connected to a 1.5-m plastic tube containing a drip chamber controlled by a roller clamp that is gravity driven without hyaluronidase. Active medications were randomly assigned to start in either administration method and switched after 24 h. An independent research assistant evaluated symptom control and side effects at baseline and every 24 h for 2 days using a structured questionnaire. Another independent research assistant connected the lines after adding medications and evaluated technical and clinical failures. Twenty-seven patients were recruited, and of them, 18 completed the study. Incidents in fluid administration were more common through the infusion set (18 times) compared to the pump (only twice). On the other hand, no clinical significant change was noted in the average symptom levels and side effects when medications were given through the infusion set versus the pump. No local edema or irritation was observed in either way of administration. In a home palliative care setting with a medical staff on call for 24 h, using medications for symptom control can be considered to be infused to a fluid solution bag through an infusion set instead of using a syringe driver or a pump when there is a responsible caregiver to follow up on the fluid. Subcutaneous constant drug delivery

  12. Cultivation and Differentiation of Encapsulated hMSC-TERT in a Disposable Small-Scale Syringe-Like Fixed Bed Reactor

    DEFF Research Database (Denmark)

    Weber, Christian; Pohl, Sebastian; Pörtner, Ralf

    2007-01-01

    The use of commercially available plastic syringes is introduced as disposable small-scale fixed bed bioreactors for the cultivation of implantable therapeutic cell systems on the basis of an alginate-encapsulated human mesenchymal stem cell line. The system introduced is fitted with a noninvasiv...

  13. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  14. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  15. In-syringe extraction using dissolvable layered double hydroxide-polymer sponges templated from hierarchically porous coordination polymers.

    Science.gov (United States)

    Ghani, Milad; Frizzarin, Rejane M; Maya, Fernando; Cerdà, Víctor

    2016-07-01

    Herein we report the use of cobalt porous coordination polymers (PCP) as intermediates to prepare advanced extraction media based on layered double hydroxides (LDH) supported on melamine polymer foam. The obtained dissolvable Ni-Co LDH composite sponges can be molded and used as sorbent for the in-syringe solid-phase extraction (SPE) of phenolic acids from fruit juices. The proposed sorbent is obtained due to the surfactant-assisted self-assembly of Co(II)/imidazolate PCPs on commercially available melamine foam, followed by the in situ conversion of the PCP into the final dissolvable LDH coating. Advantageous features for SPE are obtained by using PCPs with hierarchical porosity (HPCPs). The LDH-sponge prepared using intermediate HPCPs (HLDH-sponge) is placed in the headspace of a glass syringe, enabling flow-through extraction followed by analyte elution by the dissolution of the LDH coating in acidic conditions. Three phenolic acids (gallic acid, p-hydroxybenzoic acid and caffeic acid) were extracted and quantified using high performance liquid chromatography. Using a 5mL sample volume, the obtained detection limits were 0.15-0.35μgL(-1). The proposed method for the preparation of HLDH-sponges showed a good reproducibility as observed from the intra- and inter-day RSD's, which were <10% for all analytes. The batch-to-batch reproducibility for three different batches of HLDH-sponges was 10.6-11.2%. Enrichment factors of 15-21 were obtained. The HLDH-sponges were applied satisfactorily to the determination of phenolic acids in natural and commercial fruit juices, obtaining relative recoveries among 89.7-95.3%. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Apical negative pressure irrigation versus syringe irrigation: a systematic review of cleaning and disinfection of the root canal system.

    Science.gov (United States)

    Konstantinidi, E; Psimma, Z; Chávez de Paz, L E; Boutsioukis, C

    2017-11-01

    The aim of this study was to systematically review and critically analyse the published data on the treatment outcome (primary outcome) and on the cleaning and disinfection of root canals (secondary outcomes) achieved by negative pressure irrigation as compared to syringe irrigation. An electronic search was conducted in EMBASE, LILACS, PubMed, SciELO, Scopus and Web of Knowledge using both free-text keywords and controlled vocabulary. Additional studies were sought through hand searching of endodontic journals and of the relevant chapters of endodontic textbooks. No language restriction was imposed. The retrieved studies were screened by two reviewers according to predefined criteria. Included studies were critically appraised and the extracted data were arranged in tables. The electronic search and hand search retrieved 489 titles. One clinical study and 14 in vitro studies were finally included in the review; none of these studies assessed treatment outcome, four studies assessed the antimicrobial effect, seven studies evaluated the removal of pulp tissue remnants, and four studies investigated the removal of hard tissue debris or both hard tissue debris and pulp tissue remnants. Poor standardization and description of the protocols was evident. Inconclusive results were reported about the cleaning and disinfection accomplished by the two irrigation methods. Negative pressure irrigation was more effective under certain conditions when compared to suboptimal syringe irrigation; however, the variability of the protocols hindered quantitative synthesis. There is insufficient evidence to claim general superiority of any one of these methods. The level of the available evidence is low, and the conclusions should be interpreted with caution. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  17. Assessment of an in vitro whole cigarette smoke exposure system: The Borgwaldt RM20S 8-syringe smoking machine

    Directory of Open Access Journals (Sweden)

    McAughey John

    2011-08-01

    Full Text Available Abstract Background There have been many recent developments of in vitro cigarette smoke systems closely replicating in vivo exposures. The Borgwaldt RM20S smoking machine (RM20S enables the serial dilution and delivery of cigarette smoke to exposure chambers for in vitro analyses. In this study we have demonstrated reliability and robustness testing of the RM20S in delivering smoke to in vitro cultures using an in-house designed whole smoke exposure chamber. Results The syringe precision and accuracy of smoke dose generated by the RM20S was assessed using a methane gas standard and resulted in a repeatability error of ≤9%. Differential electrical mobility particle spectrometry (DMS measured smoke particles generated from reference 3R4F cigarettes at points along the RM20S. 53% ± 5.9% of particles by mass reached the chamber, the remainder deposited in the syringe or connecting tubing and ~16% deposited in the chamber. Spectrofluorometric quantification of particle deposition within chambers indicated a positive correlation between smoke concentration and particle deposition. In vitro air-liquid interface (ALI cultures (H292 lung epithelial cells, exposed to whole smoke (1:60 dilution (smoke:air, equivalent to ~5 μg/cm2 demonstrated uniform smoke delivery within the chamber. Conclusions These results suggest this smoke exposure system is a reliable and repeatable method of generating and exposing ALI in vitro cultures to cigarette smoke. This system will enable the evaluation of future tobacco products and individual components of cigarette smoke and may be used as an alternative in vitro tool for evaluating other aerosols and gaseous mixtures such as air pollutants, inhaled pharmaceuticals and cosmetics.

  18. NERATOOM work on pump development

    International Nuclear Information System (INIS)

    Hoornweg, C.J.

    1976-01-01

    The prototype pump has been manufactured by Stork Engineerings Works at Hengelo in 1969. The full-scale test on water has been carried out as part of the procedures of acceptance. Tests on sodium have been carried out in the pumptestfacility of Interatom at Bensberg (W. Germany); these tests started in March 1971 and were finished in October 1972. During that period nearly 6000 hours of pump testing were accomplished, of which 150 hours the pump was subjected to cavitation. During 30 hours the pump was subjected to a cavitation intensity of more than 3% loss of delivery head. At some occasions the loss of delivery head was 7%. The measured NPSH with the tests on sodium was 10m, whereas the NPSH obtained with the tests on water was 9m. Attempts have been made to account for this difference of NPSH-setting on the two liquids concerned. At the end of the tests on sodium (that is after the excecution of the cavitation tests) the delivery head of the pump was 2 m.l.c. less than the rated value. After dismantling the pump it appeared that the surface of the impeller vanes was roughened, especially at those parts where the original sand cast surface had not been polished. Based on the testresults and not being contradicted by calculation-results so far, our opinion is that cavitation in sodium of reactor temperature (550 0 C) most probably is of the same order of magnitude as it is in water of roomtemperature under the same conditions of NPSH, provided the same pump operates in systems that are exact replica of one another

  19. Mexican medfly programme

    International Nuclear Information System (INIS)

    1980-01-01

    This film tells the story of the fight against and final extinction of the Mediterranean fruit-fly (Ceratitis capitata) in Mexico. By producing billions of high quality sterile flies in the Medfly reproduction and sterilization laboratory in the province of Chiapas and releasing them over infested areas, the Moscamed Programme succeeded in eradicating this pest from Mexico in 1982

  20. Nuclear safety. Improvement programme

    International Nuclear Information System (INIS)

    2000-01-01

    In this brochure the improvement programme of nuclear safety of the Mochovce NPP is presented in detail. In 1996, a 'Mochovce NPP Nuclear Safety Improvement Programme' was developed in the frame of unit 1 and 2 completion project. The programme has been compiled as a continuous one, with the aim to reach the highest possible safety level at the time of commissioning and to establish good preconditions for permanent safety improvement in future. Such an approach is in compliance with the world's trends of safety improvement, life-time extension, modernisation and nuclear station power increase. The basic document for development of the 'Programme' is the one titled 'Safety Issues and their Ranking for WWER 440/213 NPP' developed by a group of IAEA experts. The following organisations were selected for solution of the safety measures: EUCOM (Consortium of FRAMATOME, France, and SIEMENS, Germany); SKODA Prague, a.s.; ENERGOPROJEKT Prague, a.s. (EGP); Russian organisations associated in ATOMENERGOEXPORT; VUJE Trnava, a.s

  1. Progressive Retirement Programme

    CERN Document Server

    HR Department

    2009-01-01

    Following the Standing Concertation Committee meeting of 2 December 2008, please note that the Progressive Retirement Programme has been extended by one year, i.e. until 31 March 2010. Further information is available on : https://hr-services.web.cern.ch/hr-services/services-Ben/prp/prp.asp HR Department, tel. 73903

  2. Fusion technology programme

    International Nuclear Information System (INIS)

    Finken, D.

    1985-10-01

    KfK is involved in the European Fusion Programme predominantly in the NET and Fusion Technology part. The following fields of activity are covered: Studies for NET, alternative confinement concepts, and needs and issues of integral testing. Research on structural materials. Development of superconducting magnets. Gyrotron development (part of the Physics Programme). Nuclear technology (breeding materials, blanket design, tritium technology, safety and environmental aspects of fusion, remote maintenance). Reported here are status and results of work under contracts with the CEC within the NET and Technology Programme. The aim of the major part of this R and D work is the support of NET, some areas (e.g. materials, safety and environmental impact, blanket design) have a wider scope and address problems of a demonstration reactor. In the current working period, several new proposals have been elaborated to be implemented into the 85/89 Euratom Fusion Programme. New KfK contributions relate to materials research (dual beam and fast reactor irradiations, ferritic steels), to blanket engineering (MHD-effects) and to safety studies (e.g. magnet safety). (orig./GG)

  3. SET-Routes programme

    CERN Multimedia

    Marietta Schupp, EMBL Photolab

    2008-01-01

    Dr Sabine Hentze, specialist in human genetics, giving an Insight Lecture entitled "Human Genetics – Diagnostics, Indications and Ethical Issues" on 23 September 2008 at EMBL Heidelberg. Activities in a achool in Budapest during a visit of Angela Bekesi, Ambassadors for the SET-Routes programme.

  4. Programmable dc motor controller

    Science.gov (United States)

    Hopwood, J. E.

    1982-11-01

    A portable programmable dc motor controller, with features not available on commercial instruments was developed for controlling fixtures during welding processes. The controller can be used to drive any dc motor having tachometer feedback and motor requirements not exceeding 30 volts, 3 amperes. Among the controller's features are delayed start time, upslope time, speed, and downslope time.

  5. Exchange and fellowship programme

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1959-04-15

    By February 1959, the IAEA had received and considered nearly 300 nominations from 31 countries for nuclear science fellowships. More than 200 of the candidates - from 29 countries - had been selected for placement in centres of training in 21 countries. The programme covers three types of training: 1. General techniques training: to develop skills in the use of some fundamental techniques in the field of nuclear energy; 2. Specialist training: to prepare specialists in the theoretical and experimental aspects of the science and technology of nuclear energy; 3. Research training: to provide advanced training, including active participation in research work; this is for persons potentially qualified to develop and carry out research programmes in the basic sciences and engineering. The duration of training varies from some weeks to five or six years. The long-duration training is given at universities or educational establishments of university level, and is of special interest to Member States lacking personnel with the requisite university education. Under its 1959 exchange and fellowship programme, the Agency will be in a position to award over 400 fellowships. Some of these will be paid out of the Agency's operating fund, while 130 fellowships have been offered directly to IAEA by Member States for training at their universities or institutes. There are two new features in the Agency's 1959 programme. One provides for fellowships for scientific research work, the other is the exchange of specialists

  6. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002...

  7. Conceptualizing Programme Evaluation

    Science.gov (United States)

    Hassan, Salochana

    2013-01-01

    The main thrust of this paper deals with the conceptualization of theory-driven evaluation pertaining to a tutor training programme. Conceptualization of evaluation, in this case, is an integration between a conceptualization model as well as a theoretical framework in the form of activity theory. Existing examples of frameworks of programme…

  8. The European Programme Manager

    DEFF Research Database (Denmark)

    Larson, Anne; Bergman, E.; Ehlers, S.

    The publication is a result of a cooperation between organisations in six European countries with the aim to develop a common European education for programme managers. It contains of a description of the different elements of the education together with a number of case-studies from the counties...

  9. The Productive Programmer

    CERN Document Server

    Ford, Neal

    2009-01-01

    Anyone who develops software for a living needs a proven way to produce it better, faster, and cheaper. The Productive Programmer offers critical timesaving and productivity tools that you can adopt right away, no matter what platform you use. Master developer Neal Ford details ten valuable practices that will help you elude common traps, improve your code, and become more valuable to your team.

  10. Scavenged body heat powered infusion pump

    International Nuclear Information System (INIS)

    Bell, Alexander; Ehringer, William D; McNamara, Shamus

    2013-01-01

    An infusion pump powered by body heat is investigated in this paper, with the goal of addressing the needs of dermal wound healing. The infusion pump incorporates a Knudsen gas pump, a type of thermally driven pump, to pneumatic push the pharmaceutical agent from a reservoir. Two designs are considered: an integrated pump and reservoir, and a design with cascaded pump and reservoir. Thermal models are developed for both pumps, and the simulations agree well with the experimental results. The integrated pump and reservoir design uses hydrophobic materials to prevent a flow from occurring unless the infusion pump is placed on a human body. Flow rates in the µL min −1 range for the integrated pump and reservoir, and approximately 70 µL min −1 for the cascaded pump were obtained. The dynamic behavior of the cascaded pump is described based on the thermal models. Multiple copies of the cascaded pump are easily made in series or parallel, to increase either the pressure or the flow rate. The flow rate of multiple pumps in series does not change, and the pressure of multiple pumps in parallel does not change. (paper)

  11. Vacuum pumping for controlled thermonuclear reactors

    International Nuclear Information System (INIS)

    Watson, J.S.; Fisher, P.W.

    1976-01-01

    Thermonuclear reactors impose unique vacuum pumping problems involving very high pumping speeds, handling of hazardous materials (tritium), extreme cleanliness requirements, and quantitative recovery of pumped materials. Two principal pumping systems are required for a fusion reactor, a main vacuum system for evacuating the torus and a vacuum system for removing unaccelerated deuterium from neutral beam injectors. The first system must pump hydrogen isotopes and helium while the neutral beam system can operate by pumping only hydrogen isotopes (perhaps only deuterium). The most promising pumping techniques for both systems appear to be cryopumps, but different cryopumping techniques can be considered for each system. The main vacuum system will have to include cryosorption pumps cooled to 4.2 0 K to pump helium, but the unburned deuterium-tritium and other impurities could be pumped with cryocondensation panels (4.2 0 K) or cryosorption panels at higher temperatures. Since pumping speeds will be limited by conductance through the ducts and thermal shields, the pumping performance for both systems will be similar, and other factors such as refrigeration costs are likely to determine the choice. The vacuum pumping system for neutral beam injectors probably will not need to pump helium, and either condensation or higher temperature sorption pumps can be used

  12. Conceptual study of the cryocascade for pumping, separation and recycling of ITER torus exhaust

    International Nuclear Information System (INIS)

    Mack, A.; Perinic, D.

    1994-01-01

    For pumping, separation and recycling of the ITER plasma exhaust, a pumping system working reliably under ambient and operating conditions of the ITER reactor is required. The pump is exposed to a magnetic field of about 3 T and has to be resistant to radioactive irradiation of 10 9 rad. In the burn and dwell phase, a gas mixture consisting of hydrogen isotopes, helium ash and impurities has to be pumped at the pressure range of 10 -2 - 10 -1 mbar. Within the framework of the European Fusion Technology Programme, the concept of a primary cryopump for use in ITER is being prepared at KfK. The cryocascade concept is planned to include three pump stages. These pump stages, which are connected in series, consist of individual chambers that may be separated from each other by means of cold valves. In the first stage, the impurities of the reactor exhaust gas are frozen out at 20-30 K. Settling of the hydrogen isotopes H/D/T on the 5 K cryosurfaces takes place in the second stage. This stage is made up of two parallel chambers, which can be switched from the pumping to the regeneration mode or vice versa. The helium fraction is bound in the downstream 5 K adsorption stage

  13. Detection of cavitation inception by acoustic technique in centrifugal pumps for nuclear application

    International Nuclear Information System (INIS)

    Prakash, V.; Prabhakar, R.; Rao, A.S.L.K.; Kale, R.D.

    1994-01-01

    The primary centrifugal pumps in a pool type reactor like the proposed Prototype Fast Breeder Reactor (PFBR) are required to operate at low values of available net positive suction head due to the limited submergence available in the pool. Pump hydraulics are designed to ensure that there is no cavitation or only minimum cavitation in the pump impeller in order to minimise long term erosion damage. Rigorous cavitation tests are usually carried out during development and final testing phase and a promising cavitation detection technique lies in acoustic noise measurements on the pump. As part of PFBR pump development programme, cavitation noise measurements were initially carried out on an experimental sodium pump in a water rig to establish detection procedures. Recently cavitation noise measurements were carried out on a 1/3 scale model impeller of PFBR pump along with visual observation of impeller passages to establish a correlation between visual and acoustic technique. Accelerometer responding to structure borne noise seems to give the best result. (author). 4 refs., 6 figs

  14. Pump Early, Pump Often: A Continuous Quality Improvement Project.

    Science.gov (United States)

    Spatz, Diane L; Froh, Elizabeth B; Schwarz, Jessica; Houng, Kathy; Brewster, Isabel; Myers, Carey; Prince, Judy; Olkkola, Michelle

    2015-01-01

    Research demonstrates that although many mothers initiate pumping for their critically ill children, few women are successful at maintaining milk supply throughout their infants' entire hospital stay. At the Garbose Family Special Delivery Unit (SDU) at the Children's Hospital of Philadelphia, we care for mothers who have critically ill infants born with complex cardiac and congenital anomalies. Human milk is viewed as a medical intervention at our institution. Therefore, nurses on the SDU wanted to ensure best practice in terms of pumping initiation. This article describes a continuous quality improvement project that ensured mothers pumped early and often. Childbirth educators can play a key role in preparing mothers who are anticipating an infant who will require hospitalization immediately post-birth.

  15. ADS National Programmes: China

    International Nuclear Information System (INIS)

    2015-01-01

    In China the conceptual study of an ADS concept which lasted for about five years ended in 1999. As one project of the National Basic Research Programme of China (973 Programme) in energy domain, which is sponsored by the China Ministry of Science and Technology (MOST), a five year programme of fundamental research of ADS physics and related technology was launched in 2000 and passed national review at the end of 2005. From 2007, another five year 973 Programme Key Technology Research of Accelerator Driven Subcritical System for Nuclear waste Transmutation started. The research activities were focused on HPPA physics and technology, reactor physics of external source driven subcritical assembly, nuclear data base and material study. For HPPA, a high current injector consisting of an ECR ion source, LEBT and an RFQ accelerating structure of 3.5 MeV has been built and were being improved. In reactor physics study, a series of neutron multiplication experimental study has been carrying out. The VENUS I facility has been constructed as the basic experimental platform for neutronics study in ADS blanket. VENUS I a zero power subcritical neutron multiplying assembly driven by external neutron produced by a pulsed neutron generator or 252Cf neutron source. The theoretical, experimental and simulation studies on nuclear data, material properties and nuclear fuel circulation related to ADS are carried out in order to provide the database for ADS system analysis. China Institute of Atomic Energy (CIAE), Institute of High Energy Physics (IHEP) and other Chinese institutes carried out the MOST project together. Besides CIAE, China Academy of Science (CAS) pays more and more attention to Advanced Nuclear Fuel Cycles (ANFC). A large programme of ANFC, including ADS and Th based nuclear fuel cycle, has been launched by CAS

  16. Reactor feedwater pump control device

    International Nuclear Information System (INIS)

    Nishiyama, Hiroyuki.

    1990-01-01

    An amount of feedwater necessary for ensuring reactor inventory after scram is ensured automatically based on the reactor output before scram of a BWR type reactor. That is, if scram should occur, a feedwater flow rate just before the scram is stored by reactor output signals. Further, the amount of feedwater required after the scram is determined based on the output of the memory. The reactor power after the scram based on a feedwater flow rate and a main steam flow rate is inputted to an integrator, to calculate and output the amount of the feedwater flow rate (1) injected after the scram for the inventory. A coast down flowrate (2) in a case of pump trip is forecast by the output signals. Automatic trip is outputted to all turbine driving feedwater pumps when the sum of (1) and (2) exceeds a necessary and sufficient amount of feedwater required for ensuring inventory. For motor driving feedwater pumps, only a portion, for example, one of the pumps is automatically started while other pumps are stopped their operation, only in this case, to prevent excess water feeding. (I.S.)

  17. The lunar thermal ice pump

    Energy Technology Data Exchange (ETDEWEB)

    Schorghofer, Norbert [Institute for Astronomy and NASA Astrobiology Institute, University of Hawaii, Honolulu, HI 96822 (United States); Aharonson, Oded, E-mail: norbert@hawaii.edu [Helen Kimmel Center for Planetary Science, Department of Earth and Planetary Sciences, Weizmann Institute of Science, Rehovot, 76100 (Israel)

    2014-06-20

    It has long been suggested that water ice can exist in extremely cold regions near the lunar poles, where sublimation loss is negligible. The geographic distribution of H-bearing regolith shows only a partial or ambiguous correlation with permanently shadowed areas, thus suggesting that another mechanism may contribute to locally enhancing water concentrations. We show that under suitable conditions, water molecules can be pumped down into the regolith by day-night temperature cycles, leading to an enrichment of H{sub 2}O in excess of the surface concentration. Ideal conditions for pumping are estimated and found to occur where the mean surface temperature is below 105 K and the peak surface temperature is above 120 K. These conditions complement those of the classical cold traps that are roughly defined by peak temperatures lower than 120 K. On the present-day Moon, an estimated 0.8% of the global surface area experiences such temperature variations. Typically, pumping occurs on pole-facing slopes in small areas, but within a few degrees of each pole the equator-facing slopes are preferred. Although pumping of water molecules is expected over cumulatively large areas, the absolute yield of this pump is low; at best, a few percent of the H{sub 2}O delivered to the surface could have accumulated in the near-surface layer in this way. The amount of ice increases with vapor diffusivity and is thus higher in the regolith with large pore spaces.

  18. Heat pumps in western Switzerland

    International Nuclear Information System (INIS)

    Freymond, A.

    2003-01-01

    The past ten years have seen an extraordinary expansion of heat-pump market figures in the western (French speaking) part of Switzerland. Today, more than 14,000 units are in operation. This corresponds to about 18% of all the machines installed in the whole country, compared to only 10 to 12% ten years ago. This success illustrates the considerable know-how accumulated by the leading trade and industry during these years. It is also due to the promotional program 'Energy 2000' of the Swiss Federal Department of Energy that included the heat pump as a renewable energy source. Already in 1986, the Swiss Federal Institute of Technology in Lausanne was equipped with a huge heat pump system comprising two electrically driven heat pumps of 3.5 MW thermal power each. The heat source is water drawn from the lake of Geneva at a depth of 70 meters. An annual coefficient of performance of 4.5 has been obtained since the commissioning of the plant. However, most heat pump installations are located in single-family dwellings. The preferred heat source is geothermal heat, using borehole heat exchangers and an intermediate heat transfer fluid. The average coefficient of performance of these installations has been increased from 2.5 in 1995 to 3.1 in 2002

  19. Operating pumps on minimum flow

    International Nuclear Information System (INIS)

    Casada, D.A.; Li, Y.C.

    1992-01-01

    The Nuclear Regulatory Commission (NRC) staff issued Information Notice (IN) 87-59 to alert all licensees to two miniflow design concerns identified by Westinghouse. The first potential problem discussed in this IN involves parallel pump operation. If the head/capacity curve of one of the parallel pumps is greater than the other, the weaker pump may be dead-headed when the pumps are operating at low-flow conditions. The other problem related to potential pump damage as a result of hydraulic instability during low-flow operation. In NRC Bulletin 88-04, dated May 5, 1988, the staff requested all licensees to investigate and correct, as applicable, the two miniflow design concerns. The staff also developed a Temporary Instruction, Tl 2515/105, dated January 29, 1990 to inspect for the adequacy of licensee response and follow-up actions to NRC Bulletin 88-04. Oak Ridge National Laboratory has reviewed utility responses to Bulletin 88-04 under auspices of the NRC's Nuclear Plant Aging Research Program, and participated in several NRC inspections. Examples of actions that have been taken, an assessment of the overall industry response, and resultant conclusions and recommendations are presented

  20. Microelectromechanical pump utilizing porous silicon

    Science.gov (United States)

    Lantz, Jeffrey W [Albuquerque, NM; Stalford, Harold L [Norman, OK

    2011-07-19

    A microelectromechanical (MEM) pump is disclosed which includes a porous silicon region sandwiched between an inlet chamber and an outlet chamber. The porous silicon region is formed in a silicon substrate and contains a number of pores extending between the inlet and outlet chambers, with each pore having a cross-section dimension about equal to or smaller than a mean free path of a gas being pumped. A thermal gradient is provided along the length of each pore by a heat source which can be an electrical resistance heater or an integrated circuit (IC). A channel can be formed through the silicon substrate so that inlet and outlet ports can be formed on the same side of the substrate, or so that multiple MEM pumps can be connected in series to form a multi-stage MEM pump. The MEM pump has applications for use in gas-phase MEM chemical analysis systems, and can also be used for passive cooling of ICs.